1
|
Makhneva E, Špaček P, Hlaváček A, Weisová J, Gorris HH, Skládal P, Farka Z. Bioconjugates of photon-upconversion nanoparticles with antibodies for the detection of prostate-specific antigen and p53 in heterogeneous and homogeneous immunoassays. NANOSCALE 2025; 17:11401-11412. [PMID: 40231544 DOI: 10.1039/d5nr00176e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/16/2025]
Abstract
Sensitive immunoassays for the detection of tumor biomarkers play an important role in the early diagnosis and therapy of cancer. Using luminescent nanomaterials as labels can significantly improve immunoassay performance, especially in terms of sensitivity. Lanthanide-doped photon-upconversion nanoparticles (UCNPs) are nanocrystals capable of converting near-infrared radiation into visible light, and their emission spectra can be tuned by altering the dopant ions. In this study, the bioconjugation between UCNPs and biomolecules was optimized, and different conjugates of Er- and Tm-doped UCNPs (NaYF4:Yb3+,Er3+ and NaYF4:Yb3+,Tm3+) were prepared for detecting prostate-specific antigen (PSA) and tumor protein p53, comparing heterogeneous and homogeneous assay formats. The heterogeneous sandwich immunoassay achieved detection limits of 1.3 pg mL-1 for PSA and 330 pg mL-1 for p53. The homogeneous immunoassays were based on massively parallel spectroscopy (MPS), a novel artificial intelligence-aided single-molecule approach, utilizing conjugates of two different monoclonal antibodies with Er- and Tm-doped UCNPs, respectively. The conjugates provide distinct emission spectra, with only sandwich immunocomplexes of analytes and both types of labels showing signals at the same location. MPS was suitable for observing the immunocomplexes in an aqueous dispersion using only a small sample volume. This innovative method achieved detection limits of 8.2 ng mL-1 and 390 pg mL-1 for PSA and p53, respectively. MPS eliminates the need for time-consuming washing steps required in heterogeneous immunoassays and is amenable to high-throughput applications.
Collapse
Affiliation(s)
- Ekaterina Makhneva
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.
| | - Pavel Špaček
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.
| | - Antonín Hlaváček
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 967/97, 602 00 Brno, Czech Republic.
| | - Julie Weisová
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 967/97, 602 00 Brno, Czech Republic.
| | - Hans H Gorris
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.
| | - Petr Skládal
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.
| | - Zdeněk Farka
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.
| |
Collapse
|
2
|
Wang Q, Zhao ZA, Yao KY, Cheng YL, Wong DSH, Wong DWC, Cheung JCW. The Versatility of Biological Field-Effect Transistor-Based Biosensors (BioFETs) in Point-of-Care Diagnostics: Applications and Future Directions for Peritoneal Dialysis Monitoring. BIOSENSORS 2025; 15:193. [PMID: 40136991 PMCID: PMC11940136 DOI: 10.3390/bios15030193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/17/2025] [Revised: 03/10/2025] [Accepted: 03/16/2025] [Indexed: 03/27/2025]
Abstract
Peritoneal dialysis (PD) is a vital treatment for end-stage renal disease patients, but its efficacy is often compromised by complications such as infections and peritoneal fibrosis. Biological field-effect transistors (BioFETs) present a promising solution for rapid, sensitive, and non-invasive detection of indicators and biomarkers associated with these complications, potentially enabling early intervention. However, BioFETs are yet to be adopted for PD monitoring. This review presents a forward-looking analysis of the capacity and potential integration of BioFETs into PD management systems, highlighting their capacity to monitor both routine indicators of dialysis efficiency and metabolic status, as well as specific biomarkers for complications such as inflammation and fibrosis. We examine the challenges in adapting BioFETs for PD applications, focusing on key areas for improvement, including sensitivity, specificity, stability, reusability, and clinical integration. Furthermore, we discuss various approaches to address these challenges, which are crucial for developing point-of-care (PoC) and multiplexed wearable devices. These advancements could facilitate continuous, precise, and user-friendly monitoring, potentially revolutionizing PD complication management and enhancing patient care.
Collapse
Affiliation(s)
- Quan Wang
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
| | - Zi-An Zhao
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
| | - Ke-Yu Yao
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
| | - Yuk-Lun Cheng
- Department of Medicine, Alice Ho Miu Ling Nethersole Hospital, Hong Kong
| | - Dexter Siu-Hong Wong
- School of Medicine and Pharmacy, Ocean University of China, Qingdao 266003, China
| | - Duo Wai-Chi Wong
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
| | - James Chung-Wai Cheung
- Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Hong Kong
- Research Institute for Smart Ageing, The Hong Kong Polytechnic University, Hong Kong
| |
Collapse
|
3
|
Albarghouthi FM, Semeniak D, Khanani I, Doherty JL, Smith BN, Salfity M, MacFarlane Q, Karappur A, Noyce SG, Williams NX, Joh DY, Andrews JB, Chilkoti A, Franklin AD. Addressing Signal Drift and Screening for Detection of Biomarkers with Carbon Nanotube Transistors. ACS NANO 2024. [PMID: 38335120 DOI: 10.1021/acsnano.3c11679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/12/2024]
Abstract
Electrical biosensors, including transistor-based devices (i.e., BioFETs), have the potential to offer versatile biomarker detection in a simple, low-cost, scalable, and point-of-care manner. Semiconducting carbon nanotubes (CNTs) are among the most explored nanomaterial candidates for BioFETs due to their high electrical sensitivity and compatibility with diverse fabrication approaches. However, when operating in solutions at biologically relevant ionic strengths, CNT-based BioFETs suffer from debilitating levels of signal drift and charge screening, which are often unaccounted for or sidestepped (but not addressed) by testing in diluted solutions. In this work, we present an ultrasensitive CNT-based BioFET called the D4-TFT, an immunoassay with an electrical readout, which overcomes charge screening and drift-related limitations of BioFETs. In high ionic strength solution (1X PBS), the D4-TFT repeatedly and stably detects subfemtomolar biomarker concentrations in a point-of-care form factor by increasing the sensing distance in solution (Debye length) and mitigating signal drift effects. Debye length screening and biofouling effects are overcome using a poly(ethylene glycol)-like polymer brush interface (POEGMA) above the device into which antibodies are printed. Simultaneous testing of a control device having no antibodies printed over the CNT channel confirms successful detection of the target biomarker via an on-current shift caused by antibody sandwich formation. Drift in the target signal is mitigated by a combination of: (1) maximizing sensitivity by appropriate passivation alongside the polymer brush coating; (2) using a stable electrical testing configuration; and (3) enforcing a rigorous testing methodology that relies on infrequent DC sweeps rather than static or AC measurements. These improvements are realized in a relatively simple device using printed CNTs and antibodies for a low-cost, versatile platform for the ongoing pursuit of point-of-care BioFETs.
Collapse
Affiliation(s)
- Faris M Albarghouthi
- Department of Electrical & Computer Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Daria Semeniak
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Iman Khanani
- Department of Electrical & Computer Engineering, Duke University, Durham, North Carolina 27708, United States
| | - James L Doherty
- Department of Electrical & Computer Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Brittany N Smith
- Department of Electrical & Computer Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Matthew Salfity
- Department of Electrical & Computer Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Quentin MacFarlane
- Department of Electrical & Computer Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Aneesh Karappur
- Department of Electrical & Computer Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Steven G Noyce
- Department of Electrical & Computer Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Nicholas X Williams
- Department of Electrical & Computer Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Daniel Y Joh
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Joseph B Andrews
- Department of Electrical & Computer Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Ashutosh Chilkoti
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708, United States
| | - Aaron D Franklin
- Department of Electrical & Computer Engineering, Duke University, Durham, North Carolina 27708, United States
- Department of Chemistry, Duke University, Durham, North Carolina 27708, United States
| |
Collapse
|
4
|
Lavecchia di Tocco F, Botti V, Cannistraro S, Bizzarri AR. Detection of miR-155 Using Peptide Nucleic Acid at Physiological-like Conditions by Surface Plasmon Resonance and Bio-Field Effect Transistor. BIOSENSORS 2024; 14:79. [PMID: 38391998 PMCID: PMC10887097 DOI: 10.3390/bios14020079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 01/21/2024] [Accepted: 01/30/2024] [Indexed: 02/24/2024]
Abstract
MicroRNAs are small ribonucleotides that act as key gene regulators. Their altered expression is often associated with the onset and progression of several human diseases, including cancer. Given their potential use as biomarkers, there is a need to find detection methods for microRNAs suitable for use in clinical setting. Field-effect-transistor-based biosensors (bioFETs) appear to be valid tools to detect microRNAs, since they may reliably quantitate the specific binding between the immobilized probe and free target in solution through an easily detectable electrical signal. We have investigated the detection of human microRNA 155 (miR-155) using an innovative capturing probe constituted by a synthetic peptide nucleic acid (PNA), which has the advantage to form a duplex even at ionic strengths approaching the physiological conditions. With the aim to develop an optimized BioFET setup, the interaction kinetics between miR-155 and the chosen PNA was preliminarily investigated by using surface plasmon resonance (SPR). By exploiting both these results and our custom-made bioFET system, we were able to attain a low-cost, real-time, label-free and highly specific detection of miR-155 in the nano-molar range.
Collapse
Affiliation(s)
| | | | | | - Anna Rita Bizzarri
- Biophysics and Nanoscience Centre, DEB, Università della Tuscia, Largo dell’Università, 01100 Viterbo, Italy; (F.L.d.T.); (V.B.); (S.C.)
| |
Collapse
|
5
|
Jeong S, Son SU, Kim J, Cho SI, Kang T, Kim S, Lim EK, Ko Park SH. Rapid and simultaneous multiple detection of a tripledemic using a dual-gate oxide semiconductor thin-film transistor-based immunosensor. Biosens Bioelectron 2023; 241:115700. [PMID: 37757509 DOI: 10.1016/j.bios.2023.115700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 08/22/2023] [Accepted: 09/19/2023] [Indexed: 09/29/2023]
Abstract
The simultaneous infection with a tripledemic-simultaneous infection with influenza A pH1N1 virus (Flu), severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), and respiratory syncytial virus (RSV)-necessitates the development of accurate and fast multiplex diagnostic tests. The coronavirus disease 2019 (COVID-19) pandemic has emphasized the importance of virus detection. Field-effect transistor (FET)-based immuno-biosensors have a short detection time and do not require labeling or polymerase chain reaction. This study demonstrates the rapid, sensitive detection of influenza A pH1N1, SARS-CoV-2, and RSV using a multiplex immunosensor based on a dual-gate oxide semiconductor thin-film transistor (TFT), a type of FET. The dual-gate oxide TFT was modified by adjusting both top and bottom gate insulators to improve capacitive coupling to approximately 120-fold amplification, exhibiting a high pH sensitivity of about 10 V/pH. The dual-gate oxide TFT-based immunosensor detected the target proteins (hemagglutinin (HA) protein of Flu, spike 1 (S1) protein of SARS-CoV-2, and fusion protein of RSV) of each virus, with a limit of detection of approximately 1 fg/mL. Cultured viruses in phosphate-buffered saline or artificial saliva and clinical nasopharynx samples were detected in 1-μL sample volumes within 60 s. This promising diagnosis could be potentially as point-of-care tests to facilitate a prompt response to future pandemics with high sensitivity and multiplexed detection without pretreatment.
Collapse
Affiliation(s)
- Sehun Jeong
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Seong Uk Son
- BioNanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology, 125 Gwahak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea; Department of Nanobiotechnology, Korea Research Institute of Bioscience and Biotechnology, School of Biotechnology, University of Science and Technology (UST), 217 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea
| | - Jingyu Kim
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Seong-In Cho
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea
| | - Taejoon Kang
- BioNanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology, 125 Gwahak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea; School of Pharmacy, Sungkyunkwan University, Suwon, 16419, Republic of Korea
| | - Sunjoo Kim
- Department of Laboratory Medicine, Gyeongsang National University Changwon Hospital, Changwon, 51472, Republic of Korea; Gyeongnam Center for Infectious Disease Control and Prevention, Changwon, 51154, Republic of Korea; Gyeongsang National University College of Medicine, Gyeongsang Institute of Health Sciences, Jinju, 52727, Republic of Korea
| | - Eun-Kyung Lim
- BioNanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology, 125 Gwahak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea; Department of Nanobiotechnology, Korea Research Institute of Bioscience and Biotechnology, School of Biotechnology, University of Science and Technology (UST), 217 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea; School of Pharmacy, Sungkyunkwan University, Suwon, 16419, Republic of Korea.
| | - Sang-Hee Ko Park
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141, Republic of Korea.
| |
Collapse
|
6
|
Janićijević Ž, Nguyen-Le TA, Alsadig A, Cela I, Žilėnaite R, Tonmoy TH, Kubeil M, Bachmann M, Baraban L. Methods gold standard in clinic millifluidics multiplexed extended gate field-effect transistor biosensor with gold nanoantennae as signal amplifiers. Biosens Bioelectron 2023; 241:115701. [PMID: 37757510 DOI: 10.1016/j.bios.2023.115701] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 08/30/2023] [Accepted: 09/20/2023] [Indexed: 09/29/2023]
Abstract
We present a portable multiplexed biosensor platform based on the extended gate field-effect transistor and demonstrate its amplified response thanks to gold nanoparticle-based bioconjugates introduced as a part of the immunoassay. The platform comprises a disposable chip hosting an array of 32 extended gate electrodes, a readout module based on a single transistor operating in constant charge mode, and a multiplexer to scan sensing electrodes one-by-one. Although employing only off-the-shelf electronic components, our platform achieves sensitivities comparable to fully customized nanofabricated potentiometric sensors. In particular, it reaches a detection limit of 0.2 fM for the pure molecular assay when sensing horseradish peroxidase-linked secondary antibody (∼0.4 nM reached by standard microplate methods). Furthermore, with the gold nanoparticle bioconjugation format, we demonstrate ca. 5-fold amplification of the potentiometric response compared to a pure molecular assay, at the detection limit of 13.3 fM. Finally, we elaborate on the mechanism of this amplification and propose that nanoparticle-mediated disruption of the diffusion barrier layer is the main contributor to the potentiometric signal enhancement. These results show the great potential of our portable, sensitive, and cost-efficient biosensor for multidimensional diagnostics in the clinical and laboratory settings, including e.g., serological tests or pathogen screening.
Collapse
Affiliation(s)
- Željko Janićijević
- Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328, Dresden, Germany
| | - Trang-Anh Nguyen-Le
- Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328, Dresden, Germany
| | - Ahmed Alsadig
- Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328, Dresden, Germany
| | - Isli Cela
- Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328, Dresden, Germany
| | - Rugilė Žilėnaite
- Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328, Dresden, Germany; Faculty of Chemistry and Geosciences, Institute of Chemistry, Vilnius University, Naugarduko g. 24, LT-03225, Vilnius, Lithuania
| | - Taufhik Hossain Tonmoy
- Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328, Dresden, Germany
| | - Manja Kubeil
- Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328, Dresden, Germany
| | - Michael Bachmann
- Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328, Dresden, Germany
| | - Larysa Baraban
- Institute of Radiopharmaceutical Cancer Research, Helmholtz-Zentrum Dresden-Rossendorf, Bautzner Landstraße 400, 01328, Dresden, Germany.
| |
Collapse
|
7
|
Rabbani G, Khan ME, Ahmad E, Khan MV, Ahmad A, Khan AU, Ali W, Zamzami MA, Bashiri AH, Zakri W. Serum CRP biomarker detection by using carbon nanotube field-effect transistor (CNT-FET) immunosensor. Bioelectrochemistry 2023; 153:108493. [PMID: 37392576 DOI: 10.1016/j.bioelechem.2023.108493] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Revised: 06/18/2023] [Accepted: 06/19/2023] [Indexed: 07/03/2023]
Abstract
C-reactive protein (CRP) is produced by the liver in response to systemic inflammation caused by bacterial infection, trauma and internal organ failures. CRP serves as a potential biomarker in the precise diagnosis of cardiovascular risk, type-2 diabetes, metabolic syndrome, hypertension and various types of cancers. The pathogenic conditions indicated above are diagnosed by an elevated CRP level in the serum. In this study, we successfully fabricated a highly sensitive and selective carbon nanotube field-effect transistor (CNT-FET) immunosensor for the detection of CRP. The CNTs were deposited on the Si/SiO2 surface, between source-drain electrodes, afterwards modified with well-known linker PBASE and then anti-CRP was immobilized. This anti-CRP functionalized CNT-FET immunosensor exhibits a wide dynamic detection range (0.01-1000 μg/mL) CRP detection, rapid response time (2-3 min) and low variation (<3 %) which can be delivered as a low-cost and rapid clinical detection technology for the early diagnosis of coronary heart disease (CHD). For the clinical applications, our sensor was tested using CRP fortified serum samples and sensing performance was validated using enzyme-linked immune-sorbent assay (ELISA). This CNT-FET immunosensor will be helpful in taking over the complex laboratory-based expensive traditional CRP diagnostic procedures practiced in the hospitals.
Collapse
Affiliation(s)
- Gulam Rabbani
- IT-medical Fusion Center, 350-27 Gumidae-ro, Gumi-si, Gyeongbuk 39253, Republic of Korea
| | - Mohammad Ehtisham Khan
- Department of Chemical Engineering Technology, College of Applied Industrial Technology, Jazan University, 45142, Saudi Arabia.
| | - Ejaz Ahmad
- Department of Pathology, University of Michigan Medical School, Ann Arbor, MI 48109, USA
| | - Mohsin Vahid Khan
- Department of Biosciences, Integral University, Lucknow 226026, India
| | - Abrar Ahmad
- Department of Biochemistry, Faculty of Science, King Abdulaziz University, Jeddah 21452, Saudi Arabia
| | - Anwar Ulla Khan
- Department of Electrical Engineering Technology, College of Applied Industrial Technology, Jazan University, 45142, Saudi Arabia
| | - Wahid Ali
- Department of Chemical Engineering Technology, College of Applied Industrial Technology, Jazan University, 45142, Saudi Arabia
| | - Mazin A Zamzami
- Department of Biochemistry, Faculty of Science, King Abdulaziz University, Jeddah 21452, Saudi Arabia
| | - Abdullateef H Bashiri
- Department of Mechanical Engineering, College of Engineering, Jazan University, P. O. Box 114, Jazan 45142, Saudi Arabia
| | - Waleed Zakri
- Department of Mechanical Engineering, College of Engineering, Jazan University, P. O. Box 114, Jazan 45142, Saudi Arabia
| |
Collapse
|
8
|
Wu Q, Hou Q, Wang P, Ding C, Lv S. Antifouling Electrochemiluminescence Biosensor Based on Bovine Serum Albumin Hydrogel for the Accurate Detection of p53 Gene in Human Serum. ACS APPLIED MATERIALS & INTERFACES 2023; 15:44322-44330. [PMID: 37672622 DOI: 10.1021/acsami.3c09737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/08/2023]
Abstract
To detect biomarkers in complex samples, it is fundamental to avoid the nonspecific adsorption of impurities to improve the selectivity of biosensors. In this study, a sensitive antifouling electrochemiluminescence biosensor was proposed based on bovine serum albumin (BSA)- and exonuclease III (Exo III)-mediated nucleic acid cycle signal amplification strategy. Ti3C2Tx-NH4, which has a large surface area and high metal conductivity, was crosslinked with BSA to improve the conductivity of the sensing interface, which shows antifouling performance excellently due to the electrical neutrality and good hydrophilicity of BSA hydrogel. The cyclic amplification strategy based on Exo III and DNA hybridization chain reaction significantly amplified the electrochemiluminescence signal and improved the sensitivity of p53 gene detection. The linear range of the biosensor is 1 fM-1 nM with a detection limit of 0.26 fM. More importantly, the sensor showed excellent selectivity when it was used to detect the p53 gene in real samples, such as serum. Thus, this unique antifouling sensing interface is expected to construct various electrochemical biosensors in clinical diagnosis and biopathological analysis.
Collapse
Affiliation(s)
- Qiongwei Wu
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education; Shandong Key Laboratory of Biochemical Analysis; Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, PR China
| | - Qianqian Hou
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education; Shandong Key Laboratory of Biochemical Analysis; Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, PR China
| | - Peipei Wang
- Department of Rehabilitation Medicine, Affiliated Qingdao Central Hospital of Qingdao University, Qingdao Cancer Hospital, Qingdao 266042, China
| | - Caifeng Ding
- Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education; Shandong Key Laboratory of Biochemical Analysis; Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong; College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, PR China
- Department of Rehabilitation Medicine, Affiliated Qingdao Central Hospital of Qingdao University, Qingdao Cancer Hospital, Qingdao 266042, China
| | - Shaoping Lv
- Department of Rehabilitation Medicine, Affiliated Qingdao Central Hospital of Qingdao University, Qingdao Cancer Hospital, Qingdao 266042, China
| |
Collapse
|
9
|
Rahn KL, Peramune U, Zhang T, Anand RK. Label-Free Electrochemical Methods for Disease Detection. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY (PALO ALTO, CALIF.) 2023; 16:49-69. [PMID: 36854209 DOI: 10.1146/annurev-anchem-091622-085754] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Label-free electrochemical biosensing leverages the advantages of label-free techniques, low cost, and fewer user steps, with the sensitivity and portability of electrochemical analysis. In this review, we identify four label-free electrochemical biosensing mechanisms: (a) blocking the electrode surface, (b) allowing greater access to the electrode surface, (c) changing the intercalation or electrostatic affinity of a redox probe to a biorecognition unit, and (d) modulating ion or electron transport properties due to conformational and surface charge changes. Each mechanism is described, recent advancements are summarized, and relative advantages and disadvantages of the techniques are discussed. Furthermore, two avenues for gaining further diagnostic information from label-free electrochemical biosensors, through multiplex analysis and incorporating machine learning, are examined.
Collapse
Affiliation(s)
- Kira L Rahn
- Department of Chemistry, Colorado State University, Fort Collins, Colorado, USA
- Department of Chemistry, Iowa State University, Ames, Iowa, USA;
| | - Umesha Peramune
- Department of Chemistry, Iowa State University, Ames, Iowa, USA;
| | - Tianyi Zhang
- Department of Chemistry, Iowa State University, Ames, Iowa, USA;
| | - Robbyn K Anand
- Department of Chemistry, Iowa State University, Ames, Iowa, USA;
| |
Collapse
|
10
|
Sequeira-Antunes B, Ferreira HA. Urinary Biomarkers and Point-of-Care Urinalysis Devices for Early Diagnosis and Management of Disease: A Review. Biomedicines 2023; 11:biomedicines11041051. [PMID: 37189669 DOI: 10.3390/biomedicines11041051] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2023] [Revised: 03/10/2023] [Accepted: 03/27/2023] [Indexed: 03/31/2023] Open
Abstract
Biosensing and microfluidics technologies are transforming diagnostic medicine by accurately detecting biomolecules in biological samples. Urine is a promising biological fluid for diagnostics due to its noninvasive collection and wide range of diagnostic biomarkers. Point-of-care urinalysis, which integrates biosensing and microfluidics, has the potential to bring affordable and rapid diagnostics into the home to continuing monitoring, but challenges still remain. As such, this review aims to provide an overview of biomarkers that are or could be used to diagnose and monitor diseases, including cancer, cardiovascular diseases, kidney diseases, and neurodegenerative disorders, such as Alzheimer’s disease. Additionally, the different materials and techniques for the fabrication of microfluidic structures along with the biosensing technologies often used to detect and quantify biological molecules and organisms are reviewed. Ultimately, this review discusses the current state of point-of-care urinalysis devices and highlights the potential of these technologies to improve patient outcomes. Traditional point-of-care urinalysis devices require the manual collection of urine, which may be unpleasant, cumbersome, or prone to errors. To overcome this issue, the toilet itself can be used as an alternative specimen collection and urinalysis device. This review then presents several smart toilet systems and incorporated sanitary devices for this purpose.
Collapse
|
11
|
Parmeggiani M, Ballesio A, Battistoni S, Carcione R, Cocuzza M, D’Angelo P, Erokhin VV, Marasso SL, Rinaldi G, Tarabella G, Vurro D, Pirri CF. Organic Bioelectronics Development in Italy: A Review. MICROMACHINES 2023; 14:460. [PMID: 36838160 PMCID: PMC9966652 DOI: 10.3390/mi14020460] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Revised: 02/06/2023] [Accepted: 02/10/2023] [Indexed: 06/18/2023]
Abstract
In recent years, studies concerning Organic Bioelectronics have had a constant growth due to the interest in disciplines such as medicine, biology and food safety in connecting the digital world with the biological one. Specific interests can be found in organic neuromorphic devices and organic transistor sensors, which are rapidly growing due to their low cost, high sensitivity and biocompatibility. This trend is evident in the literature produced in Italy, which is full of breakthrough papers concerning organic transistors-based sensors and organic neuromorphic devices. Therefore, this review focuses on analyzing the Italian production in this field, its trend and possible future evolutions.
Collapse
Affiliation(s)
- Matteo Parmeggiani
- Chilab–Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d’Armi 6, 10034 Turin, Italy
| | - Alberto Ballesio
- Chilab–Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d’Armi 6, 10034 Turin, Italy
| | - Silvia Battistoni
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Rocco Carcione
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Matteo Cocuzza
- Chilab–Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d’Armi 6, 10034 Turin, Italy
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Pasquale D’Angelo
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Victor V. Erokhin
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Simone Luigi Marasso
- Chilab–Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d’Armi 6, 10034 Turin, Italy
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Giorgia Rinaldi
- Chilab–Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d’Armi 6, 10034 Turin, Italy
| | - Giuseppe Tarabella
- Institute of Materials for Electronics and Magnetism, IMEM-CNR, Parco Area delle Scienze 37/A, 43124 Parma, Italy
| | - Davide Vurro
- Camlin Italy Srl, Via Budellungo 2, 43124 Parma, Italy
| | - Candido Fabrizio Pirri
- Chilab–Materials and Microsystems Laboratory, Department of Applied Science and Technology (DISAT), Politecnico di Torino, Via Lungo Piazza d’Armi 6, 10034 Turin, Italy
- Center for Sustainable Future Technologies, Italian Institute of Technology, Via Livorno 60, 10144 Turin, Italy
| |
Collapse
|
12
|
Lu HW, Kane AA, Parkinson J, Gao Y, Hajian R, Heltzen M, Goldsmith B, Aran K. The promise of graphene-based transistors for democratizing multiomics studies. Biosens Bioelectron 2022; 195:113605. [PMID: 34537553 DOI: 10.1016/j.bios.2021.113605] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 07/22/2021] [Accepted: 08/29/2021] [Indexed: 12/28/2022]
Abstract
As biological research has synthesized genomics, proteomics, metabolomics, and transcriptomics into systems biology, a new multiomics approach to biological research has emerged. Today, multiomics studies are challenging and expensive. An experimental platform that could unify the multiple omics approaches to measurement could increase access to multiomics data by enabling more individual labs to successfully attempt multiomics studies. Field effect biosensing based on graphene transistors have gained significant attention as a potential unifying technology for such multiomics studies. This review article highlights the outstanding performance characteristics that makes graphene field effect transistor an attractive sensing platform for a wide variety of analytes important to system biology. In addition to many studies demonstrating the biosensing capabilities of graphene field effect transistors, they are uniquely suited to address the challenges of multiomics studies by providing an integrative multiplex platform for large scale manufacturing using the well-established processes of semiconductor industry. Furthermore, the resulting digital data is readily analyzable by machine learning to derive actionable biological insight to address the challenge of data compatibility for multiomics studies. A critical stage of systems biology will be democratizing multiomics study, and the graphene field effect transistor is uniquely positioned to serve as an accessible multiomics platform.
Collapse
Affiliation(s)
- Hsiang-Wei Lu
- Keck Graduate Institute, The Claremont Colleges, Claremont, CA, 91711, USA; Cardea Bio, San Diego, CA, 92121, USA
| | | | | | | | - Reza Hajian
- Keck Graduate Institute, The Claremont Colleges, Claremont, CA, 91711, USA; Cardea Bio, San Diego, CA, 92121, USA
| | | | | | - Kiana Aran
- Keck Graduate Institute, The Claremont Colleges, Claremont, CA, 91711, USA; Cardea Bio, San Diego, CA, 92121, USA.
| |
Collapse
|
13
|
Ma Y, Qiang T, Gao M, Liang J, Jiang Y. Quantitative, Temperature-Calibrated and Real-Time Glucose Biosensor Based on Symmetrical-Meandering-Type Resistor and Intertwined Capacitor Structure. BIOSENSORS 2021; 11:484. [PMID: 34940241 PMCID: PMC8699495 DOI: 10.3390/bios11120484] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/10/2021] [Revised: 11/25/2021] [Accepted: 11/26/2021] [Indexed: 11/17/2022]
Abstract
Here, we propose a glucose biosensor with the advantages of quantification, excellent linearity, temperature-calibration function, and real-time detection based on a resistor and capacitor, in which the resistor works as a temperature sensor and the capacitor works as a biosensor. The resistor has a symmetrical meandering type structure that increases the contact area, leading to variations in resistance and effective temperature monitoring of a glucose solution. The capacitor is designed with an intertwined structure that fully contacts the glucose solution, so that capacitance is sensitively varied, and high sensitivity monitoring can be realized. Moreover, a polydimethylsiloxane microfluidic channel is applied to achieve a fixed shape, a fixed point, and quantitative measurements, which can eliminate influences caused by fluidity, shape, and thickness of the glucose sample. The glucose solution in a temperature range of 25-100 °C is measured with variations of 0.2716 Ω/°C and a linearity response of 0.9993, ensuring that the capacitor sensor can have reference temperature information before detecting the glucose concentration, achieving the purpose of temperature calibration. The proposed capacitor-based biosensor demonstrates sensitivities of 0.413 nF/mg·dL-1, 0.048 nF/mg·dL-1, and 0.011 pF/mg·dL-1; linearity responses of 0.96039, 0.91547, and 0.97835; and response times less than 1 second, respectively, at DC, 1 kHz, and 1 MHz for a glucose solution with a concentration range of 25-1000 mg/dL.
Collapse
Affiliation(s)
| | - Tian Qiang
- Department of Electronic Engineering, School of Internet of Things Engineering, Jiangnan University, Wuxi 214122, China; (Y.M.); (M.G.); (J.L.); (Y.J.)
| | | | | | | |
Collapse
|
14
|
Halima HB, Errachid A, Jaffrezic‐Renault N. Electrochemical Affinity Sensors Using Field Effect Transducer Devices for Chemical Analysis. ELECTROANAL 2021. [DOI: 10.1002/elan.202100451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Hamdi Ben Halima
- University of Lyon Institute of Analytical Sciences 69100 Villeurbanne France
| | - Abdelhamid Errachid
- University of Lyon Institute of Analytical Sciences 69100 Villeurbanne France
| | | |
Collapse
|
15
|
Panahi A, Sadighbayan D, Forouhi S, Ghafar-Zadeh E. Recent Advances of Field-Effect Transistor Technology for Infectious Diseases. BIOSENSORS 2021; 11:103. [PMID: 33918325 PMCID: PMC8065562 DOI: 10.3390/bios11040103] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/22/2021] [Revised: 03/16/2021] [Accepted: 03/19/2021] [Indexed: 02/07/2023]
Abstract
Field-effect transistor (FET) biosensors have been intensively researched toward label-free biomolecule sensing for different disease screening applications. High sensitivity, incredible miniaturization capability, promising extremely low minimum limit of detection (LoD) at the molecular level, integration with complementary metal oxide semiconductor (CMOS) technology and last but not least label-free operation were amongst the predominant motives for highlighting these sensors in the biosensor community. Although there are various diseases targeted by FET sensors for detection, infectious diseases are still the most demanding sector that needs higher precision in detection and integration for the realization of the diagnosis at the point of care (PoC). The COVID-19 pandemic, nevertheless, was an example of the escalated situation in terms of worldwide desperate need for fast, specific and reliable home test PoC devices for the timely screening of huge numbers of people to restrict the disease from further spread. This need spawned a wave of innovative approaches for early detection of COVID-19 antibodies in human swab or blood amongst which the FET biosensing gained much more attention due to their extraordinary LoD down to femtomolar (fM) with the comparatively faster response time. As the FET sensors are promising novel PoC devices with application in early diagnosis of various diseases and especially infectious diseases, in this research, we have reviewed the recent progress on developing FET sensors for infectious diseases diagnosis accompanied with a thorough discussion on the structure of Chem/BioFET sensors and the readout circuitry for output signal processing. This approach would help engineers and biologists to gain enough knowledge to initiate their design for accelerated innovations in response to the need for more efficient management of infectious diseases like COVID-19.
Collapse
Affiliation(s)
- Abbas Panahi
- Biologically Sensors and Actuators (BioSA) Laboratory, Lassonde School of Engineering, York University, Keel Street, Toronto, ON M3J 1P3, Canada; (A.P.); (D.S.); (S.F.)
- Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Keel Street, Toronto, ON M3J 1P3, Canada
| | - Deniz Sadighbayan
- Biologically Sensors and Actuators (BioSA) Laboratory, Lassonde School of Engineering, York University, Keel Street, Toronto, ON M3J 1P3, Canada; (A.P.); (D.S.); (S.F.)
- Department of Biology, Faculty of Science, York University, Keel Street, Toronto, ON M3J 1P3, Canada
| | - Saghi Forouhi
- Biologically Sensors and Actuators (BioSA) Laboratory, Lassonde School of Engineering, York University, Keel Street, Toronto, ON M3J 1P3, Canada; (A.P.); (D.S.); (S.F.)
- Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Keel Street, Toronto, ON M3J 1P3, Canada
| | - Ebrahim Ghafar-Zadeh
- Biologically Sensors and Actuators (BioSA) Laboratory, Lassonde School of Engineering, York University, Keel Street, Toronto, ON M3J 1P3, Canada; (A.P.); (D.S.); (S.F.)
- Department of Electrical Engineering and Computer Science, Lassonde School of Engineering, York University, Keel Street, Toronto, ON M3J 1P3, Canada
- Department of Biology, Faculty of Science, York University, Keel Street, Toronto, ON M3J 1P3, Canada
| |
Collapse
|
16
|
Vlcnovska M, Stossova A, Kuchynka M, Dillingerova V, Polanska H, Masarik M, Hrstka R, Adam V, Kanicky V, Vaculovic T, Vaculovicova M. Comparison of Metal Nanoparticles (Au, Ag, Eu, Cd) Used for Immunoanalysis Using LA-ICP-MS Detection. Molecules 2021; 26:molecules26030630. [PMID: 33530345 PMCID: PMC7865668 DOI: 10.3390/molecules26030630] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/21/2021] [Accepted: 01/22/2021] [Indexed: 12/02/2022] Open
Abstract
Immunochemical methods are used not only in clinical practice for the diagnosis of a wide range of diseases but also in basic and advanced research. Based on the unique reaction between the antibody and its respective antigens, it serves to specifically recognize target molecules in biological complex samples. Current methods of labelling antibodies with elemental labels followed by detection by inductively coupled plasma mass spectrometry (ICP-MS) allow detection of multiple antigens in parallel in a single analysis. Using the laser ablation (LA) modality (LA-ICP-MS), it is also possible to monitor the spatial distribution of biogenic elements. Moreover, the employment of metal nanoparticle-labeled antibodies expands the applicability also to molecular imaging by LA-ICP-MS. In this work, conjugates of model monoclonal antibody (DO-1, recognizing p53 protein) with various metal nanoparticles-based labels were created and utilized in dot-blot analysis in order to compare their benefits and disadvantages. Based on experiments with the p53 protein standard, commercial kits of gold nanoparticles proved to be the most suitable for the preparation of conjugates. The LA-ICP-MS demonstrated very good repeatability, wide linear dynamic range (0.1–14 ng), and limit of detection was calculated as a 1.3 pg of p53 protein.
Collapse
Affiliation(s)
- Marcela Vlcnovska
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno, Czech Republic; (M.V.); (M.M.); (V.A.)
- Department of Pathological Physiology, Faculty of Medicine, Masaryk University/Kamenice 5, CZ-625 00 Brno, Czech Republic;
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00 Brno, Czech Republic
| | - Aneta Stossova
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 753/5, CZ-625 00 Brno, Czech Republic; (A.S.); (M.K.); (V.D.); (V.K.); (T.V.)
| | - Michaela Kuchynka
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 753/5, CZ-625 00 Brno, Czech Republic; (A.S.); (M.K.); (V.D.); (V.K.); (T.V.)
| | - Veronika Dillingerova
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 753/5, CZ-625 00 Brno, Czech Republic; (A.S.); (M.K.); (V.D.); (V.K.); (T.V.)
| | - Hana Polanska
- Department of Pathological Physiology, Faculty of Medicine, Masaryk University/Kamenice 5, CZ-625 00 Brno, Czech Republic;
| | - Michal Masarik
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno, Czech Republic; (M.V.); (M.M.); (V.A.)
- Department of Pathological Physiology, Faculty of Medicine, Masaryk University/Kamenice 5, CZ-625 00 Brno, Czech Republic;
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00 Brno, Czech Republic
| | - Roman Hrstka
- Research Centre for Applied Molecular Oncology, Masaryk Memorial Cancer Institute, Zluty kopec 7, CZ-656 53 Brno, Czech Republic;
| | - Vojtech Adam
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno, Czech Republic; (M.V.); (M.M.); (V.A.)
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00 Brno, Czech Republic
| | - Viktor Kanicky
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 753/5, CZ-625 00 Brno, Czech Republic; (A.S.); (M.K.); (V.D.); (V.K.); (T.V.)
| | - Tomas Vaculovic
- Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 753/5, CZ-625 00 Brno, Czech Republic; (A.S.); (M.K.); (V.D.); (V.K.); (T.V.)
| | - Marketa Vaculovicova
- Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00 Brno, Czech Republic; (M.V.); (M.M.); (V.A.)
- Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00 Brno, Czech Republic
- Correspondence:
| |
Collapse
|