1
|
Intravascular Ultrasound and Optical Coherent Tomography Combined Catheter. Interv Cardiol Clin 2023; 12:187-201. [PMID: 36922060 DOI: 10.1016/j.iccl.2022.12.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023]
Abstract
Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) are established intravascular imaging tools for evaluating plaque characteristics and volume, together with guiding percutaneous coronary interventions. The high tissue penetration of IVUS facilitates assessment of the entire vessel wall, whereas the higher resolution of OCT allows detailed assessment of endoluminal structures. A combined IVUS-OCT probe works synergistically, facilitating a greater understanding of de novo coronary artery disease and a better correlation with pathological specimens. In this review, we discuss the rationale and potential roles of the combined IVUS-OCT catheter system.
Collapse
|
2
|
Advances in Intravascular Ultrasound. INDIAN JOURNAL OF CARDIOVASCULAR DISEASE IN WOMEN 2023. [DOI: 10.25259/ijcdw_2_2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/31/2023]
Abstract
Since its inception, intravascular ultrasound (IVUS) and optical coherence tomography (OCT) have played a significant role in evaluating the pathophysiology of coronary artery disease (CAD) guiding the interventional and medical management of CAD improving outcomes in patients. Although the benefits of each of these modalities have been proven, due to some limitations, no single intravascular imaging technique has been proven to provide a detailed and complete evaluation of all CAD lesions. The use of different intravascular imaging modalities sequentially may lead to complications, which are cumbersome, consume time, and add financial burden to the patient. Recently, hybrid imaging catheters that combine OCT and IVUS benefits have been developed to limit these problems. Intravascular imaging techniques we are using currently have some drawbacks that hinder accurate assessment of plaque morphology and pathobiology as demonstrated in many histological studies, causing difficulty in identifying high-risk plaques. To overcome these limitations, great efforts have been put into developing hybrid, dual-probe catheters by combining imaging modalities to get an accurate analysis of plaque characteristics, and high-risk lesions. At present, many dual-probe catheters are available including combined IVUS-OCT, near-infrared spectroscopy-IVUS that is available commercially, the OCT-near infrared fluorescence (NIRF) molecular imaging, IVUS-NIRF, and combined fluorescence lifetime-IVUS imaging. Application of this combined multimodal imaging in clinical practice overcomes the limitations of standalone imaging and helps in providing a comprehensive and accurate visualization of plaque characteristics, composition, and plaque biology. The present article summarizes the advances in hybrid intravascular imaging, analyses the technical hindrances that should be known to have a use in the different clinical circumstances, and the till date shreds of evidence available from their first clinical application aiming to bring these modalities into the limelight and their potential role in the study of CAD.
Collapse
|
3
|
Volumetric Tissue Imaging of Surgical Tissue Specimens Using Micro-Computed Tomography: An Emerging Digital Pathology Modality for Nondestructive, Slide-Free Microscopy-Clinical Applications of Digital Pathology in 3 Dimensions. Am J Clin Pathol 2023; 159:242-254. [PMID: 36478204 DOI: 10.1093/ajcp/aqac143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 10/14/2022] [Indexed: 12/14/2022] Open
Abstract
OBJECTIVES Micro-computed tomography (micro-CT) is a novel, nondestructive, slide-free digital imaging modality that enables the acquisition of high-resolution, volumetric images of intact surgical tissue specimens. The aim of this systematic mapping review is to provide a comprehensive overview of the available literature on clinical applications of micro-CT tissue imaging and to assess its relevance and readiness for pathology practice. METHODS A computerized literature search was performed in the PubMed, Scopus, Web of Science, and CENTRAL databases. To gain insight into regulatory and financial considerations for performing and examining micro-CT imaging procedures in a clinical setting, additional searches were performed in medical device databases. RESULTS Our search identified 141 scientific articles published between 2000 and 2021 that described clinical applications of micro-CT tissue imaging. The number of relevant publications is progressively increasing, with the specialties of pulmonology, cardiology, otolaryngology, and oncology being most commonly concerned. The included studies were mostly performed in pathology departments. Current micro-CT devices have already been cleared for clinical use, and a Current Procedural Terminology (CPT) code exists for reimbursement of micro-CT imaging procedures. CONCLUSIONS Micro-CT tissue imaging enables accurate volumetric measurements and evaluations of entire surgical specimens at microscopic resolution across a wide range of clinical applications.
Collapse
|
4
|
Integrated US-OCT-NIRF Tri-Modality Endoscopic Imaging System for Pancreaticobiliary Duct Imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1970-1979. [PMID: 35377846 DOI: 10.1109/tuffc.2022.3164777] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Pancreaticobiliary carcinomas is a highly malignant gastrointestinal tumor. Most pancreaticobiliary cancers arise from epithelial proliferation within the pancreaticobiliary ducts, referred to as pancreatic intraepithelial neoplasias (PanINs). Some PanINs are benign metaplasia, while others progress to invasive duct adenocarcinoma (IDAC). However, there is no standard program to diagnose the progression from PanINs to IDAC. In this study, we present a tri-modality imaging system, which integrates ultrasound (US), optical coherence tomography (OCT), and near-infrared fluorescence (NIRF) for pancreaticobiliary duct imaging. This system can obtain OCT, US, and NIRF images in real-time with a frame rate of 30 frames per second. For the endoscopy probe with an outer diameter of 0.9 mm, the US transducer and fiber ball lens were placed back to back. In vivo experiments were performed on the rectums of Sprague-Dawley rats to demonstrate the imaging performance of US, OCT, and fluorescence angiography. An ex vivo experiment on a human pancreatic duct was performed for a more accurate assessment of the pancreaticobiliary duct. The tomography images of rat rectums and human pancreatic ducts were correlated with hematoxylin and eosin (H&E) histology to check the measurement accuracy. The integrated tri-modality system has great clinical potential in mechanism studies, early diagnosis, and prognosis evaluation of malignant pancreaticobiliary carcinomas.
Collapse
|
5
|
Advantages and prospects of optical coherence tomography in interventional therapy of coronary heart disease (Review). Exp Ther Med 2022; 23:255. [PMID: 35261627 PMCID: PMC8855506 DOI: 10.3892/etm.2022.11180] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2021] [Accepted: 01/13/2022] [Indexed: 11/06/2022] Open
|
6
|
Mechanically Rotating Intravascular Ultrasound (IVUS) Transducer: A Review. SENSORS (BASEL, SWITZERLAND) 2021; 21:3907. [PMID: 34198822 PMCID: PMC8201242 DOI: 10.3390/s21113907] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 05/31/2021] [Accepted: 06/03/2021] [Indexed: 12/30/2022]
Abstract
Intravascular ultrasound (IVUS) is a valuable imaging modality for the diagnosis of atherosclerosis. It provides useful clinical information, such as lumen size, vessel wall thickness, and plaque composition, by providing a cross-sectional vascular image. For several decades, IVUS has made remarkable progress in improving the accuracy of diagnosing cardiovascular disease that remains the leading cause of death globally. As the quality of IVUS images mainly depends on the performance of the IVUS transducer, various IVUS transducers have been developed. Therefore, in this review, recently developed mechanically rotating IVUS transducers, especially ones exploiting piezoelectric ceramics or single crystals, are discussed. In addition, this review addresses the history and technical challenges in the development of IVUS transducers and the prospects of next-generation IVUS transducers.
Collapse
|
7
|
Current clinical applications and potential perspective of micro-computed tomography in cardiovascular imaging: A systematic scoping review. Hellenic J Cardiol 2021; 62:399-407. [PMID: 33991670 DOI: 10.1016/j.hjc.2021.04.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2021] [Revised: 03/20/2021] [Accepted: 04/20/2021] [Indexed: 02/06/2023] Open
Abstract
Micro-computed tomography (micro-CT) constitutes an emerging imaging technique, which can be utilized in cardiovascular medicine to study in-detail the microstructure of heart and vessels. This paper aims to systematically review the clinical utility of micro-CT in cardiovascular imaging and propose future applications of micro-CT imaging in cardiovascular research. A systematic scoping review was conducted by searching for original studies written in English according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) extension for scoping reviews. Medline, Scopus, ClinicalTrials.gov, and the Cochrane library were systematically searched through December 11, 2020 to identify publications concerning micro-CT applications in cardiovascular imaging. Preclinical-animal studies and case reports were excluded. The Newcastle-Ottawa assessment scale for observational studies was used to evaluate study quality. In total, the search strategy identified 30 studies that report on micro-CT-based cardiovascular imaging and satisfy our eligibility criteria. Across all included studies, the total number of micro-CT scanned specimens was 1,227. Six studies involved postmortem 3D-reconstruction of congenital heart defects, while eleven studies described atherosclerotic vessel (coronary or carotid) characteristics. Thirteen other studies employed micro-CT for the assessment of medical devices (mainly stents or prosthetic valves). In conclusion, micro-CT is a novel imaging modality, effectively adapted for the 3D visualization and analysis of cardiac soft tissues and devices at high spatial resolution. Its increasing use could make significant contributions to our improved understanding of the histopathophysiology of cardiovascular diseases, and, thus, has the potential to optimize interventional procedures and technologies, and ultimately improve patient outcomes.
Collapse
|
8
|
Current status of hybrid intravascular ultrasound and optical coherence tomography catheter for coronary imaging and percutaneous coronary intervention. J Cardiol 2020; 77:435-443. [PMID: 33158714 DOI: 10.1016/j.jjcc.2020.08.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Accepted: 08/18/2020] [Indexed: 12/25/2022]
Abstract
Both intravascular ultrasound (IVUS) and optical coherence tomography (OCT) play a crucial role in elucidating the pathophysiology of coronary artery disease (CAD) with the goal to improve patient outcomes of medical and/or interventional CAD management. However, no single intravascular imaging technique has been proven to provide complete and detailed evaluation of all CAD lesions due to some limitations. Although sequential use of multiple modalities may sometimes be performed, there may be issues related to risk, time, and cost. To overcome these problems, several hybrids involving dual-probe combined IVUS-OCT catheters have been developed. The aim of this review article is to demonstrate some limitations of stand-alone imaging devices for evaluation of CAD, summarize the advances in hybrid IVUS-OCT imaging devices, discuss the technical challenges, and present the potential value in the clinical setting, especially in patients receiving medical or interventional CAD management.
Collapse
|
9
|
30/80 MHz Bidirectional Dual-Frequency IVUS Feasibility Evaluated In Vivo and for Stent Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2104-2112. [PMID: 32473846 DOI: 10.1016/j.ultrasmedbio.2020.03.032] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2019] [Revised: 03/15/2020] [Accepted: 03/29/2020] [Indexed: 06/11/2023]
Abstract
Although intravascular ultrasound (IVUS) is an important tool in guiding complex coronary interventions, the resolution of existing commercial IVUS devices is considerably poorer than that of optical coherence tomography. Dual-frequency IVUS (DF IVUS), incorporating a second, higher frequency transducer, has been proposed as a possible method of overcoming this limitation. Although preliminary studies have shown that DF IVUS can produce complementary images, including large-scale morphology and high detail of superficial features, it has not yet been determined that this approach would be feasible in a more clinically relevant environment. The purpose of this study was to demonstrate the first in vivo use of a 30/80 MHz DF IVUS catheter in visualizing coronary vessels in a porcine model. In addition, two commercially available stents were studied in vitro and in vivo. Clear subjective improvement of visualization of superficial structures is demonstrated, and sufficient dynamic range is achieved to image through both the catheter sheath and blood in vivo.
Collapse
|
10
|
A neurovascular high-frequency optical coherence tomography system enables in situ cerebrovascular volumetric microscopy. Nat Commun 2020; 11:3851. [PMID: 32737314 PMCID: PMC7395105 DOI: 10.1038/s41467-020-17702-7] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2019] [Accepted: 07/09/2020] [Indexed: 01/11/2023] Open
Abstract
Intravascular imaging has emerged as a valuable tool for the treatment of coronary and peripheral artery disease; however, no solution is available for safe and reliable use in the tortuous vascular anatomy of the brain. Endovascular treatment of stroke is delivered under image guidance with insufficient resolution to adequately assess underlying arterial pathology and therapeutic devices. High-resolution imaging, enabling surgeons to visualize cerebral arteries' microstructure and micron-level features of neurovascular devices, would have a profound impact in the research, diagnosis, and treatment of cerebrovascular diseases. Here, we present a neurovascular high-frequency optical coherence tomography (HF-OCT) system, including an imaging console and an endoscopic probe designed to rapidly acquire volumetric microscopy data at a resolution approaching 10 microns in tortuous cerebrovascular anatomies. Using a combination of in vitro, ex vivo, and in vivo models, the feasibility of HF-OCT for cerebrovascular imaging was demonstrated.
Collapse
|
11
|
Advances in IVUS/OCT and Future Clinical Perspective of Novel Hybrid Catheter System in Coronary Imaging. Front Cardiovasc Med 2020; 7:119. [PMID: 32850981 PMCID: PMC7411139 DOI: 10.3389/fcvm.2020.00119] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2020] [Accepted: 06/05/2020] [Indexed: 12/14/2022] Open
Abstract
Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) have been developed and improved as both diagnostic and guidance tools for interventional procedures over the past three decades. IVUS has a resolution of 100 μm with a high tissue penetration and capability of assessing the entire structure of a coronary artery including the external elastic membrane, whereas OCT has a higher resolution of 10–20 μm to assess endoluminal structures with a limited tissue penetration compared to IVUS. Recently, two companies, CONAVI and TERUMO, integrated IVUS and OCT into a single catheter system. With their inherent strength and limitations, the combined IVUS and OCT probes are complementary and work synergistically to enable a comprehensive depiction of coronary artery. In this review, we summarize the performance of the two intracoronary imaging modalities—IVUS and OCT—and discuss the expected potential of the novel hybrid IVUS–OCT catheter system in the clinical field.
Collapse
|
12
|
Back to the Future: Intravascular Imaging to Assess and Guide CTO PCI Procedures. JACC Cardiovasc Interv 2020; 13:1458-1459. [PMID: 32553334 DOI: 10.1016/j.jcin.2020.04.042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Accepted: 04/28/2020] [Indexed: 10/24/2022]
|
13
|
Current Advances in the Diagnostic Imaging of Atherosclerosis: Insights into the Pathophysiology of Vulnerable Plaque. Int J Mol Sci 2020; 21:ijms21082992. [PMID: 32340284 PMCID: PMC7216001 DOI: 10.3390/ijms21082992] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Revised: 04/02/2020] [Accepted: 04/15/2020] [Indexed: 12/13/2022] Open
Abstract
Atherosclerosis is a lipoprotein-driven inflammatory disorder leading to a plaque formation at specific sites of the arterial tree. After decades of slow progression, atherosclerotic plaque rupture and formation of thrombi are the major factors responsible for the development of acute coronary syndromes (ACSs). In this regard, the detection of high-risk (vulnerable) plaques is an ultimate goal in the management of atherosclerosis and cardiovascular diseases (CVDs). Vulnerable plaques have specific morphological features that make their detection possible, hence allowing for identification of high-risk patients and the tailoring of therapy. Plaque ruptures predominantly occur amongst lesions characterized as thin-cap fibroatheromas (TCFA). Plaques without a rupture, such as plaque erosions, are also thrombi-forming lesions on the most frequent pathological intimal thickening or fibroatheromas. Many attempts to comprehensively identify vulnerable plaque constituents with different invasive and non-invasive imaging technologies have been made. In this review, advantages and limitations of invasive and non-invasive imaging modalities currently available for the identification of plaque components and morphologic features associated with plaque vulnerability, as well as their clinical diagnostic and prognostic value, were discussed.
Collapse
|
14
|
|
15
|
Reliable in vivo intravascular imaging plaque characterization: A challenge unmet. Am Heart J 2019; 218:20-31. [PMID: 31655414 DOI: 10.1016/j.ahj.2019.07.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Accepted: 07/16/2019] [Indexed: 12/11/2022]
Abstract
Intravascular imaging has enabled in vivo assessment of coronary artery pathology and detection of plaque characteristics that are associated with increased vulnerability. Prospective invasive imaging studies of coronary atherosclerosis have demonstrated that invasive imaging modalities can detect lesions that are likely to progress and cause cardiovascular events and provided unique insights about atherosclerotic evolution. However, despite the undoubted value of the existing imaging techniques in clinical and research arenas, all the available modalities have significant limitations in assessing plaque characteristics when compared with histology. Hybrid/multimodality intravascular imaging appears able to overcome some of the limitations of standalone imaging; however, there are only few histology studies that examined their performance in evaluating plaque pathobiology. In this article, we review the evidence about the efficacy of standalone and multi-modality/hybrid intravascular imaging in assessing plaque morphology against histology, highlight the advantages and limitations of the existing imaging techniques and discuss the future potential of emerging imaging modalities in the study of atherosclerosis.
Collapse
|
16
|
Current clinical use of intravascular ultrasound imaging to guide percutaneous coronary interventions. Cardiovasc Interv Ther 2019; 35:30-36. [PMID: 31281937 DOI: 10.1007/s12928-019-00603-y] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Accepted: 06/24/2019] [Indexed: 12/17/2022]
Abstract
During the past three decades, since the invention of intravascular ultrasound (IVUS), it has become increasingly important as daily clinical applications. However, it evolved with no Japanese standards for the measurement of images, the index of percutaneous coronary intervention (PCI) procedures, and the reporting of results. Accordingly, the purpose of this review article is to provide an optimal and consistent approach to IVUS usage during PCI for clinicians and investigators.
Collapse
|
17
|
Multimodal Optical Medical Imaging Concepts Based on Optical Coherence Tomography. FRONTIERS IN PHYSICS 2018; 6. [PMID: 0 DOI: 10.3389/fphy.2018.00114] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
|
18
|
Abstract
Coronary artery disease is characterised by the development of atherosclerotic plaques and is associated with significant morbidity and mortality on a global level. However, many patients with atherosclerosis are asymptomatic and the prediction of acute coronary events is challenging. The role of imaging studies in characterising plaque morphology and stability is emerging as a valuable prognostic tool, while providing evidence for the beneficial effects of cholesterol-lowering therapy on plaque burden. This review provides an overview of contemporary studies describing the value of imaging strategies for atherosclerotic plaques. Coronary angiography is commonly used in the clinical setting, but requires a significant radiation dose (similar to computed tomography). Magnetic resonance imaging evaluation of coronary vessels would avoid exposure to ionising radiation, but is not yet feasible due to motion artefacts. The roles of alternative imaging techniques, including grey-scale intravascular ultrasound, optical coherence tomography and near-infrared spectroscopy have emerged in recent years. In particular, grey-scale intravascular ultrasound has been effectively applied to detect changes in plaque burden and features of plaques predictive of rupture, as well as plaque characteristics during cholesterol-lowering therapy, providing novel insights into factors that may contribute to treatment effectiveness. Challenges and limitations to the use of imaging techniques are considered in this context, along with future imaging strategies.
Collapse
|
19
|
IVUS-Guided Versus OCT-Guided Coronary Stent Implantation: A Critical Appraisal. JACC Cardiovasc Imaging 2018; 10:1487-1503. [PMID: 29216976 DOI: 10.1016/j.jcmg.2017.09.008] [Citation(s) in RCA: 136] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 08/11/2017] [Accepted: 09/28/2017] [Indexed: 12/17/2022]
Abstract
Procedural guidance with intravascular ultrasound (IVUS) imaging improves the clinical outcomes of patients undergoing percutaneous coronary intervention (PCI) by: 1) informing the necessity for lesion preparation; 2) directing appropriate stent sizing to maximize the final stent area and minimize geographic miss; 3) selecting the optimal stent length to cover residual disease adjacent to the lesion, thus minimizing geographic miss; 4) guiding optimal stent expansion; 5) identifying acute complications (edge dissection, stent malapposition, tissue protrusion); and 6) clarifying the mechanism of late stent failure (stent thrombosis, neointimal hyperplasia, stent underexpansion or fracture, or neoatherosclerosis). Optical coherence tomography (OCT) provides similar information to IVUS (with some important differences), also potentially improving acute and long-term patient outcomes compared to angiography-guided PCI. The purpose of this review is to describe the similarities and differences between IVUS and OCT technologies, and to highlight the evidence supporting their utility to improve PCI outcomes.
Collapse
|
20
|
Three-Dimensional Intravascular Reconstruction Techniques Based on Intravascular Ultrasound: A Technical Review. IEEE J Biomed Health Inform 2018; 22:806-817. [DOI: 10.1109/jbhi.2017.2703903] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
21
|
Development of a 3 French Dual-Frequency Intravascular Ultrasound Catheter. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:251-266. [PMID: 29150363 DOI: 10.1016/j.ultrasmedbio.2017.09.015] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2017] [Revised: 09/13/2017] [Accepted: 09/18/2017] [Indexed: 05/25/2023]
Abstract
Coronary plaque morphology, including plaque size and fibrous cap thickness, is thought to contribute to the risk of plaque rupture and future cardiac events. Dual-frequency intravascular ultrasound has been proposed as a possible technique to visualize both large-scale features and superficial detail of coronary plaque; however, it has not been found to be feasible within the constraints of a clinically functional intravascular ultrasound catheter. In this study, we describe the design and fabrication of a dual-frequency catheter using a bidirectional transducer stack with center frequencies of approximately 30 and 80 MHz. We describe how the high-frequency transducer achieves significantly improved axial and lateral resolution (16 and 120 µm, respectively, vs. 50 and 220 µm) at the expense of penetration depth. Finally, imaging of ex vivo human coronary artery segments reveals that the catheter can provide complementary images of the deeper arterial wall and superficial plaque features.
Collapse
|
22
|
Advances in Intravascular Imaging: New Insights into the Vulnerable Plaque from Imaging Studies. Korean Circ J 2017; 48:1-15. [PMID: 29171202 PMCID: PMC5764866 DOI: 10.4070/kcj.2017.0182] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2017] [Revised: 09/26/2017] [Accepted: 10/09/2017] [Indexed: 11/11/2022] Open
Abstract
The term “vulnerable plaque” denotes the plaque characteristics that are susceptible to coronary thrombosis. Previous post-mortem studies proposed 3 major mechanisms of coronary thrombosis: plaque rupture, plaque erosion, and calcified nodules. Of those, characteristics of rupture-prone plaque have been extensively studied. Pathology studies have identified the features of rupture-prone plaque including thin fibrous cap, large necrotic core, expansive vessel remodeling, inflammation, and neovascularization. Intravascular imaging modalities have emerged as adjunctive tools of angiography to identify vulnerable plaques. Multiple devices have been introduced to catheterization laboratories to date, including intravascular ultrasound (IVUS), virtual-histology IVUS, optical coherence tomography (OCT), coronary angioscopy, and near-infrared spectroscopy. With the use of these modalities, our understanding of vulnerable plaque has rapidly grown over the past several decades. One of the goals of intravascular imaging is to better predict and prevent future coronary events, for which prospective observational data is still lacking. OCT delineates microstructures of plaques, whereas IVUS visualizes macroscopic vascular structures. Specifically, plaque erosion, which has been underestimated in clinical practice, is gaining an interest due to the potential of OCT to make an in vivo diagnosis. Another potential future avenue for intravascular imaging is its use to guide treatment. Feasibility of tailored therapy for acute coronary syndromes (ACS) guided by OCT is under investigation. If it is proven to be effective, it may potentially lead to major shift in the management of millions of patients with ACS every year.
Collapse
|
23
|
Understanding Why and When Optical Coherence Tomography Does Not Detect Vulnerable Plaques: Is It Important? Circ Cardiovasc Interv 2017; 9:CIRCINTERVENTIONS.116.004144. [PMID: 27406991 DOI: 10.1161/circinterventions.116.004144] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
24
|
Intravascular imaging for characterization of coronary atherosclerosis. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2017. [DOI: 10.1016/j.cobme.2017.07.001] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
25
|
|
26
|
Polarization Sensitive Optical Coherence Tomography: A Review of Technology and Applications. APPLIED SCIENCES-BASEL 2017. [DOI: 10.3390/app7050474] [Citation(s) in RCA: 64] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
27
|
Hybrid intravascular imaging: recent advances, technical considerations, and current applications in the study of plaque pathophysiology. Eur Heart J 2017; 38:400-412. [PMID: 27118197 PMCID: PMC5837589 DOI: 10.1093/eurheartj/ehw097] [Citation(s) in RCA: 124] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/13/2015] [Revised: 01/31/2016] [Accepted: 02/22/2016] [Indexed: 11/14/2022] Open
Abstract
Cumulative evidence from histology-based studies demonstrate that the currently available intravascular imaging techniques have fundamental limitations that do not allow complete and detailed evaluation of plaque morphology and pathobiology, limiting the ability to accurately identify high-risk plaques. To overcome these drawbacks, new efforts are developing for data fusion methodologies and the design of hybrid, dual-probe catheters to enable accurate assessment of plaque characteristics, and reliable identification of high-risk lesions. Today several dual-probe catheters have been introduced including combined near infrared spectroscopy-intravascular ultrasound (NIRS-IVUS), that is already commercially available, IVUS-optical coherence tomography (OCT), the OCT-NIRS, the OCT-near infrared fluorescence (NIRF) molecular imaging, IVUS-NIRF, IVUS intravascular photoacoustic imaging and combined fluorescence lifetime-IVUS imaging. These multimodal approaches appear able to overcome limitations of standalone imaging and provide comprehensive visualization of plaque composition and plaque biology. The aim of this review article is to summarize the advances in hybrid intravascular imaging, discuss the technical challenges that should be addressed in order to have a use in the clinical arena, and present the evidence from their first applications aiming to highlight their potential value in the study of atherosclerosis.
Collapse
|
28
|
Intravascular hemodynamics and coronary artery disease: New insights and clinical implications. Hellenic J Cardiol 2016; 57:389-400. [PMID: 27894949 DOI: 10.1016/j.hjc.2016.11.019] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Accepted: 07/26/2016] [Indexed: 11/23/2022] Open
Abstract
Intracoronary hemodynamics play a pivotal role in the initiation and progression of the atherosclerotic process. Low pro-inflammatory endothelial shear stress impacts vascular physiology and leads to the occurrence of coronary artery disease and its implications.
Collapse
|
29
|
Non-invasive and invasive imaging of vulnerable coronary plaque. Trends Cardiovasc Med 2016; 26:538-47. [PMID: 27079893 DOI: 10.1016/j.tcm.2016.03.005] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2015] [Revised: 02/28/2016] [Accepted: 03/10/2016] [Indexed: 12/20/2022]
Abstract
Vulnerable plaque is characterized by a large necrotic core and an overlying thin fibrous cap. Non-invasive imaging modalities such as computed tomography angiography (CTA) and magnetic resonance imaging (MRI) allow for the assessment of morphological plaque characteristics, while positron emission tomography (PET) enables the detection of metabolic activity within the atherosclerotic lesions. Invasive imaging modalities such as intravascular ultrasound (IVUS), optical-coherence tomography (OCT), and intravascular MRI (IV-MRI) display plaques at a high spatial resolution. Near-infrared spectroscopy (NIRS) allows for the detection of chemical components of atherosclerotic plaques. In this review, we describe state-of-the-art non-invasive and invasive imaging modalities and stress the combination of their advantages to identify vulnerable plaque features.
Collapse
|
30
|
Integrated intravascular ultrasound and optical coherence tomography technology: a promising tool to identify vulnerable plaques [INVITED PAPER]. JOURNAL OF BIOMEDICAL PHOTONICS & ENGINEERING 2016; 1. [PMID: 28966987 DOI: 10.18287/jbpe-2015-1-4-209] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
Heart attack is mainly caused by the rupture of a vulnerable plaque. IVUS-OCT is a novel medical imaging modality that provides opportunities for accurate assessment of vulnerable plaques in vivo in patients. IVUS provides deep penetration to image the whole necrotic core while OCT enables accurate measurement of the fibrous cap of a plaque owing to its high resolution. In this paper, the authors describe the fundamentals, the technical designs and the applications of IVUS-OCT technology. Results from cadaver specimens are summarized, which indicated the complementary nature of OCT and IVUS for assessment of vulnerable plaques, plaque composition, and stent-tissue interactions. Furthermore, previously reported in vivo animal experiments are reviewed to assess the clinical adaptability of IVUS-OCT. Future directions for this technology are also discussed in this review.
Collapse
|
31
|
Ultrafast optical-ultrasonic system and miniaturized catheter for imaging and characterizing atherosclerotic plaques in vivo. Sci Rep 2015; 5:18406. [PMID: 26678300 PMCID: PMC4683418 DOI: 10.1038/srep18406] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2015] [Accepted: 11/17/2015] [Indexed: 12/17/2022] Open
Abstract
Atherosclerotic coronary artery disease (CAD) is the number one cause of death worldwide. The majority of CAD-induced deaths are due to the rupture of vulnerable plaques. Accurate assessment of plaques is crucial to optimize treatment and prevent death in patients with CAD. Current diagnostic techniques are often limited by either spatial resolution or penetration depth. Several studies have proved that the combined use of optical and ultrasonic imaging techniques increase diagnostic accuracy of vulnerable plaques. Here, we introduce an ultrafast optical-ultrasonic dual-modality imaging system and flexible miniaturized catheter, which enables the translation of this technology into clinical practice. This system can perform simultaneous optical coherence tomography (OCT)-intravascular ultrasound (IVUS) imaging at 72 frames per second safely in vivo, i.e., visualizing a 72 mm-long artery in 4 seconds. Results obtained in atherosclerotic rabbits in vivo and human coronary artery segments show that this ultrafast technique can rapidly provide volumetric mapping of plaques and clearly identify vulnerable plaques. By providing ultrafast imaging of arteries with high resolution and deep penetration depth simultaneously, this hybrid IVUS-OCT technology opens new and safe opportunities to evaluate in real-time the risk posed by plaques, detect vulnerable plaques, and optimize treatment decisions.
Collapse
|
32
|
Intracoronary imaging of coronary atherosclerosis: validation for diagnosis, prognosis and treatment. Eur Heart J 2015; 37:524-35a-c. [DOI: 10.1093/eurheartj/ehv642] [Citation(s) in RCA: 76] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2015] [Accepted: 11/09/2015] [Indexed: 12/11/2022] Open
|
33
|
Hybrid nanoprobes of bismuth sulfide nanoparticles and CdSe/ZnS quantum dots for mouse computed tomography/fluorescence dual mode imaging. J Nanobiotechnology 2015; 13:76. [PMID: 26510511 PMCID: PMC4625725 DOI: 10.1186/s12951-015-0138-9] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2015] [Accepted: 10/16/2015] [Indexed: 01/15/2023] Open
Abstract
Background X-ray computed tomography (CT) imaging can be used to reveal the three-dimensional structure of deep tissue with high spatial resolution. However, it cannot reveal molecular or cellular changes, and has great limitations in terms of specificity and sensitivity. Fluorescence imaging technology is one of the main methods used for the study of molecular events in vivo and has important applications in life science research. Therefore, the combination of CT and fluorescence imaging is an ideal dual-modal molecular imaging method, which can provide data on both molecular function and tissue structure, and has important research value. In a previous study, Bi2S3 nanoparticles were wrapped with quantum dots in SiO2 to generate CT and fluorescence imaging. However, this type of probe led to low survival and caused innegligible in vivo toxicity in mice. Therefore, it is necessary to develop new multifunctional probes that demonstrate biocompatibility and safety in vivo. Methods A polyethylene glycol-phospholipid bilayer structure was used to synthesize hybrid clusters containing hydrophobic Bi2S3 nanoparticles and quantum dots for combined CT/fluorescence imaging. Mean particle size, polydispersity index, and zeta potential were used to study the stability over an 8-week test period. In vivo CT and fluorescence imaging experiments were performed, and the in vivo safety of the probe was evaluated, using histopathological, biochemical, and blood analyses. Results The probe distinctly enhanced the CT contrast and had fluorescence imaging capability. In addition, the nanocomposite hybrid clusters showed a longer circulation time (>4 h) than iobitridol. The results also showed that the Bi2S3-QD@DSPE probe had good biocompatibility and safety, and did not affect normal organ functioning. Conclusions Bi2S3-QD@DSPE hybrid clusters exhibited remarkable performance in CT angiography and fluorescence imaging in vivo.
Collapse
|
34
|
Intravascular ultrasound and optical coherence tomography imaging of coronary atherosclerosis. Int J Cardiovasc Imaging 2015; 32:189-200. [DOI: 10.1007/s10554-015-0701-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2015] [Accepted: 07/01/2015] [Indexed: 11/30/2022]
|
35
|
A new methodology for accurate 3-dimensional coronary artery reconstruction using routine intravascular ultrasound and angiographic data: implications for widespread assessment of endothelial shear stress in humans. EUROINTERVENTION 2015; 9:582-93. [PMID: 23608530 DOI: 10.4244/eijv9i5a94] [Citation(s) in RCA: 59] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIMS To develop and validate a new methodology that allows accurate 3-dimensional (3-D) coronary artery reconstruction using standard, simple angiographic and intravascular ultrasound (IVUS) data acquired during routine catheterisation enabling reliable assessment of the endothelial shear stress (ESS) distribution. METHODS AND RESULTS Twenty-two patients (22 arteries: 7 LAD; 7 LCx; 8 RCA) who underwent angiography and IVUS examination were included. The acquired data were used for 3-D reconstruction using a conventional method and a new methodology that utilised the luminal 3-D centreline to place the detected IVUS borders and anatomical landmarks to estimate their orientation. The local ESS distribution was assessed by computational fluid dynamics. In corresponding consecutive 3 mm segments, lumen, plaque and ESS measurements in the 3-D models derived by the centreline approach were highly correlated to those derived from the conventional method (r>0.98 for all). The centreline methodology had a 99.5% diagnostic accuracy for identifying segments exposed to low ESS and provided similar estimations to the conventional method for the association between the change in plaque burden and ESS (centreline method: slope= -1.65%/Pa, p=0.078; conventional method: slope= -1.64%/Pa, p=0.084; p =0.69 for difference between the two methodologies). CONCLUSIONS The centreline methodology provides geometrically correct models and permits reliable ESS computation. The ability to utilise data acquired during routine coronary angiography and IVUS examination will facilitate clinical investigation of the role of local ESS patterns in the natural history of coronary atherosclerosis.
Collapse
|
36
|
Optimal flushing agents for integrated optical and acoustic imaging systems. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:56005. [PMID: 25985096 PMCID: PMC4435242 DOI: 10.1117/1.jbo.20.5.056005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2015] [Accepted: 04/20/2015] [Indexed: 05/11/2023]
Abstract
An increasing number of integrated optical and acoustic intravascular imaging systems have been developed and hold great promise for accurately diagnosing vulnerable plaques and guiding atherosclerosis treatment. However, in any intravascular environment, the vascular lumen is filled with blood, a high-scattering source for optical and high-frequency ultrasound signals. Blood must be flushed away to provide clearer images. To our knowledge, no research has been performed to find the ideal flushing agent for combined optical and acoustic imaging techniques. We selected three solutions as potential flushing agents for their image-enhancing effects: mannitol, dextran, and iohexol. Testing of these flushing agents was performed in a closed-loop circulation model and in vivo on rabbits. We found that a high concentration of dextran was the most useful for simultaneous intravascular ultrasound and optical coherence tomography imaging.
Collapse
|
37
|
Dual-element needle transducer for intravascular ultrasound imaging. J Med Imaging (Bellingham) 2015; 2:027001. [PMID: 26158118 DOI: 10.1117/1.jmi.2.2.027001] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2014] [Accepted: 03/24/2015] [Indexed: 11/14/2022] Open
Abstract
A dual-element needle transducer for intravascular ultrasound imaging has been developed. A low-frequency element and a high-frequency element were integrated into one device to obtain images which conveyed both low- and high-frequency information from a single scan. The low-frequency element with a center frequency of 48 MHz was fabricated from the single crystal form of lead magnesium niobate-lead titanate solid solution with two matching layers (MLs) and the high frequency element with a center frequency of 152 MHz was fabricated from lithium niobate with one ML. The measured axial and lateral resolutions were 27 and [Formula: see text], respectively, for the low-frequency element, and 14 and [Formula: see text], respectively, for the high-frequency element. The performance of the dual-element needle transducer was validated by imaging a tissue-mimicking phantom with lesion-mimicking area, and ex vivo rabbit aortas in water and rabbit whole blood. The results suggest that a low-frequency element effectively provides depth resolved images of the whole vessel and its adjacent tissue, and a high-frequency element visualizes detailed structure near the surface of the lumen wall in the presence of blood within the lumen. The advantages of a dual-element approach for intravascular imaging are also discussed.
Collapse
|
38
|
Accuracy of OCT, Grayscale IVUS, and Their Combination for the Diagnosis of Coronary TCFA. JACC Cardiovasc Imaging 2015; 8:451-460. [DOI: 10.1016/j.jcmg.2014.10.015] [Citation(s) in RCA: 103] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2014] [Revised: 09/30/2014] [Accepted: 10/03/2014] [Indexed: 11/25/2022]
|
39
|
Erratum: Multi-frequency intravascular ultrasound (IVUS) imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2015; 62:604. [PMID: 25768827 DOI: 10.1109/tuffc.2015.007057] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
|
40
|
A prototype hand-held tri-modal instrument for in vivo ultrasound, photoacoustic, and fluorescence imaging. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2015; 86:034901. [PMID: 25832265 DOI: 10.1063/1.4915146] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Multi-modality imaging is beneficial for both preclinical and clinical applications as it enables complementary information from each modality to be obtained in a single procedure. In this paper, we report the design, fabrication, and testing of a novel tri-modal in vivo imaging system to exploit molecular/functional information from fluorescence (FL) and photoacoustic (PA) imaging as well as anatomical information from ultrasound (US) imaging. The same ultrasound transducer was used for both US and PA imaging, bringing the pulsed laser light into a compact probe by fiberoptic bundles. The FL subsystem is independent of the acoustic components but the front end that delivers and collects the light is physically integrated into the same probe. The tri-modal imaging system was implemented to provide each modality image in real time as well as co-registration of the images. The performance of the system was evaluated through phantom and in vivo animal experiments. The results demonstrate that combining the modalities does not significantly compromise the performance of each of the separate US, PA, and FL imaging techniques, while enabling multi-modality registration. The potential applications of this novel approach to multi-modality imaging range from preclinical research to clinical diagnosis, especially in detection/localization and surgical guidance of accessible solid tumors.
Collapse
|
41
|
|
42
|
Integrated IVUS-OCT Imaging for Atherosclerotic Plaque Characterization. IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS : A PUBLICATION OF THE IEEE LASERS AND ELECTRO-OPTICS SOCIETY 2014; 20:7100108. [PMID: 24771992 PMCID: PMC3996710 DOI: 10.1109/jstqe.2013.2274724] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
For the diagnosis of atherosclerosis, biomedical imaging techniques such as intravascular ultrasound (IVUS) and optical coherence tomography (OCT) have been developed. The combined use of IVUS and OCT is hypothesized to remarkably increase diagnostic accuracy of vulnerable plaques. We have developed an integrated IVUS-OCT imaging apparatus, which includes the integrated catheter, motor drive unit, and imaging system. The dual-function imaging catheter has the same diameter of current clinical standard. The imaging system is capable for simultaneous IVUS and OCT imaging in real time. Ex vivo and in vivo experiments on rabbits with atherosclerosis were conducted to demonstrate the feasibility and superiority of the integrated intravascular imaging modality.
Collapse
|
43
|
Optical coherence tomography guided PCI - initial experience at Apollo Health City, Jubilee Hills, Hyderabad. Indian Heart J 2014; 66:31-7. [PMID: 24581093 PMCID: PMC4054838 DOI: 10.1016/j.ihj.2013.12.048] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2013] [Accepted: 12/15/2013] [Indexed: 01/27/2023] Open
Abstract
Background The capability of OCT to examine the structure of the arterial wall before or after PCI is superior to those of other imaging modalities. Therefore the application of OCT during PCI seems logical and has the potential to enhance our performance during the PCI procedures. Methods OCT was performed in fifty-two patients out of which, 45 patients underwent PCI. Out of these 45 patients, in 25 patients both pre and post PCI OCT assessment was done. In 20 patients only post PCI OCT assessment was done. In seven patients PCI was not done due to nonsignificant obstruction, these seven patients were not included in final analysis. Results Over all OCT leads to management changes in 65% of the time it was used. Alteration of stent length was done in 56% of the cases when evaluated pre PCI. Alteration of stent diameter was done in 36% cases when evaluated pre PCI. Treatment of malapposition was done in 24% of total cases. Further balloon dilatation for vessel expansion was done in 15% of total cases. In one case left main stenting was done after proximal edge dissection. Conclusion OCT makes better visualization of plaque, thrombus, stent malapposition, dissection, plaque prolapse and helps in optimization of PCI results. More extensive, long-term studies will be needed to assess the prognostic implications of these findings.
Collapse
|
44
|
How clinically effective is intravascular ultrasound in interventional cardiology? Present and future perspectives. Expert Rev Med Devices 2014; 10:735-49. [DOI: 10.1586/17434440.2013.841353] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
45
|
Clinical Utility and Significance of Intravascular Ultrasound and Optical Coherence Tomography in Guiding Percutaneous Coronary Interventions. Circ J 2014; 79:24-33. [DOI: 10.1253/circj.cj-14-1044] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
46
|
Abstract
Intravascular ultrasound (IVUS) has expanded our understanding of atherosclerotic plaque morphology, and provides an opportunity to guide cardiovascular interventions and evaluate results. Use of this technique requires understanding of ultrasound physics, catheter differences, skills in vessel, plaque and stent quantification and knowledge of artifacts and various physiologic and pathologic findings. Optimal cardiovascular interventions should result in absence of inflow or outflow obstruction, precise geographic landing, while attaining the largest feasible luminal gain without plaque protrusion, vessel dissection or perforation and, if deployed, with complete stent expansion and apposition to the vessel wall. IVUS is safe, cost efficient and effectively optimises cardiovascular interventions. In addition, IVUS improves outcomes when used to guide coronary interventions using bare metal stents (BMS) and drug eluting stents (DES). The role of IVUS in endovascular therapy is rapidly expanding. This review will focus on the impact of IVUS in clinical practice.
Collapse
|
47
|
New Developments in Hybrid Optical Coherence Tomographic Imaging: Current Status and Potential Implications in Clinical Practice and Research. CURRENT CARDIOVASCULAR IMAGING REPORTS 2013. [DOI: 10.1007/s12410-013-9218-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
48
|
Early detection and invasive passivation of future culprit lesions: a future potential or an unrealistic pursuit of chimeras? Am Heart J 2013; 165:869-881.e4. [PMID: 23708157 DOI: 10.1016/j.ahj.2013.02.015] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2012] [Accepted: 02/18/2013] [Indexed: 11/22/2022]
Abstract
New advances in image and signal processing have allowed the development of numerous invasive and noninvasive imaging modalities that have revealed details of plaque pathology and allowed us to study in vivo the atherosclerotic evolution. Recent natural history of atherosclerosis studies permitted us to evaluate changes in the compositional and morphological characteristics of the plaque and identify predictors of future events. The idea of being able to identify future culprit lesions and passivate these plaques has gradually matured, and small scale studies have provided proofs about the feasibility of this concept. This review article summarizes the recent advances in the study of atherosclerosis, cites the current evidence, highlights our limitations in understanding the evolution of the plaque and in predicting plaque destabilization, and discusses the potentiality of an early invasive sealing of future culprit lesions.
Collapse
|
49
|
Hybrid Intravascular Imaging. J Am Coll Cardiol 2013; 61:1369-78. [DOI: 10.1016/j.jacc.2012.10.057] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2012] [Revised: 10/06/2012] [Accepted: 10/09/2012] [Indexed: 02/02/2023]
|