1
|
Li N, Desiderio DM, Zhan X. The use of mass spectrometry in a proteome-centered multiomics study of human pituitary adenomas. Mass Spectrom Rev 2022; 41:964-1013. [PMID: 34109661 DOI: 10.1002/mas.21710] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 05/21/2021] [Accepted: 05/26/2021] [Indexed: 06/12/2023]
Abstract
A pituitary adenoma (PA) is a common intracranial neoplasm, and is a complex, chronic, and whole-body disease with multicausing factors, multiprocesses, and multiconsequences. It is very difficult to clarify molecular mechanism and treat PAs from the single-factor strategy model. The rapid development of multiomics and systems biology changed the paradigms from a traditional single-factor strategy to a multiparameter systematic strategy for effective management of PAs. A series of molecular alterations at the genome, transcriptome, proteome, peptidome, metabolome, and radiome levels are involved in pituitary tumorigenesis, and mutually associate into a complex molecular network system. Also, the center of multiomics is moving from structural genomics to phenomics, including proteomics and metabolomics in the medical sciences. Mass spectrometry (MS) has been extensively used in phenomics studies of human PAs to clarify molecular mechanisms, and to discover biomarkers and therapeutic targets/drugs. MS-based proteomics and proteoform studies play central roles in the multiomics strategy of PAs. This article reviews the status of multiomics, multiomics-based molecular pathway networks, molecular pathway network-based pattern biomarkers and therapeutic targets/drugs, and future perspectives for personalized, predeictive, and preventive (3P) medicine in PAs.
Collapse
Affiliation(s)
- Na Li
- Shandong Key Laboratory of Radiation Oncology, Cancer Hospital of Shandong First Medical University, Jinan, Shandong, China
- Medical Science and Technology Innovation Center, Shandong First Medical University, Jinan, Shandong, China
| | - Dominic M Desiderio
- The Charles B. Stout Neuroscience Mass Spectrometry Laboratory, Department of Neurology, College of Medicine, University of Tennessee Health Science Center, Memphis, Tennessee, USA
| | - Xianquan Zhan
- Shandong Key Laboratory of Radiation Oncology, Cancer Hospital of Shandong First Medical University, Jinan, Shandong, China
- Medical Science and Technology Innovation Center, Shandong First Medical University, Jinan, Shandong, China
| |
Collapse
|
2
|
Maus A, Mignon R, Basile F. Enhanced protein identification using graphite-modified MALDI plates for offline LC-MALDI-MS/MS bottom-up proteomics. Anal Biochem 2018; 545:31-37. [PMID: 29326070 DOI: 10.1016/j.ab.2018.01.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Revised: 12/22/2017] [Accepted: 01/02/2018] [Indexed: 10/18/2022]
Abstract
The use of offline liquid chromatography-matrix assisted laser desorption/ionization (LC-MALDI) tandem mass spectrometry (MS/MS) for bottom-up proteomics offers advantages in terms of cost, ease of use, and the time-decoupled nature of the separation step and the mass analysis. A method was developed to improve the capabilities of LC-MALDI-MS/MS in terms of protein identification in a bottom-up proteomic workflow. Enhanced protein identification is achieved by an increase in the MALDI signal intensity of the precursor peptides brought about by coating the MALDI plate with a thin film of graphite powder. Using the Escherichia coli proteome, it is demonstrated that the graphite-modified MALDI plates used in an offline LC-MALDI-MS/MS bottom-up protocol led to a 50-135% increase in the number of peptide identifications, and a concomitant 21%-105% increase in the number of proteins inferred. We identify factors that lead to improvements in peptide sequence identifications and in the number of unique proteins identified when compared to using an unmodified MALDI plate. These improvements are achieved using a low cost approach that it is easy to implement, requires no hardware/protocol modification, it is compatible with LC and adds no additional analysis time.
Collapse
Affiliation(s)
- Anthony Maus
- Department of Chemistry, University of Wyoming, 1000 E. University Ave., Laramie, WY 82072, United States
| | - Rudolph Mignon
- Department of Chemistry, University of Wyoming, 1000 E. University Ave., Laramie, WY 82072, United States
| | - Franco Basile
- Department of Chemistry, University of Wyoming, 1000 E. University Ave., Laramie, WY 82072, United States.
| |
Collapse
|
3
|
Abstract
Biomarkers are biomolecules that serve as indicators of biological and pathological processes, or physiological and pharmacological responses to a drug treatment. Because of the high abundance of albumin and heterogeneity of plasma lipoproteins and glycoproteins, biomarkers are difficult to identify in human serum. Due to the clinical significance the identification of disease biomarkers in serum holds great promise for personalized medicine, especially for disease diagnosis and prognosis. This review summarizes some common and emerging proteomics techniques utilized in the separation of serum samples and identification of disease signatures. The practical application of each protein separation or identification technique is analyzed using specific examples. Biomarkers of cancers of prostate, breast, ovary, and lung in human serum have been reviewed, as well as those of heart disease, arthritis, asthma, and cystic fibrosis. Despite the advancement of technology few biomarkers have been approved by the Food and Drug Administration for disease diagnosis and prognosis due to the complexity of structure and function of protein biomarkers and lack of high sensitivity, specificity, and reproducibility for those putative biomarkers. The combination of different types of technologies and statistical analysis may provide more effective methods to identify and validate new disease biomarkers in blood.
Collapse
Affiliation(s)
- Ziad J. Sahab
- Department of Chemistry and Biochemistry and Institute of Molecular Biophysics, Florida State University, Tallahassee, FL 32306-4390, U.S.A
| | - Suzan M. Semaan
- Department of Chemistry and Biochemistry and Institute of Molecular Biophysics, Florida State University, Tallahassee, FL 32306-4390, U.S.A
| | - Qing-Xiang Amy Sang
- Department of Chemistry and Biochemistry and Institute of Molecular Biophysics, Florida State University, Tallahassee, FL 32306-4390, U.S.A
| |
Collapse
|
4
|
Peš O, Preisler J. Off-line coupling of microcolumn separations to desorption mass spectrometry. J Chromatogr A 2010; 1217:3966-77. [DOI: 10.1016/j.chroma.2010.02.058] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2009] [Revised: 02/22/2010] [Accepted: 02/24/2010] [Indexed: 01/13/2023]
|
5
|
Chen Y, Liu Y, Allegood J, Wang E, Cachón-González B, Cox TM, Merrill AH, Sullards MC. Imaging MALDI mass spectrometry of sphingolipids using an oscillating capillary nebulizer matrix application system. Methods Mol Biol 2010; 656:131-46. [PMID: 20680588 PMCID: PMC3501677 DOI: 10.1007/978-1-60761-746-4_7] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Matrix deposition is a critical step in tissue imaging by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). It greatly affects the quality of MALDI imaging, especially for the analytes (such as lipids) that may easily dissolve in the solvent used for the matrix application. This chapter describes the use of an oscillating capillary nebulizer (OCN) to spray small droplets of matrix aerosol onto the sample surface for improved matrix homogeneity, reduced crystal size, and controlled solvent effects. This protocol allows visualization of many different lipid species and, of particular interest, sphingolipids in tissue slices of Tay-Sachs/Sandhoff disease by imaging MALDI-MS. The structures of these lipids were identified by analysis of tissue extracts using electrospray ionization in conjunction with tandem mass spectrometry (MS/MS and MS(3)). These results illustrate the usefulness of tissue imaging MALDI-MS with matrix deposition by OCN for the molecular analysis in normal physiology and pathology. In addition, the observation of numerous lipid subclasses with distinct localizations in the brain slices demonstrates that imaging MALDI-MS could be effectively used for "lipidomic" studies.
Collapse
Affiliation(s)
- Yanfeng Chen
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, GA, USA
| | | | | | | | | | | | | | | |
Collapse
|
6
|
Nesbitt CA, Zhang H, Yeung KK. Recent applications of capillary electrophoresis–mass spectrometry (CE–MS): CE performing functions beyond separation. Anal Chim Acta 2008; 627:3-24. [DOI: 10.1016/j.aca.2008.04.023] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2008] [Revised: 04/02/2008] [Accepted: 04/08/2008] [Indexed: 11/18/2022]
|
7
|
Chen Y, Allegood J, Liu Y, Wang E, Cachón-Gonzalez B, Cox TM, Merrill AH, Sullards MC. Imaging MALDI mass spectrometry using an oscillating capillary nebulizer matrix coating system and its application to analysis of lipids in brain from a mouse model of Tay-Sachs/Sandhoff disease. Anal Chem 2008; 80:2780-8. [PMID: 18314967 DOI: 10.1021/ac702350g] [Citation(s) in RCA: 130] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The quality of tissue imaging by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) depends on the effectiveness of the matrix deposition, especially for lipids that may dissolve in the solvent used for the matrix application. This article describes the use of an oscillating capillary nebulizer (OCN) to spray small droplets of matrix aerosol onto the sample surface for improved matrix homogeneity, reduced crystal size, and controlled solvent effects. This system was then applied to the analysis of histological slices of brains from mice with homozygous disruption of the hexb gene (hexb-/-), a model of Tay-Sachs and Sandhoff disease, versus the functionally normal heterozygote (hexb+/-) by imaging MALDI-MS. This allowed profiling and localization of many different lipid species, and of particular interest, ganglioside GM2, asialo-GM2 (GA2), and sulfatides (ST). The presence of these compounds was confirmed by analysis of brain extracts using electrospray ionization in conjunction with tandem mass spectrometry (MS/MS). The major fatty acid of the ceramide backbone of both GM2 and GA2 was identified as stearic acid (18:0) versus nervonic acid (24:1) for ST by both tissue-imaging MS and ESI-MS/MS. GM2 and GA2 were highly elevated in hexb-/- and were both localized in the granular cell region of the cerebellum. ST, however, was localized mainly in myelinated fiber (white matter) region of the cerebellum as well as in the brain stem with a relatively uniform distribution and had similar relative signal intensity for both hexb+/- and hexb-/- brain. It was also observed that there were distinct localizations for numerous other lipid subclasses; hence, imaging MALDI-MS could be used for "lipidomic" studies. These results illustrate the usefulness of tissue-imaging MALDI-MS with matrix deposition by OCN for histologic comparison of lipids in tissues such as brains from this mouse model of Tay-Sachs and Sandhoff disease.
Collapse
Affiliation(s)
- Yanfeng Chen
- School of Chemistry and Biochemistry, The Parker H. Petit Institute for Bioengineering and Bioscience, 315 Ferst Drive, Georgia Institute of Technology, Atlanta, Georgia 30332-0363, USA
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Abstract
Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the detection of proteins ranging in molecular mass from 12 to 66 kDa. Proteins were uniformly deposited on a solid surface without pretreatment and analyzed with a DESI source coupled to a quadrupole ion trap mass spectrometer. DESI-MS parameters optimized for protein detection included solvent flow rate, temperature of heated capillary tube, incident and reflection angle, sheath gas pressure, and ESI voltage. Detection limits were obtained for all protein standards, and they were found to decrease with decreasing protein molecular mass: for cytochrome c (12.3 kDa) and lysozyme (14.3 kDa) a detection limit of 4 ng/mm2 was obtained; for apomyoglobin (16.9 kDa) 20 ng/mm2; for beta-lactoglobulin B (18.2 kDa) 50 ng/mm2; and for chymotrypsinogen A (25.6 kDa) 100 ng/mm2. The DESI-MS analysis of higher molecular mass proteins such as ovalbumin (44.4 kDa) and bovine serum albumin (66.4 kDa) yielded mass spectra of low signal-to-noise ratio, making their detection and molecular weight determination difficult. In this study, DESI-MS proved to be a rapid and robust method for accurate MW determination for proteins up to 17 kDa under ambient conditions. Finally, we demonstrated the DESI-MS detection of the bacteriophage MS2 capsid protein from crude samples with minimal sample preparation.
Collapse
Affiliation(s)
- Yong-Seung Shin
- Department of Chemistry, University of Wyoming, 1000 E. University Ave., Laramie, Wyoming 82071
| | - Barbara Drolet
- Arthropod-Borne Animal Diseases Research Laboratory, ARS, USDA, University of Wyoming, 1000 E. University Ave., Laramie, Wyoming 82071
| | - Richard Mayer
- Arthropod-Borne Animal Diseases Research Laboratory, ARS, USDA, University of Wyoming, 1000 E. University Ave., Laramie, Wyoming 82071
| | - Kurt Dolence
- School of Pharmacy, University of Wyoming, 1000 E. University Ave., Laramie, Wyoming 82071
| | - Franco Basile
- Department of Chemistry, University of Wyoming, 1000 E. University Ave., Laramie, Wyoming 82071
| |
Collapse
|
9
|
Abstract
Liquid chromatography-matrix-assisted laser desorption/ionization mass spectrometry represents a sensitive, hyphenated MS- and MS/MS-technique with a broad range of applications in all areas ofproteome analysis. Whereas a number of interface types have been developed for coupling MALDI MS and liquid chromatography, in this chapter selected on-line and off-line types and techniques will be discussed with respect to their individual properties and performance. The technique is especially attractive in off-line mode where LC-separation and MS analyses are decoupled and each step can be performed at its individual optimum. Different speed of chromatographic separation and achievement of S/N criteria in MS or MS/MS mode can be optimized independently by individual adjustment of specific operating parameters. This flexibility makes LC-MALDI MS attractive for the analysis of peptide mixtures from low to medium complexity. Using sequential MS analysis of parallel LC runs (multiplexing), even highly complex samples can be handled. Quantitation at the MS and MS/MS level can be accomplished by a variety of labeling techniques, where the predominant formation of singly charged ions in MALDI alleviates the assignment of isotopomers. After discussing the level of complementarity between LC-MALDI and LC-ESI MS, selected applications of LC-MALDI MS are presented. Examples of membrane protein analysis applying 1D SDS PAGE are discussed in detail as well as applications in protein interaction analysis. These application examples clearly show that in all respects LC-MALDI MS and MS/MS are flexible and sensitive techniques which can be adapted to a wide range of different workflows.
Collapse
|
10
|
McComb ME, Perlman DH, Huang H, Costello CE. Evaluation of an on-target sample preparation system for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry in conjunction with normal-flow peptide high-performance liquid chromatography for peptide mass fingerprint analyses. Rapid Commun Mass Spectrom 2007; 21:44-58. [PMID: 17133622 DOI: 10.1002/rcm.2805] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Large-scale mass spectrometry (MS)-based proteomic analyses require high-throughput sample preparation techniques due to the increasing numbers of samples that make up a typical proteomics experiment. Moreover, extensive sample pre-treatment steps are necessary prior to MS acquisition for even the most rapid and robust MS-based proteomics methodology, matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS followed by peptide mass fingerprinting (PMF) analysis. These include sample purification and fractionation, removal of digestion buffers or solvents, and spotting of sample with matrix onto the MALDI target. These multiple steps of time-consuming sample handling can result in high overall analysis costs and the likelihood of sample contamination and loss. In order to overcome some of these limitations in sample processing, we have investigated the use of a novel, simple, inexpensive 96-well elastomeric array that affixes to a MALDI target to create an on-target 96-well plate that accommodates a high solution volume (ca. 200 microL), thereby enabling the on-target processing of samples for MALDI-TOFMS. We explored several factors that influence MALDI sample preparation: type of matrix, solution volume, solution organic composition, solution drying rates and matrix/analyte co-crystallization methods. We also investigated the use of the 96-well elastomeric device for coupling MALDI-TOFMS analysis directly to high flow rate (1 mL/min) reversed-phase (rp)-HPLC. By developing an optimized, robust sample preparation protocol, we were able to obtain mass spectra with a high signal-to-noise ratio from peptide standards present at the 50-fmol level in large starting volumes of solution. PMF analyses were possible from 1-pmol and 500-fmol protein-digest standards. Coupling the device to high-flow HPLC (750 microL/min) yielded a robust and semi-automated means to obtain enhanced MALDI-TOFMS data at 500 ng of protein digest. These methodologies developed for this simple, on-target, elastomeric device show promise for streamlining the sample preparation process from HPLC to MALDI-MS.
Collapse
Affiliation(s)
- Mark E McComb
- Cardiovascular Proteomics Center, Boston University School of Medicine, Boston, MA 02118-2646, USA.
| | | | | | | |
Collapse
|
11
|
Abstract
The eye lens is a fascinating organ as it is in essence living transparent matter. Lenticular transparency is achieved through the peculiarities of lens morphology, a semi-apoptotic process where cells elongate and loose their organelles and the precise molecular arrangement of the bulk of soluble lenticular proteins, the crystallins. The 16 crystallins ubiquitous in mammals and their modifications have been extensively characterized by 2-DE, liquid chromatography, mass spectrometry and other protein analysis techniques. The various solubility dependant fractions as well as subproteomes of lenticular morphological sections have also been explored in detail. Extensive post translational modification of the crystallins is encountered throughout the lens as a result of ageing and disease resulting in a vast number of protein species. Proteomics methodology is therefore ideal to further comprehensive understanding of this organ and the factors involved in cataractogenesis.
Collapse
Affiliation(s)
- W Hoehenwarter
- Max Planck Institute for Infection Biology, Core Facility Protein Analysis, Berlin, Germany
| | | | | |
Collapse
|
12
|
Young JB, Li L. An impulse-driven liquid-droplet deposition interface for combining LC with MALDI MS and MS/MS. J Am Soc Mass Spectrom 2006; 17:325-34. [PMID: 16443366 DOI: 10.1016/j.jasms.2005.11.018] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2005] [Revised: 11/18/2005] [Accepted: 11/28/2005] [Indexed: 05/06/2023]
Abstract
A simple and robust impulse-driven droplet deposition system was developed for off-line liquid chromatography matrix-assisted laser desorption ionization mass spectrometry (LC-MALDI MS). The system uses a solenoid operated with a pulsed voltage power supply to generate impulses that dislodge the hanging droplets from the LC outlet directly to a MALDI plate via a momentum transfer process. There is no contact between the LC outlet and the collection surface. The system is compatible with solvents of varying polarity and viscosity, and accommodates the use of hydrophobic and hydrophilic MALDI matrices. MALDI spots are produced on-line with the separation, and do not require further processing before MS analysis. It is shown that high quality MALDI spectra from 5 fmol of pyro-Glu-fibrinopeptide deposition after LC separation could be obtained using the device, indicating that there was no sample loss in the interface. To demonstrate the analytical performance of the system as a proteome analysis tool, a range of BSA digest concentrations covering about 3 orders of magnitude, from 5 fmol to 1 pmol, were analyzed by LC-MALDI quadrupole time-of-flight MS, yielding 6 and 57% amino acid sequence coverage, respectively. In addition, a complex protein mixture of an E. coli cell extract was tryptically digested and analyzed by LC-MALDI MS, resulting in the detection of a total of 409 unique peptides from 100 fractions of 15-s intervals.
Collapse
Affiliation(s)
- J Bryce Young
- Department of Chemistry, University of Alberta, Edmonton, Alberta, Canada
| | | |
Collapse
|
13
|
Shcherbyna SV, Bohme DK, Baranov VI, Loboda A, Swartz CR, Anthony JE. Clustering of pentacene and functionalized pentacene ions in a matrix-assisted laser desorption/ionization orthogonal TOF mass spectrometer. J Am Soc Mass Spectrom 2006; 17:222-9. [PMID: 16413203 DOI: 10.1016/j.jasms.2005.10.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2005] [Revised: 10/21/2005] [Accepted: 10/25/2005] [Indexed: 05/06/2023]
Abstract
A high-performance orthogonal time-of flight (TOF) mass spectrometer, in combination with the matrix assisted laser desorption/ionization (MALDI) source operating at elevated pressure ( approximately 1 torr in N(2)), was used to perform MALDI-TOF analyses of pentacene and some of its derivatives with and without an added matrix. These molecules are among the most interesting semiconductor materials for organic thin film transistor applications (OTFT). The observation of ion-molecule reactions between "cold" analyte ions and neutral analyte molecules in the gas phase has provided some insight into the mechanism of pentacene cluster formation and its functionalized derivatives. Furthermore, some of the matrices employed to assist the desorption/ionization process of these compounds were observed to influence the outcome via ion-molecule reactions of analyte ions and matrix molecules in the gas phase. The stability and reactivity of the compounds and their clusters in the MALDI plume during gas-phase expansion were evaluated; possible structures of the resulting clusters are discussed. The MALDI-TOF technique was also helpful in distinguishing between two isomeric forms of bis-[(triisopropylsilyl)-ethynyl]-pentacene.
Collapse
Affiliation(s)
- Svitlana V Shcherbyna
- Department of Physics and Astronomy, Department of Chemistry, Center for Research in Mass Spectrometry, York University, Toronto, Ontario, Canada
| | | | | | | | | | | |
Collapse
|
14
|
Creaser CS, Green PS, Kilby PM, Ratcliffe L. Capillary liquid chromatography/atmospheric-pressure matrix-assisted laser desorption/ionisation ion trap mass spectrometry: a comparison with liquid chromatography/matrix-assisted laser desorption/ionisation time-of-flight and liquid chromatography/electrospray ionisation quadrupole time-of-flight for the identification of tryptic peptides. Rapid Commun Mass Spectrom 2006; 20:829-36. [PMID: 16470569 DOI: 10.1002/rcm.2376] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
The atmospheric-pressure matrix-assisted laser desorption/ionisation quadrupole ion trap (AP-MALDI-QIT) analysis of tryptic peptides is reported following capillary liquid chromatographic (LC) separation and direct analysis of a protein digest. Peptide fragments were identified by peptide mass fingerprinting from mass spectrometric data and sequence analysis obtained by tandem mass spectrometry of the principal mass spectral peaks using a data-dependent scanning protocol. These data were compared with those from mass spectrometric analysis using capillary LC/MALDI-time-of-flight (TOF) and capillary LC/electrospray ionisation (ESI)-quadrupole TOF. For all three configurations the resulting data were searched against the MSDB database, using MASCOT and the sequence coverage compared for each technique. Complementary data were obtained using the three techniques.
Collapse
Affiliation(s)
- Colin S Creaser
- School of Biomedical and Natural Sciences, Nottingham Trent University, Nottingham NG11 8NS, UK.
| | | | | | | |
Collapse
|
15
|
Norbeck AD, Monroe ME, Adkins JN, Smith RD. The utility of accurate mass and LC elution time information in the analysis of complex proteomes. J Am Soc Mass Spectrom 2005; 16:1239-49. [PMID: 15979333 PMCID: PMC1769320 DOI: 10.1016/j.jasms.2005.05.009] [Citation(s) in RCA: 70] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2005] [Revised: 05/20/2005] [Accepted: 05/23/2005] [Indexed: 05/03/2023]
Abstract
The combination of mass and normalized elution time (NET) of a peptide identified by liquid chromatography-mass spectrometry (LC-MS) measurements can serve as a unique signature for that peptide. However, the specificity of an LC-MS measurement depends upon the complexity of the proteome (i.e., the number of possible peptides) and the accuracy of the LC-MS measurements. In this work, theoretical tryptic digests of all predicted proteins from the genomes of three organisms of varying complexity were evaluated for specificity. Accuracy of the LC-MS measurement of mass-NET pairs (on a 0 to 1.0 NET scale) was described by bivariate normal sampling distributions centered on the peptide signatures. Measurement accuracy (i.e., mass and NET standard deviations of +/-0.1, 1, 5, and 10 ppm, and +/-0.01 and 0.05, respectively) was varied to evaluate improvements in process quality. The spatially localized confidence score, a conditional probability of peptide uniqueness, formed the basis for the peptide identification. Application of this approach to organisms with comparatively small proteomes, such as Deinococcus radiodurans, shows that modest mass and elution time accuracies are generally adequate for confidently identifying most peptides. For more complex proteomes, more accurate measurements are required. However, the study suggests that the majority of proteins for even the human proteome should be identifiable with reasonable confidence by using LC-MS measurements with mass accuracies within +/-1 ppm and high efficiency separations having elution time measurements within +/-0.01 NET.
Collapse
Affiliation(s)
| | | | | | - Richard D. Smith
- Address reprint requests to: Richard D. Smith, Pacific Northwest National Laboratories, P.O. Box 999, MSIN: K8-98, Richland, Washington 99352, Phone: 509-376-0723, Fax: 509-376-7722,
| |
Collapse
|
16
|
Abstract
Shotgun proteomics has emerged as a powerful approach for the analysis of complex protein mixtures, including biofluids, tissues, cells, organelles or protein complexes. Having evolved from the integration of chromatography and mass spectrometry, innovations in sample preparation, multidimensional chromatography, mass spectrometry and proteomic informatics continually facilitate, enable and challenge shotgun proteomics. As a result, shotgun proteomics continues to evolve and enable new areas of biological research, and is beginning to impact human disease diagnosis and therapeutic intervention.
Collapse
Affiliation(s)
- Selene K Swanson
- Stowers Institute for Medical Research, 1000 E. 50th St., Kansas City, MO 64110, USA
| | | |
Collapse
|
17
|
Current Awareness on Comparative and Functional Genomics. Comp Funct Genomics 2005; 6:185-192. [DOI: 10.1002/cfg.420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|