1
|
Lohr MJ, Sugerman GP, Kakaletsis S, Lejeune E, Rausch MK. An introduction to the Ogden model in biomechanics: benefits, implementation tools and limitations. Philos Trans A Math Phys Eng Sci 2022. [PMID: 36031838 DOI: 10.6084/m9.figshare.c.6098644] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Constitutive models are important to biomechanics for two key reasons. First, constitutive modelling is an essential component of characterizing tissues' mechanical properties for informing theoretical and computational models of biomechanical systems. Second, constitutive models can be used as a theoretical framework for extracting and comparing key quantities of interest from material characterization experiments. Over the past five decades, the Ogden model has emerged as a popular constitutive model in soft tissue biomechanics with relevance to both informing theoretical and computational models and to comparing material characterization experiments. The goal of this short review is threefold. First, we will discuss the broad relevance of the Ogden model to soft tissue biomechanics and the general characteristics of soft tissues that are suitable for approximating with the Ogden model. Second, we will highlight exemplary uses of the Ogden model in brain tissue, blood clot and other tissues. Finally, we offer a tutorial on fitting the one-term Ogden model to pure shear experimental data via both an analytical approximation of homogeneous deformation and a finite-element model of the tissue domain. Overall, we anticipate that this short review will serve as a practical introduction to the use of the Ogden model in biomechanics. This article is part of the theme issue 'The Ogden model of rubber mechanics: Fifty years of impact on nonlinear elasticity'.
Collapse
Affiliation(s)
- Matthew J Lohr
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, USA
| | - Gabriella P Sugerman
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, USA
| | - Sotirios Kakaletsis
- Department of Aerospace Engineering and Engineering Mechanics, University of Texas at Austin, Austin, TX, USA
| | - Emma Lejeune
- Department of Mechanical Engineering, Boston University, Boston, MA, USA
| | - Manuel K Rausch
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, USA
- Department of Aerospace Engineering and Engineering Mechanics, University of Texas at Austin, Austin, TX, USA
- Oden Institute for Computational Engineering and Sciences, University of Texas at Austin, Austin, TX, USA
| |
Collapse
|
2
|
Lohr MJ, Sugerman GP, Kakaletsis S, Lejeune E, Rausch MK. An introduction to the Ogden model in biomechanics: benefits, implementation tools and limitations. Philos Trans A Math Phys Eng Sci 2022; 380:20210365. [PMID: 36031838 PMCID: PMC9784101 DOI: 10.1098/rsta.2021.0365] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Accepted: 03/14/2022] [Indexed: 05/04/2023]
Abstract
Constitutive models are important to biomechanics for two key reasons. First, constitutive modelling is an essential component of characterizing tissues' mechanical properties for informing theoretical and computational models of biomechanical systems. Second, constitutive models can be used as a theoretical framework for extracting and comparing key quantities of interest from material characterization experiments. Over the past five decades, the Ogden model has emerged as a popular constitutive model in soft tissue biomechanics with relevance to both informing theoretical and computational models and to comparing material characterization experiments. The goal of this short review is threefold. First, we will discuss the broad relevance of the Ogden model to soft tissue biomechanics and the general characteristics of soft tissues that are suitable for approximating with the Ogden model. Second, we will highlight exemplary uses of the Ogden model in brain tissue, blood clot and other tissues. Finally, we offer a tutorial on fitting the one-term Ogden model to pure shear experimental data via both an analytical approximation of homogeneous deformation and a finite-element model of the tissue domain. Overall, we anticipate that this short review will serve as a practical introduction to the use of the Ogden model in biomechanics. This article is part of the theme issue 'The Ogden model of rubber mechanics: Fifty years of impact on nonlinear elasticity'.
Collapse
Affiliation(s)
- Matthew J. Lohr
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, USA
| | - Gabriella P. Sugerman
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, USA
| | - Sotirios Kakaletsis
- Department of Aerospace Engineering and Engineering Mechanics, University of Texas at Austin, Austin, TX, USA
| | - Emma Lejeune
- Department of Mechanical Engineering, Boston University, Boston, MA, USA
| | - Manuel K. Rausch
- Department of Biomedical Engineering, University of Texas at Austin, Austin, TX, USA
- Department of Aerospace Engineering and Engineering Mechanics, University of Texas at Austin, Austin, TX, USA
- Oden Institute for Computational Engineering and Sciences, University of Texas at Austin, Austin, TX, USA
| |
Collapse
|
3
|
Arm R, Shahidi A, Clarke C, Alabraba E. Synthesis and characterisation of a cancerous liver for presurgical planning and training applications. BMJ Open Gastroenterol 2022; 9:e000909. [PMID: 35853677 PMCID: PMC9301799 DOI: 10.1136/bmjgast-2022-000909] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Accepted: 06/27/2022] [Indexed: 11/29/2022] Open
Abstract
OBJECTIVES Oncology surgeons use animals and cadavers in training because of a lack of alternatives. The aim of this work was to develop a design methodology to create synthetic liver models familiar to surgeons, and to help plan, teach and rehearse patient-specific cancerous liver resection surgery. DESIGN Synthetic gels were selected and processed to recreate accurate anthropomorphic qualities. Organic and synthetic materials were mechanically tested with the same equipment and standards to determine physical properties like hardness, elastic modulus and viscoelasticity. Collected data were compared with published data on the human liver. Patient-specific CT data were segmented and reconstructed and additive manufactured models were made of the liver vasculature, parenchyma and lesion. Using toolmaking and dissolvable scaffolds, models were transformed into tactile duplicates that could mimic liver tissue behaviour. RESULTS Porcine liver tissue hardness was found to be 23 H00 (±0.1) and synthetic liver was 10 H00 (±2.3), while human parenchyma was reported as 15.06 H00 (±2.64). Average elastic Young's modulus of human liver was reported as 0.012 MPa, and synthetic liver was 0.012 MPa, but warmed porcine parenchyma was 0.28 MPa. The final liver model demonstrated a time-dependant viscoelastic response to cyclic loading. CONCLUSION Synthetic liver was better than porcine liver at recreating the mechanical properties of living human liver. Warmed porcine liver was more brittle, less extensible and stiffer than both human and synthetic tissues. Qualitative surgical assessment of the model by a consultant liver surgeon showed vasculature was explorable and that bimanual palpation, organ delivery, transposition and organ slumping were analogous to human liver behaviour.
Collapse
Affiliation(s)
- Richard Arm
- School of Art and Design, Nottingham Trent University City Campus, Nottingham, UK
| | - Arash Shahidi
- School of Art and Design, Nottingham Trent University City Campus, Nottingham, UK
| | - Christopher Clarke
- Department of Radiology, Queens Medical Centre, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | - Edward Alabraba
- Department of Hepatobiliary and Pancreatic Surgery, Queen's Medical Centre, Nottingham University Hospitals NHS Trust, Nottingham, UK
| |
Collapse
|
4
|
Li Z, Chen Z, Gao Y, Xing Y, Zhou Y, Luo Y, Xu W, Chen Z, Gao X, Gupta K, Anbalakan K, Chen L, Liu C, Kong J, Leo HL, Hu C, Yu H, Guo Q. Shape memory micro-anchors with magnetic guidance for precision micro-vascular deployment. Biomaterials 2022; 283:121426. [DOI: 10.1016/j.biomaterials.2022.121426] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Revised: 01/21/2022] [Accepted: 02/17/2022] [Indexed: 12/28/2022]
|
5
|
Jushiddi MG, Mani A, Silien C, Tofail SA, Tiernan P, Mulvihill JJ. A computational multilayer model to simulate hollow needle insertion into biological porcine liver tissue. Acta Biomater 2021; 136:389-401. [PMID: 34624554 DOI: 10.1016/j.actbio.2021.09.057] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 08/27/2021] [Accepted: 09/29/2021] [Indexed: 11/25/2022]
Abstract
Modelling of needle insertion in soft tissue has developed significant interest in recent years due to its application in robot-assisted minimally invasive surgeries such as biopsies and brachytherapy. However, this type of surgery requires real-time feedback and processing which complex computational models may not be able to provide. In contrast to the existing mechanics-based kinetic models, a simple multilayer tissue model using a Coupled Eulerian Lagrangian based Finite Element method has been developed using the dynamic principle. The model simulates the needle motion for flexible hollow bevel-angled needle (15° and 30°, 22 Gauge) insertion into porcine liver tissue, which includes material parameters obtained from unconfined compression testing of porcine liver tissue. To validate simulation results, needle insertion force and cutting force within porcine liver tissue were compared with corresponding experimental results obtained from a custom-built needle insertion system. For the 15° and 30° bevel-angle needles, the percentage error for cutting force (mean) of each needle compared to computational model, were 18.7% and 11.9% respectively. Varying the needle bevel angle from 30° to 15° results in an increase of the cutting force, but insertion force does not vary among the tested bevel angles. The validation of this computationally efficient multilayer Finite Element model can help engineers to better understand the biomechanical behaviour of medical needle inside soft biological tissue. Ultimately, this multilayer approach can help advance state-of-art clinical applications such as robot-assisted surgery that requires real-time feedback and processing. STATEMENT OF SIGNIFICANCE: The significance of the work is in confirming the effectiveness of multilayer material based finite element (FE) method to model biopsy needle insertion into soft biological porcine liver tissue. A multilayer Coupled Eulerian Lagrangian (CEL) based FE modelling technique allowed testing of heterogeneous, non-linear viscoelastic porcine liver tissue in a system, so direct comparison of needle tissue interaction forces on the intrinsic material (tissue) behaviour could be made. To the best of the authors' knowledge, the present research investigates for the first time modelling of a three dimensional (3D) hollow needle insertion using a multilayer stiffness model of biological tissue using FE based CEL method and presents a comparison of simulation results with experimental data.
Collapse
|
6
|
Abstract
The mechanical properties of soft tissues play a key role in studying human injuries and their mitigation strategies. While such properties are indispensable for computational modelling of biological systems, they serve as important references in loading and failure experiments, and also for the development of tissue simulants. To date, experimental studies have measured the mechanical properties of peripheral tissues (e.g. skin)in-vivoand limited internal tissuesex-vivoin cadavers (e.g. brain and the heart). The lack of knowledge on a majority of human tissues inhibit their study for applications ranging from surgical planning, ballistic testing, implantable medical device development, and the assessment of traumatic injuries. The purpose of this work is to overcome such challenges through an extensive review of the literature reporting the mechanical properties of whole-body soft tissues from head to toe. Specifically, the available linear mechanical properties of all human tissues were compiled. Non-linear biomechanical models were also introduced, and the soft human tissues characterized using such models were summarized. The literature gaps identified from this work will help future biomechanical studies on soft human tissue characterization and the development of accurate medical models for the study and mitigation of injuries.
Collapse
Affiliation(s)
- Gurpreet Singh
- Centre for Biomedical Engineering, Indian Institute of Technology (IIT), Delhi, India
| | - Arnab Chanda
- Centre for Biomedical Engineering, Indian Institute of Technology (IIT), Delhi, India.,Department of Biomedical Engineering, All India Institute of Medical Sciences (AIIMS), Delhi, India
| |
Collapse
|
7
|
Aseni P, Santaniello T, Rizzetto F, Gentili L, Pezzotta F, Cavaliere F, Vertemati M, Milani P. Hybrid Additive Fabrication of a Transparent Liver with Biosimilar Haptic Response for Preoperative Planning. Diagnostics (Basel) 2021; 11:1734. [PMID: 34574075 PMCID: PMC8471167 DOI: 10.3390/diagnostics11091734] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 09/17/2021] [Accepted: 09/18/2021] [Indexed: 12/15/2022] Open
Abstract
Due to the complexity of liver surgery, the interest in 3D printing is constantly increasing among hepatobiliary surgeons. The aim of this study was to produce a patient-specific transparent life-sized liver model with tissue-like haptic properties by combining additive manufacturing and 3D moulding. A multistep pipeline was adopted to obtain accurate 3D printable models. Semiautomatic segmentation and registration of routine medical imaging using 3D Slicer software allowed to obtain digital objects representing the structures of interest (liver parenchyma, vasculo-biliary branching, and intrahepatic lesion). The virtual models were used as the source data for a hybrid fabrication process based on additive manufacturing using soft resins and casting of tissue-mimicking silicone-based blend into 3D moulds. The model of the haptic liver reproduced with high fidelity the vasculo-biliary branching and the relationship with the intrahepatic lesion embedded into the transparent parenchyma. It offered high-quality haptic perception and a remarkable degree of surgical and anatomical information. Our 3D transparent model with haptic properties can help surgeons understand the spatial changes of intrahepatic structures during surgical manoeuvres, optimising preoperative surgical planning.
Collapse
Affiliation(s)
- Paolo Aseni
- Department of Emergency, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore 3, 20162 Milano, Italy;
- Department of Biomedical and Clinical Sciences “L. Sacco”, Università degli Studi di Milano, Via Giovanni Battista Grassi 74, 20157 Milano, Italy
| | - Tommaso Santaniello
- Centro Interdisciplinare Materiali e Interfacce Nanostrutturati (CIMaINa), Università degli Studi di Milano, Via Celoria 16, 20133 Milano, Italy; (T.S.); (L.G.); (F.P.); (F.C.)
- Dipartimento di Fisica “A. Pontremoli”, Università degli Studi di Milano, Via Celoria 16, 20133 Milano, Italy
| | - Francesco Rizzetto
- Department of Radiology, ASST Grande Ospedale Metropolitano Niguarda, Piazza Ospedale Maggiore 3, 20162 Milano, Italy;
- Postgraduate School of Diagnostic and Interventional Radiology, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milano, Italy
| | - Lorenzo Gentili
- Centro Interdisciplinare Materiali e Interfacce Nanostrutturati (CIMaINa), Università degli Studi di Milano, Via Celoria 16, 20133 Milano, Italy; (T.S.); (L.G.); (F.P.); (F.C.)
- Dipartimento di Fisica “A. Pontremoli”, Università degli Studi di Milano, Via Celoria 16, 20133 Milano, Italy
| | - Federico Pezzotta
- Centro Interdisciplinare Materiali e Interfacce Nanostrutturati (CIMaINa), Università degli Studi di Milano, Via Celoria 16, 20133 Milano, Italy; (T.S.); (L.G.); (F.P.); (F.C.)
- Dipartimento di Fisica “A. Pontremoli”, Università degli Studi di Milano, Via Celoria 16, 20133 Milano, Italy
| | - Francesco Cavaliere
- Centro Interdisciplinare Materiali e Interfacce Nanostrutturati (CIMaINa), Università degli Studi di Milano, Via Celoria 16, 20133 Milano, Italy; (T.S.); (L.G.); (F.P.); (F.C.)
- Dipartimento di Fisica “A. Pontremoli”, Università degli Studi di Milano, Via Celoria 16, 20133 Milano, Italy
| | - Maurizio Vertemati
- Department of Biomedical and Clinical Sciences “L. Sacco”, Università degli Studi di Milano, Via Giovanni Battista Grassi 74, 20157 Milano, Italy
- Centro Interdisciplinare Materiali e Interfacce Nanostrutturati (CIMaINa), Università degli Studi di Milano, Via Celoria 16, 20133 Milano, Italy; (T.S.); (L.G.); (F.P.); (F.C.)
| | - Paolo Milani
- Centro Interdisciplinare Materiali e Interfacce Nanostrutturati (CIMaINa), Università degli Studi di Milano, Via Celoria 16, 20133 Milano, Italy; (T.S.); (L.G.); (F.P.); (F.C.)
- Dipartimento di Fisica “A. Pontremoli”, Università degli Studi di Milano, Via Celoria 16, 20133 Milano, Italy
| |
Collapse
|
8
|
Chang YJ, Benharash P, Dutson EP, Eldredge JD. Smoothed particle hydrodynamics simulation of biphasic soft tissue and its medical applications. Med Biol Eng Comput 2021; 59:227-242. [PMID: 33415698 DOI: 10.1007/s11517-020-02283-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Accepted: 10/26/2020] [Indexed: 12/27/2022]
Abstract
Modeling the coupled fluid and elastic mechanics of blood perfused soft tissues is important for medical applications. In particular, the current study aims to capture the effect of tissue swelling and the transport of blood through damaged tissue under bleeding or hemorrhaging conditions. The soft tissue is considered a dynamic poro-hyperelastic material with blood-filled voids. A biphasic formulation-effectively, a generalization of Darcy's law-is utilized, treating the phases as occupying fractions of the same volume. A Stokes-like friction force and a pressure that penalizes deviations from volume fractions summing to unity serve as the interaction force between solid and liquid phases. The resulting equations for both phases are discretized with the method of smoothed particle hydrodynamics (SPH). The solver is validated separately on each phase and demonstrates good agreement with exact solutions in test problems. Simulations of oozing, hysteresis, swelling, drying and shrinkage, and tissue fracturing and hemorrhage are shown in the paper. Graphical Abstract In the paper, a new methodology for the numerical simulation of the full dynamic response of blood-perfused soft tissues was developed.
Collapse
Affiliation(s)
- Yi-Jui Chang
- Mechanical and Aerospace Engineering Department, University of California, Los Angeles, CA, USA
| | - Peyman Benharash
- Department of Surgery, University of California, Los Angeles, CA, USA
| | - Erik P Dutson
- Department of Surgery, University of California, Los Angeles, CA, USA.,Center for Advanced Surgical and Interventional Technology, University of California, Los Angeles, CA, USA
| | - Jeff D Eldredge
- Mechanical and Aerospace Engineering Department, University of California, Los Angeles, CA, USA.
| |
Collapse
|
9
|
Worlikar T, Mendiratta-Lala M, Vlaisavljevich E, Hubbard R, Shi J, Hall TL, Cho CS, Lee FT, Greve J, Xu Z. Effects of Histotripsy on Local Tumor Progression in an in vivo Orthotopic Rodent Liver Tumor Model. BME Front 2020; 2020. [PMID: 34327513 PMCID: PMC8318009 DOI: 10.34133/2020/9830304] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Objective and Impact Statement This is the first longitudinal study investigating the effects of histotripsy on local tumor progression in an in vivo orthotopic, immunocompetent rat hepatocellular carcinoma (HCC) model. Introduction Histotripsy is the first noninvasive, nonionizing, nonthermal, mechanical ablation technique using ultrasound to generate acoustic cavitation to liquefy the target tissue into acellular debris with millimeter accuracy. Previously, histotripsy has demonstrated in vivo ablation of noncancerous liver tissue. Methods N1-S1 HCC tumors were generated in the livers of immunocompetent rats (n = 6, control; n = 15, treatment). Real-time ultrasound-guided histotripsy was applied to ablate either 100% tumor volume + up to 2mm margin (n = 9, complete treatment) or 50-75% tumor volume (n = 6, partial treatment) by delivering 1-2 cycle histotripsy pulses at 100 Hz PRF (pulse repetition frequency) with p - ≥30MPa using a custom 1MHz transducer. Rats were monitored weekly using MRI (magnetic resonance imaging) for 3 months or until tumors reached ~25mm. Results MRI revealed effective post-histotripsy reduction of tumor burden with near-complete resorption of the ablated tumor in 14/15 (93.3%) treated rats. Histopathology showed <5mm shrunken, non-tumoral, fibrous tissue at the treatment site at 3 months. Rats with increased tumor burden (3/6 control and 1 partial treatment) were euthanized early by 2-4 weeks. In 3 other controls, histology revealed fibrous tissue at original tumor site at 3 months. There was no evidence of histotripsy-induced off-target tissue injury. Conclusion Complete and partial histotripsy ablation resulted in effective tumor removal for 14/15 rats, with no evidence of local tumor progression or recurrence.
Collapse
Affiliation(s)
- Tejaswi Worlikar
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | | | - Eli Vlaisavljevich
- Department of Biomedical Engineering and Mechanics, Virginia Polytechnic Institute and State University, Blacksburg, Virginia 24061, USA
| | - Ryan Hubbard
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Jiaqi Shi
- Department of Pathology, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Timothy L Hall
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Clifford S Cho
- Department of Surgery, University of Michigan, Ann Arbor, Michigan 48109, USA.,Department of Surgery, VA Ann Arbor Healthcare System, Ann Arbor, Michigan 48105, USA
| | - Fred T Lee
- Department of Radiology, University of Wisconsin, Madison, Wisconsin 53705, USA
| | - Joan Greve
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| | - Zhen Xu
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan 48109, USA
| |
Collapse
|
10
|
Jung YH, Kim JU, Lee JS, Shin JH, Jung W, Ok J, Kim TI. Injectable Biomedical Devices for Sensing and Stimulating Internal Body Organs. Adv Mater 2020; 32:e1907478. [PMID: 32104960 DOI: 10.1002/adma.201907478] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Revised: 01/15/2020] [Indexed: 06/10/2023]
Abstract
The rapid pace of progress in implantable electronics driven by novel technology has created devices with unconventional designs and features to reduce invasiveness and establish new sensing and stimulating techniques. Among the designs, injectable forms of biomedical electronics are explored for accurate and safe targeting of deep-seated body organs. Here, the classes of biomedical electronics and tools that have high aspect ratio structures designed to be injected or inserted into internal organs for minimally invasive monitoring and therapy are reviewed. Compared with devices in bulky or planar formats, the long shaft-like forms of implantable devices are easily placed in the organs with minimized outward protrusions via injection or insertion processes. Adding flexibility to the devices also enables effortless insertions through complex biological cavities, such as the cochlea, and enhances chronic reliability by complying with natural body movements, such as the heartbeat. Diverse types of such injectable implants developed for different organs are reviewed and the electronic, optoelectronic, piezoelectric, and microfluidic devices that enable stimulations and measurements of site-specific regions in the body are discussed. Noninvasive penetration strategies to deliver the miniscule devices are also considered. Finally, the challenges and future directions associated with deep body biomedical electronics are explained.
Collapse
Affiliation(s)
- Yei Hwan Jung
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Jong Uk Kim
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Ju Seung Lee
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Joo Hwan Shin
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Woojin Jung
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Jehyung Ok
- School of Chemical Engineering, Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| | - Tae-Il Kim
- School of Chemical Engineering, Department of Biomedical Engineering, and Biomedical Institute for Convergence at SKKU (BICS), Sungkyunkwan University (SKKU), Suwon, 16419, Republic of Korea
| |
Collapse
|
11
|
Hashemi MS, Baniassadi M, Baghani M, George D, Remond Y, Sheidaei A. A novel machine learning based computational framework for homogenization of heterogeneous soft materials: application to liver tissue. Biomech Model Mechanobiol 2019; 19:1131-1142. [PMID: 31823106 DOI: 10.1007/s10237-019-01274-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2019] [Accepted: 11/29/2019] [Indexed: 10/25/2022]
Abstract
Real-time simulation of organs increases comfort and safety for patients during the surgery. Proper generalized decomposition (PGD) is an efficient numerical method with coordinate errors below 1 mm and response time below 0.1 s that can be used for simulated surgery. For input of this approach, nonlinear mechanical properties of each segment of the liver need to be calculated based on the geometries of the patient's liver extracted using medical imaging techniques. In this research work, a map of the mechanical properties of the liver tissue has been estimated with a novel combined method of the finite element (FE) optimization. Due to the existence of major-size vessels in the liver that makes the surrounding tissue anisotropic, the simulation of hyperelastic material with two different sections is computationally expensive. Thus, a homogenized, anisotropic, and hyperelastic model with the nearest response to the real heterogeneous model was developed and presented. Because of various possibilities of the vessel orientation, position, and size, homogenization has been carried out for adequate samples of heterogeneous models to train artificial neural networks (ANNs) as machine learning tools. Then, an unknown sample of heterogeneous material was categorized and mapped to its homogenized material parameters with the trained networks for the fast and low-cost generalization of our combined FE optimization method. The results showed the efficiency of the proposed novel machine learning based technique for the prediction of effective material properties of unknown heterogeneous tissues.
Collapse
Affiliation(s)
- Mohammad Saber Hashemi
- Department of Aerospace Engineering, Iowa State University, Ames, IA, USA
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Majid Baniassadi
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Mostafa Baghani
- School of Mechanical Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Daniel George
- Laboratoire ICube, University of Strasbourg, CNRS, Strasbourg, France
| | - Yves Remond
- Laboratoire ICube, University of Strasbourg, CNRS, Strasbourg, France
| | - Azadeh Sheidaei
- Department of Aerospace Engineering, Iowa State University, Ames, IA, USA.
| |
Collapse
|
12
|
Li L, Maccabi A, Abiri A, Juo YY, Zhang W, Chang YJ, Saddik GN, Jin L, Grundfest WS, Dutson EP, Eldredge JD, Benharash P, Candler RN. Characterization of perfused and sectioned liver tissue in a full indentation cycle using a visco-hyperelastic model. J Mech Behav Biomed Mater 2019; 90:591-603. [PMID: 30500697 DOI: 10.1016/j.jmbbm.2018.11.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2018] [Revised: 10/09/2018] [Accepted: 11/04/2018] [Indexed: 12/22/2022]
Abstract
Realistic modeling of biologic material is required for optimizing fidelity in computer-aided surgical training and assistance systems. The modeling of liver tissue has remained challenging due to its nonlinear viscoelastic properties and high hysteresis of the stress-strain relation. While prior studies have described the behavior of liver tissue during the loading status (in elongation, compression, or indentation tests) or unloading status (in stress relaxation or creep tests), a hysteresis curve with both loading and unloading processes was incompletely defined. We seek to use a single material model to characterize the mechanical properties of liver tissue in a full indentation cycle ex vivo perfused and then sectioned. Based on measurements taken from ex-vivo perfused porcine livers, we converted force-displacement curves to stress-strain curves and developed a visco-hyperelastic constitutive model to characterize the liver's mechanical behavior at different locations under various rates of indentation (1, 2, 5, 10, and 20 mm/s). The proposed model is a mixed visco-hyperelastic model with up to 6 coefficients. The normalized root mean square standard deviations of fitted curves are less than 5% and 10% in low (<0.05) and high strain (>0.3) conditions respectively.
Collapse
|
13
|
Quero G, Lapergola A, Soler L, Shahbaz M, Hostettler A, Collins T, Marescaux J, Mutter D, Diana M, Pessaux P. Virtual and Augmented Reality in Oncologic Liver Surgery. Surg Oncol Clin N Am 2018; 28:31-44. [PMID: 30414680 DOI: 10.1016/j.soc.2018.08.002] [Citation(s) in RCA: 50] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Virtual reality (VR) and augmented reality (AR) in complex surgery are evolving technologies enabling improved preoperative planning and intraoperative navigation. The basis of these technologies is a computer-based generation of a patient-specific 3-dimensional model from Digital Imaging and Communications in Medicine (DICOM) data. This article provides a state-of-the- art overview on the clinical use of this technology with a specific focus on hepatic surgery. Although VR and AR are still in an evolving stage with only some clinical application today, these technologies have the potential to become a key factor in improving preoperative and intraoperative decision making.
Collapse
Affiliation(s)
- Giuseppe Quero
- IHU-Strasbourg, Institute of Image-Guided Surgery, 1 Place de l'Hôpital, Strasbourg 67091, France
| | - Alfonso Lapergola
- IRCAD, Research Institute Against Cancer of the Digestive System, 1 Place de l'Hôpital, Strasbourg 67091, France
| | - Luc Soler
- IRCAD, Research Institute Against Cancer of the Digestive System, 1 Place de l'Hôpital, Strasbourg 67091, France
| | - Muhammad Shahbaz
- IHU-Strasbourg, Institute of Image-Guided Surgery, 1 Place de l'Hôpital, Strasbourg 67091, France
| | - Alexandre Hostettler
- IRCAD, Research Institute Against Cancer of the Digestive System, 1 Place de l'Hôpital, Strasbourg 67091, France
| | - Toby Collins
- IRCAD, Research Institute Against Cancer of the Digestive System, 1 Place de l'Hôpital, Strasbourg 67091, France
| | - Jacques Marescaux
- IHU-Strasbourg, Institute of Image-Guided Surgery, 1 Place de l'Hôpital, Strasbourg 67091, France; IRCAD, Research Institute Against Cancer of the Digestive System, 1 Place de l'Hôpital, Strasbourg 67091, France
| | - Didier Mutter
- Department of General, Digestive and Endocrine Surgery, University Hospital of Strasbourg, 1 Place de l'Hôpital, Strasbourg 67091, France
| | - Michele Diana
- IHU-Strasbourg, Institute of Image-Guided Surgery, 1 Place de l'Hôpital, Strasbourg 67091, France; IRCAD, Research Institute Against Cancer of the Digestive System, 1 Place de l'Hôpital, Strasbourg 67091, France; Department of General, Digestive and Endocrine Surgery, University Hospital of Strasbourg, 1 Place de l'Hôpital, Strasbourg 67091, France
| | - Patrick Pessaux
- IHU-Strasbourg, Institute of Image-Guided Surgery, 1 Place de l'Hôpital, Strasbourg 67091, France; IRCAD, Research Institute Against Cancer of the Digestive System, 1 Place de l'Hôpital, Strasbourg 67091, France; Department of General, Digestive and Endocrine Surgery, University Hospital of Strasbourg, 1 Place de l'Hôpital, Strasbourg 67091, France.
| |
Collapse
|
14
|
Worlikar T, Vlaisavljevich E, Gerhardson T, Greve J, Wan S, Kuruvilla S, Lundt J, Ives K, Hall T, Welling TH, Lee F, Xu Z. Histotripsy for Non-Invasive Ablation of Hepatocellular Carcinoma (HCC) Tumor in a Subcutaneous Xenograft Murine Model. Annu Int Conf IEEE Eng Med Biol Soc 2018; 2018:6064-6067. [PMID: 30441719 DOI: 10.1109/embc.2018.8513650] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Histotripsy fractionates tissue through a mechanical, non-invasive ultrasonic ablation process that precisely controls acoustic cavitation while utilizing real-time ultrasound (US) imaging guidance. This study investigates the potential, feasibility and tumor volume reduction effects of histotripsy for liver cancer ablation in a subcutaneous in vivo murine Hepatocellular Carcinoma (HCC) model. Hep3B tumors were generated in the right flanks of 14 NSG and 7 NOD-SCID mice. The mice were grouped as follows: A (acute, NSG with n=9 treatment and n=1 control), B (chronic, NSG with n=2 treatment and n=2 control) and C (chronic NODSCID, with n=6 treatment and n=1 control). Treatment was performed when the tumor diameters reached >5 mm. 1-2 cycle histotripsy pulses at 100 Hz PRF (p- >30 MPa) were delivered using a custom built 1 MHz therapy transducer attached to a motorized positioner, which scanned the transducer focus to traverse the targeted tumor volume, guided by real-time US imaging. Tumor ablation effectiveness was assessed by obtaining T1, T2 and T2* weighted MR images. Post euthanasia, treated tumor, brain, and lung tissue samples were harvested for histology. Histology of acute group A showed fractionation of targeted region with a sharp boundary separating it from untreated tissue. Groups B and C demonstrated effective tumor volume reduction post treatment on MRI as the homogenate and edema were resorbed within 23 weeks. However, as the tumor was subcutaneous, it was not possible to set adequate treatment margin and since the mice were immune-compromised, residual viable tumor cells eventually developed into tumor regrowth at 3-9 weeks after histotripsy. Groups B and C showed no signs of metastasis in the lung and brain. Our study successfully demonstrated the potential of histotripsy for non-invasive HCC ablation in a subcutaneous murine model. Additional work is ongoing to study the response of histotripsy in immune-competent orthotopic liver tumor models.
Collapse
|
15
|
Plantefève R, Peterlik I, Cotin S. Intraoperative Biomechanical Registration of the Liver: Does the Heterogeneity of the Liver Matter? Ing Rech Biomed 2018. [DOI: 10.1016/j.irbm.2017.10.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
16
|
Bircher K, Ehret AE, Mazza E. Microstructure based prediction of the deformation behavior of soft collagenous membranes. Soft Matter 2017; 13:5107-5116. [PMID: 28492654 DOI: 10.1039/c7sm00101k] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
The response of human amnion (HA) and bovine Glisson's capsule (GC) to uniaxial and biaxial tensile loading is analyzed on tissue (∼mm) and collagen fiber (∼μm) length scales. The mechanical behavior of the membranes is rationalized based on a discrete fiber network model that relates model parameters with microstructural features of the tissues. Parameters were first determined for GC based on the quantity and organization of collagen fibers in the tissue. Next, parameters for HA were defined by comparing the microstructures of the two membranes, which differ in fiber organization in that collagen forms μm-thick fiber bundles in GC while 50 nm-thin fibrils constitute the network in HA. The flexural behavior of these structures is phenomenologically represented in the model, indicating that shear forces are transmitted through fibrils within GC bundles, but to a much lesser extent than in a corresponding solid cross section. The model provides excellent predictions of the uniaxial and biaxial mechanical response, as well as of the progressive reorientation of fibers associated with uniaxial loading. The results are particularly relevant since model parameters were not obtained through a fitting procedure of the tissue's tension-stretch curve. Furthermore, simulations of representative in vivo deformation states indicated that a large part of the fibers are expected to be un-crimped under physiological loading conditions. Thus, the crimped shape of collagen fibers in the initial test configuration, and typically observed in histological analyses, might be a consequence of the contraction occurring when membranes are extracted from their environment in the body.
Collapse
Affiliation(s)
- Kevin Bircher
- Institute for Mechanical Systems, ETH Zurich, 8092 Zurich, Switzerland.
| | | | | |
Collapse
|
17
|
Abstract
Minimally invasive surgery is slowly taking over as the preferred operative approach for colorectal diseases. However, many of the procedures remain technically difficult. This article will give an overview of the state of minimally invasive surgery and the many advances that have been made over the last two decades. Specifically, we discuss the introduction of the robotic platform and some of its benefits and limitations. We also describe some newer techniques related to robotics.
Collapse
Affiliation(s)
- Matthew Whealon
- Department of Surgery, University of California, Irvine, Orange, California
| | - Alessio Vinci
- Department of Surgery, University of California, Irvine, Orange, California
| | - Alessio Pigazzi
- Department of Surgery, University of California, Irvine, Orange, California
| |
Collapse
|
18
|
Diana M, Schiraldi L, Liu YY, Memeo R, Mutter D, Pessaux P, Marescaux J. High intensity focused ultrasound (HIFU) applied to hepato-bilio-pancreatic and the digestive system-current state of the art and future perspectives. Hepatobiliary Surg Nutr 2016; 5:329-44. [PMID: 27500145 DOI: 10.21037/hbsn.2015.11.03] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
BACKGROUND High intensity focused ultrasound (HIFU) is emerging as a valid minimally-invasive image-guided treatment of malignancies. We aimed to review to current state of the art of HIFU therapy applied to the digestive system and discuss some promising avenues of the technology. METHODS Pertinent studies were identified through PubMed and Embase search engines using the following keywords, combined in different ways: HIFU, esophagus, stomach, liver, pancreas, gallbladder, colon, rectum, and cancer. Experimental proof of the concept of endoluminal HIFU mucosa/submucosa ablation using a custom-made transducer has been obtained in vivo in the porcine model. RESULTS Forty-four studies reported on the clinical use of HIFU to treat liver lesions, while 19 series were found on HIFU treatment of pancreatic cancers and four studies included patients suffering from both liver and pancreatic cancers, reporting on a total of 1,682 and 823 cases for liver and pancreas, respectively. Only very limited comparative prospective studies have been reported. CONCLUSIONS Digestive system clinical applications of HIFU are limited to pancreatic and liver cancer. It is safe and well tolerated. The exact place in the hepatocellular carcinoma (HCC) management algorithm remains to be defined. HIFU seems to add clear survival advantages over trans arterial chemo embolization (TACE) alone and similar results when compared to radio frequency (RF). For pancreatic cancer, HIFU achieves consistent cancer-related pain relief. Further research is warranted to improve targeting accuracy and efficacy monitoring. Furthermore, additional work is required to transfer this technology on appealing treatments such as endoscopic HIFU-based therapies.
Collapse
Affiliation(s)
- Michele Diana
- IRCAD, Research Institute Against Cancer of the Digestive System, Strasbourg, France;; IHU-Strasbourg, Institute for Image-Guided Surgery, Strasbourg, France
| | - Luigi Schiraldi
- IRCAD, Research Institute Against Cancer of the Digestive System, Strasbourg, France
| | - Yu-Yin Liu
- IRCAD, Research Institute Against Cancer of the Digestive System, Strasbourg, France;; Department of General Surgery, Chang Gung Memorial Hospital, Linkou, Chang Gung University, Taoyuan, Taiwan
| | - Riccardo Memeo
- IHU-Strasbourg, Institute for Image-Guided Surgery, Strasbourg, France;; Department of Digestive Surgery, University Hospital of Strasbourg, France
| | - Didier Mutter
- IRCAD, Research Institute Against Cancer of the Digestive System, Strasbourg, France;; Department of Digestive Surgery, University Hospital of Strasbourg, France
| | - Patrick Pessaux
- IHU-Strasbourg, Institute for Image-Guided Surgery, Strasbourg, France;; Department of Digestive Surgery, University Hospital of Strasbourg, France
| | - Jacques Marescaux
- IRCAD, Research Institute Against Cancer of the Digestive System, Strasbourg, France;; IHU-Strasbourg, Institute for Image-Guided Surgery, Strasbourg, France
| |
Collapse
|
19
|
Bircher K, Ehret AE, Mazza E. Mechanical Characteristics of Bovine Glisson's Capsule as a Model Tissue for Soft Collagenous Membranes. J Biomech Eng 2016; 138:2530163. [DOI: 10.1115/1.4033917] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Indexed: 01/19/2023]
Abstract
An extensive multiaxial experimental campaign on the monotonic, time- and history-dependent mechanical response of bovine Glisson's capsule (GC) is presented. Reproducible characteristics were observed such as J-shaped curves in uniaxial and biaxial configurations, large lateral contraction, cyclic tension softening, large tension relaxation, and moderate creep strain accumulation. The substantial influence of the reference state selection on the kinematic response and the tension versus stretch curves is demonstrated and discussed. The parameters of a large-strain viscoelastic constitutive model were determined based on the data of uniaxial tension relaxation experiments. The model is shown to well predict the uniaxial and biaxial viscoelastic responses in all other configurations. GC, the corresponding model, and the experimental protocols are proposed as a useful basis for future studies on the relation between microstructure and tissue functionality and on the factors influencing the mechanical response of soft collagenous membranes.
Collapse
Affiliation(s)
- Kevin Bircher
- Institute for Mechanical Systems, ETH Zurich, Zurich 8092, Switzerland e-mail:
| | - Alexander E. Ehret
- Institute for Mechanical Systems, ETH Zurich, Zurich 8092, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland e-mail:
| | - Edoardo Mazza
- Institute for Mechanical Systems, ETH Zurich, Zurich 8092, Switzerland; Empa, Swiss Federal Laboratories for Materials Science and Technology, Dübendorf 8600, Switzerland e-mail:
| |
Collapse
|
20
|
Rodger MP, Theobald P, Giddins G. Vein grafts to augment flexor tendon repairs: a biomechanical study on strength and gap resistance. J Hand Surg Eur Vol 2015; 40:695-9. [PMID: 25541551 DOI: 10.1177/1753193414564902] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Accepted: 11/22/2014] [Indexed: 02/03/2023]
Abstract
The ultimate tensile repair strength and gap formation of the pig extensor tendons repaired with a standard 4-strand Savage with epitendinous suture repair, was compared with a new technique of adding a vein sleeve. Force and displacement data were recorded, and video images during linear cyclic loading up to failure. At 35 N, video-graphic observation detected significantly smaller gap lengths in the standard and vein repair specimens compared with standard repair specimens (p = 0.047). The incidence of 3 mm gaps between the repaired tendon ends in the standard repair group was 20 %, but no 3 mm gaps were seen in the standard and vein specimens. The addition of a vein sleeve increased the ultimate tensile strength of the standard repair from 50.4 N (4.5) to 55.4 N (4.5); this was statistically significant (p = 0.03). This study demonstrated that the addition of a vein graft prevented gap formation and increased ultimate tensile strength of tendon repair.
Collapse
Affiliation(s)
- M P Rodger
- School of Engineering, Cardiff University, Cardiff, UK
| | - P Theobald
- School of Engineering, Cardiff University, Cardiff, UK
| | - G Giddins
- Department of Mechanical Engineering, University of Bath, Bath, UK
| |
Collapse
|
21
|
Ayyildiz M, Cinoglu S, Basdogan C. Effect of normal compression on the shear modulus of soft tissue in rheological measurements. J Mech Behav Biomed Mater 2015; 49:235-43. [DOI: 10.1016/j.jmbbm.2015.05.011] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2015] [Revised: 05/02/2015] [Accepted: 05/13/2015] [Indexed: 11/24/2022]
|
22
|
Plantefève R, Peterlik I, Haouchine N, Cotin S. Patient-Specific Biomechanical Modeling for Guidance During Minimally-Invasive Hepatic Surgery. Ann Biomed Eng 2016; 44:139-53. [DOI: 10.1007/s10439-015-1419-z] [Citation(s) in RCA: 79] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2015] [Accepted: 08/05/2015] [Indexed: 11/26/2022]
|
23
|
Chebil O, Arnoux PJ, Behr M. Mechanical characterization of human gastrocolic ligament until failure. J Appl Biomater Funct Mater 2015; 13:e106-15. [PMID: 24756780 DOI: 10.5301/jabfm.5000193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/09/2013] [Indexed: 11/20/2022] Open
Abstract
Road accidents can lead to abdominal injuries ranging from severe to lethal, that include hemorrhage of organs and their attachment system. A good understanding and prediction of abdominal injuries therefore requires investigation of the mechanical properties of the attachment systems of abdominal organs. In particular, the gastrocolic ligament (GCL) is one major link between the stomach and the transverse colon. This study aims to investigate the mechanical properties of the GCL under very low and high strain rate uniaxial tensile tests until failure. Thirty-five GCL samples were dissected from 7 embalmed cadavers and tested at a rate of 1 mm/s and 1 m/s. Incidence of freezing was also evaluated. The mechanical response of GCL samples showed an approximately bilinear curve. Within the first linear region (less than 5% of ligament strain), the apparent elastic modulus was estimated at 247±144 kPa, while in the second region, it was estimated at 690±282 kPa. The average failure stress (σfail) and failure strain (εfail) were 131.6±50 kPa and 29%±8%, respectively. High strain rate loading also showed high sensitivity to strain rate. The estimated GCL mechanical properties in this study can be implemented in finite element models of the abdomen to further investigate the mechanical contribution of the organ attachment system under traumatic loading conditions.
Collapse
|
24
|
Haouchine N, Cotin S, Peterlik I, Dequidt J, Lopez MS, Kerrien E, Berger MO. Impact of Soft Tissue Heterogeneity on Augmented Reality for Liver Surgery. IEEE Trans Vis Comput Graph 2015; 21:584-597. [PMID: 26357206 DOI: 10.1109/tvcg.2014.2377772] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This paper presents a method for real-time augmented reality of internal liver structures during minimally invasive hepatic surgery. Vessels and tumors computed from pre-operative CT scans can be overlaid onto the laparoscopic view for surgery guidance. Compared to current methods, our method is able to locate the in-depth positions of the tumors based on partial three-dimensional liver tissue motion using a real-time biomechanical model. This model permits to properly handle the motion of internal structures even in the case of anisotropic or heterogeneous tissues, as it is the case for the liver and many anatomical structures. Experimentations conducted on phantom liver permits to measure the accuracy of the augmentation while real-time augmentation on in vivo human liver during real surgery shows the benefits of such an approach for minimally invasive surgery.
Collapse
|
25
|
Abstract
BACKGROUND Proficiency in minimally invasive surgery requires intensive and continuous training, as it is technically challenging for unnatural visual and haptic perceptions. Robotic and computer sciences are producing innovations to augment the surgeon's skills to achieve accuracy and high precision during complex surgery. This article reviews the current use of robotically assisted surgery, focusing on technology as well as main applications in digestive surgery, and future perspectives. METHODS The PubMed database was interrogated to retrieve evidence-based data on surgical applications. Internal and external consulting with key opinion leaders, renowned robotics laboratories and robotic platform manufacturers was used to produce state-of-the art business intelligence around robotically assisted surgery. RESULTS Selected digestive procedures (oesophagectomy, gastric bypass, pancreatic and liver resections, rectal resection for cancer) might benefit from robotic assistance, although the current level of evidence is insufficient to support widespread adoption. The surgical robotic market is growing, and a variety of projects have recently been launched at both academic and corporate levels to develop lightweight, miniaturized surgical robotic prototypes. CONCLUSION The magnified view, and improved ergonomics and dexterity offered by robotic platforms, might facilitate the uptake of minimally invasive procedures. Image guidance to complement robotically assisted procedures, through the concepts of augmented reality, could well represent a major revolution to increase safety and deal with difficulties associated with the new minimally invasive approaches.
Collapse
Affiliation(s)
- M Diana
- Research Institute Against Cancer of the Digestive System (IRCAD), European Institute of TeleSurgery (EITS) and International Institute for Image-Guided Surgery (IHU Strasbourg), Strasbourg, France
| | | |
Collapse
|
26
|
Abstract
Surgery, interventional radiology, and advanced endoscopy have all developed minimally invasive techniques to effectively treat a variety of diseases with positive impact on patients' postoperative outcomes. However, those techniques are challenging and require extensive training. Robotics and computer sciences can help facilitate minimally invasive approaches. Furthermore, surgery, advanced endoscopy, and interventional radiology could converge towards a new hybrid specialty, hybrid image-guided minimally invasive therapies, in which the three fundamental disciplines could complement one another to maximize the positive effects and reduce the iatrogenic footprint on patients. The present manuscript describes the fundamental steps of this new paradigm shift in surgical therapies that, in our opinion, will be the next revolutionary step in minimally invasive approaches.
Collapse
|
27
|
Wex C, Arndt S, Stoll A, Bruns C, Kupriyanova Y. Isotropic incompressible hyperelastic models for modelling the mechanical behaviour of biological tissues: a review. ACTA ACUST UNITED AC 2015; 60:577-92. [DOI: 10.1515/bmt-2014-0146] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2014] [Accepted: 05/07/2015] [Indexed: 11/15/2022]
Abstract
AbstractModelling the mechanical behaviour of biological tissues is of vital importance for clinical applications. It is necessary for surgery simulation, tissue engineering, finite element modelling of soft tissues, etc. The theory of linear elasticity is frequently used to characterise biological tissues; however, the theory of nonlinear elasticity using hyperelastic models, describes accurately the nonlinear tissue response under large strains. The aim of this study is to provide a review of constitutive equations based on the continuum mechanics approach for modelling the rate-independent mechanical behaviour of homogeneous, isotropic and incompressible biological materials. The hyperelastic approach postulates an existence of the strain energy function – a scalar function per unit reference volume, which relates the displacement of the tissue to their corresponding stress values. The most popular form of the strain energy functions as Neo-Hookean, Mooney-Rivlin, Ogden, Yeoh, Fung-Demiray, Veronda-Westmann, Arruda-Boyce, Gent and their modifications are described and discussed considering their ability to analytically characterise the mechanical behaviour of biological tissues. The review provides a complete and detailed analysis of the strain energy functions used for modelling the rate-independent mechanical behaviour of soft biological tissues such as liver, kidney, spleen, brain, breast, etc.
Collapse
|
28
|
Marescaux J, Diana M, Soler L. Application of a Three-Dimensional Print of a Liver in Hepatectomy for Small Tumors Invisible by Intraoperative Ultrasonography: Preliminary Experience. World J Surg 2014. [DOI: 10.1007/s00268-014-2825-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
29
|
|
30
|
Bosman J, Haouchine N, Dequidt J, Peterlik I, Cotin S, Duriez C. The Role of Ligaments: Patient-Specific or Scenario-Specific? Biomedical Simulation 2014. [DOI: 10.1007/978-3-319-12057-7_26] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
|
31
|
|
32
|
Jayyosi C, Coret M, Bruyère-Garnier K. Imaging of the human Glisson's capsule by two-photon excitation microscopy and mechanical characterisation by uniaxial tensile tests. Comput Methods Biomech Biomed Engin 2013; 16 Suppl 1:282-3. [PMID: 23923943 DOI: 10.1080/10255842.2013.815869] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Affiliation(s)
- C Jayyosi
- Université de Lyon, F-69622 Lyon, France.
| | | | | |
Collapse
|
33
|
Tan K, Cheng S, Jugé L, Bilston LE. Characterising soft tissues under large amplitude oscillatory shear and combined loading. J Biomech 2013; 46:1060-6. [PMID: 23481421 DOI: 10.1016/j.jbiomech.2013.01.028] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2012] [Revised: 01/15/2013] [Accepted: 01/31/2013] [Indexed: 10/27/2022]
Abstract
Characterising soft biological tissues outside the linear viscoelastic regime is challenging due to their complex behaviour. In addition, the viscoelastic properties of tissues have been shown to be sensitive to sample preparation and loading regime resulting in inconsistent data varying by orders magnitude in the literature. This paper presents a novel technique to characterise the non-linear behaviour of tissues which uses Fourier Transformation to decompose the stress output waveform under large amplitude oscillatory shear (LAOS) into harmonic contributions. The effect of varying preload, the compressive strain exerted on a liver tissue specimen prior to shear testing to minimise slip, was also investigated. Results showed that in the linear regime, preload affects the viscoelastic response of liver. Histological analysis indicated that there were structural changes as a result of the preload that may be linked to the differences in observed behaviour. Fourier analysis was used to extract the first and third harmonic components of the shear moduli at large strain. At 50% shear strain, a change in the third harmonic component of the shear moduli was accompanied by a marked change in the micro-structural arrangement of the sinusoids. This paper demonstrates a method of efficiently characterising soft biological tissues under large amplitude oscillatory shear under combined loading.
Collapse
Affiliation(s)
- Kristy Tan
- Graduate School of Biomedical Engineering, UNSW, Australia
| | | | | | | |
Collapse
|
34
|
Umale S, Deck C, Bourdet N, Dhumane P, Soler L, Marescaux J, Willinger R. Experimental mechanical characterization of abdominal organs: liver, kidney & spleen. J Mech Behav Biomed Mater 2012; 17:22-33. [PMID: 23127642 DOI: 10.1016/j.jmbbm.2012.07.010] [Citation(s) in RCA: 89] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Revised: 07/10/2012] [Accepted: 07/27/2012] [Indexed: 01/21/2023]
Abstract
Abdominal organs are the most vulnerable body parts during vehicle trauma, leading to high mortality rate due to acute injuries of liver, kidney, spleen and other abdominal organs. Accurate mechanical properties and FE models of these organs are required for simulating the traumas, so that better designing of the accident environment can be done and the organs can be protected from severe damage. Also from biomedical aspect, accurate mechanical properties of organs are required for better designing of surgical tools and virtual surgery environments. In this study porcine liver, kidney and spleen tissues are studied in vitro and hyper-elastic material laws are provided for each. 12 porcine kidneys are used to perform 40 elongation tests on renal capsule and 60 compression tests on renal cortex, 5 porcine livers are used to perform 45 static compression tests on liver parenchyma and 5 porcine spleens are used to carry out 20 compression tests. All the tests are carried out at a static speed of 0.05 mm/s. A comparative analysis of all the results is done with the literature and though the results are of same order of magnitude, a slight dissonance is observed for the renal capsule. It is also observed that the spleen is the least stiff organ in the abdomen whereas the kidney is the stiffest. The results of this study would be essential to develop the FE models of liver, kidney and spleen which can be further used for impact biomechanical and biomedical applications.
Collapse
Affiliation(s)
- Sagar Umale
- Institut de Mécanique des Fluides et des Solides, UNISTRA-CNRS, Strasbourg, France
| | | | | | | | | | | | | |
Collapse
|
35
|
Peterlík I, Duriez C, Cotin S. Modeling and Real-Time Simulation of a Vascularized Liver Tissue. Medical Image Computing and Computer-Assisted Intervention – MICCAI 2012 2012. [DOI: 10.1007/978-3-642-33415-3_7] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|