1
|
Razavi MS, Ruscic KJ, Korn EG, Marquez M, Houle TT, Singhal D, Munn LL, Padera TP. A Multiresolution Approach with Method-Informed Statistical Analysis for Quantifying Lymphatic Pumping Dynamics. bioRxiv 2024:2024.04.24.590950. [PMID: 38712181 PMCID: PMC11071510 DOI: 10.1101/2024.04.24.590950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2024]
Abstract
Despite significant strides in lymphatic system imaging, the timely diagnosis of lymphatic disorders remains elusive. One main cause for this is the absence of standardized, quantitative methods for real-time analysis of lymphatic contractility. Here, we address this unmet need by combining near-infrared lymphangiography imaging with an innovative analytical workflow. We combined data acquisition, signal processing, and statistical analysis to integrate traditional peak and-valley with advanced wavelet time-frequency analyses. Decision theory was used to evaluate the primary drivers of attributable variance in lymphangiography measurements to generate a strategy for optimizing the number of repeat measurements needed per subject to increase measurement reliability. This approach not only offers detailed insights into lymphatic pumping behaviors across species, sex and age, but also significantly boosts the reliability of these measurements by incorporating multiple regions of interest and evaluating the lymphatic system under various gravitational loads. By addressing the critical need for improved imaging and quantification methods, our study offers a new standard approach for the imaging and analysis of lymphatic function that can improve our understanding, diagnosis, and treatment of lymphatic diseases. The results highlight the importance of comprehensive data acquisition strategies to fully capture the dynamic behavior of the lymphatic system.
Collapse
|
2
|
Abstract
The lymphatics maintain fluid balance by returning interstitial fluid to veins via contraction/compression of vessel segments with check valves. Disruption of lymphatic pumping can result in a condition called lymphedema with interstitial fluid accumulation. Lymphedema treatments are often ineffective, which is partially attributable to insufficient understanding of specialized lymphatic muscle lining the vessels. This muscle exhibits cardiac-like phasic contractions and smooth muscle-like tonic contractions to generate and regulate flow. To understand the relationship between this sub-cellular contractile machinery and organ-level pumping, we have developed a multiscale computational model of phasic and tonic contractions in lymphatic muscle and coupled it to a lymphangion pumping model. Our model uses the sliding filament model (Huxley in Prog Biophys Biophys Chem 7:255-318, 1957) and its adaptation for smooth muscle (Mijailovich in Biophys J 79(5):2667-2681, 2000). Multiple structural arrangements of contractile components and viscoelastic elements were trialed but only one provided physiologic results. We then coupled this model with our previous lumped parameter model of the lymphangion to relate results to experiments. We show that the model produces similar pressure, diameter, and flow tracings to experiments on rat mesenteric lymphatics. This model provides the first estimates of lymphatic muscle contraction energetics and the ability to assess the potential effects of sub-cellular level phenomena such as calcium oscillations on lymphangion outflow. The maximum efficiency value predicted (40%) is at the upper end of estimates for other muscle types. Spontaneous calcium oscillations during diastole were found to increase outflow up to approximately 50% in the range of frequencies and amplitudes tested.
Collapse
Affiliation(s)
- Christopher J Morris
- Department of Bioengineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK
| | - David C Zawieja
- College of Medicine Faculty, Texas A&M University, Texas, USA
| | - James E Moore
- Department of Bioengineering, Imperial College London, South Kensington Campus, London, SW7 2AZ, UK.
| |
Collapse
|
3
|
Abstract
Using numerical simulations, we probe the fluid flow in an axisymmetric peristaltic vessel fitted with elastic bi-leaflet valves. In this biomimetic system that mimics the flow generated in lymphatic vessels, we investigate the effects of the valve and vessel properties on pumping performance of the valved peristaltic vessel. The results indicate that valves significantly increase pumping by reducing backflow. The presence of valves, however, increases the viscous resistance therefore requiring greater work compared to valveless vessels. The benefit of the valves is the most significant when the fluid is pumped against an adverse pressure gradient and for low vessel contraction wave speeds. We identify the optimum vessel and valve parameters leading to the maximum pumping efficiency. We show that the optimum valve elasticity maximizes the pumping flow rate by allowing the valve to block more effectively the backflow while maintaining low resistance during the forward flow. We also examine the pumping in vessels where the vessel contraction amplitude is a function of the adverse pressure gradient as found in lymphatic vessels. We find that in this case the flow is limited by the work generated by the contracting vessel, suggesting that the pumping in lymphatic vessels is constrained by the performance of lymphatic muscle. Given the regional heterogeneity of valve morphology observed throughout the lymphatic vasculature, these results provide insight into how these variations might facilitate efficient lymphatic transport in the vessel's local physiologic context.
Collapse
Affiliation(s)
- Ki Tae Wolf
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332
| | - J. Brandon Dixon
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332
- Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA 30332
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332
| | - Alexander Alexeev
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332
| |
Collapse
|
4
|
Solari E, Marcozzi C, Negrini D, Moriondo A. Lymphatic Vessels and Their Surroundings: How Local Physical Factors Affect Lymph Flow. Biology (Basel) 2020; 9:biology9120463. [PMID: 33322476 PMCID: PMC7763507 DOI: 10.3390/biology9120463] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/07/2020] [Revised: 12/02/2020] [Accepted: 12/09/2020] [Indexed: 12/16/2022]
Abstract
Simple Summary Lymphatic vessels are responsible for the drainage of liquids, solutes, and cells from interstitial spaces and serosal cavities. Their task is fundamental in order to avoid fluid accumulation leading to tissue swelling and edema. The lymphatic system does not possess a central pump, instead lymph is propelled against an overall hydraulic pressure gradient from interstitial spaces to central veins thanks to two pumping mechanisms, which rely on extrinsic forces or the intrinsic rhythmic contractility of lymphatic muscle cells embedded in vessel walls. This latter mechanism can very rapidly adapt to subtle changes in the microenvironment due to hydraulic pressure, lymph flow-induced wall shear stress, liquid osmolarity, and local tissue temperature. Thus, endothelial and lymphatic muscle cells possess mechanosensors that sense these stimuli and promote a change in contraction frequency and amplitude to modulate lymph flow accordingly. In this review, we will focus on the known physical parameters that can modulate lymph flow and on their putative cellular and molecular mechanisms of transduction. Abstract Lymphatic vessels drain and propel lymph by exploiting external forces that surrounding tissues exert upon vessel walls (extrinsic mechanism) and by using active, rhythmic contractions of lymphatic muscle cells embedded in the vessel wall of collecting lymphatics (intrinsic mechanism). The latter mechanism is the major source of the hydraulic pressure gradient where scant extrinsic forces are generated in the microenvironment surrounding lymphatic vessels. It is mainly involved in generating pressure gradients between the interstitial spaces and the vessel lumen and between adjacent lymphatic vessels segments. Intrinsic pumping can very rapidly adapt to ambient physical stimuli such as hydraulic pressure, lymph flow-derived shear stress, fluid osmolarity, and temperature. This adaptation induces a variable lymph flow, which can precisely follow the local tissue state in terms of fluid and solutes removal. Several cellular systems are known to be sensitive to osmolarity, temperature, stretch, and shear stress, and some of them have been found either in lymphatic endothelial cells or lymphatic muscle. In this review, we will focus on how known physical stimuli affect intrinsic contractility and thus lymph flow and describe the most likely cellular mechanisms that mediate this phenomenon.
Collapse
|
5
|
Abstract
Cholestatic liver disease affects millions of people worldwide and stems from a plethora of causes such as immune dysfunction, genetics, cancerous growths, and lifestyle choices. While not considered a classical lymphatic organ, the liver plays a vital role in the lymph system producing up to half of the body's lymph per day. The lymphatic system is critical to the health of an organism with its networks of vessels that provide drainage for lymphatic fluid and routes for surveilling immune cells. Cholestasis results in an increase of inflammatory cytokines, growth factors, and inflammatory infiltrate. Left unchecked, further disease progression will include collagen deposition which impedes both the hepatic and lymphatic ducts, eventually resulting in an increase in hepatic decompensation, increasing portal pressures, and accumulation of fluid within the abdominal cavity (ascites). Despite the documented interplay between these vital systems, little is known about the effect of liver disease on the lymph system and its biological response. This review looks at the current cholestatic literature from the perspective of the lymphatic system and summarizes what is known about the role of the lymph system in liver pathogenesis during hepatic injury and remodeling, immune-modulating events, or variations in interstitial pressures.
Collapse
Affiliation(s)
- April O’Brien
- Department of Medical Physiology, College of Medicine, Texas A&M University, Bryan, Texas
| | - Olga Gasheva
- Department of Medical Physiology, College of Medicine, Texas A&M University, Bryan, Texas
| | - Gianfranco Alpini
- Department of Medicine, Division of Gastroenterology, Richard L. Roudebush VA Medical Center, Indiana University School of Medicine, Indianapolis, Indiana,Department of Medicine, Division of Gastroenterology and Hepatology, Indiana University School of Medicine, Indianapolis, Indiana
| | - David Zawieja
- Department of Medical Physiology, College of Medicine, Texas A&M University, Bryan, Texas
| | - Anatoliy Gashev
- Department of Medical Physiology, College of Medicine, Texas A&M University, Bryan, Texas
| | - Shannon Glaser
- Department of Medical Physiology, College of Medicine, Texas A&M University, Bryan, Texas
| |
Collapse
|
6
|
Razavi MS, Dixon JB, Gleason RL. Characterization of rat tail lymphatic contractility and biomechanics: incorporating nitric oxide-mediated vasoregulation. J R Soc Interface 2020; 17:20200598. [PMID: 32993429 DOI: 10.1098/rsif.2020.0598] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
The lymphatic system transports lymph from the interstitial space back to the great veins via a series of orchestrated contractions of chains of lymphangions. Biomechanical models of lymph transport, validated with ex vivo or in vivo experimental results, have proved useful in revealing novel insight into lymphatic pumping; however, a need remains to characterize the contributions of vasoregulatory compounds in these modelling tools. Nitric oxide (NO) is a key mediator of lymphatic pumping. We quantified the active contractile and passive biaxial biomechanical response of rat tail collecting lymphatics and changes in the contractile response to the exogenous NO administration and integrated these findings into a biomechanical model. The passive mechanical response was characterized with a three-fibre family model. Nonlinear regression and non-parametric bootstrapping were used to identify best-fit material parameters to passive cylindrical biaxial mechanical data, assessing uniqueness and parameter confidence intervals; this model yielded a good fit (R2 = 0.90). Exogenous delivery of NO via sodium nitroprusside (SNP) elicited a dose-dependent suppression of contractions; the amplitude of contractions decreased by 30% and the contraction frequency decreased by 70%. Contractile function was characterized with a modified Rachev-Hayashi model, introducing a parameter that is related to SNP concentration; the model provided a good fit (R2 = 0.89) to changes in contractile responses to varying concentrations of SNP. These results demonstrated the significant role of NO in lymphatic pumping and provide a predictive biomechanical model to integrate the combined effect of mechanical loading and NO on lymphatic contractility and mechanical response.
Collapse
Affiliation(s)
- Mohammad S Razavi
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801 Ferst Drive, Atlanta, GA 30313, USA
| | - J Brandon Dixon
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801 Ferst Drive, Atlanta, GA 30313, USA.,Wallace H. Coulter Department of Biomedical Engineering, 313 Ferst Drive, Atanta, GA 30332, USA.,Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, 315 Ferst Drive, Atlanta, GA 30332, USA
| | - Rudolph L Gleason
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801 Ferst Drive, Atlanta, GA 30313, USA.,Wallace H. Coulter Department of Biomedical Engineering, 313 Ferst Drive, Atanta, GA 30332, USA.,Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, 315 Ferst Drive, Atlanta, GA 30332, USA
| |
Collapse
|
7
|
Razavi MS, Leonard-Duke J, Hardie B, Dixon JB, Gleason RL. Axial stretch regulates rat tail collecting lymphatic vessel contractions. Sci Rep 2020; 10:5918. [PMID: 32246026 PMCID: PMC7125298 DOI: 10.1038/s41598-020-62799-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2019] [Accepted: 03/19/2020] [Indexed: 01/07/2023] Open
Abstract
Lymphatic contractions play a fundamental role in maintaining tissue and organ homeostasis. The lymphatic system relies on orchestrated contraction of collecting lymphatic vessels, via lymphatic muscle cells and one-way valves, to transport lymph from the interstitial space back to the great veins, against an adverse pressure gradient. Circumferential stretch is known to regulate contractile function in collecting lymphatic vessels; however, less is known about the role of axial stretch in regulating contraction. It is likely that collecting lymphatic vessels are under axial strain in vivo and that the opening and closing of lymphatic valves leads to significant changes in axial strain throughout the pumping cycle. The purpose of this paper is to quantify the responsiveness of lympatic pumping to altered axial stretch. In situ measurements suggest that rat tail collecting lymphatic vessels are under an axial stretch of ~1.24 under normal physiological loads. Ex vivo experiments on isolated rat tail collecting lymphatics showed that the contractile metrics such as contractile amplitude, frequency, ejection fraction, and fractional pump flow are sensitive to axial stretch. Multiphoton microscopy showed that the predominant orientation of collagen fibers is in the axial direction, while lymphatic muscle cell nuclei and actin fibers are oriented in both circumferential and longitudinal directions, suggesting an axial component to contraction. Taken together, these results demonstrate the significance of axial stretch in lymphatic contractile function, suggest that axial stretch may play an important role in regulating lymph transport, and demonstrate that changes in axial strains could be an important factor in disease progression.
Collapse
Affiliation(s)
- Mohammad S Razavi
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801 Ferst Dr., Atlanta, GA, 30332, USA
| | - Julie Leonard-Duke
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, 313 Ferst Dr., Atlanta, GA, 30332, USA
| | - Becky Hardie
- The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, 313 Ferst Dr., Atlanta, GA, 30332, USA
| | - J Brandon Dixon
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801 Ferst Dr., Atlanta, GA, 30332, USA.,The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, 313 Ferst Dr., Atlanta, GA, 30332, USA.,The Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, 315 Ferst Dr., Atlanta, GA, 30332, USA
| | - Rudolph L Gleason
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801 Ferst Dr., Atlanta, GA, 30332, USA. .,The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, 313 Ferst Dr., Atlanta, GA, 30332, USA. .,The Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, 315 Ferst Dr., Atlanta, GA, 30332, USA.
| |
Collapse
|
8
|
Varkhede N, Bommana R, Schöneich C, Forrest ML. Proteolysis and Oxidation of Therapeutic Proteins After Intradermal or Subcutaneous Administration. J Pharm Sci 2020; 109:191-205. [PMID: 31408633 PMCID: PMC6937400 DOI: 10.1016/j.xphs.2019.08.005] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2019] [Revised: 08/05/2019] [Accepted: 08/06/2019] [Indexed: 12/12/2022]
Abstract
The intradermal (ID) and subcutaneous (SC) routes are commonly used for therapeutic proteins (TPs) and vaccines; however, the bioavailability of TPs is typically less than small molecule drugs given via the same routes. Proteolytic enzymes in the dermal, SC, and lymphatic tissues may be responsible for the loss of TPs. In addition, the TPs may be exposed to reactive oxygen species generated in the SC tissue and the lymphatic system in response to injection-related trauma and impurities within the formulation. The reactive oxygen species can oxidize TPs to alter their efficacy and immunogenicity potential. Mechanistic understandings of the dominant proteolysis and oxidative routes are useful in the drug discovery process, formulation development, and to assess the potential for immunogenicity and altered pharmacokinetics (PK). Furthermore, in vitro tools representing the ID or SC and lymphatic system can be used to evaluate the extent of proteolysis of the TPs after the injection and before systemic entry. The in vitro clearance data may be included in physiologically based pharmacokinetic models for improved PK predictions. In this review, we have summarized various physiological factors responsible for proteolysis and oxidation of TPs after ID and SC administration.
Collapse
Affiliation(s)
- Ninad Varkhede
- Department of Pharmaceutical Chemistry, The University of Kansas, Lawrence, Kansas 66047; Department of Pharmacokinetics, Pharmacodynamics & Drug Metabolism (PPDM), Merck Research Laboratories, West Point, Pennsylvania 19486
| | - Rupesh Bommana
- Department of Pharmaceutical Chemistry, The University of Kansas, Lawrence, Kansas 66047; MedImmune, Gaithersburg, Maryland 20878
| | - Christian Schöneich
- Department of Pharmaceutical Chemistry, The University of Kansas, Lawrence, Kansas 66047
| | - M Laird Forrest
- Department of Pharmaceutical Chemistry, The University of Kansas, Lawrence, Kansas 66047.
| |
Collapse
|
9
|
Bertram CD, Macaskill C, Moore JE. Inhibition of contraction strength and frequency by wall shear stress in a single-lymphangion model. J Biomech Eng 2019; 141:2733771. [PMID: 31074761 DOI: 10.1115/1.4043724] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Indexed: 12/29/2022]
Abstract
The phasic contractions of collecting lymphatic vessels are reduced in strength and occur at diminished frequency when the favourable pressure difference and the resulting antegrade flow create large fluid shear stresses at the luminal surface. This paper describes a minimal phenomenological model of this mechanism, that is applied to a previously validated numerical model of a phasically contracting lymphangion. The parameters of the inhibition model are quantitatively matched to observations in isolated segments of rat lymphatic vessel, first for mesenteric lymphatics then for thoracic duct, and outcomes from the numerical model are then qualitatively compared with recent observations in isolated segments of rat thoracic duct.
Collapse
Affiliation(s)
- C D Bertram
- School of Mathematics & Statistics, University of Sydney, New South Wales, Australia 2006
| | - Charles Macaskill
- School of Mathematics & Statistics, University of Sydney, New South Wales, Australia 2006
| | - James E Moore
- Department of Bioengineering, Imperial College London, London SW7 2AZ, United Kingdom
| |
Collapse
|
10
|
Hooks JST, Clement CC, Nguyen HD, Santambrogio L, Dixon JB. In vitro model reveals a role for mechanical stretch in the remodeling response of lymphatic muscle cells. Microcirculation 2018; 26:e12512. [PMID: 30383330 DOI: 10.1111/micc.12512] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2018] [Revised: 10/12/2018] [Accepted: 10/29/2018] [Indexed: 12/17/2022]
Abstract
OBJECTIVE Using primary LMCs in vitro, we sought to characterize the impact of LMC remodeling on their functional and molecular response to mechanical loading and culture conditions. METHODS Primary "wounded leg" LMCs were derived from the hindlimb of three sheep who underwent lymphatic injury 6 weeks prior, while "control leg" LMCs were derived from the contralateral, unwounded, limb. Function of the LMCs was characterized in response to media of variable levels of serum (10% vs 0.2%) and glucose (4.5 vs 1 g/L). Functional and proteomic data were evaluated in LMCs exposed to cyclic stretch (0.1 Hz, 7.5% elongation) for 1 week. RESULTS LMCs were sensitive to changes in serum levels, significantly reducing overall activity and collagen synthesis under low serum conditions. LMCs from the remodeled vessel had higher baseline levels of metabolic activity but not collagen synthesis. Cyclic loading induced cellular alignment perpendicular to the axis of stretch and alterations in signaling pathways associated with metabolism. Remodeled LMCs had consistently higher levels of metabolic activity and were more resistant to strain-induced apoptosis. CONCLUSIONS LMCs exist on a functional spectrum, becoming more active in response to stretching and maintaining phenotypic remodeling in response to local lymphatic/tissue damage.
Collapse
Affiliation(s)
- Joshua S T Hooks
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia.,George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Cristina C Clement
- Department of Pathology, Albert Einstein College of Medicine, Bronx, New York
| | - Hoang-Dung Nguyen
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia.,Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia
| | - Laura Santambrogio
- Department of Pathology, Albert Einstein College of Medicine, Bronx, New York
| | - J Brandon Dixon
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, Georgia.,George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia.,Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia
| |
Collapse
|
11
|
Ballard M, Wolf KT, Nepiyushchikh Z, Dixon JB, Alexeev A. Probing the effect of morphology on lymphatic valve dynamic function. Biomech Model Mechanobiol 2018; 17:1343-56. [DOI: 10.1007/s10237-018-1030-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2017] [Accepted: 05/10/2018] [Indexed: 12/19/2022]
|
12
|
Nizamutdinova IT, Dusio GF, Gasheva OY, Skoog H, Tobin R, Peddaboina C, Meininger CJ, Zawieja DC, Newell-Rogers MK, Gashev AA. Mast cells and histamine are triggering the NF-κB-mediated reactions of adult and aged perilymphatic mesenteric tissues to acute inflammation. Aging (Albany NY) 2017; 8:3065-3090. [PMID: 27875806 PMCID: PMC5191886 DOI: 10.18632/aging.101113] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2016] [Accepted: 11/08/2016] [Indexed: 12/29/2022]
Abstract
This study aimed to establish mechanistic links between the aging-associated changes in the functional status of mast cells and the altered responses of mesenteric tissue and mesenteric lymphatic vessels (MLVs) to acute inflammation. We used an in vivo model of acute peritoneal inflammation induced by lipopolysaccharide treatment of adult (9-month) and aged (24-month) F-344 rats. We analyzed contractility of isolated MLVs, mast cell activation, activation of nuclear factor-κB (NF-κB) without and with stabilization of mast cells by cromolyn or blockade of all types of histamine receptors and production of 27 major pro-inflammatory cytokines in adult and aged perilymphatic mesenteric tissues and blood. We found that the reactivity of aged contracting lymphatic vessels to LPS-induced acute inflammation was abolished and that activated mast cells trigger NF-κB signaling in the mesentery through release of histamine. The aging-associated basal activation of mesenteric mast cells limits acute inflammatory NF-κB activation in aged mesentery. We conclude that proper functioning of the mast cell/histamine/NF-κB axis is necessary for reactions of the lymphatic vessels to acute inflammatory stimuli as well as for interaction and trafficking of immune cells near and within the collecting lymphatics.
Collapse
Affiliation(s)
- Irina Tsoy Nizamutdinova
- Department of Medical Physiology, College of Medicine, Texas A&M University Health Science Center, Temple, TX 76504, USA
| | - Giuseppina F Dusio
- Department of Surgery, Baylor Scott and White Health, Texas A&M University Health Science Center, Temple, TX 76504, USA
| | - Olga Yu Gasheva
- Department of Medical Physiology, College of Medicine, Texas A&M University Health Science Center, Temple, TX 76504, USA
| | - Hunter Skoog
- Department of Medical Physiology, College of Medicine, Texas A&M University Health Science Center, Temple, TX 76504, USA
| | - Richard Tobin
- Department of Surgery, Baylor Scott and White Health, Texas A&M University Health Science Center, Temple, TX 76504, USA
| | - Chander Peddaboina
- Department of Surgery, Baylor Scott and White Health, Texas A&M University Health Science Center, Temple, TX 76504, USA
| | - Cynthia J Meininger
- Department of Medical Physiology, College of Medicine, Texas A&M University Health Science Center, Temple, TX 76504, USA
| | - David C Zawieja
- Department of Medical Physiology, College of Medicine, Texas A&M University Health Science Center, Temple, TX 76504, USA
| | - M Karen Newell-Rogers
- Department of Surgery, Baylor Scott and White Health, Texas A&M University Health Science Center, Temple, TX 76504, USA
| | - Anatoliy A Gashev
- Department of Medical Physiology, College of Medicine, Texas A&M University Health Science Center, Temple, TX 76504, USA
| |
Collapse
|
13
|
Razavi MS, Nelson TS, Nepiyushchikh Z, Gleason RL, Dixon JB. The relationship between lymphangion chain length and maximum pressure generation established through in vivo imaging and computational modeling. Am J Physiol Heart Circ Physiol 2017; 313:H1249-H1260. [PMID: 28778909 DOI: 10.1152/ajpheart.00003.2017] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
The intrinsic contraction of collecting lymphatic vessels serves as a pumping system to propel lymph against hydrostatic pressure gradients as it returns interstitial fluid to the venous circulation. In the present study, we proposed and validated that the maximum opposing outflow pressure along a chain of lymphangions at which flow can be achieved increases with the length of chain. Using minimally invasive near-infrared imaging to measure the effective pumping pressure at various locations in the rat tail, we demonstrated increases in pumping pressure along the length of the tail. Computational simulations based on a microstructurally motivated model of a chain of lymphangions informed from biaxial testing of isolated vessels was used to provide insights into the pumping mechanisms responsible for the pressure increases observed in vivo. These models suggest that the number of lymphangions in the chain and smooth muscle cell force generation play a significant role in determining the maximum outflow pressure, whereas the frequency of contraction has no effect. In vivo administration of nitric oxide attenuated lymphatic contraction, subsequently lowering the effective pumping pressure. Computational simulations suggest that the reduction in contractile strength of smooth muscle cells in the presence of nitric oxide can account for the reductions in outflow pressure observed along the lymphangion chain in vivo. Thus, combining modeling with multiple measurements of lymphatic pumping pressure provides a method for approximating intrinsic lymphatic muscle activity noninvasively in vivo while also providing insights into factors that determine the extent that a lymphangion chain can transport fluid against an adverse pressure gradient. NEW & NOTEWORTHY Here, we report the first minimally invasive in vivo measurements of the relationship between lymphangion chain length and lymphatic pumping pressure. We also provide the first in vivo validation of lumped parameter models of lymphangion chains previously developed through data obtained from isolated vessel testing.
Collapse
Affiliation(s)
- Mohammad S Razavi
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology , Atlanta, Georgia.,The Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology , Atlanta, Georgia
| | - Tyler S Nelson
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology , Atlanta, Georgia.,The Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology , Atlanta, Georgia
| | - Zhanna Nepiyushchikh
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology , Atlanta, Georgia.,The Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology , Atlanta, Georgia
| | - Rudolph L Gleason
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology , Atlanta, Georgia.,The Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology , Atlanta, Georgia.,The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology , Atlanta, Georgia
| | - J Brandon Dixon
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology , Atlanta, Georgia.,The Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology , Atlanta, Georgia.,The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology , Atlanta, Georgia
| |
Collapse
|
14
|
Abstract
The lymphatic system is responsible for transporting interstitial fluid back to the bloodstream, but unlike the cardiovascular system, lacks a centralized pump-the heart–to drive flow. Instead, each collecting lymphatic vessel can individually contract and dilate producing unidirectional flow enforced by intraluminal check valves. Due to the large number and spatial distribution of such pumps, high-level coordination would be unwieldy. This leads to the question of how each segment of lymphatic vessel responds to local signals that can contribute to the coordination of pumping on a network basis. Beginning with elementary fluid mechanics and known cellular behaviors, we show that two complementary oscillators emerge from i) mechanical stretch with calcium ion transport and ii) fluid shear stress induced nitric oxide production (NO). Using numerical simulation and linear stability analysis we show that the newly identified shear-NO oscillator shares similarities with the well-known Van der Pol oscillator, but has unique characteristics. Depending on the operating conditions, the shear-NO process may i) be inherently stable, ii) oscillate spontaneously in response to random disturbances or iii) synchronize with weak periodic stimuli. When the complementary shear-driven and stretch-driven oscillators interact, either may dominate, producing a rich family of behaviors similar to those observed in vivo. For decades, cardiovascular physiology has been an area of intense research, and we have a fundamental understanding of the mechanisms the heart uses to drive blood flow through the distributed network of vessels in the body. The lymphatic system is now receiving similar attention as more is learned about its functional role in disease processes. The importance of the lymphatic system in collecting excess fluid from tissues and returning it to the blood is well known, but how the lymph flow is regulated without a central pump is poorly understood. Each segment of collecting lymphatic vessel can independently contract yielding a network of distributed pump/conduits. This paper shows how the lymphatic muscle cells that squeeze fluid along the lymphatic vessels can be effectively regulated using only chemical and mechanical signals that they receive from their immediate microenvironment. Using stability theory and the tools of nonlinear dynamics we identify two complementary oscillators that respond to stretch of the vessel wall and shear of fluid flowing over the vessel wall. Numerical simulations of the combined oscillators show that they have characteristics well suited to the regulation of distributed systems in general and may have application in other biological and physical contexts.
Collapse
Affiliation(s)
- James W. Baish
- Department of Biomedical Engineering, Bucknell University, Lewisburg, Pennsylvania, United States of America
- * E-mail:
| | - Christian Kunert
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, United States of America
- AMGEN, Cambridge, Massachusetts, United States of America
| | - Timothy P. Padera
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, United States of America
| | - Lance L. Munn
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, United States of America
| |
Collapse
|
15
|
Bertram CD, Macaskill C, Moore JE Jr. Pump function curve shape for a model lymphatic vessel. Med Eng Phys 2016; 38:656-63. [PMID: 27185045 DOI: 10.1016/j.medengphy.2016.04.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Revised: 03/08/2016] [Accepted: 04/08/2016] [Indexed: 11/23/2022]
Abstract
The transport capacity of a contractile segment of lymphatic vessel is defined by its pump function curve relating mean flow-rate and adverse pressure difference. Numerous system characteristics affect curve shape and the magnitude of the generated flow-rates and pressures. Some cannot be varied experimentally, but their separate and interacting effects can be systematically revealed numerically. This paper explores variations in the rate of change of active tension and the form of the relation between active tension and muscle length, factors not known from experiment to functional precision. Whether the pump function curve bends toward or away from the origin depends partly on the curvature of the passive pressure-diameter relation near zero transmural pressure, but rather more on the form of the relation between active tension and muscle length. A pump function curve bending away from the origin defines a well-performing pump by maximum steady output power. This behaviour is favoured by a length/active-tension relationship which sustains tension at smaller lengths. Such a relationship also favours high peak mechanical efficiency, defined as output power divided by the input power obtained from the lymphangion diameter changes and active-tension time-course. The results highlight the need to pin down experimentally the form of the length/active-tension relationship.
Collapse
|
16
|
Kassis T, Yarlagadda SC, Kohan AB, Tso P, Breedveld V, Dixon JB. Postprandial lymphatic pump function after a high-fat meal: a characterization of contractility, flow, and viscosity. Am J Physiol Gastrointest Liver Physiol 2016; 310:G776-89. [PMID: 26968208 PMCID: PMC4888550 DOI: 10.1152/ajpgi.00318.2015] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2015] [Accepted: 03/04/2016] [Indexed: 01/31/2023]
Abstract
Dietary lipids are transported from the intestine through contractile lymphatics. Chronic lipid loads can adversely affect lymphatic function. However, the acute lymphatic pump response in the mesentery to a postprandial lipid meal has gone unexplored. In this study, we used the rat mesenteric collecting vessel as an in vivo model to quantify the effect of lipoproteins on vessel function. Lipid load was continuously monitored by using the intensity of a fluorescent fatty-acid analog, which we infused along with a fat emulsion through a duodenal cannula. The vessel contractility was simultaneously quantified. We demonstrated for the first time that collecting lymphatic vessels respond to an acute lipid load by reducing pump function. High lipid levels decreased contraction frequency and amplitude. We also showed a strong tonic response through a reduction in the end-diastolic and systolic diameters. We further characterized the changes in flow rate and viscosity and showed that both increase postprandially. In addition, shear-mediated Ca(2+) signaling in lymphatic endothelial cells differed when cultured with lipoproteins. Together these results show that the in vivo response could be both shear and lipid mediated and provide the first evidence that high postprandial lipid has an immediate negative effect on lymphatic function even in the acute setting.
Collapse
Affiliation(s)
- Timothy Kassis
- 1Parker H. Petit Institute for Bioengineering & Bioscience, Georgia Institute of Technology, Atlanta, Georgia; ,2School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia;
| | - Sri Charan Yarlagadda
- 4School of Chemical & Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia; and
| | - Alison B. Kohan
- 5Department of Pathology and Laboratory Medicine, University of Cincinnati, Cincinnati, Ohio
| | - Patrick Tso
- 5Department of Pathology and Laboratory Medicine, University of Cincinnati, Cincinnati, Ohio
| | - Victor Breedveld
- 4School of Chemical & Biomolecular Engineering, Georgia Institute of Technology, Atlanta, Georgia; and
| | - J. Brandon Dixon
- 1Parker H. Petit Institute for Bioengineering & Bioscience, Georgia Institute of Technology, Atlanta, Georgia; ,3George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia;
| |
Collapse
|
17
|
Caulk AW, Nepiyushchikh ZV, Shaw R, Dixon JB, Gleason RL. Quantification of the passive and active biaxial mechanical behaviour and microstructural organization of rat thoracic ducts. J R Soc Interface 2016; 12:20150280. [PMID: 26040600 DOI: 10.1098/rsif.2015.0280] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
Abstract
Mechanical loading conditions are likely to play a key role in passive and active (contractile) behaviour of lymphatic vessels. The development of a microstructurally motivated model of lymphatic tissue is necessary for quantification of mechanically mediated maladaptive remodelling in the lymphatic vasculature. Towards this end, we performed cylindrical biaxial testing of Sprague-Dawley rat thoracic ducts (n = 6) and constitutive modelling to characterize their mechanical behaviour. Spontaneous contraction was quantified at transmural pressures of 3, 6 and 9 cmH2O. Cyclic inflation in calcium-free saline was performed at fixed axial stretches between 1.30 and 1.60, while recording pressure, outer diameter and axial force. A microstructurally motivated four-fibre family constitutive model originally proposed by Holzapfel et al. (Holzapfel et al. 2000 J. Elast. 61, 1-48. (doi:10.1023/A:1010835316564)) was used to quantify the passive mechanical response, and the model of Rachev and Hayashi was used to quantify the active (contractile) mechanical response. The average error between data and theory was 8.9 ± 0.8% for passive data and 6.6 ± 2.6% and 6.8 ± 3.4% for the systolic and basal conditions, respectively, for active data. Multi-photon microscopy was performed to quantify vessel wall thickness (32.2 ± 1.60 µm) and elastin and collagen organization for three loading conditions. Elastin exhibited structural 'fibre families' oriented nearly circumferentially and axially. Sample-to-sample variation was observed in collagen fibre distributions, which were often non-axisymmetric, suggesting material asymmetry. In closure, this paper presents a microstructurally motivated model that accurately captures the biaxial active and passive mechanical behaviour in lymphatics and offers potential for future research to identify parameters contributing to mechanically mediated disease development.
Collapse
Affiliation(s)
- Alexander W Caulk
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Zhanna V Nepiyushchikh
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - Ryan Shaw
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA
| | - J Brandon Dixon
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA The Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA, USA
| | - Rudolph L Gleason
- The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, USA The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA, USA The Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA, USA
| |
Collapse
|
18
|
Mizuno R, Isshiki M, Ono N, Nishimoto M, Fujita T. A High-Salt Diet Differentially Modulates Mechanical Activity of Afferent and Efferent Collecting Lymphatics in Murine Iliac Lymph Nodes. Lymphat Res Biol 2015; 13:85-92. [PMID: 26091404 DOI: 10.1089/lrb.2014.0043] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND The lymphatic system contributes to fluid homeostasis in various tissues. Recent evidence suggests that lymphangiogenesis induced by a high-salt diet (HSD) is associated with blood pressure regulation. Lymph nodes, located along lymphatic pathways, are not only important secondary lymphoid tissues for cancer metastasis, inflammation, and immune responses, but are also important for fluid homeostasis. Afferent lymphatics collect lymph from the pre-nodal area and efferent lymphatics drain lymph out of the lymph nodes. However, the difference in mechanical activity between afferent and efferent lymphatics and the effect of a HSD on these vessels have not been shown. METHODS AND RESULTS Changes in mechanical activity of isolated afferent and efferent lymphatics in normal salt diet (NSD) and 4-week HSD mice in response to increases in intraluminal pressures from 3 to 7 cmH2O were measured using video-microscopy. The higher intramural pressure equivalently decreased pumping activity of afferent and efferent lymphatics in NSD mice. A HSD suppressed the amplitude, ejection fraction, and stroke volume of afferent lymphatics, leading to marked reductions in pumping activity. In contrast, the pumping activities of efferent lymphatics were resistant to a HSD and were preserved by enhancing the contraction frequency. CONCLUSIONS A HSD differentially modulated the mechanical activity of afferent and efferent collecting lymphatics in murine iliac lymph nodes.
Collapse
Affiliation(s)
- Risuke Mizuno
- 1 Department of Veterinary Pharmacology, Graduate School of Agriculture and Life Sciences, The University of Tokyo , Tokyo, Japan .,2 Department of Molecular Vascular Endocrinology, Graduate School of Medicine, The University of Tokyo , Tokyo, Japan
| | - Masashi Isshiki
- 3 Department of Endocrinology and Diabetes, School of Medicine, Saitama Medical University, Saitama, Japan
| | - Nobuyuki Ono
- 4 Department of Electronics and Control Engineering, Nagano National College of Technology , Nagano, Japan
| | - Mitsuhiro Nishimoto
- 5 Division of Clinical Epigenetics, Research Center for Advanced Science and Technology, The University of Tokyo , Tokyo, Japan
| | - Toshiro Fujita
- 4 Department of Electronics and Control Engineering, Nagano National College of Technology , Nagano, Japan
| |
Collapse
|
19
|
Abstract
The lymphatic system is responsible for controlling tissue fluid pressure by facilitating flow of lymph (i.e. the plasma and cells that enter the lymphatic system). Because lymph contains cells of the immune system, its transport is not only important for fluid homeostasis, but also immune function. Lymph drainage can occur via passive flow or active pumping, and much research has identified the key biochemical and mechanical factors that affect output. Although many studies and reviews have addressed how tissue properties and fluid mechanics (i.e. pressure gradients) affect lymph transport [1-3] there is less known about lymphatic mechanobiology. As opposed to passive mechanical properties, mechanobiology describes the active coupling of mechanical signals and biochemical pathways. Lymphatic vasomotion is the result of a fascinating system affected by mechanical forces exerted by the flowing lymph, including pressure-induced vessel stretch and flow-induced shear stresses. These forces can trigger or modulate biochemical pathways important for controlling the lymphatic contractions. Here, I review the current understanding of lymphatic vessel function, focusing on vessel mechanobiology, and summarize the prospects for a comprehensive understanding that integrates the mechanical and biomechanical control mechanisms in the lymphatic system.
Collapse
Affiliation(s)
- Lance L Munn
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, United States.
| |
Collapse
|
20
|
Chakraborty S, Davis MJ, Muthuchamy M. Emerging trends in the pathophysiology of lymphatic contractile function. Semin Cell Dev Biol 2015; 38:55-66. [PMID: 25617600 DOI: 10.1016/j.semcdb.2015.01.005] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2014] [Revised: 01/12/2015] [Accepted: 01/13/2015] [Indexed: 01/19/2023]
Abstract
Lymphatic contractile dysfunction is central to a number of pathologies that affect millions of people worldwide. Due to its critical role in the process of inflammation, a dysfunctional lymphatic system also compromises the immune response, further exacerbating a number of inflammation related diseases. Despite the critical physiological functions accomplished by the transport of lymph, a complete understanding of the contractile machinery of the lymphatic system lags far behind that of the blood vasculature. However, there has been a surge of recent research focusing on different mechanisms that underlie both physiological and pathophysiological aspects of lymphatic contractile function. This review summarizes those emerging paradigms that shed some novel insights into the contractile physiology of the lymphatics in normal as well as different disease states. In addition, this review emphasizes the recent progress made in our understanding of various contractile parameters and regulatory elements that contribute to the normal functioning of the lymphatics.
Collapse
Affiliation(s)
- Sanjukta Chakraborty
- Department of Medical Physiology, Cardiovascular Research Institute Division of Lymphatic Biology, Texas A&M Health Science Center College of Medicine, United States
| | - Michael J Davis
- Department of Medical Pharmacology and Physiology, University of Missouri School of Medicine, United States.
| | - Mariappan Muthuchamy
- Department of Medical Physiology, Cardiovascular Research Institute Division of Lymphatic Biology, Texas A&M Health Science Center College of Medicine, United States.
| |
Collapse
|
21
|
Oshiro H, Miura M, Iobe H, Kudo T, Shimazu Y, Aoba T, Okudela K, Nagahama K, Sakamaki K, Yoshida M, Nagao T, Nakaya T, Kurata A, Ohtani O. Lymphatic Stomata in the Adult Human Pulmonary Ligament. Lymphat Res Biol 2014; 13:137-45. [PMID: 25526320 DOI: 10.1089/lrb.2014.0009] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Lymphatic stomata are small lymphatic openings in the serosal membrane that communicate with the serosal cavity. Although these stomata have primarily been studied in experimental mammals, little is known concerning the presence and properties of lymphatic stomata in the adult human pleura. Thus, adult human pleurae were examined for the presence or absence of lymphatic stomata. METHODS AND RESULTS A total of 26 pulmonary ligaments (13 left and 13 right) were obtained from 15 adult human autopsy cases and examined using electron and light microscopy. The microscopic studies revealed the presence of apertures fringed with D2-40-positive, CD31-positive, and cytokeratin-negative endothelial cells directly communicating with submesothelial lymphatics in all of the pulmonary ligaments. The apertures' sizes and densities varied from case to case according to the serial tissue section. The medians of these aperture sizes ranged from 2.25 to 8.75 μm in the left pulmonary ligaments and from 2.50 to 12.50 μm in the right pulmonary ligaments. The densities of the apertures ranged from 2 to 9 per mm(2) in the left pulmonary ligaments and from 2 to 18 per mm(2) in the right pulmonary ligaments. However, no significant differences were found regarding the aperture size (p=0.359) and density (p=0.438) between the left and the right pulmonary ligaments. CONCLUSIONS Our study revealed that apertures exhibit structural adequacy as lymphatic stomata on the surface of the pulmonary ligament, thereby providing evidence that lymphatic stomata are present in the adult human pleura.
Collapse
Affiliation(s)
- Hisashi Oshiro
- 1 Department of Anatomic Pathology, Tokyo Medical University , Tokyo, Japan .,5 Department of Pathology, Yokohama City University Graduate School of Medicine , Yokohama, Japan
| | - Masahiro Miura
- 2 Department of Human Anatomy, Oita University , Oita, Japan
| | - Hiroaki Iobe
- 1 Department of Anatomic Pathology, Tokyo Medical University , Tokyo, Japan
| | - Tomoo Kudo
- 4 Department of Pathology, Nippon Dental University , Tokyo, Japan
| | | | - Takaaki Aoba
- 4 Department of Pathology, Nippon Dental University , Tokyo, Japan
| | - Koji Okudela
- 5 Department of Pathology, Yokohama City University Graduate School of Medicine , Yokohama, Japan
| | - Kiyotaka Nagahama
- 5 Department of Pathology, Yokohama City University Graduate School of Medicine , Yokohama, Japan
| | - Kentaro Sakamaki
- 6 Department of Biostatistics and Epidemiology, Yokohama City University Graduate School of Medicine , Yokohama, Japan
| | - Maki Yoshida
- 1 Department of Anatomic Pathology, Tokyo Medical University , Tokyo, Japan
| | - Toshitaka Nagao
- 1 Department of Anatomic Pathology, Tokyo Medical University , Tokyo, Japan
| | - Takeo Nakaya
- 3 Department of Molecular Pathology, Tokyo Medical University , Tokyo, Japan
| | - Atsushi Kurata
- 3 Department of Molecular Pathology, Tokyo Medical University , Tokyo, Japan
| | - Osamu Ohtani
- 7 Department of Anatomy, University of Toyama Graduate School of Medicine and Pharmaceutical Sciences , Toyama, Japan
| |
Collapse
|
22
|
Dongaonkar RM, Nguyen TL, Quick CM, Heaps CL, Hardy J, Laine GA, Wilson E, Stewart RH. Mesenteric lymphatic vessels adapt to mesenteric venous hypertension by becoming weaker pumps. Am J Physiol Regul Integr Comp Physiol 2014; 308:R391-9. [PMID: 25519727 DOI: 10.1152/ajpregu.00196.2014] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Lymphangions, the segments of lymphatic vessels between two adjacent lymphatic valves, actively pump lymph. Acute changes in transmural pressure and lymph flow have profound effects on lymphatic pump function in vitro. Chronic changes in pressure and flow in vivo have also been reported to lead to significant changes in lymphangion function. Because changes in pressure and flow are both cause and effect of adaptive processes, characterizing adaptation requires a more fundamental analysis of lymphatic muscle properties. Therefore, the purpose of the present work was to use an intact lymphangion isovolumetric preparation to evaluate changes in mesenteric lymphatic muscle mechanical properties and the intracellular Ca(2+) in response to sustained mesenteric venous hypertension. Bovine mesenteric veins were surgically occluded to create mesenteric venous hypertension. Postnodal mesenteric lymphatic vessels from mesenteric venous hypertension (MVH; n = 6) and sham surgery (Sham; n = 6) animals were isolated and evaluated 3 days after the surgery. Spontaneously contracting MVH vessels generated end-systolic active tension and end-diastolic active tension lower than the Sham vessels. Furthermore, steady-state active tension and intracellular Ca(2+) concentration levels in response to KCl stimulation were also significantly lower in MVH vessels compared with those of the Sham vessels. There was no significant difference in passive tension in lymphatic vessels from the two groups. Taken together, these results suggest that following 3 days of mesenteric venous hypertension, postnodal mesenteric lymphatic vessels adapt to become weaker pumps with decreased cytosolic Ca(2+) concentration.
Collapse
Affiliation(s)
- R M Dongaonkar
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| | - T L Nguyen
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| | - C M Quick
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas;
| | - C L Heaps
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| | - J Hardy
- Large Animal Clinical Sciences, Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, Texas; and
| | - G A Laine
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| | - E Wilson
- Department of Medical Physiology, Texas A&M Health Science Center, Texas A&M University, College Station, Texas
| | - R H Stewart
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| |
Collapse
|
23
|
von der Weid PY, Lee S, Imtiaz MS, Zawieja DC, Davis MJ. Electrophysiological properties of rat mesenteric lymphatic vessels and their regulation by stretch. Lymphat Res Biol 2014; 12:66-75. [PMID: 24865781 DOI: 10.1089/lrb.2013.0045] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND In mammals, lymph is propelled centrally primarily via the phasic contractions of collecting lymphatic vessels, known as lymphatic pumping. Electrophysiological studies conducted in guinea pig and sheep mesenteric lymphatic vessels indicate that contractions are initiated in the lymphatic muscle by nifedipine-sensitive action potentials (APs). Lymphatic pumping is highly sensitive to luminal fluid loading and the mechanical properties of this stretch-induced pumping have been consistently studied, in particular in rat mesenteric lymphatic vessels. However, membrane potential (Vm) and the electrophysiological events underlying stretch-induced lymphatic pumping have not been investigated in the rat. The aim of this study was thus to examine the properties of rat mesenteric lymphatic muscle Vm under resting conditions and to assess changes in Vm caused by distension. METHODS AND RESULTS Lymphatic muscle Vm was measured with sharp intracellular microelectrodes either in unstretched conditions or under isometric tension provided by a wire-myograph. In unstretched vessels, Vm was -48 ± 2 mV (n=30). APs (amplitude ∼25 mV) were observed at a frequency of ∼8/min and were abolished by nifedipine. Under isometric tension, Vm was less polarized (-36 ± 1 mV, n=23), even at minimum tension. Increase in tension led to increase in contraction strength and contraction/AP frequency, while Vm was slightly hyperpolarized and AP amplitude not markedly altered. CONCLUSIONS In our experimental conditions, rat lymphatic muscle has electrophysiological characteristics similar to that in other species. It responds to an increase in isometric tension with an increase in AP frequency, but resting Vm is not significantly affected.
Collapse
Affiliation(s)
- Pierre-Yves von der Weid
- 1 Inflammation Research Network and Smooth Muscle Research Group, Snyder Institute for Chronic Diseases, Department of Physiology and Pharmacology, Faculty of Medicine, University of Calgary , Calgary, Alberta, Canada
| | | | | | | | | |
Collapse
|
24
|
Ganusov VV, Auerbach J. Mathematical modeling reveals kinetics of lymphocyte recirculation in the whole organism. PLoS Comput Biol 2014; 10:e1003586. [PMID: 24830705 PMCID: PMC4022467 DOI: 10.1371/journal.pcbi.1003586] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2013] [Accepted: 03/12/2014] [Indexed: 12/20/2022] Open
Abstract
The kinetics of recirculation of naive lymphocytes in the body has important implications for the speed at which local infections are detected and controlled by immune responses. With a help of a novel mathematical model, we analyze experimental data on migration of 51Cr-labeled thoracic duct lymphocytes (TDLs) via major lymphoid and nonlymphoid tissues of rats in the absence of systemic antigenic stimulation. We show that at any point of time, 95% of lymphocytes in the blood travel via capillaries in the lung or sinusoids of the liver and only 5% migrate to secondary lymphoid tissues such as lymph nodes, Peyer's patches, or the spleen. Interestingly, our analysis suggests that lymphocytes travel via lung capillaries and liver sinusoids at an extremely rapid rate with the average residence time in these tissues being less than 1 minute. The model also predicts a relatively short average residence time of TDLs in the spleen (2.5 hours) and a longer average residence time of TDLs in major lymph nodes and Peyer's patches (10 hours). Surprisingly, we find that the average residence time of lymphocytes is similar in lymph nodes draining the skin (subcutaneous LNs) or the gut (mesenteric LNs) or in Peyer's patches. Applying our model to an additional dataset on lymphocyte migration via resting and antigen-stimulated lymph nodes we find that enlargement of antigen-stimulated lymph nodes occurs mainly due to increased entrance rate of TDLs into the nodes and not due to decreased exit rate as has been suggested in some studies. Taken together, our analysis for the first time provides a comprehensive, systems view of recirculation kinetics of thoracic duct lymphocytes in the whole organism.
Collapse
Affiliation(s)
- Vitaly V. Ganusov
- Department of Microbiology, University of Tennessee, Knoxville, Tennessee, United States of America
- Department of Mathematics, University of Tennessee, Knoxville, Tennessee, United States of America
| | - Jeremy Auerbach
- Department of Mathematics, University of Tennessee, Knoxville, Tennessee, United States of America
| |
Collapse
|
25
|
Quick CM, Criscione JC, Kotiya A, Dongaonkar RM, Hardy J, Wilson E, Gashev AA, Laine GA, Stewart RH. Functional adaptation of bovine mesenteric lymphatic vessels to mesenteric venous hypertension. Am J Physiol Regul Integr Comp Physiol 2014; 306:R901-7. [PMID: 24671245 DOI: 10.1152/ajpregu.00185.2013] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Lymph flow is the primary mechanism for returning interstitial fluid to the blood circulation. Currently, the adaptive response of lymphatic vessels to mesenteric venous hypertension is not known. This study sought to determine the functional responses of postnodal mesenteric lymphatic vessels. We surgically occluded bovine mesenteric veins to create mesenteric venous hypertension to elevate mesenteric lymph flow. Three days after surgery, postnodal mesenteric lymphatic vessels from mesenteric venous hypertension (MVH; n = 7) and sham surgery (Sham; n = 6) group animals were evaluated and compared. Contraction frequency (MVH: 2.98 ± 0.75 min(-1); Sham: 5.42 ± 0.81 min(-1)) and fractional pump flow (MVH: 1.14 ± 0.30 min(-1); Sham: 2.39 ± 0.32 min(-1)) were significantly lower in the venous occlusion group. These results indicate that postnodal mesenteric lymphatic vessels adapt to mesenteric venous hypertension by reducing intrinsic contractile activity.
Collapse
Affiliation(s)
- Christopher M Quick
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas; Department of Biomedical Engineering, Texas A&M University, College Station, Texas;
| | - John C Criscione
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas; Department of Biomedical Engineering, Texas A&M University, College Station, Texas
| | - Akhilesh Kotiya
- Department Biomedical Engineering, Dalhousie University, Halifax, Nova Scotia, Canada
| | | | - Joanne Hardy
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas; Large Animal Clinical Sciences, Texas A&M University, College Station, Texas; and
| | - Emily Wilson
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas; Systems Biology and Translational Medicine, Texas A&M Health Science Center, Temple, Texas
| | - Anatoliy A Gashev
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas; Systems Biology and Translational Medicine, Texas A&M Health Science Center, Temple, Texas
| | - Glen A Laine
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| | - Randolph H Stewart
- Michael E. DeBakey Institute, Texas A&M University, College Station, Texas
| |
Collapse
|
26
|
Gasheva OY, Gashev AA, Zawieja DC. Cyclic guanosine monophosphate and the dependent protein kinase regulate lymphatic contractility in rat thoracic duct. J Physiol 2013; 591:4549-65. [PMID: 23836689 DOI: 10.1113/jphysiol.2013.258681] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
We have previously demonstrated a principal role for nitric oxide (NO) in the endothelium/shear-dependent regulation of contractility in rat thoracic duct (TD). In this study we tested the hypothesis that cyclic guanosine monophosphate (cGMP) and the dependent protein kinase (PKG) are central to the intrinsic and extrinsic flow-dependent modulation of lymphatic contractility. Lymphatic diameters and indices of pumping in isolated, cannulated and pressurized segments of rat TD were measured. The influences of increased transmural pressure (1-5 cmH2O) and imposed flow (1-5 cm H2O transaxial pressure gradients) on lymphatic function were studied before and after: (1) inhibition of guanylate cyclase (GC) with and without a NO donor; (2) application of stable cGMP analogue; and (3) inhibition of the cGMP activation of PKG. Additionally, Western blotting and immunofluorescent tissue staining were used to analyse the PKG isoforms expressed in TD. We found that the GC inhibitor ODQ induced changes in TD contractility similar to NO synthase blockade and prevented the relaxation induced by the NO donor S-nitroso-N-acetylpenicillamine. The cGMP analogue, 8-(4-Chlorophenylthio)-guanosine 3,5-cyclic monophosphate sodium salt (8pCPTcGMP), mimicked the extrinsic flow-induced relaxation in a dose-dependent manner, whereas treatment with the cGMP/PKG inhibitor, guanosine 3,5-cyclic monophosphorothioate, 8-(4-chlorophenylthio)-, Rp-isomer, triethylammonium salt (Rp-8-Br-PETcGMPS), eliminated intrinsic flow-dependent relaxation, and largely inhibited extrinsic flow-dependent relaxation. Western blotting demonstrated that both PKG-Iα and -Iβ isoforms are found in TD, with ∼10 times greater expression of the PKG-Iα protein in TD compared with the aorta and vena cava. The PKG-Iβ isoform expressed equally in TD and vena cava, both being ∼2 times higher than that in the aorta. Immunofluorescent labelling of PKG-Iα protein in the wall of rat thoracic duct confirmed its localization inside TD muscle cells. These findings demonstrate that cGMP is critical to the flow-dependent regulation of TD contractility; they also indicate an important involvement of PKG, especially PKG-Iα in these processes and identifies PKG protein as a potential therapeutic target.
Collapse
Affiliation(s)
- Olga Yu Gasheva
- O. Y. Gasheva: Department of Medical Physiology, College of Medicine, Cardiovascular Research Institute Division of Lymphatic Biology, Texas A&M Health Science Center, 702 SW H.K. Dodgen Loop, Temple, TX 76504, USA.
| | | | | |
Collapse
|