1
|
Hill T, Conolly RB. Development of a Novel AOP for Cyp2F2-Mediated Lung Cancer in Mice. Toxicol Sci 2019; 172:1-10. [PMID: 31407013 DOI: 10.1093/toxsci/kfz185] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2019] [Revised: 06/26/2019] [Accepted: 08/07/2019] [Indexed: 12/14/2022] Open
Abstract
Abstract
Traditional methods for carcinogenicity testing rely heavily on the rodent bioassay as the standard for identification of tumorigenic risk. As such, identification of species-specific outcomes and/or metabolism are a frequent argument for regulatory exemption. One example is the association of tumor formation in the mouse lung after exposure to Cyp2F2 ligands. The adverse outcome pathway (AOP) framework offers a theoretical platform to address issues of species specificity that is consistent, transparent, and capable of integrating data from new approach methodologies as well as traditional data streams. A central premise of the AOP concept is that pathway progression from the molecular initiating event (MIE) implies a definable “response-response” (R-R) relationship between each key event (KE) that drives the pathway towards a specific adverse outcome (AO). This article describes an AOP for lung cancer in the mouse from an MIE of Cyp2F2-specific reactive metabolite formation, advancing through KE that include protein and/or nucleic acid adducts, diminished Club Cell 10 kDa (CC10) protein expression, hyperplasia of CC10 deficient Club cells, and culminating in the AO of mixed-cell tumor formation in the distal airways. This tumor formation is independent of route of exposure and our AOP construct is based on overlapping mechanistic events for naphthalene, styrene, ethyl benzene, isoniazid, and fluensulfone in the mouse. This AOP is intended to accelerate the explication of an apparent mouse-specific outcome and serve as a starting point for a quantitative analysis of mouse-human differences in susceptibility to the tumorigenic effects of Cyp2F2 ligands.
Collapse
Affiliation(s)
- Thomas Hill
- Oak Ridge Institute for Science and Education Fellow at the National Health and Environmental Effects Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27709
| | - Rory B Conolly
- National Health and Environmental Effects Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina 27709
| |
Collapse
|
2
|
Shen S, Li L, Ding X, Zheng J. Metabolism of styrene to styrene oxide and vinylphenols in cytochrome P450 2F2- and P450 2E1-knockout mouse liver and lung microsomes. Chem Res Toxicol 2014; 27:27-33. [PMID: 24320693 PMCID: PMC4041473 DOI: 10.1021/tx400305w] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Pulmonary toxicity of styrene is initiated by cytochromes P450-dependent metabolic activation. P450 2E1 and P450 2F2 are considered to be two main cytochrome P450 enzymes responsible for styrene metabolism in mice. The objective of the current study was to determine the correlation between the formation of styrene metabolites (i.e., styrene oxide and 4-vinylphenol) and pulmonary toxicity of styrene, using Cyp2e1- and Cyp2f2-null mouse models. A dramatic decrease in the formation of styrene glycol and 4-vinylphenol was found in Cyp2f2-null mouse lung microsomes relative to that in the wild-type mouse lung microsomes; however, no significant difference in the production of the styrene metabolites was observed between lung microsomes obtained from Cyp2e1-null and the wild-type mice. The knockout and wild-type mice were treated with styrene (6.0 mmol/kg, ip), and cell counts and LDH activity in bronchoalveolar lavage fluids were monitored to evaluate the pulmonary toxicity induced by styrene. Cyp2e1-null mice displayed a susceptibility to lung toxicity of styrene similar to that of the wild-type animals; however, Cyp2f2-null mice were resistant to styrene-induced pulmonary toxicity. In conclusion, both P450 2E1 and P450 2F2 are responsible for the metabolic activation of styrene. The latter enzyme plays an important role in styrene-induced pulmonary toxicity. Both styrene oxide and 4-vinylphenol are suggested to participate in the development of lung injury induced by styrene.
Collapse
Affiliation(s)
- Shuijie Shen
- Center for Developmental Therapeutics, Seattle Children's Research Institute, Seattle, Washington 98101
| | - Lei Li
- Wadsworth Center, New York State Department of Health, and School of Public Health, State University of New York at Albany, Albany, New York 12201
| | - Xinxin Ding
- Wadsworth Center, New York State Department of Health, and School of Public Health, State University of New York at Albany, Albany, New York 12201
| | - Jiang Zheng
- Center for Developmental Therapeutics, Seattle Children's Research Institute, Seattle, Washington 98101
- Division of Gastroenterology and Hepatology, Department of Pediatrics, University of Washington, Seattle, Washington 98105
- Shenyang Pharmaceutical University, Shenyang, 110016, P. R. China
| |
Collapse
|
3
|
Krishnan S, Bajrami B, Mani V, Pan S, Rusling JF. Comparison of DNA-Reactive Metabolites from Nitrosamine and Styrene Using Voltammetric DNA/Microsomes Sensors. ELECTROANAL 2009; 21:1005-1013. [PMID: 23100998 DOI: 10.1002/elan.200804521] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Voltammetric sensors made with films of polyions, double-stranded DNA and liver microsomes adsorbed layer-by-layer onto pyrolytic graphite electrodes were evaluated for reactive metabolite screening. This approach features simple, inexpensive screening without enzyme purification for applications in drug or environmental chemical development. Cytochrome P450 enzymes (CYPs) in the liver microsomes were activated by an NADPH regenerating system or by electrolysis to metabolize model carcinogenic compounds nitrosamine and styrene. Reactive metabolites formed in the films were trapped as adducts with nucleobases on DNA. The DNA damage was detected by square-wave voltammetry (SWV) using [Formula: see text] as a DNA-oxidation catalyst. These sensors showed a larger rate of increase in signal vs. reaction time for a highly toxic nitrosamine than for the moderately toxic styrene due to more rapid reactive metabolite-DNA adduct formation. Results were consistent with reported in vivo TD(50) data for the formation of liver tumors in rats. Analogous polyion/ liver microsome films prepared on 500 nm silica nanoparticles (nanoreactors) and reacted with nitrosamine or styrene, provided LC-MS or GC analyses of metabolite formation rates that correlated well with sensor response.
Collapse
Affiliation(s)
- Sadagopan Krishnan
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, USA
| | | | | | | | | |
Collapse
|
4
|
Krishnan S, Hvastkovs EG, Bajrami B, Choudhary D, Schenkman JB, Rusling JF. Synergistic metabolic toxicity screening using microsome/DNA electrochemiluminescent arrays and nanoreactors. Anal Chem 2008; 80:5279-85. [PMID: 18563913 PMCID: PMC3483639 DOI: 10.1021/ac800763r] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Platforms based on thin enzyme/DNA films were used in two-tier screening of chemicals for reactive metabolites capable of producing toxicity. Microsomes were used for the first time as sources of cytochrome (cyt) P450 enzymes in these devices. Initial rapid screening involved electrochemiluminescent (ECL) arrays featuring spots containing ruthenium poly(vinylpyridine), DNA, and rat liver microsomes or bicistronically expressed human cyt P450 2E1 (h2E1). Cyt P450 enzymes were activated via the NADPH/reductase cycle. When bioactivation of substrates in the films gives reactive metabolites, they are trapped by covalent attachment to DNA bases. The rate of increase in ECL with enzyme reaction time reflects relative DNA damage rates. "Toxic hits" uncovered by the array were studied in structural detail by using enzyme/DNA films on silica nanospheres as "nanoreactors" to provide nucleobase adducts from reactive metabolites. The utility of this synergistic approach was demonstrated by estimating relative DNA damage rates of three mutagenic N-nitroso compounds and styrene. Relative enzyme turnover rates for these compounds using ECL arrays and LC-UV-MS correlated well with TD 50 values for liver tumor formation in rats. Combining ECL array and nanoreactor/LC-MS technologies has the potential for rapid, high-throughput, cost-effective screening for reactive metabolites and provides chemical structure information that is complementary to conventional toxicity bioassays.
Collapse
|
5
|
Luderer U, Collins TFX, Daston GP, Fischer LJ, Gray RH, Mirer FE, Olshan AF, Setzer RW, Treinen KA, Vermeulen R. NTP-CERHR Expert Panel Report on the reproductive and developmental toxicity of styrene. ACTA ACUST UNITED AC 2006; 77:110-93. [PMID: 16345075 DOI: 10.1002/bdrb.20061] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
6
|
Abstract
Neutral hydrolysis and LC-MS/MS analysis of 6-nm-thick DNA-polyion films used in voltammetric genotoxicity screening sensors showed that concentrations of N7-guanine DNA adducts with methyl methanesulfonate and styrene oxide increased with incubation time with the same trends as found for sensor response. Results show that the genotoxicity sensors can be used to estimate relative DNA damage rates for chemical toxicity screening. Neutral thermal hydrolysis provided a relatively clean sample matrix allowing quantitative estimates of nucleobase adducts after several minutes of incubation with damage agents. In addition, an approximate standardization procedure for neutral thermal hydrolysis was developed and validated that avoids need for a pure standard and should be useful in cases where nucleobase adduct standards are unavailable or where their identities are unknown.
Collapse
Affiliation(s)
- Maricar Tarun
- Department of Chemistry, 55 North Eagleville Road, University of Connecticut, Storrs, Connecticut 06269-3060, USA
| | | |
Collapse
|
7
|
Abstract
Responses from "reagentless" DNA-based electrochemical toxicity sensors to DNA alkylating agents styrene oxide (SO), diepoxybutane (DEB), and methyl methanesulfonate (MMS) were compared to formation rates of total alkylated nucleobases in DNA measured by LC-UV-MS. Sensors utilized a catalytic metallopolymer in DNA films previously exposed to the damage agents. To achieve adequate sensitivity, LC-UV-MS analyses were done on DNA in solution reacted with the damage agents, and subsequently hydrolyzed to nucleosides with enzymes. Sensor response correlated well with nucleobase-adduct formation rates obtained by the molecule-specific analyses. Results confirm that the metallopolymer-DNA film sensors can be used to estimate relative DNA damage rates from nucleobase adduct-forming chemicals. Results from both methods correlated well with animal genotoxicity as estimated by TDL(o) values, the lowest dose producing carcinogenicity, in mice and rats. These sensors should be useful for rapid, inexpensive screening of moderately and severely genotoxic new chemicals.
Collapse
Affiliation(s)
- Jing Yang
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, USA
| | | | | |
Collapse
|
8
|
Zilli M, Converti A, Di Felice R. Macrokinetic and quantitative microbial investigation on a bench-scale biofilter treating styrene-polluted gaseous streams. Biotechnol Bioeng 2003; 83:29-38. [PMID: 12740930 DOI: 10.1002/bit.10640] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
We performed a macrokinetic and quantitative microbial investigation of a continuously operating bench-scale biofilter treating styrene-polluted gases. The device was filled with a mixture of peat and glass beads as packing medium and inoculated with the styrene-oxidizing strain, Rhodococcus rhodochrous AL NCIMB 13259. The experimental data of styrene and microbial concentrations, obtained at different biofilter heights, were used to evaluate the pollutant concentration profiles as well as the influence of styrene loading on biomass distribution along the packing medium. Styrene and biomass concentration profiles permitted detection of a linear relationship between the amount of biomass grown in a given section of the biofilter and that of pollutant removed, regardless of the operating conditions tested. Biomass development in the bed appeared to: depend linearly on pollutant concentration at an inlet styrene concentration of <0.10 g m(-3) in the gaseous stream; achieve a maximum value (7. 10(7) colony forming units per gram of packing material) within a wide styrene concentration range (0.10 to 1.0 g m(-3)); and fall sharply beyond this inhibition threshold. The process followed zeroth-order macrokinetics with respect to styrene concentration, which is consistent with zeroth-order microkinetics with either fully active or not fully active biofilm. The maximal volumetric styrene removal rate was found to be 63 g m(packing material) (-3) h(-1) for an influent pollutant concentration of 0.80 g m(-3) and a superficial gas velocity of 245 m h(-1).
Collapse
Affiliation(s)
- Mario Zilli
- Department of Chemical and Process Engineering G.B. Bonino, Genoa University, Via Opera Pia 15, I-16145, Genoa, Italy.
| | | | | |
Collapse
|
9
|
Wang B, Rusling JF. Voltammetric Sensor for Chemical Toxicity Using [Ru(bpy)2poly(4-vinylpyridine)10Cl)]+ as Catalyst in Ultrathin Films. DNA Damage from Methylating Agents and an Enzyme-Generated Epoxide. Anal Chem 2003; 75:4229-35. [PMID: 14632140 DOI: 10.1021/ac034097u] [Citation(s) in RCA: 75] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Films containing presynthesized [Ru(bpy)2poly(4-vinylpyridine)10Cl)]Cl and ds-DNA grown layer by layer by alternate electrostatic assembly were used to detect DNA damage from an epoxide metabolite and methylating agents on a reaction time scale of minutes. The redox polymer [Ru(bpy)2poly(4-vinylpyridine)10Cl)]Cl was used as an inner layer in films 14-25 nm thick to catalyze the voltammetric oxidation of guanine bases of ds-DNA in the outer layers. This film architecture provides a self-contained, reagentless sensor for toxicity screening based on detection of DNA damage. Films were incubated with reactants and washed, and then DNA damage was analyzed by square wave voltammetry (SWV). Bioactivation of styrene to its metabolite styrene oxide was accomplished by incorporating the protein myoglobin into the films to catalyze the conversion. DNA damage caused the catalytic SWV peaks at approximately 0.75 V vs SCE to increase nearly linearly over the first 10-20 min of reaction, depending on the damage agent employed. Such prototype toxicity biosensors hold promise for in vitro screening of new agricultural chemicals and drugs for potential genotoxicity.
Collapse
Affiliation(s)
- Bingquan Wang
- Department of Chemistry, University of Connecticut, U-60, 55 North Eagleview Road, Storrs, Connecticut 06269-3060, USA
| | | |
Collapse
|
10
|
Abstract
Direct electrochemiluminescence (ECL) involving DNA was demonstrated in 10 nm films of cationic polymer [Ru(bpy)(2)(PVP)(10)](2+) assembled layer-by-layer with DNA. A square wave voltammetric waveform oxidized the Ru(II) sites in the metallopolymer to Ru(III), and ECL was measured simultaneously with catalytic voltammetric peaks in a simple apparatus. Significant ECL generation occurred only when guanine bases were present on oligonucleotides in the films. This result along with knowledge of proposed ECL pathways suggests that guanine radicals initially formed by catalytic oxidation of guanines by Ru(III) react with the metallopolymer to produce electronically exited Ru(II) sites in the film. ECL and catalytic SWV peaks were sensitive to oligonucleotide hybridization and chemical DNA damage. Simultaneous linear growth of ECL and SWV peaks occurred after incubation with known DNA damage agent styrene oxide over 20 min. The estimated detection limit was 1 damaged DNA base in 1000. Control incubations of metallopolymer/ds-DNA films in buffer containing unreactive toluene resulted in no significant changes of the ECL or SWV peaks.
Collapse
Affiliation(s)
- Lynn Dennany
- National Centre for Sensor Research, School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| | | | | |
Collapse
|
11
|
Zhou L, Yang J, Estavillo C, Stuart JD, Schenkman JB, Rusling JF. Toxicity screening by electrochemical detection of DNA damage by metabolites generated in situ in ultrathin DNA-enzyme films. J Am Chem Soc 2003; 125:1431-6. [PMID: 12553846 DOI: 10.1021/ja0290274] [Citation(s) in RCA: 111] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Rapid detection of DNA damage could serve as a basis for in vitro genotoxicity screening for new organic compounds. Ultrathin films (20-40 nm) containing myoglobin or cytochrome P450(cam) and DNA grown layer-by-layer on electrodes were activated by hydrogen peroxide, and the enzyme in the film generated metabolite styrene oxide from styrene. This styrene oxide reacted with double stranded (ds)-DNA in the same film, mimicking metabolism and DNA damage in human liver. DNA damage was detected by square wave voltammetry (SWV) by using catalytic oxidation with Ru(bpy)(3)(2+) (bpy = 2,2'-bipyridine) and by monitoring the binding of Co(bpy)(3)(3+). Damaged DNA reacts more rapidly than intact ds-DNA with Ru(bpy)(3)(3+), giving SWV peaks at approximately 1 V versus SCE that grow larger with reaction time. Co(bpy)(3)(3+) binds more strongly to intact ds-DNA, and its SWV peaks at 0.04 V decreased as DNA was damaged. Little change in SWV signals was found for incubations of DNA/enzyme films with unreactive organic controls or hydrogen peroxide. Capillary electrophoresis and HPLC-MS suggested the formation of styrene oxide adducts of DNA bases under similar reaction conditions in thin films and in solution. The catalytic SWV method was more sensitive than the Co(bpy)(3)(3+) binding assay, providing multiple measurements over a 5 min reaction time.
Collapse
Affiliation(s)
- Liping Zhou
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269-3060, USA
| | | | | | | | | | | |
Collapse
|
12
|
Otteneder M, Lutz U, Lutz WK. DNA adducts of styrene-7,8-oxide in target and non-target organs for tumor induction in rat and mouse after repeated inhalation exposure to styrene. Mutat Res 2002; 500:111-6. [PMID: 11890940 DOI: 10.1016/s0027-5107(02)00008-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Styrene by inhalation had been shown to increase the lung tumor incidence in mice at 20 ppm and higher, but was not carcinogenic in rats at up to 1000 ppm. Styrene-7,8-oxide, the major metabolic intermediate, has weak electrophilic reactivity. Therefore, DNA adduct formation was expected at a low level and a 32P-postlabeling method for a determination of the two regioisomeric 2'-deoxyguanosyl-O6-adducts at the alpha(7)- and beta(8)-positions had been established. The first question was whether DNA adducts could be measured in the rat at the end of the 2 years exposure of a bioassay for carcinogenicity, even though tumor incidence was not increased. Liver samples of male and female CD rats were available for DNA adduct analysis. Adducts were above the limit of detection only in the highest dose group (1000 ppm), with median levels of 9 and 8 adducts per 10(7) nucleotides in males and females, respectively (sum of alpha- and beta-adducts). The result indicates that the rat liver tolerated a relatively high steady-state level of styrene-induced DNA adducts without detectable increase in tumor formation. The second question was whether different DNA adduct levels in the lung of rats and mice could account for the species difference in tumor incidence. Groups of female CD-1 mice were exposed for 2 weeks to 0, 40, and 160 ppm styrene (6h per day; 5 days per week), female CD rats were exposed to 0 and 500 ppm. In none of the lung DNA samples were adducts above a limit of detection of 1 adduct per 10(7) DNA nucleotides. The data indicate that species- and organ-specific tumor induction by styrene is not reflected by DNA adduct levels determined in tissue homogenate. The particular susceptibility of the mouse lung might have to be based on other reactive metabolites and DNA adducts, indirect DNA damage and/or cell-type specific toxicity and tumor promotion.
Collapse
Affiliation(s)
- M Otteneder
- Department of Toxicology, University of Würzburg, Versbacher Strasse 9, D-97078 Würzburg, Germany
| | | | | |
Collapse
|
13
|
Abstract
A sensor constructed by alternate layer-by-layer adsorption of PDDA cations and double-stranded (ds)-DNA on oxidized pyrolytic graphite electrodes was evaluated for detection of chemical damage to ds-DNA from known damage agent styrene oxide. Films made with PDDA ions of structure (PDDA/DNA)2 were approximately 6 nm thick and contained 0.23 microg of ds-DNA. Catalytic oxidation using 50 microM Ru(bpy)3(2+) (bpy = 2,2'-bipyridine) and square wave voltammetry (SWV) provided more sensitive detection of DNA damage than direct SWV oxidation. The catalytic peaks increased linearly with time during incubations with styrene oxide, but only minor changes were detected during incubation with nonreactive toluene. For best sensitivity, the outer layer of the film must be ds-DNA, and analysis should be done at low salt concentration. Studies of DNA and polynucleotides in solutions and films suggested that oxidation of guanine and chemically damaged adenine in partly unraveled, damaged DNA were the most likely contributors to the catalytic peak.
Collapse
Affiliation(s)
- L Zhou
- Department of Chemistry, University of Connecticut, Storrs 06269-3060, USA
| | | |
Collapse
|
14
|
Hennard C, Finneman J, Harris CM, Harris TM, Stone MP. The nonmutagenic (R)- and (S)-beta-(N(6)-adenyl)styrene oxide adducts are oriented in the major groove and show little perturbation to DNA structure. Biochemistry 2001; 40:9780-91. [PMID: 11502171 DOI: 10.1021/bi010564v] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Conformations of (R)-beta-(N(6)-adenyl)styrene oxide and (S)-beta-(N(6)-adenyl)styrene oxide adducts at position X(6) in d(CGGACXAGAAG).d(CTTCTTGTCCG), incorporating codons 60, 61 (underlined), and 62 of the human N-ras protooncogene, were refined from (1)H NMR data. These were designated as the beta-R(61,2) and beta-S(61,2) adducts. A total of 533 distance restraints and 162 dihedral restraints were used for the molecular dynamics calculations of the beta-S(61,2) adduct, while 518 distances and 163 dihedrals were used for the beta-R(61,2) adduct. The increased tether length of the beta-adducts results in two significant changes in adduct structure as compared to the corresponding alpha-styrenyl adducts [Stone, M. P., and Feng, B. (1996) Magn. Reson. Chem. 34, S105-S114]. First, it reduces the distortion introduced into the DNA duplex. For both the beta-R(61,2) and beta-S(61,2) adducts, the styrenyl moiety was positioned in the major groove of the duplex with little steric hindrance. Second, it mutes the influence of stereochemistry at the alpha-carbon such that both the beta-R(61,2) and beta-S(61,2) adducts exhibit similar conformations. The results were correlated with site-specific mutagenesis experiments that revealed the beta-R(61,2) and beta-S(61,2) adducts were not mutagenic and did not block polymerase bypass.
Collapse
Affiliation(s)
- C Hennard
- Department of Chemistry and Center in Molecular Toxicology, Vanderbilt University, Nashville, Tennessee 37235, USA
| | | | | | | | | |
Collapse
|
15
|
Cruzan G, Cushman JR, Andrews LS, Granville GC, Johnson KA, Bevan C, Hardy CJ, Coombs DW, Mullins PA, Brown WR. Chronic toxicity/oncogenicity study of styrene in CD-1 mice by inhalation exposure for 104 weeks. J Appl Toxicol 2001; 21:185-98. [PMID: 11404830 DOI: 10.1002/jat.737] [Citation(s) in RCA: 97] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Groups of 70 male and 70 female Charles River CD-1 mice were exposed whole body to styrene vapor at 0, 20, 40, 80 or 160 ppm 6 h per day 5 days per week for 98 weeks (females) or 104 weeks (males). The mice were observed daily; body weights, food and water consumption were measured periodically, a battery of hematological and clinical pathology examinations were conducted at weeks 13, 26, 52, 78 and 98 (females)/104 (males). Ten mice of each gender per group were pre-selected for necropsy after 52 and 78 weeks of exposure and the survivors of the remaining 50 of each gender per group were necropsied after 98 or 104 weeks. An extensive set of organs from the control and high-exposure mice were examined histopathologically, whereas target organs, gross lesions and all masses were examined in all other groups. Styrene had no effect on survival in males. Two high-dose females died (acute liver toxicity) during the first 2 weeks; the remaining exposed females had a slightly higher survival than control mice. Levels of styrene and styrene oxide (SO) in the blood at the end of a 6 h exposure during week 74 were proportional to exposure concentration, except that at 20 ppm the SO level was below the limit of detection. There were no changes of toxicological significance in hematology, clinical chemistry, urinalysis or organ weights. Mice exposed to 80 or 160 ppm gained slightly less weight than the controls. Styrene-related non-neoplastic histopathological changes were found only in the nasal passages and lungs. In the nasal passages of males and females at all exposure concentrations, the changes included respiratory metaplasia of the olfactory epithelium with changes in the underlying Bowman's gland; the severity increased with styrene concentration and duration of exposure. Loss of olfactory nerve fibers was seen in mice exposed to 40, 80 or 160 ppm. In the lungs, there was decreased eosinophilia of Clara cells in the terminal bronchioles and bronchiolar epithelial hyperplasia extending into alveolar ducts. Increased tumor incidence occurred only in the lung. The incidence of bronchioloalveolar adenomas was significantly increased in males exposed to 40, 80 or 160 ppm and in females exposed to 20, 40 and 160 ppm. The increase was seen only after 24 months. In females exposed to 160 ppm, the incidence of bronchiolo-alveolar carcinomas after 24 months was significantly greater than in the controls. No difference in lung tumors between control and styrene-exposed mice was seen in the intensity or degree of immunostaining, the location of tumors relative to bronchioles or histological type (papillary, solid or mixed). It appears that styrene induces an increase in the number of lung tumors seen spontaneously in CD-1 mice.
Collapse
Affiliation(s)
- G Cruzan
- ToxWorks, 1153 Roadstown Rd, Bridgeton, NJ 08302, USA
| | | | | | | | | | | | | | | | | | | |
Collapse
|
16
|
Johanson G, Ernstgård L, Gullstrand E, Löf A, Osterman-Golkar S, Williams CC, Sumner SC. Styrene oxide in blood, hemoglobin adducts, and urinary metabolites in human volunteers exposed to (13)C(8)-styrene vapors. Toxicol Appl Pharmacol 2000; 168:36-49. [PMID: 11000098 DOI: 10.1006/taap.2000.9007] [Citation(s) in RCA: 36] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Styrene is used in the manufacture of plastics and polymers and in the boat-building industry. The major metabolic route for styrene in rats, mice, and humans involves conversion to styrene-7,8-oxide (SO). The purpose of this study was to evaluate blood SO, SO-hemoglobin (SO-Hb) adducts, and urinary metabolites in styrene-exposed human volunteers and to compare these results with data previously obtained for rodents. Four healthy male volunteers were exposed for 2 h during light physical exercise to 50 ppm (13)C(8)-styrene vapor via a face mask. Levels and time profiles of styrene in exhaled air, blood, and urine (analyzed by GC) and urinary excretion patterns of mandelic acid and phenylglyoxylic acid in urine (analyzed by HPLC) were comparable to previously published volunteer studies. Maximum levels of SO in blood (measured by GC-MS) of 2.5-12.2 (average 6.7) nM were seen after 2 h, i.e., in the first sample collected after exposure had ended. The styrene blood level in humans was about 1.5 to 2 times higher than in rats and 4 times higher than in mice for equivalent styrene exposures. In contrast the SO levels in human blood was approximately fourfold lower than in mice. The level of hydroxyphenethylvaline (determined by GC-MS-MS) in pooled blood collected after exposure was estimated as 0.3 pmol/g globin corresponding to a SO-Hb adduct increment of about 0.003 pmol/g and ppmh. NMR analyses of urine showed that a major portion (> 95%) of the excreted (13)C-derived metabolites was derived from hydrolysis of SO, while only a small percentage of the excreted metabolites (< 5%) was derived from metabolism via phenylacetaldehyde. Signals consistent with metabolites derived from other pathways of styrene metabolism in rodents (such as glutathione conjugation with SO or ring epoxidation) were not detected.
Collapse
Affiliation(s)
- G Johanson
- Toxicology and Risk Assessment, National Institute for Working Life, Stockholm, Sweden
| | | | | | | | | | | | | |
Collapse
|
17
|
Abstract
Damage of DNA films after reaction with styrene oxide was detected using derivative square wave voltammetry. Double-stranded (ds) DNA films with initially low backgrounds developed oxidation peaks for DNA bases during incubation with styrene oxide. Films were prepared on pyrolytic graphite (PG) electrodes by casting mixtures of DNA with the poly(ester sulfonic acid) ionomer Eastman AQ38S or by covalent binding of DNA onto oxidized PG. While both types of films gave oxidation peaks in the region 0.6-1.1 V vs SCE after incubations with styrene oxide, DNA/AQ films gave the best signal-to-background ratios. Damage of DNA by reaction with styrene oxide under the electrode incubation conditions was confirmed by capillary electrophoresis. Total integrals of oxidation peaks increased with time of incubation with styrene oxide. Relative peak heights depended on the type of DNA in the order calf thymus ds DNA > salmon sperm ds DNA > supercoiled ds DNA > highly polymerized calf thymus ds DNA.
Collapse
Affiliation(s)
- J Mbindyo
- Department of Chemistry, University of Connecticut, Storrs 06269-3060, USA
| | | | | | | | | |
Collapse
|
18
|
Sumner SC, Cattley RC, Asgharian B, Janszen DB, Fennell TR. Evaluation of the metabolism and hepatotoxicity of styrene in F344 rats, B6C3F1 mice, and CD-1 mice following single and repeated inhalation exposures. Chem Biol Interact 1997; 106:47-65. [PMID: 9305408 DOI: 10.1016/s0009-2797(97)00054-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Styrene is used for the manufacture of plastics and polymers. The metabolism and hepatotoxicity (mice only) of styrene was compared in male B6C3F1 mice, CD-1 mice, and F344 rats to evaluate biochemical mechanisms of toxicity. Rats and mice were exposed to 250 ppm styrene for 6 h/day for 1 to 5 days, and liver (mice only) and blood were collected following each day of exposure. Mortality and increased serum alanine aminotransferase (ALT) activity were observed in mice but not in rats. Hepatotoxicity in B6C3F1 mice was characterized by severe centrilobular congestion after one exposure followed by acute centrilobular necrosis. Hepatotoxicity was delayed by 1 day in CD-1 mice, and the increase in ALT and degree of necrosis was less than observed for B6C3F1 mice. Following exposure to unlabeled styrene for 0, 2, or 4 days, rats and mice were exposed to [7-14C]-styrene (60 microCi/mmol) for 6 h. Urine, feces, and expired air were collected for up to 48 h. Most styrene-derived radioactivity was excreted in urine. The time-course of urinary excretion indicates that rats and CD-1 mice eliminated radioactivity at a faster rate than B6C3F1 mice following a single 250 ppm exposure, consistent with a greater extent of liver injury for B6C3F1 mice. The elimination rate following 3 or 5 days of exposure was similar for rats and both mouse strains. Following three exposures, the total radioactivity eliminated in excreta was elevated over that measured for one exposure for both mouse strains. An increased excretion of metabolites on multiple exposure is consistent with the absence of ongoing acute necrosis following 4 to 5 daily exposures. These data indicate that an induction in styrene metabolism occurs after multiple exposures, resulting in an increased uptake and/or clearance for styrene.
Collapse
Affiliation(s)
- S C Sumner
- Chemical Industry Institute of Toxicology, Research Triangle Park, NC 27709, USA
| | | | | | | | | |
Collapse
|
19
|
Abstract
2-Methylpropene (MP) or isobutene is a gaseous chemical used on a large scale in the synthetic rubber industry. The present review covers the rather scarce literature on MP with respect to its metabolic fate and toxicity in laboratory animals and humans. It has been shown both in vivo and in vitro that MP is metabolized to the primary metabolite 2-methyl-1,2-epoxypropane (MEP) by rodent and human liver tissue. The formation of this reactive epoxide intermediate is catalyzed by CYP2E1, while epoxide hydrolase and glutathione S-transferase appear to be involved in its inactivation. In rats, the capacity to absorb and metabolize MP is saturable. MP is oxidized to compounds that are mainly excreted in urine. Data indicate that rodents can tolerate low levels of MP without apparent toxicity. The primary metabolite MEP, however, is able to produce genetic damage in both prokaryotic and eukaryotic cells in vitro. MP is thus not toxic per se but elicits metabolic activation to become potentially harmful. Consequently, the balance between formation and detoxification of MEP plays a key role in determining the potential toxicity of the parent compound. Obviously, further research, including repeated exposure toxicity studies, is required before an estimation of the risk for man can be made.
Collapse
Affiliation(s)
- M Cornet
- Department of Toxicology, Vrije Universiteit Brussel, Belgium
| | | |
Collapse
|