1
|
Song L, Golman M, Abraham AC, Zelzer E, Thomopoulos S. A role for TGFβ signaling in Gli1+ tendon and enthesis cells. FASEB J 2024; 38:e23568. [PMID: 38522021 PMCID: PMC10962263 DOI: 10.1096/fj.202301452r] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 02/16/2024] [Accepted: 03/07/2024] [Indexed: 03/25/2024]
Abstract
The development of musculoskeletal tissues such as tendon, enthesis, and bone relies on proliferation and differentiation of mesenchymal progenitor cells. Gli1+ cells have been described as putative stem cells in several tissues and are presumed to play critical roles in tissue formation and maintenance. For example, the enthesis, a fibrocartilage tissue that connects tendon to bone, is mineralized postnatally by a pool of Gli1+ progenitor cells. These cells are regulated by hedgehog signaling, but it is unclear if TGFβ signaling, necessary for tenogenesis, also plays a role in their behavior. To examine the role of TGFβ signaling in Gli1+ cell function, the receptor for TGFβ, TbR2, was deleted in Gli1-lineage cells in mice at P5. Decreased TGFβ signaling in these cells led to defects in tendon enthesis formation by P56, including defective bone morphometry underlying the enthesis and decreased mechanical properties. Immunohistochemical staining of these Gli1+ cells showed that loss of TGFβ signaling reduced proliferation and increased apoptosis. In vitro experiments using Gli1+ cells isolated from mouse tail tendons demonstrated that TGFβ controls cell proliferation and differentiation through canonical and non-canonical pathways and that TGFβ directly controls the tendon transcription factor scleraxis by binding to its distant enhancer. These results have implications in the development of treatments for tendon and enthesis pathologies.
Collapse
Affiliation(s)
- Lee Song
- Department of Orthopedic Surgery, Columbia University, New York, NY10032, USA
| | - Mikhail Golman
- Department of Orthopedic Surgery, Columbia University, New York, NY10032, USA
- Department of Biomedical Engineering, Columbia University, New York, NY10027, USA
| | - Adam C. Abraham
- Department of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Elazar Zelzer
- Department of Molecular Genetics, Weizmann Institute of Science, Israel
| | - Stavros Thomopoulos
- Department of Orthopedic Surgery, Columbia University, New York, NY10032, USA
- Department of Biomedical Engineering, Columbia University, New York, NY10027, USA
| |
Collapse
|
2
|
Kent RN, Jewett ME, Buck TP, Said M, Hold LA, Crawford EA, Killian ML, Abraham AC, Huang AH, Baker BM. Engineered Microenvironmental Cues from Fiber-Reinforced Hydrogel Composites Drive Tenogenesis and Aligned Collagen Deposition. Adv Healthc Mater 2024:e2400529. [PMID: 38441411 DOI: 10.1002/adhm.202400529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/25/2024]
Abstract
Effective tendon regeneration following injury is contingent on appropriate differentiation of recruited cells and deposition of mature, aligned, collagenous extracellular matrix that can withstand the extreme mechanical demands placed on the tissue. As such, myriad biomaterial approaches have been explored to provide biochemical and physical cues that encourage tenogenesis and template aligned matrix deposition in lieu of dysfunctional scar tissue formation. Fiber-reinforced hydrogels present an ideal biomaterial system toward this end given their transdermal injectability, tunable stiffness over a range amenable to tenogenic differentiation of progenitors, and capacity for modular inclusion of biochemical cues. Here, tunable and modular, fiber-reinforced, synthetic hydrogels are employed to elucidate salient microenvironmental determinants of tenogenesis and aligned collagen deposition by tendon progenitor cells. Transforming growth factor β3 drives a cell fate switch toward pro-regenerative or pro-fibrotic phenotypes, which can be biased toward the former by culture in softer microenvironments or inhibition of the RhoA/ROCK activity. Furthermore, studies demonstrate that topographical anisotropy in fiber-reinforced hydrogels critically mediates the alignment of de novo collagen fibrils, reflecting native tendon architecture. These findings inform the design of cell-free, injectable, synthetic hydrogels for tendon tissue regeneration and, likely, that of a range of load-bearing connective tissues. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Robert N Kent
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Maggie E Jewett
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Trevor P Buck
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Mohamed Said
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA
| | - LeeAnn A Hold
- Department of Orthopedic Surgery, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Eileen A Crawford
- Department of Orthopedic Surgery, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Megan L Killian
- Department of Orthopedic Surgery, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Adam C Abraham
- Department of Orthopedic Surgery, University of Michigan, Ann Arbor, MI, 48109, USA
| | - Alice H Huang
- Department of Orthopedic Surgery, Columbia University, New York, NY, 10027, USA
| | - Brendon M Baker
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA
- Department of Chemical Engineering, University of Michigan, Ann Arbor, MI, 48109, USA
| |
Collapse
|
3
|
Steltzer SS, Abraham AC, Killian ML. Interfacial Tissue Regeneration with Bone. Curr Osteoporos Rep 2024:10.1007/s11914-024-00859-1. [PMID: 38358401 DOI: 10.1007/s11914-024-00859-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/29/2024] [Indexed: 02/16/2024]
Abstract
PURPOSE OF REVIEW Interfacial tissue exists throughout the body at cartilage-to-bone (osteochondral interface) and tendon-to-bone (enthesis) interfaces. Healing of interfacial tissues is a current challenge in regenerative approaches because the interface plays a critical role in stabilizing and distributing the mechanical stress between soft tissues (e.g., cartilage and tendon) and bone. The purpose of this review is to identify new directions in the field of interfacial tissue development and physiology that can guide future regenerative strategies for improving post-injury healing. RECENT FINDINGS Cues from interfacial tissue development may guide regeneration including biological cues such as cell phenotype and growth factor signaling; structural cues such as extracellular matrix (ECM) deposition, ECM, and cell alignment; and mechanical cues such as compression, tension, shear, and the stiffness of the cellular microenvironment. In this review, we explore new discoveries in the field of interfacial biology related to ECM remodeling, cellular metabolism, and fate. Based on emergent findings across multiple disciplines, we lay out a framework for future innovations in the design of engineered strategies for interface regeneration. Many of the key mechanisms essential for interfacial tissue development and adaptation have high potential for improving outcomes in the clinic.
Collapse
Affiliation(s)
- Stephanie S Steltzer
- Department of Orthopaedic Surgery, University of Michigan Medical School, Ann Arbor, MI, USA
- Department of Molecular & Integrative Physiology, University of Michigan Medical School, Ann Arbor, MI, USA
| | - Adam C Abraham
- Department of Orthopaedic Surgery, University of Michigan Medical School, Ann Arbor, MI, USA
| | - Megan L Killian
- Department of Orthopaedic Surgery, University of Michigan Medical School, Ann Arbor, MI, USA.
- Department of Molecular & Integrative Physiology, University of Michigan Medical School, Ann Arbor, MI, USA.
| |
Collapse
|
4
|
Burt KG, Kim MKM, Viola DC, Abraham AC, Chahine NO. Nuclear Factor Kappa B Over-Activation in the Intervertebral Disc Leads to Macrophage Recruitment and Severe Disc Degeneration. bioRxiv 2023:2023.08.07.552274. [PMID: 37609194 PMCID: PMC10441339 DOI: 10.1101/2023.08.07.552274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
Objective Low back pain (LBP) is the leading cause of global disability and is thought to be driven primarily by intervertebral disc (IVD) degeneration (DD). Persistent upregulation of catabolic enzymes and inflammatory mediators have been associated with severe cases of DD. Nuclear factor kappa B (NF-κB) is a master transcription regulator of immune responses and is over expressed during inflammatory-driven musculoskeletal diseases, including DD. However, its role in triggering DD is unknown. Therefore, this study investigated the effect of NF-κB pathway over-activation on IVD integrity and DD pathology. Methods Using skeletally mature mouse model, we genetically targeted IVD cells for canonical NF-κB pathway activation via expression of a constitutively active form of inhibitor of κB kinase B (IKKβ), and assessed changes in IVD cellularity, structural integrity including histology, disc height, and extracellular matrix (ECM) biochemistry, biomechanics, expression of inflammatory, catabolic, and neurotropic mediators, and changes in macrophage subsets, longitudinally up to 6-months post activation. Results Prolonged NF-κB activation led to severe structural degeneration, with a loss of glycosaminoglycan (GAG) content and complete loss of nucleus pulposus (NP) cellularity. Structural and compositional changes decreased IVD height and compressive mechanical properties with prolonged NF-κB activation. These alterations were accompanied by increases in gene expression of inflammatory molecules ( Il1b, Il6, Nos2 ), chemokines ( Mcp1 , Mif ), catabolic enzymes ( Mmp3, Mmp9, Adamts4 ), and neurotrophic factors ( Bdnf , Ngf ) within IVD tissue. Increased recruitment of activated F4/80 + macrophages exhibited a greater abundance of pro-inflammatory (CD38 + ) over inflammatory-resolving (CD206 + ) macrophage subsets in the IVD, with temporal changes in the relative abundance of macrophage subsets over time, providing evidence for temporal regulation of macrophage polarization in DD in vivo, where macrophages participate in resolving the inflammatory cascade but promote fibrotic transformation of the IVD matrix. We further show that NF-κB driven secretory factors from IVD cells increase macrophage migration and inflammatory activation, and that the secretome of inflammatory-resolving macrophages mitigates effects of NF-κB overactivation. Conclusion Overall the observed results suggest prolonged NF-κB activation can induce severe DD, acting through increases in inflammatory cytokines, chemotactic proteins, catabolic enzymes, and the recruitment and inflammatory activation of a macrophage cell populations, that can be mitigated with inflammatory-resolving macrophage secretome.
Collapse
|
5
|
Ganji E, Lamia SN, Stepanovich M, Whyte N, Goulet RW, Abraham AC, Killian ML. Optogenetic-induced muscle loading leads to mechanical adaptation of the Achilles tendon enthesis in mice. Sci Adv 2023; 9:eadf4683. [PMID: 37352350 PMCID: PMC10289645 DOI: 10.1126/sciadv.adf4683] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Accepted: 05/17/2023] [Indexed: 06/25/2023]
Abstract
Skeletal shape depends on the transmission of contractile muscle forces from tendon to bone across the enthesis. Loss of muscle loading impairs enthesis development, yet little is known if and how the postnatal enthesis adapts to increased loading. Here, we studied adaptations in enthesis structure and function in response to increased loading, using optogenetically induced muscle contraction in young (i.e., growth) and adult (i.e., mature) mice. Daily bouts of unilateral optogenetic loading in young mice led to radial calcaneal expansion and warping. This also led to a weaker enthesis with increased collagen damage in young tendon and enthisis, with little change in adult mice. We then used RNA sequencing to identify the pathways associated with increased mechanical loading during growth. In tendon, we found enrichment of glycolysis, focal adhesion, and cell-matrix interactions. In bone, we found enrichment of inflammation and cell cycle. Together, we demonstrate the utility of optogenetic-induced muscle contraction to elicit in vivo adaptation of the enthesis.
Collapse
Affiliation(s)
- Elahe Ganji
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Ave., Urbana, IL 61801, USA
- Department of Biomedical Engineering, University of Delaware, 540 S. College Ave., Newark, DE 19713, USA
| | - Syeda N. Lamia
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
- Department of Mechanical Engineering, University of Michigan, 2350 Hayward St., Ann Arbor, MI 48109, USA
| | - Matthew Stepanovich
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
| | - Noelle Whyte
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
| | - Robert W. Goulet
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
| | - Adam C. Abraham
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
| | - Megan L. Killian
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, MI 48109, USA
- Department of Biomedical Engineering, University of Delaware, 540 S. College Ave., Newark, DE 19713, USA
| |
Collapse
|
6
|
Ganji E, Lamia SN, Stepanovich M, Whyte N, Abraham AC, Killian ML. Optogenetic-Induced Muscle Loading Leads to Mechanical Adaptation of the Achilles Tendon Enthesis in Mice. bioRxiv 2023:2023.04.11.536376. [PMID: 37090593 PMCID: PMC10120626 DOI: 10.1101/2023.04.11.536376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/25/2023]
Abstract
The growth of the skeleton depends on the transmission of contractile muscle forces from tendon to bone across the extracellular matrix-rich enthesis. Loss of muscle loading leads to significant impairments in enthesis development. However, little is known about how the enthesis responds to increased loading during postnatal growth. To study the cellular and matrix adaptations of the enthesis in response to increased muscle loading, we used optogenetics to induce skeletal muscle contraction and unilaterally load the Achilles tendon and enthesis in young (i.e., during growth) and adult (i.e., mature) mice. In young mice, daily bouts of unilateral optogenetic loading led to expansion of the calcaneal apophysis and growth plate, as well as increased vascularization of the normally avascular enthesis. Daily loading bouts, delivered for 3 weeks, also led to a mechanically weaker enthesis with increased molecular-level accumulation of collagen damage in young mice. However, adult mice did not exhibit impaired mechanical properties or noticeable structural adaptations to the enthesis. We then focused on the transcriptional response of the young tendon and bone following optogenetic-induced loading. After 1 or 2 weeks of loading, we identified, in tendon, transcriptional activation of canonical pathways related to glucose metabolism (glycolysis) and inhibited pathways associated with cytoskeletal remodeling (e.g., RHOA and CREB signaling). In bone, we identified activation of inflammatory signaling (e.g., NFkB and STAT3 signaling) and inhibition of ERK/MAPK and PTEN signaling. Thus, we have demonstrated the utility of optogenetic-induced skeletal muscle contraction to elicit structural, functional, and molecular adaptation of the enthesis in vivo especially during growth.
Collapse
Affiliation(s)
- Elahe Ganji
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, Michigan, 48109
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, 405 North Mathews Ave., Urbana, Illinois, 61801
| | - Syeda N Lamia
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, Michigan, 48109
- Department of Mechanical Engineering, University of Michigan, 2350 Hayward St., Ann Arbor, Michigan, 48109
| | - Matthew Stepanovich
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, Michigan, 48109
| | - Noelle Whyte
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, Michigan, 48109
| | - Adam C Abraham
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, Michigan, 48109
| | - Megan L Killian
- Department of Orthopaedic Surgery, Michigan Medicine, University of Michigan, 109 Zina Pitcher Pl., Ann Arbor, Michigan, 48109
- Department of Biomedical Engineering, University of Delaware, 540 S. College Ave., Newark, Delaware, 19713
| |
Collapse
|
7
|
Ahmady A, Rosenthal L, Abraham AC, Parker B, Brooks JT, Cahill PJ, Smith JT, Sponseller PD, Sturm PF, Li Y. Comparison of Distal Spine Anchors and Distal Pelvic Anchors in Children With Hypotonic Neuromuscular Scoliosis Treated With Growth-friendly Instrumentation. J Pediatr Orthop 2023; 43:e319-e325. [PMID: 36827606 DOI: 10.1097/bpo.0000000000002376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/26/2023]
Abstract
BACKGROUND Lower preoperative pelvic obliquity (PO) and L5 tilt have been associated with good radiographic outcomes when the fusion ended short of the pelvis in children with neuromuscular scoliosis (NMS). Our purpose was to identify indications to exclude the pelvis in children with hypotonic NMS treated with growth-friendly instrumentation. METHODS This was a multicenter retrospective review. Children with spinal muscular atrophy and muscular dystrophy treated with dual traditional growing rod, magnetically controlled growing rod, or vertical expandable prosthetic titanium rib with minimum 2-year follow-up after the index surgery were identified. RESULTS A total of 125 patients met the inclusion criteria. Thirty-eight patients had distal spine anchors (DSAs) and 87 patients had distal pelvic anchors (DPAs) placed at the index surgery. Demographics and length of follow-up were similar between the groups but there was a greater percentage of DPA patients who were nonambulatory [79 patients (91%) vs. 18 patients (47%), P <0.0001]. Preindex radiographic measures were similar except the DSA patients had a lower PO (11 vs. 19 degrees, P =0.0001) and L5 tilt (8 vs. 12 degrees, P =0.001). Postindex and most recent radiographic data were comparable between the groups. There was no difference in the complication and unplanned returns to the operating room rates.Subanalysis of the DSA group based on ambulatory status showed similar radiographic measures except the ambulatory patients had a lower PO at all time points (preindex: 5 vs. 16 degrees, P =0.011; postindex: 6 vs. 10 degrees, P =0.045; most recent follow-up: 5 vs. 14 degrees, P =0.028). Only 1 ambulatory DSA patient had a PO ≥10 degrees at most recent follow-up compared with 6 nonambulatory DSA patients. Three (8%) DSA patients, all nonambulatory, underwent extension of their instrumentation to the pelvis. CONCLUSIONS Pelvic fixation should be strongly considered in nonambulatory children with hypotonic NMS treated with growth-friendly instrumentation. At intermediate-term follow-up, revision surgery to include the pelvis was rare but DSAs do not seem effective at maintaining control of PO in nonambulatory patients. DSA and DPA were equally effective at maintaining major curve control, and complication and unplanned returns to the operating room rates were similar. LEVEL OF EVIDENCE Level III-therapeutic.
Collapse
Affiliation(s)
- Arya Ahmady
- Department of Orthopaedic Surgery, C.S. Mott Children's Hospital, Michigan Medicine, Ann Arbor, MI
| | - Lindsay Rosenthal
- Department of Orthopaedic Surgery, C.S. Mott Children's Hospital, Michigan Medicine, Ann Arbor, MI
| | - Adam C Abraham
- Department of Orthopaedic Surgery, C.S. Mott Children's Hospital, Michigan Medicine, Ann Arbor, MI
| | - Bianca Parker
- Wayne State University School of Medicine, Detroit, MI
| | - Jaysson T Brooks
- Department of Orthopaedic Surgery, Texas Scottish Rite Hospital for Children, University of Texas Southwestern, Dallas, TX
| | - Patrick J Cahill
- Department of Orthopaedic Surgery, Children's Hospital of Philadelphia, Philadelphia, PA
| | - John T Smith
- Department of Orthopaedic Surgery, Primary Children's Hospital, University of Utah, Salt Lake City, UT
| | - Paul D Sponseller
- Department of Orthopaedic Surgery, Johns Hopkins Medicine, Baltimore, MD
| | - Peter F Sturm
- Department of Orthopaedic Surgery, Cincinnati Children's Hospital Medical Center, Cincinnati, OH
| | - Ying Li
- Department of Orthopaedic Surgery, C.S. Mott Children's Hospital, Michigan Medicine, Ann Arbor, MI
| |
Collapse
|
8
|
Abraham AC, Fang F, Golman M, Oikonomou P, Thomopoulos S. The role of loading in murine models of rotator cuff disease. J Orthop Res 2022; 40:977-986. [PMID: 34081350 PMCID: PMC8639823 DOI: 10.1002/jor.25113] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 04/07/2021] [Accepted: 05/31/2021] [Indexed: 02/04/2023]
Abstract
Rotator cuff disease pathogenesis is associated with intrinsic (e.g., age, joint laxity, muscle weakness) and extrinsic (e.g., mechanical load, fatigue) factors that lead to chronic degeneration of the cuff tissues. However, etiological studies are difficult to perform in patients due to the long duration of disease onset and progression. Therefore, the purpose of this study was to determine the effects of altered joint loading on the rotator cuff. Mice were subjected to one of three load-dependent rotator cuff tendinopathy models: underuse loading, achieved by injecting botulinum toxin-A into the supraspinatus muscle; overuse loading, achieved using downhill treadmill running; destabilization loading, achieved by surgical excision of the infraspinatus tendon. All models were compared to cage activity animals. Whole joint function was assessed longitudinally using gait analysis. Tissue-scale structure and function were determined using microCT, tensile testing, and histology. The molecular response of the supraspinatus tendon and enthesis was determined by measuring the expression of 84 wound healing-associated genes. Underuse and destabilization altered forepaw weight-bearing, decreased tendon-to-bone attachment strength, decreased mineral density of the humeral epiphysis, and reduced tendon strength. Transcriptional activity of the underuse group returned to baseline levels by 4 weeks, while destabilization had significant upregulation of inflammation, growth factors, and extracellular matrix remodeling genes. Surprisingly, overuse activity caused changes in walking patterns, increased tendon stiffness, and primarily suppressed expression of wound healing-related genes. In summary, the tendinopathy models demonstrated how divergent muscle loading can result in clinically relevant alterations in rotator cuff structure, function, and gene expression.
Collapse
Affiliation(s)
- Adam C. Abraham
- University of Michigan, Department of Orthopaedic Surgery, Biomedical Science Research Building, 109 Zina Pitcher Pl, Ann Arbor, MI 48109, USA,Corresponding author Adam C. Abraham, Ph.D., Research Investigator, University of Michigan, Department of Orthopaedic Surgery, Ann Arbor, MI 48109, USA,
| | - Fei Fang
- Columbia University Irving Medical Center, Department of Orthopaedic Surgery, New York, NY 10032, USA
| | - Mikhail Golman
- Columbia University, Department of Biomedical Engineering, New York, NY 10027
| | | | - Stavros Thomopoulos
- Columbia University Irving Medical Center, Department of Orthopaedic Surgery, New York, NY 10032, USA,Columbia University, Department of Biomedical Engineering, New York, NY 10027
| |
Collapse
|
9
|
Golman M, Abraham AC, Kurtaliaj I, Marshall BP, Hu YJ, Schwartz AG, Guo XE, Birman V, Thurner PJ, Genin GM, Thomopoulos S. Toughening mechanisms for the attachment of architectured materials: The mechanics of the tendon enthesis. Sci Adv 2021; 7:eabi5584. [PMID: 34826240 PMCID: PMC8626067 DOI: 10.1126/sciadv.abi5584] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 10/06/2021] [Indexed: 05/09/2023]
Abstract
Architectured materials offer tailored mechanical properties but are limited in engineering applications due to challenges in maintaining toughness across their attachments. The enthesis connects tendon and bone, two vastly different architectured materials, and exhibits toughness across a wide range of loadings. Understanding the mechanisms by which this is achieved could inform the development of engineered attachments. Integrating experiments, simulations, and previously unexplored imaging that enabled simultaneous observation of mineralized and unmineralized tissues, we identified putative mechanisms of enthesis toughening in a mouse model and then manipulated these mechanisms via in vivo control of mineralization and architecture. Imaging uncovered a fibrous architecture within the enthesis that controls trade-offs between strength and toughness. In vivo models of pathology revealed architectural adaptations that optimize these trade-offs through cross-scale mechanisms including nanoscale protein denaturation, milliscale load-sharing, and macroscale energy absorption. Results suggest strategies for optimizing architecture for tough bimaterial attachments in medicine and engineering.
Collapse
Affiliation(s)
- Mikhail Golman
- Department of Orthopedic Surgery, Columbia University, New York, NY 10032, USA
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Adam C. Abraham
- Department of Orthopedic Surgery, Columbia University, New York, NY 10032, USA
| | - Iden Kurtaliaj
- Department of Orthopedic Surgery, Columbia University, New York, NY 10032, USA
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Brittany P. Marshall
- Department of Orthopedic Surgery, Columbia University, New York, NY 10032, USA
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Yizhong Jenny Hu
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Andrea G. Schwartz
- NSF Science and Technology Center for Engineering Mechanobiology, Washington University, St. Louis, MO 63130, USA
| | - X. Edward Guo
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| | - Victor Birman
- Missouri University of Science and Technology, Rolla, MO 65409, USA
| | - Philipp J. Thurner
- Institute of Lightweight Design and Structural Biomechanics, Vienna University of Technology, Vienna, Austria
| | - Guy M. Genin
- NSF Science and Technology Center for Engineering Mechanobiology, Washington University, St. Louis, MO 63130, USA
| | - Stavros Thomopoulos
- Department of Orthopedic Surgery, Columbia University, New York, NY 10032, USA
- Department of Biomedical Engineering, Columbia University, New York, NY 10027, USA
| |
Collapse
|
10
|
Moser HL, Abraham AC, Howell K, Laudier D, Zumstein MA, Galatz LM, Huang AH. Cell lineage tracing and functional assessment of supraspinatus tendon healing in an acute repair murine model. J Orthop Res 2021; 39:1789-1799. [PMID: 32497311 PMCID: PMC7714710 DOI: 10.1002/jor.24769] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2020] [Revised: 04/27/2020] [Accepted: 05/25/2020] [Indexed: 02/04/2023]
Abstract
Rotator cuff supraspinatus tendon injuries are common with high rates of anatomic failure after surgical repair. The purpose of the study was to define clinically relevant features of a mouse model of supraspinatus tendon injury to determine painful, functional, and structural outcomes; we further investigated two cell populations mediating healing using genetic lineage tracing after full detachment and repair of the supraspinatus tendon in mice. The pain was assessed using the mouse grimace scale and function by gait analysis and tensile testing. Histological and microCT analyses were used to determine enthesis/tendon and bone structure, respectively. Lineage tracing was carried out using inducible Cre lines for ScxCreERT2 (tendon cells) and αSMACreERT2 (myofibroblasts and mesenchymal progenitors). Mice only expressed pain transiently after surgery despite long-term impairment of functional and structural properties. Gait, tensile mechanical properties, and bone properties were significantly reduced after injury and repair. Lineage tracing showed relatively few Scx lin tendon cells while αSMA lin cells contributed strongly to scar formation. Despite surgical reattachment of healthy tendon, lineage tracing revealed poor preservation of supraspinatus tendon after acute injury and loss of tendon structure, suggesting that tendon degeneration is also a key impediment of successful rotator cuff repair. Scar formation after surgery is mediated largely by αSMA lin cells and results in permanently reduced functional and structural properties.
Collapse
Affiliation(s)
- Helen L. Moser
- Icahn School of Medicine at Mount Sinai, Department of Orthopaedics, 1 Gustave Levy Place, Box 1188, New York, NY 10029, USA,Inselspital, Bern University Hospital, University of Bern, Shoulder, Elbow and Orthopaedic Sports Medicine, Department of Orthopaedic Surgery and Traumatology, 3010 Bern, Switzerland
| | - Adam C. Abraham
- Columbia University Irving Medical Center, Department of Orthopedic Surgery, New York, NY 10032, USA
| | - Kristen Howell
- Icahn School of Medicine at Mount Sinai, Department of Orthopaedics, 1 Gustave Levy Place, Box 1188, New York, NY 10029, USA
| | - Damien Laudier
- Icahn School of Medicine at Mount Sinai, Department of Orthopaedics, 1 Gustave Levy Place, Box 1188, New York, NY 10029, USA
| | - Matthias A. Zumstein
- Inselspital, Bern University Hospital, University of Bern, Shoulder, Elbow and Orthopaedic Sports Medicine, Department of Orthopaedic Surgery and Traumatology, 3010 Bern, Switzerland,Shoulder, Elbow and Orthopaedic Sports Medicine, Orthopaedics Sonnenhof, 3006 Bern, Switzerland
| | - Leesa M. Galatz
- Icahn School of Medicine at Mount Sinai, Department of Orthopaedics, 1 Gustave Levy Place, Box 1188, New York, NY 10029, USA
| | - Alice H. Huang
- Icahn School of Medicine at Mount Sinai, Department of Orthopaedics, 1 Gustave Levy Place, Box 1188, New York, NY 10029, USA
| |
Collapse
|
11
|
Abraham AC, Shah SA, Golman M, Song L, Li X, Kurtaliaj I, Akbar M, Millar NL, Abu-Amer Y, Galatz LM, Thomopoulos S. Targeting the NF-κB signaling pathway in chronic tendon disease. Sci Transl Med 2020; 11:11/481/eaav4319. [PMID: 30814338 DOI: 10.1126/scitranslmed.aav4319] [Citation(s) in RCA: 93] [Impact Index Per Article: 23.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2018] [Accepted: 01/31/2019] [Indexed: 01/20/2023]
Abstract
Tendon disorders represent the most common musculoskeletal complaint for which patients seek medical attention; inflammation drives tendon degeneration before tearing and impairs healing after repair. Clinical evidence has implicated the nuclear factor kappa-light-chain-enhancer of activated B cells (NF-κB) pathway as a correlate of pain-free return to function after surgical repair. However, it is currently unknown whether this response is a reaction to or a driver of pathology. Therefore, we aimed to understand the clinically relevant involvement of the NF-κB pathway in tendinopathy, to determine its potential causative roles in tendon degeneration, and to test its potential as a therapeutic candidate. Transcriptional profiling of early rotator cuff tendinopathy identified increases in NF-κB signaling, including increased expression of the regulatory serine kinase subunit IKKβ, which plays an essential role in inflammation. Using cre-mediated overexpression of IKKβ in tendon fibroblasts, we observed degeneration of mouse rotator cuff tendons and the adjacent humeral head. These changes were associated with increases in proinflammatory cytokines and innate immune cells within the joint. Conversely, genetic deletion of IKKβ in tendon fibroblasts partially protected mice from chronic overuse-induced tendinopathy. Furthermore, conditional knockout of IKKβ improved outcomes after surgical repair, whereas overexpression impaired tendon healing. Accordingly, targeting of the IKKβ/NF-κB pathway in tendon stromal cells may offer previously unidentified therapeutic approaches in the management of human tendon disorders.
Collapse
Affiliation(s)
- Adam C Abraham
- Department of Orthopedic Surgery, Columbia University, 650 W 168th St, New York, NY 10032, USA
| | - Shivam A Shah
- Department of Biomedical Engineering, Washington University in St. Louis, 1 Brookings Drive, St. Louis, MO 63130, USA
| | - Mikhail Golman
- Department of Biomedical Engineering, Columbia University, 1210 Amsterdam Ave, New York, NY 10027, USA
| | - Lee Song
- Department of Orthopedic Surgery, Columbia University, 650 W 168th St, New York, NY 10032, USA
| | - Xiaoning Li
- Department of Orthopedic Surgery, Columbia University, 650 W 168th St, New York, NY 10032, USA
| | - Iden Kurtaliaj
- Department of Biomedical Engineering, Columbia University, 1210 Amsterdam Ave, New York, NY 10027, USA
| | - Moeed Akbar
- Institute of Infection, Immunity and Inflammation, College of Medicine, Veterinary and Life Sciences, University of Glasgow, 120 University Ave., Glasgow, Scotland G12 8TA, UK
| | - Neal L Millar
- Institute of Infection, Immunity and Inflammation, College of Medicine, Veterinary and Life Sciences, University of Glasgow, 120 University Ave., Glasgow, Scotland G12 8TA, UK
| | - Yousef Abu-Amer
- Departments of Orthopedic Surgery and Cell Biology and Physiology, Washington University in St. Louis, 660 S. Euclid Ave., St. Louis, MO 63110, USA.,Shriners Hospital for Children, 4400 Clayton Ave, St. Louis, MO 63110, USA
| | - Leesa M Galatz
- Department of Orthopedic Surgery, Mount Sinai, 5 E 98th St., New York, NY 10029, USA
| | - Stavros Thomopoulos
- Department of Orthopedic Surgery, Columbia University, 650 W 168th St, New York, NY 10032, USA. .,Department of Biomedical Engineering, Columbia University, 1210 Amsterdam Ave, New York, NY 10027, USA
| |
Collapse
|
12
|
Abstract
Tendon disorders are common, affect people of all ages, and are often debilitating. Standard treatments, such as anti-inflammatory drugs, rehabilitation, and surgical repair, often fail. In order to define tendon function and demonstrate efficacy of new treatments, the mechanical properties of tendons from animal models must be accurately determined. Murine animal models are now widely used to study tendon disorders and evaluate novel treatments for tendinopathies; however, determining the mechanical properties of mouse tendons has been challenging. In this study, a new system was developed for tendon mechanical testing that includes 3D-printed fixtures that exactly match the anatomies of the humerus and calcaneus to mechanically test supraspinatus tendons and Achilles tendons, respectively. These fixtures were developed using 3D reconstructions of native bone anatomy, solid modeling, and additive manufacturing. The new approach eliminated artifactual gripping failures (e.g., failure at the growth plate failure rather than in the tendon), decreased overall testing time, and increased reproducibility. Furthermore, this new method is readily adaptable for testing other murine tendons and tendons from other animals.
Collapse
Affiliation(s)
- Iden Kurtaliaj
- Department of Orthopedic Surgery, Columbia University; Department of Biomedical Engineering, Columbia University
| | - Mikhail Golman
- Department of Orthopedic Surgery, Columbia University; Department of Biomedical Engineering, Columbia University
| | | | - Stavros Thomopoulos
- Department of Orthopedic Surgery, Columbia University; Department of Biomedical Engineering, Columbia University;
| |
Collapse
|
13
|
McAndrew CM, Agarwalla A, Abraham AC, Feuchtbaum E, Ricci WM, Tang SY. Local bone quality measurements correlates with maximum screw torque at the femoral diaphysis. Clin Biomech (Bristol, Avon) 2018; 52:95-99. [PMID: 29407864 PMCID: PMC5835210 DOI: 10.1016/j.clinbiomech.2018.01.016] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2017] [Revised: 01/17/2018] [Accepted: 01/19/2018] [Indexed: 02/07/2023]
Abstract
BACKGROUND Successful fracture fixation depends critically on the stability of the screw-bone interface. Maximum achievable screw torque reflects the competence of this interface, but it cannot be quantified prior to screw stripping. Typically, the surgeon relies on the patients' bone mineral density and radiographs, along with experience and tactile feedback to assess whether sufficient compression can be generated by the screw and bone. However, the local bone quality would also critically influence the strength of the bone-screw interface. We investigated whether Reference Point Indentation can provide quantitative local bone quality measures that can inform subsequent screw-bone competence. METHODS We examined the associations between the maximum screw torque that can be achieved using 3.5 mm, 4.5 mm, and 6.5 mm diameter stainless steel screws at the distal femoral metaphysis and mid-diaphysis from 20 cadavers, with the femoral neck bone mineral density and the local measures of bone quality using Reference Point Indentation. FINDINGS Indentation Distance Increase, a measure of bone's resistance to microfracture, correlated with the maximum screw stripping torque for the 3.5 mm (p < 0.01; R = 0.56) and 4.5 mm diameter stainless steel screws (p < 0.01; R = 0.57) at the femoral diaphysis. At the femoral metaphysis, femoral neck bone mineral density significantly correlated with the maximum screw stripping torque achieved by the 3.5 mm (p < 0.01; R = 0.61), 4.5 mm (p < 0.01; R = 0.51), and 6.5 mm diameter stainless steel screws (p < 0.01; R = 0.56). INTERPRETATION Reference Point Indentation can provide localized measurements of bone quality that may better inform surgeons of the competence of the bone-implant interface and improve effectiveness of fixation strategies particularly in patients with compromised bone quality.
Collapse
Affiliation(s)
| | - Avinesh Agarwalla
- Department of Biomedical Engineering, Washington University in St. Louis, MO, USA
| | - Adam C Abraham
- Department of Orthopaedic Surgery, Washington University in St. Louis, MO, USA
| | - Eric Feuchtbaum
- Department of Orthopaedic Surgery, Washington University in St. Louis, MO, USA
| | - William M Ricci
- Department of Orthopaedic Surgery, Washington University in St. Louis, MO, USA
| | - Simon Y Tang
- Department of Orthopaedic Surgery, Washington University in St. Louis, MO, USA; Department of Biomedical Engineering, Washington University in St. Louis, MO, USA; Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, MO, USA.
| |
Collapse
|
14
|
Locke RC, Abraham AC, Killian ML. Orthopedic Interface Repair Strategies Based on Native Structural and Mechanical Features of the Multiscale Enthesis. ACS Biomater Sci Eng 2016; 3:2633-2643. [PMID: 32832593 DOI: 10.1021/acsbiomaterials.6b00599] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The enthesis is an organ that connects a soft, aligned tissue (tendon/ligament) to a hard, amorphous tissue (bone) via a fibrocartilage interface. Mechanically, the enthesis sustains a dynamic loading environment that includes tensile, compressive, and shear forces. The structural components of the enthesis act to minimize stress concentrations and control stretch at the interface. Current surgical repair of the enthesis, such as in rotator cuff repair and anterior cruciate ligament reconstruction, aim to bridge the gap between the injured ends via reattachment of soft-to-hard tissues or graft replacement. In this review, we discuss the multiscale, morphological, and mechanical characteristics of the fibrocartilage attachment. Additionally, we review historical and recent clinical approaches to treating enthesis injury. Lastly, we explore new technological advancements in tissue-engineered biomaterials that have shown promise in preclinical studies.
Collapse
Affiliation(s)
- Ryan C Locke
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware 19716, United States
| | - Adam C Abraham
- Department of Orthopedic Surgery, Columbia University Medical Center, New York, New York 10032, United States
| | - Megan L Killian
- Department of Biomedical Engineering, University of Delaware, Newark, Delaware 19716, United States
| |
Collapse
|
15
|
Zhou L, Abraham AC, Tang SY, Chakrabartty S. A 5 nW Quasi-Linear CMOS Hot-Electron Injector for Self-Powered Monitoring of Biomechanical Strain Variations. IEEE Trans Biomed Circuits Syst 2016; 10:1143-1151. [PMID: 27214911 PMCID: PMC5315696 DOI: 10.1109/tbcas.2016.2523992] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Piezoelectricity-driven hot-electron injectors (p-HEI) are used for self-powered monitoring of mechanical activity in biomechanical implants and structures. Previously reported p-HEI devices operate by harvesting energy from a piezoelectric transducer to generate current and voltage references which are then used for initiating and controlling the process of hot-electron injection. As a result, the minimum energy required to activate the device is limited by the power requirements of the reference circuits. In this paper we present a p-HEI device that operates by directly exploiting the self-limiting capability of an energy transducer when driving the process of hot-electron injection in a pMOS floating-gate transistor. As a result, the p-HEI device can activate itself at input power levels less than 5 nW. Using a prototype fabricated in a 0.5- [Formula: see text] bulk CMOS process we validate the functionality of the proposed injector and show that for a fixed input power, its dynamics is quasi-linear with respect to time. The paper also presents measurement results using a cadaver phantom where the fabricated p-HEI device has been integrated with a piezoelectric transducer and is used for self-powered monitoring of mechanical activity.
Collapse
|
16
|
McKenzie JA, Buettmann E, Abraham AC, Gardner MJ, Silva MJ, Killian ML. Loss of scleraxis in mice leads to geometric and structural changes in cortical bone, as well as asymmetry in fracture healing. FASEB J 2016; 31:882-892. [PMID: 27864378 DOI: 10.1096/fj.201600969r] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2016] [Accepted: 11/07/2016] [Indexed: 01/08/2023]
Abstract
Scleraxis (Scx) is a known regulator of tendon development, and recent work has identified the role of Scx in bone modeling. However, the role of Scx in fracture healing has not yet been explored. This study was conducted to identify the role of Scx in cortical bone development and fracture healing. Scx green fluorescent protein-labeled (ScxGFP) reporter and Scx-knockout (Scx-mutant) mice were used to assess bone morphometry and the effects of fracture healing on Scx localization and gene expression, as well as callus healing response. Botulinum toxin (BTX) was used to investigate muscle unloading effects on callus shape. Scx-mutant long bones had structural and mechanical defects. Scx gene expression was elevated and bmp4 was decreased at 24 h after fracture. ScxGFP+ cells were localized throughout the healing callus after fracture. Scx-mutant mice demonstrated disrupted callus healing and asymmetry. Asymmetry of Scx-mutant callus was not due to muscle unloading. Wild-type littermates (age matched) served as controls. This is the first study to explore the role of Scx in cortical bone mechanics and fracture healing. Deletion of Scx during development led to altered long bone properties and callus healing. This study also demonstrated that Scx may play a role in the periosteal response during fracture healing.-McKenzie, J. A., Buettmann, E., Abraham, A. C., Gardner, M. J., Silva, M. J., Killian, M. L. Loss of scleraxis in mice leads to geometric and structural changes in cortical bone, as well as asymmetry in fracture healing.
Collapse
Affiliation(s)
- Jennifer A McKenzie
- Department of Orthopedic Surgery, Washington University School of Medicine, St. Louis, Missouri, USA
| | - Evan Buettmann
- Department of Orthopedic Surgery, Washington University School of Medicine, St. Louis, Missouri, USA
| | - Adam C Abraham
- Department of Orthopedic Surgery, Washington University School of Medicine, St. Louis, Missouri, USA
| | - Michael J Gardner
- Department of Orthopedic Surgery, Stanford University, Redwood City, California, USA; and
| | - Matthew J Silva
- Department of Orthopedic Surgery, Washington University School of Medicine, St. Louis, Missouri, USA
| | - Megan L Killian
- Department of Orthopedic Surgery, Washington University School of Medicine, St. Louis, Missouri, USA; .,Department of Biomedical Engineering, University of Delaware, Newark, Delaware, USA
| |
Collapse
|
17
|
Abraham AC, Liu JW, Tang SY. Longitudinal changes in the structure and inflammatory response of the intervertebral disc due to stab injury in a murine organ culture model. J Orthop Res 2016; 34:1431-8. [PMID: 27273204 PMCID: PMC5324835 DOI: 10.1002/jor.23325] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2016] [Accepted: 06/05/2016] [Indexed: 02/04/2023]
Abstract
Despite the significant public health impact of intervertebral disc (IVD) degeneration and low back pain, it remains challenging to investigate the multifactorial molecular mechanisms that drive the degenerative cascade. Organ culture model systems offer the advantage of allowing cells to live and interact with their native extracellular matrix, while simultaneously reducing the amount of biological variation and complexity present at the organismal level. Murine organ cultures in particular also allow the use of widely available genetically modified animals with molecular level reporters that would reveal insights on the degenerative cascade. Here, we utilize an organ culture system of murine lumbar functional spinal units where we are able to maintain the cellular, metabolic, and structural, and mechanical stability of the whole organ over a 21-day period. Furthermore, we describe a novel approach in organ culture by using tissues from animals with an NF-κB-luc reporter in combination with a mechanical injury model, and are able to show that proinflammatory factors and cytokines such as NF-κB and IL-6 produced by IVD cells can be monitored longitudinally during culture in a stab injury model. Taken together, we utilize a murine organ culture system that maintains the cellular and tissue level behavior of the intervertebral disc and apply it to transgenic animals that allow the monitoring of the inflammatory profile of IVDs. This approach could provide important insights on the molecular and metabolic mediators that regulate the homeostasis of the IVD. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:1431-1438, 2016.
Collapse
Affiliation(s)
- Adam C. Abraham
- Department of Orthopedic Surgery, Washington University in St. Louis, 660 S. Euclid, Campus Box 8233, St. Louis 63103, Missouri
| | - Jennifer W. Liu
- Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, Whitaker Hall, Campus Box 1097, St. Louis 63130, Missouri
| | - Simon Y. Tang
- Department of Orthopedic Surgery, Washington University in St. Louis, 660 S. Euclid, Campus Box 8233, St. Louis 63103, Missouri
- Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, Whitaker Hall, Campus Box 1097, St. Louis 63130, Missouri
- Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis, Missouri
| |
Collapse
|
18
|
Abraham AC, Agarwalla A, Yadavalli A, Liu JY, Tang SY. Microstructural and compositional contributions towards the mechanical behavior of aging human bone measured by cyclic and impact reference point indentation. Bone 2016; 87:37-43. [PMID: 27021150 PMCID: PMC4862905 DOI: 10.1016/j.bone.2016.03.013] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2015] [Revised: 03/23/2016] [Accepted: 03/24/2016] [Indexed: 02/05/2023]
Abstract
The assessment of fracture risk often relies primarily on measuring bone mineral density, thereby accounting for only a single pathology: the loss of bone mass. However, bone's ability to resist fracture is a result of its biphasic composition and hierarchical structure that imbue it with high strength and toughness. Reference point indentation (RPI) testing is designed to directly probe bone mechanical behavior at the microscale in situ, although it remains unclear which aspects of bone composition and structure influence the results at this scale. Therefore, our goal in this study was to investigate factors that contribute to bone mechanical behavior measured by cyclic reference point indentation, impact reference point indentation, and three-point bending. Twenty-eight female cadavers (ages 57-97) were subjected to cyclic and impact RPI in parallel at the unmodified tibia mid-diaphysis. After RPI, the middiaphyseal tibiae were removed, scanned using micro-CT to obtain cortical porosity (Ct.Po.) and tissue mineral density (TMD), then tested using three-point bending, and lastly assayed for the accumulation of advanced glycation end-products (AGEs). Both the indentation distance increase from cyclic RPI (IDI) and bone material strength index from impact RPI (BMSi) were significantly correlated with TMD (r=-0.390, p=0.006; r=0.430, p=0.002; respectively). Accumulation of AGEs was significantly correlated with IDI (r=0.281, p=0.046), creep indentation distance (CID, r=0.396, p=0.004), and BMSi (r=-0.613, p<0.001). There were no significant relationships between tissue TMD or AGEs accumulation with the quasi-static material properties. Toughness decreased with increasing tissue Ct.Po. (r=-0.621, p<0.001). Other three-point bending measures also correlated with tissue Ct.Po. including the bending modulus (r=-0.50, p<0.001) and ultimate stress (r=-0.56, p<0.001). The effects of Ct.Po. on indentation were less pronounced with IDI (r=0.290, p=0.043) and BMSi (r=-0.299, p=0.037) correlated modestly with tissue Ct.Po. These results suggest that RPI may be sensitive to bone quality changes relating to collagen.
Collapse
Affiliation(s)
- Adam C Abraham
- Department of Orthopedic Surgery, Washington University in St. Louis, 660 S. Euclid, Campus Box 8233, St. Louis, MO 63103, USA
| | - Avinesh Agarwalla
- Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, Whitaker Hall, Campus Box 1097, St. Louis, MO 63130, USA
| | - Aditya Yadavalli
- Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, Whitaker Hall, Campus Box 1097, St. Louis, MO 63130, USA
| | - Jenny Y Liu
- Department of Orthopedic Surgery, Washington University in St. Louis, 660 S. Euclid, Campus Box 8233, St. Louis, MO 63103, USA
| | - Simon Y Tang
- Department of Orthopedic Surgery, Washington University in St. Louis, 660 S. Euclid, Campus Box 8233, St. Louis, MO 63103, USA; Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, Whitaker Hall, Campus Box 1097, St. Louis, MO 63130, USA.
| |
Collapse
|
19
|
Abraham AC, Agarwalla A, Yadavalli A, McAndrew C, Liu JY, Tang SY. Multiscale Predictors of Femoral Neck In Situ Strength in Aging Women: Contributions of BMD, Cortical Porosity, Reference Point Indentation, and Nonenzymatic Glycation. J Bone Miner Res 2015; 30:2207-14. [PMID: 26060094 PMCID: PMC4673035 DOI: 10.1002/jbmr.2568] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2014] [Revised: 05/21/2015] [Accepted: 06/02/2015] [Indexed: 02/05/2023]
Abstract
The diagnosis of fracture risk relies almost solely on quantifying bone mass, yet bone strength is governed by factors at multiple scales including composition and structure that contribute to fracture resistance. Furthermore, aging and conditions such as diabetes mellitus alter fracture incidence independently of bone mass. Therefore, it is critical to incorporate other factors that contribute to bone strength in order to improve diagnostic specificity of fracture risk. We examined the correlation between femoral neck fracture strength in aging female cadavers and areal bone mineral density, along with other clinically accessible measures of bone quality including whole-bone cortical porosity (Ct.Po), bone material mechanical behavior measured by reference point indentation (RPI), and accumulation of advanced glycation end-products (AGEs). All measurements were found to be significant predictors of femoral neck fracture strength, with areal bone mineral density (aBMD) being the single strongest correlate (aBMD: r = 0.755, p < 0.001; Ct.Po: r = -0.500, p < 0.001; RPI: r = -0.478, p < 0.001; AGEs: r = -0.336, p = 0.016). RPI-derived measurements were not correlated with tissue mineral density or local cortical porosity as confirmed by micro-computed tomography (μCT). Multiple reverse stepwise regression revealed that the inclusion of aBMD and any other factor significantly improve the prediction of bone strength over univariate predictions. Combining bone assays at multiple scales such as aBMD with tibial Ct.Po (r = 0.835; p < 0.001), tibial difference in indentation depth between the first and 20th cycle (IDI) (r = 0.883; p < 0.001), or tibial AGEs (r = 0.822; p < 0.001) significantly improves the prediction of femoral neck strength over any factor alone, suggesting that this personalized approach could greatly enhance bone strength and fracture risk assessment with the potential to guide clinical management strategies for at-risk populations.
Collapse
Affiliation(s)
- Adam C Abraham
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Avinesh Agarwalla
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
| | - Aditya Yadavalli
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA
| | - Christopher McAndrew
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Jenny Y Liu
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA
| | - Simon Y Tang
- Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, MO, USA.,Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, USA.,Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis, MO, USA
| |
Collapse
|
20
|
Liu JW, Abraham AC, Tang SY. The high-throughput phenotyping of the viscoelastic behavior of whole mouse intervertebral discs using a novel method of dynamic mechanical testing. J Biomech 2015; 48:2189-94. [PMID: 26004435 DOI: 10.1016/j.jbiomech.2015.04.040] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2015] [Revised: 04/24/2015] [Accepted: 04/27/2015] [Indexed: 01/31/2023]
Abstract
Intervertebral disc (IVD) degeneration is highly correlated with lower back pain, and thus understanding the mechanisms of IVD degeneration is critical for the treatment of this disease. Utilizing mouse models to probe the mechanisms of degeneration is especially attractive due to the ease of manipulating mouse models and the availability of transgenics. Yet characterizing the mechanical behavior of mice IVDs remain challenging due to their minute size (approximately 540 μm in height and 1080 μm(2) in cross sectional area). We have thus developed a simple method to dynamically characterize the mechanical properties of intact mouse IVDs. The IVDs were dissected with the endplates intact, and dynamically compressed in the axial direction at 1% and 5% peak strains at 1 Hz. Utilizing this novel approach, we examined the effects of in vitro ribosylation and trypsin digestion for 24 or 72 h on the viscoelastic behavior of the whole murine IVD. Trypsin treatment resulted in a decrease of proteoglycans and loss of disc height, while ribosylation had no effect on structure or proteoglycan composition. The 72 h ribosylation group exhibited a stiffening of the disc, and both treatments significantly reduced viscous behavior of the IVDs, with the effects being more pronounced at 5% strain. Here we demonstrate a novel high-throughput method to mechanically characterize murine IVDs and detect strain-dependent differences in the elastic and the viscous behavior of the treated IVDs due to ribose and trypsin treatments.
Collapse
Affiliation(s)
- Jennifer W Liu
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, United States
| | - Adam C Abraham
- Department of Orthopaedic Surgery, Washington University in St. Louis, 660 South Euclid Avenue, Box 8233, St. Louis, MO 63110, United States
| | - Simon Y Tang
- Department of Biomedical Engineering, Washington University in St. Louis, St. Louis, MO, United States; Department of Orthopaedic Surgery, Washington University in St. Louis, 660 South Euclid Avenue, Box 8233, St. Louis, MO 63110, United States; Department of Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis, MO, United States.
| |
Collapse
|
21
|
Abraham AC, Villegas DF, Kaufman KR, Donahue TLH. Internal pressure of human meniscal root attachments during loading. J Orthop Res 2013; 31:1507-13. [PMID: 23775981 PMCID: PMC3902857 DOI: 10.1002/jor.22408] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2012] [Accepted: 05/14/2013] [Indexed: 02/04/2023]
Abstract
This study investigated the internal fluid pressure of human cadaver meniscal root attachments. A pressure micro-sensor was implanted inside each attachment site. Tibiofemoral joints were compressed to 2× body weight at various flexion angles and pressure recorded for 20 min. The anterior cruciate ligament (ACL) was then transected and joints retested. Lastly, a longitudinal incision of the lateral posterior (LP) horn was made and the joint retested. Ramp pressure was defined as the pressure when 2× body weight was reached, and equilibrium pressure was recorded at the end of the hold period. The medial posterior (MP) attachment was subjected to greater ramp pressure than the medial anterior (p = 0.002) and greater equilibrium pressure than all other root attachment sites (p < 0.001). Flexion angle had a significant effect on pressure as full extension was greatest at ramp (p = 0.040). Transection of the ACL decreased ramp pressure in the LP attachment (p = 0.025) and increased equilibrium pressure (p = 0.031) in the MP attachment. The results suggest that repair strategies should be developed which reconstruct the MP attachments to be sufficient to withstand large pressures. Furthermore, since meniscal pressure is highest at full extension, this fact should be considered when prescribing rehabilitation following repair of an attachment.
Collapse
Affiliation(s)
- Adam C. Abraham
- Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80523
| | - Diego F. Villegas
- Department of Mechanical Engineering, Universidad del Turabo, Gurabo, Puerto Rico 00778
| | - Kenton R. Kaufman
- Biomechanics and Motion Analysis Lab, Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota 59905
| | - Tammy L. Haut Donahue
- Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80523
| |
Collapse
|
22
|
Abraham AC, Donahue TLH. From meniscus to bone: a quantitative evaluation of structure and function of the human meniscal attachments. Acta Biomater 2013; 9:6322-9. [PMID: 23385217 DOI: 10.1016/j.actbio.2013.01.031] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2012] [Revised: 01/16/2013] [Accepted: 01/28/2013] [Indexed: 12/01/2022]
Abstract
Meniscus efficacy at promoting joint congruity and preventing osteoarthritis hinges on enthesis integrity. Gross-scale tensile testing, histomorphometry and magnetic resonance imaging reveal significant differences between the four attachments, implying that each must endure a unique mechanical environment, which dictates their structure. However, little data exists to elucidate how these interfaces have adapted to their complex loading environment, particularly on a relevant scale, as the enthesis transitions through several unique zones in less than a millimeter. In our study we leveraged nanoindentation to determine viscoelastic material properties through the transition zones. Additionally, we employed histological techniques to evaluate the enthesis structure, including collagen organization and interdigitation morphometry. Mechanical evaluation revealed the medial posterior insertion site to be significantly more compliant than others. Collagen fiber orientation and dispersion as well as interdigitation morphometry were significantly different between attachments sites. These findings are clinically relevant as a disproportionate amount of enthesis failure occurs in the medial posterior attachment. Also, meniscal enthesis structure and function will need to be considered in future reparative and replacement strategies in order to recreate native meniscus mechanics and prevent osteoarthritis propagation.
Collapse
Affiliation(s)
- Adam C Abraham
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | | |
Collapse
|
23
|
Moyer JT, Priest R, Bouman T, Abraham AC, Haut Donahue TL. Indentation properties and glycosaminoglycan content of human menisci in the deep zone. Acta Biomater 2013; 9:6624-9. [PMID: 23321302 DOI: 10.1016/j.actbio.2012.12.033] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2012] [Revised: 12/10/2012] [Accepted: 12/27/2012] [Indexed: 02/07/2023]
Abstract
Menisci are two crescent shaped fibrocartilaginous structures that provide fundamental load distribution and support within the knee joint. Their unique shape transmits axial stresses (i.e. "body force") into hoop or radial stresses. The menisci are primarily an inhomogeneous aggregate of glycosaminoglycans (GAGs) supporting bulk compression and type I collagen fibrils sustaining tension. It has been shown that the superficial meniscal layers are functionally homogeneous throughout the three distinct regions (anterior, central and posterior) using a 300 μm diameter spherical indenter tip, but the deep zone of the meniscus has yet to be mechanically characterized at this scale. Furthermore, the distribution and content of GAG throughout the human meniscal cross-section have not been examined. This study investigated the mechanical properties, via indentation, of the human deep zone meniscus among three regions of the lateral and medial menisci. The distribution of GAGs through the cross-section was also documented. Results for the deep zone of the meniscus showed the medial posterior region to have a significantly greater instantaneous elastic modulus than the central region. No significant differences in the equilibrium modulus were seen when comparing regions or the hemijoint. Histological results revealed that GAGs are not present until at least ~600 μm from the meniscal surface. Understanding the role and distribution of GAG within the human meniscus in conjunction with the material properties of the meniscus will aid in the design of tissue engineered meniscal replacements.
Collapse
|
24
|
Abraham AC, Kaufman KR, Donahue TLH. Phenomenological consequences of sectioning and bathing on passive muscle mechanics of the New Zealand white rabbit tibialis anterior. J Mech Behav Biomed Mater 2013; 17:290-5. [PMID: 23127626 PMCID: PMC3513661 DOI: 10.1016/j.jmbbm.2012.10.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2012] [Revised: 09/26/2012] [Accepted: 10/01/2012] [Indexed: 10/27/2022]
Abstract
Skeletal muscle tissue provides support and mobility of the musculoskeletal system. Numerical modeling of muscle tissue aids in understanding disease pathophysiology, however, the effectiveness is dependent on accurately accounting for various tissue phenomena. Muscle modeling is made difficult due to the multitude of constituents that contribute to elastic and viscous mechanisms. Often, deterministic single fiber or fiber bundle studies are undertaken to examine these contributions. However, examination of whole, intact and structurally altered tissue and comparison to findings at the myofibril scale can help elucidate tissue mechanics. Stress relaxation tests at 10% strain were performed on 28 New Zealand White rabbit's tibialis anterior muscles for whole, intact muscle and sub-sectioned muscle samples. Additionally, to aid in examining viscous effects, sub groups were tested with and without a phosphate buffered saline bath. The steady-state elastic modulus was not significantly different between groups. Interestingly, sectioning did result in a negative Poisson's ratio following tensile loading. Additionally, sectioning resulted in altering the viscous tissue response as the time to reach steady-state was significantly faster than whole muscle samples (p<0.05), as well as the linear relaxation rate from 0 to 0.1 (p<0.01), 1 to 10 (p<0.05), and 10 to 100 s (p<0.05). Bathing tissue resulted in a significantly greater amount of percent stress relaxation for whole muscle (p<0.01). These findings provide new insight into the differing mechanical characteristics of whole and sectioned muscle tissue.
Collapse
Affiliation(s)
- Adam C Abraham
- Soft Tissue Mechanics Laboratory, Department of Mechanical Engineering, Colorado State University, Fort Collins, CO 80523, USA
| | | | | |
Collapse
|
25
|
Moyer JT, Abraham AC, Haut Donahue TL. Nanoindentation of human meniscal surfaces. J Biomech 2012; 45:2230-5. [PMID: 22789734 DOI: 10.1016/j.jbiomech.2012.06.017] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2012] [Revised: 06/09/2012] [Accepted: 06/12/2012] [Indexed: 10/28/2022]
Abstract
Menisci are crescent shaped fibrocartilaginous structures which support load distribution of the knee. The menisci are specifically designed to fit the contour of the femoral condyles, aiding to disperse the stresses on the tibial plateau and in turn safeguarding the underlying articular cartilage. The importance of the meniscal superficial layer has not been fully revealed and it is suspected that this layer plays a pivotal role for meniscal function. In this study, both femoral (proximal) and tibial (distal) contacting meniscal surfaces were mechanically examined on the nano-level among three distinct regions (anterior, central and posterior) of the lateral and medial menisci. Nanoindentation testing showed no significant differences among regions, surfaces or anatomical locations, possibly elucidating on the homogeneity of the meniscal superficial zone structure (E(instantaneous): 3.17-4.12MPa, E(steady-state): 1.47-1.69MPa). Nanomechanical moduli values were approximately an order of magnitude greater than micro-scale testing derived moduli values. These findings validate the structural homogeneity of the meniscal superficial zone, showing that material properties are statistically similar regardless of meniscal surface and region. Understanding the mechanical behavior of meniscal surfaces is imperative to properly design an effective meniscal replacement.
Collapse
Affiliation(s)
- John T Moyer
- Department of Mechanical Engineering-Engineering Mechanics, Michigan Technological University, Houghton, MI 49931, USA
| | | | | |
Collapse
|
26
|
Abraham AC, Edwards CR, Odegard GM, Donahue TLH. Regional and fiber orientation dependent shear properties and anisotropy of bovine meniscus. J Mech Behav Biomed Mater 2011; 4:2024-30. [PMID: 22098902 DOI: 10.1016/j.jmbbm.2011.06.022] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2011] [Revised: 06/16/2011] [Accepted: 06/21/2011] [Indexed: 12/13/2022]
Abstract
Imaging of meniscal tissue reveals an extracellular matrix comprised of collagen fibrils arranged in circumferential bundles and radially aligned tie fibers, implicating structural material anisotropy. Biochemical analyses demonstrate regional disparities of proteoglycan content throughout the meniscal body, a constituent known to affect the shearing response of fibrocartilagenous tissue. Despite this phenomenological evidence and previous mechanical testing implicating otherwise, the meniscus if often modeled as a homogeneous, transversely isotropic material with little regard for regional specificity and material properties. The aim of this investigation was to determine if shear stress response homogeneity and directionality exists in and between bovine menisci with respect to anatomical location (medial and lateral), region (anterior, central, and posterior) and fiber orientation (parallel and perpendicular). Meniscus explants were subjected to lap shear strain at 0.002 s(-1) with the circumferential collagen fibers oriented parallel or perpendicular to the loading axis. Comparisons were made using a piecewise linear elastic analysis. The toe region shear modulus was calculated from the first observed linear region, between 3% and 13% strain and the extended shear modulus was established after 80% of the maximum shear strain. The posterior region was significantly different than the central for the extended shear modulus, correlating with known proteoglycan distribution. Observed shearing anisotropy led to the use of an anisotropic hyperelastic model based on a two-fiber family composite, previously used for arterial walls. The chosen model provided an excellent fit to the sample population for each region. These data can be utilized in the advancement of finite element modeling as well as biomimetic tissue engineered constructs.
Collapse
Affiliation(s)
- Adam C Abraham
- Department of Mechanical Engineering-Engineering Mechanics, Michigan Technological University, Houghton, MI, 49931, United States
| | | | | | | |
Collapse
|
27
|
Abraham AC, Moyer JT, Villegas DF, Odegard GM, Haut Donahue TL. Hyperelastic properties of human meniscal attachments. J Biomech 2010; 44:413-8. [PMID: 20980006 DOI: 10.1016/j.jbiomech.2010.10.001] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2010] [Revised: 10/01/2010] [Accepted: 10/06/2010] [Indexed: 11/29/2022]
Abstract
Meniscal attachments are ligamentous tissues anchoring the menisci to the underlying subchondral bone. Currently little is known about the behavior of meniscal attachments, with only a few studies quantitatively documenting their properties. The objective of this study was to quantify and compare the tensile mechanical properties of human meniscal attachments in the transverse direction, curve fit experimental Cauchy stress-stretch data to evaluate the hyperelastic behavior, and couple these results with previously obtained longitudinal data to generate a more complete constitutive model. Meniscal attachment specimens were tested using a uniaxial tension test with the collagen fibers oriented perpendicular to the loading axis. Tests were run until failure and load-optical displacement data was recorded for each test. The medial posterior attachment was shown to have a significantly greater elastic modulus (6.42±0.78 MPa) and ultimate stress (1.73±0.32 MPa) when compared to the other three attachments. The Mooney-Rivlin material model was selected as the best fit for the transverse data and used in conjunction with the longitudinal data. A novel computational approach to determining the transition point between the toe and linear regions is presented for the hyperelastic stress-stretch curves. Results from piece-wise non-linear longitudinal curve fitting correlate well with previous linear elastic and SEM findings. These data can be used to advance the design of meniscal replacements and improve knee joint finite element models.
Collapse
Affiliation(s)
- Adam C Abraham
- Department of Mechanical Engineering-Engineering Mechanics, Michigan Technological University, 815 R.L. Smith Building, Houghton, MI 49931, USA
| | | | | | | | | |
Collapse
|