1
|
Deste Gökay G, Oyar P, Durkan R. Impact of various aging treatments on the microhardness and surface roughness of CAD-CAM monolithic restorative materials. J Prosthodont 2024. [PMID: 38638109 DOI: 10.1111/jopr.13846] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Accepted: 03/05/2024] [Indexed: 04/20/2024] Open
Abstract
PURPOSE Dental ceramics deteriorate as a result of thermal aging and exposure to acidic solutions, which change their microhardness and surface roughness. This study assessed the resistance of several computer-aided design and computer-aided manufacturing (CAD-CAM) restorative dental materials in terms of surface roughness and microhardness following exposure to acidic solutions and thermal aging. MATERIALS AND METHODS Five different monolithic CAD-CAM restorative materials, two leucite-reinforced glass ceramics (G-Ceram and CEREC Blocs), a zirconia-infiltrated lithium silicate (Celtra Duo), a resin nanoceramic (Grandio), and monolithic zirconia (inCoris TZI), were used to create 2-mm-thick rectangular specimens (n = 100). After being immersed in either acidic saliva (pH = 4.0) (ST) or gastric juice (pH = 1.2) (GT), each material was subjected to 10,000 cycles of thermal aging. The Vickers microhardness and average surface roughness of the specimens were assessed at baseline, following thermal aging and exposure to either gastric juice or acidic saliva. The surface properties were examined using an atomic force microscope. The Mann‒Whitney U test with Bonferroni correction and the Wilcoxon signed-rank test was used for statistical analysis (a = 0.05). RESULTS The surface roughness of two leucite-reinforced glass ceramics (G-ceram and CEREC) significantly decreased with ST (p = 0.027 and p = 0.044). Only the CEREC was affected when the aging protocols were compared, and the ST group had a significant reduction in roughness (p = 0.009). The microhardness values significantly decreased after both aging protocols in all groups except for the ST subgroup of G-Ceram. Only inCoris was affected when the aging protocols were compared, and the GT group exhibited a significant reduction in microhardness (p = 0.002). CONCLUSION The surface roughness of the tested materials was not affected by the GT. Only leucite ceramics exhibited a decrease in surface roughness in the ST stage. Both aging processes produced a significant decrease in the microhardness of the tested ceramics. Leucite-reinforced glass-ceramic materials may be advantageous for patients with gastroesophageal reflux disease and those with a diet high in acidic foods due to their lower values for changes in microhardness and surface roughness compared to those of other CAD-CAM materials.
Collapse
Affiliation(s)
- Gonca Deste Gökay
- Faculty of Dentistry, Department of Prosthodontics, Bursa Uludağ University, Bursa, Türkiye
| | - Perihan Oyar
- Dental Prosthetics Technology, School of Health Services, Hacettepe University, Ankara, Türkiye
| | - Rukiye Durkan
- Faculty of Dentistry, Department of Prosthodontics, Istanbul Okan University, Istanbul, Türkiye
| |
Collapse
|
2
|
Gökay GD, Aladağ SÜ. Comparison of the shear bond strengths of two different polyetheretherketone (PEEK) framework materials and CAD-CAM veneer materials. BMC Oral Health 2024; 24:444. [PMID: 38609958 PMCID: PMC11010332 DOI: 10.1186/s12903-024-04247-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Accepted: 04/10/2024] [Indexed: 04/14/2024] Open
Abstract
BACKGROUND This study evaluated the shear bond strength (SBS) of two different polyetheretherketone (PEEK) and CAD-CAM materials after aging. METHODS A total of 42 frameworks were designed and milled from 2 different PEEK discs (Copra Peek, P and BioHPP, B). P and B frameworks were divided into 3 subgroups (n = 7). 14 slices were prepared each from feldspathic ceramic (Vitablocs Mark II, VM), hybrid nanoceramic (Cerasmart, CS), and polymer-infiltrated ceramic (Vita Enamic, VE) blocks. After surface preparations, the slices were cemented to P and B surfaces. The samples were subjected to thermal aging (5000 cycles). SBS of all the samples was measured. Fractured surfaces were examined by SEM/EDX analysis. The Shapiro-Wilk, Two-way Robust ANOVA and Bonferroni correction tests were used to analyze the data (a = .05). RESULTS Frameworks, ceramics, and frameworks x ceramics had significant differences (p < 0.05). The highest SBS value was seen in B-VM (p < 0.05). VM offered the highest SBS with both P and B. The differences between P-VM, P-CS, P-VE and B-CS and B-VE were insignificant (p > 0.05). According to EDX analysis, ytterbium and fluorine was seen in B content, unlike P. While VM and CS contained fluorine, barium, and aluminum; sodium and aluminum were observed in the VE structure. CONCLUSION Bonding of P and B with VM offers higher SBS. VM, CS and VE did not make any difference in SBS for P, however VM showed a significant difference for B.
Collapse
Affiliation(s)
- Gonca Deste Gökay
- Department of Prosthodontics, Faculty of Dentistry, Bursa Uludağ University, Bursa, Turkey
| | - Seda Üstün Aladağ
- Department of Prosthodontics, Faculty of Dentistry, Bursa Uludağ University, Bursa, Turkey.
| |
Collapse
|
3
|
Gökay GD, Görürgöz C, Kılınç A. Effect of morality or capitalist ideology in choosing dentistry as a career in Türkiye: a cross sectional study. BMC Med Educ 2024; 24:274. [PMID: 38481265 PMCID: PMC10935895 DOI: 10.1186/s12909-024-05275-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2023] [Accepted: 03/07/2024] [Indexed: 03/17/2024]
Abstract
BACKGROUND Previous studies have provided important findings on the profession of dentistry and the motivators for choosing dentistry. This study has attempted to contribute to this accumulation by using a sociocultural perspective and interpreting the relationships among motivators from this perspective in a large Turkish sample. The aim of this study was to investigate what motivates dental students to choose dentistry as a career in Türkiye. METHODS First-year dental students from different dental schools were included in a descriptive cross-sectional study. The questionnaire included sections covering demographics, motivators and career satisfaction. A total of 919 students from 29 different state dental schools and four private dental schools participated. Descriptive statistics such as percentages, means and standard deviations were used to summarize the sociodemographic information and the distribution of the motivators. Factorial analysis was carried out for the structural status of the questionnaire items. The relationships between the motivators were analyzed using Pearson's correlation. RESULTS Among the 919 students, 64.2% were female, and 35.8% were male. Half of them chose dentistry after seeing their higher education institution's examination results, while the other half had already considered it a career during their preuniversity years. Communicating with people, artistic skills, and helping others were the main motivators for students to choose dentistry as a career in Türkiye, and students' overall career satisfaction was moderately high. The strongest correlations were between communication with people and benefits (r =.74), between communication with people and helping others (r =.71), between communication with people and artistic skills (r =.66), between artistic skills and benefits (r =.69), between artistic skills and helping others (r =.65), between dental experience and benefits (r =.51), between dental experience and helping others (r =.50), and between benefits and helping others (r =.71). CONCLUSION Helping others, artistic skills, communicating with people, and benefits were the most important factors motivating dental students to choose a career, and positive relationships were detected between these four factors. This information may help to develop more effective career guidance and mentorship strategies for dental students.
Collapse
Affiliation(s)
- Gonca Deste Gökay
- Department of Prosthodontics, Faculty of Dentistry, Bursa Uludag University, Bursa, Türkiye.
| | - Cansu Görürgöz
- Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Bursa Uludag University, Bursa, Türkiye
| | - Ahmet Kılınç
- Department of Science Education, Faculty of Education, Bursa Uludag University, Bursa, Türkiye
| |
Collapse
|
4
|
Gökçimen G, Durkan R, Deste Gökay G, Oyar P. The effect of different abutment and restorative crown materials on stress distribution in single-unit implant-supported restoration: A 3D finite element stress analysis. J Prosthodont 2023. [PMID: 37434476 DOI: 10.1111/jopr.13732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2022] [Revised: 06/21/2023] [Accepted: 06/25/2023] [Indexed: 07/13/2023] Open
Abstract
PURPOSE To evaluate the effect of restorative materials with or without resin content, modeled on zirconia and titanium abutment materials, on the stress distribution on the alveolar bone, implant, and prosthetic crowns with a 3D finite element stress analysis. MATERIAL AND METHODS Titanium and zirconia abutments were combined with three implant-supported crown materials (polymer infiltrated hybrid ceramic (PICN), lithium disilicate (LD), and zirconia-reinforced lithium silicate (ZLS)) to create six experimental groups. The 40×30×20 mm alveolar bone, 3.75×10 mm implant, esthetic abutment, and maxillary first premolar crown bonded over the abutment were the components of the finite element models. On the lingual cusp of the crown, the 150 N occlusal loading was applied in the buccolingual direction at a 30° angle. Equivalent von Mises stress and maximum and minimum principal stresses were used for both the qualitative and quantitative evaluation of the stress distribution of the created models. RESULTS The von Mises stress in implant and abutment did not differ according to the crown materials. The use of a zirconia abutment resulted in higher von Mises stress values in the abutment but lower stress values in the implant. The highest stress values were obtained in ZLS (196.65 MPa) and LD (194.05 MPa) crowns. The use of titanium abutments, regardless of crown materials, resulted in higher von Mises stress values in restorative crowns than in zirconia abutments. The principal stress values in alveolar bone showed similar distribution and concentration in all models. CONCLUSIONS Changes in crown material did not affect stress distribution in the implant and peripheral bone. However, the zirconia esthetic abutment resulted in a lower stress concentration on the implant. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Gülsüm Gökçimen
- Department of Prosthodontics, Ankara 75th year Oral and Dental Health Hospital, Ankara, Turkiye
| | - Rukiye Durkan
- Department of Prosthodontics, Faculty of Dentistry, Istanbul Okan University, Istanbul, Turkiye
| | - Gonca Deste Gökay
- Department of Prosthodontics, Faculty of Dentistry, Bursa Uludağ University, Bursa, Turkiye
| | - Perihan Oyar
- Dental Prosthetics Technology, School of Health Services, Hacettepe University, Ankara, Turkiye
| |
Collapse
|
5
|
Güçlü ZB, Gürbüz A, Deste Gökay G, Durkan R, Oyar P. Mechanical response of different frameworks for maxillary all-on-four implant-supported fixed dental prosthesis: 3D finite element analysis. BIOMED ENG-BIOMED TE 2022; 67:419-428. [PMID: 35972416 DOI: 10.1515/bmt-2022-0176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 08/02/2022] [Indexed: 11/15/2022]
Abstract
This study's purpose is to assess the stress distribution in the peri-implant bone, implants, and prosthetic framework using two different posterior implant angles. All-on-four maxillary prostheses fabricated from feldspathic-ceramic-veneered zirconia-reinforced lithium silicate (ZLS) and feldspathic-ceramic-veneered cobalt-chromium (CoCr) were designed with 17 or 30-degree-angled posterior implants. Posterior cantilever and frontal vertical loads were applied to all models. The distribution of maximum and minimum principal stresses (σmax and σmin) and von Mises stress (σVM) was evaluated. Under posterior cantilever load, with an increase in posterior implant angle, σmax decreased by 4 and 7 MPa in the cortical bone when ZLS and CoCr were used as a prosthetic framework, respectively. Regardless of the framework material, 17-degree-angled posterior implants showed the highest σVM (541.36 MPa under posterior cantilever load; 110.79 MPa under frontal vertical load) values. Regardless of the posterior implant angle, ZLS framework showed the highest σVM (91.59 MPa under posterior cantilever load; 218.99 MPa under frontal vertical load) values. Increasing implant angle from 17 to 30° caused a decrease in σmax values in the cortical bone. Designs with 30-degree posterior implant angles and ZLS framework material may be preferred in All-on-four implant-supported fixed complete dentures.
Collapse
Affiliation(s)
- Zekiye Begüm Güçlü
- Faculty of Dentistry, Department of Prosthodontics, Ankara University, Ankara, Turkey
| | - Ayhan Gürbüz
- Faculty of Dentistry, Department of Prosthodontics, Ankara University, Ankara, Turkey
| | - Gonca Deste Gökay
- Faculty of Dentistry, Department of Prosthodontics, Bursa Uludağ University, Bursa, Turkey
| | - Rukiye Durkan
- Faculty of Dentistry, Department of Prosthodontics, Istanbul Okan University, Istanbul, Turkey
| | - Perihan Oyar
- Dental Prosthetics Technology, Vocational School of Health Services, Hacettepe University, Ankara, Turkey
| |
Collapse
|
6
|
Gürbüz A, Güçlü ZB, Deste Gökay G, Durkan R. Biomechanical comparison of different prosthetic materials and posterior implant angles in all-on-4 treatment concept by three-dimensional finite element analysis. BIOMED ENG-BIOMED TE 2022; 67:307-315. [PMID: 35587648 DOI: 10.1515/bmt-2022-0109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Accepted: 04/21/2022] [Indexed: 11/15/2022]
Abstract
The study aimed to evaluate the biomechanical behaviors of different prosthetic materials and posterior implant angles in All-on-4 implant-supported fixed maxillary prostheses with three-dimensional (3D) finite element analysis. The model of complete edentulous maxilla was created using the Rhinoceros and VRMesh Studio programs. Anterior vertical and 17°- and 30°-angled posterior implants were positioned with All-on-4 design. Straigth and angled multi-unit abutments scanned using a 3D scanner. Two different prosthetic superstructures (monolithic zirconia framework and lithium disilicate veneer (ZL) and monolithic zirconia-reinforced lithium silicate (ZLS)) were modeled. Four models designed according to the prosthetic structure and posterior implant angles. Posterior vertical bilateral loading and frontal oblique loading was performed. The principal stresses (bone tissues-Pmax and Pmin) and von Mises equivalent stresses (implant and prosthetic structures) were analyzed. In all models, the highest Pmax stress values were calculated under posterior bilateral loading in cortical bone. The highest von Mises stress levels occured in the posterior implants under posterior bilateral load (260.33 and 219.50 MPa) in the ZL-17 and ZL-30 models, respectively. Under both loads, higher stress levels in prosthetic structures were shown in the ZLS models compared with ZL models. There was no difference between posterior implant angles on stress distribution occurred in implant material and alveolar bone tissue. ZLS and ZL prosthetic structures can be reliably used in maxillary All-on-4 rehabilitation.
Collapse
Affiliation(s)
- Ayhan Gürbüz
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Zekiye Begüm Güçlü
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Gonca Deste Gökay
- Department of Prosthodontics, Faculty of Dentistry, Bursa Uludağ University, Bursa, Turkey
| | - Rukiye Durkan
- Department of Prosthodontics, Faculty of Dentistry, Istanbul Okan University, Istanbul, Turkey
| |
Collapse
|
7
|
Ekici Ö, Dündar Ü, Gökay GD, Büyükbosna M. Evaluation of the efficiency of different treatment modalities in individuals with painful temporomandibular joint disc displacement with reduction: a randomised controlled clinical trial. Br J Oral Maxillofac Surg 2021; 60:350-356. [PMID: 34756640 DOI: 10.1016/j.bjoms.2021.08.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Accepted: 08/19/2021] [Indexed: 11/29/2022]
Abstract
The aim of the study was to investigate and compare short and long-term effects of occlusal splints (OS), ultrasound (US), and high-intensity laser therapy (HILT) in patients with painful temporomandibular joint (TMJ) disc displacement with reduction (DDWR). This prospective, randomised, single-blinded, controlled clinical study was conducted on patients with DDWR at a university oral and maxillofacial surgery clinic. A total of 140 patients were allocated randomly to four groups (OS, US, HILT, and control), with 35 patients in each. Patients were evaluated for pain, range of motion of the jaw, disability, and quality of life. A total of 132 patients completed the study. In all treatment groups (OS, US, and HILT), a significant improvement was observed in terms of pain, function, disability, and quality of life, at both weeks four and 12 compared with the control group (p < 0.001). Improvements in VAS pain and maximum mouth opening were not significantly different between the treatment groups. However, compared with the OS group, there was a significant improvement in the HILT and US groups in terms of total Oral Health Impact Profile (OHIP-14) and Jaw Functional Limitation Scale-20 (JFLS-20) scores at week four, but no difference between the groups at week 12. The results of this study show that OS, US, and HILT are effective treatments for pain and functional jaw movements in patients with DDWR. HILT, a new method, can be an alternative treatment in cases of TMD.
Collapse
Affiliation(s)
- Ömer Ekici
- Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey.
| | - Ümit Dündar
- Department of Physical Medicine and Rehabilitation, Faculty of Medicine, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey
| | - Gonca Deste Gökay
- Department of Prosthetic Dentistry, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey
| | - Murat Büyükbosna
- Department of Physical Medicine and Rehabilitation, Faculty of Medicine, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey
| |
Collapse
|
8
|
Durkan R, Deste Gökay G, Şimşek H, Yilmaz B. Biaxial flexural strength and phase transformation characteristics of dental monolithic zirconia ceramics with different sintering durations: An in vitro study. J Prosthet Dent 2021; 128:498-504. [PMID: 34059297 DOI: 10.1016/j.prosdent.2021.04.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 04/02/2021] [Accepted: 04/02/2021] [Indexed: 11/29/2022]
Abstract
STATEMENT OF PROBLEM Zirconia is a polymorphic metastable material which can react through a phase transformation from tetragonal to monoclinic when exposed to mechanical, physical, or chemical stimuli. PURPOSE The purpose of this in vitro study was to investigate the fracture strength and phase structure of different high-translucency zirconia ceramics depending on the changes in sintering duration and thermocycling. MATERIAL AND METHODS Two monolithic zirconia ceramics, Katana (KAT) and NexxZr (NEX), were used to prepare disk-shaped specimens (n=66). The sintering temperature was 1500 °C, and 3 different sintering durations were tested: 1 hour, 2 hours (recommended by the manufacturer), and 3 hours. Thermocycling was applied to half the specimens. Fracture strength was calculated, and the specimens were analyzed with an X-ray diffractometer (XRD) to determine the level of the phase transformation. The normal distribution of the data was analyzed by using the Shapiro-Wilk test. Two-way ANOVA was used to compare multiple groups (α=.05). The Fisher least significant difference test was applied to identify significant differences in fracture strength. The paired-specimen t test was applied to perform intragroup comparisons. RESULTS Sintering duration significantly affected the fracture strength of KAT (P=.007). For nonthermocycled specimens, the fracture strength of NEX was significantly higher than that of KAT (P<.001). Thermocycling had a significant effect on fracture strength depending on sintering duration and zirconia ceramic interaction (P=.046). CONCLUSIONS The sintering duration only affected the KAT zirconia, and the fracture strength of KAT decreased when sintered for 3 hours. Thermocycling decreased the fracture strength of both zirconias, except when the sintering duration was 2 hours for NEX. The fracture strength was higher for NEX than for KAT. Tetragonal-monoclinic phase transformation was not found for either zirconia according to the XRD analysis.
Collapse
Affiliation(s)
- Rukiye Durkan
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey
| | - Gonca Deste Gökay
- Asisstant Professor, Department of Prosthodontics, Faculty of Dentistry, Bursa Uludağ University, Bursa, Turkey.
| | | | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio
| |
Collapse
|
9
|
Durkan R, Şimşek H, Deste Gökay G, Yilmaz B. Effects of sintering time on translucency and color of translucent zirconia ceramics. J ESTHET RESTOR DENT 2021; 33:654-659. [PMID: 33638578 DOI: 10.1111/jerd.12723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Revised: 02/05/2021] [Accepted: 02/18/2021] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To investigate the effect of sintering time on translucency and color of translucent zirconia ceramics. MATERIALS AND METHODS Sixty translucent zirconia (5Y-TZP) specimens (12 × 1.6 mm, Katana (KAT) and NexxZr (NEX)) were divided into six groups (n = 10) according to sintering time; 1, 2 (specified by manufacturer-control), and 3 hs. Color differences (ΔEab) within same material when sintered using different times and between materials when same sintering time was used were calculated, as well as translucency parameters (TP) after the use of each sintering time. Data for ΔEab and TP were analyzed with two-way ANOVAs, pairwise comparisons, and Fisher's LSD Test (Post-hoc). RESULTS When 1 or 3 h were used, color difference from the color of specimens when manufacturer-specified time (2 h) was used was similar for both KAT and NEX. ΔEab values of NEX were significantly higher than KAT when sintered for 1 or 3 h (P < 0.001). TP increased for KAT when sintered for 1 h, and was higher than NEX. TP for NEX increased when sintered for 3 h (P < 0.001), but was not significantly different than that of KAT. CONCLUSIONS Effect of 1 or 3-h sintering on color was similar for both zirconias. For NEX, this effect resulted in greater differences from the color of specimens when manufacturer-specified time was used. Sintering for 1 h increased the translucency of KAT. CLINICAL SIGNIFICANCE When high translucency is desired, clinicians may prefer 1-h sintering for KAT zirconia. When lower translucency is desired, 3-h sintering for NEX can be used. However, for NEX, the color after 1- or 3-h sintering was different than the color obtained with manufacturer-specified time, and this difference may affect the final color of restoration compared to the final color when manufacturer-specified time is used.
Collapse
Affiliation(s)
- Rukiye Durkan
- Faculty of Dentistry, Department of Prosthodontics, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey
| | | | - Gonca Deste Gökay
- Faculty of Dentistry, Department of Prosthodontics, Bursa Uludağ University, Bursa, Turkey
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.,Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland.,Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio, USA
| |
Collapse
|
10
|
Deste Gökay G, Özkan P, Durkan R, Oyar P. Measurements of surface scale changes in different denture base materials by stereophotogrammetric technique. J Dent Res Dent Clin Dent Prospects 2021; 15:1-6. [PMID: 33927833 PMCID: PMC8058156 DOI: 10.34172/joddd.2021.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Accepted: 12/09/2020] [Indexed: 11/09/2022] Open
Abstract
Background. This study aimed to evaluate the surface scale changes in the denture base material using different polymerization techniques, such as heat-cure/pressure polymerization system and injection molding technique with the stereophotogrammetric technique. The function of a complete denture is related to the adaptation of its base to the supporting areas. Proper adaptation of the base depends on the stability and retention of dentures. The surface scale changes of dentures during processing and in service are of great importance since they affect the denture base material's fit. Methods. This study focused on the use of a computer-assisted stereophotogrammetric method for measuring changes in the volume of three different denture base resins of an edentulous maxillary ridge. A stone master model simulating the shape of an edentulous maxillary arch was used to prepare three groups of denture base resins. The stereophotographs were evaluated to determine the surface scale differences of maxillary jaws. Results. The results showed no significant differences between the denture borders for three denture base materials (P > 0.05). Conclusion. In the evaluation made using this technique, no significant difference was found in the different polymerization techniques in terms of surface scale changes for three denture base materials. Stereophotogrammetry, especially the digital stereophotogrammetric technique, has several useful research applications in prosthodontics.
Collapse
Affiliation(s)
- Gonca Deste Gökay
- Department of Prosthodontics, Faculty of Dentistry, Bursa Uludağ University, Bursa, Turkey
| | - Pelin Özkan
- Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara, Turkey
| | - Rukiye Durkan
- Department of Prosthodontics, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Afyonkarahisar, Turkey
| | - Perihan Oyar
- Department of Dental Prostheses Technology, Health Services Vocational High School, Hacettepe University, Ankara, Turkey
| |
Collapse
|