1
|
Mancinelli-Lyle D, Qaqish JG, Goyal CR, Schuller R. Efficacy of water flossing on clinical parameters of inflammation and plaque: A 4-week randomized controlled trial. Int J Dent Hyg 2023; 21:659-668. [PMID: 37753575 DOI: 10.1111/idh.12770] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 09/12/2023] [Accepted: 09/13/2023] [Indexed: 09/28/2023]
Abstract
BACKGROUND The primary prevention of periodontitis is controlling gingivitis daily. The study objective was to compare the efficacy of a pulsating water flosser to a pulsating water flosser infused with air microbubbles on clinical signs of inflammation and plaque. METHODS One hundred and five participants were enrolled in this single-blind, single-centre, parallel, 4-week, IRB/IEC-approved clinical trial. Participants were randomly assigned to one of three groups: water flosser (WF) plus manual toothbrush, water flosser infused with microbubbles of air (MBWF) plus manual toothbrush, or dental floss (DF) plus manual toothbrush. Bleeding on probing (BOP), Modified Gingival Index (MGI) and Rustogi Modification Navy Plaque Index (RMNPI) scores were recorded at baseline, 2 and 4 weeks. RESULTS All participants completed the study (n = 105). All groups showed a statistically significant reduction for BOP, MGI and RMNPI at 4 weeks (p < 0.05, except DF marginal RMNPI). The WF group showed a statistically significant greater reduction in whole mouth BOP (0.41) compared to MBWF (0.32) and DF (0.19). This was also true for MGI (0.37, 0.30 and 0.20, respectively) and RMNPI (0.13, 0.11 and 0.06, respectively; p < 0.05 for all comparisons). No adverse events were reported. CONCLUSION This study demonstrates that a manual toothbrush and water flosser, with or without microbubbles, is an effective oral care regimen for controlling gingivitis over 4 weeks.
Collapse
Affiliation(s)
- Deborah Mancinelli-Lyle
- Department of Periodontology, Academic Center for Dentistry, University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
| | - Jimmy G Qaqish
- All Sum Research Center, Ltd, Mississauga, Ontario, Canada
| | - C Ram Goyal
- All Sum Research Center, Ltd, Mississauga, Ontario, Canada
| | | |
Collapse
|
2
|
Mancinelli-Lyle D, Qaqish JG, Goyal CR, Schuller R. Efficacy of water flossing on clinical parameters of inflammation and plaque: A four-week randomized controlled trial. J Dent Hyg 2023; 97:166-186. [PMID: 37816609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Accepted: 09/12/2023] [Indexed: 10/12/2023]
Abstract
Purpose The primary prevention of periodontitis is controlling gingivitis daily. The study objective was to compare the efficacy of a pulsating water flosser to a pulsating water flosser infused with air microbubbles on clinical signs of inflammation and plaque.Methods One hundred and five participants were enrolled in this single-blind, single-center, parallel, four-week, IRB/IEC-approved clinical trial. Participants were randomly assigned to one of three groups: water flosser (WF) plus manual toothbrush, water flosser infused with microbubbles of air (MBWF) plus manual toothbrush, or dental floss (DF) plus manual toothbrush. Bleeding on probing (BOP), Modified Gingival Index (MGI), and Rustogi Modification Navy Plaque Index (RMNPI) scores were recorded at baseline, 2-weeks, and 4-weeks.Results All participants completed the study (n=105). All groups showed a statistically significant reduction for BOP, MGI, and RMNPI at 4-weeks (p<0.05, except DF marginal RMNPI). The WF group showed a statistically significant greater reduction in whole mouth BOP (0.41) compared to MBWF (0.32) and DF (0.19). This was also true for MGI (0.37, 0.30, and 0.20, respectively) and RMNPI (0.13, 0.11, and 0.06, respectively) (p<0.05 for all comparisons). No adverse events were reported.Conclusion This study demonstrates that a manual toothbrush and water flosser, with or without microbubbles, is an effective oral care regimen for controlling gingivitis over four weeks.
Collapse
Affiliation(s)
- Deborah Mancinelli-Lyle
- Department of Periodontology, Academic Center for Dentistry, University of Amsterdam and Vrije Universiteit Amsterdam, Amsterdam, NL
| | | | - C Ram Goyal
- All Sum Research Center, Ltd., Mississauga, Ontario, CA
| | | |
Collapse
|
3
|
Mancinelli-Lyle D, Qaqish JG, Goyal CR, Schuller R. Effectiveness of a Sonic-Flosser Toothbrush with a Different Size Brush Heads and Manual Toothbrush plus Dental Floss on Plaque, Gingival Bleeding and Inflammation in Adults with Naturally Occurring Gingivitis: A 4-Week Randomized Controlled Trial. Int J Dent Hyg 2023. [PMID: 36951212 DOI: 10.1111/idh.12675] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 12/08/2022] [Accepted: 03/04/2023] [Indexed: 03/24/2023]
Abstract
OBJECTIVE To compare the effectiveness of three oral hygiene groups: a novel sonic-flosser toothbrush with a compact brush head, a novel sonic-flosser toothbrush with a full size brush head and manual toothbrush plus dental floss on the reduction of gingival bleeding after 4 weeks. Secondarily, the groups were compared on the reduction of gingival inflammation and dental plaque. MATERIALS AND METHODS One hundred and five (n=105) healthy adults were enrolled in this randomized, examiner-blind, three-group, parallel clinical trial. Subjects were assigned to one of three groups: sonic-flosser toothbrush with full size brush head (SFF), sonic-flosser toothbrush with compact brush head (SFC), or manual toothbrush and string floss (MTF). Bleeding on probing (BOP), Modified Gingival Index (MGI), and Rustogi Modification of the Navy Plaque Index (RMNPI) scores were recorded at baseline, 2-weeks, and 4-weeks. RESULTS All subjects completed the study. All three groups demonstrated a significant reduction in BOP, MGI and RMNPI from baseline to 4-weeks for all areas recorded (p<0.001), except gingival margin plaque scores for SFF, SFC and MTF (p=0.203, p=0.082, p=0.324 respectively). Both the SFF and SFC groups were statistically more effective than MTF for whole mouth BOP, MGI and RMNPI (p<0.001) and proximal areas (p=0.022 or less). There were no adverse events reported by the subjects or identified by the examiner during the study. CONCLUSION The sonic-flosser toothbrush with a full size or compact brush head was statistically and clinically more effective at improving gingival health and reducing plaque than manual toothbrush and dental floss for adults with naturally occurring gingivitis over 4-weeks.
Collapse
Affiliation(s)
| | - Jimmy G Qaqish
- All Sum Research Center, LLC, Mississauga, Ontario, Canada
| | - C Ram Goyal
- All Sum Research Center, LLC, Mississauga, Ontario, Canada
| | | |
Collapse
|
4
|
Francis M, Hooper WJ, Worob D, Huy G, Santos S, Goyal CR, Qaqish K, Qaqish JG, Ghassemi A. Comparative plaque removal efficacy of a new children's powered toothbrush and a manual toothbrush: Randomized, single use clinical study. Am J Dent 2021; 34:338-344. [PMID: 35051323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
PURPOSE To compare the plaque removal efficacy of a new children's powered toothbrush to a children's manual toothbrush. METHODS 55 subjects aged 5-8 years old, who met entry criteria, participated in this single-center, two-cell, examiner-blind, randomized, crossover, single use clinical study. Subjects brushed at home with their first assigned toothbrush and fluoride toothpaste, under supervision of a parent or legal guardian, at least once daily for 2 minutes during a 1-week acclimation period. After refraining from oral hygiene for 12-16 hours, and from eating and drinking for 4 hours, subjects returned to the clinical site where they were assessed for plaque using the Rustogi Modified Navy Plaque Index (RMNPI). Subjects then brushed their teeth with their assigned toothbrush and toothpaste for 2 minutes and plaque levels were reassessed. Subjects were then given their second assigned toothbrush and the acclimation period and clinical site visit were repeated. Safety-in-use was also assessed during each clinic visit. Differences between pre-and post-brushing scores were analyzed for each toothbrush and between toothbrush groups for whole mouth plaque and 12 subset sites using baseline adjusted ANCOVA. RESULTS Both toothbrushes significantly (P< 0.0001) reduced whole mouth and 12 subset site plaque scores from the pre-brushing baseline. Between treatment comparisons showed that use of the powered toothbrush resulted in statistically significant reductions in whole mouth plaque (55%, P< 0.0001) and in 12 subset site scores (40-208%) compared to the manual brush. This clinical study showed that brushing with a new children's powered toothbrush was safe and significantly more effective than brushing with a manual toothbrush in reducing whole mouth plaque scores, as well as plaque scores at a range of subset sites in the mouth. CLINICAL SIGNIFICANCE This new powered toothbrush may enable children to safely achieve significant and meaningful improvements in oral hygiene compared to brushing with a manual toothbrush.
Collapse
Affiliation(s)
- Mary Francis
- Church and Dwight Co. Inc., Princeton, New Jersey, USA
| | | | - Drew Worob
- Church and Dwight Co. Inc., Princeton, New Jersey, USA
| | - Gerhart Huy
- Church and Dwight Co. Inc., Princeton, New Jersey, USA
| | - Sylvia Santos
- SLS Research Consulting, LLC, Pine Brook, New Jersey, USA
| | - C Ram Goyal
- All Sum Research Center Ltd., Mississauga, Ontario, Canada
| | | | - Jimmy G Qaqish
- All Sum Research Center Ltd., Mississauga, Ontario, Canada
| | | |
Collapse
|
5
|
Sharma NC, Goyal CR, Qaqish JG, Vorwerk LM, Hooper WJ, Ghassemi A. Enhanced plaque removal to improve gingival health: 3-month randomized clinical study of the effects of baking soda toothpaste on plaque and gingivitis. Am J Dent 2020; 33:258-264. [PMID: 33017529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
PURPOSE To compare the effectiveness in reducing plaque and gingivitis of a fluoride toothpaste with 20% baking soda and a fluoride toothpaste control. METHODS 159 subjects, who met the entry criteria, participated in this single-center, double-blind, randomized, parallel-group clinical study. Gingival Index (MGI), Gingival Bleeding Index (GBI), and Plaque Index (PI) were assessed after 4, 8, and 12 weeks use of the assigned test or control toothpaste. After 12 weeks, participants resumed 4 weeks of their customary oral hygiene after which they were re-evaluated using the same measures. RESULTS Both toothpastes statistically significantly reduced MGI, GBI, and PI versus baseline at all-time points. Brushing with the 20% baking soda toothpaste statistically significantly reduced MGI, PI, and GBI compared to the control toothpaste at all time points. After 12 weeks, the reductions in MGI, PI, and GBI were 12.6%, 9.6%, and 44.2%, respectively. After the 4-week customary oral hygiene period, the benefits of the study period had begun to diminish, but statistically significant reductions in MGI and GBI for the test versus control were still evident. This 3-month clinical study shows that brushing with fluoride toothpaste containing 20% baking soda reduces dental plaque and concurrently reduces gingival inflammation and bleeding compared to toothpaste with fluoride alone. CLINICAL SIGNIFICANCE Fluoride toothpaste with 20% baking soda has the potential to offer multiple oral health benefits when used as an adjunct to regular tooth brushing and, therefore, may be confidently recommended to patients.
Collapse
Affiliation(s)
| | - C R Goyal
- BioSci Research Canada Ltd., Mississauga, Canada
| | | | - Linda M Vorwerk
- Sr. Clinical Research Scientist, Church and Dwight Co., Inc., Princeton, New Jersey, USA
| | - William J Hooper
- Program Scientist, Church and Dwight Co., Inc., Princeton, New Jersey, USA
| | - Annahita Ghassemi
- Global Product Safety & Clinical Affairs, Church and Dwight Co., Inc., Princeton, New Jersey, USA,
| |
Collapse
|
6
|
Ghassemi A, Hooper WJ, Vorwerk LM, Petrovicova E, Goyal CR, Qaqish K, Qaqish JG, Santos S. The effects of two baking-soda toothpastes in enhancing mechanical plaque removal and improving gingival health: A 6-month randomized clinical study. Am J Dent 2020; 33:265-272. [PMID: 33017530] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
PURPOSE To compare the effectiveness in reducing plaque and gingivitis of two fluoride toothpastes containing baking soda (35% and 20%) with a fluoride toothpaste control. METHODS 319 subjects, who met entry criteria, participated in this single-center, three-cell, double-blind, randomized, parallel-group clinical study. Gingival Index (MGI), Gingival Bleeding Index (GBI), and Plaque Index (PI) were assessed at baseline, and after 6 weeks, 3 and 6 months. RESULTS All three toothpastes significantly (P< 0.0001) reduced MGI, GBI, and PI versus baseline, and the two baking soda toothpastes significantly (P< 0.0001) reduced MGI, GBI, and PI compared to the fluoride control, at all three time points. After 6 months use, the 35% and 20% baking soda toothpastes had reduced MGI, GBI and PI by 15.0%, 46.9%, and 18.3%, and 9.4%, 25.9%, and 12.4%, respectively, compared to the control. In addition, the 35% baking soda toothpaste had reduced (P≤ 0.0005) MGI, GBI, and PI by 6.2%, 28.4%, and 6.8%, respectively, compared to the 20% baking soda toothpaste. This clinical study showed that brushing with fluoride toothpastes containing baking soda at 35% and 20% reduces plaque, gingival inflammation and bleeding more effectively than regular fluoride toothpaste. Further, it showed that 35% baking soda toothpaste was more effective in reducing these parameters than 20% baking soda toothpaste. CLINICAL SIGNIFICANCE Fluoride toothpastes containing 20% or more baking soda can provide significant and meaningful gingival health benefits when used regularly as an adjunct to tooth brushing.
Collapse
Affiliation(s)
- Annahita Ghassemi
- Global Product Safety & Clinical Affairs, Church and Dwight Co., Inc., Princeton, New Jersey, USA,
| | - William J Hooper
- Program Scientist, Church and Dwight Co., Inc., Princeton, New Jersey, USA
| | - Linda M Vorwerk
- Sr. Clinical Research Scientist, Church and Dwight Co., Inc., Princeton, New Jersey, USA
| | - Elena Petrovicova
- Personal Care R&D, Church and Dwight Co. Inc., Princeton, New Jersey, USA
| | - C R Goyal
- Independent Clinical Investigator, All Sum Research Center Ltd., Mississauga, Canada
| | - Kathleen Qaqish
- Independent Clinical Investigator, All Sum Research Center Ltd., Mississauga, Canada
| | - Jimmy G Qaqish
- Independent Clinical Investigator, All Sum Research Center Ltd., Mississauga, Canada
| | - Sylvia Santos
- Consultant, SLS Clinical Reearch Consulting, LLC, Pine Brook, NJ, USA
| |
Collapse
|
7
|
Lyle DM, Qaqish JG, Goyal CR, Schuller R. Efficacy of the Use of a Water Flosser in Addition to an Electric Toothbrush on Clinical Signs of Inflammation: 4-Week Randomized Controlled Trial. Compend Contin Educ Dent 2020; 41:170-177. [PMID: 31904246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
UNLABELLED This study compared the use of an oscillating-rotating powered toothbrush and a water flosser to the use of an oscillating-rotating powered toothbrush on the reduction of clinical signs of inflammation and plaque. METHODS Seventy adult participants (N = 70) completed this examiner-blind, two-group, parallel clinical trial. The participants were randomized into either the water flosser + oscillating-rotating powered toothbrush (WF) group or the oscillating-rotating powered toothbrush only group (OR). Inflammation was measured by bleeding on probing (BOP) and modified gingival index (MGI) at baseline, 2 weeks, and 4 weeks. Plaque was scored using Rustogi Modification of the Navy Plaque Index (RMNPI) at the same timepoints. Data was reported for whole mouth, areas (marginal and proximal), and surfaces (facial and lingual). A post-study Likert scale questionnaire was completed at the 4-week visit. RESULTS Both groups demonstrated significant reductions in BOP, MGI, and RMNPI from baseline to 4 weeks for whole mouth (P < .001). The WF group was 37% more effective at reducing BOP, 36% for MGI, and 33% for RMNPI than the OR group at 4 weeks for whole mouth (P < .001; except RMNPI P = .003). Additionally, the WF group was significantly more effective at reducing proximal BOP (37%, P < .001), MGI (46%, P < .001), and RMNPI (52%, P = .004) compared to OR at 4 weeks. The questionnaire revealed subjects in both groups felt the device was easy to use, the instructions were clear, and their mouth felt fresh and clean. There were no adverse events reported during the study. CONCLUSION An oral hygiene regimen consisting of the use of a water flosser in addition to an oscillating-rotating powered toothbrush significantly improved gingival health. The products used in both groups were effective and well-tolerated by the study population.
Collapse
Affiliation(s)
- Deborah M Lyle
- Director of Professional and Clinical Affairs, Water Pik, Inc., Fort Collins, Colorado
| | - Jimmy G Qaqish
- Vice President of Operations, All Sum Research Center Ltd., Mississauga, Ontario, Canada
| | - C Ram Goyal
- President and Examiner, All Sum Research Center Ltd., Mississauga, Ontario, Canada
| | - Reinhard Schuller
- Owner and Statistician, Reinhard Schuller Consulting, Toronto, Ontario, Canada
| |
Collapse
|
8
|
Goyal CR, Qaqish JG, Schuller R, Lyle DM. Evaluation of the Addition of a Water Flosser to Manual Brushing on Gingival Health. J Clin Dent 2018; 29:81-86. [PMID: 30942963] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
OBJECTIVES The purpose of this clinical trial was to compare the use of a manual toothbrush plus water flosser to a manual toothbrush alone on clinical signs of inflammation. METHODS Seventy-two subjects were randomized into two groups and completed this four-week, single-blind, parallel, clinical trial. Group 1 used a Waterpik®Water Flosser (WF) once daily and brushed with a manual toothbrush twice a day. Group 2 brushed twice a day with a manual toothbrush only (MT). Subjects in group 1 were provided written and verbal instructions for the water flosser and all participants used the toothpaste and manual brush provided, brushing as they normally do. Data were evaluated at baseline (BSL), two weeks (W2), and four weeks (W4) for bleeding on probing (BOP), Modified Gingival Index (MGI), and Rustogi Modification of the Navy Plaque Index (RMNPI). RESULTS Both groups showed a significant reduction from BSL for BOP, MGI, and RMNPI at W2 and W4, except for MT W2 facial proximal MGI (p = 0.153) and marginal RMNPI (p = 0.324). The WF was significantly more effective than the MT for reducing BOP, MGI, and RMNPI at W2 and W4 for all areas measured. The WF was 3.13 times as effective for reducing BOP, 2.69 times for MGI, and 2.44 times for RMNPI at W4 (p < 0.001) for whole mouth scores. CONCLUSIONS The addition of the Waterpik®Water Flosser to manual tooth brushing is significantly more effective for improving gingival health than manual tooth brushing alone.
Collapse
Affiliation(s)
- C Ram Goyal
- All Sum Research Center, Mississauga, Ontario, Canada
| | | | | | | |
Collapse
|
9
|
Friesen LR, Goyal CR, Qaqish JG, He T, Eusebio R, Zsiska M, Farmer T, Schneiderman E. Comparative Antiplaque Effect of Two Antimicrobial Dentifrices: Laboratory and Clinical Evaluations. J Clin Dent 2017; 28:B6-B11. [PMID: 29334435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
OBJECTIVES To compare the effect of a stannous fluoride dentifrice versus a triclosan-containing dentifrice on the reduction of plaque using in vitro and clinical models. METHODS Both investigations evaluated a novel 0.454% stabilized stannous fluoride dentifrice (Crest® Pro-Health™ smooth formula) versus a sodium fluoride/triclosan positive control dentifrice (Colgate® Total®). The in vitro evaluation utilized the Plaque Glycolysis and Regrowth Model (PGRM), wherein the metabolic effects (acid production/glycolysis inhibition) of the dentifrices were assessed on plaque biofilms grown on glass rods after three days growth and a single dentifrice treatment. Treatments were evaluated via analysis of variance, Student's t-test. The clinical trial was a four-week, single-center, randomized and controlled, double-blind, parallel group study, where 120 adults were randomized to one of the two dentifrices for use at home according to manufacturer's instructions. Plaque was evaluated at baseline and Week 4 with the Rustogi Modified Navy Plaque Index (RMNPI). Statistical analyses were via analysis of covariance. RESULTS In vitro PGRM: The stannous fluoride dentifrice provided 43.3% glycolysis inhibition compared to 27.5% for the triclosan control, and the pH decrease associated with acid production was significantly less for stannous fluoride (0.87) versus triclosan (1.11); p < 0.05. Clinical trial: One hundred eighteen (118) subjects completed the study with fully evaluable data. Both dentifrice groups demonstrated statistically significant (p < 0.0001) reductions in plaque at Week 4 compared with baseline, with the stannous fluoride dentifrice producing a significantly lower adjusted mean Week 4 plaque score (p < 0.0001) versus the triclosan positive control for whole mouth plaque (23.1% lower) and interproximal plaque (43.5% lower). Both dentifrices were well-tolerated. CONCLUSIONS The stabilized stannous fluoride dentifrice provided statistically significant reductions in plaque glycolysis in vitro and plaque growth in vivo compared to the triclosan dentifrice. Results for both studies were consistent.
Collapse
Affiliation(s)
- Lynn R Friesen
- University of Kansas City-Missouri School of Dentistry, Kansas City, MO, USA
| | - C R Goyal
- All Sum Research, Mississauga, Ontario, Canada
| | | | - Tao He
- Procter & Gamble, Mason, OH, USA
| | | | | | | | | |
Collapse
|
10
|
He T, Eusebio R, Goyal CR, Qaqish JG. Assessment of the Effects of a Novel Stabilized Stannous Fluoride Dentifrice on Gingivitis in a Two-Month Positive-Controlled Clinical Study. J Clin Dent 2017; 28:B12-B16. [PMID: 29334436] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
OBJECTIVES The aim of this study was to compare the antibleeding/antigingivitis effectiveness of a newly formulated 0.454% stabilized stannous fluoride dentifrice and a marketed positive control triclosan-containing dentifrice in adults with mild-to-moderate gingivitis. METHODS This single-center, two-month, randomized and controlled, double-blind, parallel group clinical trial involved adults with preexisting mild-to-moderate gingivitis. Baseline bleeding and gingivitis levels were assessed with the Gingival Bleeding Index (GBI) and Lobene Modified Gingival Index (MGI). Subjects were randomly assigned to either a new smooth formula 0.454% stabilized stannous fluoride test dentifrice (Crest® Pro-Health™) or a commercially available positive control 0.30% triclosan dentifrice (Colgate® Total®). Subjects brushed with their assigned dentifrice at home according to the manufacturer's instructions. At Month 2, subjects were re-evaluated for bleeding and gingivitis as at Baseline, with MGI and GBI evaluations. RESULTS Of the 200 subjects randomized to treatment, 197 completed the study and had fully evaluable data. At Month 2, both the stannous fluoride and triclosan control dentifrices produced statistically significant reductions (p < 0.0001) in the mean number of bleeding sites, MGI, and GBI compared to Baseline. Use of this 0.454% stannous fluoride dentifrice resulted in 22% fewer bleeding sites versus the positive control triclosan dentifrice (p < 0.0001). Similarly, after two months of brushing, the stannous fluoride dentifrice group showed statistically significant lower mean MGI and GBI scores than subjects using the triclosan positive control dentifrice (p < 0.0001). Both dentifrices were well-tolerated. CONCLUSIONS Subjects brushing with a newly formulated stannous fluoride dentifrice had statistically significantly fewer bleeding sites and less gingivitis than those using a positive control triclosan dentifrice after two months.
Collapse
Affiliation(s)
- Tao He
- Procter & Gamble, Mason, OH, USA
| | | | - C R Goyal
- All Sum Research, Mississauga, Ontario, Canada
| | | |
Collapse
|
11
|
Goyal CR, Lyle DM, Qaqish JG, Schuller R. Comparison of Water Flosser and Interdental Brush on Reduction of Gingival Bleeding and Plaque: A Randomized Controlled Pilot Study. J Clin Dent 2016; 27:61-65. [PMID: 28390208] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
OBJECTIVES The purpose of this randomized, two-week, single blind, two-group parallel pilot study was to compare the reduction in gingival bleeding and plaque in subjects using a water flosser or interdental brush, each combined with a manual toothbrush. METHODS Twenty-eight subjects completed the study. Subjects were randomly assigned to one of two groups: Waterpik® Water Flosser (WF) plus manual toothbrush or interdental brushes (IDBs) plus a manual toothbrush. Bleeding on probing (BOP) was measured at six sites and reported for whole mouth, lingual, facial, and interproximal areas. Plaque data were measured using the Rustogi Modification of the Navy Plaque Index (RMNPI) and were reported for whole mouth, approximal, marginal, facial, and lingual areas. Subjects received verbal and written instructions on the use of their interdental product and demonstrated proficiency prior to starting the study. RESULTS There were no differences between the groups for BOP or RMNPI at baseline. Both groups demonstrated a significant reduction in BOP and RMNPI for all regions and areas measured from baseline to two weeks. The WF was more effective than the IDBs for BOP whole mouth (56%), facial (44%), approximal whole mouth (53%), and approximal facial (41%). Post hoc power analysis showed that the sample size was not adequate to detect a significant difference between groups for lingual and marginal assessments for BOP or any area for RMNPI. CONCLUSIONS The Waterpik Water Flosser is more effective than IDBs for reducing gingival bleeding over two weeks.
Collapse
Affiliation(s)
- C Ram Goyal
- All Sum Research Center Mississauga, Ontario, Canada
| | | | | | | |
Collapse
|
12
|
Lyle DM, Goyal CR, Qaqish JG, Schuller R. Comparison of Water Flosser and Interdental Brush on Plaque Removal: A Single-Use Pilot Study. J Clin Dent 2016; 27:23-26. [PMID: 28390213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
OBJECTIVES The purpose of this randomized, single-use, single-blind, two-group, parallel pilot study was to compare the plaque removal ability of a water flosser and interdental brush when used in combination with a manual toothbrush. METHODS Twenty-eight (28) subjects completed the study. Subjects were randomly assigned to one of two groups: Waterpik®Water Flosser (WF) plus manual tooth brushing or interdental brushes (IDB) plus manual tooth brushing. Pre-cleaning plaque scores were obtained using the Rustogi Modification of the Navy Plaque Index (RMNPI). Subjects were instructed on the use of their interdental product. Post-cleaning scores were obtained after a supervised brushing and use of the interdental device. Scores were recorded for whole mouth, marginal, approximal, facial, and lingual regions for each subject. RESULTS There were no differences between the groups for pre-cleaning plaque scores for whole mouth, marginal, approximal, facial, or lingual regions. Both groups showed significant reductions in plaque from baseline for all areas measured (p < 0.001). The WF group was significantly more effective than the IDB group for removing plaque from all areas measured. Specifically, the WF was 18% more effective for whole mouth and marginal areas, 20% for approximal areas, 11% for facial areas, and 29% for lingual areas. CONCLUSIONS The Waterpik Water Flosser and manual toothbrush removes significantly more plaque from tooth surfaces (whole mouth, marginal, approximal, facial, and lingual) than interdental brushes and a manual toothbrush after a single use.
Collapse
Affiliation(s)
| | - C Ram Goyal
- All Sum Research Center, Mississauga, Ontario, Canada
| | | | | |
Collapse
|
13
|
Goyal CR, Lyle DM, Qaqish JG, Schuller R. Efficacy of Two Interdental Cleaning Devices on Clinical Signs of Inflammation: A Four-Week Randomized Controlled Trial. J Clin Dent 2015; 26:55-60. [PMID: 26349127] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
OBJECTIVE The purpose of this study was to compare the reduction of the clinical signs of inflammation by two power interdental cleaning devices combined with a manual toothbrush. METHODS Sixty-nine subjects completed this randomized, four-week, single-blind, two-group, parallel clinical study. Subjects were randomly assigned to one of two treatment groups: Waterpik Water Flosser (WF) plus a manual toothbrush; or Sonicare Air Floss Pro (AFP) plus a manual toothbrush. All subjects received both written and verbal instructions and demonstrated proficiency prior to starting the study. Instructions were reviewed at the two-week visit (W2). Data were evaluated for whole mouth, lingual, and facial areas for bleeding on probing (BOP) and Modified Gingival Index (MGI). Plaque data were recorded for whole mouth, lingual, facial, approximal, and marginal areas of the tooth using the Rustogi Modification of the Navy Plaque Index (RMNPI). BOP, MGI, and RMNPI were scored at baseline (BSL), two weeks, and four weeks (W4). RESULTS Both groups showed significant reductions in BOP and MGI from baseline for all regions and time points measured (p < 0.001). Both groups showed significant reductions from baseline for all areas at W4 for RMNPI (p < 0.001). The WF group was significantly more effective than the AFP group at reducing bleeding and gingivitis for all areas measured at all time points. At W4, the WF group was 54% more effective for bleeding and 32% for gingivitis (p < 0.001). Plaque accumulation was significantly less at W4 for the WF group compared to the AFP group (28%, p 0.017). CONCLUSIONS The Waterpik Water Flosser is significantly more effective than the Sonicare Air Floss Pro for reducing clinical signs of inflammation.
Collapse
|
14
|
Goyal CR, Lyle DM, Qaqish JG, Schuller R. Evaluation of the plaque removal efficacy of a water flosser compared to string floss in adults after a single use. J Clin Dent 2013; 24:37-42. [PMID: 24282867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
OBJECTIVE To compare the plaque removal efficacy of a water flosser to string floss combined with a manual toothbrush after a single use. METHODS Seventy adult subjects participated in this randomized, single-use, single-blind, parallel clinical study. Subjects were assigned to one of two groups; Waterpik Water Flosser plus a manual toothbrush (WF) or waxed string floss plus a manual toothbrush (SF). Each participant brushed for two minutes using the Bass technique. The WF group added 500 ml of warm water to the reservoir and followed the manufacturer's instructions, and the SF group used waxed string floss between each tooth, cleaning the mesial and distal surfaces as instructed. Subjects were observed to ensure they covered all areas and followed instructions. Scores were recorded for whole mouth, marginal, approximal, facial, and lingual regions for each subject using the Rustogi Modification of the Navy Plaque Index. RESULTS The WF group had a 74.4% reduction in whole mouth plaque and 81.6% for approximal plaque compared to 57.7% and 63.4% for the SF group, respectively (p < 0.001). The differences between the groups showed the water flosser was 29% more effective than string floss for overall plaque removal and approximal surfaces specifically (p < 0.001). The WF group was more effective in removing plaque from the marginal, lingual, and facial regions; 33%, 39%, and 24%, respectively (p < 0.001). CONCLUSION The Waterpik Water Flosser and manual toothbrush is significantly more effective than a manual brush and string floss in removing plaque from tooth surfaces.
Collapse
Affiliation(s)
- C Ram Goyal
- BioSci Research Canada Ltd., Mississauga, Ontario, Canada
| | | | | | | |
Collapse
|
15
|
Goyal CR, Lyle DM, Qaqish JG, Schuller R. The addition of a water flosser to power tooth brushing: effect on bleeding, gingivitis, and plaque. J Clin Dent 2012; 23:57-63. [PMID: 22779218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
OBJECTIVE The primary objective of this study was to compare the effectiveness of a water flosser plus sonic toothbrush to a sonic toothbrush alone on the reduction of bleeding, gingivitis, and plaque. The secondary objective was to compare the effectiveness of different sonic toothbrushes on bleeding, gingivitis, and plaque. METHODS One-hundred and thirty-nine subjects completed this randomized, four-week, single-masked, parallel clinical study. Subjects were assigned to one of four groups: Waterpik Complete Care, which is a combination of a water flosser plus power toothbrush (WFS); Sensonic Professional Plus Toothbrush (SPP); Sonicare FlexCare toothbrush (SF); or an Oral-B Indicator manual toothbrush (MT). Subjects were provided written and verbal instructions for all power products at baseline, and instructions were reviewed at the two-week visit. Data were evaluated for whole mouth, facial, and lingual surfaces for bleeding on probing (BOP) and gingivitis (MGI). Plaque data were evaluated for whole mouth, lingual, facial, approximal, and marginal areas of the tooth using the Rustogi Modification of the Navy Plaque Index (RMNPI). Data were recorded at baseline (BL), two weeks (W2), and four weeks (W4). RESULTS All groups showed a significant reduction from BL in BOP, MGI, and RMNPI for all areas measured at the W2 and W4 visits (p < 0.001). The reduction of BOP was significantly higher for the WFS group than the other three groups at W2 and W4 for all areas measured (p < 0.001 for all, except p = 0.007 at W2 and p = 0.008 for W4 lingual comparison to SPP). The WFS group was 34% more effective than the SPP group, 70% more effective than the SF group, and 1.59 times more effective than the MT group for whole mouth bleeding scores (p < 0.001) at W4. The reduction of MGI was significantly higher for the WFS group; 23% more effective than SPP, 48% more effective than SF, and 1.35 times more effective than MT for whole mouth (p <0.001) at W4. The reduction of MGI was significantly higher for WFS than the SF and MT for facial and lingual surfaces, and more effective than the SPP for facial surfaces (p < 0.001) at W4. The WFS group showed significantly better reductions for plaque than the SF and MT groups for whole mouth, facial, lingual, approximal, and marginal areas at W4 (p < 0.001; SF facial p = 0.025). For plaque reduction, the WFS was significantly better than the SPP for whole mouth (p = 0.003) and comparable for all other areas and surfaces at W4. The WFS was 52% more effective for whole mouth, 31% for facial, 77% for lingual, 1.22 times for approximal, and 1.67 times for marginal areas compared to the SF for reducing plaque scores at W4 (p < 0.001; SF facial p = 0.025). The SPP had significantly higher reductions than the SF for whole mouth and lingual BOP and MGI scores, and whole mouth, approximal, marginal, and lingual areas for plaque at W4. CONCLUSION The Waterpik Complete Care is significantly more effective than the Sonicare FlexCare toothbrush for reducing gingival bleeding, gingivitis, and plaque. The Sensonic Professional Plus Toothbrush is significantly more effective than the Sonicare Flex-Care for reducing gingival bleeding, gingivitis, and plaque.
Collapse
Affiliation(s)
- C Ram Goyal
- BioSci Research Canada Ltd., Mississauga, Ontario, Canada
| | | | | | | |
Collapse
|
16
|
Sharma NC, Lyle DM, Qaqish JG, Schuller R. Comparison of two power interdental cleaning devices on plaque removal. J Clin Dent 2012; 23:17-21. [PMID: 22435320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
OBJECTIVE The objective of this randomized, single-use, single-blind, two-group, parallel clinical trial was to evaluate the supragingival plaque removal efficacy of two power interdental devices combined with a manual toothbrush. METHODS Eighty-two (82) subjects completed the study. Subjects were randomly assigned to one of two groups: Waterpik Water Flosser (WF) plus manual tooth brushing or Sonicare Air Floss (AF) plus manual tooth brushing. Pre-brushing and interdental cleaning scores were obtained using the Rustogi Modified Navy Plaque Index (RMNPI). Subjects were instructed on the use of the manual toothbrush and assigned an interdental product. Post-brushing and interdental cleaning scores were obtained after a supervised two-minute brushing and use of the interdental device. Scores were recorded for whole mouth, marginal, approximal, facial, and lingual regions for each subject. RESULTS There were no differences in the pre-cleaning plaque scores for whole mouth, marginal, approximal, facial, or lingual regions. Both groups showed significant reductions in plaque from baseline for all regions. The WF group demonstrated significantly higher reductions as measured by the RMNPI compared to the AF for whole mouth (74.9% vs. 57.5%), marginal (58.6% vs. 36.7%), approximal (92.1% vs. 77.4%), facial (83.6% vs. 69.1%), and lingual (65.7% vs. 45.4%). CONCLUSION The use of the Waterpik Water Flosser removes significantly more plaque from tooth surfaces (whole mouth, marginal, approximal, facial, and lingual) than the Sonicare Air Floss when used with a manual toothbrush.
Collapse
|
17
|
Sharma NC, Lyle DM, Qaqish JG, Schuller R. Comparison of two power interdental cleaning devices on the reduction of gingivitis. J Clin Dent 2012; 23:22-26. [PMID: 22435321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
OBJECTIVE The objective of this study was to compare the reduction of gingivitis by two power interdental devices combined with a manual toothbrush. METHODS Eighty-two subjects completed this randomized, four-week, single-blind, two-group parallel clinical study. Subjects were randomly assigned to one of two groups: Waterpik Water Flosser (WF) plus manual tooth brushing or Sonicare Air Floss (AF) plus manual tooth brushing. Subjects were provided written and verbal instructions for all products at the baseline visit and instructions were reviewed at the two-week (W2) visit. Data were evaluated for whole mouth, lingual, and facial areas for gingivitis and bleeding on probing. Plaque data were evaluated for whole mouth, lingual, facial, approximal, and marginal areas of the tooth. Gingivitis, bleeding on probing, and plaque were scored at baseline (BSL), two weeks, and four weeks (W4). RESULTS Both groups showed significant reductions in gingivitis, bleeding on probing, and plaque from baseline for all regions and time points measured (p < 0.001). The WF group was significantly more effective than the AF group at reducing plaque and gingivitis at W2 and W4 for all areas measured (p <0.001). At W4, the WF group was 80% more effective than AF for whole mouth gingivitis reduction, and twice as effective for the lingual region. In terms of plaque removal at W4, the WF group was 70% more effective for whole mouth (50.9% vs. 30%), 60% for approximal area (76.7% vs. 48%), and 47% for facial (52.8% vs. 35.9%) surfaces. The WF was twice as effective for lingual areas and more than three times as effective for marginal areas vs. the AF group (p <0.001). Results for bleeding on probing showed the WF group was numerically better than the AF group for all areas and time points, with these improvements being statistically significance for whole mouth (p = 0.02) and facial area (p = 0.004) at W2, and for the facial area (p = 0.02) at W4. CONCLUSION The Waterpik Water Flosser is significantly more effective than Sonicare Air Floss for reducing gingivitis and plaque.
Collapse
|
18
|
Sharma NC, Qaqish JG, He T, Walters PA, Grender JM, Biesbrock AR. Plaque and gingivitis reduction efficacy of an advanced pulsonic toothbrush: a 4-week randomized and controlled clinical trial. Am J Dent 2010; 23:305-310. [PMID: 21344827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
PURPOSE To compare the safety and efficacy of a novel sonic power toothbrush and a manual toothbrush in the reduction of gingivitis and plaque over a 4-week period. METHODS This study employed a randomized two treatment, examiner-blinded, parallel group design. Subjects with evidence of gingivitis were randomly assigned to 4 weeks' twice daily home use of either the Oral-B Pulsonic sonic toothbrush or an ADA reference manual toothbrush. At baseline (Visit 1) and again after product use at Week 4, subjects received gingivitis evaluations with the Modified Gingival Index (MGI) and Gingival Bleeding Index (GBI) examinations, followed by plaque assessment using the Rustogi Modified Navy Plaque Index (RMNPI). For 12 hours before both visits, subjects abstained from all oral hygiene, and ceased eating, drinking and smoking 4 hours prior. RESULTS Both brushes significantly reduced gingivitis, gingival bleeding and plaque compared with baseline, and were well-tolerated by the 129 subjects completing the study. The sonic toothbrush was statistically significantly (P < 0.0001) more effective than the manual brush, with greater relative mean reductions in MGI, GBI and RMNPI of 11.9%, 62.3% and 46.5%, respectively.
Collapse
|
19
|
Biesbrock AR, Walters PA, Bartizek RD, Goyal CR, Qaqish JG. Plaque removal efficacy of an advanced rotation-oscillation power toothbrush versus a new sonic toothbrush. Am J Dent 2008; 21:185-188. [PMID: 18686772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
PURPOSE To evaluate the plaque removal efficacy and safety of an advanced rotation-oscillation power toothbrush relative to a newly-introduced sonic toothbrush. METHODS This study used a randomized, examiner-blind, two-treatment, four-period, four-sequence crossover design. Subjects received both toothbrushes (Oral-B Triumph and Sonicare FlexCare) and a standard dentifrice from the study site and used each toothbrush at home during an acclimation phase prior to their plaque measurement visits. After abstaining from all oral hygiene for 24 hours, subjects returned to the study site and were assessed with the Rustogi Modified Navy Plaque Index. They then brushed for 2 minutes with their first randomly-assigned toothbrush and post-brushing plaque scores were recorded. This procedure was followed for three additional study visits, with subjects using their normal at-home toothbrush and dentifrice for the 2- to 5-day washout periods between visits. Subjects always abstained from all oral hygiene for 24 hours prior to their visits. RESULTS 45 subjects completed the study. Both brushes were found to be safe and both significantly reduced plaque after a single brushing. Oral-B Triumph was statistically significantly (P < 0.0001) more effective in plaque removal than Sonicare FlexCare for whole mouth plaque scores, gingival marginal plaque scores and interproximal plaque scores. Compared to Sonicare FlexCare, the adjusted mean plaque reduction scores for Oral-B Triumph were 21%, 23% and 22% greater for whole mouth, marginal and interproximal areas, respectively.
Collapse
|
20
|
Goyal CR, Qaqish JG, Galustians J, Ortbald K. Efficacy and safety of a new power toothbrush in a population with mild to moderate gingivitis. J Clin Dent 2007; 18:65-9. [PMID: 17912998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
OBJECTIVE To evaluate the efficacy and safety of a novel ultrasound power toothbrush over a 30-day period in a population with mild to moderate gingivitis. METHODOLOGY A 30-day, randomized, examiner-blind, parallel-arm study was conducted to evaluate the safety and efficacy of a ultrasound novel power toothbrush (Ultreo - ULT) as compared to a control manual toothbrush (Oral-B 35-MTB). Fifty-three subjects (n = 26 ULT, n = 27 MTB) with a minimum of 18 natural teeth and a Löe and Silness Gingival Index of > or = 1.5 were enrolled. An intraoral examination (oral soft and hard tissues, restorations) was performed, and Löe and Silness Gingival Index scores were recorded at baseline and 30 days. Subjects were instructed to brush at home twice per day with their assigned toothbrush and study toothpaste. A product evaluation questionnaire was also completed at the 30-day study visit. RESULTS Oral examinations indicated normal findings at all time points for both groups, and no adverse events were reported during the study. There were no significant differences in gingivitis scores at baseline between the toothbrush groups (p > 0.05). From baseline, each treatment group demonstrated a significant reduction in gingivitis over the 30-day period (p < 0.001). However, subjects in the ULT group demonstrated a significantly greater reduction in gingivitis compared to those using the manual toothbrush (p = 0.010). Results from the questionnaire, on average, indicated subjects in the ULT group scored their device higher with respect to the clean feeling after brushing and perceived improvements in gingival health. CONCLUSION The novel Ultreo ultrasound power toothbrush significantly reduced gingivitis over the 30-day study, and resulted in a significantly greater reduction in gingivitis than a manual toothbrush. No adverse events or safety concerns were identified with either the power or manual toothbrush.
Collapse
Affiliation(s)
- C Ram Goyal
- BioSci Research Canada, Ltd. Mississauga, ON, Canada
| | | | | | | |
Collapse
|
21
|
Sharma NC, Lyle DM, Qaqish JG, Galustians J. Evaluation of the plaque removal efficacy of three power toothbrushes. J Int Acad Periodontol 2006; 8:83-8. [PMID: 16865997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
INTRODUCTION The objective of this randomized, single use, single blind, single center, 4-group parallel clinical study was to evaluate the plaque removal efficacy of three power toothbrushes and a manual toothbrush. METHODS One hundred forty-four (144) subjects completed the study. Subjects were randomly assigned to one of four toothbrush groups: Sonicare Elite, Oral-B Sonic Complete, Waterpik Sensonic or Oral-B Indicator (manual). Subjects abstained from brushing 23-25 hours prior to the pre-brushing data collection. Pre-brushing scores were obtained using the Rustogi modified navy plaque index (RMNPI). Post-brushing RMNPI scores were obtained after a supervised uninstructed two-minute brushing with the assigned toothbrush. Scores were recorded for whole mouth, marginal region, and approximal region for each subject. RESULTS Pre-brush comparability of whole mouth, marginal and approximal regions indicated no statistical differences among the four groups for any of the three measurement regions. All four toothbrushes showed statistically significant change from pre-brush to post-brush scores for whole mouth, marginal region, and approximal region. The Waterpik Sensonic provided significantly greater reduction in plaque as measured by the RMNPI compared to the other three brushes for whole mouth (89%), marginal area (81%) and approximal area (97%). The only exception was for adjusted p-values for the approximal area compared to the Oral-B Sonic Complete (p = 0.12). CONCLUSION All groups demonstrated a significant reduction in plaque. The single use plaque removal efficacy of the Waterpik Sensonic toothbrush compared favorably to the other two power toothbrushes, the Sonicare Elite and the Oral-B Sonic Complete, and compared favorably to the manual toothbrush, the Oral-B Indicator.
Collapse
|
22
|
Strate J, Cugini MA, Warren PR, Qaqish JG, Galustians HJ, Sharma NC. A comparison of the plaque removal efficacy of two power toothbrushes: Oral-b Professional Care Series versus Sonicare Elite. Int Dent J 2005; 55:151-6. [PMID: 15997965 DOI: 10.1111/j.1875-595x.2005.tb00312.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
AIM To compare the safety and plaque removal efficacy of an oscillating/ pulsating toothbrush (Professional Care Series, Oral-B Laboratories; PCS) and a high frequency toothbrush (Sonicare Elite, Philips Oral Healthcare; SE). METHODS The study had a randomised, examiner-blind, crossover design. Sixty-one subjects aged 19-64 years were enrolled. After 23-25 hours of no oral hygiene, subjects received an oral tissue examination and those with pre-brushing whole mouth mean plaque scores > or = 0.60 measured by the Rustogi modified Navy Plaque Index were randomly assigned to treatment sequence. Subjects brushed with their assigned toothbrush for 2 minutes using a commercially available dentifrice. Oral tissues were then re-examined and post-brushing plaque scores recorded. After a brief washout period, the above procedures were repeated with the alternate toothbrush. One examiner blinded to the treatment sequence performed all clinical measurements. RESULTS All 61 subjects completed the study. Both toothbrushes significantly reduced plaque levels after a single brushing (t-test, p < 0.0001). However, the PCS was significantly more effective than the SE in whole mouth plaque removal and in reducing plaque from marginal, buccal, lingual and approximal surfaces (ANOVA, p < 0.0001). Whole mouth plaque was reduced by 88% versus 61% and approximal plaque by 97% versus 73% for the PCS and SE toothbrushes, respectively. There was no evidence of hard or soft tissue trauma after a single-use of either toothbrush. CONCLUSION Based on the findings of this single-use clinical evaluation, the action of the oscillating/ pulsating power toothbrush is more effective at plaque removal than a high frequency power toothbrush.
Collapse
|
23
|
Sharma NC, Qaqish JG, Galustians HJ, Goyal CR, Cugini MA, Thompson MC, Warren PR. Plaque removal efficacy of two electric toothbrushes with different brush head designs. J Dent 2005; 33S1:17-21. [PMID: 16253751] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2023] Open
Abstract
OBJECTIVES.: To compare the safety and plaque removal efficacy of two electric toothbrushes, one a rechargeable oscillating/pulsating toothbrush with a small round brush head (Oral-B ProfessionalCaretrade mark 7000; PC 7000), the other a battery-operated toothbrush with a dual moving brush head (Crest(R) SpinBrushtrade mark Pro; SBP). METHODS.: The study had a randomised, examiner-blind, two-arm crossover design. All subjects received an oral prophylaxis and used both toothbrushes on alternating days for a two-week practice period. After abstaining from all oral hygiene procedures for 23-25 hours, subjects received an oral tissue examination and those with pre-brushing whole mouth mean plaque scores >/=0.60 measured by the Rustogi et al. Modified Navy Plaque Index were randomly assigned to treatment sequence. Subjects brushed with their assigned toothbrush for 2 minutes using a commercially available dentifrice. Oral tissues were then re-examined and post-brushing plaque scores recorded. After a brief washout period, the above procedures were repeated with the alternate toothbrush. One examiner, blinded to the treatment sequence, performed all clinical measurements. RESULTS.: A total of 70 subjects (24 males and 46 females) were enrolled and completed the study. Each toothbrush was found to be safe and significantly reduced plaque levels after a single brushing. The PC 7000 was significantly more effective in plaque removal than the SBP at all tooth areas, reducing whole mouth plaque by 61% versus 58% and plaque from approximal surfaces by 69% versus 65%, respectively. CONCLUSIONS.: The action of the oscillating/pulsating toothbrush with a small round brush head, Oral-B ProfessionalCare 7000, is more effective in plaque removal than the battery-operated Crest SpinBrush Pro toothbrush with a larger dual moving brush head.
Collapse
Affiliation(s)
- N C Sharma
- BioSci Research Canada Ltd., 6245 Mississauga Road, Mississauga, Ontario L5N 1A4, Canada
| | | | | | | | | | | | | |
Collapse
|
24
|
Sharma NC, Goyal CR, Qaqish JG, Cugini MA, Thompson MC, Warren PR. Single-use plaque removal efficacy of three power toothbrushes. J Dent 2005; 33S1:11-15. [PMID: 16253750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2023] Open
Abstract
OBJECTIVES.: To compare the safety and plaque removal efficacy of two oscillating/rotating/pulsating toothbrushes (Oral-B ProfessionalCaretrade mark 7000 [PC 7000] and Oral-B 3D Excel [3DE]) and a high-frequency toothbrush (Sonicare(R) Advance, Philips Oral Healthcare; SA) in a single-use, examiner-blind, three period crossover study. METHODS.: After refraining from all oral hygiene procedures for 23-25 hours, subjects received an oral tissue examination and those with pre-brushing whole mouth mean plaque scores 0.6 based on the Rustogi et al. Modified Navy Plaque Index were randomly assigned to treatment sequence. After brushing with the assigned toothbrush and a commercially available dentifrice for 2 minutes, oral tissues were then re-examined and post-brushing plaque scores recorded. Following a brief washout period between two additional visits, the above procedures were repeated with the two alternate toothbrushes. One examiner, blinded to the treatment sequence, performed all clinical measurements. RESULTS.: A total of 79 subjects (28 males and 51 females) were enrolled and completed the study. Each toothbrush was found to be safe and significantly reduced plaque levels after a single brushing. The PC 7000 and 3DE were equally more effective in plaque removal than the SA, at all tooth areas, reducing plaque by 59.0%, 59.7% and 51.8%, respectively on whole mouth surfaces, and by 67.5%, 67.8% and 59.4%, respectively on approximal surfaces. CONCLUSIONS.: The action of the oscillating/rotating/pulsating toothbrushes (Oral-B ProfessionalCare 7000 and Oral-B 3D Excel) was more effective in plaque removal than the high-frequency toothbrush (Sonicare Advance).
Collapse
Affiliation(s)
- N C Sharma
- BioSci Research Canada Ltd., 6245 Mississauga Road, Mississauga, Ontario L5N 1A4, Canada
| | | | | | | | | | | |
Collapse
|
25
|
Goyal CR, Sharma NC, Qaqish JG, Cugini MA, Thompson MC, Warren PR. Efficacy of a novel brush head in the comparison of two power toothbrushes on removal of plaque and naturally occurring extrinsic stain. J Dent 2005; 33 Suppl 1:37-43. [PMID: 16208802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/04/2023] Open
Abstract
OBJECTIVES To compare the safety and efficacy of an oscillating/pulsating power toothbrush (Oral-B ProfessionalCareTM 7000; PC 7000) fitted with either the standard FlexiSoft (PC 7000/EB17) brush head or the novel Pro Polisher (PC 7000/ EB-Prophy) and a high-frequency toothbrush (Philips Sonicare Elite; SE), in their relative ability to remove plaque and naturally occurring extrinsic dental stain over a six-week period. METHODS This randomised, examiner-blind, parallel group study involved 90 healthy subjects from a general population. All subjects received a baseline plaque (Turesky et al. modified Quigley-Hein Plaque Index), stain (Lobene Stain Index) and tooth shade (VITAPAN Shade Guide) [Vita] assessment and an oral tissue examination. After training in the use of their randomly assigned device, subjects were instructed to brush twice daily for 2 min and returned after 3, 4 and 6 weeks of product use for a repeat of each clinical assessment. RESULTS Reductions from baseline in mean plaque and extrinsic dental stain scores were significant at Weeks 3, 4 and 6 in all three treatment groups. By Week 6, mean reductions from baseline in whole mouth plaque scores were 32%, 27% and 14% in the PC 7000/EB-Prophy, PC 7000/EB17 and SE groups, respectivety. For the body of the tooth, mean reductions from baseline at Week 6 in total stain were 89%, 89% and 80%, respectively. Between treatment group comparisons consistently revealed that the PC 7000 toothbrush plus the EB-Prophy or EB17 brush head removed significantly more plaque and extrinsic stain (total stain, stain area and stain intensity) than the SE toothbrush at 3, 4 and 6 weeks. The EB-Prophy group had a greater proportion of subjects showing a 2-3+ change in Vita shade scores at each time point compared to the other two brushes; at Week 6 the proportions were 67% in the PC 7000/EB-Prophy group, 30% in the PC 7000/EB17 group, and 7% in the SE group. The PC 7000/EB17, PC 7000/EB-Prophy and the SE were found to be safe as used in the study. CONCLUSIONS The oscillating/rotating/pulsating PC 7000 (fitted with either the standard EB17 or novel EB-Prophy brush head) is more effective at removal of plaque and naturally occurring extrinsic tooth stain, and the PC 7000 plus EB-Prophy in the improvement of tooth shade, than the high-frequency SE toothbrush.
Collapse
Affiliation(s)
- C R Goyal
- BioSci Research Canada Ltd., 6245 Mississauga Road, Mississauga, Ontario L5N 1A4, Canada
| | | | | | | | | | | |
Collapse
|
26
|
Sharma NC, Goyal CR, Qaqish JG, Cugini MA, Thompson MC, Warren PR. Single-use plaque removal efficacy of three power toothbrushes. J Dent 2005; 33 Suppl 1:11-5. [PMID: 16208798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/04/2023] Open
Abstract
OBJECTIVES To compare the safety and plaque removal efficacy of two oscillating/rotating/pulsating toothbrushes (Oral-B ProfessionalCare 7000 [PC 7000] and Oral-B 3D Excel [3DE]) and a high-frequency toothbrush (Sonicare Advance, Philips Oral Healthcare; SA) in a single-use, examiner-blind, three period crossover study. METHODS After refraining from all oral hygiene procedures for 23-25 hours, subjects received an oral tissue examination and those with pre-brushing whole mouth mean plaque scores > or = 0.6 based on the Rustogi et al. Modified Navy Plaque Index were randomly assigned to treatment sequence. After brushing with the assigned toothbrush and a commercially available dentifrice for 2 minutes, oral tissues were then re-examined and post-brushing plaque scores recorded. Following a brief washout period between two additional visits, the above procedures were repeated with the two alternate toothbrushes. One examiner, blinded to the treatment sequence, performed all clinical measurements. RESULTS A total of 79 subjects (28 males and 51 females) were enrolled and completed the study. Each toothbrush was found to be safe and significantly reduced plaque levels after a single brushing. The PC 7000 and 3DE were equally more effective in plaque removal than the SA, at all tooth areas, reducing plaque by 59.0%, 59.7% and 51.8%, respectively on whole mouth surfaces, and by 67.5%, 67.8% and 59.4%, respectively on approximal surfaces. CONCLUSIONS The action of the oscillating/rotating/pulsating toothbrushes (Oral-B ProfessionalCare 7000 and Oral-B 3D Excel) was more effective in plaque removal than the high-frequency toothbrush (Sonicare Advance).
Collapse
Affiliation(s)
- N C Sharma
- BioSci Research Canada Ltd., 6245 Mississauga Road, Mississauga, Ontario L5N 1A4, Canada
| | | | | | | | | | | |
Collapse
|
27
|
Goyal CR, Sharma NC, Qaqish JG, Cugini MA, Thompson MC, Warren PR. Efficacy of a novel brush head in the comparison of two power toothbrushes on removal of plaque and naturally occurring extrinsic stain. J Dent 2005; 33S1:37-43. [PMID: 16253754] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2023] Open
Abstract
OBJECTIVES.: To compare the safety and efficacy of an oscillating/pulsating power toothbrush (Oral-B ProfessionalCaretrade mark 7000; PC 7000) fitted with either the standard FlexiSoft (PC 7000/EB17) brush head or the novel Pro Polisher (PC 7000/EB-Prophy) and a high-frequency toothbrush (Philips Sonicare(R) Elite(R); SE), in their relative ability to remove plaque and naturally occurring extrinsic dental stain over a six-week period. METHODS.: This randomised, examiner-blind, parallel group study involved 90 healthy subjects from a general population. All subjects received a baseline plaque (Turesky et al. modified Quigley-Hein Plaque Index), stain (Lobene Stain Index) and tooth shade (VITAPAN(R) Shade Guide) [Vita] assessment and an oral tissue examination. After training in the use of their randomly assigned device, subjects were instructed to brush twice daily for 2 min and returned after 3, 4 and 6 weeks of product use for a repeat of each clinical assessment. RESULTS.: Reductions from baseline in mean plaque and extrinsic dental stain scores were significant at Weeks 3, 4 and 6 in all three treatment groups. By Week 6, mean reductions from baseline in whole mouth plaque scores were 32%, 27% and 14% in the PC 7000/EB-Prophy, PC 7000/EB17 and SE groups, respectively. For the body of the tooth, mean reductions from baseline at Week 6 in total stain were 89%, 89% and 80%, respectively. Between treatment group comparisons consistently revealed that the PC 7000 toothbrush plus the EB-Prophy or EB17 brush head removed significantly more plaque and extrinsic stain (total stain, stain area and stain intensity) than the SE toothbrush at 3, 4 and 6 weeks. The EB-Prophy group had a greater proportion of subjects showing a 2-3+ change in Vita shade scores at each time point compared to the other two brushes; at Week 6 the proportions were 67% in the PC 7000/EB-Prophy group, 30% in the PC 7000/EB17 group, and 7% in the SE group. The PC 7000/EB17, PC 7000/EB-Prophy and the SE were found to be safe as used in the study. CONCLUSIONS.: The oscillating/rotating/pulsating PC 7000 (fitted with either the standard EB17 or novel EB-Prophy brush head) is more effective at removal of plaque and naturally occurring extrinsic tooth stain, and the PC 7000 plus EB-Prophy in the improvement of tooth shade, than the high-frequency SE toothbrush.
Collapse
Affiliation(s)
- C R Goyal
- BioSci Research Canada Ltd., 6245 Mississauga Road, Mississauga, Ontario L5N 1A4, Canada
| | | | | | | | | | | |
Collapse
|
28
|
Sharma NC, Qaqish JG, Galustians HJ, Goyal CR, Cugini MA, Thompson MC, Warren PR. Plaque removal efficacy of two electric toothbrushes with different brush head designs. J Dent 2005; 33 Suppl 1:17-21. [PMID: 16208799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/04/2023] Open
Abstract
OBJECTIVES To compare the safety and plaque removal efficacy of two electric toothbrushes, one a rechargeable oscillating/pulsating toothbrush with a small round brush head (Oral-B ProfessionalCare 7000; PC 7000), the other a battery-operated toothbrush with a dual moving brush head (Crest SpinBrush Pro; SBP). METHODS The study had a randomised, examiner-blind, two-arm crossover design. All subjects received an oral prophylaxis and used both toothbrushes on alternating days for a two-week practice period. After abstaining from all oral hygiene procedures for 23-25 hours, subjects received an oral tissue examination and those with pre-brushing whole mouth mean plaque scores > or = 0.60 measured by the Rustogi et al. Modified Navy Plaque Index were randomly assigned to treatment sequence. Subjects brushed with their assigned toothbrush for 2 minutes using a commercially available dentifrice. Oral tissues were then re-examined and post-brushing plaque scores recorded. After a brief washout period, the above procedures were repeated with the alternate toothbrush. One examiner, blinded to the treatment sequence, performed all clinical measurements. RESULTS A total of 70 subjects (24 males and 46 females) were enrolled and completed the study. Each toothbrush was found to be safe and significantly reduced plaque levels after a single brushing. The PC 7000 was significantly more effective in plaque removal than the SBP at all tooth areas, reducing whole mouth plaque by 61% versus 58% and plaque from approximal surfaces by 69% versus 65%, respectively. CONCLUSIONS The action of the oscillating/pulsating toothbrush with a small round brush head, Oral-B ProfessionalCare 7000, is more effective in plaque removal than the battery-operated Crest SpinBrush Pro toothbrush with a larger dual moving brush head.
Collapse
Affiliation(s)
- N C Sharma
- BioSci Research Canada Ltd., 6245 Mississauga Road, Mississauga, Ontario L5N 1A4, Canada
| | | | | | | | | | | | | |
Collapse
|
29
|
Sharma NC, Qaqish JG, Galustians HJ, Cugini M, Thompson MC, Warren PR. Plaque removal efficacy and safety of the next generation of manual toothbrush with angled bristle technology: results from three comparative clinical studies. Am J Dent 2005; 18:3-7. [PMID: 15810473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
PURPOSE To investigate the safety and efficacy of a novel angled-bristled toothbrush in comparison with three established brushes. METHODS The Oral-B CrossAction Vitalizer toothbrush was compared with two manual toothbrushes, the Oral-B CrossAction and Oral-B Advantage, and the battery-operated Crest SpinBrush Pro brush in three independent single-use, examiner-blind, crossover studies. In each study, over 50 healthy subjects from a normal population brushed with their randomly assigned toothbrush for 1 minute without instruction. Subjects returned after a 1-week washout period and brushed with the alternate toothbrush. At each visit, oral hard and soft tissues and plaque were examined before and after brushing. Plaque was evaluated using the Rustogi Modified Navy Plaque Index. RESULTS Each tested toothbrush significantly (P=0.0001) reduced plaque levels after a single brushing. However, in all three studies, the CrossAction Vitalizer was significantly (P=0.0001) more effective than the comparator brushes in plaque removal from the whole mouth, the gingival margin and approximal surfaces. All toothbrushes were found to be safe with no evidence of oral hard or soft tissue trauma.
Collapse
Affiliation(s)
- Naresh C Sharma
- BioSci Research Canada, Ltd,Mississauga, Ontario L5N 1A4, Canada
| | | | | | | | | | | |
Collapse
|
30
|
Goyal CR, Qaqish JG, Sharma NC, Warren PR, Cugini M, Thompson MC. Plaque removal efficacy of a novel tooth wipe. J Clin Dent 2005; 16:44-6. [PMID: 16170975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
OBJECTIVE This study was designed to evaluate the safety and plaque removal efficacy of a tooth wipe (Oral-B Brush-Ups) using a manual toothbrush as a control. METHODOLOGY Twenty-five healthy subjects from a general population were enrolled in this randomized, single-use, crossover study. After 23-25 hours of no oral hygiene, oral hard and soft tissues were examined, and disclosed plaque was scored using the Turesky, et al. modification of the Quigley Hein Plaque Index. Subjects used their randomly assigned product for a timed period of one minute without instruction, after which hard and soft tissues and plaque scores were reassessed. Subjects returned to the clinic after a one-week washout period, and the clinical procedures were repeated before and after use of the alternate product. All clinical measurements were made by one examiner who was masked to treatment sequence. RESULTS Both the tooth wipe and toothbrush were found to be safe, and significantly reduced plaque levels from whole mouth, facial, and lingual surfaces (p < 0.0001). The toothbrush removed significantly greater plaque than the tooth wipe (p < 0.0001) on whole mouth surfaces (49% vs. 29%), facial surfaces (71% vs. 44%), and lingual surfaces (25% vs. 13%). CONCLUSION The tooth wipe provides an effective method of plaque removal when tooth brushing is not practical.
Collapse
Affiliation(s)
- C Ram Goyal
- BioSci Research Canada Ltd., Mississauga, Ontario, Canada
| | | | | | | | | | | |
Collapse
|
31
|
Sharma NC, Charles CH, Qaqish JG, Galustians HJ, Zhao Q, Kumar LD. Comparative effectiveness of an essential oil mouthrinse and dental floss in controlling interproximal gingivitis and plaque. Am J Dent 2002; 15:351-5. [PMID: 12691269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 03/01/2023]
Abstract
PURPOSE To compare the effectiveness of rinsing with an essential oil-containing antimicrobial mouthrinse with that of dental floss in reducing interproximal gingivitis and plaque in an unsupervised 6-month clinical trial designed in accordance with ADA Acceptance Program Guidelines. MATERIALS AND METHODS 319 qualifying subjects, aged 18-63, were randomized into one of three groups: essential oil mouthrinse (Listerine Antiseptic); dental floss (Reach Dental Floss); or a negative control rinse. At baseline, subjects received a complete oral soft tissue examination and scoring of the Modified Gingival Index (MGI), modified Quigley-Hein Plaque Index (PI), and bleeding index (BI). Following a complete dental prophylaxis and receiving flossing or rinsing instructions, subjects started on their respective regimen. They continued on their assigned regimen unsupervised at home, in addition to toothbrushing, and were reexamined at 3 and 6 months. The treatment groups were compared with respect to baseline demographic and clinical variables. The primary efficacy variables were mean interproximal MGI and PI at 6 months. Intergroup differences at 3 and 6 months were tested using a one-way analysis of covariance model with treatment as a factor and the respective baseline value as the covariate. In addition, the essential oil mouthrinse was compared to floss for interproximal gingivitis reduction using "at least as good as" statistical criteria. RESULTS 301 subjects were considered evaluable. There were no statistically significant differences among the 3 groups at baseline, with the exception of the essential oil mouthrinse group having significantly fewer AfroAmerican subjects than the other two groups. For the interproximal MGI, the essential oil mouthrinse and flossing were both significantly more effective than the negative control (P < 0.001) at 3 and 6 months. The essential oil mouthrinse was shown to be "at least as good as" dental floss for the control of interproximal gingivitis. For the interproximal PI, the essential oil mouthrinse was significantly more effective than the negative control at 3 and 6 months (P < 0.001) while flossing was significantly more effective than the negative control at 3 months (P < 0.05) but not at 6 months. The essential oil mouthrinse was significantly more effective than floss (P < 0.001) at both these time periods.
Collapse
|
32
|
Sharma N, Galustians HJ, Qaqish JG, Rustogi KN, Petrone ME, Volpe AR. Comparative efficacy on supragingival plaque and gingivitis of a manual toothbrush (Colgate Plus) and a battery-powered toothbrush (Colgate Actibrush) over a 30-day period. Compend Contin Educ Dent Suppl 2002:S9-13; quiz S34. [PMID: 11908375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
This clinical study compared the effect of Colgate Actibrush, a battery-powered toothbrush, and Colgate Plus Diamond Head, a full-head, soft-bristled manual toothbrush, on established supragingival plaque and gingivitis over a 30-day period. Sixty-two healthy adult men and women were entered in the study. The subjects were stratified into two balanced groups according to their mean baseline plaque and gingivitis scores. Each group was randomly assigned to the use of one of the two toothbrushes. Subjects were instructed to brush their teeth at home twice daily (morning and evening) for 1 minute with their assigned toothbrush and a commercially available tooth-paste for the 30-day duration of the study. Gingivitis and plaque examinations, as well as a soft-tissue evaluation, were conducted by the same dental examiner at baseline and after 15 and 30 days of toothbrush use. Plaque and gingivitis scores were reduced significantly from baseline after the use of both toothbrushes for 30 days. However, improvement in both supragingival plaque and gingivitis scores was significantly greater in the group using Colgate Actibrush. In conclusion, although both toothbrushes provided a significant plaque and gingivitis benefit when used as part of a normal oral hygiene regimen, the efficacy of the Colgate Actibrush was demonstrated to be superior to that of the Colgate Plus Toothbrush after 30 days of use.
Collapse
Affiliation(s)
- N Sharma
- BioSci Research Canada, Ltd, Mississauga, Ontario, Canada
| | | | | | | | | | | |
Collapse
|
33
|
Sharma NC, Galustians JH, Qaqish JG. An evaluation of a commercial chewing gum in combination with normal toothbrushing for reducing dental plaque and gingivitis. Compend Contin Educ Dent 2001; 22:13-7. [PMID: 11913304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
New evidence suggests a beneficial outcome to chewing a sugarless gum as an added component to a regular, twice-daily toothbrushing regimen. Results of a 4-week study performed on 78 adults with preexisting gingivitis showed a significant reduction of dental plaque and gingivitis when the test group of 39 adults chewed 2 pieces of ARM & HAMMER Dental Care The Baking Soda Gum (AHDC)--a sugar-free chewing gum containing sorbitol, malitol, xylitol, and sodium bicarbonate--for 20 minutes twice a day in conjunction with once-daily toothbrushing for 60 seconds. The control group, also comprised of 39 adults, used breath mints (the study placebo) twice a day in conjunction with the same toothbrushing regimen. There were no statistically significant differences in plaque and gingivitis scores at the baseline examination. Using the Quigley-Hein Plaque Index, the test group experienced a 17% reduction in plaque over 4 weeks, while the control group reduced their plaque amounts by approximately 9% over the same period. Lobene's Mean Gingivitis Index scores were equally significant: a nearly 10% decline for the test group compared to almost 2% for the control group. This article describes the 4-week study and its promising results.
Collapse
Affiliation(s)
- N C Sharma
- BioSci Research Canada, Ltd., Ontario, Canada
| | | | | |
Collapse
|
34
|
Sharma NC, Qaqish JG, Galustians HJ, King DW, Low MA, Jacobs DM, Weber DA. An advanced toothbrush with improved plaque removal efficacy. Am J Dent 2000; 13:15A-19A. [PMID: 11763939] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/23/2023]
Abstract
PURPOSE To compare the plaque removal efficacy and safety of a new advanced manual toothbrush, the Oral-B CrossAction, with seven other toothbrushes. MATERIALS AND METHODS Seven independent, cross-over design clinical studies were conducted using the same examiner who was blind to the identity of the test products and treatment assignments. In each study, approximately 75 healthy adult subjects from a general population brushed with their randomly assigned toothbrush (CrossAction or comparison brush) at Visit 1 for 1 min without supervision or instruction in brushing technique. Subjects returned after a 1-week washout period and brushed with the alternate toothbrush (Visit 2). Plaque was evaluated before and after brushing using the Rustogi Modified Navy Plaque Index. Statistical analyses were conducted by an independent statistician who remained blind to the identity of all test products. RESULTS Each of the toothbrushes tested provided significant (P < or = 0.0001) reductions in plaque scores after a single brushing. In each of the studies, the CrossAction toothbrush removed significantly (P < or = 0.0001) greater amounts of whole mouth, gingival margin, and approximal plaque than the compared toothbrush. All toothbrushes were found to be safe, with no changes in oral tissues or restorations observed over the course of each study. The results from these studies were consistent, demonstrating that the CrossAction toothbrush significantly enhances the ability of subjects to remove more plaque during normal brushing compared to seven other toothbrushes.
Collapse
Affiliation(s)
- N C Sharma
- BioSci Research Canada Ltd., Mississauga, Ontario
| | | | | | | | | | | | | |
Collapse
|
35
|
Sharma NC, Qaqish JG, Galustians HJ, King DW, Low MA, Jacobs DM, Weber DA. A 3-month comparative investigation of the safety and efficacy of a new toothbrush: results from two independent clinical studies. Am J Dent 2000; 13:27A-32A. [PMID: 11763941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/23/2023]
Abstract
PURPOSE To compare the efficacy of a new toothbrush featuring a novel brush head design with those of two established toothbrushes by measuring plaque and gingivitis over a period of 12 weeks. MATERIALS AND METHODS The Oral-B CrossAction toothbrush was compared with the Dr. Best InterDent and Crest DeepSweep toothbrushes in two independent, parallel-group, examiner-blind clinical studies. Each study involved approximately 100 healthy individuals from a general population. At baseline, after 23-25 hrs of no oral hygiene, oral hard and soft tissues were examined and whole mouth, marginal and approximal plaque scores and whole mouth gingivitis scores were recorded. Subjects in the two studies were asked to use their assigned toothbrush twice a day. No instruction in brushing technique or brushing time was given. After a period of 6 weeks and finally after 12 weeks, subjects in the studies were reassessed for oral tissue status, and their plaque and gingival indices were rescored. RESULTS In each of the two studies, the tested toothbrushes significantly reduced levels of plaque and gingivitis. The CrossAction toothbrush was, however, more effective in reducing both plaque and gingivitis over 12 weeks, the differences in favor of the CrossAction being statistically significant. All the toothbrushes tested in this investigation were found to be safe with no evidence of hard or soft tissue trauma.
Collapse
Affiliation(s)
- N C Sharma
- BioSci Research Canada, Ltd., Mississauga, Ontario.
| | | | | | | | | | | | | |
Collapse
|