1
|
Hansen V, Jensen J, Kusk MW, Gerke O, Tromborg HB, Lysdahlgaard S. Deep learning performance compared to healthcare experts in detecting wrist fractures from radiographs: A systematic review and meta-analysis. Eur J Radiol 2024; 174:111399. [PMID: 38428318 DOI: 10.1016/j.ejrad.2024.111399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 01/29/2024] [Accepted: 02/26/2024] [Indexed: 03/03/2024]
Abstract
OBJECTIVE To perform a systematic review and meta-analysis of the diagnostic accuracy of deep learning (DL) algorithms in the diagnosis of wrist fractures (WF) on plain wrist radiographs, taking healthcare experts consensus as reference standard. METHODS Embase, Medline, PubMed, Scopus and Web of Science were searched in the period from 1 Jan 2012 to 9 March 2023. Eligible studies were patients with wrist radiographs for radial and ulnar fractures as the target condition, studies using DL algorithms based on convolutional neural networks (CNN), and healthcare experts consensus as the minimum reference standard. Studies were assessed with a modified QUADAS-2 tool, and we applied a bivariate random-effects model for meta-analysis of diagnostic test accuracy data. RESULTS Our study was registered at PROSPERO with ID: CRD42023431398. We included 6 unique studies for meta-analysis, with a total of 33,026 radiographs. CNN performance compared to reference standards for the included articles found a summary sensitivity of 92% (95% CI: 80%-97%) and a summary specificity of 93% (95% CI: 76%-98%). The generalized bivariate I-squared statistic indicated considerable heterogeneity between the studies (81.90%). Four studies had one or more domains at high risk of bias and two studies had concerns regarding applicability. CONCLUSION The diagnostic accuracy of CNNs was comparable to that of healthcare experts in wrist radiographs for investigation of WF. There is a need for studies with a robust reference standard, external data-set validation and investigation of diagnostic performance of healthcare experts aided with CNNs. CLINICAL RELEVANCE STATEMENT DL matches healthcare experts in diagnosing WFs, which potentially benefits patient diagnosis.
Collapse
Affiliation(s)
- V Hansen
- Department of Radiology and Nuclear Medicine, Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark
| | - J Jensen
- Department of Radiology, Odense University Hospital, Odense, Denmark; Research and Innovation Unit of Radiology, University of Southern Denmark, Odense, Denmark
| | - M W Kusk
- Department of Radiology and Nuclear Medicine, Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark; Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark; Imaging Research Initiative Southwest (IRIS), Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark; Radiography and Diagnostic Imaging, School of Medicine, University College Dublin, Belfield 4, Dublin, Ireland
| | - O Gerke
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - H B Tromborg
- Department of Clinical Research, University of Southern Denmark, Odense, Denmark; Department of Orthopedic Surgery, Odense University Hospital, Odense, Denmark
| | - S Lysdahlgaard
- Department of Radiology and Nuclear Medicine, Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark; Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark; Imaging Research Initiative Southwest (IRIS), Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark.
| |
Collapse
|
2
|
Pedersen MRV, Kusk MW, Lysdahlgaard S, Mork-Knudsen H, Malamateniou C, Jensen J. Nordic radiographers' and students' perspectives on artificial intelligence - A cross-sectional online survey. Radiography (Lond) 2024; 30:776-783. [PMID: 38461583 DOI: 10.1016/j.radi.2024.02.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 01/17/2024] [Accepted: 02/26/2024] [Indexed: 03/12/2024]
Abstract
INTRODUCTION The integration of artificial intelligence (AI) into the domain of radiography holds substantial potential in various aspects including workflow efficiency, image processing, patient positioning, and quality assurance. The successful implementation of AI within a Radiology department necessitates the participation of key stakeholders, particularly radiographers. The study aimed to provide a comprehensive investigation about Nordic radiographers' perspectives and attitudes towards AI in radiography. METHODS An online 29-item survey was distributed via social media platforms to Nordic students and radiographers working in Denmark, Norway, Sweden, Iceland, Greenland, and the Faroe Islands including items on demographics, specialization, educational background, place of work and perspectives and knowledge on AI. The items were a mix of closed-type and scaled questions, with the option for free-text responses when relevant. RESULTS The survey received responses from all Nordic countries with 586 respondents, 26.8% males, 72.1% females, and 1.1% non-binary/self-defined or preferred not to say. The mean age was 37.2 with a standard deviation (SD) of ±12.1 years, and the mean number of years since qualification was 14.2 SD ± 10.3 years. A total of 43% (n = 254) of the respondents had not received any AI training in clinical practice. Whereas 13% (n = 76) had received AI during radiography undergrad training. A total of 77.9% (n = 412) expressed interest in pursuing AI education. The majority of respondents were aware of the potential use of AI (n = 485, 82.8%) and 39.1% (n = 204) had no reservations about AI. CONCLUSION Overall, this study found that Nordic radiographers have a positive attitude toward AI. Very limited training or education has been provided to the radiographers. Especially since 82.8% reports on plans to implement AI in clinical practice. In general, awareness of AI applications is high, but the educational level is low for Nordic radiographers. IMPLICATION FOR PRACTICE This study emphasises the favourable view of AI held by students and Nordic radiographers. However, there is a need for continuous professional development to facilitate the implementation and effective utilization of AI tools within the field of radiography.
Collapse
Affiliation(s)
- M R V Pedersen
- Department of Radiology, Vejle Hospital - Part of Lillebaelt Hospital, Vejle, Denmark; Department of Radiology, Kolding Hospital- Part of Lillebaelt Hospital, Kolding, Denmark; Department of Regional Health Research, University of Southern Denmark, Odense, Denmark; Discipline of Medical Imaging & Radiation Therapy, School of Medicine, University College Cork, Ireland.
| | - M W Kusk
- Department of Regional Health Research, University of Southern Denmark, Odense, Denmark; Department of Radiology and Nuclear Medicine, University Hospital of Southern Denmark, Esbjerg, Denmark; IRIS - Imaging Research Initiative Southwest, University Hospital of Southern Denmark, Esbjerg, Denmark; Radiography and Diagnostic Imaging, School of Medicine, University College Dublin, Dublin, Ireland
| | - S Lysdahlgaard
- Department of Regional Health Research, University of Southern Denmark, Odense, Denmark; Department of Radiology and Nuclear Medicine, University Hospital of Southern Denmark, Esbjerg, Denmark; IRIS - Imaging Research Initiative Southwest, University Hospital of Southern Denmark, Esbjerg, Denmark
| | - H Mork-Knudsen
- Department of Radiology, Haukeland University Hospital, Norway
| | - C Malamateniou
- Department of Radiography, Division of Midwifery and Radiography, School of Health and Psychological Sciences, City, University of London, UK; European Federation of Radiographer Societies, Churchilllaan 11, 3527 GV, Utrecht, the Netherlands
| | - J Jensen
- Research and Innovation Unit of Radiology, University of Southern Denmark, Odense, Denmark; Department of Radiology, Odense University Hospital, Odense, Denmark
| |
Collapse
|
3
|
de Chiffre JMD, Ormstrup TE, Kusk MW, Hess S. Patients from general practice with non-specific cancer symptoms: a retrospective study of symptoms and imaging. BJGP Open 2024:BJGPO.2023.0058. [PMID: 37604580 DOI: 10.3399/bjgpo.2023.0058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 07/10/2023] [Accepted: 07/23/2023] [Indexed: 08/23/2023] Open
Abstract
BACKGROUND Patients with non-specific symptoms or signs of cancer (NSSC) present a challenge as they are a heterogeneous population who are not candidates for fast-track work-up in an organ-specific cancer pre-planned pathway (CPP). Denmark has a cancer pre-planned pathway for this population (NSSC-CPP), but several issues remain unclarified, for example, distribution and significance of symptoms and findings, and choice of imaging. AIM To investigate symptoms, cancer diagnoses, and diagnostic yield of computed tomography (CT) and fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG-PET/CT) in patients on NSSC-CPP to improve the overall diagnostic process. DESIGN & SETTING A retrospective medical chart review in a 1-year consecutive cohort (2020). METHOD A total of 802 referrals were reviewed for diagnostic imaging in patients with NSSP from general practices, specialist practices, or the local hospital diagnostic centre responsible for NSSC-CPP. RESULTS The study included 248 patients; 21% had cancer, most frequently gastrointestinal cancer (27%). The most frequent symptom was weight loss (56%). CT had a sensitivity of 85%, specificity of 87%, positive predictive value (PPV) of 65%, and negative predictive value (NPV) of 96%. For 18F-FDG-PET/CT, the numbers were sensitivity 82%, specificity 62%, PPV 33%, and NPV 94%. Patients frequently underwent subsequent examinations following initial imaging. CONCLUSION The findings were in accordance with the literature. Patients with NSSC had a cancer prevalence of 21%, most frequently gastrointestinal. The most frequent symptom was weight loss and, even as the only symptom, it is a potential marker for cancer. CT and 18F-FDG-PET/CT were sensitive with high NPV, whereas PPV was superior in CT. Better stratification by symptoms or findings is an obvious focus point for future studies to further optimise the NSSC-CPP work-up strategy.
Collapse
Affiliation(s)
- Jonas Michele Dorph de Chiffre
- Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark
- Department of Radiology and Nuclear Medicine, University Hospital of Southern Denmark, Esbjerg, Denmark
| | - Tina Elisabeth Ormstrup
- Department of Radiology and Nuclear Medicine, University Hospital of Southern Denmark, Esbjerg, Denmark
| | - Martin Weber Kusk
- Department of Radiology and Nuclear Medicine, University Hospital of Southern Denmark, Esbjerg, Denmark
- IRIS - Imaging Research Initiative Southwest, University Hospital of Southern Denmark, Esbjerg, Denmark
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Dublin, Ireland
| | - Søren Hess
- Department of Radiology and Nuclear Medicine, University Hospital of Southern Denmark, Esbjerg, Denmark
- IRIS - Imaging Research Initiative Southwest, University Hospital of Southern Denmark, Esbjerg, Denmark
- Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark
| |
Collapse
|
4
|
Kusk MW, Hess S, Gerke O, Foley SJ. Potential for Dose Reduction in CT-Derived Left Ventricular Ejection Fraction: A Simulation Study. Tomography 2023; 9:2089-2102. [PMID: 37987350 PMCID: PMC10661257 DOI: 10.3390/tomography9060164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 11/13/2023] [Accepted: 11/13/2023] [Indexed: 11/22/2023] Open
Abstract
BACKGROUND Measuring left ventricular ejection fraction (LVEF) is important for detecting heart failure, e.g., in treatment with potentially cardiotoxic chemotherapy. MRI is considered the reference standard for LVEF, but availability may be limited and claustrophobia or metal implants still present challenges. CT has been shown to be accurate and would be advantageous, as LVEF could be measured in conjunction with routine chest-abdomen-pelvis oncology CT. However, the use of CT is not recommended due to the excessive radiation dose. This study aimed to explore the potential for dose reduction using simulation. Using an anthropomorphic heart phantom scanned at 13 dose levels, a noise simulation algorithm was developed to introduce controlled Poisson noise. Filtered backprojection parameters were iteratively tested to minimise differences in myocardium-to-ventricle contrast/noise ratio, as well as structural similarity index (SSIM) differences between real and simulated images at all dose levels. Fifty-one clinical CT coronary angiographies, scanned with full dose through end-systolic and -diastolic phases, were located retrospectively. Using the developed algorithm, noise was introduced corresponding to 25, 10, 5 and 2% of the original dose level. LVEF was measured using clinical software (Syngo.via VB50) with papillary muscles in and excluded from the LV volume. At each dose level, LVEF was compared to the 100% dose level, using Bland-Altman analysis. The effective dose was calculated from DLP using a conversion factor of 0.026 mSv/mGycm. RESULTS In the clinical images, mean CTDIvol and DLP were 47.1 mGy and 771.9 mGycm, respectively (effective dose 20.0 mSv). Measurements with papillary muscles excluded did not exhibit statistically significant LVEF bias to full-dose images at 25, 10 and 5% simulated dose. At 2% dose, a significant bias of 4.4% was found. With papillary muscles included, small but significant biases were found at all simulated dose levels. CONCLUSION Provided that measurements are performed with papillary muscles excluded from the LV volume, the dose can be reduced by a factor of 20 without significantly affecting LVEF measurements. This corresponds to an effective dose of 1 mSv. CT can potentially be used for LVEF measurement with minimal excessive radiation.
Collapse
Affiliation(s)
- Martin Weber Kusk
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Dublin 4 Belfield, Ireland;
- IRIS—Imaging Research Initiative Southwest, Department of Radiology & Nuclear Medicine, Esbjerg University Hospital, 6700 Esbjerg, Denmark;
- Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, 5230 Odense M, Denmark
| | - Søren Hess
- IRIS—Imaging Research Initiative Southwest, Department of Radiology & Nuclear Medicine, Esbjerg University Hospital, 6700 Esbjerg, Denmark;
- Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, 5230 Odense M, Denmark
- Department of Nuclear Medicine, Odense University Hospital, 5000 Odense, Denmark
| | - Oke Gerke
- Department of Nuclear Medicine, Odense University Hospital, 5000 Odense, Denmark
- Department of Clinical Research, University of Southern Denmark, 5000 Odense, Denmark
| | - Shane J. Foley
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Dublin 4 Belfield, Ireland;
| |
Collapse
|
5
|
Kusk MW, Bromark CS, Hestbek-Møller M, Davidsen LØ, Precht H, Brage K. Pill or pump? Nitroglycerin 0.5 mg tablet vs 0.8 mg spray: Effect on proximal vessel diameters at Coronary CT Angiography (CCTA). Radiography (Lond) 2023; 29:918-925. [PMID: 37478639 DOI: 10.1016/j.radi.2023.07.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 06/22/2023] [Accepted: 07/07/2023] [Indexed: 07/23/2023]
Abstract
INTRODUCTION The administration of sublingual Nitroglycerin (NTG) prior to CT coronary angiography (CCTA) can be perfomed using pump spray or tablets. Choice of method seems to be based on local preference, rather than published guidelines. This retrospective analysis tested whether proximal coronary diameters differed dependent on the sublingual administration of 0.5 mg Nitroglycerin (NTG) tablets or 0.8 mg NTG spray. METHODS 287 ECG-gated CCTA studies with optimal image quality and Agatston scores<400 were included in this retrospective analysis. 143 of the patients were dosed with NTG tablets at a dose of 0.5 mg prior to CCTA. 144 patients received 2 puffs of 0.4 mg NTG spray for a total dose of 8 mg. All were scanned on a second-generation Dual Source CT. Diameters of proximal segments of Left Main (LM), Right (RCA), Left Anterior (LAD) and circumflex (CX) coronary arteries were measured using semi-automatic electronic callipers by two blinded readers. Results were summarised as the mean of maximum and minimum diameters. Sex-specific analysis of diameters was carried out using repeated-measures ANOVA for each vessel. Agreement between readers was examined with Bland-Altman analysis and intra-class-correlation coefficient (ICC). RESULTS No significant differences in coronary diameters were found except in the RCA for women and LM for men. In both cases, diameters were smaller in the spray group (11 and 9%, respectively). Reader agreement was excellent, with ICC>0.96 for all vessels, and no significant bias, except in CX (0.03 mm). CONCLUSIONS We found no evidence for the systematic superiority of either administration method in proximal coronary vessels. IMPLICATIONS FOR PRACTICE Choosing between tablet or spray NTG prior to CCTA can be guided by practical, economical and hygienic considerations alone.
Collapse
Affiliation(s)
- M W Kusk
- Imaging Research Initiative SouthWest (IRIS), Esbjerg, Denmark; Department of Radiology and Nuclear Medicine, Esbjerg Hospital - University Hospital of Southern Denmark, Denmark; University College Dublin, School of Medicine, Dublin, Ireland; Institute of Regional Health Research, University of Southern Denmark, Odense, Denmark.
| | - C S Bromark
- Department of Radiology, Lillebaelt Hospital, University Hospitals of Southern Denmark, Kolding, Denmark
| | - M Hestbek-Møller
- Department of Radiology, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark
| | - L Ø Davidsen
- Department of Radiology, Odense University Hospital, Svendborg, Denmark
| | - H Precht
- Department of Radiology, Lillebaelt Hospital, University Hospitals of Southern Denmark, Kolding, Denmark; Health Sciences Research Centre, UCL University College, Odense, Denmark; Education of Radiography, UCL University College, Odense, Denmark; Institute of Regional Health Research, University of Southern Denmark, Odense, Denmark
| | - K Brage
- Education of Radiography, UCL University College, Odense, Denmark; Institute of Regional Health Research, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
6
|
Pedersen AE, Kusk MW, Knudsen GH, Busk CAGR, Lysdahlgaard S. Collimation border with U-Net segmentation on chest radiographs compared to radiologists. Radiography (Lond) 2023; 29:647-652. [PMID: 37141685 DOI: 10.1016/j.radi.2023.04.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 04/18/2023] [Accepted: 04/18/2023] [Indexed: 05/06/2023]
Abstract
INTRODUCTION Chest Radiography (CXR) is a common radiographic procedure. Radiation exposure to patients should be kept as low as reasonably achievable (ALARA), and monitored continuously as part of quality assurance (QA) programs. One of the most effective dose reduction tools is proper collimation practice. The purpose of this study is to determine whether a U-Net convolutional neural networks (U-CNN) can be trained to automatically segment the lungs and calculate an optimized collimation border on a limited CXR dataset. METHODS 662 CXRs with manual lung segmentations were obtained from an open-source dataset. These were used to train and validate three different U-CNNs for automatic lung segmentation and optimal collimation. The U-CNN dimensions were 128 × 128, 256 × 256, and 512 × 512 pixels and validated with five-fold cross validation. The U-CNN with the highest area under the curve (AUC) was tested externally, using a dataset of 50 CXRs. Dice scores (DS) were used to compare U-CNN segmentations with manual segmentations by three radiographers and two junior radiologists. RESULTS DS for the three U-CNN dimensions with segmentation of the lungs ranged from 0.93 to 0.96, respectively. DS of the collimation border for each U-CNN was 0.95 compared to the ground truth labels. DS for lung segmentation and collimation border between the junior radiologists was 0.97 and 0.97. One radiographer differed significantly from the U-CNN (p = 0.016). CONCLUSION We demonstrated that a U-CNN could reliably segment the lungs and suggest a collimation border with great accuracy compared to junior radiologists. This algorithm has the potential to automate collimation auditing of CXRs. IMPLICATIONS FOR PRACTICE Creating an automatic segmentation model of the lungs can produce a collimation border, which can be used in CXR QA programs.
Collapse
Affiliation(s)
- A E Pedersen
- Department of Radiology and Nuclear Medicine, Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark
| | - M W Kusk
- Department of Radiology and Nuclear Medicine, Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark; Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark; Imaging Research Initiative Southwest (IRIS), Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark; Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Ireland
| | - G H Knudsen
- Department of Radiology and Nuclear Medicine, Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark; Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark; Imaging Research Initiative Southwest (IRIS), Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark
| | - C A G R Busk
- Department of Radiology and Nuclear Medicine, Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark; Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark; Imaging Research Initiative Southwest (IRIS), Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark
| | - S Lysdahlgaard
- Department of Radiology and Nuclear Medicine, Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark; Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark; Imaging Research Initiative Southwest (IRIS), Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark.
| |
Collapse
|
7
|
Mørup SD, Stowe J, Precht H, Kusk MW, Lambrechtsen J, Foley SJ. COMBINING HI-RESOLUTION SCAN MODE WITH DEEP LEARNING RECONSTRUCTION ALGORITHMS IN CARDIAC CT. Radiat Prot Dosimetry 2023; 199:79-86. [PMID: 36420841 DOI: 10.1093/rpd/ncac243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/09/2022] [Revised: 10/22/2022] [Accepted: 10/31/2022] [Indexed: 06/16/2023]
Abstract
To investigate the impact of combining the high-resolution (Hi-res) scan mode with deep learning image reconstruction (DLIR) algorithm in CT. Two phantoms (Catphan600® and Lungman, small, medium, large size) were CT scanned using combinations of Hi-res/standard mode and high-definition (HD)/standard kernels. Images were reconstructed with ASiR-V and three levels of DLIR. Spatial resolution, noise and contrast-to-noise ratio (CNR) were assessed. The radiation dose was recorded. The spatial resolution increased using Hi-res & HD. Image noise in the Catphan600® (69%) and the Lungman (10-70%) significantly increased when Hi-res & HD was applied. DLIR reduced the mean noise (54%). The CNR was reduced (64%) for Hi-res & HD. The radiation dose increased for both small (+70%) and medium (+43%) Lungman phantoms but decreased slightly for the large ones (-3%) when Hi-res was applied. In conclusion, the Hi-res scan mode improved the spatial resolution. The HD kernel significantly increased the image noise. DLIR improved the image noise and CNR and did not affect the spatial resolution.
Collapse
Affiliation(s)
- Svea Deppe Mørup
- Health Sciences Research Centre, UCL University College, Niels Bohrs Alle 1, 5230 Odense M Denmark
- Cardiology Research Department, Odense University Hospital, Baagøes Alle 15, 5700 Svendborg, Denmark
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Belfield, Dublin 4, Ireland
| | - John Stowe
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Belfield, Dublin 4, Ireland
| | - Helle Precht
- Health Sciences Research Centre, UCL University College, Niels Bohrs Alle 1, 5230 Odense M Denmark
- Department of Regional Health Research, University of Southern Denmark, J.B. Winsløws Vej 19, 3, 5000 Odense C, Denmark
- Department of Radiology, Hospital Little Belt Kolding, Sygehusvej 24, 6000 Kolding, Denmark
| | - Martin Weber Kusk
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Belfield, Dublin 4, Ireland
- Department of Radiology and Nuclear Medicine, University Hospital of Southwest Jutland, Esbjerg, Denmark
| | - Jess Lambrechtsen
- Cardiology Research Department, Odense University Hospital, Baagøes Alle 15, 5700 Svendborg, Denmark
| | - Shane J Foley
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Belfield, Dublin 4, Ireland
| |
Collapse
|
8
|
Kusk MW, Lysdahlgaard S. The effect of Gaussian noise on pneumonia detection on chest radiographs, using convolutional neural networks. Radiography (Lond) 2023; 29:38-43. [PMID: 36274315 DOI: 10.1016/j.radi.2022.09.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 09/26/2022] [Accepted: 09/29/2022] [Indexed: 11/13/2022]
Abstract
INTRODUCTION Chest X-rays (CXR) with under-exposure increase image noise and this may affect convolutional neural network (CNN) performance. This study aimed to train and validate CNNs for classifying pneumonia on CXR as normal or pneumonia acquired at different image noise levels. METHODS The study used the curated and publicly available "Chest X-Ray Pneumonia" dataset of 5856 AP CXR classified into 1583 normal, 4273 viral and bacterial pneumonia cases. Gaussian noise with zero mean was added to the images, at 5 image noise variance levels, corresponding to decreasing exposure. Each noise-level dataset was split into 80% for training, 10% for validation, and 10% for test data and then classified using custom trained sequential CNN architecture. Six classification tasks were developed for five Gaussian noise levels and the original dataset. Sensitivity, specificity, predictive values and accuracy were used as evaluation performance metrics. RESULTS CNN evaluation on the different datasets revealed no performance drop from the original dataset to the five datasets with different noise levels. Sensitivity, specificity and accuracy for the normal datasets were 98.7%, 76.1% and 90.2%. For the five Gaussian noise levels the sensitivity, specificity and accuracy ranged from 96.9% to 98.2%, 94.4%-98.7% and 96.8%-97.6%, respectively. A heat map was used for visual explanation of the CNNs. CONCLUSION The CNNs sensitivity maintained, and the specificity increased in distinguishing between normal and pneumonia CXR with the introduction of image noise. IMPLICATIONS FOR PRACTICE No performance drops of CNNs in distinguishing cases with and without pneumonia CXR with different Gaussian noise levels was observed. This has potential for decreasing radiation dose to patients or maintaining exposure parameters for patients that require additional radiographs.
Collapse
Affiliation(s)
- M W Kusk
- Department of Radiology and Nuclear Medicine, Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark
| | - S Lysdahlgaard
- Department of Radiology and Nuclear Medicine, Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark; Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark; Imaging Research Initiative Southwest (IRIS), Hospital of South West Jutland, University Hospital of Southern Denmark, Esbjerg, Denmark.
| |
Collapse
|
9
|
Kusk MW, Stowe J, Hess S, Gerke O, Foley S. Low-cost 3D-printed anthropomorphic cardiac phantom, for computed tomography automatic left ventricle segmentation and volumetry - A pilot study. Radiography (Lond) 2023; 29:131-138. [PMID: 36368249 DOI: 10.1016/j.radi.2022.10.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 10/04/2022] [Accepted: 10/21/2022] [Indexed: 11/09/2022]
Abstract
INTRODUCTION Accurate cardiac left ventricle (LV) delineation is essential to CT-derived left ventricular ejection fraction (LVEF). To evaluate dose-reduction potential, an anatomically accurate heart phantom, with realistic X-ray attenuation is required. We demonstrated and tested a custom-made phantom using 3D-printing, and examined the influence of image noise on automatically measured LV volumes METHODS: A single coronary CT angiography (CCTA) dataset was segmented and converted to Standard Tessellation Language (STL) mesh, using open-source software. A 3D-printed model, with hollow left heart chambers, was printed and cavities filled with gelatinized contrast media. This was CT-scanned in an anthropomorphic chest phantom, at different exposure conditions. LV and "myocardium" noise and attenuation was measured. LV volume was automatically measured using two different methods. We calculated Spearmans' correlation of LV volume with noise and contrast-noise ratio respectively om 486 scans of the phantom. Source images were compared to one phantom series with similar parameters. This was done using Dice coefficient on LV short-axis segmentations. RESULTS Phantom "Myocardium" and LV attenuation was comparable to measurements on source images. Automatic volume measurement succeeded, with mean volume deviation to patient images less than 2 ml. There was a moderate correlation of volume with CNR, and strong correlation of volume with image noise. With papillary muscles included in LV volume, the correlation was positive, but negative when excluded. Variation of volumes was lowest at 90-100 kVp for both methods in the 486 repeat scans. The Dice coefficient was 0.87, indicating high overlap between the single phantom series and source scan. Cost of 3D-printer and materials was 400 and 30 Euro respectively. CONCLUSION Both anatomically and radiologically the phantom mimicked the source scans closely. LV volumetry was reliably performed with automatic algorithms. IMPLICATIONS FOR PRACTICE Patient-specific cardiac phantoms may be produced at minimal cost and can potentially be used for other anatomies and pathologies. This enables radiographic phantom studies without need for dedicated 3D-labs or expensive commercial phantoms.
Collapse
Affiliation(s)
- M W Kusk
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Ireland; Department of Radiology and Nuclear Medicine, University Hospital of Southern Denmark, Hospital South West Jutland Esbjerg, Denmark; IRIS - Imaging Research Initiative Southwest, Esbjerg, Denmark.
| | - J Stowe
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Ireland
| | - S Hess
- Department of Radiology and Nuclear Medicine, University Hospital of Southern Denmark, Hospital South West Jutland Esbjerg, Denmark; IRIS - Imaging Research Initiative Southwest, Esbjerg, Denmark; Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark
| | - O Gerke
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - S Foley
- Radiography & Diagnostic Imaging, School of Medicine, University College Dublin, Ireland
| |
Collapse
|
10
|
Elgaard PA, Simon L, Kusk MW. Collimation border with U-net segmentation on chest radiographs compared to radiologists. J Med Imaging Radiat Sci 2022. [DOI: 10.1016/j.jmir.2022.10.142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
|
11
|
Mørup SD, Stowe J, Kusk MW, Precht H, Foley S. The impact of ASiR-V on abdominal CT radiation dose and image quality – A phantom study. J Med Imaging Radiat Sci 2022; 53:453-459. [DOI: 10.1016/j.jmir.2022.06.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 06/21/2022] [Accepted: 06/22/2022] [Indexed: 11/29/2022]
|
12
|
Tækker Madsen K, Veien KT, Larsen P, Husain M, Deibjerg L, Junker A, Kusk MW, Thomsen KK, Rohold A, Jensen LO, Sand NPR. Coronary CT angiography-derived fractional flow reserve in-stable angina: association with recurrent chest pain. Eur Heart J Cardiovasc Imaging 2021; 23:1511-1519. [PMID: 34661645 PMCID: PMC9584620 DOI: 10.1093/ehjci/jeab198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Accepted: 09/19/2021] [Indexed: 01/09/2023] Open
Abstract
Aims The aim of this study was to evaluate the association between coronary computed tomography angiography (CCTA)-derived fractional flow reserve (FFRCT) and recurrent chest pain (CP) at 1-year follow-up in patients with stable angina pectoris (SAP). Methods and results Study of patients (n = 267) with SAP who underwent CCTA and FFRCT testing; 236 (88%) underwent invasive coronary angiography; and 87 (33%) were revascularized. Symptomatic status at 1-year follow-up was gathered by a structured interview. Three different FFRCT algorithms were applied using the following criteria for abnormality: (i) 2 cm-FFRCT ≤0.80; (ii) d-FFRCT ≤0.80; and (iii) a combination in which both a d-FFRCT ≤0.80 and a ΔFFRCT ≥0.06 must be present in the same vessel (c-FFRCT). Patients were classified into two groups based on the FFRCT test result and revascularization: completely revascularized/normal (CRN), patients in whom all coronary arteries with an abnormal FFRCT test result were revascularized or patients with completely normal FFRCT test results, and incompletely revascularized (IR), patients in whom ≥1 coronary artery with an abnormal FFRCT test result was not revascularized. Recurrent CP was present in 62 (23%) patients. Classification of patients (CRN or IR) was significantly associated with recurrent CP for all applied FFRCT interpretation algorithms. When applying the c-FFRCT algorithm, the association with recurrent CP was found, irrespective of the extent of coronary calcification and the degree of coronary stenosis. A negative association between per-patient minimal d-FFRCT and recurrent CP was demonstrated, P < 0.005. Conclusion An abnormal FFRCT test result is associated with an increased risk of recurrent CP in patients with new-onset SAP.
Collapse
Affiliation(s)
- Kristian Tækker Madsen
- Department of Cardiology, University Hospital of Southern Denmark, Finsensgade 35, Esbjerg DK-6700, Denmark
| | | | - Pia Larsen
- Department of Mental Health Services, Region of Southern Denmark, Odense, Denmark
| | - Majed Husain
- Department of Cardiology, University Hospital of Southern Denmark, Finsensgade 35, Esbjerg DK-6700, Denmark
| | - Lone Deibjerg
- Department of Cardiology, University Hospital of Southern Denmark, Finsensgade 35, Esbjerg DK-6700, Denmark
| | - Anders Junker
- Department of Cardiology, Odense University Hospital, Odense, Denmark
| | - Martin Weber Kusk
- Department of Radiology, University Hospital of Southern Denmark, Esbjerg, Denmark
| | - Kristian Korsgaard Thomsen
- Department of Cardiology, University Hospital of Southern Denmark, Finsensgade 35, Esbjerg DK-6700, Denmark
| | - Allan Rohold
- Department of Cardiology, University Hospital of Southern Denmark, Finsensgade 35, Esbjerg DK-6700, Denmark
| | | | - Niels Peter Rønnow Sand
- Department of Cardiology, University Hospital of Southern Denmark, Finsensgade 35, Esbjerg DK-6700, Denmark.,Department of Regional Health Research, University of Southern Denmark, Esbjerg, Denmark
| |
Collapse
|
13
|
Precht H, Outzen CB, Kusk MW, Bisgaard M, Waaler D. COMPARISON OF CONVENTIONAL HAND EXAMINATION ON SIX OPTIMISED DR SYSTEMS. Radiat Prot Dosimetry 2021; 194:27-35. [PMID: 33969425 PMCID: PMC8808537 DOI: 10.1093/rpd/ncab067] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 03/23/2021] [Accepted: 04/13/2021] [Indexed: 06/12/2023]
Abstract
The purpose of this study was to investigate the challenges in comparing digital radiography (DR) systems from different vendors for various combinations of exposure factors in posterior-anterior hand radiographs. Image quality was evaluated for a range of tube voltages and tube current-time products using a technical contrast-detail (CDRAD) phantom and an anthropomorphic hand phantom. 900 technical CDRAD images were analysed providing quality figures of merit (IQFinv) and two experienced reporting radiographers using visual grading analysis (VGA) scored 108 anthropomorphic images. This study demonstrates the differences between the DR systems included. When compensating for variations in dose, Canon showed superior results for technical image quality and Fuji for visual image quality for a standard dose point at DR hand examination (ln(DAP) 1.1, 50 kV and 2.5 mAs).
Collapse
Affiliation(s)
| | - Claus Bjørn Outzen
- Health Sciences Research Centre, UCL University College, Niels Bohrs Allé 1, 5230 Odense M, Denmark
| | - Martin Weber Kusk
- Department of Radiology and Nuclear Medicine, University Hospital of Southwest Denmark, Finsensgade 35, 6700 Esbjerg, Denmark
| | - Malene Bisgaard
- Health Sciences Research Centre, UCL University College, Niels Bohrs Allé 1, 5230 Odense M, Denmark
| | - Dag Waaler
- Department of Health Sciences, Gjøvik, Norwegian University of Science and Technology, Teknologiveien 22, 2803 Gjøvik, Norway
| |
Collapse
|
14
|
Shanmuganathan N, Ramanathan R, Dey D, Goeller M, Kusk MW, Sidelmann JJ, Norgaard BL, Gram JB, Sand NPR. Pericoronary adipose tissue attenuation in low-risk asymptomatic individuals, sex-differences and association with markers of cardiovascular disease. Eur J Prev Cardiol 2021. [DOI: 10.1093/eurjpc/zwab061.450] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Abstract
Funding Acknowledgements
Type of funding sources: None.
Introduction
Pericoronary adipose tissue (PCAT) attenuation by coronary computed tomography angiography (CCTA) is a marker of coronary inflammation and predicts clinical outcomes in symptomatic patients undergoing CCTA. Sex-differences in PCAT CT attenuation among asymptomatic individuals are not previously described.
Purpose
To evaluate PCAT CT attenuation according to sex and markers of cardiovascular disease (CVD).
Methods
Cross-sectional cohort study including asymptomatic individuals, 50- or 60-year of age, not taking any medicine and without known CVD or type-2 diabetes. At baseline and 5-year follow-up smoking habits, blood pressures and biochemistry (lipids, CRP, fibrinogen, D-dimer, t-PA, PAI-1, vWF) were recorded and Agatston Score measured. At follow-up, CCTA was achieved. Quantitative coronary plaque analysis was performed and PCAT CT attenuation within a radial distance of 3 mm from the outer vessel wall 10–50 mm distal to the origin of the right coronary artery measured. A validated PCAT CT attenuation threshold (high vs low risk) of -70.1 Hounsfield units was applied.
Results
Included were 123 participants (60 women). Independent of co-variation, PCAT CT attenuation (median, [IQR]) was lower in women (-71.0, [-77.2- -67.0]) vs men (-64.5, [-69.9- -57.4]), p < 0.001. No associations between PCAT CT attenuation (high vs low) and risk factors of CVD, CAC or coronary plaque volumes were demonstrated (Table). Variations in blood pressures, biochemical markers and CAC over five years were not associated with PCAT CT attenuation.
Conclusion
In low-risk asymptomatic individuals, PCAT CT attenuation was lower in women compared to men, irrespective of markers of CVD.
Table. Patient characteristics stratified by PCAT CT attenuation PCAT CT attenuation ≤ -70.1 HU (n = 49) PCAT CT attenuation > -70.1 HU (n = 74) p-value Risk factors Age65-years55-years 2623 3143 0.32 SexMenWomen 1534 4826 <0.001 TobaccoNeverCurrent/previous 1732 3737 0.10 Systolic BP, mmHgDiastolic BP, mmHgTotal cholesterol, mmol/lLDL-cholesterol, mmol/lHDL-cholesterol, mmol/lTriglycerides, mmol/l 137 (17)76 (10)5.61 (0.92)3.50 (0.93)1.41 (0.30)1.65 (0.99 - 2.22) 136 (16)77 (10)5.42 (0.82)3.30 (0.82)1.45 (0.35)1.35 (1.03 - 2.11) 0.660.590.230.220.570.52 Biochemistry CRP, mg/lFibrinogen, μmol/lD-dimer, mg/lvWFt-PAPAI-1 1.16 (0.99 - 2.22)9.5 (8.5 - 10.7)0.40 (0.30 - 0.49)128 (102 - 154)7.1 (5.8 - 8.8)20.5 (16.2 - 31.8) 0.61 (0.30 - 1.14)9.0 (7.8 - 10.0)0.32 (0.24 - 0.47)116 (92 - 146)6.3 (5.1 - 8.8)20.3 (14.7 - 26.3) <0.010.10<0.050.110.200.34 Coronary plaque data Agatston ScoreTotal plaque volume, mm³NCP volume, mm³CP volume, mm³LD-NCP volume, mm³ 1 (0 - 36)15.7 (0 - 143.3)0 (0 - 128.1)0 (0 - 14.6)0.5 (0 - 18.7) 8 (0 - 115)15.6 (0 - 268.2)13.5 (0 - 220.5)1.7 (0 - 31.7)1.8 (0 - 21.8) 0.300.450.490.360.74 Values are n (%), mean (SD) or median (IQR).Abbreviations: HU =Hounsfield unit; LDL =low-density lipoprotein; HDL =high-density lipoprotein; BP =blood pressure; CRP = c-reactive protein: vWF =von-Willebrand Factor; t-PA =tissue plasminogen activator; PAI-1 =plasminogen activator inhibitor -1; NCP =non-calcified plaque; CP =calcified plaque; LD-NCP =low-density non-calcified plaque.
Collapse
Affiliation(s)
- N Shanmuganathan
- University hospital of Southern Denmark, Department of Cardiology, Esbjerg, Denmark
| | - R Ramanathan
- University hospital of Southern Denmark, Department of Cardiology, Esbjerg, Denmark
| | - D Dey
- Cedars-Sinai Medical Center, Biomedical Imaging Research Institute, Los Angeles, United States of America
| | - M Goeller
- Friedrich Alexander University, Faculty of Medicine, Department of Cardiology, Erlangen, Germany
| | - MW Kusk
- University hospital of Southern Denmark, Department of Radiology, Esbjerg, Denmark
| | - JJ Sidelmann
- University of Southern Denmark, Department of Clinical Biochemistry and Unit for Thrombosis Research, Esbjerg, Denmark
| | - BL Norgaard
- Aarhus University Hospital, Department of Cardiology, Aarhus, Denmark
| | - JB Gram
- University of Southern Denmark, Department of Clinical Biochemistry and Unit for Thrombosis Research, Esbjerg, Denmark
| | - NPR Sand
- University of Southern Denmark, Department of Regional Health Research and Department of Cardiology, Esbjerg, Denmark
| |
Collapse
|
15
|
Kusk MW, Jensen JM, Gram EH, Nielsen J, Precht H. Anode heel effect: Does it impact image quality in digital radiography? A systematic literature review. Radiography (Lond) 2021; 27:976-981. [PMID: 33741222 DOI: 10.1016/j.radi.2021.02.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 02/25/2021] [Accepted: 02/26/2021] [Indexed: 01/28/2023]
Abstract
INTRODUCTION The anode heel effect can be used to optimize image quality and/or patient dose in digital radiography (DR). In film-screen radiography, the effect can equalize optical density in regions of varying attenuation. Clinical experience suggests that the implementation of DR has led to less awareness of anode orientation. Post-processing is assumed to compensate, but may also alter image impression and potentially obscure image details. Published evidence was examined for the influence of the anode heel effect on image quality in DR. METHOD A systematic literature search was carried out using PubMed, Embase, and Web of Science databases. Title and abstracts were screened blinded by three authors, according to in-/exclusion criteria, followed by full-text analysis for final inclusion. Studies where technical and/or visual image quality were reported, was included. All studies were analyzed and assigned quality scores, according to relevant questions. The authors devised a scoring system based on reported information pertaining to reproducibility, interpretation, and generalizability of the methods and conclusions. RESULTS Five studies were included of heterogeneous design, each with methodological shortcomings. Only a few anatomical areas were covered. Very few patients were examined, and in no studies were images evaluated by radiologists or reporting radiographers. Relevant information such as post-processing, image quality criteria and analysis was insufficient in most studies, making reproduction difficult. Results were contradictory, especially concerning technical vs visual image quality. CONCLUSION Limited published evidence was found quantifying the influence of the anode heel effect on image quality using DR technology. More methodologically, robust studies are needed. The published evidence neither proves nor disproves the impact of the heel effect on image quality in DR. IMPLICATIONS FOR PRACTICE Based on a systematic review, no firm recommendations for anode orientation relating to image quality in DR can be provided.
Collapse
Affiliation(s)
- M W Kusk
- Department of Radiology & Nuclear Medicine, Hospital of Southwest Jutland, University Hospital of Southern Denmark, Finsensgade 35, 6700 Esbjerg, Denmark.
| | - J M Jensen
- UCL University College, Niels Bohrs Allé 1, 5230 Odense M, Denmark.
| | - E H Gram
- Department of Radiology & Nuclear Medicine, Hospital of Southwest Jutland, University Hospital of Southern Denmark, Finsensgade 35, 6700 Esbjerg, Denmark; UCL University College, Niels Bohrs Allé 1, 5230 Odense M, Denmark.
| | - J Nielsen
- UCL University College, Niels Bohrs Allé 1, 5230 Odense M, Denmark.
| | - H Precht
- UCL University College, Niels Bohrs Allé 1, 5230 Odense M, Denmark; Department of Radiology, Lillebaelt Hospital, University Hospital of Southern Denmark, Sygehusvej 24, 6000 Kolding, Denmark; University of Southern Denmark, Department of Regional Health Research, Winsløwparken 19- 3, 5000 Odense C, Denmark.
| |
Collapse
|
16
|
Enevoldsen S, Kusk MW. Image quality of bedside chest radiographs in intensive care beds with integrated detector tray: A phantom study. Radiography (Lond) 2020; 27:453-458. [PMID: 33158751 DOI: 10.1016/j.radi.2020.10.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 10/18/2020] [Accepted: 10/19/2020] [Indexed: 10/23/2022]
Abstract
INTRODUCTION Vendors offer intensive care beds with integrated detector trays for bedside radiography, promoting better ergonomics and patient comfort. However, no documentation of the effects on diagnostic image quality has been located. This study examines measured and subjective image quality of supine bedside chest radiographs with and without use of such a detector tray. METHODS A contrast-detail phantom (CDRAD 2.0) was exposed using standard supine chest exposure parameters. Plexiglass plates of 16 and 21 cm were placed in front to simulate patient attenuation for standard and adipose patients. Exposures were repeated with the detector placed in tray and directly in bed. Images were analysed using dedicated software giving a figure-of-merit IQFinv. Results were compared using ANOVA. Then an anthropomorphic chest phantom (Lungman) was exposed using the same parameters, and the same placements of the detector. Exposures were done with and without extra conformal tissue to simulate varying patient sizes, and with and without added typical intensive care equipment. Images were analysed by two radiologists using a three-point scale, on five image quality criteria. Radiologist also stated whether the images were sufficient for diagnosis. Results were compared using Visual Grading Characteristics, using dedicated software, resulting in Areas Under the Curve (AUC-VGC) for each combination and criteria. Inter- and intra-rater reliability were assessed with kappa statistics. Composite Visual Grading Analysis (VGAS) scores were calculated for each image. Both IQFinv and were normalized and compared. RESULTS For all criteria both IQFinv and AUC-VGC was significantly better when exposing the detector directly in bed, than with the detector placed in the tray across all exposures. When stratified into thin and adipose patients, IQFinv decreased significantly for thin patients, while VGAS-scores did not. For adipose patients, both figures were significantly lower with the detector in the tray. CONCLUSION Use of detector tray for bedside chest imaging decreases image quality. IMPLICATIONS FOR PRACTICE Radiographers should critically evaluate image quality and experimentally determine optimal exposure factors, when taking equipment with integrated trays into use.
Collapse
Affiliation(s)
- S Enevoldsen
- University Hospital Southwest Denmark, Department of Radiology and Nuclear Medicine, Finsensgade 35, 6700 Esbjerg, Denmark.
| | - M W Kusk
- University Hospital Southwest Denmark, Department of Radiology and Nuclear Medicine, Finsensgade 35, 6700 Esbjerg, Denmark.
| |
Collapse
|
17
|
Lysdahlgaard S, Hess S, Gerke O, Weber Kusk M. A systematic literature review and meta-analysis of spectral CT compared to scintigraphy in the diagnosis of acute and chronic pulmonary embolisms. Eur Radiol 2020; 30:3624-3633. [PMID: 32112117 DOI: 10.1007/s00330-020-06735-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2019] [Revised: 12/20/2019] [Accepted: 02/07/2020] [Indexed: 01/26/2023]
Abstract
PURPOSE To examine the diagnostic accuracy of spectral CT pulmonary angiography (S-CTPA) using ventilation-perfusions lung scintigraphy (V/Q-scan) as a reference standard in the diagnosis of acute or chronic pulmonary embolism (APE/CPE) and chronic thromboembolic pulmonary hypertension (CTEPH). METHODS PubMed, Embase, Scopus, and Web of Science were searched for the period from 1 Jan 2006 to 7 Feb 2019; eligible studies had > 10 patients over 18 years old, a diagnostic outcome of PE or CTEPH, and used V/Q scan as a reference standard. Bias and applicability were assessed using QUADAS-2 tools. Sensitivities, specificities, and predictive values were noted or calculated from available information. Meta-analysis employed a fixed-effects model of Mantel and Haenszel. Heterogeneity was assessed with I-squared statistics. RESULTS Four hundred ninety-three unique records were identified. Following screening by title, 53 studies were included in the abstract and full-text assessment. A total of six articles were included; four were suitable for a meta-analysis. Pooled sensitivity was 94.2% (95% CI, 88.3-100%), pooled specificity was 88.5% (95% CI, 81.3-95.6%), and positive and negative predictive values were 87.8% (95% CI, 80.3-95.4%) and 94.5% (95% CI, 89.3-99.7%), respectively. CONCLUSION Data on S-CTPA for PE/CTEPH remains promising, but limited; only small studies with methodological issues are available. Evidence is best for CPE/CTEPH whereas no firm conclusions are possible for APE. There is a need for larger, prospective studies with a robust composite reference standard including state-of-the-art CTPA and V/Q-scans. KEY POINTS • S-CTPA has high sensitivity and specificity for perfusion defects in patients with PE or CPETH. • Methodological issues and diversity of reference standards were found in the small number of included studies. • There is a need for larger prospective studies with more robust composite reference standards.
Collapse
Affiliation(s)
- Simon Lysdahlgaard
- Department of Radiology and Nuclear Medicine, University Hospital of Southwest Jutland, Esbjerg, Denmark.
| | - Søren Hess
- Department of Radiology and Nuclear Medicine, University Hospital of Southwest Jutland, Esbjerg, Denmark
- Department of Regional Health Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark
| | - Oke Gerke
- Department of Nuclear Medicine, Odense University Hospital, Odense, Denmark
- Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, Odense, Denmark
| | - Martin Weber Kusk
- Department of Radiology and Nuclear Medicine, University Hospital of Southwest Jutland, Esbjerg, Denmark
| |
Collapse
|
18
|
Precht H, Mørup SD, Tingberg A, Outzen CB, Kusk KW, Nielsen RM, Midtgård M, Winther MB, Waaler D, Kusk MW. CAN SCATTER CORRECTION SOFTWARE REPLACE A GRID IN DR PELVIC EXAMINATIONS? Radiat Prot Dosimetry 2019; 187:8-16. [PMID: 31111927 DOI: 10.1093/rpd/ncz129] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2018] [Revised: 04/05/2019] [Accepted: 04/23/2019] [Indexed: 06/09/2023]
Abstract
The purpose was to examine if scatter correction software could replace a grid while maintaining image quality and reducing radiation dose for pelvic DR examinations. Grid images was produced with 70 kV and 16mAs. Anthropomorphic- and Contrast Detail RADiography (CDRAD) non-grid images were produced with 60 kV, 80 kV and 90 kV combined with five different mAs and scatter correction software. The anthropomorphic images were analyzed by absolute Visual Grading Analysis (VGA). The CDRAD images were analyzed using the CDRAD analysis software. The results showed a total of 54.6% non-grid images were evaluated as unsuitable for diagnostic use by the VGA. The CDRAD grid images showed that the IQF_inv values were significantly different (p = 0.0001) when compared to every group of non-grid images. Hereby, the conclusion stated that the scatter correction software did not compensate for the loss in image quality due to scattered radiation at the exposure levels included in a pelvic examination.
Collapse
Affiliation(s)
- Helle Precht
- Conrad Research Programme, University College Lillebelt, Niels Bohrs Alle 1, 5230 Odense M, Denmark
| | - Svea Deppe Mørup
- Conrad Research Programme, University College Lillebelt, Niels Bohrs Alle 1, 5230 Odense M, Denmark
| | - Anders Tingberg
- Medical Radiation Physics, Department of Clinical Sciences, Lund University, & Skåne University Hospital, 205 02 Malmö, Sweden
| | - Claus Bjørn Outzen
- Conrad Research Programme, University College Lillebelt, Niels Bohrs Alle 1, 5230 Odense M, Denmark
| | - Kirsten Weber Kusk
- Hospital of Southwest Denmark, SVS Esbjerg, Radiology department, Finsensgade 35, 6700 Esbjerg, Denmark
| | - Rita Møller Nielsen
- Hospital of Southwest Denmark, SVS Esbjerg, Radiology department, Finsensgade 35, 6700 Esbjerg, Denmark
| | - Marie Midtgård
- Lillebelt hospital, Radiology department, Skovvangen 2-8, 6000 Kolding, Denmark
| | | | - Dag Waaler
- Norwegian University of Science and Technology, Teknologiveien 22, 2803 Gjøvik, Norway
| | - Martin Weber Kusk
- Hospital of Southwest Denmark, SVS Esbjerg, Radiology department, Finsensgade 35, 6700 Esbjerg, Denmark
| |
Collapse
|
19
|
Madsen KT, Veien KT, Noergaard BL, Larsen P, Deibjerg L, Husain M, Junker A, Kusk MW, Thomsen KK, Rohold A, Jensen LO, Sand NP. P6175Prediction of coronary revascularization by coronary computed tomography angiography derived fractional flow reserve - different algorithms for interpretation. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz746.0781] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Introduction
Coronary CT angiography (CTA) derived fractional flow reserve (FFRct) is increasingly used for guiding referral to invasive procedures in patients with stable chest pain. However, optimal interpretation of FFRct-analysis in terms of location and threshold of applied FFRct-values is unclear.
Purpose
To evaluate the clinical performance of various vessel-specific physiological FFRct derived measures of ischemia for prediction of standard of care guided coronary revascularization in patients with stable chest pain and coronary artery disease as determined by coronary CTA.
Methods
Retrospective study in patients with stable chest pain referred for coronary angiography based on coronary CTA. Standard acquired coronary CTA data sets were transmitted for core-laboratory analysis at HeartFlow. Any FFRct value in the major coronary arteries ≥1.8 mm in diameter, including side branches, were registered. Lesions were categorized as positive for ischemia using 6 different algorithms: Lowest in vessel FFRct-value (1) ≤0.75 or (2) ≤0.80; 2 cm distal-to-lesion FFRct-value (3) ≤0.75 or (4) ≤0.80; ΔFFRct (5) ≥0.06 or a combination of 2 and 5. The personnel responsible for downstream patient management had no information regarding FFRct test results.
Results
A total of 172 patients were included. Revascularization was performed in 62 (35%) patients. The diagnostic performance of different FFRct algorithms for predicting standard of care guided coronary revascularization is shown in the Table.
Revascularization Predictions by FFRct N=172 Diagnostic performance FFRCT false negative FFRCT false positive Values given as (%) No. of revasc vessels No. of abnormal vessels FFRCT Algorithm Sens Spec PPV NPV Acc 1 2 3 1 2 3 Distal FFRCT ≤0.75 77 68 58 84 72 12 2 0 29 5 1 Distal FFRCT ≤0.80 92 43 48 90 61 5 0 0 40 20 3 Lesion-specific FFRCT ≤0.75 68 86 74 83 80 17 3 0 12 3 0 Lesion-specific FFRCT ≤0.80 82 78 68 89 80 10 2 0 21 3 1 ΔFFRCT ≥0.06 98 36 47 98 59 1 0 0 51 19 0 Combinationa 92 54 53 92 67 5 0 0 39 12 0 aDistal FFRCT ≤0.80 and ΔFFRCT ≥0.06. Sens = sensitivity; Spec = specificity; PPV = positive predictive value; NPV = negative predictive value; Acc = accuracy; FFRCT = fractional flow reserve derived from coronary CTA; ΔFFRCT = difference between FFRCT-value immediately proximal and distal to lesion; Revasc = revascularized.
Conclusion
The diagnostic performance of FFRct in terms of predicting standard of care guided coronary revascularization is dependent on the applied algorithm for interpretation of the FFRct-analysis.
Collapse
Affiliation(s)
- K T Madsen
- University Hospital of South West Jutland, Department of Cardiology, Esbjerg, Denmark
| | - K T Veien
- Odense University Hospital, Department of Cardiology, Odense, Denmark
| | - B L Noergaard
- Skejby University Hospital, Department of Cardiology, Aarhus, Denmark
| | - P Larsen
- University of Southern Denmark, Department of Epidemiology and Biostatistics, Odense, Denmark
| | - L Deibjerg
- University Hospital of South West Jutland, Department of Cardiology, Esbjerg, Denmark
| | - M Husain
- University Hospital of South West Jutland, Department of Cardiology, Esbjerg, Denmark
| | - A Junker
- Odense University Hospital, Department of Cardiology, Odense, Denmark
| | - M W Kusk
- University Hospital of South West Jutland, Department of Radiology, Esbjerg, Denmark
| | - K K Thomsen
- University Hospital of South West Jutland, Department of Cardiology, Esbjerg, Denmark
| | - A Rohold
- University Hospital of South West Jutland, Department of Cardiology, Esbjerg, Denmark
| | - L O Jensen
- Odense University Hospital, Department of Cardiology, Odense, Denmark
| | - N P Sand
- University Hospital of South West Jutland, Department of Cardiology, Esbjerg, Denmark
| |
Collapse
|
20
|
Madsen KT, Noergaard BL, Veien KT, Larsen P, Husain M, Deibjerg L, Junker A, Kusk MW, Thomsen KK, Rohold A, Jensen LO, Sand NP. P6186Symptomatic effect of coronary revascularization at 1-year follow-up in stable chest pain - prediction by coronary computed tomography angiography derived fractional flow reserve. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz746.0792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Introduction
Coronary CT angiography (CTA) derived fractional flow reserve (FFRct) is increasingly being used for guiding referral to invasive procedures in patients with stable chest pain. However, the ability of FFRct to predict the symptomatic effect of revascularization remains unclear.
Purpose
To evaluate the ability of different vessel-specific physiological FFRct derived measures of ischemia for predicting the occurrence of chest pain one year after coronary revascularization in stable patients.
Methods
Retrospective study in patients with stable chest pain referred for coronary angiography based on coronary CTA. Standard acquired coronary CTA data sets were transmitted for core-laboratory analysis at HeartFlow. Patients were categorized as positive for ischemia using 3 different algorithms: Lowest in vessel FFRct-value ≤0.80; ΔFFRct ≥0.06 or a combination of the two. Personnel responsible for downstream patient management had no information on FFRct test results. Classification of revascularization was performed based on the applied FFRct algorithm: complete if all FFRct positive lesions were revascularized; incomplete if ≥1 FFRct positive lesion was not revascularized. Symptomatic status at 1-year follow-up was obtained by a visit in the outpatient clinic or by telephone.
Results
A total of 172 patients were included. Revascularization was performed in 62 (35%) patients. At 1-year follow-up 48 (28%) patients had chest pain; 15 (24%) revascularized vs 33 (30%) non-vascularized patients, p=0.415. No difference in utilization of anti-anginal medicine for patients with and without chest pain was registered at 1-year follow-up. The association between the chosen FFRct algorithm, revascularization and occurrence of chest pain at 1-year follow-up are shown in the Table.
FFRct, Revascularization and Chest pain FFRCT, Algorithm Revascularizationb Patients with chest pain 1-year risk of chest pain p-valuec N (%) OR (95%-CI) Distal FFRCT ≤0.80 Incomplete 32 (34) Ref. Distal FFRCT ≤0.80 Complete 4 (15) 0.34 (0.11, 1.06) Distal FFRCT >0.80 No 11 (24) 0.61 (0.27, 1.35) 0.097 ΔFFRCT ≥0.06 Incomplete 34 (35) Ref. ΔFFRCT ≥0.06 Complete 7 (21) 0.49 (0.19, 1.24) ΔFFRCT <0.06 No 7 (18) 0.41 (0.16, 1.03) 0.074 Combinationa abnormal Incomplete 30 (40) Ref. Combination abnormal Complete 6 (18) 0.32 (0.12, 0.87) Combination normal No 11 (19) 0.35 (0.16, 0.78) 0.009 aDistal FFRCT ≤0.80 and ΔFFRCT ≥0.06. bIncomplete (≥1 FFRCT positive lesion not revascularized); complete (All FFRCT positive lesions revascularized); No (No FFRCT positive lesions and revascularization not performed). cBetween group comparison performed using logistic regression.
Conclusion
Revascularization based on classification by FFRct is associated with symptomatic relief at 1-year follow-up in patients with stable chest pain.
Collapse
Affiliation(s)
- K T Madsen
- University Hospital of South West Jutland, Department of Cardiology, Esbjerg, Denmark
| | - B L Noergaard
- Skejby University Hospital, Department of Cardiology, Aarhus, Denmark
| | - K T Veien
- Odense University Hospital, Department of Cardiology, Odense, Denmark
| | - P Larsen
- University of Southern Denmark, Department of Epidemiology and Biostatistics, Odense, Denmark
| | - M Husain
- University Hospital of South West Jutland, Department of Cardiology, Esbjerg, Denmark
| | - L Deibjerg
- University Hospital of South West Jutland, Department of Cardiology, Esbjerg, Denmark
| | - A Junker
- Odense University Hospital, Department of Cardiology, Odense, Denmark
| | - M W Kusk
- University Hospital of South West Jutland, Department of Radiology, Esbjerg, Denmark
| | - K K Thomsen
- University Hospital of South West Jutland, Department of Cardiology, Esbjerg, Denmark
| | - A Rohold
- University Hospital of South West Jutland, Department of Cardiology, Esbjerg, Denmark
| | - L O Jensen
- Odense University Hospital, Department of Cardiology, Odense, Denmark
| | - N P Sand
- University Hospital of South West Jutland, Department of Cardiology, Esbjerg, Denmark
| |
Collapse
|
21
|
Kusk MW. Artefact or hip prosthetic fracture on multislice CT? The importance of correct positioning when scanning metal implants. Radiography (Lond) 2019; 25:e75-e77. [PMID: 31301795 DOI: 10.1016/j.radi.2018.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Revised: 11/27/2018] [Accepted: 12/03/2018] [Indexed: 11/16/2022]
Affiliation(s)
- M W Kusk
- Hospital of Southwest Jutland, Department of Radiology and Nuclear Medicine, Finsensgade 35, 6700 Esbjerg, Denmark.
| |
Collapse
|
22
|
Kusk MW, Karstoft J, Mussmann BR. CT triage for lung malignancy: coronal multiplanar reformation versus images in three orthogonal planes. Acta Radiol 2015; 56:1336-41. [PMID: 25406433 DOI: 10.1177/0284185114556928] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2014] [Accepted: 09/29/2014] [Indexed: 11/15/2022]
Abstract
BACKGROUND Generation of multiplanar reformation (MPR) images has become automatic on most modern computed tomography (CT) scanners, potentially increasing the workload of the reporting radiologists. It is not always clear if this increases diagnostic performance in all clinical tasks. PURPOSE To assess detection performance using only coronal multiplanar reformations (MPR) when triaging patients for lung malignancies with CT compared to images in three orthogonal planes, and to evaluate performance comparison of novice and experienced readers. MATERIAL AND METHODS Retrospective study of 63 patients with suspicion of lung cancer, scanned on 64-slice multidetector computed tomography (MDCT) with images reconstructed in three planes. Coronal images were presented to four readers, two novice and two experienced. Readers decided whether the patients were suspicious for malignant disease, and indicated their confidence on a five-point scale. Sensitivity and specificity on per-patient basis was calculated with regards to a reference standard of histological diagnosis, and compared with the original report using McNemar's test. Receiver operating characteristic (ROC) curves were plotted to compare the performance of the four readers, using the area under the curve (AUC) as figure of merit. RESULTS No statistically significant difference of sensitivity and specificity was found for any of the readers when compared to the original reports. ROC analysis yielded AUCs in the range of 0.92-0.93 for all readers with no significant difference. Inter-rater agreement was substantial (kappa = 0.72). CONCLUSION Sensitivity and specificity were comparable to diagnosis using images in three planes. No significant difference was found between experienced and novice readers.
Collapse
Affiliation(s)
- Martin Weber Kusk
- Department of Radiology, Hospital of South West Jutland, Esbjerg, Denmark
| | - Jens Karstoft
- Department of Radiology, Odense University Hospital, Odense, Denmark
| | | |
Collapse
|