1
|
Jradi H, Wewers ME, Pirie PR, Binkley PF, Ferketich K. Cigarette and waterpipe smoking associated knowledge and behaviour among medical students in Lebanon. East Mediterr Health J 2013; 19:861-868. [PMID: 24313150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
As future physicians capable of controlling tobacco dependence in the population, medical students are considered a main target for tobacco control interventions. This cross-sectional study reported on the prevalence of tobacco use (cigarettes and waterpipes) and associated knowledge and behaviour among 6th-year medical students in 2009-2010 from 6 medical schools in Lebanon. The self-administered questionnaire based on the Global Health Professional Survey (GHPSS) core questions also enquired about training in tobacco cessation approaches. All enrolled students were asked to participate; the response rate was 191/354 (54.3%). The prevalence of tobacco use was 26.3% for cigarettes and 29.5% for waterpipes. Smoking waterpipes was the only significant predictor for cigarette smoking and there was no difference by sex and socioeconomic status. A minority reported ever receiving any formal training in treatment approaches for tobacco dependence. Medical schools should include tobacco dependence treatment training programmes in their curriculum and discourage tobacco use.
Collapse
Affiliation(s)
- H Jradi
- College of Public Health and Health Informatics, King Saud Bin Abdulaziz University for Health Sciences, National Guard Health Affairs, King Abdulaziz Medical City, Riyadh, Saudi Arabia.
| | | | | | | | | |
Collapse
|
2
|
|
3
|
Armstrong AT, Binkley PF, Baker PB, Leier CV. Histologic compaison of allograft myocardium between short- and long-term survivors of human cardiac transplantation. Am J Cardiol 2000; 86:1148-51, A9. [PMID: 11074219 DOI: 10.1016/s0002-9149(00)01179-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Myocardial histology of cardiac allografts differed between short-term (<5 years) and long-term (>5 years) survivors after transplantation. These differences may partially be attributable to a higher prevalence of systemic hypertension and allograft rejection in the short-term survivors, affecting hemodynamics and allograft function.
Collapse
Affiliation(s)
- A T Armstrong
- Department of Pathology, The Ohio State University College of Medicine, Columbus, USA
| | | | | | | |
Collapse
|
4
|
Abstract
Congestive heart failure (CHF), one of the few cardiovascular conditions increasing in incidence and prevalence, is characterized by high morbidity and mortality. Up to 50% of the mortality is attributable to dysrhythmic sudden death. Risk stratification to identify those most susceptible to sudden death remains imperfect. The advances in CHF therapeutics and management over the past 16 years have had a favorable impact on CHF mortality including sudden death. The role of amiodarone and implantable cardioverter-defibrillator intervention is evolving and discussed in the context of current CHF management and available trials.
Collapse
Affiliation(s)
- C V Leier
- Division of Cardiology, The Ohio State University Medical Center, Columbus, Ohio 43210, USA.
| | | | | |
Collapse
|
5
|
Cooke GE, Eaton GM, Whitby G, Kennedy RA, Binkley PF, Moeschberger ML, Leier CV. Plasma atherogenic markers in congestive heart failure and posttransplant (heart) patients. J Am Coll Cardiol 2000; 36:509-16. [PMID: 10933365 DOI: 10.1016/s0735-1097(00)00756-7] [Citation(s) in RCA: 43] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
OBJECTIVES We hypothesized that plasma factors important for the development of atherosclerosis play a major role in the occurrence of cardiac allograft vasculopathy (CAV). BACKGROUND Cardiac allograft vasculopathy is a major cause of death among heart transplant recipients, has a poorly understood pathogenesis and has similarities to atherosclerotic coronary disease. METHODS The study population consisted of 93 postcardiac transplant recipients. Thirty-one patients with congestive heart failure (CHF) and 18 healthy individuals served as control subjects. Posttransplant coronary anatomy was evaluated by angiography and intravascular ultrasound. Laboratory analyses of lipids, homocysteine, vitamin B12 and folate, fibrinogen, von Willebrand factor antigen (vWFAg) and renin were obtained on all participants. RESULTS Posttransplant patients were found to have elevated serum triglycerides, total cholesterol/ high-density lipoprotein cholesterol ratio, lipoprotein (a), homocysteine, vWFAg, fibrinogen and renin and lower high-density lipoprotein cholesterol. Most of these laboratory atherogenic factors were also elevated to a similar degree in the CHF control population. Although most atherogenic markers were elevated, there was little correlation with CAV severity. Cardiac allograft vasculopathy severity varied with time after transplantation, 3-hydroxy-methyl-glutaryl-coenzyme A reductase inhibitor use and prior cytomegalovirus infection. Even within the normal range, lower RBC folate levels were associated with increased severity of CAV. CONCLUSIONS The posttransplant course is associated with increased clinical and laboratory atherogenic factors, some of which likely contribute to the severity of coronary vasculopathy. Compared with normal control subjects, many of these markers are already increased in pretransplant CHF patients with or without occlusive coronary artery disease.
Collapse
Affiliation(s)
- G E Cooke
- The Heart and Lung Institute, Department of Internal Medicine, College of Medicine and Public Health, The Ohio State University, Columbus 43210, USA
| | | | | | | | | | | | | |
Collapse
|
6
|
Binkley PF, Nunziata E, Haas GJ, Starling RC, Leier CV, Cody RJ. Dissociation between ACE activity and autonomic response to ACE inhibition in patients with heart failure. Am Heart J 2000; 140:34-42. [PMID: 10874261 DOI: 10.1067/mhj.2000.107180] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
BACKGROUND Administration of angiotensin-converting enzyme (ACE) inhibitors to patients with congestive heart failure has been shown to increase parasympathetic tone as indicated by increases in high-frequency heart rate variability. The mechanism for this effect, including its relation to changes in baroreflex activity, blood pressure variability, and suppression of ACE activity, remains undefined. This study was designed to test the relation of these variables, which may govern changes in autonomic activity, to the previously described increase in parasympathetic tone. METHODS Seven patients with heart failure received a 3-hour infusion of the ACE inhibitor enalaprilat. Hemodynamic variables and parameters of heart rate and blood pressure variability, baroreflex gain derived from the interaction of heart rate and blood pressure variability, and serum ACE activity were measured during and after the infusion. Measures of heart rate and blood pressure variability were also compared against a historic control group. RESULTS Serum ACE activity was significantly suppressed throughout and after enalaprilat infusion. Hemodynamic measures did not change other than a small decline in right atrial and pulmonary capillary wedge pressures. Parasympathetic tone showed an initial significant increase with a peak at 2 hours but then declined below baseline 8 hours after initiation of enalaprilat infusion. Sympathetically influenced low-frequency heart rate variability was significantly increased above baseline in the enalaprilat treatment group 8 hours after initiation of the infusion. Baroreflex gain showed a significant trend to an increase with the maximum value coinciding with the peak in parasympathetic tone. There was no change in blood pressure variability in the enalaprilat group and no change in baroreflex gain, heart rate variability, or blood pressure variability in the control group. CONCLUSIONS Parasympathetic tone and baroreflex gain increased with parenteral administration of an ACE inhibitor but subsequently decreased below baseline values despite continued suppression of serum ACE activity. The dissociation between ACE suppression and autonomic response to ACE inhibition indicates that enzyme systems not reflected by plasma ACE activity or independent from the classic pathways of angiotensin formation contribute to the regulation of the autonomic response to ACE inhibition in patients with heart failure. The absence of significant change in hemodynamic variables or in blood pressure variability indicates that these autonomic changes are not an indirect reflex response to ACE inhibitor-induced vasodilation or hemodynamic baroreceptor stimulation.
Collapse
|
7
|
|
8
|
Abstract
Parenterally administered positive inotropic agents remain an important component of the therapeutics of cardiac dysfunction and failure. Dobutamine, a catechol, remains the prototype of this drug group, but recently has been joined by the phosphodiesterase III inhibitor, milrinone. Compared with dobutamine, milrinone has greater vasodilating-unloading properties. The catecholamine, dopamine, is often used as a parenteral positive inotrope; but at moderate to high dose, it evokes considerable systemic vasoconstriction. At lower doses, dopamine appears to augment renal function. Levosimendan and toborinone, new compounds with several mechanisms of action, are under active clinical investigation and review for approval. Parenteral positive inotropic therapy is indicated for short-term (hours to days) treatment of cardiovascular decompensation secondary to ventricular systolic dysfunction, low-output heart failure. More prolonged or continuous infusion of one of these agents may be necessary as a "pharmacologic bridge" to cardiac transplantation, another definitive intervention, or more advanced, intense medical therapy. An occasional patient will require a continuous infusion via indwelling venous catheter and portable pump, simply to be able to be discharged from the hospital setting and function in the home environment. Intermittent parenteral inotropic therapy for chronic heart failure has provoked considerable controversy and passion among cardiologists and heart failure specialists; an attempt is made to present this topic in an objective manner.
Collapse
Affiliation(s)
- C V Leier
- Division of Cardiology, The Ohio State University, College of Medicine and Public Health, Columbus, OH 43210, USA
| | | |
Collapse
|
9
|
Armstrong AT, Binkley PF, Baker PB, Myerowitz PD, Leier CV. Quantitative investigation of cardiomyocyte hypertrophy and myocardial fibrosis over 6 years after cardiac transplantation. J Am Coll Cardiol 1998; 32:704-10. [PMID: 9741515 DOI: 10.1016/s0735-1097(98)00296-4] [Citation(s) in RCA: 83] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
OBJECTIVES This study was performed to determine the degree and time course over 6 years of cardiomyocyte hypertrophy and myocardial fibrosis of the cardiac allograft in transplanted patients. BACKGROUND Diastolic dysfunction and to a certain extent systolic dysfunction are common cardiac findings after heart transplantation. The development of posttransplant cardiomyocyte hypertrophy and myocardial fibrosis likely contributes to these derangements. METHODS Cardiomyocyte diameter and percent fibrosis were determined in serial endomyocardial biopsy specimens obtained from 1 month up to 6 years following heart transplantation in 50 patients. Endomyocardial biopsy specimens from 40 patients with primary dilated cardiomyopathy and 11 normal subjects were similarly analyzed for control data. Analyses were performed in a blinded format using a validated computerized image analysis system (Optimas 5.2). RESULTS Early (1 month) cardiomyocyte enlargement decreased to the smallest diameter 6 months posttransplant, but thereafter progressively increased by 10% to 20% over the subsequent 5- to 6-year period. Although not statistically established, principal stimuli may include a discrepancy in body size (recipient > donor), coronary allograft vasculopathy and posttransplant systemic hypertension. Percent myocardial fibrosis rose early (1 to 2 months) posttransplant and thereafter remained at the same modest level of severity. CONCLUSIONS Cardiomyocyte diameter of the transplanted heart gradually increases over time, while percent myocardial fibrosis rises early and remains in a modestly elevated plateau after 2 months posttransplant. These histostructural changes likely contribute to the hemodynamic and cardiac functional alterations commonly observed posttransplant.
Collapse
Affiliation(s)
- A T Armstrong
- Division of Cardiology, The Ohio State University College of Medicine, Columbus, USA
| | | | | | | | | |
Collapse
|
10
|
Abstract
METHODS AND RESULTS Over an 18-month period, the patients on the heart transplantation waiting list at our institution were evaluated to determine if continued listing was appropriate. Ten patients were removed because of significant improvement in clinical status and exercise capacity (n = 9) or because of criteria violation (n = 1). Four of these patients died suddenly and unexpectedly within 4 months of delisting, resulting in a 6-month survival of 60% for the patients removed. During the same period, the 6-month survival for newly listed patients (n = 10) was 80% and that for newly transplanted patients (n = 13) was 92%. An elevated pulmonary capillary wedge pressure (> or = 18 mmHg) was the only clinical or laboratory feature that appeared to distinguish the four patients who died suddenly following delisting. CONCLUSION The results of this preliminary study suggest that removal of a patient from a heart transplant waiting list may represent a risk for sudden death, particularly in patients with elevated ventricular filling pressures, irrespective of otherwise favorable clinical status and exercise performance.
Collapse
Affiliation(s)
- C V Leier
- Division of Cardiology, Ohio, State University College of Medicine, Columbus, USA
| | | | | | | |
Collapse
|
11
|
Binkley PF, Van Fossen DB, Haas GJ, Leier CV. Increased ventricular contractility is not sufficient for effective positive inotropic intervention. Am J Physiol 1996; 271:H1635-42. [PMID: 8897961 DOI: 10.1152/ajpheart.1996.271.4.h1635] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Positive inotropic intervention with dobutamine in patients with congestive heart failure is accompanied by complementary vascular changes, as measured by the aortic input impedance spectrum, that promote the efficient transfer of augmented myocardial contractile power. It is unknown whether this is a nonspecific response to increased ventricular contractility or is a function of the properties of the positive inotropic agent employed. Therefore, the influence of two different positive inotropic interventions, dobutamine and dopamine, on ventricular-vascular coupling was examined in 15 patients with congestive heart failure. Significant reductions in characteristic aortic impedance, wave reflection, and low-frequency impedance moduli were noted with dobutamine and were not seen with dopamine. Consequently, a significantly (P = 0.0008) greater increase in pulsatile, rather than steady-state, power output was noted with dopamine that was reflective of a significantly diminished efficiency of power transfer. Therefore, optimal transfer of increased ventricular contractile power in patients with congestive heart failure requires increases in large vessel compliance and complementary changes in ventriculoarterial coupling.
Collapse
Affiliation(s)
- P F Binkley
- Department of Medicine, Ohio State University, Columbus 43210, USA
| | | | | | | |
Collapse
|
12
|
Tice FD, Peterson JW, Orsinelli DA, Binkley PF, Cody RJ, Guthrie R, Pearson AC. Vascular hypertrophy is an early finding in essential hypertension and is related to arterial pressure waveform contour. Am Heart J 1996; 132:621-7. [PMID: 8800034 DOI: 10.1016/s0002-8703(96)90247-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
The effects of hypertension on the arterial vasculature were examined in a study group of 20 patients with newly diagnosed essential hypertension, 18 patients with chronic essential hypertension, and 32 control subjects with normal blood pressure. Left ventricular mass was determined echocardiographically. Carotid artery intimal-medial thickness was measured by means of B-mode ultrasound imaging, and carotid arterial waveforms were obtained by applanation tonometry. Compared with that in control subjects, carotid intimal-medial thickness was increased in patients with chronic hypertension (0.74 +/- 0.17 mm vs 0.61 +/- 0.15 mm in control subjects; p < 0.01) and in patients with newly diagnosed hypertension (0.66 +/- 0.12 mm vs 0.61 +/- 0.15 mm in control subjects; p < 0.05). Left ventricular mass was also higher in patients with chronic hypertension than in control subjects but was very similar between control subjects and those with newly diagnosed hypertension. Both the group with early hypertension and the group with chronic hypertension had an increased incidence of early waveform reflection evident on carotid arterial waveform examination. By multiple regression analysis, independent predictors of increased carotid intimal-medial thickness were age, systolic arterial pressure, and Murgo class of arterial waveform. Conduit arterial wall thickening precedes left ventricular remodeling in essential hypertension and is significantly related to the degree of pressure elevation and the arterial waveform contour.
Collapse
Affiliation(s)
- F D Tice
- Department of Internal Medicine, Division of Cardiology, The Ohio State University, Columbus
| | | | | | | | | | | | | |
Collapse
|
13
|
|
14
|
Khot UN, Binkley PF, Haas GJ, Starling RC. Prospective study of the circadian pattern of blood pressure after heart transplantation. J Heart Lung Transplant 1996; 15:350-9. [PMID: 8732593] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Previous reports indicate that heart transplant recipients lack a normal nocturnal decline in blood pressure. This prospective study was designed to determine the evolution of circadian blood pressure patterns after heart transplantation. METHODS Twenty-four-hour ambulatory blood pressure and heart rate was measured in eight heart transplant recipients early (47 +/- 35 days) and late (740 +/- 10 days) after transplantation. RESULTS Early transplant recordings and the normal control group recordings showed similar daytime systolic blood pressure but had different nighttime systolic blood pressure (138 +/- 15 mm Hg versus 112 +/- 9 mm Hg, p = 0.0002). The percent nocturnal change in systolic blood pressure showed a nocturnal increase in blood pressure in the early recordings versus a decrease in the healthy subjects (+4 +/- 2.7 versus -13 +/- 5.4, p < 0.0001). The late recordings showed a significant decrease in the nighttime systolic blood pressure (138 +/- 15 mm Hg versus 119 +/- 7 mm Hg, p = 0.011). The percent nocturnal change in systolic blood pressure was also significantly different between the early and late recordings (+4 +/- 2.7 versus -9 +/- 9, p = 0.0082) indicating a return of a nocturnal decline in systolic blood pressure. Similar patterns in diastolic blood pressure were observed. No significant change in the percent nocturnal change in heart rate occurred (-10 +/- 4.1 versus -7 +/- 5.5). CONCLUSIONS Prospective follow-up of this heart transplant population showed that diurnal blood pressure variation is restored in some patients; diurnal variation is not related to corticosteroids, cyclosporine, or heart rate.
Collapse
Affiliation(s)
- U N Khot
- Department of Internal Medicine, Ohio State University College of Medicine, Columbus, USA
| | | | | | | |
Collapse
|
15
|
Panina G, Khot UN, Nunziata E, Cody RJ, Binkley PF. Role of spectral measures of heart rate variability as markers of disease progression in patients with chronic congestive heart failure not treated with angiotensin-converting enzyme inhibitors. Am Heart J 1996; 131:153-7. [PMID: 8554003 DOI: 10.1016/s0002-8703(96)90064-2] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Measures of heart rate variability in the frequency domain quantify autonomic activity. However, the relation of these measures to the severity of ventricular dysfunction in patients with congestive heart failure remains uncertain. We applied spectral analysis of heart rate variability to 24-hour Holter monitor recordings obtained from 20 patients with congestive heart failure who were not treated with angiotensin-converting enzyme inhibitors to determine whether significant changes in parameters of heart rate variability reflect the progression of symptoms in patients with ventricular failure. Both total and low-frequency heart rate spectral power were seen to decrease with worsening New Heart Associate (NYHA) functional class. A significant (p = 0.04) higher total power was noted in NYHA class II than in class III patients (3.0 x 10(-3) +/- 3.6 10(-4) and 2.5 x 10(-3) +/- 5.9 x 19(-4) [beats/min]2, respectively). Similarly, low-frequency heart rate spectral power was significantly (p = 0.008) higher in class II than in class III patients (1.7 x 10(-3) +/- 4.6 x 10(-4) and 1.1 x 10(-3) +/- 3.5 x 10(-4) [beats/min]2, respectively). Only the low-frequency component of the spectrum was directly correlated with left ventricular ejection fraction (LVEF) (r = 0.40) with a trend toward statistical significance (p = 0.07). Measures of heart rate variability and the changes in autonomic tone that they reflect may therefore serve as markers of the extent of disease progression in patients with congestive heart failure.
Collapse
Affiliation(s)
- G Panina
- Ohio State University, Columbus, USA
| | | | | | | | | |
Collapse
|
16
|
Constable PD, Muir WW, Binkley PF. Effect of hypertonic saline solution on left ventricular afterload in normovolumic dogs. Am J Vet Res 1995; 56:1513-21. [PMID: 8585666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
The effects of hypertonic saline solution (HSS) and hyperosmotic dextrose (HD; 2,400 mosm/L, 4 ml/kg of body weight) on left ventricular afterload were determined in normovolumic, chloralose-anesthetized, autonomically blocked dogs (n = 8). Solutions were infused IV over 3 minutes. Left ventricular afterload was assessed by use of a dual-tipped micromanometer catheter with an electromagnetic fluid-velocity sensor located in the ascending aorta, and the impedance spectrum was calculated after Fourier analysis of signal-averaged aortic pressure and flow signals. Hypertonic saline solution and HD decreased peripheral resistance, reflection coefficient at zero frequency, and frequency of the first zero crossing of the phase angle for 3 to 5 minutes after either fluid was administered. Characteristic impedance was not altered by HSS or HD. These impedance spectrum changes indicate transient vasodilatation and afterload reduction. We conclude that the vascular effect of an ionic hyperosmotic solution (HSS) is similar to that of a nonionic hyperosmotic solution (HD), and that HSS and HD transiently decrease afterload in normovolumic dogs. The duration of the afterload reduction after HSS administration appeared to be too short to be of great clinical benefit.
Collapse
Affiliation(s)
- P D Constable
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Ohio State University, Columbus 43210, USA
| | | | | |
Collapse
|
17
|
Binkley PF, Orsinelli DA, Nunziata E, Patterson SP, Khot UN, Puri R, Latcham AP, Pearson AC. Differing autonomic response to dobutamine in the presence and absence of ischemia: implications for the autonomic contribution to positive inotropic intervention. Am Heart J 1995; 130:1054-61. [PMID: 7484736 DOI: 10.1016/0002-8703(95)90208-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Although it is well recognized that dobutamine is a powerful positive inotropic agent mediating increased myocardial contractility through direct beta-adrenergic stimulation, the mechanism of its overall circulatory effects appears more complex than that which may be ascribed solely to this direct action on the myocardium. Previous investigations have implied that reflex alterations in autonomic balance may contribute significantly to the response to this agent, but direct evidence describing such a response has not been reported. The objective of this investigation was to assess changes in autonomic tone induced by dobutamine in the presence and absence of ischemia through the measurement of heart rate variability in patients undergoing dobutamine stress echocardiography. Of 25 consecutive patients undergoing dobutamine stress echocardiography, 16 were found to have unequivocal evidence for or against the presence of ischemia during dobutamine infusion. Heart rate data from these 16 patients were submitted for spectral analysis of heart rate variability and quantification of parasympathetically governed high-frequency heart rate variability and sympathetically influenced low-frequency heart rate variability. Of the 16 patients nine were not found to have evidence for ischemia (group 1), and seven were found to have echocardiographic findings consistent with dobutamine-induced ischemia (group 2). The two groups significantly differed (p = 0.04) in the change in parasympathetic tone associated with dobutamine with a significant (p = 0.04) increase in parasympathetic tone in group 1 and a numeric decrease in group 2. A significant (p = 0.04) decrease in sympathetic tone was noted in group 1 as reflected by low-frequency heart rate variability with a numeric increase in this measure in group 2.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- P F Binkley
- Division of Cardiology, Ohio State University Medical Center, Columbus 43210, USA
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Eaton GM, Cody RJ, Nunziata E, Binkley PF. Early left ventricular dysfunction elicits activation of sympathetic drive and attenuation of parasympathetic tone in the paced canine model of congestive heart failure. Circulation 1995; 92:555-61. [PMID: 7634470 DOI: 10.1161/01.cir.92.3.555] [Citation(s) in RCA: 47] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
BACKGROUND Although autonomic imbalance is known to be characteristics of patients with clinically overt symptomatic congestive heart failure, it is currently unknown whether this autonomic response arises early in the course of left ventricular dysfunction or is restricted to the later stages of circulatory failure. METHODS AND RESULTS This investigation utilized the technique of spectral analysis of heart rate variability in a paced canine model of congestive heart failure that permits an examination of autonomic activity at the earliest stages of ventricular dysfunction to determine whether early systolic dysfunction in congestive heart failure is characterized by autonomic imbalance, which may contribute to subsequent myocardial and vascular dysfunction. The results indicate that autonomic imbalance as reflected in an abnormal pattern of heart rate variability evolves early in the course of ventricular systolic dysfunction consisting of both a significant increase in sympathetically influenced low-frequency heart rate variability and a significant reduction of parasympathetically mediated high-frequency variability. This was quantified by a marked and significant increase in the area under the low-frequency region from 0.053 +/- 0.037 (beats per minute)2 at baseline to 0.182 +/- 0.143 (beats per minute)2 at 48 hours to 0.253 +/- 0.202 (beats per minute)2 after 7 days of pacing (ANOVA, P < .04). The area under the high-frequency region of the curve showed a decrease from a baseline value of 0.945 +/- 0.037 (beats per minute)2 to 0.811 +/- 0.152 (beats per minute)2 at 48 hours to 0.733 +/- 0.197 (beats per minute)2 after 7 days of pacing (ANOVA, P < .03). This resulted in a shift in autonomic balance away from parasympathetic tone and toward augmented sympathetic drive as reflected by the ratio of high- to low-frequency areas from a baseline value of 15.2 +/- 9.6 to 10.1 +/- 6.89 at 48 hours and 0.004 +/- 0.001 at 7 days (ANOVA, P < .01). CONCLUSIONS The results indicate that autonomic imbalance as reflected in an abnormal pattern of heart rate variability evolves early in the course of ventricular systolic dysfunction consisting of both a significant increase in sympathetically influenced low-frequency heart rate variability and a significant reduction of parasympathetically mediated high-frequency variability. The early appearance of these autonomic abnormalities suggests that autonomic imbalance plays a significant role in promoting the progression of circulatory failure.
Collapse
Affiliation(s)
- G M Eaton
- Department of Medicine, Ohio State University, Columbus 43210, USA
| | | | | | | |
Collapse
|
19
|
Cody RJ, Binkley PF, Haas GJ, Brown DM. Acute myocardial and vascular responses to specific angiotensin II antagonism in the spontaneously hypertensive rat. Am J Hypertens 1995; 8:500-8. [PMID: 7662227 DOI: 10.1016/0895-7061(95)00019-l] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
Abstract
As the AT1 receptor is the primary angiotensin II receptor in the myocardium and vasculature, we assessed the acute myocardial and vascular response to the AT1 angiotensin II antagonist losartan in the spontaneously hypertensive rat (SHR) to determine the contribution of angiotensin II in this genetic form of hypertension. In a preliminary dose response study, which evaluated losartan at 1.0, 3.0, and 10 mg/kg, 10 mg/kg uniformly lowered blood pressure. In a second group of experiments, 10 mg/kg also completely attenuated the pressor effects of angiotensin II administration. In nine adult SHR, intravenous losartan, 10 mg/kg, was given, with hemodynamics measured immediately and at steady-state intervals to delineate the hemodynamic response to angiotensin II antagonism. Losartan significantly lowered systolic, diastolic, and mean blood pressures, yet heart rate was unchanged. Cardiac function, as assessed by cardiac output and blood flow acceleration, demonstrated only transient increases which were not sustained during steady-state blood pressure reduction. Significant increases of peak blood flow and pulse pressure were sustained throughout the blood pressure response. At immediate and steady-state determinations, system vascular resistance and characteristic aortic impedance were significantly reduced with losartan (both P < .01). In addition, concomitant reduction of the wave reflectance index also occurred, achieving significance at steady state (P < .05). These changes demonstrate that the AT1 angiotensin II receptor contributes to both central and peripheral vasoconstriction in the spontaneously hypertensive rat. Absence of sustained increase of cardiac output and blood flow acceleration are consistent with inhibition of the previously reported positive inotropic effect of angiotensin II.
Collapse
Affiliation(s)
- R J Cody
- Department of Medicine, Ohio State University Medical Center, Columbus 43210, USA
| | | | | | | |
Collapse
|
20
|
Panina G, Khot UN, Nunziata E, Cody RJ, Binkley PF. Assessment of autonomic tone over a 24-hour period in patients with congestive heart failure: relation between mean heart rate and measures of heart rate variability. Am Heart J 1995; 129:748-53. [PMID: 7900627 DOI: 10.1016/0002-8703(95)90325-9] [Citation(s) in RCA: 48] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Patients with congestive heart failure (CHF) are characterized by an imbalance of the autonomic nervous system, which may contribute to the progression of circulatory failure and influence survival. However, it is still unclear whether CHF is characterized by a suppression of the diurnal variation in autonomic tone that is observed in normal subjects. To characterize the circadian variation in autonomic tone in patients with ventricular failure, ambulatory 24-hour Holter monitor recordings were obtained in 20 patients with CHF; 4-minute epochs of data from every hour of each 24-hour recording were selected. For each epoch we calculated the mean heart rate (HR) and, by applying spectral analysis of heart rate variability (HRV), we quantified the magnitude of the total (0.02 to 0.9 Hz), sympathetically governed low frequency variability (0.02 to 0.1 Hz), and parasympathetically mediated high-frequency variability (0.1 to 0.9 Hz). These areas were also expressed as a ratio to total variability and a ratio of high to low variability. A highly significant change in the mean HR over 24 hours was observed (p = 0.0001); no changes in the measures of HRV were obtained (p < 0.3). No significant correlation was found between mean HR and any frequency domain measures. We conclude that the sustained imbalance of autonomic tone over a 24-hour period, as shown by the spectral analysis of HRV, may promote the progression of circulatory failure and predispose patients with CHF to malignant ventricular arrhythmias and sudden cardiac death.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- G Panina
- Department of Medicine, Ohio State University, Columbus
| | | | | | | | | |
Collapse
|
21
|
|
22
|
Affiliation(s)
- P F Binkley
- Ohio State University Medical Center, Columbus
| | | | | | | | | |
Collapse
|
23
|
Binkley PF, Nunziata E, Cody RJ. Influence of flosequinan on autonomic tone in congestive heart failure: implications for the mechanism of the positive chronotropic effect and survival influence of long-term vasodilator administration. Am Heart J 1994; 128:1147-56. [PMID: 7985595 DOI: 10.1016/0002-8703(94)90745-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
The vasodilator flosequinan has been shown to be effective in the management of symptoms of congestive heart failure but has been found to influence survival adversely when administered in selected doses. A moderate positive chronotropic response accompanies long-term administration of this agent, which may be associated with an activation of the neurohormonal axis that itself may contribute to the reported increase in mortality. This investigation used the technique of spectral analysis of heart rate variability to examine the autonomic response to long-term flosequinan administration in 39 patients enrolled in a double-blind placebo-controlled trial of this vasodilator to determine whether autonomic mechanisms account for the observed changes in heart rate. Although heart rate significantly increased in the flosequinan-treated patients, parasympathetic tone increased and sympathetic drive decreased compared with placebo, as reflected by high- and low-frequency heart rate variabilities, respectively. It is concluded that (1) autonomic inputs to the myocardium that would be expected to produce increases in heart rate do not result from long-term flosequinan administration; (2) accordingly, a direct positive chronotropic effect must account for the heart rate changes observed with this vasodilator; and (3) the increased mortality associated with the administration of this agent in the doses examined does not appear to result from reflex changes in autonomic tone and must result from other properties of this vasodilator.
Collapse
Affiliation(s)
- P F Binkley
- Department of Medicine, Ohio State University, Columbus
| | | | | |
Collapse
|
24
|
Cacioppo JT, Berntson GG, Binkley PF, Quigley KS, Uchino BN, Fieldstone A. Autonomic cardiac control. II. Noninvasive indices and basal response as revealed by autonomic blockades. Psychophysiology 1994; 31:586-98. [PMID: 7846219 DOI: 10.1111/j.1469-8986.1994.tb02351.x] [Citation(s) in RCA: 258] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Heart period, systolic time intervals, low and high frequency heart period variability, blood pressure, and respiration were measured in female subjects under three drug conditions (saline, atropine sulfate, metoprolol) while sitting and standing on three consecutive days. Following preinfusion baseline recordings, saline, metoprolol (14 mg), or atropine sulfate (2 mg) was infused for 15 min (by using a double-blind procedure). Recordings were taken during a postinfusion baseline and in response to an orthostatic stressor (standing versus sitting postures). At the end of the metoprolol session, atropine sulfate was infused and responses were monitored during the postinfusion (i.e., double blockade) baseline and during orthostatic stressor. Analyses of the blockade data revealed that the preejection period (PEP) reflected sympathetic but not vagal influences on the heart, and high frequency (HF, 0.12-0.40 Hz) heart rate variability (respiratory sinus arrhythmia) reflected vagal but not sympathetic influences on the heart. No other measure provided a specific index of the tonic sympathetic or vagal activation of the heart. Postinfusion PEP under saline predicted individual differences in postinfusion cardiac sympathetic activation, whereas postinfusion heart period (but not HF variability) under saline predicted individual differences in postinfusion cardiac vagal activation.
Collapse
Affiliation(s)
- J T Cacioppo
- Department of Psychology, Ohio State University, Columbus 43210-1222
| | | | | | | | | | | |
Collapse
|
25
|
Berntson GG, Cacioppo JT, Binkley PF, Uchino BN, Quigley KS, Fieldstone A. Autonomic cardiac control. III. Psychological stress and cardiac response in autonomic space as revealed by pharmacological blockades. Psychophysiology 1994; 31:599-608. [PMID: 7846220 DOI: 10.1111/j.1469-8986.1994.tb02352.x] [Citation(s) in RCA: 309] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Behavioral contexts can evoke a variety of autonomic modes of response, characterized by reciprocal, coactive, or independent changes in the autonomic divisions. In the present study, we investigated the reactive autonomic control of the heart in response to psychological stressors, using quantitative methods for analyzing single and double autonomic blockades, and through the use of noninvasive indices based on heart period variability and systolic time intervals. Analysis of the effects of pharmacological blockades revealed an overall pattern of increased sympathetic and decreased parasympathetic control of the heart during speech stress, mental arithmetic, and a reaction-time task. Unlike the classical reciprocal sympathetic-parasympathetic response to orthostatic challenge, however, the responses of the autonomic branches to stress were uncorrelated. This reflected notable individual differences in the mode of autonomic response to stress, which had considerable stability across stress tasks. The putative noninvasive indices of sympathetic (preejection period) and parasympathetic (respiratory sinus arrhythmia) control changed in accord with the results of pharmacological blockades. Together, these results emphasize the substantial individual differences in the mode of autonomic response to stress, the advantages of a quantitative approach to analyzing blockade data, and the importance of validity estimates of blockade data.
Collapse
Affiliation(s)
- G G Berntson
- Department of Psychology, Ohio State University, Columbus 43210-1222
| | | | | | | | | | | |
Collapse
|
26
|
Khot UN, Binkley PF, Haas GJ, Starling RC. Restoration of diurnal blood pressure variability after cardiac transplantation. Transplant Proc 1994; 26:2736-7. [PMID: 7940858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- U N Khot
- Department of Internal Medicine, Ohio State University College of Medicine, Columbus
| | | | | | | |
Collapse
|
27
|
Abstract
The inotropic effects of hypertonic saline (HS) and hyperosmotic dextrose (HD; 2,400 mosmol/l, 4 ml/kg) were determined in normovolumic, chloralose-anesthetized, intact (n = 14) and autonomically blocked (n = 8) dogs. Solutions were infused intravenously over 3 min. HS and HD rapidly increased preload in both intact and autonomically blocked dogs, as assessed by significant (P < 0.05) increases in plasma volume, end-diastolic volume, and end-diastolic pressure. In intact dogs, HS produced a nonsignificant decrease in end-systolic elastance (Ees) and a nonsignificant increase in the maximal rate of change of left ventricular pressure (dP/dtmax) and cardiac output, whereas HD produced a significant increase in Ees, dP/dtmax, and cardiac output. In autonomically blocked dogs, HS significantly decreased Ees and significantly increased dP/dtmax but did not alter cardiac output, whereas HD significantly increased Ees, dP/dtmax, and cardiac output. We conclude that in normovolumic animals, HS is a negative inotropic agent, HD is a positive inotropic agent, and the in vivo effect of an ionic hyperosmotic agent (HS) differs from that of a nonionic hyperosmotic agent (HD).
Collapse
Affiliation(s)
- P D Constable
- College of Veterinary Medicine, Ohio State University, Columbus 43210
| | | | | |
Collapse
|
28
|
Pearson AC, Guo R, Orsinelli DA, Binkley PF, Pasierski TJ. Transesophageal echocardiographic assessment of the effects of age, gender, and hypertension on thoracic aortic wall size, thickness, and stiffness. Am Heart J 1994; 128:344-51. [PMID: 8037102 DOI: 10.1016/0002-8703(94)90488-x] [Citation(s) in RCA: 79] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Aging is associated with progressive arterial stiffening and widening of the pulse pressure, resulting in a high prevalence of systolic hypertension. The contribution of increased aortic thickness to this process and to essential hypertension has been poorly characterized. With transesophageal echocardiography, aortic thickness and diameter can be measured. Thus, the influence of aging, gender, and hypertension on the geometry and stiffness of the descending thoracic aorta in humans can be determined in vivo. In 83 patients undergoing transesophageal echocardiography for clinical indications, recordings of the descending thoracic aorta were made. There were 53 normotensive subjects (33 men and 20 women, mean age 46 years, range 14 to 79 years) and 25 hypertensive subjects (8 men and 17 women, mean age 67 years, range 50 to 80 years). Measurements of diastolic and systolic aortic thickness and aortic diameter were made, and three measures of the elastic properties of the aorta were calculated: (1) Peterson's elastic modulus, (2) Young's modulus, and (3) the stiffness index (beta). Aortic thickness averaged 1.1 +/- 0.1 mm in both normotensive men and women. Normotensive women had a significantly greater thickness/diameter ratio than men (0.06 +/- 0.01 vs 0.05 +/- 0.01, p < 0.01), but there were no differences in stiffness between men and women. Age was highly positively correlated with thickness (r = 0.74, p < 0.001), diameter (r = 0.67, p < 0.001), beta (r = 0.79, p < 0.001), Peterson's modulus (r = 0.78, p < 0.001), and Young's modulus (r = 0.81, p < 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- A C Pearson
- Division of Cardiology, Ohio State University, Columbus 43210-1228
| | | | | | | | | |
Collapse
|
29
|
Eaton GM, Cody RJ, Binkley PF. Increased aortic impedance precedes peripheral vasoconstriction at the early stage of ventricular failure in the paced canine model. Circulation 1993; 88:2714-21. [PMID: 8252683 DOI: 10.1161/01.cir.88.6.2714] [Citation(s) in RCA: 24] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
BACKGROUND Aortic input impedance is altered in patients with congestive heart failure. However, little is known about whether this vascular response is an early change or a late manifestation of left ventricular dysfunction. METHODS AND RESULTS This investigation used a paced canine model of congestive heart failure to demonstrate that abnormal aortic input impedance does evolve in the setting of ventricular systolic dysfunction and to prospectively define the time course of change in aortic input impedance and conduit vessel compliance. Studies were performed in closed-chest conditioned beagles aged 1 to 2 years that underwent hemodynamic evaluation at baseline and after induction of left ventricular dysfunction by rapid ventricular pacing. Within 48 hours of the onset of rapid ventricular pacing, we observed mild left ventricular systolic dysfunction with an echocardiographically derived left ventricular ejection fraction of 37% (p < .001 compared with baseline) measured during interruption of rapid ventricular pacing. Concomitant with this reduction in left ventricular systolic function, the aortic input impedance spectrum was shifted above baseline in all dogs studied. Characteristic impedance of the aorta significantly increased from 121 +/- 65 dynes.s/cm5 to 186 +/- 114 dynes.s/cm5 (P < .02), and a significant increase in the first modulus of impedance from 137 +/- 43 dynes.s/cm5 to 228 +/- 139 dynes.s/cm5 was observed (P < .05). Although characteristic aortic impedance increased by 50%, there was at this point no change in peripheral vascular resistance. Therefore, these abnormalities in aortic input impedance are representative of an early vascular change that evolves in response to ventricular systolic dysfunction. CONCLUSIONS Considering the early appearance of these findings, the resultant impaired power transfer and reduced conduit vessel compliance likely contribute to the progression of abnormal myocardial energetics and systolic dysfunction characteristic of ventricular failure.
Collapse
Affiliation(s)
- G M Eaton
- Ohio State University, Department of Medicine, Columbus 43210
| | | | | |
Collapse
|
30
|
Murray KD, Binkley PF, Dumond DA, Watson KM, Howanitz EP, Ross P, Myerowitz PD. The significance and prevention of air emboli with the total artificial heart. Artif Organs 1993; 17:734-40. [PMID: 8215956 DOI: 10.1111/j.1525-1594.1993.tb00623.x] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Embolism remains a significant complication of the total artificial heart (TAH). The ineffectual deairing of the TAH can allow embolization of the retained air. The standard needle aspiration of TAH air (Group A) was compared with a new protocol (Group B) that included standard needle TAH aspiration plus simultaneous pumping of the TAH against an occluded ascending aorta and main pulmonary artery with vacuum applied to a needle in the proximal aorta and pulmonary artery. There were 4 calves in each group. There was no premortem evidence of systemic or pulmonary emboli. Both groups of animals were electively terminated less than 2 weeks postoperatively Postoperative mean aortic and pulmonary artery pressures were recorded for each animal. Animals in Group B had a significant decline in pulmonary artery pressures (43 +/- 12 vs. 33 +/- 8 mm Hg) 1 h after TAH implantation when compared with Group A. All other aortic and pulmonary artery pressure differences between Groups A and B were not statistically significant within 24 h of the operation. Group A animals had a 75% incidence, and Group B animals had 100% incidence of TAH thrombus. This very small thrombus was found exclusively at the inflow valve-TAH housing interface. Evaluation of the kidneys postmortem was used to identify embolic injury. All animals in Group A had evidence of acute, hemorrhagic injury, but none of the Group B animals had similar injury. Half of the animals in each group had small, fibrotic chronic renal cortical injury, which did not develop during TAH implantation.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- K D Murray
- Ohio State University Hospitals, Division of Thoracic and Cardiovascular Surgery, Columbus 43210
| | | | | | | | | | | | | |
Collapse
|
31
|
Abstract
The aim of this study was to verify the hypothesis that pulmonary artery (PA) distensibility may modify the pattern of right ventricular ejection. Pulmonary artery distensibility was evaluated with M-mode measurements of right pulmonary artery diameter from suprasternal notch simultaneous with pulmonary pressure measurements. Pulmonary artery pressure was measured in 19 subjects, 29 to 75 years old (mean age, 49 years). Pulmonary artery systolic pressure was 22 to 108 mm Hg (mean, 52 mm Hg). Pulmonary artery pressure strain modulus (Ep) was calculated as follows: PADD x (PASP-PADP)/PADD-PADS (PADS-PA diameter in systole, PADD-PA diameter in diastole, PASP-PA systolic pressure, PADP-PA diastolic pressure) was 6 +/- 8 10(5) dynes/cm2. Right ventricular outflow tract velocity was recorded with pulsed Doppler echocardiography and acceleration times (AT) and ejection times (ET) were measured. Log Ep was correlated with pulmonary artery systolic and mean pressure (r = 0.90 and r = 0.87, p < 0.0001) but not with age (r = 0.30, p = NS). Acceleration time and AT/ET ratio were correlated with log Ep (r = 0.73 and r = 0.76, p < 0.001) and with pulmonary artery mean pressure (r = 0.91 and r = 0.89, p < 0.0001). When pulmonary artery pressure was included in multiple analyses, the relationships between Doppler indices and elastic modulus did not prove to be significant. These findings emphasize the independence of Doppler right ventricular outflow tract velocity indexes used for noninvasive evaluation of pulmonary hypertension from pulmonary artery distensibility in a clinical setting.
Collapse
Affiliation(s)
- T J Pasierski
- Department of Internal Medicine, Ohio State University, Columbus
| | | | | | | |
Collapse
|
32
|
Binkley PF, Haas GJ, Starling RC, Nunziata E, Hatton PA, Leier CV, Cody RJ. Sustained augmentation of parasympathetic tone with angiotensin-converting enzyme inhibition in patients with congestive heart failure. J Am Coll Cardiol 1993; 21:655-61. [PMID: 8436747 DOI: 10.1016/0735-1097(93)90098-l] [Citation(s) in RCA: 163] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
OBJECTIVES The objective of this investigation was to evaluate the changes in parasympathetic tone associated with long-term angiotensin-converting enzyme inhibitor therapy in patients with congestive heart failure. BACKGROUND Angiotensin-converting enzyme inhibitors provide hemodynamic and symptomatic benefit and are associated with improved survival in patients with congestive heart failure. Angiotensin II, whose production is ultimately inhibited by these agents, exerts significant regulatory influence on a variety of target organs including the central and peripheral nervous systems. Accordingly, it would be anticipated that angiotensin-converting enzyme inhibitors would significantly alter the autonomic imbalance characteristic of patients with congestive heart failure and that this influence over neural mechanisms of cardiovascular control may significantly contribute to the hemodynamic benefit and improved survival associated with angiotensin-converting enzyme inhibitor therapy. METHODS In the current investigation, changes in autonomic tone associated with long-term administration of an angiotensin-converting enzyme inhibitor were measured using spectral analysis of heart rate variability in 13 patients with congestive heart failure who were enrolled in a double-blind randomized placebo-controlled trial of the angiotensin-converting enzyme inhibitor zofenopril. Both placebo and treatment groups were balanced at baseline study in terms of functional class, ventricular performance and autonomic tone. RESULTS After 12 weeks of therapy with placebo, there was no change in total heart rate variability, parasympathetically governed high frequency heart rate variability or sympathetically influenced low frequency heart rate variability. In contrast, therapy with zofenopril was associated with a 50% increase in total heart rate variability (p = 0.09) and a significant (p = 0.03) twofold increase in high frequency heart rate variability, indicating a significant augmentation of parasympathetic tone. CONCLUSIONS These results demonstrate that long-term treatment of patients having congestive heart failure with an angiotensin-converting enzyme inhibitor is associated with a restoration of autonomic balance, which derives in part from a sustained augmentation of parasympathetic tone. Such augmentation of vagal tone is known to be protective against malignant ventricular arrhythmias in patients with ischemic heart disease and therefore may have similar benefit in the setting of ventricular failure, thus contributing to the improved survival associated with angiotensin-converting enzyme inhibitor therapy in patients with congestive heart failure.
Collapse
Affiliation(s)
- P F Binkley
- Department of Medicine, Ohio State University Hospital, Columbus 43210
| | | | | | | | | | | | | |
Collapse
|
33
|
Abstract
After cardiac transplantation, cyclosporine-treated patients exhibit a high incidence of systemic hypertension, the mechanism of which is not known. Endothelin, a potent vasoconstrictor peptide of endothelial origin, may be activated by cyclosporine-induced endothelial injury and therefore may mediate post-transplant hypertension. In the present study, we tested whether immunoreactive endothelin-1 could be detected by radioimmunoassay in the plasma of cardiac transplant recipients and if levels correlated with hemodynamic characteristics, cyclosporine level, or renal function as assessed by serum creatinine. Plasma endothelin was measured in 22 stable cyclosporine-treated patients 9 days to 3 years after successful orthotopic cardiac transplantation before routine hemodynamic assessment and surveillance endomyocardial biopsy. Fifteen patients were receiving chronic therapy for hypertension. Plasma endothelin-1 was 5.2 +/- 1.8 pg/ml (range 3.1 to 10.5), which was increased compared with that in 12 normal subjects (1.9 +/- 0.3 pg/ml; range 1.4 to 2.4); the difference was statistically significant (p < 0.0001). Repeated sampling in 8 patients at weekly intervals identified a persistent increase in endothelin with only modest variability. Endothelin-1 did not correlate with any hemodynamic variable, serum creatinine or cyclosporine level. Thus, endothelin-1 is increased after successful orthotopic cardiac transplantation. In the absence of discrete correlations with hemodynamic variables, serum creatinine or cyclosporine levels, both the characteristics and mechanisms for increased endothelin in recipients of cardiac transplants require further evaluation.
Collapse
Affiliation(s)
- G J Haas
- Division of Cardiology, Ohio State University Hospitals, Columbus 43210
| | | | | | | | | | | |
Collapse
|
34
|
Starling RC, Binkley PF, Haas GJ, Hatton PS, Wooding-Scott M. Thermodilution measures of right ventricular ejection fraction and volumes in heart transplant recipients: a comparison with radionuclide angiography. J Heart Lung Transplant 1992; 11:1140-6. [PMID: 1333800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
A reliable, convenient measure of right ventricular ejection fraction may be a useful adjunct to evaluate cardiac allograft rejection. The purpose of this investigation was to compare two measures of right ventricular ejection fraction: (1) radionuclide angiography with the first-pass technique and (2) thermodilution with a balloon flotation catheter. The study was performed in 26 heart transplant recipients; hemodynamics, thermodilution cardiac output, and right ventricular ejection fraction were measured. First pass radionuclide angiography was performed either simultaneously (n = 11) or within 4 hours (n = 15) of the thermodilution study. Mean thermodilution right ventricular ejection fraction was 39% +/- 8%, and radionuclide angiography ejection fraction was 47% +/- 9%, which represents a highly significant difference (p < 0.001) in techniques. Linear regression showed no correlation between the two techniques (r = 0.3; p = NS). No differences in results were observed in those studied simultaneously versus less than 4 hours. We conclude that the thermodilution technique underestimates right ventricular ejection fraction in heart transplant recipients and that its usefulness as a tool to screen for systolic dysfunction related to rejection is limited.
Collapse
Affiliation(s)
- R C Starling
- Department of Internal Medicine, Ohio State University, Columbus 43210
| | | | | | | | | |
Collapse
|
35
|
Murray KD, Binkley PF, Watson KM, Howanitz EP, Ross P, Myerowitz PD. Remnant atrial function in human and animal recipients of a total artificial heart. J Heart Lung Transplant 1992; 11:1066-72. [PMID: 1457429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022] Open
Abstract
The native atria remains intact after total artificial heart (TAH) implantation. The electrical activity of the recipient's atria can be recorded from wires placed during TAH implantation. Regulating TAH heart rate by coupling it with native atrial activity has the potential for a more physiologically responsive TAH. The reactivity of the atrial impulse rate is a critical component of this link, but little is known about atrial responsiveness after TAH placement. Two human and three animal TAH recipients had recordable atrial electrical activity. Human atrial impulse rate after TAH was relatively constant at rest but unresponsive to physiologic stimuli. Analysis of human atrial contraction provided no discernable effect on ventricular filling. Animal atrial impulse rate at rest was more rapid than calves without a TAH. The bovine TAH recipients had an atrial impulse rate that responded to catecholamine stimulation and blockade. Isoproterenol caused a significant rise in atrial impulse rate (152 +/- 16 impulses per minute to 216 +/- 24 impulses per minute; p < 0.05) and propranolol caused a decrease in atrial impulse rate (142 +/- 20 impulses per minute to 122 +/- 19 impulses per minute; p > 0.05). Despite beta blockade, the atrial impulse rate remained abnormally elevated secondary to unknown factors. Animal atrial contraction did appear to intermittently augment TAH ventricular filling. These data indicate that the atria remains electrically intact after TAH implantation. The human atrial impulse rate was unresponsive to physiologic stimuli although the animal atrial impulse rate was affected by exogenous catecholamine administration, but the rate remained abnormally rapid.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- K D Murray
- Ohio State University Hospitals, Division of Thoracic and Cardiovascular Surgery, Columbus 43210
| | | | | | | | | | | |
Collapse
|
36
|
Tice FD, Jungbluth GL, Binkley PF, MacKichan JJ, Mohrland JS, Wolf DL, Leier CV, Bindley PF. Clinical pharmacology of nicorandil in patients with congestive heart failure. Clin Pharmacol Ther 1992; 52:496-503. [PMID: 1424424 DOI: 10.1038/clpt.1992.177] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Nicorandil is a nicotinamide derivative with a potential role in human therapeutics because of its potent vasodilating properties. The pharmacokinetics of oral nicorandil administration and the relationships between plasma nicorandil concentration and hemodynamic responses were examined in 25 patients with moderate to severe congestive heart failure. The dose range from 10 to 60 mg was studied. Elimination half-life for this dose range was substantially longer than that previously reported in normal volunteers. Total area under the curve increased in a curvilinear fashion with progressive dose increments, indicating a disproportionate increase in systemically available drug at higher doses. Hemodynamic responses generally correlated well with plasma nicorandil concentration, with rapid loss of cardiovascular activity corresponding to the efficient clearance of nicorandil.
Collapse
Affiliation(s)
- F D Tice
- Division of Cardiology, Ohio State University College of Medicine, Columbus 43210
| | | | | | | | | | | | | | | |
Collapse
|
37
|
Abstract
Distensibility of the descending aorta was evaluated during routine transesophageal echocardiography (TEE) in 50 subjects (16 to 80 years, average age 53). M-mode measurements of aortic systolic (SD) and diastolic diameter (DD) were taken distal to the left subclavian artery. Simultaneously, cuff brachial artery systolic (SBP) and diastolic (DBP) pressures were measured. Aortic pressure strain modulus (Ep), calculated as brachial artery pulse pressure/aortic strain, averaged 1.19 +/- 0.95 10(6) dynes/cm2. Elasticity index beta, defined as 1n (SBP/DBP)/aortic strain, averaged 3.77 +/- 2.12. Both Ep and beta were correlated with age (r = 0.65, p less than 0.001; and r = 0.70, p less than 0.0001). In 20 subjects aortic pulse wave velocity was assessed at the same time using simultaneous high fidelity recordings of carotid and femoral artery pressure waveforms. Aortic pulse wave velocity averaged 818 +/- 231 cm/sec and was correlated with Ep (r = 0.60, p less than 0.01) and with age (r = 0.55, p less than 0.05). Intraobserver and interobserver variability for aortic diameter measurement ranged from 0.2 to 0.5 mm.
Collapse
Affiliation(s)
- T J Pasierski
- Ohio State University, Department of Internal Medicine, Columbus
| | | | | |
Collapse
|
38
|
Cody RJ, Haas GJ, Binkley PF, Capers Q, Kelley R. Plasma endothelin correlates with the extent of pulmonary hypertension in patients with chronic congestive heart failure. Circulation 1992; 85:504-9. [PMID: 1735147 DOI: 10.1161/01.cir.85.2.504] [Citation(s) in RCA: 461] [Impact Index Per Article: 14.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
BACKGROUND Endothelin is a family of potent vasoconstrictor peptides of vascular endothelial origin. Although it has been proposed that the vasoconstrictor effects of endothelin are produced at the local vascular level, increased plasma concentration of endothelin has been identified in cardiovascular disorders. METHODS AND RESULTS We tested whether immunoreactive endothelin-1 could be detected by radioimmunoassay in plasma of congestive heart failure patients and whether levels correlated with hemodynamic characteristics. Twenty congestive heart failure patients (New York Heart Association class II-IV) were sampled in the morning after an overnight fast, before medication. Cardiac index was decreased to 2.14 +/- 0.45 l/m/m2, and pulmonary wedge pressure was increased to 22 +/- 7 mm Hg. The ranges of pulmonary pressures were: systolic, 22-100 mm Hg, mean, 13-61 mm Hg, and diastolic, 8-42 mm Hg. The endothelin-1 level was 9.07 +/- 4.13 pg/ml (range, 4-19 pg/ml), which was increased compared with 12 normals (3.7 +/- 0.6 pg/ml; range, 2.8-4.7 pg/ml); the difference was statistically significant (p less than 0.0001). Endothelin-1 significantly correlated with pulmonary pressures (systolic, r = 0.78; mean, r = 0.80; diastolic, r = 0.77; all p less than 0.003) and pulmonary vascular resistance (r = 0.65, p less than 0.01). Endothelin-1 strongly correlated with the resistance ratio (pulmonary vascular resistance/systemic vascular resistance) (r = 0.88, p less than 0.0001). Stepwise multiple regression analysis confirmed the significance of these observations. CONCLUSIONS Elevated immunoreactive endothelin-1 specifically correlated with the extent of pulmonary hypertension in congestive heart failure patients. Whether endothelin-1 is a regional mediator of pulmonary hypertension or a marker for its occurrence requires additional evaluation.
Collapse
Affiliation(s)
- R J Cody
- Department of Medicine, Ohio State University Hospitals, College of Medicine, Columbus, Ohio 43210
| | | | | | | | | |
Collapse
|
39
|
Affiliation(s)
- P F Binkley
- Division of Cardiology, Ohio State University Hospital, Columbus 43210
| | | | | | | |
Collapse
|
40
|
Binkley PF, Murray KD, Watson KM, Myerowitz PD, Leier CV. Dobutamine increases cardiac output of the total artificial heart. Implications for vascular contribution of inotropic agents to augmented ventricular function. Circulation 1991; 84:1210-5. [PMID: 1884450 DOI: 10.1161/01.cir.84.3.1210] [Citation(s) in RCA: 28] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
BACKGROUND The synthetic catecholamine dobutamine increases stroke volume in normal subjects and in patients with congestive heart failure. In addition to its direct influence on myocardial contractility, dobutamine may significantly modulate vascular tone because of its alpha- and beta-adrenergic agonist activity. METHODS AND RESULTS To test the hypothesis that such vasoactive properties significantly contribute to the improved ventricular performance noted with this agent, hemodynamic parameters were measured during stepped ascension infusion of dobutamine in a model that is insensitive to positive inotropic stimulation. Administration of dobutamine in nine calves that underwent replacement of the native right and left ventricles with pneumatically driven total artificial hearts resulted in a significant (p = 0.0001) increase in cardiac output from 7.0 +/- 1.8 to 8.2 +/- 1.8 l/min and a significant (p = 0.0001) decrease in total peripheral vascular resistance from 1,224 +/- 559 to 745 +/- 317 dyne.sec/cm5. A less marked influence was noted on the pulmonary vasculature, with pulmonary vascular resistance exhibiting a significant (p less than 0.05) decrease from its baseline value only at the peak infusion. Consistent with an increase in venous return, both left and right atrial pressures increased significantly (p less than 0.005) with dobutamine administration. CONCLUSIONS These data demonstrate that the vasoactive properties of dobutamine significantly contribute to improved ventricular performance independent of direct myocardial stimulation. This effect appears to result in part from a direct modulation of myocardial stimulation. This effect appears to result in part from a direct modulation of arterial and venous tones rather than from a reflex response to primary changes in contractility.
Collapse
Affiliation(s)
- P F Binkley
- Division of Cardiology, Ohio State University Hospital, Columbus 43210
| | | | | | | | | |
Collapse
|
41
|
Binkley PF, Nunziata E, Haas GJ, Nelson SD, Cody RJ. Parasympathetic withdrawal is an integral component of autonomic imbalance in congestive heart failure: demonstration in human subjects and verification in a paced canine model of ventricular failure. J Am Coll Cardiol 1991; 18:464-72. [PMID: 1856414 DOI: 10.1016/0735-1097(91)90602-6] [Citation(s) in RCA: 280] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Although enhanced sympathetic tone is a well recognized component of the autonomic profile characteristic of congestive heart failure, the contribution of parasympathetic withdrawal to this autonomic imbalance is less well described. The technique of spectral analysis of heart rate variability provides a dynamic map of sympathetic and parasympathetic tone and was thus used to define the nature of sympathetic-parasympathetic interactions in humans with idiopathic dilated cardiomyopathy and in a paced canine model of congestive heart failure. Humans with cardiomyopathy were found to have an augmentation of the sympathetically mediated low frequency area of the power density spectrum. Parasympathetic withdrawal was demonstrated by significant reductions in the parasympathetically mediated high frequency area (p less than 0.05) and the ratio of high to low frequency areas (p less than 0.01). Administration of atropine to normal subjects resulted in a significant reduction in the high frequency area (p less than 0.05) and the high/low frequency area ratio, both of which decreased within the range noted in patients with congestive heart failure. Administration of isoproterenol in normal subjects led to an augmentation of the low frequency area but to only a small decrease in the high/low frequency area ratio. Induction of congestive heart failure in a paced canine model resulted in alterations in the autonomic profile that resembled those seen in humans with ventricular failure. The prominent high frequency region of the spectrum at baseline, indicating a predominance of parasympathetic tone, was absent after the evolution of congestive heart failure, and there was a marked augmentation of the low frequency region of the spectrum.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- P F Binkley
- Department of Medicine, Ohio State University, Columbus 43210
| | | | | | | | | |
Collapse
|
42
|
Starling RC, Hammer DF, Binkley PF, Galbraith TA, Howanitz EP, Murray KD, Watson KM, Myerowitz PD. Adenine nucleotide content in cold preserved human donor hearts and subsequent cardiac performance after orthotopic heart transplantation. J Heart Lung Transplant 1991; 10:508-16; discussion 517. [PMID: 1911793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
Abstract
Myocardial high-energy phosphate content has been used as a parameter to evaluate the adequacy of donor organ preservation. The purpose of this study was to assess current techniques of preservation by measuring high-energy phosphates in cold preserved (4 degrees C) human donor hearts. Endomyocardial biopsy samples of the donor heart right ventricular septum (n = 24) were compared with samples from patients with normal cardiac function evaluated before chemotherapy (n = 12). Left ventricular and right ventricular ejection fractions were measured by means of radionuclide angiography early (24 to 72 hours) and late (mean 42 days) postoperatively. Mean total cold ischemic time was 146 +/- 54 minutes (range, 89 to 340 minutes). ATP nmol/mg noncollagenous protein in donor hearts was 38.2 +/- 10.7 and 31.9 +/- 13.6 (p = NS) in normal hearts. Early postoperative left ventricular and right ventricular ejection fraction was 55% +/- 14% and 40% +/- 9%, respectively. Late postoperative left ventricular and right ventricular ejection fraction was 64% +/- 14% and 50% +/- 10%, respectively; both represent significant increases in right and left ventricular ejection fraction (p less than 0.05). No correlation was found between ischemic time and donor ATP, ischemic time and ejection fraction, or ejection fraction and ATP. Three patients with normal donor heart ATP content had severe, but reversible, early graft dysfunction. In summary, currently used human donor heart preservation techniques are associated with normal values of high-energy phosphates and usually excellent early and late postoperative graft function.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- R C Starling
- Department of Internal Medicine, Ohio State University College of Medicine, Columbus
| | | | | | | | | | | | | | | |
Collapse
|
43
|
Abstract
The catecholamines remain a major therapeutic group in intensive cardiac care; this group of compounds evokes a positive inotropic response and vascular effects ranging from vasoconstriction to little net effect to vasodilatation. Hemodynamics and clinical guidelines now allow a proper selection of the optimal catecholamine. Additional mechanisms of action and a better understanding of the clinical application of this important drug group are continuing to unfold.
Collapse
Affiliation(s)
- C V Leier
- Division of Cardiology, Ohio State University College of Medicine, Columbus 43210
| | | |
Collapse
|
44
|
Murray KD, Kalanges LK, Weiland JE, Binkley PF, Howanitz EP, Galbraith TA, Myerowitz PD. Platypnea-orthodeoxia: an unusual indication for surgical closure of a patent foramen ovale. J Card Surg 1991; 6:62-7. [PMID: 1799735 DOI: 10.1111/j.1540-8191.1991.tb00565.x] [Citation(s) in RCA: 29] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Platypnea-orthodeoxia is an infrequently reported clinical form of position dependent dyspnea and oxygen desaturation. There are several diverse etiologies for this syndrome. This case report of a patient with platypnea-orthodeoxia is the first known presentation of a case secondary to a patent foramen ovale and idiopathic hemidiaphragm paralysis. A major problem with this disease is the clinical recognition of its existence. Full recovery is possible with proper assessment of clinical signs and symptoms, appropriate noninvasive diagnostic tests, and corrective surgery in selective cases.
Collapse
Affiliation(s)
- K D Murray
- Division of Thoracic and Cardiovascular Surgery, Ohio State University Hospitals and Clinics, Columbus
| | | | | | | | | | | | | |
Collapse
|
45
|
Abstract
To ascertain the clinical relevance of terminal electrocardiographic (ECG) QRS prolongation in the setting of inferior myocardial infarction, 32 patients were studied by radionuclide ventriculography to evaluate regional left ventricular contractility. Of the 32 patients, 16 had evidence of terminal QRS prolongation and notching associated with inferior myocardial infarction, and 16 had isolated ECG evidence of inferior myocardial infarction without terminal QRS prolongation. The regional ejection fraction in the posterolateral and inferoapical regions of patients with terminal conduction delay was lower than those without this conduction delay. This group also demonstrated a lower global ejection fraction than those patients with ECG evidence of inferior myocardial infarction without terminal QRS changes. Terminal QRS abnormalities are important qualitative predictors of left ventricular dysfunction in the setting of inferior myocardial infarction.
Collapse
Affiliation(s)
- D G Babbitt
- Department of Medicine, Ohio State University, Columbus
| | | | | |
Collapse
|
46
|
Krukemyer JJ, Boudoulas H, Binkley PF, Lima JJ. Comparison of hypersensitivity to adrenergic stimulation after abrupt withdrawal of propranolol and nadolol: influence of half-life differences. Am Heart J 1990; 120:572-9. [PMID: 2389694 DOI: 10.1016/0002-8703(90)90013-n] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
To test whether a beta-blocker's pharmacokinetics has an effect on the development of the beta-blocker withdrawal syndrome, we compared response to exercise and isoproterenol after abrupt withdrawal of two beta-blockers, one with a short half-life (propranolol) and one with a long half-life (nadolol). Eight normal males participated in the randomized cross-over trial. They took propranolol, 40 mg every 6 hours for 6 days, and nadolol, 80 mg daily for 7 days. Exercise- and isoproterenol-induced changes in heart rate and pulse pressure were significantly less than control values during treatment with both drugs (p less than 0.05). Significant hypersensitivity of heart rate response was seen on days 2, 3, and 7 after propranolol withdrawal (p less than 0.05) and on day 6 after nadolol withdrawal (p less than 0.005). Hypersensitive responses to isoproterenol were seen after propranolol withdrawal; no evidence of hypersensitivity to isoproterenol was seen after nadolol withdrawal. The area under the heart rate response, time curve after nadolol withdrawal was significantly less than that after propranolol withdrawal (20.3 beats/min.day vs 44.9 beats/min.day, respectively, (p less than 0.05). There was a significant inverse correlation between the degree of hypersensitivity and nadolol pharmacokinetic half-life (r = -0.80, p less than 0.02). We conclude that abrupt withdrawal of a beta-blocker with a long half-life may protect against the development of the beta-blocker withdrawal syndrome.
Collapse
Affiliation(s)
- J J Krukemyer
- University of Tennessee, Department of Clinical Pharmacy, College of Pharmacy, Memphis 38163
| | | | | | | |
Collapse
|
47
|
Abstract
The pharmacokinetics of nadolol have been previously reported to be linear between single and steady-state dosing. Data from a study in our laboratory suggested greater than expected beta-blockade with nadolol at steady state. Because the early potency studies were single-dose studies, we hypothesized there was a nonlinearity in nadolol pharmacokinetics which produced higher than expected plasma concentrations at steady state. Six normal volunteers from the previous study (steady state) volunteered to participate in the single-dose study. Plasma concentrations were determined for 24 hr following a single dose of nadolol, 80 mg. A simple, inexpensive, and accurate method for determination of nadolol in plasma or serum by HPLC with fluorometric detection is described. The AUC0-tau at steady state was greater than the AUC0-infinity following a single dose in five of the six subjects. The mean ratio of AUCss/AUCsd was 2.54. This value would be unity in the presence of linear pharmacokinetics. We conclude that the principle of superposition is not applicable for nadolol.
Collapse
Affiliation(s)
- J J Krukemyer
- Department of Clinical Pharmacy, College of Pharmacy, University of Tennessee, Memphis
| | | | | | | |
Collapse
|
48
|
Leier CV, Binkley PF, Cody RJ. Alpha-adrenergic component of the sympathetic nervous system in congestive heart failure. Circulation 1990; 82:I68-76. [PMID: 2164897] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
The alpha-adrenergic component of the sympathetic nervous system plays a major role in the pathophysiology, clinical manifestations, and natural history of human congestive heart failure. While the augmentation of alpha-adrenergic tone (through the neuronal release of norepinephrine) is a valuable mechanism to maintain adequate systemic blood pressure and perfusion of vital organs in states of circulatory collapse, stimulation of alpha-adrenergic receptors produces detrimental hemodynamic effects in congestive heart failure. These undesirable effects result from alpha-mediated vasoconstriction and consist of excessive elevation of right and left ventricular filling pressures and pulmonary and systemic vascular resistances. The enhancement of alpha-adrenergic tone preferentially reduces blood flow to the hepatosplanchnic circulation. Many of the hemodynamic responses that are seen after activation of the renin-angiotensin system are related to the ability of angiotensin II to amplify the actions of the alpha-adrenergic system. Stimulation of myocardial alpha-adrenergic receptors in most species elicits a modest positive inotropic effect, but the presence and importance of this property in the human heart remains controversial. Chronic stimulation of myocardial alpha-adrenergic receptors may result in the hypertrophy of cardiomyocytes and may also contribute to the development of catecholamine-induced cardiomyopathy. Acute blockade of the heightened alpha-adrenergic tone in congestive heart failure (e.g., with first doses of prazosin) results in favorable hemodynamic effects, but repeated dosing leads to pharmacological tolerance. Consequently, the long-term administration of alpha-adrenergic blocking agents in human heart failure has not been accompanied by an improvement in clinical status, exercise capacity, or survival.(ABSTRACT TRUNCATED AT 250 WORDS)
Collapse
Affiliation(s)
- C V Leier
- Division of Cardiology, Ohio State University Medical Center, Columbus 43210
| | | | | |
Collapse
|
49
|
Abstract
Twenty-five patients with congestive heart failure (CHF) underwent a double-blind randomized study of the acute hemodynamic effects of orally administered nicorandil, a newly developed vasodilator drug. A dose range of 10 to 60 mg was studied. Nicorandil, at a dose of 60 mg, caused statistically significant decreases in systemic systolic and diastolic blood pressure, right atrial pressure, pulmonary capillary wedge pressure, systemic and pulmonary vascular resistance and systolic and diastolic pulmonary arterial pressure. A brief increase in cardiac index attributable to an increase in stroke volume without a change in heart rate was also observed. A dose of 40 mg produced similar results in cardiac index and systemic and pulmonary vascular resistance, but changes in other hemodynamic parameters were much smaller in magnitude and usually not of statistical significance. No significant hemodynamic response was seen to doses of 10 and 20 mg of nicorandil. Duration of action was short with nearly all hemodynamic parameters returning close to baseline within 3 hours. This rapid decrease in activity occurred in concert with a rapid plasma clearance of nicorandil as determined by serial measurements of plasma drug concentration. This study suggests that first-dose orally administered nicorandil elicits favorable, but brief, hemodynamic effects in CHF at doses greater than or equal to 40 mg.
Collapse
Affiliation(s)
- F D Tice
- Division of Cardiology, Ohio State University College of Medicine, Columbus
| | | | | | | | | | | | | |
Collapse
|
50
|
Binkley PF, Van Fossen DB, Nunziata E, Unverferth DV, Leier CV. Influence of positive inotropic therapy on pulsatile hydraulic load and ventricular-vascular coupling in congestive heart failure. J Am Coll Cardiol 1990; 15:1127-35. [PMID: 2312969 DOI: 10.1016/0735-1097(90)90253-l] [Citation(s) in RCA: 57] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The aortic input impedance spectrum provides a description of the total hydraulic load imposed on the left ventricle and may be used to assess the coupling of the ventricle to the vasculature. The adaptation of the vasculature to positive inotropic intervention was examined in 10 patients with idiopathic dilated cardiomyopathy to test the hypothesis that increased myocardial contractility is matched by complementary changes in aortic impedance that optimize ventricular-vascular coupling and maximize power transfer to the circulation. High fidelity intravascular recordings of aortic pressure and flow were obtained at baseline study and during infusion of dobutamine to derive the aortic input impedance spectrum. In eight patients in whom increased staged infusion of dobutamine resulted in a significant increase in stroke volume (22.3 +/- 14.5 ml/beat increase over baseline), the significant (p less than 0.05) increase in the maximum of the first derivative left ventricular pressure pulse (dP/dt) was accompanied by significant decreases in characteristic impedance of the aorta (138 +/- 88 to 92 +/- 44 dyne.s.cm-5) wave reflection index (238 +/- 144 to 109 +/- 59 dyne.s.cm-5), and low frequency moduli of impedance. Effective positive inotropic therapy with dobutamine in the setting of congestive heart failure is accompanied by complementary changes in the aortic impedance spectrum, which represent a matching of impedance to the increased contractile state of the ventricle and facilitation of ventricular-vascular coupling.
Collapse
Affiliation(s)
- P F Binkley
- Department of Medicine, Ohio State University, Columbus
| | | | | | | | | |
Collapse
|