1
|
Harbrecht A, Hackl M, Ott N, Uschok S, Wegmann K, Müller LP, Leschinger T. Mayo classification of olecranon fractures revisited - Assessment of intra- and interobserver reliability based on CT scans. J Orthop 2024; 52:102-106. [PMID: 38440410 PMCID: PMC10909575 DOI: 10.1016/j.jor.2024.02.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2024] [Accepted: 02/19/2024] [Indexed: 03/06/2024] Open
Abstract
Purpose Olecranon fractures are classified using the commonly accepted Mayo classification. Its reliability has been analyzed by means of radiographs. A CT scan is often obtained due to joint involvement. Purpose of this study was to evaluate the intra- and interobserver reliability of the Mayo classification based on CT examination. Methods Radiographic and CT images of 20 olecranon fractures were classified by four surgeons at two time points 30 days apart. Intra- and interobserver reliability were assessed using kappa coefficients. Results Mean intraobserver reliability between X-rays was substantial and between CTs almost perfect (0.76 and 0.82, respectively). Mean interobserver reliability was fair for X-rays and moderate for CTs (0.32 and 0.44, respectively). Conclusion Despite the more detailed imaging compared with radiography only moderate interobserver reliability was found for the classification of olecranon fractures based on CT imaging. This might lead to inconsistent fracture classification in both scientific and clinical setting.
Collapse
Affiliation(s)
- Andreas Harbrecht
- University of Cologne, Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, Kerpener Str. 62, 50937, Cologne, Germany
| | - Michael Hackl
- University of Cologne, Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, Kerpener Str. 62, 50937, Cologne, Germany
| | - Nadine Ott
- University of Cologne, Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, Kerpener Str. 62, 50937, Cologne, Germany
| | - Stephan Uschok
- University of Cologne, Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, Kerpener Str. 62, 50937, Cologne, Germany
| | - Kilian Wegmann
- University of Cologne, Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, Kerpener Str. 62, 50937, Cologne, Germany
- Orthopädische Chirurgie München, Munich, Germany
| | - Lars P. Müller
- University of Cologne, Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, Kerpener Str. 62, 50937, Cologne, Germany
| | - Tim Leschinger
- University of Cologne, Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, Kerpener Str. 62, 50937, Cologne, Germany
| |
Collapse
|
2
|
Przyklenk A, Hackl M, Leschinger T, Ott N, Harbrecht A, Müller LP, Wegmann K. Comprehensive analysis and classification of retrocondylar ulnar groove morphology using CT imaging in an average population of adults. Surg Radiol Anat 2024; 46:473-482. [PMID: 38329521 PMCID: PMC10995007 DOI: 10.1007/s00276-024-03297-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Accepted: 01/03/2024] [Indexed: 02/09/2024]
Abstract
PURPOSE Anatomical variations of the concave shaped retrocondylar ulnar groove (RUG) can contribute to ulnar nerve instability. However, there are currently limited available standardized data describing the anatomy of the RUG based on radiologic imaging, such as computed tomography (CT). This study aims to provide a comprehensive description and classification of RUG anatomy based on RUG angle measurements. METHODS 400 CT scans of the elbows of adults showing no signs of osseous damage were evaluated. RUG angles were measured in four anatomically defined axial planes that spanned from the proximal to the distal end of the RUG. Furthermore, distance measurements at the medial epicondyle were conducted. A classification system for the RUG is proposed based on the acquired RUG angles, aiming to categorize the individual angles according to the 25th and 75th percentiles. RESULTS RUG angles were significantly larger in males compared to females (p < 0.001) accompanied by larger distances including the off-set and height of the medial epicondyle (p < 0.001). RUG angles decreased from proximal to distal locations (p < 0.05). CONCLUSION This study revealed that men exhibited larger RUG angles compared to women, indicating a less-concave shape of the RUG in men. Introducing an objective RUG classification system can improve our understanding of anatomical variations and potentially find application in diagnostics and preoperative planning.
Collapse
Affiliation(s)
- Axel Przyklenk
- Department of Orthopedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany.
| | - Michael Hackl
- Department of Orthopedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Tim Leschinger
- Department of Orthopedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Nadine Ott
- Department of Orthopedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Andreas Harbrecht
- Department of Orthopedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Lars Peter Müller
- Department of Orthopedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| | - Kilian Wegmann
- Department of Orthopedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany
| |
Collapse
|
3
|
Lappen S, Siebenlist S, Leschinger T, Kadantsev P, Geyer S, Wegmann K, Müller LP, Hackl M. The importance of interdigitating screw fixation of the trochlea in double plate osteosynthesis of low transcondylar distal humerus fractures: A biomechanical study. Injury 2024; 55:111486. [PMID: 38447478 DOI: 10.1016/j.injury.2024.111486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 02/05/2024] [Accepted: 02/25/2024] [Indexed: 03/08/2024]
Abstract
OBJECTIVE The trochlea is of great importance for the stability of the elbow and its fixation in low transcondylar fractures of the distal humerus is especially challenging. The aim of this study was to determine the optimal trochlea fixation in double plate osteosynthesis of intraarticular distal humerus fractures. METHODS A low transcondylar, C3-type distal humerus fracture was created in 20 fresh-frozen human cadaveric humeri. The samples were then randomly divided into two groups of 10 specimens each. Double plate osteosynthesis was performed in both groups. In group A, the two most distal screws of the lateral plate were inserted into the trochlea fragment. In group B, these screws did not extend into the trochlea. Displacement under cyclic loading and ultimate failure loads were determined for all specimens. RESULTS Group A showed significantly less displacement under cyclic loading in each measurement interval (0.92 mm vs. 1.53 mm after 100 cycles, p = 0 0.006; 1.10 mm vs. 1.84 mm after 1000 cycles, p = 0.007; 1.18 mm vs. 1.98 mm after 2000 cycles, p = 0.008). The ultimate failure load was significantly higher in group A than in group B (345.61 ± 120.389 N vs. 238.42 ± 131.61 N, p = 0.037). CONCLUSIONS Fixation of the trochlea with interdigitating screws in double plate osteosynthesis of low-condylar type C distal humerus fractures results in superior construct stability. LEVEL OF EVIDENCE not applicable (biomechanical).
Collapse
Affiliation(s)
- Sebastian Lappen
- Department of Sports Orthopeadics, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany.
| | - Sebastian Siebenlist
- Department of Sports Orthopeadics, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| | - Tim Leschinger
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Cologne, Germany
| | - Pavel Kadantsev
- Department of Sports Orthopeadics, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany
| | - Stephanie Geyer
- Department of Sports Orthopeadics, Technical University of Munich, Klinikum rechts der Isar, Munich, Germany; Department for Orthopedics, St. Vinzenz Klinik, Pfronten, Germany
| | - Kilian Wegmann
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Cologne, Germany; OCM (Orthopädische Chirurgie München) Clinic, München, Germany
| | - Lars-Peter Müller
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Cologne, Germany
| | - Michael Hackl
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Cologne, Germany
| |
Collapse
|
4
|
Wegmann S, Hackl M, Krane F, Wegmann K, Mueller LP, Leschinger T. Accessibility of osteochondral lesion at the capitellum during elbow arthroscopy: an anatomical study. Arch Orthop Trauma Surg 2024; 144:1297-1302. [PMID: 38172435 PMCID: PMC10896769 DOI: 10.1007/s00402-023-05172-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Accepted: 12/03/2023] [Indexed: 01/05/2024]
Abstract
INTRODUCTION Osteochondrosis dissecans (OCD) at the capitellum is a common pathology in young patients. Although arthroscopic interventions are commonly used, there is a lack of information about the accessibility of the defects during elbow arthroscopy by using standard portals. MATERIALS AND METHODS An elbow arthroscopy using the standard portals was performed in seven fresh frozen specimens. At the capitellum, the most posterior and anterior cartilage surface reachable was marked with K-wires. Using a newly described measuring method, we constructed a circular sector around the rotational center of the capitellum. The intersection of K-wire "A" and "B" with the circular sector was marked, and the angles between the K-wires and the Rogers line, alpha angle for K-Wire "A" and beta angle for K-wire "B", and the corridor not accessible during arthroscopy was digitally measured. RESULTS On average, we found an alpha angle of 53° and a beta angle of 104°. Leaving a sector of 51° which was not accessible via the standard portals during elbow arthroscopy. CONCLUSION Non-accessible capitellar lesions during elbow arthroscopy should be considered preoperatively, and the informed consent discussion should always include the possibility of open procedures or the use of flexible instruments. LEVEL OF EVIDENCE: 4
Collapse
Affiliation(s)
- S Wegmann
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University Hospital of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
| | - M Hackl
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University Hospital of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - F Krane
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University Hospital of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - K Wegmann
- OCM (Orthopädische Chirurgie München) Clinic, Steinerstr. 6, 81369, Munich, Germany
| | - L-P Mueller
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University Hospital of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - T Leschinger
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University Hospital of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| |
Collapse
|
5
|
Ott N, Hackl M, Van Parys M, Leschinger T, Wegmann K, Müller LP. Distal Triceps Rupture with an Injury of the Medial Ulnar Collateral Ligament: a Result of a Fall Onto an Outstretched Arm - a Case Series. Z Orthop Unfall 2024; 162:79-84. [PMID: 35926766 DOI: 10.1055/a-1865-0033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Traumatic triceps tendon ruptures are rare and known to result in substantial disability unless appropriate surgical treatment is performed. A traumatic rupture can occur due to a fall onto the outstretched hand. Tearing of the triceps tendon results in a valgus load onto the elbow, which can lead to injuries to the radial head/neck and/or the ulnar collateral ligament. Hence, attention must be paid to associated pathologies after diagnosis of rupture to the distal triceps tendon. Our surgical procedure in these cases includes diagnostic arthroscopy to detect concomitant injuries. In the following, we present three cases where we performed an open suture bridge repair of the triceps tendon followed by suture repair of the ulnar collateral ligament. All patients recovered well and reported no elbow pain or limited range of motion. The ASES and Mayo Elbow Performance scores were 100 at the 1-year follow-up.
Collapse
Affiliation(s)
- Nadine Ott
- Department of Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital Cologne, Köln, Germany
| | - Michael Hackl
- Department of Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital Cologne, Köln, Germany
| | | | - Tim Leschinger
- Department of Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital Cologne, Köln, Germany
| | - Kilian Wegmann
- Department of Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital Cologne, Köln, Germany
- -, Orthopädische Chirurgie München (OCM), München, Germany
| | - Lars Peter Müller
- Department of Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital Cologne, Köln, Germany
| |
Collapse
|
6
|
Harbrecht A, Hackl M, Leschinger T, Krane F, Müller LP, Wegmann K. Do We Need a Strictly Lateral Radiograph for Fracture Management of Forearm Buckle Fractures in Children? Pediatr Emerg Care 2024; 40:2-5. [PMID: 36898049 DOI: 10.1097/pec.0000000000002924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/12/2023]
Abstract
OBJECTIVES Buckle fractures of the distal forearm are a common fracture entity in children treated conservatively. Diagnostics primarily include radiographs in 2 planes. Inadequate images may occur in the mostly very young patients. Therefore, additional lateral radiographs are often obtained to assess a possible angular tilt. The aim of this study is to investigate whether a strictly lateral x-ray image has an influence on fracture management. METHODS Seventy-three children with buckle fractures of the distal forearm were included in this retrospective analysis. All cases were analyzed by quality of radiographs, necessity to obtain an additional lateral radiograph, and what influence on fracture management resulted. Follow-up was performed 2 to 4 weeks after immobilization. RESULTS Thirty-five girls and 38 boys with a mean age of 7.16 years were included; 40 had fractured right and 33 had fractured left arms, respectively. Isolated distal radius fractures occurred in 48 cases, isolated distal ulna fractures in 6 cases, and both bones in 19 cases. Initial radiographic images were evaluated as inadequate in 25 cases. In each of those cases, an additional lateral image was obtained by fluoroscopy without resulting in an alternated fracture management protocol, which was chosen conservatively in each case and resulted in excellent clinical outcome at follow-up examination. CONCLUSIONS Based on our results, the acquisition of additional lateral radiographs seems to be unnecessary in the diagnostic procedure of buckle fractures of the distal forearm, in case a possible palmar or dorsal angulation cannot be entirely assessed on the initial set of radiographs. An additional lateral image had no influence on fracture management, which was chosen conservatively in every case and led to excellent clinical results.Level of evidence: level III.
Collapse
Affiliation(s)
- Andreas Harbrecht
- From the Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Cologne, Germany
| | | | | | | | | | | |
Collapse
|
7
|
Sircar K, Kernich N, Scaal M, Eysel P, Müller LP, Leschinger T. Morphometrics of the coronoid process and the radial notch of the ulna: implications for fracture assessment. Surg Radiol Anat 2023; 45:1587-1592. [PMID: 37837464 PMCID: PMC10625508 DOI: 10.1007/s00276-023-03249-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2023] [Accepted: 09/25/2023] [Indexed: 10/16/2023]
Abstract
PURPOSE A comprehensive analysis of the morphology of fractures of the coronoid process (CP) can aid diagnosis and guide treatment. The involvement of the radial notch of the ulna (RN)-e.g., in anterolateral facet fractures and transverse fractures of the CP-may influence the biomechanical conditions of the proximal radioulnar joint. However, the morphometric relation between the CP and the RN and the extent to what the proximal radioulnar joint can be affected in these types of fractures is unknown. METHODS A total of 113 embalmed, cadaveric ulnae were dissected. All soft tissue was removed. Strictly lateral, high-resolution photographs were taken and digitally analyzed. The height of the CP and its relation to the RN was measured. Sex differences and correlations between measured parameters were calculated. RESULTS Mean height of the CP was 16 mm (range: 12-23 mm; SD: 2). Mean height of the RN was 16 mm (11-25 mm; 2.2). The 50% mark of the CP corresponded to 18% (0-56%; 11.2) of the height of the RN. No significant differences were found between male and female specimens. CONCLUSION The RN of the ulna extends only to a small part to the CP. Transverse or anterolateral fractures of less than 50% of the coronoid process may involve only a small portion of the proximal radioulnar joint.
Collapse
Affiliation(s)
- Krishnan Sircar
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener-Strasse 62, 50937, Cologne, Germany.
| | - Nikolaus Kernich
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener-Strasse 62, 50937, Cologne, Germany
| | - Martin Scaal
- Faculty of Medicine, Institute of Anatomy II, University of Cologne, Joseph-Stelzmann Str. 9, 50937, Cologne, Germany
| | - Peer Eysel
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener-Strasse 62, 50937, Cologne, Germany
| | - Lars-Peter Müller
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener-Strasse 62, 50937, Cologne, Germany
| | - Tim Leschinger
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener-Strasse 62, 50937, Cologne, Germany
| |
Collapse
|
8
|
Leyendecker J, Hackl M, Leschinger T, Bredow J, Krane F, Eysel P, Müller LP, Harbrecht A. Lessons learned? Increasing injury severity of electric-scooter accidents over a period of one year: a monocentric follow-up study at a level 1 trauma center. Eur J Orthop Surg Traumatol 2023; 33:3643-3648. [PMID: 37268872 PMCID: PMC10238235 DOI: 10.1007/s00590-023-03583-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Accepted: 05/10/2023] [Indexed: 06/04/2023]
Abstract
PURPOSE After major COVID-19 lockdown measures were suspended in 2021, E-scooter mobility regrew rapidly. In the meantime, multiple studies were published on the potential risks for e-scooter drivers and the necessity for wearing protective equipment. But did the drivers learn their lessons? METHODS We observed data of E-scooter-related accidents admitted to the emergency department of a level 1 German trauma center in the year 2021 and compared the data with our previous report (July 2019-July 2020). RESULTS N = 97 E-scooter-related accidents were included, marking a 50% increase when compared to the previous observation. Most patients were young adults (28.18 ± 1.13 years) with a notable shift towards a male population (25 vs. 63, p = 0.007). While the injury pattern remained unchanged, injury severity, reflected by a significant increase in shock room treatments (p = 0.005), hospital admissions (p = 0.45), and ICU admissions (p = 0.028), increased. Lastly, we report a higher injury severity of patients driving under the influence of alcohol, expressed by significant differences in hospital admissions, shock room treatments, ICU admissions, intracerebral bleeding (p < 0.0001), and injuries requiring surgery (p = 0.0017). CONCLUSION The increase in injury severity and especially the substantial number of accidents due to driving under the influence of alcohol, are alarming for both trauma- and neurosurgeons. As the controversy surrounding the general use of E-scooters will continue, we urge representatives to intensify their efforts regarding prevention campaigns focusing on the potential dangers of E-scooters, especially when driving under the influence of alcohol.
Collapse
Affiliation(s)
- Jannik Leyendecker
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
- Department of Neurological Surgery, University of Washington, Seattle, WA, USA.
| | - Michael Hackl
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Tim Leschinger
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Jan Bredow
- Department of Orthopedics and Trauma Surgery, Krankenhaus Porz Am Rhein, University of Cologne, Cologne, Germany
| | - Felix Krane
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Peer Eysel
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Lars P Müller
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Andreas Harbrecht
- Department of Orthopedics and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| |
Collapse
|
9
|
Messler V, Leschinger T, Ott N, Rausch V, Burst V, Eysel P, Müller LP, Hackl M. The impact of the SARS-CoV-2 pandemic-related lockdowns on orthopedic trauma emergencies at a level-one trauma center. Arch Orthop Trauma Surg 2023; 143:6201-6208. [PMID: 37341804 PMCID: PMC10491551 DOI: 10.1007/s00402-023-04947-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Accepted: 06/11/2023] [Indexed: 06/22/2023]
Abstract
INTRODUCTION The SARS-CoV-2 pandemic and its associated lockdowns had a profound effect on orthopedic trauma emergencies. This study aimed to investigate the patient volume and injury patterns at a level-one trauma center during the SARS-CoV-2 pandemic and compare them to the pre-pandemic conditions. MATERIALS AND METHODS A retrospective chart review of all patients who presented to the orthopedic trauma emergency department of a level-one trauma center in Cologne, Germany within a 2 year period from March 16th, 2019 to March 15th, 2020 (pre-pandemic control) and from March 16th, 2020 and March 15th, 2021 (pandemic) was performed. The pandemic year was separated into three periods: (1) first lockdown, (2) between lockdowns and (3) second lockdown. The absolute numbers of patient presentations, the Manchester triage score (MTS) and the relative proportion of patients with structural organ injuries, fractures and dislocations, of polytraumatized patients, of hospital admissions, of subsequent emergency or semi-elective surgeries and of work-related accidents were evaluated in comparison to the pre-pandemic control. RESULTS A total of 21,642 patient presentations were included in this study. Significantly less weekly orthopedic trauma emergency patient presentations were recorded during the pandemic (p < 0.01). The MTS was significantly lower during the first lockdown and between lockdowns (p < 0.01). The proportional incidence of overall structural organ injuries, fractures and dislocations, of upper limb fractures/dislocations, of hospital admissions and of patients requiring surgery was significantly increased during the pandemic (p ≤ 0.03). The proportional incidence of work-related injuries was significantly decreased during the pandemic (p < 0.01). CONCLUSIONS Orthopedic trauma emergency presentations were reduced during the SARS-CoV-2 pandemic. Due to the reluctancy of patients to visit the emergency department during the pandemic, the proportions of relevant injuries in general and of upper limb injuries in particular as well as of patients requiring hospital admission and trauma-related surgery were significantly increased.
Collapse
Affiliation(s)
- Valentin Messler
- Faculty of Medicine, University Hospital Cologne, Center of Orthopedic and Trauma Surgery, and University of Cologne, Cologne, Germany
| | - Tim Leschinger
- Faculty of Medicine, University Hospital Cologne, Center of Orthopedic and Trauma Surgery, and University of Cologne, Cologne, Germany
| | - Nadine Ott
- Faculty of Medicine, University Hospital Cologne, Center of Orthopedic and Trauma Surgery, and University of Cologne, Cologne, Germany
| | - Valentin Rausch
- Faculty of Medicine, University Hospital Cologne, Center of Orthopedic and Trauma Surgery, and University of Cologne, Cologne, Germany
| | - Volker Burst
- Emergency Department, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
- Department II of Internal Medicine and Center for Molecular Medicine Cologne, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - Peer Eysel
- Faculty of Medicine, University Hospital Cologne, Center of Orthopedic and Trauma Surgery, and University of Cologne, Cologne, Germany
| | - Lars Peter Müller
- Faculty of Medicine, University Hospital Cologne, Center of Orthopedic and Trauma Surgery, and University of Cologne, Cologne, Germany
| | - Michael Hackl
- Faculty of Medicine, University Hospital Cologne, Center of Orthopedic and Trauma Surgery, and University of Cologne, Cologne, Germany.
| |
Collapse
|
10
|
Weber M, Rahn J, Hackl M, Leschinger T, Dresing K, Müller LP, Wegmann K, Harbrecht A. Postoperative swelling after elbow surgery: influence of a negative pressure application in comparison to manual lymphatic drainage-a randomized controlled trial. Arch Orthop Trauma Surg 2023; 143:6243-6249. [PMID: 37421514 PMCID: PMC10491702 DOI: 10.1007/s00402-023-04954-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 06/18/2023] [Indexed: 07/10/2023]
Abstract
PURPOSE Postoperative soft tissue swelling is a significant factor influencing outcomes after elbow surgery. It can crucially affect important parameters such as postoperative mobilization, pain, and subsequently the range of motion (ROM) of the affected limb. Furthermore, lymphedema is considered a significant risk factor for numerous postoperative complications. Manual lymphatic drainage is nowadays part of the standardized post-treatment concept, basing on the concept of activating the lymphatic tissue to absorb stagnated fluid from the tissue into the lymphatic system. This prospective study aims to investigate the influence of technical device-assisted negative pressure therapy (NP) on early functional outcomes after elbow surgery. NP was therefore compared to manual lymphatic drainage (MLD). Is a technical device-based NP suitable for treatment of lymphedema after elbow surgery? METHODS A total of 50 consecutive patients undergoing elbow surgery were enrolled. The patients were randomized into 2 groups. 25 participants per group were either treated by conventional MLD or NP. The primary outcome parameter was defined as the circumference of the affected limb in cm postoperative up to seven days postoperatively. The secondary outcome parameter was a subjective perception of pain (measured via visual analogue scale, VAS). All parameters were measured on each day of postoperative inpatient care. RESULTS AND CONCLUSION NP showed an overall equivalent influence compared to MLD in reducing upper limb swelling after surgery. Moreover, the application of NP showed a significant decrease in overall pain perception compared to manual lymphatic drainage on days 2, 4 and 5 after surgery (p < 0.05). CONCLUSION Our findings show that NP could be a useful supplementary device in clinical routine treating postoperative swelling after elbow surgery. Its application is easy, effective and comfortable for the patient. Especially due to the shortage of healthcare workers and physical therapists, there is a need for supportive measures which NP could be.
Collapse
Affiliation(s)
- Maximilian Weber
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
| | - Jürgen Rahn
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Michael Hackl
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Tim Leschinger
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Klaus Dresing
- Department of Trauma, Plastic and Reconstructive Surgery, Georg-August-University Göttingen, Robert-Koch-Strasse 40, 37075, Göttingen, Germany
| | - Lars P Müller
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Kilian Wegmann
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Andreas Harbrecht
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| |
Collapse
|
11
|
Hockmann J, Ott N, Leschinger T, Müller LP, Hackl M. [Clinical results of total elbow arthroplasty after treatment failure for Monteggia-like injuries]. Unfallchirurgie (Heidelb) 2023; 126:700-705. [PMID: 37270731 PMCID: PMC10450013 DOI: 10.1007/s00113-023-01335-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 04/24/2023] [Indexed: 06/05/2023]
Abstract
BACKGROUND Monteggia-like fractures (MLF) are complex injuries with high complication rates and frequently unsatisfying clinical results. Total elbow arthroplasty (TEA) represents the only option to salvage the functional requirements in some patients with pronounced posttraumatic arthropathy. This case series provides clinical results of TEA following failed treatment of MLF. METHODS All patients who underwent TEA from 2017 to 2022 for failed treatment of MLF were retrospectively included in this study. Complications and revisions before and after TEA and functional results, measured by the Broberg/Morrey score, were evaluated. RESULTS In this study 9 patients with a mean age of 68 (±7; 54-79) years were included. The mean follow-up was 12 (±9; 2-27) months. The main reasons leading to posttraumatic arthropathy were chronic infections (44.4%), bony instability due to coronoid deficiency (33.3%) or a combined coronoid and radial head deficiency (22.2%) and non-union of the proximal ulna with radial head necrosis (11.1%). The mean number of surgical revisions between primary fixation and TEA was 2.7 (±1.8; 0-6). The revision rate following TEA was 44%. The mean Broberg/Morrey score at the time of the latest follow-up was 83 (±10; 71-97) points. CONCLUSION Chronic infection and coronoid deficiency are the main reasons for posttraumatic arthropathy after MLF leading to TEA. While the overall clinical results are satisfying, the indications should be reserved for selected cases due to high revision rates.
Collapse
Affiliation(s)
- Jan Hockmann
- Universität zu Köln, Medizinische Fakultät und Uniklinik Köln, Klinik für Orthopädie, Unfallchirurgie und Plastische Chirurgie, Kerpener Straße 62, 50937, Köln, Deutschland.
| | - Nadine Ott
- Universität zu Köln, Medizinische Fakultät und Uniklinik Köln, Klinik für Orthopädie, Unfallchirurgie und Plastische Chirurgie, Kerpener Straße 62, 50937, Köln, Deutschland
| | - Tim Leschinger
- Universität zu Köln, Medizinische Fakultät und Uniklinik Köln, Klinik für Orthopädie, Unfallchirurgie und Plastische Chirurgie, Kerpener Straße 62, 50937, Köln, Deutschland
| | - Lars Peter Müller
- Universität zu Köln, Medizinische Fakultät und Uniklinik Köln, Klinik für Orthopädie, Unfallchirurgie und Plastische Chirurgie, Kerpener Straße 62, 50937, Köln, Deutschland
| | - Michael Hackl
- Universität zu Köln, Medizinische Fakultät und Uniklinik Köln, Klinik für Orthopädie, Unfallchirurgie und Plastische Chirurgie, Kerpener Straße 62, 50937, Köln, Deutschland
| |
Collapse
|
12
|
Wegmann S, Ott N, Leschinger T, Hackl M, Müller LP. [Follow-up treatment concepts for elbow injuries]. Unfallchirurgie (Heidelb) 2023; 126:694-699. [PMID: 37278730 DOI: 10.1007/s00113-023-01327-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 04/06/2023] [Indexed: 06/07/2023]
Abstract
So far there are no clear recommendations for postoperative follow-up treatment of elbow injuries and individual concepts are often chosen. Due to the susceptibility for posttraumatic or postoperative impaired movement up to stiffness of the elbow joint, early mobilization plays a crucial role. Therefore, mid-term to long-term immobilization should be avoided. In addition to the necessary cryotherapy and compression therapy for swelling and pain control in the initial period, early actively assisted mobilization now has an important role. Additionally, active flexion and extension in an overhead position, so-called overhead motion, was recently established. After a short initial immobilization in a cast, mostly 3-5 days, the cast is changed to a dynamic movement orthosis, which when possible enables a free range of motion. Care is taken that varus and valgus loading is avoided. In general loading is avoided for the first 6 weeks, followed by a stepwise increase of loading up to maximum loading. In most cases return to sport is possible after 3 months. After implantation of an elbow prosthesis a maximum loading of 5 kg for single loading and 1 kg for repetitive loading are recommended.
Collapse
Affiliation(s)
- Sebastian Wegmann
- Klinik und Poliklinik für Orthopädie, Unfallchirurgie und Plastisch-Ästhetische Chirurgie, Uniklinik Köln, Kerpener Straße 62, 50937, Köln, Deutschland.
| | - Nadine Ott
- Klinik und Poliklinik für Orthopädie, Unfallchirurgie und Plastisch-Ästhetische Chirurgie, Uniklinik Köln, Kerpener Straße 62, 50937, Köln, Deutschland
| | - Tim Leschinger
- Klinik und Poliklinik für Orthopädie, Unfallchirurgie und Plastisch-Ästhetische Chirurgie, Uniklinik Köln, Kerpener Straße 62, 50937, Köln, Deutschland
| | - Michael Hackl
- Klinik und Poliklinik für Orthopädie, Unfallchirurgie und Plastisch-Ästhetische Chirurgie, Uniklinik Köln, Kerpener Straße 62, 50937, Köln, Deutschland
| | - Lars Peter Müller
- Klinik und Poliklinik für Orthopädie, Unfallchirurgie und Plastisch-Ästhetische Chirurgie, Uniklinik Köln, Kerpener Straße 62, 50937, Köln, Deutschland
| |
Collapse
|
13
|
Ott N, Hackl M, Leschinger T, Müller LP. [Monteggia-like injuries : Pitfalls of surgical treatment]. Unfallchirurgie (Heidelb) 2023; 126:687-693. [PMID: 37278731 DOI: 10.1007/s00113-023-01328-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 04/06/2023] [Indexed: 06/07/2023]
Abstract
The term Monteggia-like lesions or Monteggia equivalent injuries includes fractures of the proximal ulna with dislocation and dislocation fractures of the radial head from the proximal radio-ulnar joint. The complexity of the injury requires a dedicated understanding of the anatomical structures and their biomechanical properties. Particularly due to the rarity, the complication and revision rates are high. A conservative treatment is not usually effective. Three-dimensional imaging by computed tomography is part of the surgical preparation. The goal of surgical treatment is osteosynthetic reconstruction of the fractures and restoration of joint congruency. In cases of nonreconstructable radial head fractures, radial head arthroplasty may be necessary. In addition to reconstruction of the bony stabilizers, refixation of the ligamentous structures is essential for treatment success. The combination of complex fracture patterns and possible dislocation positions in the ulnohumeral, radiohumeral and proximal radio-ulnar joints poses a great challenge to the surgeon. The most frequent complications are peri-implant infections, implant failure, loss of reduction, stiffness or instability. Especially the anatomical configuration of the proximal ulna is complex and requires accurate reconstruction. Therefore, reconstruction of the proximal ulna in length and rotation, including the coronoid process, is considered to be a key factor in the surgical treatment of Monteggia-like injuries.
Collapse
Affiliation(s)
- Nadine Ott
- Medizinische Fakultät und Uniklinik Köln, Klinik für Orthopädie, Unfallchirurgie und plastisch-ästhetische Chrirugie, Universität zu Köln, 50937, Köln, Deutschland.
| | - Michael Hackl
- Medizinische Fakultät und Uniklinik Köln, Klinik für Orthopädie, Unfallchirurgie und plastisch-ästhetische Chrirugie, Universität zu Köln, 50937, Köln, Deutschland
| | - Tim Leschinger
- Medizinische Fakultät und Uniklinik Köln, Klinik für Orthopädie, Unfallchirurgie und plastisch-ästhetische Chrirugie, Universität zu Köln, 50937, Köln, Deutschland
| | - Lars Peter Müller
- Medizinische Fakultät und Uniklinik Köln, Klinik für Orthopädie, Unfallchirurgie und plastisch-ästhetische Chrirugie, Universität zu Köln, 50937, Köln, Deutschland
| |
Collapse
|
14
|
Camenzind RS, Cucchi D, Leschinger T, Hackl M, Müller LP, Wegmann K. Screw placement in arthroscopically assisted osteosynthesis of radial head fractures using a reference k-wire in the radiocapitellar joint: a cadaveric study. Arch Orthop Trauma Surg 2023; 143:4111-4116. [PMID: 36197491 PMCID: PMC10293376 DOI: 10.1007/s00402-022-04605-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/21/2021] [Accepted: 08/29/2022] [Indexed: 11/02/2022]
Abstract
PURPOSE The optimal screw placement in arthroscopically assisted fixation of radial head fractures is still an issue and no guiding methods have been evaluated in the recent literature. The study hypothesis was that using a "reference k-wire" percutaneously inserted in and parallel to the radiocapitellar joint would enable to achieve a trajectory more parallel to the radial head articular surface as compared to a free-hand k-wire placement. METHODS Arthroscopically assisted placement of a k-wire in the radial head was performed in seven fresh-frozen human cadaver specimens by three surgeons. Three different techniques were evaluated: freehand drilling (technique A), placement using a "reference" k-wire in the radiocapitellar joint as a reference without (technique B), and with the AO parallel k-wire guide (technique C). Radiographs from all procedures were obtained and the inclination angle "α" between the k-wire and the articular surface of the radial head was measured and compared among the techniques. RESULTS Angles of 84 radiographs were obtained and showed a mean α angle of 30.1° ± 13° for technique A, 5.7° ± 4.5° for technique B, and 5.4° ± 3.7° for technique C. The angle α was significantly higher with technique A as compared to B (p < 0.0001) and C (p < 0.0001). There was no difference between methods B and C (n.s.). No difference was observed among the surgeons for all three methods (p = 0.66). CONCLUSION With the use of an additional "reference" k-wire placed in the radiocapitellar joint, the guiding k-wire for screw drilling can be placed almost parallel to the radial head joint line with limited variability and a good reproducibility during arthroscopically assisted radial head fracture fixation. CLINICAL RELEVANCE The here-presented method of an additional, percutaneous introduced "reference" k-wire is easily applicable and helpful to achieve parallel screw placement during arthroscopically assisted radial head fracture fixation. LEVEL OF EVIDENCE IV, biomechanical cadaver study.
Collapse
Affiliation(s)
- Roland S. Camenzind
- Center for Orthopedic and Trauma Surgery, University Hospital Cologne, University of Cologne, Cologne, Germany
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Forchstrasse 340, 8008 Zurich, Switzerland
- Department of Orthopedic and Trauma Surgery, Cantonal Hospital Lucerne, Spitalstrasse, 6000 Lucerne, Switzerland
| | - Davide Cucchi
- Department of Orthopedic and Trauma Surgery, Cantonal Hospital Lucerne, Spitalstrasse, 6000 Lucerne, Switzerland
| | - Tim Leschinger
- Center for Orthopedic and Trauma Surgery, University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Michael Hackl
- Department of Orthopedic and Trauma Surgery, University Hospital Bonn, Sigmund-Freud-Str. 25, 53127 Bonn, Germany
| | - Lars P. Müller
- Center for Orthopedic and Trauma Surgery, University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Kilian Wegmann
- Center for Orthopedic and Trauma Surgery, University Hospital Cologne, University of Cologne, Cologne, Germany
| |
Collapse
|
15
|
Lanzerath F, Knifka J, Leschinger T, Ott N, Kahmann S, Hackl M, Müller LP, Wegmann K. The simulation of terrible triad injuries in fresh-frozen human cadaveric specimens with intact soft tissue envelope. Arch Orthop Trauma Surg 2023; 143:4229-4237. [PMID: 36512058 PMCID: PMC10293332 DOI: 10.1007/s00402-022-04677-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 10/23/2022] [Indexed: 12/15/2022]
Abstract
INTRODUCTION The aim of the present study was to develop a technical process to reproducibly generate terrible triad injuries (TTI) in fresh-frozen human cadaveric specimens, while leaving the skin intact. Such "pre-fractured" specimens, used for scientific analysis and for surgical education, might help to improve current treatment, which is complex and prone to complications. MATERIALS AND METHODS To induce the desired fractures, a custom-made fracturing unit was used to apply an axial force on the extended cadaveric elbow specimens, with the forearm pronated and under valgus load. To simulate the valgus load, a pneumatic cylinder was developed to apply valgus stress to the joint by an additional force vector from the lateral side of the joint. RESULTS The success rate of TTI induction was 92.3% (12/13). Of the 12 radial head fractures, 3 (25%) were classified Mason type II and 9 (75%) Mason type III. The coronoid fractures were grouped in tip subtype 2 (5 fractures, 41.7%), anteromedial facet (AMF) subtype 2 (4 fractures, 33.3%), AMF subtype 3 (1 fracture, 8.3%) and basal subtype 1 (2 fractures, 16.7%). CONCLUSIONS The present study provides an instrument for successful and reproducible production of dislocation fracture patterns with their typical accompanying soft tissue lesions. The methodology might be applied on a broad basis to be able to perform biomechanical studies regarding primary stability of fixation concepts for TTI and to educate surgeons in a fairly realistic scenario with the surgical treatment of TTI.
Collapse
Affiliation(s)
- Fabian Lanzerath
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.
- Department of Anatomy I, Medical Faculty, University of Cologne, Cologne, Germany.
| | - Jutta Knifka
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
- Department of Anatomy I, Medical Faculty, University of Cologne, Cologne, Germany
| | - Tim Leschinger
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Nadine Ott
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Stephanie Kahmann
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Michael Hackl
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Lars P Müller
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Kilian Wegmann
- OCM (Orthopädische Chirurgie München) Clinic, Munich, Germany
| |
Collapse
|
16
|
Lanzerath F, Wegmann K, Hackl M, Uschok S, Ott N, Müller LP, Leschinger T. Surgical arthrolysis of the stiff elbow: a systematic review. Arch Orthop Trauma Surg 2023; 143:2383-2393. [PMID: 35482109 PMCID: PMC10110632 DOI: 10.1007/s00402-022-04442-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Accepted: 04/05/2022] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Stiffness after elbow injuries can severely limit daily life. If adequate conservative treatment does not result in satisfactory improvement of elbow function, surgical intervention should be considered. Whether an open or arthroscopic procedure is preferable is still a topic of debate and a systematic review of functional outcomes is lacking. MATERIALS AND METHODS We systematically reviewed the available literature searching electronic databases, MEDLINE using the PubMed interface and EMBASE, for studies published between 2013 and 2021. Primary objective was to compare open and arthroscopic arthrolysis' functional outcomes, respectively, especially ROM and MEPS, as well as the accompanied complications. The PRISMA guidelines were applied. RESULTS 27 studies comprising 1666 patients were included. 1059 patients (63.6%) were treated with open arthrolysis, and 607 patients (36.4%) were treated with arthroscopic arthrolysis. The results presented indicate satisfactory outcomes in open and arthroscopic arthrolysis with regard to functional outcome parameters. Treatment success, defined as excellent or good results according to the Mayo Elbow Performance Score, among the patients treated with an open procedure was 88.8%; 6.3% required revision whereas 18.1% had complications without the need for revision surgery. Within the cohort of arthroscopically treated patients, treatment success was 91.8%. Revisions and complications without further surgical intervention were significantly less frequent than in the open cohort, at 1.6% and 9.1%, respectively. CONCLUSIONS Both open and arthroscopic arthrolysis provide good to excellent functional outcomes. Since the number of complications and revision increases with the invasiveness of the treatment, an arthroscopic procedure might be favored if feasible by indication. The role of forearm rotation and the use of a hinged external fixator remains of interest. STUDY DESIGN Level IV; Systematic review.
Collapse
Affiliation(s)
- Fabian Lanzerath
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.
| | - Kilian Wegmann
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Michael Hackl
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Stephan Uschok
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Nadine Ott
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Lars P Müller
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - Tim Leschinger
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| |
Collapse
|
17
|
Lanzerath F, Hochberger F, Ott N, Hackl M, Wegmann K, Müller LP, Leschinger T. Anteromedial coronoid facet fractures and associated ligament lesions: A case series. Injury 2023:S0020-1383(23)00368-6. [PMID: 37100696 DOI: 10.1016/j.injury.2023.04.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 04/11/2023] [Accepted: 04/13/2023] [Indexed: 04/28/2023]
Abstract
INTRODUCTION Varus posteromedial rotational injury mechanisms lead to fractures of the coronoids process' anteromedial facet. As these fractures are often unstable, rapid fracture treatment is vital to prevent progressive osteoarthritis. MATERIALS AND METHODS Twelve patients with a fracture of the anteromedial facet treated surgically were enrolled in the study. Computed tomography images were used to classify the fractures according to the system by O'Driscoll et al. Clinical follow-up included each patient's medical record, surgical treatment algorithm, all complications encountered during the follow-up period, Disabilities of the arm, shoulder, and hand score, subjective elbow value, and pain. RESULTS A total of 8 men (66.7%) and 4 women (33.3%) were treated surgically and followed-up after a mean period of 45 ± 23 months. The mean DASH score was 11.9 ± 12.9 points. One patient complained of transient neuropathy in the innervation area of the ulnar nerve, however, this existed already pre-operatively and resolved after less than three months. CONCLUSIONS The presented patient cohort shows that AMF fracture of the coronoid process are unstable lesions according to the bony instability and the frequently ruptured collateral ligament complexes which need to be addressed. The MCL seems to be affected more frequently than previously appreciated. LEVEL OF EVIDENCE Level IV; Case Series; Treatment Study.
Collapse
Affiliation(s)
- Fabian Lanzerath
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, Cologne 50937, Germany.
| | - Felix Hochberger
- Abteilung und Poliklinik für Sportorthopädie, Klinikum Rechts der Isar, Technische Universität München, Munich, Germany
| | - Nadine Ott
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, Cologne 50937, Germany
| | - Michael Hackl
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, Cologne 50937, Germany
| | - Kilian Wegmann
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, Cologne 50937, Germany; OCM (Orthopädische Chirurgie München) Clinic, München, Germany
| | - Lars P Müller
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, Cologne 50937, Germany
| | - Tim Leschinger
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, Cologne 50937, Germany
| |
Collapse
|
18
|
Przyklenk A, Hackl M, Iuga AI, Leschinger T, Maintz D, Harbrecht A, Müller LP, Wegmann K. Computed tomography-based angle measurements of the sagittal capitulum and trochlea position in relation to the humeral shaft. Surg Radiol Anat 2023; 45:571-580. [PMID: 36892617 PMCID: PMC10130112 DOI: 10.1007/s00276-023-03118-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Accepted: 02/22/2023] [Indexed: 03/10/2023]
Abstract
The radiologic evaluation of the sagittal angulation of the distal humerus is commonly based on standard lateral radiographs. However, lateral radiographs do not allow to examine the lateral angulation of the capitulum and the trochlea, separately. Although this problem could be approached via computed tomography, there are no data available describing the difference between the angulation of the capitulum and trochlea. Therefore, we aimed to assess sagittal angles of the capitulum and trochlea in relation to the humeral shaft based on 400 CT-scans of the elbow in healthy adults. Angles were measured in sagittal planes at the capitulum center and three anatomically defined trochlea locations and were spanned between the axis of the joint component and the humerus shaft. Angles were tested for differences between measurement locations and correlation with patient characteristics (age, sex, trans-epicondylar distance). Angles increased from lateral to medial measurement locations (107.4 ± 9.6°, 167.4 ± 8.2°, 171.8 ± 7.3°, 179.1 ± 7.0°; p < 0.05). Largest angle differences were detected between the capitulum and trochlea with smallest angles measured at the capitulum. Patient characteristics did not correlate with angles (p > 0.05). Intra-rater-reliability was r = 0.79-0.86. As CT-imaging allows to distinguish between sagittal capitulum and trochlea locations, it might benefit the radiologic diagnostic of sagittal malalignments of the distal humerus at the capitulum and trochlea, separately.
Collapse
Affiliation(s)
- Axel Przyklenk
- Department of Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany.
| | - Michael Hackl
- Department of Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - Andra-Iza Iuga
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - Tim Leschinger
- Department of Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - David Maintz
- Institute of Diagnostic and Interventional Radiology, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - Andreas Harbrecht
- Department of Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - Lars Peter Müller
- Department of Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| | - Kilian Wegmann
- Department of Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital Cologne, Cologne, Germany
| |
Collapse
|
19
|
Ott N, Harland A, Lanzerath F, Leschinger T, Hackl M, Wegmann K, Müller LP. Locking suture repair versus ligament augmentation-a biomechanical study regarding the treatment of acute lateral collateral ligament injuries of the elbow. Arch Orthop Trauma Surg 2023; 143:857-863. [PMID: 35064826 PMCID: PMC9925465 DOI: 10.1007/s00402-022-04337-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2021] [Accepted: 01/01/2022] [Indexed: 11/24/2022]
Abstract
BACKGROUND Lateral collateral ligament (LCL) tears are frequently observed in fractures and dislocations of the elbow. Recent biomechanical evidence suggests that additional ligament augmentation may improve repair stability. The aim of this biomechanical in-vitro study was to compare the resistance of a locking suture repair of the LCL with a ligament augmentation technique. MATERIAL AND METHODS Eight fresh frozen cadaveric elbows were evaluated for stability against varus/posterolateral rotatory forces (3 Nm). A strain gauge (µm/m; negative values) was placed at the origin and insertion of the lateral ulnar collateral ligament (LUCL) and cyclic loading was performed for 1000 cycles. We analyzed three distinct scenarios: (A) native LCL, (B) locking transosseou suture repair of the LCL, (C) simple LCL repair with additional ligament augmentation of the LUCL. RESULTS The mean measured strain was - 416.1 µm/m (A), - 618 µm/m (B) and - 288.5 µm/m (C) with the elbow flexion at 90°; the strain was significantly higher in scenario B compared to C (p = .01). During the cyclic load (1000) the mean measured strain was - 523.1 µm/m (B) and - 226.3 µm/m (C) with the elbow flexion at 60°; the strain was significantly higher in scenario B compared to C (p = .01). No significant difference between the first and the last cycles was observed (p = .09; p = .07). One failure of the LCL repair was observed after 1000 cycles; none of the ligament augmentations failed. CONCLUSION Ligament augmentation (C) provides higher resistance compared to the native LCL (A) and to the locking suture repair technique (B). Both techniques, however, hold up during 1000 cycles. While ligament augmentation might enhance the primary stability of the repair, future clinical studies have to show whether this increase in resistance leads to negative effects like higher rates of posttraumatic elbow stiffness. LEVEL OF EVIDENCE Basic science study, biomechanics.
Collapse
Affiliation(s)
- Nadine Ott
- Department of Trauma and Orthopedic Surgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, Kerpener Street 62, 50937, Cologne, Germany.
| | - Arne Harland
- Department of Trauma and Orthopedic Surgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, Kerpener Street 62, 50937 Cologne, Germany
| | - Fabian Lanzerath
- Department of Trauma and Orthopedic Surgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, Kerpener Street 62, 50937 Cologne, Germany
| | - Tim Leschinger
- Department of Trauma and Orthopedic Surgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, Kerpener Street 62, 50937 Cologne, Germany
| | - Michael Hackl
- Department of Trauma and Orthopedic Surgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, Kerpener Street 62, 50937 Cologne, Germany
| | - Kilian Wegmann
- Department of Trauma and Orthopedic Surgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, Kerpener Street 62, 50937 Cologne, Germany
| | - Lars Peter Müller
- Department of Trauma and Orthopedic Surgery, University Hospital Cologne and Faculty of Medicine, University of Cologne, Kerpener Street 62, 50937 Cologne, Germany
| |
Collapse
|
20
|
Egenolf P, Hackl M, Leschinger T, Harbrecht A, Ott N, Müller LP, Wegmann K. Optimal K-Wire Placement for Indirect Cannulated Screw Fixation of Coronoid Process Fractures: A Radiology-Based Guide. J Hand Surg Am 2022:S0363-5023(22)00608-6. [PMID: 36400651 DOI: 10.1016/j.jhsa.2022.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2022] [Revised: 09/13/2022] [Accepted: 10/05/2022] [Indexed: 11/17/2022]
Abstract
PURPOSE Indirect fixation of coronoid process fractures of the ulna, especially arthroscopically, offers the possibility to avoid extensive medial surgical approaches. However, optimal placement of K-wires for cannulated screw fixation is technically challenging. The aim of the present study was to present guide values for K-wire placement for indirect screw fixation of coronoid tip (COT) and anteromedial facet (AMF) fractures of the ulna. METHODS Computed tomography scans of the elbows of 197 patients with an uninjured ulna were identified and evaluated following a standard measuring protocol. Optimal placement of K-wires was defined as the bisector between the anterior and articular cortex while respecting a 1.6-mm safe zone for each placement. This placement of the K-wires in the COT and the AMF was analyzed by measuring the wire angulation in relation to the posterior ulnar cortex (AUC), the distance from the entry point to the posterior olecranon edge (DPE), and the intraosseous length (IOL). Because the coronoid has a curved shape, measurements of the COT and AMF were expected to differ significantly. Sex was also expected to influence measurements. To determine whether this optimal placement of K-wires can be reliably identified, interobserver and intraobserver reliabilities were evaluated. RESULTS To address tip fragments, we determined a mean AUC of 64°, DPE of 36 mm, and IOL of 38 mm. Regarding wire placement toward the AMF, the means for the AUC, DPE, and IOL were 79°, 27 mm, and 33 mm, respectively. Statistically significant differences were found between the COT and the AMF for the AUC, DPE, and IOL. Our measuring protocol showed good interobserver and intraobserver reliability. CONCLUSIONS K-wire placement toward the COT demands a smaller angle, a longer IOL, and a more distal entry point than wires placed toward AMF. These differences reflect the curved and complex anatomy of the coronoid. CLINICAL RELEVANCE This measuring algorithm can be used to plan osteosynthesis, and the obtained reference values can help understand the coronoid's complex anatomy.
Collapse
Affiliation(s)
- Philipp Egenolf
- Department of Orthopaedic and Trauma Surgery, Faculty of Medicine, University of Cologne and University Hospital Cologne, Cologne, Germany.
| | - Michael Hackl
- Department of Orthopaedic and Trauma Surgery, Faculty of Medicine, University of Cologne and University Hospital Cologne, Cologne, Germany
| | - Tim Leschinger
- Department of Orthopaedic and Trauma Surgery, Faculty of Medicine, University of Cologne and University Hospital Cologne, Cologne, Germany
| | - Andreas Harbrecht
- Department of Orthopaedic and Trauma Surgery, Faculty of Medicine, University of Cologne and University Hospital Cologne, Cologne, Germany
| | - Nadine Ott
- Department of Orthopaedic and Trauma Surgery, Faculty of Medicine, University of Cologne and University Hospital Cologne, Cologne, Germany
| | - Lars P Müller
- Department of Orthopaedic and Trauma Surgery, Faculty of Medicine, University of Cologne and University Hospital Cologne, Cologne, Germany
| | - Kilian Wegmann
- Department of Orthopaedic and Trauma Surgery, Faculty of Medicine, University of Cologne and University Hospital Cologne, Cologne, Germany
| |
Collapse
|
21
|
Leschinger T, Hackl M, Lanzerath F, Krane F, Harbrecht A, Wegmann K, Müller LP. [Elbow prosthesis after acute fractures : Indications and technique]. Unfallchirurgie (Heidelb) 2022; 125:699-708. [PMID: 35833974 DOI: 10.1007/s00113-022-01215-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 06/27/2022] [Indexed: 06/15/2023]
Abstract
Good to very good clinical results can be achieved in older patients with the implantation of a total elbow prosthesis in cases of distal humeral fractures by taking the morphological features of the fractures, the bone quality as well as the individual patient requirements and variables into account. The most commonly used design is the cemented semiconstrained linked total elbow endoprosthesis. The unlinked prosthesis design and hemiarthroplasty require intact or adequately reconstructable musculoligamentous structures or condyles and a preserved or replaced radial head. The recommended weight limit after total elbow prosthesis as well as potential intraoperative and postoperative complications must be considered and discussed with the patients. A secondary total elbow arthroplasty is also possible after primary conservative treatment approaches, e.g., in the case of contraindicated surgery in the fracture situation, persistent pain and functional restrictions. This article provides an overview of the technique and the appropriate indications.
Collapse
Affiliation(s)
- T Leschinger
- Unfall‑, Hand- und Ellenbogenchirurgie, Universitätsklinik Köln, Kerpener Straße 62, 50937, Köln, Deutschland.
| | - M Hackl
- Unfall‑, Hand- und Ellenbogenchirurgie, Universitätsklinik Köln, Kerpener Straße 62, 50937, Köln, Deutschland
| | - F Lanzerath
- Unfall‑, Hand- und Ellenbogenchirurgie, Universitätsklinik Köln, Kerpener Straße 62, 50937, Köln, Deutschland
| | - F Krane
- Unfall‑, Hand- und Ellenbogenchirurgie, Universitätsklinik Köln, Kerpener Straße 62, 50937, Köln, Deutschland
| | - A Harbrecht
- Unfall‑, Hand- und Ellenbogenchirurgie, Universitätsklinik Köln, Kerpener Straße 62, 50937, Köln, Deutschland
| | - K Wegmann
- Unfall‑, Hand- und Ellenbogenchirurgie, Universitätsklinik Köln, Kerpener Straße 62, 50937, Köln, Deutschland
- Orthopädische Chirurgie München (OCM), München, Deutschland
| | - L P Müller
- Unfall‑, Hand- und Ellenbogenchirurgie, Universitätsklinik Köln, Kerpener Straße 62, 50937, Köln, Deutschland
| |
Collapse
|
22
|
Harbrecht A, Hackl M, Leschinger T, Müller LP, Wegmann K. Focus on stability: biomechanical evaluation of external fixation technique versus locking plate osteosynthesis in 3-part proximal humeral fractures. J Shoulder Elbow Surg 2022; 31:1666-1673. [PMID: 35247574 DOI: 10.1016/j.jse.2022.01.144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 01/21/2022] [Accepted: 01/23/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND The purpose of this study was to investigate the primary stability and displacement tendencies of an external fixation system in 2 different configurations in comparison to locking plate fixation in a 3-part proximal humeral fracture model. METHODS Twenty-one fresh-frozen human cadaveric proximal humeral specimens were divided into 3 groups of 7 stripped specimens. An unstable 3-part fracture of the proximal humerus was set. Construct A consisted of the Galaxy Fixation Shoulder System, with fixation in accordance with the manufacturer's recommended technique (3 pairs of threaded wires). Construct B was fixed with an additional pair of threaded wires according to the recommendations of Gumina et al (4 pairs of threaded wires). The remaining 7 specimens were fixed with a locking plate. By use of an optical motion capture system, relative motion at the fracture site and failure load were evaluated during a cyclic loading protocol. RESULTS Plate osteosynthesis showed the highest cyclic load to failure (895 ± 239 N; range, 597-1135 N), followed by construct B (692 ± 121 N; range, 432-788 N) and construct A (350 ± 190 N; range, 139-615 N). Statistically significant differences were found between plating and construct A (P < .001), between plating and construct B (P = .031), and between construct B and construct A (P = .013). Relative motion at the fracture site, in terms of change in distance during cyclic loading, was lowest with construct B measured at the peak load of 395 N after 11 steps (1.73 ± 1.98 mm; range, 0.53-5.96 mm) and highest with construct A (8.46 ± 10.67 mm; range, 2.26-20.79 mm). Angular change measured at the peak load after 11 steps was lowest with construct B (1.19° ± 0.36°; range, 0.59°-1.7°) and highest with construct A (2.44° ± 1.63°; range, 0.77°-4.04°). Statistically significant differences were found between construct A and construct B and between construct A and plating at various steps of cyclic loading. CONCLUSION In this biomechanical study of unstable 3-part proximal humeral fractures, locking plate osteosynthesis demonstrated the highest possible load application. External fixator application with 8 threaded wires (construct B) revealed the least relative motion at the fracture site, without a statistically significant difference compared with locking plates. It therefore represents another valid technique for treatment regarding primary stability. The use of external fixator application with 6 threaded wires (construct A) resulted in the lowest stability and the highest rates of displacement.
Collapse
Affiliation(s)
- Andreas Harbrecht
- Center for Orthopedic and Trauma Surgery, Faculty of Medicine and University Hospital, University of Cologne, Cologne, Germany; Department of Anatomy I, Faculty of Medicine and University Hospital, University of Cologne, Cologne, Germany.
| | - Michael Hackl
- Center for Orthopedic and Trauma Surgery, Faculty of Medicine and University Hospital, University of Cologne, Cologne, Germany
| | - Tim Leschinger
- Center for Orthopedic and Trauma Surgery, Faculty of Medicine and University Hospital, University of Cologne, Cologne, Germany
| | - Lars P Müller
- Center for Orthopedic and Trauma Surgery, Faculty of Medicine and University Hospital, University of Cologne, Cologne, Germany
| | - Kilian Wegmann
- Center for Orthopedic and Trauma Surgery, Faculty of Medicine and University Hospital, University of Cologne, Cologne, Germany
| |
Collapse
|
23
|
Hackl M, Lanzerath F, Ries C, Harbrecht A, Leschinger T, Wegmann K, Müller LP. Trans-fracture approach for ORIF of coronal shear fractures of the distal humerus. Arch Orthop Trauma Surg 2022; 143:2519-2527. [PMID: 35731264 PMCID: PMC10110670 DOI: 10.1007/s00402-022-04501-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Accepted: 05/26/2022] [Indexed: 11/28/2022]
Abstract
INTRODUCTION Open reduction and internal fixation (ORIF) of comminuted coronal shear fractures of the distal humerus is challenging. When a concomitant lateral condyle fracture is present, it may be used for a trans-fracture approach to facilitate exposure and fracture reduction. This study aimed to investigate the frequency of lateral condyle fractures in coronal shear fractures of the distal humerus and analyze fracture reduction, fracture union and clinical results following ORIF through a trans-fracture approach. MATERIALS AND METHODS All adult patients who underwent treatment for an acute distal humerus fracture during a three-year period in our level-one trauma center were identified. All fractures were classified according to the Orthopaedic Trauma Association (OTA/AO) fracture classification system and all B3 fractures were classified according to the Dubberley classification. B3 fractures with a concomitant radial condyle fracture were identified. The clinical and radiological results, (Mayo Elbow Performance Score = MEPS, Visual Analogue Scale = VAS, range of motion), complications and revision surgeries were analyzed. RESULTS 53 patients (mean age 52 ± 19 years) were identified. 13 fractures (24.5%) were B3 fractures. Four of them (30.8%) had a concomitant radial condyle fracture. All of these patients underwent ORIF with headless cannulated compression screws and a (postero-)lateral locking plate through a trans-fracture approach. At a minimum follow-up of 24 months, the MEPS was 88 ± 12 points, the VAS was 2 ± 1 and the range of motion was 118° ± 12°. All fractures showed anatomic reduction. One patient developed partial avascular necrosis and underwent arthrolysis at 6 months. One patient underwent partial hardware removal and lateral collateral ligament bracing at 6 months. CONCLUSIONS Lateral condyle fractures are present in about one third of coronal shear fractures of the distal humerus. This injury can be used for a trans-fracture approach to facilitate exposure and to reliably achieve anatomic fracture reduction.
Collapse
Affiliation(s)
- Michael Hackl
- Faculty of Medicine, University of Cologne, Cologne, Germany. .,Center of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany.
| | - Fabian Lanzerath
- Faculty of Medicine, University of Cologne, Cologne, Germany.,Center of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Christian Ries
- Department of Orthopedics, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Andreas Harbrecht
- Faculty of Medicine, University of Cologne, Cologne, Germany.,Center of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Tim Leschinger
- Faculty of Medicine, University of Cologne, Cologne, Germany.,Center of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Kilian Wegmann
- Faculty of Medicine, University of Cologne, Cologne, Germany.,Center of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Lars Peter Müller
- Faculty of Medicine, University of Cologne, Cologne, Germany.,Center of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| |
Collapse
|
24
|
Lenz M, Kahmann S, Behbahani M, Pennig L, Hackl M, Leschinger T, Müller LP, Wegmann K. Influence of rotator cuff preload on fracture configuration in proximal humerus fractures: a proof of concept for fracture simulation. Arch Orthop Trauma Surg 2022; 143:2467-2474. [PMID: 35579703 PMCID: PMC10110707 DOI: 10.1007/s00402-022-04471-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Accepted: 04/26/2022] [Indexed: 11/29/2022]
Abstract
INTRODUCTION In regard of surgical training, the reproducible simulation of life-like proximal humerus fractures in human cadaveric specimens is desirable. The aim of the present study was to develop a technique that allows simulation of realistic proximal humerus fractures and to analyse the influence of rotator cuff preload on the generated lesions in regards of fracture configuration. MATERIALS AND METHODS Ten cadaveric specimens (6 left, 4 right) were fractured using a custom-made drop-test bench, in two groups. Five specimens were fractured without rotator cuff preload, while the other five were fractured with the tendons of the rotator cuff preloaded with 2 kg each. The humeral shaft and the shortened scapula were potted. The humerus was positioned at 90° of abduction and 10° of internal rotation to simulate a fall on the elevated arm. In two specimens of each group, the emergence of the fractures was documented with high-speed video imaging. Pre-fracture radiographs were taken to evaluate the deltoid-tuberosity index as a measure of bone density. Post-fracture X-rays and CT scans were performed to define the exact fracture configurations. Neer's classification was used to analyse the fractures. RESULTS In all ten cadaveric specimens life-like proximal humerus fractures were achieved. Two III-part and three IV-part fractures resulted in each group. The preloading of the rotator cuff muscles had no further influence on the fracture configuration. High-speed videos of the fracture simulation revealed identical fracture mechanisms for both groups. We observed a two-step fracture mechanism, with initial impaction of the head segment against the glenoid followed by fracturing of the head and the tuberosities and then with further impaction of the shaft against the acromion, which lead to separation of the tuberosities. CONCLUSION A high energetic axial impulse can reliably induce realistic proximal humerus fractures in cadaveric specimens. The preload of the rotator cuff muscles had no influence on initial fracture configuration. Therefore, fracture simulation in the proximal humerus is less elaborate. Using the presented technique, pre-fractured specimens are available for real-life surgical education. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- Maximilian Lenz
- Department for Orthopaedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Joseph-Stelzmann Strasse 24, 50931, Cologne, Germany.
| | - Stephanie Kahmann
- Department for Orthopaedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Joseph-Stelzmann Strasse 24, 50931, Cologne, Germany
| | - Mehdi Behbahani
- Department for Bioengineering, University of Applied Sciences Aachen, Heinrich-Mußmann-Straße 1, 52428, Jülich, Germany
| | - Lenhard Pennig
- Institute for Diagnostic and Interventional Radiology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Strasse 62, 50937, Cologne, Germany
| | - Michael Hackl
- Department for Orthopaedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Joseph-Stelzmann Strasse 24, 50931, Cologne, Germany
| | - Tim Leschinger
- Department for Orthopaedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Joseph-Stelzmann Strasse 24, 50931, Cologne, Germany
| | - Lars Peter Müller
- Department for Orthopaedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Joseph-Stelzmann Strasse 24, 50931, Cologne, Germany
| | - Kilian Wegmann
- Department for Orthopaedic and Trauma Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Joseph-Stelzmann Strasse 24, 50931, Cologne, Germany.,Orthopaedic Surgery Munich, OCM Clinic, Steinerstrasse 6, 81369, Munich, Germany
| |
Collapse
|
25
|
Wegmann S, Rausch V, Hackl M, Leschinger T, Scaal M, Müller LP, Wegmann K. Anatomic evaluation of the triceps tendon insertion at the proximal olecranon regarding placement of fracture fixation devices. Surg Radiol Anat 2022; 44:627-634. [PMID: 35301578 PMCID: PMC8960582 DOI: 10.1007/s00276-022-02921-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Accepted: 03/03/2022] [Indexed: 11/26/2022]
Abstract
PURPOSE Olecranon fractures, especially with a small proximal fragment, remain a surgical challenge. Soft tissue irritation and affection of the triceps muscle bear a risk of complications. In order to find an area for a soft-tissue sparing placement of implants in the treatment of olecranon fractures, we aimed to define and measure the segments of the proximal olecranon and evaluate them regarding possible plate placement. METHODS We investigated 82 elbow joints. Ethical approval was obtained from the local ethics committee, After positioning in an arm holder and a posterior approach we described the morphology of the triceps footprint, evaluated and measured the surface area of the triceps and posterior capsule and correlated the results to easily measurable anatomical landmarks. RESULTS We found a bipartite insertional footprint with a superficial tendinous triceps insertion of 218.2 mm2 (± 41.2, range 124.7-343.2), a capsular insertion of 159.3 mm2 (± 30.2, range 99.0-232.1) and a deep, muscular triceps insertion area of 138.1 mm2 (± 30.2, range 79.9-227.5). Olecranon height was 26.7 mm (± 2.3, range 20.5-32.2), and olecranon width was 25.3 mm (± 2.4, range 20.9-30.4). Average correlation between the size of the deep insertion and ulnar (r = 0.314) and radial length (r = 0.298) was obtained. CONCLUSIONS We demonstrated the bipartite morphology of the distal triceps footprint and that the deep muscular triceps insertion area by its measured size could be a possible site for the placement of fracture fixations devices. The size correlates with ulnar and radial length.
Collapse
Affiliation(s)
- Sebastian Wegmann
- Center for Orthopedic and Trauma Surgery, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany.
- Department for Orthopedic and Trauma Surgery, University Hospital Cologne, University of Cologne, Kerpener Str. 62, 50937, Köln, Germany.
| | - V Rausch
- Center for Orthopedic and Trauma Surgery, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | - M Hackl
- Center for Orthopedic and Trauma Surgery, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | - T Leschinger
- Center for Orthopedic and Trauma Surgery, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | - M Scaal
- Faculty of Medicine, Department of Anatomy II, University of Cologne, Cologne, Germany
| | - L P Müller
- Center for Orthopedic and Trauma Surgery, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| | - K Wegmann
- Center for Orthopedic and Trauma Surgery, Faculty of Medicine, University of Cologne, University Hospital Cologne, Cologne, Germany
| |
Collapse
|
26
|
Harbrecht A, Hackl M, Leschinger T, Uschok S, Müller L, Wegmann K. Metacarpal fractures - A method to simulate life-like fractures in human cadaveric specimens for surgical education. Hand Surgery and Rehabilitation 2022; 41:214-219. [DOI: 10.1016/j.hansur.2022.01.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2021] [Revised: 01/03/2022] [Accepted: 01/10/2022] [Indexed: 10/19/2022]
|
27
|
Harbrecht A, Rausch V, Wegmann K, Hackl M, Uschok S, Leschinger T, Müller LP. Fractures around the hip: inducing life-like fractures as a basis for enhanced surgical training. Arch Orthop Trauma Surg 2021; 141:1683-1690. [PMID: 33078271 DOI: 10.1007/s00402-020-03628-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Accepted: 09/30/2020] [Indexed: 01/29/2023]
Abstract
INTRODUCTION In this study we investigated if realistic fracture patterns around the hip can be produced on human cadaveric specimens with intact soft tissue envelope. Possible applications of such fractured specimens would be in surgical training. MATERIALS AND METHODS 7 cadaveric specimens (2 male, 5 female, 2 formalin-fixed, 5 fresh-frozen) were fractured. 2 specimens were fractured on both femurs, 5 only on one side, resulting in 9 fractures total. 5 fractures were set in our custom-made drop-test bench, 2 fractures by inducing axial force using a hammer, and the remaining 2 fractures by a direct dorsal approach and a chisel. AO/OTA and Pauwels classification were used to classify the fractures on the specimens by two independent trauma surgeons. RESULTS In our drop-test bench, axial load with the femur adducted by 10° resulted in an intertrochanteric fracture (AO type A1.3), adducted by 20° resulted in a femoral neck fracture (Pauwels type III). Fracture induction using a hammer resulted in two intertrochanteric fractures (AO type A2.2 right, A3.3 left). The use of a chisel resulted in both cases in a femoral neck fracture. The acetabulum could be fractured multifragmentarily through use of a hemiprosthesis as a stamp. CONCLUSION A high energetic impulse induced by a custom-made drop-test bench can successfully simulate realistic proximal femur and acetabular fractures in cadaveric specimens with intact soft tissue. Furthermore, axial load using a hammer as well as using a chisel through a direct dorsal approach represent additional methods for fracture induction. These pre-fractured specimens can be utilized in surgical education to provide a realistic teaching experience for specialized trauma education courses.
Collapse
Affiliation(s)
- Andreas Harbrecht
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
- Department of Anatomy I, Medical Faculty, University of Cologne, Cologne, Germany.
| | - Valentin Rausch
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
- Department of General and Trauma Surgery, BG University Hospital Bergmannsheil, Bürkle-de-la-Camp-Platz 1, 44789, Bochum, Germany
| | - Kilian Wegmann
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Michael Hackl
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Stephan Uschok
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Tim Leschinger
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Lars P Müller
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| |
Collapse
|
28
|
Hackl M, Buess E, Kammerlohr S, Nacov J, Staat M, Leschinger T, Müller LP, Wegmann K. A "Comma Sign"-Directed Subscapularis Repair in Anterosuperior Rotator Cuff Tears Yields Biomechanical Advantages in a Cadaveric Model. Am J Sports Med 2021; 49:3212-3217. [PMID: 34398639 DOI: 10.1177/03635465211031506] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Additional stabilization of the "comma sign" in anterosuperior rotator cuff repair has been proposed to provide biomechanical benefits regarding stability of the repair. PURPOSE This in vitro investigation aimed to investigate the influence of a comma sign-directed reconstruction technique for anterosuperior rotator cuff tears on the primary stability of the subscapularis tendon repair. STUDY DESIGN Controlled laboratory study. METHODS A total of 18 fresh-frozen cadaveric shoulders were used in this study. Anterosuperior rotator cuff tears (complete full-thickness tear of the supraspinatus and subscapularis tendons) were created, and supraspinatus repair was performed with a standard suture bridge technique. The subscapularis was repaired with either a (1) single-row or (2) comma sign technique. A high-resolution 3D camera system was used to analyze 3-mm and 5-mm gap formation at the subscapularis tendon-bone interface upon incremental cyclic loading. Moreover, the ultimate failure load of the repair was recorded. A Mann-Whitney test was used to assess significant differences between the 2 groups. RESULTS The comma sign repair withstood significantly more loading cycles than the single-row repair until 3-mm and 5-mm gap formation occurred (P≤ .047). The ultimate failure load did not reveal any significant differences when the 2 techniques were compared (P = .596). CONCLUSION The results of this study show that additional stabilization of the comma sign enhanced the primary stability of subscapularis tendon repair in anterosuperior rotator cuff tears. Although this stabilization did not seem to influence the ultimate failure load, it effectively decreased the micromotion at the tendon-bone interface during cyclic loading. CLINICAL RELEVANCE The proposed technique for stabilization of the comma sign has shown superior biomechanical properties in comparison with a single-row repair and might thus improve tendon healing. Further clinical research will be necessary to determine its influence on the functional outcome.
Collapse
Affiliation(s)
- Michael Hackl
- University of Cologne, Faculty of Medicine, Cologne, Germany.,University Hospital Cologne, Center of Orthopedic and Trauma Surgery, Cologne, Germany
| | | | - Sandra Kammerlohr
- University of Cologne, Faculty of Medicine, Cologne, Germany.,University Hospital Cologne, Center of Orthopedic and Trauma Surgery, Cologne, Germany
| | - Julia Nacov
- University of Cologne, Faculty of Medicine, Cologne, Germany.,University Hospital Cologne, Center of Orthopedic and Trauma Surgery, Cologne, Germany
| | - Manfred Staat
- Institute of Bioengineering, FH Aachen University of Applied Sciences, Jülich, Germany
| | - Tim Leschinger
- University of Cologne, Faculty of Medicine, Cologne, Germany.,University Hospital Cologne, Center of Orthopedic and Trauma Surgery, Cologne, Germany
| | - Lars P Müller
- University of Cologne, Faculty of Medicine, Cologne, Germany.,University Hospital Cologne, Center of Orthopedic and Trauma Surgery, Cologne, Germany
| | - Kilian Wegmann
- University of Cologne, Faculty of Medicine, Cologne, Germany.,University Hospital Cologne, Center of Orthopedic and Trauma Surgery, Cologne, Germany
| |
Collapse
|
29
|
Ott N, Harland A, Hackl M, Prescher A, Leschinger T, Müller LP, Wegmann K. Primary stability of fixation methods for periprosthetic fractures of the humerus: a biomechanical investigation. J Shoulder Elbow Surg 2021; 30:2184-2190. [PMID: 33581277 DOI: 10.1016/j.jse.2020.12.027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 12/19/2020] [Accepted: 12/27/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND The incidence of periprosthetic fractures of the proximal humerus is gradually increasing, following an increase in reverse shoulder arthroplasties in recent years. Locking plate fixation and revision arthroplasty are both valuable treatment methods. However, the primary stability of fixation methods for periprosthetic fractures has not been investigated in detail. The aim of this study was to analyze and compare the primary stability of the common treatment measures. MATERIALS AND METHODS Cemented reverse total shoulder arthroplasty (Delta Xtend; DePuy Synthes, Warsaw, IN, USA) was performed in 5 shoulders, and a distal, mid-diaphysis humeral fracture (Wright and Cofield type B) was induced. The implant was left in place, and 3 distinct fixation scenarios were tested: osteosynthesis using 4.5-mm locking plate fixation (subgroup A), 4.5-mm locking plate fixation with an additional 3.5-mm locking plate (subgroup B), and 4.5-mm locking plate fixation with an additional K-wire cerclage (subgroup C). The specimens were tested in a biomechanical setup simulating activities of daily living including rotation. Strain gauges (4-wire strain at 120 Ω; Vishay Measurements Group, Chartres, France) mounted on the 4.5-mm locking plates were used to evaluate the strain of the fixation and to give an estimate of primary stability. RESULTS Regarding the simulation of activities of daily living, no statistically significant differences were found in the measured strains on the locking plate between subgroups A, B, and C. A maximum measured strain of 216.85 μm/m in subgroup A resulted in bending of the locking plate (length, 134 mm) of 0.03 mm. In subgroup B (277.01 μm/m), the plate strained 0.04 mm compared with a strain measurement of 0.01 mm in subgroup C (75.93 μm/m). CONCLUSION Additional K-wire cerclages or additional 3.5-mm locked plating did not increase primary stability. With a stable prosthetic implant in place, 4.5-mm locked plating is sufficient to address periprosthetic humeral shaft fractures in the present in vitro setup.
Collapse
Affiliation(s)
- Nadine Ott
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany.
| | - Arne Harland
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Michael Hackl
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Andreas Prescher
- Institute of Molecular and Cellular Anatomy -Prosektur-, RWTH Aachen, Aachen, Germany
| | - Tim Leschinger
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Lars Peter Müller
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Kilian Wegmann
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| |
Collapse
|
30
|
Harbrecht A, Hackl M, Leschinger T, Uschok S, Wegmann K, Eysel P, Müller LP. What to expect? Injury patterns of Electric-Scooter accidents over a period of one year - A prospective monocentric study at a Level 1 Trauma Center. Eur J Orthop Surg Traumatol 2021; 32:641-647. [PMID: 34061254 PMCID: PMC8167386 DOI: 10.1007/s00590-021-03014-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Accepted: 04/28/2021] [Indexed: 11/18/2022]
Abstract
Purpose E-scooters are a new type of urban transportation utilized in Germany since June 2019, primarily in larger cities in the context of sharing offers. Such electrically operated standing scooters can be driven at a maximum speed of 20 km/h. A helmet is not mandatory. The aim of this prospective study is to document the injury patterns over the period of 1 year and compare our findings with already available data. Methods Over a period of 1 year (July 2019–July 2020), data on E-scooter-related accidents treated at a level 1 trauma center of a major German city were prospectively documented. Injury patterns were analyzed, and epidemiological data evaluated. Results Fifty-nine (35 female, 24 male) accidents were included in the observation period. Mean age of accident victims was 30.03 years (± 9.32). Alcohol influence at the time of accident was detected in 9 cases (15.25%). Many of the accident victims suffered multiple injuries. Most of the injuries were upper (50.84%) and lower extremity (47.45%) as well as craniofacial injuries (62.71%). A helmet was not worn in any of the cases. Conclusion In the year following their introduction, E-scooter-related accidents have led to an additional burden on the emergency capacities of the involved University Hospital, especially in the summer months of 2019. Protective equipment is de facto not worn. Injuries to the extremities, head, and face were most common. None of the accident victims died. This coincides with results from other major cities in national and international comparison. A more intensive education about injury consequences of unprotected E-scooter use and the discussion of a possible obligation to wear a helmet and further protection equipment for the extremities should take place.
Collapse
Affiliation(s)
- Andreas Harbrecht
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
| | - Michael Hackl
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Tim Leschinger
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Stephan Uschok
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Kilian Wegmann
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Peer Eysel
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Lars P Müller
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| |
Collapse
|
31
|
Hackl M, Nacov J, Kammerlohr S, Staat M, Buess E, Leschinger T, Müller LP, Wegmann K. Intratendinous Strain Variations of the Supraspinatus Tendon Depending on Repair Technique: A Biomechanical Analysis Regarding the Cause of Medial Cuff Failure. Am J Sports Med 2021; 49:1847-1853. [PMID: 33872064 DOI: 10.1177/03635465211006138] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Double-row (DR) and transosseous-equivalent (TOE) techniques for rotator cuff repair offer more stability and promote better tendon healing compared with single-row (SR) repairs and are preferred by many surgeons. However, they can lead to more disastrous retear patterns with failure at the medial anchor row or the musculotendinous junction. The biomechanics of medial cuff failure have not been thoroughly investigated thus far. PURPOSE To investigate the intratendinous strain distribution within the supraspinatus tendon depending on repair technique. STUDY DESIGN Controlled laboratory study. METHODS Twelve fresh-frozen cadaveric shoulders were used. The intratendinous strain within the supraspinatus tendon was analyzed in 2 regions-(1) at the footprint at the greater tuberosity and (2) medial to the footprint up to the musculotendinous junction-using a high-resolution 3-dimensional camera system. Testing was performed at submaximal loads of 40 N, 60 N, and 80 N for intact tendons, after SR repair, after DR repair, and after TOE repair. RESULTS The tendon strain of the SR group differed significantly in both regions from that of the intact tendons and the TOE group at 40 N (P≤ .043) and from the intact tendons, the DR group, and the TOE group at 60 N and 80 N (P≤ .048). SR repairs showed more tendon elongation at the footprint and less elongation medial to the footprint. DR and TOE repairs did not provide significant differences in tendon strain when compared with the intact tendons. However, the increase in tendon strain medial to the footprint from 40 N to 80 N was significantly more pronounced in the DR and TOE group (P≤ .029). CONCLUSION While DR and TOE repair techniques more closely reproduced the strains of the supraspinatus tendon than did SR repair in a cadaveric model, they showed a significantly increased tendon strain at the musculotendinous junction with higher loads in comparison with the intact tendon. CLINICAL RELEVANCE DR and TOE rotator cuff reconstructions lead to a more anatomic tendon repair. However, their use has to be carefully evaluated whenever tendon quality is diminished, as they lead to a more drastic increase in tendon strain medial to the footprint, putting these repairs at risk of medial cuff failure.
Collapse
Affiliation(s)
- Michael Hackl
- University of Cologne, Faculty of Medicine, Cologne, Germany.,University Hospital Cologne, Center of Orthopedic and Trauma Surgery, Cologne, Germany
| | - Julia Nacov
- University of Cologne, Faculty of Medicine, Cologne, Germany.,University Hospital Cologne, Center of Orthopedic and Trauma Surgery, Cologne, Germany
| | - Sandra Kammerlohr
- University of Cologne, Faculty of Medicine, Cologne, Germany.,University Hospital Cologne, Center of Orthopedic and Trauma Surgery, Cologne, Germany
| | - Manfred Staat
- Institute of Bioengineering, FH Aachen University of Applied Sciences, Jülich, Germany
| | | | - Tim Leschinger
- University of Cologne, Faculty of Medicine, Cologne, Germany.,University Hospital Cologne, Center of Orthopedic and Trauma Surgery, Cologne, Germany
| | - Lars P Müller
- University of Cologne, Faculty of Medicine, Cologne, Germany.,University Hospital Cologne, Center of Orthopedic and Trauma Surgery, Cologne, Germany
| | - Kilian Wegmann
- University of Cologne, Faculty of Medicine, Cologne, Germany.,University Hospital Cologne, Center of Orthopedic and Trauma Surgery, Cologne, Germany
| |
Collapse
|
32
|
Ott N, Harbrecht A, Hackl M, Leschinger T, Knifka J, Müller LP, Wegmann K. Inducing pilon fractures in human cadaveric specimens depending on the injury mechanism: a fracture simulation. Arch Orthop Trauma Surg 2021; 141:837-844. [PMID: 32720001 DOI: 10.1007/s00402-020-03538-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Accepted: 07/15/2020] [Indexed: 12/01/2022]
Abstract
BACKGROUND Operative management of pilon fractures, especially high-energy compression injuries, is a challenge. Operative education is of vital importance to handle these entities. Not rarely, it is cut by economics and staff shortage. As public awareness toward operative competence rises, surgical cadaver courses that provide pre-fractured specimens can improve realism of teaching scenarios. The aim of this study is to introduce a realistic pilon fracture simulation setup regarding the injury mechanism. MATERIALS AND METHODS 8 cadaveric specimens (two left, six right) were fixed onto a custom drop-test bench in dorsiflexion (20°) and light supination (10°). The proximal part of the lower leg was potted, and the specimen was exposed to a high energetic impulse via an axial impactor. CT imaging was performed after fracture simulation to detect the exact fracture patterns and to classify the achieved fractures by two independent trauma surgeons. (AO/OTA recommendations and the Rüedi/Allgöwer). RESULTS All cadaveric specimens could be successfully fractured: 6 (75%) were identified as a 43-C fracture and 2 (25%) as 43-B fracture type. Regardless of the identical mechanism two different kinds of fracture types were reported. In five cases (62.5%), the fibula was also fractured and in three specimens, a talus fracture was described. There was no statistically significant correlation found regarding Hounsfield Units (HU) and age as well as HU and required kinetic energy. CONCLUSION A high energetic axial impulse on a fixed ankle specimen in light dorsiflexion (20°) and supination (10°) induced by a custom-made drop-test bench can successfully simulate realistic pilon fractures in cadaveric specimens with intact soft tissue envelope. Although six out of eight fractures (75%) were classified as a 43-C fracture and despite putting a lot of effort into the mechanical setup, we could not achieve an absolute level of precision. Therefore, we suggest that the injury mechanism is most likely a combination of axial loading, shear and rotation. LEVEL OF EVIDENCE III.
Collapse
Affiliation(s)
- N Ott
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.
| | - A Harbrecht
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - M Hackl
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - T Leschinger
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - J Knifka
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - L P Müller
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - K Wegmann
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Kerpener Street 62, 50937, Cologne, Germany.
| |
Collapse
|
33
|
Leschinger T, Tischer T, Doepfer AK, Glanzmann M, Hackl M, Lehmann L, Müller L, Reuter S, Siebenlist S, Theermann R, Wörtler K, Banerjee M. Epicondylopathia humeri radialis. Z Orthop Unfall 2021; 160:329-340. [PMID: 33851405 DOI: 10.1055/a-1340-0931] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
BACKGROUND Lateral epicondylitis is a common orthopaedic condition often massively restricting the quality of life of the affected patients. There are a wide variety of treatment options - with varying levels of evidence. METHOD The following statements and recommendations are based on the current German S2k guideline Epicondylopathia radialis humeri (AWMF registry number: 033 - 2019). All major German specialist societies participated in this guideline, which is based on a systematic review of the literature and a structured consensus-building process. OUTCOMES Lateral epicondylitis should be diagnosed clinically and can be confirmed by imaging modalities. The Guidelines Commission issues recommendations on clinical and radiological diagnostic workup. The clinical condition results from the accumulated effect of mechanical overload, neurologic irritation and metabolic changes. Differentiating between acute and chronic disorder is helpful. Prognosis of non-surgical regimens is favourable in most cases. Most cases spontaneously resolve within 12 months. In case of unsuccessful attempted non-surgical management for at least six months, surgery may be considered as an alternative, if there is a corresponding structural morphology and clinical manifestation. At present, it is not possible to recommend a specific surgical procedure. CONCLUSION This paper provides a summary of the guideline with extracts of the recommendations and statements of its authors regarding the pathogenesis, prevention, diagnostic workup as well as non-surgical and surgical management.
Collapse
Affiliation(s)
- Tim Leschinger
- Division of Trauma, Hand and Elbow Surgery, Cologne University Medical Centre, Cologne, Germany
| | - Thomas Tischer
- Rostock University Medical Centre, Department of Orthopaedics, Rostock, Germany
| | | | | | - Michael Hackl
- Division of Trauma, Hand and Elbow Surgery, Cologne University Medical Centre, Cologne, Germany
| | - Lars Lehmann
- Department of Trauma and Hand Surgery, ViDia Christliche Kliniken Karlsruhe, St. Vincentius-Kliniken, Karlsruhe, Germany
| | - Lars Müller
- Division of Trauma, Hand and Elbow Surgery, Cologne University Medical Centre, Cologne, Germany
| | - Sven Reuter
- SRH Hochschule für Gesundheit, Campus Stuttgart, Germany
| | - Sebastian Siebenlist
- Department of Sports Orthopaedics, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Ralf Theermann
- Joint Surgery, HELIOS ENDO-Klinik Hamburg, Hamburg, Germany
| | - Klaus Wörtler
- Institute of Diagnostic and Interventional Radiology, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Marc Banerjee
- Mediapark Klinik, Cologne, Germany.,Department of Orthopaedics and Trauma Surgery, Witten/Herdecke University, Campus Cologne-Merheim, Cologne, Germany
| |
Collapse
|
34
|
Lanzerath F, Hackl M, Wegmann K, Müller LP, Leschinger T. The treatment of anteromedial coronoid facet fractures: a systematic review. J Shoulder Elbow Surg 2021; 30:942-948. [PMID: 33010433 DOI: 10.1016/j.jse.2020.09.008] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 08/31/2020] [Accepted: 09/08/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Fractures of the anteromedial facet (AMF) of the coronoid process are caused by a varus posteromedial rotational injury force, leading to instability in the ulnohumeral joint. AMF fractures are usually accompanied by avulsion of the lateral ulnar collateral ligament (LUCL). O'Driscoll's description and classification of AMF coronoid fractures has increased awareness and interest in this injury, but the optimal treatment has yet to be decided. METHODS We systematically reviewed the available literature searching electronic databases, MEDLINE using the PubMed interface and Embase. The primary objective was to determine outcome scores but also complication and revision rates depending on the fracture and its therapy in order to gain a more comprehensive picture. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines were applied. RESULTS Initially, 304 publications were identified. Finally, 10 studies were left for inclusion, all of them retrospective in design, comprising 128 patients; the majority of them were male (75.7%). A total of 114 patients (89.1%) were treated surgically and 14 patients (10.9%) were treated conservatively. Among the surgically treated patients, 70.2% were treated with LUCL refixation. The average Mayo Elbow Performance Score of the surgically treated patients was 91.5 points. The average Mayo Elbow Performance Score of the conservatively treated patients was 91.4 points. A total of 10 patients (7.8%) required reoperation. CONCLUSION Surgery of AMF fractures leads to a satisfactory functional outcome in the vast majority of patients independent of the subtype. An algorithm for LUCL fixation is still pending. Conservative treatment may be considered under strict preconditions, especially for nondisplaced subtype 1 and 2 fractures, as these fractures show satisfactory functional outcomes when treated nonoperatively.
Collapse
Affiliation(s)
- Fabian Lanzerath
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany.
| | - Michael Hackl
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Kilian Wegmann
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Lars P Müller
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Tim Leschinger
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| |
Collapse
|
35
|
Lanzerath F, Hackl M, Wegmann K, Müller LP, Leschinger T. The treatment of isolated Mason type II radial head fractures: a systematic review. J Shoulder Elbow Surg 2021; 30:487-494. [PMID: 33197586 DOI: 10.1016/j.jse.2020.10.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 10/03/2020] [Accepted: 10/07/2020] [Indexed: 02/01/2023]
Abstract
BACKGROUND Fractures of the radial head represent the most common bony injury of the elbow in adults. Radial head fractures are classified according to Mason or one of its classification modifications. Current literature does not indicate consensus on whether to treat isolated stable type II radial head fracture patterns with open reduction and internal fixation (ORIF) or nonoperatively, especially, when there is no mechanical block to motion. METHODS We systematically reviewed the available literature searching electronic databases, that is, MEDLINE using the PubMed interface and Embase, for studies published between 2011 and 2020. The primary objective was to contrast the outcome scores of these 2 different study groups and the pitfalls accompanied with the 2 different approaches. The PRISMA guidelines were applied. RESULTS The literature search left 11 studies for inclusion, all but 1 retrospective in design, comprising 319 patients. A total of 218 patients (68.3%) were treated with ORIF and 101 patients (31.7%) were treated nonoperatively. Our findings indicate that ORIF does not provide better results when compared to nonoperatively treated patients concerning functional outcome parameters. Treatment success, defined as excellent or good results according to the Mayo Elbow Performance Score or the Broberg and Morrey score, among the patients treated with ORIF was 90.9%; 7.1% were in need of subsequent surgery and 5.2% had radiologic osteoarthritic changes of the radial column. In addition, 95.1% of the nonoperative cohort were treated successfully, and osteoarthritis was present in 11.9%. Mean follow-up period of the ORIF and the nonoperative cohort was 73 and 39 months, respectively. CONCLUSION ORIF and nonoperative treatment of isolated Mason type II radial head fractures provide comparably satisfactory functional outcomes, without significant differences. Consideration of age, activity level and potential risks is recommended before making any treatment decision. Subsequent surgery rates were higher for patients treated with ORIF than for those treated nonoperatively and should be discussed. However, development of osteoarthritis of the radial column appears to be more likely after nonoperative treatment. The study pool remains limited, and implications of this review should be handled with caution.
Collapse
Affiliation(s)
- Fabian Lanzerath
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany.
| | - Michael Hackl
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Kilian Wegmann
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Lars P Müller
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| | - Tim Leschinger
- Department of Orthopedic and Trauma Surgery, University Hospital Cologne, Cologne, Germany
| |
Collapse
|
36
|
Harbrecht A, Ott N, Hackl M, Leschinger T, Wegmann K, Müller LP. [Radial head fractures : Epidemiology, diagnosis, treatment and outcome]. Unfallchirurg 2021; 124:153-162. [PMID: 33443629 DOI: 10.1007/s00113-020-00947-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Radial head fractures account for the majority of bony injuries to the elbow. The usual clinical signs include hemarthrosis, pain and limitations in movement. The standard diagnostic tool is radiological imaging using X‑rays and for more complex fractures, computed tomography (CT). Concomitant ligamentous injuries occur more frequently than expected and must be reliably excluded. The classification is based on the modified Mason classification. Mason type I fractures are usually treated conservatively with immobilization and early functional aftercare. Mason type II fractures can be well-addressed by screw osteosynthesis but higher grade fractures (Mason types III-IV) can necessitate a prosthetic radial head replacement. In this case, prosthesis implantation is to be preferred to a radial head resection. The outcome after treatment of radial head fractures can be described as good to very good if all accompanying injuries are adequately addressed.
Collapse
Affiliation(s)
- A Harbrecht
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Schwerpunkt für Unfall‑, Hand- und Ellenbogenchirurgie, Universität zu Köln, Kerpener Str. 62, 50937, Köln, Deutschland.
| | - N Ott
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Schwerpunkt für Unfall‑, Hand- und Ellenbogenchirurgie, Universität zu Köln, Kerpener Str. 62, 50937, Köln, Deutschland
| | - M Hackl
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Schwerpunkt für Unfall‑, Hand- und Ellenbogenchirurgie, Universität zu Köln, Kerpener Str. 62, 50937, Köln, Deutschland
| | - T Leschinger
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Schwerpunkt für Unfall‑, Hand- und Ellenbogenchirurgie, Universität zu Köln, Kerpener Str. 62, 50937, Köln, Deutschland
| | - K Wegmann
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Schwerpunkt für Unfall‑, Hand- und Ellenbogenchirurgie, Universität zu Köln, Kerpener Str. 62, 50937, Köln, Deutschland
| | - L P Müller
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Schwerpunkt für Unfall‑, Hand- und Ellenbogenchirurgie, Universität zu Köln, Kerpener Str. 62, 50937, Köln, Deutschland
| |
Collapse
|
37
|
Harbrecht A, Hackl M, Leschinger T, Wegmann K, Seybold D, Müller LP. Radial head fractures with interposed capitellar cartilage fragment-hindrance to bone healing-a case series. Arch Orthop Trauma Surg 2021; 141:1615-1624. [PMID: 33877448 PMCID: PMC8354868 DOI: 10.1007/s00402-021-03895-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Accepted: 04/02/2021] [Indexed: 11/17/2022]
Abstract
INTRODUCTION Radial head fractures account for the majority of bony elbow injuries. The individual treatment options have been described in detail. In some cases, however, an unusual concomitant injury occurs, which can significantly impede primary osteosynthesis and healing. This concomitant injury can be an interposing cartilaginous capitellar fragment. METHODS This retrospective study describes four cases of trapped cartilage fragments of the capitellum that compromised primary osteosynthesis or primary conservative healing of a radial head fracture. Radiological imaging, function and pain level are presented pre- and postoperatively (mean follow-up 9.25 months). RESULTS None of the four cases showed preoperative evidence of an incarcerated cartilage fragment of the capitellum. They all showed limited elbow range of motion. CT examinations were performed in all cases. In each case, the cartilage fragment was first sighted upon surgery, subsequently removed and the fractures treated with ORIF. Mean follow-up was of 9.25 months. All fractures healed, with excellent function and low pain scores. CONCLUSIONS This study presents rare cases of a trapped humeral cartilage fragment in radial head fractures. Radiological imaging including CT scans cannot reliably detect this concomitant injury. Therefore, this problem becomes apparent and treatable only during surgery. A high degree of suspicion is necessary especially in patients with minimally displaced fractures associated with limited elbow motion and a gap at the fracture site as treating these injuries conservatively may lead to poor outcome.
Collapse
Affiliation(s)
- Andreas Harbrecht
- grid.6190.e0000 0000 8580 3777Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Michael Hackl
- grid.6190.e0000 0000 8580 3777Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Tim Leschinger
- grid.6190.e0000 0000 8580 3777Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Kilian Wegmann
- grid.6190.e0000 0000 8580 3777Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| | - Dominik Seybold
- grid.412471.50000 0004 0551 2937Department of General and Trauma Surgery, BG University Hospital Bergmannsheil, Bürkle-de-la-Camp Platz 1, 44789 Bochum, Germany
| | - Lars P. Müller
- grid.6190.e0000 0000 8580 3777Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany
| |
Collapse
|
38
|
Wegmann K, Hackl M, Leschinger T, Burkhart KJ, Müller LP. Overlengthening of the radial column in radial head replacement: a review of the literature and presentation of a classification system. Arch Orthop Trauma Surg 2021; 141:1525-1539. [PMID: 33057805 PMCID: PMC8354917 DOI: 10.1007/s00402-020-03619-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2020] [Accepted: 09/30/2020] [Indexed: 11/26/2022]
Abstract
BACKGROUND Radial head arthroplasty is a common procedure in elbow surgery. It has been shown to be of benefit for the patients, but there also are relevant complications that should be prevented if possible. One significant complication is overlengthening of the radial head prosthesis. In overlengthening, the head of the prosthesis overextends the physiological level of the native radial head and leads to overcompression in the radiohumeral joint. Rapid erosion and arthritic changes may then impede the clinical outcome. The incidence of overlengthening is not precisely known, but estimations range to up to 20% of all implanted prostheses. METHODS The present review discusses the available body of literature on overlengthening and lines out a classification system that may be used to guide treatment algorithms. The classification is based on the personal experiences of the author during their clinical practice. RESULTS In low-grade overlengthening (type I) conservative treatment can be an option. In Types II-IV usually revision surgery is needed. Depending on the state of the capitulum and joint stability, it is possible re-implant a prosthesis, or rely on implant removal alone. DISCUSSION The present review aimed at shedding light into overlengthening as a complication radial head replacement and to help identify and treat it.
Collapse
Affiliation(s)
- K Wegmann
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Kerpener Street 62, 50937, Cologne, Germany.
| | - M Hackl
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | - T Leschinger
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Kerpener Street 62, 50937, Cologne, Germany
| | | | - L P Müller
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University Medical Center of Cologne, Kerpener Street 62, 50937, Cologne, Germany
| |
Collapse
|
39
|
Rausch V, Neugebauer S, Leschinger T, Müller L, Hackl M, Wegmann K. Correction: Injuries to the Coronoid Process of the Ulna with Involvement of the Lesser Sigmoid Notch. Z Orthop Unfall 2020; 160:e2. [PMID: 33124019 DOI: 10.1055/a-1295-8807] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Valentin Rausch
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Cologne, Germany
| | - Sina Neugebauer
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Cologne, Germany
| | - Tim Leschinger
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Cologne, Germany
| | - Lars Müller
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Cologne, Germany
| | - Michael Hackl
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Cologne, Germany
| | - Kilian Wegmann
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Cologne, Germany
| |
Collapse
|
40
|
Rausch V, Neugebauer S, Leschinger T, Müller L, Wegmann K, Hackl M. Injuries to the Coronoid Process of the Ulna with Involvement of the Lesser Sigmoid Notch. Z Orthop Unfall 2020; 160:35-39. [PMID: 33063301 DOI: 10.1055/a-1263-1742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
INTRODUCTION This study aimed to describe the involvement of the lesser sigmoid notch in fractures to the coronoid process. We hypothesized that injuries to the lateral aspect of the coronoid process regularly involve the annular ligament insertion at the anterior lesser sigmoid notch. MATERIAL AND METHODS Patients treated for a coronoid process fracture at our institution between 06/2011 and 07/2018 were included. We excluded patients < 18 years, patients with arthritic changes or previous operative treatment to the elbow, and patients with concomitant injuries to the proximal ulna. In patients with involvement of the lesser sigmoid notch, the coronoid height and fragment size (anteroposterior, mediolateral, and craniocaudal) were measured. RESULTS Seventy-two patients (mean age: 47 years ± 17.6) could be included in the study. Twenty-one patients (29.2%) had a fracture involving the lateral sigmoid notch. The mean anteroposterior fragment length was 7 ± 1.6 mm. The fragment affected a mean of 43 ± 10.8% of the coronoid height. The mean mediolateral size of the fragment was 10 ± 5.0 mm, and the mean cranio-caudal size was 7 ± 2.7 mm. CONCLUSION Coronoid fractures regularly include the lesser sigmoid notch. These injuries possibly affect the anterior annular ligament insertion which is important for the stability of the proximal radioulnar joint and varus stability of the elbow.
Collapse
Affiliation(s)
- Valentin Rausch
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Cologne, Germany
| | - Sina Neugebauer
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Cologne, Germany
| | - Tim Leschinger
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Cologne, Germany
| | - Lars Müller
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Cologne, Germany
| | - Kilian Wegmann
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Cologne, Germany
| | - Michael Hackl
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Cologne, Germany
| |
Collapse
|
41
|
Rausch V, Krieter JP, Leschinger T, Hackl M, Scaal M, Müller LP, Wegmann K. The Radioulnar Distance at the Level of the Radial Tuberosity. Clin Anat 2019; 33:661-666. [PMID: 31576589 DOI: 10.1002/ca.23483] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2019] [Revised: 09/05/2019] [Accepted: 09/15/2019] [Indexed: 11/08/2022]
Abstract
Ruptures of the distal biceps brachii tendon are generally treated operatively due to their loss of supination and flexion force. A mechanical impingement at the insertion of the tendon at the radial tuberosity is discussed to play a role in the etiology of this injury. The aim of this study was to present a detailed, three-dimensional anatomical analysis of the radioulnar space at the radial tuberosity. A total of 166 imprints of the radioulnar space in neutral rotation and pronation from 84 cadaveric specimens of both arms using silicone impression material were produced for this study. Imprints were cut in slices of 3 mm and digitally measured after picture acquisition using a high-resolution digital camera. Distances were grouped into a proximal, central, and distal groups and used for correlation to morphometric data at the elbow (radial head diameter, ulna and radius length) as well as volume calculation. The mean radioulnar distance was 8.8 ± 4.0 mm in neutral rotation and 7.8 ± 3.9 mm in pronation. In pronation, the central zone was the smallest whereas in neutral rotation the proximal zone was the smallest. The volume of the radioulnar space did not reduce significantly during pronation. Little space is provided for the insertion of the distal biceps brachii tendon especially during pronation. This could play a role in the etiology of distal biceps brachii tendon ruptures and should be considered in the fixation after rupture of the tendon. Clin. Anat., 33:661-666, 2020. © 2019 Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Valentin Rausch
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Jan P Krieter
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Tim Leschinger
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Michael Hackl
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Martin Scaal
- Department of Anatomy II, University of Cologne, Cologne, Germany
| | - Lars P Müller
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| | - Kilian Wegmann
- Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, University of Cologne, Kerpener Str. 62, 50937, Cologne, Germany
| |
Collapse
|
42
|
Wegmann K, Rausch V, Burkhart KJ, Hackl M, Leschinger T, Müller L. Advanced Surgical Trauma Care Course - Evaluation of a Fracture Simulation Course Concept with Intact Soft Tissue. Z Orthop Unfall 2019; 158:291-297. [PMID: 31533163 DOI: 10.1055/a-0983-8322] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
PURPOSE Currently, surgical training in the clinical scenario is limited by duty-hour restrictions as well as an increasing specialization within the numerous surgical fields. In such an environment, surgical training in subspecialties becomes both, more important and challenging. Against this background, purpose of the present study was to evaluate a new course format for advanced training in fracture treatment. In the studied course format, cadaveric wrist or elbow specimens with prefabricated fractures were used with the aim of improving the learning effect for the attendees. On these specimens, operative treatment with specific osteosynthetic implants was performed under radiographic control. We hypothesized that simulation in a complex scenario such as the one used in the studied course format leads to a subjectively better learning effect regardless of prior surgical experience. METHODS 205 participants in 16 courses between 2016 and 2018 were surveyed regarding their operative experience, previously attendances of trauma care trainings and subjective learning effect in the surveyed course and the trainings attended previously. Based on a ten-step scale, results in the subjective learning effect were compared between the investigated course and other trainings and to the individual operative experience. RESULTS The learning effect of the surveyed fracture courses was assessed with a median of 9/10 for the theoretical part and 10/10 for the practical part, significantly better than in trainings attended previously. The surveyed participants reported that they each performed 308 operations per year on average. Other course formats were attended significantly more frequent than courses on prefractured human specimens. The respondents reported a subjectively higher learning effect of the evaluated course concept in comparison to previously attended courses in practical and theoretical aspects. CONCLUSIONS The reported innovative course format is an efficient concept for education in surgical trauma care, suited for more novice and advanced surgeons.
Collapse
Affiliation(s)
- Kilian Wegmann
- University of Cologne, Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, Germany
| | - Valentin Rausch
- University of Cologne, Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, Germany
| | | | - Michael Hackl
- University of Cologne, Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, Germany
| | - Tim Leschinger
- University of Cologne, Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, Germany
| | - Lars Müller
- University of Cologne, Faculty of Medicine and University Hospital, Center for Orthopedic and Trauma Surgery, Germany
| |
Collapse
|
43
|
Leschinger T, Besch K, Aydin C, Staat M, Scaal M, Müller LP, Wegmann K. Irreparable Rotator Cuff Tears: A Biomechanical Comparison of Superior Capsuloligamentous Complex Reconstruction Techniques and an Interpositional Graft Technique. Orthop J Sports Med 2019; 7:2325967119864590. [PMID: 31489328 PMCID: PMC6709439 DOI: 10.1177/2325967119864590] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/05/2022] Open
Abstract
Background: Irreparable rotator cuff tears lead to superior translation of the humeral
head. Numerous surgical management options are available to treat the
condition. Purpose: To compare superior capsule stability among different types of patch grafting
in irreparable rotator cuff tears. Methods: Six cadaveric shoulders were tested in a custom-designed shoulder testing
system. Superior translation of the humerus and subacromial contact pressure
were quantified in an intact condition (condition 1), after cutting the
supraspinatus tendon (condition 2), and after additionally cutting the
superior capsuloligamentous complex (condition 3). The results were compared
among 3 types of patch grafting, in which capsule reconstruction was
achieved by glenoidal 3-point (condition 4) or 2-point (condition 5)
fixation or by affixing a graft below the acromion (condition 6). Results: No significant difference in subacromial pressure was measured by
reconstruction with 2 or 3 anchors compared with conditions 1 and 2
(P > .05). However, with 3-point fixation, lower
levels of pressure were measured than with 2-point fixation. Moreover,
superior translation values were lower with 3-point fixation; the same
applied for values of the preserved capsule as compared with the torn
capsule. In condition 6, a significant increase in pressure in the neutral
position was documented (P < .05). Conclusion: The superior capsuloligamentous complex plays an important role in
stabilizing the glenohumeral joint. The results suggest that with additional
medial anchoring at the coracoid base, the depressing and centering effect
of the superior complex can probably be regained in a more physiological way
compared with a reconstructed capsule with 2 glenoid attachments or with an
interpositional graft below the acromion.
Collapse
Affiliation(s)
- Tim Leschinger
- Center for Orthopedic and Trauma Surgery, University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Katharina Besch
- Center for Orthopedic and Trauma Surgery, University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Cansu Aydin
- Biomechanics Laboratory, Institute of Bioengineering, Aachen University of Applied Sciences, Aachen, Germany
| | - Manfred Staat
- Biomechanics Laboratory, Institute of Bioengineering, Aachen University of Applied Sciences, Aachen, Germany
| | - Martin Scaal
- Institute of Anatomy II, University of Cologne, Cologne, Germany
| | - Lars Peter Müller
- Center for Orthopedic and Trauma Surgery, University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Kilian Wegmann
- Center for Orthopedic and Trauma Surgery, University Hospital Cologne, University of Cologne, Cologne, Germany
| |
Collapse
|
44
|
Rausch V, Hackl M, Oppermann J, Leschinger T, Scaal M, Müller LP, Wegmann K. Peroneal nerve location at the fibular head: an anatomic study using 3D imaging. Arch Orthop Trauma Surg 2019; 139:921-926. [PMID: 30737594 DOI: 10.1007/s00402-019-03141-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2018] [Indexed: 02/07/2023]
Abstract
INTRODUCTION Injuries to the peroneal nerve are a common complication in operative treatment of proximal tibial or fibular fractures. To minimize the risk of iatrogenic injury to the nerve, detailed knowledge of the anatomy of the peroneal nerve is essential. Aim of this study was to present a detailed description of the position and branching of the peroneal nerve based on 3D-images to assist preparation for surgical approaches to the fibular head and the tibial plateau. METHODS The common peroneal nerve, the deep and the superficial peroneal nerve were marked with a radiopaque thread in 18 formalin-embalmed specimens. Three-dimensional X-ray scans were then acquired from the knee and the proximal lower leg in full extension of the knee. In 3D-reconstructions of these scans, distances of the common peroneal nerve and its branches to clearly defined osseous landmarks were measured digitally. Furthermore, the height of the branching of the common peroneal nerve was measured in relation to the landmarks. RESULTS The mean distance of the common peroneal nerve at the level of the tibial plateau to its posterior osseous limitation was 7.92 ± 2.42 mm, and 1.31 ± 2.63 mm to the lateral osseous limitation of the tibia. In a transversal plane, distance of the common peroneal nerve branching was 27.56 ± 3.98 mm relative to the level of the most proximal osseous extension of fibula and 11.77 ± 6.1 mm relative to the proximal extension of the tibial tuberosity. The deep peroneal nerve crossed the midline of the fibular shaft at a distance of 22.14 mm ± 4.35 distally to the most proximal extension of the fibula, the superficial peroneal nerve at a distance of 33.56 mm ± 6.68. CONCLUSION As the course of the peroneal nerve is highly variable in between individuals, surgical dissection for operative treatment of proximal posterolateral tibial or fibular fractures has to be done carefully. We defined an area were the peroneal nerve and its branches are unlikely to be found. However, specific safe zones should not be utilized due to the individual anatomic variation.
Collapse
Affiliation(s)
- V Rausch
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Kerpener Str. 62, 50937, Cologne, Germany.
| | - M Hackl
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Kerpener Str. 62, 50937, Cologne, Germany
| | - J Oppermann
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Kerpener Str. 62, 50937, Cologne, Germany
| | - T Leschinger
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Kerpener Str. 62, 50937, Cologne, Germany
| | - M Scaal
- Department of Anatomy II, Medical Faculty, University of Cologne, Cologne, Germany
| | - L P Müller
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Kerpener Str. 62, 50937, Cologne, Germany
| | - K Wegmann
- Center for Orthopedic and Trauma Surgery, University of Cologne, Faculty of Medicine and University Hospital, Kerpener Str. 62, 50937, Cologne, Germany
| |
Collapse
|
45
|
Hackl M, Leschinger T, Rausch V, Wegmann K, Müller LP. Therapieoptionen bei schmerzhaften Folgezuständen nach Radiuskopffraktur. Arthroskopie 2019. [DOI: 10.1007/s00142-019-0289-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
46
|
Leschinger T, Birgel S, Hackl M, Staat M, Müller LP, Wegmann K. A musculoskeletal shoulder simulation of moment arms and joint reaction forces after medialization of the supraspinatus footprint in rotator cuff repair. Comput Methods Biomech Biomed Engin 2019; 22:595-604. [DOI: 10.1080/10255842.2019.1572749] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Affiliation(s)
- Tim Leschinger
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany
- Institute of Bioengineering, Biomechanics Lab., Aachen University of Applied Sciences, Jülich, Germany
| | - Stefan Birgel
- Institute of Bioengineering, Biomechanics Lab., Aachen University of Applied Sciences, Jülich, Germany
| | - Michael Hackl
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany
| | - Manfred Staat
- Institute of Bioengineering, Biomechanics Lab., Aachen University of Applied Sciences, Jülich, Germany
| | - Lars Peter Müller
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany
| | - Kilian Wegmann
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany
| |
Collapse
|
47
|
Rausch V, Wegmann S, Hackl M, Leschinger T, Neiss WF, Scaal M, Müller LP, Wegmann K. Insertional anatomy of the anterior medial collateral ligament on the sublime tubercle of the elbow. J Shoulder Elbow Surg 2019; 28:555-560. [PMID: 30391185 DOI: 10.1016/j.jse.2018.08.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/17/2018] [Revised: 07/31/2018] [Accepted: 08/05/2018] [Indexed: 02/01/2023]
Abstract
BACKGROUND Acute injuries to the anterior medial collateral ligament (AMCL) can occur due to valgus trauma or during other dislocating events to the elbow. AMCL lesions are often associated with bony lesions, such as radial head fractures or fractures of the coronoid process. We analyzed the insertion of the AMCL on the sublime tubercle in relation to surrounding osseous structures. We aimed to increase the understanding of the involvement of the AMCL in bony lesions to the sublime tubercle. METHODS We investigated 86 elbows from 43 embalmed human specimens. We measured the most ventral extensions of the AMCL at the sublime tubercle in relation to a clearly defined and reproducible landmark. We used as our landmark a horizontal line (baseline) originating on the lesser sigmoid notch in a right angle to the ulnar ridge. RESULTS The mean distance of the coronoid process tip to the baseline was 4.0 mm (standard deviation [SD], 1.3 mm; range, 1.4-6.7 mm). The mean distance of the ventral extension of the AMCL to the horizontal line was 3.7 mm (SD, 2.6 mm; range: 9.4-2.2 mm). The mean horizontal distance between the ventral aspect of the AMCL and the coronoid tip was 13.7 mm (SD, 2.5 mm; range, 7.7-20.5 mm). CONCLUSIONS We present a detailed description of the insertional anatomy of the AMCL at the sublime tubercle. These values could be helpful for classifications of coronoid fractures and to estimate the involvement of the AMCL in fractures of the sublime tubercle.
Collapse
Affiliation(s)
- Valentin Rausch
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany; Department of Anatomy I, Medical Faculty, University of Cologne, Cologne, Germany.
| | - Sebastian Wegmann
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany
| | - Michael Hackl
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany
| | - Tim Leschinger
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany
| | - Wolfram F Neiss
- Department of Anatomy I, Medical Faculty, University of Cologne, Cologne, Germany
| | - Martin Scaal
- Department of Anatomy II, Medical Faculty, University of Cologne, Cologne, Germany
| | - Lars P Müller
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany
| | - Kilian Wegmann
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany
| |
Collapse
|
48
|
Leschinger T, Krane F, Hackl M, van Tongel A, Scaal M, Müller LP, Wegmann K. The dominant nutrient foramen at the clavicular midshaft: an anatomical study. Surg Radiol Anat 2018; 41:361-364. [DOI: 10.1007/s00276-018-2169-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2018] [Accepted: 12/08/2018] [Indexed: 10/27/2022]
|
49
|
Abstract
When the elbow is destroyed due to rheumatic diseases, the joint can be replaced by a prosthesis and total arthroplasty. Improved pharmaceutical treatment for rheumatic diseases has, however, reduced the number of implantations in these patients. Reported 10-year survival rates of the implant currently achieve 81-90%.; however, due to limited long-term survival of the implant and high complication rates, total elbow arthroplasty should still be used with caution. Continuous technical improvements in the available prostheses and in surgical techniques could lead in the future to a decline in complications, such as aseptic loosening and infections.
Collapse
Affiliation(s)
- V Rausch
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Schwerpunkt für Unfall‑, Hand- und Ellenbogenchirurgie, Uniklinik Köln, Kerpener Str. 62, 50937, Köln, Deutschland.
| | - M Hackl
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Schwerpunkt für Unfall‑, Hand- und Ellenbogenchirurgie, Uniklinik Köln, Kerpener Str. 62, 50937, Köln, Deutschland
| | - T Leschinger
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Schwerpunkt für Unfall‑, Hand- und Ellenbogenchirurgie, Uniklinik Köln, Kerpener Str. 62, 50937, Köln, Deutschland
| | - L P Müller
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Schwerpunkt für Unfall‑, Hand- und Ellenbogenchirurgie, Uniklinik Köln, Kerpener Str. 62, 50937, Köln, Deutschland
| | - K Wegmann
- Klinik und Poliklinik für Orthopädie und Unfallchirurgie, Schwerpunkt für Unfall‑, Hand- und Ellenbogenchirurgie, Uniklinik Köln, Kerpener Str. 62, 50937, Köln, Deutschland
| |
Collapse
|
50
|
Leschinger T, Engel K, Brüggemann GP, Dederer V, Neiss WF, Scheyerer MJ, Müller LP, Wegmann K. Glass -polyalkenoate cement: An alternative material for kyphoplasty in osteoporotic vertebral compression fractures - An ex vivo study. J Mech Behav Biomed Mater 2018; 83:46-51. [PMID: 29677554 DOI: 10.1016/j.jmbbm.2018.03.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2017] [Revised: 02/27/2018] [Accepted: 03/05/2018] [Indexed: 12/27/2022]
Abstract
Adjacent vertebral body fracture is described as a risk after vertebroplasty and kyphoplasty. It may be true that this phenomenon is caused precisely because of the frequently used polymethylmethacrylate cement (PMMA), which shows a higher level of stiffness than bone material and may ultimately lead to shifting stress levels within the entire spine. The goal of the present study was to evaluate and compare the pressure distribution in the endplate of human vertebrae after kyphoplasty with PMMA and aluminum-free glass-polyalkenoate cement (gpc). For the present study, 8 fresh frozen human cadaveric vertebral bodies from the thoracolumbar junction were used. All vertebrae were augmented transpedicularly on one side with gpc and on the other side with PMMA. A loading of 600 N, 800 N and 1000 N was applied. In the data processing an individual region of interest (roi) was generated for each vertebra. The following parameters were determined for each roi: maximum force [N], maximum pressure [kPa], mean pressure [kPa], roi area [cm2]. We found significantly higher mean pressure values in the areas of the vertebrae augmented with PMMA, compared to the ones after augmentation with gpc (p = 0.012) when applying 1000 N. In the groups with lower forces there were no statistical relevant differences. The pressure distribution shows an advantage for gpc. A material, which does not create load concentration onto the cranial and caudal vertebral surface, could have major advantages concerning the risk of adjacent vertebral fractures. Thus the results of the 1000 N loading protocol suggest gpc being a possible alternative to ordinary PMMA cement, regarding its influence on stiffness in kyphoplasty. These and other general aspects like incorporation should be addressed and elaborated more detailed in further studies.
Collapse
Affiliation(s)
- Tim Leschinger
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany; Cologne Center for Musculoskeletal Biomechanics, Medical Faculty, University of Cologne, Cologne, Germany.
| | - Karsten Engel
- Institute of Biomechanics and Orthopaedics, German Sport University Cologne, Cologne, Germany
| | - Gert Peter Brüggemann
- Cologne Center for Musculoskeletal Biomechanics, Medical Faculty, University of Cologne, Cologne, Germany; Institute of Biomechanics and Orthopaedics, German Sport University Cologne, Cologne, Germany
| | - Viktoria Dederer
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany; Cologne Center for Musculoskeletal Biomechanics, Medical Faculty, University of Cologne, Cologne, Germany
| | | | - Max Joseph Scheyerer
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany; Cologne Center for Musculoskeletal Biomechanics, Medical Faculty, University of Cologne, Cologne, Germany
| | - Lars Peter Müller
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany; Cologne Center for Musculoskeletal Biomechanics, Medical Faculty, University of Cologne, Cologne, Germany
| | - Kilian Wegmann
- Center for Orthopedic and Trauma Surgery, University Medical Center, Cologne, Germany; Cologne Center for Musculoskeletal Biomechanics, Medical Faculty, University of Cologne, Cologne, Germany
| |
Collapse
|