1
|
Odstrcil T, Laggner FM, Rosenthal AM, Bortolon A, Hughes JW, Spendlove JC, Wilks TM. Robust identification of multiple-input single-output system response for efficient pickup noise removal from tokamak diagnostics. Rev Sci Instrum 2022; 93:103503. [PMID: 36319373 DOI: 10.1063/5.0100988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2022] [Accepted: 08/04/2022] [Indexed: 06/16/2023]
Abstract
Electromagnetic pickup noise in the tokamak environment imposes an imminent challenge for measuring weak diagnostic photocurrents in the nA range. The diagnostic signal can be contaminated by an unknown mixture of crosstalk signals from coils powered by currents in the kA range. To address this issue, an algorithm for robust identification of linear multi-input single-output (MISO) systems has been developed. The MISO model describes the dynamic relationship between measured signals from power sources and observed signals in the diagnostic and allows for a precise subtraction of the noise component. The proposed method was tested on experimental diagnostic data from the DIII-D tokamak, and it has reduced noise by up to 20 dB in the 1-20 kHz range.
Collapse
Affiliation(s)
- T Odstrcil
- General Atomics, San Diego, California 92186-5608, USA
| | - F M Laggner
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - A M Rosenthal
- MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
| | - A Bortolon
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - J W Hughes
- MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
| | | | - T M Wilks
- MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
| |
Collapse
|
2
|
Rosenthal AM, Hughes JW, Bortolon A, Laggner FM, Wilks TM, Vieira R, Leccacorvi R, Marmar E, Nagy A, Freeman C, Mauzey D. A 1D Lyman-alpha profile camera for plasma edge neutral studies on the DIII-D tokamak. Rev Sci Instrum 2021; 92:033523. [PMID: 33820041 DOI: 10.1063/5.0024115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Accepted: 02/11/2021] [Indexed: 06/12/2023]
Abstract
A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-α) emission from hydrogen isotopes, which can be used to infer neutral density and ionization rate profiles. The system is composed of two cameras, each providing a toroidal fan of 20 lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras' views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of ∼2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-α reflective mirror, narrow-band Ly-α transmission filter, and a 20 channel AXUV photodetector. The combined mirror and transmission filter have a FWHM of 5 nm, centered near the Ly-α wavelength of 121.6 nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-α brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling, and radial particle transport.
Collapse
Affiliation(s)
- A M Rosenthal
- MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
| | - J W Hughes
- MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
| | - A Bortolon
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - F M Laggner
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - T M Wilks
- MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
| | - R Vieira
- MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
| | - R Leccacorvi
- MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
| | - E Marmar
- MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
| | - A Nagy
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - C Freeman
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - D Mauzey
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| |
Collapse
|
3
|
Laggner FM, Bortolon A, Rosenthal AM, Wilks TM, Hughes JW, Freeman C, Golfinopoulos T, Nagy A, Mauzey D, Shafer MW. Absolute calibration of the Lyman-α measurement apparatus at DIII-D. Rev Sci Instrum 2021; 92:033522. [PMID: 33820112 DOI: 10.1063/5.0038134] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Accepted: 01/13/2021] [Indexed: 06/12/2023]
Abstract
The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.
Collapse
Affiliation(s)
- F M Laggner
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - A Bortolon
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - A M Rosenthal
- MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
| | - T M Wilks
- MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
| | - J W Hughes
- MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
| | - C Freeman
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - T Golfinopoulos
- MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139, USA
| | - A Nagy
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - D Mauzey
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543, USA
| | - M W Shafer
- Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831, USA
| |
Collapse
|
4
|
Lionel AC, Tammimies K, Vaags AK, Rosenfeld JA, Ahn JW, Merico D, Noor A, Runke CK, Pillalamarri VK, Carter MT, Gazzellone MJ, Thiruvahindrapuram B, Fagerberg C, Laulund LW, Pellecchia G, Lamoureux S, Deshpande C, Clayton-Smith J, White AC, Leather S, Trounce J, Melanie Bedford H, Hatchwell E, Eis PS, Yuen RKC, Walker S, Uddin M, Geraghty MT, Nikkel SM, Tomiak EM, Fernandez BA, Soreni N, Crosbie J, Arnold PD, Schachar RJ, Roberts W, Paterson AD, So J, Szatmari P, Chrysler C, Woodbury-Smith M, Brian Lowry R, Zwaigenbaum L, Mandyam D, Wei J, Macdonald JR, Howe JL, Nalpathamkalam T, Wang Z, Tolson D, Cobb DS, Wilks TM, Sorensen MJ, Bader PI, An Y, Wu BL, Musumeci SA, Romano C, Postorivo D, Nardone AM, Monica MD, Scarano G, Zoccante L, Novara F, Zuffardi O, Ciccone R, Antona V, Carella M, Zelante L, Cavalli P, Poggiani C, Cavallari U, Argiropoulos B, Chernos J, Brasch-Andersen C, Speevak M, Fichera M, Ogilvie CM, Shen Y, Hodge JC, Talkowski ME, Stavropoulos DJ, Marshall CR, Scherer SW. Disruption of the ASTN2/TRIM32 locus at 9q33.1 is a risk factor in males for autism spectrum disorders, ADHD and other neurodevelopmental phenotypes. Hum Mol Genet 2013; 23:2752-68. [PMID: 24381304 DOI: 10.1093/hmg/ddt669] [Citation(s) in RCA: 112] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
Rare copy number variants (CNVs) disrupting ASTN2 or both ASTN2 and TRIM32 have been reported at 9q33.1 by genome-wide studies in a few individuals with neurodevelopmental disorders (NDDs). The vertebrate-specific astrotactins, ASTN2 and its paralog ASTN1, have key roles in glial-guided neuronal migration during brain development. To determine the prevalence of astrotactin mutations and delineate their associated phenotypic spectrum, we screened ASTN2/TRIM32 and ASTN1 (1q25.2) for exonic CNVs in clinical microarray data from 89 985 individuals across 10 sites, including 64 114 NDD subjects. In this clinical dataset, we identified 46 deletions and 12 duplications affecting ASTN2. Deletions of ASTN1 were much rarer. Deletions near the 3' terminus of ASTN2, which would disrupt all transcript isoforms (a subset of these deletions also included TRIM32), were significantly enriched in the NDD subjects (P = 0.002) compared with 44 085 population-based controls. Frequent phenotypes observed in individuals with such deletions include autism spectrum disorder (ASD), attention deficit hyperactivity disorder (ADHD), speech delay, anxiety and obsessive compulsive disorder (OCD). The 3'-terminal ASTN2 deletions were significantly enriched compared with controls in males with NDDs, but not in females. Upon quantifying ASTN2 human brain RNA, we observed shorter isoforms expressed from an alternative transcription start site of recent evolutionary origin near the 3' end. Spatiotemporal expression profiling in the human brain revealed consistently high ASTN1 expression while ASTN2 expression peaked in the early embryonic neocortex and postnatal cerebellar cortex. Our findings shed new light on the role of the astrotactins in psychopathology and their interplay in human neurodevelopment.
Collapse
|
5
|
Ellison JW, Ravnan JB, Rosenfeld JA, Morton SA, Neill NJ, Williams MS, Lewis J, Torchia BS, Walker C, Traylor RN, Moles K, Miller E, Lantz J, Valentin C, Minier SL, Leiser K, Powell BR, Wilks TM, Shaffer LG. Clinical utility of chromosomal microarray analysis. Pediatrics 2012; 130:e1085-95. [PMID: 23071206 DOI: 10.1542/peds.2012-0568] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
OBJECTIVE To test the hypothesis that chromosomal microarray analysis frequently diagnoses conditions that require specific medical follow-up and that referring physicians respond appropriately to abnormal test results. METHODS A total of 46,298 postnatal patients were tested by chromosomal microarray analysis for a variety of indications, most commonly intellectual disability/developmental delay, congenital anomalies, dysmorphic features, and neurobehavioral problems. The frequency of detection of abnormalities associated with actionable clinical features was tallied, and the rate of physician response to a subset of abnormal tests results was monitored. RESULTS A total of 2088 diagnoses were made of more than 100 different disorders that have specific clinical features that warrant follow-up. The detection rate for these conditions using high-resolution whole-genome microarrays was 5.4%, which translates to 35% of all clinically significant abnormal test results identified in our laboratory. In a subset of cases monitored for physician response, appropriate clinical action was taken more than 90% of the time as a direct result of the microarray finding. CONCLUSIONS The disorders diagnosed by chromosomal microarray analysis frequently have clinical features that need medical attention, and physicians respond to the diagnoses with specific clinical actions, thus arguing that microarray testing provides clinical utility for a significant number of patients tested.
Collapse
Affiliation(s)
- Jay W Ellison
- Signature Genomic Laboratories, PerkinElmer, Inc, Spokane, Washington 99207, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|