Panelli A, Grimm AM, Krause S, Verfuß MA, Ulm B, Grunow JJ, Bartels HG, Carbon NM, Niederhauser T, Weber-Carstens S, Brochard L, Schaller SJ. Noninvasive Electromagnetic Phrenic Nerve Stimulation in Critically Ill Patients: A Feasibility Study. Chest 2024:S0012-3692(24)00271-X. [PMID: 38403186 DOI: 10.1016/j.chest.2024.02.035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 02/20/2024] [Accepted: 02/20/2024] [Indexed: 02/27/2024] Open
Abstract
BACKGROUND Electromagnetic stimulation of the phrenic nerve induces diaphragm contractions, but no coils for clinical use have been available. We recently demonstrated the feasibility of ventilation using bilateral transcutaneous noninvasive electromagnetic phrenic nerve stimulation (NEPNS) before surgery in lung-healthy, normal-weight patients in a dose-dependent manner. RESEARCH QUESTION Is NEPNS feasible in critically ill patients in an ICU setting? STUDY DESIGN AND METHODS This feasibility nonrandomized controlled study aimed to enroll patients within 36 h of intubation who were expected to remain ventilated for ≥ 72 h. The intervention group received 15-min bilateral transcutaneous NEPNS bid, whereas the control group received standard care. If sufficient, NEPNS was used without pressure support to ventilate the patient; pressure support was added if necessary to ventilate the patient adequately. The primary outcome was feasibility, measured as time to find the optimal stimulation position. Further end points were sessions performed according to the protocol or allowing a next-day catch-up session and tidal volume achieved with stimulation reaching only 3 to 6 mL/kg ideal body weight (IBW). A secondary end point was expiratory diaphragm thickness measured with ultrasound from days 1 to 10 (or extubation). RESULTS The revised European Union regulation mandated reapproval of medical devices, prematurely halting the study. Eleven patients (five in the intervention group, six in the control group) were enrolled. The median time to find an adequate stimulation position was 23 s (interquartile range, 12-62 s). The intervention bid was executed in 87% of patients, and 92% of patients including a next-day catch-up session. Ventilation with 3 to 6 mL/kg IBW was achieved in 732 of 1,701 stimulations (43.0%) with stimulation only and in 2,511 of 4,036 stimulations (62.2%) with additional pressure support. A decrease in diaphragm thickness was prevented by bilateral NEPNS (P = .034) until day 10. INTERPRETATION Bilateral transcutaneous NEPNS was feasible in the ICU setting with the potential benefit of preventing diaphragm atrophy during mechanical ventilation. NEPNS ventilation effectiveness needs further assessment. TRIAL REGISTRY ClinicalTrials.gov; No.: NCT05238753; URL: www. CLINICALTRIALS gov.
Collapse
Affiliation(s)
- Alessandro Panelli
- Department of Anesthesiology and Intensive Care Medicine (CVK, CCM), Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Aline M Grimm
- Department of Anesthesiology and Intensive Care Medicine (CVK, CCM), Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Sven Krause
- Institute for Human Centered Engineering, Bern University of Applied Sciences, Biel/Bienne, Switzerland
| | - Michael A Verfuß
- Department of Anesthesiology and Intensive Care Medicine (CVK, CCM), Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Bernhard Ulm
- Klinikum rechts der Isar, Department of Anesthesiology and Intensive Care, School of Medicine, Technical University of Munich, Munich, Germany; Department of Anaesthesiology and Intensive Care Medicine, School of Medicine, University of Ulm, Ulm, Germany
| | - Julius J Grunow
- Department of Anesthesiology and Intensive Care Medicine (CVK, CCM), Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Hermann G Bartels
- Department of Anesthesiology and Intensive Care Medicine (CVK, CCM), Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Niklas M Carbon
- Department of Anesthesiology and Intensive Care Medicine (CVK, CCM), Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany; Department of Anesthesiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Uniklinikum Erlangen, Erlangen, Germany
| | - Thomas Niederhauser
- Institute for Human Centered Engineering, Bern University of Applied Sciences, Biel/Bienne, Switzerland
| | - Steffen Weber-Carstens
- Department of Anesthesiology and Intensive Care Medicine (CVK, CCM), Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
| | - Laurent Brochard
- Keenan Research Centre for Biomedical Science, Li Ka Shing Knowledge Institute, Unity Health Toronto, Toronto, ON, Canada; Interdepartmental Division of Critical Care, University of Toronto, Toronto, ON, Canada
| | - Stefan J Schaller
- Department of Anesthesiology and Intensive Care Medicine (CVK, CCM), Charité-Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany; Klinikum rechts der Isar, Department of Anesthesiology and Intensive Care, School of Medicine, Technical University of Munich, Munich, Germany.
| |
Collapse
|
2
|
Qian B, Shen A, Huang S, Shi H, Long Q, Zhong Y, Qi Z, He X, Zhang Y, Hai W, Wang X, Cui Y, Chen Z, Xuan H, Zhao Q, You Z, Ye X. An Intrinsically Magnetic Epicardial Patch for Rapid Vascular Reconstruction and Drug Delivery. Adv Sci (Weinh) 2023; 10:e2303033. [PMID: 37964406 PMCID: PMC10754083 DOI: 10.1002/advs.202303033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 08/30/2023] [Indexed: 11/16/2023]
Abstract
Myocardial infarction (MI) is a major cause of mortality worldwide. The major limitation of regenerative therapy for MI is poor cardiac retention of therapeutics, which results from an inefficient vascular network and poor targeting ability. In this study, a two-layer intrinsically magnetic epicardial patch (MagPatch) prepared by 3D printing with biocompatible materials like poly (glycerol sebacate) (PGS) is designed, poly (ε-caprolactone) (PCL), and NdFeB. The two-layer structure ensured that the MagPatch multifariously utilized the magnetic force for rapid vascular reconstruction and targeted drug delivery. MagPatch accumulates superparamagnetic iron oxide (SPION)-labelled endothelial cells, instantly forming a ready-implanted organization, and rapidly reconstructs a vascular network anastomosed with the host. In addition, the prefabricated vascular network within the MagPatch allowed for the efficient accumulation of SPION-labelled therapeutics, amplifying the therapeutic effects of cardiac repair. This study defined an extendable therapeutic platform for vascularization-based targeted drug delivery that is expected to assist in the progress of regenerative therapies in clinical applications.
Collapse
Affiliation(s)
- Bei Qian
- Department of Cardiovascular Surgery, Ruijin HospitalShanghai Jiaotong University School of MedicineShanghai200025China
| | - Ao Shen
- State Key Laboratory for Modification of Chemical Fibers and Polymer MaterialsCollege of Materials Science and EngineeringInstitute of Functional MaterialsResearch Base of Textile Materials for Flexible Electronics and Biomedical Applications (China Textile Engineering Society)Shanghai Engineering Research Center of Nano‐Biomaterials and Regenerative MedicineDonghua UniversityShanghai201620China
| | - Shixing Huang
- Department of Cardiovascular Surgery, Ruijin HospitalShanghai Jiaotong University School of MedicineShanghai200025China
| | - Hongpeng Shi
- Department of Cardiovascular Surgery, Ruijin HospitalShanghai Jiaotong University School of MedicineShanghai200025China
| | - Qiang Long
- Department of Cardiovascular Surgery, Ruijin HospitalShanghai Jiaotong University School of MedicineShanghai200025China
| | - Yiming Zhong
- Department of Cardiovascular Surgery, Ruijin HospitalShanghai Jiaotong University School of MedicineShanghai200025China
| | - Zhaoxi Qi
- Department of Cardiovascular Surgery, Ruijin HospitalShanghai Jiaotong University School of MedicineShanghai200025China
| | - Xiaojun He
- Department of Cardiovascular Surgery, Ruijin HospitalShanghai Jiaotong University School of MedicineShanghai200025China
| | - Yecen Zhang
- Department of Cardiovascular Surgery, Ruijin HospitalShanghai Jiaotong University School of MedicineShanghai200025China
| | - Wangxi Hai
- Department of Nuclear Medicine, Ruijin HospitalShanghai Jiaotong University School of MedicineShanghai200025China
| | - Xinming Wang
- Department of Cardiovascular Surgery, Ruijin HospitalShanghai Jiaotong University School of MedicineShanghai200025China
| | - Yanna Cui
- Department of Pharmacology and Chemical BiologyShanghai Jiaotong University School of MedicineShanghai200000China
| | - Ziheng Chen
- School of Mechatronics Engineering and AutomationShanghai UniversityShanghai200000China
| | - Huixia Xuan
- State Key Laboratory for Modification of Chemical Fibers and Polymer MaterialsCollege of Materials Science and EngineeringInstitute of Functional MaterialsResearch Base of Textile Materials for Flexible Electronics and Biomedical Applications (China Textile Engineering Society)Shanghai Engineering Research Center of Nano‐Biomaterials and Regenerative MedicineDonghua UniversityShanghai201620China
| | - Qiang Zhao
- Department of Cardiovascular Surgery, Ruijin HospitalShanghai Jiaotong University School of MedicineShanghai200025China
| | - Zhengwei You
- State Key Laboratory for Modification of Chemical Fibers and Polymer MaterialsCollege of Materials Science and EngineeringInstitute of Functional MaterialsResearch Base of Textile Materials for Flexible Electronics and Biomedical Applications (China Textile Engineering Society)Shanghai Engineering Research Center of Nano‐Biomaterials and Regenerative MedicineDonghua UniversityShanghai201620China
| | - Xiaofeng Ye
- Department of Cardiovascular Surgery, Ruijin HospitalShanghai Jiaotong University School of MedicineShanghai200025China
| |
Collapse
|
3
|
Franco-Obregón A. Harmonizing Magnetic Mitohormetic Regenerative Strategies: Developmental Implications of a Calcium-Mitochondrial Axis Invoked by Magnetic Field Exposure. Bioengineering (Basel) 2023; 10:1176. [PMID: 37892906 PMCID: PMC10604793 DOI: 10.3390/bioengineering10101176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Revised: 10/05/2023] [Accepted: 10/08/2023] [Indexed: 10/29/2023] Open
Abstract
Mitohormesis is a process whereby mitochondrial stress responses, mediated by reactive oxygen species (ROS), act cumulatively to either instill survival adaptations (low ROS levels) or to produce cell damage (high ROS levels). The mitohormetic nature of extremely low-frequency electromagnetic field (ELF-EMF) exposure thus makes it susceptible to extraneous influences that also impinge on mitochondrial ROS production and contribute to the collective response. Consequently, magnetic stimulation paradigms are prone to experimental variability depending on diverse circumstances. The failure, or inability, to control for these factors has contributed to the existing discrepancies between published reports and in the interpretations made from the results generated therein. Confounding environmental factors include ambient magnetic fields, temperature, the mechanical environment, and the conventional use of aminoglycoside antibiotics. Biological factors include cell type and seeding density as well as the developmental, inflammatory, or senescence statuses of cells that depend on the prior handling of the experimental sample. Technological aspects include magnetic field directionality, uniformity, amplitude, and duration of exposure. All these factors will exhibit manifestations at the level of ROS production that will culminate as a unified cellular response in conjunction with magnetic exposure. Fortunately, many of these factors are under the control of the experimenter. This review will focus on delineating areas requiring technical and biological harmonization to assist in the designing of therapeutic strategies with more clearly defined and better predicted outcomes and to improve the mechanistic interpretation of the generated data, rather than on precise applications. This review will also explore the underlying mechanistic similarities between magnetic field exposure and other forms of biophysical stimuli, such as mechanical stimuli, that mutually induce elevations in intracellular calcium and ROS as a prerequisite for biological outcome. These forms of biophysical stimuli commonly invoke the activity of transient receptor potential cation channel classes, such as TRPC1.
Collapse
Affiliation(s)
- Alfredo Franco-Obregón
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119228, Singapore; ; Tel.: +65-6777-8427 or +65-6601-6143
- Institute of Health Technology and Innovation (iHealthtech), National University of Singapore, Singapore 117599, Singapore
- Biolonic Currents Electromagnetic Pulsing Systems Laboratory (BICEPS), National University of Singapore, Singapore 117599, Singapore
- NUS Centre for Cancer Research (N2CR), Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117597, Singapore
- Healthy Longevity Translational Research Programme, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 119228, Singapore
- Department of Physiology, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117593, Singapore
- Nanomedicine Translational Research Programme, Centre for NanoMedicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore 117544, Singapore
| |
Collapse
|
4
|
Wang Y, Zhao ZG, Chai Z, Fang JC, Chen M. Electromagnetic field and cardiovascular diseases: A state-of-the-art review of diagnostic, therapeutic, and predictive values. FASEB J 2023; 37:e23142. [PMID: 37650634 DOI: 10.1096/fj.202300201rr] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2023] [Revised: 07/20/2023] [Accepted: 08/02/2023] [Indexed: 09/01/2023]
Abstract
Despite encouraging advances in early diagnosis and treatment, cardiovascular diseases (CVDs) remained a leading cause of morbidity and mortality worldwide. Increasing evidence has shown that the electromagnetic field (EMF) influences many biological processes, which has attracted much attention for its potential therapeutic and diagnostic modalities in multiple diseases, such as musculoskeletal disorders and neurodegenerative diseases. Nonionizing EMF has been studied as a therapeutic or diagnostic tool in CVDs. In this review, we summarize the current literature ranging from in vitro to clinical studies focusing on the therapeutic potential (external EMF) and diagnostic potential (internal EMF generated from the heart) of EMF in CVDs. First, we provided an overview of the therapeutic potential of EMF and associated mechanisms in the context of CVDs, including cardiac arrhythmia, myocardial ischemia, atherosclerosis, and hypertension. Furthermore, we investigated the diagnostic and predictive value of magnetocardiography in CVDs. Finally, we discussed the critical steps necessary to translate this promising approach into clinical practice.
Collapse
Affiliation(s)
- Yan Wang
- Laboratory of Heart Valve Disease, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Zhen-Gang Zhao
- Laboratory of Heart Valve Disease, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Zheng Chai
- Laboratory of Heart Valve Disease, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| | - Jian-Cheng Fang
- School of Instrumentation Science and Opto-Electronics Engineering, Beihang University, Beijing, China
| | - Mao Chen
- Laboratory of Heart Valve Disease, West China Hospital, Sichuan University, Chengdu, Sichuan, China
- Department of Cardiology, West China Hospital, Sichuan University, Chengdu, Sichuan, China
| |
Collapse
|
5
|
González-Isaza P, Sánchez-Borrego R, Lugo Salcedo F, Rodríguez N, Vélez Rizo D, Fusco I, Callarelli S. Pulsed Magnetic Stimulation for Stress Urinary Incontinence and Its Impact on Sexuality and Health. Medicina (Kaunas) 2022; 58. [PMID: 36556922 DOI: 10.3390/medicina58121721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 11/21/2022] [Accepted: 11/22/2022] [Indexed: 11/25/2022]
Abstract
It is becoming increasingly common that patients' preferences move towards non-surgical approaches, such as pulsed magnetic stimulation, for female stress urinary incontinence. OBJECTIVE We evaluated the efficacy and safety of a device that uses electromagnetic technology to treat urinary incontinence, with an emphasis on health-related quality of life. METHODS A total of 47 female subjects from 18 to 80 years old were enrolled. After block randomization, treatment consisted of 2 pulsed planar magnetic stimulation sessions per week for 4 weeks (8 sessions). Validated questionnaires: Female Sexual Function Index, International Consultation on Incontinence Questionnaire for Urinary Incontinence: Short Form, and Pelvic Floor Bothersome. Follow-ups were performed at weeks 1, 9, and 14. RESULTS The present study is one of the first clinical trials published evaluating the efficacy and safety of the electromagnetism-based device with flat configuration in patients with stress urinary incontinence, showing a reduction in PFBQ, ICQSF, and Oxford test scores during follow-up, and significantly at week 14 of follow-up, which implied a favorable impact on clinical outcomes, quality of life, and sexuality. CONCLUSIONS The improved results in the treatment group compared with the simulated group show that pulsed magnetic stimulation is a safe and attractive non-invasive alternative for patients who prefer non-surgical treatments.
Collapse
|
6
|
Weisinger B, Pandey DP, Saver JL, Hochberg A, Bitton A, Doniger GM, Lifshitz A, Vardi O, Shohami E, Segal Y, Reznik Balter S, Djemal Kay Y, Alter A, Prasad A, Bornstein NM. Frequency-tuned electro magnetic field therapy improves post-stroke motor function: A pilot randomized controlled trial. Front Neurol 2022; 13:1004677. [PMID: 36452175 PMCID: PMC9702345 DOI: 10.3389/fneur.2022.1004677] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Accepted: 10/05/2022] [Indexed: 11/15/2023] Open
Abstract
BACKGROUND AND PURPOSE Impaired upper extremity (UE) motor function is a common disability after ischemic stroke. Exposure to extremely low frequency and low intensity electromagnetic fields (ELF-EMF) in a frequency-specific manner (Electromagnetic Network Targeting Field therapy; ENTF therapy) is a non-invasive method available to a wide range of patients that may enhance neuroplasticity, potentially facilitating motor recovery. This study seeks to quantify the benefit of the ENTF therapy on UE motor function in a subacute ischemic stroke population. METHODS In a randomized, sham-controlled, double-blind trial, ischemic stroke patients in the subacute phase with moderately to severely impaired UE function were randomly allocated to active or sham treatment with a novel, non-invasive, brain computer interface-based, extremely low frequency and low intensity ENTF therapy (1-100 Hz, < 1 G). Participants received 40 min of active ENTF or sham treatment 5 days/week for 8 weeks; ~three out of the five treatments were accompanied by 10 min of concurrent physical/occupational therapy. Primary efficacy outcome was improvement on the Fugl-Meyer Assessment - Upper Extremity (FMA-UE) from baseline to end of treatment (8 weeks). RESULTS In the per protocol set (13 ENTF and 8 sham participants), mean age was 54.7 years (±15.0), 19% were female, baseline FMA-UE score was 23.7 (±11.0), and median time from stroke onset to first stimulation was 11 days (interquartile range (IQR) 8-15). Greater improvement on the FMA-UE from baseline to week 4 was seen with ENTF compared to sham stimulation, 23.2 ± 14.1 vs. 9.6 ± 9.0, p = 0.007; baseline to week 8 improvement was 31.5 ± 10.7 vs. 23.1 ± 14.1. Similar favorable effects at week 8 were observed for other UE and global disability assessments, including the Action Research Arm Test (Pinch, 13.4 ± 5.6 vs. 5.3 ± 6.5, p = 0.008), Box and Blocks Test (affected hand, 22.5 ± 12.4 vs. 8.5 ± 8.6, p < 0.0001), and modified Rankin Scale (-2.5 ± 0.7 vs. -1.3 ± 0.7, p = 0.0005). No treatment-related adverse events were reported. CONCLUSIONS ENTF stimulation in subacute ischemic stroke patients was associated with improved UE motor function and reduced overall disability, and results support its safe use in the indicated population. These results should be confirmed in larger multicenter studies. CLINICAL TRIAL REGISTRATION https://clinicaltrials.gov/ct2/show/NCT04039178, identifier: NCT04039178.
Collapse
Affiliation(s)
| | - Dharam P. Pandey
- Manipal Hospital Physiotherapy and Rehabilitation, New Delhi, India
| | - Jeffrey L. Saver
- Department of Neurology, UCLA Comprehensive Stroke and Vascular Neurology Program, David Geffen School of Medicine, University of California, Los Angeles, Los Angeles, CA, United States
| | | | | | | | | | - Ofir Vardi
- BrainQ Technologies, Ltd., Jerusalem, Israel
| | - Esther Shohami
- BrainQ Technologies, Ltd., Jerusalem, Israel
- Hebrew University of Jerusalem, Jerusalem, Israel
| | - Yaron Segal
- BrainQ Technologies, Ltd., Jerusalem, Israel
| | | | | | | | - Atul Prasad
- Department of Neurology, B. L. Kapur Super Specialty Hospital (BLK), National Capital Territory of Delhi, New Delhi, India
| | | |
Collapse
|
7
|
de Pedro Negri AM, Ruiz Prieto MJ, Díaz-Mohedo E, Martín-Valero R. Efficacy of Magnetic Therapy in Pain Reduction in Patients with Chronic Pelvic Pain: A Systematic Review. Int J Environ Res Public Health 2022; 19. [PMID: 35627359 DOI: 10.3390/ijerph19105824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 04/30/2022] [Accepted: 05/06/2022] [Indexed: 12/03/2022]
Abstract
Chronic pelvic pain (CPP), also known as chronic pelvic pain syndrome (CPPS), is a common and painful condition. However, its treatment is still a challenge. The findings about the beneficial effects of electromagnetic therapy provide a new, potentially valid, therapeutic alternative for the management of patients with CPP. Objectives: to analyze the efficacy of magnetic field therapy in pain reduction in patients with CPP and for other variables, such as urinary symptoms and quality of life, as well as to review the evidence, in order to establish an action protocol. A qualitative systematic review was carried out, based on the PRISMA protocol and registered in PROSPERO (CRD42022285428). A search was performed in the PubMed, Medline, Scopus, Cochrane, PEDro, BVS, and WOS databases, including those articles in which the patients suffered from CPP; the study variable was pain, and the intervention was based on the application of magnetic fields. Results: Among the 81 articles found, five clinical trials were considered (with an average score of 7.2 in the PEDro scale), with a total of 278 participants, most of whom presented improvements in perceived pain (p ≤ 0.05), as well as in quality of life (p < 0.05) and urinary symptoms (p = 0.05), evaluated through the NIH-CPSI and VAS scales. The therapy was conducted as a monotherapy or in combination with a pharmacological treatment. There was no common protocol among the different articles. Conclusions: Intervention programs through electromagnetic therapy, on their own or with other therapies, can be effective in patients with CPP.
Collapse
|
8
|
Gözlersüzer Ö, Yalvaç B, Çakıroğlu B. Investigation of the effectiveness of magnetic field therapy in women with urinary incontinence: Literature review. Urologia 2022; 90:51-57. [PMID: 35001756 DOI: 10.1177/03915603211069010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE Magnetic stimulation (MS) provides a novel strategy for the treatment of urinary incontinence (UI), although its efficacy remains uncertain. This systematic review both evaluated the effects of MS treatment on UI and investigated its impacts on female patients' life quality. METHODS A review of the literature that was conducted in EMBASE, PubMed, Google Scholar, and the Cochrane Library (2016-2021) with the search terms; Incontinence of stress OR urge of urination OR Urinary incontinence mixed type. The search was carried out for all randomised controlled trials (RCTs) in English. A manual search has also been conducted for the reference lists of the studies found. Seven studies, with a total of 523 patients (475 patients with SUI), 12 urge urinary incontinence. The study included patients with (UUI) and 36 patients with mixed urinary incontinence (MUI). A total of 10 male patients were excluded from the study. In the included studies, The International Incontinence Questionnaire-Short Form was used to investigate the effects of MS therapy on UI symptoms (ICIQ-SF). RESULTS According to the literature review, MS is an effective therapy option for female patients with UI. Still, to establish the efficacy of MS in this area, more large-scale, high-quality RCTs with extended follow-up periods that use consistent stimulation modalities and evaluate comparable outcomes are needed. CONCLUSION MS treatment leads to an improvement in the symptoms of UI, in addition to an associated Improved quality of life for patients, without any reported side effects, while the longer-term treatment outcomes must be determined by long-term trials.
Collapse
Affiliation(s)
- Özlem Gözlersüzer
- Department of Physical Medicine and Rehabilitation, Hisar Intercontinental Hospital, Istanbul, Turkey
| | - Bestami Yalvaç
- Department of Physical Medicine and Rehabilitation, Hisar Intercontinental Hospital, Istanbul, Turkey
| | - Basri Çakıroğlu
- Department of Urology, Hisar Intercontinental Hospital, Istanbul, Turkey
| |
Collapse
|
9
|
Koczy B, Stołtny T, Pasek J, Leksowska–Pawliczek M, Czech S, Ostałowska A, Kasperczyk S, Białkowska M, Cieślar G. Evaluation of β-endorphin concentration, mood, and pain intensity in men with idiopathic hip osteoarthritis treated with variable magnetic field. Medicine (Baltimore) 2019; 98:e16431. [PMID: 31348243 PMCID: PMC6708614 DOI: 10.1097/md.0000000000016431] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Revised: 06/18/2019] [Accepted: 06/19/2019] [Indexed: 01/26/2023] Open
Abstract
Osteoarthritis is the most frequently diagnosed disease of the musculoskeletal system. Growing number of patients waiting for surgical treatment and the possible negative consequences resulting from long-term pharmacological therapy lead to the search for non-pharmacological methods aimed at alleviating pain and reducing doses of analgesics, among them physical therapy with use of magnetic fields.The study involved 30 men aged 49 to 76 (mean age, 61.7 years) treated for idiopathic osteoarthritis of the hip joint. The subjects were divided into 2 groups (15 patients each) and underwent a cycle of magnetostimulation and magnetoledtherapy procedures, respectively. During the exposure cycle concentrations of β-endorphin were assessed 3 times and the mood was assessed 2 times. In addition, the assessment of pain intensity and the dose of analgesic drugs was performed before and after the end of therapy.Statistically significant increase in plasma β-endorphins concentration was observed in both groups of patients (magnetostimulation-P < .01 vs magnetoledtherapy-P < .001). In the assessment of mood of respondents, no statistically significant differences were found. Significant reduction in intensity of perceived pain was observed in both groups of patients (P < .05). In the group of patients who underwent magnetoledtherapy cycle, the analgesic drug use was significantly lower by 13% (P < .05) as compared with initial values, which was not noted in group of patients who underwent magnetostimulation procedures.The use of magnetic field therapy in the treatment of men with idiopathic osteoarthritis of hip joints causes a statistically significant increase in the concentration of plasma β-endorphins resulting in statistically significant analgesic effect in both magnetostimulation and magnetoledtherapy treated groups of patients, with accompanying decrease of need for analgetic drugs in magnetoledtherapy group, but without any significant changes regarding the patient's mood.
Collapse
Affiliation(s)
- Bogdan Koczy
- District Hospital of Orthopaedics and Trauma Surgery in Piekary Śląskie, Piekary Śląskie
| | - Tomasz Stołtny
- District Hospital of Orthopaedics and Trauma Surgery in Piekary Śląskie, Piekary Śląskie
| | - Jarosław Pasek
- Institute of Physical Education, Tourism and Physiotherapy, Jan Długosz University in Częstochowa, Częstochowa
| | | | - Szymon Czech
- District Hospital of Orthopaedics and Trauma Surgery in Piekary Śląskie, Piekary Śląskie
| | - Alina Ostałowska
- Department of Biochemistry, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia, Katowice, Zabrze
| | - Sławomir Kasperczyk
- Department of Biochemistry, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia, Katowice, Zabrze
| | - Monika Białkowska
- District Hospital of Orthopaedics and Trauma Surgery in Piekary Śląskie, Piekary Śląskie
| | - Grzegorz Cieślar
- Department of Internal Medicine, Angiology and Physical Medicine, School of Medicine with the Division of Dentistry in Zabrze, Medical University of Silesia, Katowice, Bytom, Poland
| |
Collapse
|
10
|
Taradaj J, Ozon M, Dymarek R, Bolach B, Walewicz K, Rosińczuk J. Impact of selected magnetic fields on the therapeutic effect in patients with lumbar discopathy: A prospective, randomized, single-blinded, and placebo-controlled clinical trial. ADV CLIN EXP MED 2018; 27:649-666. [PMID: 29616749 DOI: 10.17219/acem/68690] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
BACKGROUND Interdisciplinary physical therapy together with pharmacological treatment constitute conservative treatment strategies related to low back pain (LBP). There is still a lack of high quality studies aimed at an objective evaluation of physiotherapeutic procedures according to their effectiveness in LBP. OBJECTIVES The aim of this study is to carry out a prospective, randomized, single-blinded, and placebocontrolled clinical trial to evaluate the effectiveness of magnetic fields in discopathy-related LBP. MATERIAL AND METHODS A group of 177 patients was assessed for eligibility based on inclusion and exclusion criteria. In the end, 106 patients were randomly assigned into 5 comparative groups: A (n = 23; magnetic therapy: 10 mT, 50 Hz); B (n = 23; magnetic therapy: 5 mT, 50 Hz); C (n = 20; placebo magnetic therapy); D (n = 20; magnetic stimulation: 49.2 μT, 195 Hz); and E (n = 20; placebo magnetic stimulation). All patients were assessed using tests for pain intensity, degree of disability and range of motion. Also, postural stability was assessed using a stabilographic platform. RESULTS In this study, positive changes in all clinical outcomes were demonstrated in group A (p < 0.05). The most effective clinical effect was observed for pain reduction (p < 0.05), improvement of the range of motion (p < 0.05) and functional ability of the spine (p <0.05). It is also worth noting that the effects in the majority of the measured indicators were mostly short-term (p > 0.05). CONCLUSIONS It was determined that the application of magnetic therapy (10 mT, 50 Hz, 20 min) significantly reduces pain symptoms and leads to an improvement of functional ability in patients with LBP.
Collapse
Affiliation(s)
- Jakub Taradaj
- Department of Physiotherapy Basics, Academy of Physical Education in Katowice, Poland
- College of Rehabilitation Sciences, University of Manitoba in Winnipeg, Canada
| | - Marcin Ozon
- Private Physiotherapy Practice "OzonMedica Clinic", Gorlice, Poland
| | - Robert Dymarek
- Department of Nervous System Diseases, Wroclaw Medical University, Poland
| | - Bartosz Bolach
- Department of Sport Didactics, University School of Physical Education in Wroclaw, Poland
| | - Karolina Walewicz
- Institute of Physiotherapy, Public Higher Medical Professional School in Opole, Poland
| | - Joanna Rosińczuk
- Department of Nervous System Diseases, Wroclaw Medical University, Poland
| |
Collapse
|
11
|
Ciejka E, Skibska B, Gorąca A. [Influence of low frequency magnetic field used in magnetotherapy on interleukin 6 (IL-6) contents in rat heart and brain]. Med Pr 2017; 68:517-523. [PMID: 28584335 DOI: 10.13075/mp.5893.00354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
BACKGROUND The human population is exposed ever more frequently to magnetic fields (MF). This is due to both technological progress and development of the economy as well as to advances made in medical science. That is why the thorough understanding and systematized knowledge about mechanisms by which MF exerts its effects on living organisms play such an important role. In this context the health of MF-exposed people is the subject of particular concern. The aim of the study was to evaluate the effect of extremely low frequency magnetic field (ELFMF) used in magnetotherapy on the concentration of interleukin 6 (IL-6) in rat heart and brain. MATERIAL AND METHODS The male rats were randomly divided into 3 experimental groups: group I - control, without contact with magnetic field; group II - exposed to bipolar, rectangular magnetic field 40 Hz, induction "peak-to-peak" 7 mT 30 min/day for 2 weeks; and group III - exposed to bipolar, rectangular magnetic field 40 Hz, 7 mT 60 min/day for 2 weeks. Concentration of IL-6 in the heart and brain of animals was measured after MF exposure. RESULTS Exposure to ELFMF: 40 Hz, induction "peak-to-peak" 7 mT 30 min/day for 2 weeks caused a significant IL-6 increase in rat hearts compared to the control group (p < 0.05) and a non-significant IL-6 decrease in rat brain. The magnetic field applied for 60 min resulted in non-significant IL-6 increase in rat hearts compared to the control group and significant IL-6 decrease in rat brain (p < 0.05). CONCLUSIONS The influence of magnetic field on inflammation in the body varies depending on the MF parameters and the affected tissues or cells. Med Pr 2017;68(4):517-523.
Collapse
Affiliation(s)
- Elżbieta Ciejka
- Wyższa Szkoła Biznesu i Nauk o Zdrowiu w Łodzi / The Academy of Business Administration and Health Sciences, Łódź, Poland.
| | - Beata Skibska
- Uniwersytet Medyczny w Łodzi / Medical University of Lodz, Łódź, Poland (Zakład Farmacji Aptecznej, Katedra Farmacji Stosowanej / Department of Pharmacy, Department of Applied Pharmacy)
| | - Anna Gorąca
- Uniwersytet Medyczny w Łodzi / Medical University of Lodz, Łódź, Poland (Zakład Fizjologii Krążenia, Katedra Fizjologii Doświadczalnej i Klinicznej / Department of Cardiovascular Physiology, Chair of Experimental and Clinical Physiology)
| |
Collapse
|
12
|
Florian MR, Zotelli VLR, de Sousa MDLR, Polloni LAB. Use of Magnetic Neurostimulator Appliance in Temporomandibular Disorder. J Acupunct Meridian Stud 2017; 10:104-108. [PMID: 28483180 DOI: 10.1016/j.jams.2017.02.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2016] [Revised: 02/17/2017] [Accepted: 02/21/2017] [Indexed: 11/16/2022] Open
Abstract
Temporomandibular disorder (TMD) is ranked the second leading cause of orofacial pain after toothache, and there is no effective standard treatment for all cases. Therefore, much research has been conducted in the therapeutic areas of TMD, such as acupuncture and electrotherapy, for this purpose. The aim of this research was to evaluate application of the neuromagnetic stimulator device Haihua model CD-9, used within the precepts of acupuncture in treating TMD-related pain symptoms and limited mouth opening. Analysis and discussion of this study were based on pain intensity index and range of mouth-opening evaluation before and after each session. Nine patients diagnosed with muscle TMD, referred by the surgery sector of Center Dental Specialties (CEO - I) in Piracicaba-São Paulo participated in this research. Considering the simplicity of the technique and good results obtained, use of this device is suggested as an additional therapeutic tool for relief of TMD symptoms.
Collapse
Affiliation(s)
- Marcelo Rossiti Florian
- CETN/Faculty of Libertas, Sorocaba, Sao Paolo, Brazil; Trainee in the Acupuncture Clinic of the Piracicaba Dental School/UNICAMP, Sao Paolo, Brazil.
| | - Vera Lucia Rasera Zotelli
- Post-Graduation Program in Dentistry, Piracicaba Dental School, State University of Campinas/UNICAMP, Sao Paolo, Brazil
| | | | | |
Collapse
|
13
|
Lim R, Liong ML, Leong WS, Karim Khan NA, Yuen KH. Pulsed Magnetic Stimulation for Stress Urinary Incontinence: 1-Year Followup Results. J Urol 2016; 197:1302-1308. [PMID: 27871927 DOI: 10.1016/j.juro.2016.11.091] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/13/2016] [Indexed: 10/20/2022]
Abstract
PURPOSE Despite significant differences in success rates between surgical and nonsurgical treatments for female stress urinary incontinence, a few cross-sectional surveys showed that most patients still prefer the latter. We evaluated the efficacy of the under studied nonsurgical treatment using pulsed magnetic stimulation for female stress urinary incontinence. MATERIALS AND METHODS This randomized, double-blind, sham controlled study was performed in 120 female subjects at least 21 years old with stress urinary incontinence. Treatment involved pulsed magnetic stimulation for 2 sessions per week for 2 months (16 sessions). After 2 months, subjects could opt for 16 additional sessions regardless of initial randomization. The primary response criterion was a 5-point reduction in the ICIQ-UI SF (International Consultation on Incontinence Questionnaire for Urinary Incontinence-Short Form) score. Key secondary response criteria included objective and subjective cure, supplemented by other secondary criteria. Followups were performed at months 1, 2, 5, 8 and 14. RESULTS At 2 months 45 of 60 subjects (75%) in the active arm vs 13 of 60 (21.7%) in the sham arm were treatment responders (p <0.001). After 2 months 24 subjects (40%) in the active arm and 41 (68%) in the sham arm elected additional active pulsed magnetic stimulation. At 14 months, subjects who received 32 sessions of active pulsed magnetic stimulation had the highest percentage of treatment responders (18 of 24 or 75.0%), followed by those who received 16 sessions (26 of 36 or 72.2% and 28 of 41 or 68.3%) and those who did not receive any active pulsed magnetic stimulation (4 of 19 or 21.1%) (p <0.001). CONCLUSIONS The encouraging long-term response rates show that pulsed magnetic stimulation is an attractive nonsurgical alternative for patients who do not want to undergo surgery.
Collapse
Affiliation(s)
- Renly Lim
- School of Pharmaceutical Sciences, Universiti Sains Malaysia, Penang, Malaysia; School of Pharmacy and Medical Sciences, University of South Australia, Adelaide, South Australia, Australia.
| | - Men Long Liong
- Department of Urology, Island Hospital, Penang, Malaysia
| | - Wing Seng Leong
- Department of Urology, Lam Wah Ee Hospital, Penang, Malaysia
| | | | - Kah Hay Yuen
- School of Pharmaceutical Sciences, Universiti Sains Malaysia, Penang, Malaysia
| |
Collapse
|
14
|
Rick O, von Hehn U, Mikus E, Dertinger H, Geiger G. Magnetic field therapy in patients with cytostatics-induced polyneuropathy: A prospective randomized placebo-controlled phase-III study. Bioelectromagnetics 2016; 38:85-94. [PMID: 27657350 PMCID: PMC5248614 DOI: 10.1002/bem.22005] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2016] [Accepted: 08/20/2016] [Indexed: 01/05/2023]
Abstract
No causal treatment for chemotherapy‐induced peripheral neuropathy (CIPN) is known. Therefore, there is an urgent need to develop a therapy for CIPN. Only scarce clinical data are available concerning magnetic field therapy (MFT) in this context. We conducted a unicentric, randomized, double‐blind, placebo‐controlled phase‐III trial of an MFT device versus placebo. In this study, we randomized 44 patients with CIPN to two treatment groups, where 21 patients were treated with MFT (Group 1) and 23 patients received placebo (Group 2). We evaluated the efficacy of MFT at baseline (T1), after 3 weeks of study treatment (T2), and after 3 months of study treatment (T3). The primary endpoint was nerve conduction velocity (NCV), while secondary endpoints were the Common Toxicity Criteria (CTCAE) score and the Pain Detect End Score at T3. Seventeen of the patients in Group 1 and 14 patients in Group 2 completed the respective study treatment. The primary endpoint, significant improvement of NCV at T3, was achieved by MFT (P = 0.015), particularly for sensory neurotoxicity of the peroneal nerve. Also, in respect to the secondary endpoints, significant improvement (P = 0.04) was achieved in terms of the patients’ subjectively perceived neurotoxicity (CTCAE score), but not of neuropathic pain (P = 0.11). From data in the randomized study presented here, a positive effect on the reduction of neurotoxicity can be assumed for the MFT device. Patients with sensory neurotoxicity in the lower limbs, especially, should therefore be offered this therapy. Bioelectromagnetics. 38:85–94, 2017. © 2016 The Authors. Bioelectromagnetics published by Wiley Periodicals, Inc.
Collapse
Affiliation(s)
- Oliver Rick
- Klinik Reinhardshöhe, Medical Center of Cancer Rehabilitation, Bad Wildungen, Germany
| | | | - Eberhard Mikus
- Klinik Reinhardshöhe, Medical Center of Cancer Rehabilitation, Bad Wildungen, Germany
| | - Hermann Dertinger
- Karlsruher Institute of Technology (KIT), Eggenstein-Leopoldshafen, Germany
| | - Georg Geiger
- Klinik Reinhardshöhe, Medical Center of Cancer Rehabilitation, Bad Wildungen, Germany
| |
Collapse
|
15
|
Suszyński K, Marcol W, Szajkowski S, Pietrucha-Dutczak M, Cieślar G, Sieroń A, Lewin-Kowalik J. Variable spatial magnetic field influences peripheral nerves regeneration in rats. Electromagn Biol Med 2013; 33:198-205. [PMID: 23781984 DOI: 10.3109/15368378.2013.801351] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Generator of spatial magnetic field is one of most recent achievements among the magnetostimulators. This apparatus allows to obtain the rotating magnetic field. This new method may be more effective than other widely used techniques of magnetostimulation and magnetotherapy. We investigated the influence of alternating, spatial magnetic field on the regeneration of the crushed rat sciatic nerves. Functional and morphological evaluations were used. After crush injury of the right sciatic nerve, Wistar C rats (n = 80) were randomly divided into four groups (control and three experimental). The experimental groups (A, B, C) were exposed (20 min/day, 5 d/week, 4 weeks) to alternating spatial magnetic field of three different intensities. Sciatic Functional Index (SFI) and tensometric assessments were performed every week after nerve crush. Forty-eight hours before the sacrificing of animals, DiI (1,1'-di-octadecyl-3,3,3',3'-tetramethyloindocarbocyanine perchlorate) was applied 5 mm distally to the crush site. Collected nerves and dorsal root ganglia (DRG) were subjected to histological and immunohistochemical staining. The survival rate of DRG neurons was estimated. Regrowth and myelination of the nerves was examined. The results of SFI and tensometric assessment showed improvement in all experimental groups as compared to control, with best outcome observed in group C, exposed to the strongest magnetic field. In addition, DRG survival rate and nerve regeneration intensity were significantly higher in the C group. Above results indicate that strong spatial alternating magnetic field exerts positive effect on peripheral nerve regeneration and its application could be taken under consideration in the therapy of injured peripheral nerves.
Collapse
Affiliation(s)
- Krzysztof Suszyński
- Department of Physiology, Medical University of Silesia , Katowice , Poland and
| | | | | | | | | | | | | |
Collapse
|