1
|
Plaque Composition as a Predictor of Plaque Ulceration in Carotid Artery Atherosclerosis: The Plaque At RISK Study. AJNR Am J Neuroradiol 2021; 42:144-151. [PMID: 33214179 DOI: 10.3174/ajnr.a6868] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Accepted: 08/09/2020] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Plaque ulceration is a marker of previous plaque rupture. We studied the association between atherosclerotic plaque composition at baseline and plaque ulceration at baseline and follow-up. MATERIALS AND METHODS We included symptomatic patients with a carotid stenosis of <70% who underwent MDCTA and MR imaging at baseline (n = 180). MDCTA was repeated at 2 years (n = 73). We assessed the presence of ulceration using MDCTA. Baseline MR imaging was used to assess the vessel wall volume and the presence and volume of plaque components (intraplaque hemorrhage, lipid-rich necrotic core, and calcifications) and the fibrous cap status. Associations at baseline were evaluated with binary logistic regression and reported with an OR and its 95% CI. Simple statistical testing was performed in the follow-up analysis. RESULTS At baseline, the prevalence of plaque ulceration was 27% (49/180). Increased wall volume (OR = 12.1; 95% CI, 3.5-42.0), higher relative lipid-rich necrotic core (OR = 1.7; 95% CI, 1.3-2.2), higher relative intraplaque hemorrhage volume (OR = 1.7; 95% CI, 1.3-2.2), and a thin-or-ruptured fibrous cap (OR = 3.4; 95% CI, 1.7-6.7) were associated with the presence of ulcerations at baseline. In 8% (6/73) of the patients, a new ulcer developed. Plaques with a new ulceration at follow-up had at baseline a larger wall volume (1.04 cm3 [IQR, 0.97-1.16 cm3] versus 0.86 cm3 [IQR, 0.73-1.00 cm3]; P = .029), a larger relative lipid-rich necrotic core volume (23% [IQR, 13-31%] versus 2% [IQR, 0-14%]; P = .002), and a larger relative intraplaque hemorrhage volume (14% [IQR, 8-24%] versus 0% [IQR, 0-5%]; P < .001). CONCLUSIONS Large atherosclerotic plaques and plaques with intraplaque hemorrhage and lipid-rich necrotic cores were associated with plaque ulcerations at baseline and follow-up.
Collapse
|
2
|
Simultaneous Morphological and Flow Imaging Enabled by Megahertz Intravascular Doppler Optical Coherence Tomography. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:1535-1544. [PMID: 31725370 DOI: 10.1109/tmi.2019.2948258] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
We demonstrate three-dimensional intravascular flow imaging compatible with routine clinical image acquisition workflow by means of megahertz (MHz) intravascular Doppler Optical Coherence Tomography (OCT). The OCT system relies on a 1.1 mm diameter motorized imaging catheter and a 1.5 MHz Fourier Domain Mode Locked (FDML) laser. Using a post processing method to compensate the drift of the FDML laser output, we can resolve the Doppler phase shift between two adjoining OCT A-line datasets. By interpretation of the velocity field as measured around the zero phase shift, the flow direction at specific angles can be qualitatively estimated. Imaging experiments were carried out in phantoms, micro channels, and swine coronary artery in vitro at a speed of 600 frames/s. The MHz wavelength sweep rate of the OCT system allows us to directly investigate flow velocity of up to 37.5 cm/s while computationally expensive phase-unwrapping has to be applied to measure such high speed using conventional OCT system. The MHz sweep rate also enables a volumetric Doppler imaging even with a fast pullback at 40 mm/s. We present the first simultaneously recorded 3D morphological images and Doppler flow profiles. Flow pattern estimation and three-dimensional structural reconstruction of entire coronary artery are achieved using a single OCT pullback dataset.
Collapse
|
3
|
An MRI-based method to register patient-specific wall shear stress data to histology. PLoS One 2019; 14:e0217271. [PMID: 31170183 PMCID: PMC6553699 DOI: 10.1371/journal.pone.0217271] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Accepted: 04/27/2019] [Indexed: 11/18/2022] Open
Abstract
Wall shear stress (WSS), the frictional force exerted on endothelial cells by blood flow, is hypothesised to influence atherosclerotic plaque growth and composition. We developed a methodology for image registration of MR and histology images of advanced human carotid plaques and corresponding WSS data, obtained by MRI and computational fluid dynamics. The image registration method requires four types of input images, in vivo MRI, ex vivo MRI, photographs of transversally sectioned plaque tissue and histology images. These images are transformed to a shared 3D image domain by applying a combination of rigid and non-rigid registration algorithms. Transformation matrices obtained from registration of these images are used to transform subject-specific WSS data to the shared 3D image domain as well. WSS values originating from the 3D WSS map are visualised in 2D on the corresponding lumen locations in the histological sections and divided into eight radial segments. In each radial segment, the correlation between WSS values and plaque composition based on histological parameters can be assessed. The registration method was successfully applied to two carotid endarterectomy specimens. The resulting matched contours from the imaging modalities had Hausdorff distances between 0.57 and 0.70 mm, which is in the order of magnitude of the in vivo MRI resolution. We simulated the effect of a mismatch in the rigid registration of imaging modalities on WSS results by relocating the WSS data with respect to the stack of histology images. A 0.6 mm relocation altered the mean WSS values projected on radial bins on average by 0.59 Pa, compared to the output of original registration. This mismatch of one image slice did not change the correlation between WSS and plaque thickness. In conclusion, we created a method to investigate correlations between WSS and plaque composition.
Collapse
|
4
|
The effect of the heart rate lowering drug Ivabradine on hemodynamics in atherosclerotic mice. Sci Rep 2018; 8:14014. [PMID: 30228313 PMCID: PMC6143553 DOI: 10.1038/s41598-018-32458-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Accepted: 09/05/2018] [Indexed: 12/27/2022] Open
Abstract
The heart rate lowering drug Ivabradine was shown to improve cardiac outcome in patients with previous heart failure. However, in patients without heart failure, no beneficial effect of Ivabradine was observed. Animal studies suggested a preventive effect of Ivabradine on atherosclerosis which was due to an increase in wall shear stress (WSS), the blood flow-induced frictional force exerted on the endothelium, triggering anti-inflammatory responses. However, data on the effect of Ivabradine on WSS is sparse. We aim to study the effect of Ivabradine on (i) the 3D WSS distribution over a growing plaque and (ii) plaque composition. We induced atherosclerosis in ApoE-/- mice by placing a tapered cast around the right common carotid artery (RCCA). Five weeks after cast placement, Ivabradine was administered via drinking water (15 mg/kg/day) for 2 weeks, after which the RCCA was excised for histology analyses. Before and after Ivabradine treatment, animals were imaged with Doppler Ultrasound to measure blood velocity. Vessel geometry was obtained using contrast-enhanced micro-CT. Time-averaged WSS during systole, diastole and peak WSS was subsequently computed. Ivabradine significantly decreased heart rate (459 ± 28 bpm vs. 567 ± 32 bpm, p < 0.001). Normalized peak flow significantly increased in the Ivabradine group (124.2% ± 40.5% vs. 87.3% ± 25.4%, p < 0.05), reflected by an increased normalized WSS level during systole (110.7% ± 18.4% vs. 75.4% ± 24.6%, p < 0.05). However, plaque size or composition including plaque area, relative necrotic core area and macrophage content were not altered in mice treated with Ivabradine compared to controls. We conclude that increased WSS in response to Ivabradine treatment did not affect plaque progression in a murine model.
Collapse
|
5
|
Multiline 3D beamforming using micro-beamformed datasets for pediatric transesophageal echocardiography. ACTA ACUST UNITED AC 2018; 63:075015. [DOI: 10.1088/1361-6560/aab45e] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
6
|
Temporal and spatial changes in wall shear stress during atherosclerotic plaque progression in mice. ROYAL SOCIETY OPEN SCIENCE 2018; 5:171447. [PMID: 29657758 PMCID: PMC5882682 DOI: 10.1098/rsos.171447] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2017] [Accepted: 02/07/2018] [Indexed: 05/03/2023]
Abstract
Wall shear stress (WSS) is involved in atherosclerotic plaque initiation, yet its role in plaque progression remains unclear. We aimed to study (i) the temporal and spatial changes in WSS over a growing plaque and (ii) the correlation between WSS and plaque composition, using animal-specific data in an atherosclerotic mouse model. Tapered casts were placed around the right common carotid arteries (RCCA) of ApoE-/- mice. At 5, 7 and 9 weeks after cast placement, RCCA geometry was reconstructed using contrast-enhanced micro-CT. Lumen narrowing was observed in all mice, indicating the progression of a lumen intruding plaque. Next, we determined the flow rate in the RCCA of each mouse using Doppler Ultrasound and computed WSS at all time points. Over time, as the plaque developed and further intruded into the lumen, absolute WSS significantly decreased. Finally at week 9, plaque composition was histologically characterized. The proximal part of the plaque was small and eccentric, exposed to relatively lower WSS. Close to the cast a larger and concentric plaque was present, exposed to relatively higher WSS. Lower WSS was significantly correlated to the accumulation of macrophages in the eccentric plaque. When pooling data of all animals, correlation between WSS and plaque composition was weak and no longer statistically significant. In conclusion, our data showed that in our mouse model absolute WSS strikingly decreased during disease progression, which was significantly correlated to plaque area and macrophage content. Besides, our study demonstrates the necessity to analyse individual animals and plaques when studying correlations between WSS and plaque composition.
Collapse
|
7
|
Real-time volumetric lipid imaging in vivo by intravascular photoacoustics at 20 frames per second. BIOMEDICAL OPTICS EXPRESS 2017; 8:943-953. [PMID: 28270995 PMCID: PMC5330573 DOI: 10.1364/boe.8.000943] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2016] [Revised: 01/10/2017] [Accepted: 01/11/2017] [Indexed: 05/03/2023]
Abstract
Lipid deposition can be assessed with combined intravascular photoacoustic/ultrasound (IVPA/US) imaging. To date, the clinical translation of IVPA/US imaging has been stalled by a low imaging speed and catheter complexity. In this paper, we demonstrate imaging of lipid targets in swine coronary arteries in vivo, at a clinically useful frame rate of 20 s-1. We confirmed image contrast for atherosclerotic plaque in human samples ex vivo. The system is on a mobile platform and provides real-time data visualization during acquisition. We achieved an IVPA signal-to-noise ratio of 20 dB. These data show that clinical translation of IVPA is possible in principle.
Collapse
|
8
|
Live Observation of Atherosclerotic Plaque Disruption in Apolipoprotein E-Deficient Mouse. Ultrasound Int Open 2016; 1:E67-71. [PMID: 27689156 DOI: 10.1055/s-0035-1565092] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
Abstract
AIM The actual occurrence of spontaneous plaque rupture in mice has been a matter of debate. We report on an in vivo observation of the actual event of possible plaque disruption in a living ApoE(-/-) mouse. METHODS AND RESULTS During live contrast-enhanced ultrasonography of a 50-week-old ApoE(-/-) male mouse, symptoms suggesting plaque disruption in the brachiocephalic artery were observed. Histological analysis confirmed the presence of advanced atherosclerotic lesions with dissections and intraplaque hemorrhage in the affected brachiocephalic trunk, pointing towards plaque rupture as the cause of the observed event. However, we did not detect a luminal thrombus or cap rupture, which is a key criterion for plaque rupture in human atherosclerosis. CONCLUSION This study reports the real-time occurrence of a possible plaque rupture in a living ApoE(-/-) mouse.
Collapse
|
9
|
Intraplaque Hemorrhage and the Plaque Surface in Carotid Atherosclerosis: The Plaque At RISK Study (PARISK). AJNR Am J Neuroradiol 2015; 36:2127-33. [PMID: 26251429 DOI: 10.3174/ajnr.a4414] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2014] [Accepted: 03/14/2015] [Indexed: 12/21/2022]
Abstract
BACKGROUND AND PURPOSE An important characteristic of vulnerable plaque, intraplaque hemorrhage, may predict plaque rupture. Plaque rupture can be visible on noninvasive imaging as a disruption of the plaque surface. We investigated the association between intraplaque hemorrhage and disruption of the plaque surface. MATERIALS AND METHODS We selected the first 100 patients of the Plaque At RISK study, an ongoing prospective noninvasive plaque imaging study in patients with mild-to-moderate atherosclerotic lesions in the carotid artery. In carotid artery plaques, disruption of the plaque surface (defined as ulcerated plaques and/or fissured fibrous cap) and intraplaque hemorrhage were assessed by using MDCTA and 3T MR imaging, respectively. We used a χ(2) test and multivariable logistic regression to assess the association between intraplaque hemorrhage and disrupted plaque surface. RESULTS One hundred forty-nine carotid arteries in 78 patients could be used for the current analyses. Intraplaque hemorrhage and plaque ulcerations were more prevalent in symptomatic compared with contralateral vessels (hemorrhage, 38% versus 11%; P < .001; and ulcerations, 27% versus 7%; P = .001). Fissured fibrous cap was more prevalent in symptomatic compared with contralateral vessels (13% versus 4%; P = .06). After adjustment for age, sex, diabetes mellitus, and degree of stenosis, intraplaque hemorrhage was associated with disrupted plaque surface (OR, 3.13; 95% CI, 1.25-7.84) in all vessels. CONCLUSIONS Intraplaque hemorrhage is associated with disruption of the plaque surface in patients with a carotid artery stenosis of <70%. Serial studies are needed to investigate whether intraplaque hemorrhage indeed increases the risk of plaque rupture and subsequent ischemic stroke during follow-up.
Collapse
|
10
|
Carotid plaque elasticity estimation using ultrasound elastography, MRI, and inverse FEA - A numerical feasibility study. Med Eng Phys 2015; 37:801-7. [PMID: 26130603 DOI: 10.1016/j.medengphy.2015.06.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2014] [Revised: 06/02/2015] [Accepted: 06/07/2015] [Indexed: 12/13/2022]
Abstract
The material properties of atherosclerotic plaques govern the biomechanical environment, which is associated with rupture-risk. We investigated the feasibility of noninvasively estimating carotid plaque component material properties through simulating ultrasound (US) elastography and in vivo magnetic resonance imaging (MRI), and solving the inverse problem with finite element analysis. 2D plaque models were derived from endarterectomy specimens of nine patients. Nonlinear neo-Hookean models (tissue elasticity C1) were assigned to fibrous intima, wall (i.e., media/adventitia), and lipid-rich necrotic core. Finite element analysis was used to simulate clinical cross-sectional US strain imaging. Computer-simulated, single-slice in vivo MR images were segmented by two MR readers. We investigated multiple scenarios for plaque model elasticity, and consistently found clear separations between estimated tissue elasticity values. The intima C1 (160 kPa scenario) was estimated as 125.8 ± 19.4 kPa (reader 1) and 128.9 ± 24.8 kPa (reader 2). The lipid-rich necrotic core C1 (5 kPa) was estimated as 5.6 ± 2.0 kPa (reader 1) and 8.5 ± 4.5 kPa (reader 2). A scenario with a stiffer wall yielded similar results, while realistic US strain noise and rotating the models had little influence, thus demonstrating robustness of the procedure. The promising findings of this computer-simulation study stimulate applying the proposed methodology in a clinical setting.
Collapse
|
11
|
Quantitative contrast-enhanced ultrasound of intraplaque neovascularization in patients with carotid atherosclerosis. ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2015; 36:154-161. [PMID: 24824762 DOI: 10.1055/s-0034-1366410] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
PURPOSE Intraplaque neovascularization (IPN) is an increasingly studied marker of the vulnerable atherosclerotic plaque, and contrast-enhanced ultrasound (CEUS) is an in vivo imaging technique for the assessment of IPN. The purpose of this study was to test novel quantification methods for the detection of carotid IPN using CEUS. MATERIALS AND METHODS 25 patients with established carotid atherosclerosis underwent bilateral carotid CEUS using a Philips iU-22 ultrasound system with an L9 - 3 transducer. Visual scoring of IPN was performed using a 3-point score. Quantification of IPN was performed using novel custom developed software. In short, regions of interest were drawn over the atherosclerotic plaques. After motion compensation, several IPN features were calculated. Statistical analysis was performed using Spearman's rho. Reproducibility of the quantification features was calculated using intra-class correlation coefficients and mean differences between calculations. RESULTS 45 carotid arteries were available for the quantification of IPN. The quantification of IPN was feasible in all 45 carotid plaques. The IPN area, IPN area ratio and neovessel count had a good correlation with the visual IPN score (respectively ρ = 0.719, ρ = 0.538, ρ = 0.474 all p < 0.01). The intra-observer and inter-observer agreement was good to excellent (p < 0.01). The intra-observer and inter-observer variability was low. CONCLUSION The quantification of carotid IPN on CEUS is feasible and provides multiple features on carotid IPN. Accurate quantitative assessment of IPN may be important to recognize and to monitor changes during therapy in vulnerable atherosclerotic plaques.
Collapse
|
12
|
Intravital microscopy of localized stem cell delivery using microbubbles and acoustic radiation force. Biotechnol Bioeng 2014; 112:220-7. [PMID: 25088405 DOI: 10.1002/bit.25337] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2014] [Revised: 06/13/2014] [Accepted: 07/07/2014] [Indexed: 01/11/2023]
Abstract
The use of stem cells for the repair of damaged cardiac tissue after a myocardial infarction holds great promise. However, a common finding in experimental studies is the low number of cells delivered at the area at risk. To improve the delivery, we are currently investigating a novel delivery platform in which stem cells are conjugated with targeted microbubbles, creating echogenic complexes dubbed StemBells. These StemBells vibrate in response to incoming ultrasound waves making them susceptible to acoustic radiation force. The acoustic force can then be employed to propel circulating StemBells from the centerline of the vessel to the wall, facilitating localized stem cell delivery. In this study, we investigate the feasibility of manipulating StemBells acoustically in vivo after injection using a chicken embryo model. Bare stem cells or unsaturated stem cells (<5 bubbles/cell) do not respond to ultrasound application (1 MHz, peak negative acoustical pressure P_ = 200 kPa, 10% duty cycle). However, stem cells which are fully saturated with targeted microbubbles (>30 bubbles/cell) can be propelled toward and arrested at the vessel wall. The mean translational velocities measured are 61 and 177 μm/s for P- = 200 and 450 kPa, respectively. This technique therefore offers potential for enhanced and well-controlled stem cell delivery for improved cardiac repair after a myocardial infarction.
Collapse
|
13
|
Plaque at RISK (PARISK): Prospective Multicenter Study to Improve Diagnosis of High-Risk Carotid Plaques. Int J Stroke 2013; 9:747-54. [DOI: 10.1111/ijs.12167] [Citation(s) in RCA: 64] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Background Patients with symptomatic carotid artery stenosis are at high risk for recurrent stroke. To date, the decision to perform carotid endarterectomy in patients with a recent cerebrovascular event is mainly based on degree of stenosis of the ipsilateral carotid artery. However, additional atherosclerotic plaque characteristics might be better predictors of stroke, allowing for more precise selection of patients for carotid endarterectomy. Aims and hypothesis We investigate the hypothesis that the assessment of carotid plaque characteristics with magnetic resonance imaging, multidetector-row computed tomography angiography, ultrasonography, and transcranial Doppler, either alone or in combination, may improve identification of a subgroup of patients with <70% carotid artery stenosis with an increased risk of recurrent stroke. Methods The Plaque At RISK (PARISK) study is a prospective multicenter cohort study of patients with recent (<3 months) neurological symptoms due to ischemia in the territory of the carotid artery and < 70% ipsilateral carotid artery stenosis who are not scheduled for carotid endarterectomy or stenting. At baseline, 300 patients will undergo magnetic resonance imaging, multidetector-row computed tomography angiography, and ultrasonography examination of the carotid arteries. In addition, magnetic resonance imaging of the brain, ambulatory transcranial Doppler recording of the middle cerebral artery and blood withdrawal will be performed. After two-years, imaging will be repeated in 150 patients. All patients undergo a follow-up brain magnetic resonance imaging, and there will be regular clinical follow-up until the end of the study. Study outcomes The combined primary end-point contains ipsilateral recurrent ischemic stroke or transient ischemic attack or new ipsilateral ischemic brain lesions on follow-up brain magnetic resonance imaging.
Collapse
|
14
|
Abstract
Second harmonic imaging is currently accepted as the standard in commercial echographic systems. A new imaging technique, coined as superharmonic imaging (SHI), combines the third till the fifth harmonics, arising during nonlinear sound propagation. It could further enhance the resolution and quality of echographic images. To meet the bandwidth requirement for SHI a dedicated phased array has been developed: a low frequency subarray, intended for transmission, interleaved with a high frequency subarray, used in reception. As the bandwidth of the elements is limited, the spectral gaps in between the harmonics cause multiple (ghost) reflection artifacts. A dual-pulse frequency compounding method aims at suppressing those artifacts at a price of a reduced frame rate. In this study we explore a possibility of performing frequency compounding within a single transmission. The traditional frequency compounding method suppresses the ripples by consecutively emitting two short Gaussian bursts with a slightly different center frequency. In the newly proposed method, the transmit aperture is divided into two parts: the first half is used to send a pulse at the lower center frequency, while the other half simultaneously transmits at a slightly higher center frequency. The suitability of the protocol for medical imaging applications in terms of the steering capabilities was performed in a simulation study with INCS and the hydrophone measurements. Moreover, an experimental study was carried out to find the optimal parameters for the clinical imaging protocol. The latter was subsequently used to obtain the images of a tissue mimicking phantom containing strongly reflecting wires. Additionally, the images of a human heart in the parasternal projection were acquired. The scanning aperture with the developed protocol amounts to approximately 90°, which is sufficient to capture the cardiac structures in the standard anatomical projections. The theoretically estimated and experimentally measured grating lobe levels are equal to -28.3 dB and -35.9 dB, respectively. A considerable improvement in the axial resolution of the SHI component (0.73 mm) at -6 dB in comparison with the third harmonic (2.23 mm) was observed. A similar comparison in terms of the lateral resolution slightly favored the superharmonic component by 0.2 mm. Additionally, the images of the tissue mimicking phantom exhibited the absence of the multiple reflection artifacts. The in-vivo acquisition allows one to clearly observe the dynamic of the mitral valve leaflets. The new method is equally effective in eliminating the ripple artifacts associated with SHI as the dual-pulse technique, while the full frame rate is maintained.
Collapse
|
15
|
Chirp resonance spectroscopy of single lipid-coated microbubbles using an "acoustical camera". THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2012; 132:EL470-EL475. [PMID: 23231210 DOI: 10.1121/1.4767448] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
An acoustical method was developed to study the resonance of single lipid-coated microbubbles. The response of 127 SonoVue microbubbles to a swept sine excitation between 0.5 and 5.5 MHz with a peak acoustic pressure amplitude of 70 kPa was measured by means of a 25 MHz probing wave. The relative amplitude modulation in the signal scattered in response to the probing wave is approximately equal to the radial strain induced by the swept sine excitation. An average damping coefficient of 0.33 and an average resonance frequency of 2.5 MHz were measured. Microbubbles experienced an average peak radial strain of 20%.
Collapse
|
16
|
Abstract
Most techniques for contrast-enhanced ultrasound imaging require linear propagation to detect nonlinear scattering of contrast agent microbubbles. Waveform distortion due to nonlinear propagation impairs their ability to distinguish microbubbles from tissue. As a result, tissue can be misclassified as microbubbles, and contrast agent concentration can be overestimated; therefore, these artifacts can significantly impair the quality of medical diagnoses. Contrary to biological tissue, lipid-coated gas microbubbles used as a contrast agent allow the interaction of two acoustic waves propagating in opposite directions (counter-propagation). Based on that principle, we describe a strategy to detect microbubbles that is free from nonlinear propagation artifacts. In vitro images were acquired with an ultrasound scanner in a phantom of tissue-mimicking material with a cavity containing a contrast agent. Unlike the default mode of the scanner using amplitude modulation to detect microbubbles, the pulse sequence exploiting counter-propagating wave interaction creates no pseudoenhancement behind the cavity in the contrast image.
Collapse
|
17
|
Vasa vasorum and molecular imaging of atherosclerotic plaques using nonlinear contrast intravascular ultrasound. Neth Heart J 2012; 15:77-80. [PMID: 18604278 DOI: 10.1007/bf03085959] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
|
18
|
Abstract
Subharmonic (SH) emission from the ultrasound contrast agent (UCA) is of interest since it is produced only by the UCA and not by tissue, opposite to harmonic imaging modes where both tissue and microbubble show harmonics. In this work, the use of the self-demodulation (S-D) signal as a means of microbubble excitation at the SH frequency to enhance the SH emission of UCA is studied. The S-D wave is a low-frequency signal produced by the weak nonlinear propagation of an ultrasound wave. It is proportional to the second time derivative of the squared envelope of the transmitted signal. A diluted population of BR14 UCA (Bracco Research SA, Geneva, Switzerland) was insonified by a 10 MHz transducer focused at 76 mm firing bursts with different envelopes, durations and peak pressure amplitudes. The center frequency of the S-D signal changes from low frequencies (around 0.5 MHz) toward the transmitted frequency (10 MHz) by modifying the envelope function from gaussian to rectangular. For 6 and 20 transmitted cycles, the SH response is enhanced up to 25 and 22 dB, respectively, when using a rectangular envelope instead of a gaussian one. The experimental results are confirmed by the numerical simulation. The effects of the excitation duration and pressure amplitude are also studied. This study shows that a suitable design of the envelope of the transmit excitation to generate a S-D signal at the SH frequency can enhance the SH emission of UCA, and the SH imaging is feasible at high frequencies with a shorter transmit burst (six-cycle) and low acoustic pressure (∼100 KPa).
Collapse
|
19
|
Combined optical coherence tomography and intravascular ultrasound radio frequency data analysis for plaque characterization. Classification accuracy of human coronary plaques in vitro. Int J Cardiovasc Imaging 2010; 26:843-50. [PMID: 20396951 PMCID: PMC2991172 DOI: 10.1007/s10554-010-9631-2] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2009] [Accepted: 04/05/2010] [Indexed: 11/26/2022]
Abstract
This study was performed to characterize coronary plaque types by optical coherence tomography (OCT) and intravascular ultrasound (IVUS) radiofrequency (RF) data analysis, and to investigate the possibility of error reduction by combining these techniques. Intracoronary imaging methods have greatly enhanced the diagnostic capabilities for the detection of high-risk atherosclerotic plaques. IVUS RF data analysis and OCT are two techniques focusing on plaque morphology and composition. Regions of interest were selected and imaged with OCT and IVUS in 50 sections, from 14 human coronary arteries, sectioned post-mortem from 14 hearts of patients dying of non-cardiovascular causes. Plaques were classified based on IVUS RF data analysis (VH-IVUSTM), OCT and the combination of those. Histology was the benchmark. Imaging with both modalities and coregistered histology was successful in 36 sections. OCT correctly classified 24; VH-IVUS 25, and VH-IVUS/OCT combined, 27 out of 36 cross-sections. Systematic misclassifications in OCT were intimal thickening classified as fibroatheroma in 8 cross-sections. Misclassifications in VH-IVUS were mainly fibroatheroma as intimal thickening in 5 cross-sections. Typical image artifacts were found to affect the interpretation of OCT data, misclassifying intimal thickening as fibroatheroma or thin-cap fibroatheroma. Adding VH-IVUS to OCT reduced the error rate in this study.
Collapse
|
20
|
Doppler flow velocity waveforms in the embryonic chicken heart at developmental stages corresponding to 5-8 weeks of human gestation. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2009; 33:638-644. [PMID: 19434670 DOI: 10.1002/uog.v33:6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVES To obtain Doppler velocity waveforms from the early embryonic chicken heart by means of ultrasound biomicroscopy and to compare these waveforms at different stages of embryonic development. METHODS We collected cardiac waveforms using high-frequency Doppler ultrasound with a 55-MHz transducer at Hamburger-Hamilton (HH) stages 18, 21 and 23, which are comparable to humans at 5 to 8 weeks of gestation. Waveforms were obtained at the inflow tract, the primitive left ventricle, the primitive right ventricle and at the outflow tract in 10 different embryos per stage. M-mode recordings were collected to study opening and closure of the cushions. By exploring the temporal relationship between the waveforms, using a secondary Doppler device, cardiac cycle events were outlined. RESULTS Our results demonstrate that stage- and location-dependent intracardiac blood flow velocity waveforms can be obtained in the chicken embryo. The blood flow profiles assessed at the four locations in the embryonic heart demonstrated an increase in peak velocity with advancing developmental stage. In the primitive ventricle the 'passive' (P) filling peak decreased whereas the 'active' (A) filling peak increased, resulting in a decrease in P to A ratio with advancing developmental stage. M-mode recordings demonstrated that the fractional closure time of the atrioventricular cushions increased from 20% at stage HH 18 to 60% at stage HH 23. CONCLUSION High-frequency ultrasound biomicroscopy can be used to define flow velocity waveforms in the embryonic chicken heart. This may contribute to an understanding of Doppler signals derived from valveless embryonic human hearts at 5 to 8 weeks of gestation, prior to septation.
Collapse
|
21
|
Doppler flow velocity waveforms in the embryonic chicken heart at developmental stages corresponding to 5-8 weeks of human gestation. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2009; 33:638-644. [PMID: 19434670 DOI: 10.1002/uog.6362] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
OBJECTIVES To obtain Doppler velocity waveforms from the early embryonic chicken heart by means of ultrasound biomicroscopy and to compare these waveforms at different stages of embryonic development. METHODS We collected cardiac waveforms using high-frequency Doppler ultrasound with a 55-MHz transducer at Hamburger-Hamilton (HH) stages 18, 21 and 23, which are comparable to humans at 5 to 8 weeks of gestation. Waveforms were obtained at the inflow tract, the primitive left ventricle, the primitive right ventricle and at the outflow tract in 10 different embryos per stage. M-mode recordings were collected to study opening and closure of the cushions. By exploring the temporal relationship between the waveforms, using a secondary Doppler device, cardiac cycle events were outlined. RESULTS Our results demonstrate that stage- and location-dependent intracardiac blood flow velocity waveforms can be obtained in the chicken embryo. The blood flow profiles assessed at the four locations in the embryonic heart demonstrated an increase in peak velocity with advancing developmental stage. In the primitive ventricle the 'passive' (P) filling peak decreased whereas the 'active' (A) filling peak increased, resulting in a decrease in P to A ratio with advancing developmental stage. M-mode recordings demonstrated that the fractional closure time of the atrioventricular cushions increased from 20% at stage HH 18 to 60% at stage HH 23. CONCLUSION High-frequency ultrasound biomicroscopy can be used to define flow velocity waveforms in the embryonic chicken heart. This may contribute to an understanding of Doppler signals derived from valveless embryonic human hearts at 5 to 8 weeks of gestation, prior to septation.
Collapse
|
22
|
A study of coronary artery rotational motion with dense scale-space optical flow in intravascular ultrasound. Phys Med Biol 2009; 54:1397-418. [DOI: 10.1088/0031-9155/54/6/002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
23
|
High shear stress influences plaque vulnerability Part of the data presented in this paper were published in Stroke 2007;38:2379-81. Neth Heart J 2008; 16:280-3. [PMID: 18711619 PMCID: PMC2516295 DOI: 10.1007/bf03086163] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
Shear stress of the blood at the vessel wall plays an important role in many processes in the cardiovascular system primarily focused on the regulation of vessel lumen and wall dimensions. There is ample evidence that atherosclerotic plaques are generated at low shear stress regions in the cardiovascular system, while high shear stress regions are protected. In the course of plaque progression, advanced plaques start to encroach into the lumen, and thereby start to experience high shear stress at the endothelium. Until now the consequences of high shear stress working at the endothelium of an advanced plaque are unknown. As high shear stress influences tissue regression, we hypothesised that high shear stress can destabilise the plaque by cap weakening leading to ulceration. We investigated this hypothesis in a magnetic resonance imaging (MRI) dataset of a 67-year-old woman with a plaque in the carotid artery at baseline and an ulcer at ten-month follow-up. The lumen, plaque components (lipid/necrotic core, intraplaque haemorrhage) and ulcer were reconstructed three dimensionally and the geometry at baseline was used for shear stress calculation using computational fluid dynamics. Correlation of the change in plaque composition with the shear stress at baseline showed that the ulcer was generated exclusively at the high shear stress location. In this serial MRI study we found plaque ulceration at the high shear stress location of a protruding plaque in the carotid artery. Our data suggest that high shear stress influences plaque vulnerability and therefore may become a potential parameter for predicting future events. (Neth Heart J 2008;16:280-3.).
Collapse
|
24
|
A numerical model to predict abdominal aortic aneurysm expansion based on local wall stress and stiffness. Med Biol Eng Comput 2008; 46:1121-7. [PMID: 18521644 DOI: 10.1007/s11517-008-0358-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2006] [Accepted: 05/18/2008] [Indexed: 11/29/2022]
Abstract
Aneurysms of the abdominal aorta enlarge until rupture occurs. We assume that this is the result of remodelling to restore wall stress. We developed a numerical model to predict aneurysm expansion based on this assumption. In addition, we obtained aneurysm geometry of 11 patients from computed tomography angiographic images to obtain patient specific calculations. The assumption of a wall stress related expansion indeed resulted in a series of local expansions, adjusting global geometry in an exponential fashion similar as in patients. Furthermore, it revealed that location of peak wall stress changed over time. The assumptions of this model are discussed in detail in this manuscript, and the implications are related to literature findings.
Collapse
|
25
|
Time continuous detection of the left ventricular long axis and the mitral valve plane in 3-D echocardiography. ULTRASOUND IN MEDICINE & BIOLOGY 2008; 34:196-207. [PMID: 17935871 DOI: 10.1016/j.ultrasmedbio.2007.07.016] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2007] [Revised: 06/04/2007] [Accepted: 07/25/2007] [Indexed: 05/25/2023]
Abstract
Automated segmentation approaches for the left ventricle (LV) in 3-D echocardiography (3DE) often rely on manual initialization. So far, little effort has been put into automating the initialization procedure to get to a fully automatic segmentation approach. We propose a fully automatic method for the detection of the LV long axis (LAX) and the mitral valve plane (MVP) over the full cardiac cycle, for the initialization of segmentation algorithms in 3DE. Our method exploits the cyclic motion of the LV and therefore detects salient structures in a time-continuous way. Probabilities to candidate LV center points are assigned through a Hough transform for circles. The LV LAX is detected by combining dynamic programming detections on these probabilities in 3-D and 2D + time to obtain a time continuous solution. Subsequently, the mitral valve plane is detected in a projection of the data on a plane through the previously detected LAX. The method easily adjusts to different acquisition routines and combines robustness with good accuracy and low computational costs. Automatic detection was evaluated using patient data acquired with the fast rotating ultrasound (FRU) transducer (n=11 patients) and with the Philips Sonos 7500 ultrasound system (Philips Medical Systems, Andover, MA, USA), with the X4 matrix transducer (n=14 patients). For the FRU-transducer data, the LAX was estimated with a distance error of 2.85+/-1.70 mm (mean+/-SD) and an angle of 5.25+/-3.17 degrees; the mitral valve plane was estimated with a distance of -1.54+/-4.31 mm. For the matrix data, these distances were 1.96+/-1.30 mm with an angle error of 5.95+/-2.11 and -1.66+/-5.27 mm for the mitral valve plane. These results confirm that the method is very suitable for automatic detection of the LV LAX and MVP. It provides a basis for further automatic exploration of the LV and could therefore serve as a replacement of manual initialization of 3-D segmentation approaches.
Collapse
|
26
|
P2A-6 Automatic Segmentation of the Left Ventricle in 3D Echocardiography Using Active Appearance Models. ACTA ACUST UNITED AC 2007. [DOI: 10.1109/ultsym.2007.372] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
27
|
A numerical study on the influence of vulnerable plaque composition on intravascular thermography measurements. Phys Med Biol 2006; 51:5875-87. [PMID: 17068370 DOI: 10.1088/0031-9155/51/22/010] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Intracoronary thermography is a technique that measures lumen wall temperatures for vulnerable plaque detection. In this paper the influence of vulnerable plaque composition on lumen wall temperatures was studied numerically. Concerning the vulnerable plaque heat generation, the location of the heat source and its heat production were varied. Concerning the heat transfer, the thermal properties of the lipid core and the location of the vasa vasorum were studied. The heat source location was the main determinant of the lumen wall temperature distribution. The strongest effect was noted when the heat producing macrophages were located in the shoulder region leading to focal spots of higher temperature. The maximal lumen wall temperature was mainly determined by the heat production of the macrophages and the cooling effect of blood. The insulating properties of the lipid core increased lumen wall temperatures when the heat source was located in the cap and the presence of vasa vasorum lowered the temperatures. These results show that the lumen wall temperature distribution is influenced by vulnerable plaque composition and that intracoronary thermography techniques require a high spatial resolution. To be able to couple temperature measurements to plaque vulnerability, intracoronary thermography needs to be combined with an imaging modality.
Collapse
|
28
|
Remote non-invasive stereoscopic imaging of blood vessels: first in-vivo results of a new multispectral contrast enhancement technology. Ann Biomed Eng 2006; 34:1870-8. [PMID: 17048103 PMCID: PMC1705509 DOI: 10.1007/s10439-006-9198-1] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2005] [Accepted: 09/01/2006] [Indexed: 10/31/2022]
Abstract
We describe a contactless optical technique selectively enhancing superficial blood vessels below variously pigmented intact human skin by combining images in different spectral bands. Two CMOS-cameras, with apochromatic lenses and dual-band LED-arrays, simultaneously streamed Left (L) and Right (R) image data to a dual-processor PC. Both cameras captured color images within the visible range (VIS, 400-780 nm) and grey-scale images within the near infrared range (NIR, 910-920 nm) by sequentially switching between LED-array emission bands. Image-size-settings of 1280 x 1024 for VIS & 640 x 512 for NIR produced 12 cycles/s (1 cycle = 1 VIS L&R-pair + 1 NIR L&R-pair). Decreasing image-size-settings (640 x 512 for VIS and 320 x 256 for NIR) increased camera-speed to 25 cycles/s. Contrasts from below the tissue surface were algorithmically distinguished from surface shadows, reflections, etc. Thus blood vessels were selectively enhanced and back-projected into the stereoscopic VIS-color-image using either a 3D-display or conventional shutter glasses. As a first usability reconnaissance we applied this custom-built mobile stereoscopic camera for several clinical settings:* blood withdrawal;* vein inspection in dark skin;* vein detection through iodide;* varicose vein and nevi pigmentosum inspection. Our technique improves blood vessel visualization compared to the naked eye, and supports depth perception.
Collapse
|
29
|
Shear stress is associated with markers of plaque vulnerability and MMP-9 activity. EUROINTERVENTION 2006; 2:250-256. [PMID: 19755269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
BACKGROUND Vulnerable plaque has been associated with local macrophage accumulation and local high matrix metalloproteinase-2 (MMP-2) and MMP-9 activity. Since shear stress is a known local modulator of plaque location, we have determined whether local shear stress was associated with local plaque composition and with local MMP activity. METHODS AND RESULTS In 17 NZW rabbits plaque was generated by denudation of the infrarenal aorta over a region of 5 cm and feeding them a high cholesterol diet for 2 months. After 2 months, a motorised IVUS pullback of the infrarenal aorta was performed with a 40 MHz IVUS catheter (CVIS, Boston Scientific, USA). IVUS derived vessel wall-lumen contours were reconstructed in 3D with in-house developed software. These reconstructions served as an input for a computational fluid dynamics technique, from which the 3-D shear stress field was calculated. Plaque regions were divided in 5 regions (n=8) to identify the location of highest macrophage accumulation or selected on basis of shear stress to identify whether high shear stress selects macrophage accumulation (n=8). In a second series, shear stress values were used to select regions -containing both latent and active MMP-2 and MMP-9. Segments were sectioned with a microtome and stained for smooth muscle cells (SMC), macrophages (MPhi) and collagen (COL). MPhi, displayed the highest density upstream of the plaque (6.9+/-2.4%, p<0.05), while SMC accumulated downstream (74.8+/-1.9%) of the plaque. High shear stress was associated with MPhi accumulation and MMP-9 activity (p<0.05). CONCLUSION Upstream location of macrophages in plaques is associated with high shear stress and MMP-9 accumulation. These findings are discussed in relation to rheological theories reported previously in atherosclerosis.
Collapse
|
30
|
High frequency nonlinear scattering from a micrometer to submicrometer sized lipid encapsulated contrast agent. ULTRASOUND IN MEDICINE & BIOLOGY 2006; 32:569-77. [PMID: 16616602 DOI: 10.1016/j.ultrasmedbio.2006.01.002] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2005] [Revised: 12/27/2005] [Accepted: 01/05/2006] [Indexed: 05/08/2023]
Abstract
An experimental lipid encapsulated contrast agent comprised substantially of micrometer to submicrometer diameter bubbles was evaluated for its capacity to produce nonlinear scattering in response to high transmit frequencies. Agent characterization experiments were conducted at transmit frequencies of 20 and 30 MHz with bandwidths of 5, 15 and 25% using a broadband focused PVDF transducer. The presence of subharmonic energy was observed for all bandwidths at a wide range of pressures (0.49 to 5.7 MPa and 0.45 to 4.5 MPa for the 20 and 30 MHz cases, respectively). Distinct ultraharmonics were observed only in the 5% bandwidth cases. Second harmonic energy was also present, but this was at least partly due to nonlinear propagation, as indicated by linear scatterer signals. Evidence of destruction was found only at higher peak negative pressures (e.g., >2 MPa for 30 MHz 5% bandwidth pulse). The results suggest that small lipid bubble formulations may be useful for the purposes of high frequency nonlinear contrast imaging.
Collapse
|
31
|
Detecting broken struts of a Björk-Shiley heart valve using ultrasound: a feasibility study. ULTRASOUND IN MEDICINE & BIOLOGY 2006; 32:503-12. [PMID: 16616597 DOI: 10.1016/j.ultrasmedbio.2005.12.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2005] [Revised: 12/12/2005] [Accepted: 12/22/2005] [Indexed: 05/08/2023]
Abstract
The Björk-Shiley (BScc) mechanical heart valve has extensively been used in surgery from 1979 to 1986. There is, compared with equivalent valve types, increased occurrence of unexpected mechanical failure of the outlet strut of the valve, with a high incidence of mortality, when it occurs. Many approaches have been attempted to noninvasively determine BScc valve integrity. None of the approaches resulted in adequate assessment, mostly due to a lack of either sensitivity or specificity demonstrated in in vitro and/or in vivo studies. In our study we analyze leg movement of the BScc valves outlet strut during the cardiac cycle with ultrasound. For a broken strut, the movement of both legs will be significantly different, whereas the difference will be negligible for an intact strut. BScc valves were mounted in the mitral position in an in vitro pulse duplicator system. A focused single-element transducer was used to direct ultrasound on a leg of the outlet strut. Correlation-based time delay estimation was used to estimate differences in time of flight of the outlet strut echoes to determine outlet strut leg movement. The movement of an intact valve and a valve with a single-leg fracture with both ends grating against each other (SLF), the most difficult fracture to diagnose, has been studied. The results showed no significant difference in movement between both legs of the outlet strut of the intact BScc valve (amplitude of movement 9.2 microm +/- 0.1 microm). Whereas for the defective valve, the amplitude of movement of the broken leg of the SLF valve was 12 microm +/- 1.6 microm vs. 8.6 microm +/- 0.1 microm for the intact leg. In conclusion, the proposed method has shown to be feasible in vitro and has potentials for in vivo detection of BScc valve outlet strut fracture.
Collapse
|
32
|
Contactless multiple wavelength photoplethysmographic imaging: a first step toward "SpO2 camera" technology. Ann Biomed Eng 2005; 33:1034-41. [PMID: 16133912 DOI: 10.1007/s10439-005-5763-2] [Citation(s) in RCA: 111] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2004] [Accepted: 03/03/2005] [Indexed: 10/25/2022]
Abstract
We describe a route toward contactless imaging of arterial oxygen saturation (SpO2) distribution within tissue, based upon detection of a two-dimensional matrix of spatially resolved optical plethysmographic signals at different wavelengths. As a first step toward SpO2-imaging we built a monochrome CMOS-camera with apochromatic lens and 3lambda-LED-ringlight (lambda1 = 660 nm, lambda2 = 810 nm, lambda3 = 940 nm; 100 LEDs lambda(-1)). We acquired movies at three wavelengths while simultaneously recording ECG and respiration for seven volunteers. We repeated this experiment for one volunteer at increased frame rate, additionally recording the pulse wave of a pulse oximeter. Movies were processed by dividing each image frame into discrete Regions of Interest (ROIs), averaging 10 x 10 raw pixels each. For each ROI, pulsatile variation over time was assigned to a matrix of ROI-pixel time traces with individual Fourier spectra. Photoplethysmograms correlated well with respiration reference traces at three wavelengths. Increased frame rates revealed weaker pulsations (main frequency components 0.95 and 1.9 Hz) superimposed upon respiration-correlated photoplethysmograms, which were heartbeat-related at three wavelengths. We acquired spatially resolved heartbeat-related photoplethysmograms at multiple wavelengths using a remote camera. This feasibility study shows potential for non-contact 2-D imaging reflection-mode pulse oximetry. Clinical devices, however, require further development.
Collapse
|
33
|
Abstract
Blood-flow-induced shear stress acting on the arterial wall is of paramount importance in vascular biology. Endothelial cells sense shear stress and largely control its value in a feedback-control loop by adapting the arterial dimensions to blood flow. Nevertheless, to allow for variations in arterial geometry, such as bifurcations, shear stress control is modified at certain eccentrically located sites to let it remain at near-zero levels. In the presence of risk factors for atherosclerosis, low shear stress contributes to local endothelial dysfunction and eccentric plaque build up, but normal-to-high shear stress is atheroprotective. Initially, lumen narrowing is prevented by outward vessel remodeling. Maintenance of a normal lumen and, by consequence, a normal shear stress distribution, however, prolongs local unfavorable low shear stress conditions and aggravates eccentric plaque growth. While undergoing such growth, eccentric plaques at preserved lumen locations experience increased tensile stress at their shoulders making them prone to fissuring and thrombosis. Consequent loss of the plaque-free wall by coverage with thrombus and new tissue may bring shear-stress-controlled lumen preservation to an end. This change causes shear stress to increase, which as a new condition may transform the lesion into a rupture-prone vulnerable plaque. We present a discussion of the role of shear stress, in setting the stage for the generation of rupture-prone, vulnerable plaques, and how this may be prevented.
Collapse
|
34
|
Effect of vessel curvature on Doppler derived velocity profiles and fluid flow. ULTRASOUND IN MEDICINE & BIOLOGY 2005; 31:663-71. [PMID: 15866416 DOI: 10.1016/j.ultrasmedbio.2005.01.011] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2004] [Revised: 01/20/2005] [Accepted: 01/27/2005] [Indexed: 05/02/2023]
Abstract
Side-branches and curvatures in the arterial tree yield deviations from the axial oriented velocity. Velocity or volume flow estimates based on the assumption that flow is axially oriented are of limited value at these sites. This article evaluates information obtainable by using a multigate Doppler ultrasound (US) instrument used with curved phantoms, which resemble the human coronary arteries. The comparison of experimental velocity data with data provided by an accurate computational fluid dynamics (CFD) method shows differences in the range of 4 to 11% for four curvatures with different radii. Multigate data are also used to estimate the volume flow in the curved segments at different experimental conditions. An error lower than 15% is obtained, to be compared with a 24% error obtained by assuming a parabolic velocity profile. In particular, it is shown that the residual error is not related to the small deviation of the velocity vectors from the axial direction due to the presence of secondary velocity components, which are found to be of magnitude less than 10% with respect to the axial velocity component.
Collapse
|
35
|
Temperature distribution in atherosclerotic coronary arteries: influence of plaque geometry and flow (a numerical study). Phys Med Biol 2004; 49:4447-62. [PMID: 15552410 DOI: 10.1088/0031-9155/49/19/001] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Intravascular coronary thermography is a method that may detect vulnerable, atherosclerotic plaques and is currently evaluated in a clinical setting. Active macrophages or enzymatic heat releasing processes in vulnerable plaques may act as heat sources. To better understand the parameters of influence on thermographic measurements, numerical simulations have been performed on a model of a coronary artery segment containing a heat source. Heat source parameters and flow were varied to study their influence on temperatures at the lumen wall. Maximal temperature differences at the lumen wall increased when the source volume increased and they differ with the source geometry. The simulations showed that blood flow acts as a coolant to the lumen wall. Blood flow decreased maximal temperatures depending on the source geometry, source volume and the maximal flow velocity. Influence of flow was highest for circumferentially extended sources, up to a factor 3.7, and lowest for longitudinally extended sources, down to a factor 1.9. When cap thickness increased, maximal temperatures decreased and the influence of flow increased. This study shows that correct interpretation of intravascular thermographic measurements requires data on the flow and on the morphologic characteristics of the atherosclerotic plaque.
Collapse
|
36
|
Imaging of coronary atherosclerosis and identification of the vulnerable plaque. Neth Heart J 2003; 11:347-358. [PMID: 25696244 PMCID: PMC2499949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/04/2023] Open
Abstract
Identification of the vulnerable plaque responsible for the occurrence of acute coronary syndromes and acute coronary death is a prerequisite for the stabilisation of this vulnerable plaque. Comprehensive coronary atherosclerosis imaging in clinical practice should involve visualisation of the entire coronary artery tree and characterisation of the plaque, including the three-dimensional morphology of the plaque, encroachment of the plaque on the vessel lumen, the major tissue components of the plaque, remodelling of the vessel and presence of inflammation. Obviously, no single diagnostic modality is available that provides such comprehensive imaging and unfortunately no diagnostic tool is available that unequivocally identifies the vulnerable plaque. The objective of this article is to discuss experience with currently available diagnostic modalities for coronary atherosclerosis imaging. In addition, a number of evolving techniques will be briefly discussed.
Collapse
|
37
|
Abstract
Intravascular ultrasound (IVUS) elastography is a technique that assesses the local strain in the vessel wall and plaque. The strain is an important parameter for characterization of different plaque components. These regions are related to plaque vulnerability. IVUS elastography was validated in vitro using human coronary and femoral arteries. These experiments were performed on specimens that were stored frozen and measured at room temperature for practical issues. The aim of this study is to determine the influence of freezing and measuring the tissues at room temperature (23 degrees C instead of 37 degrees C) on the elastic properties. Four human coronary, one carotid and one femoral arteries were first measured at 23 degrees C and next at 37 degrees C. Additionally they were stored at -80 degrees C for up to 24 h and finally measured at 23 degrees C. Acquisitions at intraluminal pressures of 80 and 100 mmHg were performed using an EndoSonics 20 MHz Visions catheter. Elastograms were determined from the IVUS rf-data (sampled at 100 MHz in 12 bits) that were obtained from a digital interface. Qualitative and quantitative analysis of the elastograms obtained from fresh and frozen specimens measured at 23 degrees C reveals that storage of the specimen at -80 degrees C has no significant influence. In vitro experiments can be performed at room temperature after storage of the tissue at -80 degrees C without significant affection of the information with respect to measuring fresh ex vivo material at body temperature.
Collapse
|
38
|
Experimental characterization of fundamental and second harmonic beams for a high-frequency ultrasound transducer. ULTRASOUND IN MEDICINE & BIOLOGY 2002; 28:635-646. [PMID: 12079700 DOI: 10.1016/s0301-5629(02)00498-2] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
In the diagnostic frequency range, nonlinear imaging has been shown to improve image contrast and decrease artefacts. The extension of these techniques to high-frequency imaging (>15 MHz) was investigated. The second harmonic beam at 40 MHz of a high-frequency focused transducer (aperture 6 mm, focal distance 10 mm, f-number 1.67) was measured experimentally in water, in transmission and pulse-echo, and compared with the fundamental beams at 20 MHz and 40 MHz. Measurements were performed at peak negative pressures of 0.8 to 4.7 MPa. Transmission measurements were performed with a custom hydrophone with a 25microm spot size to limit beam averaging. Over the range of peak negative pressures, the transmitted harmonic (40 MHz) beam had an average lateral beam width (-3 dB) of 77 microm and an average depth-of-field of 0.93 mm, whereas the fundamental beam had a corresponding beam width of 137 microm and a depth-of-field of 1.59 mm. The harmonic beam showed a 3-dB decrease in side lobe levels. Preliminary second harmonic images of mouse tissue in vitro are presented and compared to fundamental imaging at 20 and 40 MHz.
Collapse
|
39
|
Morphological and mechanical information of coronary arteries obtained with intravascular elastography; feasibility study in vivo. Eur Heart J 2002; 23:405-13. [PMID: 11846498 DOI: 10.1053/euhj.2001.2806] [Citation(s) in RCA: 124] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
AIMS Plaque composition is a major determinant of coronary related clinical syndromes. In vitro experiments on human coronary and femoral arteries have demonstrated that different plaque types were detectable with intravascular ultrasound elastography. The aim of this study was to investigate the feasibility of applying intravascular elastography during interventional catheterization procedures. METHODS AND RESULTS Data were acquired in patients (n=12) during PTCA procedures with an EndoSonics InVision echoapparatus equipped with radiofrequency output. The systemic pressure was used to strain the tissue, and the strain was determined using cross-correlation analysis of sequential frames. A likelihood function was determined to obtain the frames with minimal motion of the catheter in the lumen, since motion of the catheter prevents reliable strain estimation. Minimal motion was observed near end-diastole. Reproducible strain estimates were obtained within one pressure cycle and over several pressure cycles. Validation of the results was limited to the information provided by the echogram. Strain in calcified material (0.20%+/-0.07) was lower (P<0.001) than in non-calcified tissue (0.51%+/-0.20). CONCLUSION In vivo intravascular elastography is feasible. Significantly higher strain values were found in non-calcified plaques than in calcified plaques.
Collapse
|