1
|
Chavez-Pineda OG, Rodriguez-Moncayo R, Gonzalez-Suarez AM, Guevara-Pantoja PE, Maravillas-Montero JL, Garcia-Cordero JL. Portable platform for leukocyte extraction from blood using sheath-free microfluidic DLD. Lab Chip 2024; 24:2575-2589. [PMID: 38646820 DOI: 10.1039/d4lc00132j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/23/2024]
Abstract
Leukocyte count is routinely performed for diagnostic purposes and is rapidly emerging as a significant biomarker for a wide array of diseases. Additionally, leukocytes have demonstrated considerable promise in novel cell-based immunotherapies. However, the direct retrieval of leukocytes from whole blood is a significant challenge due to their low abundance compared to erythrocytes. Here, we introduce a microfluidic-based platform that isolates and recovers leukocytes from diluted whole blood in a single step. Our platform utilizes a novel, sheathless method to initially sediment and focus blood cells into a dense stream while flowing through a tubing before entering the microfluidic device. A hexagonal-shaped structure, patterned at the device's inlet, directs all the blood cells against the channel's outer walls. The focused cells are then separated based on their size using the deterministic lateral displacement (DLD) microfluidic technique. We evaluated various parameters that could influence leukocyte separation, including different focusing structures (assessed both computationally and experimentally), the orientation of the tubing-chip interface, the effects of blood sample hematocrit (dilution), and flow rate. Our device demonstrated the ability to isolate leukocytes from diluted blood with a separation efficiency of 100%, a recovery rate of 76%, and a purity of 80%, while maintaining a cell viability of 98%. The device operates for over 30 min at a flow rate of 2 μL min-1. Furthermore, we developed a handheld pressure controller to drive fluid flow, enhancing the operability of our platform outside of central laboratories and enabling near-patient testing. Our platform can be integrated with downstream cell-based assays and analytical methods that require high leukocyte purity (80%), ranging from cell counting to diagnostics and cell culture applications.
Collapse
Affiliation(s)
- Oriana G Chavez-Pineda
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Roberto Rodriguez-Moncayo
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Alan M Gonzalez-Suarez
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Pablo E Guevara-Pantoja
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Jose L Maravillas-Montero
- Red de Apoyo a la Investigación, Universidad Nacional Autónoma de México e Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán, Mexico City14080, Mexico
| | - Jose L Garcia-Cordero
- Laboratory of Microtechnologies Applied to Biomedicine (LMAB), Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
- Institute of Human Biology (IHB), Roche Pharma Research and Early Development, Roche Innovation Center Basel, Basel 4058, Switzerland.
| |
Collapse
|
2
|
de Hoyos-Vega JM, Gonzalez-Suarez AM, Cedillo-Alcantar DF, Stybayeva G, Matveyenko A, Malhi H, Garcia-Cordero JL, Revzin A. Microfluidic 3D hepatic cultures integrated with a droplet-based bioanalysis unit. Biosens Bioelectron 2024; 248:115896. [PMID: 38176252 PMCID: PMC10916504 DOI: 10.1016/j.bios.2023.115896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 11/03/2023] [Accepted: 11/27/2023] [Indexed: 01/06/2024]
Abstract
A common challenge in microfluidic cell cultures has to do with analysis of cell function without replacing a significant fraction of the culture volume and disturbing local concentration gradients of signals. To address this challenge, we developed a microfluidic cell culture device with an integrated bioanalysis unit to enable on-chip analysis of picoliter volumes of cell-conditioned media. The culture module consisted of an array of 140 microwells with a diameter of 300 m which were made low-binding to promote organization of cells into 3D spheroids. The bioanalysis module contained a droplet generator unit, 15 micromechanical valves and reservoirs loaded with reagents. Each 0.8 nL droplet contained an aliquot of conditioned media mixed with assay reagents. The use of microvalves allowed us to load enzymatic assay and immunoassay into sequentially generated droplets for detection of glucose and albumin, respectively. As a biological application of the microfluidic device, we evaluated hormonal stimulation and glucose consumption of hepatic spheroids. To mimic physiological processes occurring during feeding and fasting, hepatic spheroids were exposed to pancreatic hormones, insulin or glucagon. The droplet-based bioanalysis module was used to measure uptake or release of glucose upon hormonal stimulation. In the future, we intend to use this microfluidic device to mimic and measure pathophysiological processes associated with hepatic insulin resistance and diabetes in the context of metabolic syndrome.
Collapse
Affiliation(s)
- Jose M de Hoyos-Vega
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | | | - Diana F Cedillo-Alcantar
- Laboratory of Microtechnologies Applied to Biomedicine, Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Gulnaz Stybayeva
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Aleksey Matveyenko
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Harmeet Malhi
- Division of Gastroenterology and Hepatology, Mayo Clinic, MN, USA
| | - Jose L Garcia-Cordero
- Laboratory of Microtechnologies Applied to Biomedicine, Centro de Investigación y de Estudios Avanzados (Cinvestav), Monterrey, NL, Mexico
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
3
|
de Hoyos-Vega JM, Yu X, Gonzalez-Suarez AM, Chen S, Mercado-Perez A, Krueger E, Hernandez J, Fedyshyn Y, Druliner BR, Linden DR, Beyder A, Revzin A. Modeling gut neuro-epithelial connections in a novel microfluidic device. Microsyst Nanoeng 2023; 9:144. [PMID: 38025883 PMCID: PMC10643697 DOI: 10.1038/s41378-023-00615-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Revised: 09/22/2023] [Accepted: 09/28/2023] [Indexed: 12/01/2023]
Abstract
The intestinal lumen is filled with diverse chemical and physical stimuli. Intestinal epithelial cells sense these stimuli and signal to enteric neurons which coordinate a range of physiologic processes required for normal digestive tract function. Yet, the neuro-epithelial connections remain poorly resolved, in part because the tools for orchestrating interactions between these cellular compartments are lacking. We describe the development of a two-compartment microfluidic device for co-culturing enteric neurons with intestinal epithelial cells. The device contains epithelial and neuronal compartments connected by microgrooves. The epithelial compartment was designed for cell seeding via injection and confinement of intestinal epithelial cells derived from human intestinal organoids. We demonstrated that organoids planarized effectively and retained epithelial phenotype for over a week. In the second chamber we dissociated and cultured intestinal myenteric neurons including intrinsic primary afferent neurons (IPANs) from transgenic mice that expressed the fluorescent protein tdTomato. IPANs extended projections into microgrooves, surrounded and frequently made contacts with epithelial cells. The density and directionality of neuronal projections were enhanced by the presence of epithelial cells in the adjacent compartment. Our microfluidic device represents a platform that may, in the future, be used to dissect structure and function of neuro-epithelial connections in the gut and other organs (skin, lung, bladder, and others) in health and disease.
Collapse
Affiliation(s)
| | - Xi Yu
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN USA
| | | | - Sisi Chen
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN USA
| | | | - Eugene Krueger
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN USA
| | - Jeric Hernandez
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN USA
- Enteric Neuroscience Program (ENSP), Mayo Clinic, Rochester, MN USA
| | - Yaroslav Fedyshyn
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN USA
| | - Brooke R. Druliner
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN USA
- Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN USA
| | - David R. Linden
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN USA
- Enteric Neuroscience Program (ENSP), Mayo Clinic, Rochester, MN USA
| | - Arthur Beyder
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN USA
- Enteric Neuroscience Program (ENSP), Mayo Clinic, Rochester, MN USA
- Division of Gastroenterology and Hepatology, Department of Medicine, Mayo Clinic, Rochester, MN USA
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN USA
| |
Collapse
|
4
|
Gwon K, Choi D, de Hoyos-Vega JM, Baskaran H, Gonzalez-Suarez AM, Lee S, Hong HJ, Nguyen KM, Dharmesh E, Sugahara G, Ishida Y, Saito T, Stybayeva G, Revzin A. Function of hepatocyte spheroids in bioactive microcapsules is enhanced by endogenous and exogenous hepatocyte growth factor. Bioact Mater 2023; 28:183-195. [PMID: 37266448 PMCID: PMC10230170 DOI: 10.1016/j.bioactmat.2023.05.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 05/05/2023] [Accepted: 05/09/2023] [Indexed: 06/03/2023] Open
Abstract
The ability to maintain functional hepatocytes has important implications for bioartificial liver development, cell-based therapies, drug screening, and tissue engineering. Several approaches can be used to restore hepatocyte function in vitro, including coating a culture substrate with extracellular matrix (ECM), encapsulating cells within biomimetic gels (Collagen- or Matrigel-based), or co-cultivation with other cells. This paper describes the use of bioactive heparin-based core-shell microcapsules to form and cultivate hepatocyte spheroids. These microcapsules are comprised of an aqueous core that facilitates hepatocyte aggregation into spheroids and a heparin hydrogel shell that binds and releases growth factors. We demonstrate that bioactive microcapsules retain and release endogenous signals thus enhancing the function of encapsulated hepatocytes. We also demonstrate that hepatic function may be further enhanced by loading exogenous hepatocyte growth factor (HGF) into microcapsules and inhibiting transforming growth factor (TGF)-β1 signaling. Overall, bioactive microcapsules described here represent a promising new strategy for the encapsulation and maintenance of primary hepatocytes and will be beneficial for liver tissue engineering, regenerative medicine, and drug testing applications.
Collapse
Affiliation(s)
- Kihak Gwon
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Daheui Choi
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - José M. de Hoyos-Vega
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Harihara Baskaran
- Department of Chemical and Biomolecular Engineering, Case Western Reserve University, Cleveland, OH, USA
| | | | - Seonhwa Lee
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Hye Jin Hong
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Kianna M. Nguyen
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Ether Dharmesh
- Biomedical Engineering, Saint Louis University, St. Louis, MO, USA
| | - Go Sugahara
- University of Southern California, Keck School of Medicine, Department of Medicine, Division of Gastrointestinal and Liver Diseases, Los Angeles, CA, USA
- Research and Development Department, PhoenixBio, Co., Ltd, Kagamiyama, Higashi-Hiroshima, Hiroshima, Japan
| | - Yuji Ishida
- University of Southern California, Keck School of Medicine, Department of Medicine, Division of Gastrointestinal and Liver Diseases, Los Angeles, CA, USA
- Research and Development Department, PhoenixBio, Co., Ltd, Kagamiyama, Higashi-Hiroshima, Hiroshima, Japan
| | - Takeshi Saito
- University of Southern California, Keck School of Medicine, Department of Medicine, Division of Gastrointestinal and Liver Diseases, Los Angeles, CA, USA
- USC Research Center for Liver Diseases, Los Angeles, CA, USA
| | - Gulnaz Stybayeva
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
5
|
Fattahi P, de Hoyos-Vega JM, Choi JH, Duffy CD, Gonzalez-Suarez AM, Ishida Y, Nguyen KM, Gwon K, Peterson QP, Saito T, Stybayeva G, Revzin A. Guiding Hepatic Differentiation of Pluripotent Stem Cells Using 3D Microfluidic Co-Cultures with Human Hepatocytes. Cells 2023; 12:1982. [PMID: 37566061 PMCID: PMC10417547 DOI: 10.3390/cells12151982] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 07/21/2023] [Accepted: 07/26/2023] [Indexed: 08/12/2023] Open
Abstract
Human pluripotent stem cells (hPSCs) are capable of unlimited proliferation and can undergo differentiation to give rise to cells and tissues of the three primary germ layers. While directing lineage selection of hPSCs has been an active area of research, improving the efficiency of differentiation remains an important objective. In this study, we describe a two-compartment microfluidic device for co-cultivation of adult human hepatocytes and stem cells. Both cell types were cultured in a 3D or spheroid format. Adult hepatocytes remained highly functional in the microfluidic device over the course of 4 weeks and served as a source of instructive paracrine cues to drive hepatic differentiation of stem cells cultured in the neighboring compartment. The differentiation of stem cells was more pronounced in microfluidic co-cultures compared to a standard hepatic differentiation protocol. In addition to improving stem cell differentiation outcomes, the microfluidic co-culture system described here may be used for parsing signals and mechanisms controlling hepatic cell fate.
Collapse
Affiliation(s)
- Pouria Fattahi
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA; (P.F.); (J.M.d.H.-V.); (J.H.C.); (C.D.D.); (A.M.G.-S.); (K.M.N.); (K.G.); (Q.P.P.); (G.S.)
- Department of Biomedical Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA
| | - Jose M. de Hoyos-Vega
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA; (P.F.); (J.M.d.H.-V.); (J.H.C.); (C.D.D.); (A.M.G.-S.); (K.M.N.); (K.G.); (Q.P.P.); (G.S.)
| | - Jong Hoon Choi
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA; (P.F.); (J.M.d.H.-V.); (J.H.C.); (C.D.D.); (A.M.G.-S.); (K.M.N.); (K.G.); (Q.P.P.); (G.S.)
| | - Caden D. Duffy
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA; (P.F.); (J.M.d.H.-V.); (J.H.C.); (C.D.D.); (A.M.G.-S.); (K.M.N.); (K.G.); (Q.P.P.); (G.S.)
| | - Alan M. Gonzalez-Suarez
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA; (P.F.); (J.M.d.H.-V.); (J.H.C.); (C.D.D.); (A.M.G.-S.); (K.M.N.); (K.G.); (Q.P.P.); (G.S.)
| | - Yuji Ishida
- Department of Medicine, Division of Gastrointestinal and Liver Diseases, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, USA; (Y.I.); (T.S.)
- Research and Development Unit, PhoenixBio Co., Ltd., Higashi-Hiroshima 739-0046, Japan
| | - Kianna M. Nguyen
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA; (P.F.); (J.M.d.H.-V.); (J.H.C.); (C.D.D.); (A.M.G.-S.); (K.M.N.); (K.G.); (Q.P.P.); (G.S.)
| | - Kihak Gwon
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA; (P.F.); (J.M.d.H.-V.); (J.H.C.); (C.D.D.); (A.M.G.-S.); (K.M.N.); (K.G.); (Q.P.P.); (G.S.)
| | - Quinn P. Peterson
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA; (P.F.); (J.M.d.H.-V.); (J.H.C.); (C.D.D.); (A.M.G.-S.); (K.M.N.); (K.G.); (Q.P.P.); (G.S.)
| | - Takeshi Saito
- Department of Medicine, Division of Gastrointestinal and Liver Diseases, Keck School of Medicine, University of Southern California, Los Angeles, CA 90033, USA; (Y.I.); (T.S.)
| | - Gulnaz Stybayeva
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA; (P.F.); (J.M.d.H.-V.); (J.H.C.); (C.D.D.); (A.M.G.-S.); (K.M.N.); (K.G.); (Q.P.P.); (G.S.)
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA; (P.F.); (J.M.d.H.-V.); (J.H.C.); (C.D.D.); (A.M.G.-S.); (K.M.N.); (K.G.); (Q.P.P.); (G.S.)
| |
Collapse
|
6
|
Lee S, Gonzalez-Suarez AM, Huang X, Calvo-Lozano O, Suvakov S, Lechuga LM, Garovic VD, Stybayeva G, Revzin A. Using Electrochemical Immunoassay in a Novel Microtiter Plate to Detect Surface Markers of Preeclampsia on Urinary Extracellular Vesicles. ACS Sens 2023; 8:207-217. [PMID: 36548998 DOI: 10.1021/acssensors.2c02077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Extracellular vesicles (EVs) are lipid bilayer nanovesicles secreted by cells. EVs contain biological information related to parental cells and provide biomarkers for disease diagnosis. We have previously shown that the levels of podocin and nephrin expression on urinary EVs may be used to diagnose renal injury associated with preeclampsia. This paper describes a nanoparticle-enabled immunoassay integrated with an electrochemical plate for quantifying podocin and nephrin expression in urinary EVs. The strategy entailed capturing EVs on an electrode surface and then labeling EVs with gold nanoparticles that are both functionalized with antibodies for target specificity and impregnated with redox-active metal ions for electrochemical detection. These immunoprobes produced an electrochemical redox signal proportional to the expression level of EV surface markers. Electrochemical immunoassays were carried out in a novel microtiter plate that contained 16 wells with working electrodes connected to onboard counter/reference electrodes via capillary valves. Upon validation with recombinant proteins, a microtiter plate was used for analysis of urinary EVs from healthy and preeclamptic pregnant women. This analysis revealed a higher podocin to nephrin ratio for preeclamptic women compared to healthy controls (4.31 vs 1.69) suggesting that this ratio may be used for disease diagnosis.
Collapse
Affiliation(s)
- Seonhwa Lee
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Alan M Gonzalez-Suarez
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - XuHai Huang
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Olalla Calvo-Lozano
- Nanobiosensors and Bioanalytical Applications Group (NanoB2A), Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, CIBERBBN and BIST, Barcelona 08193, Spain
| | - Sonja Suvakov
- Division of Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Laura M Lechuga
- Nanobiosensors and Bioanalytical Applications Group (NanoB2A), Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, CIBERBBN and BIST, Barcelona 08193, Spain
| | - Vesna D Garovic
- Division of Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Gulnaz Stybayeva
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States.,Sersense Inc., Rochester, Minnesota 55905, United States
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| |
Collapse
|
7
|
Choi D, Gonzalez-Suarez AM, Billadeau DD, Ma WW, Stybayeva G, Revzin A. Patient-Specific Microfluidic Cancer Spheroid Cultures for Testing Cancer Therapies. Methods Mol Biol 2023; 2679:219-231. [PMID: 37300619 DOI: 10.1007/978-1-0716-3271-0_15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The field of oncology increasingly focuses on strategies to predict effectiveness of a given therapy on a patient-by-patient basis. Such precision or personalized oncology has the potential of significantly extending patient survival time. Patient-derived organoids are seen as the main source of patient tumor tissue that may be used for therapy testing in personalized oncology. The gold standard approach for culturing cancer organoids is in standard multi-well plates coated with Matrigel. Despite their effectiveness, these standard organoid cultures have drawbacks, namely, requirement of a large starting cell population and polydispersity of cancer organoid sizes. The latter drawback makes it challenging to monitor and quantify changes in organoid size in response to therapy. Microfluidic devices with integrated arrays of microwells may be used to both decrease the amount of starting cellular material required to form organoids and to standardize organoid size to make therapy assessment easier. Herein, we describe methodology for making microfluidic device as well as for seeding patient-derived cancer cells, culturing organoids, and testing therapies using these devices.
Collapse
Affiliation(s)
- Daheui Choi
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | | | - Daniel D Billadeau
- Department of Immunology, Mayo Clinic College of Medicine and Science, Rochester, MN, USA
| | - Wen Wee Ma
- Division of Oncology, Department of Medicine, Mayo Clinic, Rochester, MN, USA
| | - Gulnaz Stybayeva
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
8
|
Gonzalez-Suarez AM, Long A, Huang X, Revzin A. A Compact Control System to Enable Automated Operation of Microfluidic Bioanalytical Assays. Biosensors (Basel) 2022; 12:1160. [PMID: 36551127 PMCID: PMC9775492 DOI: 10.3390/bios12121160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 10/31/2022] [Accepted: 11/01/2022] [Indexed: 06/17/2023]
Abstract
We describe a control system for operating valve-enabled microfluidic devices and leverage this control system to carry out a complex workflow of plasma separation from 8 μL of whole blood followed by on-chip mixing of plasma with assay reagents for biomarker detection. The control system incorporates pumps, digital pressure sensors, a microcontroller, solenoid valves and off-the-shelf components to deliver high and low air pressure in the desired temporal sequence to meter fluid flow and actuate microvalves. Importantly, our control system is portable, which is suitable for operating the microvalve-enabled microfluidic devices in the point-of-care setting.
Collapse
Affiliation(s)
| | - Alexander Long
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA
- Department of Biology, St. Olaf College, Northfield, MN 55057, USA
| | - XuHai Huang
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905, USA
| |
Collapse
|
9
|
Zhang X, Pearsall VM, Carver CM, Atkinson EJ, Clarkson BDS, Grund EM, Baez-Faria M, Pavelko KD, Kachergus JM, White TA, Johnson RK, Malo CS, Gonzalez-Suarez AM, Ayasoufi K, Johnson KO, Tritz ZP, Fain CE, Khadka RH, Ogrodnik M, Jurk D, Zhu Y, Tchkonia T, Revzin A, Kirkland JL, Johnson AJ, Howe CL, Thompson EA, LeBrasseur NK, Schafer MJ. Rejuvenation of the aged brain immune cell landscape in mice through p16-positive senescent cell clearance. Nat Commun 2022; 13:5671. [PMID: 36167854 PMCID: PMC9515187 DOI: 10.1038/s41467-022-33226-8] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Accepted: 09/06/2022] [Indexed: 11/10/2022] Open
Abstract
Cellular senescence is a plausible mediator of inflammation-related tissue dysfunction. In the aged brain, senescent cell identities and the mechanisms by which they exert adverse influence are unclear. Here we used high-dimensional molecular profiling, coupled with mechanistic experiments, to study the properties of senescent cells in the aged mouse brain. We show that senescence and inflammatory expression profiles increase with age and are brain region- and sex-specific. p16-positive myeloid cells exhibiting senescent and disease-associated activation signatures, including upregulation of chemoattractant factors, accumulate in the aged mouse brain. Senescent brain myeloid cells promote peripheral immune cell chemotaxis in vitro. Activated resident and infiltrating immune cells increase in the aged brain and are partially restored to youthful levels through p16-positive senescent cell clearance in female p16-InkAttac mice, which is associated with preservation of cognitive function. Our study reveals dynamic remodeling of the brain immune cell landscape in aging and suggests senescent cell targeting as a strategy to counter inflammatory changes and cognitive decline.
Collapse
Affiliation(s)
- Xu Zhang
- Robert and Arlene Kogod Center on Aging, Mayo Clinic, Rochester, MN, USA
- Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, MN, USA
| | | | - Chase M Carver
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Elizabeth J Atkinson
- Division of Clinical Trials and Biostatistics, Department of Quantitative Health Sciences, Mayo Clinic, Rochester, MN, USA
| | - Benjamin D S Clarkson
- Department of Neurology, Mayo Clinic, Rochester, MN, USA
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA
| | - Ethan M Grund
- Mayo Graduate School and Medical Scientist Training Program, Mayo Clinic, Rochester, MN, USA
| | - Michelle Baez-Faria
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, USA
| | | | - Jennifer M Kachergus
- Department of Cancer Biology, Mayo Clinic Comprehensive Cancer Center, Mayo Clinic, Jacksonville, FL, USA
| | - Thomas A White
- Robert and Arlene Kogod Center on Aging, Mayo Clinic, Rochester, MN, USA
| | | | | | | | | | - Kurt O Johnson
- Robert and Arlene Kogod Center on Aging, Mayo Clinic, Rochester, MN, USA
| | | | - Cori E Fain
- Department of Immunology, Mayo Clinic, Rochester, MN, USA
| | - Roman H Khadka
- Department of Immunology, Mayo Clinic, Rochester, MN, USA
| | - Mikolaj Ogrodnik
- Robert and Arlene Kogod Center on Aging, Mayo Clinic, Rochester, MN, USA
- Ludwig Boltzmann Research Group Senescence and Healing of Wounds, Vienna, Austria
| | - Diana Jurk
- Robert and Arlene Kogod Center on Aging, Mayo Clinic, Rochester, MN, USA
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
- Department of Neurology, Mayo Clinic, Rochester, MN, USA
| | - Yi Zhu
- Robert and Arlene Kogod Center on Aging, Mayo Clinic, Rochester, MN, USA
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Tamara Tchkonia
- Robert and Arlene Kogod Center on Aging, Mayo Clinic, Rochester, MN, USA
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - James L Kirkland
- Robert and Arlene Kogod Center on Aging, Mayo Clinic, Rochester, MN, USA
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
- Department of General Internal Medicine, Mayo Clinic, Rochester, MN, USA
| | | | - Charles L Howe
- Department of Neurology, Mayo Clinic, Rochester, MN, USA
- Center for Multiple Sclerosis and Autoimmune Neurology, Mayo Clinic, Rochester, MN, USA
- Division of Experimental Neurology, Mayo Clinic, Rochester, MN, USA
| | - E Aubrey Thompson
- Department of Cancer Biology, Mayo Clinic Comprehensive Cancer Center, Mayo Clinic, Jacksonville, FL, USA
| | - Nathan K LeBrasseur
- Robert and Arlene Kogod Center on Aging, Mayo Clinic, Rochester, MN, USA
- Department of Physical Medicine and Rehabilitation, Mayo Clinic, Rochester, MN, USA
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Marissa J Schafer
- Robert and Arlene Kogod Center on Aging, Mayo Clinic, Rochester, MN, USA.
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
- Department of Neurology, Mayo Clinic, Rochester, MN, USA.
| |
Collapse
|
10
|
Choi D, Gwon K, Hong HJ, Baskaran H, Calvo-Lozano O, Gonzalez-Suarez AM, Park K, de Hoyos-Vega JM, Lechuga LM, Hong J, Stybayeva G, Revzin A. Coating Bioactive Microcapsules with Tannic Acid Enhances the Phenotype of the Encapsulated Pluripotent Stem Cells. ACS Appl Mater Interfaces 2022; 14:10.1021/acsami.2c06783. [PMID: 35658394 PMCID: PMC10314364 DOI: 10.1021/acsami.2c06783] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Human pluripotent stem cells (hPSCs) may be differentiated into any adult cell type and therefore hold incredible promise for cell therapeutics and disease modeling. There is increasing interest in three-dimensional (3D) hPSC culture because of improved differentiation outcomes and potential for scale up. Our team has recently described bioactive heparin (Hep)-containing core-shell microcapsules that promote rapid aggregation of stem cells into spheroids and may also be loaded with growth factors for the local and sustained delivery to the encapsulated cells. In this study, we explored the possibility of further modulating bioactivity of microcapsules through the use of an ultrathin coating composed of tannic acid (TA). Deposition of the TA film onto model substrates functionalized with Hep and poly(ethylene glycol) was characterized by ellipsometry and atomic force microscopy. Furthermore, the presence of the TA coating was observed to increase the amount of basic fibroblast growth factor (bFGF) incorporation by up to twofold and to extend its release from 5 to 7 days. Most significantly, TA-microcapsules loaded with bFGF induced higher levels of pluripotency expression compared to uncoated microcapsules containing bFGF. Engineered microcapsules described here represent a new stem cell culture approach that enables 3D cultivation and relies on local delivery of inductive cues.
Collapse
Affiliation(s)
- Daheui Choi
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Kihak Gwon
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Hye Jin Hong
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Harihara Baskaran
- Department of Chemical and Biomolecular Engineering, Case Western Reserve University, Cleveland, Ohio 44106, United States
| | - Olalla Calvo-Lozano
- Nanobiosensors and Bioanalytical Applications Group (NanoB2A), Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, CIBERBBN and BIST, Barcelona 08193, Spain
| | - Alan M Gonzalez-Suarez
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Kyungtae Park
- Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Jose M de Hoyos-Vega
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Laura M Lechuga
- Nanobiosensors and Bioanalytical Applications Group (NanoB2A), Catalan Institute of Nanoscience and Nanotechnology (ICN2), CSIC, CIBERBBN and BIST, Barcelona 08193, Spain
| | - Jinkee Hong
- Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul 03722, Republic of Korea
| | - Gulnaz Stybayeva
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| |
Collapse
|
11
|
Gonzalez-Suarez AM, Stybayeva G, Carey WA, Revzin A. Automated Microfluidic System with Active Mixing Enables Rapid Analysis of Biomarkers in 5 μL of Whole Blood. Anal Chem 2022; 94:9706-9714. [PMID: 35604796 DOI: 10.1021/acs.analchem.2c01139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
We developed a microfluidic device for the rapid analysis of biomarkers in small volumes of whole blood. This device includes an onboard plasma separation module connected to a downstream bioanalysis module in which plasma mixes with reagents and the results of a colorimetric assay are recorded. Actuation of onboard microvalves within a bioanalysis module creates active mixing conditions that allowed us to achieve solution homogeneity within 5 min. To demonstrate utility, we carried out glucose detection in our device. With 5 μL of whole blood as an input, our microfluidic device enabled a time-to-answer of 10 min with a limit of detection of 0.21 ± 0.04 mM for glucose. This device has immediate applications for rapid and sensitive monitoring of hypoglycemia at the point of care (POC). Furthermore, our automated microfluidic device represents a platform technology that may be used to detect other biomarkers in whole blood.
Collapse
Affiliation(s)
- Alan M Gonzalez-Suarez
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Gulnaz Stybayeva
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States.,Sersense Inc., Rochester, Minnesota 55905, United States
| | - William A Carey
- Department of Pediatric and Adolescent Medicine, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| |
Collapse
|
12
|
Gwon K, Hong HJ, Gonzalez-Suarez AM, Slama MQ, Choi D, Hong J, Baskaran H, Stybayeva G, Peterson QP, Revzin A. Bioactive hydrogel microcapsules for guiding stem cell fate decisions by release and reloading of growth factors. Bioact Mater 2021; 15:1-14. [PMID: 35386345 PMCID: PMC8941170 DOI: 10.1016/j.bioactmat.2021.12.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Revised: 11/22/2021] [Accepted: 12/12/2021] [Indexed: 12/21/2022] Open
Abstract
Human pluripotent stem cells (hPSC) hold considerable promise as a source of adult cells for treatment of diseases ranging from diabetes to liver failure. Some of the challenges that limit the clinical/translational impact of hPSCs are high cost and difficulty in scaling-up of existing differentiation protocols. In this paper, we sought to address these challenges through the development of bioactive microcapsules. A co-axial flow focusing microfluidic device was used to encapsulate hPSCs in microcapsules comprised of an aqueous core and a hydrogel shell. Importantly, the shell contained heparin moieties for growth factor (GF) binding and release. The aqueous core enabled rapid aggregation of hPSCs into 3D spheroids while the bioactive hydrogel shell was used to load inductive cues driving pluripotency maintenance and endodermal differentiation. Specifically, we demonstrated that one-time, 1 h long loading of pluripotency signals, fibroblast growth factor (FGF)-2 and transforming growth factor (TGF)-β1, into bioactive microcapsules was sufficient to induce and maintain pluripotency of hPSCs over the course of 5 days at levels similar to or better than a standard protocol with soluble GFs. Furthermore, stem cell-carrying microcapsules that previously contained pluripotency signals could be reloaded with an endodermal cue, Nodal, resulting in higher levels of endodermal markers compared to stem cells differentiated in a standard protocol. Overall, bioactive heparin-containing core-shell microcapsules decreased GF usage five-fold while improving stem cell phenotype and are well suited for 3D cultivation of hPSCs. Heparin-containing microcapsules enable sustained release of inductive cues (growth factors) over the course of seven to nine days. Heparin-growth factor binding is reversible which means that different growth factors may be loaded in a sequential manner. Loading inductive cues into microcapsules results in better differentiation of pluripotent stem cells. Loading inductive cues into microcapsules allows to decrease the usage of growth factors by several fold.
Collapse
Affiliation(s)
- Kihak Gwon
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
| | - Hye Jin Hong
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
| | | | - Michael Q. Slama
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
| | - Daheui Choi
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
- Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul, 03722, Republic of Korea
| | - Jinkee Hong
- Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul, 03722, Republic of Korea
| | - Harihara Baskaran
- Department of Chemical and Biomolecular Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Gulnaz Stybayeva
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
| | - Quinn P. Peterson
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
- Corresponding author.
| |
Collapse
|
13
|
Gwon K, Hong HJ, Gonzalez-Suarez AM, Stybayeva G, Revzin A. Microfluidic Fabrication of Core-Shell Microcapsules carrying Human Pluripotent Stem Cell Spheroids. J Vis Exp 2021. [PMID: 34723935 DOI: 10.3791/62944] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022] Open
Abstract
Three-dimensional (3D) or spheroid cultures of human pluripotent stem cells (hPSCs) offer the benefits of improved differentiation outcomes and scalability. In this paper, we describe a strategy for the robust and reproducible formation of hPSC spheroids where a co-axial flow focusing device is utilized to entrap hPSCs inside core-shell microcapsules. The core solution contained single cell suspension of hPSCs and was made viscous by the incorporation of high molecular weight poly(ethylene glycol) (PEG) and density gradient media. The shell stream comprised of PEG-4 arm-maleimide or PEG-4-Mal and flowed alongside the core stream toward two consecutive oil junctions. Droplet formation occurred at the first oil junction with shell solution wrapping itself around the core. Chemical crosslinking of the shell occurred at the second oil junction by introducing a di-thiol crosslinker (1,4-dithiothreitol or DTT) to these droplets. The crosslinker reacts with maleimide functional groups via click chemistry, resulting in the formation of a hydrogel shell around the microcapsules. Our encapsulation technology produced 400 µm diameter capsules at a rate of 10 capsules per second. The resultant capsules had a hydrogel shell and an aqueous core that allowed single cells to rapidly assemble into aggregates and form spheroids. The process of encapsulation did not adversely affect the viability of hPSCs, with >95% viability observed 3 days post-encapsulation. For comparison, hPSCs encapsulated in solid gel microparticles (without an aqueous core) did not form spheroids and had <50% viability 3 days after encapsulation. Spheroid formation of hPSCs inside core-shell microcapsules occurred within 48 h after encapsulation, with the spheroid diameter being a function of cell inoculation density. Overall, the microfluidic encapsulation technology described in this protocol was well-suited for hPSCs encapsulation and spheroid formation.
Collapse
Affiliation(s)
- Kihak Gwon
- Department of Physiology and Biomedical Engineering, Mayo Clinic
| | - Hye Jin Hong
- Department of Physiology and Biomedical Engineering, Mayo Clinic
| | | | - Gulnaz Stybayeva
- Department of Physiology and Biomedical Engineering, Mayo Clinic
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic;
| |
Collapse
|
14
|
Fattahi P, Rahimian A, Slama MQ, Gwon K, Gonzalez-Suarez AM, Wolf J, Baskaran H, Duffy CD, Stybayeva G, Peterson QP, Revzin A. Core-shell hydrogel microcapsules enable formation of human pluripotent stem cell spheroids and their cultivation in a stirred bioreactor. Sci Rep 2021; 11:7177. [PMID: 33785778 PMCID: PMC8010084 DOI: 10.1038/s41598-021-85786-2] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Accepted: 03/02/2021] [Indexed: 12/22/2022] Open
Abstract
Cellular therapies based on human pluripotent stem cells (hPSCs) offer considerable promise for treating numerous diseases including diabetes and end stage liver failure. Stem cell spheroids may be cultured in stirred bioreactors to scale up cell production to cell numbers relevant for use in humans. Despite significant progress in bioreactor culture of stem cells, areas for improvement remain. In this study, we demonstrate that microfluidic encapsulation of hPSCs and formation of spheroids. A co-axial droplet microfluidic device was used to fabricate 400 μm diameter capsules with a poly(ethylene glycol) hydrogel shell and an aqueous core. Spheroid formation was demonstrated for three hPSC lines to highlight broad utility of this encapsulation technology. In-capsule differentiation of stem cell spheroids into pancreatic β-cells in suspension culture was also demonstrated.
Collapse
Affiliation(s)
- Pouria Fattahi
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
| | - Ali Rahimian
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
| | - Michael Q Slama
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
| | - Kihak Gwon
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
| | - Alan M Gonzalez-Suarez
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
| | - Jadon Wolf
- Department of Chemical and Biomolecular Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Harihara Baskaran
- Department of Chemical and Biomolecular Engineering, Case Western Reserve University, Cleveland, OH, 44106, USA
| | - Caden D Duffy
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
| | - Gulnaz Stybayeva
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
| | - Quinn P Peterson
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, 55902, USA.
| |
Collapse
|
15
|
Cruz-Zárate D, López-Ortega O, Girón-Pérez DA, Gonzalez-Suarez AM, García-Cordero JL, Schnoor M, Santos-Argumedo L. Myo1g is required for efficient adhesion and migration of activated B lymphocytes to inguinal lymph nodes. Sci Rep 2021; 11:7197. [PMID: 33785780 PMCID: PMC8009870 DOI: 10.1038/s41598-021-85477-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Accepted: 02/18/2021] [Indexed: 11/15/2022] Open
Abstract
Cell migration is a dynamic process that involves adhesion molecules and the deformation of the moving cell that depends on cytoskeletal remodeling and actin-modulating proteins such as myosins. In this work, we analyzed the role of the class I Myosin-1 g (Myo1g) in migratory processes of LPS + IL-4 activated B lymphocytes in vivo and in vitro. In vivo, the absence of Myo1g reduced homing of activated B lymphocytes into the inguinal lymph node. Using microchannel chambers and morphology analysis, we found that the lack of Myo1g caused adhesion and chemotaxis defects. Additionally, deficiency in Myo1g causes flaws in adopting a migratory morphology. Our results highlight the importance of Myo1g during B cell migration.
Collapse
Affiliation(s)
- D Cruz-Zárate
- Departamento de Biomedicina Molecular, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Av. Instituto Politécnico Nacional 2508, San Pedro Zacatenco, 07360, Mexico City, Mexico
- Departmento and Posgrado en Inmunologia, Escuela Nacional de Ciencias Biologicas del Instituto Politécnico Nacional (ENCB-IPN), Mexico City, Mexico
| | - O López-Ortega
- Departamento de Biomedicina Molecular, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Av. Instituto Politécnico Nacional 2508, San Pedro Zacatenco, 07360, Mexico City, Mexico
| | - D A Girón-Pérez
- Departamento de Biomedicina Molecular, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Av. Instituto Politécnico Nacional 2508, San Pedro Zacatenco, 07360, Mexico City, Mexico
| | - A M Gonzalez-Suarez
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Monterrey, NL, Mexico
| | - J L García-Cordero
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Monterrey, NL, Mexico
| | - M Schnoor
- Departamento de Biomedicina Molecular, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Av. Instituto Politécnico Nacional 2508, San Pedro Zacatenco, 07360, Mexico City, Mexico
| | - L Santos-Argumedo
- Departamento de Biomedicina Molecular, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional (CINVESTAV-IPN), Av. Instituto Politécnico Nacional 2508, San Pedro Zacatenco, 07360, Mexico City, Mexico.
| |
Collapse
|
16
|
Dadgar N, Gonzalez-Suarez AM, Fattahi P, Hou X, Weroha JS, Gaspar-Maia A, Stybayeva G, Revzin A. A microfluidic platform for cultivating ovarian cancer spheroids and testing their responses to chemotherapies. Microsyst Nanoeng 2020; 6:93. [PMID: 34567703 PMCID: PMC8433468 DOI: 10.1038/s41378-020-00201-6] [Citation(s) in RCA: 44] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 07/29/2020] [Accepted: 08/02/2020] [Indexed: 05/14/2023]
Abstract
There is increasing interest in utilizing in vitro cultures as patient avatars to develop personalized treatment for cancer. Typical cultures utilize Matrigel-coated plates and media to promote the proliferation of cancer cells as spheroids or tumor explants. However, standard culture conditions operate in large volumes and require a high concentration of cancer cells to initiate this process. Other limitations include variability in the ability to successfully establish a stable line and inconsistency in the dimensions of these microcancers for in vivo drug response measurements. This paper explored the utility of microfluidics in the cultivation of cancer cell spheroids. Six patient-derived xenograft (PDX) tumors of high-grade serous ovarian cancer were used as the source material to demonstrate that viability and epithelial marker expression in the microfluidic cultures was superior to that of Matrigel or large volume 3D cultures. To further demonstrate the potential for miniaturization and multiplexing, we fabricated multichamber microfluidic devices with integrated microvalves to enable serial seeding of several chambers followed by parallel testing of several drug concentrations. These valve-enabled microfluidic devices permitted the formation of spheroids and testing of seven drug concentrations with as few as 100,000 cancer cells per device. Overall, we demonstrate the feasibility of maintaining difficul-to-culture primary cancer cells and testing drugs in a microfluidic device. This microfluidic platform may be ideal for drug testing and personalized therapy when tumor material is limited, such as following the acquisition of biopsy specimens obtained by fine-needle aspiration.
Collapse
Affiliation(s)
- Neda Dadgar
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905 USA
| | | | - Pouria Fattahi
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905 USA
| | - Xiaonan Hou
- Department of Medical Oncology, Mayo Clinic, Rochester, MN 55905 USA
| | - John S. Weroha
- Department of Medical Oncology, Mayo Clinic, Rochester, MN 55905 USA
| | - Alexandre Gaspar-Maia
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905 USA
| | - Gulnaz Stybayeva
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905 USA
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN 55905 USA
| |
Collapse
|
17
|
Hwang SH, Gonzalez-Suarez AM, Stybayeva G, Revzin A. Prospects and Opportunities for Microsystems and Microfluidic Devices in the Field of Otorhinolaryngology. Clin Exp Otorhinolaryngol 2020; 14:29-42. [PMID: 32772034 PMCID: PMC7904428 DOI: 10.21053/ceo.2020.00626] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Accepted: 05/27/2020] [Indexed: 12/21/2022] Open
Abstract
Microfluidic systems can be used to control picoliter to microliter volumes in ways not possible with other methods of fluid handling. In recent years, the field of microfluidics has grown rapidly, with microfluidic devices offering possibilities to impact biology and medicine. Microfluidic devices populated with human cells have the potential to mimic the physiological functions of tissues and organs in a three-dimensional microenvironment and enable the study of mechanisms of human diseases, drug discovery and the practice of personalized medicine. In the field of otorhinolaryngology, various types of microfluidic systems have already been introduced to study organ physiology, diagnose diseases, and evaluate therapeutic efficacy. Therefore, microfluidic technologies can be implemented at all levels of otorhinolaryngology. This review is intended to promote understanding of microfluidic properties and introduce the recent literature on application of microfluidic-related devices in the field of otorhinolaryngology.
Collapse
Affiliation(s)
- Se Hwan Hwang
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.,Department of Otolaryngology-Head and Neck Surgery, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Bucheon, Korea
| | | | - Gulnaz Stybayeva
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | - Alexander Revzin
- Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
18
|
de Hoyos-Vega JM, Gonzalez-Suarez AM, Garcia-Cordero JL. A versatile microfluidic device for multiple ex vivo/in vitro tissue assays unrestrained from tissue topography. Microsyst Nanoeng 2020; 6:40. [PMID: 34567653 PMCID: PMC8433291 DOI: 10.1038/s41378-020-0156-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 03/04/2020] [Accepted: 03/12/2020] [Indexed: 05/28/2023]
Abstract
Precision-cut tissue slices are an important in vitro system to study organ function because they preserve most of the native cellular microenvironments of organs, including complex intercellular connections. However, during sample manipulation or slicing, some of the natural surface topology and structure of these tissues is lost or damaged. Here, we introduce a microfluidic platform to perform multiple assays on the surface of a tissue section, unhindered by surface topography. The device consists of a valve on one side and eight open microchannels located on the opposite side, with the tissue section sandwiched between these two structures. When the valve is actuated, eight independent microfluidic channels are formed over a tissue section. This strategy prevents cross-contamination when performing assays and enables parallelization. Using irregular tissues such as an aorta, we conducted multiple in vitro and ex vivo assays on tissue sections, including short-term culturing, a drug toxicity assay, a fluorescence immunohistochemistry staining assay, and an immune cell assay, in which we observed the interaction of neutrophils with lipopolysaccharide (LPS)-stimulated endothelium. Our microfluidic platform can be employed in other disciplines, such as tissue physiology and pathophysiology, morphogenesis, drug toxicity and efficiency, metabolism studies, and diagnostics, enabling the conduction of several assays with a single biopsy sample.
Collapse
Affiliation(s)
- Jose M. de Hoyos-Vega
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del IPN, Via del conocimiento 201, Parque PIIT, Apodaca, NL 66628 Mexico
| | - Alan M. Gonzalez-Suarez
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del IPN, Via del conocimiento 201, Parque PIIT, Apodaca, NL 66628 Mexico
| | - Jose L. Garcia-Cordero
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del IPN, Via del conocimiento 201, Parque PIIT, Apodaca, NL 66628 Mexico
| |
Collapse
|
19
|
Calixto S, Piazza V, Gonzalez-Suarez AM, Garcia-Cordero JL, Bruce NC, Rosete-Aguilar M, Garnica G. Liquid refractive index measured through a refractometer based on diffraction gratings. Opt Express 2019; 27:34705-34720. [PMID: 31878655 DOI: 10.1364/oe.27.034705] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Accepted: 10/22/2019] [Indexed: 06/10/2023]
Abstract
We developed two versions of refractometers to measure the refractive index of liquids. One refractometer comprises a glass cell with a surface relief grating on the inner face of one of its walls, while the other one is a microfluidic channel in the form of serpentine that behaves as a grating. Measurements of the liquid refractive index were performed by sensing the first order intensity. Several liquids have been used including an organic one. Calibration plots are shown.
Collapse
|
20
|
Tristan-Landin SB, Gonzalez-Suarez AM, Jimenez-Valdes RJ, Garcia-Cordero JL. Facile assembly of an affordable miniature multicolor fluorescence microscope made of 3D-printed parts enables detection of single cells. PLoS One 2019; 14:e0215114. [PMID: 31600202 PMCID: PMC6786622 DOI: 10.1371/journal.pone.0215114] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Accepted: 09/20/2019] [Indexed: 11/18/2022] Open
Abstract
Fluorescence microscopy is one of the workhorses of biomedical research and laboratory diagnosis; however, their cost, size, maintenance, and fragility has prevented their adoption in developing countries or low-resource settings. Although significant advances have decreased their size, cost and accessibility, their designs and assembly remain rather complex. Here, inspired on the simple mechanism from a nut and a bolt, we report the construction of a portable fluorescence microscope that operates in bright-field mode and in three fluorescence channels: UV, green, and red. It is assembled in under 10 min from only six 3D printed parts, basic electronic components, a microcomputer (Raspberry Pi) and a camera, all of which can be readily purchased in most locations or online for US $122. The microcomputer was programmed in Python language to capture time-lapse images and videos. Resolution and illumination conditions of the microscope were characterized, and its performance was compared with a high-end fluorescence microscope in bright-field and fluorescence mode. We demonstrate that our miniature microscope can resolve and track single cells in both modes. The instructions on how to assemble the microscope are shown in a video, and the software to control it and the design files of the 3D-printed parts are freely available online. Our portable microscope is ideal in applications where space is at a premium, such as lab-on-a-chips or space missions, and can find applications in basic and clinical research, diagnostics, telemedicine and in educational settings.
Collapse
Affiliation(s)
- Samuel B. Tristan-Landin
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del IPN, Parque PIIT, Apodaca, Nuevo León, Mexico
| | - Alan M. Gonzalez-Suarez
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del IPN, Parque PIIT, Apodaca, Nuevo León, Mexico
| | - Rocio J. Jimenez-Valdes
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del IPN, Parque PIIT, Apodaca, Nuevo León, Mexico
| | - Jose L. Garcia-Cordero
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del IPN, Parque PIIT, Apodaca, Nuevo León, Mexico
- * E-mail:
| |
Collapse
|
21
|
Gonzalez-Suarez AM, Peña-del Castillo JG, Hernández-Cruz A, Garcia-Cordero JL. Dynamic Generation of Concentration- and Temporal-Dependent Chemical Signals in an Integrated Microfluidic Device for Single-Cell Analysis. Anal Chem 2018; 90:8331-8336. [DOI: 10.1021/acs.analchem.8b02442] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Alan M. Gonzalez-Suarez
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, Parque PIIT, Apodaca, Nuevo León, 66628, México
| | - Johanna G. Peña-del Castillo
- Departamento de Neurociencia Cognitiva y Laboratorio Nacional de Canalopatías, Instituto de Fisiología Celular, Circuito de la Investigación Científica s/n Ciudad Universitaria, Universidad Nacional Autónoma de México, Ciudad de México 04510, México
| | - Arturo Hernández-Cruz
- Departamento de Neurociencia Cognitiva y Laboratorio Nacional de Canalopatías, Instituto de Fisiología Celular, Circuito de la Investigación Científica s/n Ciudad Universitaria, Universidad Nacional Autónoma de México, Ciudad de México 04510, México
| | - Jose L. Garcia-Cordero
- Unidad Monterrey, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, Parque PIIT, Apodaca, Nuevo León, 66628, México
| |
Collapse
|
22
|
Urrios A, Parra-Cabrera C, Bhattacharjee N, Gonzalez-Suarez AM, Rigat-Brugarolas LG, Nallapatti U, Samitier J, DeForest CA, Posas F, Garcia-Cordero JL, Folch A. 3D-printing of transparent bio-microfluidic devices in PEG-DA. Lab Chip 2016; 16:2287-94. [PMID: 27217203 PMCID: PMC4930360 DOI: 10.1039/c6lc00153j] [Citation(s) in RCA: 144] [Impact Index Per Article: 18.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
The vast majority of microfluidic systems are molded in poly(dimethylsiloxane) (PDMS) by soft lithography due to the favorable properties of PDMS: biocompatible, elastomeric, transparent, gas-permeable, inexpensive, and copyright-free. However, PDMS molding involves tedious manual labor, which makes PDMS devices prone to assembly failures and difficult to disseminate to research and clinical settings. Furthermore, the fabrication procedures limit the 3D complexity of the devices to layered designs. Stereolithography (SL), a form of 3D-printing, has recently attracted attention as a way to customize the fabrication of biomedical devices due to its automated, assembly-free 3D fabrication, rapidly decreasing costs, and fast-improving resolution and throughput. However, existing SL resins are not biocompatible and patterning transparent resins at high resolution remains difficult. Here we report procedures for the preparation and patterning of a transparent resin based on low-MW poly(ethylene glycol) diacrylate (MW 250) (PEG-DA-250). The 3D-printed devices are highly transparent and cells can be cultured on PEG-DA-250 prints for several days. This biocompatible SL resin and printing process solves some of the main drawbacks of 3D-printed microfluidic devices: biocompatibility and transparency. In addition, it should also enable the production of non-microfluidic biomedical devices.
Collapse
Affiliation(s)
- Arturo Urrios
- Cell Signaling Research Group, Departament de Ciències Experimentals i de la Salut, Universitat Pompeu Fabra (UPF), E-08003 Barcelona, Spain
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|