1
|
Evaluation of surface roughness, wettability and adhesion of multispecies biofilm on 3D-printed resins for the base and teeth of complete dentures. J Appl Oral Sci 2024; 32:e20230326. [PMID: 38656049 DOI: 10.1590/1678-7757-2023-0326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Accepted: 02/22/2024] [Indexed: 04/26/2024] Open
Abstract
OBJECTIVE This study evaluated the surface roughness, wettability and adhesion of multispecies biofilms (Candida albicans, Staphylococcus aureus and Streptococcus mutans) on 3D-printed resins for complete denture bases and teeth compared to conventional resins (heat-polymerized acrylic resin; artificial pre-fabricated teeth). METHODOLOGY Circular specimens (n=39; 6.0 mm Ø × 2.0 mm) of each group were subjected to roughness (n=30), wettability (n=30) and biofilm adhesion (n=9) tests. Three roughness measurements were taken by laser confocal microscopy and a mean value was calculated. Wettability was evaluated by the contact angle of sessile drop method, considering the mean of the three evaluations per specimen. In parallel, microorganism adhesion to resin surfaces was evaluated using a multispecies biofilm model. Microbial load was evaluated by determining the number of Colony Forming Units (CFU/mL) and by scanning electron microscopy (SEM). Data were subjected to the Wald test in a generalized linear model with multiple comparisons and Bonferroni adjustment, as well as two-way ANOVA (α=5%). RESULTS The roughness of the conventional base resin (0.01±0.04) was lower than that of the conventional tooth (0.14±0.04) (p=0.023) and 3D-printed base (0.18±0.08) (p<0.001). For wettability, conventional resin (84.20±5.57) showed a higher contact angle than the 3D-printed resin (60.58±6.18) (p<0.001). Higher microbial loads of S. mutans (p=0.023) and S. aureus (p=0.010) were observed on the surface of the conventional resin (S. mutans: 5.48±1.55; S. aureus: 7.01±0.57) compared to the 3D-printed resin (S. mutans: 4.11±1.96; S. aureus: 6.42±0.78). The adhesion of C. albicans was not affected by surface characteristics. The conventional base resin showed less roughness than the conventional dental resin and the printed base resin. CONCLUSION The 3D-printed resins for base and tooth showed less hydrophobicity and less adhesion of S. mutans and S. aureus than conventional resins.
Collapse
|
2
|
Cafeteria Diet Can Affect Bone Microarchitecture in Sedentary and Trained Male Rats. J Clin Densitom 2024; 27:101467. [PMID: 38306807 DOI: 10.1016/j.jocd.2024.101467] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 12/31/2023] [Accepted: 01/18/2024] [Indexed: 02/04/2024]
Abstract
INTRODUCTION Poor eating habits and a sedentary lifestyle can impair health. Regular physical activity improves the quality of life and is essential for bone health. Therefore, the present study aimed to evaluate the effects of the cafeteria diet on bone quality of sedentary and exercised rats. METHODS Sixty young male Wistar rats were divided into six groups (n=10) according to diet composition and activity level, being: SD+CON, standard diet and control; SD+SED, standard diet and sedentary; SD+EX, standard diet and exercised; CD+CON, cafeteria diet and control; CD+SED, cafeteria diet and sedentary; CD+EX, cafeteria diet and exercised. The exercise protocol consisted of 10 ladder-climbing sessions/day, 5 days/week, and the sedentary rats were maintained in individual cages with limited mobility. Body mass and food intake were evaluated weekly. After 10 weeks, the animals were euthanized, and white adipose tissue was collected. The bone structure was evaluated by densitometry, mechanical tests, histomorphometric, and micro-computed tomography analyses. RESULTS The cafeteria diet increased adipose tissue (p<0.001), decreased bone mineral density (p=0.004), and impaired biomechanical properties (p<0.05) and histomorphometry parameters (p=0.044). The sedentarism decreased bone mineral density (p<0.001) and biomechanical properties (p<0.05), and the exercise did not improve bone properties. CONCLUSION In this experimental model, it was concluded that the cafeteria diet and a sedentary lifestyle negatively affect bone, and ladder-climbing exercise could not prevent the effects of the unhealthy diet.
Collapse
|
3
|
An in vitro study using confocal laser scanning microscopy to evaluate the marginal misfits of different implant-supported frameworks. J Prosthodont 2024. [PMID: 38305664 DOI: 10.1111/jopr.13826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 01/09/2024] [Indexed: 02/03/2024] Open
Abstract
PURPOSE This study aimed to develop and evaluate a simple, non-destructive method for assessing the misfit and passivity of implant-retained prostheses frameworks. MATERIALS AND METHODS To simulate the rehabilitation of a mandible posterior partially edentulous area using 3-unit screw-retained frameworks supported by two implants were fabricated and divided into the following five groups (n = 10 in each group): OP = one-piece framework cast in Co-Cr with the conventional method (control-group); Co-Cr frameworks sectioned and welded by laser (=LAS) or tungsten inert gas (=TIG); Co-Cr CAD-CAM = milled Co-Cr framework; Zir CAD-CAM = milled zirconia framework. The horizontal |X| and vertical |Y| misfits were measured using confocal laser scanning microscopy with one or both screws tightened. Data were analyzed by a two-way ANOVA with repeated measures and Bonferroni correction (α = 0.05). RESULTS The greatest |X| misfit was observed in the OP group with both screws tightened (290 µm) and one screw tightened (388 and 340 µm). The conventional casting groups sectioned and welded by laser or TIG had lower mean values (235.35 µm, both screws tightened; and 275 µm, one screw tightened) than the OP framework. However, these values still exceeded those of the milled Co-Cr and zirconia frameworks (190 and 216 µm with both screws tightened). Across all reading conditions, every framework subjected to testing consistently maintained vertical |Y| misfit levels below the threshold of 53 µm; however, the milled frameworks exhibited higher vertical misfits than the frameworks obtained by the conventional cast method. CONCLUSIONS The frameworks, whether cast and sectioned with laser welding or milled from Co-Cr, exhibit improved marginal misfit and enhanced passive fit when compared to other fabrication methods. Additionally, the use of confocal laser scanning microscopy is highly effective for passivity and misfit analysis.
Collapse
|
4
|
Psychometric properties analysis of helping relationships skills inventory for Portuguese nurses and doctors. Heliyon 2024; 10:e23713. [PMID: 38187244 PMCID: PMC10767506 DOI: 10.1016/j.heliyon.2023.e23713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 10/08/2023] [Accepted: 12/12/2023] [Indexed: 01/09/2024] Open
Abstract
This paper answered some authors' requests to analyze the Helping Relationships Skills Inventory psychometric properties, a four dimensions measure. At this level, the study contributed to accessing the first reliable and valid instrument headed to Portuguese nurses and doctors. Methods: An online survey with Portuguese nurses and doctors (n = 262) was managed to assess the psychometrics properties analysis of the Helping Relationships Skills Inventory. Data were analyzed using descriptive statistics, confirmatory factor analysis, the average variance extracted (AVE), the heterotrait-monotrait ratio of correlations (HTMT), Cronbach's Alpha, and McDonald's Omega were computed. Results: The four-factor of the original Helping Relationships Skills Inventory was only supported by Exploratory Factor Analysis, with good internal consistency. Our study accepted this correlational structure hypothesis, which demonstrated acceptable to good sensitivity, convergent validity (AVE: 0.84-0.67), and reliability (Cronbach's Alpha: 0.92-0.88; McDonald'Omega: 0.93-0.79). Also stays verified discriminant validity for the majority of the factors with some reserves between Generics and Emphatics dimensions (HTMT: 0.90), revealing high commonality among them (r = 0.84; p < .001) Conclusions: The findings support the sensitivity, construct validity, and reliability of the Helping Relationships Skills Inventory among Portuguese nurses and doctors. However, will be useful to associate qualitative methodologies to explore the phenomenon better.
Collapse
|
5
|
Relation between the risk factors for the severity of denture stomatitis and quality of life of complete edentulous individuals: a cross-sectional study. J Appl Oral Sci 2023; 31:e20230192. [PMID: 38126577 PMCID: PMC10786452 DOI: 10.1590/1678-7757-2023-0192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 09/30/2023] [Accepted: 10/23/2023] [Indexed: 12/23/2023] Open
Abstract
OBJECTIVE To assess the association between risk factors for developing denture stomatitis (DS) and oral health-related quality of life (OHRQoL) in complete denture wearers. METHODOLOGY Participants of both sexes, wearing complete dentures, were classified using the modified Newton classification for the absence or the severity of DS and allocated to groups Normal or zero, IA, IB, II, and III. Lifestyle, oral and denture history, and medication use were assessed using specific questionnaires; clinical parameters such as anatomical characteristics of support were evaluated with the Kapur classification; salivary flow (SF) was calculated by the volume of unstimulated saliva per minute; and microbial load was determined by counting colony forming units (CFU) of target microorganisms present in the biofilm collected from dentures and palate. OHIP-EDENT assessed the OHRQoL. Kendall's tau_b and Spearman tests were applied with a significance level of 5%. RESULTS 184 patients (143 female and 41 male) aged 65.5 ± 6.8 years were evaluated. Positive correlations were found for sex (women; p=0.013, r=0.16), individuals who started to consume alcoholic beverages as a young adult (18-27 years) (p=0.008, r=0.22), CFU of Candida spp. (p<0.001, r=0.27 denture; p<0.001, r=0.31 palate); Candida albicans (p=0.004, r=0.22 denture; p=0.003, r=0.25 palate), and Candida glabrata (p=0.004, r=0.22 denture; p=0.001, r=0.27 palate). Moreover, negative correlations with DS were found for CFU of Staphylococcus spp. (p=0.004, r=-0.20 palate) and enterobacteria (p=0.002, r=-0.24 palate), as well as a negative correlation between SF (p=0.009, r=-0.193) and DS. The CFU of Staphylococcus spp. and enterobacteria on the palate significantly correlated with OHRQoL. CONCLUSION Being female, consuming alcoholic beverages as a young adult, CFU of Candida spp., Candida albicans, Candida glabrata, and salivary flow may be the most significant risk factors for DS. The microbial load of Staphylococcus spp. and enterobacteria seems to influence the quality of life for complete denture wearers.
Collapse
|
6
|
Action of chitosan-based solutions against a model four-species biofilm formed on cobalt-chromium and acrylic resin surfaces. Gerodontology 2023; 40:472-483. [PMID: 36629151 DOI: 10.1111/ger.12672] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/15/2022] [Indexed: 01/12/2023]
Abstract
OBJECTIVE To evaluate the anti-biofilm action of chitosan, nanoparticulate chitosan, and denture cleanser Nitradine™ against biofilms comprising Candida albicans, Candida glabrata, Staphylococcus aureus, and Streptococcus mutans. BACKGROUND Biofilm removal from removable partial dentures (RPD) is important for success in prosthetic rehabilitation. MATERIALS AND METHODS The anti-biofilm action of the experimental chitosan-based solutions and Nitradine™ was evaluated on acrylic resin and cobalt-chromium alloy through assessing cell viability, cell metabolism, residual aggregated biofilm, and extracellular polymeric substance and biofilm morphology. RESULTS Only chitosan reduced the viability of C. albicans on cobalt-chromium alloy surface, by 98% (a 1.7 log10 reduction in cfu). Chitosan-based solutions neither promoted substantial alteration of the metabolic activity of the four-species biofilm nor reduced the amount of the aggregated biofilm. After immersion in chitosan and nanoparticulate chitosan, viable microorganisms and extracellular polymeric substances distributed over the entire specimens' surfaces were observed. Nitradine™ reduced the viability and metabolic activity of biofilm grown on both surfaces, but it did not remove all aggregated biofilm and extracellular polymeric substances. After immersion in Nitradine™, approximately 35% of the specimens' surfaces remained covered by aggregated biofilm, mainly composed of dead cells. CONCLUSION Although chitosan and Nitradine™ promoted changes in the viability of microorganisms, neither solution completely removed the four-species biofilm from the Co-Cr and acrylic resin surfaces. Thus, isolated use of hygiene solutions is not indicated for biofilm control on RPDs; this requires complementary mechanical removal.
Collapse
|
7
|
Antimicrobial Activity of Experimental Chitosan Solutions on Acrylic Resin and Cobalt-Chromium Surfaces. INT J PROSTHODONT 2023; 36:650. [PMID: 33651027 DOI: 10.11607/ijp.7264] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
PURPOSE To evaluate the application of chitosan as a cleanser in the control of biofilm formation on cobalt-chromium (Co-Cr) alloy and acrylic resin surfaces. MATERIALS AND METHODS In total, 172 Co-Cr discs and 172 acrylic resin discs (14 mm x 3 mm) were contaminated with Streptococcus mutans, Staphylococcus aureus, Candida albicans, or Candida glabrata and incubated for 48 hours. Then, specimens were randomly divided into groups and immersed in the following solutions for 15 minutes: solution without chitosan (WC/control); chitosan solution (CH: 5 mg/mL); chitosan nanoparticle solu.on (CN: 3.8 mg/mL); and effervescent tablet (ET). Biofilm recovery rates (n = 9) were evaluated by counting the colony-forming units (CFU/mL). Biofilm morphology was evaluated using scanning electron microscopy (SEM). Data were compared using the Kruskal-Wallis or ANOVA tests followed by the Tukey post hoc test. RESULTS For acrylic resin, ET showed the lowest number of CFU for S aureus and S mutans (P < .001). CH exhibited intermediate values for S mutans, S aureus, and C albicans; CN exhibited intermediate values for S mutans and S aureus. For C glabrata, there was no sta.s.cal difference between the solu.ons (P = .264). For Co-Cr, ET showed the highest level of antimicrobial action against all microorganisms (P < .001), and CH showed an intermediate level of action against S mutans and S aureus. Against C albicans and C glabrata, there was no significant difference among CH, CN, and WC. CONCLUSIONS Although ET had a broader spectrum of antimicrobial action, CH showed promise as a denture cleanser. Int J Prosthodont 2023;36:e61-e73.
Collapse
|
8
|
Risk factors and immunological biomarkers in denture stomatitis: An observational cross-sectional study. Arch Oral Biol 2023; 155:105799. [PMID: 37672969 DOI: 10.1016/j.archoralbio.2023.105799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Revised: 08/15/2023] [Accepted: 08/27/2023] [Indexed: 09/08/2023]
Abstract
OBJECTIVE Assess risk factors, local and systemic immunological biomarkers in healthy individuals and with Denture Stomatitis (DS). DESIGN For this observational transversal study, 27 participants without DS (Group 0), 24 with moderate DS (Group 1), and 25 with severe DS (Group 2) were assessed for sociodemographic, behavioral, and clinical parameters, microbial load of Candida spp., Staphylococcus spp., Streptococcus mutans, Pseudomonas spp., and enterobacteria, and cytokine and C-reactive protein levels. ANOVA, Fisher's exact, Kruskal-Wallis, Mann-Whitney, Wilcoxon and Pearson's chi-square tests were used for data analysis (α = 0.05). RESULTS Group 1 had a significantly higher mean age compared to the other groups (P = 0.018), but no correlation was identified between age and DS (P = 0.830; r = 0.025). No significant differences were found among the groups for other sociodemographic and behavioral characteristics. Group 1 had significantly older upper and lower dentures; however, no correlation was identified between age of upper (P = 0.522; r = 0.075) and lower (P = 0.143; r = 0.195) dentures and DS. The microbial load of Candida albicans on the dentures (P = 0.035) and Candida spp. on the palate (P = 0.008) of the groups 1 and 2 was higher than group 0. Group 1 and 2 had higher Candida spp. counts on denture (P = 0.003) than group 0. There was no difference among groups for bacterial analyzed. Group 1 showed higher and Group 2 intermediate salivary levels of IL-6 compared to Group 0. There was no difference in the C-reactive protein levels among groups. CONCLUSIONS Microbial load of Candida spp. is the factor with the strongest relationship with DS, with capacity for local signaling through IL-6.
Collapse
|
9
|
Influence of the frameworks of implant-supported prostheses and implant connections on stress distribution. Dent Med Probl 2023; 60:551-557. [PMID: 38100082 DOI: 10.17219/dmp/153060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 07/31/2022] [Accepted: 08/29/2022] [Indexed: 12/18/2023] Open
Abstract
BACKGROUND The maintenance of marginal bone integrity around dental implants continues to be a clinical challenge. It is still unclear whether loading multiple implant-supported prostheses that have different implant connections influences bone resorption. OBJECTIVES The aim of this in vitro study was to compare stress distribution around residual edentulous ridges supported by external hexagon (EH) and Morse taper (MT) implants with screw-retained frameworks obtained with the use of different methods. MATERIAL AND METHODS Three-element implant-supported prostheses with distal cantilevers were manufactured according to different techniques of obtaining the framework: LAS - framework sectioned and welded with a laser; TIG - framework sectioned and welded with tungsten inert gas (TIG); and CCS - framework obtained using a computer-aided design/computer-aided manufacturing (CAD/CAM) system. Occlusal and punctual loading (150 N) was applied to the cantilevers. In the photoelastic stress analysis, the fringe orders (n) were quanitified using the Tardy method, which calculates the maximum shear stress value (τ) at each selected point. RESULTS High stress around the implants and tightening were observed in the TIG group, mainly in the crestal bone region for the EH and MT implant connections. The LAS and CCS frameworks exhibited lower stress for the MT connection under occlusal and punctual loading. CONCLUSIONS The comparative analysis of the models showed that the MT connection type associated with the laser-welded or CAD/CAM frameworks resulted in lower stress values in the crestal bone area, suggesting the preservation of bone tissue in this region.
Collapse
|
10
|
The long-term effect of sub-boiling water on dental unit waterlines and its ability to control cross-contamination in dentistry. Dent Mater J 2023; 42:700-707. [PMID: 37612094 DOI: 10.4012/dmj.2023-051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
This study investigated the effect of water at high temperature on the physical and mechanical properties of polyurethane and on biofilm removal, aiming for its applicability in dental unit waterlines. The evaluations were carried out after simulating a 1-year period of daily immersion and measured changes in color, microhardness, surface roughness, and tensile strength before and after reproducing a disinfection protocol. For antibiofilm activity measurement, fragments of waterline were contaminated with Pseudomonas aeruginosa and submitted to the disinfection protocols. Relative to effects on the physical and mechanical properties, immersion in water at 60°C did not promote changes in color and tensile strength. However, lower values were observed for microhardness and increased values for surface roughness. Regarding antibiofilm action, water at 60°C significantly reduced the microbial load and promoted substantial changes in cells morphology. In conclusion, disinfection with water at 60°C demonstrated possible application in controlling cross-contamination in dentistry.
Collapse
|
11
|
Analysis of stress/strain distribution in dental mini-implants manufactured by additive manufacturing and machining. J Biomed Mater Res B Appl Biomater 2023. [PMID: 37212516 DOI: 10.1002/jbm.b.35282] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 04/09/2023] [Accepted: 05/11/2023] [Indexed: 05/23/2023]
Abstract
The study aimed to analyze the stress/strain distribution of new designs of mini-implants manufactured by machining and additive manufacturing. Four designs were evaluated (Ø2.0 mm × 10 mm): Intra-lock, helical, threaded machined (MN threaded) and threaded by additive manufacturing (AM threaded). Analysis of stress was performed through photoelastic analysis (100 N axial/oblique loads) and analysis of strain by digital image correlation (DIC) (250 N axial/100 N oblique load). Data distribution was verified using the Shapiro-Wilk test and a significance level of 5% was adopted. Quantitative data were analyzed using the non-parametric Kruskal-Wallis test. In photoelastic analysis, the Intra-lock mini-implant showed the highest stresses in the cervical (104 kPa), middle (108 kPa), and apical (212 kPa) thirds. Higher stresses were observed in the oblique loading situation for all designs. For DIC analysis, axial loading, a significant difference was observed for the AM Threaded mini-implants about the other designs in the cervical third (p = .04), with the highest strain value 47 με [10; 76]. In oblique loading, a significant difference between the mini-implants was observed in the middle and apical thirds, with higher strains for the AM threaded design -185 με [-173; 162] (p = .009) and 242 με [87; 372] (p = .013), respectively. In general, the influence of different mini-implant designs and the additive manufacturing method on the stress/strain was observed, in the photoelastic and DIC analysis. The evaluated designs demonstrated a lower concentration of stress/strain in the cervical region compared to the apical region, and higher stress/strain in situations of oblique load compared with axial load.
Collapse
|
12
|
Mechanical comparison of milled fiber-reinforced resin composite and Co-Cr frameworks with different connector cross-sectional geometries: An in vitro study. J Mech Behav Biomed Mater 2023; 141:105759. [PMID: 36905707 DOI: 10.1016/j.jmbbm.2023.105759] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2023] [Revised: 03/01/2023] [Accepted: 03/03/2023] [Indexed: 03/08/2023]
Abstract
This study compared the effect of using milled fiber-reinforced resin composite and Co-Cr (milled wax and lost-wax technique) frameworks for 4-unit implant-supported partial fixed dental prostheses; and also, evaluated the influence of the connector's cross-sectional geometries on the mechanical behavior. Three groups of milled fiber-reinforced resin composite (TRINIA) for 4-unit implant-supported frameworks (n = 10) with three connectors geometries (round, square, or trapezoid), and three groups of Co-Cr alloy frameworks manufactured by milled wax/lost wax and casting technique, were analyzed. The marginal adaptation was measured before cementation using an optical microscope. Then, the samples were cemented, thermomechanical cycled (load of 100 N/2 Hz, 106 cycles; 5, 37, and 55 ᵒC, a total of 926 cycles at each one), and cementation and flexure strength (maximum force) analyzed. Analysis of stress distribution in framework veneered considering resin and ceramic properties for fiber-reinforced and Co-Cr frameworks, respectively, implant, and bone was by finite element analysis under three contact points (100 N) on the central region. ANOVA and Multiple paired test-t with Bonferroni adjustment (α = 0.05) were used for data analysis. Fiber-reinforced frameworks showed better vertical adaptation (mean ranged from 26.24 to 81.48 μm) compared to the Co-Cr frameworks (mean ranged from 64.11 to 98.12 μm), contrary to horizontal adaptation (respectively, means ranged from 281.94 to 305.38 μm; and from 150.70 to 174.82 μm). There were no failures during the thermomechanical test. Cementation strength showed three times higher for Co-Cr compared to fiber-reinforced framework, as well as flexural strength (P < .001). Regarding stress distribution, fiber-reinforced had a pattern of concentration in the implant-abutment complex. There were no significant differences in stress values or changes observed among the different connector geometries or framework materials. Trapezoid connector geometry had a worse performance for marginal adaptation, cementation (fiber-reinforced 132.41 N; Co-Cr 255.68 N) and flexural strength (fiber-reinforced 222.57 N; Co-Cr 614.27 N). Although the fiber-reinforced framework showed lower cementation and flexural strength, considering the stress distribution values and absence of failures in the thermomechanical cycling test, it can be considered for use as a framework for 4-unit implant-supported partial fixed dental prostheses in the posterior mandible. Besides, results suggest that trapezoid connectors mechanical behavior did not perform well compared to round or square geometries.
Collapse
|
13
|
Comparative analysis of Candida spp. isolated from complete denture wearers with and without an HIV diagnosis. J Prosthet Dent 2023; 129:140-146. [PMID: 36192195 DOI: 10.1016/j.prosdent.2022.08.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Revised: 08/16/2022] [Accepted: 08/16/2022] [Indexed: 01/18/2023]
Abstract
STATEMENT OF PROBLEM Denture-related stomatitis (DRS), an inflammation frequently present in human immunodeficiency virus-positive (HIV+) individuals, can be attributable to colonization by Candida spp., which is considered a main factor. The virulence factors of these species are often modulated by the systemic condition of their hosts. PURPOSE The purpose of this clinical study was to evaluate the incidence, virulence, and morphology of Candida spp. isolated from biofilms of complete denture wearers with DRS, with and without an HIV diagnosis. In addition, the interaction of the systemic condition with the ability of Candida spp. to colonize was evaluated. MATERIAL AND METHODS Fifty-five complete denture wearers diagnosed with DRS were divided into 2 groups: experimental (HIV+) and control (human immunodeficiency virus-noninfected participants [HIV-]). Biofilm was collected by a standardized method of ultrasonification of prostheses. The incidence was evaluated by a chromogenic method and polymerase chain reaction (PCR). The virulence factors were assessed by using the capacity for biofilm formation by counting colony-forming units (CFUs/mL), biofilm metabolism by tetrazolium salt metabolization, and proteinase and phospholipase production by using a fluorimetric kit. Morphology was verified by using the hyphae-inducing test, and participants' health data were collected with a form. Data were analyzed by using the Student t, Mann-Whitney U, Spearman, and Fisher tests (α=.05). RESULTS The results of incidence were related to 55 participants (22 experimental and 33 control); in total, 63 Candida spp. samples were isolated, showing 28 Candida albicans and 36 nonalbicans strains. No significant difference was found between groups in baseline CFU/mL counts, biofilm formation capacity, cell metabolism, and phospholipase production. Proteinase production was higher for C. albicans in the control (P=.031) and for nonalbicans in the experimental (P=.016) groups. Relative to health data, the experimental group showed a moderate negative correlation between the CFU count/mL at baseline for nonalbicans and DRS classification (P=.020). CONCLUSIONS C. albicans was the most prevalent species. No difference was found in the Candida spp. of complete denture wearers with DRS, with and without an HIV diagnosis, with regard to virulence factors (except for proteinase production) and morphology.
Collapse
|
14
|
Health management of malnourished elderly in primary health care: a scoping review. BMC PRIMARY CARE 2022; 23:272. [PMID: 36329398 PMCID: PMC9632089 DOI: 10.1186/s12875-022-01883-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Accepted: 05/03/2022] [Indexed: 11/06/2022]
Abstract
Objectives The aim of this study, as the first review directed at Primary Health Care, is to identify the screening practices and health outcomes related to the care provided by Family Health Teams to the malnourished elderly people/population. Methods Following PRISMA and PICO strategies, searches were conducted in four electronic databases (PubMed, Web of Science, Scopus & EMBASE) on observational, qualitative, quantitative, or mixed studies, written in Portuguese, Spanish and English language, with participants of 65 years old or older at a community setting. The literature selected for this study ranges from the period 2011 to 2021; additional articles were included through reference lists. Results From the 483 studies identified, 16 were considered eligible to use in this work. The Mini Nutritional Assessment (MNA) score appears as the main criteria of choice, however, a standardized practice in the health systems regarding the use of screening methods has not been demonstrated. Studies are more oriented towards the analysis of the relationship of mortality/morbidity and malnutrition than towards the relationship of the cost and quality of life and malnutrition of the elderly. Discussion Malnutrition is one of the modifiable risk factors which contributes to the vulnerable condition of the elderly, with serious effects, especially when related to other comorbidities. Yet, several authors argue that the Primary Health Care intervention can minimize the negative impacts and improve the health outcomes.
Collapse
|
15
|
Effect of escitalopram oxalate on quality bone tissue of ovariectomized rats. Bone Rep 2022. [DOI: 10.1016/j.bonr.2022.101533] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
16
|
Effect of Denture Hygiene Protocols on Patient Satisfaction, Oral Health-Related Quality Of Life, and Salivary Parameters: A Randomized Clinical Trial. J Prosthodont 2022; 31:e12-e19. [PMID: 35150590 DOI: 10.1111/jopr.13494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 02/08/2022] [Indexed: 11/27/2022] Open
Abstract
PURPOSE This randomized controlled trial compared four denture hygiene protocols in terms of patient satisfaction, oral health-related quality of life (OHRQoL), and salivary parameters in complete denture wearers with denture stomatitis. MATERIAL AND METHODS For this randomized, double-blind controlled clinical trial, 108 participants were assigned to soak their dentures in one of the following solutions: (1) 0.25% sodium hypochlorite (positive control), (2) 0.15% Triclosan, (3) denture disinfecting tablets, or (4) denture disinfecting tablets plus palatine mucosa brushing solution. The outcomes of patient satisfaction, OHRQoL, and salivary parameters (salivary flow rate and pH) were measured at baseline and after 10 days. Results were compared by Kruskal-Wallis, between-group by the Dunn test, and Wilcoxon tests between times (α = 0.05). RESULTS After the hygiene protocols, and when compared with baseline, the overall patient satisfaction, maxillary denture satisfaction, maxillary denture comfort, and maxillary denture retention were ameliorated. A significant improvement was noted in OHRQoL in 3 of 4 domains evaluated (orofacial pain and discomfort, masticatory discomfort and disability, and psychological disability and discomfort). The salivary flow rate (unstimulated and stimulated); and pH were not significantly affected at the times evaluated. CONCLUSIONS Complete denture wearers may feel more satisfied with their complete dentures when treated for denture stomatitis. The tested treatments lead to similar improvement in terms of patient satisfaction and OHRQoL. This article is protected by copyright. All rights reserved.
Collapse
|
17
|
Photoelastic, microhardness and roughness analysis of zirconia and stainless steel crowns for primary molars. AMERICAN JOURNAL OF DENTISTRY 2022; 35:15-19. [PMID: 35316587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
PURPOSE To compare the stress distribution through photoelasticity, microhardness and roughness of intact crowns of primary molars (CC) and the preformed crowns of stainless steel (SSC) and zirconia (ZC) used in dental restorations in pediatric dentistry. METHODS Six healthy primary molars were selected. For the photoelastic models, the teeth were fixed in photoelastic resin. A load of 100 N was applied, and the models were analyzed by transmission polariscope. The Tardy method was used to quantify the fringe order which calculates the maximum stress (T) value in each selected point. The teeth were prepared for cementation of the crowns. The photoelastic test was repeated for each experimental crown. Knoop microhardness was assessed on the buccal surfaces of the CCs, SSCs, and ZCs using a microhardness tester. Parameters were 50 gf for 5 seconds. Roughness was evaluated using a confocal 3-D laser scanning microscope/software at 216x magnification. Roughness average (Ra) values from each model (expressed in µm) were collected and group means were calculated. The stress distribution, microhardness, and roughness data were compared by using one-way ANOVA and the Tukey's test (α= 0.05). RESULTS There was no difference in the stress distribution for the CCs, SSCs and ZCs. For the microhardness analysis, the ZCs obtained the highest values compared to the CCs and the SSCs (P< 0.001). The CCs were significantly higher than the SSCs (P= 0.027). There was no difference in roughness for the three models (P= 0.615). The SSCs and ZCs showed satisfactory mechanical behavior. CLINICAL SIGNIFICANCE The use of preformed crowns, especially those made of esthetic materials, is currently increasing in the field of pediatric dentistry. The knowledge of mechanical properties of stainless steel- and zirconia-prefabricated crowns provides scientific foundation for safe clinical application, especially in primary teeth.
Collapse
|
18
|
Needle-free anesthesia: clinical efficacy of a mucoadhesive patch for atraumatic anesthesia in dental procedures. Braz Oral Res 2021; 35:e131. [PMID: 34932660 DOI: 10.1590/1807-3107bor-2021.vol35.0131] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2020] [Accepted: 06/02/2021] [Indexed: 11/22/2022] Open
Abstract
This study showcases the clinical efficacy of mucoadhesive patches designed for the buccal delivery of lidocaine and prilocaine hydrochlorides (1:1, 30 mg/patch). Such patches were developed for needle-free pre-operative local anesthesia in dentistry, aiming at mitigating the use of infiltrative anesthesia for medium-complexity clinical procedures. The patches were manufactured encompassing drug-release, mucoadhesive and backing layers, all prepared through film casting using biocompatible materials. Fifty-eight (n = 58) adult patients (65% women and 35% men) were randomly selected and included in a one-arm open clinical prospective cohort study. The average age of the subjects was of 50 years. The majority (59%) of the subjects, mostly women (82%), reported needle-phobia or anxiety due to dental procedures, which was assessed through a questionnaire approved by the ethical council for human use in research. The patches were positioned in the gingival region of the teeth involved in the procedure (86% on the maxillary and 14% on the mandibular bone). Two anesthetic patches were applied on each patient: one in the vestibular region and another in the palate/lingual portion, and these patches remained attached to the placement sites throughout the procedures. Concerning the dental procedures performed, 40% were cavity preparations and dental restorations of medium cavities; 29% staple facilities; 10% gingival retractions; 9% subgingival scrapings; 3% gingivalplasties; 3% supragingival preparations; 3% occlusal adjustments; and 2% subgingival preparations. In 90% of the cases, it was not necessary to complement with conventional infiltrative local anesthesia during the procedures. Patients did not report any discomfort or side effect during or after the administration of the patches. Among the cases in which there was the need for complementation, 50% were cavity preparations and dental restorations; 33% supragingival preparations; and 17% gingivoplasties. The complementary anesthesia volume was of 0.63 ± 0.23 mL and women corresponded to 83% of the participants who needed such intervention. Furthermore, in most cases, the patch was capable of initiating the anesthesia within a short time frame (5 minutes) and reaching the maximum anesthetic effect within 15 and 25 min, lasting at least 50 min. Undesirable side effects were not reported either 2 h after the administration or within the 6-month follow-up. Therefore, the anesthetic patches developed provide needle-free, painless, safe, and patient/dentist-friendly advances in performing routine medium-complexity dental procedures.
Collapse
|
19
|
Evaluation of misfit and stress distribution in implant-retained prosthesis obtained by different methods. Braz Dent J 2021; 32:67-76. [PMID: 34877979 DOI: 10.1590/0103-6440202104453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Accepted: 09/13/2021] [Indexed: 11/22/2022] Open
Abstract
This study evaluated the vertical misfit, passivity, and stress distribution after tightening the screws of different prosthesis. Two implants were used to simulate the rehabilitation of partially edentulous mandible space from the second premolar to the second molar. 40 three-element screw-retained fixed dental prosthesis with distal cantilever were fabricated and divided into four groups according to the method of production of framework (n = 10): G1 = conventional casting one-piece framework, G2 = conventional casting sectioned and laser welding, G3 = conventional casting sectioned and tungsten inert gas (TIG) welding and G4 = framework obtained by CAD/CAM (computer-aided design/computer-aided manufacturing) system. The vertical misfits (both screws tightened) and the passive fit (one screw tightened) were measured under a comparator optical microscope. The data was submitted to Shapiro-Wilk test to enable comparison with ANOVA followed by Tukey with Bonferroni adjust (α = .05). The qualitative analysis of the stress distribution was performed by the photoelastic method. The vertical misfit (both screws tightened) of the G2 (24 μm) and G3 (27 μm) were significantly higher than G4 (10 μm) (p = 0,006). The passive fit (for the non-tightened) of the G1(64 μm) and G3 (61 μm) were significantly higher than the G4 (32 μm) (p=0,009). G1 showed high stress between the implants in the photoelastic analysis and G4 presented lower stress. In conclusion, CAD/CAM method results in less vertical misfit, more passivity, and consequently better stress distribution to the bone.
Collapse
|
20
|
Comparative effects on acrylic resin properties of short- and long-term immersion in alkaline peroxide solution. AMERICAN JOURNAL OF DENTISTRY 2021; 34:322-326. [PMID: 35051320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
PURPOSE To evaluate the color stability (ΔE), surface roughness (ΔRa), and flexural strength of denture base acrylic resin after short (20 minutes) and long-term (8 hours) immersions simulating a period of 5 years of use. METHODS 120 disk-shaped (16 mm x 4 mm) and 120 rectangular (65 mm x 10 mm x 3.3 mm) specimens were prepared (Lucitone 550) and distributed into three groups (n=20): distilled water (Control); Corega Tabs (CT) and Polident (Po), for immersions of 20 minutes and 8 hours. ΔE were determined by a colorimeter, ΔRa by a profilometer and the flexural strength by a universal testing machine. Data were evaluated by two-way ANOVA followed by Tukey's test and Bonferroni correction (α= 0.05). RESULTS Short-term immersions for 20 minutes resulted in significant differences in ΔE, as CT values (1.46 ± 1.41) were higher than Po (0.55 ± 0.25) and Control (0.47 ± 0.21). Specimens immersed for 8 hours showed more extensive alterations overall than the control (ΔE [Po: 7.27 ± 0.53; CT: 5.58 ± 0.49; Control: 1.26 ± 0.23]; 916;Ra [Po: 0.16 ± 0.08; CT: 0.12 ± 0.11; Control: 0.07 ± 0.06]; flexural strength [Po: 42.99 ± 9.34; CT: 63.96 ± 12.98; Control: 64.59 ± 12.87]). The tested alkaline peroxide-based solutions promoted significant alteration on acrylic resin properties after overnight immersion. Therefore, short-term immersions seem to be more suitable for daily denture hygiene. CLINICAL SIGNIFICANCE Alkaline peroxides were able to alter color stability, surface roughness and flexural strength of acrylic resin after overnight immersions, in a 5-year-simulated period of use.
Collapse
|
21
|
In vitro assessment of polyetheretherketone for an attachment component for an implant-retained overdenture. J Prosthet Dent 2021; 127:319.e1-319.e8. [PMID: 34857392 DOI: 10.1016/j.prosdent.2021.07.031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Revised: 07/30/2021] [Accepted: 07/30/2021] [Indexed: 11/26/2022]
Abstract
STATEMENT OF PROBLEM Frequent maintenance because of the limited lifetime of overdenture attachments with O-rings has led to the development of materials that might improve their functionality and longevity. However, testing of newly developed attachment materials is lacking. PURPOSE The purpose of this in vitro study was to evaluate a newly developed attachment made of polyetheretherketone (PEEK) for an implant-retained overdenture. MATERIAL AND METHODS Specimens of PEEK, polyacetal, and Teflon O-ring materials were prepared for analysis of roughness, surface hardness, and compressive strength. For the fatigue resistance test, new specimens based on acrylic resin were subjected to 2880 insertion and removal cycles. Compression and roughness data were compared with the Kruskal-Wallis and Dunn post hoc test; hardness data with ANOVA and t test; and fatigue and stereomicroscopy with ANOVA with repeated measures, t test, and Bonferroni adjustment (α=.05). RESULTS Polyacetal had the lowest surface roughness (P=.038). There was a significant difference in hardness among the materials (P<.05). PEEK presented the highest compressive strength among the materials (P<.001). For the fatigue resistance, only polyacetal showed a difference between the initial time-point (P<.05) and subsequent time-points. Polyacetal had a higher fatigue resistance than Teflon (P<.001) and PEEK (P<.05). Regarding the internal deformation of the attachments, a significant difference was observed among the materials (P<.05). CONCLUSIONS PEEK showed promising results regarding the physicomechanical properties necessary for use as an overdenture attachment when compared with other evaluated materials. In addition, the PEEK attachment showed results comparable to those in the control group (O-rings) in terms of retention.
Collapse
|
22
|
Evaluation of tissue in repair with natural latex and / or hyaluronic acid in surgical bone defects. Braz Dent J 2021; 32:83-95. [PMID: 34787255 DOI: 10.1590/0103-6440202104302] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Accepted: 04/09/2021] [Indexed: 11/22/2022] Open
Abstract
This study evaluated the bone repair in surgical defects of rats treated with hyaluronic acid (HA) associated or not with Hevea brasiliensis fraction protein (F-1). Bone defect were created in 15 albino Wistar rats divided into 3 groups (n=5): Control group (1) - blood clot; HA group (2) - 0.5% hyaluronic acid; HAF1 group (3) - 0.1% F-1 protein fraction dissolved in 0.5% hyaluronic acid. After 4 weeks, the animals were euthanized and the bone repair was evaluated through histomorphometric analysis, zymography and immunohistochemistry. The neoformed bone area did not show a significant difference (p = 0.757), but there was a tendency for bone trabeculation to increase in the groups HA and HAF1. For immunohistochemically analysis, there was a difference in vascular endothelial growth factor (VEGF) labeling (p = 0.023), being higher in the groups HA and HAF1 than the control group. No significant difference in bone sialoprotein (BSP) (p = 0.681), osteocalcin (p = 0.954), however, significant difference in platelet endothelial cell adhesion molecule-1 (CD-31) (p = 0.040), with HAF1 group being significantly lower than the control. For zymographic analysis, there was no significant difference for metalloproteinase-2 (MMP-2) (p = 0.068), but there was a tendency to increase MMP-2 in the HA group. Despite the influence on angiogenic factors and the apparent tendency for greater trabeculation in the HA and HAF1 groups, there was no significant difference in the area of newly formed bone tissue in the analyzed period.
Collapse
|
23
|
Impact of Endodontic Kinematics on Stress Distribution During Root Canal Treatment: Analysis of Photoelastic Stress. J Endod 2021; 48:255-262. [PMID: 34699903 DOI: 10.1016/j.joen.2021.10.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 10/09/2021] [Accepted: 10/14/2021] [Indexed: 11/18/2022]
Abstract
INTRODUCTION Structural defects created by endodontic treatment are the most common cause of major dental failures. This study analyzed levels of stress produced by endodontic instruments during the root canal treatment by photoelastic analysis of stress. METHODS Twenty-four human premolars were randomly divided into 4 groups (n = 6) according to instrumentation protocol: ProTaper Next (GPT), One Shape (GOS), Wave One Gold (GWO), and TF Adaptive (GTF). The evaluation of the photoelastic model was performed at 4 dental zones: dental-crown region, cervical third of root, middle third of root, and apical third of root. Silicone molds were prepared (2 × 15 mm), and pinjets were used inside the root canals to fixate teeth. Photoelastic resin (2:1 ratio) was poured into the silicone molds to form photoelastic models. A transmission polariscope was used to analyze the positions of interest and recorded with a digital camera. Tardy's method was used to quantify the fringe order (n) and calculate the maximum stress value (τ) at each selected point. Data were analyzed with two-way analysis of variance, Tukey test (P < .05), fringe descriptive analysis. RESULTS All groups showed a significant increase in the level of stress created during biomechanical preparation of the root canals. In the quantitative analysis, there was no statistically significant difference among the groups (P > .05). In the qualitative analysis, GPT and GTF instruments achieved greater levels of stresses compared with GWO and GOS instruments. At the beginning of instrumentation, stresses were concentrated at the coronary level and the end of instrumentation at the middle and apical root level. CONCLUSIONS All endodontic systems resulted in accumulation of stress along the dental structure. Stress was found in different concentrations along the tooth and at different levels.
Collapse
|
24
|
Effect of oxidation heat treatment with airborne-particle abrasion on the shear bond strength of ceramic to base metal alloys. J Prosthet Dent 2021; 126:804.e1-804.e9. [PMID: 34654570 DOI: 10.1016/j.prosdent.2021.08.013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Revised: 08/04/2021] [Accepted: 08/05/2021] [Indexed: 10/20/2022]
Abstract
STATEMENT OF PROBLEM Oxidation heat treatment has been studied to increase the metal-ceramic bond strength. However, information about its use with cobalt-chromium (Co-Cr) alloys is lacking. PURPOSE The purpose of this study was to evaluate the effect of oxidation heat treatment and oxidation heat treatment with alumina airborne-particle abrasion on the metal-ceramic bond strength of Co-Cr alloys compared with that of nickel-chromium (Ni-Cr) alloys. MATERIAL AND METHODS In total, 165 metal cylinders (∅5×8 mm) made of 5 base metal alloys were obtained by casting: 2 Ni-Cr (Fit Cast-SB and Fit Cast-V) and 3 Co-Cr alloys (Keragen, StarLoy C, and Remanium 2001). The specimens were divided into groups (n=11): no treatment, oxidation heat treatment, and oxidation heat treatment with airborne-particle abrasion. Oxidation heat treatment was performed starting at 650 °C and rising to 980 °C. The airborne-particle abrasion was performed with 100-μm alumina (0.2-MPa pressure, 5 seconds). One specimen had the surface topography and composition evaluated by scanning electron microscopy and energy dispersive X-ray spectrometry. The feldspathic ceramic was applied to the base metal alloy specimens (n=10). Shear tests were performed to obtain the metal-ceramic bond strength (MPa). The failure modes were evaluated. Data were evaluated by 2-way ANOVA and the Tukey post hoc test, Pearson correlation, and Fisher exact tests (α=.05). RESULTS The group without treatment showed the highest roughness. The treatments increased oxygen and chromium levels and decreased nickel, molybdenum, and tungsten levels. Oxidation heat treatment provided an increase in metal-ceramic bond strength (P<.05) for base metal alloys with over 7% molybdenum (Fit Cast-SB, Fit Cast-V, and Remanium 2001). With oxidation heat treatment with airborne-particle abrasion, there was improvement only in Fit Cast-SB. No treatment was better for StarLoy C. A weak correlation was found between metal-ceramic bond strength and failure mode (ρ=.166; P=.043). The mixed failures were prevalent in Co-Cr alloys (P<.001) and oxidation heat treatment with airborne-particle abrasion (P=.008). CONCLUSIONS The oxidation heat treatment was only beneficial for base metal alloy with a molybdenum content of over 7%. Although the oxidation heat treatment with alumina airborne-particle abrasion was a better treatment for Fit Cast-SB, its use is not justified because it showed no difference for oxidation heat treatment and requires another step in the surface treatment.
Collapse
|
25
|
Action of disinfectant solutions on adaptive capacity and virulence factors of the Candida spp. biofilms formed on acrylic resin. J Appl Oral Sci 2021; 29:e20210024. [PMID: 34495107 PMCID: PMC8425898 DOI: 10.1590/1678-7757-2021-0024] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Accepted: 04/19/2021] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Understanding the behavior of Candida spp. when exposed to denture disinfectants is essential to optimize their effectiveness. Changes in the virulence factors may cause increased resistance of Candida spp. to disinfectant agents. OBJECTIVE To evaluate the microbial load, cellular metabolism, hydrolytic enzyme production, hyphae formation, live cell and biofilm quantification of Candida albicans, Candida tropicalis and Candida glabrata after exposure to disinfectant solutions. METHODOLOGY Simple biofilms were grown on heat-polymerized acrylic resin specimens, and divided into groups according to solutions/strains: distilled water (control); 0.25% sodium hypochlorite (NaOCl 0.25% ); 10% Ricinus communis (RC 10%); and 0.5% Chloramine T (CT 0.5%). The virulence factors were evaluated using the CFU count (microbial load), XTT method (cell metabolism), epifluorescence microscopy (biofilm removal and live or dead cells adhered), protease and phospholipase production and hyphae formation. Data were analyzed (α=0.05) by one-way ANOVA/ Tukey post hoc test, Kruskal-Wallis test and Wilcoxon test. RESULTS NaOCl 0.25% was the most effective solution. CT 0.5% reduced the number of CFUs more than RC 10% and the control. RC 10% was effective only against C. glabrata. RC 10% and CT 0.5% decreased the cellular metabolism of C. albicans and C. glabrata. Enzyme production was not affected. Hyphal growth in the RC 10% and CT 0.5% groups was similar to that of the control. CT 0.5% was better than RC 10% against C. albicans and C. tropicalis when measuring the total amount of biofilm and number of living cells. For C. glabrata, CT 0.5% was equal to RC 10% in the maintenance of living cells; RC 10% was superior for biofilm removal. CONCLUSIONS The CT 0.5% achieved better results than those of Ricinus communis at 10%, favoring the creation of specific products for dentures. Adjustments in the formulations of RC 10% are necessary due to efficacy against C. glabrata. The NaOCl 0.25% is the most effective and could be suitable for use as a positive control.
Collapse
|
26
|
Complete denture hygiene solutions: antibiofilm activity and effects on physical and mechanical properties of acrylic resin. J Appl Oral Sci 2021; 29:e20200948. [PMID: 34495105 PMCID: PMC8425897 DOI: 10.1590/1678-7757-2020-0948] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Accepted: 04/18/2021] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Appropriated denture hygiene is a predictive factor for longevity of rehabilitation treatment and maintenance of the oral mucosal health. Although, disinfectant solutions are commonly used as denture cleansers, the impact of these solutions on acrylic resin-based dentures remain unclear. OBJECTIVE To evaluate, in vitro, the antibiofilm activity of complete denture hygiene solutions and their effects on physical and mechanical properties of acrylic resin. METHODOLOGY For antibiofilm activity measurement acrylic resin specimens were contaminated with Candida albicans, Candida glabrata and Streptococcus mutans. After biofilm growth, the specimens were assigned to the hygiene solutions: Distilled water (Control); 0.2% Sodium hypochlorite (SH); Efferdent Power Clean Crystals (EPC) and 6.25% Ricinus communis (RC). The viability of microorganisms was evaluated by agar plate counts. In parallel, physical, and mechanical properties of the acrylic resin were evaluated after simulating a 5-year period of daily immersion in the previously mentioned solutions. The changes in surface roughness, color, microhardness, flexural strength, impact strength, sorption and solubility were evaluated. Data were compared by ANOVA followed by the Tukey test or Kruskal-Wallis followed by the Dunn test depending on the distribution (α=0.05). RESULTS Regarding antibiofilm action, SH eliminated all microorganisms while EPC and RC exhibited moderate action against S. mutans (p=0.001) and C. glabrata (p<0.001), respectively. Relative to effects on the physical and mechanical properties of the acrylic resin, RC led to higher values of color change (p=0.030), hardness (p<0.001), surface roughness (p=0.006) and flexural strength (p<0.001). Moreover, RC induced the highest values of changes in solubility (p<0.001). EPC promoted greater changes in surface morphology, whereas immersion in SH retained the initial appearance of the acrylic resin surface. All hygiene solutions reduced the impact strength (p<0.05). CONCLUSION SH presented the most effective antibiofilm activity. In addition, changes on properties were observed after immersion in RC, which were considered within acceptable limits.
Collapse
|
27
|
Distal radius fracture fixation using volar plate: A comparative study evaluating the biomechanical behavior of uni and bicortical distal screws. Injury 2021; 52 Suppl 3:S38-S43. [PMID: 34172266 DOI: 10.1016/j.injury.2021.02.031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 02/09/2021] [Accepted: 02/11/2021] [Indexed: 02/02/2023]
Abstract
Extensor tendon ruptures caused by bicortical screws impingement following distal radius fracture fixation with volar plates are extensively reported in the literature. Thus, a biomechanical study comparing unicortical and bicortical fixations in intra-articular distal radius fracture models is critical in decision-making regarding distal radius fracture management. Forty-two synthetic radius models were fixed using a variable angle volar distal locking plate with seven screws. They were divided into 6 groups (n = 7): G1/G3/G4 unicortical fixation (75% of anteroposterior distal radius lenght); G2/G4/G6 bicortical fixation. Each group underwent a different mechanical test: axial compression (G1/G2), dorsal flexion (G3/G4), and volar flexion (G5/G6). The load application rate was 5 mm/min and 1000 cycles of 50 to 250 N at 1 Hz were performed between both static tests. Comparative results in the first static test, in the second static test, and in failure generally showed a very similar behavior. Models depicted similar behavior in the second static test when cyclic load was performed. Therefore, one can realize that stiffness differed during dorsal flexion only in the first static test. Maximum force to break the model in axial compression was greater in bicortical than in unicortical construct. Since biomechanical properties are similar, we recommend using unicortical distal locking screws in distal radius fracture fixation with volar plates to prevent extensor tendon ruptures.
Collapse
|
28
|
Biomechanical evaluation of a new femoral stem design for total hip replacement in a canine model. Acta Cir Bras 2021; 36:e360506. [PMID: 34161433 PMCID: PMC8221799 DOI: 10.1590/acb360506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2021] [Accepted: 04/14/2021] [Indexed: 11/22/2022] Open
Abstract
PURPOSE To evaluate the biomechanical properties of a novel total hip replacement femoral stem. METHODS Eight pairs of femurs from dog cadavers were used. The femurs were separated into different groups. A novel femoral stem with a convex proximal portion (Stem B) was biomechanically evaluated and compared to awell-known veterinary collared stem (Stem A). Femoral stems were inserted into the contralateral femurs from the same dog, forming 16 constructs. A flexo-compression load was applied on the axial axis of each sample. Maximum strength, deflection, stiffness, and energy absorption were analysed. RESULTS Group B constructs showed significantly higher values (p ? 0.05) for the variables, except stiffness. The mean maximum strength was 1,347 ± 357 N for Group A and 1,805 ± 123 N for Group B (p ? 0.0069). The mean deflection was5.54 ± 2.63 mm for Group A and 10.03 ± 3.99 mm for Group B (p ? 0.0056). For the energy variable, the force was 6,203 ± 3,488 N/mm for Group A and 12,885 ± 5,056 N/mm for Group B (p ? 0.0054). Stem B had greater maximum strength, deflection, and energy. CONCLUSIONS The new stem was effective in neutralizing the impact of axial flexion-compression stresses during biomechanical tests in cadaveric models.
Collapse
|
29
|
Effectiveness of Brushing Associated With Oral Irrigation in Maintenance of Peri-Implant Tissues and Overdentures: Clinical Parameters and Patient Satisfaction. J ORAL IMPLANTOL 2021; 47:117-123. [PMID: 32662827 DOI: 10.1563/aaid-joi-d-19-00092] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Hygiene of implant-supported prostheses and the health of peri-implant tissues are considered to be predictive factors of successful prosthetic rehabilitation. Therefore, the purpose of this study was to evaluate the effectiveness of brushing associated with oral irrigation measured as biofilm-removing capacity, maintenance of healthy oral tissues, and patient satisfaction. A randomized, crossover clinical trial was conducted with 38 patients who wore conventional maxillary complete dentures and mandibular overdentures retained by the O-ring system. The patients were instructed to use the following hygiene methods for 14 days: mechanical brushing (MB; brush and dentifrice, control) and MB with oral irrigation (Waterpik [WP], experimental). Biofilm-removing capacity and maintenance of healthy oral tissues were evaluated by the modified plaque index (PI), gingival index (GI), probing depth (PD), and bleeding on probing index (BP) recorded at baseline and after each method. In parallel, patients answered a specific questionnaire using a visual analog scale after each hygiene method. Data were analyzed by Friedman and Wilcoxon tests (α = .05). The results showed significantly lower PI, GI, PD, and BP after application of the hygiene methods (P < .001) than those observed at baseline. However, no significant difference was found between MB and WP. The responses to the satisfaction questionnaire for both methods showed high mean values for all questions, with no statistically significant difference found between the answers given after the use of MB and WP (P > .05). The findings suggest that WP was effective in reducing PI, GI, PD, and BP indices and provided a high level of patient satisfaction.
Collapse
|
30
|
The Impact of an Ocular Prosthesis on the Quality of Life, Perceived Stress, and Clinical Adaptation of Anophthalmic Patients: A Clinical and Longitudinal Trial. J Prosthodont 2021; 30:394-400. [PMID: 33464687 DOI: 10.1111/jopr.13332] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/12/2021] [Indexed: 11/28/2022] Open
Abstract
PURPOSE This prospective study evaluated and correlated the impact of ocular prostheses on quality of life and stress with socioeconomic level and clinical characteristics. The clinical difficulties and perceptions of patients after ocular rehabilitation were evaluated. MATERIALS AND METHODS Anophthalmic patients (at least 18 years of age) who were not users of ocular prostheses were recruited. The Medical Outcomes Short-Form Health Survey (SF-36) and Perceived Stress Scale (PSS-10) questionnaires were administered before and after 3 and 6 months of prosthesis installation. Clinical characteristics, difficulties, and perceptions were evaluated by quantitative and descriptive analysis (7 days, 3 months, 6 months). Data were analyzed by the Friedman test and Pearson Correlation test (α = 0.05). RESULTS The final sample consisted of 26 patients. Quality of life showed improvement in the "Bodily Pain" and "General Health" domains. Wearing the prosthesis did not influence perceived stress. The clinical evaluation showed clinical discharge over 6 months and presence of pain only at 7 days. A weak correlation occurred between sociodemographic characteristics and the categories "Role-Physical" (r = 0.423) and "General Health" (r = 0.494); cause of anophthalmia and "Role-Physical" (r = -0.471); and type of surgery and "General Health" (r = -0.432). CONCLUSIONS According to the results of this study, the provision of ocular prostheses showed positive influence in 2 domains of quality of life and weak correlations with socioeconomic level, type of surgery, and cause of loss. Ocular rehabilitation did not influence stress. The use and care of the prostheses did not affect tissue inflammation, but the discharge was continuous.
Collapse
|
31
|
Stress distribution analysis of novel dental mini-implant designs to support overdenture prosthesis. J ORAL IMPLANTOL 2021; 48:79-83. [PMID: 33690819 DOI: 10.1563/aaid-joi-d-19-00354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
This study aimed to test and compare two novel dental mini-implant designs to support overdentures with a commercial model, regarding the stress distribution, by photoelastic analysis. Three different mini-implant designs (Ø 2.0 mm × 10 mm) were tested: G1-experimental threaded (design with threads and 3 longitudinal and equidistant self-cutting chamfers), G2-experimental helical (design with 2 long self-cutting chamfers in the helical arrangement), and G3-Intra-Lock® System. After including the mini-implants in a photoelastic resin, they were subjected to a static load of 100 N under two situations: axial and inclined model (30°). The fringe orders (n), that represents the intensity of stresses were analyzed around the mini-implants body and quantified using Tardy's method that calculates the maximum shear stress (τ) value in each point selected. In axial models, less stress was observed in the cervical third mini-implants, mainly in G1 and G2. In inclined models (30°), higher stresses were generated on the opposite side of the load application, mainly in the cervical third of G2 and G3. All mini-implant models presented lower tensions in the cervical third compared with the middle and apical third. The new mini-implants tested (G1 and G2) showed lower stresses than the G3 in the cervical third under axial load, while loading in the inclined model generated greater stresses in the cervical of G2.
Collapse
|
32
|
Using denture cleansers to control biofilm from dentures and brushes: A randomized crossover clinical trial. INT J PROSTHODONT 2021; 34:291–299. [PMID: 33616555 DOI: 10.11607/ijp.6665] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
PURPOSE To evaluate the effects of 0.2% sodium hypochlorite, Efferdent (Prestige Consumer Healthcare), and 6.25% Ricinus communis on biofilm removal and antimicrobial action on dentures and brushes using nonimmersion or immersion protocols for the brushes. MATERIALS AND METHODS A total of 45 denture wearers were randomly assigned to a denture immersion protocol for 7 days: 0.85% saline solution for 20 minutes (control); 0.2% sodium hypochlorite for 20 minutes (SH); Efferdent for 3 minutes; or 6.25% Ricinus communis for 20 minutes (RC). The participants were also randomized to immersion (n = 23) or no immersion (n = 22) of their brushes with their dentures in the same solutions. For biofilm evaluation, the dentures were stained and photographed, and the area of the biofilm was measured using Image Tool 3.0 (University of Texas Health Science Center). To evaluate microbial load on dentures and brushes, the biofilm was collected, and the Candida spp and Streptococcus mutans colonies were counted. RESULTS The SH, Efferdent, and RC groups showed reduced biofilm and Candida spp on dentures regardless of the immersion protocol for the brushes. However, no difference was found in the Candida spp counts collected from the brushes immersed compared to the brushes not immersed in the solutions. The SH and Efferdent groups showed reduced S mutans on both dentures and brushes, except for in the nonimmersion subgroups. CONCLUSION All solutions reduced denture biofilm and microbial load. However, immersion of brushes in the solutions did not contribute to reducing the microbial load.
Collapse
|
33
|
Local anesthetic improves individuals affected with herpes simplex type 1 labialis. J Med Virol 2020; 92:3638-3644. [PMID: 32374443 DOI: 10.1002/jmv.25982] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2020] [Accepted: 05/01/2020] [Indexed: 11/07/2022]
Abstract
Infections caused by the herpes simplex virus 1 (HSV-1), commonly called herpes simplex labialis (HSL), are a public health problem, reaching around 40% of the world's population. Thus, the search for effective therapeutic alternatives in the control of the limitations caused by this virus during the stages of evolution of the disease, is necessary, since they have a direct impact on the quality of life of the patients. The aim of the present study was to evaluate the efficacy of the in situ film precursor semisolid composition in the treatment of herpes simplex lesions in human HSV-1. Ninety-eight (n = 98) patients with HSV-1 were used for this study. The initial exclusion criteria left 81 patients to be considered in the present study. Three applications were performed, the first at time zero (T0) and the other two at 8 and 16 hours, after initial application (T8 and T16). Photographs were taken in the first appointment and 24 and 72 hours after the last application. After the three periods, each patient received a total amount of 90 mg of anesthetic and the prognosis of the patients was followed for 6 months and 1 year after the application. Frequency analysis showed that 40.3% of patients had remission of symptoms 24 hours after the last application. For the present study, the film presented a positive therapeutic potential and an esthetic benefit that is absent in the current products (ointments and gels). The invent presents dosage convenience (only three applications in a 24-hour period) and a low production cost, with a much shorter healing time than that reported using topical antiretrovirals.
Collapse
|
34
|
Effect of Cleanser Solutions on the Retention Force of O'ring Attachment: An in Vitro Study. Braz Dent J 2020; 31:657-663. [PMID: 33237238 DOI: 10.1590/0103-6440202003268] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 07/01/2020] [Indexed: 11/22/2022] Open
Abstract
The aim of this study was to evaluate the effect of cleaning solutions on the retention force of o-ring-type overdenture attachments. The effect of four solutions on nitrile rings were evaluated: Cepacol (C), Cepacol with fluoride (CF), Listerine (L) and 0.05% sodium hypochlorite (SH); deionized water (DW) was used as a control. Matrices containing two implants and abutments and acrylic specimens with the metal capsules were obtained and divided into the groups. A simulation of 90 overnight immersions (8 h) was performed, and the tensile strength value was obtained at the beginning (T0) and in every 30 days (T1, T2 and T3) (n=6). In order to analyze o-ring surface damage after the immersions, a scanning electron microscopy (SEM) was used (n=1). For statistical analysis of the results, analysis of variance (ANOVA) and multiple comparisons with Bonferroni adjustment (test power=1.000; a=0.05) were used. There was a significant difference for the factors time (p<0.001), solution (p<0.001) and for the interaction time × solution (p<0.001). Considering the times of each solution, only for DW there was no significant loss of retention over time. Comparing the solutions in each moment, there was no difference among the solutions in T0. From T1, CF and SH provided less retention than DW (p<0.005). Through SEM it was possible to observe changes in the surface of the CF and SH nitrile o-rings. CF and SH should be avoided due to deleterious action in o-rings.
Collapse
|
35
|
Identification and Characterization of New Bacteriophages to Control Multidrug-Resistant Pseudomonas aeruginosa Biofilm on Endotracheal Tubes. Front Microbiol 2020; 11:580779. [PMID: 33123112 PMCID: PMC7573221 DOI: 10.3389/fmicb.2020.580779] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Accepted: 09/08/2020] [Indexed: 12/28/2022] Open
Abstract
Studies involving antimicrobial-coated endotracheal tubes are scarce, and new approaches to control multidrug-resistant Pseudomonas aeruginosa biofilm on these devices should be investigated. In this study, five new P. aeruginosa bacteriophages from domestic sewage were isolated. All of them belong to the order Caudovirales, Myoviridae family. They are pH and heat stable and produce 27 to 46 particles after a latent period of 30 min at 37°C. Their dsDNA genome (ranging from ∼62 to ∼65 kb) encodes 65 to 89 different putative proteins. They exhibit a broad lytic spectrum and infect 69.7% of the P. aeruginosa strains tested. All the bacteriophages were able to reduce the growth of P. aeruginosa strains in planktonic form. The bacteriophages were also able to reduce the biofilm viability rates and the metabolic activity of P. aeruginosa strains in a model of biofilms associated with endotracheal tubes. In addition, scanning electron microscopy micrographs showed disrupted biofilms and cell debris after treatment of bacteriophages, revealing remarkable biofilm reduction. The lytic activity on multidrug-resistant P. aeruginosa biofilm indicates that the isolated bacteriophages might be considered as good candidates for therapeutic studies and for the application of bacteriophage-encoded products.
Collapse
|
36
|
Genomic Evaluation of Formed Biofilm on Dental Implants with Different Surface Treatments Associated with Zirconia or Titanium Abutments: An In Vitro Study. Int J Oral Maxillofac Implants 2020; 35:888-899. [PMID: 32991638 DOI: 10.11607/jomi.8239] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
PURPOSE The aim of this study was to evaluate the formed biofilm on two types of implant surfaces (hydrophilic or hydrophobic) associated with titanium (Ti) or zirconia (Zn) abutments. MATERIALS AND METHODS Samples were separated into four groups according to type of surface and abutment used (n = 10): (1) hydrophobic/Ti abutment, (2) hydrophilic/Ti abutment, (3) hydrophobic/Zn abutment, and (4) hydrophilic/Zn abutment. Implant-abutment assemblies were incubated with human saliva and supragingival biofilm. Samples of biofilm were evaluated by DNA Checkerboard hybridization, identifying up to 41 species. Scanning electron microscopy (SEM) images were obtained from the implants and abutments. RESULTS The microbial count was higher for samples from groups with the hydrophilic/Ti abutment, followed by hydrophobic/Zn abutment, hydrophilic/Ti abutment, and hydrophobic/Zn abutment (P < .05). Hydrophilic surfaces and Zn abutments showed the highest counts of microorganisms. Individual bacterial counts were variable between groups; the hydrophilic/Zn abutment group had the highest microbial diversity, including T forsythia, P nigrescens, S oralis, S sanguinis, L casei, M orale, P aeruginosa, P endodontalis, S aureus, S gallolyticus, S mutans, S parasanguinis, S pneumoniae, and C albicans. The hydrophilic/Ti abutment group had the highest count of T forsythia and T denticola, microorganisms of Socransky red complex. The SEM images showed the bacterial colonization in both surfaces of the implant and abutment. CONCLUSION Different surfaces of implants and abutments showed significant differences in the count and diversity of species. The hydrophilic/Zn abutment group presented the highest count and diversity of target species.
Collapse
|
37
|
Microstructural effects of collagen membrane from bovine pericardium in bone defects. Bone Rep 2020. [DOI: 10.1016/j.bonr.2020.100304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
38
|
Effects of the escitalopram oxalate on densitometric parameters at the intact and bone callus in growing and young adult rats. Bone Rep 2020. [DOI: 10.1016/j.bonr.2020.100308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
39
|
Effects of electroacupuncture on bone defect regeneration in tíbias of ovariectomized rats. Bone Rep 2020. [DOI: 10.1016/j.bonr.2020.100306] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/23/2022] Open
|
40
|
Coated latex membrane with calcium β-triphosphate in bone healing of tibia of osteopenic rats. Bone Rep 2020. [DOI: 10.1016/j.bonr.2020.100305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
41
|
Antimicrobial activity of effervescent denture tablets on multispecies biofilms. Gerodontology 2020; 38:87-94. [PMID: 33000876 DOI: 10.1111/ger.12500] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 09/03/2020] [Accepted: 09/05/2020] [Indexed: 01/27/2023]
Abstract
PURPOSE To investigate the impact of peroxide-based solutions in reducing viability and metabolic activity of multispecies biofilms on denture base acrylic resin surfaces and for removing them from these surfaces. BACKGROUND Denture cleansers are effective in reducing monospecies biofilm; however, studies evaluating their action on multispecies biofilms are scarce. MATERIALS AND METHODS Sixty-nine denture base acrylic resin specimens (Ø 15 × 3 mm) were sterilised then contaminated with Candida albicans, Staphylococcus aureus and Pseudomonas aeruginosa to form multispecies biofilms. Biofilms were grown for 24 hours; subsequently, specimens were immersed in three different cleansing solutions (n = 9): nitradine (NI), fixodent (FX) and phosphate-buffered saline (Control), according to the respective manufacturer's instructions. After applying the hygiene protocols, viability of microorganisms was evaluated by counting colony-forming units and assessing metabolic activity. Moreover, biofilm removal capacity was estimated based on extension of cell-covered areas visualised in fluorescent microscopy micrographics. RESULTS Microbial counts were solution-dependent; NI was effective against all microorganisms (P < .05). FX exhibited moderate antimicrobial action, reducing P aeruginosa (P < .05) and S aureus (P < .05) viability by approximately 2 logs. Both peroxide-based solutions reduced metabolic activity (P < .001) and biofilm-covered areas on specimen surfaces (P < .001). CONCLUSION Under the experimental conditions tested, these results demonstrated that peroxide-based solutions had favourable antimicrobial activity but promoted no broad elimination of aggregated multispecies biofilm. NI might be more suitable as complementary chemical agent for controlling multispecies denture biofilm.
Collapse
|
42
|
Prevalence and susceptibility profile of Candida spp. isolated from patients in cancer therapy. Arch Oral Biol 2020; 119:104906. [PMID: 32947164 DOI: 10.1016/j.archoralbio.2020.104906] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 08/27/2020] [Accepted: 08/28/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVE This study determined the prevalence of Candida spp. in the saliva of cancer patients. Furthermore, we assessed the antimicrobial activity of mouthwashes against the isolated strains and its susceptibility to amphotericin B and fluconazole. METHODS Thirty-four cancer patients undergoing radiotherapy, chemotherapy alone or combined treatment were investigated for oral Candida spp. colonization and compared in regard to mucositis presence. The maximum inhibitory dilution was used to assess the antimicrobial activity of Periogard®, Cepacol® Cool Ice and 0.12 % Chlorhexidine Digluconate mouthwashes against the isolates. In parallel, susceptibility to amphotericin B and fluconazole was determined by agar-based E-test. Data did not adhere to normal distribution as inferred by the Shapiro-Wilk test and statistical analysis was conducted by non-parametric McNemar test (α0.05). RESULTS Twenty-seven participants (79.4 %) were male, 19 (55.9 %) had mucositis and 9 (26.5 %) were colonized by Candida spp. 12 different strains of Candida spp. were isolated, being Candida albicans the most prevalent strain. Risk of Candida spp. colonization was increased by almost twofold among the participants with mucositis (odds ratio: 1.84; 95 % confidence interval: 0.37-9.07). Mouthwash Cepacol® Cool Ice presented better antimicrobial activity against Candida spp. while 0.12 % Chlorhexidine exhibited the worst activity. All strains were sensitive to amphotericin B, and 2 non-albicans strains were dose-dependent sensitive to fluconazole. CONCLUSION Considering the increased risk of colonization byCandida spp. in patients with mucositis, and the emergence of antifungal drug resistance, the antiseptics use could benefit the maintenance of cancer patient's oral health.
Collapse
|
43
|
Topical pilocarpine for xerostomia in patients with head and neck cancer treated with radiotherapy. Oral Dis 2020; 26:1209-1218. [PMID: 32248594 DOI: 10.1111/odi.13343] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Revised: 03/13/2020] [Accepted: 03/18/2020] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To evaluate a pilocarpine spray as a treatment for xerostomia in patients treated with radiotherapy (RT) for head and neck cancer (HNC). METHODS This was a placebo-controlled, double-blind, crossover clinical trial of patients complaining of dry mouth after RT for HNC. Forty patients were randomly assigned to either placebo or pilocarpine (1.54%) spray and instructed to use three times a day for 3 months. After 1-month washout period, patients were crossed over to receive placebo or pilocarpine. The assessments were salivary flow (Stimulated Whole Saliva Flow - SWSF), xerostomia (Xerostomia Inventory - XI), and quality of life (QoL/Oral Health Impact Profile - OHIP-14), assessed at baseline, 1 hr (only SWSF), and at 1, 2, and 3 months of treatment. RESULTS Posttreatment SWFS was not statistically different between pilocarpine and placebo regardless of the treatment sequence (paired T test; p > .05), except for the SWFS rates at 2 months after therapy. When comparing pilocarpine with placebo in the time points, there was no significant difference (p > .05) for QoL or XI. Significant differences in improvement in QoL and xerostomia experience appeared along time for pilocarpine group. CONCLUSION The topical application of pilocarpine spray tested was similar to placebo on SWSF assessments in patients treated with RT for HNC.
Collapse
|
44
|
Brushing associated with oral irrigation in maintaining implants and overdentures hygiene - a randomized clinical trial. Odontology 2020; 109:284-294. [PMID: 32749561 DOI: 10.1007/s10266-020-00543-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Accepted: 07/22/2020] [Indexed: 10/23/2022]
Abstract
Evaluate, through a randomized clinical trial, the efficacy of brushing associated with oral irrigation in maintaining implant and overdenture hygiene. Thirty-eight participants, who had a clinically acceptable conventional maxillary complete denture and mandibular overdenture retained by either implants or mini-implants using an O-ring-retained system, were enrolled to participate in the study. They were instructed to use two different hygiene methods, in a random sequence for a period of 14 days, with a 7-day wash-out interposed period: (I) mechanical brushing (MB); (II) association of mechanical brushing with oral irrigation (WP). Biofilms from both subgingival sulci and overdentures were collected and processed by Checkerboard DNA-DNA hybridization method at baseline and after using the proposed hygiene protocols. Comparisons were performed using Wilcoxon test and Friedman test with Benjamini-Hochberg false discovery rate, followed by Conover post-hoc test (α = 0.05). In the subgingival sulci-related biofilm, a lower number of microbial cells were detected, after WP compared to the MB method (P < 0.001). The findings of overdenture-related biofilm suggest that both methods were similar (P = 0.607) being the identified microbiota qualitatively coincident after each method. Despite the number of microbial counts, it was concluded that the association of mechanical brushing with oral irrigation was more effective in reducing microorganisms in the subgingival sulci biofilm; however, the same outcome was not observed in the overdentures.
Collapse
|
45
|
Biosafety of Non-Return Valves for Infusion Systems in Radiology. Sci Rep 2020; 10:9574. [PMID: 32533091 PMCID: PMC7293231 DOI: 10.1038/s41598-020-66491-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Accepted: 05/13/2020] [Indexed: 11/09/2022] Open
Abstract
Cross-infection in contrast injectors is still a subject under discussion with little understanding. This study evaluated the biosafety of non-return valves (NRVs). Initially, the maximum pressure during backflow of intact and disrupted flexible diaphragms (FDs) from NRVs, as well as the functionality of connectors with NRVs were verified. The performance of air columns interposed by water in connectors with NRVs was analyzed, and the diffusion distance of crystal violet through connectors with NRVs was measured. The efficacy of NRVs as a barrier to bacterial contamination from backflow was evaluated. Finally, a clinical study of bacteriological contamination from syringes was conducted. There were differences among the maximum tolerated pressure by intact and disrupted FDs. Disrupted FDs showed no failures in the functionality of connectors with NRVs based on the lack of air bubbles released. Air columns could move through connectors with NRVs with intact and disrupted FDs. The longest diffusion distance of crystal violet was 6 cm of connector length, and NRVs showed efficacy as a barrier to bacterial contamination. In the clinical study, there was no bacterial growth in any of the evaluated samples. In conclusion, biosafety depends on the functionality of NRVs as well as proper practical clinical performance.
Collapse
|
46
|
Comparison of Conventional and Pontic Fixed Partial Dentures Over Implants Using the Finite Element Method: Three-Dimensional Analysis of Cortical and Medullary Bone Stress. J ORAL IMPLANTOL 2020; 46:175-181. [PMID: 32030425 DOI: 10.1563/aaid-joi-d-19-00115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Rehabilitation with implant prostheses in posterior areas requires the maximum number of possible implants due to the greater masticatory load of the region. However, the necessary minimum requirements are not always present in full. This project analyzed the minimum principal stresses (TMiP, representative of the compressive stress) to the friable structures, specifically the vestibular face of the cortical bone and the vestibular and internal/lingual face of the medullary bone. The experimental groups were as follows: the regular splinted group (GR), with a conventional infrastructure on 3 regular-length Morse taper implants (4 × 11 mm); and the regular pontic group (GP), with a pontic infrastructure on 2 regular-length Morse taper implants (4 × 11 mm). The results showed that the TMiP of the cortical and medullary bones were greater for the GP in regions surrounding the implants (especially in the cervical and apical areas of the same region) but they did not reach bone damage levels, at least under the loads applied in this study. It was concluded that greater stress observed in the GP demonstrates greater fragility with this modality of rehabilitation; this should draw the professional's attention to possible biomechanical implications. Whenever possible, professionals should give preference to use of a greater number of implants in the rehabilitation system, with a focus on preserving the supporting tissue with the generation of less intense stresses.
Collapse
|
47
|
Influence of Different Implants on the Biomechanical Behavior of a Tooth-Implant Fixed Partial Dentures: A Three-Dimensional Finite Element Analysis. J ORAL IMPLANTOL 2020; 46:27-34. [PMID: 31647692 DOI: 10.1563/aaid-joi-d-18-00314] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
This study analyzed the biomechanical behavior of rigid and nonrigid tooth-implant supported fixed partial dentures. Different implants were used to observe the load distribution over teeth, implants, and adjacent bone using three-dimensional finite element analysis. A simulation of tooth loss of the first and second right molars was created with an implant placed in the second right molar and a prepared tooth with simulated periodontal ligament (PDL) in the second right premolar. Configurations of two types of implants and their respective abutments-external hexagon (EX) and Morse taper (MT)-were transformed into a 3D format. Metal-ceramic fixed partial dentures were constructed with rigid and nonrigid connections. Mesh generation and data processing were performed on the 3D finite element analysis (FEA) results. Static loading of 50 N (premolar) and 100 N (implant) were applied. When an EX implant was used, with a rigid or nonrigid connection, there was intrusion of the tooth in the distal direction with flexion of the periodontal ligament. Tooth intrusion did not occur when the MT implant was used independent of a rigid or nonrigid connection. The rigid or nonrigid connection resulted in a higher incidence of compressive forces at the cortical bone as well as stress in the abutment/pontic area, regardless of whether EX or MT implants were used. MT implants have a superior biomechanical performance in tooth-implant supported fixed partial dentures. This prevents intrusion of the tooth independent of the connection. Both types of implants studied caused a greater tendency of compressive forces at the crestal area.
Collapse
|
48
|
In vitro digital image correlation analysis of the strain transferred by screw-retained fixed partial dentures supported by short and conventional implants. J Mech Behav Biomed Mater 2019; 103:103556. [PMID: 31785542 DOI: 10.1016/j.jmbbm.2019.103556] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Revised: 11/22/2019] [Accepted: 11/25/2019] [Indexed: 02/06/2023]
Abstract
PURPOSE This study used digital image correlation (DIC) to evaluate the strain transferred by splinted and non-splinted screw-retained fixed partial dentures (FPDs) supported by short and conventional implants. MATERIAL AND METHODS Four polyurethane models were fabricated to simulate half of the mandibular arch with acrylic resin replicas of the first premolar. Short (5 mm) and/or conventional (11 mm) implants replaced the second premolar and the first and second molars. Groups were: G1, two conventional (second premolar and first molar) and one short (second molar) implant; G2, one conventional (second premolar) and two short (first and second molar) implants; G3, three short implants; and G4, three conventional implants. Splinted (S) and non-splinted (NS) FPDs were screwed to the implant abutments. Occlusal load and a single point load on the second premolar, both of 250 N, were applied. Strain in the horizontal direction (Ɛxx) was calculated and compared using the DIC software. RESULTS Splinted crowns presented the highest strain magnitudes of all tested groups (p < 0.05). The strain was concentrated near the short implants and presented a higher magnitude compared to conventional implants, especially in G2S (-560.13 μS), G3S (-372.97 μS), and G4S (-356.67 μS). CONCLUSIONS Splinted crowns presented a higher strain concentration around the implants, particularly near the implant replacing the first molar. A combination of short and conventional implants seems to be a viable alternative for the rehabilitation of the posterior edentulous mandible with reduced bone height.
Collapse
|
49
|
Caries removal with Er:YAG laser followed by dentin biomodification with carbodiimide and chitosan: Wettability and surface morphology analysis. Microsc Res Tech 2019; 83:133-139. [PMID: 31663194 DOI: 10.1002/jemt.23395] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2019] [Revised: 09/05/2019] [Accepted: 09/19/2019] [Indexed: 11/12/2022]
Abstract
This study aimed to investigate dentin wettability and surface morphology after selective removal of carious lesion by erbium-doped yttrium aluminum garnet (Er:YAG) laser, followed by dentin biomodification with carbodiimide (EDC) and chitosan (CHI). Seventy-eight bovine dentin specimens were submitted to caries induction. Specimens were distributed according to methods of carious removal (n = 39): bur at low-speed (40,000 rpm) or Er:YAG laser (noncontact mode, 250 mJ/pulse and 4Hz). All specimens were etched with 35% phosphoric acid, and subdivided according to dentin biomodification (n = 13): Control (no biomodification), EDC or CHI. The contact angle (n = 10) between adhesive system (3M ESPE) and dentin surface was measured by a goniometer. Eighteen specimens (n = 3) were analyzed by scanning electron microscopy. Data were analyzed by two-way ANOVA and Tukey's test (α = .05). The method used to remove carious lesion did not influence the wettability of dentinal surface (p = .748). The angles produced on the remaining dentin after biomodification were influenced (p = .007). CHI promoted higher contact angles (p = .007) and EDC did not differ from the control group (p = .586). In the bur-treated group, most tubules were open, regardless of which biomodifier was used. Laser modified the organic matrix layer. CHI promoted partially closed tubules in some areas while EDC exposed dentinal tubules. Regardless of which method was used for selective removal of carious lesion, biomodification with EDC did not affect the dentin wettability, whereas CHI changed the wettability of remaining dentin. Both biomodifiers promoted a slight change on dentin morphology.
Collapse
|
50
|
Effects of latex membrane on guided regeneration of long bones. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2019; 30:1291-1307. [DOI: 10.1080/09205063.2019.1627653] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|