1
|
Smartphone-based device for rapid and single-step detection of piRNA-651 using anti-DNA:RNA hybrid antibody and enzymatic signal amplification. Anal Chim Acta 2024; 1305:342583. [PMID: 38677845 DOI: 10.1016/j.aca.2024.342583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 04/01/2024] [Accepted: 04/04/2024] [Indexed: 04/29/2024]
Abstract
P-element-induced wimpy testis (PIWI)-interacting RNAs (piRNAs/piRs) are a class of small noncoding RNAs that play a crucial role in regulating various biological processes, including carcinogenesis. One specific piRNA, piR-651, has been reported to be overexpressed in both human blood serum and solid cancer tissues, that can be used a viable biomarker in cancer diagnosis. Early diagnosis of cancer can help reduce the burden of the disease and improve survival rates. In the present work, we report for the first time a smartphone-based colorimetric biosensor for highly sensitive and specific detection of piR-651 thanks to an enzymatic signal amplification, which yielded high colorimetric intensities. Indeed, a heteroduplex DNA:RNA was formed in the presence of piR-651 with the capture DNA probe immobilized on the magnetic beads for easy magnetic separation. Then, a HRP tethered to anti-DNA:RNA (S9.6) was used to reveal the DNA-RNA heteroduplex formed by catalyzing the oxidation of TMB substrate into colorimetric TMBox, which absorbs at 630 nm. The absorbance is positively proportional to the piR-651 concentrations. On the other hand, the colorimetric product of the assay can be photographed with a smartphone camera and analyzed using ImageJ software. Using a smartphone and under optimal conditions, the biosensor responded linearly to the logarithm of piRNA-651 from 8 fM to 100 pM with a detection limit of 2.3 fM and discriminates against other piRNAs. It was also successfully applied to the determination of piRNA-651 levels in spiked human serum.
Collapse
|
2
|
Innovative approaches to suppress non-specific adsorption in molecularly imprinted polymers for sensing applications. Biosens Bioelectron 2024; 250:116053. [PMID: 38266615 DOI: 10.1016/j.bios.2024.116053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 01/10/2024] [Accepted: 01/18/2024] [Indexed: 01/26/2024]
Abstract
Molecularly imprinted polymers (MIPs) are synthetic antibodies developed to bind selectively with specific molecules. They function through a particular recognition process involving their cavities and functional groups. Nevertheless, functional groups located outside these cavities are the main cause of non-specific molecule binding, thus reducing the effectiveness of MIPs in sensing applications. This work focused on enhancing the selectivity and performance of MIPs through electrostatic modification with surfactants. The study investigates the use of two surfactants, namely sodium dodecyl sulfate (SDS) and cetyl trimethyl ammonium bromide (CTAB), to eliminate non-specific adsorption in MIPs. The binding isotherms of the target molecule sulfamethoxazole (SMX) on MIPs and non-imprinted polymers (NIPs) were analyzed, showing higher adsorption capacity of MIPs due to the specific cavities. The modification with SDS or CTAB effectively eliminated non-specific adsorption in MIPs. The kinetic adsorption behavior further demonstrated the efficacy of MIP+--SDS/CTAB in the selective adsorption of SMX. Calibration curves showcase the methodology's analytical capabilities, achieving low limit of detection for SMX 6 ng mL-1 using MIP +-SDS. The stability study confirmed that the developed MIP +/--SDS/CTAB remains stable even at high temperatures, demonstrating its suitability for on-site applications. The methodology was successfully applied to detect SMX in milk and water samples, achieving promising recoveries. Overall, the electrostatic modification of MIPs with surfactants emerges as a valuable strategy for enhancing selectivity and performance in target molecule recognition and detection.
Collapse
|
3
|
Molecularly imprinted photopolymers combined with smartphone-based optical sensing for selective detection of bisphenol A in foods. Anal Bioanal Chem 2024:10.1007/s00216-024-05212-0. [PMID: 38462592 DOI: 10.1007/s00216-024-05212-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 02/13/2024] [Accepted: 02/19/2024] [Indexed: 03/12/2024]
Abstract
Bisphenol A (BPA), known for its endocrine-disrupting properties and potential to leach into food products, has led to significant food safety concerns. Therefore, the development of sensitive and selective BPA rapid detection methods is crucial. In this study, molecularly imprinted solid-phase extraction coupled to a colorimetric method was adopted for the smartphone-based determination of BPA. The molecularly imprinted polymer (MIP) was prepared via photopolymerization and used as a selective adsorbent material for SPE columns. The solid-phase extraction (SPE) columns with multiple cycles significantly reduced the extraction time to only 30 min. The developed method demonstrates useful sensitivity for BPA (LOD = 30 ppb). Furthermore, BPA migration from plastic packaging was evaluated under different storage conditions, revealing that microwave treatment for 5 min led to BPA release from polycarbonate packaging in juice and basic solutions. The MIP selective extraction/clean-up and smartphone-based optical sensor were successfully applied to BPA standard solutions and complex food samples (e.g., juice and tap water), resulting in reproducible and selective BPA determination (RSD ≤ 6%, n = 3). This rapid and cost-effective method of producing MIPs for BPA offers a promising solution for fast and low-cost sensing for on-site fresh food analysis.
Collapse
|
4
|
Selective extraction of maleic hydrazide in foods using magnetic molecularly imprinted polymers and colorimetric detection via smartphone. Talanta 2024; 269:125488. [PMID: 38071768 DOI: 10.1016/j.talanta.2023.125488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2023] [Revised: 11/18/2023] [Accepted: 11/24/2023] [Indexed: 01/05/2024]
Abstract
Maleic hydrazide (MH) is a plant growth regulator, herbicide, and sprout inhibitor used to improve the growth and quality of certain vegetables and fruits, unfortunately, MH has genotoxic and carcinogenic effects; thus, MH residues in food need to be analyzed. Herein, magnetic molecularly imprinted polymers (MagMIP) were synthesized by radical polymerization in just 30 min using a microwave for rapid and selective extraction of MH. The colorimetric detection of MH using the immobilized Folin Ciocalteau's reagent (FCR) on 96-well microplate via smartphone sensor exhibits useful sensitivity for MH with a limit of detection (LOD = 0.6 ppm) which is far lower than the maximum residue limits (higher than 5 ppm). The immobilized FCR was stored dry at two different storage conditions at +4 °C and room temperature without losing its performance over six months. The coupling MagMIP-extraction/clean-up and smartphone determination were tested towards food samples (i.e., potatoes, and carrots), obtaining good recovery (79-96 %), high repeatability (RSD 4.5 %; n = 10), and high selectivity for MH determination.
Collapse
|
5
|
Development of a molecularly imprinted membrane for selective, high-sensitive, and on-site detection of antibiotics in waters and drugs: Application for sulfamethoxazole. CHEMOSPHERE 2024; 350:141039. [PMID: 38147923 DOI: 10.1016/j.chemosphere.2023.141039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 12/22/2023] [Accepted: 12/23/2023] [Indexed: 12/28/2023]
Abstract
Sulfonamides are among the widespread bacterial antibiotics. Despite this, their quick emergence constitutes a serious problem for ecosystems and human health. Therefore, there is an increased interest in developing relevant detection method for antibiotics in different matrices. In this work, a straightforward, green, and cost-effective protocol was proposed for the preparation of a selective molecularly imprinted membrane (MIM) of sulfamethoxazole (SMX), a commonly used antibiotic. Thus, cellulose acetate was used as the functional polymer, while polyethylene glycol served as a pore-former. The developed MIM was successfully characterized through scanning electron microscopy (SEM), atomic force microscopy (AFM), Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), and thermogravimetric analysis (TGA). The MIM was used as a sensing platform in conjunction with a smartphone for optical readout, enabling on-site, selective, and highly sensitive detection of SMX. In this way, a satisfactory imprinting factor of around 3.6 and a limit of detection of 2 ng mL-1 were reached after applying response surface methodologies, including Box-Behnken and central composite designs. Besides, MIM demonstrated its applicability for the accurate and selective detection of SMX in river waters, wastewater, and drugs. Additionally, the MIM was shown to be a valuable sorbent in a solid-phase extraction protocol, employing a spin column setup that offered rapid and reproducible results. Furthermore, the developed sensing platform exhibited notable regeneration properties over multiple cycles and long shelf-life in different storage conditions. The newly developed methodology is of crucial importance to overcome the limitations of classical imprinting polymers. Furthermore, the smartphone-based platform was used to surpass the typically expensive and complicated methods of detection.
Collapse
|
6
|
A highly sensitive colorimetric DNA sensor for MicroRNA-155 detection: leveraging the peroxidase-like activity of copper nanoparticles in a double amplification strategy. Mikrochim Acta 2023; 191:32. [PMID: 38102528 DOI: 10.1007/s00604-023-06087-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Accepted: 11/06/2023] [Indexed: 12/17/2023]
Abstract
A novel and highly sensitive colorimetric DNA sensor for determination of miRNA-155 at attomolar levelsis presented that combines the peroxidase-like activity of copper nanoparticles (CuNPs) with the hybridization chain reaction (HCR) . The utilization of CuNPs offers advantages such as strong interaction with double-stranded DNA, excellent molecular recognition, and mimic catalytic activity. Herein, a capture probe DNA (P1) was immobilized on carboxylated magnetic beads (MBs), allowing for amplified immobilization due to the 3D surface. Subsequently, the presence of the target microRNA-155 led to the formation of a sandwich structure (P2/microRNA-155/P1/MBs) when P2 was introduced to the modified P1/MBs. The HCR reaction was then triggered by adding H1 and H2 to create a super sandwich (H1/H2)n. Following this, Cu2+ ions were attracted to the negatively charged phosphate groups of the (H1/H2)n and reduced by ascorbic acid, resulting in the formation of CuNPs, which were embedded into the grooves of the (H1/H2)n. The peroxidase-like activity of CuNPs catalyzed the oxidation reaction of 3,3',5,5'-Tetramethylbenzidine (TMB), resulting in a distinct blue color measured at 630 nm. Under optimal conditions, the colorimetric biosensor exhibited a linear response to microRNA-155 concentrations ranging from 80 to 500 aM, with a detection limit of 22 aM, and discriminate against other microRNAs. It was also successfully applied to the determination of microRNA-155 levels in spiked human serum.
Collapse
|
7
|
Fast impedimetric immunosensing of IgGs associated with peanut and hazelnut allergens. Biosens Bioelectron 2023; 242:115612. [PMID: 37804572 DOI: 10.1016/j.bios.2023.115612] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2023] [Revised: 07/22/2023] [Accepted: 08/17/2023] [Indexed: 10/09/2023]
Abstract
Food allergies trigger a variety of clinical adverse symptoms and clinical evidence suggests that the presence of food allergy-related IgG can be helpful in the diagnosis when analyzed at the peptide-epitope level. To validate and select the peptides based on their specificity toward hazelnut or peanut epitopes, the authors of this study developed a silicon-based microchip coupled with click-chemistry bound peptides identified by the Fraunhofer Institute for Cell Therapy and Immunology. Peptides related to hazelnut and peanut allergies were identified and used to develop a silicon-based microchip. Peptides were coupled with click-chemistry to the sensor surface. The immunosensor was developed by electrografting diazotized amino phenylacetic acid and subsequently, dibenzocyclooctyne-amine (DBCO-NH2) was used as click-chemistry to allow coupling of the peptides with a C-terminal linker and azide structure. Energy-dispersive X-ray spectroscopy, electrochemical impedance spectroscopy (EIS), and fluorescence microscopy techniques have been used to analyze the bio-functionalization of the developed electrode. The peptide-epitope recognition was studied for seven allergen-derived peptides. The electrochemical responses were studied with sera from rabbits immunized with hazelnut and peanut powder. The microchips functionalized with the chosen peptides (peanut peptides T12 and EO13 and hazelnut peptides S4 and EO14 with an RSD of 4%, 3%, 9%, and 1% respectively) demonstrated their ability to specifically detect prevalent anti-nut related IgGs in rabbit sera in a range of dilutions from 1:500000 (0.0002%) until 1:50000 (0.002%). In addition, the other peptides showed promising differentiation abilities which can be further studied to perform multivariable detection fingerprint of anti-allergens in blood sera.
Collapse
|
8
|
Exploring the potential of molecularly imprinted polymers and metal/metal oxide nanoparticles in sensors: recent advancements and prospects. Mikrochim Acta 2023; 190:497. [PMID: 38040934 DOI: 10.1007/s00604-023-06030-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 10/04/2023] [Indexed: 12/03/2023]
Abstract
Metal/metal oxide nanoparticles have gained increasing attention in recent years due to their outstanding features, including optical and catalytic properties, as well as their excellent conductivity. The implementation of metal/metal oxide nanoparticles, combined with molecularly imprinted polymers (MIPs) has paved the way for a new generation of building blocks to engineer and enhance the fascinating features of advanced sensors. This review critically evaluates the impact of combining metal/metal oxide nanoparticles with MIPs in sensors. It covers synthesis strategies, advantages of coupling these materials with MIPs, and addresses questions about the selectivity of these hybrid materials. In the end, the current challenges and future perspectives of this field are discussed, with a particular focus on the potential applications of these hybrid composites in the sensor field. This review highlights the exciting opportunities of using metal/metal oxide nanoparticles along with MIPs for the development of next-generation sensors.
Collapse
|
9
|
Untreated vs. Treated Carbon Felt Anodes: Impacts on Power Generation in Microbial Fuel Cells. MICROMACHINES 2023; 14:2142. [PMID: 38138311 PMCID: PMC10744851 DOI: 10.3390/mi14122142] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 11/19/2023] [Accepted: 11/20/2023] [Indexed: 12/24/2023]
Abstract
This research sought to enhance the efficiency and biocompatibility of anodes in bioelectrochemical systems (BESs) such as microbial fuel cells (MFCs), with an aim toward large-scale, real-world applications. The study focused on the effects of acid-heat treatment and chemical modification of three-dimensional porous pristine carbon felt (CF) on power generation. Different treatments were applied to the pristine CF, including coating with carbon nanofibers (CNFs) dispersed using dodecylbenzene sulfonate (SDBS) surfactant and biopolymer chitosan (CS). These processes were expected to improve the hydrophilicity, reduce the internal resistance, and increase the electrochemically active surface area of CF anodes. A high-resolution scanning electron microscopy (HR-SEM) analysis confirmed successful CNF coating. An electrochemical analysis showed improved conductivity and charge transfer toward [Fe(CN)6]3-/4- redox probe with treated anodes. When used in an air cathode single-chamber MFC system, the untreated CF facilitated quicker electroactive biofilm growth and reached a maximum power output density of 3.4 W m-2, with an open-circuit potential of 550 mV. Despite a reduction in charge transfer resistance (Rct) with the treated CF anodes, the power densities remained unchanged. These results suggest that untreated CF anodes could be most promising for enhancing power output in BESs, offering a cost-effective solution for large-scale MFC applications.
Collapse
|
10
|
Selective Sensing in Microbial Fuel Cell Biosensors: Insights from Toxicity-Adapted and Non-Adapted Biofilms for Pb(II) and Neomycin Sulfate Detection. MICROMACHINES 2023; 14:2027. [PMID: 38004884 PMCID: PMC10673119 DOI: 10.3390/mi14112027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 10/25/2023] [Accepted: 10/27/2023] [Indexed: 11/26/2023]
Abstract
This study introduces the utilization of self-powered microbial fuel cell (MFC)-based biosensors for the detection of biotoxicity in wastewater. Current MFC-based biosensors lack specificity in distinguishing between different pollutants. To address this limitation, a novel approach is introduced, capitalizing on the adaptive capabilities of anodic biofilms. By acclimating these biofilms to specific pollutants, an enhancement in the selectivity of MFC biosensors is achieved. Notably, electrochemically active bacteria (EAB) were cultivated on 3D porous carbon felt with and without a model toxicant (target analyte), resulting in the development of toxicant-resistant anodic biofilms. The model toxicants, Pb2+ ions and the antibiotic neomycin sulfate (NS), were deployed at a concentration of 1 mg L-1 during MFC operation. The influence of toxicity on biofilm growth and power production was investigated through polarization and power density curves. Concurrently, the electrochemical activity of both non-adapted and toxicity-adapted biofilms was investigated using cyclic voltammetry. Upon maturation and attainment of peak powers, the MFC reactors were evaluated individually as self-powered biosensors for pollutant detection in fresh wastewater, employing the external resistor (ER) mode. The selected ER, corresponding to the maximum power output, was positioned between the cathode and anode of each MFC, enabling output signal tracking through a data logging system. Subsequent exposure of mature biofilm-based MFC biosensors to various concentrations of the targeted toxicants revealed that non-adapted mature biofilms generated similar current-time profiles for both toxicity models, whereas toxicity-adapted biofilms produced distinctive current-time profiles. Accordingly, these results suggested that merely by adapting the anodic biofilm to the targeted toxicity, distinct and identifiable current-time profiles can be created. Furthermore, these toxicity-adapted and non-adapted biofilms can be employed to selectively detect the pollutant via the differential measurement of electrical signals. This differentiation offers a promising avenue for selective pollutant detection. To the best of our current knowledge, this approach, which harnesses the natural adaptability of biofilms for enhanced sensor selectivity, represents a pioneering effort in the realm of MFC-based biosensing.
Collapse
|
11
|
Unlocking the Potential of Molecularly Imprinted Polydopamine in Sensing Applications. Polymers (Basel) 2023; 15:3712. [PMID: 37765566 PMCID: PMC10536926 DOI: 10.3390/polym15183712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 08/30/2023] [Accepted: 09/07/2023] [Indexed: 09/29/2023] Open
Abstract
Molecularly imprinted polymers (MIPs) are synthetic receptors that mimic the specificity of biological antibody-antigen interactions. By using a "lock and key" process, MIPs selectively bind to target molecules that were used as templates during polymerization. While MIPs are typically prepared using conventional monomers, such as methacrylic acid and acrylamide, contemporary advancements have pivoted towards the functional potential of dopamine as a novel monomer. The overreaching goal of the proposed review is to fully unlock the potential of molecularly imprinted polydopamine (MIPda) within the realm of cutting-edge sensing applications. This review embarks by shedding light on the intricate tapestry of materials harnessed in the meticulous crafting of MIPda, endowing them with tailored properties. Moreover, we will cover the diverse sensing applications of MIPda, including its use in the detection of ions, small molecules, epitopes, proteins, viruses, and bacteria. In addition, the main synthesis methods of MIPda, including self-polymerization and electropolymerization, will be thoroughly examined. Finally, we will examine the challenges and drawbacks associated with this research field, as well as the prospects for future developments. In its entirety, this review stands as a resolute guiding compass, illuminating the path for researchers and connoisseurs alike.
Collapse
|
12
|
Development of an Innovative Colorimetric DNA Biosensor Based on Sugar Measurement. BIOSENSORS 2023; 13:853. [PMID: 37754087 PMCID: PMC10526849 DOI: 10.3390/bios13090853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 08/22/2023] [Accepted: 08/24/2023] [Indexed: 09/28/2023]
Abstract
The development of biosensors for target detection plays a crucial role in advancing various fields of bioscience. This work presents the development of a genosensor that exploits the colorimetric phenol-sulfuric acid sugar reaction for the detection of DNA, and RNA as specific targets, and DNA intercalator molecules. The biosensor combines simplicity and reliability to create a novel bioassay for accurate and rapid analysis. A 96-well microplate based on a polystyrene polymer was used as the platform for an unmodified capture DNA immobilization via a silanization process and with (3-Aminopropyl) triethoxysilane (APTES). After that, a hybridization step was carried out to catch the target molecule, followed by adding phenol and sulfuric acid to quantify the amount of DNA or RNA sugar backbone. This reaction generated a yellow-orange color on the wells measured at 490 nm, which was proportional to the target concentration. Under the optimum conditions, a calibration curve was obtained for each target. The developed biosensor demonstrated high sensitivity, good selectivity, and linear response over a wide concentration range for DNA and RNA targets. Additionally, the biosensor was successfully employed for the detection of DNA intercalator agents that inhibited the hybridization of DNA complementary to the immobilized capture DNA. The developed biosensor offers a potential tool for sensitive and selective detection in various applications, including virus diagnosis, genetic analysis, pathogenic bacteria monitoring, and drug discovery.
Collapse
|
13
|
Magnetic Molecularly Imprinted Chitosan Combined with a Paper-Based Analytical Device for the Smartphone Discrimination of Tryptophan Enantiomers. BIOSENSORS 2023; 13:830. [PMID: 37622916 PMCID: PMC10452675 DOI: 10.3390/bios13080830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2023] [Revised: 08/04/2023] [Accepted: 08/15/2023] [Indexed: 08/26/2023]
Abstract
The separation of enantiomers plays a critical role in pharmaceutical development, ensuring therapeutic efficacy, safety, and patent protection. It enables the production of enantiopure drugs and enhances our understanding of the properties of chiral compounds. In this study, a straightforward and effective chiral detection strategy was developed for distinguishing between tryptophan (TRP) enantiomers. The approach involved the preparation of a magnetic molecularly imprinted chitosan (MMIC) for preparation of the sample, which was combined with a nitrocellulose membrane (a paper-based analytical device, PAD) integrated with D-TRP covalently grafted with polymethacrylic acid (PAD-PMA_D-TRP). Discriminating between the TRP enantiomers was achieved using AuNPs as a colorimetric probe. Indeed, the presence of D-TRP rapidly induced the aggregation of AuNPs due to its strong affinity to PAD-PMA_D-TRP, resulting in a noticeable change in the color of the AuNPs from red to purple. On the other hand, L-TRP did not induce any color changes. The chiral analysis could be easily performed with the naked eye and/or a smartphone. The developed method exhibited a detection limit of 3.3 µM, and it was successfully applied to detect TRP in serum samples, demonstrating good recovery rates. The proposed procedure is characterized by its simplicity, cost-effectiveness, rapidity, and ease of operation.
Collapse
|
14
|
Immobilization of diphenylcarbazide on paper-based analytical devices for the pre-concentration and detection of chromium VI in water samples. Talanta 2023; 265:124889. [PMID: 37399649 DOI: 10.1016/j.talanta.2023.124889] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 06/20/2023] [Accepted: 06/27/2023] [Indexed: 07/05/2023]
Abstract
A novel approach using a smartphone for the detection of Cr (VI) has been developed. In this context, two different platforms were designed for the detection of Cr (VI). The first one was synthesized via a crosslinking reaction of chitosan with 1,5-Diphenylcarbazide (DPC-CS). The obtained material was integrated into a paper to develop a new paper-based analytical device (DPC-CS-PAD). The DPC-CS-PAD exhibited high specificity toward Cr (VI). The second platform (DPC-Nylon PAD) was prepared by covalent immobilization of DPC onto a Nylon paper and then its analytical performances regarding Cr (VI) extraction and detection were evaluated. DPC-CS-PAD presented a linear range of 0.1-5 ppm with detection and quantification limits of about 0.04 and 0.12 ppm, respectively. The DPC-Nylon-PAD exhibited a linear response of 0.1-2.5 ppm with detection and quantification limits of 0.06 and 0.2 ppm, respectively. Furthermore, the developed platforms were effectively applied for testing the effect of the loading solution volume for trace Cr (IV) detection. For the DPC-CS material, a volume of 20 mL allowed the detection of 4 ppb of Cr (VI). In the case of DPC-Nylon-PAD, the loading volume of 1 mL permitted the detection of the critical concentration of Cr (VI) in water.
Collapse
|
15
|
Feather-like Gold Nanostructures Anchored onto 3D Mesoporous Laser-Scribed Graphene: A Highly Sensitive Platform for Enzymeless Glucose Electrochemical Detection in Neutral Media. BIOSENSORS 2023; 13:678. [PMID: 37504077 PMCID: PMC10377420 DOI: 10.3390/bios13070678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 06/16/2023] [Accepted: 06/21/2023] [Indexed: 07/29/2023]
Abstract
The authors present a novel sensing platform for a disposable electrochemical, non-enzymatic glucose sensor strip at physiological pH. The sensing material is based on dendritic gold nanostructures (AuNs) resembling feather branches, which are electrodeposited onto a laser-scribed 3D graphene electrode (LSGE). The LSGEs were fabricated via a one-step laser scribing process on a commercially available polyimide sheet. This study investigates several parameters that influence the morphology of the deposited Au nanostructures and the catalytic activity toward glucose electro-oxidation. The electrocatalytic activity of the AuNs-LSGE was evaluated using cyclic voltammetry (CV), linear sweep voltammetry (LSV), and amperometry and was compared to commercially available carbon electrodes prepared under the same electrodeposition conditions. The sensor demonstrated good stability and high selectivity of the amperometric response in the presence of interfering agents, such as ascorbic acid, when a Nafion membrane was applied over the electrode surface. The proposed sensing strategy offers a wide linear detection range, from 0.5 to 20 mM, which covers normal and elevated levels of glucose in the blood, with a detection limit of 0.21 mM. The AuNs-LSGE platform exhibits great potential for use as a disposable glucose sensor strip for point-of-care applications, including self-monitoring and food management. Its non-enzymatic features reduce dependence on enzymes, making it suitable for practical and cost-effective biosensing solutions.
Collapse
|
16
|
Geographical Classification of Saffron ( Crocus Sativus L.) Using Total and Synchronous Fluorescence Combined with Chemometric Approaches. Foods 2023; 12:foods12091747. [PMID: 37174286 PMCID: PMC10178536 DOI: 10.3390/foods12091747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2023] [Revised: 04/12/2023] [Accepted: 04/14/2023] [Indexed: 05/15/2023] Open
Abstract
There is an increasing interest in food science for high-quality natural products with a distinct geographical origin, such as saffron. In this work, the excitation-emission matrix (EEM) and synchronous fluorescence were used for the first time to geographically discriminate between Moroccan saffron from Taroudant, Ouarzazate, and Azilal. Moreover, to differentiate between Afghan, Iranian, and Moroccan saffron, a unique fingerprint was assigned to each sample by visualizing the EEM physiognomy. Moreover, principal component analysis (LDA) and linear discriminant analysis (LDA) were successfully applied to classify the synchronous spectra of samples. High fluorescence intensities were registered for Ouarzazate and Taroudant saffron. Yet, the Azilal saffron was distinguished by its low intensities. Furthermore, Moroccan, Afghan, and Iranian saffron were correctly assigned to their origins using PCA and LDA for different offsets (Δλ) (20-250 nm) such that the difference in the fluorescence composition of the three countries' saffron was registered in the following excitation/emission ranges: 250-325 nm/300-480 nm and 360-425 nm/500-550 nm. These regions are characterized by the high polyphenolic content of Moroccan saffron and the important composition of Afghan saffron, including vitamins and terpenoids. However, weak intensities of these compounds were found in Iranian saffron. Furthermore, a substantial explained variance (97-100% for PC1 and PC2) and an important classification rate (70-90%) were achieved. Thus, the non-destructive applied methodology of discrimination was rapid, straightforward, reliable, and accurate.
Collapse
|
17
|
Development of a New Route for the Immobilization of Unmodified Single-Stranded DNA on Chitosan Beads and Detection of Released Guanine after Hydrolysis. Molecules 2023; 28:molecules28052088. [PMID: 36903335 PMCID: PMC10004340 DOI: 10.3390/molecules28052088] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 02/14/2023] [Accepted: 02/21/2023] [Indexed: 02/25/2023] Open
Abstract
In this work, chitosan beads were used as a cost-effective platform for the covalent immobilization of unmodified single-stranded DNA, using glutaraldehyde as a cross-linking agent. The immobilized DNA capture probe was hybridized in the presence of miRNA-222 as a complementary sequence. The target was evaluated based on the electrochemical response of the released guanine, using hydrochloride acid as a hydrolysis agent. Differential pulse voltammetry technique and screen-printed electrodes modified with COOH-functionalized carbon black were used to monitor the released guanine response before and after hybridization. The functionalized carbon black provided an important signal amplification of guanine compared to the other studied nanomaterials. Under optimal conditions (6 M HCl at 65 °C for 90 min), an electrochemical-based label-free genosensor assay exhibited a linear range between 1 nM and 1 µM of miRNA-222, with a detection limit of 0.2 nM of miRNA-222. The developed sensor was successfully used to quantify miRNA-222 in a human serum sample.
Collapse
|
18
|
Paper-based optical sensors paired with smartphones for biomedical analysis. J Pharm Biomed Anal 2023; 225:115207. [PMID: 36584551 DOI: 10.1016/j.jpba.2022.115207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 12/07/2022] [Accepted: 12/16/2022] [Indexed: 12/24/2022]
Abstract
The traditional analytical methods used for biomedical analysis are expensive and not easy to handle and require sophisticated instruments, thus their application is limited in resource-limited settings. Due to their portability, low cost, and ability to be applied to different analytical techniques, paper-based analytical devices are becoming valuable tools for biomedical analysis. The integration of smartphones into analytical devices has provided the ability to build portable, cost-effective, straightforward analytical devices for biomedical analysis and mobile health. The key aim of this review is to emphasize the recent applications of PADs combined with a smartphone for the optical analysis of biomedical species. We started this review by highlighting the type of papers and their modifications with different materials to prepare the PADs. After that, this review presents various detection methods including colorimetry, fluorescence, and luminescence where the smartphone is used for read-out. In the end, we provided the recent applications of the analysis of different biomedical compounds such as cancer and cardiovascular biomarkers, metal ions, glucose, viruses, etc. We believe that the present review will attract a wide scientific community in the areas of analytical chemistry, sensors, and clinical testing.
Collapse
|
19
|
Liquid-phase exfoliated 2D graphene nanoflakes electrochemical sensor coupled to molecularly imprinted polymers for the determination of citrinin in food. Talanta 2023. [DOI: 10.1016/j.talanta.2022.124010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
20
|
Paper-Based Colorimetric Detection of miRNA-21 Using Pre-Activated Nylon Membrane and Peroxidase-Mimetic Activity of Cysteamine-Capped Gold Nanoparticles. BIOSENSORS 2023; 13:74. [PMID: 36671909 PMCID: PMC9855695 DOI: 10.3390/bios13010074] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2022] [Revised: 12/24/2022] [Accepted: 12/28/2022] [Indexed: 06/17/2023]
Abstract
Irregular expression of MicroRNA-21 (miRNA-21) is considered as a promising biomarker for early cancer diagnosis. In this paper, a new genosensor based on paper and nanozyme activity of cysteamine-capped gold nanoparticles (Cys/AuNPs) was developed to detect picomolar concentrations of miRNA-21. Such nanozyme catalyzes the colorimetric reaction of hydrogen peroxide (H2O2) and 3,3',5,5' tetramethylbenzidine (TMB), to produce a blue color measurable by a smartphone. Due to their positive charge, Cys/AuNPs were attached to the negative phosphate groups of the DNA strand backbone via electrostatic interactions, leading to the quantitative determination of miRNA-21 concentration by the peroxidase-like activity of Cys/AuNPs. Furthermore, a paper-based assay was carried out on nylon disk devices to allow fast immobilization of DNAprobe. After performing the paper-based assay, a good linear range was observed between 1 pM and 1 nM (Y = 0.080 [MiRNA-21]/pM + 13.846, R2 = 0.993) with a detection limit of 0.5 pM. The developed method was effective, selective, and sensitive for the miRNA-21 detection. The application of the proposed method for miRNA-21 detection was examined in a human serum sample, and a recovery rate of 90.0-97.6% was obtained showing the acceptable accuracy of the developed approach.
Collapse
|
21
|
Electrochemical DNA Biosensor Based on Immobilization of a Non-Modified ssDNA Using Phosphoramidate-Bonding Strategy and Pencil Graphite Electrode Modified with AuNPs/CB and Self-Assembled Cysteamine Monolayer. SENSORS (BASEL, SWITZERLAND) 2022; 22:9420. [PMID: 36502122 PMCID: PMC9736659 DOI: 10.3390/s22239420] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/02/2022] [Revised: 11/19/2022] [Accepted: 11/30/2022] [Indexed: 06/17/2023]
Abstract
The present paper describes an alternative approach to the traditionally used covalent immobilization methods that require cost-intensive and complicated chemistry modification of a single-stranded DNA (ssDNA) capture probe. The low-cost pencil graphite electrode (PGE) modified with carbon black (CB) and gold nanoparticles (AuNPs) was used as an electrochemical platform and the non-modified ssDNA was immobilized on a self-assembled cysteamine modified AuNPs/CB-PGE through a phosphoramidate bond between the 5'-terminal phosphate group of ssDNA and the primary amine group of cysteamine. The microRNA-21 was used as a target model in the fabrication of this electrochemical DNA biosensor and the hybridization process with the complementary probe was monitored by differential pulse voltammetry using methylene blue (MB) as an electrochemical hybridization indicator. The decreased reduction peak current of MB shows a good linear correlation with the increased concentration of microRNA-21 target sequences because the MB signal is determined by the amount of exposed guanine bases. The linear range of the fabricated DNA biosensor was from 1.0 × 10-8 to 5.0 × 10-7 M with a detection limit of 1.0 × 10-9 M. These results show that the covalent immobilization of a non-modified ssDNA capture probe through a phosphoramidate-bonding strategy could serve as a cost-effective and versatile approach for the fabrication of DNA biosensors related to a wide range of applications that cover the fields of medical diagnostic and environmental monitoring. The fabricated electrochemical DNA biosensor was used to analyze microRNA-21 in a (spiked) human serum sample and it showed satisfactory and encouraging results as an electrochemical DNA biosensor platform.
Collapse
|
22
|
Green Synthesis of Molecularly Imprinted Polymers for Dispersive Magnetic Solid-Phase Extraction of Erythrosine B Associated with Smartphone Detection in Food Samples. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7653. [PMID: 36363243 PMCID: PMC9655850 DOI: 10.3390/ma15217653] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 10/25/2022] [Accepted: 10/26/2022] [Indexed: 06/16/2023]
Abstract
Monitoring synthetic colorants in foods is important due to their potential toxicity and pathogenicity. We propose here a new and simple method for the extraction and determination of erythrosine B (ERT-B) in food samples. A composite of polydopamine-based molecularly imprinted polymers coating magnetic nanoparticles (Fe3O4@PDA@MIP) was synthesized using a green approach and exploited for the magnetic dispersive solid-phase extraction (MDSPE) of ERT-B. Fe3O4@PDA@MIP provides a rapid extraction of ERT-B, exhibiting good reusability and preconcentration ability. Moreover, the MIP showed a relatively good imprinting factor (3.0 ± 0.05), demonstrating excellent selectivity against patent blue (an interfering dye) and other food matrix components. The proposed MDSPE was coupled to colorimetric smartphone-based detection that allowed us to obtain similar performances of UV-Vis spectroscopy detection. The smartphone-based optical detection facilitated the determination of ERT-B in the 0.5-10 mg/L range, with a limit of detection of 0.04 mg/L. The developed method was successfully employed to determine ERT-B in food samples (juice, candy, and candied cherries) with good recovery values (82-97%).
Collapse
|
23
|
Metal-Organic Frameworks Meet Molecularly Imprinted Polymers: Insights and Prospects for Sensor Applications. ACS APPLIED MATERIALS & INTERFACES 2022; 14:49399-49424. [PMID: 36315467 PMCID: PMC9650679 DOI: 10.1021/acsami.2c12842] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Accepted: 10/06/2022] [Indexed: 05/12/2023]
Abstract
The use of porous materials as the core for synthesizing molecularly imprinted polymers (MIPs) adds significant value to the resulting sensing system. This review covers in detail the current progress and achievements regarding the synergistic combination of MIPs and porous materials, namely metal/covalent-organic frameworks (MOFs/COFs), including the application of such frameworks in the development of upgraded sensor platforms. The different processes involved in the synthesis of MOF/COF-MIPs are outlined, along with their intrinsic properties. Special attention is paid to debriefing the impact of the morphological changes that occur through the synergistic combination compared to those that occur due to the individual entities. Thereafter, the strategies used for building the sensors, as well as the transduction modes, are overviewed and discussed. This is followed by a full description of research advances for various types of MOF/COF-MIP-based (bio)sensors and their applications in the fields of environmental monitoring, food safety, and pharmaceutical analysis. Finally, the challenges/drawbacks, as well as the prospects of this research field, are discussed in detail.
Collapse
|
24
|
Electrochemical Sensing of Paracetamol Using 3D Porous Laser Scribed Graphene Platform. ELECTROANAL 2022. [DOI: 10.1002/elan.202200137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
25
|
Fast sonochemical molecularly imprinted polymer synthesis for selective electrochemical determination of maleic hydrazide. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107634] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
26
|
3D-porous laser-scribed graphene decorated with overoxidized polypyrrole as an electrochemical sensing platform for dopamine. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
27
|
Novel Label-free Colorimetric and Electrochemical Detection for MiRNA-21 Based on the Complexation of Molybdate with Phosphate. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
28
|
A Proof-of-Concept Electrochemical Cytosensor Based on Chlamydomonas reinhardtii Functionalized Carbon Black Screen-Printed Electrodes: Detection of Escherichia coli in Wastewater as a Case Study. BIOSENSORS 2022; 12:bios12060401. [PMID: 35735549 PMCID: PMC9221097 DOI: 10.3390/bios12060401] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 06/07/2022] [Accepted: 06/08/2022] [Indexed: 05/30/2023]
Abstract
Herein, we report a proof-of-concept algal cytosensor for the electrochemical quantification of bacteria in wastewater, exploiting the green photosynthetic alga Chlamydomonas reinhardtii immobilized on carbon black (CB) nanomodified screen-printed electrodes. The CB nanoparticles are used as nanomodifiers, as they are able to sense the oxygen produced by the algae and thus the current increases when algae are exposed to increasing concentrations of bacteria. The sensor was tested on both standard solutions and real wastewater samples for the detection Escherichia coli in a linear range of response from 100 to 2000 CFU/100 mL, showing a limit of detection of 92 CFU/100 mL, in agreement with the maximum E. coli concentration established by the Italian law for wastewater (less than 5000 CFU/100 mL). This bacterium was exploited as a case study target of the algal cytosensor to demonstrate its ability as an early warning analytical system to signal heavy loads of pathogens in waters leaving the wastewater treatment plants. Indeed, the cytosensor is not selective towards E. coli but it is capable of sensing all the bacteria that induce the algae oxygen evolution by exploiting the effect of their interaction. Other known toxicants, commonly present in wastewater, were also analyzed to test the cytosensor selectivity, with any significant effect, apart from atrazine, which is a specific target of the D1 protein of the Chlamydomonas photosystem II. However, the latter can also be detected by chlorophyll fluorescence simultaneously to the amperometric measurements. The matrix effect was evaluated, and the recovery values were calculated as 105 ± 8, 83 ± 7, and 88 ± 7% for 1000 CFU/100 mL of E. coli in Lignano, San Giorgio, and Pescara wastewater samples, respectively.
Collapse
|
29
|
An Ultrasensitive and Selective Determination of Cadmium Ions at ppt Level Using an Enzymic Membrane with Colorimetric and Electrochemical Detection. BIOSENSORS 2022; 12:bios12050310. [PMID: 35624611 PMCID: PMC9138971 DOI: 10.3390/bios12050310] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 04/30/2022] [Accepted: 05/04/2022] [Indexed: 01/17/2023]
Abstract
Cadmium ions (Cd2+) are extremely toxic heavy metal pollutants found in the environment, and which endanger human health. Therefore, it is critical to develop a sensitive and simple method for rapidly detecting Cd2+ in water samples. Herein, an enzymic membrane was developed based on an easy and rapid immobilization method of horseradish peroxidase (HRP), for determination of Cd2+ in drinking water. Hence, for the first time, an enzymic membrane was applied for the detection of Cd2+ without being pretreated. In the first format, the inhibition of horseradish peroxidase was performed using a colorimetric microplate reader. Under optimal conditions, the achieved limit of detection was 20 ppt. In addition, an electrochemical biosensor was developed, by combining the enzymic membrane with screen printed electrodes, which showed a linear calibration range between 0.02–100 ppb (R2 = 0.990) and a detection limit of 50 ppt. The use of this enzymic membrane proved to be advantageous when reversible inhibitors such as the copper ion (Cu2+) were present in water samples, as Cu2+ can interfere with Cd2+ and cause erroneous results. In order to alleviate this problem, a medium exchange procedure was used to eliminate Cu2+, by washing and leaving only cadmium ions as an irreversible inhibitor for identification. The use of this membrane proved to be a simple and rapid method of immobilizing HRP with a covalent bond.
Collapse
|
30
|
Development of a Novel Electrochemical Sensor Based on Functionalized Carbon Black for the Detection of Guanine Released from DNA Hydrolysis. ELECTROANAL 2022. [DOI: 10.1002/elan.202100613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
31
|
Key advances in MIP-based sensors applied for cancer and cardiovascular biomarkers detection. Curr Top Med Chem 2022; 22:529-548. [PMID: 35255794 DOI: 10.2174/1568026622666220307124003] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 12/27/2021] [Accepted: 01/30/2022] [Indexed: 11/22/2022]
Abstract
Cancer and cardiovascular diseases have become one of the leading causes of death worldwide. Therefore, early detection of these diseases and rapid intervention by medical staff remain a great challenge for clinicians and healthcare providers worldwide. Cancer and cardiovascular disease biomarkers are promising tools for early diagnosis of the disease before it becomes incurable at an advanced stage. They also contribute to monitoring the progress of therapy and surgical treatment. Indeed, sensors have shown great importance for the detection of cancer and cardiovascular biomarkers. Sensors usually require a recognition element for the selective detection of targets. Molecularly imprinted polymer (MIP), as an artificial antibody, has been proposed as an alternative recognition element in sensing fields to overcome the main drawbacks of natural antibodies. With the high need for sensors providing results in a short time and making easier the early diagnosis of these diseases, MIP-based sensors are attracting considerable interest recently, which will undoubtedly be increased in the future due to the sustainability trend. The key aim of this review is to emphasize the recent applications of sensors based on MIP for the detection of cancer and cardiovascular biomarkers and to highlight the key advances related to MIP-based sensors. Furthermore, several key future trends about the applications of MIP-based sensors for the detection of cardiovascular and cancer biomarkers are presented.
Collapse
|
32
|
A novel magnetic molecularly imprinted polymer for selective extraction and determination of quercetin in plant samples. Anal Chim Acta 2022; 1203:339709. [DOI: 10.1016/j.aca.2022.339709] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 03/07/2022] [Accepted: 03/08/2022] [Indexed: 02/07/2023]
|
33
|
Development of a simplified spectrophotometric method for nitrite determination in water samples. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 267:120574. [PMID: 34772633 DOI: 10.1016/j.saa.2021.120574] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 10/20/2021] [Accepted: 10/29/2021] [Indexed: 06/13/2023]
Abstract
A new eco-friendly, rapid, and sensitive spectrophotometric method was developed to determine small quantities of nitrite, based on a diazotization mechanism. In an acidic solution, sulfathiazole was first diazotized with sodium nitrite, followed by adding phosphate buffer to form a yellow-colored compound, which showed maximum absorption at 450 nm, without the need for the addition of coupling agents such as N-(1-naphthyl) ethylenediamine. The effects of reagents amount and the optimal experimental conditions were examined by Central composite design. The simplified method presented a wide linear range of nitrite between 0.091 μg mL-1 and 1.47 μg mL-1, a sensitivity of 0.447 Abs mL µg-1, a determination coefficient of 0.998, and a low limit of detection of 0.053 μg mL-1. The simplified method was found to be comparable to the Griess method. It was evaluated for the measurements of nitrite using the accuracy profile approach. The validation procedure results established that 80% of the future results would be within the acceptability limit of 10% over the validation domain ranging from 0.174 μg mL-1 to 1.37 μg mL-1. The developed method was furtherly applied in the determination of nitrite using a developed paper-based analytical device that detected a nitrite concentration of 3 μg mL-1 which is considered by the World Health Organization to be the maximal permissible limit of nitrite in drinking water.
Collapse
|
34
|
Editorial: Rising Stars: Africa. Front Chem 2022; 10:851125. [PMID: 35155375 PMCID: PMC8828965 DOI: 10.3389/fchem.2022.851125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2022] [Accepted: 01/11/2022] [Indexed: 11/13/2022] Open
|
35
|
Highly selective and sensitive detection of cadmium ions by horseradish peroxidase enzyme inhibition using a colorimetric microplate reader and smartphone paper-based analytical device. Microchem J 2022. [DOI: 10.1016/j.microc.2021.106940] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
|
36
|
Enzyme inhibition coupled to molecularly imprinted polymers for acetazolamide determination in biological samples. Talanta 2021; 240:123195. [PMID: 34990987 DOI: 10.1016/j.talanta.2021.123195] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 12/27/2021] [Accepted: 12/28/2021] [Indexed: 11/17/2022]
Abstract
Several methods involving molecularly imprinted polymers (MIPs) devoted to extracting and analyzing sulfonamides from different matrices are reported in literature; however, the unresolved analytical issue is obtaining intra-class selectivity between sulfonamides. Here is presented for the first time a method coupling MIPs and enzymatic inhibition assay for the sensitive and selective determination of acetazolamide (ACZ) in biological samples. The MIPs were synthesized by thermal initiated polymerization in acetone, using acrylamide as functional monomer, ethylene glycol dimethacrylate as cross-linker and ACZ as template molecule. The developed MIPs/enzymatic inhibition based rapid colorimetric method was applied for the determination of ACZ in biological samples. The MIPs were used as sorbent phase in dispersive solid-phase extraction (MIPs-dSPE), and the optimal working parameters were selected. Liquid chromatography-tandam mass spectrometry (LC-MS/MS) analysis confirmed the MIPs ability to extract ACZ. Finally, to obtain a selective and sensitive method, the MIPs-dSPE was combined with an enzymatic inhibition colorimetric assay based on the carbonic anhydrase, an enzyme inhibited by specific sulfonamides. The developed combined method allowed the determination of ACZ in serum, blood and Diamox (a drug containing ACZ), with good recovery (85-96%). Furthermore, a significant correlation with LC-MS/MS analysis was achieved, with relative error ≤15%. In the proposed strategy, the double selectivity giving by MIPs and enzymatic inhibition allowed to obtain a method able to determine selectively ACZ in biological and pharmaceutical samples quantitatively.
Collapse
|
37
|
The Kinetic and Analytical Aspects of Enzyme Competitive Inhibition: Sensing of Tyrosinase Inhibitors. BIOSENSORS 2021; 11:322. [PMID: 34562912 PMCID: PMC8471001 DOI: 10.3390/bios11090322] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 08/27/2021] [Accepted: 09/02/2021] [Indexed: 11/17/2022]
Abstract
An amperometric biosensor based on tyrosinase, immobilized onto a carbon black paste electrode using glutaraldehyde and BSA was constructed to detect competitive inhibitors. Three inhibitors were used in this study: benzoic acid, sodium azide, and kojic acid, and the obtained values for fifty percent of inhibition (IC50) were 119 µM, 1480 µM, and 30 µM, respectively. The type of inhibition can also be determined from the curve of the degree of inhibition by considering the shift of the inhibition curves. Amperometric experiments were performed with a biosensor polarized at the potential -0.15 V vs. Ag/AgCl and using 0.1 M phosphate buffer (pH 6.8) as an electrolyte. Under optimized conditions, the proposed biosensor showed a linear amperometric response toward catechol detection from 0.5 µM to 38 µM with a detection limit of 0.35 µM (S/N = 3), and its sensitivity was 66.5 mA M-1 cm-2. Moreover, the biosensor exhibited a good storage stability. Conversely, a novel graphical plot for the determination of reversible competitive inhibition was represented for free tyrosinase. The graph consisted of plotting the half-time reaction (t1/2) as a function of the inhibitor concentration at various substrate concentrations. This innovative method relevance was demonstrated in the case of kojic acid using a colorimetric bioassay relying on tyrosinase inhibition. The results showed that the t1/2 provides an extended linear range of tyrosinase inhibitors.
Collapse
|
38
|
Smartphone-based competitive immunoassay for quantitative on-site detection of meat adulteration. Talanta 2021; 230:122346. [PMID: 33934795 DOI: 10.1016/j.talanta.2021.122346] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Revised: 03/16/2021] [Accepted: 03/17/2021] [Indexed: 01/15/2023]
Abstract
Rapid, sensitive, and portable analytical methods for on-site inspection of food fraud are now an urgent requirement to ensure food quality and satisfy the ethnic considerations of consumers. Hence, for the first time, a colorimetric smartphone-based immunoassay was developed for the on-site detection of pork adulteration in meat. In detail, the immunoassay was based on a competitive strategy in which immobilized standard porcine IgG competed with the target porcine IgG extracted in a single step from meat samples. The parameters involved in each step of the immunoassay conception and the digital colorimetric detection were carefully investigated and optimized. Using polystyrene microplates as ready-to-use stable and portable immunoplatforms, TMB as chromogenic substrate, smartphone as signal readout, and Image J software for image processing; the developed immunoassay was able to detect as low as 0.01% of pork in meat mixtures in a total assay time of 30 min. The selectivity of the immunoassay was evaluated for different meat species, and it was shown to selectively respond only to pork. Furthermore, excellent stability of the prepared immunological platform was demonstrated under extreme temperature conditions (50 °C), which confirms its high portability potential for in situ quantification of pork, while being relatively cost effective and non-laborious. The developed method also provides great precision (RSD < 6%) and accuracy (relative error< 6%). Given the universal use of smartphones as portable and affordable devices, such format of immunoassay could be a promising approach for rapid and sensitive real-time monitoring of food fraud.
Collapse
|
39
|
Screening study of enzymatic inhibition of medicinal plants for the treatment of diabetes using a glucometer biosensor approach and optical method. J Herb Med 2021. [DOI: 10.1016/j.hermed.2021.100441] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
40
|
Molecularly Imprinted Polymers Combined with Electrochemical Sensors for Food Contaminants Analysis. Molecules 2021; 26:4607. [PMID: 34361757 PMCID: PMC8347609 DOI: 10.3390/molecules26154607] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 07/22/2021] [Accepted: 07/26/2021] [Indexed: 12/18/2022] Open
Abstract
Detection of relevant contaminants using screening approaches is a key issue to ensure food safety and respect for the regulatory limits established. Electrochemical sensors present several advantages such as rapidity; ease of use; possibility of on-site analysis and low cost. The lack of selectivity for electrochemical sensors working in complex samples as food may be overcome by coupling them with molecularly imprinted polymers (MIPs). MIPs are synthetic materials that mimic biological receptors and are produced by the polymerization of functional monomers in presence of a target analyte. This paper critically reviews and discusses the recent progress in MIP-based electrochemical sensors for food safety. A brief introduction on MIPs and electrochemical sensors is given; followed by a discussion of the recent achievements for various MIPs-based electrochemical sensors for food contaminants analysis. Both electropolymerization and chemical synthesis of MIP-based electrochemical sensing are discussed as well as the relevant applications of MIPs used in sample preparation and then coupled to electrochemical analysis. Future perspectives and challenges have been eventually given.
Collapse
|
41
|
An ELIME assay for hepatitis A virus detection. Talanta 2021; 234:122672. [PMID: 34364473 DOI: 10.1016/j.talanta.2021.122672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 06/24/2021] [Accepted: 06/26/2021] [Indexed: 10/20/2022]
Abstract
An Enzyme Linked ImmunoMagnetic Electrochemical assay (ELIME) was developed for the detection of the hepatitis A virus (HAV). This system is based on the use of new polydopamine-modified magnetic nanobeads as solid support for the immunochemical chain, and an array of 8 screen-printed electrodes as a sensing platform. Enzymatic-by-product is quickly measured by differential pulse voltammetry. For this purpose, all analytical parameters were optimized; in particular, different blocking reagents were evaluated in order to minimize the nonspecific interaction of bioreagents. Using the ELIME assays, a quantitative determination of HAV can be achieved with a detection limit of 1·10-11 IU mL-1 and a working range between 10-10 - 5 × 10-7 IU mL-1. The cross-reactivity of the commercial monoclonal antibodies against HAV used in ELIME assays was tested for Coxsackie B4, resulting very low. The sensitivity was also investigated and compared with spectrophotometric sandwich ELISA. The average relative standard deviation (RSD) of the ELIME method was less than 5% for the assays performed on the same day, and 7% for the measurements made on different days. The proposed system was applied to the cell culture of HAV, which title was quantified by Real-Time Quantitative Reverse Transcription PCR (RT¬qPCR). To compare the results, a correlation between the units used in ELIME (IU mL-1) and those used in RT¬qPCR (genome mL-1) was established using a HAV-positive sample, resulting in 1 IU mL-1-10-4 gen mL-1 (R2 = 0.978). The ELIME tool exhibits good stability and high biological selectivity for HAV antigen detection and was successfully applied for the determination of HAV in tap water.
Collapse
|
42
|
A dual electro-optical biosensor based on Chlamydomonas reinhardtii immobilised on paper-based nanomodified screen-printed electrodes for herbicide monitoring. J Nanobiotechnology 2021; 19:145. [PMID: 34001124 PMCID: PMC8130446 DOI: 10.1186/s12951-021-00887-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Accepted: 05/07/2021] [Indexed: 11/24/2022] Open
Abstract
The indiscriminate use of herbicides in agriculture contributes to soil and water pollution, with important endangering consequences on the ecosystems. Among the available analytical systems, algal biosensors have demonstrated to be valid tools thanks to their high sensitivity, cost-effectiveness, and eco-design. Herein, we report the development of a dual electro-optical biosensor for herbicide monitoring, based on Chlamydomonas reinhardtii whole cells immobilised on paper-based screen-printed electrodes modified with carbon black nanomaterials. To this aim, a systematic study was performed for the selection and characterisation of a collection among 28 different genetic variants of the alga with difference response behaviour towards diverse herbicide classes. Thus, CC125 strain was exploited as case study for the study of the analytical parameters. The biosensor was tested in standard solutions and real samples, providing high sensitivity (detection limit in the pico/nanomolar), high repeatability (RSD of 5% with n = 100), long lasting working (10 h) and storage stability (3 weeks), any interference in the presence of heavy metals and insecticides, and low matrix effect in drinking water and moderate effect in surface one.
![]()
Collapse
|
43
|
|
44
|
Fast microwave-assisted synthesis of magnetic molecularly imprinted polymer for sulfamethoxazole. Talanta 2021; 232:122430. [PMID: 34074416 DOI: 10.1016/j.talanta.2021.122430] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2021] [Revised: 04/05/2021] [Accepted: 04/10/2021] [Indexed: 12/16/2022]
Abstract
A fast and simple strategy based on the microwave technique for the preparation of magnetic molecularly imprinted polymers (MMIPs) is proposed for the selective determination of sulfamethoxazole (SMX). The MMIPs were synthesized at 70 °C in 20 min, being much faster than the conventional techniques. A computational approach based on density functional theory was used to design the MMIP and compare the two most used monomers in MIPs, including methacrylic acid (MAA) and acrylamide (AM). Then, two different MMIPs were prepared using AM and MAA as monomers. The resultant materials were characterized with X-ray diffraction, thermogravimetric analysis, scanning/transmission electron microscopy, and Fourier-transform infrared spectroscopy. Besides, the adsorption characterizations suggested that the adsorption of SMX followed the pseudo-second-order model in the kinetic study and the Sips model in the isotherm study. The experimental results corroborated the computational approach. Furthermore, Both MMIPs demonstrated good selectivity. The MMIP-AM and MMIP-MAA were applied as adsorbents in magnetic dispersive solid-phase extraction combined with UV-visible spectroscopy to quantify SMX. The obtained limits of detection and quantification were lower than 0.59 and 1.77 μM, respectively for both MMIPs. The sensitivity of both MMIPs was in the range of 0.021-0.023 (SI). Our findings revealed that there is no significant difference in the analytical parameters between MMIP-AM and MMIP-MAA. However, the application of both MMIPs in a real sample (tap water) showed that the recovery values of SMX obtained with MMIP-AM (68-70%) were lower than that with MMIP-MAA (80-90%) suggesting that MMIP-MAA is more appropriate for SMX determination.
Collapse
|
45
|
Electrochemical Biosensors for Detection of MicroRNA as a Cancer Biomarker: Pros and Cons. BIOSENSORS 2020; 10:E186. [PMID: 33233700 PMCID: PMC7699780 DOI: 10.3390/bios10110186] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/26/2020] [Revised: 11/16/2020] [Accepted: 11/18/2020] [Indexed: 12/23/2022]
Abstract
Cancer is the second most fatal disease in the world and an early diagnosis is important for a successful treatment. Thus, it is necessary to develop fast, sensitive, simple, and inexpensive analytical tools for cancer biomarker detection. MicroRNA (miRNA) is an RNA cancer biomarker where the expression level in body fluid is strongly correlated to cancer. Various biosensors involving the detection of miRNA for cancer diagnosis were developed. The present review offers a comprehensive overview of the recent developments in electrochemical biosensor for miRNA cancer marker detection from 2015 to 2020. The review focuses on the approaches to direct miRNA detection based on the electrochemical signal. It includes a RedOx-labeled probe with different designs, RedOx DNA-intercalating agents, various kinds of RedOx catalysts used to produce a signal response, and finally a free RedOx indicator. Furthermore, the advantages and drawbacks of these approaches are highlighted.
Collapse
|
46
|
Recent Advances in Electrochemical Monitoring of Chromium. SENSORS 2020; 20:s20185153. [PMID: 32917045 PMCID: PMC7570498 DOI: 10.3390/s20185153] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Revised: 09/04/2020] [Accepted: 09/06/2020] [Indexed: 12/31/2022]
Abstract
The extensive use of chromium by several industries conducts to the discharge of an immense quantity of its various forms in the environment which affects drastically the ecological and biological lives especially in the case of hexavalent chromium. Electrochemical sensors and biosensors are useful devices for chromium determination. In the last five years, several sensors based on the modification of electrode surface by different nanomaterials (fluorine tin oxide, titanium dioxide, carbon nanomaterials, metallic nanoparticles and nanocomposite) and biosensors with different biorecognition elements (microbial fuel cell, bacteria, enzyme, DNA) were employed for chromium monitoring. Herein, recent advances related to the use of electrochemical approaches for measurement of trivalent and hexavalent chromium from 2015 to 2020 are reported. A discussion of both chromium species detections and speciation studies is provided.
Collapse
|
47
|
Electrochemical sensors and biosensors using laser-derived graphene: A comprehensive review. Biosens Bioelectron 2020; 168:112565. [PMID: 32927277 DOI: 10.1016/j.bios.2020.112565] [Citation(s) in RCA: 71] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 08/22/2020] [Accepted: 08/24/2020] [Indexed: 12/12/2022]
Abstract
Laser-derived graphene (LDG) technology is gaining attention as a promising material for the development of novel electrochemical sensors and biosensors. Compared to established methods for graphene synthesis, LDG provides many advantages such as cost-effectiveness, fast electron mobility, mask-free, green synthesis, good electrical conductivity, porosity, mechanical stability, and large surface area. This review discusses, in a critical way, recent advancements in this field. First, we focused on the fabrication and doping of LDG platforms using different strategies. Next, the techniques for the modification of LDG sensors using nanomaterials, conducting polymers, biological and artificial receptors are presented. We then discussed the advances achieved for various LDG sensing and biosensing schemes and their applications in the fields of environmental monitoring, food safety, and clinical diagnosis. Finally, the drawbacks and limitations of LDG based electrochemical biosensors are addressed, and future trends are also highlighted.
Collapse
|
48
|
Editorial for the special issue on 6th International Conference on Bio-Sensing Technology - BITE2019. Biosens Bioelectron 2020; 165:112343. [PMID: 32729486 DOI: 10.1016/j.bios.2020.112343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
49
|
Carbon black nanoparticles to sense algae oxygen evolution for herbicides detection: Atrazine as a case study. Biosens Bioelectron 2020; 159:112203. [PMID: 32364935 DOI: 10.1016/j.bios.2020.112203] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Revised: 03/30/2020] [Accepted: 04/07/2020] [Indexed: 11/28/2022]
Abstract
A novel amperometric algae-based biosensor was developed for the detection of photosynthetic herbicides in river water. The green photosynthetic algae Chlamydomonas reinhardtii was immobilized on carbon black modified screen-printed electrodes, exploiting carbon black as smart nanomaterial to monitor changes in algae oxygen evolution during the photosynthetic process. The decrease of oxygen evolution, occurring in the presence of herbicides, results in a decrease of current signals by means of amperometric measurements, in an analyte concentration dependent manner. Atrazine as case study herbicide was detected in a concentration range of 0.1 and 50 μM, with a linear range from 0.1 to 5 μM and a detection limit of 1 nM. No interference was observed in presence of 100 ppb arsenic, 20 ppb copper, 5 ppb cadmium, 10 ppb lead, 10 ppb bisphenol A, and 1 ppb paraoxon, tested as safety limits. A ~25% matrix effect and satisfactory recovery values of 107 ± 10% and 96 ± 8% were obtained in river water for 3 and 5 μM of atrazine, respectively. Stability studies were also performed obtaining a high working stability up to 10 h and repeatability with an RSD of 1.1% (n = 12), as well as a good storage stability up to 3 weeks.
Collapse
|
50
|
A sensitive colorimetric immunoassay based on poly(dopamine) modified magnetic nanoparticles for meat authentication. Lebensm Wiss Technol 2020. [DOI: 10.1016/j.lwt.2020.109045] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|