1
|
Kim DS, Park SH, Ahn JJ, Jeong CM, Yun MJ, Huh JB, Lee SH. In vitro comparison of the accuracy of an occlusal plane transfer method between facebow and POP bow systems in asymmetric ear position. J Adv Prosthodont 2023; 15:271-280. [PMID: 37936837 PMCID: PMC10625888 DOI: 10.4047/jap.2023.15.5.271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 09/25/2023] [Accepted: 10/06/2023] [Indexed: 11/09/2023] Open
Abstract
PURPOSE This in vitro study aimed to compare the accuracy of the conventional facebow system and the newly developed POP (PNUD (Pusan National University Dental School) Occlusal Plane) bow system for occlusal plane transfer in asymmetric ear position. MATERIALS AND METHODS Two dentists participated in this study, one was categorized as Experimenter 1 and the other as Experimenter 2 based on their clinical experience with the facebow (1F, 2F) and POP bow (1P, 2P) systems. The vertical height difference between the two ears of the phantom model was set to 3 mm. Experimenter 1 and Experimenter 2 performed the facebow and POP bow systems on the phantom model 10 times each, and the transfer accuracy was analyzed. The accuracy was evaluated by measuring the angle between the reference virtual plane (RVP) of the phantom model and the experimental virtual plane (EVP) of the upper mounting plate through digital superimposition. All data were statistically analyzed using a paired t-test (P < .05). RESULTS Regardless of clinical experience, the POP bow system (0.53° ± 0.30 (1P) and 0.19° ± 0.18 (2P) for Experimenter 1 and 2, respectively) was significantly more accurate than the facebow system (1.88° ± 0.50 (1F) and 1.34° ± 0.25 (2F), respectively) in the frontal view (P < .05). In the sagittal view, no significant differences were found between the POP bow system (0.92° ± 0.50 (1P) and 0.73° ± 0.42 (2P) for Experimenter 1 and 2, respectively) and the facebow system (0.82° ± 0.49 (1F) and 0.60° ± 0.39 (2F), respectively), regardless of clinical experience (P > .05). CONCLUSION In cases of asymmetric ear position, the POP bow system may transfer occlusal plane information more accurately than the facebow system in the frontal view, regardless of clinical experience.
Collapse
Affiliation(s)
- Dae-Sung Kim
- Department of Prosthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Republic of Korea
| | - So-Hyung Park
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jong-Ju Ahn
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Chang-Mo Jeong
- Department of Prosthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Republic of Korea
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Mi-Jung Yun
- Department of Prosthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Republic of Korea
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Republic of Korea
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - So-Hyoun Lee
- Department of Prosthodontics, Dental Research Institute, Pusan National University Dental Hospital, Yangsan, Republic of Korea
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
2
|
Kim MJ, Cho WT, Hwang SH, Bae JH, Bae EB, Shim JS, Kim JE, Jeong CM, Huh JB. A prospective multicenter clinical study on the efficiency of detachable ball- and spring-retained implant prosthesis. J Adv Prosthodont 2023; 15:202-213. [PMID: 37662852 PMCID: PMC10471505 DOI: 10.4047/jap.2023.15.4.202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 08/01/2023] [Accepted: 08/21/2023] [Indexed: 09/05/2023] Open
Abstract
PURPOSE This prospective clinical study was conducted to evaluate the clinical usefulness of the freely detachable zirconia ball- and spring-retained implant prosthesis (BSRP) through a comparative analysis of screw- and cement-retained implant prosthesis (SCRP). MATERIALS AND METHODS A multi-center, randomized, prospective clinical study evaluating the clinical usefulness of the detachable zirconia ball- and spring-retained implant prostheses was conducted. Sixty-four implant prostheses in 64 patients were examined. Periodic observational studies were conducted at 0, 3, 6, and 12 months after delivery of the implant prosthesis. Factors such as implant success rate, marginal bone resorption, periodontal pocket depth, plaque and bleeding index, and prosthetic complications were evaluated, respectively. RESULTS During the 1-year observation period, all implants survived without functional problems and clinical mobility, showing a 100% implant success rate. Marginal bone resorption was significantly higher in the SCRP group than in the BSRP group only at the time of implant prosthesis delivery (P = .043). In all observation periods, periodontal pocket depth was slightly higher in the BSRP group than in the SCRP group, but there was no significant difference (P > .05). The modified plaque index (mPI) scores of both groups were moderate. Higher ratio of a score 2 in modified sulcus bleeding index (mBI) was observed in the BSRP group in the 6- and 12-months observation. CONCLUSION Within the limitations of this study, the newly developed zirconia ball- and spring-retained implant prosthesis could be considered as an applicable and predictable treatment method along with the existing screw- and cement-retained prosthesis.
Collapse
Affiliation(s)
- Min-Jung Kim
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Won-Tak Cho
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Su-Hyun Hwang
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Ji-Hyeon Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
- The Shapiro Family Laboratory of Viral Oncology and Aging Research & Section of Restorative Dentistry, UCLA School of Dentistry, Los Angeles, CA, USA
| | - June-Sung Shim
- Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Jong-Eun Kim
- Department of Prosthodontics, Yonsei University College of Dentistry, Seoul, Republic of Korea
| | - Chang-Mo Jeong
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
3
|
Son M, Song Y, Yu Y, Kim SY, Huh JB, Bae EB, Cho WT, Na HS, Chung J. The oral microbiome of implant-abutment screw holes compared with the peri-implant sulcus and natural supragingival plaque in healthy individuals. J Periodontal Implant Sci 2023; 53:53.e20. [PMID: 37336525 DOI: 10.5051/jpis.2300100005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 03/14/2023] [Accepted: 04/27/2023] [Indexed: 06/21/2023] Open
Abstract
PURPOSE An implant-supported prosthesis consists of an implant fixture, an abutment, an internal screw that connects the abutment to the implant fixture, and the upper prosthesis. Numerous studies have investigated the microorganisms present on the implant surface, surrounding tissues, and the subgingival microflora associated with peri-implantitis. However, there is limited information regarding the microbiome within the internal screw space. In this study, microbial samples were collected from the supragingival surfaces of natural teeth, the peri-implant sulcus, and the implant-abutment screw hole, in order to characterize the microbiome of the internal screw space in healthy subjects. METHODS Samples were obtained from the supragingival region of natural teeth, the peri-implant sulcus, and the implant screw hole in 20 healthy subjects. DNA was extracted, and the V3-V4 region of the 16S ribosomal RNA was sequenced for microbiome analysis. Alpha diversity, beta diversity, linear discriminant analysis effect size (LEfSe), and network analysis were employed to compare the characteristics of the microbiomes. RESULTS We observed significant differences in beta diversity among the samples. Upon analyzing the significant taxa using LEfSe, the microbial composition of the implant-abutment screw hole's microbiome was found to be similar to that of the other sampling sites' microbiomes. Moreover, the microbiome network analysis revealed a unique network complexity in samples obtained from the implant screw hole compared to those from the other sampling sites. CONCLUSIONS The bacterial composition of the biofilm collected from the implant-abutment screw hole exhibited significant differences compared to the supra-structure of the implant. Therefore, long-term monitoring and management of not only the peri-implant tissue but also the implant screw are necessary.
Collapse
Affiliation(s)
- MinKee Son
- Department of Oral Microbiology, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Yuri Song
- Department of Oral Microbiology, School of Dentistry, Pusan National University, Yangsan, Korea
- Oral Genomics Research Center, Pusan National University, Yangsan, Korea
| | - Yeuni Yu
- Interdisciplinary Program of Genomic Science, Pusan National University, Yangsan, Korea
- Department of Biomedical Informatics, School of Medicine, Pusan National University, Busan, Korea
| | - Si Yeong Kim
- Department of Oral Microbiology, School of Dentistry, Pusan National University, Yangsan, Korea
- Dental Research Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Jung-Bo Huh
- Dental Research Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Korea
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Eun-Bin Bae
- Dental Research Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Korea
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Won-Tak Cho
- Dental Research Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Korea
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Hee Sam Na
- Department of Oral Microbiology, School of Dentistry, Pusan National University, Yangsan, Korea
- Oral Genomics Research Center, Pusan National University, Yangsan, Korea
- Dental Research Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Korea
| | - Jin Chung
- Department of Oral Microbiology, School of Dentistry, Pusan National University, Yangsan, Korea
- Oral Genomics Research Center, Pusan National University, Yangsan, Korea
- Dental Research Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Korea.
| |
Collapse
|
4
|
Bae EB, Cho WT, Park DH, Hwang SH, Lee SH, Yun MJ, Jeong CM, Huh JB. Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. J Adv Prosthodont 2023; 15:155-170. [PMID: 37441720 PMCID: PMC10333096 DOI: 10.4047/jap.2023.15.3.155] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 05/26/2023] [Accepted: 06/20/2023] [Indexed: 07/15/2023] Open
Abstract
PURPOSE This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. RESULTS There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 µm but there was no statistically significant difference within the groups (P > .05). CONCLUSION All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 µm in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown.
Collapse
Affiliation(s)
- Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
- The Shapiro Family Laboratory of Viral Oncology and Aging Research & Section of Restorative Dentistry, UCLA School of Dentistry, Los Angeles, CA, USA
| | - Won-Tak Cho
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Do-Hyun Park
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Su-Hyun Hwang
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - So-Hyoun Lee
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Mi-Jung Yun
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Chang-Mo Jeong
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
5
|
Hwang SH, Moon K, Du W, Cho WT, Huh JB, Bae EB. Effect of Porcine- and Bovine-Derived Xenografts with Hydroxypropyl Methylcellulose for Bone Formation in Rabbit Calvaria Defects. Materials (Basel) 2023; 16:1850. [PMID: 36902966 PMCID: PMC10004720 DOI: 10.3390/ma16051850] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 02/20/2023] [Accepted: 02/21/2023] [Indexed: 06/18/2023]
Abstract
In this study, hydroxypropyl methylcellulose (HPMC) was mixed with particle-type xenografts, derived from two different species (bovine and porcine), to increase the manipulability of bone grafts and compare the bone regeneration ability. Four circular defects with a diameter of 6 mm were formed on each rabbit calvaria, and the defects were randomly divided into three groups: no treatment (control group), HPMC-mixed bovine xenograft (Bo-Hy group), and HPMC-mixed porcine xenograft (Po-Hy group). At eight weeks, micro-computed tomography (µCT) scanning and histomorphometric analyses were performed to evaluate new bone formation within the defects. The results revealed that the defects treated with the Bo-Hy and the Po-Hy showed higher bone regeneration than the control group (p < 0.05), while there was no significant difference between the two xenograft groups (p > 0.05). Within the limitations of the present study, there was no difference in new bone formation between porcine and bovine xenografts with HPMC, and bone graft material was easily moldable with the desired shape during surgery. Therefore, the moldable porcine-derived xenograft with HPMC used in this study could be a promising substitute for the currently used bone grafts as it exhibits good bone regeneration ability for bony defects.
Collapse
Affiliation(s)
- Su-Hyun Hwang
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea
| | - Keumok Moon
- Department of Integrated Biological Science, Pusan National University, Busan 46241, Republic of Korea
| | - Wen Du
- State Key Laboratory of Oral Diseases, & National Clinical Research Center for Oral Diseases, Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610093, China
- The Shapiro Family Laboratory of Viral Oncology and Aging Research, Section of Restorative Dentistry, UCLA School of Dentistry, Los Angeles, CA 90095, USA
| | - Won-Tak Cho
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea
- The Shapiro Family Laboratory of Viral Oncology and Aging Research, Section of Restorative Dentistry, UCLA School of Dentistry, Los Angeles, CA 90095, USA
| |
Collapse
|
6
|
Shin YC, Bae JH, Lee JH, Raja IS, Kang MS, Kim B, Hong SW, Huh JB, Han DW. Enhanced osseointegration of dental implants with reduced graphene oxide coating. Biomater Res 2022; 26:11. [PMID: 35313996 PMCID: PMC8935794 DOI: 10.1186/s40824-022-00257-7] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Accepted: 02/24/2022] [Indexed: 01/15/2023] Open
Abstract
Background The implants of pure titanium (Ti) and its alloys can lead to implant failure because of their poor interaction with bone-associated cells during bone regeneration. Surface modification over implants has achieved successful implants for enhanced osseointegration. Herein, we report a robust strategy to implement bioactive surface modification for implant interface enabled by the combinatorial system of reduced graphene oxide (rGO)-coated sandblasted, large-grit, and acid-etched (SLA) Ti to impart benefits to the implant. Methods We prepared SLA Ti (ST) implants with different surface modifications [i.e., rGO and recombinant human bone morphogenetic protein-2 (rhBMP-2)] and investigated their dental tissue regenerating ability in animal models. We performed comparative studies in surface property, in vitro cellular behaviors, and in vivo osseointegration activity among different groups, including ST (control), rhBMP-2-immobilized ST (BI-ST), rhBMP-2-treated ST (BT-ST), and rGO-coated ST (R-ST). Results Spectroscopic, diffractometric, and microscopic analyses confirmed that rGO was coated well around the surfaces of Ti discs (for cell study) and implant fixtures (for animal study). Furthermore, in vitro and in vivo studies revealed that the R-ST group showed significantly better effects in cell attachment and proliferation, alkaline phosphatase activity, matrix mineralization, expression of osteogenesis-related genes and protein, and osseointegration than the control (ST), BI-ST, and BT-ST groups. Conclusion Hence, we suggest that the rGO-coated Ti can be a promising candidate for the application to dental or even orthopedic implants due to its ability to accelerate the healing rate with the high potential of osseointegration. Supplementary Information The online version contains supplementary material available at 10.1186/s40824-022-00257-7.
Collapse
|
7
|
Seo YH, Hwang SH, Kim YN, Kim HJ, Bae EB, Huh JB. Bone Reconstruction Using Two-Layer Porcine-Derived Bone Scaffold Composed of Cortical and Cancellous Bones in a Rabbit Calvarial Defect Model. Int J Mol Sci 2022; 23:ijms23052647. [PMID: 35269791 PMCID: PMC8910567 DOI: 10.3390/ijms23052647] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 02/12/2022] [Accepted: 02/21/2022] [Indexed: 12/04/2022] Open
Abstract
In this study, we aimed to investigate the bone regeneration efficiency of two-layer porcine-derived bone scaffolds composed of cancellous and cortical bones in a rabbit calvarial defect model. Four circular calvaria defects were formed on cranium of rabbit and were filled with block bone scaffolds of each group: cortical bone block (Cortical group), cancellous bone block (Cancellous group), and two-layer bone block (2layer group). After 8 weeks, new bones were primarily observed in cancellous parts of the Cancellous and 2layer groups, while the Cortical group exhibited few new bones. In the results of new bone volume and area analyses, the Cancellous group showed the highest value, followed by the 2layer group, and were significantly higher than the Cortical group. Within the limitations of this study, the cancellous and two-layer porcine-derived bone scaffolds showed satisfactory bone regeneration efficiency; further studies on regulating the ratio of cortical and cancellous bones in two-layer bones are needed.
Collapse
Affiliation(s)
- Yong-Ho Seo
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (Y.-H.S.); (S.-H.H.)
| | - Su-Hyun Hwang
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (Y.-H.S.); (S.-H.H.)
| | - Yu-Na Kim
- Department of Oral Physiology, Periodontal Diseases Signaling Network Research Center, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (Y.-N.K.); (H.-J.K.)
| | - Hyung-Joon Kim
- Department of Oral Physiology, Periodontal Diseases Signaling Network Research Center, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (Y.-N.K.); (H.-J.K.)
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (Y.-H.S.); (S.-H.H.)
- Section of Restorative Dentistry, University of California, Los Angeles, CA 90095, USA
- Correspondence: (E.-B.B.); (J.-B.H.); Tel.: +82-10-2355-6550 (E.-B.B.); +82-10-8007-9099 (J.-B.H.); Fax: +82-55-360-5134 (J.-B.H.)
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (Y.-H.S.); (S.-H.H.)
- Correspondence: (E.-B.B.); (J.-B.H.); Tel.: +82-10-2355-6550 (E.-B.B.); +82-10-8007-9099 (J.-B.H.); Fax: +82-55-360-5134 (J.-B.H.)
| |
Collapse
|
8
|
Chae SK, Cho WT, Choi JW, Bae EB, Bae JH, Bae GH, Huh JB. Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar. J Adv Prosthodont 2022; 14:12-21. [PMID: 35284053 PMCID: PMC8891684 DOI: 10.4047/jap.2022.14.1.12] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 12/21/2021] [Accepted: 01/04/2022] [Indexed: 11/25/2022] Open
Abstract
PURPOSE The purpose of this study was to investigate changes in retention and wear pattern of Locator® and ADD-TOC attachments on a digital milled bar by performing chewing simulation and repeated insertion/removal of prostheses in fully edentulous models. MATERIALS AND METHODS Locator (Locator®; Zest Anchors Inc., Escondido, CA, USA) was selected as the control group and ADD-TOC (ADD-TOC; PNUAdd Co., Ltd., Busan, Republic of Korea) as the experimental group. A CAD-CAM milled bar was mounted on a master model and 3 threaded holes for connecting a bar attachment was formed using a tap. Locator and ADD-TOC attachments were then attached to the milled bar. Simulated mastication and repeated insertion/removal were performed over 400,000 cyclic loadings and 1,080 insertions/removals, respectively. Wear patterns on deformed attachment were investigated by field emission scanning electron microscopy. RESULTS For the ADD-TOC attachments, chewing simulation and repeated insertion/removal resulted in a mean initial retentive force of 24.43 ± 4.89 N, which were significantly lower than that of the Locator attachment, 34.33 ± 8.25 N (P < .05). Amounts of retention loss relative to baseline for the Locator and ADD-TOC attachments were 21.74 ± 7.07 and 8.98 ± 5.76 N (P < .05). CONCLUSION CAD-CAM milled bar with the ADD-TOC attachment had a lower initial retentive force than the Locator attachment. However, the ADD-TOC attachment might be suitable for long-term use as it showed less deformation and had a higher retentive force after simulated mastication and insertion/removal repetitions.
Collapse
Affiliation(s)
- Sung-Ki Chae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
- Research and Development Institute, Samwon D.M.P, Yangsan, Republic of Korea
| | - Won-Tak Cho
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
- Research and Development Institute, PNUAdd Co., Ltd., Busan, Republic of Korea
| | - Jae-Won Choi
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Ji-Hyeon Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
- Research and Development Institute, PNUAdd Co., Ltd., Busan, Republic of Korea
| | - Gang-Ho Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
- Research and Development Institute, PNUAdd Co., Ltd., Busan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
- Research and Development Institute, PNUAdd Co., Ltd., Busan, Republic of Korea
| |
Collapse
|
9
|
Yun S, Choi D, Choi DJ, Jin S, Yun WS, Huh JB, Shim JH. Bone Fracture-Treatment Method: Fixing 3D-Printed Polycaprolactone Scaffolds with Hydrogel Type Bone-Derived Extracellular Matrix and β-Tricalcium Phosphate as an Osteogenic Promoter. Int J Mol Sci 2021; 22:ijms22169084. [PMID: 34445788 PMCID: PMC8396563 DOI: 10.3390/ijms22169084] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2021] [Revised: 08/20/2021] [Accepted: 08/21/2021] [Indexed: 11/16/2022] Open
Abstract
Bone formation and growth are crucial for treating bone fractures. Improving bone-reconstruction methods using autologous bone and synthetic implants can reduce the recovery time. Here, we investigated three treatments using two different materials, a bone-derived decellularized extracellular matrix (bdECM) and β-tricalcium phosphate (β-TCP), individually and in combination, as osteogenic promoter between bone and 3D-printed polycaprolactone scaffold (6-mm diameter) in rat calvarial defects (8-mm critical diameter). The materials were tested with a human pre-osteoblast cell line (MG63) to determine the effects of the osteogenic promoter on bone formation in vitro. A polycaprolactone (PCL) scaffold with a porous structure was placed at the center of the in vivo rat calvarial defects. The gap between the defective bone and PCL scaffold was filled with each material. Animals were sacrificed four weeks post-implantation, and skull samples were preserved for analysis. The preserved samples were scanned by micro-computed tomography and analyzed histologically to examine the clinical benefits of the materials. The bdECM–β-TCP mixture showed faster bone formation and a lower inflammatory response in the rats. Therefore, our results imply that a bdECM–β-TCP mixture is an ideal osteogenic promoter for treating fractures.
Collapse
Affiliation(s)
- Seokhwan Yun
- Department of Mechanical Engineering, Korea Polytechnic University, Siheung-si 15073, Korea; (S.Y.); (D.-J.C.); (S.J.)
| | - Dami Choi
- Research Institute, T&R Biofab Co., Ltd., Siheung-si 15073, Korea;
| | - Dong-Jin Choi
- Department of Mechanical Engineering, Korea Polytechnic University, Siheung-si 15073, Korea; (S.Y.); (D.-J.C.); (S.J.)
| | - Songwan Jin
- Department of Mechanical Engineering, Korea Polytechnic University, Siheung-si 15073, Korea; (S.Y.); (D.-J.C.); (S.J.)
- Research Institute, T&R Biofab Co., Ltd., Siheung-si 15073, Korea;
| | - Won-Soo Yun
- Department of Mechanical Engineering, Korea Polytechnic University, Siheung-si 15073, Korea; (S.Y.); (D.-J.C.); (S.J.)
- Research Institute, T&R Biofab Co., Ltd., Siheung-si 15073, Korea;
- Correspondence: (W.-S.Y.); (J.-B.H.); (J.-H.S.); Tel.: +82-31-8041-1819 (W.-S.Y.); +82-55-360-5146 (J.-B.H.); +82-31-8041-1819 (J.-H.S.)
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, School of Dentistry, Pusan National University, Yangsan-si 50612, Korea
- Correspondence: (W.-S.Y.); (J.-B.H.); (J.-H.S.); Tel.: +82-31-8041-1819 (W.-S.Y.); +82-55-360-5146 (J.-B.H.); +82-31-8041-1819 (J.-H.S.)
| | - Jin-Hyung Shim
- Department of Mechanical Engineering, Korea Polytechnic University, Siheung-si 15073, Korea; (S.Y.); (D.-J.C.); (S.J.)
- Research Institute, T&R Biofab Co., Ltd., Siheung-si 15073, Korea;
- Correspondence: (W.-S.Y.); (J.-B.H.); (J.-H.S.); Tel.: +82-31-8041-1819 (W.-S.Y.); +82-55-360-5146 (J.-B.H.); +82-31-8041-1819 (J.-H.S.)
| |
Collapse
|
10
|
Kim SY, Lee YJ, Cho WT, Hwang SH, Heo SC, Kim HJ, Huh JB. Preliminary Animal Study on Bone Formation Ability of Commercialized Particle-Type Bone Graft with Increased Operability by Hydrogel. Materials (Basel) 2021; 14:ma14164464. [PMID: 34442986 PMCID: PMC8399214 DOI: 10.3390/ma14164464] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Revised: 07/29/2021] [Accepted: 08/06/2021] [Indexed: 12/31/2022]
Abstract
The purpose of this study was to evaluate the bone-generating ability of a new bovine-derived xenograft (S1-XB) containing hydrogel. For control purposes, we used Bio-Oss and Bone-XB bovine-derived xenografts. S1-XB was produced by mixing Bone-XB and hydrogel. Cell proliferation and differentiation studies were performed to assess cytotoxicities and cell responses. For in vivo study, 8 mm-sized cranial defects were formed in 16 rats, and then the bone substitutes were transplanted into defect sites in the four study groups, that is, a Bio-Oss group, a Bone-XB group, an S1-XB group, and a control (all n = 4); in the control group defects were left empty. Eight weeks after surgery, new bone formation areas were measured histomorphometrically. In the cell study, extracts of Bio-Oss, Bone-XB, and S1-XB showed good results in terms of the osteogenic differentiation of human mesenchymal stem cells (hMSCs) and no cytotoxic reaction was evident. No significant difference was observed between mean new bone areas in the Bio-Oss (36.93 ± 4.27%), Bone-XB (35.07 ± 3.23%), and S1-XB (30.80 ± 6.41%) groups, but new bone area was significantly smaller in the control group (18.73 ± 5.59%) (p < 0.05). Bovine-derived bone graft material containing hydrogel (S1-XB) had a better cellular response and an osteogenic effect similar to Bio-Oss.
Collapse
Affiliation(s)
- So-Yeun Kim
- Department of Prosthodontics, Kyungpook National University Dental Hospital, Daegu 41940, Korea;
| | - You-Jin Lee
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (Y.-J.L.); (W.-T.C.); (S.-H.H.)
| | - Won-Tak Cho
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (Y.-J.L.); (W.-T.C.); (S.-H.H.)
| | - Su-Hyun Hwang
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (Y.-J.L.); (W.-T.C.); (S.-H.H.)
| | - Soon-Chul Heo
- Department of Oral Physiology, Periodontal Diseases Signaling Network Research Center, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan 50612, Korea;
| | - Hyung-Joon Kim
- Department of Oral Physiology, Periodontal Diseases Signaling Network Research Center, Dental and Life Science Institute, School of Dentistry, Pusan National University, Yangsan 50612, Korea;
- Correspondence: (H.-J.K.); (J.-B.H.); Tel.: +82-10-6326-4189 (H.-J.K.); +82-10-8007-9099 (J.-B.H.); Fax: +82-55-510-8208 (H.-J.K.); +82-55-360-5134 (J.-B.H.)
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental and Life Sciences Institute, Education and Research Team for Life Science on Dentistry, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (Y.-J.L.); (W.-T.C.); (S.-H.H.)
- Correspondence: (H.-J.K.); (J.-B.H.); Tel.: +82-10-6326-4189 (H.-J.K.); +82-10-8007-9099 (J.-B.H.); Fax: +82-55-510-8208 (H.-J.K.); +82-55-360-5134 (J.-B.H.)
| |
Collapse
|
11
|
Kim JW, Cho WT, Bae EB, Huh JB. Evaluation of Clinical Accuracy of Implant Abutment-Level Impression Technique Using Digital Superimposition of Customized Abutment. INT J PROSTHODONT 2021; 34:752–755. [PMID: 33651030 DOI: 10.11607/ijp.6959] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Taking a conventional implant abutment-level impression with the gingival retraction technique can cause side effects such as gingival recession and bleeding. In order to overcome these problems, an impression technique using digital superimposition of the customized abutment is newly introduced. In this technique, digital impression data and pre-scanned abutment data are superimposed to reproduce the abutment's location and shape on computer-aided design software. The present investigation was conducted to evaluate the clinical accuracy of the newly adapted digital superimposition impression technique by assessing the fit of fabricated prostheses. The results showed clinical efficacy of this technique, satisfying both convenience and clinically acceptable marginal and internal fit.
Collapse
|
12
|
Park TM, Jung CM, Yoon MJ, Huh JB, Lee SH, Sailer I, Lee H. Accuracy of customized abutment data superimposition according to the extent of scanning area. INT J PROSTHODONT 2021; 34:390–394. [PMID: 33616563 DOI: 10.11607/ijp.7357] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
PURPOSE To evaluate the accuracy of superimposition of customized abutment library data onto scanned abutment data according to the extent of the scanning area. MATERIALS AND METHODS A patient model was fabricated by a 3D printer (Probo, DIO Implant), and a customized abutment was fabricated using a four-axis milling machine (ARUM 4X-100, Doowon). The customized abutment library data were generated using a laboratory scanner (E3, 3Shape) for superimposition after intraoral scanning. A cone-shaped structure was embedded into the library data at the center of the connection part. The customized abutment was placed on the model, and the model was scanned using a laboratory scanner to produce reference data. Three different test group datasets were generated using intraoral scanner and computer-aided design software: (1) fully scanned customized abutment; (2) insufficiently scanned proximal surface; and (3) insufficiently scanned margin, assuming challenging intraoral conditions. The library data were superimposed onto each test group; thereafter, the distance and angle between the reference and test group data were analyzed by using the embedded cone. Statistical analysis was performed using one-way analysis of variance followed by post hoc Tukey test for multiple comparisons. RESULTS There were no statistically significant differences between the mean distance and angle of the test group data (with three different scanning areas) and the reference data. CONCLUSION The superimposition technique can be used clinically, not only when the scan is complete, but also when the proximal surface and margin of the customized abutment have been scanned incompletely.
Collapse
|
13
|
Ahn JJ, Bae EB, Lee JJ, Choi JW, Jeon YC, Jeong CM, Yun MJ, Lee SH, Lee KB, Huh JB. Clinical evaluation of the fit of lithium disilicate crowns fabricated with three different CAD-CAM systems. J Prosthet Dent 2020; 127:239-247. [PMID: 33246562 DOI: 10.1016/j.prosdent.2020.06.031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 06/16/2020] [Accepted: 06/16/2020] [Indexed: 10/22/2022]
Abstract
STATEMENT OF PROBLEM The fit and performance of prostheses fabricated using various computer-aided design and computer-aided manufacturing (CAD-CAM) systems have been evaluated. However, most studies were conducted in vitro, and relatively few have addressed gingival parameters and prosthesis fit under clinical conditions. PURPOSE This clinical study aimed to compare the fit of lithium disilicate crowns produced using 3 CAD-CAM systems and evaluate clinical results up to 6 months after delivery. MATERIAL AND METHODS Forty participants requiring a single crown were recruited. Three monolithic lithium disilicate crowns were fabricated per participant by using 3 different CAD-CAM systems (intraoral scanners, CAD software, and milling machines): CEREC group (CEREC Bluecam, CEREC AC, CEREC MC); EZIS group (EZIS PO, EZIS VR, EZIS HM); and TRIOS group (TRIOS 3, EXO-CAD, ARUM-4X). The fit of the prostheses was assessed via a silicone replica technique, and the most acceptable crown was delivered; 12 were selected from the CEREC group, 16 from the EZIS group, and 12 from the TRIOS group. Follow-up clinical examinations were performed at 1, 3, and 6 months after delivery. The Kruskal-Wallis test with the post hoc Mann-Whitney U test was conducted to analyze significant differences in crown fit and periodontal conditions among the groups (α=.05). RESULTS The marginal gap of the CEREC group was significantly higher than that of the EZIS group, and the occlusal gap of the EZIS group was significantly lower than those of the CEREC and TRIOS groups (P<.05). Probing depth, bleeding index, and plaque index showed no intergroup differences at 6 months (P>.05). CONCLUSIONS The lithium disilicate crowns of all groups showed clinically acceptable fit. No significant differences were found among the groups in terms of periodontal conditions after 6 months.
Collapse
Affiliation(s)
- Jong-Ju Ahn
- Graduate student, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Eun-Bin Bae
- Doctoral Researcher, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jin-Ju Lee
- Graduate student, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jae-Won Choi
- Postdoctoral Researcher, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Young-Chan Jeon
- Professor, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Chang-Mo Jeong
- Professor, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Mi-Jung Yun
- Professor, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - So-Hyoun Lee
- Assistant Professor, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Kyu-Bok Lee
- Associate Professor, Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| | - Jung-Bo Huh
- Associate Professor, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.
| |
Collapse
|
14
|
Ahn JJ, Bae EB, Lee WS, Cho WT, Huh JB. Comparison of clinical fit of three-unit zirconia fixed prostheses fabricated using chairside and labside CAD/CAM systems. J Dent Sci 2020; 15:239-242. [PMID: 32595911 PMCID: PMC7305436 DOI: 10.1016/j.jds.2020.01.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Revised: 01/23/2020] [Indexed: 11/26/2022] Open
Abstract
The purpose of this study was to assess the clinical fit provided by EZIS system, the newly commercialized chairside CAD/CAM system. Prostheses were fabricated with the chairside CAD/CAM system (CS) and labside CAD/CAM system (LS) and marginal, axial, and occlusal fit of the prostheses were compared and analyzed by using replica technique. CS group presented significantly lower fit in all the three fits compared to LS group. Differences in marginal fit, axial fit, and occlusal fit were 12.57 μm (P < 0.001), 3.32 μm (P < 0.05), and 17.20 μm (P < 0.05), respectively. Newly commercialized EZIS system yielded clinically feasible fit; however, further researches covering its biomechanical, physiological, stability aspects are required to promote active clinical use.
Collapse
Affiliation(s)
- Jong-Ju Ahn
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Wan-Sun Lee
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Won-Tak Cho
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
15
|
Cho WT, Bae EB, Ahn JJ, Huh JB. Cordless digital workflow for scanning implant-supported prostheses at the abutment level: A dental technique. J Prosthet Dent 2020; 124:428-430. [PMID: 31918894 DOI: 10.1016/j.prosdent.2019.11.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 10/31/2019] [Accepted: 11/01/2019] [Indexed: 10/25/2022]
Abstract
A custom abutment produced from a digital scan can be used to develop an implant-supported prosthesis with ideal contours. A scan body is used to obtain information about the location of the implant fixture, and the scan body has a special scan region that facilitates superimposition. This dental technique indirectly obtains the margin of the definitive prosthesis by designing the special scan region on a custom abutment and superimposing prescanned abutment data onto intraoral scanned data.
Collapse
Affiliation(s)
- Won-Tak Cho
- Graduate student, Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Eun-Bin Bae
- Doctoral student, Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jong-Ju Ahn
- Graduate student, Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Associate Professor, Department of Prosthodontics, Dental Research Institute, Dental and Life Sciences Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.
| |
Collapse
|
16
|
Jin S, Choi JW, Jeong CM, Huh JB, Lee SH, Lee H, Yun MJ. Evaluating the Wear of Resin Teeth by Different Opposing Restorative Materials. Materials (Basel) 2019; 12:E3684. [PMID: 31717309 PMCID: PMC6888201 DOI: 10.3390/ma12223684] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Revised: 10/31/2019] [Accepted: 11/05/2019] [Indexed: 11/16/2022]
Abstract
The aim of this study was to evaluate the wear properties of resin teeth with different opposing dental restorative materials. One type of resin tooth (Trubyte Biotone) was tested against six types of restorative materials including type III gold alloy (GO), monolithic zirconia (MZ), lithium disilicate glass ceramic (LD), nickel-chromium alloy (NC), feldspathic ceramic (FC), and steatite (ST). Two-body wear tests were performed under a vertical load of 5 kgf and thermo-cycling at 5/55 °C with a total of 120,000 cycles. The wear amount was quantified by measuring the volume loss of the resin teeth and the vertical substance loss of the opposing materials using three-dimensional images. The FC group showed a significantly greater amount of wear of the resin teeth, followed by the ST, NC, LD, MZ, and GO groups. The GO group showed significantly less wear of resin teeth than the other groups. There were no statistically significant differences in the wear of opposing restorative materials between groups. Within the limits of this study, it is recommended that zirconia, rather than feldspathic ceramic, should be used for restorations in the esthetic zone, and gold alloy should be used for areas with little or no esthetic demand.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Mi-Jung Yun
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (S.J.); (J.-W.C.); (C.-M.J.); (J.-B.H.); (S.-H.L.); (H.L.)
| |
Collapse
|
17
|
Choi JW, Ahn JJ, Son K, Huh JB. Three-Dimensional Evaluation on Accuracy of Conventional and Milled Gypsum Models and 3D Printed Photopolymer Models. Materials (Basel) 2019; 12:ma12213499. [PMID: 31731447 PMCID: PMC6862028 DOI: 10.3390/ma12213499] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/22/2019] [Revised: 10/08/2019] [Accepted: 10/24/2019] [Indexed: 11/25/2022]
Abstract
The aim of this study was to evaluate the accuracy of dental models fabricated by conventional, milling, and three-dimensional (3D) printing methods. A reference model with inlay, single crown, and three-unit fixed dental prostheses (FDP) preparations was prepared. Conventional gypsum models (CON) were manufactured from the conventional method. Digital impressions were obtained by intraoral scanner, which were converted into physical models such as milled gypsum models (MIL), stereolithography (SLA), and digital light processing (DLP) 3D printed photopolymer models (S3P and D3P). Models were extracted as standard triangulated language (STL) data by reference scanner. All STL data were superimposed by 3D analysis software and quantitative and qualitative analysis was performed using root mean square (RMS) values and color difference map. Statistical analyses were performed using the Kruskal–Wallis test and Mann–Whitney U test with Bonferroni’s correction. For full arch, the RMS value of trueness and precision in CON was significantly smaller than in the other groups (p < 0.05/6 = 0.008), and there was no significant difference between S3P and D3P (p > 0.05/6 = 0.008). On the other hand, the RMS value of trueness in CON was significantly smaller than in the other groups for all prepared teeth (p < 0.05/6 = 0.008), and there was no significant difference between MIL and S3P (p > 0.05/6 = 0.008). In conclusion, conventional gypsum models showed better accuracy than digitally milled and 3D printed models.
Collapse
Affiliation(s)
- Jae-Won Choi
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (J.-W.C.); (J.-J.A.)
| | - Jong-Ju Ahn
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (J.-W.C.); (J.-J.A.)
| | - Keunbada Son
- Department of Dental Science, Graduate School, Kyungpook National University, 2177 Dalgubeol-daero, Jung-gu, Daegu 41940, Korea;
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea; (J.-W.C.); (J.-J.A.)
- Correspondence: ; Tel.: +82-10-8007-9099; Fax: +82-55-360-5134
| |
Collapse
|
18
|
Kim DS, Ahn JJ, Bae EB, Kim GC, Jeong CM, Huh JB, Lee SH. Influence of Non-Thermal Atmospheric Pressure Plasma Treatment on Shear Bond Strength between Y-TZP and Self-Adhesive Resin Cement. Materials (Basel) 2019; 12:ma12203321. [PMID: 31614730 PMCID: PMC6829206 DOI: 10.3390/ma12203321] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2019] [Revised: 09/28/2019] [Accepted: 10/11/2019] [Indexed: 01/08/2023]
Abstract
The purpose of this study was to evaluate the effect of non-thermal atmospheric pressure plasma (NTP) on shear bond strength (SBS) between yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) and self-adhesive resin cement. For this study, surface energy (SE) was calculated with cube-shaped Y-TZP specimens, and SBS was measured on disc-shaped Y-TZP specimens bonded with G-CEM LinkAce or RelyX U200 resin cylinder. The Y-TZP specimens were classified into four groups according to the surface treatment as follows: Control (no surface treatment), NTP, Sb (Sandblasting), and Sb + NTP. The results showed that the SE was significantly higher in the NTP group than in the Control group (p < 0.05). For the SBS test, in non-thermocycling, the NTP group of both self-adhesive resin cements showed significantly higher SBS than the Control group (p < 0.05). However, regardless of the cement type in thermocycling, there was no significant increase in the SBS between the Control and NTP groups. Comparing the two cements, regardless of thermocycling, the NTP group of G-CEM LinkAce showed significantly higher SBS than that of RelyX U200 (p < 0.05). Our study suggests that NTP increases the SE. Furthermore, NTP increases the initial SBS, which is higher when using G-CEM LinkAce than when using RelyX U200.
Collapse
Affiliation(s)
- Dae-Sung Kim
- Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jong-Ju Ahn
- Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Gyoo-Cheon Kim
- Department of Oral Anatomy and Cell Biology, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
- Research & Development Center, FEAGLE Corporation, Yangsan 50614, Korea.
| | - Chang-Mo Jeong
- Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - So-Hyoun Lee
- Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| |
Collapse
|
19
|
Kim SY, Bae EB, Huh JW, Ahn JJ, Bae HY, Cho WT, Huh JB. Bone Regeneration Using a Three-Dimensional Hexahedron Channeled BCP Block Combined with Bone Morphogenic Protein-2 in Rat Calvarial Defects. Materials (Basel) 2019; 12:ma12152435. [PMID: 31370160 PMCID: PMC6696350 DOI: 10.3390/ma12152435] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/03/2019] [Revised: 07/25/2019] [Accepted: 07/29/2019] [Indexed: 12/14/2022]
Abstract
It is important to obtain sufficient bone mass before implant placement on alveolar bone, and synthetic bone such as biphasic calcium phosphate (BCP) has been studied to secure this. This study used a BCP block bone with a specific structure of the three-dimensional (3D) hexahedron channel and coating with recombinant human bone morphogenetic protein-2 (rhBMP-2) impregnated carboxymethyl cellulose (CMC) was used to examine the enhancement of bone regeneration of this biomaterial in rat calvarial defect. After the preparation of critical-size calvarial defects in fifteen rats, defects were divided into three groups and were implanted with the assigned specimen (n = 5): Boneplant (untreated 3D hexahedron channeled BCP block), Boneplant/CMC (3D hexahedron channeled BCP block coated with CMC), and Boneplant/CMC/BMP (3D hexahedron channeled BCP block coated with CMC containing rhBMP-2). After 4 weeks, the volumetric, histologic, and histometric analyses were conducted to measure the newly formed bone. Histologically, defects in the Boneplant/CMC/BMP group were almost completely filled with new bone compared to the Boneplant and Boneplant/CMC groups. The new bone volume (P < 0.05) and area (P < 0.001) in the Boneplant/CMC/BMP group (20.12% ± 2.17, 33.79% ± 3.66) were much greater than those in the Boneplant (10.77% ± 4.8, 16.48% ± 9.11) and Boneplant/CMC (10.72% ± 3.29, 16.57% ± 8.94) groups, respectively. In conclusion, the 3D hexahedron channeled BCP block adapted rhBMP-2 with carrier CMC showed high possibility as an effective bone graft material.
Collapse
Affiliation(s)
- So-Yeun Kim
- Department of Prosthodontics, Biomedical Research Institute, Pusan National University Hospital, Busan 49241, Korea
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea
| | - Jae-Woong Huh
- Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea
- Seroun Dental Clinic, Suyeong-ro, Nam-gu, Busan 48445, Korea
| | - Jong-Ju Ahn
- Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea
| | - Hyun-Young Bae
- Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea
| | - Won-Tak Cho
- Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| |
Collapse
|
20
|
Lee JJ, Son K, Bae EB, Choi JW, Lee KB, Huh JB. Comparison of the Trueness of Lithium Disilicate Crowns Fabricated From All-in-One and Combination CAD/CAM Systems. INT J PROSTHODONT 2019; 32:352-354. [DOI: 10.11607/ijp.6031] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
21
|
Choi JW, Lee JJ, Bae EB, Huh JB. Implant-supported fixed dental prosthesis with a microlocking implant prosthetic system: A clinical report. J Prosthet Dent 2019; 123:15-19. [PMID: 31076165 DOI: 10.1016/j.prosdent.2018.11.021] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2018] [Revised: 11/07/2018] [Accepted: 11/07/2018] [Indexed: 10/26/2022]
Abstract
A microlocking implant prosthetic system has recently been developed to address the limitations of conventional screw- and cement-retained implant-supported fixed dental prostheses. This prosthesis system consists of a precision-machined abutment and an attachment that includes zirconia balls and a nickel-titanium spring, thus providing retrievability and constant retention of the prosthesis. In addition, screw-related complications are avoided because there is no retention screw. The occlusal access hole is of a smaller diameter than that of conventional screw-retained prostheses, which is beneficial for esthetics and occlusion. It also prevents common complications of cement-retained prostheses because residual cement around the prosthesis can be removed extraorally. This article presents a clinical treatment with this new prosthetic system.
Collapse
Affiliation(s)
- Jae-Won Choi
- Postdoctoral Researcher, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jin-Ju Lee
- Graduate student, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Eun-Bin Bae
- Doctoral student, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Associate Professor, Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.
| |
Collapse
|
22
|
Kim JH, Jeon YC, Huh JB. CRNC6: Prosthetic Rehabilitation with Orthognathic Surgery after Dental Implant for the Patient with Mandibular Prognathism and Loss of Posterior Teeth: A Case Report. J Indian Prosthodont Soc 2018; 18:S47. [PMID: 30532478 PMCID: PMC6238524 DOI: 10.4103/0972-4052.244577] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Affiliation(s)
- Ji-Hyun Kim
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Young-Chan Jeon
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
23
|
Bae EB, Yoo JH, Jeong SI, Kim MS, Lim YM, Ahn JJ, Lee JJ, Lee SH, Kim HJ, Huh JB. Effect of Titanium Implants Coated with Radiation-Crosslinked Collagen on Stability and Osseointegration in Rat Tibia. Materials (Basel) 2018; 11:ma11122520. [PMID: 30545019 PMCID: PMC6316992 DOI: 10.3390/ma11122520] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/05/2018] [Revised: 12/06/2018] [Accepted: 12/10/2018] [Indexed: 12/18/2022]
Abstract
This study aimed to evaluate the titanium (Ti) implants coated with collagen type Ⅰ crosslinked using gamma-irrigation or glutaraldehyde (GA). The in vitro surface observations, quantification assay, and cell studies using human mesenchymal stem cells (hMSCs) were conducted. For in vivo experiments, the implants were divided into three groups and inserted into the rat tibias: control group (non-treated Ti implant), GA group (Ti implants coated with GA-crosslinked collagen) and 25 kGy group (Ti implants coated with gamma-radiation-crosslinked collagen at dose of 25 kGy). The animals were sacrificed at 4 weeks after implantation and the tissue sections were obtained. New bone volume (mm³) and bone-to-implant contact (BIC, %) within the region of interest (ROI) was measured. The in vitro results showed the highest osteogenic differentiation and levels of osteogenesis-related gene expressions in the 25 kGy group without cytotoxicity. The new bone volume of GA group was significantly higher than the control (p < 0.05). In the result of the BIC, the 25 kGy group was significantly higher than the control (p < 0.05). However, there was no significant difference between the experimental groups. Within the limitations of this study, Ti implant coated with gamma-radiation-crosslinked collagen has potential utility without side effects from chemical agents.
Collapse
Affiliation(s)
- Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Ji-Hyun Yoo
- Department of Oral Physiology, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Sung-In Jeong
- Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, 1266 Sinjeong-dong, Jeongeup-si, Jeollabuk-do 56212, Korea.
| | - Min-Su Kim
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Youn-Mook Lim
- Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, 1266 Sinjeong-dong, Jeongeup-si, Jeollabuk-do 56212, Korea.
| | - Jong-Ju Ahn
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jin-Ju Lee
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - So-Hyoun Lee
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Hyung-Joon Kim
- Department of Oral Physiology, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| |
Collapse
|
24
|
Choi JW, Yun BH, Jeong CM, Huh JB. Retentive Properties of Two Stud Attachments with Polyetherketoneketone or Nylon Insert in Mandibular Implant Overdentures. Int J Oral Maxillofac Implants 2018; 33:1079-1088. [PMID: 30231095 DOI: 10.11607/jomi.6023] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
PURPOSE The aim of this study was to compare the retentive properties of an attachment with a nylon insert and an attachment with a polyetherketoneketone (PEKK) insert on two-implant mandibular overdentures during simulated masticatory loadings and insertion/removal cycles. MATERIALS AND METHODS Two attachment systems with nylon inserts or PEKK inserts were investigated, including nylon/low, nylon/medium, nylon/high, PEKK/x-low, PEKK/low, PEKK/medium, and PEKK/high. The canine region of edentulous mandibular overdenture models was retained with two implant analogs through two different stud attachments at interimplant angulations of 0 and 20 degrees. The simulated mastication and insertion/removal cycles were 400,000 cyclic loadings and 1,080 times of insertion/removal. Wear patterns and deformations on the attachment surface were analyzed with scanning electron microscopy. RESULTS At 0 and 20 degrees, initial retentive force was highest in nylon/high and lowest in PEKK/x-low. Final retentive force was highest in PEKK/high and PEKK/medium at 0 and 20 degrees, respectively, and PEKK/x-low was lowest at both angulations. At 0 degrees, nylon/low, nylon/medium, PEKK/x-low, and PEKK/low displayed a significant increase in retention (P < .05), and nylon/high and PEKK/medium showed a significant decrease in retention (P < .05), except PEKK/high, which exhibited no significant decrease (P > .05). At 20 degrees, nylon/low and PEKK/x-low increased retention significantly (P < .05), and nylon/medium, nylon/high, PEKK/low, PEKK/medium, and PEKK/high decreased retention significantly (P < .05). Patrices of both attachment systems barely showed detectable abrasion, while matrices revealed severe wear and surface deformation. Nylon inserts particularly displayed more noticeable wear and deformation than PEKK inserts. CONCLUSION Within the limitations of this investigation, the attachment system with a PEKK insert indicated less abrasion and retention change than the attachment system with a nylon insert on both paralleled implants and axially tilted implants under 400,000 cyclic loadings and 1,080 insertion/removal cycles for 1 year.
Collapse
|
25
|
Huh JB. Development Of Novel Implant Prosthesis System With New Concept For Easy Maintenance. J Indian Prosthodont Soc 2018; 18:S4-S5. [PMID: 30532386 PMCID: PMC6238424 DOI: 10.4103/0972-4052.244575] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Affiliation(s)
- Jung-Bo Huh
- Korean Academy of Prosthodontic Associate Professor and Chair, Department of Prosthodontics School of Dentistry, Pusan National University, Republic of Korea
| |
Collapse
|
26
|
Song CH, Choi JW, Jeon YC, Jeong CM, Lee SH, Kang ES, Yun MJ, Huh JB. Comparison of the Microtensile Bond Strength of a Polyetherketoneketone (PEKK) Tooth Post Cemented with Various Surface Treatments and Various Resin Cements. Materials (Basel) 2018; 11:ma11060916. [PMID: 29844270 PMCID: PMC6025344 DOI: 10.3390/ma11060916] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2018] [Revised: 05/24/2018] [Accepted: 05/25/2018] [Indexed: 11/16/2022]
Abstract
The aim of this in-vitro research was to evaluate the microtensile bond strength in the newly introduced PEKK tooth post with various surface treatments and resin cements. A fiberglass tooth post was included in order to compare it with PEKK as a possible post material. The microtensile bond strengths of the fiberglass post (FRC Postec Plus) and the PEKK post (Pekkton®) were tested using three kinds of self-adhesive resin cements (G-CEM LinkAce, Multilink Speed, and RelyX U200) and one self-etching resin cement (PANAVIA F2.0). The surface treatments of the fiberglass posts were processed according to the manufacturer’s recommendations (F1, application of 37% phosphoric acid etching gel and silanization). For the PEKK post groups, various surface treatments were performed like no surface treatment (P1), sandblasting (P2), silica-coating and silanization (P3), and sandblasting with a composite primer (P4). In the surface treatment, PEKK posts with silica coating and silane treatment (P3) showed a significantly higher microtensile bond strength (mean MPa: 18.09, p < 0.05). The highest microtensile bond strength was shown when the PEKK posts were treated with a silica coating and silane treatment and cemented with RelyX U200 (mean MPa: 22.22). The PEKK posts with surface treatments of silica-coating and silanization or sandblasting displayed superior microtensile bond strengths (mean MPa: 18.09 and 16.25, respectively) compared to the conventional fiberglass posts (mean MPa: 14.93, p < 0.05).
Collapse
Affiliation(s)
- Chan-Hong Song
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jae-Won Choi
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Young-Chan Jeon
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Chang-Mo Jeong
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - So-Hyoun Lee
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Eun-Sook Kang
- Department of Prosthodontics, In-Je University Haeundae Paik Hospital, Busan 48108, Korea.
| | - Mi-Jung Yun
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| |
Collapse
|
27
|
Choi JW, Choi KH, Chae HJ, Chae SK, Bae EB, Lee JJ, Lee SH, Jeong CM, Huh JB. Load-Bearing Capacity and Retention of Newly Developed Micro-Locking Implant Prosthetic System: An In Vitro Pilot Study. Materials (Basel) 2018; 11:ma11040564. [PMID: 29642407 PMCID: PMC5951448 DOI: 10.3390/ma11040564] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2018] [Revised: 04/04/2018] [Accepted: 04/04/2018] [Indexed: 11/16/2022]
Abstract
The aim of this study was to introduce the newly developed micro-locking implant prosthetic system and to evaluate the resulting its characteristics. To evaluate load-bearing capacity, 25 implants were divided into five groups: external-hexagon connection (EH), internal-octagon connection (IO), internal-hexagon connection (IH), one-body implant (OB), micro-locking implant system (ML). The maximum compressive load was measured using a universal testing machine (UTM) according to the ISO 14801. Retention was evaluated in two experiments: (1) a tensile test of the structure modifications of the components (attachment and implant) and (2) a tensile test after cyclic loading (total 5,000,000 cycles, 100 N, 2 Hz). The load-bearing capacity of the ML group was not significantly different from the other groups (p > 0.05). The number of balls in the attachment and the presence of a hexagonal receptacle did not show a significant correlation with retention (p > 0.05), but the shape of the retentive groove in the implant post had a statistically significant effect on retention (p < 0.05). On the other hand, the retention loss was observed during the initial 1,000,000 cycles, but an overall constant retention was maintained afterward. Various preclinical studies on this novel micro-locking implant prosthetic system should continue so that it can be applied in clinical practice.
Collapse
Affiliation(s)
- Jae-Won Choi
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Kyung-Hee Choi
- Research and Development Institute, Cowellmedi Co., Ltd., Busan 46986, Korea.
| | - Hee-Jin Chae
- Research and Development Institute, Samwon Dental Medical Precise Co., Ltd., Yangsan 50603, Korea.
| | - Sung-Ki Chae
- Research and Development Institute, Samwon Dental Medical Precise Co., Ltd., Yangsan 50603, Korea.
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jin-Ju Lee
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - So-Hyoun Lee
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Chang-Mo Jeong
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| |
Collapse
|
28
|
Bae JC, Lee JJ, Shim JH, Park KH, Lee JS, Bae EB, Choi JW, Huh JB. Development and Assessment of a 3D-Printed Scaffold with rhBMP-2 for an Implant Surgical Guide Stent and Bone Graft Material: A Pilot Animal Study. Materials (Basel) 2017; 10:E1434. [PMID: 29258172 PMCID: PMC5744369 DOI: 10.3390/ma10121434] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Revised: 12/12/2017] [Accepted: 12/14/2017] [Indexed: 01/10/2023]
Abstract
In this study, a new concept of a 3D-printed scaffold was introduced for the accurate placement of an implant and the application of a recombinant human bone morphogenetic protein-2 (rhBMP-2)-loaded bone graft. This preliminary study was conducted using two adult beagles to evaluate the 3D-printed polycaprolactone (PCL)/β-tricalcium phosphate (β-TCP)/bone decellularized extracellular matrix (bdECM) scaffold conjugated with rhBMP-2 for the simultaneous use as an implant surgical guide stent and bone graft material that promotes new bone growth. Teeth were extracted from the mandible of the beagle model and scanned by computed tomography (CT) to fabricate a customized scaffold that would fit the bone defect. After positioning the implant guide scaffold, the implant was placed and rhBMP-2 was injected into the scaffold of the experimental group. The two beagles were sacrificed after three months. The specimen block was obtained and scanned by micro-CT. Histological analysis showed that the control and experimental groups had similar new bone volume (NBV, %) but the experimental group with BMP exhibited a significantly higher bone-to-implant contact ratio (BIC, %). Within the limitations of this preliminary study, a 3D-printed scaffold conjugated with rhBMP-2 can be used simultaneously as an implant surgical guide and a bone graft in a large bone defect site. Further large-scale studies will be needed to confirm these results.
Collapse
Affiliation(s)
- Ji Cheol Bae
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jin-Ju Lee
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jin-Hyung Shim
- Department of Mechanical Engineering, Korea Polytechnic University, 237 Sangidaehak-Ro, Siheung 15073, Korea.
| | - Keun-Ho Park
- Department of Mechanical Engineering, Korea Polytechnic University, 237 Sangidaehak-Ro, Siheung 15073, Korea.
| | - Jeong-Seok Lee
- Department of Mechanical Engineering, Korea Polytechnic University, 237 Sangidaehak-Ro, Siheung 15073, Korea.
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jae-Won Choi
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| |
Collapse
|
29
|
Shim JH, Jeong JH, Won JY, Bae JH, Ahn G, Jeon H, Yun WS, Bae EB, Choi JW, Lee SH, Jeong CM, Chung HY, Huh JB. Porosity effect of 3D-printed polycaprolactone membranes on calvarial defect model for guided bone regeneration. ACTA ACUST UNITED AC 2017; 13:015014. [PMID: 29155411 DOI: 10.1088/1748-605x/aa9bbc] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
The appropriate porosity and pore size of barrier membranes were associated with the transportation of biomolecules required for new bone formation and angiogenesis. In this study, we fabricated three-dimensional (3D)-printed resorbable polycaprolactone (PCL) membranes with different porosities (30%, 50%, and 70%) to evaluate the effective pore size for guided bone regeneration (GBR) membranes. To analyze mechanical properties and cytocompatibility, PCL membranes prepared using extrusion-based 3D printing technology were compared in dry and wet conditions and tested in vitro. The proliferation rates and pattern of fibroblasts and preosteoblasts on PCL membranes with different porosities were determined using a cell counting kit-8 assay and scanning electron microscopy. PCL membrane porosity did not affect cell proliferation, but osteogenic differentiation and mechanical properties were increased with lower porosity (30%) on day 14 (p < 0.001). Similar results were found in an in vivo calvarial defect model; new bone formation was significantly higher in PCL membranes with lower porosity (p < 0.001). These results indicate that 3D-printed PCL with 30% porosity (130 μm pore size) is an excellent pore size for GBR membranes.
Collapse
Affiliation(s)
- Jin-Hyung Shim
- Department of Mechanical Engineering, Korea Polytechnic University, 237 Sangidaehak-Ro, Siheung-Si, Gyeonggi-Do, 15073, Republic of Korea
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
30
|
Park DH, Park JM, Choi JW, Kang ES, Bae EB, Jeon YC, Jeong CM, Yun MJ, Huh JB. Accuracy of several implant bite registration techniques: an in-vitro pilot study. J Adv Prosthodont 2017; 9:341-349. [PMID: 29142641 PMCID: PMC5673610 DOI: 10.4047/jap.2017.9.5.341] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2016] [Revised: 03/31/2017] [Accepted: 04/20/2017] [Indexed: 11/08/2022] Open
Abstract
PURPOSE This study evaluated the accuracies of different bite registration techniques for implant-fixed prostheses using three dimensional file analysis. MATERIALS AND METHODS Implant fixtures were placed on the mandibular right second premolar, and the first and second molar in a polyurethane model. Aluwax (A), Pattern Resin (P), and Blu-Mousse (B) were used as the bite registration materials on the healing abutments (H) or temporary abutments (T). The groups were classified into HA, HP, HB, TA, TP, and TB according to each combination. The group using the bite impression coping was the BC group; impression taking and bite registration were performed simultaneously. After impression and bite taking, the scan bodies were connected to the lab analogs of the casts. These casts were scanned using a model scanner. The distances between two reference points in three-dimensional files were measured in each group. One-way ANOVA and Duncan's test were used at the 5% significance level. RESULTS The smallest distance discrepancy was observed in the TB group using the temporary abutments. The Blu-Mousse and HP groups showed the largest distance discrepancy. The TB and BC groups showed a lower distance discrepancy than the HP group (P=.001), and there was no significant difference between the groups using the temporary abutments and healing abutments (P>.05). CONCLUSION Although this study has limitations as an in-vitro investigation, the groups using the temporary abutments to hold the Blu-Mousse record and bite impression coping showed greater accuracy than the group using the healing abutments to hold the pattern resin record.
Collapse
Affiliation(s)
- Do-Hyun Park
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Ji-Man Park
- Department of Prosthodontics, Seoul National University Gwanak Dental Hospital, Seoul, Republic of Korea
| | - Jae-Won Choi
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.,BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Eun-Sook Kang
- Department of Prosthodontics, In-Je University Haeundae Paik Hospital, Busan, Republic of Korea
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.,BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Young-Chan Jeon
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Chang-Mo Jeong
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Mi-Jung Yun
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
31
|
An SJ, Lee SH, Huh JB, Jeong SI, Park JS, Gwon HJ, Kang ES, Jeong CM, Lim YM. Preparation and Characterization of Resorbable Bacterial Cellulose Membranes Treated by Electron Beam Irradiation for Guided Bone Regeneration. Int J Mol Sci 2017; 18:ijms18112236. [PMID: 29068426 PMCID: PMC5713206 DOI: 10.3390/ijms18112236] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Revised: 10/16/2017] [Accepted: 10/18/2017] [Indexed: 11/16/2022] Open
Abstract
Bacterial cellulose (BC) is an excellent biomaterial with many medical applications. In this study, resorbable BC membranes were prepared for guided bone regeneration (GBR) using an irradiation technique for applications in the dental field. Electron beam irradiation (EI) increases biodegradation by severing the glucose bonds of BC. BC membranes irradiated at 100 kGy or 300 kGy were used to determine optimal electron beam doses. Electron beam irradiated BC membranes (EI-BCMs) were evaluated by scanning electron microscopy (SEM), attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy, thermal gravimetric analysis (TGA), and using wet tensile strength measurements. In addition, in vitro cell studies were conducted in order to confirm the cytocompatibility of EI-BCMs. Cell viabilities of NIH3T3 cells on 100k and 300k EI-BCMs (100 kGy and 300 kGy irradiated BC membranes) were significantly greater than on NI-BCMs after 3 and 7 days (p < 0.05). Bone regeneration by EI-BCMs and their biodegradabilities were also evaluated using in vivo rat calvarial defect models for 4 and 8 weeks. Histometric results showed 100k EI-BCMs exhibited significantly larger new bone area (NBA; %) than 300k EI-BCMs at 8 weeks after implantation (p < 0.05). Mechanical, chemical, and biological analyses showed EI-BCMs effectively interacted with cells and promoted bone regeneration.
Collapse
Affiliation(s)
- Sung-Jun An
- Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, 1266 Sinjeong-dong, Jeongeup-si, Jeollabuk-do 56212, Korea.
| | - So-Hyoun Lee
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Sung In Jeong
- Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, 1266 Sinjeong-dong, Jeongeup-si, Jeollabuk-do 56212, Korea.
| | - Jong-Seok Park
- Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, 1266 Sinjeong-dong, Jeongeup-si, Jeollabuk-do 56212, Korea.
| | - Hui-Jeong Gwon
- Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, 1266 Sinjeong-dong, Jeongeup-si, Jeollabuk-do 56212, Korea.
| | - Eun-Sook Kang
- Department of Prosthodontics, In-Je University Haeundae Paik Hospital, Busan 48108, Korea.
| | - Chang-Mo Jeong
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Youn-Mook Lim
- Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, 1266 Sinjeong-dong, Jeongeup-si, Jeollabuk-do 56212, Korea.
| |
Collapse
|
32
|
Lee SH, An SJ, Lim YM, Huh JB. The Efficacy of Electron Beam Irradiated Bacterial Cellulose Membranes as Compared with Collagen Membranes on Guided Bone Regeneration in Peri-Implant Bone Defects. Materials (Basel) 2017; 10:ma10091018. [PMID: 28862689 PMCID: PMC5615673 DOI: 10.3390/ma10091018] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/24/2017] [Revised: 08/16/2017] [Accepted: 08/22/2017] [Indexed: 12/22/2022]
Abstract
Bacterial cellulose (BC) is a natural polysaccharide produced by some bacteria, and consists of a linear polymer linked by β-(1,4) glycosidic bonds. BC has been developed as a material for tissue regeneration purposes. This study was conducted to evaluate the efficacy of resorbable electron beam irradiated BC membranes (EI-BCMs) for guided bone regeneration (GBR). The electron beam irradiation (EI) was introduced to control the biodegradability of BC for dental applications. EI-BCMs had higher porosity than collagen membranes (CMs), and had similar wet tensile strengths to CMs. NIH3T3 cell adhesion and proliferation on EI-BCMs were not significantly different from those on CMs (p > 0.05). Micro-computed tomography (μCT) and histometric analysis in peri-implant dehiscence defects of beagle dogs showed that EI-BCMs were non-significantly different from CMs in terms of new bone area (NBA; %), remaining bone substitute volume (RBA; %) and bone-to-implant contact (BIC; %) (p > 0.05). These results suggest resorbable EI-BCMs can be used as an alternative biomaterial for bone tissue regeneration.
Collapse
Affiliation(s)
- So-Hyoun Lee
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Sung-Jun An
- Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, 1266 Sinjeong-dong, Jeongeup-si, Jeollabuk-do 56212, Korea.
| | - Youn-Mook Lim
- Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, 1266 Sinjeong-dong, Jeongeup-si, Jeollabuk-do 56212, Korea.
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| |
Collapse
|
33
|
Kim AR, Jeon YC, Jeong CM, Yun MJ, Choi JW, Kwon YH, Huh JB. Effect of activation modes on the compressive strength, diametral tensile strength and microhardness of dual-cured self-adhesive resin cements. Dent Mater J 2017; 35:298-308. [PMID: 27041021 DOI: 10.4012/dmj.2015-056] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose of this study was to compare the compressive strength, diametral tensile strength and microhardnss of several selfadhesive resin cements (Rely-X U200, Clearfill SA Luting, G-CEM LinkAce, Maxcem Elite, PermaCem 2.0, and Zirconite) using different activation modes (self-cured, light-cured) and testing time (immediately, 24 h, thermocycling). Specimens were prepared for the compressive strength (Ø 4×6 mm) and diametral tensile strength and microhardness (Ø 6×3 mm) according to ISO standards. The strength after 24 h was higher than immediately after. In addition, G-CEM showed the highest values. In terms of the activation modes, Rely-X U200, PermaCem 2.0 had higher values in the light-curing than the self-curing. In conclusion, all cements demonstrated clinically available strength values and revealed differences in strength according to their composition, testing time and activation mode. Furthermore, correlation was found between the microhardness (degree of conversion) and mechanical strengths of the cements tested.
Collapse
Affiliation(s)
- Ah-Rang Kim
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University
| | | | | | | | | | | | | |
Collapse
|
34
|
Choi JW, Kim SY, Bae JH, Bae EB, Huh JB. In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses. J Adv Prosthodont 2017; 9:244-251. [PMID: 28874990 PMCID: PMC5582089 DOI: 10.4047/jap.2017.9.4.244] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2016] [Revised: 02/17/2017] [Accepted: 03/15/2017] [Indexed: 11/25/2022] Open
Abstract
PURPOSE The purpose of this study was to determine fracture resistance and failure modes of three-unit fixed dental prostheses (FDPs) made of lithium disilicate pressed on zirconia (LZ), monolithic lithium disilicate (ML), and monolithic zirconia (MZ). MATERIALS AND METHODS Co-Cr alloy three-unit metal FDPs model with maxillary first premolar and first molar abutments was fabricated. Three different FDPs groups, LZ, ML, and MZ, were prepared (n = 5 per group). The three-unit FDPs designs were identical for all specimens and cemented with resin cement on the prepared metal model. The region of pontic in FDPs was given 50,000 times of cyclic preloading at 2 Hz via dental chewing simulator and received a static load until fracture with universal testing machine fixed at 10°. The fracture resistance and mode of failure were recorded. Statistical analyses were performed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni's correction (α=0.05/3=0.017). RESULTS A significant difference in fracture resistance was found between LZ (4943.87 ± 1243.70 N) and ML (2872.61 ± 658.78 N) groups, as well as between ML and MZ (4948.02 ± 974.51 N) groups (P<.05), but no significant difference was found between LZ and MZ groups (P>.05). With regard to fracture pattern, there were three cases of veneer chipping and two interfacial fractures in LZ group, and complete fracture was observed in all the specimens of ML and MZ groups. CONCLUSION Compared to monolithic lithium disilicate FDPs, monolithic zirconia FDPs and lithium disilicate glass ceramics pressed on zirconia-based FDPs showed superior fracture resistance while they manifested comparable fracture resistances.
Collapse
Affiliation(s)
- Jae-Won Choi
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.,BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - So-Yeun Kim
- Department of Prosthodontics, Pusan National University Hospital, Pusan, Republic of Korea
| | - Ji-Hyeon Bae
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.,BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.,BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translation Dental Science, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
35
|
Kim JW, Shin YC, Lee JJ, Bae EB, Jeon YC, Jeong CM, Yun MJ, Lee SH, Han DW, Huh JB. The Effect of Reduced Graphene Oxide-Coated Biphasic Calcium Phosphate Bone Graft Material on Osteogenesis. Int J Mol Sci 2017; 18:E1725. [PMID: 28786931 PMCID: PMC5578115 DOI: 10.3390/ijms18081725] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 07/31/2017] [Accepted: 08/06/2017] [Indexed: 12/16/2022] Open
Abstract
This study was conducted to evaluate the effect of biphasic calcium phosphate (BCP) coated with reduced graphene oxide (rGO) as bone graft materials on bone regeneration. The rGO-coated BCP bone graft material was fabricatied by mixing rGO and BCP at various concentrations. The surface charge of rGO-coated BCP was measured to be -14.43 mV, which formed a static electrostatic interaction. Cell viabilities were significantly diminished at higher concentrations of ≥100 μg/mL. The calvarial defects of 48 rats were implanted rGO-coated BCPs at a weight ratio of 2:1000 (rGO2), 4:1000 (rGO4), and 10:1000 (rGO10), repectively. BCP was used as a control group. The micro-CT and histological analysis were performed to evaluate new bone formation at 2 and 8 weeks after surgery. The results showed that the new bone volume (mm³) was significantly higher in the experimental groups than in the control group. Histological analysis showed that new bone areas (%) were significantly higher in the rGO2 and rGO10 than in the control, and significantly higher in rGO4 than in the rGO2 and rGO10. Conclusively, the rGO-coated BCP was found to be effective on osteogenesis and the concentration of the composite was an important factor.
Collapse
Affiliation(s)
- Jeong-Woo Kim
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Yong Cheol Shin
- Department of CognoMechatronics Engineering, Pusan National University, Busan 46241, Korea.
| | - Jin-Ju Lee
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Eun-Bin Bae
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Young-Chan Jeon
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Chang-Mo Jeong
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Mi-Jung Yun
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - So-Hyoun Lee
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Dong-Wook Han
- Department of CognoMechatronics Engineering, Pusan National University, Busan 46241, Korea.
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| |
Collapse
|
36
|
Kim JS, Bae JH, Yun MJ, Huh JB. In vitro assessment of cutting efficiency and durability of zirconia removal diamond rotary instruments. J Prosthet Dent 2017; 117:775-783. [DOI: 10.1016/j.prosdent.2016.09.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2016] [Revised: 09/08/2016] [Accepted: 09/08/2016] [Indexed: 10/20/2022]
|
37
|
Hwang KS, Choi JW, Kim JH, Chung HY, Jin S, Shim JH, Yun WS, Jeong CM, Huh JB. Comparative Efficacies of Collagen-Based 3D Printed PCL/PLGA/β-TCP Composite Block Bone Grafts and Biphasic Calcium Phosphate Bone Substitute for Bone Regeneration. Materials (Basel) 2017; 10:ma10040421. [PMID: 28772780 PMCID: PMC5506921 DOI: 10.3390/ma10040421] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Revised: 04/04/2017] [Accepted: 04/14/2017] [Indexed: 11/16/2022]
Abstract
The purpose of this study was to compare bone regeneration and space maintaining ability of three-dimensional (3D) printed bone grafts with conventional biphasic calcium phosphate (BCP). After mixing polycaprolactone (PCL), poly (lactic-co-glycolic acid) (PLGA), and β-tricalcium phosphate (β-TCP) in a 4:4:2 ratio, PCL/PLGA/β-TCP particulate bone grafts were fabricated using 3D printing technology. Fabricated particulate bone grafts were mixed with atelocollagen to produce collagen-based PCL/PLGA/β-TCP composite block bone grafts. After formation of calvarial defects 8 mm in diameter, PCL/PLGA/β-TCP composite block bone grafts and BCP were implanted into bone defects of 32 rats. Although PCL/PLGA/β-TCP composite block bone grafts were not superior in bone regeneration ability compared to BCP, the results showed relatively similar performance. Furthermore, PCL/PLGA/β-TCP composite block bone grafts showed better ability to maintain bone defects and to support barrier membranes than BCP. Therefore, within the limitations of this study, PCL/PLGA/β-TCP composite block bone grafts could be considered as an alternative to synthetic bone grafts available for clinical use.
Collapse
Affiliation(s)
- Kyoung-Sub Hwang
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jae-Won Choi
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jae-Hun Kim
- Department of Mechanical System Engineering, Graduate School of Knowledge-Based Technology and Energy, Korea Polytechnic University, 237 Sangidaehak-Ro, Siheung-Si, Gyeonggi-Do 15073, Korea.
| | - Ho Yun Chung
- Department of Plastic and Reconstructive Surgery, Kyungpook National University, School of Medicine, 130 Dongdeok-ro, Jung-gu, Daegu 41944, Korea.
| | - Songwan Jin
- Department of Mechanical Engineering, Korea Polytechnic University, 237 Sangidaehak-Ro, Siheung-Si, Gyeonggi-Do 15073, Korea.
| | - Jin-Hyung Shim
- Department of Mechanical Engineering, Korea Polytechnic University, 237 Sangidaehak-Ro, Siheung-Si, Gyeonggi-Do 15073, Korea.
| | - Won-Soo Yun
- Department of Mechanical Engineering, Korea Polytechnic University, 237 Sangidaehak-Ro, Siheung-Si, Gyeonggi-Do 15073, Korea.
| | - Chang-Mo Jeong
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Institute of Translational Dental Sciences, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| |
Collapse
|
38
|
Yun MJ, Jeon YC, Jeong CM, Huh JB. Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques. J Adv Prosthodont 2017; 9:1-13. [PMID: 28243386 PMCID: PMC5321583 DOI: 10.4047/jap.2017.9.1.1] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Revised: 11/09/2016] [Accepted: 12/20/2016] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS Artificial tooth in a master model and abutment teeth in ten patients were restored with cast gold crowns fabricated from the digital and the conventional impression technique. The forty silicone replicas were cut in three sections; each section was evaluated in nine points. The measurement was carried out by using a measuring microscope and I-Soultion. Data from the silicone replica were analyzed and all tests were performed with α-level of 0.05. RESULTS 1. The average gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. 2. In marginal and internal axial gap of cast gold crowns, no statistical differences were found between the two impression techniques. 3. The internal occlusal gaps of cast gold crowns fabricated from the digital impression technique were larger than those of the conventional impression technique significantly. CONCLUSION Both prostheses presented clinically acceptable results with comparing the fit. The prostheses fabricated from the digital impression technique showed more gaps, in respect of occlusal surface.
Collapse
Affiliation(s)
- Mi-Jung Yun
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Young-Chan Jeon
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Chang-Mo Jeong
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
39
|
Park JC, Bae EB, Kim SE, Kim SY, Choi KH, Choi JW, Bae JH, Ryu JJ, Huh JB. Effects of BMP-2 Delivery in Calcium Phosphate Bone Graft Materials with Different Compositions on Bone Regeneration. Materials (Basel) 2016; 9:ma9110954. [PMID: 28774075 PMCID: PMC5457269 DOI: 10.3390/ma9110954] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2016] [Revised: 11/07/2016] [Accepted: 11/17/2016] [Indexed: 12/18/2022]
Abstract
This study was undertaken to investigate the effect of loading rhBMP-2 onto biphasic calcium phosphate (BCP) and calcium pyrophosphate (CPP) on bone regeneration, and to examine the efficacies of BCP and CPP as rhBMP-2 carriers. Specimens were divided into the BCP, CPP, BCP/BMP, and CPP/BMP groups; BCP and CPP were in granules and not coated with rhBMP-2. BCP/BMP and CPP/BMP were prepared as discs, which were treated with rhBMP-2 and collagen. Physical and biological features were investigated using in-vitro and in-vivo tests. New bone area percentages (%) in the BCP/BMP and CPP/BMP groups were significantly greater than in the BCP and CPP groups. At weeks 4 and 8 post-implantation, CPP/BMP showed the most new bone growth. Within the limitations of this study, treatment of BCP and CPP with rhBMP-2 significantly enhanced bone regeneration. CPP was found to be a suitable carrier for rhBMP-2.
Collapse
Affiliation(s)
- Jin-Chul Park
- Department of Dentistry, School of Medicine, Korea University, Seoul 02841, Korea.
| | - Eun-Bin Bae
- Department of Prosthodontics, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Se-Eun Kim
- Department of Veterinary Surgery, College of Veterinary Medicine, Chonnam National University, Gwangju 61186, Korea.
| | - So-Yun Kim
- School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Kyung-Hee Choi
- Tissue Biotech Institute, Cowellmedi Co., Ltd., Busan 46986, Korea.
| | - Jae-Won Choi
- Department of Prosthodontics, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Ji-Hyeon Bae
- Department of Prosthodontics, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| | - Jae-Jun Ryu
- Department of Dentistry, School of Medicine, Korea University, Seoul 02841, Korea.
| | - Jung-Bo Huh
- Department of Prosthodontics, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea.
| |
Collapse
|
40
|
Choi JW, Bae JH, Jeong CM, Huh JB. Retention and wear behaviors of two implant overdenture stud-type attachments at different implant angulations. J Prosthet Dent 2016; 117:628-635. [PMID: 27863857 DOI: 10.1016/j.prosdent.2016.09.027] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2016] [Revised: 09/07/2016] [Accepted: 09/07/2016] [Indexed: 10/20/2022]
Abstract
STATEMENT OF PROBLEM Implant angulation should be considered when selecting an attachment. Some in vitro studies have investigated the relationship between implant angulation and changes in the retention force of the stud attachment, but few studies have evaluated the effect of cyclic loading and repeated cycles of insertion and removal on the stud attachment. PURPOSE The purpose of this in vitro study was to evaluate the effects of implant angulation on the retentive characteristics of overdentures with 2 different stud attachments, an experimental system and O-rings in red and orange, after cyclic loading and repeated insertion and removal cycles. MATERIAL AND METHODS The canine region of a mandibular experimental model was fitted with 2 implant fixtures with 2 different stud attachment systems at implant angulations of 0, 15, or 30 degrees. A mastication simulator was used to simulate cyclic loading, and a universal testing machine was used to evaluate retentive force changes after repeated insertion and removal cycles. To simulate the numbers of mastication and insertion and removal cycles per annum, 400000 cyclic loadings and 1080 insertion and removal cycles were performed. Wear patterns and attachment surface deformations were evaluated by scanning electron microscopy. Data were analyzed using the Kruskal-Wallis test, Mann-Whitney U test with Bonferroni correction (α=.05/3=.017), and the paired-sample Student t test (α=.05). RESULTS When retentive forces before and after testing were compared, O-ring showed significant retention loss at all implant angulations (P<.001). In contrast, the experimental system showed little retention loss in the 0- and 15-degree models (P>.05), whereas the 30-degree model showed a significant increase in retentive force (P=.001). At all implant angulations, retention loss increased significantly for the orange O-ring, followed by the red O-ring, and the experimental system (P<.001). Scanning electron microscopy analysis showed more intense wear in the matrix than the patrix (abutment that matches to matrix) and more severe wear and deformation of the O-ring rubber matrix than of the experimental zirconia ball. CONCLUSIONS Upon completion of the experiment, wear and deformation were found for all attachment systems. Even when implants are not installed in parallel, the experimental system can be used without involving great loss of retention.
Collapse
Affiliation(s)
- Jae-Won Choi
- Doctoral student, Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Ji-Hyeon Bae
- Graduate student, Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Chang-Mo Jeong
- Professor, Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Associate Professor, Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea.
| |
Collapse
|
41
|
Shin YG, Kim SY, Lee HK, Jeong CM, Lee SH, Huh JB. Effect of Double Screw on Abutment Screw Loosening in Single-Implant Prostheses. INT J PROSTHODONT 2016; 29:445-7. [PMID: 27611745 DOI: 10.11607/ijp.4791] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
PURPOSE This study was conducted to assess the effect of using a double screw on the prevention of abutment screw loosening. MATERIALS AND METHODS Internal connected abutment with a single screw (IS), internal connected abutment with a double screw (ID), external connected abutment with a single screw (ES), and external connected abutment with a double screw (ED) groups were prepared (n = 10 in each group). After 50,000 loading cycles, postload removal torque loss (RTL) percentage was measured. RESULTS Postload RTL of ID and ED were smaller than those of IS and ES (P = .000 and P = .039, respectively). CONCLUSION This study showed that a double screw was more effective in prevention of screw loosening.
Collapse
|
42
|
Eom TG, Kim HW, Jeon GR, Yun MJ, Huh JB, Jeong CM. Effects of Different Implant Osteotomy Preparation Sizes on Implant Stability and Bone Response in the Minipig Mandible. Int J Oral Maxillofac Implants 2016; 31:997-1006. [DOI: 10.11607/jomi.4165] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
43
|
Seo YH, Bae EB, Kim JW, Lee SH, Yun MJ, Jeong CM, Jeon YC, Huh JB. Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment. J Adv Prosthodont 2016; 8:313-20. [PMID: 27555901 PMCID: PMC4993845 DOI: 10.4047/jap.2016.8.4.313] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2016] [Revised: 05/30/2016] [Accepted: 07/12/2016] [Indexed: 11/17/2022] Open
Abstract
PURPOSE The aim of this study was to evaluate the clinical findings and patient satisfaction on implant overdenture designed with Locator implant attachment or Locator bar attachment in mandibular edentulous patients. MATERIALS AND METHODS Implant survival rate, marginal bone loss, probing depth, peri-implant inflammation, bleeding, plaque, calculus, complications, and satisfaction were evaluated on sixteen patients who were treated with mandibular overdenture and have used it for at least 1 year (Locator implant attachment: n=8, Locator bar attachment: n=8). RESULTS Marginal bone loss, probing depth, plaque index of the Locator bar attachment group were significantly lower than the Locator implant attachment group (P<.05). There was no significant difference on bleeding, peri-implant inflammation, and patient satisfaction between the two denture types (P>.05). The replacement of the attachment components was the most common complication in both groups. Although there was no correlation between marginal bone loss and plaque index, a significant correlation was found between marginal bone loss and probing depth. CONCLUSION The Locator bar attachment group indicates lesser marginal bone loss and need for maintenance, as compared with the Locator implant attachment group. This may be due to the splinting effect among implants rather than the types of Locator attachment.
Collapse
Affiliation(s)
- Yong-Ho Seo
- Prosthodontics, Dental Research Insititute, Pusan Natinal University Dental Hospital, Yangsan, Republic of Korea
| | - Eun-Bin Bae
- Prosthodontics, Dental Research Insititute, Pusan Natinal University Dental Hospital, Yangsan, Republic of Korea
| | - Jung-Woo Kim
- Prosthodontics, Dental Research Insititute, Pusan Natinal University Dental Hospital, Yangsan, Republic of Korea
| | - So-Hyoun Lee
- Prosthodontics, Dental Research Insititute, Pusan Natinal University Dental Hospital, Yangsan, Republic of Korea
| | - Mi-Jung Yun
- Prosthodontics, Dental Research Insititute, Pusan Natinal University Dental Hospital, Yangsan, Republic of Korea
| | - Chang-Mo Jeong
- Prosthodontics, Dental Research Insititute, Pusan Natinal University Dental Hospital, Yangsan, Republic of Korea
| | - Young-Chan Jeon
- Prosthodontics, Dental Research Insititute, Pusan Natinal University Dental Hospital, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Prosthodontics, Dental Research Insititute, Pusan Natinal University Dental Hospital, Yangsan, Republic of Korea
| |
Collapse
|
44
|
Kim SY, Choi JW, Ju SW, Ahn JS, Yoon MJ, Huh JB. Fracture Strength After Fatigue Loading of Lithium Disilicate Pressed Zirconia Crowns. INT J PROSTHODONT 2016; 29:369-71. [PMID: 27479345 DOI: 10.11607/ijp.4602] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
PURPOSE The aim of this study was to evaluate the fracture resistance of fatigued lithium disilicate pressed zirconia crowns versus other ceramic crowns. MATERIALS AND METHODS Lithium disilicate pressed zirconia, fluorapatite pressed zirconia, monolithic lithium disilicate, and monolithic zirconia crowns were fabricated. Cyclic and static loadings were applied to the mesiobuccal cusp tip after thermocycling and fracture strengths were recorded. RESULTS Fatigued lithium disilicate pressed zirconia crowns were found to have a fracture resistance of 9,117.81 ± 727.04 N, compared with 9,240.61 ± 887.21 N for monolithic zirconia crowns, 3,030.18 ± 1,505.83 N for fluorapatite pressed zirconia crowns, and 4,173.94 ± 877.46 N for monolithic lithium disilicate crowns (P = .001). CONCLUSION This in vitro study shows that fatigued lithium disilicate pressed zirconia and monolithic zirconia crowns have better fracture resistance than fluorapatite pressed zirconia and monolithic lithium disilicate crowns.
Collapse
|
45
|
Choi JW, Bae IH, Noh TH, Ju SW, Lee TK, Ahn JS, Jeong TS, Huh JB. Wear of primary teeth caused by opposed all-ceramic or stainless steel crowns. J Adv Prosthodont 2016; 8:43-52. [PMID: 26949487 PMCID: PMC4769889 DOI: 10.4047/jap.2016.8.1.43] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Revised: 11/18/2015] [Accepted: 12/14/2015] [Indexed: 11/23/2022] Open
Abstract
PURPOSE This study was conducted to evaluate the effects of full-coverage all-ceramic zirconia, lithium disilicate glass-ceramic, leucite glass-ceramic, or stainless steel crowns on antagonistic primary tooth wear. MATERIALS AND METHODS There were four study groups: the stainless steel (Steel) group, the leucite glass-ceramic (Leucite) group, the lithium disilicate glass-ceramic (Lithium) group, and the monolithic zirconia (Zirconia) group. Ten flat crown specimens were prepared per group; opposing teeth were prepared using primary canines. A wear test was conducted over 100,000 chewing cycles using a dual-axis chewing simulator and a 50 N masticating force, and wear losses of antagonistic teeth and restorative materials were calculated using a three-dimensional profiling system and an electronic scale, respectively. Statistical significance was determined using One-way ANOVA and Tukey's test (P<.05). RESULTS The Leucite group (2.670±1.471 mm3) showed the greatest amount of antagonist tooth wear, followed by in decreasing order by the Lithium (2.042±0.696 mm3), Zirconia (1.426±0.477 mm3), and Steel groups (0.397±0.192 mm3). Mean volume losses in the Leucite and Lithium groups were significantly greater than in the Steel group (P<.05). No significant difference was observed between mean volume losses in the Zirconia and Steel groups (P>.05). CONCLUSION Leucite glass-ceramic and lithium disilicate glass-ceramic cause more primary tooth wear than stainless steel or zirconia.
Collapse
Affiliation(s)
- Jae-Won Choi
- Department of Prosthodontics, Dental Research Institute, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Ik-Hyun Bae
- Woorimi Dental Clinic, Busan, Republic of Korea.; Department of Pediatric Dentistry, Dental Research Institute, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Tae-Hwan Noh
- Department of Pediatric Dentistry, Dental Research Institute, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Sung-Won Ju
- Dental Research Institute and Department of Biomaterials Science, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | | | - Jin-Soo Ahn
- Dental Research Institute and Department of Biomaterials Science, School of Dentistry, Seoul National University, Seoul, Republic of Korea
| | - Tae-Sung Jeong
- Department of Pediatric Dentistry, Dental Research Institute, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|
46
|
Lee SH, Lim YM, Jeong SI, An SJ, Kang SS, Jeong CM, Huh JB. The effect of bacterial cellulose membrane compared with collagen membrane on guided bone regeneration. J Adv Prosthodont 2015; 7:484-95. [PMID: 26816579 PMCID: PMC4722153 DOI: 10.4047/jap.2015.7.6.484] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Revised: 11/30/2015] [Accepted: 12/01/2015] [Indexed: 11/29/2022] Open
Abstract
PURPOSE This study was to evaluate the effects of bacterial cellulose (BC) membranes as a barrier membrane on guided bone regeneration (GBR) in comparison with those of the resorbable collagen membranes. MATERIALS AND METHODS BC membranes were fabricated using biomimetic technology. Surface properties were analyzed, Mechanical properties were measured, in vitro cell proliferation test were performed with NIH3T3 cells and in vivo study were performed with rat calvarial defect and histomorphometric analysis was done. The Mann-Whitney U test and the Wilcoxon signed rank test was used (α<.05). RESULTS BC membrane showed significantly higher mechanical properties such as wet tensile strength than collagen membrane and represented a three-dimensional multilayered structure cross-linked by nano-fibers with 60 % porosity. In vitro study, cell adhesion and proliferation were observed on BC membrane. However, morphology of the cells was found to be less differentiated, and the cell proliferation rate was lower than those of the cells on collagen membrane. In vivo study, the grafted BC membrane did not induce inflammatory response, and maintained adequate space for bone regeneration. An amount of new bone formation in defect region loaded with BC membrane was significantly similar to that of collagen membrane application. CONCLUSION BC membrane has potential to be used as a barrier membrane, and efficacy of the membrane on GBR is comparable to that of collagen membrane.
Collapse
Affiliation(s)
- So-Hyoun Lee
- Department of Prosthodontics, Dental Research Institute, Biomedical Research Institute, School of Dentistry, Pusan National University, YangSan, Republic of Korea
| | - Youn-Mook Lim
- Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup, Republic of Korea
| | - Sung In Jeong
- Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup, Republic of Korea
| | - Sung-Jun An
- Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup, Republic of Korea
| | - Seong-Soo Kang
- Department of Veterinary Surgery, College of Veterinary Medicine, Chonnam National University, Gwangju, Republic of Korea
| | - Chang-Mo Jeong
- Department of Prosthodontics, Dental Research Institute, Biomedical Research Institute, School of Dentistry, Pusan National University, YangSan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, Biomedical Research Institute, School of Dentistry, Pusan National University, YangSan, Republic of Korea
| |
Collapse
|
47
|
Nam SJ, Yoon MJ, Kim WH, Ryu GJ, Bang MK, Huh JB. Marginal and Internal Fit of Conventional Metal-Ceramic and Lithium Disilicate CAD/CAM Crowns. INT J PROSTHODONT 2015; 28:519-21. [PMID: 26340013 DOI: 10.11607/ijp.4089] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
This study aimed to evaluate and compare the marginal and internal gap widths of lithium disilicate computer-aided design / computer-assisted manufacture (LDC) crowns and conventionally produced porcelain-fused-to-metal (PFM) crowns. A convenience sample of 21 patients treated with a single restoration was selected. PFM and LDC crowns were fabricated for each selected abutment tooth, following traditional crown preparation. Silicone replicas were produced, and internal gaps and marginal gaps were measured. Internal gaps were significantly larger for the axial and occlusal surfaces of LDC crowns than for those of PFM crowns (P < .001). Marginal gaps were not significantly different (P > .05). Both LDC crowns and PFM crowns showed clinically acceptable marginal fit.
Collapse
|
48
|
Huh JB, Kim JH, Kim S, Lee SH, Shim KM, Kim SE, Kang SS, Jeong CM. Effects of PMMA and Cross-Linked Dextran Filler for Soft Tissue Augmentation in Rats. Int J Mol Sci 2015; 16:28523-33. [PMID: 26633376 PMCID: PMC4691059 DOI: 10.3390/ijms161226112] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Revised: 10/27/2015] [Accepted: 11/20/2015] [Indexed: 11/23/2022] Open
Abstract
This study was conducted for evaluation of the ability to maintain efficacy and biocompatibility of cross-linked dextran in hydroxypropyl methylcellulose (DiHM) and cross-linked dextran mixed with PMMA in hydroxypropyl methylcellulose (PDiHM), compared with hyaluronic acid (HA) filler. Saline and HA solution was administered in the negative and positive control groups, and DiHM and PDiHM were administered in the test groups (n = 10 in each group). The site of cranial subcutaneous injection was the mid-point of the interpupillary line, and the site of intraoral submucosal injection was the ridge crest 2 mm below the cervical line of the mandibular left incisor. Before and immediately after filler injection, intraoral photos and lateral cephalometric radiographs were taken for analysis and comparison of the effect of the filler on the injection sites. The filler injected areas were converted into sequential size changes (%) of the baseline. Histomorphologic examination was performed after 12 weeks. The smallest value in the filler injected area was observed during the experimental period in the normal saline group (p < 0.001), which was almost absorbed at 4 weeks (7.19% ± 12.72%). The HA group exhibited a steady decrease in sequential size and showed a lower value than the DiHM and PDiHM groups (saline < HA < DHiM, PDHiM, p < 0.001). DiHM and PDiHM tended to increase for the first 4 weeks and later decreased until 12 weeks. In this study on DiHM and PDiHM, there was no histological abnormality in cranial skin and oral mucosa. DiHM and PDiHM filler materials with injection system provide an excellent alternative surgical method for use in oral and craniofacial fields.
Collapse
Affiliation(s)
- Jung-Bo Huh
- Department of Prosthodontics, Dental Research Institute, School of Dentistry, Pusan National University, YangSan 676-870, Korea.
| | - Joo-Hyun Kim
- Department of Prosthodontics, Dental Research Institute, School of Dentistry, Pusan National University, YangSan 676-870, Korea.
| | - Soyun Kim
- School of Dentistry, Pusan National University, YangSan 676-870, Korea.
| | - So-Hyoun Lee
- Department of Prosthodontics, Dental Research Institute, School of Dentistry, Pusan National University, YangSan 676-870, Korea.
| | - Kyung Mi Shim
- Department of Veterinary Surgery, College of Veterinary Medicine, Chonnam National University, Gwangju 500-757, Korea.
| | - Se Eun Kim
- Department of Veterinary Surgery, College of Veterinary Medicine, Chonnam National University, Gwangju 500-757, Korea.
| | - Seong Soo Kang
- Department of Veterinary Surgery, College of Veterinary Medicine, Chonnam National University, Gwangju 500-757, Korea.
| | - Chang-Mo Jeong
- Department of Prosthodontics, Dental Research Institute, School of Dentistry, Pusan National University, YangSan 676-870, Korea.
| |
Collapse
|
49
|
Ahn SJ, Shin YM, Kim SE, Jeong SI, Jeong JO, Park JS, Gwon HJ, Seo DE, Nho YC, Kang SS, Kim CY, Huh JB, Lim YM. Characterization of hydroxyapatite-coated bacterial cellulose scaffold for bone tissue engineering. BIOTECHNOL BIOPROC E 2015. [DOI: 10.1007/s12257-015-0176-z] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
50
|
Kim SM, Choi JW, Jeon YC, Jeong CM, Yun MJ, Lee SH, Huh JB. Comparison of changes in retentive force of three stud attachments for implant overdentures. J Adv Prosthodont 2015; 7:303-11. [PMID: 26330977 PMCID: PMC4551786 DOI: 10.4047/jap.2015.7.4.303] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2015] [Revised: 05/11/2015] [Accepted: 05/12/2015] [Indexed: 11/08/2022] Open
Abstract
PURPOSE The aim of this study was to compare the changes in retentive force of stud attachments for implant overdentures by in vitro 2-year-wear simulation. MATERIALS AND METHODS Three commercially available attachment systems were investigated: Kerator blue, O-ring red, and EZ lock. Two implant fixtures were embedded in parallel in each custom base mounting. Five pairs of each attachment system were tested. A universal testing machine was used to measure the retentive force during 2500 insertion and removal cycles. Surface changes on the components were evaluated by scanning electron microscopy (SEM). A Kruskal-Wallis test, followed by Pairwise comparison, was used to compare the retentive force between the groups, and to determine groups that were significantly different (α<.05). RESULTS A comparison of the initial retentive force revealed the highest value for Kerator, followed by the O-ring and EZ lock attachments. However, no significant difference was detected between Kerator and O-ring (P>.05). After 2500 insertion and removal cycles, the highest retention loss was recorded for O-ring, and no significant difference between Kerator and EZ lock (P>.05). Also, Kerator showed the highest retentive force, followed by EZ lock and O-ring, after 2500 cycles (P<.05). Based on SEM analysis, the polymeric components in O-ring and Kerator were observed to exhibit surface wear and deformation. CONCLUSION After 2500 insertion and removal cycles, all attachments exhibited significant loss in retention. Mechanism of retention loss can only be partially explained by surface changes.
Collapse
Affiliation(s)
- Su-Min Kim
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jae-Won Choi
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Young-Chan Jeon
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Chang-Mo Jeong
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Mi-Jung Yun
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - So-Hyoun Lee
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| | - Jung-Bo Huh
- Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
| |
Collapse
|