1
|
Biomechanical comparison of composite and cadaveric humeri models in experiments on operated humeral shaft fractures. J Biomech 2024; 165:112017. [PMID: 38428374 DOI: 10.1016/j.jbiomech.2024.112017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2023] [Revised: 12/11/2023] [Accepted: 02/19/2024] [Indexed: 03/03/2024]
Abstract
A study was undertaken to determine how well contacting fracture fragments of composite bone replicated the behavior of fracture fragments in real bone. Ten composite and ten real humeral diaphyses were transected and reconstructed with limited-contact dynamic-compression plates. Two screws were placed on each side of the transection site and a calibrated electronic sensor sheet was placed between the imitated fracture fragments. After insertion of the distal screws, pressure measurements were made during insertion of the first proximal screw in compression mode, during insertion of the second screw in compression mode after loosening the first screw, and finally after retightening the first screw. The process was repeated after bending the plate. The contact area, the net compression force and the average compressive stress were computed and statistically compared. The composite bone and cadaveric bone differed in contact area and compressive stress but not in net compressive force. Plate bending did not produce a significant difference between composite and cadaveric bone. The results indicate that composite bone does not reproduce all the local fracture fragment conditions so that hardware testing in composite bone should proceed carefully. A gap between fracture fragments as is often used in comminuted fracture tests may remain as the most appropriate situation for fracture hardware testing.
Collapse
|
2
|
Relative contributions of the supraspinatus cord and strap tendons to shoulder abduction and translation. J Shoulder Elbow Surg 2024; 33:172-180. [PMID: 37543280 DOI: 10.1016/j.jse.2023.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 06/27/2023] [Accepted: 07/02/2023] [Indexed: 08/07/2023]
Abstract
BACKGROUND The supraspinatus (SS) is formed by a larger anterior bipennate muscle with a cord-like tendon and a posterior unipennate muscle with a strap-like tendon. There is a tendinous connection between the 2 SS subunits. Yet, the relative mechanical contribution of the SS cord and SS strap musculotendinous units to load transmission and subsequent shoulder abduction force is unknown. We hypothesized that a simulated SS cord vs. an SS strap tear would generate less shoulder abduction force and, further, an intact SS cord would offset the expected abduction loss from an SS strap tear, but the inverse would not be true. MATERIALS AND METHODS Twenty fresh-frozen cadaveric specimens were tested in a shoulder simulator with physiological load vectors applied to the upper and lower subscapularis, SS cord, SS strap, infraspinatus, and teres minor. The roles of the SS cord and SS strap muscles were delineated by varying their loads, while keeping constant loads on other muscles. The randomized testing trials included a native condition and 4 test cases that simulated tears by dropping the load and force transfer via the SS cord-to-SS strap connection by adding the load. Testing was completed at both 0° and 30° of abduction. During each test, shoulder abduction force, rotator cuff strains, and humeral translation were measured. RESULTS Simulated isolated SS cord and SS strap tears led to a significantly lower shoulder abduction force (P < .001). A simulated cord tear at 0° and 30° reduced the abduction force by 53% and 38%, respectively. A simulated strap tear at 0° and 30° dropped the abduction force by 27% and 23%, respectively. The decline in the abduction force was larger for the SS cord tear vs. SS strap tear (P ≤ .001). An SS cord tear with full-load transfer to the strap was able to recover to native values at both 0° and 30° (P ≥ .288). Likewise, an SS strap tear with full-load transfer to the SS cord showed a similar recovery to native values at both 0° and 30° (P ≥ .155). During full-load transfer, the tendon strain followed the loading pattern. An SS cord tear or SS strap tear did not cause a change in humeral translation (P ≥ .303). DISCUSSION The mechanical findings support the efficacy of nonoperative treatment of small (<10 mm) SS tears,11 because an intact SS strap tendon can effectively offset the abduction loss of a torn SS cord tear and vice versa.
Collapse
|
3
|
Biomechanical analysis of single-incision anatomic repair technique for distal biceps tendon rupture using tunneling device. Shoulder Elbow 2023; 15:195-206. [PMID: 37035614 PMCID: PMC10078820 DOI: 10.1177/17585732211034818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Accepted: 07/04/2021] [Indexed: 11/16/2022]
Abstract
Hypothesis Single-incision biceps tendon repair with an arthrotunneling device has previously been shown to be a safe and effective technique that provides the anatomic restoration of a two-incision approach and a reduced complication profile. This repair provides adequate and comparable fixation to repairs utilizing anchors, buttons, screws, etc., at a lower cost. Material and methods This study utilized 10 cadaveric specimens. Native and repair specimens were cyclically loaded and graft displacement, flexion/extension (FE) and pronation/supination (PS) moment arms at 12.5° to 152.5° (in 5° increments) before and after repair, and maximum load to failure were measured. Results The FE and PS moment arms and overall maximum moment arms were both significantly larger in the repaired case than in the native case (p < 0.01). Moment arms for supinated specimens were significantly greater than neutral specimens, which in turn was greater than pronated specimens (p < 0.01). The maximum load up to 10 mm of repair displacement was 214.5.0 ± 66.6 N and the repair displacement due to 1000 cycles of 50 N was 2.56 ± 2.06 mm. Conclusion The single-incision arthrotunneling technique is a safe and effective repair that recreates the anatomic footprint and biomechanics of the native biceps and has a reduced complication profile compared to a two-incision approach.
Collapse
|
4
|
Stability, deformity, and fixation of the floating shoulder: a cadaveric biomechanical study. J Shoulder Elbow Surg 2023; 32:519-525. [PMID: 36283563 DOI: 10.1016/j.jse.2022.09.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 09/18/2022] [Accepted: 09/28/2022] [Indexed: 11/05/2022]
Abstract
BACKGROUND Floating shoulder injuries cause instability and deformity due to disruptions of the scapula, clavicle, and superior shoulder suspensory complex ligaments (SSSC). Resulting deformity of the glenopolar angle (GPA) has not previously been established, nor has the impact on stability and deformity when surgical fixation is performed. This study sought to quantify stability and deformity for multiple injury patterns and the improvement to these parameters provided by clavicle and coracoclavicular (CC) ligament fixation. METHODS Fourteen cadaveric specimen upper extremities were used, which included the entire upper extremity, scapula, clavicle, and cranial-most ribs. After being mounted upright, a scapular neck fracture was created, followed by either a midshaft clavicle fracture or sectioning of the acromioclavicular and coracoacromial ligaments. Subsequent sectioning of the other structure(s) followed by the CC ligaments was then performed. In all specimens, the clavicle was then plated, followed by a CC ligament repair. At each step, a radiograph in the AP plane of the scapula was taken to measure GPA and displacement of the glenoid fragment using radiopaque markers placed in the scapula. These radiographs were taken both unloaded and with a 100-N applied medializing force. RESULTS When evaluating deformity related to sectioning, the GPA was reduced when the CC ligaments were sectioned compared to an isolated scapula fracture (P = .022) and compared to a combined scapula and clavicle fracture (P = .037). For stability, displacement with a 100-N force was significantly increased when the CC ligaments were sectioned compared to an isolated scapula fracture (P = .027). In cases of an ipsilateral scapula neck and clavicle fracture with intact ligaments, fixation of the clavicle alone provided a statistically significant improvement in the GPA (P = .002); but not in reduction of displacement (P = .061). In cases of an ipsilateral scapula neck and clavicle fracture with concomitant disruption of the coracoacromial, acromioclavicular, and CC ligaments, the GPA was improved by clavicle fixation (P < .001) and increasingly so by subsequent CC ligament repair (P < .001). Displacement was also improved in these 2 states (P < .001, P = .008, respectively). DISCUSSION This biomechanical study confirmed the importance of the acromioclavicular, coracoacromial, and CC ligaments in conferring stability in SSSC injuries. Disruption of the CC ligaments created significant deformity of the GPA and instability with a medializing force. Clinical treatment should consider the integrity of these ligaments and their repair in conjunction with clavicle fixation, knowing that this combination should restore a biomechanical state equivalent to an isolated scapula fracture.
Collapse
|
5
|
Shear wave elastography ultrasound does not quantify mechanical properties of the ulnar collateral ligament of the elbow. J Ultrasound 2023:10.1007/s40477-022-00768-y. [PMID: 36790657 DOI: 10.1007/s40477-022-00768-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2022] [Accepted: 12/19/2022] [Indexed: 02/16/2023] Open
Abstract
OBJECTIVE To validate shear wave elastography (SWE) stiffness measurements for the ulnar collateral ligament (UCL) of the elbow compared to mechanical measurements. MATERIALS AND METHODS Eleven fresh frozen human cadaveric upper extremities were evaluated by a musculoskeletal-specialized radiologist to provide SWE measurements used to calculate stiffness at 4 points along the anterior band of the UCL at various load states and flexion angles. Specimens were then dissected and optical markers were placed on the UCL to track displacement during applied force by a load frame, thereby providing measurements to calculate the mechanical stiffness. These two stiffness values were compared by ANOVA for all load states and flexion angles. RESULTS Measurements of stiffness by SWE for the UCL were three orders of magnitude smaller than the true mechanical testing stiffness and no correlations between SWE and mechanical measurements of stiffness were found at 30, 60 or 90 degrees of elbow flexion (R2 = 0.004, p = 0.85; R2 = 0.001, p = 0.92; R2 = 0.15, p = 0.24 respectively). SWE stiffness was greatest near the insertion of the ligament and lowest in the mid-substance of the ligament (p = 0.0002). CONCLUSIONS SWE stiffness did not correlate with mechanical measurements. Clinical utility of musculoskeletal SWE may be better defined when biomechanical properties or clinical outcomes can be correlated with SWE measurements. The ultimate clinical utility of SWE in musculoskeletal tissues may be qualitative, as demonstrated by differences throughout the length of the UCL in this study.
Collapse
|
6
|
The Pathoanatomy of Atraumatic Partial Distal Biceps Tears, A Cadaveric Study. JSES Int 2023. [DOI: 10.1016/j.jseint.2023.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
|
7
|
Biomechanical Analysis of Ideal Knee Flexion Angle for ACL Graft Tensioning Utilizing Multiple Femoral and Tibial Tunnel Locations. J Knee Surg 2023; 36:298-304. [PMID: 34327694 DOI: 10.1055/s-0041-1731826] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Anterior cruciate ligament (ACL) graft failure rate has been reported to be greater than 5% at 5 years. Our study evaluated ACL excursion with anatomic and nonanatomic femoral and tibial tunnels to determine optimal flexion angle to tension the ACL to minimize excursion. Ten cadaveric knee specimens were used. The ACL was sectioned and the femoral and tibial attachments were marked. A 1/16-inch drill created a tunnel in the center of the ACL footprint on the tibia and femur and additional tunnels were made 5 mm from this. A suture was passed through each tunnel combination and attached to a string potentiometer. The knee was ranged from full extension to 120 degrees of flexion for 10 cycles while mounted in a custom fixture. The change in length (excursion) of the suture during movement was recorded for each combination of femoral and tibial tunnels. Anatomic reconstruction of the ACL with tunnel placement in the center of the femoral and tibial footprint did not result in an isometric graft, with excursion of the ACL during knee motion of 7.46 mm (standard deviation [SD]: 2.7mm), greatest at 2.84 degrees of flexion (SD: 4.22). The tunnel combination that resulted in the least excursion was a femoral footprint 5 mm anterior to the femoral and 5 mm posterior to the tibial footprint (4. 2mm, SD: 1.37 mm). The tunnel combination that resulted in the most excursion utilized femoral footprint 5 mm proximal to the femoral and 5 mm posterior to the tibial footprint (9.81 mm, SD: 2.68 mm). Anatomic ACL reconstruction results in significant excursion of the ACL throughout motion. If not tensioned properly, the ACL can stretch during range of motion, potentially leading to rerupture. To prevent stretching of the graft, the current biomechanical study recommends tensioning an anatomic ACL reconstruction at its point of maximal excursion, or between 0 and 5 degrees of flexion. The level of evidence is IV.
Collapse
|
8
|
National audit of non-melanoma skin cancer excisions performed by plastic surgery in the UK. Br J Surg 2022; 109:1040-1043. [DOI: 10.1093/bjs/znac232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 05/30/2022] [Indexed: 11/13/2022]
Abstract
A national, multi-centre audit of non-melanoma skin cancer excisions by plastic surgery.
Collapse
|
9
|
Pronation on weightbearing radiographs does not correlate with pronation from weightbearing CT scans. Foot Ankle Surg 2022; 28:763-769. [PMID: 34674938 DOI: 10.1016/j.fas.2021.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2021] [Revised: 08/16/2021] [Accepted: 10/06/2021] [Indexed: 02/04/2023]
Abstract
INTRODUCTION In hallux valgus (HV), first metatarsal pronation is increasingly recognized as an important aspect of the deformity. The purpose of this study was to compare pronation in HV patients determined from the shape of the lateral head of the first metatarsal on AP weightbearing radiographs with pronation calculated from weightbearing CT (WBCT) scans. METHODS Patients were included in this study if they had preoperative and 5-month postoperative WBCT scans and corresponding weightbearing AP radiographs of the affected foot. Pronation of the first metatarsal on WBCT scans was measured using a 3D CAD model and the alpha angle and categorized into four groups on radiographs. Association between pronation groups on radiographs and WBCT scans was determined using Spearman correlation coefficients (rs) and by comparing mean WBCT pronation of the first metatarsal between plain radiograph pronation groups. RESULTS Agreement between the two observers' pronation on radiographs was good (k = 0.634) and moderate (k = 0.501), respectively. There was no correlation between radiographic pronation and the 3D CAD model (rs < 0.15). Preoperatively, there was weak correlation between the alpha angle and the radiographic pronation groups (rs = 0.371, P = 0.048) although this relationship did not hold postoperatively (rs = 0.330, P = 0.081). There was no difference in mean pronation calculated on WBCT scans between the plain radiographic groups. CONCLUSION Pronation of the first metatarsal measured on weightbearing AP radiographs had moderate interobserver agreement and was only weakly associated with pronation measured from WBCT scans. These results suggest that first metatarsal pronation measured on weightbearing radiographs is not a substitute for pronation measured on WBCT scans. LEVEL OF EVIDENCE III, retrospective cohort study.
Collapse
|
10
|
Does operative treatment of geriatric pelvic ring injuries lead to a high risk of one-year mortality? Injury 2021; 52:2973-2977. [PMID: 34246482 DOI: 10.1016/j.injury.2021.06.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Accepted: 06/26/2021] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Non-operative management of pelvic ring injuries in the elderly is associated with a high risk of one-year mortality. The majority of these injuries are the result of a low-energy mechanism, however, due to the multiple medical comorbidities in this patient population the injuries are associated with a high degree of morbidity. The purpose of this study was to determine the one-year mortality risk after operative treatment of pelvic ring injuries in a geriatric patient population and the effect of patient and injury characteristics on the risk of mortality. PATIENTS AND METHODS We performed a retrospective review of patients over the age of 70 who underwent operative fixation of a pelvic ring injury at two Level 1 trauma centers between January 2016 and June 2019. Medical records were reviewed for patient and injury characteristics including: Charlson Comorbidity Index (CCI), American Society of Anesthesiologists (ASA) physical status score or Injury Severity Score (ISS), hospital and intensive care unit (ICU) length of stay (LOS). The primary outcome of interest was the one-year mortality risk following operative treatment. Secondary outcomes included the effect of patient and injury characteristics on the one-year mortality risk and the hospital LOS. RESULTS Ninety patients were included with an average age of 79.8 ± 6.5 years. The overall mortality was 8.9% (n = 8) and was significantly associated with the CCI. There was no significant effect related to the ASA physical status score or ISS. The average hospital LOS was 9.2 ± 7.3 days and was associated with the CCI, ASA physical status score, and ISS. DISCUSSION Non-operative management of pelvic ring injuries in geriatric patients is associated with a high risk of one-year mortality. Our findings suggest operative treatment of these fractures is associated with an acceptable risk of one-year mortality that falls below the commonly reported range for non-operatively managed injuries. Furthermore, the risk of mortality was significantly associated with the patient's pre-injury state as determined by the CCI.
Collapse
|
11
|
Fibrin Glue and Conduit Form a Composite Structure in Digital Nerve Repair. J Biomech Eng 2021; 144:1115775. [PMID: 34382652 DOI: 10.1115/1.4052110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Indexed: 11/08/2022]
Abstract
Repair of severed nerves without auto- or allograft has included suture, suture with glue alone, suture with conduit and suture with glue augmentation to conduit, where use of conduit is considered for separation of the nerve ends from 5mm to 3cm. Repairs must not only serve acutely to provide apposition of nerve ends but must enable the healing of the nerve. Using biological conduit can place suture at the ends of the conduit while fibrin glue alone eliminates suture but with limited strength. The combination of conduit and glue offers the growth guidance of conduit with sufficient strength from the glue to maintain the nerve within the conduit. The role of glue in the repair integrity remains an open question, however. We sought to determine the factors in the strength of a glue-conduit-nerve construct and include consideration of standard suture repair. Fresh-frozen cadaveric digital nerves were repaired with suture alone, with glue alone or with suture and glue together and loaded to failure. Previously tested specimens with conduit, suture and glue were considered for comparison. The suture alone (2.02N) and suture with glue (2.24N) were not statistically different from each other but were statistically stronger than glue alone (0.15N). Compared to the earlier results of the strength of conduit with glue (0.65N), these results show that the glue and conduit act together. The increased area over which the glue adheres to the nerve and conduit creates a composite structure stronger than either alone.
Collapse
|
12
|
Correlation of Different Methods of Measuring Pronation of the First Metatarsal on Weightbearing CT Scans. Foot Ankle Int 2021; 42:1049-1059. [PMID: 33797279 DOI: 10.1177/10711007211003090] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND There is no consensus in the foot and ankle literature regarding how to measure pronation of the first metatarsal in patients with hallux valgus. The primary purpose of this study was to compare 2 previously published methods for measuring pronation of the first metatarsal and a novel 3-dimensional measurement of pronation to determine if different measurements of pronation are associated with each other. METHODS Thirty patients who underwent a modified Lapidus procedure for their hallux valgus deformity were included in this study. Pronation of the first metatarsal was measured on weightbearing computed tomography (WBCT) scans using the α angle with reference to the floor, a 3-dimensional computer-aided design (3D CAD) calculation with reference to the second metatarsal, and a novel method, called the triplanar angle of pronation (TAP), that included references to both the floor (floor TAP) and base of the second metatarsal (second TAP). Pearson's correlation coefficients were used to determine if the 3 calculated angles of pronation correlated to each other. RESULTS Preoperative and postoperative α angle and 3D CAD had no correlation with each other (r = 0.094, P = .626 and r = 0.076, P = .694, respectively). Preoperative and postoperative second TAP and 3D CAD also had no correlation (r = 0.095, P = .624 and r = 0.320, P = .09, respectively). However, preoperative and postoperative floor TAP and α angle were found to have moderate correlations (r = 0.595, P = .001 and r = 0.501, P = .005, respectively). CONCLUSION The calculation of first metatarsal pronation is affected by the reference and technique used, and further work is needed to establish a consistent measurement for the foot and ankle community. LEVEL OF EVIDENCE Level III, retrospective cohort study.
Collapse
|
13
|
Locating the rotator cable during subacromial arthroscopy: bursal- and articular-sided anatomy. J Shoulder Elbow Surg 2021; 30:S57-S65. [PMID: 33878486 DOI: 10.1016/j.jse.2021.03.148] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2020] [Revised: 03/21/2021] [Accepted: 03/28/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND The rotator cable (RCa) is an important articular-sided structure of the cuff capsular complex that helps prevent suture pull out during rotator cuff repairs (RCRs) and plays a role in force transmission. Yet, the RCa cannot be located during bursal-sided RCRs. The purpose of this study is to develop a method to locate the RCa in the subacromial space and compare its bursal- and articular-sided dimensions. METHODS In 20 fresh-frozen cadaveric specimens, the RCa was found from the articular side, outlined with stitches, and then evaluated from the bursal side using an easily identifiable reference point, the intersection of a line bisecting the supraspinatus (SS) tendon and posterior SS myotendinous junction (MTJ). Four bursal-sided lengths were measured on the SS-bisecting line as well as the RCa's outside anteroposterior base. For the articular-sided measurements, the rotator cuff capsular complex was detached from bone and optically scanned creating 3D solid models. Using the 3D models, 4 articular-sided lengths were made, including the RCa's inside and outside anteroposterior base. RESULTS The RCa's medial arch was located 9.9 ± 5.6 mm from the reference point in 10 intact specimens and 4.1 ± 2.4 mm in 10 torn specimens (P = .007). The RCa's width was 10.9 ± 2.1 mm, and the distance from the lateral edge of the RCa to the lateral SS insertion was 13.9 ± 4.8 mm. The bursal- and articular-sided outside anteroposterior base measured 48.1 ± 6.4 mm and 49.6 ± 6.5 mm, respectively (P = .268). The average inside anteroposterior base measurement was 37.3 ± 5.9 mm. DISCUSSION The medial arch of the RCa can be reliably located during subacromial arthroscopy using the reference point, analogous to the posterior SS MTJ. The RCa is located 10 mm in intact and 4 mm in torn tendons (P = .007) from the posterior SS MTJ. If the above 6-mm shift in location of the RCa is not taken into consideration during rotator cuff suture placement, it could negatively affect time zero repair strength. The inside anteroposterior base of the RCa measures on average 37 mm; therefore, rotator cuff tears measuring >37 mm are at risk of rupturing part or all of the RCa's 2 humeral attachments, which if not recognized and addressed could impact postoperative function.
Collapse
|
14
|
A simple foot pedal device in a horizontal bore imaging facility replicates weightbearing outcomes for Hallux Valgus patients. Foot Ankle Surg 2020; 26:320-324. [PMID: 31079958 DOI: 10.1016/j.fas.2019.04.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 03/08/2019] [Accepted: 04/09/2019] [Indexed: 02/04/2023]
Abstract
BACKGROUND Weightbearing images are important to the diagnosis of foot pathologies as are the three dimensional views available from CT and MRI. Standard three-dimensional imaging hardware, however, does not have a simple tool to obtain weightbearing images. The current research aimed to design, build and test a simple device to apply load in a horizontal bore imaging facility. METHODS With the immediate need in hallux valgus studies, hallux valgus subjects were imaged using the new loading device, which could be easily transported and had no additional electronics. RESULTS Testing showed that the usual angular measures of the foot (intermetatarsal and hallux valgus) replicated the results from the standard of care standing plain film results. With application of load, HV angle changed from 29.9° non-weightbearing to 32.2° weightbearing, while IM angle changed from nonweightbearing 15.8° to weightbearing 16.5°. CONCLUSION The pedal-like device can provide weightbearing images in a horizontal bore MRI facility.
Collapse
|
15
|
Abstract
BACKGROUND Hallux valgus (HV) is a triplanar deformity of the first ray including pronation of the first metatarsal with subluxation of the sesamoids. The purpose of this study was to investigate if a first tarsometatarsal fusion (modified Lapidus technique), without preoperative knowledge of pronation measured on weightbearing computed tomographic (CT) scans, changed pronation of the first metatarsal and determine if reduction of the sesamoids was correlated with changes in first metatarsal pronation. METHODS Thirty-one feet in 31 patients with HV who underwent a modified Lapidus procedure had preoperative and at least 5-month postoperative weightbearing CT scans and radiographs. Differences in preoperative and postoperative pronation of the first metatarsal using a 3-dimensional computer-aided design, HV angle, and intermetatarsal angle (IMA) were calculated using Wilcoxon signed-rank tests. After dividing patients into groups based on sesamoid station, Kruskal-Wallis H tests were used to compare first metatarsal pronation between the groups. RESULTS The mean preoperative and postoperative pronation of the first metatarsal was 29.0 degrees (range 15.8-51.1, SD 8.7) and 20.2 degrees (range 10.4-32.6, SD 5.4), respectively, which was a mean change in pronation of the first ray of -8.8 degrees (P < .001). There was no difference in pronation of the first ray when stratified by postoperative sesamoid position (P > .250). The average preoperative and postoperative IMA was 16.7 degrees (SD 3.2) and 8.8 degrees (SD 2.8), which demonstrated a significant change (P < .001). CONCLUSIONS The modified Lapidus procedure was an effective tool to change pronation of the first ray. Reduction of the sesamoids was not associated with postoperative first metatarsal pronation. LEVEL OF EVIDENCE Level IV, case series.
Collapse
|
16
|
Abstract
Background: Outcomes following digital nerve repair are suboptimal despite much research and various methods of repair. Increased tensile strength of the repair and decreased suture material at the repair site may be 2 methods of improving biologic and biomechanical outcomes, and conduit-assisted repair can aid in achieving both of these goals. Methods: Ninety-nine fresh-frozen digital nerves were equally divided into 11 different groups. Each group uses a different combination of number of sutures at the coaptation site and number of sutures at each end of the nerve-conduit junction, as well as 2 calibers of nylon suture. Nerves were transected, repaired with these various suture configurations using an AxoGuard conduit, and loaded to failure. Results: The 2-way analysis of variance (ANOVA) showed that repairs performed with 8-0 suture have significantly higher maximum failure load compared with 9-0 suture repairs (P < .01). Increasing the number of sutures in the repair significantly increased the maximum failure load in all groups regardless of suture caliber used (P < .01). Repairs with 9-0 suture at the coaptation site did not jeopardize repair strength when compared with 8-0 suture. Conclusions: Conduit-assisted primary digital nerve repairs with 8-0 suture increases the maximum load to failure compared with repairs with 9-0 suture, as does increasing the overall number of sutures. Using 9-0 suture at the coaptation site with 8-0 suture at the nerve-conduit junction does not jeopardize tensile strength when compared with similar repairs using all 8-0 suture and may decrease inflammation at the repair site while still achieving sufficient tensile strength.
Collapse
|
17
|
Abstract
Background The distal biceps tendon externally rotates from proximal to distal before inserting onto the radius. Our hypothesis is that an externally rotated (anatomic) repair would re-create native supination moment arm and flexion force, whereas an internally rotated (nonanatomic) repair would result in reduced force transmission. Methods The mechanical tests performed in this study measured isometric moment arms and elbow flexion force using a validated elbow simulator as previously published. Mechanical testing was performed on 8 native cadaveric elbows (61 ± 15 years). The distal biceps tendons in all specimens were then incised from their footprint and repaired with anatomic and nonanatomic tendon rotations. After each repair, the specimens were retested. The repair sequence was randomly assigned. Results Gross observation showed repair site bunching with the nonanatomic repairs. There was no statistical difference in the moment arms between the native, anatomic, and nonanatomic rotations for the 3 forearm angles (P ≥ .352). Analysis showed no statistical difference in flexion force ratio for the elbow at 90° (P ≥ .283). Discussion The study showed that biceps tendon rotation does not play a role in supination moment arm or flexion force. Twisting the distal biceps tendon around the tendon axis does not change the direction of its applied force on the tuberosity. Tendon bunching in nonanatomic reattachments increases repair site width, which may lead to tendon-ulnar impingement during forearm rotation.
Collapse
|
18
|
No Difference in Outcomes Detected Between Decellular Nerve Allograft and Cable Autograft in Rat Sciatic Nerve Defects. J Bone Joint Surg Am 2019; 101:e42. [PMID: 31094986 DOI: 10.2106/jbjs.18.00417] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Nerve injuries with a gap/defect represent a clinical challenge without a clear solution. Reconstruction with cable autografts is a common treatment technique, and repair with decellular nerve allograft is a newer option. The purpose of this study was to compare the functional outcomes of reconstruction with cable autografts with those of matched-diameter decellular nerve allografts to evaluate the relative importance of diameter as well as the autograft-versus-allograft nature of the reconstruction. METHODS A unilateral 10-mm sciatic nerve defect was created in 81 genetically identical male Lewis rats and then repaired with a reverse autograft, 4 or 5 sural nerve cable autografts, or a matched-diameter decellular nerve allograft. In each group, at each time point (12, 16, and 20 weeks), all 9 animals underwent functional testing and 5 of the 9 underwent histologic analysis. Functional testing included bilateral measurements of the isometric tetanic force of the tibialis anterior (primary outcome), the weight of the tibialis anterior, and the gastrocnemius compound muscle action potential (CMAP) latency. Histologic evaluation included an axon count as well as measurement of the axon density, fiber diameter, myelin thickness, and G-ratio. RESULTS The repair groups did not differ significantly in terms of isometric tetanic force, muscle weight, or CMAP latency, but these measurements did differ significantly according to the time after surgery (p < 0.05). The isometric tetanic force percent recovery (width of the 95% confidence interval) for the reverse autograft, cable autograft, and decellular nerve allograft was 57.7% (15.6%), 57.0% (23.4%), and 56.0% (19.7%), respectively, at 12 weeks; 69.1% (14.7%), 65.6% (18.5%), and 65.9% (29.1%) at 16 weeks; and 72.5% (18.2%), 73.7% (25.6%), and 71.8% (22.4%) at 20 weeks. Isometric tetanic force and muscle weight recovery were greater and CMAP latency was shorter at 20 and 16 weeks after surgery than they were at 12 weeks. The treatment type did not affect any of the histologic outcomes. CONCLUSIONS In this animal study, we found that matched-diameter decellular nerve allograft was not significantly different from reverse autograft or cable graft reconstruction in terms of function and histologic outcomes. These findings support decellular nerve allograft as a viable treatment option for nerve reconstruction. CLINICAL RELEVANCE This study showed that decellular nerve allograft was no different from cable or reverse autograft in terms of outcome measures in a rat sciatic nerve defect model. If these results are applicable clinically, it would obviate the need for autograft nerve harvest and its ensuing donor site morbidity.
Collapse
|
19
|
Evaluation of bacterial presence on lead X-ray aprons utilised in the operating room via IBIS and standard culture methods. J Infect Prev 2019; 20:191-196. [PMID: 31428200 DOI: 10.1177/1757177419833163] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2018] [Accepted: 11/04/2018] [Indexed: 11/17/2022] Open
Abstract
Background Despite precautions, surgical procedures carry risk of infection. Radiation-protective lead aprons worn by operating personnel are a potential source of bacterial contamination and have not been fully evaluated. Aim/objective To evaluate lead aprons as a source of bacterial contamination, identify organisms most commonly found on this source, and devise a method with which to lower the risk of contamination. Methods In this basic science study, 20 randomly selected lead X-ray aprons were swabbed at three time points. The experimental treatment was with a hospital-grade disinfectant wipe. The samples were assessed for bacterial growth via traditional plating methods and mass spectrometry. Plates were graded on a scale of 0 to 4+ based on the number of quadrants with growth. Growth on one quadrant or more was considered contaminated. Findings/results Bacteria were initially detected via IBIS on a majority of the aprons (32/40), most commonly Staphylococcus epidermidis and Propionibacterium acnes. Virulent organisms cultured were Methicillin-resistant Staphylococcus epidermidis (MRSE), Neisseria, Streptococcus viridans and pseudomonas. MRSE were detected on 5/20 of the samples. Immediately after treatment, the majority of aprons showed less bacterial contamination (0/20 standard culture positive; 13/20 IBIS positive) with some recurrence at the 6-h time point (2/20 standard culture positive, 16/20 IBIS positive). All MRSE detected initially was eradicated. Discussion Lead X-ray aprons worn in the operating room harbour bacteria. Disinfecting before use may prevent the introduction of virulent organisms to patients. Our proposed method of sanitising with a disinfectant wipe is quick and effective.
Collapse
|
20
|
Osteoconductive Enhancement of Polyether Ether Ketone: A Mild Covalent Surface Modification Approach. ACS APPLIED BIO MATERIALS 2018; 1:1047-1055. [DOI: 10.1021/acsabm.8b00274] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
21
|
Abstract
BACKGROUND The aim of the study was to compare biomechanical strength, repair times, and repair values for zone II core flexor tendon repairs. METHODS A total of 75 fresh-frozen human cadaveric flexor tendons were harvested from the index through small finger and randomized into one of 5 repair groups: 4-stranded cross-stitch cruciate (4-0 polyester and 4-0 braided suture), 4-stranded double Pennington (2-0 knotless barbed suture), 4-stranded Pennington (4-0 double-stranded braided suture), and 6-stranded modified Lim-Tsai (4-0 looped braided suture). Repairs were measured in situ and their repair times were measured. Tendons were linearly loaded to failure and multiple biomechanical values were measured. The repair value was calculated based on operating room costs, repair times, and suture costs. Analysis of variance (ANOVA) and Tukey post hoc statistical analysis were used to compare repair data. RESULTS The braided cruciate was the strongest repair ( P > .05) but the slowest ( P > .05), and the 4-stranded Pennington using double-stranded suture was the fastest ( P > .05) to perform. The total repair value was the highest for braided cruciate ( P > .05) compared with all other repairs. Barbed suture did not outperform any repairs in any categories. CONCLUSIONS The braided cruciate was the strongest of the tested flexor tendon repairs. The 2-mm gapping and maximum load to failure for this repair approached similar historical strength of other 6- and 8-stranded repairs. In this study, suture cost was negligible in the overall repair cost and should be not a determining factor in choosing a repair.
Collapse
|
22
|
Abstract
BACKGROUND An ideal peripheral nerve repair construct does not currently exist. Our primary goal was to determine whether fibrin glue adds to the tensile strength of conduit-assisted primary digital nerve repairs. Our secondary goal was to evaluate the impact of varying suture number and location on the tensile strength. METHODS Ninety cadaveric digital nerves were harvested and divided equally into the following repair groups: A (4/4), B (2/2), C (0/2), D (0/1), and E (0/0) with the first number referring to the number of sutures at the coaptation and the second number referring to the number of sutures at each proximal and distal end of the nerve-conduit junction. When fibrin glue was added, the group was labeled prime. The nerve specimens were transected and then repaired with 8-0 nylon suture and conduit. The tensile strength of the repairs was tested, and maximum failure load was determined. The results were analyzed with a 2-way analysis of variance. The Tukey post hoc test compared repair groups if the 2-way analysis of variance showed significance. RESULTS Both suture group and glue presence significantly affected the maximum failure load. Increasing the number of sutures increased the maximum failure load, and the presence of fibrin glue also increased the failure load. CONCLUSIONS Fibrin glue was found to increase the strength of conduit-assisted primary digital nerve repairs. Furthermore, the number of sutures correlated to the strength of the repair. Fibrin glue may be added to a conduit-assisted primary digital nerve repair to maintain strength and allow fewer sutures at the primary coaptation site.
Collapse
|
23
|
Weight-bearing recommendations after first metatarsophalangeal joint arthrodesis fixation: a biomechanical comparison. J Orthop Surg Res 2017; 12:23. [PMID: 28166805 PMCID: PMC5294903 DOI: 10.1186/s13018-017-0525-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Accepted: 01/23/2017] [Indexed: 11/25/2022] Open
Abstract
Background This study sought to determine whether several metatarsophalangeal (MTP) fusion techniques require complete immobilization or if some level of weight-bearing could be recommended after surgery. A comparison of synthetic composite to actual bone was included in order to examine the validity of the testing conditions. Methods Four MTP fusion modalities were tested in synthetic composite bone models: unlocked plating, locked plating, crossed lag screws, and an unlocked plate with a single lag screw. Stiffness was calculated and then used to find the two most rigid constructs; the load to failure was recorded. Stiffness and load to failure testing for the two more rigid constructs in paired cadaveric bones were followed. Results The unlocked plate plus screw and crossed screw constructs were stiffest (p < 0.008). Loads to failure of the unlocked plate plus screw and crossed screws in synthetic bone were 131 and 101 N, respectively and in cadaveric bone were 154 and 94 N, respectively, which are less than the estimated 25% body weight required at the MTP joint. The plate plus screws were statistically more stiff than crossed screws (p = 0.008), but there was no statistical difference between synthetic and cadaveric bone in load to failure (p = 0.296). Conclusions The plate plus screw offered the greatest stiffness; the failure test showed that no construct could withstand weight-bearing as tolerated; and, synthetic composite models of the MTP joint did not provide the consistent results in stiffness and failure.
Collapse
|
24
|
Open-label, randomized study of individualized, pharmacokinetically (PK)-guided dosing of paclitaxel combined with carboplatin or cisplatin in patients with advanced non-small-cell lung cancer (NSCLC). Ann Oncol 2016; 27:1895-902. [PMID: 27502710 DOI: 10.1093/annonc/mdw290] [Citation(s) in RCA: 62] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2016] [Accepted: 07/14/2016] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND Variable chemotherapy exposure may cause toxicity or lack of efficacy. This study was initiated to validate pharmacokinetically (PK)-guided paclitaxel dosing in patients with advanced non-small-cell lung cancer (NSCLC) to avoid supra- or subtherapeutic exposure. PATIENTS AND METHODS Patients with newly diagnosed, advanced NSCLC were randomly assigned to receive up to 6 cycles of 3-weekly carboplatin AUC 6 or cisplatin 80 mg/m(2) either with standard paclitaxel at 200 mg/m(2) (arm A) or PK-guided dosing of paclitaxel (arm B). In arm B, initial paclitaxel dose was adjusted to body surface area, age, sex, and subsequent doses were guided by neutropenia and previous-cycle paclitaxel exposure [time above a plasma concentration of 0.05 µM (Tc>0.05)] determined from a single blood sample on day 2. The primary end point was grade 4 neutropenia; secondary end points included neuropathy, radiological response, progression-free survival (PFS) and overall survival (OS). RESULTS Among 365 patients randomly assigned, grade 4 neutropenia was similar in both arms (19% versus 16%; P = 0.10). Neuropathy grade ≥2 (38% versus 23%, P < 0.001) and grade ≥3 (9% versus 2%, P < 0.001) was significantly lower in arm B, independent of the platinum drug used. The median final paclitaxel dose was significantly lower in arm B (199 versus 150 mg/m(2), P < 0.001). Response rate was similar in arms A and B (31% versus 27%, P = 0.405), as was adjusted median PFS [5.5 versus 4.9 months, hazard ratio (HR) 1.16, 95% confidence interval (CI) 0.91-1.49, P = 0.228] and OS (10.1 versus 9.5 months, HR 1.05, 95% CI 0.81-1.37, P = 0.682). CONCLUSION PK-guided dosing of paclitaxel does not improve severe neutropenia, but reduces paclitaxel-associated neuropathy and thereby improves the benefit-risk profile in patients with advanced NSCLC. CLINICAL TRIAL INFORMATION NCT01326767 (https://clinicaltrials.gov/ct2/show/NCT01326767).
Collapse
|
25
|
Reducing Escherichia coli growth on a composite biomaterial by a surface immobilized antimicrobial peptide. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 65:126-34. [PMID: 27157735 DOI: 10.1016/j.msec.2016.04.021] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2015] [Revised: 03/22/2016] [Accepted: 04/06/2016] [Indexed: 10/22/2022]
Abstract
A new composite bioceramic consisting of calcium aluminum oxide (CaAlO) and hydroxyapatite (HA) was functionalized with the synthetic antimicrobial peptide Inverso-CysHHC10. CaAlO is a bioceramic that can be mold cast easily and quickly at room temperature. Improved functionality was previously achieved through surface reactions. Here, composites containing 0-5% HA (by mass) were prepared and the elastic modulus and modulus of rupture were mechanically similar to non-load bearing bone. The addition of hydroxyapatite resulted in increased osteoblast attachment (>180%) and proliferation (>140%) on all composites compared to 100% CaAlO. Antimicrobial peptide (AMP) immobilization was achieved using an interfacial alkene-thiol click reaction. The linked AMP persisted on the composite (>99.6% after 24h) and retained its activity against Escherichia coli based on N-phenylnaphthylamine uptake and bacterial turbidity tests. Overall, this simple scaffold system improves osteoblast activity and reduces bacterial activity.
Collapse
|
26
|
Computational study of human head response to primary blast waves of five levels from three directions. PLoS One 2014; 9:e113264. [PMID: 25409326 PMCID: PMC4237386 DOI: 10.1371/journal.pone.0113264] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2014] [Accepted: 10/02/2014] [Indexed: 11/17/2022] Open
Abstract
Human exposure to blast waves without any fragment impacts can still result in primary blast-induced traumatic brain injury (bTBI). To investigate the mechanical response of human brain to primary blast waves and to identify the injury mechanisms of bTBI, a three-dimensional finite element head model consisting of the scalp, skull, cerebrospinal fluid, nasal cavity, and brain was developed from the imaging data set of a human female. The finite element head model was partially validated and was subjected to the blast waves of five blast intensities from the anterior, right lateral, and posterior directions at a stand-off distance of one meter from the detonation center. Simulation results show that the blast wave directly transmits into the head and causes a pressure wave propagating through the brain tissue. Intracranial pressure (ICP) is predicted to have the highest magnitude from a posterior blast wave in comparison with a blast wave from any of the other two directions with same blast intensity. The brain model predicts higher positive pressure at the site proximal to blast wave than that at the distal site. The intracranial pressure wave invariably travels into the posterior fossa and vertebral column, causing high pressures in these regions. The severities of cerebral contusions at different cerebral locations are estimated using an ICP based injury criterion. Von Mises stress prevails in the cortex with a much higher magnitude than in the internal parenchyma. According to an axonal injury criterion based on von Mises stress, axonal injury is not predicted to be a cause of primary brain injury from blasts.
Collapse
|
27
|
Relationship among circulating tumor cells, CEA and overall survival in patients with metastatic colorectal cancer. Ann Oncol 2013; 24:420-428. [PMID: 23028040 DOI: 10.1093/annonc/mds336] [Citation(s) in RCA: 125] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
BACKGROUND We previously reported results of a prospective trial evaluating the significance of circulating tumor cells (CTCs) in patients with metastatic colorectal cancer (mCRC). This secondary analysis assessed the relationship of the CTC number with carcinoembryonic antigen (CEA) and overall survival. PATIENTS AND METHODS Patients with mCRC had CTCs measured at baseline and specific time points after the initiation of new therapy. Patients with a baseline CEA value ≥ 10 ng/ml and CEA measurements within ± 30 days of the CTC collection were included. RESULTS We included 217 patients with mCRC who had a CEA value of ≥ 10 ng/ml. Increased baseline CEA was associated with shorter survival (15.8 versus 20.7 months, P = 0.012). Among all patients with a baseline CEA value of ≥ 25 ng/ml, patients with low baseline CTCs (<3, n = 99) had longer survival than those with high CTCs (≥ 3, n = 58; 20.8 versus 11.7 months, P = 0.001). CTCs added prognostic information at the 3-5- and 6-12-week time points regardless of CEA. In a multivariate analysis, CTCs at baseline but not CEA independently predicted survival and both CTCs and CEA independently predicted survival at 6-12 weeks. CONCLUSIONS This study demonstrates that both CEA and CTCs contribute prognostic information for patients with mCRC.
Collapse
|
28
|
The contracted elbow: is ulnar nerve release necessary? J Shoulder Elbow Surg 2012; 21:1632-6. [PMID: 22743068 DOI: 10.1016/j.jse.2012.04.007] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2011] [Revised: 03/13/2012] [Accepted: 04/01/2012] [Indexed: 02/01/2023]
Abstract
BACKGROUND Prophylactic release of the ulnar nerve in patients undergoing capsular release for severe elbow contractures has been recommended, although there are limited data to support this recommendation. Our hypothesis was that more severely limited preoperative flexion and extension would be associated with a higher incidence of postoperative ulnar nerve symptoms in patients undergoing capsular release. MATERIALS AND METHODS We conducted a retrospective review of 164 consecutive patients who underwent open or arthroscopic elbow capsular release for stiffness between 2003 and 2010. The ulnar nerve was decompressed if the patient had preoperative ulnar nerve symptoms or a positive Tinel test. Preoperative and postoperative range of motion and incidence of ulnar nerve symptoms were recorded. RESULTS The mean improvement in the arc of motion of was 36.7°. New-onset postoperative ulnar nerve symptoms developed in 7 of 87 patients (8.1%) who did not undergo ulnar nerve decompression; eventually, 5 of these patients with persistent symptoms underwent ulnar nerve decompression. The rate of developing postoperative symptoms was higher if patients had preoperative flexion ≤ 100° (15.2%) compared with those with preoperative flexion >100° (3.7%). There was no association between preoperative extension or gain in motion arc and postoperative symptoms. CONCLUSIONS The overall rate of ulnar nerve symptoms after elbow contracture release was low if ulnar nerve decompression was performed in patients with preoperative symptoms or a positive Tinel test. There was a higher rate of ulnar nerve symptoms in patients with more severe contractures (≤ 100° of preoperative flexion), which did not reach statistical significance.
Collapse
|
29
|
Design and implementation of a multichannel millimeter wave interferometer for the Compact Toroidal Hybrid experiment. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2012; 83:10E332. [PMID: 23126990 DOI: 10.1063/1.4732056] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
A three-channel 1 mm wave interferometer has been designed, assembled, and installed on the Compact Toroidal Hybrid torsatron (CTH). The interferometer design makes novel use of a subharmonic mixer for detection, which simplifies alignment. It employs a single electronically tunable source that is repetitively chirped using a sawtooth waveform of frequency up to 1 MHz. The 15.25 GHz drive oscillator is multiplied in two stages to 122 GHz before a final doubler stage brings it to 244 GHz. Local oscillator (LO) power at 122 GHz is directed through waveguide to the LO input of the subharmonic mixer of each viewing chord, simplifying alignment. Phase detection is performed by directly digitizing the amplified mixer outputs at 50 MHz and processing them with a software algorithm. Initial measurements made with the central chord of the new interferometer agree with those from the existing 4 mm system at low densities. The 1 mm system performs well in current-driven discharges reaching densities over 10(19) m(-3), whereas the lower frequency interferometer is found to be less reliable due to loss of fringes. This is a critical improvement for experiments studying the onset, avoidance, and vacuum magnetic transform dependence of disruptions in the CTH device.
Collapse
|
30
|
Intraosseous hemangioma of the clivus: a case report and review of the literature. J Neurosurg Sci 2012; 56:255-259. [PMID: 22854594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Intraosseous hemangiomas are benign vascular tumors that are encountered most commonly in vertebrae and rarely in the skull. When presenting in the skull, they are commonly found in the calvarium in frontal and parietal bones and seldom in the skull base. We encountered a patient with an incidental finding on magnetic resonance imaging (MRI) of an enhancing lesion in the clivus. Here we report an unusual location of a clival intraosseous hemangioma. A 62 year old man worked up for carpal tunnel syndrome had imaging of his cervical spine that revealed an enhancing clival lesion, which extended into the left occipital condyle. Endoscopic endonasal biopsy was performed on the abnormality revealing a capillary hemangioma. Patient tolerated the biopsy well and no further surgical intervention is indicated at this time. Patient will be followed at six month intervals. Primary intraosseus hemangiomas of the skull are extremely rare and usually occur in the calvarium. This is one of the few reported case of an intraosseus hemangioma in the clivus. We present this case in part because it is unusual, but more importantly, with the wider use of MRI, it is likely that these lesions will be discovered more frequently, and conceivably confused for more dangerous lesions.
Collapse
|
31
|
Abstract
The inhibin/activin family of proteins is known to have a broad distribution of synthesis and expression in many species, as well as a variety of functions in reproductive and other physiological systems. Yet, our knowledge regarding the production and function of inhibin and activin in the central nervous system is relatively limited, especially in humans. The present study aimed to explore the distribution of inhibin/activin protein subunits and receptors in the adult human brain. The human hypothalamus and surrounding basal forebrain was examined using post-mortem tissues from 29 adults. Immunocytochemical studies were conducted with antibodies directed against the inhibin/activin α, βA, and βB subunits, betaglycan and the activin type IIA and IIB receptors. An immunoassay was also utilised to measure dimeric inhibin A and B levels in tissue homogenates of the infundibulum of the hypothalamus. Robust βA subunit immunoreactivity was present in the paraventricular, supraoptic, lateral hypothalamic, infundibular, dorsomedial and suprachiasmatic nuclei of the hypothalamus, in the basal ganglia, and in the nucleus basalis of Meynert. A similar staining distribution was noted for the βB subunit, betaglycan and the type II receptor antibodies, whereas α subunit staining was not detected in any of the major anatomical regions of the human brain. Inhibin B immunoreactivity was present in all tissues, whereas inhibin A levels were below detectable limits. These studies show for the first time that the inhibin/activin protein subunits and receptors can be co-localised in the human brain, implicating potential, diverse neural functions.
Collapse
|
32
|
Circulating endothelial cells, circulating tumour cells, tissue factor, endothelin-1 and overall survival in prostate cancer patients treated with docetaxel. Eur J Cancer 2010; 46:2027-35. [PMID: 20399640 DOI: 10.1016/j.ejca.2010.03.030] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2010] [Revised: 03/22/2010] [Accepted: 03/23/2010] [Indexed: 10/19/2022]
Abstract
PURPOSE We investigated whether serum markers of angiogenesis endothelin-1 (ET-1) and tissue factor (TF), and/or markers of vascular damage such as circulating endothelial cells (CECs), or their relative changes during treatment, were prognostic for overall survival (OS) in castration resistant prostate cancer (CRPC) patients. Additionally, we combined these markers with circulating tumour cells (CTCs) to construct a predictive nomogram for treatment outcome. PATIENTS AND METHODS One hundred and sixty two CRPC patients treated with a docetaxel containing regimen had blood drawn before and at 2-5 weeks and 6-8 weeks after treatment start. Prospectively determined CTC and CEC levels, and retrospectively measured serum concentrations of ET-1 (pg/mL) and TF (pg/mL) were evaluated to determine their prognostic value for OS. RESULTS Baseline CEC, TF and ET-1 were not prognostic for OS. A > or = 3.8-fold increase in CEC 2-5 weeks after treatment initiation was associated with decreased OS (median 10.9 versus 16.8 months; P=0.015), as was any decrease in TF levels compared to baseline levels (median 11.9 versus 21.5 months; P=0.0005). As previously published, baseline and CTC counts > or = 5 at 2-5 weeks were also predictive of decreased OS. Combining CTC with changes in TF and CEC 2-5 weeks after treatment initiation yielded four groups differing in OS (median OS 24.2 versus 16.0 versus 11.4 versus 6.1 months; P<0.0001). CONCLUSION CEC, CTC and TF levels alone and combined can predict early on OS in CRPC patients treated with docetaxel-based therapy. A prospective study to confirm the use of these markers for patient management is needed.
Collapse
|
33
|
Abstract
BACKGROUND High tibial osteotomy is a valuable option for patients with varus gonarthrosis. To avoid difficulties with closing-wedge osteotomies, medial opening-wedge high tibial osteotomies have been advocated. HYPOTHESIS Opening-wedge high tibial osteotomy is a good option in highly active patients with varus gonarthrosis who would like to delay or prevent progression to total knee arthroplasty without activity restrictions. STUDY DESIGN Case series; Level of evidence, 4. METHODS Twenty consecutive patients with varus gonarthrosis were treated with a medial opening-wedge high tibial osteotomy using the Puddu plate and allograft bone graft for a prospective study (14 men and 6 women; average age, 49.4 years [range, 36-67 years]). Gait analysis was performed preoperatively and at 6 months postoperatively. Preoperative radiographs, subjective ratings, and knee scores (Lysholm and Hospital for Special Surgery [HSS] scores) were obtained. At 2 years postoperatively and at the latest follow-up visit (average, 8.3 years), the subjective ratings and knee scores were repeated. RESULTS Gait analysis revealed an abnormal weightbearing pattern preoperatively with the vertical ground-reaction force. The postoperative vertical ground-reaction force revealed a normal double peak pattern. The preoperative adduction moment was 29% greater than the 6-month postoperative adduction moment. The preoperative varus averaged 3.6° and was corrected to an average of 7.5° of valgus postoperatively. All patients subjectively rated their preoperative knee as poor. At 2 years postoperatively, most patients (14) rated their knee as good, with 5 excellent and only 1 fair rating. The average preoperative Lysholm and HSS knee scores were 54.2 and 75.9, respectively, compared with the 2-year postoperative averages of 89.1 and 92.7, respectively. At 8 years postoperatively, there was 70% survivorship with 42% of patients rating their knees as good or excellent. Five patients (25%) had undergone total knee arthroplasty. Lysholm and HSS knee scores were 83.0 and 86.8, respectively, for the surviving knees at 8 years postoperatively. CONCLUSION Medial opening-wedge high tibial osteotomy produces good results in the midterm. After the osteotomy, a more normal appearing weightbearing pattern with double peaks was seen. The adduction moment significantly decreased, resulting in less contact pressure through the medial degenerative compartment of the knee. The authors recommend medial opening-wedge high tibial osteotomy for young patients with varus alignment and medial compartment arthritis to allow this patient population to remain highly active and delay progression to total knee arthroplasty without activity restrictions.
Collapse
|
34
|
Circulating tumour cells early predict progression-free and overall survival in advanced colorectal cancer patients treated with chemotherapy and targeted agents. Ann Oncol 2009; 21:1006-12. [PMID: 19861577 DOI: 10.1093/annonc/mdp463] [Citation(s) in RCA: 152] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Early predictive markers for response are needed for advanced colorectal cancer (ACC) patients. We assessed the value of circulating tumour cells (CTC) in ACC patients treated with chemotherapy plus targeted agents (CAIRO2 phase III trial) and compared the results with computed tomography (CT) imaging. MATERIALS AND METHODS CTC were determined at baseline and at different time points during treatment. Patients were stratified into low (less than three CTC per 7.5 ml of blood) or high CTC (three or more CTC per 7.5 ml of blood). RESULTS A total of 467 patients were assessable for CTC analysis. Among them, 129 patients (29%) with high baseline CTC had a significantly decreased progression-free survival [PFS; hazard ratio (HR) 1.5] and overall survival (OS; HR 2.2) compared with 322 patients with low baseline CTC. This difference remained statistically significant during treatment. The sensitivity and specificity of high CTC at baseline for the prediction of progressive disease on CT imaging were 16.7% and 70.1%, respectively, and of high CTC at 1-2 weeks after the start of treatment 20.0% and 95.1%, respectively. The combined analysis of CTC and CT imaging provided a more accurate outcome assessment than either modality alone. CONCLUSIONS The CTC count before and during treatment independently predicts PFS and OS in ACC patients treated with chemotherapy plus targeted agents and provides additional information to CT imaging.
Collapse
|
35
|
Prognostic significance of circulating tumor cells in patients with metastatic colorectal cancer. Ann Oncol 2009; 20:1223-9. [PMID: 19282466 DOI: 10.1093/annonc/mdn786] [Citation(s) in RCA: 378] [Impact Index Per Article: 25.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND We demonstrated that circulating tumor cell (CTC) number at baseline and follow-up is an independent prognostic factor in metastatic colorectal cancer (mCRC). This analysis was undertaken to explore whether patient and treatment characteristics impact the prognostic value of CTCs. PATIENTS AND METHODS CTCs were enumerated with immunomagnetic separation from the blood of 430 patients with mCRC at baseline and on therapy. Patients were stratified into unfavorable and favorable prognostic groups based on CTC levels of > or = 3 or <3 CTCs/7.5 ml, respectively. Subgroups were analyzed by line of treatment, liver involvement, receipt of oxaliplatin, irinotecan, or bevacizumab, age, and Eastern Cooperative Oncology Group performance status (ECOG PS). RESULTS Seventy-one percent of deaths have occurred. Median follow-up for living patients is 25.8 months. For all patients, progression-free survival (PFS) and overall survival (OS) for unfavorable compared with favorable baseline CTCs is shorter (4.4 versus 7.8 m, P = 0.004 for PFS; 9.4 versus 20.6 m, P < 0.0001 for OS). In all patient subgroups, unfavorable baseline CTC was associated with inferior OS (P < 0.001). In patients receiving first- or second-line therapy (P = 0.003), irinotecan (P = 0.0001), having liver involvement (P = 0.002), >/=65 years (P = 0.0007), and ECOG PS of zero (P = 0.04), unfavorable baseline CTC was associated with inferior PFS. CONCLUSION Baseline CTC count is an important prognostic factor within specific subgroups defined by treatment or patient characteristics.
Collapse
|
36
|
An instrument for combining x-ray multiple diffraction and x-ray topographic imaging for examining crystal microcrystallography and perfection. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2009; 80:033705. [PMID: 19334925 DOI: 10.1063/1.3103571] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Diffraction imaging using x-ray topography (XRT) and x-ray multiple diffraction (XRMD) provide valuable tools for examining the growth defects in crystals and the distributions from ideal lattice symmetry (microcrystallography). The topographic x-ray multiple diffraction microprobe (TMDM) combines the complementary aspects of both techniques enabling XRT and XRMD studies within the same instrument providing a useful resource for the structural characterization of materials that are not very stable in vacuum and electron beam environments. The design of the TMDM instrument is described together with data taken on GaAs (001) and potassium dihydrogen phosphate (001).
Collapse
|
37
|
Probes for measuring fluctuation-induced Maxwell and Reynolds stresses in the edge of the Madison Symmetric Torus reversed field pinch. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2008; 79:10F127. [PMID: 19044611 DOI: 10.1063/1.2955930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Several probes have been constructed to measure fluctuation-induced Maxwell and Reynolds stresses in the edge of the Madison Symmetric Torus reversed field pinch (RFP). The magnetic probe is composed of six magnetic pickup coil triplets. The triplets are separated spatially, which allows for local measurements of the Maxwell stress. To measure the plasma flow components for evaluation of the Reynolds stress, we employ a combination of an optical probe [Kuritsyn et al., Rev. Sci. Indrum. 77, 10F112 (2006)] and a Mach probe. The optical probe measures the radial ion flow locally using Doppler spectroscopy. The Mach probe consists of four current collectors biased negatively with respect to a reference tip and allows for measurements of the poloidal and toroidal components of the bulk plasma flow. The stresses are observed to play an important role in the momentum balance in the RFP edge during internal reconnection events.
Collapse
|
38
|
Plain radiographs are inadequate to identify overlengthening with a radial head prosthesis. J Hand Surg Am 2008; 33:335-9. [PMID: 18343288 DOI: 10.1016/j.jhsa.2007.12.004] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2007] [Revised: 12/03/2007] [Accepted: 12/06/2007] [Indexed: 02/02/2023]
Abstract
PURPOSE A correctly sized radial head implant helps restore more normal elbow motion and load distribution and allows the collateral ligaments to heal in an anatomic position. No single method of measurement has been agreed on. We hypothesized that plain radiographs could be used to evaluate the appropriate length of a radial head prosthesis when we simulated different patterns of ligament disruption. METHODS Osteotomies of the medial and lateral condyles were created in 6 cadaver specimens to simulate 4 conditions: ulnar collateral ligament (UCL) and lateral ulnar collateral ligament (LUCL) intact, UCL intact, LUCL intact, and UCL and LUCL disrupted. Radial heads were resected and replaced with correctly or incorrectly sized monopolar radial head implants. Radiographs were taken after simulated ligament injury with a radial head prosthesis that was either 2 mm too short, the appropriate length, or too long by either 2 or 4 mm. Measurements were recorded between radiographic markers to determine ulnohumeral joint displacement. A 4 x 4 x 2 repeated-measures analysis of variance was performed, as well as post hoc analyses using Tukey's honest significant difference test, to determine statistically significant changes in our radiographic measurements. RESULTS Results showed that disruption of at least 1 ligament alters the ulnohumeral joint separation on the lateral but not on the anteroposterior radiograph. Overlengthening the radial head did not result in a statistically significant change in ulnohumeral space. CONCLUSIONS Replicating radial length is an important but sometimes difficult step during radial head replacement. Standard radiographic assessment of the ulnohumeral joint will not demonstrate marked changes in the ulnohumeral space when the implant is underlengthened by 2 mm or overlengthened by as much as 4 mm, as long as the joint remains located. Disruption of at least 1 collateral ligament alters the ulnohumeral joint separation on the lateral but not on the anteroposterior radiograph.
Collapse
|
39
|
Poster 273: Gait Characteristics, Balance Confidence, and Functional Performance of a Patient With Bilateral Transfemoral Amputation: Comparison Between C-Legs and DAW TK-1PSO Pneumatic Control Knees. Arch Phys Med Rehabil 2007. [DOI: 10.1016/j.apmr.2007.06.688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
40
|
Using intraoperative pelvic landmarks for acetabular component placement in total hip arthroplasty. J Arthroplasty 2006; 21:832-40. [PMID: 16950035 DOI: 10.1016/j.arth.2005.12.001] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2005] [Accepted: 12/02/2005] [Indexed: 02/01/2023] Open
Abstract
Dislocation after total hip arthroplasty is frequently due to acetabular malpositioning. Positioning of the acetabular component using anatomical landmarks may reduce the incidence of dislocation from improper acetabular orientation. The pelvis provides 3 bony landmarks (ilium, superior pubic ramus, and superior acetabulum), which, when used to define a plane, allows cup orientation in abduction and version. Landmarks evaluated in 24 cadaveric acetabuli allowed slightly increased abduction and anteversion of the cup, compared with native acetabuli. Six hundred seventeen primary total hip arthroplasties were performed between 1996 and 2003 using this technique. Mean cup abduction was 44.4 degrees with 13.2 degrees of anteversion. This technique allows satisfactory reproducible cup orientation based on individual pelvic morphology. Review of patient outcome data suggest high patient satisfaction and lower dislocation rate without additional equipment, time, or cost.
Collapse
|
41
|
Stromal-epithelial measurements of prostate cancer in native Japanese and Japanese-American men. Prostate Cancer Prostatic Dis 2005; 7:232-7. [PMID: 15303120 DOI: 10.1038/sj.pcan.4500738] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
We measured the histologic stromal and epithelial tissue components of the benign (normal) and malignant tissue compartments of Japanese-Americans (J-A) and native Japanese (NJ) men living in Japan. The patient cohort included 25 NJ men undergoing radical prostatectomy (RP) in Nagoya, Japan and 25 J-A (second or third generation US born). We conducted tissue image quantitation (in-house image software) of the stromal and epithelial compartments in malignant and adjacent normal tissue areas from a tissue microarray (TMA) selected from radical prostatectomy (RP) blocks. Stromal-epithelial (S-E) areas were determined using immunohistochemical stains for CAM-5.2 epithelial cytokeratin marker and the Masson trichrome stain to measure the stroma component. We observed differences in the volumes of normal and cancer epithelium and stroma within both the J-A and NJ study populations (P<0.01). Only the individual average cancer epithelium (CE) volume (JA=24.1 vs NJ=29.9) differed significantly between the NJ and J-A study populations (P=0.03). Consequently, the S-E ratio in NJ group was significantly different from that of J-A population (P=0.05). The decrease in S-E ratio noted in the malignant tissues of NJ prostate tissue may provide a biological marker for differentiation of the two groups and suggests a need for further investigations into the molecular basis for these histologic differences.
Collapse
|
42
|
Evidence for high-efficiency laser-heated hohlraum performance at 527 nm. PHYSICAL REVIEW LETTERS 2005; 94:055006. [PMID: 15783658 DOI: 10.1103/physrevlett.94.055006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2004] [Indexed: 05/24/2023]
Abstract
A series of experiments conducted on the HELEN laser system [M. J. Norman, Appl. Opt.4120023497], into thermal x-ray generation from hohlraum targets using 527 nm (2omega) wavelength laser light, has shown that it is possible to exceed radiation temperatures previously thought limited by high levels of superthermal or hot electron production or stimulated backscatter. This Letter questions whether the assumptions traditionally applied to hohlraum design with respect to hot plasma filling and the use of 2omega light are too conservative.
Collapse
|
43
|
Positive responses to keeping Florence Nightingale as the symbol of nursing. HOME HEALTHCARE NURSE 2005; 23:60. [PMID: 15632511] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/01/2023]
|
44
|
Abstract
A finite element model of a semiconstrained ankle implant with the tibia and fibula was constructed so that the stresses in the polyethylene liner could be computed. Two different widths of talar components were studied and proximal boundary conditions were computed from an inverse process providing a load of five times body weight appropriately distributed across the osseous structures. von Mises stresses indicated small regions of localized yielding and contact stresses that were similar to those in acetabular cup liners. A wider talar component with 36% more surface area reduced contact stress and von Mises stresses at the center of the polyethylene component by 17%.
Collapse
|
45
|
Efficient multi-keV X-ray sources from Ti-doped aerogel targets. PHYSICAL REVIEW LETTERS 2004; 92:165005. [PMID: 15169241 DOI: 10.1103/physrevlett.92.165005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2003] [Indexed: 05/24/2023]
Abstract
We have measured the production of hnu approximately 4.7 keV x rays from low-density Ti-doped aerogel (rho approximately 3 mg/cc) targets at the OMEGA laser facility (University of Rochester), with the goal of maximizing x-ray output. Forty OMEGA beams (lambda(L)=0.351 microm) illuminated the two cylindrical faces of the target with a total power that ranged from 7 to 14 TW. The laser fully ionizes the target (n(e)/n(crit)</=0.1), and a laser-bleaching wave excites, supersonically, the high-Z emitter ions in the sample. Ti K-shell x-ray emission was spectrally resolved with a two-channel crystal spectrometer and also with a set of filtered aluminum x-ray diodes; both instruments provide absolute measurement of the multi-keV x-ray emission. We find between 40 and 260 J of output with 4.67</=hnu</=5.0 keV.
Collapse
|
46
|
Effects of nortriptyline and paroxetine on postural sway in depressed elderly patients. Am J Geriatr Psychiatry 2002; 10:199-205. [PMID: 11925281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
Abstract
Tricyclic antidepressants (TCAs) have previously been found to be related to an increased incidence of falls in elderly persons. Recent pharmacoepidemiologic and nursing home studies have suggested that the risk of falls and fractures in elderly patients receiving selective serotonin reuptake inhibitors (SSRIs) is not different from that of patients receiving TCAs. The authors therefore evaluated postural sway in an older population of depressed patients randomly assigned to treatment with either nortriptyline or paroxetine and did not find any change in postural sway after 6 weeks' treatment with either antidepressant. Further studies with other SSRIs are needed.
Collapse
|
47
|
Magnetic fields produced by hand held hair dryers, stereo headsets, home sewing machines, and electric clocks. Bioelectromagnetics 2002; 23:14-25. [PMID: 11793402 DOI: 10.1002/bem.94] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
A recent epidemiologic study reported associations between leukemia risk in children and their personal use of television (TV) sets, hair dryers, and stereo headsets, and the prenatal use by their mothers of sewing machines. To provide exposure data to aid in the interpretation of these findings, extremely and very low frequency (ELF and VLF) magnetic fields produced by a sample of each type of appliance were characterized in a field study of volunteers conducted in Washington DC and its Maryland suburbs. Questionnaire data regarding children's or mothers' patterns of usage of each type of appliance were also collected. ELF magnetic fields measured 10 cm from the nozzles of hair dryers were elevated over the ambient by a mean factor of 17 when these devices were in use. Fields near headsets being used to listen to music were not distinguishable from ambient levels except at frequencies below and well above 60 Hz and, even then, field levels were < 0.01 microT. Home sewing machines produced ELF magnetic fields that were elevated by a factor of 2.8 over ambient levels at the front surfaces of the lower abdomens of mothers. Estimated mean daily times of usage of hair dryers, stereo headsets, and sewing machines were 2.6, 19, and 17 minutes, respectively. These data and previously published data on TV sets, do not provide a consistent picture of increased (or decreased) leukemia risk in relation to increasing peak or time weighted average (TWA) ELF magnetic field exposure. The data could, however, conceivably be compatible with some more complex biophysical model with unknown properties. Overall, the results of this study provide little evidence supporting the hypothesis that peak or TWA ELF magnetic fields produced by appliances are causally related to the risk of childhood leukemia in children.
Collapse
|
48
|
Efficient multi-keV underdense laser-produced plasma radiators. PHYSICAL REVIEW LETTERS 2001; 87:275003. [PMID: 11800887 DOI: 10.1103/physrevlett.87.275003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2000] [Indexed: 05/23/2023]
Abstract
Novel, efficient x-ray sources have been created by supersonically heating a large volume of Xe gas. A laser-induced bleaching wave quickly ionizes the high- Z gas, and the resulting plasma emits x rays. This method significantly improves the production of hard x rays because less energy is lost to kinetic energy and sub-keV x rays. The conversion efficiency of laser energy into L-shell radiation between 4-7 keV is measured at approximately 10%, an order of magnitude higher than efficiencies measured from solid disk targets. This higher flux enables material testing and backlighting in new regimes and scales well to future high-powered lasers.
Collapse
|
49
|
Abstract
The Staphylococcus aureus multidrug binding protein QacR represses transcription of the qacA multidrug transporter gene and is induced by structurally diverse cationic lipophilic drugs. Here, we report the crystal structures of six QacR-drug complexes. Compared to the DNA bound structure, drug binding elicits a coil-to-helix transition that causes induction and creates an expansive multidrug-binding pocket, containing four glutamates and multiple aromatic and polar residues. These structures indicate the presence of separate but linked drug-binding sites within a single protein. This multisite drug-binding mechanism is consonant with studies on multidrug resistance transporters.
Collapse
|
50
|
Abstract
Femoral component rotation is important in total knee arthroplasty to optimize patellofemoral and tibiofemoral kinematics. More recently, the epicondylar axis has been cited as the definitive landmark for femoral component rotation. However, there are few studies to support the validity of this rotational landmark and its effect on the patellofemoral and tibiofemoral articulations. In the current study, a total knee arthroplasty was done in 11 knees from cadavers. The knees were tested with various femoral component rotations from 5 degrees internal rotation to 5 degrees external rotation referenced to the epicondylar axis and to the posterior femoral condyles. Each knee acted as its own internal control. The knees were actively ranged from 0 degrees to 100 degrees by a force on the quadriceps tendon in an Oxford knee simulator. Three-dimensional kinematics of all three components were measured whereas a multiaxial transducer imbedded in the patella measured patellofemoral forces. Femoral component rotation parallel to the epicondylar axis resulted in the most normal patellar tracking and minimized patellofemoral shear forces early in flexion. This optimal rotation also minimized tibiofemoral wear motions. These beneficial effects of femoral rotation were less reproducibly related to the posterior condyles. Rotating the femoral component either internal or external to the epicondylar axis worsened knee function by increasing tibiofemoral wear motion and significantly worsening patellar tracking with increased shear forces early in flexion. Based on the current study, the femoral component should be rotationally aligned parallel to the epicondylar axis to avoid patellofemoral and tibiofemoral complications.
Collapse
|