1
|
Impact of heat islands vs. city greening: Real-time monitoring and modeling of drinking water temperature in the city of Montreal in Canada. WATER RESEARCH 2024; 256:121490. [PMID: 38614028 DOI: 10.1016/j.watres.2024.121490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Revised: 02/22/2024] [Accepted: 03/18/2024] [Indexed: 04/15/2024]
Abstract
Urbanization increases the land surface temperature through surface mineralization, adversely affecting vegetation and enhancing the urban heat island (UHI) effect. Global climate change has intensified this warming effect with more frequent and intense heatwaves during hot seasons. While these transformations influence soil temperature, their consequences on drinking water temperature within the drinking water distribution system (DWDS) remains poorly understood. Literature proposes to increase pipe burial depths to mitigate drinking water heating during summer. In this study, we monitored drinking water temperatures in a DWDS in Montreal, Canada with deeply buried pipes (average 1.8 m) during the summer of 2022, focusing on two contrasting zones in terms of UHI and green coverage. Monitoring revealed a 8°C heating effect compared to the water treatment plant, attributed to low green coverage and anthropogenic heat. Conversely, the greener zone exhibited cooler drinking water temperatures, reaching a maximum cooling effect of 8°C as compared to the temperature at the exit of the water treatment plant. Utilizing a soil and water temperature model, we predicted drinking water temperatures within the DWDS with acceptable accuracy. Soil temperature modeling results aligned well with measured water temperatures, highlighting DWDS water temperature approaching its surrounding soil temperature fairly quickly. Despite heatwaves, no immediate correlation emerged between air temperature records and measured water temperatures, emphasizing soil temperature as a superior indicator. An increase in water age displayed no correlation with an increase in measured water temperature, underscoring the dominant influence of UHI and green coverage on water temperature. These findings highlight the cooling advantages of green spaces during summer, providing valuable insights for sustainable urban planning.
Collapse
|
2
|
β-D-glucuronidase activity triggered monitoring of fecal contamination using microbial and chemical source tracking markers at drinking water intakes. WATER RESEARCH 2024; 254:121374. [PMID: 38422696 DOI: 10.1016/j.watres.2024.121374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 02/22/2024] [Accepted: 02/23/2024] [Indexed: 03/02/2024]
Abstract
Intense rainfall and snowmelt events may affect the safety of drinking water, as large quantities of fecal material can be discharged from storm or sewage overflows or washed from the catchment into drinking water sources. This study used β-d-glucuronidase activity (GLUC) with microbial source tracking (MST) markers: human, bovine, porcine mitochondrial DNA markers (mtDNA) and human-associated Bacteroidales HF183 and chemical source tracking (CST) markers including caffeine, carbamazepine, theophylline and acetaminophen, pathogens (Giardia, Cryptosporidium, adenovirus, rotavirus and enterovirus), water quality indicators (Escherichia coli, turbidity) and hydrometeorological data (flowrate, precipitation) to assess the vulnerability of 3 drinking water intakes (DWIs) and identify sources of fecal contamination. Water samples were collected under baseline, snow and rain events conditions in urban and agricultural catchments (Québec, Canada). Dynamics of E. coli, HF183 and WWMPs were similar during contamination events, and concentrations generally varied over 1 order of magnitude during each event. Elevated human-associated marker levels during events demonstrated that urban DWIs were impacted by recent contamination from an upstream municipal water resource recovery facility (WRRF). In the agricultural catchment, mixed fecal pollution was observed with the occurrences and increases of enteric viruses, human bovine and porcine mtDNA during peak contaminating events. Bovine mtDNA qPCR concentrations were indicative of runoff of cattle-derived fecal pollutants to the DWI from diffuse sources following rain events. This study demonstrated that the suitability of a given MST or CST indicator depend on river and catchment characteristics. The sampling strategy using continuous online GLUC activity coupled with MST and CST markers analysis was a more reliable source indicator than turbidity to identify peak events at drinking water intakes.
Collapse
|
3
|
Climate change and future water demand: Implications for chlorine and trihalomethanes management in water distribution systems. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 355:120470. [PMID: 38422852 DOI: 10.1016/j.jenvman.2024.120470] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2023] [Revised: 01/30/2024] [Accepted: 02/20/2024] [Indexed: 03/02/2024]
Abstract
The global change in surface water quality calls for increased preparedness of drinking water utilities. The increasing frequency of extreme climatic events combined with global warming can impact source and treated water characteristics such as temperature and natural organic matter. On the other hand, water saving policies in response to water and energy crisis in some countries can aggravate the situation by increasing the water residence time in the drinking water distribution system (DWDS). This study investigates the individual and combined effect of increased dissolved organic carbon (DOC), increased temperature, and reduced water demand on fate and transport of chlorine and trihalomethanes (THMs) within a full-scale DWDS in Canada. Chlorine and THM prediction models were calibrated with laboratory experiments and implemented in EPANET-MATLAB toolkit for prediction in the DWDS under different combinations of DOC, temperature, and demand. The duration of low chlorine residuals (<0.2 mg/L) and high THM (>80 μg/L) periods within a day in each scenario was reported using a reliability index. Low-reliability zones prone to microbial regrowth or high THM exposure were then delineated geographically on the city DWDS. Results revealed that water demand reduction primarily affects chlorine availability, with less concern for THM formation. The reduction in nodal chlorine reliability was gradual with rising temperature and DOC of the treated water and reducing water demand. Nodal THM reliability remained unchanged until certain thresholds were reached, i.e., temperature >25 °C for waters with DOC <1.52 mg/L, and DOC >2.2 mg/L for waters with temperature = 17 °C. At these critical thresholds, an abrupt network-wide THM exceedance of 80 μg/L occurred. Under higher DOC and temperature levels in future, employing the proposed approach revealed that increasing the applied chlorine dosage (which is a conventional method used to ensure sufficient chlorine coverage) results in elevated exposure toTHMs and is not recommended. This approach aids water utilities in assessing the effectiveness of different intervention measures to solve water quality problems, identify site-specific thresholds leading to major decreases in system reliability, and integrate climate adaptation into water safety management.
Collapse
|
4
|
High-Throughput Short Sequence Typing Schemes for Pseudomonas aeruginosa and Stenotrophomonas maltophilia Pure Culture and Environmental DNA. Microorganisms 2023; 12:48. [PMID: 38257875 PMCID: PMC10819370 DOI: 10.3390/microorganisms12010048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2023] [Revised: 12/22/2023] [Accepted: 12/25/2023] [Indexed: 01/24/2024] Open
Abstract
Molecular typing techniques are utilized to determine genetic similarities between bacterial isolates. However, the use of environmental DNA profiling to assess epidemiologic links between patients and their environment has not been fully explored. This work reports the development and validation of two high-throughput short sequence typing (HiSST) schemes targeting the opportunistic pathogens Pseudomonas aeruginosa and Stenotrophomonas maltophilia, along with a modified SM2I selective medium for the specific isolation of S. maltophilia. These HiSST schemes are based on four discriminative loci for each species and demonstrate high discriminating power, comparable to pairwise whole-genome comparisons. Each scheme includes species-specific PCR primers for precise differentiation from closely related taxa, without the need for upstream culture-dependent methods. For example, the primers targeting the bvgS locus make it possible to distinguish P. aeruginosa from the very closely related Pseudomonas paraeruginosa sp. nov. The selected loci included in the schemes are adapted to massive parallel amplicon sequencing technology. An R-based script implemented in the DADA2 pipeline was assembled to facilitate HiSST analyses for efficient and accurate genotyping of P. aeruginosa and S. maltophilia. We demonstrate the performance of both schemes through in silico validations, assessments against reference culture collections, and a case study involving environmental samples.
Collapse
|
5
|
How clean is your ice machine? Revealing microbial amplification and presence of opportunistic pathogens in hospital ice-water machines. J Hosp Infect 2023; 141:9-16. [PMID: 37604277 DOI: 10.1016/j.jhin.2023.08.007] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Revised: 07/18/2023] [Accepted: 08/05/2023] [Indexed: 08/23/2023]
Abstract
BACKGROUND Ice machines in healthcare facilities have been suspected and even linked to outbreaks and pseudo-outbreaks. Guidelines exist for maintenance of these devices but there is no clear independent infection control standard, and little is known about their microbial contamination. AIM To evaluate the microbial contamination, amplification, and presence of opportunistic pathogens in ice-water machines in a healthcare facility. METHODS Concentrations of general microbial indicators (heterotrophic plate counts (HPC), total and intact cells), faecal indicators (enterococci) and opportunistic pathogens (Pseudomonas aeruginosa, non-tuberculous mycobacteria (NTM), Candida spp.) were measured in 36 ice-water machines on patient wards of a 772-bed hospital. Profile sampling was performed on five ice-water machines and adjacent faucets to identify sites of microbial proliferation. FINDINGS Candida spp. were found in half of ice-water samples while enterococci and P. aeruginosa were present in six and 11 drain inlets respectively. NTM were measured in all ice-water samples and 35 out of 36 biofilms. Pre-filters and ice machines are sites for additional amplification: NTM densities were on average 1.3 log10 higher in water of ice machine flushed 5 min compared to flushed adjacent tap water. CONCLUSION Ice machine design needs to be adapted to reduce microbial proliferation. The absence of correlation between HPC densities (current microbial indicators) and NTM concentrations suggests a need for cleaning efficiency indicators better correlated with opportunistic pathogens. Cleaning and disinfection guidelines of ice machines in healthcare facilities need to be improved, especially when ice is given to the most vulnerable patients, and NTM may be an efficiency indicator.
Collapse
|
6
|
Monitoring of cyanobacterial breakthrough and accumulation by in situ phycocyanin probe system within full-scale treatment plants. ENVIRONMENTAL MONITORING AND ASSESSMENT 2023; 195:1042. [PMID: 37589790 PMCID: PMC10435606 DOI: 10.1007/s10661-023-11657-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Accepted: 07/31/2023] [Indexed: 08/18/2023]
Abstract
Worldwide, there has been an increase in the presence of potentially toxic cyanobacterial blooms in drinking water sources and within drinking water treatment plants (DWTPs). The objective of this study is to validate the use of in situ probes for the detection and management of cyanobacterial breakthrough in high and low-risk DWTPs. In situ phycocyanin YSI EXO2 probes were devised for remote control and data logging to monitor the cyanobacteria in raw, clarified, filtered, and treated water in three full-scale DWTPs. An additional probe was installed inside the sludge holding tank to measure the water quality of the surface of the sludge storage tank in a high-risk DWTP. Simultaneous grab samplings were carried out for taxonomic cell counts and toxin analysis. A total of 23, 9, and 4 field visits were conducted at the three DWTPs. Phycocyanin readings showed a 93-fold fluctuation within 24 h in the raw water of the high cyanobacterial risk plant, with higher phycocyanin levels during the afternoon period. These data provide new information on the limitations of weekly or daily grab sampling. Also, different moving averages for the phycocyanin probe readings can be used to improve the interpretation of phycocyanin signal trends. The in situ probe successfully detected high cyanobacterial biovolumes entering the clarification process in the high-risk plant. Grab sampling results revealed high cyanobacterial biovolumes in the sludge for both high and low-risk plants.
Collapse
|
7
|
Reduction in water consumption in premise plumbing systems: Impacts on lead concentration under different water qualities. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 879:162975. [PMID: 36965725 DOI: 10.1016/j.scitotenv.2023.162975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/21/2023] [Revised: 03/14/2023] [Accepted: 03/17/2023] [Indexed: 05/17/2023]
Abstract
Water conservation measures are increasing in response to regulatory requirements addressing the need for lower environmental footprint and in response to water shortages. In households with lead service lines (LSLs), lowering consumption can adversely impact lead release as it will increase stagnation. Using a lead dissolution model and data from extensive pilot studies on excavated LSLs, the impact of adaptation to different water conservation strategies on dissolved lead contamination at the kitchen tap is assessed under three water qualities and three LSL lengths (3, 14 and 30 m) using hydraulic and water quality modelling. Consumers' behavioural variability is also assessed based on integration of EPANET and results of the stochastic water demand model SIMDEUM. Demand reduction increased the dissolved lead concentrations (Pbdiss) at the end of the LSL with mean values ranging from 28.4 to 63.3 μg/L (without corrosion control) and from 4.6 to 9.9 μg/L with corrosion control (addition of orthophosphate and pH adjustment). Adding orthophosphate (1 mg P/L) to the water reduces the mean Pbdiss values at the kitchen tap from 7.1 μg/L to 1.2 μg/L for a high water demand scenario and from 31.2 to 4.9 μg/L for a low water demand scenario. Finally, the Integrated Exposure Uptake Biokinetic (IEUBK) model is used to predict the potential blood lead levels (BLLs) for children aged 0-84 months. Results showed that the orthophosphate addition of only 1 mg P/L can significantly decrease the proportion of children with a BLL >5 μg/dL, from 82 % to 17 %, under the most extreme water conservation scenario studied, using the 90th percentile of Pbdiss concentrations during usage at kitchen tap. Wide variations of Pbdiss concentrations at the kitchen tap were calculated at times of use over a week (up to 155 μg/L in lower demand scenarios, without corrosion control) showing evident limitations of single random daytime sampling.
Collapse
|
8
|
Serratia marcescens Colonization in a Neonatal Intensive Care Unit Has Multiple Sources, with Sink Drains as a Major Reservoir. Appl Environ Microbiol 2023; 89:e0010523. [PMID: 37067412 PMCID: PMC10231179 DOI: 10.1128/aem.00105-23] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2023] [Accepted: 03/27/2023] [Indexed: 04/18/2023] Open
Abstract
Compelling evidence suggests a contribution of the sink environment to the transmission of opportunistic pathogens from the hospital environment to patients in neonatal intensive care units (NICU). In this study, the distribution of the opportunistic pathogen Serratia marcescens in the sink environment and newborns in a NICU was investigated. More than 500 sink drain and faucet samples were collected over the course of five sampling campaigns undertaken over 3 years. Distribution and diversity of S. marcescens were examined with a modified MacConkey medium and a high-throughput short-sequence typing (HiSST) method. Sink drains were an important reservoir of S. marcescens, with an average of 44% positive samples, whereas no faucet sample was positive. The genotypic diversity of S. marcescens was moderate, with an average of two genotypes per drain, while the spatial distribution of S. marcescens was heterogeneous. The genotypic profiles of 52 clinical isolates were highly heterogeneous, with 27 unique genotypes, of which 71% of isolates were found in more than one patient. S. marcescens acquisition during the first outbreaks was mainly caused by horizontal transmissions. HiSST analyses revealed 10 potential cases of patient-to-patient transmission of S. marcescens, five cases of patient-to-sink transmission, and one bidirectional transfer between sink and patient. Environmental and clinical isolates were found in sink drains up to 1 year after the first detection, supporting persisting drain colonization. This extensive survey suggests multiple reservoirs of S. marcescens within the NICU, including patients and sink drains, but other external sources should also be considered. IMPORTANCE The bacterium Serratia marcescens is an important opportunistic human pathogen that thrives in many environments, can become multidrug resistant, and is often involved in nosocomial outbreaks in neonatal intensive care units (NICU). We evaluated the role of sinks during five suspected S. marcescens outbreaks in a NICU. An innovative approach combining molecular and culture methods was used to maximize the detection and typing of S. marcescens in the sink environment. Our results indicate multiple reservoirs of S. marcescens within the NICU, including patients, sink drains, and external sources. These results highlight the importance of sinks as a major reservoir of S. marcescens and potential sources of future outbreaks.
Collapse
|
9
|
Controlling Legionella pneumophila in Showerheads: Combination of Remedial Intervention and Preventative Flushing. Microorganisms 2023; 11:1361. [PMID: 37374862 DOI: 10.3390/microorganisms11061361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2023] [Revised: 05/17/2023] [Accepted: 05/20/2023] [Indexed: 06/29/2023] Open
Abstract
Shock chlorination and remedial flushing are suggested to address Legionella pneumophila (Lp) contamination in buildings or during their (re)commissioning. However, data on general microbial measurements (adenosine tri-phosphate [ATP], total cell counts [TCC]), and the abundance of Lp are lacking to support their temporary implementation with variable water demands. In this study, the weekly short-term (3-week) impact of shock chlorination (20-25 mg/L free chlorine, 16 h) or remedial flushing (5-min flush) combined with distinct flushing regimes (daily, weekly, stagnant) was investigated in duplicates of showerheads in two shower systems. Results showed that the combination of stagnation and shock chlorination prompted biomass regrowth, with ATP and TCC in the first draws reaching large regrowth factors of 4.31-7.07-fold and 3.51-5.68-fold, respectively, from baseline values. Contrastingly, remedial flushing followed by stagnation generally resulted in complete or larger regrowth in Lp culturability and gene copies (gc). Irrespective of the intervention, daily flushed showerheads resulted in significantly (p < 0.05) lower ATP and TCC, as well as lower Lp concentrations than weekly flushes, in general. Nonetheless, Lp persisted at concentrations ranging from 11 to 223 as the most probable number per liter (MPN/L) and in the same order of magnitude (103-104 gc/L) than baseline values after remedial flushing, despite daily/weekly flushing, unlike shock chlorination which suppressed Lp culturability (down 3-log) for two weeks and gene copies by 1-log. This study provides insights on the most optimal short-term combination of remedial and preventative strategies that can be considered pending the implementation of suitable engineering controls or building-wide treatment.
Collapse
|
10
|
Characterization of the aerosol produced from an aerated jet. WATER RESEARCH 2023; 229:119432. [PMID: 36495852 DOI: 10.1016/j.watres.2022.119432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Revised: 11/15/2022] [Accepted: 11/25/2022] [Indexed: 06/17/2023]
Abstract
Faucet aerators that form aerated water jets generate aerosols, which can constitute a risk of infection if the water is contaminated, particularly for vulnerable individuals near the sink. In this study, we characterize the size and trajectory of water droplets produced from an aerated jet. The detected particle diameter ranged from 3 to 150μm. The concentration of droplets in the air varied from near-zero to a maximum of 2×1011particles/m3, depending on the location relative to the jet. We found four relevant categories of droplets based on their trajectories following their emission at the jet's free surface: particles with inertia high enough to escape the immediate vicinity of the jet (category 1), particles moving towards the jet (category 2), particles drawn into the aerator, which only included particles with a diameter smaller than 50μm (category 3), and particles with a near-vertical trajectory (category 4). Tracing category 1 particles to their generation location on the water interface shows a higher emission rate near the aerator. Finally, we employ a numerical model to compute the subsequent trajectories of droplets detected at the limits of the sampled domain. We find that particles whose diameter is smaller than 55μm completely dry and become airborne. Larger droplets deposit within a radius of 7cm around the jet, assuming a surface is located 20cm below the aerator tip. These results increase the fundamental understanding of the emission mechanisms of droplets in aerated jets and their fate in the sink environment.
Collapse
|
11
|
1193. Disinfection of the Sink Drains to Reduce a Source of Serratia marcescens During Infection Outbreaks in a Neonatal Intensive Care Unit. Open Forum Infect Dis 2022. [DOI: 10.1093/ofid/ofac492.1028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Abstract
Background
Sink drains are known reservoirs of pathogens and have been associated with multiple nosocomial outbreaks. In this study, the distribution of Serratia marcescens was investigated within the sink environment of a NICU and in colonized or infected newborns. The effect of different types of drain disinfection on bacterial concentration and on the detection of Serratia marcescens in sink drains was also investigated.
Methods
Sink drains from a NICU were sampled: 20 drains sampled for 6 weeks in the first year and 28 drains sampled for 5 months in the second year. S. marcescens isolated from positive patients were collected. A high-throughput short sequence typing (HiSST) method was developed to identify S. marcescens and compare strains and environmental DNA from sink drains with 56 clinical strains from 5 nosocomial outbreaks. Five interventions were tested: self-disinfecting drains, hot water disinfection, chlorine disinfection, steam disinfection and hot tap water flushing. Bacterial concentration of samples was measured in culture and flow cytometry and the HiSST method was used to identify S. marcescens.
Results
During the first and second sampling campaigns, 40% and 60% of sink drain samples were positive for S. marcescens with a moderate genotype diversity (1 to 11 different STs). The genotype profile of the 56 clinical strains was heterogeneous (26 STs). Four distinct STs were retrieved in 8 sinks after detection in patients whereas 1 ST was detected in a sink before detection in patient. Some environmental and clinical strains were found in drains for up to a year after the first sampling campaign. Each tested drain intervention reduced culturable bacteria (4-8 log) and viable bacteria (2-3 log), except for chlorine. The self-disinfecting drains, hot water and steam disinfection were able to remove temporarily S. marcescens from the drains.
Conclusion
The high genotypic diversity of the clinical strains suggests diffuse sources of S. marcescens within the NICU likely to cause nosocomial infection outbreaks. The self-disinfecting drains, hot water and steam disinfection seem to be the best methods to reduce bacterial concentration in drains and eliminate S. marcescens in the short term, thus limiting the risk of pathogens spread from the sink environment to patients.
Disclosures
All Authors: No reported disclosures.
Collapse
|
12
|
Shotgun Metagenomic Sequencing to Assess Cyanobacterial Community Composition following Coagulation of Cyanobacterial Blooms. Toxins (Basel) 2022; 14:688. [PMID: 36287957 PMCID: PMC9607033 DOI: 10.3390/toxins14100688] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 09/29/2022] [Accepted: 10/01/2022] [Indexed: 06/16/2023] Open
Abstract
The excessive proliferation of cyanobacteria in surface waters is a widespread problem worldwide, leading to the contamination of drinking water sources. Short- and long-term solutions for managing cyanobacterial blooms are needed for drinking water supplies. The goal of this research was to investigate the cyanobacteria community composition using shotgun metagenomics in a short term, in situ mesocosm experiment of two lakes following their coagulation with ferric sulfate (Fe2(SO4)3) as an option for source water treatment. Among the nutrient paramenters, dissolved nitrogen was related to Microcystis in both Missisquoi Bay and Petit Lac St. François, while the presence of Synechococcus was related to total nitrogen, dissolved nitrogen, dissolved organic carbon, and dissolved phosphorus. Results from the shotgun metagenomic sequencing showed that Dolichospermum and Microcystis were the dominant genera in all of the mesocosms in the beginning of the sampling period in Missisquoi Bay and Petit Lac St. François, respectively. Potentially toxigenic genera such as Microcystis were correlated with intracellular microcystin concentrations. A principal component analysis showed that there was a change of the cyanobacterial composition at the genus level in the mesocosms after two days, which varied across the studied sites and sampling time. The cyanobacterial community richness and diversity did not change significantly after its coagulation by Fe2(SO4)3 in all of the mesocosms at either site. The use of Fe2(SO4)3 for an onsite source water treatment should consider its impact on cyanobacterial community structure and the reduction of toxin concentrations.
Collapse
|
13
|
Evidence-Based Framework to Manage Cyanobacteria and Cyanotoxins in Water and Sludge from Drinking Water Treatment Plants. Toxins (Basel) 2022; 14:toxins14060410. [PMID: 35737071 PMCID: PMC9228313 DOI: 10.3390/toxins14060410] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 06/12/2022] [Accepted: 06/13/2022] [Indexed: 02/07/2023] Open
Abstract
Freshwater bodies and, consequently, drinking water treatment plants (DWTPs) sources are increasingly facing toxic cyanobacterial blooms. Even though conventional treatment processes including coagulation, flocculation, sedimentation, and filtration can control cyanobacteria and cell-bound cyanotoxins, these processes may encounter challenges such as inefficient removal of dissolved metabolites and cyanobacterial cell breakthrough. Furthermore, conventional treatment processes may lead to the accumulation of cyanobacteria cells and cyanotoxins in sludge. Pre-oxidation can enhance coagulation efficiency as it provides the first barrier against cyanobacteria and cyanotoxins and it decreases cell accumulation in DWTP sludge. This critical review aims to: (i) evaluate the state of the science of cyanobacteria and cyanotoxin management throughout DWTPs, as well as their associated sludge, and (ii) develop a decision framework to manage cyanobacteria and cyanotoxins in DWTPs and sludge. The review identified that lab-cultured-based pre-oxidation studies may not represent the real bloom pre-oxidation efficacy. Moreover, the application of a common exposure unit CT (residual concentration × contact time) provides a proper understanding of cyanobacteria pre-oxidation efficiency. Recently, reported challenges on cyanobacterial survival and growth in sludge alongside the cell lysis and cyanotoxin release raised health and technical concerns with regards to sludge storage and sludge supernatant recycling to the head of DWTPs. According to the review, oxidation has not been identified as a feasible option to handle cyanobacterial-laden sludge due to low cell and cyanotoxin removal efficacy. Based on the reviewed literature, a decision framework is proposed to manage cyanobacteria and cyanotoxins and their associated sludge in DWTPs.
Collapse
|
14
|
Locating illicit discharges in storm sewers in urban areas using multi-parameter source tracking: Field validation of a toolbox composite index to prioritize high risk areas. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 811:152060. [PMID: 34861306 DOI: 10.1016/j.scitotenv.2021.152060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 11/24/2021] [Accepted: 11/25/2021] [Indexed: 06/13/2023]
Abstract
In urban areas served by separate sewerage systems, illicit connections to the storm drain system from residences or commercial establishments are frequent whether these misconnections were made accidentally or deliberately. As a result, untreated and contaminated wastewater enters into storm sewers leading to pollution of receiving waters and non-compliance with water quality standards. Typical procedures for detecting illicit connections to the storm sewer system are time consuming and expensive, especially in a highly urbanised area. In this study, we investigated the use of human wastewater micropollutants WWMPs (caffeine, theophylline, and carbamazepine) and advanced DNA molecular markers (human specific Bacteroides HF183 and mitochondrial DNA) as anthropogenic tracers in order to assist identifying potential cross connections. Water samples from storm outfalls and storm sewer pipes in three urban subcatchments were collected in dry weather from 2013 to 2018. All samples contained various concentrations of these markers especially HF183, caffeine and theophylline, suggesting that the storm pipe system studied is widely contaminated by sanitary sewers. None of the traditional indicators or markers tested is sufficient alone to determine the origin of fecal pollution. In a highly urbanised area, the combination of at least three specific human markers was needed in order to locate the residential section with likely misconnections. The human specific Bacteroides HF183, and theophylline appeared to be the most effective markers (along with E. coli) of crossconnections, whereas carbamazepine can provide an indication of contamination through sanitary sewer exfiltration. A composite sewer cross-connection index was developed, and eight misconnected houses were identified and corrected. The index approach enables the reduction of false positives that could lead to expensive interventions to identify cross-connected households. The results show the multiparameter source tracking toolbox as an effective method to identify sewer cross connections for sustainable storm water management.
Collapse
|
15
|
Compromised Effectiveness of Thermal Inactivation of Legionella pneumophila in Water Heater Sediments and Water, and Influence of the Presence of Vermamoeba vermiformis. Microorganisms 2022; 10:microorganisms10020443. [PMID: 35208896 PMCID: PMC8874534 DOI: 10.3390/microorganisms10020443] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 02/04/2022] [Accepted: 02/09/2022] [Indexed: 11/21/2022] Open
Abstract
Intermittent reduction of temperature set-points and periodic shutdowns of water heaters have been proposed to reduce energy consumption in buildings. However, the consequences of such measures on the occurrence and proliferation of Legionella pneumophila (Lp) in hot water systems have not been documented. The impact of single and repeated heat shocks was investigated using an environmental strain of L. pneumophila and a reference strain of V. vermiformis. Heat shocks at temperatures ranging from 50 °C to 70 °C were applied for 1 h and 4 h in water and water heaters loose deposits (sludge). The regrowth potential of heat-treated culturable L. pneumophila in presence of V. vermiformis in water heaters sludges was evaluated. A 2.5-log loss of culturability of L. pneumophila was observed in simulated drinking water at 60 °C while a 4-log reduction was reached in water heaters loose deposits. Persistence of Lp after 4 h at 55 °C was shown and the presence of V. vermiformis in water heater’s loose deposits resulted in a drastic amplification (5-log). Results show that thermal inactivation by heat shock is only efficient at elevated temperatures (50 °C) in both water and loose deposits. The few remaining organisms can rapidly proliferate during storage at lower temperature in the presence of hosts.
Collapse
|
16
|
Assessment of automated off-line solid-phase extraction LC-MS/MS to monitor EPA priority endocrine disruptors in tap water, surface water, and wastewater. Talanta 2022; 241:123216. [PMID: 35042051 DOI: 10.1016/j.talanta.2022.123216] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 01/04/2022] [Accepted: 01/05/2022] [Indexed: 10/19/2022]
Abstract
EPA method 539.1 recently introduced an expanded list of priority endocrine-disrupting compounds (EDCs), some of which were also included in the Unregulated Contaminant Monitoring Rule 3 (UCMR3). Though standardized methods are available for drinking water, analysis of steroid hormones and bisphenol A (BPA) at the ultra-trace level remains challenging. This study set out to evaluate the suitability of automated off-line solid-phase extraction (SPE) liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) for the determination of EPA-priority EDCs in environmental water matrixes (tap water, surface water, and wastewater influents and effluents). The target molecules included 14 steroid hormones (altrenogest, androstenedione, equilenin, equilin, α-estradiol, β-estradiol, estriol, estrone, ethinylestradiol, levonorgestrel, medroxyprogesterone, norethindrone, progesterone, testosterone) and BPA. Factors that may influence the analytical performance were assessed. This involved, for instance, testing combinations of SPE materials from different brands and protocol variations. Several materials presented absolute extraction efficiencies in acceptable ranges. Initial sample pH, nature of reconstitution medium, and mobile phase salt concentration were among the potential factors affecting analyte signal. Storage conditions (different preservative agents) possibly exerted the strongest influence, in agreement with the literature. Limits of detection were in the range of 0.03-0.5 ng/L in drinking water, 0.1-0.5 ng/L in surface water, and 0.16-1 ng/L in wastewater. Method validation also involved testing linearity, accuracy, and precision in reagent water and matrix-matched extracted calibrants. The method was applied to field-collected water samples in Eastern Canada. Summed EDC concentrations remained low in tap water (<LOQ-0.92 ng/L), while higher detection frequencies and contamination levels were reported in riverine surface waters (2.6-37 ng/L) and municipal wastewaters (10-424 ng/L).
Collapse
|
17
|
Metagenomic study to evaluate functional capacity of a cyanobacterial bloom during oxidation. CHEMICAL ENGINEERING JOURNAL ADVANCES 2021. [DOI: 10.1016/j.ceja.2021.100151] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
18
|
Changes in Escherichia coli to enteric protozoa ratios in rivers: Implications for risk-based assessment of drinking water treatment requirements. WATER RESEARCH 2021; 205:117707. [PMID: 34619609 DOI: 10.1016/j.watres.2021.117707] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Revised: 09/11/2021] [Accepted: 09/22/2021] [Indexed: 06/13/2023]
Abstract
Minimum treatment requirements are set in response to established or anticipated levels of enteric pathogens in the source water of drinking water treatment plants (DWTPs). For surface water, contamination can be determined directly by monitoring reference pathogens or indirectly by measuring fecal indicators such as Escherichia coli (E. coli). In the latter case, a quantitative interpretation of E. coli for estimating reference pathogen concentrations could be used to define treatment requirements. This study presents the statistical analysis of paired E. coli and reference protozoa (Cryptosporidium, Giardia) data collected monthly for two years in source water from 27 DWTPs supplied by rivers in Canada. E. coli/Cryptosporidium and E. coli/Giardia ratios in source water were modeled as the ratio of two correlated lognormal variables. To evaluate the potential of E. coli for defining protozoa treatment requirements, risk-based critical mean protozoa concentrations in source water were determined with a reverse quantitative microbial risk assessment (QMRA) model. Model assumptions were selected to be consistent with the World Health Organization (WHO) Guidelines for drinking-water quality. The sensitivity of mean E. coli concentration trigger levels to identify these critical concentrations in source water was then evaluated. Results showed no proportionalities between the log of mean E. coli concentrations and the log of mean protozoa concentrations. E. coli/protozoa ratios at DWTPs supplied by small rivers in agricultural and forested areas were typically 1.0 to 2.0-log lower than at DWTPs supplied by large rivers in urban areas. The seasonal variations analysis revealed that these differences were related to low mean E. coli concentrations during winter in small rivers. To achieve the WHO target of 10-6 disability-adjusted life year (DALY) per person per year, a minimum reduction of 4.0-log of Cryptosporidium would be required for 20 DWTPs, and a minimum reduction of 4.0-log of Giardia would be needed for all DWTPs. A mean E. coli trigger level of 50 CFU 100 mL-1 would be a sensitive threshold to identify critical mean concentrations for Cryptosporidium but not for Giardia. Treatment requirements higher than 3.0-log would be needed at DWTPs with mean E. coli concentrations as low as 30 CFU 100 mL-1 for Cryptosporidium and 3 CFU 100 mL-1 for Giardia. Therefore, an E. coli trigger level would have limited value for defining health-based treatment requirements for protozoa at DWTPs supplied by small rivers in rural areas.
Collapse
|
19
|
Importance of Distributional Forms for the Assessment of Protozoan Pathogens Concentrations in Drinking-Water Sources. RISK ANALYSIS : AN OFFICIAL PUBLICATION OF THE SOCIETY FOR RISK ANALYSIS 2021; 41:1396-1412. [PMID: 33103818 DOI: 10.1111/risa.13613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 09/18/2020] [Accepted: 10/02/2020] [Indexed: 06/11/2023]
Abstract
The identification of appropriately conservative statistical distributions is needed to predict microbial peak events in drinking water sources explicitly. In this study, Poisson and mixed Poisson distributions with different upper tail behaviors were used for modeling source water Cryptosporidium and Giardia data from 30 drinking water treatment plants. Small differences (<0.5-log) were found between the "best" estimates of the mean Cryptosporidium and Giardia concentrations with the Poisson-gamma and Poisson-log-normal models. However, the upper bound of the 95% credibility interval on the mean Cryptosporidium concentrations of the Poisson-log-normal model was considerably higher (>0.5-log) than that of the Poisson-gamma model at four sites. The improper choice of a model may, therefore, mislead the assessment of treatment requirements and health risks associated with the water supply. Discrimination between models using the marginal deviance information criterion (mDIC) was unachievable because differences in upper tail behaviors were not well characterized with available data sets ( n<30 ). Therefore, the gamma and the log-normal distributions fit the data equally well but may predict different risk estimates when they are used as an input distribution in an exposure assessment. The collection of event-based monitoring data and the modeling of larger routine monitoring data sets are recommended to identify appropriately conservative distributions to predict microbial peak events.
Collapse
|
20
|
Impact of Hydrometeorological Events for the Selection of Parametric Models for Protozoan Pathogens in Drinking-Water Sources. RISK ANALYSIS : AN OFFICIAL PUBLICATION OF THE SOCIETY FOR RISK ANALYSIS 2021; 41:1413-1426. [PMID: 33103797 DOI: 10.1111/risa.13612] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 07/07/2020] [Accepted: 07/10/2020] [Indexed: 06/11/2023]
Abstract
Temporal variations in concentrations of pathogenic microorganisms in surface waters are well known to be influenced by hydrometeorological events. Reasonable methods for accounting for microbial peaks in the quantification of drinking water treatment requirements need to be addressed. Here, we applied a novel method for data collection and model validation to explicitly account for weather events (rainfall, snowmelt) when concentrations of pathogens are estimated in source water. Online in situ β-d-glucuronidase activity measurements were used to trigger sequential grab sampling of source water to quantify Cryptosporidium and Giardia concentrations during rainfall and snowmelt events at an urban and an agricultural drinking water treatment plant in Quebec, Canada. We then evaluate if mixed Poisson distributions fitted to monthly sampling data ( n = 30 samples) could accurately predict daily mean concentrations during these events. We found that using the gamma distribution underestimated high Cryptosporidium and Giardia concentrations measured with routine or event-based monitoring. However, the log-normal distribution accurately predicted these high concentrations. The selection of a log-normal distribution in preference to a gamma distribution increased the annual mean concentration by less than 0.1-log but increased the upper bound of the 95% credibility interval on the annual mean by about 0.5-log. Therefore, considering parametric uncertainty in an exposure assessment is essential to account for microbial peaks in risk assessment.
Collapse
|
21
|
Using surrogate data to assess risks associated with microbial peak events in source water at drinking water treatment plants. WATER RESEARCH 2021; 200:117296. [PMID: 34098267 DOI: 10.1016/j.watres.2021.117296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 05/20/2021] [Accepted: 05/23/2021] [Indexed: 06/12/2023]
Abstract
A monitoring strategy was implemented at two drinking water treatment plants in Quebec, Canada, to evaluate microbial reduction performances of full-scale treatment processes under different source water conditions. β-D-glucuronidase activity in source water was automatically monitored in near-real-time to establish baseline and event conditions at each location. High-volume water samples (50-1,500 L) were collected at the inflow and the outflow of coagulation/flocculation, filtration, and UV disinfection processes and were analysed for two naturally occurring surrogate organisms: Escherichia coli and Clostridium perfringens. Source water Cryptosporidium data and full-scale C. perfringens reduction data were entered into a quantitative microbial risk assessment (QMRA) model to estimate daily infection risks associated with exposures to Cryptosporidium via consumption of treated drinking water. Daily mean E. coli and Cryptosporidium concentrations in source water under event conditions were in the top 5% (agricultural site) or in the top 15% (urban site) of what occurs through the year at these drinking water treatment plants. Reduction performances of up to 6.0-log for E. coli and 5.6-log for C. perfringens were measured by concentrating high-volume water samples throughout the treatment train. For both drinking water treatment plants, removal performances by coagulation/flocculation/sedimentation processes were at the high end of the range of those reported in the literature for bacteria and bacterial spores. Reductions of E. coli and C. perfringens by floc blanket clarification, ballasted clarification and rapid sand filtration did not deteriorate during two snowmelt/rainfall events. QMRA results suggested that daily infection risks were similar during two rainfall/snowmelt events than during baseline conditions. Additional studies investigating full-scale reductions would be desirable to improve the evaluation of differences in treatment performances under various source water conditions.
Collapse
|
22
|
Faucet aerator design influences aerosol size distribution and microbial contamination level. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 775:145690. [PMID: 33631571 DOI: 10.1016/j.scitotenv.2021.145690] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 02/03/2021] [Accepted: 02/03/2021] [Indexed: 06/12/2023]
Abstract
Faucet aerators have been linked to multiple opportunistic pathogen outbreaks in hospital, especially Pseudomonas aeruginosa, their complex structure promoting biofilm development. The importance of bacteria aerosolization by faucet aerators and their incidence on the risk of infection remain to be established. In this study, ten different types of aerators varying in complexity, flow rates and type of flow were evaluated in a controlled experimental setup to determine the production of aerosols and the level of contamination. The aerosol particle number density and size distribution were assessed using a particle spectrometer. The bacterial load was quantified with a 14-stage cascade impactor, where aerosol particles were captured and separated by size, then analysed by culture and flow cytometry. The water was seeded with Pseudomonas fluorescens as a bacterial indicator. Aerosol particle size and mean mass distribution varied depending on the aerator model. Devices without aeration or with laminar flow produced the lowest number and mass of aerosol particles when measured with spectrometry. Models with aeration displayed wide differences in their potential production of aerosol particles. A new aerator with a low flow, no air inlet in its structure, and a spray stream produced 12 to 395 times fewer aerosol particles containing bacteria. However, the impact of low flow on biofilm development and incorporation of pathogens should be further investigated. Repeated use of aerators resulted in fouling which increased the quantity of bacteria released through aerosol particles. An in-depth mechanical cleaning including complete dismantling of the aerator was required to recover initial performances. Aerators should be selected to minimize aerosol production, considering the ease of maintenance and the main water usage at each sink. Low flow aerators produced a lower number of contaminated aerosol particles when new but may be more susceptible to fouling and quickly lose their initial advantage.
Collapse
|
23
|
Demonstrating the reduction of enteric viruses by drinking water treatment during snowmelt episodes in urban areas. WATER RESEARCH X 2021; 11:100091. [PMID: 33598650 PMCID: PMC7868990 DOI: 10.1016/j.wroa.2021.100091] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 12/21/2020] [Accepted: 01/20/2021] [Indexed: 05/25/2023]
Abstract
This study investigates short-term fluctuations in virus concentrations in source water and their removal by full-scale drinking water treatment processes under different source water conditions. Transient peaks in raw water faecal contamination were identified using in situ online β-d-glucuronidase activity monitoring at two urban drinking water treatment plants. During these peaks, sequential grab samples were collected at the source and throughout the treatment train to evaluate concentrations of rotavirus, adenovirus, norovirus, enterovirus, JC virus, reovirus, astrovirus and sapovirus by reverse transcription and real-time quantitative PCR. Virus infectivity was assessed through viral culture by measurement of cytopathic effect and integrated cell culture qPCR. Virus concentrations increased by approximately 0.5-log during two snowmelt/rainfall episodes and approximately 1.0-log following a planned wastewater discharge upstream of the drinking water intake and during a β-d-glucuronidase activity peak in dry weather conditions. Increases in the removal of adenovirus and rotavirus by coagulation/flocculation processes were observed during peak virus concentrations in source water, suggesting that these processes do not operate under steady-state conditions but dynamic conditions in response to source water conditions. Rotavirus and enterovirus detected in raw and treated water samples were predominantly negative in viral culture. At one site, infectious adenoviruses were detected in raw water and water treated by a combination of ballasted clarification, ozonation, GAC filtration, and UV disinfection operated at a dose of 40 mJ cm-2. The proposed sampling strategy can inform the understanding of the dynamics associated with virus concentrations at drinking water treatment plants susceptible to de facto wastewater reuse.
Collapse
|
24
|
Local Adaptation of Legionella pneumophila within a Hospital Hot Water System Increases Tolerance to Copper. Appl Environ Microbiol 2021; 87:e00242-21. [PMID: 33674435 PMCID: PMC8117758 DOI: 10.1128/aem.00242-21] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 02/25/2021] [Indexed: 11/20/2022] Open
Abstract
In large-building water systems, Legionella pneumophila is exposed to common environmental stressors such as copper. The aim of this study was to evaluate the susceptibility to copper of L. pneumophila isolates recovered from various sites: two clinical and seven environmental isolates from hot water system biofilm and water and from cooling tower water. After a 1-week acclimation in simulated drinking water, strains were exposed to various copper concentrations (0.8 to 5 mg/liter) for over 672 h. Complete loss of culturability was observed for three isolates following copper exposure to 5 mg/liter for 672 h. Two sequence type 1427 (ST1427)-like isolates were highly sensitive to copper, while the other two, isolated from biofilm samples, maintained higher culturability. The expression of the copper resistance gene copA evaluated by reverse transcription-quantitative PCR (RT-qPCR) was significantly higher for the biofilm isolates. All four ST1427-like isolates were recovered from the same water system during an outbreak. Whole-genome sequencing results confirmed that the four isolates are very close phylogenetically, differing by only 29 single nucleotide polymorphisms, suggesting in situ adaptation to microenvironmental conditions, possibly due to epigenetic regulation. These results indicate that the immediate environment within a building water distribution system influences the tolerance of L. pneumophila to copper. Increased contact of L. pneumophila biofilm strains with copper piping or copper alloys in the heat exchanger might lead to local adaptation. The phenotypic differences observed between water and biofilm isolates from the hot water system of a health care facility warrants further investigation to assess the relevance of evaluating disinfection performances based on water sampling alone.IMPORTANCELegionella pneumophila is a pathogen indigenous to natural and large building water systems in the bulk and the biofilm phases. The immediate environment within a system can impact the tolerance of L. pneumophila to environmental stressors, including copper. In health care facilities, copper levels in water can vary, depending on water quality, plumbing materials, and age. This study evaluated the impact of the isolation site (water versus biofilm, hot water system versus cooling tower) within building water systems. Closely related strains isolated from a health care facility hot water system exhibited variable tolerance to copper stress, shown by differential expression of copA, with biofilm isolates displaying highest expression and tolerance. Relying on the detection of L. pneumophila in water samples following exposure to environmental stressors such as copper may underestimate the prevalence of L. pneumophila, leading to inappropriate risk management strategies and increasing the risk of exposure for vulnerable patients.
Collapse
|
25
|
Can Cyanobacterial Diversity in the Source Predict the Diversity in Sludge and the Risk of Toxin Release in a Drinking Water Treatment Plant? Toxins (Basel) 2021; 13:toxins13010025. [PMID: 33401450 PMCID: PMC7823770 DOI: 10.3390/toxins13010025] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 12/22/2020] [Accepted: 12/29/2020] [Indexed: 02/05/2023] Open
Abstract
Conventional processes (coagulation, flocculation, sedimentation, and filtration) are widely used in drinking water treatment plants and are considered a good treatment strategy to eliminate cyanobacterial cells and cell-bound cyanotoxins. The diversity of cyanobacteria was investigated using taxonomic cell counts and shotgun metagenomics over two seasons in a drinking water treatment plant before, during, and after the bloom. Changes in the community structure over time at the phylum, genus, and species levels were monitored in samples retrieved from raw water (RW), sludge in the holding tank (ST), and sludge supernatant (SST). Aphanothece clathrata brevis, Microcystis aeruginosa, Dolichospermum spiroides
, and Chroococcus minimus were predominant species detected in RW by taxonomic cell counts. Shotgun metagenomics revealed that Proteobacteria was the predominant phylum in RW before and after the cyanobacterial bloom. Taxonomic cell counts and shotgun metagenomic showed that the Dolichospermum bloom occurred inside the plant. Cyanobacteria and Bacteroidetes were the major bacterial phyla during the bloom. Shotgun metagenomics also showed that Synechococcus, Microcystis
, and Dolichospermum were the predominant detected cyanobacterial genera in the samples. Conventional treatment removed more than 92% of cyanobacterial cells but led to cell accumulation in the sludge up to 31 times more than in the RW influx. Coagulation/sedimentation selectively removed more than 96% of Microcystis and Dolichospermum. Cyanobacterial community in the sludge varied from raw water to sludge during sludge storage (1-13 days). This variation was due to the selective removal of coagulation/sedimentation as well as the accumulation of captured cells over the period of storage time. However, the prediction of the cyanobacterial community composition in the SST remained a challenge. Among nutrient parameters, orthophosphate availability was related to community profile in RW samples, whereas communities in ST were influenced by total nitrogen, Kjeldahl nitrogen (N- Kjeldahl), total and particulate phosphorous, and total organic carbon (TOC). No trend was observed on the impact of nutrients on SST communities. This study profiled new health-related, environmental, and technical challenges for the production of drinking water due to the complex fate of cyanobacteria in cyanobacteria-laden sludge and supernatant.
Collapse
|
26
|
Diversity Assessment of Toxic Cyanobacterial Blooms during Oxidation. Toxins (Basel) 2020; 12:toxins12110728. [PMID: 33233813 PMCID: PMC7699887 DOI: 10.3390/toxins12110728] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 10/28/2020] [Accepted: 11/18/2020] [Indexed: 12/11/2022] Open
Abstract
Fresh-water sources of drinking water are experiencing toxic cyanobacterial blooms more frequently. Chemical oxidation is a common approach to treat cyanobacteria and their toxins. This study systematically investigates the bacterial/cyanobacterial community following chemical oxidation (Cl2, KMnO4, O3, H2O2) using high throughput sequencing. Raw water results from high throughput sequencing show that Proteobacteria, Actinobacteria, Cyanobacteria and Bacteroidetes were the most abundant phyla. Dolichospermum, Synechococcus, Microcystis and Nostoc were the most dominant genera. In terms of species, Dolichospermum sp.90 and Microcystis aeruginosa were the most abundant species at the beginning and end of the sampling, respectively. A comparison between the results of high throughput sequencing and taxonomic cell counts highlighted the robustness of high throughput sequencing to thoroughly reveal a wide diversity of bacterial and cyanobacterial communities. Principal component analysis of the oxidation samples results showed a progressive shift in the composition of bacterial/cyanobacterial communities following soft-chlorination with increasing common exposure units (CTs) (0–3.8 mg·min/L). Close cyanobacterial community composition (Dolichospermum dominant genus) was observed following low chlorine and mid-KMnO4 (287.7 mg·min/L) exposure. Our results showed that some toxin producing species may persist after oxidation whether they were dominant species or not. Relative persistence of Dolichospermum sp.90 was observed following soft-chlorination (0.2–0.6 mg/L) and permanganate (5 mg/L) oxidation with increasing oxidant exposure. Pre-oxidation using H2O2 (10 mg/L and one day contact time) caused a clear decrease in the relative abundance of all the taxa and some species including the toxin producing taxa. These observations suggest selectivity of H2O2 to provide an efficient barrier against toxin producing cyanobacteria entering a water treatment plant.
Collapse
|
27
|
Unravelling the importance of the eukaryotic and bacterial communities and their relationship with Legionella spp. ecology in cooling towers: a complex network. MICROBIOME 2020; 8:157. [PMID: 33183356 PMCID: PMC7664032 DOI: 10.1186/s40168-020-00926-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Accepted: 09/20/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND Cooling towers are a major source of large community-associated outbreaks of Legionnaires' disease, a severe pneumonia. This disease is contracted when inhaling aerosols that are contaminated with bacteria from the genus Legionella, most importantly Legionella pneumophila. How cooling towers support the growth of this bacterium is still not well understood. As Legionella species are intracellular parasites of protozoa, it is assumed that protozoan community in cooling towers play an important role in Legionella ecology and outbreaks. However, the exact mechanism of how the eukaryotic community contributes to Legionella ecology is still unclear. Therefore, we used 18S rRNA gene amplicon sequencing to characterize the eukaryotic communities of 18 different cooling towers. The data from the eukaryotic community was then analysed with the bacterial community of the same towers in order to understand how each community could affect Legionella spp. ecology in cooling towers. RESULTS We identified several microbial groups in the cooling tower ecosystem associated with Legionella spp. that suggest the presence of a microbial loop in these systems. Dissolved organic carbon was shown to be a major factor in shaping the eukaryotic community and may be an important factor for Legionella ecology. Network analysis, based on co-occurrence, revealed that Legionella was correlated with a number of different organisms. Out of these, the bacterial genus Brevundimonas and the ciliate class Oligohymenophorea were shown, through in vitro experiments, to stimulate the growth of L. pneumophila through direct and indirect mechanisms. CONCLUSION Our results suggest that Legionella ecology depends on the host community, including ciliates and on several groups of organisms that contribute to its survival and growth in the cooling tower ecosystem. These findings further support the idea that some cooling tower microbiomes may promote the survival and growth of Legionella better than others. Video Abstract.
Collapse
|
28
|
Near real-time notification of water quality impairments in recreational freshwaters using rapid online detection of β-D-glucuronidase activity as a surrogate for Escherichia coli monitoring. THE SCIENCE OF THE TOTAL ENVIRONMENT 2020; 720:137303. [PMID: 32145611 DOI: 10.1016/j.scitotenv.2020.137303] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2019] [Revised: 02/12/2020] [Accepted: 02/12/2020] [Indexed: 06/10/2023]
Abstract
Waterborne disease outbreaks associated with recreational waters continue to be reported around the world despite existing microbiological water quality monitoring frameworks. Most regulations resort to the use of culture-based enumeration of faecal indicator bacteria such as Escherichia coli to protect bathers from gastrointestinal illness risks. However, the long sample-to-result time of standard culture-based assays (minimum 18-24 h) and infrequent regulatory sampling (weekly or less) do not enable detection of episodic water quality impairments and associated public health risks. The objective of this study was to assess the suitability of an autonomous online technology measuring β-D-glucuronidase (GLUC) activity for near real-time monitoring of microbiological water quality in recreational waters and for the resulting beach management decisions. GLUC activity and E. coli concentrations were monitored at three freshwater sites in Quebec, Canada (sites Qc1-3) and one site in New Zealand (site NZ) between 2016 and 2018. We found site-dependent linear relationships between GLUC activity and E. coli concentrations and using confusion matrices, we developed site-specific GLUC activity beach action values (BAVs) matching the regulatory E. coli BAVs. Using the regulatory E. coli BAV as the gold standard, rates of false alarms (unnecessary beach advisories using GLUC activity BAV) and failures to act (failure to trigger advisories using GLUC activity) ranged between 0 and 32% and between 3 and 10%, respectively, which is comparable to the rates reported in other studies using qPCR-defined BAVs. However, a major benefit of the autonomous enzymatic technology is the real-time reporting of threshold exceedances, while temporal trends in GLUC activity can assist in understanding the underlying dynamics of faecal pollution and potential health risks. Our study is the first to describe the applicability of online near real-time monitoring of microbiological water quality as a tool for improved beach management and public health protection.
Collapse
|
29
|
Can routine monitoring of E. coli fully account for peak event concentrations at drinking water intakes in agricultural and urban rivers? WATER RESEARCH 2020; 170:115369. [PMID: 31830653 DOI: 10.1016/j.watres.2019.115369] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/01/2019] [Revised: 11/25/2019] [Accepted: 12/02/2019] [Indexed: 06/10/2023]
Abstract
In several jurisdictions, the arithmetic mean of Escherichia coli concentrations in raw water serves as the metric to set minimal treatment requirements by drinking water treatment plants (DWTPs). An accurate and precise estimation of this mean is therefore critical to define adequate requirements. Distributions of E. coli concentrations in surface water can be heavily skewed and require statistical methods capable of characterizing uncertainty. We present four simple parametric models with different upper tail behaviors (gamma, log-normal, Lomax, mixture of two log-normal distributions) to explicitly account for the influence of peak events on the mean concentration. The performance of these models was tested using large E. coli data sets (200-1800 samples) from raw water regulatory monitoring at six DWTPs located in urban and agricultural catchments. Critical seasons of contamination and hydrometeorological factors leading to peak events were identified. Event-based samples were collected at an urban DWTP intake during two hydrometeorological events using online β-d-glucuronidase activity monitoring as a trigger. Results from event-based sampling were used to verify whether selected parametric distributions predicted targeted peak events. We found that the upper tail of the log-normal and the Lomax distributions better predicted large concentrations than the upper tail of the gamma distribution. Weekly sampling for two years in urban catchments and for four years in agricultural catchments generated reasonable estimates of the average raw water E. coli concentrations. The proposed methodology can be easily used to inform the development of sampling strategies and statistical indices to set site-specific treatment requirements.
Collapse
|
30
|
Presence of Legionella spp. in cooling towers: the role of microbial diversity, Pseudomonas, and continuous chlorine application. WATER RESEARCH 2020; 169:115252. [PMID: 31726393 DOI: 10.1016/j.watres.2019.115252] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2019] [Revised: 10/23/2019] [Accepted: 10/27/2019] [Indexed: 05/25/2023]
Abstract
Legionnaires' disease (LD) is a severe pneumonia caused by several species of the genus Legionella, most frequently by Legionella pneumophila. Cooling towers are the most common source for large community-associated outbreaks. Colonization, survival, and proliferation of L. pneumophila in cooling towers are necessary for outbreaks to occur. These steps are affected by the chemical and physical parameters of the cooling tower environment. We hypothesize that the bacterial community residing in the cooling tower could also affect the presence of L. pneumophila. A 16S rRNA gene targeted amplicon sequencing approach was used to study the bacterial community of cooling towers and its relationship with the Legionella spp. and L. pneumophila communities. The results indicated that the water source shaped the bacterial community of cooling towers. Several taxa were enriched and positively correlated with Legionella spp. and L. pneumophila. In contrast, Pseudomonas showed a strong negative correlation with Legionella spp. and several other genera. Most importantly, continuous chlorine application reduced microbial diversity and promoted the presence of Pseudomonas creating a non-permissive environment for Legionella spp. This suggests that disinfection strategies as well as the resident microbial population influences the ability of Legionella spp. to colonize cooling towers.
Collapse
|
31
|
Assessing microbial risk through event-based pathogen loading and hydrodynamic modelling. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 693:133567. [PMID: 31374504 DOI: 10.1016/j.scitotenv.2019.07.373] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2019] [Revised: 06/17/2019] [Accepted: 07/22/2019] [Indexed: 06/10/2023]
Abstract
The aim of this study was to assess the variability of microbial risk associated with drinking water under various contaminant loading conditions in a drinking water source. For this purpose, a probabilistic-deterministic approach was applied to estimate the loadings of Cryptosporidium, Giardia, and Escherichia coli (E. coli) from fecal contamination sources during both dry and wet weather conditions. The relative importance of loads originating from various fecal contamination sources was also determined by a probabilistic approach. This study demonstrates that water resource recovery facilities were the dominant source of Giardia, yet rivers were more important with regards to Cryptosporidium. Estimated loadings were used as input to a three-dimensional hydrodynamic model of Lake Ontario; the fate and transport of microbial organisms were simulated at the influent of a drinking water intake. Discharge-based hydrodynamic modelling results were compared to observed concentrations. Simulated probability distributions of concentrations at the intake were used as an input to a quantitative microbial risk assessment (QMRA) model such that the variability of microbial risk in the context of drinking water could be examined. Depending on wind and currents, higher levels of fecal contamination reached the intake during wet weather loading scenarios. Probability distribution functions of Cryptosporidium, Giardia and E. coli concentrations at the intake were significantly higher during wet weather conditions when compared to dry conditions (p < 0.05). For all contaminants studied, the QMRA model showed a higher risk during wet weather (over 1 order of magnitude) compared to dry weather conditions. When considering sewage by-pass scenarios, risks remained below 2.7 × 10-7 person-1 day-1 for Giardia and E. coli O157:H7. Limited data were available for Cryptosporidium in by-pass effluents and the risk is unknown; hence it is critical to obtain reliable loading data for the riskiest scenarios, such as those associated with water resource recovery facility by-passes.
Collapse
|
32
|
Tracking the contribution of multiple raw and treated wastewater discharges at an urban drinking water supply using near real-time monitoring of β-d-glucuronidase activity. WATER RESEARCH 2019; 164:114869. [PMID: 31377523 DOI: 10.1016/j.watres.2019.114869] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Revised: 07/13/2019] [Accepted: 07/14/2019] [Indexed: 06/10/2023]
Abstract
Past waterborne outbreaks have demonstrated that informed vulnerability assessment of drinking water supplies is paramount for the provision of safe drinking water. Although current monitoring frameworks are not designed to account for short-term peak concentrations of fecal microorganisms in source waters, the recent development of online microbial monitoring technologies is expected to fill this knowledge gap. In this study, online near real-time monitoring of β-d-glucuronidase (GLUC) activity was conducted for 1.5 years at an urban drinking water intake impacted by multiple point sources of fecal pollution. Parallel routine and event-based monitoring of E. coli and online measurement of physico-chemistry were performed at the intake and their dynamics compared over time. GLUC activity fluctuations ranged from seasonal to hourly time scales. All peak contamination episodes occurred between late fall and early spring following intense rainfall and/or snowmelt. In the absence of rainfall, recurrent daily fluctuations in GLUC activity and culturable E. coli were observed at the intake, a pattern otherwise ignored by regulatory monitoring. Cross-correlation analysis of time series retrieved from the drinking water intake and an upstream Water Resource Recovery Facility (WRRF) demonstrated a hydraulic connection between the two sites. Sewage by-passes from the same WRRF were the main drivers of intermittent GLUC activity and E. coli peaks at the drinking water intake following intense precipitation and/or snowmelt. Near real-time monitoring of fecal pollution through GLUC activity enabled a thorough characterization of the frequency, duration and amplitude of peak contamination periods at the urban drinking water intake while providing crucial information for the identification of the dominant upstream fecal pollution sources. To the best of our knowledge, this is the first characterization of a hydraulic connection between a WRRF and a downstream drinking water intake across hourly to seasonal timescales using high frequency microbial monitoring data. Ultimately, this should help improve source water protection through catchment mitigation actions, especially in a context of de facto wastewater reuse.
Collapse
|
33
|
Normalized dynamic behavior of combined sewer overflow discharges for source water characterization and management. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2019; 249:109386. [PMID: 31421478 DOI: 10.1016/j.jenvman.2019.109386] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Revised: 08/05/2019] [Accepted: 08/09/2019] [Indexed: 06/10/2023]
Abstract
As one of the major sources of surface water quality impairments, Combined Sewer Overflows (CSOs) are of concern when receiving waters are used for drinking water supplies. Given the large number and variability in CSO discharges and loads, there is a need for a general methodology for estimating discharges for environmental planning and source water protection. Detailed data on CSO flowrates, contaminant concentrations including Total Suspended Solids (TSS), Escherichia coli (E. coli), caffeine (CAF) and acetaminophen (ACE) were used to develop a simple loading model that was then verified using discharge and concentration data from other CSO and stormwater events in the literature. The variability of the parameters within each event was analyzed by normalizing flowrate, concentration and event duration to their respective peak values. The normalized flowrate data indicate that the second decile of the discharge periods was associated with peak flowrates. The dynamic behavior of CSO flowrates can be characterized by a linearly increasing trend and then a logarithmically decreasing trend in terms of normalized values. The samples captured during the first decile of the events were illustrated to be a better representation of peak concentrations of all four contaminants. By analyzing the discharge period in three sections (i.e. 1st decile, 2nd decile and remainder), a semi-probabilistic CSO loading model is proposed for the entire discharge period taking into account the variability of the phenomena. Findings can help water managers and utilities to characterize their source waters for better planning and to more efficiently design sampling campaigns for capturing peak concentrations at drinking water treatment plants.
Collapse
|
34
|
Precipitation effects on parasite, indicator bacteria, and wastewater micropollutant loads from a water resource recovery facility influent and effluent. JOURNAL OF WATER AND HEALTH 2019; 17:701-716. [PMID: 31638022 DOI: 10.2166/wh.2019.054] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The variability of fecal microorganisms and wastewater micropollutants (WWMPs) loads in relation to influent flow rates was evaluated for a water resource recovery facility (WRRF) in support of a vulnerability assessment of a drinking water source. Incomplete treatment and bypass discharges often occur following intense precipitation events that represent conditions that deviate from normal operation. Parasites, fecal indicator bacteria, and WWMPs concentrations and flow rate were measured at the WRRF influent and effluent during dry and wet weather periods. Influent concentrations were measured to characterize potential bypass concentrations that occur during wet weather. Maximum influent Giardia and C. perfringens loads and maximum effluent Escherichia coli and C. perfringens loads were observed during wet weather. Influent median loads of Cryptosporidium and Giardia were 6.8 log oocysts/day and 7.9 log cysts/day per 1,000 people. Effluent median loads were 3.9 log oocysts/day and 6.3 log cysts/day per 1,000 people. High loads of microbial contaminants can occur during WRRF bypasses following wet weather and increase with increasing flow rates; thus, short-term infrequent events such as bypasses should be considered in vulnerability assessments of drinking water sources in addition to the increased effluent loads during normal operation following wet weather.
Collapse
|
35
|
Data supporting the optimization of liquid chromatography tandem mass spectrometry conditions to analyze EPA-priority hormones and bisphenol A in water samples. Data Brief 2019; 24:103958. [PMID: 31193341 PMCID: PMC6526397 DOI: 10.1016/j.dib.2019.103958] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
This database presents the optimization of ultra-high-performance liquid chromatography electrospray ionization tandem mass spectrometry (UHPLC-MS/MS) for the analysis of EPA-priority endocrine disruptor compounds (13 hormones and bisphenol A). Various method parameters were tested and compared for improved sensitivity. Data related to the selection of the ionization source (heated-ESI vs. APCI) are presented, including optimization results of source parameters. Compound-dependent responses when varying the UHPLC mobile phase salt concentration of ammonium fluoride (NH4F) are supplied. Details on the chromatographic gradient program and chromatographic data demonstrating the separation of α-estradiol and β-estradiol are provided. In addition, we supply the details on mass spectrometry parameters under the optimized conditions, relative responses of quantification and confirmation MS/MS transitions (QT/CT), and number of points present in UHPLC-MS/MS spectra. The sample preparation and instrumental analysis procedures under the retained conditions are also described. The herein dataset supports the research “Analysis of Environmental Protection Agency priority endocrine disruptor hormones and bisphenol A in tap, surface and wastewater by online concentration liquid chromatography tandem mass spectrometry” Goeury et al., 2019.
Collapse
|
36
|
Legionella pneumophila levels and sequence-type distribution in hospital hot water samples from faucets to connecting pipes. WATER RESEARCH 2019; 156:277-286. [PMID: 30925374 DOI: 10.1016/j.watres.2019.03.019] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 03/08/2019] [Accepted: 03/14/2019] [Indexed: 05/07/2023]
Abstract
Recent studies have reported increased levels of Legionella pneumophila (Lp) at points of use compared to levels in primary and secondary components of hot water systems, suggesting possible selection by environmental conditions. In this study, concentrations of Lp in a hospital hot water system were evaluated by profile sampling, collecting successive water samples to determine the prevalence at the faucet (distal) and upstream piping before and after a system intervention to increase temperature. Lp strain diversity was compared between different points of use and different areas of the hot water system (i.e., tap, intermediate piping and main upflow piping). In total, 47 isolates were recovered from 32 positive hot water samples collected from designated taps, showers and recirculation loops; these isolates were subsequently analyzed by sequence-based typing (SBT). Lp levels were comparable between first draw (500 mL) and flushed (2 and 5 min) samples, whereas a decrease was observed in the amount of culturable cells (1 log). Two sequence types (STs) were identified throughout the system. ST378 (sg4/10) was present in 91% of samples, while ST154-like (sg1) was present in 41%; both STs were simultaneously recovered in 34% of samples. Isolated STs displayed comparable tolerance to copper (0.8-5 mg/L) and temperature (55 °C, 1 h) exposure. The ability to replicate within THP1 cells and Acanthamoeba castellanii was similar between the two STs and a comparative environmental outbreak strain. The low Lp diversity and the detection of both Lp sequence types in repeated subsequent samples collected from positive faucets in a hospital wing suggest a minimal impact of the distal conditions on strain selection for the sampled points, as well as a possible adaptation to stressors present in the system, leading to the predominance of a few strains.
Collapse
|
37
|
True exposure to lead at the tap: Insights from proportional sampling, regulated sampling and water use monitoring. WATER RESEARCH 2019; 156:327-336. [PMID: 30927628 DOI: 10.1016/j.watres.2019.03.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2018] [Revised: 03/01/2019] [Accepted: 03/08/2019] [Indexed: 06/09/2023]
Abstract
This work aimed to evaluate the ability of four regulatory sampling protocols to accurately determine weekly water lead levels (WLLs) of exposure at the kitchen tap in twenty-nine households with or without a lead service line (LSL). Proportional sampling was used as the gold standard to which the other protocols, 5-min flush, 30-min stagnation, 6-h stagnation and random daytime were compared. Random daytime samples provided mean WLLs closest to true exposure in the households monitored overall compared to other sampling protocols. Strikingly, mean WLLs after 5 min of flushing underestimated lead exposure by 47%. Supporting these observations, water usage patterns revealed that full flushing only occurs in 3.4% of usage events within the service line and in 0.26% at the tap. The time between usage events in the service line was approximately 30 min but the 30-min protocol tended to slightly underestimate WLLs. These differences were explained by flushing prior to the 30-min stagnation sampling, which limited the contribution of the LSL to WLLs. Furthermore, the average stagnation at the kitchen time was 106 min and usage events rarely exceeded the water volume within premise plumbing (1.1 L). Mean WLLs after 6 h of stagnation without flushing overestimated exposure by 29% but provided a conservative indicator of WLLs of exposure.
Collapse
|
38
|
Fecal contamination of storm sewers: Evaluating wastewater micropollutants, human-specific Bacteroides 16S rRNA, and mitochondrial DNA genetic markers as alternative indicators of sewer cross connections. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 659:548-560. [PMID: 31096384 DOI: 10.1016/j.scitotenv.2018.12.378] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2016] [Revised: 12/21/2018] [Accepted: 12/24/2018] [Indexed: 06/09/2023]
Abstract
A set of fecal indicator bacteria and alternative markers were tested for their use to identify priority sectors of two urban watersheds in the Greater Montreal region with unintended household sewage connections to storm drainage systems. Analyses were performed for thermotolerant (fecal) coliforms (FC), Escherichia coli, human-specific Bacteroidales (HF183) and mitochondrial DNA (Hmt) markers, carbamazepine (CBZ), caffeine (CAF), theophylline (THEO) and acetaminophen (ACE). A high incidence of human fecal contamination was observed, illustrating the need for a method to appropriately prioritize sectors for the rehabilitation of sewer cross-connections. Concentrations of alternative markers were not significantly different between the residential and industrial/commercial/institutional (ICI) sectors. However, median E. coli concentrations were higher in the residential as compared to ICI sectors (p < 0.05). Hmt marker, CAF, and THEO were well correlated to E. coli in the ICI sector (r > 0.61, p < 0.05). Considering all sites, only CAF and THEO were correlated to E. coli (r > 0.59, p < 0.05), possibly as a result of higher E. coli inputs from other sources such as domestic animals or fauna in the residential sector. Thresholds were determined to relate alternative markers to E. coli for use in an index for prioritizing sectors with sewer cross-connections. HF183, Hmt, CAF, THEO, and ACE were identified as suitable markers for identifying sewer cross-connections and are more reliable than E. coli alone, most importantly in residential sectors.
Collapse
|
39
|
Autonomous online measurement of β-D-glucuronidase activity in surface water: is it suitable for rapid E. coli monitoring? WATER RESEARCH 2019; 152:241-250. [PMID: 30677635 DOI: 10.1016/j.watres.2018.12.060] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2018] [Revised: 12/21/2018] [Accepted: 12/22/2018] [Indexed: 06/09/2023]
Abstract
Microbiological water quality is traditionally assessed using culture-based enumeration of faecal indicator bacteria such as Escherichia coli. Despite their relative ease of use, these methods require a minimal 18-24 h-incubation step before the results are obtained. This study aimed to assess the suitability of an autonomous online fluorescence-based technology measuring β-glucuronidase (GLUC) activity for rapid near-real time monitoring of E. coli in water. The analytical precision was determined and compared to an automated microbial detection system, two culture-based assays and quantitative real-time PCR (qPCR). Using replicate measurements of grab samples containing E. coli concentrations between 50 and 2330 CFU.100 mL-1, the autonomous GLUC activity measurement technology displayed an average coefficient of variation (CV) of less than 5% that was 4-8-fold lower than other methods tested. Comparable precision was observed during online in situ monitoring of GLUC activity at a drinking water intake using three independent instruments. GLUC activity measurements were not affected by sewage or sediments at concentrations likely to be encountered during long-term monitoring. Furthermore, significant (p < 0.05) correlations were obtained between GLUC activity and the other assays including defined substrate technology (r = 0.77), membrane filtration (r = 0.73), qPCR (r = 0.55) and the automated microbial detection system (r = 0.50). This study is the first to thoroughly compare the analytical performance of rapid automated detection technologies to established culture and molecular-based methods. Results show that further research is required to correlate GLUC activity to the presence of viable E. coli as measured in terms of CFU.100 mL-1. This would allow the use of autonomous online GLUC activity measurements for rapid E. coli monitoring in water supplies used for drinking water production and recreation.
Collapse
|
40
|
Lead and copper release from full and partially replaced harvested lead service lines: Impact of stagnation time prior to sampling and water quality. WATER RESEARCH 2019; 150:380-391. [PMID: 30550868 DOI: 10.1016/j.watres.2018.11.076] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2018] [Revised: 11/20/2018] [Accepted: 11/27/2018] [Indexed: 06/09/2023]
Abstract
Partial lead service line replacement (PLSLR) results in the addition of a new galvanic connection and can increase lead concentrations at the tap. Focus has been given to minimizing lead release after PLSLR, but little information is available on the impact of lead remedial actions on copper concentrations, especially before passivation occurs. The impact of water quality (decreased chloride-to-sulfate mass ratio from 0.9 to 0.3; addition of orthoP; pH increase to 8.3) on lead and copper concentrations was investigated after stagnation (30 min-336 h) in a pipe rig comparing full lead service line (LSL), and two configurations of partial LSLs (Cu-Pb and Pb-Cu). Results show different trends for lead and copper: maximum lead concentrations were reached in 16 h while copper concentrations continued to increase over 336 h. Lead release rates were also the highest in the first 16 h of stagnation and were strongly impacted by water quality and the configuration of PLSLR (Cu-Pb vs Pb-Cu). Increasing the sampling flow rate from 5 to 15 LPM drastically increased the particulate lead release (78-fold) in Pb-Cu configurations; this effect was however not observed in 100% Pb or Cu-Pb configurations. High velocity flushing prior to 16 h stagnation decreased total Pb release by a factor of 12-fold for Cu-Pb, 1.6-fold for Pb-Cu and 2.0-fold for 100% Pb. Results support the definition of sampling protocols targeted for the detection of lead and copper sources and the proscription of flushing prior to sampling.
Collapse
|
41
|
Study of the long-term impacts of treatments on lead release from full and partially replaced harvested lead service lines. WATER RESEARCH 2019; 149:566-577. [PMID: 30508757 DOI: 10.1016/j.watres.2018.11.037] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Revised: 11/13/2018] [Accepted: 11/15/2018] [Indexed: 06/09/2023]
Abstract
Long-term (155 weeks) Pb concentrations, following partial lead service lines replacements (PLSLR), were measured in a flow through pilot made of harvested lead service lines (LSL) from the distribution system of the City of Montreal. The present study also investigates how release of Pb from full and partial LSLs is influenced by: pipe diameter, decrease in chloride-to-sulfate mass ratio (CSMR) from 0.9 to 0.3, addition of orthophosphate (1 mg P/L), and increase in pH to 8.3. Pb concentrations were measured after 16 h of stagnation and under flow conditions. In this study, Pb concentrations did not decrease, in the long term, after partial LSL replacement. Moreover, the most effective corrosion control treatment in full LSLs was the addition of orthoP. In contrast, the decrease of the CSMR best reduced lead release from partial LSLs. The impact of pipe configuration therefore influenced the effectiveness of corrosion control treatments. It is noteworthy that the increase in Pb concentrations following PLSLR were attributed to particulate Pb release from the galvanic section of the pipe. The occurrence of galvanic corrosion, caused by the connection between Pb and copper pipes, adds a new source of Pb in the partial LSL. At least, this new source of lead has to be offset by the removal of a long enough section of LSL during PLSLR. Full LSL replacements may be warranted to minimize the exposure of consumers to elevated Pb levels caused by galvanic corrosion in LSLs.
Collapse
|
42
|
Lipid composition and salt concentration as regulatory factors of the anion selectivity of VDAC studied by coarse-grained molecular dynamics simulations. Chem Phys Lipids 2018; 220:66-76. [PMID: 30448398 DOI: 10.1016/j.chemphyslip.2018.11.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2018] [Revised: 11/08/2018] [Accepted: 11/12/2018] [Indexed: 12/27/2022]
Abstract
The voltage-dependent anion channel (VDAC) is a mitochondrial outer membrane protein whose fundamental function is to facilitate and regulate the flow of metabolites between the cytosol and the mitochondrial intermembrane space. Using coarse-grained molecular dynamics simulations, we investigated the dependence of VDAC selectivity towards small inorganic anions on two factors: the ionic strength and the lipid composition. In agreement with experimental data we found that VDAC becomes less anion selective with increasing salt concentration due to the screening of a few basic residues that point into the pore lumen. The molecular dynamics simulations provide insight into the regulation mechanism of VDAC selectivity by the composition in the lipid membrane and suggest that the ion distribution is differently modulated by POPE compared to the POPC bilayer. This occurs through the more persistent interactions of acidic residues located at both rims of the β-barrel with head groups of POPE which in turn impact the electrostatic potential and thereby the selectivity of the pore. This mechanism occurs not only in POPE single component membranes but also in a mixed POPE/POPC bilayer by an enrichment of POPE over POPC lipids on the surface of VDAC. Thus we show here that computationally-inexpensive coarse-grained simulations are able to capture, in a semi-quantitative way, essential features of VDAC anion selectivity and could pave the way toward a molecular level understanding of metabolite transport in natural membranes.
Collapse
|
43
|
Sampling in schools and large institutional buildings: Implications for regulations, exposure and management of lead and copper. WATER RESEARCH 2018; 140:110-122. [PMID: 29704756 DOI: 10.1016/j.watres.2018.04.045] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Revised: 04/17/2018] [Accepted: 04/18/2018] [Indexed: 06/08/2023]
Abstract
Legacy lead and copper components are ubiquitous in plumbing of large buildings including schools that serve children most vulnerable to lead exposure. Lead and copper samples must be collected after varying stagnation times and interpreted in reference to different thresholds. A total of 130 outlets (fountains, bathroom and kitchen taps) were sampled for dissolved and particulate lead as well as copper. Sampling was conducted at 8 schools and 3 institutional (non-residential) buildings served by municipal water of varying corrosivity, with and without corrosion control (CC), and without a lead service line. Samples included first draw following overnight stagnation (>8h), partial (30 s) and fully (5 min) flushed, and first draw after 30 min of stagnation. Total lead concentrations in first draw samples after overnight stagnation varied widely from 0.07 to 19.9 μg Pb/L (median: 1.7 μg Pb/L) for large buildings served with non-corrosive water. Higher concentrations were observed in schools with corrosive water without CC (0.9-201 μg Pb/L, median: 14.3 μg Pb/L), while levels in schools with CC ranged from 0.2 to 45.1 μg Pb/L (median: 2.1 μg Pb/L). Partial flushing (30 s) and full flushing (5 min) reduced concentrations by 88% and 92% respectively for corrosive waters without CC. Lead concentrations were <10 μg Pb/L in all samples following 5 min of flushing. However, after only 30 min of stagnation, first draw concentrations increased back to >45% than values in 1st draw samples collected after overnight stagnation. Concentrations of particulate Pb varied widely (≥0.02-846 μg Pb/L) and was found to be the cause of very high total Pb concentrations in the 2% of samples exceeding 50 μg Pb/L. Pb levels across outlets within the same building varied widely (up to 1000X) especially in corrosive water (0.85-851 μg Pb/L after 30MS) confirming the need to sample at each outlet to identify high risk taps. Based on the much higher concentrations observed in first draw samples, even after a short stagnation, the first 250mL should be discarded unless no sources of lead are present. Results question the cost-benefit of daily or weekly flushing as a remediation strategy. As such, current regulatory requirements may fail to protect children as they may not identify problematic taps and effective mitigation measures.
Collapse
|
44
|
Seasonal variations of steroid hormones released by wastewater treatment plants to river water and sediments: Distribution between particulate and dissolved phases. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 635:144-155. [PMID: 29660718 DOI: 10.1016/j.scitotenv.2018.03.370] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/09/2017] [Revised: 03/06/2018] [Accepted: 03/30/2018] [Indexed: 06/08/2023]
Abstract
Extensive environmental monitoring was conducted in an urban river impacted by multiple combined sewer overflows (CSOs) and wastewater treatment plant (WWTP) discharge points. Temporal and spatial distributions of dissolved and particulate steroids (progesterone (Prog), testosterone (Testo), medroxyprogesterone (MDRXY-Prog), levonorgestrel (Levo), norethindrone (Nore), estrone (E1), estradiol (E2), estriol (E3), and 17α-ethinylestradiol (EE2)) were investigated in sewage, WWTP effluents, receiving river water and sediments, and in drinking water plant (DWP) intakes. Steroids were detected in both dissolved and particulate phases with mean concentrations from 21ngL-1 to 389ngL-1 in raw sewage and from 10ngL-1 to 296ngL-1 in treated wastewater. The particle-associated steroids represented 0-82% of their total concentration as some steroids like E1 and E3 were detected only in the dissolved phase while MDRXY-Prog (81%), Nore (71%), and EE2 (>75%) were primarily detected in the particulate phase. Particle-associated steroids were detected in spring samples from river water with mean concentrations ranging from 5.4ngL-1 to 35.7ngL-1 compare to 3ngL-1 to 6.8ngL-1 in summer samples. Levels of particle-associated Testo, Nore, E2 and Levo in DWP intakes (406.2-13,149.1ngg-1) were similar to those found in raw sewage (336.6-7628.8ngg-1), indicating their persistence in the suspended phase from discharge points. Total steroids measured in sediments were in the range of 7-1213ngg-1, 5-25ngg-1, and 22-226ngg-1 in autumn, spring, and summer, respectively. Our findings confirm the presence and seasonal variation of a mixture of particle-associated steroids in drinking water sources. The presence of high concentrations of a mixture of particle-associated steroids in DWP intakes highlight the need for highly effective particle-removal processes to eliminate these recalcitrant compounds during drinking water production. Finally, the detected concentrations raise concerns about their potential environmental effects.
Collapse
|
45
|
Lead Levels at the Tap and Consumer Exposure from Legacy and Recent Lead Service Line Replacements in Six Utilities. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2018; 52:9451-9459. [PMID: 30027743 DOI: 10.1021/acs.est.8b02388] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Profile, regulatory, and investigative sampling were completed in six utilities to study the impact of partial and full lead service line replacements (LSLRs) on water lead levels (WLLs) and consumer's exposure. As compared to households with no replacement, lead release after partial LSLR (PLSLR) was generally greater in the short term (3-50 days), and comparable or lower in the medium (<2 years) and long-term (>2 years). This was mainly explained by insufficient time elapsed to stabilize scales after disturbances to the service line. One utility showed sustained lead release over 18 months after PLSLR. Moreover, the reduction in WLLs was small when analyzing results for the same households. As a comparison, full LSLR decreased WLLs drastically and immediately. The occurrence of low (0-5 μg/L) to high (≥50 μg/L) WLLs in the profiles varied between households and reflected the variability of exposure among households in the same system. Using this probability of occurrence, the distribution of WLLs of exposure was estimated for households with or without a PLSLR, and used to model young children blood lead levels (BLLs) for both groups of households. The range of modeled BLLs decreased slightly for households with PLSLR, but still overlapped the range estimated for households with no replacement. This analysis suggests that, in a system, PLSLRs do not reduce young children blood lead levels except in a fraction of households.
Collapse
|
46
|
Impact of stagnation and sampling volume on water microbial quality monitoring in large buildings. PLoS One 2018; 13:e0199429. [PMID: 29928013 PMCID: PMC6013212 DOI: 10.1371/journal.pone.0199429] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2018] [Accepted: 06/07/2018] [Indexed: 01/22/2023] Open
Abstract
Microbial drinking water quality can be altered in large buildings, especially after stagnation. In this study, bacterial profiles were generated according to the stagnation time and the volume of water collected at the tap. Successive volumes of cold and hot water were sampled after controlled stagnation periods. Bacterial profiles revealed an important decline (> 2 log) in culturable cells in the first 500 mL sampled from the hot and cold water systems, with a steep decline in the first 15 mL. The strong exponential correlation (R2 ≥ 0.97) between the culturable cell counts in water and the pipe surface-to-volume ratio suggests the biofilm as the main contributor to the rapid increase in suspended culturable cells measured after a short stagnation of one-hour. Results evidence the contribution of the high surface-to-volume ratio at the point of use and the impact of short stagnation times on the increased bacterial load observed. Simple faucets with minimal internal surface area should be preferred to minimize surface area. Sampling protocol, including sampling volume and prior stagnation, was also shown to impact the resulting culturable cell concentration by more than 1000-fold. Sampling a smaller volume on first draw after stagnation will help maximize recovery of bacteria.
Collapse
|
47
|
A novel Eulerian approach for modelling cyanobacteria movement: Thin layer formation and recurrent risk to drinking water intakes. WATER RESEARCH 2017; 127:191-203. [PMID: 29049968 DOI: 10.1016/j.watres.2017.10.021] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2017] [Revised: 06/23/2017] [Accepted: 10/09/2017] [Indexed: 06/07/2023]
Abstract
Toxic cyanobacteria (CB) blooms are being reported in an increasing number of water bodies worldwide. As drinking water (DW) treatment can be disrupted by CB, in addition to long term management plans, short term operational decision-making tools are needed that enable an understanding of the temporal variability of CB movement in relation to drinking water intakes. In this paper, we propose a novel conservative model based on a Eulerian framework and compare results with data from CB blooms in Missisquoi Bay (Québec, Canada). The hydrodynamic model considered the effects of wind and light intensity, demonstrated that current understanding of cell buoyancy in relation to light intensity in full-scale systems is incomplete and some factors are yet to be fully characterized. Factors affecting CB buoyancy play a major role in the formation of a thin surface layer that could be of ecological importance with regards to cell concentrations and toxin production. Depending on velocities, wind contributes either to the accumulation or to the dispersion of CB. Lake recirculation effects have a tendency to create zones of low CB concentrations in a water body. Monitoring efforts and future research should focus on short-term variations of CB throughout the water column and the characterization of factors other than light intensity that affect cell buoyancy. These factors are critical for understanding the risk of breakthrough into treatment plants as well as the formation of surface scums and subsequent toxin production.
Collapse
|
48
|
Molecular Mechanisms of Drug Action: X-ray Crystallography at the Basis of Structure-based and Ligand-based Drug Design. BIOPHYSICAL TECHNIQUES IN DRUG DISCOVERY 2017. [DOI: 10.1039/9781788010016-00067] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Biological systems are recognized for their complexity and diversity and yet we sometimes manage to cure disease via the administration of small chemical drug molecules. At first, active ingredients were found accidentally and at that time there did not seem a need to understand the molecular mechanism of drug functioning. However, the urge to develop new drugs, the discovery of multipurpose characteristics of some drugs, and the necessity to remove unwanted secondary drug effects, incited the pharmaceutical sector to rationalize drug design. This did not deliver success in the years directly following its conception, but it drove the evolution of biochemical and biophysical techniques to enable the characterization of molecular mechanisms of drug action. Functional and structural data generated by biochemists and structural biologists became a valuable input for computational biologists, chemists and bioinformaticians who could extrapolate in silico, based on variations in the structural aspects of the drug molecules and their target. This opened up new avenues with much improved predictive power because of a clearer perception of the role and impact of structural elements in the intrinsic affinity and specificity of the drug for its target. In this chapter, we review how crystal structures can initiate structure-based drug design in general.
Collapse
|
49
|
Short- and Long-Term Lead Release after Partial Lead Service Line Replacements in a Metropolitan Water Distribution System. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2017; 51:9507-9515. [PMID: 28791866 DOI: 10.1021/acs.est.7b01720] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Thirty-three households were monitored in a full-scale water distribution system, to investigate the impact of recent (<2 yr) or old partial lead service line replacements (PLSLRs). Total and particulate lead concentrations were measured using repeat sampling over a period of 1-20 months. Point-of-entry filters were installed to capture sporadic release of particulate lead from the lead service lines (LSLs). Mean concentrations increased immediately after PLSLRs and erratic particulate lead spikes were observed over the 18 month post-PLSLR monitoring period. The mass of lead released during this time frame indicates the occurrence of galvanic corrosion and scale destabilization. System-wide, lead concentrations were however lower in households with PLSLRs as compared to those with no replacement, especially for old PLSLRs. Nonetheless, 61% of PLSLR samples still exceeded 10 μg/L, reflecting the importance of implementing full LSL replacement and efficient risk communication. Acute concentrations measured immediately after PLSLRs demonstrate the need for appropriate flushing procedures to prevent lead poisoning.
Collapse
|
50
|
Hospital Drains as Reservoirs of Pseudomonas aeruginosa: Multiple-Locus Variable-Number of Tandem Repeats Analysis Genotypes Recovered from Faucets, Sink Surfaces and Patients. Pathogens 2017; 6:pathogens6030036. [PMID: 28792484 PMCID: PMC5617993 DOI: 10.3390/pathogens6030036] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2017] [Revised: 08/03/2017] [Accepted: 08/04/2017] [Indexed: 12/16/2022] Open
Abstract
Identifying environmental sources of Pseudomonas aeruginosa (Pa) related to hospital-acquired infections represents a key challenge for public health. Biofilms in water systems offer protection and favorable growth conditions, and are prime reservoirs of microorganisms. A comparative genotyping survey assessing the relationship between Pa strains recovered in hospital sink biofilm and isolated in clinical specimens was conducted. Environmental strains from drain, faucet and sink-surface biofilm were recovered by a culture method after an incubation time ranging from 48 to 240 h. The genotyping of 38 environmental and 32 clinical isolates was performed using a multiple-locus variable-number of tandem repeats analysis (MLVA). More than one-third of Pa isolates were only cultivable following ≥48 h of incubation, and were predominantly from faucet and sink-surface biofilms. In total, 41/70 strains were grouped within eight genotypes (A to H). Genotype B grouped a clinical and an environmental strain isolated in the same ward, 5 months apart, suggesting this genotype could thrive in both contexts. Genotype E grouped environmental isolates that were highly prevalent throughout the hospital and that required a longer incubation time. The results from the multi-hospital follow-up study support the drain as an important reservoir of Pa dissemination to faucets, sink surfaces and patients. Optimizing the recovery of environmental strains will strengthen epidemiological investigations, facilitate pathway identification, and assist in identifying and controlling the reservoirs potentially associated to hospital-acquired infections.
Collapse
|