1
|
Multi-vendor multi-site quantitative MRI analysis of cartilage degeneration 10 Years after anterior cruciate ligament reconstruction: MOON-MRI protocol and preliminary results. Osteoarthritis Cartilage 2022; 30:1647-1657. [PMID: 36049665 PMCID: PMC9671830 DOI: 10.1016/j.joca.2022.08.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Revised: 07/12/2022] [Accepted: 08/01/2022] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To describe the protocol of a multi-vendor, multi-site quantitative MRI study for knee post-traumatic osteoarthritis (PTOA), and to present preliminary results of cartilage degeneration using MR T1ρ and T2 imaging 10 years after anterior cruciate ligament reconstruction (ACLR). DESIGN This study involves three sites and two MR platforms. The patients are from a nested cohort (termed as Onsite cohort) within the Multicenter Orthopaedic Outcomes Network (MOON) cohort 10 years after ACLR. Phantoms and controls were scanned for evaluating reproducibility. Cartilage was automatically segmented, and T1ρ and T2 were compared between operated, contralateral, and control knees. RESULTS Sixty-eight ACL-reconstructed patients and 20 healthy controls were included. In phantoms, the intra-site coefficients of variation (CVs) of repeated scans ranged 1.8-2.1% for T1ρ and 1.3-1.7% for T2. The inter-site CVs ranged 1.6-2.1% for T1ρ and 1.1-1.4% for T2. In human subjects, the intra-site scan/rescan CVs ranged 2.2-3.5% for T1ρ and 2.6-4.9% for T2 for the six major compartments. In patients, operated knees showed significantly higher T1ρ and T2 values mainly in medial femoral condyle, medial tibia and trochlear cartilage compared with contralateral knees, and showed significantly higer T1ρ and T2 values in all six compartments compared to healthy control knees. The patient contralateral knees showed higher T1ρ and T2 values mainly in the lateral femoral condyle, lateral tibia, trochlear, and patellar cartilage compared to healthy control knees. CONCLUSION A platform and workflow with rigorous quality control has been established for a multi-vendor multi-site quantitative MRI study in evaluating PTOA 10 years after ACLR. Our preliminary report suggests significant cartilage matrix changes in both operated and contralateral knees compared with healthy control knees.
Collapse
|
2
|
Donor-matched comparison of chondrogenic progenitors resident in human infrapatellar fat pad, synovium, and periosteum - implications for cartilage repair. Connect Tissue Res 2019; 60:597-610. [PMID: 31020864 DOI: 10.1080/03008207.2019.1611795] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
Purpose: There is a clinical need to better characterize tissue sources being used for stem cell therapies. This study focuses on comparison of cells and connective tissue progenitors (CTPs) derived from native human infrapatellar fatpad (IPFP), synovium (SYN), and periosteum (PERI). Materials and Methods: IPFP, SYN, PERI were harvested from twenty-eight patients undergoing arthroplasty. CTPs were quantitatively characterized using automated colony-forming-unit assay to compare total nucleated cell concentration-[Cell], cells/mg; prevalence-(PCTP), CTPs/million nucleated cells; CTP concentration-[CTP], CTPs/mg; proliferation and differentiation potential; and correlate outcomes with patient's age and gender. Results: [Cell] did not differ between IPFP, SYN, and PERI. PCTP was influenced by age and gender: patients >60 years, IPFP and SYN had higher PCTP than PERI (p < 0.001) and females had higher PCTP in IPFP (p < 0.001) and SYN (p = 0.001) than PERI. [CTP] was influenced by age: patients <50 years, SYN (p = 0.0165) and PERI (p < 0.001) had higher [CTP] than IPFP; patients between 60 and 69 years, SYN (p < 0.001) had higher [CTP] than PERI; patients >70 years, IPFP (p = 0.006) had higher [CTP] than PERI. In patients >60 years, proliferation potential of CTPs differed significantly (SYN>IPFP>PERI); however, differentiation potentials were comparable between all three tissue sources. Conclusion: SYN and IPFP may serve as a preferred tissue source for patients >60 years, and PERI along with SYN and IPFP may serve as a preferred tissue source for patients <60 years for cartilage repair. However, the heterogeneity among the CTPs in any given tissue source suggests performance-based selection might be useful to optimize cell-sourcing strategies to improve efficacy of cellular therapies for cartilage repair.
Collapse
|
3
|
Histopathological assessment of primary osteoarthritic knees in large patient cohort reveal the possibility of several potential patterns of osteoarthritis initiation. Curr Res Transl Med 2017; 65:133-139. [PMID: 29132902 PMCID: PMC5731834 DOI: 10.1016/j.retram.2017.09.002] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2017] [Revised: 09/25/2017] [Accepted: 09/26/2017] [Indexed: 12/13/2022]
Abstract
OBJECTIVE The two main objectives of the study include (1) Test the hypothesis that the lateral femoral condyle (LFC) in patients with primary OA and varus knees undergoing total knee arthroplasty (TKA) can be used as a model to better characterize varying histological features of human OA, (2) Correlate characteristic OA features using the established histopathological scoring systems (HHGS and OARSI) to understand potential histopathological patterns of OA initiation. DESIGN Two osteochondral specimens (4×4×8mm) were collected from fifty patient's LFC at the time of TKA (total 100 specimens), who presented preserved lateral knee compartment with joint space width>2mm. Three independent readers graded the sections on three different occasions using HHGS and OARSI systems. The correlation between individual parameters of the two scoring systems and their inter- and intra-reader variability, reliability and reproducibility were estimated. RESULTS All samples in this cohort showed abnormal histopathological features. Total histopathological scores of the LFC ranged from HHGS median=4.6 (range=0 to 11), and OARSI median=5.2 (range=0 to 19.5). The four individual sub-items of HHGS scoring system (structure, cells, safraninO staining, tidemark) were weakly correlated, with the correlation between structure and cellularity being the strongest (r=0.40). Both the scoring systems had similar repeatability and reproducibility coefficients of<21%. CONCLUSIONS OA changes in the LFC are not confined to any one region, and maybe seen in different regions of cartilage, tidemark, subchondral bone, and/or the marrow space vascularity. These variations may point to the possibility of several potential patterns of initiation in OA.
Collapse
|
4
|
Does the presence of focal normal marrow fat signal within a tumor on MRI exclude malignancy? An analysis of 184 histologically proven tumors of the pelvic and appendicular skeleton. Skeletal Radiol 2008; 37:797-804. [PMID: 18551289 DOI: 10.1007/s00256-008-0523-7] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2008] [Revised: 04/25/2008] [Accepted: 05/13/2008] [Indexed: 02/02/2023]
Abstract
OBJECTIVE The aim of this study was to determine if the presence of focal normal bone marrow fat signal within a tumor on magnetic resonance imaging excludes malignancy. MATERIALS AND METHODS One hundred eighty-four histologically proven tumors with available magnetic resonance imaging (MRI) of the appendicular skeleton and pelvis from 184 patients were collected and reviewed at two separate institutions. There were 111 malignant and 73 benign tumors. Two radiologists at each institution, blinded to the diagnosis, reviewed the MRIs independently and reported the presence or absence of normal marrow fat signal within the tumor based upon T1-weighted imaging without fat suppression and T2-weighted imaging with fat suppression and/or short inversion-time inversion recovery (STIR). Discrepancies were then reviewed in consensus to determine the presence or absence of focal normal marrow signal. For each institution, a Fisher's exact test was used to compare the frequency of focal normal marrow fat signal in benign and malignant tumors. This comparison was performed for each reader, as well as for the consensus reading at each site. Positive and negative predictive values were also calculated for each reader, as well as the consensus reading at each site. Fisher's exact test was also used to compare the frequency of intratumoral fat in benign and malignant lesions for the pooled sample. Bayes theorem was used to calculate the positive and negative predictive values for the pooled consensus data. Ninety-five percent confidence intervals were constructed for the pooled estimates using a bootstrapping algorithm. RESULTS There was good interobserver reliability of 95.3% and 96.7% at sites 1 and 2, respectively. There were three discrepancies (one malignant and two benign) at site 1 and four discrepancies (two malignant and two benign) at site 2. Reader consensus at site 1 identified normal marrow fat signal within 1 of 50 (2.0%) malignant and three of 14 (21.4%) benign tumors. Findings were statistically significant with a p value of 0.030. The positive predictive value (PPV) and negative predictive value (NPV) at site 1 was 81.7% and 75.0%, respectively. Reader consensus at site 2 identified normal marrow fat signal within three of 61 (4.9%) malignant and 14 of 59 (23.7%) benign tumors. Findings were statistically significant with a calculated p value of 0.004. The PPV and NPV at site 1 was 56.3% and 82.4%, respectively. For the pooled consensus, the frequency of intratumoral fat in benign lesions (17/73, 23.3%) is significantly greater than the frequency in malignant lesions (4/111, 3.6%), p < 0.001. CONCLUSION The presence of focal normal marrow signal within a tumor is highly suggestive of a benign tumor.
Collapse
|
5
|
Effects of diagnostic information, per se, on patient outcomes in acute radiculopathy and low back pain. AJNR Am J Neuroradiol 2008; 29:1098-103. [PMID: 18467522 DOI: 10.3174/ajnr.a0999] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE We conducted a prospective randomized study of patients with acute low back pain and/or radiculopathy to assess the effect of knowledge of diagnostic findings on clinical outcome. The practice of ordering spinal imaging, perhaps unintentionally, includes a large number of patients for whom the imaging test is performed for purposes of reassurance or because of patient expectations. If this rationale is valid, one would expect to see a measurable effect from diagnostic information, per se. MATERIALS AND METHODS A total of 246 patients with acute (<3 weeks) low back pain (LBP) and/or radiculopathy (150 LBP and 96 radiculopathy patients) were recruited. Patients were randomized using a stratified block design with equal allocation to either the unblinded group (MR imaging results provided within 48 hours) or the blinded group (both patient and physician blinded to MR imaging results.) After the initial MR imaging, patients followed 6 weeks of conservative management. Roland function, visual pain analog, absenteeism, Short Form (SF)-36 Health Status Survey, self-efficacy scores, and Fear Avoidance Questionnaire were completed at presentation; 2, 4, 6, and 8 weeks; and 6, 12, and 24 months. Improvement of Roland score by 50% or more and patient satisfaction assessed by Cherkin symptom satisfaction measure were considered a positive outcome. RESULTS Clinical outcome at 6 weeks was similar for unblinded and blinded patients. Self-efficacy, fear avoidance beliefs, and the SF-36 subscales were similar over time for blinded and unblinded patients, except for the general health subscale on the SF-36. General health of the blinded group improved more than for the unblinded group (P = .008). CONCLUSIONS Patient knowledge of imaging findings do not alter outcome and are associated with a lesser sense of well-being.
Collapse
|
6
|
Multi-slice computed tomography as a screening tool for colon cancer, lung cancer and coronary artery disease. Eur Radiol 2002; 11:1975-85. [PMID: 11702131 DOI: 10.1007/s003300100950] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2000] [Accepted: 03/20/2001] [Indexed: 12/01/2022]
Abstract
Recent promising trials that use low-dose CT for the early detection of lung cancer have reinvigorated the interest in screening approaches. At the same time the development of fast image acquisition techniques, such as multislice CT, have sparked renewed interest in cardiac imaging within the radiological community. In addition to special cardiac capabilities, multislice CT has several other features such as high acquisition speed and low-dose requirements that may make this modality a universal radiological screening tool. Non-invasive disease detection is the radiologist's domain. In this paper we identify criteria for effective screening and apply these criteria to screening approaches with multislice CT when used for detection of three disease entities: colon cancer; lung cancer; and cardiovascular disease.
Collapse
|
7
|
Spiral CT scanning technique in the detection of aspiration of LEGO foreign bodies. Pediatr Radiol 2001; 31:836-40. [PMID: 11727016 DOI: 10.1007/s002470100001] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/19/2001] [Accepted: 07/20/2001] [Indexed: 11/25/2022]
Abstract
BACKGROUND Radiolucent foreign bodies (FBs) such as plastic objects and toys remain difficult to identify on conventional radiographs of the neck and chest. Children may present with a variety of respiratory complaints, which may or may not be due to a FB. OBJECTIVE To determine whether radiolucent FBs such as plastic LEGOs and peanuts can be seen in the tracheobronchial tree or esophagus using low-dose spiral CT, and, if visible, to determine the optimal CT imaging technique. MATERIALS AND METHODS Multiple spiral sequences were performed while varying the CT parameters and the presence and location of FBs in either the trachea or the esophagus first on a neck phantom and then a cadaver. Sequences were rated by three radiologists blinded to the presence of a FB using a single scoring system. RESULTS The LEGO was well visualized in the trachea by all three readers (both lung and soft-tissue windowing: combined sensitivity 89 %, combined specificity 89 %) and to a lesser extent in the esophagus (combined sensitivity 31 %, combined specificity 100 %). The peanut was not well visualized (combined sensitivity < 35 %). The optimal technique for visualizing the LEGO was 120 kV, 90 mA, 3-mm collimation, 0.75 s/revolution, and 2.0 pitch. This allowed for coverage of the cadaver tracheobronchial tree (approximately 11 cm) in about 18 s. Although statistical power was low for detecting significant differences, all three readers noted higher average confidence ratings with lung windowing among 18 LEGO-in-trachea scans. CONCLUSION Rapid, low-dose spiral CT may be used to visualize LEGO FBs in the airway or esophagus. Peanuts were not well visualized.
Collapse
|
8
|
Assessing physicians' accuracy in diagnosing paediatric patients with acute abdominal pain: measuring accuracy for multiple diseases. Stat Med 2001; 20:3261-78. [PMID: 11746317 DOI: 10.1002/sim.944] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
In evaluating the accuracy of diagnostic tests there are many situations where the true disease status can be one of multiple disorders. For example, when paediatric patients suffer acute abdominal pain, the underlying diagnosis could be appendicitis, intestinal obstruction, gastroenteritis, urinary tract infection, etc. In this paper we describe a format for collecting data for the case of multiple truth states. This new format allows one to make pairwise comparisons of the diagnostic accuracy between all of the different truth states. We propose a summary measure of accuracy which is a weighted average of the pairwise estimates of accuracy. Estimators are derived for the variance and covariance of the estimated summary accuracy. The small sample properties of the estimators are evaluated in a Monte Carlo simulation study. The new data collection format and summary measure were used in a paediatric acute abdominal pain study; data from this study are used to illustrate the methods.
Collapse
|
9
|
Can electronic medical images replace hard-copy film? Defining and testing the equivalence of diagnostic tests. Stat Med 2001; 20:2845-63. [PMID: 11568944 DOI: 10.1002/sim.929] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Electronic medical images are an efficient and convenient format in which to display, store and transmit radiographic information. Before electronic images can be used routinely to screen and diagnose patients, however, it must be shown that readers have the same diagnostic performance with this new format as traditional hard-copy film. Currently, there exist no suitable definitions of diagnostic equivalence. In this paper we propose two criteria for diagnostic equivalence. The first criterion ('population equivalence') considers the variability between and within readers, as well as the mean reader performance. This criterion is useful for most applications. The second criterion ('individual equivalence') involves a comparison of the test results for individual patients and is necessary when patients are followed radiographically over time. We present methods for testing both individual and population equivalence. The properties of the proposed methods are assessed in a Monte Carlo simulation study. Data from a mammography screening study is used to illustrate the proposed methods and compare them with results from more conventional methods of assessing equivalence and inter-procedure agreement.
Collapse
|
10
|
The "differential diagnosis" for multiple diseases: comparison with the binary-truth state experiment in two empirical studies. Acad Radiol 2001; 8:947-54. [PMID: 11699847 DOI: 10.1016/s1076-6332(03)80638-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
RATIONALE AND OBJECTIVES In practice readers must often choose between multiple diagnoses. For assessing reader accuracy in these settings. Obuchowski et al have proposed the "differential diagnosis" method, which derives all pairwise estimates of accuracy for the various diagnoses, along with summary measures of accuracy. The current study assessed the correspondence between the differential diagnosis method and conventional binary-truth state experiments. MATERIALS AND METHODS Two empirical studies were conducted at two institutions with different readers and diagnostic tests. Readers used the differential diagnosis format to interpret a set of cases. In subsequent readings they interpreted the cases in binary-truth state experiments. Spearman rank correlation coefficients and the percentages of agreement in scores were computed, and the areas under the receiver operating characteristic curves were estimated and compared. RESULTS The between-format Spearman rank correlation coefficients were 0.697-0.718 and 0.750-0.780 for the two studies; the between-reader correlations were 0.417 and 0.792, respectively. The percentages of agreement between formats for the two studies were 50.0%-51.7% and 72.9%-78.8%; the percentages of agreement between readers were 45.0% and 80%, respectively. In the first study there were several significant differences in the areas under receiver operating characteristic curves; in the second study these differences were small. CONCLUSION The differences observed between the two formats can be attributed to within-reader variability and inherent differences in the questions posed to readers in the multiple-diagnoses versus binary-truth state reading sessions. The differential diagnosis format is useful for estimating accuracy when there are multiple possible diagnoses.
Collapse
|
11
|
|
12
|
Abstract
RATIONALE AND OBJECTIVES The purpose of this study was to evaluate a completely automatic method, based on Kittler's optimal threshold, to estimate breast density by using the mammographers' definition. MATERIALS AND METHODS Thirty-two normal, right-craniocaudal-view mammograms of women aged 37-86 years were digitized. The whole breast area was segmented by using Kittler's optimal threshold procedure, and the dense portions were then segmented by using a modified version of Kittler's method. Segmentation results were validated by three independent mammographers who provided a signed percentage (in steps of 5%) to indicate the difference between their own visual estimation of the dense portions and the results obtained with the algorithm. The difference between the algorithm measurements and the mammographers' measurements was compared to the interobserver differences. RESULTS A high correlation was found between the algorithm measured density and the mammographers' measurements. Spearman correlations ranged from 0.92 to 0.95 (P < .001). Algorithm-measured density differed from the mammographers' measurements by an average of 6.9% (ie, average of the absolute differences). In contrast, mammographers' measurements differed between themselves by an average of 5.4%. CONCLUSION The difference between density as measured with the algorithm and as measured by the mammographers is similar to the differences observed between mammographers. This algorithm could be useful in providing clinically accurate estimates of breast density.
Collapse
|
13
|
Abstract
OBJECTIVE I provide researchers with tables of sample size for multiobserver receiver operating characteristic (ROC) studies that compare the diagnostic accuracies of two imaging techniques. MATERIALS AND METHODS I computed the number of patients and observers needed as a function of five parameters: the measure of diagnostic accuracy (area under the ROC curve, sensitivity at a false-positive rate </= 0.10, or specificity at a false-negative rate </= 0.10), conjectured level of accuracy, suspected difference in accuracy between the two imaging techniques, observer variability, and ratio of patients without to patients with the condition. RESULTS The numbers of patients and observers required vary dramatically with these five parameters, increasing with more refined measures of accuracy, with lower accuracy levels, with smaller suspected differences, with greater observer variability, and with less balanced designs. The number of patients required for a study can be reduced by increasing the number of observers, and vice versa. When the intra- and interobserver variability is large, a study design with just four observers is usually inadequate. CONCLUSION Many factors must be considered when determining the appropriate sample sizes for multiobserver ROC studies. My tables serve only as initial ballpark estimates. Investigators should compute sample size using parameters that reflect their clinical application.
Collapse
|
14
|
Abstract
OBJECTIVE The objective of this study was to compare the performance of four image enhancement algorithms on secondarily digitized (i.e., digitized from film) mammograms containing masses and microcalcifications of known pathology in a clinical soft-copy display setting. MATERIALS AND METHODS Four different image processing algorithms (adaptive unsharp masking, contrast-limited adaptive histogram equalization, adaptive neighborhood contrast enhancement, and wavelet-based enhancement) were applied to one image of secondarily digitized mammograms of forty cases (10 each of benign and malignant masses and 10 each of benign and malignant microcalcifications). The four enhanced images and the one unenhanced image were displayed randomly across three high-resolution monitors. Four expert mammographers ranked the unenhanced and the four enhanced images from 1 (best) to 5 (worst). RESULTS For microcalcifications, the adaptive neighborhood contrast enhancement algorithm was the most preferred in 49% of the interpretations, the wavelet-based enhancement in 28%, and the unenhanced image in 13%. For masses, the unenhanced image was the most preferred in 58% of cases, followed by the unsharp masking algorithm (28%). CONCLUSION Appropriate image enhancement improves the visibility of microcalcifications. Among the different algorithms, the adaptive neighborhood contrast enhancement algorithm was preferred most often. For masses, no significant improvement was observed with any of these image processing approaches compared with the unenhanced image. Different image processing approaches may need to be used, depending on the type of lesion. This study has implications for the practice of digital mammography.
Collapse
|
15
|
Abstract
RATIONALE AND OBJECTIVES In assessing diagnostic accuracy it is often essential to determine the reader's ability both to detect and to correctly locate multiple abnormalities per patient. The authors developed a new approach for the detection and localization of multiple abnormalities and compared it with other approaches. MATERIALS AND METHODS The new approach involves partitioning the image into multiple regions of interest (ROIs). The reader assigns a confidence score to each ROI. Statistical methods for clustered data are used to assess and compare reader accuracy. The authors applied this new method to a reader-performance study of conventional film images and digitized images used to detect and locate malignant breast cancer lesions. RESULTS The ROI-based approach, the free-response receiver operating characteristic (FROC) curve, and the patient-based approach handle the estimation of the false-positive rate (FPR) quite differently. These differences affect the measures of the respective areas under the curves. In the ROI-based approach the denominator is the number of ROIs without a malignant lesion. In the FROC approach the average number of false-positive findings per patient is plotted on the x axis of the curve. In contrast, the patient-based approach mishandles the FPR by ignoring multiple detection and/or localization errors in the same patient. The FROC approach does not lend itself easily to statistical evaluations. CONCLUSION The ROI-based approach appropriately captures both the detection and localization tasks. The interpretation of the ROI-based accuracy measures is simple and clinically relevant. There are statistical methods for estimating and comparing ROI-based estimates of accuracy.
Collapse
|
16
|
Abstract
RATIONALE AND OBJECTIVES The authors compared diagnostic accuracy and callback rates with conventional screen-film mammograms and wavelet-compressed digitized images. MATERIALS AND METHODS Sixty sets of mammograms (four views per case) were digitized at a spatial resolution of 100 microm. The images were wavelet compressed to a mean compression ratio of 8:1 and reviewed by three mammographers. Five regions were evaluated in each breast. Suspicion of malignancy was graded on a scale of 0% to 100%, and receiver operating characteristic (ROC) analysis was performed. Callback rates were calculated by using the American College of Radiology's Breast Imaging Reporting and Data System lexicon scale. RESULTS The mean diagnostic accuracy with compressed and conventional images was 0.832 and 0.860, respectively. The upper 95% confidence bound for the difference in ROC areas was 0.061. The mean false-positive rate at a fixed sensitivity of 0.90 was 0.041 for compressed images and 0.059 for conventional images. The mean callback rates for normal, benign, and malignant regions were 0.023, 0.305, and 0.677, respectively, for compressed images and 0.036, 0.447, and 0.750, respectively, for conventional images. The upper 95% confidence bound for the (absolute) differences in callback rates was 0.012 for normal regions, 0.163 for benign regions, and 0.138 for malignant regions. CONCLUSION Diagnostic accuracies were equivalent for both compressed and conventional images. The mean false-positive rate at fixed sensitivity was much better with the compressed images. However, the callback rates for malignant lesions were lower when the compressed images were used.
Collapse
|
17
|
Abstract
RATIONALE AND OBJECTIVES The authors evaluated the relationship between a woman's breast parenchymal density and her age by means of a quantitative method for measuring density from digitized mammograms. MATERIALS AND METHODS The percentage of the breast considered to be dense was evaluated from mammograms of 50 women stratified by age. Quantitative analysis based on the computer segmentation of tissue in digitized mammograms was performed by three expert mammographers. The results of this analysis were compared with results from a review of the film mammograms by three expert mammographers. RESULTS A slight decrease in the percentage of breast considered to be dense with increased age was observed. The average difference in the percentage of dense breast tissue between the youngest and the oldest age groups was 6.4% based on the digital review and 14.6% based on the film review. Within each age group, the total variability was on the order of 75%. CONCLUSION The difference in mean magnitude between the youngest and oldest age groups was small and may not be clinically important. The variability within an age group was large, which suggests that age is not a reliable indicator of percentage of dense breast tissue.
Collapse
|
18
|
Abstract
OBJECTIVE The purpose of this study was to determine whether diagnostic accuracy and callback rates using digitized film images are equivalent to those using film-screen mammograms. MATERIALS AND METHODS Sixty sets of mammograms (four views per case) were digitized at a spatial resolution of 100 microm. The images were reviewed by seven mammographers. Five regions were evaluated in each breast. Each region was scored on a scale of 0 100% for suspicion of malignancy, and a receiver operating characteristic analysis was performed. Callback rates were calculated using a published lexicon scale. RESULTS The observers' mean diagnostic accuracies using films and digitized images were 0.872 and 0.848, respectively. The upper 95% confidence boundary on the difference in accuracy was 0.066. The mean callback rate for normal, benign, and malignant areas using films versus digitized images was 0.048 versus 0.055, 0.498 versus 0.441, and 0.786 versus 0.737, respectively. The upper 95% confidence boundary for the absolute difference in callback rates was 0.037, 0.026, and 0.130 for normal, benign, and malignant areas, respectively. CONCLUSION The diagnostic accuracies of the digitized images and films were similar; however, an increase in callback rates of 0.037 (i.e., upper 95% confidence boundary) for normal results and a reduction in the callback rates of 0.130 for malignant lesions is important. The use of digitized film images, at a spatial resolution of 100 microm, may compromise patient treatment in clinical practice.
Collapse
|
19
|
|
20
|
Correlation of valve closing to visualization of single-leg separation in radiographic images of Björk-Shiley convexo-concave heart valves. THE JOURNAL OF HEART VALVE DISEASE 1999; 8:399-403. [PMID: 10461239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/13/2023]
Abstract
BACKGROUND AND AIM OF THE STUDY The study goal was to determine whether the visualization of single-leg separation (SLS) in cineangiographic sequences of Björk-Shiley convexo-concave heart valves could be correlated to the position of the occluder disk within the cardiac cycle. METHODS Images from ten patient cases with SLS valves were reviewed by three experts, who identified the image frames within a cine sequence that appeared suspicious for SLS. The position of the occluder disk, the frame rate, and the length of the cardiac cycle were noted relative to these image frames. RESULTS The probability of detecting a SLS was not significantly correlated to any of these factors. CONCLUSIONS Visualization of SLS in cineangiographic images is limited to a few frames within an imaging sequence. It appears that other features within the image play a larger role in a clinician's ability to detect a fracture than do the cardiac dynamics of the system.
Collapse
|
21
|
Abstract
Methods for determining sample size for studies of the accuracy of diagnostic tests are reviewed. Several accuracy indices are considered, including sensitivity and specificity, the full and partial area under the receiver operating characteristic curve, the sensitivity at a fixed false positive rate, and the likelihood ratio. Sample size formulae are presented for studies evaluating a single test and studies comparing the accuracy of tests. Four real examples illustrate the concepts involved in sample size determination. Lastly, various study design issues are discussed, such as sampling methods, choices in format for the test results, and the issue of replicated readings.
Collapse
|
22
|
Abstract
RATIONALE AND OBJECTIVES The authors performed this study to address two practical questions. First, how large does the sample size need to be for confidence intervals (CIs) based on the usual asymptotic methods to be appropriate? Second, when the sample size is smaller than this threshold, what alternative method of CI construction should be used? MATERIALS AND METHODS The authors performed a Monte Carlo simulation study where 95% CIs were constructed for the receiver operating characteristic (ROC) area and for the difference between two ROC areas for rating and continuous test results--for ROC areas of moderate and high accuracy--by using both parametric and nonparametric estimation methods. Alternative methods evaluated included several bootstrap CIs and CIs with the Student t distribution. RESULTS For the difference between two ROC areas, CIs based on the asymptotic theory provided adequate coverage even when the sample size was very small (20 patients). In contrast, for a single ROC area, the asymptotic methods do not provide adequate CI coverage for small samples; for ROC areas of high accuracy, the sample size must be large (more than 200 patients) for the asymptotic methods to be applicable. The recommended alternative (bootstrap percentile, bootstrap t, or bootstrap bias-corrected accelerated method) depends on the estimation approach, format of the test results, and ROC area. CONCLUSION Currently, there is not a single best alternative for constructing CIs for a single ROC area for small samples.
Collapse
|
23
|
Abstract
McNemar's test is often used to compare two proportions estimated from paired observations. We propose a method extending this to the case where the observations are sampled in clusters. The proposed method is simple to implement and makes no assumptions about the correlation structure. We conducted a Monte Carlo simulation study to compare the size and power of the proposed method with a test developed earlier by Eliasziw and Donner. In the presence of intracluster correlation, the size of McNemar's test can greatly exceed the nominal level. The size of Eliasziw and Donner's test is also inflated for some correlation patterns. The proposed method, on the other hand, is close to the nominal size for a variety of correlation patterns, although it is slightly less powerful than Eliasziw and Donner's procedure. The proposed method is a good alternative to Eliasziw and Donner's test when, in practice, little is known about the correlation pattern of the data.
Collapse
|
24
|
Right ventricular arrhythmia in the absence of arrhythmogenic dysplasia: MR imaging of myocardial abnormalities. Radiology 1998; 207:743-51. [PMID: 9609899 DOI: 10.1148/radiology.207.3.9609899] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate right ventricular abnormalities with magnetic resonance (MR) imaging in patients with arrhythmia but without arrhythmogenic dysplasia. MATERIALS AND METHODS In 53 patients being evaluated for right ventricular arrhythmia and 15 control subjects, MR imaging was performed to evaluate fixed thinning, fatty replacement, or reduced systolic wall thickening or motion. A diagnosis of idiopathic right ventricular outflow tract tachycardia or indeterminate was assigned for each patient, and the severity of arrhythmia was categorized. RESULTS Right ventricular abnormalities were revealed in 32 (60%) of the 53 patients: fixed thinning in 27 (84%), fatty replacement in eight (25%), and reduced wall thickening or motion in 31 (97%). Right ventricular abnormalities were found in 35 (76%) of 46 patients with idiopathic right ventricular outflow tract tachycardia and in seven (39%) of 18 patients with indeterminate diagnoses (P = .022). CONCLUSION Mild right ventricular abnormalities are likely sources for arrhythmias, even in the absence of arrhythmogenic right ventricular dysplasia.
Collapse
|
25
|
Abstract
PURPOSE Daily portable chest radiographs are routinely ordered in many institutions after thoracic surgery. Our purpose was to assess the efficacy and cost of this practice and to determine the optimum use of postoperative x-ray studies. METHODS A prospective review of all portable chest x-ray films after 100 consecutive elective thoracotomies (DRG 75) was conducted. Each x-ray study initiated a three-part survey. First, the surgeon listed whether the x-ray study was routine and the anticipated management had it not been available. The radiologist then interpreted and scored the x-ray study as follows: negative, expected findings; A, minor findings necessitating no intervention; B, minor findings necessitating intervention; or C, major findings necessitating intervention. Finally, the x-ray film and the interpretation were returned to the surgeon. Any interventions necessitated by the x-ray study were recorded. RESULTS In 6 months, 99 patients underwent 82 pulmonary resections and 18 other major procedures. In the postoperative period, 769 portable chest x-ray studies were ordered, median five per patient (range 2 to 49). Of these, 731 (95%) were routine and 38 (5%), nonroutine. Severity scores were as follows: negative in 106 (13.8%), A in 558 (72.5%), B in 59 (7.7%), and C in 46 (6.0%). X-ray findings altered management in 43 of 769 studies (5.6%): in 33 routine (4.5%), in 10 nonroutine (26.3%), in 13 A (2.3%), in 22 B (37.3%), and in 8 C (17.4%). CONCLUSIONS These results demonstrate that routine daily portable chest x-ray studies have a minimal impact on management. It is, in fact, nonroutine x-ray studies that more often alter management. Had routine portable chest x-ray studies, which cost $114 each in our institution, been limited to one immediately after the operation, only 133 such studies (100 routine and 33 nonroutine) would have been needed in the care of these patients. Elimination of 636 (82.7%) x-ray studies reduces the cost of care by $725 per patient ($286,000 annually). For major thoracic procedures, it is safe, efficacious, and cost effective to eliminate routine postoperative portable chest x-ray studies and order nonroutine portable studies only when clinically indicated.
Collapse
|
26
|
Comparison of double-phase 99mTc-sestamibi with 123I-99mTc-sestamibi subtraction SPECT in hyperparathyroidism. AJR Am J Roentgenol 1997; 169:1671-4. [PMID: 9393188 DOI: 10.2214/ajr.169.6.9393188] [Citation(s) in RCA: 66] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
OBJECTIVE Our purpose was to compare double-phase 99mTc-sestamibi single-photon emission computed tomography (SPECT) and simultaneous 123I-99mTc-sestamibi subtraction SPECT for preoperative localization of hyperfunctioning parathyroid tissue in patients with primary hyperparathyroidism. SUBJECTS AND METHODS Fifteen patients with primary hyperparathyroidism underwent preoperative double-phase 99mTc-sestamibi SPECT and simultaneous 123I-99mTc-sestamibi subtraction SPECT imaging. At surgery, the location, weight, and histopathologic evaluation of all identified parathyroid glands were recorded. RESULTS At surgery, 17 parathyroid adenomas and 37 normal parathyroid glands were identified. The sensitivity, specificity, and diagnostic accuracy for the detection of parathyroid adenomas were 88%, 97%, and 94%, respectively, for simultaneous 123I-99mTc-sestamibi subtraction SPECT and 53%, 86%, and 76%, respectively, for double-phase 99mTc-sestamibi SPECT. The differences in sensitivity and diagnostic accuracy were statistically significant (p = .031 and p = .016, respectively). CONCLUSION Compared with double-phase 99mTc-sestamibi SPECT, simultaneous 123I-99mTc-sestamibi subtraction SPECT is a superior imaging study for the preoperative localization of hyperfunctioning parathyroid tissue.
Collapse
|
27
|
Abstract
PURPOSE To determine if Doppler ultrasound (US) measurements of systolic velocity in the common carotid artery vary markedly with distance from the bifurcation. MATERIALS AND METHODS Bilateral, insonation angle-corrected velocity was measured with US in the common carotid artery. Measurements were obtained 1, 2, 3, 4, and 5 cm from the carotid artery bifurcation in 20 volunteers (aged 25-43 years) with no history of neurologic or cardiovascular disease. RESULTS Velocity in the common carotid artery increased with distance (toward the aorta) from the bifurcation (mean increase, 9 cm/sec for each centimeter of distance from the bifurcation, up to the 4-cm distance; P < .001). Velocity increased more rapidly in subjects who were younger (P < .001) and in those with a lower pulse rate (P = .001). CONCLUSION The distance from the bifurcation at which common carotid artery velocity is measured should be standardized. This may increase the accuracy of the systolic velocity ratio for assessment of internal carotid artery stenosis and decrease some of the reported variability between different centers that perform US of the carotid artery.
Collapse
|
28
|
Segmented three-dimensional echo-planar flow imaging of the cervical carotid arteries. AJNR Am J Neuroradiol 1997; 18:1339-47. [PMID: 9282867 PMCID: PMC8338008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
PURPOSE To implement and assess the application of segmented three-dimensional echo-planar MR imaging time-of-flight flow sequences for studying the anatomy of the cervical carotid arteries at 1.5 T. METHODS The 3-D echo-planar sequences were segmented along the in-plane phase-encoding direction. Echo train lengths (ETLs) of 3 and 5 and signal bandwidths of +/-25, +/-33, and +/-50 KHz were tested along with a conventional (ETL = 1) 3-D MR flow study in six healthy volunteers and in five patients with known arteriosclerotic disease involving the carotid bifurcation as confirmed by conventional angiography. The volunteer data were used to rank the techniques with respect to vessel dimension, vessel/background contrast, and quality by four trained neuroradiologists. For the patient studies, the percentage of stenoses was measured for all MR studies and compared against the conventional angiographic data using the criteria of the North American Symptomatic Carotid Endarterectomy Trial. RESULTS Using Wilcoxon's test statistic and a significance level of .05, we found that the conventional MR flow examination was better than the segmented techniques and that the segmented techniques with ETL of 3 were superior to their counterparts with ETL of 5. For the ETL of 3 techniques, the high-bandwidth studies were inferior to their lower bandwidth counterparts; however, there was no significant difference between the performance of the medium- and low-bandwidth sequences. The patient data revealed that the segmented techniques consistently overestimated the severity of stenosis; however, in no instance did any of the segmented examinations erroneously indicate the presence of disease. CONCLUSIONS The reduction in acquisition time and the zero false-positive rate we obtained suggest that segmented 3-D echo-planar MR flow techniques may be used as a screening/locating study for cervical carotid artery disease.
Collapse
|
29
|
Abstract
Receiver operating characteristic (ROC) curves and their associated indices are valuable tools for the assessment of the accuracy of diagnostic tests. The area under the ROC curve is a popular summary measure of the accuracy of a test. The full area under the ROC curve, however, has been criticized because it gives equal weight to all false positive error rates. Alternative indices include the area under the ROC curve in a particular range of false positive rates ('partial' area) and the sensitivity of the test for a single fixed false positive rate (FPR). We present a unified approach for computing sample size for binormal ROC curves and their indices. Our method uses Taylor series expansions to derive approximate large-sample estimates of the variance and covariance of binormal ROC curve parameters. Several examples from diagnostic radiology illustrate the proposed method.
Collapse
|
30
|
Abstract
BACKGROUND AND PURPOSE Several recent clinical trials have shown that endarterectomy is efficacious in patients with asymptomatic carotid artery stenosis. The purpose of this study was to evaluate the effectiveness of various test strategies for screening and diagnosing carotid artery disease. METHODS We constructed a model of the natural history of carotid artery disease using literature-based estimates of the prevalence and incidence of carotid artery stenosis and associated morbidity and mortality. Markov cohort simulation was used to estimate the mean quality-adjusted life years and monetary costs associated with various management strategies. RESULTS Screening is cost-effective in the baseline model. Key parameters affecting the efficacy of screening are prevalence of operable lesions, benefit of surgery, surgical complication rates, quality of life with stroke, rate of stenosis progression, and excess morbidity and mortality. CONCLUSIONS Asymptomatic patients with carotid bruits may benefit from screening if the prevalence rate is > or = 20%, the benefits and risks associated with surgery are similar to those observed in the Asymptomatic Carotid Atherosclerosis Study, and the quality of life with stroke is considerably lower than the quality of life without stroke. Ultrasound followed by three-dimensional time-of-flight MR angiography, if indicated, is a promising test strategy.
Collapse
|
31
|
Nonparametric analysis of clustered ROC curve data. Biometrics 1997; 53:567-78. [PMID: 9192452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Current methods for estimating the accuracy of diagnostic tests require independence of the test results in the sample. However, cases in which there are multiple test results from the same patient are quite common. In such cases, estimation and inference of the accuracy of diagnostic tests must account for intracluster correlation. In the present paper, the structural components method of DeLong, DeLong, and Clarke-Pearson (1988, Biometrics 44, 837-844) is extended to the estimation of the Receiver Operating Characteristics (ROC) curve area for clustered data, incorporating the concepts of design effect and effective sample size used by Rao and Scott (1992, Biometrics 48, 577-585) for clustered binary data. Results of a Monte Carlo simulation study indicate that the size of statistical tests that assume independence is inflated in the presence of intracluster correlation. The proposed method, on the other hand, appropriately handles a wide variety of intracluster correlations, e.g., correlations between true disease statuses and between test results. In addition, the method can be applied to both continuous and ordinal test results. A strategy for estimating sample size requirements for future studies using clustered data is discussed.
Collapse
|
32
|
Preliminary experience with double-phase SPECT using Tc-99m sestamibi in patients with hyperparathyroidism. Clin Nucl Med 1997; 22:217-21. [PMID: 9099475 DOI: 10.1097/00003072-199704000-00001] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND There is a continual search for a better imaging modality for parathyroid pathology. In recent years, Tc-99m sestamibi has been proposed as an alternative to T1-201 for parathyroid scintigraphy. The purpose of this study is to assess the usefulness of a double-phase Tc-99m sestamibi SPECT technique for parathyroid imaging. METHODS Sixty-one consecutive patients with hyperparathyroidism were studied. Sixteen had previously undergone unsuccessful surgery for hyperparathyroidism. SPECT imaging of the neck and chest was performed at 15 minutes and again at 2 hours after 20-25 mCi of Tc-99m sestamibi was given intravenously. A positive scan was defined as a region of increased focal uptake that persisted on the delayed images. RESULTS When compared with surgical findings, double-phase sestamibi SPECT correctly identified 55% (26/ 47) of the parathyroid adenomas in the previously unoperated group, and 91% (10/11) of the parathyroid adenomas in the reoperative group. Double-phase sestamibi SPECT was negative in 92% (109/118) of the normal parathyroid glands in the previously unoperated group, and in 88% (15/17) in the reoperative group. CONCLUSIONS These preliminary data suggest that double-phase Tc-99m sestamibi SPECT is a promising procedure for the preoperative detection and localization of hyperfunctioning parathyroid tissue, especially in patients with recurrent or persistent postoperative hyperparathyroidism.
Collapse
|
33
|
|
34
|
Abstract
PURPOSE We studied which set of CT parameters and modeling parameters yielded accurate measurements of three graded artificial renal artery stenoses. METHOD An acrylic phantom resembling the abdominal aorta and renal arteries was constructed. Stenotic segments had diameters of 1.8, 3.2, and 4.8 mm; nonstenotic segment diameter was 6.3 mm. Helical scans were done using 1 and 3 mm collimation at pitches of 1, 1.5, and 2. 3D renderings were produced and measured. Multifactorial and regression tree analysis were used to determine the accuracy of the 3D renderings. Mean squared error (MSE) was used to compare true diameter with measured diameter. RESULTS Collimation of 1 mm produced an MSE of 0.55 versus an MSE of 1.35 for 3 mm collimation. Stenosis grade was the next most important parameter in the 1 mm subgroup and viewing direction in the 3 mm collimation subgroup. In the 1 mm subgroup, high and mid grade stenoses had an MSE of 0.52 versus low grade stenosis that had an MSE of 0.61. Pitch was a fourth-order effect. CONCLUSION Collimation of 1 mm combined with a pitch ratio as high as 2:1 is superior to 3 mm collimation. Shaded surface modeling was the single best choice for rendering 3D data. Stenosis grade interacted strongly with user-controllable parameters.
Collapse
|
35
|
Abstract
BACKGROUND As of January 31, 1995, 564 outlet strut fractures (OSFs) of Björk-Shiley convexo-concave (BSCC) heart valves had been reported to the Shiley Heart Valve Research Center, of which approximately two thirds resulted in the death of the patient. Previous studies indicate that one leg of the outlet strut separates (single-leg separation, SLS) from the valve before the second leg breaks, which results in complete OSF. To identify those valves at risk of complete OSF, an in vivo radiographic imaging technique is being developed to evaluate the strut leg integrity. The goal of the present study was to develop an objective postprocessing technique to evaluate outlet strut leg integrity quantitatively in these cineradiographic images. METHODS AND RESULTS Twenty-two sets (12 intact valves, 10 SLS valves) of cineangiographic images were obtained from individuals whose valve status was subsequently verified ex vivo. Several quantitative measures of SLS were evaluated to identify possible loss of metal or gaps in the SLS legs. Two of these measures, decrease in pixel intensity (DIPI) ratio and gap half-width, are diagnostic metrics of SLS: i.e., the maximum likelihood estimate of the area under the receiver operating characteristic curve was 0.892 (SD, 0.066) for a model based on DIPI ratio and 0.802 (SD, 0.093) for gap half-width. CONCLUSIONS We have developed a postprocessing technique that can be used to objectively evaluate outlet strut integrity in cineradiographic images of BSCC heart valves. At an estimated specificity of 1.0, the estimated sensitivity of the objective review was comparable to that of a subjective expert review panel.
Collapse
|
36
|
Comparison of FDG-PET and sestamibi-SPECT in primary hyperparathyroidism. J Nucl Med 1996; 37:1809-15. [PMID: 8917180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
UNLABELLED Preoperative localization of hyperfunctioning parathyroid tissue in patients with primary hyperparathyroidism has been a longstanding diagnostic challenge. This study directly compared FDG-PET and sestamibi-SPECT for preoperative detection of abnormal parathyroid tissue. METHODS Twenty-one consecutive patients with primary hyperparathyroidism were studied prospectively before surgical neck exploration. SPECT of the neck and chest was performed at 15 min and 2 hr after intravenous 99mTc-sestamibi. Regional body PET was performed 45 min after intravenous FDG. RESULTS Surgery revealed 19 solitary parathyroid adenomas, 2 parathyroid adenomas in one patient; and 3 hyperplastic parathyroid glands in one patient, and 51 normal parathyroid glands. The diagnostic sensitivities for detection of parathyroid adenomas of 43% (9 of 21) for dual-phase sestamibi-SPECT and 86% (18 of 21) for FDG-PET were significantly different (p < 0.001). The difference in diagnostic specificities of 78% (40 of 51) for FDG-PET and 90% (46 of 51) for dual-phase sestamibi-SPECT approached statistical significance (p = 0.063). CONCLUSION This study demonstrates that FDG-PET is more sensitive than sestamibi-SPECT in the preoperative localization of parathyroid adenomas in patients with primary hyperparathyroidism.
Collapse
|
37
|
Abstract
The goal of this study was to develop a technique to distinguish benign and malignant breast lesions in secondarily digitized mammograms. A set of 51 mammograms (two views/patient) containing lesions of known pathology were evaluated using six different morphological descriptors: circularity, mu R/sigma R (where mu R = mean radial distance of tumor boundary, sigma R = standard deviation); compactness, P2/A (where P = perimeter length of tumor boundary and A = area of the tumor); normalized moment classifier; fractal dimension; and a tumor boundary roughness (TBR) measurement (the number of angles in the tumor boundary with more than one boundary point divided by the total number of angles in the boundary). The lesion was segmented from the surrounding background using an adaptive region growing technique. Ninety-seven percent of the lesions were segmented using this approach. An ROC analysis was performed for each parameter and the results of this analysis were compared to each other and to those obtained from a subjective review by two board-certified radiologists who specialize in mammography. The results of the analysis indicate that all six parameters are diagnostic for malignancy with areas under their ROC curves ranging from 0.759 to 0.928. We observed a trend towards increased specificity at low false-negative rates (0.01 and 0.001) with the TBR measurement. Additionally, the diagnostic accuracy of a classification model based on this parameter was similar to that of the subjective reviewers.
Collapse
|
38
|
Abstract
PURPOSE To evaluate acromial shape in relation to age, sex, symmetry, and presence of subacromial enthesophytes. MATERIALS AND METHODS Three hundred ninety-four cadaveric scapulas were reviewed. Specimens were categorized by sex and age (age range, 20-89 years). Acromial morphology was typed according to the Bigliani classification: type I, flat; type II, curved; and type III, hooked. The presence and degree of subacromial enthesopathy was recorded. Selective radiographic correlation was obtained. RESULTS The relative percentages of acromial types I, II, and III were 22.8% (90 acromions), 68.5% (270 acromions), and 8.6% (34 acromions), respectively. There was a greater percentage of type III in men (10.2% [21 of 205] vs 6.9% [13 of 189] and type I in women (27.5% [52 of 189] vs 18.5% [38 of 205]). There was no relationship between acromial type and age (P = .667). Enthesophytes were most common in type III (20 [59%] of 34 acromions) versus type II (115 [42.6%] of 270 acromions) and type I (22 [24%] of 90 acromions). Acromial morphology was symmetric in 135 (70.7%) of 191 pairs of acromions and asymmetric in 56 pairs (29.3%). CONCLUSION Acromial shape does not vary significantly with age. It does, however, differ between sexes. The relative percentages of the types differ from previously reported values. Acromial shape tends to be symmetric. A trend between acromial type and the presence of enthesophytes is observed.
Collapse
|
39
|
Intraoperative evaluation of renal cell carcinoma: a prospective study of the role of ultrasonography and histopathological frozen sections. J Urol 1996; 155:1191-5. [PMID: 8632528 DOI: 10.1016/s0022-5347(01)66211-6] [Citation(s) in RCA: 67] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
PURPOSE Nephron sparing surgery is being performed increasingly for treatment of renal cell carcinoma, including in select patients with a normal contralateral kidney. The number of tumors in the involved kidney (single versus multiple) and presence or absence of perinephric fat involvement (pathological stage T1 to 2 versus T3A) are important prognostic factors. In a prospective study we evaluated the accuracy of intraoperative histopathological frozen section analysis of renal capsular biopsies for assessing local tumor stage, and the accuracy of intraoperative ultrasonography for assessing tumor focality. MATERIALS AND METHODS Intraoperative frozen section biopsies and ultrasonography were compared with information obtained from preoperative computerized tomography (CT), intraoperative inspection of the kidney by the surgeon and permanent histopathological specimens. RESULTS We evaluated 99 patients (102 kidneys) with localized sold renal masses undergoing either radical nephrectomy (48) or nephron sparing surgery (54). Final pathological analysis revealed 95 renal cell carcinomas (stage T3A in 24), 6 oncocytomas and 1 angiomyolipoma. Multiple tumors were detected in 18 of 102 kidneys overall. Frozen section analysis identified 87% of the stage T3A lesions with no false-positive results, compared to CT, which only identified 67%. Ultrasonography identified 14 of 18 multifocal tumors (78%) and was not more accurate than the combination of CT and intraoperative inspection. However, during nephron sparing surgery ultrasonography was useful to localize the intrarenal extent of tumors (17 cases). CONCLUSIONS Our results clarify the role of intraoperative ultrasonography and frozen section analysis in patients undergoing nephron sparing surgery for renal cell carcinoma. Frozen section analysis may be useful in select patients with small peripheral tumors who are under consideration for elective nephron sparing surgery.
Collapse
|
40
|
Abstract
Multiple-reader study designs have become popular in the radiology literature. We reviewed the major papers published in the American Journal of Roentgenology in the first 4 months of each of the years 1990 and 1995. The review was restricted to prospective studies of image interpretation. In the 1990 literature, we noted eight multiple-reader and 18 single-reader studies; in contrast, in the 1995 literature, we found 29 multiple-reader and eight single-reader studies. This trend reflects an increased awareness of the importance of multiple-reader studies. We examined the Results sections of the 29 multiple-reader studies from 1995 to assess the authors' motives for incorporating such a design. In 16 studies (55%), readers independently interpreted all images. However, the authors usually reported only the average interpretation of the readers; in only seven of the 29 studies (24%) did the authors describe differences among readers' interpretations. In 13 studies, interpretations were performed exclusively through "consensus reading." The method(s) used to achieve a consensus often were not explained. Only two of the 29 studies had more than three readers. In contrast, all of these studies included multiple patients. The average patient sample size was 45. Furthermore, differences observed among patients were routinely reported and/or depicted.
Collapse
|
41
|
Left ventricular outflow tract obstruction in hypertrophic cardiomyopathy: presurgical and postsurgical evaluation by computed tomography magnetic resonance imaging. AMERICAN JOURNAL OF CARDIAC IMAGING 1996; 10:1-13. [PMID: 8680128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Along with hypertrophy of the left ventricle (LV), hypertrophic cardiomyopathy (HC) is characterized by LV outflow tract (LVOT) obstruction, partly from systolic anterior motion (SAM) of the anterior mitral leaflet; if obstruction is significant, excision of excess subaortic septal myocardium may be indicated. In this study, the ability of computed tomography magnetic resonance imaging (Cine MRI) to provide information about LVOT obstruction was assessed in a series of 37 HC cases undergoing evaluation, including echocardiography (0 to 14 days before), for possible septal myectomy; in 4 cases, Cine MRI was used postsurgically (5 to 25 months after). Blinded to echocardiography results, 3 reviewers analyzed by consensus the Cine-MRI LVOT-long-axis image-loops for SAM grade (none, mild, severe) and "aorta:LVOT signal ratio" (intensity in descending aorta/intensity in LVOT at maximum systolic-flow disturbance). Resting LVOT flow velocities were separately determined using Doppler analysis, permitting differentiation between insignificant (< 30 mm Hg) and significant (< or = 30 mm Hg) gradients. With echocardiography, significant resting obstruction was found in 62% of cases, including 92% treated surgically. A significant association between SAM grade and obstruction was found; all cases with a SAM grade of none had insignificant ([-] predictive value: 100%) and most with a severe grade had significant ([+] predictive value: 78%) obstruction. Signal ratio in the absence of a significant gradient was significantly lower than in its presence; a significant linear relationship between aorta:LVOT signal ratio and resting gradient was found: LVOT gradient = ([2.9] x [signal ratio]) + 22.8. SAM grade did not contribute significantly in obstruction categorization when signal ratio was known. In all cases studied after surgery, SAM grade had decreased from severe to insignificant levels and aorta:LVOT signal ratio had been significantly reduced. Insights into the dynamic nature of the LVOT in HC patients can be provided by Cine MRI, either during their evaluation for surgery or after their septal myectomy.
Collapse
|
42
|
The safety and effectiveness of brain arteriovenous malformation embolization using acrylic and particles: the experiences of a single institution. Neurosurgery 1995; 37:606-15; discussion 615-8. [PMID: 8559287 DOI: 10.1227/00006123-199510000-00002] [Citation(s) in RCA: 66] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
The purpose of this article is to report on the safety and effectiveness of brain arteriovenous malformation (AVM) embolization for two series of patients, of which one was treated with particulate embolization and the other with acrylic embolization. Sixty-five consecutive patients from embolization logs and patient records from 1988 to 1993 were reviewed. AVMs were routinely treated with particulate embolization early in the review (1988-1991), and after a transition period, the technique was changed to acrylic embolization for the remainder of the study period (1992-1993). All patients were treated with the ultimate goal of complete AVM obliteration. AVMs were embolized and resected, if possible, and if unresectable, they were reduced in size with embolization and radiated. The course of treatment for each patient was reviewed. The effectiveness at the end of treatment was analyzed for the ability to resect the AVM and, if unresectable, the ability to reduce the AVM to radiation size. Additionally, the safety of each embolization technique was evaluated in the context of comprehensive care, in terms of the safety of the procedure itself, the surgical resection after embolization, and the outcome at the end of comprehensive treatment. This article outlines the safety and effectiveness of acrylic and particulate embolization at a single institution. The ability to surgically resect an AVM after embolization and to reduce nidus size with acrylic was at least comparable with that with particulate embolization. Comprehensive complication rates were lower after acrylic embolization and were heavily influenced by a decreased number of surgical complications in the acrylic series. These data support the need to conduct a randomized prospective clinical trial to compare the relative safety and effectiveness of the two methods of embolization.
Collapse
|
43
|
Abstract
OBJECTIVE This study was done to compare the slice sensitivity profiles (SSP) for combinations of collimation, pitch, and table speed for spiral CT using a point response phantom. The goal was to determine the optimal combination of parameters to reduce partial volume averaging without compromising z-axis coverage. MATERIALS AND METHODS A copper ball bearing measuring 0.4 mm was embedded in a closed-cell air-foam background to create a point response input phantom. The phantom was scanned at pitches from 0.1 to 2.0 for collimations of 5, 8, and 10 mm. The full width half maximums (FWHMs) and full width tenth maximums (FWTMs) were estimated from SSP curves generated by plotting the maximum pixel value in HU for each reconstructed image against table position. FWHMs and FWTMs were compared separately for constant collimation and increasing table speed and for constant table speed and decreasing collimation using either a two-tailed z-test or chi-square test. RESULTS Differences between FWHMs and between FWTMs for comparisons made between different collimations at constant table speeds of 8 and 10 mm/s were significantly different (p < or = 0.0001). Differences between FWHMs and between FWTMs showed a linear trend, increasing with increasing pitch for constant collimation (p < or = 0.0013). CONCLUSION Scanning at narrower collimation but higher pitch provides a narrower SSP when scanning at equivalent table speeds without compromising z-axis coverage.
Collapse
|
44
|
Abstract
RATIONALE AND OBJECTIVES Traditionally, multireader receiver operating characteristic (ROC) studies have used a "paired-case, paired-reader" design. The statistical power of such a design for inferences about the relative accuracies of the tests was assessed and compared with alternative designs. METHODS The noncentrality parameter of an F statistic was used to compute power as a function of the reader and patient sample sizes and the variability and correlation between readings. RESULTS For a fixed-power and Type I error rate, the traditional design reduces the number of verified cases required. A hybrid design, in which each reader interprets a different sample of patients, reduces the number of readers, total readings, and reading required per reader. The drawback is a substantial increase in the number of verified cases. CONCLUSION The ultimate choice of study design depends on the nature of the tests being compared, limiting resources, a priori knowledge of the magnitude of the correlations and variability and logistic complexity.
Collapse
|
45
|
Current implications for the efficacy of noninvasive screening for occult intracranial aneurysms in patients with a family history of aneurysms. J Neurosurg 1995; 83:42-9. [PMID: 7782848 DOI: 10.3171/jns.1995.83.1.0042] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
Although the technology exists for accurate noninvasive screening for intracranial aneurysms, the efficacy of screening depends on several key parameters of the natural history of aneurysms. Recent studies suggest that the prevalence of intracranial aneurysms may reach 20% in the subpopulation of patients with a family history of these lesions; other key parameters are less certain. The authors investigated factors that impact the efficacy of screening to establish interim guidelines. Three plausible models for the natural history of aneurysms were constructed. For each model the monetary cost of screening and the average gain in life expectancy were computed for a range of screening ages and prevalence rates. It is shown that the efficacy of screening depends on the pattern of aneurysm rupture. If aneurysms develop and rupture rapidly, then screening has no benefit. On the other hand, if aneurysms remain at risk for some time after formation, then screening may improve average life expectancy depending on when it occurs. The authors recommend that patients with a positive family history of aneurysms who are 30 years of age or younger be screened. This recommendation is based on the belief that the gains attributable to screening, assuming a constant rupture rate, outweigh the losses attributable to screening using a decreasing rupture rate model.
Collapse
|
46
|
Abstract
PURPOSE To prospectively study clinical findings and contrast material-enhanced magnetic resonance (MR) images over time in patients with acute lumbar radiculopathy. MATERIALS AND METHODS Twenty-five patients underwent physical examination and MR imaging at presentation, 6 weeks, and 6 months. Initial symptoms and clinical course were correlated with type, size, location, and enhancement of disk herniations. RESULTS Eighteen patients had a herniated nucleus pulposus (HNP) at one or more levels, two had synovial cysts and stenosis, and five had normal findings. Patients with an HNP had marginally more severe neurologic symptoms than did patients without an HNP (P = .07) at presentation. Twenty-two patients completed the 6-week examinations and 14 patients the 6-month examinations; three patients were eliminated from the study after surgical treatment. Among HNPs larger than 6 mm, substantial reduction in size was noted in 36% at 6 weeks and in more than 60% at 6 months after presentation. CONCLUSION Agreement between clinical and MR findings for level and side of HNP and radicular symptoms was excellent. There was no correlation of pain and disability with disk size, behavior, or type.
Collapse
|
47
|
Abstract
PURPOSE To determine if calcification in the intervertebral disk is associated with hyperintensity on T1-weighted spin-echo magnetic resonance (MR) images. MATERIALS AND METHODS Sagittal T1-weighted MR images that showed one or more hyperintense intervertebral disks and correlative computed tomographic (CT) scans, plain radiographs, or both, were obtained in 11 patients retrospectively and in 43 patients prospectively. Six patients underwent MR imaging with a fat-suppression technique. Histologic analysis of two disks was performed. RESULTS Absence of calcification was associated with disks that were isointense relative to normal disks (P < .001), mild to moderate calcification was associated with hyperintense disks (P < .001 and P = .004 [two readers]), and both mild to moderate and marked calcifications were associated with hypointense disks (P < .001). Fat suppression resulted in a decrease in hyperintense signal in two patients. CONCLUSION The results indicate that hyperintensity is associated with calcification. In the absence of clinical findings that suggest other causes, hyperintense disks are suggestive of degenerative disk disease.
Collapse
|
48
|
Multireader, multimodality receiver operating characteristic curve studies: hypothesis testing and sample size estimation using an analysis of variance approach with dependent observations. Acad Radiol 1995; 2 Suppl 1:S22-9; discussion S57-64, S70-1 pas. [PMID: 9419702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
49
|
Thoracic aortic disease: evaluation using a single MRA volume series. J Comput Assist Tomogr 1994; 18:843-54. [PMID: 7962788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
OBJECTIVE Use of MRA for thoracic aortic disease (TAD) evaluation has been limited. This report describes an initial experience with TAD evaluation using a single MRA volume series. MATERIALS AND METHODS A single volume series, based on sequential 2D TOF MRA, was acquired in 30 cases (28 with suspected TAD and 2 normals). Each series was processed using multiplanar reconstruction (MPR) and maximum intensity projection (MIP); resulting tomographic (one base and two MPR) and MIP sets were blindly interpreted by four reviewers to detect TAD and, if present, to diagnose its specific form. For cases incorrectly interpreted, the standard MR images were subsequently interpreted. RESULTS The TAD categories included aneurysm (n = 13), dissection (n = 9), and arch anomalies (n = 5). Sensitivities were high for TAD overall (89-100%) and TAD in ascending and descending portions; sensitivities were lower for TAD of the arch (two of four reviewers > or = 90% for TAD overall and descending TAD). Specificities for TAD overall had a wider range (67-100%), but were high for ascending, arch, and descending portions (three to four of four reviewers > or = 90% for each). Sensitivities for aneurysms (69-92%) and dissections overall (67-100%) were comparable, as they were in ascending and arch portions; descending dissection was better detected than descending aneurysm (two of four reviewers > or = 90% for ascending or arch aneurysm and for descending dissection); overall specificities (88-100 vs. 81-95%) and specificities in ascending, arch, and descending portions were also comparable (three to four of four reviewers > or = 90% for both in each portion; two of four reviewers > or = 90% for dissection overall). Each reviewer achieved > or = 70% diagnostic accuracy for TAD (one of four reviewers = 85%); accuracies for each category were comparable. Interpretation of standard MR images corrected all detection and most diagnostic (> or = 63%) errors. CONCLUSION This initial experience with conventional TOF MRA for TAD evaluation is encouraging, but it indicates the potential for advancements in data acquisition and/or postprocessing.
Collapse
|
50
|
Efficacy of endovascular treatment of meningiomas: evaluation with matched samples. AJNR Am J Neuroradiol 1994; 15:1675-80. [PMID: 7847212 PMCID: PMC8333711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
PURPOSE To evaluate the clinical efficacy, cost-effectiveness, and safety of presurgical devascularization of meningiomas. METHODS Matched samples of embolized and nonembolized groups of meningiomas were compared. The study variables for clinical efficacy were estimated blood loss, number of transfusions, surgical resection time, and length of hospitalization. The cost-effectiveness was evaluated by adjusting all hospital costs to 1991 dollar amounts, and adding additional embolization costs and fees to the hospital cost totals for the embolized group. A qualitative comparison of complications was made. RESULTS All dependent variables evaluating the clinical efficacy of the procedure (estimate blood loss, 533 cc versus 836 cc; number of transfusions, 0.39 units versus 1.56 units; surgical resection time, 305.8 minutes versus 337.5 minutes; and length of hospitalization, 10.6 days versus 15.0 days) displayed trends of higher means in the nonembolized group; however, only the estimated blood loss and number of transfusions variables were significant. The cost-effectiveness of the procedure was not statistically significant. The mean cost was $29,605 for the embolized group and $38,449 for the nonembolized group. There were three major and nine minor complications in the nonembolized group and zero major and six minor complications in the embolized group. There were four additional minor complications caused by the embolization procedure. CONCLUSION Endovascular devascularization of meningiomas is beneficial for large meningiomas because it diminishes the necessity of intraoperative transfusions and decreases blood loss. The additional day of hospitalization, emolization costs, and costs of complications do not conversely increase treatment costs. There were no major complications or adverse long-term effects caused by the embolization procedure.
Collapse
|