1
|
Ongaro A, Varani K, Masieri FF, Pellati A, Massari L, Cadossi R, Vincenzi F, Borea PA, Fini M, Caruso A, De Mattei M. Electromagnetic fields (EMFs) and adenosine receptors modulate prostaglandin E(2) and cytokine release in human osteoarthritic synovial fibroblasts. J Cell Physiol 2012; 227:2461-9. [PMID: 21830213 DOI: 10.1002/jcp.22981] [Citation(s) in RCA: 73] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Synovial fibroblasts (SFs) contribute to the development of osteoarthritis (OA) by the secretion of a wide range of pro-inflammatory mediators, including cytokines and lipid mediators of inflammation. Previous studies suggest that electromagnetic fields (EMFs) may represent a potential therapeutic approach to limit cartilage degradation and control inflammation associated to OA, and that they may act through the adenosine pathway. Therefore, we investigated whether EMFs might modulate inflammatory activities of human SFs from OA patients (OASFs) treated with interleukin-1β (IL-1β), and the possible involvement of adenosine receptors (ARs) in mediating EMF effects. EMF exposure induced a selective increase in A(2A) and A(3) ARs. These increases were associated to changes in cAMP levels, indicating that ARs were functionally active also in EMF-exposed cells. Functional data obtained in the presence of selective A(2A) and A(3) adenosine agonists and antagonists showed that EMFs inhibit the release of prostaglandin E(2) (PGE(2)) and the proinflammatory cytokines interleukin-6 (IL-6) and interleukin-8 (IL-8), while stimulating the release of interleukin-10 (IL-10), an antinflammatory cytokine. These effects seem to be mediated by the EMF-induced upregulation of A(2A) and A(3) ARs. No effects of EMFs or ARs have been observed on matrix degrading enzyme production. In conclusion, this study shows that EMFs display anti-inflammatory effects in human OASFs, and that these EMF-induced effects are in part mediated by the adenosine pathway, specifically by the A(2A) and A(3) AR activation. Taken together, these results open new clinical perspectives to the control of inflammation associated to joint diseases.
Collapse
Affiliation(s)
- A Ongaro
- Department of Morphology and Embryology, University of Ferrara, Ferrara, Italy.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
2
|
Capone F, Dileone M, Profice P, Pilato F, Musumeci G, Ranieri F, Cadossi R, Florio L, Di Iorio R, Di Lazzaro V. P22.5 Extremely low frequency magnetic fields (ELF-MF) produce functional changes in human brain. Clin Neurophysiol 2011. [DOI: 10.1016/s1388-2457(11)60566-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
3
|
Abstract
Short intense electrical pulses transiently increase the permeability of the cell membrane, an effect known as electroporation. This can be combined with antiblastic drugs for ablation of tumours of the skin and subcutaneous tissue. The aim of this study was to test the efficacy of electroporation when applied to bone and to understand whether the presence of mineralised trabeculae would affect the capability of the electric field to porate the membrane of bone cells. Different levels of electrical field were applied to the femoral bone of rabbits. The field distribution and modelling were simulated by computer. Specimens of bone from treated and control rabbits were obtained for histology, histomorphometry and biomechanical testing. After seven days, the area of ablation had increased in line with the number of pulses and/or with the amplitude of the electrical field applied. The osteogenic activity in the ablated area had recovered by 30 days. Biomechanical testing showed structural integrity of the bone at both times. Electroporation using the appropriate combination of voltage and pulses induced ablation of bone cells without affecting the recovery of osteogenic activity. It can be an effective treatment in bone and when used in combination with drugs, an option for the treatment of metastases.
Collapse
Affiliation(s)
- M Fini
- Laboratory of Preclinical and Surgical Studies, Research Institute Codivilla Putti, Rizzoli Orthopaedic Institute, via di Barbiano 1/10, 40136 Bologna, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
4
|
Fontanesi G, Monte AD, Rinaldi E, Traina GC, Mammi GI, Giancecchi F, Rotini R, Poli G, Negri V, Virgili B, Cadossi R. The Effect of Low Frequency Pulsing Electromagnetic Fields for the Treatment of Congenital and Acquired Pseudoarthroses: the Italian Group for the Study of the Effects of LFPEFs in Orthopaedics. ACTA ACUST UNITED AC 2009. [DOI: 10.1080/15368378409035965] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
5
|
Bolognani L, Notari PL, Cadossi R, Magnani C, Venturelli T, Volpi N. Effect of Low-Frequency Electromagnetic Pulsed Field Stimulation on Yeast Fermentation in Presence of Dicarboxylic and Tricarboxylic Acids. ACTA ACUST UNITED AC 2009. [DOI: 10.3109/15368379409030696] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
6
|
Cantini M, Cossarizza A, Bersani F, Cadossi R, Ceccherelli G, Tenconi R, Gatti C, Franceschi C. Enhancing Effect of Low Frequency Pulsed Electromagnetic Fields on Lectin-Induced Human Lymphocyte Proliferation. ACTA ACUST UNITED AC 2009. [DOI: 10.3109/15368378609027720] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
7
|
Jeran M, Zaffuto S, Moratti A, Bagnacani M, Cadossi R. Pemf Stimulation of Skin Ulcers of Venous Origin in Humans Preliminary Report of a Double Blind Study. ACTA ACUST UNITED AC 2009. [DOI: 10.3109/15368378709027737] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
8
|
Emilia G, Torelli G, Ceccherelli G, Donelli A, Ferrari S, Zucchini P, Cadossi R. Effect of Low-Frequency Low-Energy Pulsing Electromagnetic Fields on the Response to Lectin Stimulation of Human Normal and Chronic Lymphocytic Leukemia Lymphocytes. ACTA ACUST UNITED AC 2009. [DOI: 10.3109/15368378509040369] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
9
|
Capone F, Dileone M, Profice P, Pilato F, Musumeci G, Minicuci G, Ranieri F, Cadossi R, Setti S, Tonali PA, Di Lazzaro V. Does exposure to extremely low frequency magnetic fields produce functional changes in human brain? J Neural Transm (Vienna) 2009; 116:257-65. [PMID: 19189041 DOI: 10.1007/s00702-009-0184-2] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2008] [Accepted: 01/09/2009] [Indexed: 12/13/2022]
Abstract
Behavioral and neurophysiological changes have been reported after exposure to extremely low frequency magnetic fields (ELF-MF) both in animals and in humans. The physiological bases of these effects are still poorly understood. In vitro studies analyzed the effect of ELF-MF applied in pulsed mode (PEMFs) on neuronal cultures showing an increase in excitatory neurotransmission. Using transcranial brain stimulation, we studied noninvasively the effect of PEMFs on several measures of cortical excitability in 22 healthy volunteers, in 14 of the subjects we also evaluated the effects of sham field exposure. After 45 min of PEMF exposure, intracortical facilitation produced by paired pulse brain stimulation was significantly enhanced with an increase of about 20%, while other parameters of cortical excitability remained unchanged. Sham field exposure produced no effects. The increase in paired-pulse facilitation, a physiological parameter related to cortical glutamatergic activity, suggests that PEMFs exposure may produce an enhancement in cortical excitatory neurotransmission. This study suggests that PEMFs may produce functional changes in human brain.
Collapse
Affiliation(s)
- F Capone
- Institute of Neurology, Università Cattolica, L.go A. Gemelli 8, 00168, Rome, Italy
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
De Mattei M, Varani K, Masieri FF, Pellati A, Ongaro A, Fini M, Cadossi R, Vincenzi F, Borea PA, Caruso A. Adenosine analogs and electromagnetic fields inhibit prostaglandin E2 release in bovine synovial fibroblasts. Osteoarthritis Cartilage 2009; 17:252-62. [PMID: 18640059 DOI: 10.1016/j.joca.2008.06.002] [Citation(s) in RCA: 71] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2007] [Accepted: 06/07/2008] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To investigate the role of adenosine analogs and electromagnetic field (EMF) stimulation on prostaglandin E(2) (PGE(2)) release and cyclooxygenase-2 (COX-2) expression in bovine synovial fibroblasts (SFs). METHODS SFs isolated from synovia were cultured in monolayer. Saturation and binding experiments were performed by using typical adenosine agonists: N6-cyclohexyladenosine (CHA, A(1)), 2-[p-(2-carboxyethyl)-phenetyl-amino]-5'-N-ethylcarboxamidoadenosine (CGS 21680, A(2A)), 5'-N-ethylcarboxamidoadenosine (NECA, non-selective), N6-(3-iodobenzyl)2-chloroadenosine-5'-N-methyluronamide (Cl-IB-MECA, A(3)). SFs were treated with TNF-alpha (10 ng/ml) and lipopolysaccharide (LPS) (1 microg/ml) to activate inflammatory response. Adenosine analogs were added to control and TNF-alpha- or LPS-treated cultures both in the absence and in the presence of adenosine deaminase (ADA) which is used to deplete endogenous adenosine. Parallel cultures were exposed to EMFs (75 Hz, 1.5 mT) during the period in culture (24h). PGE(2) release was measured by immunoassay. COX-2 expression was evaluated by RT-PCR. RESULTS TNF-alpha and LPS stimulated PGE(2) release. All adenosine agonists, except for Cl-IB-MECA, significantly inhibited PGE(2) production. EMFs inhibited PGE(2) production in the absence of adenosine agonists and increased the effects of CHA, CGS 21680 and NECA. In ADA, the inhibition on PGE(2) release induced by CHA, CGS and NECA was stronger than in the absence of ADA and the EMF-inhibitory effect was lost. Changes in PGE(2) levels were associated to modification of COX-2 expression. CONCLUSIONS This study supports anti-inflammatory activities of A(1) and A(2A) adenosine receptors and EMFs in bovine SFs. EMF activity appears mediated by an EMF-induced up-regulation of A(2A) receptors. Biophysical and/or pharmacological modulation of adenosine pathways may play an important role to control joint inflammation.
Collapse
Affiliation(s)
- M De Mattei
- Department of Morphology and Embryology, University of Ferrara, Ferrara, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Varani K, De Mattei M, Vincenzi F, Gessi S, Merighi S, Pellati A, Ongaro A, Caruso A, Cadossi R, Borea PA. Characterization of adenosine receptors in bovine chondrocytes and fibroblast-like synoviocytes exposed to low frequency low energy pulsed electromagnetic fields. Osteoarthritis Cartilage 2008; 16:292-304. [PMID: 17698373 DOI: 10.1016/j.joca.2007.07.004] [Citation(s) in RCA: 87] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2007] [Accepted: 07/03/2007] [Indexed: 02/02/2023]
Abstract
OBJECTIVE The present study describes the presence and binding parameters of the A1, A2A, A2B and A3 adenosine receptors in bovine chondrocytes and fibroblast-like synoviocytes. The effect of low frequency low energy pulsed electromagnetic fields (PEMFs) on the adenosine receptor affinity and density was studied. METHODS Saturation, competition binding experiments and Western blotting assays in the absence and in the presence of PEMFs on the adenosine receptors in bovine chondrocytes or fibroblast-like synoviocytes were performed. Thermodynamic analysis of the A2A or A3 binding was studied to investigate the forces driving drug-receptor coupling. In the adenylyl cyclase and proliferation assays the potency of typical high-affinity A2A or A3 agonists in the absence and in the presence of PEMFs was evaluated. RESULTS Bovine chondrocytes and fibroblast-like synoviocytes expressed all adenosine receptors. PEMFs evoked an up-regulation of A2A and A3 receptors and thermodynamic parameters indicate that adenosine binding is enthalpy and entropy driven. In PEMF-treated cells the potency of typical A2A or A3 agonists on cyclic AMP assays was significantly increased when compared with the untreated cells. PEMFs potentiated the effect of A2A or A3 agonists on cell proliferation in both cell types. CONCLUSIONS PEMFs mediate an up-regulation of A2A and A3 receptors related to an increase of their functional activities in bovine chondrocytes and fibroblast-like synoviocytes. No differences are present in adenosine affinity and in the drug-receptor interactions. Our data could be used as a trigger to future studies addressed to PEMFs and adenosine therapeutic intervention in inflammatory joint diseases.
Collapse
Affiliation(s)
- K Varani
- Department of Clinical and Experimental Medicine, University of Ferrara, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Zorzi C, Dall'Oca C, Cadossi R, Setti S. Effects of pulsed electromagnetic fields on patients' recovery after arthroscopic surgery: prospective, randomized and double-blind study. Knee Surg Sports Traumatol Arthrosc 2007; 15:830-4. [PMID: 17333120 DOI: 10.1007/s00167-007-0298-8] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/18/2006] [Accepted: 01/22/2007] [Indexed: 11/27/2022]
Abstract
Severe joint inflammation following trauma, arthroscopic surgery or infection can damage articular cartilage, thus every effort should be made to protect cartilage from the catabolic effects of pro-inflammatory cytokines and stimulate cartilage anabolic activities. Previous pre-clinical studies have shown that pulsed electromagnetic fields (PEMFs) can protect articular cartilage from the catabolic effects of pro-inflammatory cytokines, and prevent its degeneration, finally resulting in chondroprotection. These findings provide the rational to support the study of the effect of PEMFs in humans after arthroscopic surgery. The purpose of this pilot, randomized, prospective and double-blind study was to evaluate the effects of PEMFs in patients undergoing arthroscopic treatment of knee cartilage. Patients with knee pain were recruited and treated by arthroscopy with chondroabrasion and/or perforations and/or radiofrequencies. They were randomized into two groups: a control group (magnetic field at 0.05 mT) and an active group (magnetic field of 1.5 mT). All patients were instructed to use PEMFs for 90 days, 6 h per day. The patients were evaluated by the Knee injury and Osteoarthritis Outcome Score (KOOS) test before arthroscopy, and after 45 and 90 days. The use of non-steroidal anti-inflammatory drugs (NSAIDs) to control pain was also recorded. Patients were interviewed for the long-term outcome 3 years after arthroscopic surgery. Thirty-one patients completed the treatment. KOOS values at 45 and 90 days were higher in the active group and the difference was significant at 90 days (P < 0.05). The percentage of patients who used NSAIDs was 26% in the active group and 75% in the control group (P = 0.015). At 3 years follow-up, the number of patients who completely recovered was higher in the active group compared to the control group (P < 0.05). Treatment with I-ONE aided patient recovery after arthroscopic surgery, reduced the use of NSAIDs, and also had a positive long-term effect.
Collapse
Affiliation(s)
- C Zorzi
- "Sacro Cuore Don Calabria" Hospital, Via don A. Sempreboni 5, 37024 Negrar (Vr), Italy
| | | | | | | |
Collapse
|
13
|
Giardino R, Fini M, Bonazzi V, Cadossi R, Nicolini A, Carpi A. Electrochemotherapy a novel approach to the treatment of metastatic nodules on the skin and subcutaneous tissues. Biomed Pharmacother 2006; 60:458-62. [PMID: 16930935 DOI: 10.1016/j.biopha.2006.07.016] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Electrochemotherapy (ECT) is a new treatment for metastatic nodules of solid tumors on the skin or subcutaneous tissue. ECT is a combination of a physical effect, cell membrane poration, and cytotoxic drug administration. Cell membrane poration is achieved by applying short intense electric filed pulses. Pore formation on the cell membrane allows low permeant drugs like bleomycin or cisplatin to enter the cell and thus locally increase their toxicity: up to 10.000 times for bleomycin and 80 times for cisplatin. ECT has been investigated in a multicenter study European Standard Operating Procedures for Electrochemotherapy (ESOPE) that demonstrates how by ECT over 80% of the cutaneous or subcutaneous metastatic nodules can be healed, thus confirming the results of previous studies. ECT efficacy is independent of tumor histology. The experience gathered in the ESOPE study allowed to prepare standard operating procedures that are key to the dissemination of the technology. ECT is safe effective, the treatment is completed in one session usually on an out-patient basis with minimum side-effects. ECT is cost-effective and, although palliative, it ameliorates patients' quality of life. ECT is the treatment of choice for tumors refractory to conventional treatment, can be used in form of cytoreductive therapy before conventional treatment for organ sparing and functions saving, finally can be adopted to treat hemorrhagic or painful nodules, it can be applied in previously irradiated areas.
Collapse
Affiliation(s)
- R Giardino
- Department of Experimental Surgery, Codivilla-Putti Research Insitute, Rizzoli Institute of Orthopaedics Via di Barbiano, Bologna, Italy.
| | | | | | | | | | | |
Collapse
|
14
|
Fini M, Giavaresi G, Giardino R, Cavani F, Cadossi R. Histomorphometric and mechanical analysis of the hydroxyapatite-bone interface after electromagnetic stimulation: an experimental study in rabbits. ACTA ACUST UNITED AC 2006; 88:123-8. [PMID: 16365135 DOI: 10.1302/0301-620x.88b1.16496] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
We investigated the effect of stimulation with a pulsed electromagnetic field on the osseointegration of hydroxyapatite in cortical bone in rabbits. Implants were inserted into femoral cortical bone and were stimulated for six hours per day for three weeks. Electromagnetic stimulation improved osseointegration of hydroxyapatite compared with animals which did not receive this treatment in terms of direct contact with the bone, the maturity of the bone and mechanical fixation. The highest values of maximum push-out force (F(max)) and ultimate shear strength (sigma(u)) were observed in the treated group and differed significantly from those of the control group at three weeks (F(max); p < 0.0001; sigma(u), p < 0.0005).
Collapse
Affiliation(s)
- M Fini
- Experimental Surgery Laboratory, Research Institute Codivilla-Putti, Rizzoli Orthopaedic Institute, Via di Barbiano 1/10, 40136 Bologna, Italy.
| | | | | | | | | |
Collapse
|
15
|
Wüster C, de Terlizzi F, Becker S, Cadossi M, Cadossi R, Müller R. Usefulness of quantitative ultrasound in evaluating structural and mechanical properties of bone: Comparison of ultrasound, dual-energy X-ray absorptiometry, micro-computed tomography, and mechanical testing of human phalanges in vitro. Technol Health Care 2005. [DOI: 10.3233/thc-2005-13605] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- C. Wüster
- Department of Endocrinology, University of Heidelberg & Clinic for Endocrinology, Bahnhofplatz 2, D-55116 Mainz, Germany
| | | | - S. Becker
- Department of Endocrinology, University of Heidelberg & Clinic for Endocrinology, Bahnhofplatz 2, D-55116 Mainz, Germany
| | - M. Cadossi
- IGEA Biophysics Laboratory, Carpi (MO), Italy
| | - R. Cadossi
- IGEA Biophysics Laboratory, Carpi (MO), Italy
| | - R. Müller
- Orthopedic Biomechanics Laboratory, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, USA
| |
Collapse
|
16
|
Wüster C, de Terlizzi F, Becker S, Cadossi M, Cadossi R, Müller R. Usefulness of quantitative ultrasound in evaluating structural and mechanical properties of bone: comparison of ultrasound, dual-energy X-ray absorptiometry, micro-computed tomography, and mechanical testing of human phalanges in vitro. Technol Health Care 2005; 13:497-510. [PMID: 16340093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
INTRODUCTION Ultrasound studies evaluating bone tissue generally concentrate on two parameters--velocity and attenuation. This study aimed to determine whether ultrasound signal analysis techniques could provide additional information on the structural and mechanical characteristics of bone. MATERIALS AND METHODS In vitro measurements were made on 26 left index fingers from human cadavers. Ultrasound measurements at the distal metaphysis and epiphysis; dual-energy X-ray absorptiometry of the whole phalanx; micro-computed tomography at the distal quarter of the phalanx (that is, the distal epiphysis and metaphysis), and mechanical three-point bending tests were performed. Univariate and multivariate linear regression techniques were used to analyze the results. RESULTS The ultrasound parameters, speed of sound and ultrasound peak amplitude correlated significantly with the three micro-computed tomography measures used to describe the characteristics of mineralized material (r=0.69-0.79, p<0.05). Low frequency ultrasound correlated significantly with micro-computed tomography parameters describing inter-trabecular or marrow spaces (r=0.68-0.78, p<0.05). Comparison of ultrasound parameters with geometric characteristics showed that while speed of sound and ultrasound peak amplitude were related to the cortical area, moment of inertia, and mechanical load (r=0.57-0.83, p< 0.05), the amplitude of the fastest part of the ultrasound signal and full width at 80% maximum of the low frequency peak were related to the relative area of the medullary canal (r=0.40-0.43, p<0.05). DISCUSSION Quantitative ultrasound may provide information on structural, material and mechanical characteristics of bone to the same extent and even better than DXA Bone Mineral Density. These results have been obtained by a complete and exhaustive use of QUS technology in situ but under clinical conditions. The ultrasound parameters, correctly used and combined, seem to be effective tools for investigating bone tissue.
Collapse
Affiliation(s)
- C Wüster
- Department of Endocrinology, University of Heidelberg & Clinic for Endocrinology, Bahnhofplatz 2, D-55116 Mainz, Germany
| | | | | | | | | | | |
Collapse
|
17
|
Barkmann R, Rohrschneider W, Vierling M, Tröger J, de TF, Cadossi R, Heller M, Glüer CC. German pediatric reference data for quantitative transverse transmission ultrasound of finger phalanges. Osteoporos Int 2002; 13:55-61. [PMID: 11878455 DOI: 10.1007/s198-002-8338-8] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Quantitative ultrasound (QUS) of the finger phalanges is a useful tool in the assessment of disease- or age-related deterioration of bone. For studying the impact of juvenile diseases or growth disorders affecting the skeleton, a reference database for QUS parameters is needed. The aim of this study was to establish a calibrated reference database of parameters of transverse ultrasound transmission through juvenile finger phalanges. A total of 1328 children (650 females, 678 males; ages 3-17 years) were measured in Heidelberg and Kiel in order to establish a German reference database. Highly significant gender-specific correlations (p<0.0001) were found between the QUS parameters amplitude-dependent speed of sound (AD-SoS) and bone transmission time (BTT) versus age, body height and body mass index (BMI). For AD-SoS the correlation coefficients were R2 = 0.64 against age in males and R2 = 0.73 in females, R2 = 0.60 against body height in males and R2 = 0.68 in females, and R2 = 0.19 against BMI in males and R2 = 0.23 in females. For BTT the correlation coefficients were R2 = 0.74 against age in males and R2 = 0.79 in females, R2 = 0.75 against body height in males and R2 = 0.77 in females, and R2 = 0.32 against BMI in males and R2 = 0.35 in females. Age and height were the strongest determinants of QUS results. Gender-specific differences were observed in AD-SoS (significant for ages 11-14 years and for 150-170 cm body height) and in BTT (significant for ages 7 and 11-17 years and for 160-170 cm body height). Tables of QUS parameters versus age and height can serve as a basis for the evaluation of the impact of skeletal diseases or growth disorders on phalangeal QUS. Depending on the type of disease or growth disorder, measurement results can be compared with age- or height- specific reference data. In this way a simple and radiation-free assessment of juvenile skeletal disorders using quantitative ultrasound might be possible in the future.
Collapse
Affiliation(s)
- R Barkmann
- Medizinische Physik, Klinik für Diagnostische Radiologie, Universitätsklinikum Kiel, Germany
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Hentz VR, Stephanides M, Boraldi A, Tessari R, Isani R, Cadossi R, Biscione R, Massari L, Traina GC. Surgeon-patient barrier efficiency monitored with an electronic device in three surgical settings. World J Surg 2001; 25:1101-8. [PMID: 11571942 DOI: 10.1007/bf03215854] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Blood-borne viral pathogens are an occupational threat to health care workers (HCWs), particularly those in the operating room. A major risk is posed by accidental penetrating injury, but skin contamination with body fluids from an infected patient, with prolonged intimate cutaneous contact, is a frequent occurrence during surgery, carrying further risk of transdermal infection. We have monitored barrier failure in three surgical settings (microsurgery, orthopedic surgery, general surgery) by means of an electronic surveillance device. A total of 111 surgical procedures were monitored: 67 microsurgeries, 22 orthopedic surgeries, and 22 general surgeries. Of the 278 electronic alarms signaling barrier failure, 44 (15.8%) were associated with glove perforation, 39 of which (88.6%) were not perceived by the operator. In 16 of those, the skin was visibly stained with the patient's blood. Altogether, 76 of the alarms (27.3%) were consequent to contacts caused by soaked gowns/sleeves, and 121 (43.5%) were attributed to hydration of latex porosities; 37 alarms (13.4%) were unexplained false positives. On only one occasion did a surgeon observe blood stains on his hands without a previous alarm; this event was classified as a device failure due to incorrect wiring. Double-gloving offered satisfactory protection against skin contamination during microsurgery but not during orthopedic surgery. The data presented here indicate that electronic monitoring of the surgical barrier enables prompt detection of barrier failure, especially at the level of the gloves, thereby limiting skin contamination with patients' body fluids during surgery.
Collapse
Affiliation(s)
- V R Hentz
- Department of Surgery, Division of Hand Surgery, Stanford University Medical Center, 300 Pasteur Drive, M121, Stanford, California 94305-5119, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Cadossi R, de Terlizzi F, Canè V, Fini M, Wüster C. Assessment of bone architecture with ultrasonometry: experimental and clinical experience. Horm Res 2001; 54 Suppl 1:9-18. [PMID: 11146374 DOI: 10.1159/000063442] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Over the last decade, ultrasound technology has been introduced as a method of analysing bone tissue in clinical practice, and several studies have compared various ultrasound devices with dual-energy X-ray absorptiometry (DXA). Unlike DXA, the ultrasound technique is not limited to the measurement of bone density - it also has the potential to provide information on the mechanical and architectural characteristics of bone. The first generation of ultrasound devices used the speed of sound and attenuation of the ultrasound signal to obtain information on bone mineral content. Second generation ultrasound devices, which analyse the ultrasound signal received, permit the study of bone structure and elasticity, in addition to its mineral content, in both experimental studies and clinical practice. This is accomplished by signal processing analysis, the study of backscattering and the application of Biot's theory. This approach to the study of bone tissue represents the future for the development of ultrasound technology for use in clinical practice.
Collapse
Affiliation(s)
- R Cadossi
- Laboratory of Clinical Biophysics, IGEA, Carpi, Italy.
| | | | | | | | | |
Collapse
|
20
|
Baroncelli GI, Federico G, Bertelloni S, de Terlizzi F, Cadossi R, Saggese G. Bone quality assessment by quantitative ultrasound of proximal phalanxes of the hand in healthy subjects aged 3--21 years. Pediatr Res 2001; 49:713-8. [PMID: 11328957 DOI: 10.1203/00006450-200105000-00017] [Citation(s) in RCA: 82] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Bone quality by quantitative ultrasound was assessed in 1083 (587 males) healthy white subjects aged 3--21 y. Amplitude-dependent speed of sound (AD-SoS) through the distal end of the first phalanx diaphysis of the last four fingers of the hand was measured by an ultrasound device (DBM Sonic 1200, IGEA, Carpi, Italy). Mean AD-SoS values increased progressively from 3 to 21 y (males, 1845.9--2119.1 m/s, p < 0.0001; females, 1842.3--2098.8 m/s, p < 0.0001). They did not differ (p = NS) between sexes up to age 11, but females showed higher (p < 0.05 - p < 0.0001) AD-SoS values than males in age groups 12, 13, and 14 y. There was no difference (p = NS) of AD-SoS values between sexes in pubertal stages 1, 2, and 5, but females had higher mean AD-SoS values than males in stages 3 (p < 0.01) and 4 (p < 0.001). Independent predictors of AD-SoS were weight, body mass index, pubertal stage, and mean width of fingers in males, and age, pubertal stage, and mean width of fingers in females (p < 0.01 - p < 0.0001). However, 7.8% in males and 3.6% in females of the increment of AD-SoS values can be related to the finger anatomy alone. AD-SoS values probably reflect the architectural organization of growing bone or changes in bone elasticity. Increased bone density and size may be additional factors influencing AD-SOS: Measurement of AD-SoS at the hand phalanxes may be a simple, noninvasive, and radiation-free technique to assess bone quality in children.
Collapse
Affiliation(s)
- G I Baroncelli
- Endocrine Unit, Division of Pediatrics, Department of Reproductive Medicine and Pediatrics, University of Pisa, Pisa, IT-56125, Italy.
| | | | | | | | | | | |
Collapse
|
21
|
Hentz RV, Traina GC, Cadossi R, Zucchini P, Muglia MA, Giordani M. The protective efficacy of surgical latex gloves against the risk of skin contamination: how well are the operators protected? J Mater Sci Mater Med 2000; 11:825-832. [PMID: 15348067 DOI: 10.1023/a:1008913814999] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Latex gloves are used by surgical staff to avoid exposure to patient body fluids, thus reducing the risk of contracting bloodborne viral diseases, such as hepatitis C and HIV. We studied the efficacy of the surgical barrier provided by latex gloves, before and after use in the operating theater. The electrical conductivity, insulation and mechanical resistance of glove latex were investigated, using routine supplies of surgical gloves. Latex structure was assessed by scanning electron microscopy and by mercury intrusion porosimetry. Latex is subject to hydration, a phenomenon associated in the laboratory with the loss of its electrical insulation properties. Such glove latex properties were found to be highly variable, with latex hydration times varying between 2 and more than 30 min. Rapidly hydrating gloves showed increased permeability to methylene blue, associated with higher levels of porosity. Thirty min of surgical use was associated with measurable hydration of glove latex and a statistically significant loss of electrical and mechanical resistance, with rupture load decreasing by 24%. Electronic control of the insulation properties of gloves during surgery permits early detection of hydration, and allows prompt correction by glove change, before the gloves lose their electrical and mechanical competence.
Collapse
Affiliation(s)
- R V Hentz
- Hand Surgery, Stanford University School of Medicine, Stanford, USA
| | | | | | | | | | | |
Collapse
|
22
|
Abstract
Ultrasound (US) waves are mechanical vibrations that are applied to a material--bone tissue--in order to study its properties, that is, density, elasticity, and structure. In this study we evaluated in which way density and elasticity of the spongy bone influenced the transmission of 1.25 MHz US pulses. Twelve cylindrical specimens (diameter, 8 mm; height, 5 mm) excised from phalanxes of pig were decalcified with 0.5 M EDTA for different times (0, 2, and 5 days). During these periods, the samples underwent the following investigations: US transmission, density, and elasticity measurements. To assess the homogeneity of decalcification, the cross-sections of some samples were microradiographed. A detailed analysis of the US signal received was performed using velocity, Fourier analysis, and some parameters typical of signal processing technique. A good correlation was found between US velocity and density (r2 = 0.70); a lower correlation was found between velocity and elasticity (r2 = 0.59). If density and elasticity are considered simultaneously, the correlation with the US velocity improves significantly (r2 = 0.84). Fourier analysis enabled us to observe a shift of the main frequency toward lower values as the decalcification process advanced. We also observed that in the regressions weighted for density, US velocity correlated poorly with elasticity (r2 = 0.16), whereas signal processing parameters maintain a good correlation with elasticity (ultrasound peak amplitude [UPA], r2 = 0.48; slope, r2 = 0.62). In this study, it has been observed that when using a signal processing technique to analyze US pulses, it is possible to identify some parameters that are related in different ways to density and to elastic properties of bone. Our results show the potentiality of US technique to separate information on bone density and elasticity that X-ray-based densitometric methods do not provide.
Collapse
Affiliation(s)
- F De Terlizzi
- IGEA Laboratory of Clinical Biophysics, Carpi Mo, Italy
| | | | | | | | | |
Collapse
|
23
|
Mauloni M, Rovati LC, Cadossi R, de Terlizzi F, Ventura V, de Aloysio D. Monitoring bone effect of transdermal hormone replacement therapy by ultrasound investigation at the phalanx: a four-year follow-up study. Menopause 2000; 7:402-12. [PMID: 11127763 DOI: 10.1097/00042192-200011000-00006] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE A controlled 4-year follow-up study was conducted on a population composed of 112 healthy early postmenopausal women to evaluate the ability of ultrasound technology in detecting the effects of hormone replacement therapy (HRT) on bone. At the end of the study, 47 untreated and 25 treated women had been evaluated. Cyclic sequential estrogen/progestogen therapy, 50 microg/day of transdermal 17beta-estradiol (Rotta Research Laboratorium) plus 5 mg/day of medrogestone (Wyeth-Ayerst) was used. DESIGN Ultrasound transmission through the distal metaphysis of hand phalanxes was measured by DBM Sonic. Beside amplitude-dependent speed of sound (AD-SoS), three new parameters could be calculated: pure speed of sound (pSOS), bone transmission time (BTT), and ultrasound bone profile index (UBPI). Ultrasound measurements were taken at baseline and after 1, 2, and 4 years. RESULTS Among untreated women a significant decrease of all ultrasound parameters was observed at follow-up measurements. In the HRT-treated group we observed a significant increase of AD-SoS, pSoS, and BTT. We qualified as "responders" women in the treated group for whom AD-SoS, pSoS, and BTT increased by more than 2.77 times the coefficient of variation of the measurement, i.e., 95% variability. Women in the treated group were identified as responders at 4 years of follow-up by AD-SoS (56%), pSOS (56%), and BTT (60%). Ultrasound bone profile index declined in both groups, although to a lower extent among HRT-treated subjects. CONCLUSIONS The 4-year data confirm the results obtained at 1 and 2 years of follow-up. This study demonstrates that bone tissue investigation by ultrasound at the phalanx can be used to monitor the effect of HRT, and thus it should be considered a potential technology for the management of menopause by gynecologists.
Collapse
Affiliation(s)
- M Mauloni
- Menopause Clinic, Department of Obstetrics and Gynaecology, University of Bologna, Italy
| | | | | | | | | | | |
Collapse
|
24
|
Wüster C, Albanese C, De Aloysio D, Duboeuf F, Gambacciani M, Gonnelli S, Glüer CC, Hans D, Joly J, Reginster JY, De Terlizzi F, Cadossi R. Phalangeal osteosonogrammetry study: age-related changes, diagnostic sensitivity, and discrimination power. The Phalangeal Osteosonogrammetry Study Group. J Bone Miner Res 2000; 15:1603-14. [PMID: 10934660 DOI: 10.1359/jbmr.2000.15.8.1603] [Citation(s) in RCA: 173] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Phalangeal osteosonogrammetry was introduced as a method for bone tissue investigation in 1992. It is based on the measure of the velocity of ultrasound (amplitude-dependent speed of sound [AD-SoS]) and on the interpretation of the characteristics of the ultrasound signal. In this study we have collected a database of 10,115 subjects to evaluate the performance of AD-SoS and to develop a parameter that is able to quantify the signal characteristics: ultrasound bone profile index (UBPI). The database only includes females of which 4.5% had documented vertebral osteoporotic fractures, 16% lumbar spine dual X-ray absorptiometry (DXA), and 6% hip DXA. The analysis of the ultrasound signal has shown that with aging the UBPI, first wave amplitude (FWA), and signal dynamics (SDy) follow a trend that is different from the one observed for AD-SoS; that is, there is no increase during childhood. In the whole population, the risk of fracture per SD decrease for AD-SOS was odds ratio (OR) 1.71 (CI, 1.58-1.84). The AD-SoS in fractured subjects was significantly lower than in a group of age-matched nonfractured subjects (p < 0.0001). In a small cohort of hip-fractured patients UBPI proved to be lower than in a control age-matched group (p < 0.0001). When the World Health Organization (WHO) working group criteria were applied to this population to identify the T score value for osteoporosis, for AD-SoS we found a T score of -3.2 and for UBPI we found a T score of -3.14. Sixty-six percent of vertebral fractures were below the AD-SoS -3.2 T score and 62% were below UBPI -3.14. We observed the highest incidence of fractures (63.6%) among subjects with AD-SoS who had both DXA T score values below the threshold. We conclude from this study that ultrasound investigation at the hand phalanges is a valid methodology for osteoporosis assessment. It has been possible to quantify signal changes by means of UBPI, a parameter that will improve the possibility of investigating bone structure.
Collapse
Affiliation(s)
- C Wüster
- Department of Internal Medicine I, Endocrinology and Metabolism, University of Heidelberg, Germany
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
|
26
|
Giavaresi G, De Terlizzi F, Gnudi S, Cadossi R, Aldini NN, Fini M, Rocca M, Ripamonti C, Brandi ML, Giardino R. Discriminant capacity of quantitative ultrasound versus dual X-ray absorptiometry to determine cancellous bone loss in ovariectomized rats. Bone 2000; 26:297-303. [PMID: 10710005 DOI: 10.1016/s8756-3282(99)00267-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
The capacity of dual x-ray absorptiometry and quantitative ultrasound to discriminate bone loss and to predict the mechanical and microarchitectural properties of cancellous bone in an animal model of osteopenia was evaluated. Thirty-five female Sprague-Dawley rats (10 months old) were randomized into three groups: baseline group, 10 rats killed at the beginning of the study; ovx group, 15 rats ovariectomized; and sham group, 10 rats sham operated. At the beginning and end of the study, all the animals underwent osteosonography to record the proximal tail (C3 vertebra) bone speed of sound. Sixteen weeks after surgery, the animals were euthanized and the L5-6 lumbar vertebrae of each rat were excised for densitometric, biomechanical (compression test), and histomorphometric studies. Significant differences were found among the groups for final speed of sound (p = 0.01). The L5 bone mineral density of the ovx group decreased by 12.1% (p = 0.049) and 12.6% (p = 0.035) compared, respectively, with baseline and sham groups. The biomechanical parameters of the ovx group decreased by 15-47% compared with the other groups, showing significant differences between the ovx and sham groups both for maximal stress (p = 0.026) and elastic modulus (p = 0.013). Histomorphometric parameters of the ovx group showed significant decreases in comparison with other groups. Logistic regression analysis showed that dual X-ray absorptiometry and quantitative ultrasound discriminate ovariectomized and healthy rats with a similar capacity, classifying correctly all rats used in the model in a range of 61-70%. This similar capacity seems to derive from two different capacities to detect bone changes. Dual X-ray absorptiometry, depending on bone mineralization and density, is able to detect modifications in bone stiffness and strength, confirmed also by the correlation with biomechanical data. On the contrary, quantitative ultrasound seems to depend more on cancellous bone microarchitecural changes because it is correlated to histomorphometric parameters.
Collapse
Affiliation(s)
- G Giavaresi
- Department of Experimental Surgery, Istituti Ortopedici Rizzoli, Bologna, Italy.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Pezzetti F, De Mattei M, Caruso A, Cadossi R, Zucchini P, Carinci F, Traina GC, Sollazzo V. Effects of pulsed electromagnetic fields on human chondrocytes: an in vitro study. Calcif Tissue Int 1999; 65:396-401. [PMID: 10541767 DOI: 10.1007/s002239900720] [Citation(s) in RCA: 83] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
(3)H-thymidine incorporation was studied in cultured human nasal and articular chondrocytes exposed to low-energy, low-frequency pulsed electromagnetic fields (PEMFs) (75 Hz, 2.3 mT). The reverse transcriptase polymerase chain reaction (RT-PCR) analysis shows that human secondary chondrocytes derived from both nasal and articular cartilage express collagen type II mRNA, which is a specific marker of the chondrocyte phenotype. In a preliminary series of experiments, cells were exposed to PEMF for different time periods ranging from 6 to 30 hours (time-course), in medium supplemented with 10% or 0.5% fetal calf serum (FCS) and in serum-free medium. The ratios between the (3)H-thymidine incorporation in PEMFs and control cultures show an increase of the cell proliferation in cultures exposed to PEMFs when serum is present in the culture medium, whereas no effect was observed in serum-free conditions. The increase in DNA synthesis, induced by PEMFs, was then evaluated only at the times of maximum induction and the results were analyzed by the three-factor analysis of variance (ANOVA). The data presented in this study show that even if (3)H-thymidine incorporation is higher in nasal than in articular chondrocytes, PEMF induce an increase in the proliferation of both cell types. Moreover, the concentration of FCS in the culture medium greatly influences the proliferative response of human chondrocytes to the PEMF exposure. Though normal human osteoblast cells increase their proliferation when exposed to PEMFs if only 10% FCS is present in the medium, human chondrocytes are able to increase their cell proliferation when exposed to PEMFs in the presence of both 0.5% and 10% of FCS in the medium. The results obtained may help to explain the basic mechanisms of PEMF stimulation of fracture healing.
Collapse
Affiliation(s)
- F Pezzetti
- Dipartimento di Morfologia ed Embriologia, Università di Ferrara, via Fossato di Mortara 64, 44100 Ferrara, Italy
| | | | | | | | | | | | | | | |
Collapse
|
28
|
Albertini A, Zucchini P, Noera G, Cadossi R, Pace Napoleone C, Pierangeli A. Protective effect of low frequency low energy pulsing electromagnetic fields on acute experimental myocardial infarcts in rats. Bioelectromagnetics 1999; 20:372-7. [PMID: 10453065 DOI: 10.1002/(sici)1521-186x(199909)20:6<372::aid-bem6>3.0.co;2-l] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
This series of experiments assesses the effect of exposure to low-frequency pulsing electromagnetic fields (PEMFs) in 340 rats with acute experimental myocardial infarcts. The left anterior descending artery was ligated with suture thread, and the rats underwent total body exposure to PEMFs until they were killed. Twenty-four hours after surgery, the necrotic area was evaluated by staining with triphenyltetrazolium chloride. A significant reduction of the necrotic area was observed in the animals exposed to PEMFs compared with the nonexposed controls. Exposure for up to 6 days does not appear to affect the area of necrosis, although in exposed animals an increase of vascular invasion of the necrotic area is observed: 24.3 % as against 11.3 % in controls. No effect on the necrotic area size from exposure was found when the left anterior descending artery was occluded for 60 min, followed by reperfusion. The results reported show that exposure to PEMFs is able to limit the area of necrosis after an acute ischemic injury caused by permanent ligation of the left anterior descending artery. These data are in agreement with the protective effect of PEMFs observed on acute ischemia in skin free flaps in rats and in cerebral infarcts in rabbits.
Collapse
Affiliation(s)
- A Albertini
- Hospital S.M. Misericordia of Udine, Udine, Italy
| | | | | | | | | | | |
Collapse
|
29
|
Soballa T, Wüster C, Schlegel J, Cadossi R, Isani R, Battista S, Heilmann P, Ziegler R. Ultrasound transmission speed and ultrasound bone profile score (UBPS) of the phalanges in normal women and women with osteoporosis. Horm Metab Res 1998; 30:536-41. [PMID: 9761387 DOI: 10.1055/s-2007-978928] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
The distal metaphysis of the first phalanx of the fingers II-V is, like the vertebral body, a useful site for the measurement of mineralisation and structure of the bone because of the simultaneous presence of compact and trabecular bone. With an ultrasound device (DBM sonic 1200, IGEA, Italy), we measured the adSOS (the amplitude dependent speed of sound) and the UBPS (ultrasound bone profile score), a score which is calculated from the graphic traces of the receiving probe with an expert system which uses fuzzy-logic at phalanges II-IV, as well as bone mineral density (BMD) at lumbar spine using dual X-ray absorptiometry (DXA). Precision of the measurements was as follows: adSOS: short-time-CV% = 0.576, long-time-CV% = 1.1, SCV% = 5.9, RMSSD% = 1.825. UBPS: short-time CV% = 5.95. There was no correlation between adSOS or UBPS and lumbar BMD (DXA). There was a significant positive correlation between adSOS and UBPS, r = 0.804 (p<0.00001). The validity of adSOS and UBPS was examined in 25 young and healthy women (mean age: 33.4 year), 15 postmenopausal healthy women (mean age: 58.5 years), 17 women with osteopenia, (mean age: 52.4 years), as defined by a t-score between -1 to -2.5 SD as lumbar BMD (DXA), and 20 women with osteoporosis and vertebral fractures (mean age: 61.4 years). We compared the healthy postmenopausal women and the women with osteoporotic vertebral fractures, the z-score of the adSOS was below minus 1.5 SD and UBPS was below 40, sensitivity was 0.7 for adSOS, and 0.85 for UBPS, with a specificity 0.97 for adSOS, and of 0.93 for UBPS; positive predictive value: adSOS: 0.93, UBPS: 0.85. AdSOS declined with age (r= 0.694, p=0.021); the UBPS was not age dependent (r=-0.15, p = n.s.). The ROC-curve shows a value of 0.96 for adSOS and 0.94 for UBPS. AdSOS and UBPS could discriminate well between the healthy controls and the women with osteopenia or vertebral fractures (p<0.00001). These results show that adSOS and UBPS are precise parameters to be measured at the phalanges. The detection level of pathological changes in osteoporosis are similar between adSOS and lumbar BMD (DXA) and improved by using the UBPS. This might be explained by the influence of structural changes in bone on UBPS, rather than change in bone mineral alone. Prospective studies have to clarify the role of adSOS and UBPS in fracture prediction.
Collapse
Affiliation(s)
- T Soballa
- Dept. of Internal Medicine I, Endocrinology and Metabolism, University of Heidelberg, Germany
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Abstract
BACKGROUND The distal metaphysis of the first phalanx of the fingers II to V is, like the vertebral body, a useful site for the measurement of mineralisation and structure of the bone, because of the simultaneous presence of compact and trabecular bone. METHOD With an osteosonographic device (DBM sonic 1200, IGEA, Italy) we measured in 38 young and healthy men, 14 elderly and healthy men, 18 men with osteopenia, 8 men with osteoporosis and vertebral fractures and 10 men with long-standing cortisone medication, the adSOS (amplitude-dependent speed of sound) and the UBPS (ultrasound bone profile score) at the phalanges, as well as bone mineral density (BMD) at lumbar spine using dual-X-ray absorptiometry (DXA). RESULTS There was no correlation between adSOS or UBPS and lumbar BMD (DXA). There was a significant positive correlation between adSOS and UBPS, r = 0.826 (p < 0.00001). AdSOS declined with age (r = 0.694, p = 0.021); the UBPS was not age-dependent (r = -0.15, p = n.s.), as expected. AdSOS and UBPS could discriminate significantly between the young and healthy controls and the men with osteopenia/vertebral fractures or oral steroids (p < 0.00001). The DXA could be significantly discriminate all healthy controls from the patients with osteopenia or vertebral fractures. It could not significantly discriminate the healthy controls from the patients taking oral glucoconticoids. Only the UBPS could significantly discriminate this group from the healthy controls. CONCLUSION These results show, that adSOS and UBPS are precise parameters to be measured at the phalanges. The detection level of pathological changes in osteoporosis are similar between adSOS and lumbar BMD (DXA) and improved by using UBPS. This might be explained by the influence of structural changes in bone on UBPS, rather than changes in bone mineral alone. Prospective studies have to clarify the role of adSOS and UBPS in fracture prediction.
Collapse
Affiliation(s)
- T Soballa
- Innere Medizin I, Endokrinologie und Stoffwechsel, Krehl-Klinik, Heidelberg
| | | | | | | | | | | | | |
Collapse
|
31
|
de Aloysio D, Rovati LC, Cadossi R, Paltrinieri F, Mauloni M, Mura M, Penacchioni P, Ventura V. Bone effects of transdermal hormone replacement therapy in postmenopausal women as evaluated by means of ultrasound: an open one-year prospective study. Maturitas 1997; 27:61-8. [PMID: 9158079 DOI: 10.1016/s0378-5122(97)01120-1] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVES To evaluate the effectiveness of transdermal oestrogen replacement therapy plus medrogestone (HRT) in postmenopausal bone loss prevention by means of US. METHODS We enrolled 112 healthy postmenopausal women in an open, prospective study. These women, after a gynaecological evaluation and an US assessment of the skeletal status, were advised to take cyclic sequential oestrogen/progestagen therapy: 50 microg/day of transdermal 17beta-oestradiol (Rotta Research Laboratorium) plus 5 mg/day of medrogestone, for 12 days per cycle (Wyeth-Ayerst). After 1 year we recalled these women: only 32 of them were taking HRT, while 49 had declined HRT without taking alternative therapies. The remaining women were excluded from the study as they were either unavailable for the check-up or they were taking prohibited therapies. We used DBM Sonic 1200 (Igea, Italy) to assess US parameter changes at phalanxes at enrollment and after 1 year. This device enabled us to evaluate US transmission velocity (AD-SoS) and US attenuation pattern (UBPS). In a previous study we had evaluated the intra- and inter-observer reproducibility of AD-SoS measurements (0.4 and 1.0% respectively). Using the same data we evaluated the intra- and inter-observer precision of UBPS. RESULTS The UBPS intra-operator reproducibilities were 5.3% and 6.1% (for the 1st and the 2nd operator, respectively), while inter-observer precision was 8.8%. Both AD-SoS and UBPS significantly decreased in the non-user group(-0.7%, P < 0.001 and -14.3%, P < 0.001 respectively). In the user group AD-SoS showed a significant increase (+0.7%, P < 0.01), while a slight but significant decrease was observed for UBPS (-2.8%, P < 0.05). CONCLUSIONS Our findings show that the effectiveness of transdermal HRT in slowing or even arresting postmenopausal bone loss can be monitored by quantitative US studies. The trend difference observed between AD-SoS and UBPS with and without therapy is at least partially explained by a different response to HRT with regard to bone density as well as structure.
Collapse
Affiliation(s)
- D de Aloysio
- Menopause Clinic, Department of Obstetrics and Gynaecology, University of Bologna, Italy
| | | | | | | | | | | | | | | |
Collapse
|
32
|
Mele R, Masci G, Ventura V, de Aloysio D, Bicocchi M, Cadossi R. Three-year longitudinal study with quantitative ultrasound at the hand phalanx in a female population. Osteoporos Int 1997; 7:550-7. [PMID: 9604051 DOI: 10.1007/bf02652561] [Citation(s) in RCA: 68] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
A longitudinal study was conducted to assess the value of quantitative ultrasound (QUS) measurement in predicting the risk of fracture and to evaluate how QUS parameters change with ageing and the climacteric. A group of 211 female subjects underwent assessment by QUS at the distal metaphysis of the first phalanx of the last four fingers of the hand on two occasions 3 years apart. The subjects were selected from outpatients attending the orthopaedic clinic, provided they were not affected by metabolic disease or under treatment with drugs known to interfere with bone metabolism. In vivo the coefficient of variation and the standardized coefficient of variation of the QUS device were respectively 0.5% and 3.5%. The correlation between the values of the amplitude-dependent speed of sound (AD-SoS) in the two measurements was r = 0.92. In 77.3% of the subjects during the observation period we recorded a reduction in AD-SoS. During the study 22 fractures were observed in peripheral sites, 8 of which were associated with 'low-energy trauma'. By multiple logistic regression analysis we found that the relative risk of fracture for a 1 SD reduction in AD-SoS was 1.5 (95% CI 1.1-1.7) (p < 0.03). The percentage of low-energy fractures significantly increased among those subjects with an AD-SoS value lower than 1850 m/s (T-score < -3.5) at the first examination (p <0.0001). QUS investigation proved to be especially sensitive to hormonal changes associated with the climacteric: we observed a mean decrease of 56 m/s in the AD-SoS for women who entered the menopause between the first and the second QUS test (average time since menopause 2 years), as against 10 m/s in subjects remaining premenopausal. In a group of 146 subjects with 'normal' Ad-SoS at the first examination, we observed a significant reduction in AD-SoS only after 40 years of age. This study demonstrates that measurement of the AD-SoS at the phalanx is reproducible, can be employed to assess the risk of fracture, and is able to detect age-related alterations in bone tissue.
Collapse
Affiliation(s)
- R Mele
- Department of Orthopaedic Surgery, Ospedale Civile, Pordenone, Italy
| | | | | | | | | | | |
Collapse
|
33
|
Abstract
Ultrasound (US) has been studied by several researchers to assess its possible use in screening for osteoporosis; among other sites the phalanxes have been proposed as a possible site for investigation with US. In the present experimental work we studied the morphostructural characteristics of the second phalanx of the pig; then, in vitro, we investigated the behaviour of an ultrasound signal at 1.25 MHz crossing the distal metaphysis of the second phalanx. In particular, we studied the effects of milling or drilling on US velocity, and on the energy and shape of the signal generated by the US at the receiving probe. We demonstrated that the US velocity decreases by an average of 496 m/s (-21%) when axial perforations are made in the central marrow. A decrease is also noted in the number of peaks, and the normalized energy of the US signal received falls on average by 11.3 mV microseconds (-84%). The characteristics of the signal at the receiving probe can be broadly reconstituted if, after extensive drilling, the bone cavity is filled with polymerized styrene resin. In contrast, if phalanx milling is performed to remove the outermost bone tissue, the normalized energy increases by 15.5 mV microseconds (+84%) and the velocity of US increases by 163 m/s (+7%). It was also noted that the complexity of the signal received (i.e. number of peaks) and the signal normalized energy depend on the integrity of the bone structures traversed. The results reported here provide useful indications for interpreting the findings of clinical investigations with US, most specifically those performed on the phalanx of the hand.
Collapse
Affiliation(s)
- R Cadossi
- Department of Medical, Oncological and Radiological Sciences, University of Modena, Italy
| | | |
Collapse
|
34
|
Capanna R, Donati D, Masetti C, Manfrini M, Panozzo A, Cadossi R, Campanacci M. Effect of electromagnetic fields on patients undergoing massive bone graft following bone tumor resection. A double blind study. Clin Orthop Relat Res 1994:213-21. [PMID: 8070199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
Massive bone allograft after tumor resection has been used for over 20 years. Many factors negatively influence the healing of the junction between the allograft and the host bone, resulting in a low healing rate and lengthy time to union. This study evaluated whether pulsing electromagnetic field stimulation could be advantageously used in these patients. A double blind prospective randomized study was designed. Eighty three host graft junctions in 47 patients were considered. The overall host graft junction healing rate was the same (67%) in both control and active stimulated patients. Although not statistically significant, a positive effect of pulsing electromagnetic fields was observed for those host graft junctions with a cortico-cortical contact between allograft and host bone. When adjuvant postoperative chemotherapy was not employed, a definite effect of pulsing electromagnetic field stimulation was observed: the healing time decreased from 9.4 months in the control group to 6.7 months in the active stimulated group (p < 0.001). This effect would have been lost if chemotherapy was employed. There was also no advantage in supplement with iliac crest autografts at the host graft junction site if chemotherapy was used. Factors that significantly influenced the host graft junction healing rate were: chemotherapy; type of allograft host bone contact; quality of host graft junction; and, in intercalary allografts, use of the osteosynthesis device. No difference was observed between control and active groups for patient survival or number of local or distal tumor recurrences.
Collapse
Affiliation(s)
- R Capanna
- Istituto Ortopedico Rizzoli, Clinica Ortopedica I, Università di Bologna, Italy
| | | | | | | | | | | | | |
Collapse
|
35
|
Lusenti T, Cadossi R, Franco V, Soliani F, Rustichelli R, Borgatti P. [Ultrasound evaluation of the bone tissue of the proximal phalanges of hands in patients with suspected type I osteoporosis]. Minerva Ginecol 1994; 46:423-8. [PMID: 7970079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
The authors assessed the effectiveness and reliability of a new ultrasound system for evaluating the quality of bone tissue in a series of female patients with suspected type I osteoporosis. Evaluation with ultrasound was performed at the distal metaphysis of the first phalanx of the long fingers of the non-dominant hand. The investigation involves the measurement of the AD-SoS and the evaluation of the screen trace of the US signal transmitted through the phalanx. The data supplied by US were compared with the measurement of BMC through DPA on the ultradistal radius performed on the same day. The study involved 94 patients of age 42 to 73 years. A positive correlation was found between AD-SoS and BMC, r = 0.75, and a negative correlation between AD-SoS and the age of the patients, r = -0.62. Ultrasound investigation enables correct identification in 78% of patients; in particular, none of the patients recognized as pathologic at ultrasound investigation figured as normal at DPA. The authors conclude that the system studied is reliable and supplies important information on the quality of bone tissue, and can usefully complement the methods for measuring BMC.
Collapse
Affiliation(s)
- T Lusenti
- Divisione Nefrologia e Dialisi, Arcispedale S. Maria Nuova, Reggio Emilia
| | | | | | | | | | | |
Collapse
|
36
|
Macintyre IM, Currie JS, Smith DN, Anderson ID, Cadossi R. Reducing the risk of viral transmission at operation by electronic monitoring of the surgeon-patient barrier. Br J Surg 1994; 81:1076-8. [PMID: 7922071 DOI: 10.1002/bjs.1800810752] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
A new electronic device designed to detect glove holes, wet gowns and glove permeability was assessed during 50 general surgical operations. The cause of each alarm was recorded and the surgeon's awareness of any breach noted. Some 266 alarms were recorded of which 45 were ascribed to glove holes, 86 to wet gowns, 115 to glove porosity and 20 to other causes. Glove holes occurred in 29 of the 50 procedures; the surgeon was unaware of the hole in almost 70 per cent of cases. Holes were more common in laparotomy than in laparoscopic procedures (P = 0.006). In 20 per cent of instances surgeons did not respond immediately to the alarm (median delay 16 min). Six of eight surgeons who used the device indicated that they would do so regularly for major abdominal surgery. The electronic system accurately detects breaches in the surgeon-patient barrier. Its use should improve surgical discipline in acting to restore the barrier, protecting patient and surgeon alike.
Collapse
Affiliation(s)
- I M Macintyre
- Departments of Surgery, Western General Hospital, Edinburgh, UK
| | | | | | | | | |
Collapse
|
37
|
Abstract
There is evidence that electromagnetic stimulation may accelerate the healing of tissue damage following ischemia. We undertook this study to investigate the effects of low frequency pulsed electromagnetic field (PEMF) exposure on cerebral injury in a rabbit model of transient focal ischemia (2 h occlusion followed by 4 h of reperfusion). PEMF exposure (280 V, 75 Hz, IGEA Stimulator) was initiated 10 min after the onset of ischemia and continued throughout reperfusion (six exposed, six controls). Magnetic resonance imaging (MRI) and histology were used to measure the degree of ischemic injury. Exposure to pulsed electromagnetic field attenuated cortical ischemia edema on MRI at the most anterior coronal level by 65% (P < 0.001). On histologic examination, PEMF exposure reduced ischemic neuronal damage in this same cortical area by 69% (P < 0.01) and by 43% (P < 0.05) in the striatum. Preliminary data suggest that exposure to a PEMF of short duration may have implications for the treatment of acute stroke.
Collapse
Affiliation(s)
- G Grant
- Department of Neurosurgery, Stanford University, California 94305
| | | | | |
Collapse
|
38
|
Mammi GI, Rocchi R, Cadossi R, Massari L, Traina GC. The electrical stimulation of tibial osteotomies. Double-blind study. Clin Orthop Relat Res 1993:246-53. [PMID: 8458140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
The effect of electromagnetic field stimulation was investigated in a group of 40 consecutive patients treated with valgus tibial osteotomy for degenerative arthrosis of the knee. All patients were operated on by the same author and followed the same postoperative program. After surgery, patients were randomly assigned to a control group (dummy stimulators) or to a stimulated one (active stimulators). Four orthopedic surgeons, unaware of the experimental conditions, were asked to evaluate the roentgenograms taken 60 days postoperatively and to rate the osteotomy healing according to four categories (the fourth category being the most advanced stage of healing). In the control group, 73.6% of the patients were included in the first and second category. In the stimulated group, 72.2% of the patients were included in the third and fourth category. On a homogeneous group of patients, electromagnetic field stimulation had positive effects on the healing of tibial osteotomies.
Collapse
Affiliation(s)
- G I Mammi
- Department of Orthopaedics and Traumatology, Ospedale Civile C. Magati, Scandiano (RE), Italy
| | | | | | | | | |
Collapse
|
39
|
Cossarizza A, Angioni S, Petraglia F, Genazzani AR, Monti D, Capri M, Bersani F, Cadossi R, Franceschi C. Exposure to low frequency pulsed electromagnetic fields increases interleukin-1 and interleukin-6 production by human peripheral blood mononuclear cells. Exp Cell Res 1993; 204:385-7. [PMID: 8440336 DOI: 10.1006/excr.1993.1048] [Citation(s) in RCA: 68] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
The exposure of human peripheral blood mononuclear cells to extremely low frequency pulsed electromagnetic fields (PEMFs) increased both the spontaneous and the PHA- and TPA-induced production of interleukin-1 (IL-1) and IL-6. Our results suggest that cells of the monocytic lineage, which are good producers of both IL-1 and IL-6, can be important cellular targets for PEMFs. Taking into account that these cytokines are among the most pleiotropic ones, these data can help us understand the previous reported effects of PEMFs on the proliferation of human lymphocytes and the effects exerted by such fields on cartilage and bone cells, whose physiological activity is highly dependent on IL-1 and IL-6.
Collapse
Affiliation(s)
- A Cossarizza
- Institute of General Pathology, University of Modena, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|
40
|
Abstract
Human lymphocytes have been used by several researchers to investigate the biological effect of electromagnetic fields (EMF). EMF modulate the response by lymphocytes to lectin stimulation. The size and direction of the effect depends both on the lymphocyte physiology and on the physical parameters characterizing the EMF. Lymphocytes have also been used to investigate the genotoxicity of EMF exposure.
Collapse
Affiliation(s)
- R Cadossi
- Institute of Clinical Medicine II, University of Modena, Italy
| | | | | | | | | | | | | |
Collapse
|
41
|
Cossarizza A, Monti D, Bersani F, Scarfi MR, Zanotti M, Cadossi R, Franceschi C. Exposure to low-frequency pulsed electromagnetic fields increases mitogen-induced lymphocyte proliferation in Down's syndrome. Aging (Milano) 1991; 3:241-6. [PMID: 1837237 DOI: 10.1007/bf03324014] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
We previously reported that exposure of human mitogen-stimulated peripheral blood lymphocytes (PBL) to extremely low frequency pulsed electromagnetic fields (PEMFs) could restore the defective proliferative capability of PBL from aged subjects. The effects of exposure to PEMFs were studied in PBL from 25 patients with Down's syndrome (DS), a syndrome of premature aging characterized by precocious immune system derangement, including age-related defective PBL proliferative capability. PBL were stimulated with different doses of phytohemagglutinin, and cell proliferation was assessed by measuring the incorporation of tritiated thymidine. After PEMF-exposure, a significant increase in cell proliferation was observed in cells from DS children and young adults, but it was much more evident in PBL from relatively aged DS patients. The age-related effect of PEMFs on DS lymphocytes demonstrates that age must be considered a major variable when studies on DS are performed, and confirms that DS must be regarded as a syndrome of accelerated aging.
Collapse
Affiliation(s)
- A Cossarizza
- Institute of General Pathology, University of Modena School of Medicine, Italy
| | | | | | | | | | | | | |
Collapse
|
42
|
Scarfi MR, Bersani F, Cossarizza A, Monti D, Castellani G, Cadossi R, Franceschetti G, Franceschi C. Spontaneous and mitomycin-C-induced micronuclei in human lymphocytes exposed to extremely low frequency pulsed magnetic fields. Biochem Biophys Res Commun 1991; 176:194-200. [PMID: 1902102 DOI: 10.1016/0006-291x(91)90908-p] [Citation(s) in RCA: 48] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
The cytokinesis block micronucleus method, a very sensitive cytogenetic assay, was used to ascertain the possible genotoxic effects of extremely low frequency pulsed magnetic fields in phytohemagglutinin-stimulated human lymphocytes cultures from 16 healthy donors. Four conditions were studied: i) lymphocytes not exposed to the field (control cultures); ii) lymphocytes exposed to the field; iii) lymphocytes treated with mitomycin-C and not exposed to the field; iv) lymphocytes treated with mitomycin-C and exposed to the field. Mitomycin-C-treated cultures were used as control for the micronucleus method, because it is known that mitomycin-C is a potent genotoxic agent, capable of inducing micronuclei. The frequency of micronuclei in field-exposed cultures was similar to the spontaneous frequency observed in control unexposed-cultures. Moreover, the exposure to pulsed magnetic fields did not affect the frequency of micronuclei induced by mitomycin-C, suggesting that, in the experimental conditions used, this kind of field neither affected the integrity of chromosomes nor interfered with the genotoxic activity of mitomycin-C.
Collapse
Affiliation(s)
- M R Scarfi
- Istituto di Ricerca per l'Elettromagnetismo e i Componenti Elettronici Consiglio Nazionale delle Ricerche, Napoli, Italy
| | | | | | | | | | | | | | | |
Collapse
|
43
|
Cadossi R, Zucchini P, Emilia G, Franceschi C, Cossarizza A, Santantonio M, Mandolini G, Torelli G. Effect of low frequency low energy pulsing electromagnetic fields on mice injected with cyclophosphamide. Exp Hematol 1991; 19:196-201. [PMID: 1995311] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
C3H mice have been used to investigate the effect of a combination of cyclophosphamide (CY) and electromagnetic fields (PEMF). Mice were injected i.p. with a single dose of 200 mg/kg body weight of CY and then exposed to PEMF 24 h per day. In an initial series of experiments immediately after CY injection mice were exposed to PEMF until sacrifice. WBC counts in the peripheral blood demonstrated a quicker decline in WBC at days 1 and 2 in mice exposed to PEMF. Groups of mice were sacrificed at days 1, 4, 6, 8, and 10 after CY injection. In mice exposed to PEMF the spleen weight was less than in controls at days 6, 8, and 10. Autoradiographic studies demonstrated that the labeling index of bone marrow smears did not significantly differ between controls and experimental mice exposed to PEMF, whereas the spleen labeling index proved to be higher among control mice versus mice exposed to PEMF at day 6, and higher among mice exposed to PEMF versus controls at day 8. In a second series of experiments mice were exposed to PEMF only over the 24 h following CY injection. We found that the spleens of mice exposed to PEMF weighed less than those of controls at days 6 and 8. The labeling index of bone marrow did evidence a slight decrease among mice exposed to PEMF at days 8 and 10 after CY injection versus control mice. The spleen labeling index proved to be lower in experimental mice exposed to PEMF than in controls at days 4, 6, and 8. Mice were then injected with CY, half were exposed to PEMF, and 24 h later bone marrow was recovered from both groups of animals. The same number of bone marrow cells was injected via the tail vein into recipient mice irradiated to 8.5 Gy. The grafting efficiency of the bone marrow was evaluated by examining the number of spleen colonies and the spleen and bone marrow labeling indices at day 8; all parameters proved to be significantly lower among mice grafted with the bone marrow of mice injected with CY and exposed to PEMF than among controls injected with CY only. Finally, we found th at the effect of PEMF is evident only if mice are exposed during the 24 h following CY injection. The data reported here indicates that PEMF exposure after CY injection increases the damage induced in mice by CY.
Collapse
Affiliation(s)
- R Cadossi
- Department of Internal Medicine, University of Modena, Italy
| | | | | | | | | | | | | | | |
Collapse
|
44
|
Ieran M, Zaffuto S, Bagnacani M, Annovi M, Moratti A, Cadossi R. Effect of low frequency pulsing electromagnetic fields on skin ulcers of venous origin in humans: a double-blind study. J Orthop Res 1990; 8:276-82. [PMID: 2303961 DOI: 10.1002/jor.1100080217] [Citation(s) in RCA: 88] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
The effect of an electromagnetic field on the healing of skin ulcers of venous origin in humans has been investigated in a double-blind study. Forty-four patients have been admitted to the study; one-half were exposed to active stimulators (experimental group) and the remaining to dummy stimulators (control group). The stimulation was scheduled to last a maximum of 90 days. The success rate was significantly higher in the experimental group both at day 90 (p less than 0.02) and in the follow-up period (p less than 0.005). The data suggest that the effect of the electromagnetic field lasts even when the stimulation is over. No ulcers worsened in the experimental group, while four worsened in the control group. Twenty-five percent of the patients in the experimental group and 50% in the control group experienced recurrence of the ulcer. It is concluded that stimulation with an electromagnetic field is a useful adjunctive therapy in the management of these patients.
Collapse
Affiliation(s)
- M Ieran
- Department of Medical Angiology, Arcispedale S. Maria Nuova, Reggio Emilia, Italy
| | | | | | | | | | | |
Collapse
|
45
|
Cossarizza A, Monti D, Bersani F, Paganelli R, Montagnani G, Cadossi R, Cantini M, Franceschi C. Extremely low frequency pulsed electromagnetic fields increase interleukin-2 (IL-2) utilization and IL-2 receptor expression in mitogen-stimulated human lymphocytes from old subjects. FEBS Lett 1989; 248:141-4. [PMID: 2785933 DOI: 10.1016/0014-5793(89)80449-1] [Citation(s) in RCA: 96] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
The effects of the exposure of mitogen-stimulated human lymphocytes from aged subjects to low-frequency pulsed electromagnetic fields (PEMFs) were studied by measuring the production of interleukin-2 (IL-2) and the expression of IL-2 receptor. PEMF-exposed cultures that presented increased [3H]thymidine incorporation showed lower amounts of IL-2 in their supernatants, but higher percentages of IL-2 receptor-positive cells and of T-activated lymphocytes. Taken together, these data suggest that PEMFs were able to modulate mitogen-induced lymphocyte proliferation by provoking an increase in utilization of IL-2, most likely acting on the expression of its receptor on the plasma membrane.
Collapse
Affiliation(s)
- A Cossarizza
- Institute of General Pathology, University of Modena, Italy
| | | | | | | | | | | | | | | |
Collapse
|
46
|
Cossarizza A, Monti D, Bersani F, Cantini M, Cadossi R, Sacchi A, Franceschi C. Extremely low frequency pulsed electromagnetic fields increase cell proliferation in lymphocytes from young and aged subjects. Biochem Biophys Res Commun 1989; 160:692-8. [PMID: 2719691 DOI: 10.1016/0006-291x(89)92488-1] [Citation(s) in RCA: 111] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
The effect of the in vitro exposure to extremely low frequency pulsed electromagnetic fields (PEMFs) on the proliferation of human lymphocytes from 24 young and 24 old subjects was studied. The exposure to PEMFs during a 3-days culture period or during the first 24 hours was able to increase phytohaemagglutinin-induced lymphocyte proliferation in both groups. Such effect was greater in lymphocytes from old people which showed a markedly reduced proliferative capability and, after PEMF exposure, reached values of 3H-TdR incorporation similar to those of young subjects. The relevance of these data for the understanding and the reversibility of the proliferative defects in cells from aged subjects and for the assessment of risk related to the environmental exposure to PEMFs has to be considered.
Collapse
Affiliation(s)
- A Cossarizza
- Institute of General Pathology, University of Modena, Italy
| | | | | | | | | | | | | |
Collapse
|
47
|
Cossarizza A, Monti D, Sola P, Moschini G, Cadossi R, Bersani F, Franceschi C. DNA repair after gamma irradiation in lymphocytes exposed to low-frequency pulsed electromagnetic fields. Radiat Res 1989; 118:161-8. [PMID: 2468172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
The effect of exposure to extremely low-frequency pulsed electromagnetic fields (EMFs) on DNA repair capability and on cell survival in human lymphocytes damaged in vitro with gamma rays was studied by two different micromethods. In the first assay, which measures DNA repair synthesis (unscheduled DNA synthesis, UDS), lymphocyte cultures were stimulated with phytohemagglutinin (PHA) for 66 h and then treated with hydroxyurea (which blocks DNA replication), irradiated with 100 Gy of 60Co, pulsed with [3H]thymidine ([3H]TdR), and then exposed to pulsed EMFs for 6 h (the period in which cells repaired DNA damage). In the second assay, which measures cell survival after radiation or chemical damage, lymphocytes were first irradiated with graded doses of gamma rays or treated with diverse antiproliferative agents, and then stimulated with PHA, cultured for 72 h, and pulsed with [3H]TdR for the last 6 h of culture. In this case, immediately after the damage induced by either the radiation or chemicals, cultures were exposed to pulsed EMFs for 72 h, during which cell proliferation took place. Exposure to pulsed EMFs did not affect either UDS or cell survival, suggesting that this type of nonionizing radiation--to which humans may be exposed in the environment, and which is used for both diagnostic and therapeutic purposes--does not affect DNA repair mechanisms.
Collapse
Affiliation(s)
- A Cossarizza
- Institute of General Pathology, University of Modena, Italy
| | | | | | | | | | | | | |
Collapse
|
48
|
Cossarizza A, Monti D, Sola P, Moschini G, Cadossi R, Bersani F, Franceschi C. DNA Repair after γ Irradiation in Lymphocytes Exposed to Low-Frequency Pulsed Electromagnetic Fields. Radiat Res 1989. [DOI: 10.2307/3577431] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
49
|
Cadossi R, Hentz VR, Kipp J, Iverson R, Ceccherelli G, Zucchini P, Emilia G, Torelli G, Franceschi C, Eiverson R. Effect of low frequency low energy pulsing electromagnetic field (PEMF) on X-ray-irradiated mice. Exp Hematol 1989; 17:88-95. [PMID: 2643520] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
C3H/Km flora-defined mice were used to investigate the effect of exposure to pulsing electromagnetic field (PEMF) after total body x-ray irradiation. Prolonged exposure to PEMF had no effect on normal nonirradiated mice. When mice irradiated with different doses of x-ray (8.5 Gy, 6.8 Gy, and 6.3 Gy) were exposed to PEMF 24 h a day, we observed a more rapid decline in white blood cells (WBC) in the peripheral blood of mice exposed to PEMF at all the x-ray dosages used. No effect of exposure to PEMF was observed on the survival of the mice irradiated with 6.3 Gy and 8.5 Gy; in mice irradiated with 6.8 Gy, 2 out of 12 survived when exposed to PEMF as compared to 10 out of 12 control mice that were irradiated only. At day 4 after irradiation autoradiographic studies performed on bone marrow and spleen of 8.5-Gy-irradiated mice showed no difference between controls and mice exposed to PEMF, whereas on 6.8-Gy mice the bone marrow labeling index was lower in mice exposed to PEMF. In mice irradiated to 6.3 Gy we observed that the recovery of WBC in the peripheral blood was slowed in mice exposed to PEMF and their body weight was significantly lower than in control mice that were irradiated only. The spleen and bone marrow of the mice irradiated to 6.3 Gy and sacrificed at days 4, 14, 20, and 25 after irradiation were analyzed by autoradiography to evaluate the labeling index. Half of the spleens from mice sacrificed at day 25 after irradiation were used to evaluate the RNA content. Autoradiography showed that in the spleen and bone marrow of control mice, there were more cells labeled with [3H]thymidine at days 4 and 14 and less at days 20 and 25 after irradiation in comparison with mice irradiated and exposed to PEMF. The Northern blot analysis of histone H3 and p53 protein RNAs extracted from the spleens at day 25 after irradiation showed a slight increase in cycling cells among spleens of mice exposed to PEMF. We suggest that the exposure to PEMF immediately after x-ray irradiation results in increased damage.
Collapse
Affiliation(s)
- R Cadossi
- Stanford University Medical School, California
| | | | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Borsalino G, Bagnacani M, Bettati E, Fornaciari F, Rocchi R, Uluhogian S, Ceccherelli G, Cadossi R, Traina GC. Electrical stimulation of human femoral intertrochanteric osteotomies. Double-blind study. Clin Orthop Relat Res 1988:256-63. [PMID: 3191636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Low-frequency pulsing electromagnetic fields (PEMF) are being used in nonunion healing at several centers around the world. Much debate exists about quantification of PEMF effects, especially in humans where no randomized studies have been performed. The results of a double-blind treatment of 32 consecutive patients treated with femoral intertrochanteric osteotomy for hip degenerative arthritis are reported. Roentgenographic evaluation and callus density measurements performed with an image analyzer showed a statistically significant difference between controls and stimulated patients (p less than 0.01). In this extremely homogeneous patient population, PEMF stimulation favored osteotomy healing.
Collapse
Affiliation(s)
- G Borsalino
- Department of Orthopaedics and Traumatology, Montecchio Hospital, Reggio Emilia, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|