1
|
Endo-sinus bone gain following sinus membrane elevation without graft compared with sinus floor augmentation and a composite graft: a one-year single-blind randomized controlled trial. Int J Oral Maxillofac Surg 2024; 53:319-332. [PMID: 37891069 DOI: 10.1016/j.ijom.2023.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 10/06/2023] [Accepted: 10/11/2023] [Indexed: 10/29/2023]
Abstract
The objective of this study was to assess endo-sinus bone gain (ESBG) and bone density (BD) following maxillary sinus membrane elevation without graft (test) compared with maxillary sinus floor augmentation and 1:1 ratio of autogenous bone from the buccal antrostomy and deproteinized porcine bone mineral (control) using two- and three-dimensional radiographic methods. Forty healthy patients were randomly allocated to the test and control groups. Cone beam computed tomography scans were obtained at enrolment (T0), immediately after surgery (T1), at delivery of the prosthetic rehabilitation (T2), and 1 year after functional implant loading (T3). Mean differences were expressed with the 95% confidence interval. Significance was set at ≤ 0.05. ESBG and BD were significantly higher in the control group than test group at T1, T2, and T3 (P < 0.001). A significant decrease in ESBG and increase in BD was observed from T1 to T3 with both treatments (P < 0.001). There was a non-significant positive correlation of ESBG with implant protrusion length and non-significant negative correlation with residual bone height. In conclusion, test was associated with significantly lower ESBG and BD compared with control. However, the lower ESBG and BD did not appear to negatively affect the implant stability quotient or implant treatment outcome after 1 year of functional implant loading.
Collapse
|
2
|
Endo-sinus bone gain following osteotome-mediated sinus floor elevation with Bio-Oss Collagen compared with no grafting material: a one-year single-blind randomized controlled trial. Int J Oral Maxillofac Surg 2023; 52:1205-1215. [PMID: 36997448 DOI: 10.1016/j.ijom.2023.03.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 03/15/2023] [Accepted: 03/16/2023] [Indexed: 03/31/2023]
Abstract
The objective of this study was to assess endo-sinus bone gain (ESBG) following osteotome-mediated sinus floor elevation with Bio-Oss Collagen (test) compared with no grafting material (control) using two- and three-dimensional radiographic methods, as part of a randomized controlled trial (ClinicalTrials.gov, NCT04618900). Forty healthy patients who met the necessary eligibility criteria were allocated by block randomization to either the test group (20 patients) or control group (20 patients). Cone beam computed tomography scans were obtained at enrolment (T0), immediately after surgery (T1), at delivery of the prosthetic rehabilitation (T2), and 1 year after functional implant loading (T3). Mean differences were expressed with the 95% confidence interval; significance was set at P < 0.05. ESBG was significantly increased with Bio-Oss Collagen compared with no grafting material at T1, T2, and T3 (P < 0.001). A gradual decrease in ESBG was observed over time with both treatment modalities (P < 0.001), which diminished the difference between the test and control groups at T2 and T3. ESBG was observed to be positively correlated with implant protrusion length and negatively correlated with the residual bone height. In osteotome-mediated sinus floor elevation, the application of Bio-Oss Collagen underneath the elevated Schneiderian membrane improved ESBG significantly when compared with no grafting material. However, the increased ESBG seems not to have positively improved the treatment outcomes in terms of the implant stability quotient or the survival of the implants or suprastructures.
Collapse
|
3
|
Outcomes following osteotome-mediated sinus floor elevation with Bio-Oss Collagen or no grafting material: a one-year single-blind randomized controlled trial. Int J Oral Maxillofac Surg 2023:S0901-5027(23)00001-2. [PMID: 36639342 DOI: 10.1016/j.ijom.2022.12.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 12/20/2022] [Accepted: 12/21/2022] [Indexed: 01/13/2023]
Abstract
The objective of this single-blind randomized controlled trial was to test the hypothesis of no difference in implant treatment outcome and patient-reported outcome measures (PROMs) following osteotome-mediated sinus floor elevation with Bio-Oss Collagen (test) compared with no grafting material (control) after 1 year of implant loading. Forty healthy patients (27 female, 13 male) with a mean age of 49 years (range 24-74 years) were randomly allocated to the test or control group. Outcome measures included survival of the suprastructures and implants, peri-implant marginal bone loss, complications, and PROMs; the latter included the Oral Health Impact Profile-14 and a self-administered questionnaire with visual analogue scales to assess the peri-implant tissue, implant crown, function of the implant, total implant treatment outcome, and oral health-related quality of life. Mean differences were expressed with the standard deviation and 95% confidence interval. The level of significance was 0.05. Survival of the suprastructures and implants was 100% with both treatment modalities. No significant difference in any of the outcome measures was observed between the test and control groups. High patient satisfaction and a significant improvement in quality of life were observed with both treatment modalities. Consequently, no significant difference in implant treatment outcome between the test and control groups was revealed after 1 year of implant loading. Neither of the treatment modalities can therefore be considered better than the other.
Collapse
|
4
|
Diagnostic accuracy of cone beam computed tomography used for assessment of apical periodontitis: an ex vivo
histopathological study on human cadavers. Int Endod J 2018; 52:439-450. [DOI: 10.1111/iej.13020] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Accepted: 09/24/2018] [Indexed: 11/26/2022]
|
5
|
Buccal fat pad removal to improve facial aesthetics: an established technique? Med Oral Patol Oral Cir Bucal 2018; 23:e478-e484. [PMID: 29924767 PMCID: PMC6051676 DOI: 10.4317/medoral.22449] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2018] [Accepted: 05/04/2018] [Indexed: 11/14/2022] Open
Abstract
Background Buccal fat pad (BFP) is a singular structure between the facial muscles. Its removal may enhance the zygomatic prominences resulting in an inverted triangle of beauty. Objective: The aim of this study was to perform a systematic review of literature about BFP removal for facial aesthetic improvement. In order to answer the following research question: What are the indications, complication types and rates, surgical techniques and outcomes of the technique? Material and Methods The initial search in Pubmed, Scopus, and Cochrane databases recognized 220 articles. The final review included eight of them. None of the included studies were clinical trials. Results BPF removal was performed by intraoral incision or associated with the face lift procedure. In 71 patients submitted to the procedure and evaluated about complications, only 8.45% presented minor complications. Parotid duct and facial nerve injuries were not found. No study evaluated facial aging and long-term effects, therefore the harmless effect of the procedure to those features is not clear. Conclusions Although it is not a novel procedure, there is a lack of information about long-term outcomes. Thus, controlled clinical studies should be performed to achieve adequate clinical evidence of those aspects. Key words:Buccal fat pad, facial sculpting, cheek surgery, buccal lipectomy.
Collapse
|
6
|
Impact of cone beam computed tomography on periapical assessment and treatment planning five to eleven years after surgical endodontic retreatment. Int Endod J 2018; 51:729-737. [PMID: 29345849 DOI: 10.1111/iej.12888] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2017] [Accepted: 01/11/2018] [Indexed: 12/01/2022]
Abstract
AIM To evaluate how additional information from Cone Beam CT (CBCT) impacts on periapical assessment and treatment planning based on clinical examination and periapical radiographs (PR) in cases followed up five to eleven years after surgical endodontic retreatment (SER). METHODOLOGY Patients receiving SER during 2004-2010 were reinvited for follow-up examination including clinical examination, PR, and CBCT. In total, 108 patients (119 teeth) were reinvited, 74 patients (83 teeth) accepted to participate. Three observers initially assessed PR according to the four-scaled, increasing disease severity criteria by Rud et al. (International Journal of Oral Surgery, 1, 1972 and 195) and Molven et al. (International Journal of Oral and Maxillofacial Surgery, 16, and 432): 'Radiographic assessment A'. By including clinical information 'Treatment plan A' was made as follows: 1) no treatment, 2) further observation, 3) SER reoperation (SER-R), or 4) extraction. Hereafter, the CBCT volume was assessed and the information incorporated for 'Radiographic assessment B' followed by 'Treatment plan B'. Agreement between radiographic assessments and between treatment plans was recorded and assessed statistically by Stuart-Maxwell test for marginal homogeneity. RESULTS Nine teeth had been extracted; thus, the final analysis included 74 teeth (66 patients). The radiographic assessment was changed as a result of the CBCT evaluation in 38 cases (51.4%), of which 35 (47.3%) were to a higher Rud & Molven score, P < 0.001. The treatment plan was changed for 18 teeth (24.3%). For 14 teeth (18.9%), the change was from no treatment or further observation to a more invasive treatment plan (SER-R or extraction), P = 0.005. CONCLUSION The use of CBCT for long-term follow-up after SER led to more cases diagnosed with persisting or recurrent apical periodontitis and hence often to the recommendation of a more invasive treatment modality.
Collapse
|
7
|
Effect of avocado/soybean unsaponifiables on ligature-induced bone loss and bone repair after ligature removal in rats. J Periodontal Res 2016; 51:332-41. [PMID: 26248485 DOI: 10.1111/jre.12312] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/21/2015] [Indexed: 01/31/2023]
Abstract
BACKGROUND AND OBJECTIVE The aim of this study was to evaluate the effects of administration of avocado/soybean unsaponifiable (ASU), a drug that is commonly used in the treatment of rheumatoid arthritis, on ligature-induced bone loss and bone repair after ligature removal in rats. MATERIAL AND METHODS Eighty-four rats were randomly assigned to four groups of equal size and received a daily gavage of either sterile saline [control (CTR)] or ASU (0.6 mg/kg), starting 7 d before (ASU/-7), on the day of (ASU/0) or 7 d after (ASU/+7) periodontitis induction. Periodontitis was induced by placing silk ligatures into the gingival sulcus of the second maxillary molars for 7 d; after 7 d, the ligatures were removed. Seven rats from each group were sacrificed, 7, 15 or 30 d after ligature removal. Bone resorption was evaluated by histomorphometry and micro-computed tomography (micro-CT). Immunohistochemistry was used to evaluate the expression of TRAP, RANKL and alkaline phosphatase (ALP), and quantitative PCR (qPCR) was used to evaluate the levels of interleukin-1beta (Il1β), tumor necrosis factor alpha (Tnfα), interleukin-6 (Il-6), Rankl and Alp. Statistical analysis was performed using the Shapiro-Wilk test, ANOVA and Tukey's test for normal data, and using the Kruskall-Wallis and Dunnet's tests for non-normal data (p < 0.05). RESULTS Histomorphometry and micro-CT analysis showed greater bone resorption in the CTR group than in the ASU/0 (15 d) and ASU/+7 (7 and 15 d) groups. The CTR group also presented with a higher expression of TRAP (15 and 30 d) and RANKL (7 and 15 d) compared with ASU/0 and ASU/+7 groups. Similarly, qPCR analysis showed higher levels of Rankl and Il1β mRNAs, and lower levels of Alp mRNA, in the CTR group compared with all other groups (for all periods). CONCLUSION ASU exhibited a positive effect on bone repair following ligature-induced periodontitis in rats.
Collapse
|
8
|
Use of micro-computed tomography for the assessment of periapical lesions in small rodents: a systematic review. Int Endod J 2016; 50:352-366. [PMID: 26992821 DOI: 10.1111/iej.12633] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2015] [Accepted: 03/15/2016] [Indexed: 01/26/2023]
Abstract
This systematic review aimed to evaluate the literature on the acquisition-, reconstruction- and analysis parameters of micro-computed tomography (micro-CT) for the assessment of periapical lesions in rats and mice, and to illustrate the effect of variation in these parameters. The PubMed database was searched from 2000 to January 2015 (English-language publications) for reports on the use of micro-CT to evaluate periapical lesions in rats and mice. QUADAS criteria were used to rate the quality of the studies. To illustrate the effect of variations in acquisition-, reconstruction-, and analysis parameters on images of periapical lesions, micro-CT examination of two hemi-mandibles of mice, with periapical lesions around the first molar was undertaken. Twenty-one studies were identified, which analysed periapical lesions in rats or mice using micro-CT. According to the QUADAS, no study was classified as high-, seven were classified as moderate-, and 14 as low quality. The effect of variation in parameters was that voxel size may interfere with image sharpness, reconstruction may interfere with image sharpness and contrast, and inadequate plane orientation may alter the size of the periapical lesion. Nonpersonalized ROIs resulted in areas that were not part of the periapical lesion. Changing the limits of the threshold for bone-tissue visualization increased lesion size. There is no defined protocol for acquiring and analysing micro-CT images of periapical lesions in rats and mice. Furthermore, acquisition-, reconstruction- and analysis parameters are not adequately explained, which may compromise the scientific impact of the studies.
Collapse
|
9
|
Use of autogenous bone and beta-tricalcium phosphate in maxillary sinus lifting: a prospective, randomized, volumetric computed tomography study. Int J Oral Maxillofac Surg 2015; 44:1486-91. [PMID: 26232120 DOI: 10.1016/j.ijom.2015.07.003] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 03/21/2015] [Accepted: 07/09/2015] [Indexed: 11/16/2022]
Abstract
The correction of bone defects can be performed using autogenous or alloplastic materials, such as beta-tricalcium phosphate (β-TCP). This study compared the changes in bone volume (CBV) after maxillary sinus lifting using autogenous bone (n = 12), autogenous bone associated with β-TCP 1:1 (ChronOS; DePuy Synthes, Paoli, CA, USA) (n = 9), and β-TCP alone (n = 11) as grafting material, by means of cone beam computed tomography (CBCT). CBV was evaluated by comparing CBCT scans obtained in the immediate postoperative period (5-7 days) and at 6 months postoperative in each group using OsiriX software (OsiriX Foundation, Geneva, Switzerland). The results showed an average resorption of 45.7 ± 18.6% for the autogenous bone group, 43.8 ± 18.4% for the autogenous bone+β-TCP group, and 38.3 ± 16.6% for the β-TCP group. All bone substitute materials tested in this study presented satisfactory results for maxillary sinus lifting procedures regarding the maintenance of graft volume during the healing phase before the insertion of implants, as assessed by means of CBCT.
Collapse
|
10
|
In vitro biomechanical comparison of six different fixation methods following 5-mm sagittal split advancement osteotomies. Int J Oral Maxillofac Surg 2015; 44:984-8. [PMID: 25840861 DOI: 10.1016/j.ijom.2014.11.019] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2014] [Revised: 10/07/2014] [Accepted: 11/25/2014] [Indexed: 11/27/2022]
Abstract
The sagittal split ramus osteotomy (SSRO) is a surgical technique used widely to treat many congenital and acquired mandibular discrepancies. Stabilization of the osteotomy site and the potential for skeletal relapse after the procedure are still major problems. The aim of this study was to compare the mechanical stability of six methods of rigid fixation in SSRO using a biomechanical test model. Sixty polyurethane replicas of human hemimandibles were divided into six groups. In group I, the osteotomies were fixed with two four-hole titanium miniplates; in group II, with one four-hole miniplate; in group III, with one four-hole miniplate+a bicortical screw; in group IV, with a grid miniplate; in group V, with a four-hole locking miniplate; and in group VI, with a six-hole miniplate. A linear load in the premolar region was applied to the hemimandibles. The resistance forces (N) needed to displace the distal segment by 1, 3, and 5mm were recorded and the data transmitted from the load cell to a computer. One-way analysis of variance with Tukey's post hoc test was performed to compare the means between groups. For the three displacement conditions, there was a strong tendency for the 2.0-mm plate+screw and the grid plate to have higher values.
Collapse
|
11
|
Standardized method to quantify the variation in voxel value distribution in patient-simulated CBCT data sets. Dentomaxillofac Radiol 2014; 44:20140283. [PMID: 25354021 PMCID: PMC4614169 DOI: 10.1259/dmfr.20140283] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2014] [Revised: 09/29/2014] [Accepted: 10/28/2014] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To suggest a standardized method to assess the variation in voxel value distribution in patient-simulated CBCT data sets and the effect of time between exposures (TBE). Additionally, a measurement of reproducibility, Aarhus measurement of reproducibility (AMORe), is introduced, which could be used for quality assurance purposes. METHODS Six CBCT units were tested [Cranex(®) 3D/CRAN (Soredex Oy, Tuusula, Finland); Scanora(®) 3D/SCAN (Soredex Oy); NewTom™ 5G/NEW5 (QR srl, Verona, Italy); i-CAT/ICAT (Imaging Sciences International, Hatfield, PA); 3D Accuitomo FPD80/ACCU (Morita, Kyoto, Japan); and NewTom VG/NEWV (QR srl)]. Two sets of volumetric data of a wax-imbedded dry human skull (containing a titanium implant) were acquired by each CBCT unit at two sessions on separate days. Each session consisted 21 exposures: 1 "initial" followed by a 30-min interval (initial data set), 10 acquired with 30-min TBE (data sets 1-10) and 10 acquired with 15-min TBE (data sets 11-20). CBCT data were exported as digital imaging and communications in medicine files and converted to text files containing x, y and z positions and grey shade for each voxel. Subtractions were performed voxel-by-voxel in two set-ups: (1) between two consecutive data sets and (2) between any subsequent data set and data set 1. The mean grey shade variation for each voxel was calculated for each unit/session. RESULTS The largest mean grey shade variation was found in the subtraction set-up 2 (27-447 shades of grey, depending on the unit). Considering subtraction set-up 1, the highest variation was seen for NEW5, between data sets 1 and the initial. CONCLUSIONS Discrepancies in voxel value distribution were found by comparing the initial examination of the day with the subsequent examinations. TBE had no predictable effect on the variation of CBCT-derived voxel values. AMORe ranged between 0 and 64.
Collapse
|
12
|
Cone beam computed tomography and periapical lesions: a systematic review analysing studies on diagnostic efficacy by a hierarchical model. Int Endod J 2014; 48:815-28. [DOI: 10.1111/iej.12388] [Citation(s) in RCA: 68] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2014] [Accepted: 09/30/2014] [Indexed: 11/27/2022]
|
13
|
Radiographic diagnosis of dental restoration misfit: a systematic review. J Oral Rehabil 2014; 41:957-67. [PMID: 25142004 DOI: 10.1111/joor.12215] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/30/2014] [Indexed: 12/12/2022]
Abstract
The objective of this study was to perform a systematic review on the use of radiographic methods for the diagnosis of misfit in dental prostheses and restorations. The MEDLINE bibliographic database was searched from 1950 to February 2014 for reports on the radiographic diagnosis of misfits. The search strategy was limited to English-language publications using the following combined MeSH terms in the search strategy: (Dental Restoration OR Dental Prosthesis OR Crown OR Inlays OR Dental Abutments) and (Dental Leakage OR Prosthesis Fitting OR Dental Marginal Adaptation OR Surface Properties) and (Radiography, Dental OR Radiography, Dental, Digital OR Cone-Beam Computed Tomography). Twenty-eight publications were identified and read in full text, and 14 studies fulfilled criteria for inclusion. Information regarding the use of radiographic methods for the diagnosis of misfits in dental prosthesis and restorations, and in which the methodology/results comprised information regarding how the sample was collected/prepared, the method, imaging protocol, presence of a reference test and the outcomes were evaluated. QUADAS criteria was used to rate the studies in high, moderate or low quality. The evidence supporting the use of radiographic methods for the diagnosis of misfits in dental prosthesis and restorations is limited to low-/moderate-quality studies. The well-established intra-oral orthogonal projection is still under investigation and considered the most appropriate method, both when evaluating the relation between dental restoration to tooth and abutment to implant. Studies using digital radiographs have not evaluated the effect of image post-processing, and tomography has not been evaluated.
Collapse
|
14
|
Radiographic observers' ability to recognize patient movement during cone beam CT. Dentomaxillofac Radiol 2014; 43:20130449. [PMID: 24660954 DOI: 10.1259/dmfr.20130449] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To assess radiographic observers' ability to recognize patient movement during cone beam CT and to decide early termination of the examination. METHODS 100 patients were video-recorded during cone beam CT examination. Patients' videos were cropped twice: fitting the active 20-s examination time or the initial non-radiation 3 s of the examination. x- and y-coordinates of pre-defined points marked on the patient's face were used to define the reference standard for movement in the 20-s videos. A sample of 40 non-moving and 20 moving patients was selected. Eight observers scored the videos. The 3-s videos were scored: 0, the patient did not move; 1, the patient moved and the examination should be terminated. The 20-s videos were scored: 0, the patient did not move; 1, the patient moved. Re-assessment of 15% of the videos provided intra-observer reproducibility. The 20-s videos were compared with the reference standard providing sensitivity and specificity values (movement/non-movement recognition). The scores of the 3-s videos were compared with the scores of the 20-s videos. RESULTS Intra- and interobserver reproducibility ranged from substantial to almost perfect for both videos. The 20-s videos allowed patient movement recognition with a high specificity and a medium to high sensitivity. The 3-s videos allowed early termination of the examination with a small number of incorrect positive scores. The majority of the patients scored as moving in the 20-s videos were detected in the 3-s videos. CONCLUSIONS By observing video recordings, trained observers are able to recognize patient movement during cone beam CT examination with high specificity and to decide an early termination of the examination.
Collapse
|
15
|
Variation in voxel value distribution and effect of time between exposures in six CBCT units. Dentomaxillofac Radiol 2014; 43:20130376. [PMID: 24678846 DOI: 10.1259/dmfr.20130376] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The aim of this study is to assess the variation in voxel value distribution in volumetric data sets obtained by six cone beam CT (CBCT) units, and the effect of time between exposures. Six CBCT units [Cranex(®) 3D (CRAN; Soredex Oy, Tuusula, Finland), Scanora(®) 3D (SCAN; Soredex Oy), NewTom™ 5G (NEWT; QR Srl, Verona, Italy), Promax(®) Dimax 3 (Planmeca Oy, Helsinki, Finland), i-CAT (Imaging Sciences International, Hatfield, PA) and 3D Accuitomo FPD80 (Morita, Kyoto, Japan)] were tested. Two volumetric data sets of a dry human skull embedded in acrylic were acquired by each CBCT unit in two sessions on separate days. Each session consisted of 20 exposures: 10 acquired with 30 min between exposures and 10 acquired immediately one after the other. CBCT data were exported as digital imaging and communications in medicine (DICOM) files and converted to text files. The text files were re-organized to contain x-, y- and z-position and grey shade for each voxel. The files were merged to contain 1 record per voxel position, including the voxel values from the 20 exposures in a session. For each voxel, subtractions were performed between Data Set 1 and the remaining 19 data sets (1 - 2, 1 - 3, etc) in a session. Means, medians, ranges and standard deviations for grey shade variation in the subtraction data sets were calculated for each unit and session. For all CBCT units, variation in voxel values was observed throughout the 20 exposures. A "fingerprint" for the grey shade variation was observed for CRAN, SCAN and NEWT. For the other units, the variation was (apparently) randomly distributed. Large discrepancies in voxel value distribution are seen in CBCT images. This variation should be considered in studies that assess minute changes in CBCT images.
Collapse
|
16
|
Volumetric upper airway assessment in patients with transverse maxillary deficiency after surgically assisted rapid maxillary expansion. Int J Oral Maxillofac Surg 2013; 43:581-6. [PMID: 24361243 DOI: 10.1016/j.ijom.2013.11.002] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2013] [Revised: 08/20/2013] [Accepted: 11/04/2013] [Indexed: 11/27/2022]
Abstract
Transverse maxillary deficiency is commonly found in patients with sleep apnea and is also related to abnormal breathing patterns. Maxillary expansion procedures promote widening of the nasal floor and reduce the resistance to airflow, and have a positive influence on nasopharynx function. In order to evaluate volume changes in the upper airway, 15 adult patients with transverse maxillary deficiency underwent surgically assisted rapid maxillary expansion (RME) until a slight overcorrection of the crossbite was obtained. Cone beam computed tomography (CBCT) volumetric images were obtained at three predefined time points. The mean age of the patients was 30.2 (±7.4) years; nine were females and six were males. The area, volume, and the smallest transverse section area of the airway were assessed using Dolphin Imaging 3D software. Statistical comparisons were made of the changes between time periods. No statistically significant differences were found for volume or area. However a significant difference was found between the preoperative and immediate postoperative smallest transverse section area (P<0.05). Maxillary expansion, as an isolated procedure, does not result in a statistically significant improvement in the airway dimensions and results in an inferior relocation of the smallest transverse section area.
Collapse
|
17
|
Reproducibility of mandibular third molar assessment comparing two cone beam CT units in a matched pairs design. Dentomaxillofac Radiol 2013; 42:20130228. [PMID: 24052253 PMCID: PMC3853511 DOI: 10.1259/dmfr.20130228] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2013] [Revised: 09/04/2013] [Accepted: 09/17/2013] [Indexed: 11/05/2022] Open
Abstract
The aim of this study was to evaluate the reproducibility of the third molar assessment, comparing five observers and two cone beam CT (CBCT) units. 28 patients, each with two impacted mandibular third molars, were included. Each patient was randomly examined with a Scanora(®) 3D (Soredex, Helsinki, Finland) CBCT unit in one mandibular third molar region and with a Cranex(®) 3D (Soredex) CBCT unit in the other region. Five observers with varying CBCT experience assessed all third molars and recorded the following variables: number and morphology of the roots, relation to the mandibular canal in two directions, shape of the canal and whether there was a direct contact between the roots of the molar and the mandibular canal. The radiographic assessments were compared pairwise among all observers for all variables. Wilcoxon's signed-rank test was used to test the differences in observer accordance percentages among the recorded variables in the images from the two units, and kappa statistics expressed interobserver reproducibility. The mean percentages for observer accordance ranged from 65.4 to 92.9 for Scanora 3D and 60.3 to 94.8 for Cranex 3D. There was no significant difference between the observer accordance in the two CBCT units (p > 0.05), except for assessing root flex in the mesiodistal direction, for which the observer accordance was higher for Scanora 3D (p < 0.05). Kappa values ranged from 0.1 to 1.0 for Scanora 3D and from 0.2 to 0.9 for Cranex 3D. For the variable "direct contact", the interobserver reproducibility was excellent for the two trained radiologists. The two units had almost similar interobserver reproducibility for mandibular third molar assessment. Observer variation existed, and experienced radiologists demonstrated the highest interobserver reproducibility for canal-related variables.
Collapse
|
18
|
Comparison of changes in dental and bone radiographic densities in the presence of different soft-tissue simulators using pixel intensity and digital subtraction analyses. Dentomaxillofac Radiol 2013; 42:20130235. [PMID: 24005061 DOI: 10.1259/dmfr.20130235] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
OBJECTIVES To evaluate the influence of soft-tissue simulation materials on dental and bone tissue radiographic densities using pixel intensity (PI) and digital subtraction radiography (DSR) analyses. METHODS 15 dry human mandibles were divided into halves. Each half was radiographed using a charge-coupled device sensor without a soft-tissue simulation material (Wm) and with 5 types of materials: acrylic (Ac), wax (Wx), water (Wt), wood (Wd) and frozen bovine tissue (Bt). Three thicknesses were tested for each material: 10 mm, 15 mm and 20 mm. The material was positioned in front of the mandible and the sensor parallel to the molar region. The radiation beam was perpendicular to the sensor at 30 cm focal spot-to-object distance. The digital images of the bone and dental tissue were captured for PI analyses. The subtracted images were marked with 14 landmark magnifications, and 2 areas of analyses were defined, forming the regions of interest. Shapiro-Wilk and Kruskal-Wallis tests followed by Dunn's post-test were used (p < 0.05). RESULTS DSR showed that both the material type and the thickness tested influenced the gain of density in bone tissue (p < 0.05). PI analyses of the bone region did not show these differences, except for the lower density observed in the image without soft-tissue simulation material. In the dental region, both DSR and PI showed that soft-tissue simulators did not influence the density in these regions. CONCLUSIONS This study showed that the materials evaluated and their thicknesses significantly influenced the density-level gain in alveolar bone. In dental tissues, there was no density-level gain with any soft-tissue material tested.
Collapse
|
19
|
Effect of the number of screws on the stability of locking mandibular reconstruction plates. Int J Oral Maxillofac Surg 2013; 42:732-5. [DOI: 10.1016/j.ijom.2013.02.010] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2012] [Revised: 01/16/2013] [Accepted: 02/18/2013] [Indexed: 11/30/2022]
|
20
|
Cone beam CT image artefacts related to head motion simulated by a robot skull: visual characteristics and impact on image quality. Dentomaxillofac Radiol 2012; 42:32310645. [PMID: 22842641 DOI: 10.1259/dmfr/32310645] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES The aim of this study was to assess artefacts and their impact on cone beam CT (CBCT) image quality (IQ) after head motion simulated by a robot skull. METHODS A fully dentate human skull incorporated into a robot simulated pre-determined patient movements. Ten head motion patterns were selected based on the movement of the C-arm of the CBCT units (no motion as reference). Three CBCT units were used [a three-dimensional eXam (K) (KaVo Dental GmbH, Biberach, Germany), a Promax 3D MAX (P) (Planmeca Oy, Helsinki, Finland) and a Scanora(®) 3D (S) (Soredex Oy, Tuusula, Finland)]. Axial images were qualitatively assessed at three levels: mental foramen (MF), infraorbital foramen and supraorbital foramen, and artefacts characterized as stripe-like, double contours, unsharpness or ring-like. A 100 mm visual analogue scale (VAS) was used to quantitatively assess IQ. Cross-sectional images of the lower third molar and MF bilaterally were also evaluated by VAS. Four blinded examiners assessed the images. RESULTS For all units and motion patterns, stripe-like artefacts were the most common. The four observers agreed on the presence of at least one artefact type in 90% of the images. Axial images showed lower overall IQ after motion (VAS = 72.4 ± 24.0 mm) than reference images (VAS = 97.3 ± 2.6 mm). The most severe artefacts were seen at the MF level. For cross-sectional images, IQ was lowest after tremor. The mean IQ range was 74-89 and 57-90 for isolated (tilting, rotation and nodding) and combined (nodding + tilting and rotation + tilting) movements, respectively. IQ for MF was lower than for third molar for any movement except tremor. CONCLUSIONS Head motion of any type resulted in artefacts in CBCT images. The impact on IQ depended on the region and level in the skull.
Collapse
|
21
|
Evaluation of the RB-RB/LB-LB mnemonic rule for recording optimally projected intraoral images of dental implants: an in vitro study. Dentomaxillofac Radiol 2011; 41:298-304. [PMID: 22184473 DOI: 10.1259/dmfr/20861598] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVE The aim of this study was to evaluate a simple mnemonic rule (the RB-RB/LB-LB rule) for recording intra-oral radiographs with optimal projection for the control of dental implants. METHODS 30 third-year dental students received a short lesson in the RB-RB/LB-LB mnemonic rule. The rule is as follows: if right blur then raise beam (RB-RB), i.e. if implant threads are blurred at the right side of the implant, the X-ray beam direction must be raised towards the ceiling to obtain sharp threads on both implant sides; if left blur then lower beam (LB-LB), i.e. if implant threads are blurred at the left side of the implant, the X-ray beam direction must be lowered towards the floor to obtain sharp threads on both implant sides. Intra-oral radiographs of four screw-type implants placed with different inclination in a Frasaco upper or lower jaw dental model (Frasaco GmbH, Tettnang, Germany) were recorded. The students were unaware of the inclination of the implants and were instructed to re-expose each implant, implementing the mnemonic rule, until an image of the implant with acceptable quality (subjectively judged by the instructor) was obtained. Subsequently, each radiograph was blindly assessed with respect to sharpness of the implant threads and assigned to one of four quality categories: (1) perfect, (2) not perfect, but clinically acceptable, (3) not acceptable and (4) hopeless. RESULTS For all implants, from one non-perfect exposure to the following, a higher score was obtained in 64% of the cases, 28% received the same score and 8% obtained a lower score. Only a small variation was observed among exposures of implants with different inclination. On average, two exposures per implant (range: one to eight exposures) were needed to obtain a clinically acceptable image. CONCLUSION The RB-RB/LB-LB mnemonic rule for recording intra-oral radiographs of dental implants with a correct projection was easy to implement by inexperienced examiners.
Collapse
|