1
|
Flexible, scalable, high channel count stereo-electrode for recording in the human brain. Nat Commun 2024; 15:218. [PMID: 38233418 PMCID: PMC10794240 DOI: 10.1038/s41467-023-43727-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2022] [Accepted: 11/14/2023] [Indexed: 01/19/2024] Open
Abstract
Over the past decade, stereotactically placed electrodes have become the gold standard for deep brain recording and stimulation for a wide variety of neurological and psychiatric diseases. Current electrodes, however, are limited in their spatial resolution and ability to record from small populations of neurons, let alone individual neurons. Here, we report on an innovative, customizable, monolithically integrated human-grade flexible depth electrode capable of recording from up to 128 channels and able to record at a depth of 10 cm in brain tissue. This thin, stylet-guided depth electrode is capable of recording local field potentials and single unit neuronal activity (action potentials), validated across species. This device represents an advance in manufacturing and design approaches which extends the capabilities of a mainstay technology in clinical neurology.
Collapse
|
2
|
Editorial: Neuromodulation and neural technologies for sight restoration. Front Cell Neurosci 2023; 17:1304872. [PMID: 37915374 PMCID: PMC10616890 DOI: 10.3389/fncel.2023.1304872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Accepted: 10/03/2023] [Indexed: 11/03/2023] Open
|
3
|
Thermal safety considerations for implantable micro-coil design. J Neural Eng 2023; 20:10.1088/1741-2552/ace79a. [PMID: 37451256 PMCID: PMC10467159 DOI: 10.1088/1741-2552/ace79a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 07/14/2023] [Indexed: 07/18/2023]
Abstract
Micro magnetic stimulation of the brain via implantable micro-coils is a promising novel technology for neuromodulation. Careful consideration of the thermodynamic profile of such devices is necessary for effective and safe designs.Objective.We seek to quantify the thermal profile of bent wire micro-coils in order to understand and mitigate thermal impacts of micro-coil stimulation.Approach. In this study, we use fine wire thermocouples and COMSOL finite element modeling to examine the profile of the thermal gradients generated near bent wire micro-coils submerged in a water bath during stimulation. We tested a range of stimulation parameters previously reported in the literature such as voltage amplitude, stimulus frequency, stimulus repetition rate and coil wire materials.Main results. We found temperature increases ranging from <1 °C to 8.4 °C depending upon the stimulation parameters tested and coil wire materials used. Numerical modeling of the thermodynamics identified hot spots of the highest temperatures along the micro-coil contributing to the thermal gradients and demonstrated that these thermal gradients can be mitigated by the choice of wire conductor material and construction geometry.Significance. ISO standard 14708-1 designates a thermal safety limit of 2 °C temperature increase for active implantable medical devices. By switching the coil wire material from platinum/iridium to gold, our study achieved a 5-6-fold decrease in the thermal impact of coil stimulation. The thermal gradients generated from the gold wire coil were measured below the 2 °C safety limit for all stimulation parameters tested.
Collapse
|
4
|
MEMS micro-coils for magnetic neurostimulation. Biosens Bioelectron 2023; 227:115143. [PMID: 36805270 DOI: 10.1016/j.bios.2023.115143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Revised: 02/06/2023] [Accepted: 02/07/2023] [Indexed: 02/12/2023]
Abstract
Micro-coil magnetic stimulation of brain tissue presents new challenges for MEMS micro-coil probe fabrication. The main challenges are threefold; (i) low coil resistance for high power efficiency, (ii) low leak current from the probe into the in vitro experimental set-up, (iii) adaptive MEMS process technology because of the dynamic research area, which requires agile design changes. Taking on these challenges, we present a MEMS fabrication process that has three main features; (i) multilayer resist lift-off process to pattern up to 1800-nm-thick metal films, and special care is taken to obtain high conductivity thin-films by physical vapor deposition, and (ii) all micro-coil Al wires are encapsulated in at least 200 nm of ALD alumina and 6-μm-thick parylene C such the leak resistance is high (>210 GΩ), (iii) combining a multi-step DRIE process and maskless photolithography for adaptive design and device fabrication. The entire process requires four lithography steps. Because we avoided SOI wafers and lithography mask fabrication, the design-to-device time is shortened significantly. The resulting probes are 4-mm-long, 60-μm-thick, and down to 150 μm-wide. Selected MEMS coil devices were validated in vivo using mice and compared to previous work.
Collapse
|
5
|
Layer-dependent stability of intracortical recordings and neuronal cell loss. Front Neurosci 2023; 17:1096097. [PMID: 37090803 PMCID: PMC10113640 DOI: 10.3389/fnins.2023.1096097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 03/13/2023] [Indexed: 04/08/2023] Open
Abstract
Intracortical recordings can be used to voluntarily control external devices via brain-machine interfaces (BMI). Multiple factors, including the foreign body response (FBR), limit the stability of these neural signals over time. Current clinically approved devices consist of multi-electrode arrays with a single electrode site at the tip of each shank, confining the recording interface to a single layer of the cortex. Advancements in manufacturing technology have led to the development of high-density electrodes that can record from multiple layers. However, the long-term stability of neural recordings and the extent of neuronal cell loss around the electrode across different cortical depths have yet to be explored. To answer these questions, we recorded neural signals from rats chronically implanted with a silicon-substrate microelectrode array spanning the layers of the cortex. Our results show the long-term stability of intracortical recordings varies across cortical depth, with electrode sites around L4-L5 having the highest stability. Using machine learning guided segmentation, our novel histological technique, DeepHisto, revealed that the extent of neuronal cell loss varies across cortical layers, with L2/3 and L4 electrodes having the largest area of neuronal cell loss. These findings suggest that interfacing depth plays a major role in the FBR and long-term performance of intracortical neuroprostheses.
Collapse
|
6
|
Thermal effects on neurons during stimulation of the brain. J Neural Eng 2022; 19:056029. [PMID: 36126646 PMCID: PMC9855718 DOI: 10.1088/1741-2552/ac9339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 09/13/2022] [Accepted: 09/20/2022] [Indexed: 01/25/2023]
Abstract
All electric and magnetic stimulation of the brain deposits thermal energy in the brain. This occurs through either Joule heating of the conductors carrying current through electrodes and magnetic coils, or through dissipation of energy in the conductive brain.Objective.Although electrical interaction with brain tissue is inseparable from thermal effects when electrodes are used, magnetic induction enables us to separate Joule heating from induction effects by contrasting AC and DC driving of magnetic coils using the same energy deposition within the conductors. Since mammalian cortical neurons have no known sensitivity to static magnetic fields, and if there is no evidence of effect on spike timing to oscillating magnetic fields, we can presume that the induced electrical currents within the brain are below the molecular shot noise where any interaction with tissue is purely thermal.Approach.In this study, we examined a range of frequencies produced from micromagnetic coils operating below the molecular shot noise threshold for electrical interaction with single neurons.Main results.We found that small temperature increases and decreases of 1∘C caused consistent transient suppression and excitation of neurons during temperature change. Numerical modeling of the biophysics demonstrated that the Na-K pump, and to a lesser extent the Nernst potential, could account for these transient effects. Such effects are dependent upon compartmental ion fluxes and the rate of temperature change.Significance.A new bifurcation is described in the model dynamics that accounts for the transient suppression and excitation; in addition, we note the remarkable similarity of this bifurcation's rate dependency with other thermal rate-dependent tipping points in planetary warming dynamics. These experimental and theoretical findings demonstrate that stimulation of the brain must take into account small thermal effects that are ubiquitously present in electrical and magnetic stimulation. More sophisticated models of electrical current interaction with neurons combined with thermal effects will lead to more accurate modulation of neuronal activity.
Collapse
|
7
|
Micro-magnetic stimulation of primary visual cortex induces focal and sustained activation of secondary visual cortex. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2022; 380:20210019. [PMID: 35658677 DOI: 10.1098/rsta.2021.0019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2021] [Accepted: 10/01/2021] [Indexed: 06/15/2023]
Abstract
Cortical visual prostheses that aim to restore sight to the blind require the ability to create neural activity in the visual cortex. Electric stimulation delivered via microelectrodes implanted in the primary visual cortex (V1) has been the most common approach, although conventional electrodes may not effectively confine activation to focal regions and thus the acuity they create may be limited. Magnetic stimulation from microcoils confines activation to single cortical columns of V1 and thus may prove to be more effective than conventional microelectrodes, but the ability of microcoils to drive synaptic connections has not been explored. Here, we show that magnetic stimulation of V1 using microcoils induces spatially confined activation in the secondary visual cortex (V2) in mouse brain slices. Single-loop microcoils were fabricated using platinum-iridium flat microwires, and their effectiveness was evaluated using calcium imaging and compared with that of monopolar and bipolar electrodes. Our results show that compared to the electrodes, the microcoils better confined activation to a small region in V1. In addition, they produced more precise and sustained activation in V2. The finding that microcoil-based stimulation propagates to higher visual centres raises the possibility that complex visual perception, e.g. that requiring sustained synaptic inputs, may be achievable. This article is part of the theme issue 'Advanced neurotechnologies: translating innovation for health and well-being'.
Collapse
|
8
|
The Long-Term Stability of Intracortical Microstimulation and the Foreign Body Response Are Layer Dependent. Front Neurosci 2022; 16:908858. [PMID: 35769707 PMCID: PMC9234554 DOI: 10.3389/fnins.2022.908858] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Accepted: 05/16/2022] [Indexed: 11/24/2022] Open
Abstract
Intracortical microstimulation (ICMS) of the somatosensory cortex (S1) can restore sensory function in patients with paralysis. Studies assessing the stability of ICMS have reported heterogeneous responses across electrodes and over time, potentially hindering the implementation and translatability of these technologies. The foreign body response (FBR) and the encapsulating glial scar have been associated with a decay in chronic performance of implanted electrodes. Moreover, the morphology, intrinsic properties, and function of cells vary across cortical layers, each potentially affecting the sensitivity to ICMS as well as the degree of the FBR across cortical depth. However, layer-by-layer comparisons of the long-term stability of ICMS as well as the extent of the astrocytic glial scar change across cortical layers have not been well explored. Here, we implanted silicon microelectrodes with electrode sites spanning all the layers of S1 in rats. Using a behavioral paradigm, we obtained ICMS detection thresholds from all cortical layers for up to 40 weeks. Our results showed that the sensitivity and long-term performance of ICMS is indeed layer dependent. Overall, detection thresholds decreased during the first 7 weeks post-implantation (WPI). This was followed by a period in which thresholds remained stable or increased depending on the interfacing layer: thresholds in L1 and L6 exhibited the most consistent increases over time, while those in L4 and L5 remained the most stable. Furthermore, histological investigation of the tissue surrounding the electrode showed a biological response of microglia and macrophages which peaked at L1, while the area of the astrocytic glial scar peaked at L2/3. Interestingly, the biological response of these FBR markers is less exacerbated at L4 and L5, suggesting a potential link between the FBR and the long-term stability of ICMS. These findings suggest that interfacing depth can play an important role in the design of chronically stable implantable microelectrodes.
Collapse
|
9
|
Morphological Factors that Underlie Neural Sensitivity to Stimulation in the Retina. ADVANCED NANOBIOMED RESEARCH 2022; 1. [PMID: 35399546 DOI: 10.1002/anbr.202100069] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Retinal prostheses are a promising therapeutic intervention for patients afflicted by outer retinal degenerative diseases like retinitis pigmentosa and age-related macular degeneration. While significant advances in the development of retinal implants have been made, the quality of vision elicited by these devices remains largely sub-optimal. The variability in the responses produced by retinal devices is most likely due to the differences between the natural cell type-specific signaling that occur in the healthy retina vs. the non-specific activation of multiple cell types arising from artificial stimulation. In order to replicate these natural signaling patterns, stimulation strategies must be capable of preferentially activating specific RGC types. To design more selective stimulation strategies, a better understanding of the morphological factors that underlie the sensitivity to prosthetic stimulation must be developed. This review will focus on the role that different anatomical components play in driving the direct activation of RGCs by extracellular stimulation. Briefly, it will (1) characterize the variability in morphological properties of α-RGCs, (2) detail the influence of morphology on the direct activation of RGCs by electric stimulation, and (3) describe some of the potential biophysical mechanisms that could explain differences in activation thresholds and electrically evoked responses between RGC types.
Collapse
|
10
|
Morphological Factors that Underlie Neural Sensitivity to Stimulation in the Retina. ADVANCED NANOBIOMED RESEARCH 2021. [DOI: 10.1002/anbr.202170124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
|
11
|
Spiking Characteristics of Network-Mediated Responses Arising in Direction-Selective Ganglion Cells of Rabbit and Mouse Retinas to Electric Stimulation for Retinal Prostheses. IEEE Trans Neural Syst Rehabil Eng 2021; 29:2445-2455. [PMID: 34784280 PMCID: PMC8654582 DOI: 10.1109/tnsre.2021.3128878] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
To restore the sight of individuals blinded by outer retinal degeneration, numerous retinal prostheses have been developed. However, the performance of those implants is still hampered by some factors including the lack of comprehensive understanding of the electrically-evoked responses arising in various retinal ganglion cell (RGC) types. In this study, we characterized the electrically-evoked network-mediated responses (hereafter referred to as electric responses) of ON-OFF direction-selective (DS) RGCs in rabbit and mouse retinas for the first time. Interestingly, both species in common demonstrated strong negative correlations between spike counts of electric responses and direction selective indices (DSIs), suggesting electric stimulation activates inhibitory presynaptic neurons that suppress null direction responses for high direction tuning in their light responses. The DS cells of the two species showed several differences including different numbers of bursts. Also, spiking patterns were more heterogeneous across DS RGCs of rabbits than those of mice. The electric response magnitudes of rabbit DS cells showed positive and negative correlations with ON and OFF light response magnitudes to preferred direction motion, respectively. But the mouse DS cells showed positive correlations in both comparisons. Our Fano Factor (FF) and spike time tiling coefficient (STTC) analyses revealed that spiking consistencies across repeats were reduced in late electric responses in both species. Moreover, the response consistencies of DS RGCs were lower than those of non-DS RGCs. Our results indicate the species-dependent retinal circuits may result in different electric response features and therefore suggest a proper animal model may be crucial in prosthetic researches.
Collapse
|
12
|
MEMS inductor fabrication and emerging applications in power electronics and neurotechnologies. MICROSYSTEMS & NANOENGINEERING 2021; 7:59. [PMID: 34567771 PMCID: PMC8433479 DOI: 10.1038/s41378-021-00275-w] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 05/04/2021] [Accepted: 05/10/2021] [Indexed: 05/08/2023]
Abstract
MEMS inductors are used in a wide range of applications in micro- and nanotechnology, including RF MEMS, sensors, power electronics, and Bio-MEMS. Fabrication technologies set the boundary conditions for inductor design and their electrical and mechanical performance. This review provides a comprehensive overview of state-of-the-art MEMS technologies for inductor fabrication, presents recent advances in 3D additive fabrication technologies, and discusses the challenges and opportunities of MEMS inductors for two emerging applications, namely, integrated power electronics and neurotechnologies. Among the four top-down MEMS fabrication approaches, 3D surface micromachining and through-substrate-via (TSV) fabrication technology have been intensively studied to fabricate 3D inductors such as solenoid and toroid in-substrate TSV inductors. While 3D inductors are preferred for their high-quality factor, high power density, and low parasitic capacitance, in-substrate TSV inductors offer an additional unique advantage for 3D system integration and efficient thermal dissipation. These features make in-substrate TSV inductors promising to achieve the ultimate goal of monolithically integrated power converters. From another perspective, 3D bottom-up additive techniques such as ice lithography have great potential for fabricating inductors with geometries and specifications that are very challenging to achieve with established MEMS technologies. Finally, we discuss inspiring and emerging research opportunities for MEMS inductors.
Collapse
|
13
|
Microscale Physiological Events on the Human Cortical Surface. Cereb Cortex 2021; 31:3678-3700. [PMID: 33749727 PMCID: PMC8258438 DOI: 10.1093/cercor/bhab040] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Revised: 02/05/2021] [Accepted: 02/07/2021] [Indexed: 01/14/2023] Open
Abstract
Despite ongoing advances in our understanding of local single-cellular and network-level activity of neuronal populations in the human brain, extraordinarily little is known about their "intermediate" microscale local circuit dynamics. Here, we utilized ultra-high-density microelectrode arrays and a rare opportunity to perform intracranial recordings across multiple cortical areas in human participants to discover three distinct classes of cortical activity that are not locked to ongoing natural brain rhythmic activity. The first included fast waveforms similar to extracellular single-unit activity. The other two types were discrete events with slower waveform dynamics and were found preferentially in upper cortical layers. These second and third types were also observed in rodents, nonhuman primates, and semi-chronic recordings from humans via laminar and Utah array microelectrodes. The rates of all three events were selectively modulated by auditory and electrical stimuli, pharmacological manipulation, and cold saline application and had small causal co-occurrences. These results suggest that the proper combination of high-resolution microelectrodes and analytic techniques can capture neuronal dynamics that lay between somatic action potentials and aggregate population activity. Understanding intermediate microscale dynamics in relation to single-cell and network dynamics may reveal important details about activity in the full cortical circuit.
Collapse
|
14
|
The impact of synchronous versus asynchronous electrical stimulation in artificial vision. J Neural Eng 2021; 18. [PMID: 33900206 DOI: 10.1088/1741-2552/abecf1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2020] [Accepted: 03/09/2021] [Indexed: 11/12/2022]
Abstract
Visual prosthesis devices designed to restore sight to the blind have been under development in the laboratory for several decades. Clinical translation continues to be challenging, due in part to gaps in our understanding of critical parameters such as how phosphenes, the electrically-generated pixels of artificial vision, can be combined to form images. In this review we explore the effects that synchronous and asynchronous electrical stimulation across multiple electrodes have in evoking phosphenes. Understanding how electrical patterns influence phosphene generation to control object binding and perception of visual form is fundamental to creation of a clinically successful prosthesis.
Collapse
|
15
|
Layer-specific parameters of intracortical microstimulation of the somatosensory cortex. J Neural Eng 2021; 18. [PMID: 33706301 DOI: 10.1088/1741-2552/abedde] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 03/11/2021] [Indexed: 12/25/2022]
Abstract
Objective. Intracortical microstimulation of the primary somatosensory cortex (S1) has shown great progress in restoring touch sensations to patients with paralysis. Stimulation parameters such as amplitude, phase duration, and frequency can influence the quality of the evoked percept as well as the amount of charge necessary to elicit a response. Previous studies in V1 and auditory cortices have shown that the behavioral responses to stimulation amplitude and phase duration change across cortical depth. However, this depth-dependent response has yet to be investigated in S1. Similarly, to our knowledge, the response to microstimulation frequency across cortical depth remains unexplored.Approach. To assess these questions, we implanted rats in S1 with a microelectrode with electrode-sites spanning all layers of the cortex. A conditioned avoidance behavioral paradigm was used to measure detection thresholds and responses to phase duration and frequency across cortical depth.Main results. Analogous to other cortical areas, the sensitivity to charge and strength-duration chronaxies in S1 varied across cortical layers. Likewise, the sensitivity to microstimulation frequency was layer dependent.Significance. These findings suggest that cortical depth can play an important role in the fine-tuning of stimulation parameters and in the design of intracortical neuroprostheses for clinical applications.
Collapse
|
16
|
Spatially confined responses of mouse visual cortex to intracortical magnetic stimulation from micro-coils. J Neural Eng 2020; 17:056036. [PMID: 32998116 DOI: 10.1088/1741-2552/abbd22] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE Electrical stimulation via microelectrodes implanted in cortex has been suggested as a potential treatment for a wide range of neurological disorders. Despite some success however, the effectiveness of conventional electrodes remains limited, in part due to an inability to create specific patterns of neural activity around each electrode and in part due to challenges with maintaining a stable interface. The use of implantable micro-coils to magnetically stimulate the cortex has the potential to overcome these limitations because the asymmetric fields from coils can be harnessed to selectively activate some neurons, e.g. vertically-oriented pyramidal neurons while avoiding others, e.g. horizontally-oriented passing axons. In vitro experiments have shown that activation is indeed confined with micro-coils but their effectiveness in the intact brain of living animals has not been evaluated. APPROACH To assess the efficacy of stimulation, a 128-channel custom recording microelectrode array was positioned on the surface of the visual cortex (ECoG) in anesthetized mice and responses to magnetic and electric stimulation were compared. Stimulation was delivered from electrodes or micro-coils implanted through a hole in the center of the recording array at a rate of 200 pulses per second for 100 ms. MAIN RESULTS Both electric and magnetic stimulation reliably elicited cortical responses, although activation from electric stimulation was spatially expansive, often extending more than 1 mm from the stimulation site, while activation from magnetic stimulation was typically confined to a ∼300 µm diameter region around the stimulation site. Results were consistent for stimulation of both cortical layer 2/3 and layer 5 as well as across a range of stimulus strengths. SIGNIFICANCE The improved focality with magnetic stimulation suggests that the effectiveness of cortical stimulation can be improved. Improved focality may be particularly attractive for cortical prostheses that require high spatial resolution, e.g. devices that target sensory cortex, as it may lead to improved acuity.
Collapse
|
17
|
Differential Responses to High-Frequency Electrical Stimulation in Brisk-Transient and Delta Retinal Ganglion Cells. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:3529-3532. [PMID: 33018765 DOI: 10.1109/embc44109.2020.9175276] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Retinal microprostheses strive to evoke a sense of vision in individuals blinded by outer retinal degenerative diseases, by electrically stimulating the surviving retina. It is widely suspected that a stimulation strategy that can selectively activate different retinal ganglion cell types will improve the quality of evoked phosphenes. Previous efforts towards this goal demonstrated the potential for selective ON and OFF brisk-transient cell activation using high-rate (2000 pulses per second, PPS) stimulation. Here, we build upon this earlier work by testing an additional rate of stimulation and additional cell populations. We find considerable variability in responses both within and across individual cell types, but show that the sensitivity of a ganglion cell to repetitive stimulation is highly correlated to its single-pulse threshold. Consistent with this, we found thresholds for both stimuli to be correlated to soma size, and thus likely mediated by the properties of the axon initial segment. The ultimate efficacy of high-rate stimulation will likely depend on several factors, chief among which are (a) the residual ganglion types, and (b) the stimulation frequency.
Collapse
|
18
|
Response Profiles of Retinal Ganglion Cells to Sinusoidal Electric Stimulation vary for Low vs. High Frequencies. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:3533-3536. [PMID: 33018766 DOI: 10.1109/embc44109.2020.9175373] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Microelectronic retinal prostheses electrically stimulate retinal neurons with the goal of restoring vision in patients blinded by outer retinal degeneration. Despite some success in clinical trials, the quality of vision elicited by these devices is still limited. To improve the performance of retinal prostheses, our group studied how retinal neurons respond to electric stimulation. Our previous work showed that responses of retinal ganglion cells (RGCs) are frequency-dependent and different types of RGCs can be preferentially activated with a specific frequency and current amplitude. In the present study, we systemically examined responses of RGCs to sinusoidal electric stimulation with varying frequencies and amplitudes. We found that ON sustained alpha RGCs show distinct stimulus-response relationships to low and high frequency stimulation. For example, RGCs showed monotonic response curves to 500 Hz sinusoidal stimulation, whereas they showed non-monotonic response curves to 2000 Hz stimulation. We also described how increasing stimulus frequency gradually changed the response curves of RGCs.
Collapse
|
19
|
Tailoring of the axon initial segment shapes the conversion of synaptic inputs into spiking output in OFF-α T retinal ganglion cells. SCIENCE ADVANCES 2020; 6:6/37/eabb6642. [PMID: 32917708 PMCID: PMC7486099 DOI: 10.1126/sciadv.abb6642] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2020] [Accepted: 07/29/2020] [Indexed: 06/11/2023]
Abstract
Recently, mouse OFF-α transient (OFF-α T) retinal ganglion cells (RGCs) were shown to display a gradient of light responses as a function of position along the dorsal-ventral axis; response differences were correlated to differences in the level of excitatory presynaptic input. Here, we show that postsynaptic differences between cells also make a strong contribution to response differences. Cells in the dorsal retina had longer axon initial segments (AISs)-the greater number of Nav1.6 channels in longer AISs directly mediates higher rates of spiking and helps avoid depolarization block that terminates spiking in ventral cells with shorter AISs. The pre- and postsynaptic specializations that shape the output of OFF-α T RGCs interact in different ways: In dorsal cells, strong inputs and the long AISs are both necessary to generate their strong, sustained spiking outputs, while in ventral cells, weak inputs or the short AISs are both sufficient to limit the spiking signal.
Collapse
|
20
|
Retinal Degeneration Reduces Consistency of Network-Mediated Responses Arising in Ganglion Cells to Electric Stimulation. IEEE Trans Neural Syst Rehabil Eng 2020; 28:1921-1930. [PMID: 32746297 PMCID: PMC7518787 DOI: 10.1109/tnsre.2020.3003345] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Retinal prostheses use periodic repetition of electrical stimuli to form artificial vision. To enhance the reliability of evoked visual percepts, repeating stimuli need to evoke consistent spiking activity in individual retinal ganglion cells (RGCs). However, it is not well known whether outer retinal degeneration alters the consistency of RGC responses. Hence, here we systematically investigated the trial-to-trial variability in network-mediated responses as a function of the degeneration level. We patch-clamp recorded spikes in ON and OFF types of alpha RGCs from r d10 mice at four different postnatal days (P15, P19, P31, and P60), representing distinct stages of degeneration. To assess the consistency of responses, we analyzed variances in spike count and timing across repeats of the same stimulus delivered multiple times. We found the trial-to-trial variability of network-mediated responses increased considerably as the disease progressed. Compared to responses taken before degeneration onset, those of degenerate retinas showed up to ~70% higher variability (Fano Factor) in spike counts (p < 0.001) and ~95% lower correlation level in spike timing (p < 0.001). These results indicate consistency weakens significantly in electrically-evoked network-mediated responses and therefore raise concerns about the ability of microelectronic retinal implants to elicit consistent visual percepts at advanced stages of retinal degeneration.
Collapse
|
21
|
The relationship between morphological properties and thresholds to extracellular electric stimulation in α RGCs. J Neural Eng 2020; 17:045015. [PMID: 32736374 DOI: 10.1088/1741-2552/abab47] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
OBJECTIVE Retinal prostheses strive to restore vison to patients that are blind from retinal degeneration by electrically stimulating surviving retinal ganglion cells (RGCs). The quality of elicited percepts remains limited however and it is desirable to develop improved stimulation strategies. Here, we examine how the anatomical and biophysical properties of RGCs influence activation thresholds, including the effects of variations found naturally. APPROACH Detailed reconstructions were made of a large number of mouse α RGCs and were used to create an array of model cells; the models were used to study the effects of individual anatomical features on activation threshold to electric stimulation. Stimulation was delivered epiretinally from a point-source or disk electrode and consisted of monophasic or biphasic rectangular pulses. MAIN RESULTS Modeling results show that the region of minimum threshold always is within the axon initial segment (AIS). The properties of this region as well as the absolute value of the minimum threshold are dependent on the length of the AIS as well as on the relative composition of sodium channels within the AIS. Other morphological features, including cell size, dendritic field size and the distance between the AIS and the soma had only a minimal influence on thresholds. Introducing even a small number of low-threshold Nav1.6 channels into the AIS was sufficient to lower minimum thresholds substantially although further increases in Nav1.6 had diminishing effects. The distance between the AIS and the electrode affects threshold levels while alignment of the electrode with the axon or dendritic parts of the RGC can result in lower thresholds, even if the distance to the cell remains the same. SIGNIFICANCE Intrinsic morphological features can influence activation thresholds with the AIS having the strongest influence. However, the combined influence remains limited and may not be large enough to allow for selective activation between different RGC types.
Collapse
|
22
|
Noninvasive Electrical Stimulation Improves Photoreceptor Survival and Retinal Function in Mice with Inherited Photoreceptor Degeneration. Invest Ophthalmol Vis Sci 2020; 61:5. [PMID: 32271885 PMCID: PMC7401948 DOI: 10.1167/iovs.61.4.5] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Purpose Neurons carry electrical signals and communicate via electrical activities. The therapeutic potential of electrical stimulation (ES) for the nervous system, including the retina, through improvement of cell survival and function has been noted. Here we investigated the neuroprotective and regenerative potential of ES in a mouse model of inherited retinal degeneration. Methods Rhodopsin-deficient (Rho−/−) mice received one or two sessions of transpalpebral ES or sham treatments for 7 consecutive days. Intraperitoneal injection of 5-ethynyl-2′-deoxyuridine was used to label proliferating cells. Weekly electroretinograms were performed to monitor retinal function. Retinal morphology, photoreceptor survival, and regeneration were evaluated in vivo using immunohistochemistry and genetic fate-mapping techniques. Müller cell (MC) cultures were employed to further define the optimal conditions of ES application. Results Noninvasive transpalpebral ES in Rho−/− mice improved photoreceptor survival and electroretinography function in vivo. ES also triggered residential retinal progenitor-like cells such as MCs to reenter the cell cycle, possibly producing new photoreceptors, as shown by immunohistochemistry and genetic fate-mapping techniques. ES directly stimulated cell proliferation and the expression of progenitor cell markers in MC cultures, at least partially through bFGF signaling. Conclusions Our study showed that transpalpebral ES improved photoreceptor survival and retinal function and induced the proliferation, probably photoreceptor regeneration, of MCs; this occurs via stimulation of the bFGF pathways. These results suggest the exciting possibility of applying noninvasive ES as a versatile tool for preventing photoreceptor loss and mobilizing endogenous progenitors for reversing vision loss in patients with photoreceptor degeneration.
Collapse
|
23
|
Comparison of electrically elicited responses in rabbit and mouse retinal ganglion cells. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:1813-1816. [PMID: 31946249 DOI: 10.1109/embc.2019.8857504] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Retinal implants are currently the only commercially available devices that can restore vision in patients suffering from a wide range of outer retinal degenerations. In order to improve the clinical outcome, i.e. the quality of elicited vision, a large number of in-vitro experiments probing the impact of electric stimulation on activation of the retina have been conducted. In these studies, however, retinas from many different species have been used which impedes comparisons between studies. Therefore, we measured the responses from four major ganglion cell types to light and electric stimulation in rabbit and mouse retina and compared their responses. We found strong similarities between the two species in transient cells whereas responses in sustained cell types typically did not match as well.
Collapse
|
24
|
Comparison of responses of visual cortical neurons in the mouse to intraocular and extraocular electric stimulation of the retina. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2019; 2018:2458-2461. [PMID: 30440905 DOI: 10.1109/embc.2018.8512795] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Retinal implants offered the promise of restoring functional vision to the blind via the delivery of electrical stimulation to the retina. To enhance the efficacy of these devices, stimulation should elicit neural responses that are similar to the responses that occur naturally in the retina as these have the best chance of carrying a robust signal to visual cortex. A corollary of this is that the responses that arise in visual cortical neurons can be used to compare the effectiveness of different stimulation strategies in the retina. Here, we studied how visual cortical neurons in the mouse respond to monophasic cathodal and anodal electric stimulation delivered via a wire electrode positioned on the outer surface of the eye (extraocular) or within the vitreous cavity of the eye (intraocular). Responses of visual cortical neurons were recorded from primary visual cortex on the side contralateral to the stimulatated eye. For both stimulation modalities, response patterns consisted of a brief burst of spikes followed by a 400-500 ms period of inhibition. Both modalities also elicited stronger responses to cathodal stimuli (vs. anodal). The preferential sensitivity to cathodal stimuli is similar to that of epiretinal stimulation (anodal stimuli are more effective with sub-retinal stimulation) suggest the extraocular approach mirrors epiretinal stimulation. Extraocular stimulation also showed some response characteristics that were different from those observed in the retina, e.g., at very strong amplitudes, cathodal and anodal stimulation produced similar responses.
Collapse
|
25
|
Scaling of the AIS and Somatodendritic Compartments in α S RGCs. Front Cell Neurosci 2019; 13:436. [PMID: 31611777 PMCID: PMC6777007 DOI: 10.3389/fncel.2019.00436] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2019] [Accepted: 09/13/2019] [Indexed: 11/21/2022] Open
Abstract
The anatomical properties of the axon initial segment (AIS) are tailored in certain types of CNS neurons to help optimize different aspects of neuronal function. Here, we questioned whether the AISs of retinal ganglion cells (RGC) were similarly customized, and if so, whether they supported specific RGC functions. To explore this, we measured the AIS properties in alpha sustained RGCs (α S RGCs) of mouse; α S RGCs sizes vary systematically along the nasal temporal axis of the retina, making these cells an attractive population with which to study potential correlations between AIS properties and cell size. Measurements of AIS length as well as distance from the soma revealed that both were scaled to cell size, i.e., cells with large dendritic fields had long AISs that were relatively far from the soma. Within the AIS, the percentage of Na v 1.6 voltage-gated sodium channels remained highly consistent, regardless of cell size or other AIS properties. Although ON RGCs were slightly larger than OFF cells at any given location of the retina, the level of scaling and relative distribution of voltage-gated sodium channels were highly similar. Computational modeling revealed that AIS scaling influenced spiking thresholds, spike rate as well as the kinetics of individual action potentials, Interestingly, the effect of individual features of the AIS varied for different neuronal functions, e.g., AIS length had a larger effect on the efficacy by which the AIS initiated spike triggered the somatic spike than it did on repetitive spiking. The polarity of the effect varied for different properties, i.e., increases to soma size increased spike threshold while increases to AIS length decreased threshold. Thus, variations in the relative level of scaling for individual components could fine tune threshold or other neuronal functions. Light responses were highly consistent across the full range of cell sizes suggesting that scaling may post-synaptically shape response stability, e.g., in addition to several well-known pre-synaptic contributors.
Collapse
|
26
|
Selective Formation of Porous Pt Nanorods for Highly Electrochemically Efficient Neural Electrode Interfaces. NANO LETTERS 2019; 19:6244-6254. [PMID: 31369283 PMCID: PMC7174248 DOI: 10.1021/acs.nanolett.9b02296] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The enhanced electrochemical activity of nanostructured materials is readily exploited in energy devices, but their utility in scalable and human-compatible implantable neural interfaces can significantly advance the performance of clinical and research electrodes. We utilize low-temperature selective dealloying to develop scalable and biocompatible one-dimensional platinum nanorod (PtNR) arrays that exhibit superb electrochemical properties at various length scales, stability, and biocompatibility for high performance neurotechnologies. PtNR arrays record brain activity with cellular resolution from the cortical surfaces in birds and nonhuman primates. Significantly, strong modulation of surface recorded single unit activity by auditory stimuli is demonstrated in European Starling birds as well as the modulation of local field potentials in the visual cortex by light stimuli in a nonhuman primate and responses to electrical stimulation in mice. PtNRs record behaviorally and physiologically relevant neuronal dynamics from the surface of the brain with high spatiotemporal resolution, which paves the way for less invasive brain-machine interfaces.
Collapse
|
27
|
Mediating Retinal Ganglion Cell Spike Rates Using High-Frequency Electrical Stimulation. Front Neurosci 2019; 13:413. [PMID: 31114476 PMCID: PMC6503046 DOI: 10.3389/fnins.2019.00413] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Accepted: 04/11/2019] [Indexed: 12/30/2022] Open
Abstract
Recent retinal studies have directed more attention to sophisticated stimulation strategies based on high-frequency (>1.0 kHz) electrical stimulation (HFS). In these studies, each retinal ganglion cell (RGC) type demonstrated a characteristic stimulus-strength-dependent response to HFS, offering the intriguing possibility of focally targeting retinal neurons to provide useful visual information by retinal prosthetics. Ionic mechanisms are known to affect the responses of electrogenic cells during electrical stimulation. However, how these mechanisms affect RGC responses is not well understood at present, particularly when applying HFS. Here, we investigate this issue via an in silico model of the RGC. We calibrate and validate the model using an in vitro retinal preparation. An RGC model based on accurate biophysics and realistic representation of cell morphology, was used to investigate how RGCs respond to HFS. The model was able to closely replicate the stimulus-strength-dependent suppression of RGC action potentials observed experimentally. Our results suggest that spike inhibition during HFS is due to local membrane hyperpolarization caused by outward membrane currents near the stimulus electrode. In addition, the extent of HFS-induced inhibition can be largely altered by the intrinsic properties of the inward sodium current. Finally, stimulus-strength-dependent suppression can be modulated by a wide range of stimulation frequencies, under generalized electrode placement conditions. In vitro experiments verified the computational modeling data. This modeling and experimental approach can be extended to further our understanding on the effects of novel stimulus strategies by simulating RGC stimulus-response profiles over a wider range of stimulation frequencies and electrode locations than have previously been explored.
Collapse
|
28
|
Response of Mouse Visual Cortical Neurons to Electric Stimulation of the Retina. Front Neurosci 2019; 13:324. [PMID: 31019449 PMCID: PMC6459047 DOI: 10.3389/fnins.2019.00324] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2019] [Accepted: 03/21/2019] [Indexed: 12/27/2022] Open
Abstract
Retinal prostheses strive to restore vision to the blind by electrically stimulating the neurons that survive the disease process. Clinical effectiveness has been limited however, and much ongoing effort is devoted toward the development of improved stimulation strategies, especially ones that better replicate physiological patterns of neural signaling. Here, to better understand the potential effectiveness of different stimulation strategies, we explore the responses of neurons in the primary visual cortex to electric stimulation of the retina. A 16-channel implantable microprobe was used to record single unit activities in vivo from each layer of the mouse visual cortex. Layers were identified by electrode depth as well as spontaneous rate. Cell types were classified as excitatory or inhibitory based on their spike waveform and as ON, OFF, or ON-OFF based on the polarity of their light response. After classification, electric stimulation was delivered via a wire electrode placed on the surface of cornea (extraocularly) and responses were recorded from the cortex contralateral to the stimulated eye. Responses to electric stimulation were highly similar across cell types and layers. Responses (spike counts) increased as a function of the amplitude of stimulation, and although there was some variance across cells, the sensitivity to amplitude was largely similar across all cell types. Suppression of responses was observed for pulse rates ≥3 pulses per second (PPS) but did not originate in the retina as RGC responses remained stable to rates up to 5 PPS. Low-frequency sinusoids delivered to the retina replicated the out-of-phase responses that occur naturally in ON vs. OFF RGCs. Intriguingly, out-of-phase signaling persisted in V1 neurons, suggesting key aspects of neural signaling are preserved during transmission along visual pathways. Our results describe an approach to evaluate responses of cortical neurons to electric stimulation of the retina. By examining the responses of single cells, we were able to show that some retinal stimulation strategies can indeed better match the neural signaling patterns used by the healthy visual system. Because cortical signaling is better correlated to psychophysical percepts, the ability to evaluate which strategies produce physiological-like cortical responses may help to facilitate better clinical outcomes.
Collapse
|
29
|
Micro-Coil Design Influences the Spatial Extent of Responses to Intracortical Magnetic Stimulation. IEEE Trans Biomed Eng 2018; 66:1680-1694. [PMID: 30369434 DOI: 10.1109/tbme.2018.2877713] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
OBJECTIVE Electrical stimulation via cortically implanted electrodes has been proposed to treat a wide range of neurological disorders. Effectiveness has been limited, however, in part due to the inability of conventional electrodes to activate specific types of neurons while avoiding other types. Recent demonstrations that magnetic stimulation from a micro-coil can selectively activate pyramidal neurons (PNs) while avoiding passing axons suggest the possibility that such an approach can overcome some this limitation and here we use computer simulations to explore how the micro-coil design influences the selectivity with which neurons are activated. METHODS A computational model was developed to compare the selectivity of magnetic stimulation induced by rectangular-, V-, and W-shaped coil designs. The more promising designs (V- and W-shapes) were fabricated for use in electrophysiological experiments including in vitro patch-clamp recording and calcium imaging (GCaMP6f) of mouse brain slices. RESULTS Both V- and W-shaped coils reliably activated layer 5 (L5) PNs but V-coils were more effective while W-coils were more selective. Activation thresholds with double-loop coils were approximately one-half those of single-loop coils. Calcium imaging revealed that both V- and W-coils better confine activation than electrodes. CONCLUSION Individual design features can influence both the strength as well as the selectivity of micro-coils and can be accurately predicted by computer simulations. SIGNIFICANCE Our results show that how coil design influences the response of cortical neurons to stimulation and are an important step toward the development of next-generation cortical prostheses.
Collapse
|
30
|
Network-mediated responses of ON ganglion cells to electric stimulation become less consistent across trials during retinal degeneration. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2017:2114-2117. [PMID: 29060314 DOI: 10.1109/embc.2017.8037271] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Microelectronic retinal prostheses are being developed to restore sight in individuals blinded by outer retinal degenerative diseases such as retinitis pigmentosa and age-related macular degeneration. Unfortunately, the quality of vision restored by these devices is still limited. To improve the quality of elicited vision, our group studies the responses of retinal neurons to electric stimulation. Our previous work showed that responses mediated through the retinal network are reproducible with high temporal precision, even for spikes that occur >100 ms after stimulus onset. Because they arise through the network, it is important to understand whether such reliability changes in the degenerate retina. Here, we examined response variability at several different stages of degeneration: postnatal day 14 (P14), P18, P31 and P60 in a well-established mouse model of degeneration (rd10). Spiking responses of ON alpha RGCs were recorded multiple times to an identical electric stimulus. We found that the trial-to-trial variability increased over the course of retinal degeneration. This finding may help to explain the reported variability in the quality of elicited vision across subjects using these devices.
Collapse
|
31
|
Visual and electric spiking responses of seven types of rabbit retinal ganglion cells. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:2434-2437. [PMID: 30440899 DOI: 10.1109/embc.2018.8512746] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Electric stimulation of the retina via retinal implants is currently the only commercially available method to restore vision in patients suffering from a wide range of outer retinal degenerations. To improve the quality of retinal implants, it is desirable to better understand how different retinal cell classes and types respond to electric stimuli so that more effective stimulation strategies can be developed. Here, we measured the response of seven major types of retinal ganglion cells to electric stimulation. A simple series of light stimuli were used to classify cells into known types. Electric stimulation produced unique responses in almost all ganglion cell types and the electric responses typically matched elements of the corresponding light responses.
Collapse
|
32
|
Electric stimulus duration alters network-mediated responses depending on retinal ganglion cell type. J Neural Eng 2018; 15:036010. [PMID: 29415876 DOI: 10.1088/1741-2552/aaadc1] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
OBJECTIVE To improve the quality of artificial vision that arises from retinal prostheses, it is important to bring electrically-elicited neural activity more in line with the physiological signaling patterns that arise normally in the healthy retina. Our previous study reported that indirect activation produces a closer match to physiological responses in ON retinal ganglion cells (RGCs) than in OFF cells (Im and Fried 2015 J. Physiol. 593 3677-96). This suggests that a preferential activation of ON RGCs would shape the overall retinal response closer to natural signaling. Recently, we found that changes to the rate at which stimulation was delivered could bias responses towards a stronger ON component (Im and Fried 2016a J. Neural Eng. 13 025002), raising the possibility that changes to other stimulus parameters can similarly bias towards stronger ON responses. Here, we explore the effects of changing stimulus duration on the responses in ON and OFF types of brisk transient (BT) and brisk sustained (BS) RGCs. APPROACH We used cell-attached patch clamp to record RGC spiking in the isolated rabbit retina. Targeted RGCs were first classified as ON or OFF type by their light responses, and further sub-classified as BT or BS types by their responses to both light and electric stimuli. Spiking in targeted RGCs was recorded in response to electric pulses with durations varying from 5 to100 ms. Stimulus amplitude was adjusted at each duration to hold total charge constant for all experiments. MAIN RESULTS We found that varying stimulus durations modulated responses differentially for ON versus OFF cells: in ON cells, spike counts decreased significantly with increasing stimulus duration while in OFF cells the changes were more modest. The maximum ratio of ON versus OFF responses occurred at a duration of ~10 ms. The difference in response strength for BT versus BS cells was much larger in ON cells than in OFF cells. SIGNIFICANCE The stimulation rates preferred by subjects during clinical trials are similar to the rates that maximize the ON/OFF response ratio in in vitro testing (Im and Fried 2016a J. Neural Eng. 13 025002). Here, we determine the stimulus duration that produces the strongest bias towards ON responses and speculate that it will further enhance clinical effectiveness.
Collapse
|
33
|
Abstract
Wireless neural stimulators are being developed to address problems associated with traditional lead-based implants. However, designing wireless stimulators on the sub-millimeter scale (<1 mm3) is challenging. As device size shrinks, it becomes difficult to deliver sufficient wireless power to operate the device. Here, we present a sub-millimeter, inductively powered neural stimulator consisting only of a coil to receive power, a capacitor to tune the resonant frequency of the receiver, and a diode to rectify the radio-frequency signal to produce neural excitation. By replacing any complex receiver circuitry with a simple rectifier, we have reduced the required voltage levels that are needed to operate the device from 0.5 to 1 V (e.g., for CMOS) to ~0.25–0.5 V. This reduced voltage allows the use of smaller receive antennas for power, resulting in a device volume of 0.3–0.5 mm3. The device was encapsulated in epoxy, and successfully passed accelerated lifetime tests in 80°C saline for 2 weeks. We demonstrate a basic proof-of-concept using stimulation with tens of microamps of current delivered to the sciatic nerve in rat to produce a motor response.
Collapse
|
34
|
Implantable microcoils for intracortical magnetic stimulation. SCIENCE ADVANCES 2016; 2:e1600889. [PMID: 27957537 PMCID: PMC5148213 DOI: 10.1126/sciadv.1600889] [Citation(s) in RCA: 75] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Accepted: 11/03/2016] [Indexed: 05/20/2023]
Abstract
Neural prostheses that stimulate the neocortex have the potential to treat a wide range of neurological disorders. However, the efficacy of electrode-based implants remains limited, with persistent challenges that include an inability to create precise patterns of neural activity as well as difficulties in maintaining response consistency over time. These problems arise from fundamental limitations of electrodes as well as their susceptibility to implantation and have proven difficult to overcome. Magnetic stimulation can address many of these limitations, but coils small enough to be implanted into the cortex were not thought strong enough to activate neurons. We describe a new microcoil design and demonstrate its effectiveness for both activating cortical neurons and driving behavioral responses. The stimulation of cortical pyramidal neurons in brain slices in vitro was reliable and could be confined to spatially narrow regions (<60 μm). The spatially asymmetric fields arising from the coil helped to avoid the simultaneous activation of passing axons. In vivo implantation was safe and resulted in consistent and predictable behavioral responses. The high permeability of magnetic fields to biological substances may yield another important advantage because it suggests that encapsulation and other adverse effects of implantation will not diminish coil performance over time, as happens to electrodes. These findings suggest that a coil-based implant might be a useful alternative to existing electrode-based devices. The enhanced selectivity of microcoil-based magnetic stimulation will be especially useful for visual prostheses as well as for many brain-computer interface applications that require precise activation of the cortex.
Collapse
|
35
|
Enhanced Control of Cortical Pyramidal Neurons With Micromagnetic Stimulation. IEEE Trans Neural Syst Rehabil Eng 2016; 25:1375-1386. [PMID: 27893396 DOI: 10.1109/tnsre.2016.2631446] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
Abstract
Magnetic stimulation is less sensitive to the inflammatory reactions that plague conventional electrode-based cortical implants and therefore may be useful as a next-generation (implanted) cortical prosthetic. The fields arising from micro-coils are quite small however and thus, their ability to modulate cortical activity must first be established. Here, we show that layer V pyramidal neurons (PNs) can be strongly activated by micro-coil stimulation and further, the asymmetric fields arising from such coils do not simultaneously activate horizontally-oriented axon fibers, thus confining activation to a focal region around the coil. The spatially-narrow fields from micro-coils allowed the sensitivity of different regions within a single PN to be compared: while the proximal axon was most sensitive in naïve cells, repetitive stimulation over the apical dendrite led to a change in state of the neuron that reduced thresholds there to below those of the axon. Thus, our results raise the possibility that regardless of the mode of stimulation, penetration depths that target specific portions of the apical dendrite may actually be more effective than those that target Layer 6. Interestingly, the state change had similar properties to state changes described previously at the systems level, suggesting a possible neuronal mechanism underlying such responses.
Collapse
|
36
|
Directionally selective retinal ganglion cells suppress luminance responses during natural viewing. Sci Rep 2016; 6:35708. [PMID: 27759086 PMCID: PMC5069630 DOI: 10.1038/srep35708] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Accepted: 08/30/2016] [Indexed: 11/09/2022] Open
Abstract
The ON-OFF directionally selective cells of the retina respond preferentially to movement in a preferred direction, but under laboratory conditions they are also sensitive to changes in the luminance of the stationary stimulus. If the response of these neurons contains information about both direction and luminance downstream neurons are faced with the challenge of extracting the motion component, a computation that may be difficult under certain viewing conditions. Here, we show that during natural viewing the response to luminance is suppressed, leaving a relatively pure motion signal that gets transmitted to the brain.
Collapse
|
37
|
Temporal properties of network-mediated responses to repetitive stimuli are dependent upon retinal ganglion cell type. J Neural Eng 2016; 13:025002. [PMID: 26905231 DOI: 10.1088/1741-2560/13/2/025002] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE To provide artificially-elicited vision that is temporally dynamic, retinal prosthetic devices will need to repeatedly stimulate retinal neurons. However, given the diversity of physiological types of retinal ganglion cells (RGCs) as well as the heterogeneity of their responses to electric stimulation, temporal properties of RGC responses have not been adequately investigated. Here, we explored the cell type dependence of network-mediated RGC responses to repetitive electric stimulation at various stimulation rates. APPROACH We examined responses of ON and OFF types of RGCs in the rabbit retinal explant to five consecutive stimuli with varying inter-stimulus intervals (10-1000 ms). Each stimulus was a 4 ms long monophasic sinusoidal cathodal current, which was applied epiretinally via a conical electrode. Spiking activity of targeted RGCs was recorded using a cell-attached patch electrode. MAIN RESULTS ON and OFF cells had distinct responses to repetitive stimuli. Consistent with earlier studies, OFF cells always generated reduced responses to subsequent stimuli compared to responses to the first stimulus. In contrast, a new stimulus to ON cells suppressed all pending/ongoing responses from previous stimuli and initiated its own response that was remarkably similar to the response from a single stimulus in isolation. This previously unreported 'reset' behavior was observed exclusively and consistently in ON cells. These contrasts between ON and OFF cells created a range of stimulation rates (4-7 Hz) that maximized the ratio of the responses arising in ON versus OFF cells. SIGNIFICANCE Previous clinical testing reported that subjects perceive bright phosphenes (ON responses) and also prefer stimulation rates of 5-7 Hz. Our results suggest that responses of ON cells are weak at high rates of stimulation (> ∼7 Hz) due to the reset while responses of OFF cells are strong at low rates (< ∼4 Hz) due to reduced desensitization, both reducing the ratio of ON to OFF responses. In combination with previous results indicating that responses in ON cells more closely match physiological patterns (Im and Fried 2015 J. Physiol. 593 3577-96), our results offer a potential reason for the user preference of intermediate rates (5-7 Hz).
Collapse
|
38
|
The response of L5 pyramidal neurons of the PFC to magnetic stimulation from a micro-coil. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2014:6125-8. [PMID: 25571395 DOI: 10.1109/embc.2014.6945027] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Magnetic stimulation of the nervous system, e.g. transcranial magnetic stimulation (TMS), has been used both to unravel basic structure and function of the nervous system as well as to treat neurological diseases, i.e. clinical depression. Despite progress in both areas, ongoing advancements have been limited by a lack of understanding of the mechanism by which magnetic stimulation alters neural activity. Here, we report responses of cortical neurons to magnetic stimulation arising from a sub-millimeter coil. Cell attached patch clamp was used to record neural activity of layer 5/6 pyramidal neurons of the prefrontal cortex (PFC) in the in vitro mouse brain slice preparation. The fields arising from the small coil were quite different from those arising during clinical TMS but nevertheless allowed the responses of cortical neurons to magnetic stimulation to be probed. For example, the focal nature of induced fields allowed the sensitivity of different regions within targeted pyramidal neurons, e.g. apical dendrite, soma and axon hillock, to be compared. We found that PFC pyramidal neurons were not sensitive to single pulses of stimulation regardless of coil location. However, regions of the apical dendrite and proximal axon were both sensitive to repetitive stimulation as long as the orientation of the induced electric field was aligned with the long axis of the neuron. These results suggest that neurons of the PFC are sensitive to weak magnetic fields and further, that this type of approach may be useful for unraveling some of the mechanisms underlying TMS.
Collapse
|
39
|
Indirect activation elicits strong correlations between light and electrical responses in ON but not OFF retinal ganglion cells. J Physiol 2015; 593:3577-96. [PMID: 26033477 PMCID: PMC4560585 DOI: 10.1113/jp270606] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Accepted: 05/15/2015] [Indexed: 11/08/2022] Open
Abstract
KEY POINTS To improve the quality of vision elicited by retinal prosthetics, elicited neural activity should resemble physiological signalling patterns; here, we hypothesized that electric stimulation that activates the synaptic circuitry of the retina would lead to closer matches than that which activates ganglion cells directly. We evaluated this hypothesis by comparing light and electrical responses in different types of ganglion cells. In contrast to the similarity in their light responses, electrical responses in ON and OFF cells of the same type were quite distinct. Further, electrical and light responses in the same cell were much better correlated in ON vs. OFF ganglion cells. Stimuli that activated photoreceptors yielded better correlations than those which activated bipolar cells. Our results suggest that the closer match to physiology in the ON signal transmitted to the brain may help to explain preferential reports of 'bright' phosphenes during earlier clinical trials. ABSTRACT To improve the efficacy of microelectronic retinal prosthetics it will be necessary to better understand the response of retinal neurons to electric stimulation. While stimulation that directly activates ganglion cells generally has the lowest threshold, the similarity in responsiveness across cells makes it extremely difficult for such an approach to re-create cell-type specific patterns of neural activity that arise normally in the healthy retina. In contrast, stimulation that activates neurons presynaptic to ganglion cells utilizes at least some of the existing retinal circuitry and therefore is thought to produce neural activity that better matches physiological signalling. Surprisingly, the actual benefit(s) of this approach remain unsubstantiated. Here, we recorded from ganglion cells in the rabbit retinal explant in response to electrical stimuli that activated the network. Targeted cells were first classified into known types via light responses so that the consistency of electrical responses within individual types could be evaluated. Both transient and sustained ON ganglion cells exhibited highly consistent electrical response patterns which were distinct from one another. Further, properties of the response (interspike interval, latency, peak firing rate, and spike count) in a given cell were well correlated to the corresponding properties of the light response for that same cell. Electric responses in OFF ganglion cells formed two groups, distinct from ON groups, and the correlation levels between electric and light responses were much weaker. The closer match in ON pathway responses may help to explain some preferential reporting of bright stimuli during psychophysical testing.
Collapse
|
40
|
Abstract
Magnetic stimulation delivered via 0.5-mm diameter coils was recently shown to activate retinal neurons; the small coil size raises the possibility that micromagnetic stimulation ( μMS) could underlie a new generation of implanted neural prosthetics. Such an approach has several inherent advantages over conventional electric stimulation, including the potential for selective activation of neuronal targets as well as less susceptibility to inflammatory responses. The viability of μMS for some applications, e.g., deep brain stimulation (DBS), may require suppression (rather than creation) of neuronal activity, however, and therefore we explore here whether (μMS) could, in fact, suppress activity. While single pulses elicited weak and inconsistent spiking in neurons of the mouse subthalamic nucleus (in vitro), repetitive stimulation effectively suppressed activity in ∼ 70% of targeted neurons. This is the same percentage suppressed by conventional electric stimulation; with both modalities, suppression occurred only after an initial increase in spiking. The latency to the onset of suppression was inversely correlated to the energy of the stimulus waveform: larger amplitudes and lower frequencies had the fastest onset of suppression. These findings continue to support the viability of μMS as a next-generation implantable neural prosthetic.
Collapse
|
41
|
Influence of the sodium channel band on retinal ganglion cell excitation during electric stimulation--a modeling study. Neuroscience 2014; 266:162-77. [PMID: 24560986 PMCID: PMC4423397 DOI: 10.1016/j.neuroscience.2014.01.067] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2013] [Revised: 12/10/2013] [Accepted: 01/26/2014] [Indexed: 11/28/2022]
Abstract
Electric stimulation using retinal implants allows blind people to re-experience a rudimentary kind of vision. The elicited percepts or so called 'phosphenes' are highly inconstant and therefore do not restore vision properly. The better knowledge of how retinal neurons, especially retinal ganglion cells, respond to electric stimulation will help to develop more sophisticated stimulation strategies. Special anatomic and physiologic properties like a band of highly dense sodium channels in retinal ganglion cells may help to achieve a focal activation of target cells and as a result better restoration of vision. A portion of retinal ganglion cell axons, about 40μm from the soma and between 25 and 40μm in length, shows a specific biophysical property. Electrode locations close to a band of highly dense sodium channels which were identified immunochemically show lowest thresholds during electric stimulation. The (modeled) thresholds for this kind of structure result in lowest thresholds as well. The influence on the location where action potentials are generated within the axon is far reaching. When a stimulating electrode is positioned far outside the actual band region the site of spike initiation still remains within the sodium channel band. These findings suggest to further examine the key mechanisms of activation for retinal ganglion cells because focal activation without influencing passing axons of neurons located far away can improve the outcome of electric stimulation and therefore the development of retinal implants.
Collapse
|
42
|
Responses to pulsatile subretinal electric stimulation: effects of amplitude and duration. J Neurophysiol 2013; 109:1954-68. [PMID: 23343891 DOI: 10.1152/jn.00293.2012] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
In working to improve the quality of visual percepts elicited by retinal prosthetics, considerable effort has been made to understand how retinal neurons respond to electric stimulation. Whereas responses arising from direct activation of retinal ganglion cells have been well studied, responses arising through indirect activation (e.g., secondary to activation of bipolar cells) are not as well understood. Here, we used cell-attached, patch-clamp recordings to measure the responses of rabbit ganglion cells in vitro to a wide range of stimulus-pulse parameters (amplitudes: 0-100 μA; durations: 0.1-50 ms), applied to a 400-μm-diameter, subretinal-stimulating electrode. The indirect responses generally consisted of multiple action potentials that were clustered into bursts, although the latency and number of spikes within a burst were highly variable. When different parameter pairs representing identical charge levels were compared, the shortest pulse durations generally elicited the most spikes. In addition, latencies were shortest, and jitter was lowest for short pulses. These findings suggest that short pulses are optimum for activation of presynaptic neurons, and therefore, short pulses are more effective for both direct as well as indirect activation.
Collapse
|
43
|
Abstract
Electrical stimulation is currently used to treat a wide range of cardiovascular, sensory and neurological diseases. Despite its success, there are significant limitations to its application, including incompatibility with magnetic resonance imaging, limited control of electric fields and decreased performance associated with tissue inflammation. Magnetic stimulation overcomes these limitations but existing devices (that is, transcranial magnetic stimulation) are large, reducing their translation to chronic applications. In addition, existing devices are not effective for deeper, sub-cortical targets. Here we demonstrate that sub-millimeter coils can activate neuronal tissue. Interestingly, the results of both modelling and physiological experiments suggest that different spatial orientations of the coils relative to the neuronal tissue can be used to generate specific neural responses. These results raise the possibility that micro-magnetic stimulation coils, small enough to be implanted within the brain parenchyma, may prove to be an effective alternative to existing stimulation devices. Electrical stimulation is used to treat a range of neurological diseases, but there are limitations that reduce its benefits. Bonmassar and colleagues show that magnetic stimulation delivered by small coils, close to the targeted neural tissue, can also be used to activate neurons and with fewer limitations.
Collapse
|
44
|
High frequency electric stimulation of retinal neurons elicits physiological signaling patterns. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2011:1077-80. [PMID: 22254500 DOI: 10.1109/iembs.2011.6090251] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The effectiveness of retinal prosthetics will depend on their ability to elicit patterns of neural activity that can be recognized by the visual cortex. While conventional short-duration pulses activate retinal neurons effectively, many nearby neurons are thought to respond similarly to a given pulse train--a situation that is non-physiological. Use of pulse trains delivered at rates > 1000 pulses per second (PPS) in cochlear prosthetics help to avoid phase-locked responses but have not been evaluated in the retina; here, we explored the response to trains of 2000 PPS. We found that ganglion cells respond robustly to these stimuli but that the properties of the response were highly sensitive to stimulus amplitude. At low amplitudes the response patterns were burst-like while at higher amplitudes elicited spikes had intervals that were more uniform. Because burst responses were insensitive to synaptic blockers, our results suggest that they arise from direct activation. This was surprising because previous studies indicated that burst responses arise only through indirect activation. Thus, our results suggest multiple mechanisms of burst creation may exist. Further, histograms of interspike intervals revealed that the response properties were different in different types of ganglion cells. While further testing is needed, the ability to create different patterns of activity in different types of ganglion cells raises the possibility that more natural spike patterns can be created.
Collapse
|
45
|
Calcium channel dynamics limit synaptic release in response to prosthetic stimulation with sinusoidal waveforms. J Neural Eng 2011; 8:046005. [PMID: 21628768 PMCID: PMC3152377 DOI: 10.1088/1741-2560/8/4/046005] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Extracellular electric stimulation with sinusoidal waveforms has been shown to allow preferential activation of individual types of retinal neurons by varying stimulus frequency. It is important to understand the mechanisms underlying this frequency dependence as a step toward improving methods of preferential activation. In order to elucidate these mechanisms, we implemented a morphologically realistic model of a retinal bipolar cell and measured the response to extracellular stimulation with sinusoidal waveforms. We compared the frequency response of a passive membrane model to the kinetics of voltage-gated calcium channels that mediate synaptic release. The passive electrical properties of the membrane exhibited lowpass filtering with a relatively high cutoff frequency (nominal value = 717 Hz). This cutoff frequency was dependent on intra-axonal resistance, with shorter and wider axons yielding higher cutoff frequencies. However, we found that the cutoff frequency of bipolar cell synaptic release was primarily limited by the relatively slow opening kinetics of L- and T-type calcium channels. The cutoff frequency of calcium currents depended nonlinearly on stimulus amplitude, but remained lower than the cutoff frequency of the passive membrane model for a large range of membrane potential fluctuations. These results suggest that while it may be possible to modulate the membrane potential of bipolar cells over a wide range of stimulus frequencies, synaptic release will only be initiated at the lower end of this range.
Collapse
|
46
|
Response variability to high rates of electric stimulation in retinal ganglion cells. J Neurophysiol 2011; 106:153-62. [PMID: 21490287 PMCID: PMC3295376 DOI: 10.1152/jn.00956.2010] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2010] [Accepted: 04/05/2011] [Indexed: 11/22/2022] Open
Abstract
To improve the quality of prosthetic vision, it is important to understand how retinal neurons respond to electric stimulation. Previous studies present conflicting reports as to the maximum rate at which retinal ganglion cells can "follow" pulse trains, i.e., generate one spike for each pulse of the train. In the present study, we measured the response of 5 different types of rabbit retinal ganglion cells to pulse trains of 100-700 Hz. Surprisingly, we found significant heterogeneity in the ability of different types to follow pulse trains. For example, brisk transient (BT) ganglion cells could reliably follow pulse rates up to 600 pulses per second (PPS). In contrast, other types could not even follow rates of 200 PPS. There was additional heterogeneity in the response patterns across those types that could not follow high-rate trains. For example, some types generated action potentials in response to approximately every other pulse, whereas other types generated one spike per pulse for a few consecutive pulses and then did not generate any spikes in response to the next few pulses. Interestingly, in the types that could not follow high-rate trains, we found a second type of response: many pulses of the train elicited a biphasic waveform with an amplitude much smaller than that of standard action potentials. This small waveform was often observed following every pulse for which a standard spike was not elicited. A possible origin of the small waveform and its implication for effective retinal stimulation are discussed.
Collapse
|
47
|
Abstract
Retinal prostheses aim to restore functional vision to those blinded by outer retinal diseases using electric stimulation of surviving retinal neurons. The ability to replicate the spatiotemporal pattern of ganglion cell spike trains present under normal viewing conditions is presumably an important factor for restoring high-quality vision. In order to replicate such activity with a retinal prosthesis, it is important to consider both how visual information is encoded in ganglion cell spike trains, and how retinal neurons respond to electric stimulation. The goal of the current review is to bring together these two concepts in order to guide the development of more effective stimulation strategies. We review the experiments to date that have studied how retinal neurons respond to electric stimulation and discuss these findings in the context of known retinal signaling strategies. The results from such in vitro studies reveal the advantages and disadvantages of activating the ganglion cell directly with the electric stimulus (direct activation) as compared to activation of neurons that are presynaptic to the ganglion cell (indirect activation). While direct activation allows high temporal but low spatial resolution, indirect activation yields improved spatial resolution but poor temporal resolution. Finally, we use knowledge gained from in vitro experiments to infer the patterns of elicited activity in ongoing human trials, providing insights into some of the factors limiting the quality of prosthetic vision.
Collapse
|
48
|
Abstract
To improve the quality of prosthetic vision, it is desirable to understand how targeted retinal neurons respond to stimulation. Unfortunately, the factors that shape the response of a single neuron to stimulation are not well understood. A dense band of voltage-gated sodium channels within the proximal axon of retinal ganglion cells is the site most sensitive to electric stimulation, suggesting that band properties are likely to influence the response to stimulation. Here, we examined how three band properties influence sensitivity using a morphologically realistic ganglion cell model in NEURON. Longer bands were more sensitive to short-duration pulses than shorter bands and increasing the distance between band and soma also increased sensitivity. Simulations using the known limits of band length and location resulted in a sensitivity difference of approximately 2. Additional simulations tested how changes to sodium channel conductance within the band influenced threshold and found that the sensitivity difference increased to a factor of nearly 3. This is close to the factor of 5 difference measured in physiological studies suggesting that band properties contribute significantly to the sensitivity differences found between different types of retinal neurons.
Collapse
|
49
|
Abstract
Retinal prostheses aim to restore functional vision to those blinded by outer retinal diseases using electric stimulation of surviving neurons. Previous work indicates that repetitive stimulation with stimuli that activate the synaptic network reduces the sensitivity of retinal neurons to further stimulation. Such desensitization may contribute to the fading of visual percepts over time reported by human subjects. Here, we show that desensitization may be more complex than previously considered. We recorded spike trains from rabbit retinal ganglion cells and found that desensitization persists in the presence of inhibitory blockers (strychnine and picrotoxin), indicating amacrine cell inhibition is not solely responsible for reducing sensitivity in response to electric stimulation. The threshold for direct activation of the ganglion cell changes little during the simultaneous desensitization of the synaptically mediated response, indicating that desensitization likely occurs upstream of the spike generator. In addition to rapid desensitization acting over hundreds of milliseconds (τ = 176.4 ± 8.8 ms), we report the presence of slow acting desensitization with a time course of seconds (τ = 14.0 ± 1.1 s). The time courses of the two components of desensitization that we found are similar to the two phases of brightness fading seen in human subjects. This suggests that the reduction in ganglion cell firing due to desensitization may be responsible for the fading of visual percepts over time in response to prosthetic stimulation.
Collapse
|
50
|
Selective activation of neuronal targets with sinusoidal electric stimulation. J Neurophysiol 2010; 104:2778-91. [PMID: 20810683 PMCID: PMC2997038 DOI: 10.1152/jn.00551.2010] [Citation(s) in RCA: 110] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2010] [Accepted: 08/31/2010] [Indexed: 11/22/2022] Open
Abstract
Electric stimulation of the CNS is being evaluated as a treatment modality for a variety of neurological, psychiatric, and sensory disorders. Despite considerable success in some applications, existing stimulation techniques offer little control over which cell types or neuronal substructures are activated by stimulation. The ability to more precisely control neuronal activation would likely improve the clinical outcomes associated with these applications. Here, we show that specific frequencies of sinusoidal stimulation can be used to preferentially activate certain retinal cell types: photoreceptors are activated at 5 Hz, bipolar cells at 25 Hz, and ganglion cells at 100 Hz. In addition, low-frequency stimulation (≤25 Hz) did not activate passing axons but still elicited robust synaptically mediated responses in ganglion cells; therefore, elicited neural activity is confined to within a focal region around the stimulating electrode. Our results suggest that sinusoidal stimulation provides significantly improved control over elicited neural activity relative to conventional pulsatile stimulation.
Collapse
|