1
|
Probability of normal tissue complications for hematologic and gastrointestinal toxicity in postoperative whole pelvic radiotherapy for gynecologic malignancies using intensity-modulated proton therapy with robust optimization. JOURNAL OF RADIATION RESEARCH 2024; 65:369-378. [PMID: 38499489 PMCID: PMC11115445 DOI: 10.1093/jrr/rrae008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 12/26/2023] [Indexed: 03/20/2024]
Abstract
This retrospective treatment-planning study was conducted to determine whether intensity-modulated proton therapy with robust optimization (ro-IMPT) reduces the risk of acute hematologic toxicity (H-T) and acute and late gastrointestinal toxicity (GI-T) in postoperative whole pelvic radiotherapy for gynecologic malignancies when compared with three-dimensional conformal radiation therapy (3D-CRT), intensity-modulated X-ray (IMXT) and single-field optimization proton beam (SFO-PBT) therapies. All plans were created for 13 gynecologic-malignancy patients. The prescribed dose was 45 GyE in 25 fractions for 95% planning target volume in 3D-CRT, IMXT and SFO-PBT plans and for 99% clinical target volume (CTV) in ro-IMPT plans. The normal tissue complication probability (NTCP) of each toxicity was used as an in silico surrogate marker. Median estimated NTCP values for acute H-T and acute and late GI-T were 0.20, 0.94 and 0.58 × 10-1 in 3D-CRT; 0.19, 0.65 and 0.24 × 10-1 in IMXT; 0.04, 0.74 and 0.19 × 10-1 in SFO-PBT; and 0.06, 0.66 and 0.15 × 10-1 in ro-IMPT, respectively. Compared with 3D-CRT and IMXT plans, the ro-IMPT plan demonstrated significant reduction in acute H-T and late GI-T. The risk of acute GI-T in ro-IMPT plan is equivalent with IMXT plan. The ro-IMPT plan demonstrated potential clinical benefits for reducing the risk of acute H-T and late GI-T in the treatment of gynecologic malignances by reducing the dose to the bone marrow and bowel bag while maintaining adequate dose coverage to the CTV. Our results indicated that ro-IMPT may reduce acute H-T and late GI-T risk with potentially improving outcomes for postoperative gynecologic-malignancy patients with concurrent chemotherapy.
Collapse
|
2
|
A Single-Institution Prospective Study To Evaluate the Safety and Efficacy of Real- Time Image-Gated Spot-Scanning Proton Therapy (RGPT) for Prostate Cancer. Adv Radiat Oncol 2024; 9:101464. [PMID: 38560429 PMCID: PMC10981019 DOI: 10.1016/j.adro.2024.101464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Accepted: 01/30/2024] [Indexed: 04/04/2024] Open
Abstract
Purpose In real-time image-gated spot-scanning proton therapy (RGPT), the dose distribution is distorted by gold fiducial markers placed in the prostate. Distortion can be suppressed by using small markers and more than 2 fields, but additional fields may increase the dose to organs at risk. Therefore, we conducted a prospective study to evaluate the safety and short-term clinical outcome of RGPT for prostate cancer. Methods and Materials Based on the previously reported frequency of early adverse events (AE) and the noninferiority margin of 10%, the required number of cases was calculated to be 43 using the one-sample binomial test by the Southwest Oncology Group statistical tools with the one-sided significance level of 2.5% and the power 80%. Patients with localized prostate cancer were enrolled and 3 to 4 pure gold fiducial markers of 1.5-mm diameter were inserted in the prostate. The prescribed dose was 70 Gy(relative biologic effectiveness) in 30 fractions, and treatment was performed with 3 fields from the left, right, and the back, or 4 fields from either side of slightly anterior and posterior oblique fields. The primary endpoint was the frequency of early AE (≥grade 2) and the secondary endpoint was the biochemical relapse-free survival rate and the frequency of late AE. Results Forty-five cases were enrolled between 2015 and 2017, and all patients completed the treatment protocol. The median follow-up period was 63.0 months. The frequency of early AE (≥grade 2) was observed in 4 cases (8.9%), therefore the noninferiority was verified. The overall 5-year biochemical relapse-free survival rate was 88.9%. As late AE, grade 2 rectal bleeding was observed in 8 cases (17.8%). Conclusions The RGPT for prostate cancer with 1.5-mm markers and 3- or 4- fields was as safe as conventional proton therapy in early AE, and its efficacy was comparable with previous studies.
Collapse
|
3
|
Technical note: Application of an optical hydrophone to ionoacoustic range detection in a tissue-mimicking agar phantom. Med Phys 2023. [PMID: 38127935 DOI: 10.1002/mp.16892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 11/07/2023] [Accepted: 11/29/2023] [Indexed: 12/23/2023] Open
Abstract
BACKGROUND Ionoacoustics is a promising approach to reduce the range uncertainty in proton therapy. A miniature-sized optical hydrophone (OH) was used as a measuring device to detect weak ionoacoustic signals with a high signal-to-noise ratio in water. However, further development is necessary to prevent wave distortion because of nearby acoustic impedance discontinuities while detection is conducted on the patient's skin. PURPOSE A prototype of the probe head attached to an OH was fabricated and the required dimensions were experimentally investigated using a 100-MeV proton beam from a fixed-field alternating gradient accelerator and k-Wave simulations. The beam range of the proton in a tissue-mimicking phantom was estimated by measuring γ-waves and spherical ionoacoustic waves with resonant frequency (SPIRE). METHODS Four sizes of probe heads were fabricated from agar blocks for the OH. Using the prototype, the γ-wave was detected at distal and lateral positions to the Bragg peak on the phantom surface for proton beams delivered at seven positions. For SPIRE, independent measurements were performed at distal on- and off-axis positions. The range positions were estimated by solving the linear equation using the sensitive matrix for the γ-wave and linear fitting of the correlation curve for SPIRE; they were compared with those measured using a film. RESULTS The first peak of the γ-wave was undistorted with the 3 × 3 × 3-cm3 probe head used at the on-axis and 3-cm off-axis positions. The range positions estimated by the γ-wave agreed with the film-based range in the depth direction (the maximum deviation was 0.7 mm), although a 0.6-2.1 mm deviation was observed in the lateral direction. For SPIRE, the deviation was <1 mm for the two measurement positions. CONCLUSIONS The attachment of a relatively small-sized probe head allowed the OH to measure the beam range on the phantom surface.
Collapse
|
4
|
Evaluation of the Possibility of Dose Realignment Adaptation by Shifting the Isocenter in Proton Beam Therapy for Pancreatic Cancer. Int J Radiat Oncol Biol Phys 2023; 117:e307. [PMID: 37785114 DOI: 10.1016/j.ijrobp.2023.06.2330] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
PURPOSE/OBJECTIVE(S) In pancreatic cancer, a tumor is surrounded by the gastrointestinal (GI) tract, which is subject to changes in location, shape, and contents. Due to these inter-fractional changes, proton beam therapy (PBT) for pancreatic cancer may result in unintentionally high doses to the GI tract. Daily adaptive re-planning can solve this problem, but is not yet established with PBT due to its resource intensive characteristics. This study aims to evaluate the GI tract dose using weekly computed tomography (CTw) and the possibility of dose realignment adaptation by shifting the isocenter (IC) of the PBT plan, which does not require re-planning. MATERIALS/METHODS We retrospectively analyzed 6 consecutive patients with unresectable pancreatic cancer treated with real-time-image gated PBT using a fiducial marker. The planning CT was scanned at the natural expiration of respiration and a PBT plan of 60 GyE in 25 fractions (baseline plan, PLANbase) was created. The CTw images were acquired the day before start of PBT and once a week during the PBT course thereafter. The PLANbase was rigidly transferred to the CTw based on the relationship between the three-dimensional coordinates of the fiducial marker and those of the IC in the PLANbase. The PLANeval was created by recalculating the PLANbase on the CTw. We evaluated the doses to the stomach, duodenum, and intestines in the PLANeval according to the following criteria: Dmax of the stomach < 60 GyE, duodenum and intestines < 55 GyE, and D1cc of the stomach < 55 GyE, duodenum and intestines < 54 GyE. In addition, we investigated the GI tract dose realignment adaptation for the PLANeval with its IC shifted 2mm, 4mm, and 6mm in each of 6 directions (right, left, ventral, dorsal, cranial, and caudal), respectively. RESULTS A total of 35 PLANeval were created for the CTw. In the PLANbase of the 6 patients, the average of Dmax and D1cc of the stomach, duodenum and intestines were 50.7 GyE (range, 46.7-53.6) and 50.0 GyE (45.0-53.2), 49.2 GyE (44.3-51.7) and 48.8 GyE (43.7-51.5), and 49.2 GyE (44.8-52.0) and 48.9 GyE (44.6-51.8), respectively. In the PLANeval, the average of Dmax and D1cc of the stomach, duodenum, and intestines were 53.3GyE (43.8-61.4) and 52.8 GyE (43.2-61.1), 51.0 GyE (36.1-60.0) and 50.3 GyE (35.4-59.8), and 52.5 GyE (36.6-61.0) and 51.9 (34.4-60.9) GyE, respectively. Twenty-two of the 35 PLANeval (63 %) did not meet at least one of the GI tract dose criteria. In 11 of 22 PLANeval with higher doses to the GI tract, the IC shift resulted in GI dose reductions and all dose criteria were met. The minimum amount of the IC shift required to meet the criteria was 2 mm for 8 plans and 4 mm for 3 plans. The remaining 11 PLANeval did not meet the criteria using dose realignment adaptation by shifting the isocenter. CONCLUSION Adaptive replanning is necessary for PBT for pancreatic cancers due to excessive GI tract doses in more than 60% of the plans. Dose realignment adaptation by shifting the IC, which does not require re-planning, may be an option in adaptive treatment strategies.
Collapse
|
5
|
On performance and anti-fouling properties of double-skinned thin film nanocomposite hollow fiber membranes in forward osmosis system. Chem Eng Res Des 2023. [DOI: 10.1016/j.cherd.2023.03.048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/31/2023]
|
6
|
Study of hepatic toxicity in small liver tumors after photon or proton therapy based on factors predicting the benefits of proton. Br J Radiol 2023; 96:20220720. [PMID: 36633335 PMCID: PMC10078862 DOI: 10.1259/bjr.20220720] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 11/29/2022] [Accepted: 12/12/2022] [Indexed: 01/13/2023] Open
Abstract
OBJECTIVES In a previous study of hepatic toxicity, the following three factors were identified to predict the benefits of proton beam therapy (PBT) for hepatocellular carcinomas (HCCs) with a maximum diameter of ≤5 cm and Child-pugh grade A (CP-A): number of tumors (1 vs ≥2), the location of tumors (hepatic hilum or others), and the sum of the diameters of lesions. The aim of this study is to analyze the association between these three factors and hepatic toxicity. METHODS We retrospectively reviewed patients of CP-A treated with PBT or photon stereotactic body radiotherapy (X-ray radiotherapy, XRT) for HCC ≤5 cm. For normal liver dose, the V5, V10, V20 (volumes receiving 5, 10, and 20 Gy at least), and the mean dose was evaluated. The albumin-bilirubin (ALBI) and CP score changes from the baseline were evaluated at 3 and 6 months after treatment. RESULTS In 89 patients (XRT: 48, PBT: 41), those with two or three (2-3) predictive factors were higher normal liver doses than with zero or one (0-1) factor. In the PBT group, the ALBI score worsened more in patients with 2-3 factors than those with 0-1 factor, at 3 months (median: 0.26 vs 0.02, p = 0.032) and at 6 months (median: 0.35 vs 0.10, p = 0.009). The ALBI score change in the XRT group and CP score change in either modality were not significantly different in the number of predictive factors. CONCLUSION The predictive factor numbers predicted the ALBI score change in PBT but not in XRT. ADVANCES IN KNOWLEDGE This study suggest that the number of predictive factors previously identified (0-1 vs 2-3) were significantly associated with dosimetric parameters of the normal liver in both modalities. In the proton group, the number of predictive factors was associated with a worsening ALBI score at 3 and 6 months, but these associations were not found in the photon SBRT group.
Collapse
|
7
|
Genomic features of renal cell carcinoma developed during end-stage renal disease and dialysis. Eur Urol 2023. [DOI: 10.1016/s0302-2838(23)01082-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
|
8
|
Technical note: Performance evaluation of volumetric imaging based on motion modeling by principal component analysis. Med Phys 2023; 50:993-999. [PMID: 36427355 DOI: 10.1002/mp.16123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Revised: 10/17/2022] [Accepted: 11/20/2022] [Indexed: 11/27/2022] Open
Abstract
PURPOSE To quantitatively evaluate the achievable performance of volumetric imaging based on lung motion modeling by principal component analysis (PCA). METHODS In volumetric imaging based on PCA, internal deformation was represented as a linear combination of the eigenvectors derived by PCA of the deformation vector fields evaluated from patient-specific four-dimensional-computed tomography (4DCT) datasets. The volumetric image was synthesized by warping the reference CT image with a deformation vector field which was evaluated using optimal principal component coefficients (PCs). Larger PCs were hypothesized to reproduce deformations larger than those included in the original 4DCT dataset. To evaluate the reproducibility of PCA-reconstructed volumetric images synthesized to be close to the ground truth as possible, mean absolute error (MAE), structure similarity index measure (SSIM) and discrepancy of diaphragm position were evaluated using 22 4DCT datasets of nine patients. RESULTS Mean MAE and SSIM values for the PCA-reconstructed volumetric images were approximately 80 HU and 0.88, respectively, regardless of the respiratory phase. In most test cases including the data of which motion range was exceeding that of the modeling data, the positional error of diaphragm was less than 5 mm. The results suggested that large deformations not included in the modeling 4DCT dataset could be reproduced. Furthermore, since the first PC correlated with the displacement of the diaphragm position, the first eigenvector became the dominant factor representing the respiration-associated deformations. However, other PCs did not necessarily change with the same trend as the first PC, and no correlation was observed between the coefficients. Hence, randomly allocating or sampling these PCs in expanded ranges may be applicable to reasonably generate an augmented dataset with various deformations. CONCLUSIONS Reasonable accuracy of image synthesis comparable to those in the previous research were shown by using clinical data. These results indicate the potential of PCA-based volumetric imaging for clinical applications.
Collapse
|
9
|
Deformed dose restoration to account for tumor deformation and position changes for adaptive proton therapy. Med Phys 2023; 50:675-687. [PMID: 36502527 DOI: 10.1002/mp.16149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 11/10/2022] [Accepted: 11/25/2022] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Online adaptation during intensity-modulated proton therapy (IMPT) can minimize the effect of inter-fractional anatomical changes, but remains challenging because of the complex workflow. One approach for fast and automated online IMPT adaptation is dose restoration, which restores the initial dose distribution on the updated anatomy. However, this method may fail in cases where tumor deformation or position changes occur. PURPOSE To develop a fast and robust IMPT online adaptation method named "deformed dose restoration (DDR)" that can adjust for inter-fractional tumor deformation and position changes. METHODS The DDR method comprises two steps: (1) calculation of the deformed dose distribution, and (2) restoration of the deformed dose distribution. First, the deformable image registration (DIR) between the initial clinical target volume (CTV) and the new CTV were performed to calculate the vector field. To ensure robustness for setup and range uncertainty and the ability to restore the deformed dose distribution, an expanded CTV-based registration to maintain the dose gradient outside the CTV was developed. The deformed dose distribution was obtained by applying the vector field to the initial dose distribution. Then, the voxel-by-voxel dose difference optimization was performed to calculate beam parameters that restore the deformed dose distribution on the updated anatomy. The optimization function was the sum of total dose differences and dose differences of each field to restore the initial dose overlap of each field. This method only requires target contouring, which eliminates the need for organs at risk (OARs) contouring. Six clinical cases wherein the tumor deformation and/or position changed on repeated CTs were selected. DDR feasibility was evaluated by comparing the results with those from three other strategies, namely, not adapted (continuing the initial plan), adapted by previous dose restoration, and fully optimized. RESULTS In all cases, continuing the initial plan was largely distorted on the repeated CTs and the dose-volume histogram (DVH) metrics for the target were reduced due to the tumor deformation or position changes. On the other hand, DDR improved DVH metrics for the target to the same level as the initial dose distribution. Dose increase was seen for some OARs because tumor growth had reduced the relative distance between CTVs and OARs. Robustness evaluation for setup and range uncertainty (3 mm/3.5%) showed that deviation in DVH-bandwidth for CTV D95% from the initial plan was 0.4% ± 0.5% (Mean ± S.D.) for DDR. The calculation time was 8.1 ± 6.4 min. CONCLUSIONS An online adaptation algorithm was developed that improved the treatment quality for inter-fractional anatomical changes and retained robustness for intra-fractional setup and range uncertainty. The main advantage of this method is that it only requires target contouring alone and saves the time for OARs contouring. The fast and robust adaptation method for tumor deformation and position changes described here can reduce the need for offline adaptation and improve treatment efficiency.
Collapse
|
10
|
Ionoacoustic application of an optical hydrophone to detect proton beam range in water. Med Phys 2022; 50:2438-2449. [PMID: 36565440 DOI: 10.1002/mp.16189] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 11/22/2022] [Accepted: 12/14/2022] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND Proton range uncertainty has been the main factor limiting the ability of proton therapy to concentrate doses to tumors to their full potential. Ionoacoustic (IA) range verification is an approach to reducing this uncertainty by detecting thermoacoustic waves emitted from an irradiated volume immediately following a pulsed proton beam delivery; however, the signal weakness has been an obstacle to its clinical application. To increase the signal-to-noise ratio (SNR) with the conventional piezoelectric hydrophone (PH), the detector-sensitive volume needs to be large, but it could narrow the range of available beam angles and disturb real-time images obtained during beam delivery. PURPOSE To prevent this issue, we investigated a millimeter-sized optical hydrophone (OH) that exploits the laser interferometric principle. For two types of IA waves [γ-wave emitted from the Bragg peak (BP) and a spherical IA wave with resonant frequency (SPIRE) emitted from the gold fiducial marker (GM)], comparisons were made with PH in terms of waveforms, SNR, range detection accuracy, and signal intensity robustness against the small detector misalignment, particularly for SPIRE. METHODS A 100-MeV proton beam with a 27 ns pulse width and 4 mm beam size was produced using a fixed-field alternating gradient accelerator and was irradiated to the water phantom. The GM was set on the beam's central axis. Acrylic plates of various thicknesses, up to 12 mm, were set in front of the phantoms to shift the proton range. OH was set distal and lateral to the beam, and the range was estimated using the time-of-flight method for γ-wave and by comparing with the calibration data (SPIRE intensity versus the distance between the GM and BP) derived from an IA wave transport simulation for SPIRE. The BP dose per pulse was 0.5-0.6 Gy. To measure the variation in SPIRE amplitude against the hydrophone misalignment, the hydrophone was shifted by ± 2 mm at a maximum in lateral directions. RESULTS Despite its small size, OH could detect γ-wave with a higher SNR than the conventional PH (diameter, 29 mm), and a single measurement was sufficient to detect the beam range with a submillimeter accuracy in water. In the SPIRE measurement, OH was far more robust against the detector misalignment than the focused PH (FPH) used in our previous study [5%/mm (OH) versus 80%/mm (FPH)], and the correlation between the measured SPIRE intensity and the distance between the GM and BP agreed well with the simulation results. However, the OH sensitivity was lower than the FPH sensitivity, and about 5.6-Gy dose was required to decrease the intensity variation among measurements to less than 10%. CONCLUSION The miniature OH was found to detect weak IA signals produced by proton beams with a BP dose used in hypofractionated regimens. The OH sensitivity improvement at the MHz regime is worth exploring as the next step.
Collapse
|
11
|
Hyperfractionated intensity-modulated proton therapy for pharyngeal cancer with variable relative biological effectiveness: A simulation study. Med Phys 2022; 49:7815-7825. [PMID: 36300598 DOI: 10.1002/mp.16064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 10/06/2022] [Accepted: 10/07/2022] [Indexed: 12/27/2022] Open
Abstract
BACKGROUND The relative biological effectiveness (RBE) of proton is considered to be dependent on biological parameters and fractional dose. While hyperfractionated photon therapy was effective in the treatment of patients with head and neck cancers, its effect in intensity-modulated proton therapy (IMPT) under the variable RBE has not been investigated in detail. PURPOSE To study the effect of variable RBE on hyperfractionated IMPT for the treatment of pharyngeal cancer. We investigated the biologically effective dose (BED) to determine the theoretical effective hyperfractionated schedule. METHODS The treatment plans of three pharyngeal cancer patients were used to define the ΔBED for the clinical target volume (CTV) and soft tissue (acute and late reaction) as the difference between the BED for the altered schedule with variable RBE and conventional schedule with constant RBE. The ΔBED with several combinations of parameters (treatment days, number of fractions, and prescribed dose) was comprehensively calculated. Of the candidate schedules, the one that commonly gave a higher ΔBED for CTV was selected as the resultant schedule. The BED volume histogram was used to compare the influence of variable RBE and fractionation. RESULTS In the conventional schedule, compared with the constant RBE, the variable RBE resulted in a mean 2.6 and 2.7 Gy reduction of BEDmean for the CTV and soft tissue (acute reaction) of the three plans, respectively. Moreover, the BEDmean for soft tissue (late reaction) increased by 7.4 Gy, indicating a potential risk of increased RBE. Comprehensive calculation of the ΔBED resulted in the hyperfractionated schedule of 80.52 Gy (RBE = 1.1)/66 fractions in 6.5 weeks. When variable RBE was used, compared with the conventional schedule, the hyperfractionated schedule increased the BEDmean for CTV by 7.6 Gy; however, this was associated with a 7.8 Gy increase for soft tissue (acute reaction). The BEDmean for soft tissue (late reaction) decreased by 2.4 Gy. CONCLUSION The results indicated a potential effect of the variable RBE on IMPT for pharyngeal cancer but with the possibility that hyperfractionation could outweigh this effect. Although biological uncertainties require conservative use of the resultant schedule, hyperfractionation is expected to be an effective strategy in IMPT for pharyngeal cancer.
Collapse
|
12
|
A study on predicting cases that would benefit from proton beam therapy in primary liver tumors of less than or equal to 5 cm based on the estimated incidence of hepatic toxicity. Clin Transl Radiat Oncol 2022; 35:70-75. [PMID: 35633653 PMCID: PMC9130086 DOI: 10.1016/j.ctro.2022.05.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 05/02/2022] [Accepted: 05/13/2022] [Indexed: 11/25/2022] Open
Abstract
An advantage of PBT is reducing the liver receiving low doses of radiation. The factors predicting the benefit in PBT are different among NTCP models. The tumor size, number, and location are useful in estimating the benefits of PBT.
Background Materials and methods Results Conclusions
Collapse
|
13
|
An initial systematic study of the linear energy transfer distributions of a proton beam under a transverse magnetic field. Med Phys 2022; 49:1839-1852. [DOI: 10.1002/mp.15478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 01/11/2022] [Accepted: 01/12/2022] [Indexed: 11/10/2022] Open
|
14
|
Impact of a spatially dependent dose delivery time structure on the biological effectiveness of scanning proton therapy. Med Phys 2021; 49:702-713. [PMID: 34796522 DOI: 10.1002/mp.15367] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2021] [Revised: 10/09/2021] [Accepted: 11/02/2021] [Indexed: 11/09/2022] Open
Abstract
PURPOSE In the scanning beam delivery of protons, different portions of the target are irradiated with different linear energy transfer protons with various time intervals and irradiation times. This research aimed to evaluate the spatially dependent biological effectiveness of protracted irradiation in scanning proton therapy. METHODS One and two parallel opposed fields plans were created in water phantom with the prescribed dose of 2 Gy. Three scenarios (instantaneous, continuous, and layered scans) were used with the corresponding beam delivery models. The biological dose (physical dose × relative biological effectiveness) was calculated using the linear quadratic model and the theory of dual radiation action to quantitatively evaluate the dose delivery time effect. In addition, simulations using clinical plans (postoperative seminoma and prostate tumor cases) were conducted to assess the impact of the effects on the dose volume histogram parameters and homogeneity coefficient (HC) in targets. RESULTS In a single-field plan of water phantom, when the treatment time was 19 min, the layered-scan scenario showed a decrease of <0.2% (almost 3.3%) in the biological dose from the plan on the distal (proximal) side because of the high (low) dose rate. This is in contrast to the continuous scenario, where the biological dose was almost uniformly decreased over the target by approximately 3.3%. The simulation with clinical geometry showed that the decrease rates in D99% were 0.9% and 1.5% for every 10 min of treatment time prolongation for postoperative seminoma and prostate tumor cases, respectively, whereas the increase rates in HC were 0.7% and 0.2%. CONCLUSIONS In protracted irradiation in scanning proton therapy, the spatially dependent dose delivery time structure in scanning beam delivery can be an important factor for accurate evaluation of biological effectiveness.
Collapse
|
15
|
Particle therapy using protons or carbon ions for cancer patients with cardiac implantable electronic devices (CIED): a retrospective multi-institutional study. Jpn J Radiol 2021; 40:525-533. [PMID: 34779984 PMCID: PMC9068656 DOI: 10.1007/s11604-021-01218-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Accepted: 11/05/2021] [Indexed: 11/27/2022]
Abstract
PURPOSE To evaluate the outcomes of particle therapy in cancer patients with cardiac implantable electronic devices (CIEDs). MATERIALS AND METHODS From April 2001 to March 2013, 19,585 patients were treated with proton beam therapy (PBT) or carbon ion therapy (CIT) at 8 institutions. Of these, 69 patients (0.4%, PBT 46, CIT 22, and PBT + CIT 1) with CIEDs (64 pacemakers, 4 implantable cardioverter defibrillators, and 1 with a cardiac resynchronization therapy defibrillator) were retrospectively reviewed. All the patients with CIEDs in this study were treated with the passive scattering type of particle beam therapy. RESULTS Six (13%) of the 47 PBT patients, and none of the 23 CIT patients experienced CIED malfunctions (p = 0.105). Electrical resets (7) and over-sensing (3) occurred transiently in 6 patients. The distance between the edge of the irradiation field and the CIED was not associated with the incidence of malfunctions in 20 patients with lung cancer. A larger field size had a higher event rate but the test to evaluate trends as not statistically significant (p = 0.196). CONCLUSION Differences in the frequency of occurrence of device malfunctions for patients treated with PBT and patients treated with CIT did not reach statistical significance. The present study can be regarded as a benchmark study about the incidence of malfunctioning of CIED in passive scattering particle beam therapy and can be used as a reference for active scanning particle beam therapy.
Collapse
|
16
|
A treatment planning study of urethra-sparing intensity-modulated proton therapy for localized prostate cancer. Phys Imaging Radiat Oncol 2021; 20:23-29. [PMID: 34693040 PMCID: PMC8517200 DOI: 10.1016/j.phro.2021.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2021] [Revised: 09/24/2021] [Accepted: 09/29/2021] [Indexed: 11/17/2022] Open
Abstract
US-IMPT can potentially reduce the risk of genitourinary toxicities. The urethral NTCP value in US-IMPT is significantly lower than in the clinical plan. TCP for CTV did not differ significantly between the clinical and US-IMPT plans.
Background and Purpose Urethra-sparing radiation therapy for localized prostate cancer can reduce the risk of radiation-induced genitourinary toxicity by intentionally underdosing the periurethral transitional zone. We aimed to compare the clinical impact of a urethra-sparing intensity-modulated proton therapy (US-IMPT) plan with that of conventional clinical plans without urethral dose reduction. Materials and Methods This study included 13 patients who had undergone proton beam therapy. The prescribed dose was 63 GyE in 21 fractions for 99% of the clinical target volume. To compare the clinical impact of the US-IMPT plan with that of the conventional clinical plan, tumor control probability (TCP) and normal tissue complication probability (NTCP) were calculated with a generalized equivalent uniform dose-based Lyman–Kutcher model using dose volume histograms. The endpoints of these model parameters for the rectum, bladder, and urethra were fistula, contraction, and urethral stricture, respectively. Results The mean NTCP value for the urethra in US-IMPT was significantly lower than that in the conventional clinical plan (0.6% vs. 1.2%, p < 0.05). There were no statistically significant differences between the conventional and US-IMPT plans regarding the mean minimum dose for the urethra with a 3-mm margin, TCP value, and NTCP value for the rectum and bladder. Additionally, the target dose coverage of all plans in the robustness analysis was within the clinically acceptable range. Conclusions Compared with the conventional clinically applied plans, US-IMPT plans have potential clinical advantages and may reduce the risk of genitourinary toxicities, while maintaining the same TCP and NTCP in the rectum and bladder.
Collapse
|
17
|
Early and chronic phased local coagulative responses following bioresorbable-polymer drug-eluting stent implantation. Eur Heart J 2021. [DOI: 10.1093/eurheartj/ehab724.1245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Background
Neointimal maturation after bioresorbable-polymer (BP) drug-eluting stent (DES) implantation will not be complete in the absorption phase of the polymer. We have previously reported local persistent hypercoagulation after sirolimus-eluting stent (SES) implantation by measuring local plasma prothrombin fragment 1+2 (F1+2) levels. The aim of this study is to examine time-dependent local coagulative response after BP-DES implantation.
Methods
Sixty-four patients who were treated about ten months earlier with coronary angioplasty, with no evidence of restenosis, were studied [durable-polymer (DP)-DES {SES; Cypher®: 26pts and everolimus-eluting stent (EES); Xience®: 16pts} and BP-DES (BP-EES; Synergy®: 10pts and BP-SES; Ultimaster®: 12pts)]. We measured plasma levels of F1+2 sampled in coronary sinus (CS) and sinus of Valsalva (V) at the early (2±1 months) and chronic (10±2 months) phases. The transcardiac gradient (Δ) was defined as CS level minus V level.
Results
No significant differences were observed in the percent diameter stenosis between the DP- and BP- DES groups (11.5±15.5 vs 14.1±11.9%). The ΔF1+2 was significantly lower in the BP-DES group than in the DP-DES group at the chronic phase (7.5±16.1 vs 16.4±17.1pmol/l, p<0.05). In the BP-DES group, the ΔF1+2 did not differ significantly between the early and chronic phases (7.0±14.1 vs 7.5±16.1pmol/l, NS).
Conclusion
Lower local coagulative response was observed at the chronic phase after BP-DES implantation compared to DP-DES implantation, and local hypercoagulation after BP-DES implantation was not observed at the early phase compared to the chronic phase. These findings might lead to the possibility of shorter dual antiplatelet therapy after BP-DES implantation.
Funding Acknowledgement
Type of funding sources: None.
Collapse
|
18
|
Prediction of target position from multiple fiducial markers by partial least squares regression in real-time tumor-tracking radiation therapy. JOURNAL OF RADIATION RESEARCH 2021; 62:926-933. [PMID: 34196697 PMCID: PMC8438269 DOI: 10.1093/jrr/rrab054] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 03/24/2021] [Indexed: 06/13/2023]
Abstract
The purpose of this work is to show the usefulness of a prediction method of tumor location based on partial least squares regression (PLSR) using multiple fiducial markers. The trajectory data of respiratory motion of four internal fiducial markers inserted in lungs were used for the analysis. The position of one of the four markers was assumed to be the tumor position and was predicted by other three fiducial markers. Regression coefficients for prediction of the position of the tumor-assumed marker from the fiducial markers' positions is derived by PLSR. The tracking error and the gating error were evaluated assuming two possible variations. First, the variation of the position definition of the tumor and the markers on treatment planning computed tomograhy (CT) images. Second, the intra-fractional anatomical variation which leads the distance change between the tumor and markers during the course of treatment. For comparison, rigid predictions and ordinally multiple linear regression (MLR) predictions were also evaluated. The tracking and gating errors of PLSR prediction were smaller than those of other prediction methods. Ninety-fifth percentile of tracking/gating error in all trials were 3.7/4.1 mm, respectively in PLSR prediction for superior-inferior direction. The results suggested that PLSR prediction was robust to variations, and clinically applicable accuracy could be achievable for targeting tumors.
Collapse
|
19
|
First experimental results of gated proton imaging using x-ray fluoroscopy to detect a fiducial marker. Phys Med Biol 2021; 66. [PMID: 34433146 DOI: 10.1088/1361-6560/ac212b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Accepted: 08/25/2021] [Indexed: 11/12/2022]
Abstract
Increasing numbers of proton imaging research studies are being conducted for accurate proton range determination in proton therapy treatment planning. However, there is no proton imaging system that deals with motion artifacts. In this study, a gated proton imaging system was developed and the first experimental results of proton radiography (pRG) were obtained for a moving object without motion artifacts. A motion management system using dual x-ray fluoroscopy for detecting a spherical gold fiducial marker was introduced and the proton beam was gated in accordance with the motion of the object. To demonstrate the performance of the gated proton imaging system, gated pRG images of a moving phantom were acquired experimentally, and the motion artifacts clearly were diminished. Also, the factors causing image deteriorations were evaluated focusing on the new gating system developed here, and the main factor was identified as the latency (with a maximum value of 93 ms) between the ideal gating signal according to the actual marker position and the actual gating signal. The possible deterioration due to the latency of the proton imaging system and proton beam irradiation was small owing to appropriate setting of the time structure.
Collapse
|
20
|
Real-time CT image generation based on voxel-by-voxel modeling of internal deformation by utilizing the displacement of fiducial markers. Med Phys 2021; 48:5311-5326. [PMID: 34260755 DOI: 10.1002/mp.15095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 06/17/2021] [Accepted: 07/07/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To show the feasibility of real-time CT image generation technique utilizing internal fiducial markers that facilitate the evaluation of internal deformation. METHODS In the proposed method, a linear regression model that can derive internal deformation from the displacement of fiducial markers is built for each voxel in the training process before the treatment session. Marker displacement and internal deformation are derived from the four-dimensional computed tomography (4DCT) dataset. In the treatment session, the three-dimensional deformation vector field is derived according to the marker displacement, which is monitored by the real-time imaging system. The whole CT image can be synthesized by deforming the reference CT image with a deformation vector field in real-time. To show the feasibility of the technique, image synthesis accuracy and tumor localization accuracy were evaluated using the dataset generated by extended NURBS-Based Cardiac-Torso (XCAT) phantom and clinical 4DCT datasets from six patients, containing 10 CT datasets each. In the validation with XCAT phantom, motion range of the tumor in training data and validation data were about 10 and 15 mm, respectively, so as to simulate motion variation between 4DCT acquisition and treatment session. In the validation with patient 4DCT dataset, eight CT datasets from the 4DCT dataset were used in the training process. Two excluded inhale CT datasets can be regarded as the datasets with large deformations more than training dataset. CT images were generated for each respiratory phase using the corresponding marker displacement. Root mean squared error (RMSE), normalized RMSE (NRMSE), and structural similarity index measure (SSIM) between the original CT images and the synthesized CT images were evaluated as the quantitative indices of the accuracy of image synthesis. The accuracy of tumor localization was also evaluated. RESULTS In the validation with XCAT phantom, the mean NRMSE, SSIM, and three-dimensional tumor localization error were 7.5 ± 1.1%, 0.95 ± 0.02, and 0.4 ± 0.3 mm, respectively. In the validation with patient 4DCT dataset, the mean RMSE, NRMSE, SSIM, and three-dimensional tumor localization error in six patients were 73.7 ± 19.6 HU, 9.2 ± 2.6%, 0.88 ± 0.04, and 0.8 ± 0.6 mm, respectively. These results suggest that the accuracy of the proposed technique is adequate when the respiratory motion is within the range of the training dataset. In the evaluation with a marker displacement larger than that of the training dataset, the mean RMSE, NRMSE, and tumor localization error were about 100 HU, 13%, and <2.0 mm, respectively, except for one case having large motion variation. The performance of the proposed method was similar to those of previous studies. Processing time to generate the volumetric image was <100 ms. CONCLUSION We have shown the feasibility of the real-time CT image generation technique for volumetric imaging.
Collapse
|
21
|
Validation of dose distribution for liver tumors treated with real-time-image gated spot-scanning proton therapy by log data based dose reconstruction. JOURNAL OF RADIATION RESEARCH 2021; 62:626-633. [PMID: 33948661 PMCID: PMC8273791 DOI: 10.1093/jrr/rrab024] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 09/02/2020] [Indexed: 06/12/2023]
Abstract
In spot scanning proton therapy (SSPT), the spot position relative to the target may fluctuate through tumor motion even when gating the radiation by utilizing a fiducial marker. We have established a procedure that evaluates the delivered dose distribution by utilizing log data on tumor motion and spot information. The purpose of this study is to show the reliability of the dose distributions for liver tumors treated with real-time-image gated SSPT (RGPT). In the evaluation procedure, the delivered spot information and the marker position are synchronized on the basis of log data on the timing of the spot irradiation and fluoroscopic X-ray irradiation. Then a treatment planning system reconstructs the delivered dose distribution. Dose distributions accumulated for all fractions were reconstructed for eight liver cases. The log data were acquired in all 168 fractions for all eight cases. The evaluation was performed for the values of maximum dose, minimum dose, D99, and D5-D95 for the clinical target volumes (CTVs) and mean liver dose (MLD) scaled by the prescribed dose. These dosimetric parameters were statistically compared between the planned dose distribution and the reconstructed dose distribution. The mean difference of the maximum dose was 1.3% (95% confidence interval [CI]: 0.6%-2.1%). Regarding the minimum dose, the mean difference was 0.1% (95% CI: -0.5%-0.7%). The mean differences of D99, D5-D95 and MLD were below 1%. The reliability of dose distributions for liver tumors treated with RGPT-SSPT was shown by the evaluation of the accumulated dose distributions.
Collapse
|
22
|
Technical Note: Range verification of pulsed proton beams from fixed-field alternating gradient accelerator by means of time-of-flight measurement of ionoacoustic waves. Med Phys 2021; 48:5490-5500. [PMID: 34173991 DOI: 10.1002/mp.15060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2021] [Revised: 05/24/2021] [Accepted: 06/16/2021] [Indexed: 11/11/2022] Open
Abstract
PURPOSE Ionoacoustics is one of the promising approaches to verify the beam range in proton therapy. However, the weakness of the wave signal remains a main hindrance to its application in clinics. Here we studied the potential use of a fixed-field alternating gradient accelerator (FFA), one of the accelerator candidates for future proton therapy. For such end, magnitude of the pressure wave and range accuracy achieved by the short-pulsed beam of FFA were assessed, using both simulation and experimental procedure. METHODS A 100 MeV proton beam from the FFA was applied on a water phantom, through the acrylic wall. The beam range measured by the Bragg peak (BP)-ionization chamber (BPC) was 77.6 mm, while the maximum dose at BP was estimated to be 0.35 Gy/pulse. A hydrophone was placed 20 mm downstream of the BP, and signals were amplified and stored by a digital oscilloscope, averaged, and low-pass filtered. Time-of-flight (TOF) and two relative TOF values were analyzed in order to determine the beam range. Furthermore, an acoustic wave transport simulation was conducted to estimate the amplitude of the pressure waves. RESULTS The range calculated when using two relative TOF was 78.16 ± 0.01 and 78.14 ± 0.01 mm, respectively, both values being coherent with the range measured by the BPC (the difference was 0.5-0.6 mm). In contrast, utilizing the direct TOF resulted in a range error of 1.8 mm. Fivefold and 50-fold averaging were required to suppress the range variation to below 1 mm for TOF and relative TOF measures, respectively. The simulation suggested the magnitude of pressure wave at the detector exceeded 7 Pascal. CONCLUSION A submillimeter range accuracy was attained with a pulsed beam of about 21 ns from an FFA, at a clinical energy using relative TOF. To precisely quantify the range with a single TOF measurement, subsequent improvement in the measuring system is required.
Collapse
|
23
|
Feasibility of using polycarbonate as a substrate of thin film composite membrane in forward osmosis. J Appl Polym Sci 2021. [DOI: 10.1002/app.50511] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
24
|
Quadriceps strength to body weight ratio is a significant indicator for initiating jogging after anterior cruciate ligament reconstruction. Knee 2021; 28:240-246. [PMID: 33429149 DOI: 10.1016/j.knee.2020.12.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 11/25/2020] [Accepted: 12/18/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND Quadriceps strength recovery after anterior cruciate ligament (ACL) reconstruction is an important criterion for progress in rehabilitation and return to sports. The purpose of this study was to determine whether quadriceps strength to body weight ratio (QS/BW) is a significant indicator for initiating jogging after ACL reconstruction. METHODS Isokinetic quadriceps strength at 60°/s was measured and a jogging trial was completed 3 months after ACL reconstruction with hamstring tendon autograft in 83 patients (36 male, 47 female; mean age, 26.6 ± 12.4 years). Based on the jogging trial results, patients were assigned to either a successful jogging group (mean velocity ≥ 9 km/h) or an unsuccessful jogging group (mean velocity < 9 km/h). The association between QS/BW and successful jogging after surgery was investigated by multivariate logistic regression analysis and the cut-off value was determined by receiver operating characteristic analysis. RESULTS Forty-four patients (53.0%) were assigned to the successful jogging group and 39 (47.0%) to the unsuccessful jogging group. QS/BW was independently associated with initiating jogging 3 months after surgery. The cut-off value of QS/BW for successful jogging was 1.45 Nm/kg (area under the curve = 0.94; sensitivity = 88.6%, specificity = 87.2%). All of the patients who initiated jogging with QS/BW of > 1.45 Nm/kg at 3 months returned to sports without recurrence or contralateral injury by 10 months after surgery. CONCLUSIONS QS/BW is a significant indicator for safely initiating jogging 3 months after ACL reconstruction. The cut-off value of QS/BW for initiating jogging was 1.45 Nm/kg.
Collapse
|
25
|
Potential benefits of adaptive intensity-modulated proton therapy in nasopharyngeal carcinomas. J Appl Clin Med Phys 2020; 22:174-183. [PMID: 33338323 PMCID: PMC7856494 DOI: 10.1002/acm2.13128] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 11/24/2020] [Accepted: 11/25/2020] [Indexed: 11/29/2022] Open
Abstract
Purpose To investigate potential advantages of adaptive intensity‐modulated proton beam therapy (A‐IMPT) by comparing it to adaptive intensity‐modulated X‐ray therapy (A‐IMXT) for nasopharyngeal carcinomas (NPC). Methods Ten patients with NPC treated with A‐IMXT (step and shoot approach) and concomitant chemotherapy between 2014 and 2016 were selected. In the actual treatment, 46 Gy in 23 fractions (46Gy/23Fx.) was prescribed using the initial plan and 24Gy/12Fx was prescribed using an adapted plan thereafter. New treatment planning of A‐IMPT was made for the same patients using equivalent dose fractionation schedule and dose constraints. The dose volume statistics based on deformable images and dose accumulation was used in the comparison of A‐IMXT with A‐IMPT. Results The means of the Dmean of the right parotid gland (P < 0.001), right TM joint (P < 0.001), left TM joint (P < 0.001), oral cavity (P < 0.001), supraglottic larynx (P = 0.001), glottic larynx (P < 0.001), , middle PCM (P = 0.0371), interior PCM (P < 0.001), cricopharyngeal muscle (P = 0.03643), and thyroid gland (P = 0.00216), in A‐IMPT are lower than those of A‐IMXT, with statistical significance. The means of, D0.03cc, and Dmean of each sub portion of auditory apparatus and D30% for Eustachian tube and D0.5cc for mastoid volume in A‐IMPT are significantly lower than those of A‐IMXT. The mean doses to the oral cavity, supraglottic larynx, and glottic larynx were all reduced by more than 20 Gy (RBE = 1.1). Conclusions An adaptive approach is suggested to enhance the potential benefit of IMPT compared to IMXT to reduce adverse effects for patients with NPC.
Collapse
|
26
|
Proton dose calculation based on converting dual-energy CT data to stopping power ratio (DEEDZ-SPR): a beam-hardening assessment. ACTA ACUST UNITED AC 2020; 65:235046. [DOI: 10.1088/1361-6560/abae09] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
27
|
On-line range verification for proton beam therapy using spherical ionoacoustic waves with resonant frequency. Sci Rep 2020; 10:20385. [PMID: 33230208 PMCID: PMC7683547 DOI: 10.1038/s41598-020-77422-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2020] [Accepted: 11/10/2020] [Indexed: 01/01/2023] Open
Abstract
In contrast to conventional X-ray therapy, proton beam therapy (PBT) can confine radiation doses to tumours because of the presence of the Bragg peak. However, the precision of the treatment is currently limited by the uncertainty in the beam range. Recently, a unique range verification methodology has been proposed based on simulation studies that exploit spherical ionoacoustic waves with resonant frequency (SPIREs). SPIREs are emitted from spherical gold markers in tumours initially introduced for accurate patient positioning when the proton beam is injected. These waves have a remarkable property: their amplitude is linearly correlated with the residual beam range at the marker position. Here, we present proof-of-principle experiments using short-pulsed proton beams at the clinical dose to demonstrate the feasibility of using SPIREs for beam-range verification with submillimetre accuracy. These results should substantially contribute to reducing the range uncertainty in future PBT applications.
Collapse
|
28
|
Quantitative analysis of treatments using real-time image gated spot-scanning with synchrotron-based proton beam therapy system log data. J Appl Clin Med Phys 2020; 21:10-19. [PMID: 33151643 PMCID: PMC7769392 DOI: 10.1002/acm2.13029] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 08/11/2020] [Accepted: 09/01/2020] [Indexed: 01/01/2023] Open
Abstract
A synchrotron-based real-time image gated spot-scanning proton beam therapy (RGPT) system with inserted fiducial markers can irradiate a moving tumor with high accuracy. As gated treatments increase the beam delivery time, this study aimed to investigate the frequency of intra-field adjustments corresponding to the baseline shift or drift and the beam delivery efficiency of a synchrotron-based RGPT system. Data from 118 patients corresponding to 127 treatment plans and 2810 sessions between October 2016 and March 2019 were collected. We quantitatively analyzed the proton beam delivery time, the difference between the ideal beam delivery time based on a simulated synchrotron magnetic excitation pattern and the actual treatment beam delivery time, frequency corresponding to the baseline shift or drift, and the gating efficiency of the synchrotron-based RGPT system according to the proton beam delivery machine log data. The mean actual beam delivery time was 7.1 min, and the simulated beam delivery time in an ideal environment with the same treatment plan was 2.9 min. The average difference between the actual and simulated beam delivery time per session was 4.3 min. The average frequency of intra-field adjustments corresponding to baseline shift or drift and beam delivery efficiency were 21.7% and 61.8%, respectively. Based on our clinical experience with a synchrotron-based RGPT system, we determined the frequency corresponding to baseline shift or drift and the beam delivery efficiency using the beam delivery machine log data. To maintain treatment accuracy within ± 2.0 mm, intra-field adjustments corresponding to baseline shift or drift were required in approximately 20% of cases. Further improvements in beam delivery efficiency may be realized by shortening the beam delivery time.
Collapse
|
29
|
Toll-like receptor 9 is a novel therapeutic target to prevent atrial fibrillation. Eur Heart J 2020. [DOI: 10.1093/ehjci/ehaa946.0463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Atrial fibrillation (AF) is the most common type of arrhythmia seen in clinical practice. Recent studies suggest that inflammation contributes to the pathogenesis of AF. On the other hand, several evidence suggests that toll-like receptor (TLR) 9 recognizes bacterial DNA, activating innate immunity, whereas it also provokes inflammation in response to fragmented DNA released from mammalian cells. Recently, we have reported that TLR 9 plays a pivotal role in the development of vascular inflammation and atherogenesis through proinflammatory activation of macrophages.
Purpose
This study aimed to assess whether TLR9 contributes to the AF arrhythmogenesis.
Methods
TLR9 deficient (TLR9−/−) and wild-type mice were infused with angiotensin II (Ang II) or vehicle via an osmotic minipump for 4 weeks. Blood pressure and body weight were measured serially. Then, we examined AF inducibility by intracardiac electrophysiological study and the inflammation-induced atrial remodeling by biochemical analysis after 4 weeks of Ang II infusion.
Results
There was no significant difference in blood pressure and pulse rate between TLR9−/− and wild-type mice both before and after Ang II infusion. Ang II-treated TLR9−/− mice showed lower incidence of AF compared with wild-type mice treated with Ang II. Genetic deletion of TLR9 significantly reduced the interstitial fibrosis in atrium of Ang II-treated mice. TLR9−/− mice also showed less mRNA expressions of inflammatory and fibrosis-related biomarkers (TNF-α, interleukin-6, TGF-β, collagen-1, collagen-3) in atrium compared with wild-type mice.
Conclusions
TLR9 might contribute to the AF arrhythmogenesis associated with atrial inflammation. TLR9 might serve as a potential therapeutic target for AF.
Funding Acknowledgement
Type of funding source: None
Collapse
|
30
|
Normal Tissue Complication Probability for Hematologic and Gastrointestinal Toxicity in Postoperative Whole Pelvic Radiotherapy for Gynecologic Malignancies using Intensity Modulated Proton Therapy with Robust Optimization. Int J Radiat Oncol Biol Phys 2020. [DOI: 10.1016/j.ijrobp.2020.07.1563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
31
|
The impact of dose delivery time on biological effectiveness in proton irradiation with various biological parameters. Med Phys 2020; 47:4644-4655. [PMID: 32652574 DOI: 10.1002/mp.14381] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 05/31/2020] [Accepted: 06/19/2020] [Indexed: 12/14/2022] Open
Abstract
PURPOSE The purpose of this study is to evaluate the sublethal damage (SLD) repair effect in prolonged proton irradiation using the biophysical model with various cell-specific parameters of (α/β)x and T1/2 (repair half time). At present, most of the model-based studies on protons have focused on acute radiation, neglecting the reduction in biological effectiveness due to SLD repair during the delivery of radiation. Nevertheless, the dose-rate dependency of biological effectiveness may become more important as advanced treatment techniques, such as hypofractionation and respiratory gating, come into clinical practice, as these techniques sometimes require long treatment times. Also, while previous research using the biophysical model revealed a large repair effect with a high physical dose, the dependence of the repair effect on cell-specific parameters has not been evaluated systematically. METHODS Biological dose [relative biological effectiveness (RBE) × physical dose] calculation with repair included was carried out using the linear energy transfer (LET)-dependent linear-quadratic (LQ) model combined with the theory of dual radiation action (TDRA). First, we extended the dose protraction factor in the LQ model for the arbitrary number of different LET proton irradiations delivered sequentially with arbitrary time lags, referring to the TDRA. Using the LQ model, the decrease in biological dose due to SLD repair was systematically evaluated for spread-out Bragg peak (SOBP) irradiation in a water phantom with the possible ranges of both (α/β)x and repair parameters ((α/β)x = 1-15 Gy, T1/2 = 0-90 min). Then, to consider more realistic irradiation conditions, clinical cases of prostate, liver, and lung tumors were examined with the cell-specific parameters for each tumor obtained from the literature. Biological D99% and biological dose homogeneity coefficient (HC) were calculated for the clinical target volumes (CTVs), assuming dose-rate structures with a total irradiation time of 0-60 min. RESULTS The differences in the cell-specific parameters resulted in considerable variation in the repair effect. The biological dose reduction found at the center of the SOBP with 30 min of continuous irradiation varied from 1.13% to 14.4% with a T1/2 range of 1-90 min when (α/β)x is fixed as 10 Gy. It varied from 2.3% to 6.8% with an (α/β)x range of 1-15 Gy for a fixed value of T1/2 = 30 min. The decrease in biological D99% per 10 min was 2.6, 1.2, and 3.0% for the prostate, liver, and lung tumor cases, respectively. The value of the biological D99% reduction was neither in the order of (α/β)x nor prescribed dose, but both comparably contributed to the repair effect. The variation of HC was within the range of 0.5% for all cases; therefore, the dose distribution was not distorted. CONCLUSION The reduction in biological dose caused by the SLD repair largely depends on the cell-specific parameters in addition to the physical dose. The parameters should be considered carefully in the evaluation of the repair effect in prolonged proton irradiation.
Collapse
|
32
|
Difference in LET-based biological doses between IMPT optimization techniques: Robust and PTV-based optimizations. J Appl Clin Med Phys 2020; 21:42-50. [PMID: 32150329 PMCID: PMC7170293 DOI: 10.1002/acm2.12844] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 02/01/2020] [Accepted: 02/10/2020] [Indexed: 12/03/2022] Open
Abstract
Purpose While a large amount of experimental data suggest that the proton relative biological effectiveness (RBE) varies with both physical and biological parameters, current commercial treatment planning systems (TPS) use the constant RBE instead of variable RBE models, neglecting the dependence of RBE on the linear energy transfer (LET). To conduct as accurate a clinical evaluation as possible in this circumstance, it is desirable that the dosimetric parameters derived by TPS (DRBE=1.1) are close to the “true” values derived with the variable RBE models (DvRBE). As such, in this study, the closeness of DRBE=1.1 to DvRBE was compared between planning target volume (PTV)‐based and robust plans. Methods Intensity‐modulated proton therapy (IMPT) treatment plans for two Radiation Therapy Oncology Group (RTOG) phantom cases and four nasopharyngeal cases were created using the PTV‐based and robust optimizations, under the assumption of a constant RBE of 1.1. First, the physical dose and dose‐averaged LET (LETd) distributions were obtained using the analytical calculation method, based on the pencil beam algorithm. Next, DvRBE was calculated using three different RBE models. The deviation of DvRBE from DRBE=1.1 was evaluated with D99 and Dmax, which have been used as the evaluation indices for clinical target volume (CTV) and organs at risk (OARs), respectively. The influence of the distance between the OAR and CTV on the results was also investigated. As a measure of distance, the closest distance and the overlapped volume histogram were used for the RTOG phantom and nasopharyngeal cases, respectively. Results As for the OAR, the deviations of DmaxvRBE from DmaxRBE=1.1 were always smaller in robust plans than in PTV‐based plans in all RBE models. The deviation would tend to increase as the OAR was located closer to the CTV in both optimization techniques. As for the CTV, the deviations of D99vRBE from D99RBE=1.1 were comparable between the two optimization techniques, regardless of the distance between the CTV and the OAR. Conclusion Robust optimization was found to be more favorable than PTV‐based optimization in that the results presented by TPS were closer to the “true” values and that the clinical evaluation based on TPS was more reliable.
Collapse
|
33
|
Dynamic gating window technique for the reduction of dosimetric error in respiratory-gated spot-scanning particle therapy: An initial phantom study using patient tumor trajectory data. J Appl Clin Med Phys 2020; 21:13-21. [PMID: 32068347 PMCID: PMC7170289 DOI: 10.1002/acm2.12832] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2019] [Revised: 01/06/2020] [Accepted: 01/14/2020] [Indexed: 11/22/2022] Open
Abstract
Spot‐scanning particle therapy possesses advantages, such as high conformity to the target and efficient energy utilization compared with those of the passive scattering irradiation technique. However, this irradiation technique is sensitive to target motion. In the current clinical situation, some motion management techniques, such as respiratory‐gated irradiation, which uses an external or internal surrogate, have been clinically applied. In surrogate‐based gating, the size of the gating window is fixed during the treatment in the current treatment system. In this study, we propose a dynamic gating window technique, which optimizes the size of gating window for each spot by considering a possible dosimetric error. The effectiveness of the dynamic gating window technique was evaluated by simulating irradiation using a moving target in a water phantom. In dosimetric characteristics comparison, the dynamic gating window technique exhibited better performance in all evaluation volumes with different effective depths compared with that of the fixed gate approach. The variation of dosimetric characteristics according to the target depth was small in dynamic gate compared to fixed gate. These results suggest that the dynamic gating window technique can maintain an acceptable dose distribution regardless of the target depth. The overall gating efficiency of the dynamic gate was approximately equal or greater than that of the fixed gating window. In dynamic gate, as the target depth becomes shallower, the gating efficiency will be reduced, although dosimetric characteristics will be maintained regardless of the target depth. The results of this study suggest that the proposed gating technique may potentially improve the dose distribution. However, additional evaluations should be undertaken in the future to determine clinical applicability by assuming the specifications of the treatment system and clinical situation.
Collapse
|
34
|
Analysis of treatment process time for real-time-image gated-spot-scanning proton-beam therapy (RGPT) system. J Appl Clin Med Phys 2019; 21:38-49. [PMID: 31886616 PMCID: PMC7020995 DOI: 10.1002/acm2.12804] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 10/27/2019] [Accepted: 12/03/2019] [Indexed: 12/16/2022] Open
Abstract
We developed a synchrotron‐based real‐time‐image gated‐spot‐scanning proton‐beam therapy (RGPT) system and utilized it to clinically operate on moving tumors in the liver, pancreas, lung, and prostate. When the spot‐scanning technique is linked to gating, the beam delivery time with gating can increase, compared to that without gating. We aim to clarify whether the total treatment process can be performed within approximately 30 min (the general time per session in several proton therapy facilities), even for gated‐spot‐scanning proton‐beam delivery with implanted fiducial markers. Data from 152 patients, corresponding to 201 treatment plans and 3577 sessions executed from October 2016 to June 2018, were included in this study. To estimate the treatment process time, we utilized data from proton beam delivery logs during the treatment for each patient. We retrieved data, such as the disease site, total target volume, field size at the isocenter, and the number of layers and spots for each field, from the treatment plans. We quantitatively analyzed the treatment process, which includes the patient load (or setup), bone matching, marker matching, beam delivery, patient unload, and equipment setup, using the data obtained from the log data. Among all the cases, 90 patients used the RGPT system (liver: n = 34; pancreas: n = 5; lung: n = 4; and prostate: n = 47). The mean and standard deviation (SD) of the total treatment process time for the RGPT system was 30.3 ± 7.4 min, while it was 25.9 ± 7.5 min for those without gating treatment, excluding craniospinal irradiation (CSI; head and neck: n = 16, pediatric: n = 31, others: n = 15); for CSI (n = 11) with two or three isocenters, the process time was 59.9 ± 13.9 min. Our results demonstrate that spot‐scanning proton therapy with a gating function can be achieved in approximately 30‐min time slots.
Collapse
|
35
|
A new SOBP-formation method by superposing specially shaped Bragg curves formed by a mini-ridge filter for spot scanning in proton beam therapy. Phys Med 2019; 67:70-76. [DOI: 10.1016/j.ejmp.2019.10.036] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2018] [Revised: 08/30/2019] [Accepted: 10/21/2019] [Indexed: 12/11/2022] Open
|
36
|
P2813The improvement of chronic local coagulative response according to the progress of drug eluting stent. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz748.1125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Abstract
Background
We have previously reported local persistent hypercoagulation after sirolimus-eluting stent (SES) implantation by measuring local plasma prothrombin fragment 1+2 (F1+2) levels. The aim of this study is to examine chronic local coagulative response after each generation- drug eluting stent (DES) implantation.
Methods
Ninety-five patients who were treated about eight months earlier with coronary angioplasty, with no evidence of restenosis, were studied [1stgeneration durable polymer (DP)-DES {SES; Cypher®: 26pts, paclitaxel-eluting stent (PES); Taxus®:16pts}, 2ndgeneration DP-DES {everolimus-eluting stent (EES); Xience®:15pts, zotarolimus-eluting stent (ZES); Endeavor®:15pts}, and 3rdgeneration biodegradable polymer (BP)-DES {BP-biolimus-eluting stent (BES); Nobori®: 11pts and BP-SES; Ultimaster®: 12pts}]. We measured plasma levels of F1+2 sampled in coronary sinus (CS) and sinus of Valsalva (V). The transcardiac gradient (Δ) was defined as CS level minus V level.
Results
No significant differences were observed in the percent diameter stenosis among 1st, 2nd, and 3rd DES groups (12.5±15.5 vs 16.1±12.9 vs 13.1±11.9%). The ΔF1+2 was significantly lower in the 2nd and 3rd DES groups than in the 1st DES group (9.0±15.4 and 10.0±17.4 vs 27.3±23.8pmol/l, p<0.05, respectively). The ΔF1+2 was significantly lower in the BP-DES groups (BP-BES and BP-SES) than in the DP-DES groups (DP-SES, DP-PES, DP-ZES, and DP-EES) (10.0±17.4 vs 18.1±19.5pmol/l, p<0.05). The ΔF1+2 was significantly lower in the thin strut-DES groups (BP-SES, DP-ZES, and DP-EES) than in the thick strut-DES groups (DP-SES, DP-PES, and BP-BES) (8.4±15.4 vs 21.7±18.5pmol/l, p<0.05). In the BP-DES groups, the ΔF1+2 was lower in the BP-SES group than in the BP-BES group (8.0±16.1 vs 12.7±18.1pmol/l, p=0.08).
Conclusions
The improvement of chronic local coagulative response was observed according to the progress of DES. These findings might be associated with lower strut thickness and faster polymer resorption in the newer-generation DES.
Collapse
|
37
|
P3389Angioscopic differences in quality and quantity of neointima in patients experiencing an acute coronary syndrome treated with bare metal, first-, second-, and third generation drug-eluting stents. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz745.0265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Although drug-eluting stents (DES) have substantially reduced the need for early target lesion revascularization (TLR) compared with bare-metal stents (BMS) by inhibiting neointima hyperplasia, early generation DES have been associated with an increased risk of very late stent failure (VLSF) due to stent thrombosis and TLR after 1 year. Although the incidence of VLSF is reduced with newer generation DES, VLSF remains an unresolved problem and its mechanisms are not fully explored.
Purpose
The purpose of this study was to evaluate quality and quantity of neointima and presence of thrombus by using coronary angioscopy at long-term follow-up in patients who experienced an acute coronary syndrome (ACS) treated with BMS and DES on dual antiplatelet therapy.
Methods
Coronary angioscopy was performed at 6 and 10 months after BMS and DES implantation, respectively, in ACS patients. We assessed neointimal coverage (NC) of the stent struts, yellow color grade (YG) of stented segment and the existence of thrombus. Angioscopic NC was defined as follows: grade 0= fully visible struts; grade 1= visible struts through thin neointima; grade 2= no visible struts. We determined maximum (Max-NC) and minimum coverage (Min-NC) grades and the dominant NC grades. YG was classified into 4 grades (0= white; 1= slight yellow; 2= yellow; 3= intensive yellow). The obtained findings were compared with BMS, first-generation (1st-) DES, second-generation (2nd-) DES and third-generation (3rd-) DES.
Results
A total of 212 patients were enrolled: BMS (n=127), 1st DES (n=26, sirolimus-eluting stent), 2nd-DES (n=38, permanent polymer everolimus-eluting stent), and 3rd-DES (n=21, bioresorbable polymer everolimus-eluting stent). Max-NC and Min-NC grade were significantly lower with 1st- and 2nd-DES than with BMS and 3rd-DES (Figure). The same trend was also observed in the dominant NC grades. There was a lower trend of YG in BMS and 3rd-DES than in 1st or 2nd-DES (Figure). The presence of thrombus was significantly lower in 3rd-DES in comparison with BMS, 1st-, and 2nd-DES (3rd-DES 0%, BMS 20.5%, 1st-DES 24%, 2nd-DES 13.5%, P=0.01).
Figure 1
Conclusion
Patients treated with 3rd-DES have higher NC grade, lower incidence of intrastent thrombus, and lower YG than in 1st and 2nd-DES. These findings may explain the lower incidence of VLSF associated with these newer generation stent platforms.
Collapse
|
38
|
P2867Vildagliptin reduces inducibility of atrial fibrillation in hypertensive rats complicated with diabetes mellitus. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz748.1176] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Abstract
Background
Atrial fibrillation (AF) is the most common arrhythmia in clinical practice, increasing the incidence of ischemic stroke. Diabetes mellitus (DM) is a predictor of stroke and thromboembolism, and it was reported to be an independent risk factor for AF. A recent study has shown that, in obese mice with diabetes, dipeptidyl peptidase-4 (DPP-4) inhibitor prevents myocardial fibrosis, active oxygen stress, weight loss and improves myocardial hypertrophy. However, the effects of DPP-4 inhibitors on atrial remodeling associated with diabetes and atrial fibrillation have not yet been clarified.
Purpose
This study was performed to assess whether a DPP-4 inhibitor (vildagliptin) ameliorates atrial remodeling in spontaneously hypertensive rats (SHR) with streptozotocin-induced diabetes.
Methods
Rats were divided into 3 groups: SHR without DM, SHR with DM treated with vehicle and SHR-DM treated with vildagliptin (3mg/kg/day; intragastric gavage). For each group, blood pressure, blood glucose level and body weight were measured serially. Cardiac function was also evaluated by echocardiography. Then, we examined AF inducibility by intracardiac electrophysiological study and the inflammation-induced atrial remodeling by biochemical analysis after 4 weeks of treatment.
Results
There was no significant difference in blood pressure and blood gucose level between vehicle and vildagliptin groups. Administration of vildagliptin significantly reduced AF inducibility compared with rats with vehicle. In DM rats treated with vehicle, rapid atrial pacing promoted the gene expression of inflammatory and fibrosis-related biomarkers (TNF-α, MCP-1, collagen-1) in atrium. Vildagliptin reduced these gene expression levels. In addition, administration of vildagliptin significantly reduced the interstitial fibrosis in atrium.
Conclusions
DPP-4 inhibitor, vildagliptin. could prevent atrial inflammation and reduce the AF inducibility in SHR complicated with DM.
Collapse
|
39
|
Superhydrophobic nanofibers electrospun by surface segregating fluorinated amphiphilic additive for membrane distillation. J Memb Sci 2019. [DOI: 10.1016/j.memsci.2019.117215] [Citation(s) in RCA: 49] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
|
40
|
P6441New continuous glucose monitoring reveals hypoglycemia risk in both diabetic and nondiabetic patients with acute myocardial infarction. Eur Heart J 2019. [DOI: 10.1093/eurheartj/ehz746.1035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Abstract
Background
There has been growing evidence that the glucose fluctuation is an important contributing factor to the development of coronary artery disease. However, whether large glucose fluctuation, especially hypoglycemia, may be associated with acute myocardial infarction (AMI) remains largely unknown.
Aim
As new continuous glucose monitoring (CGM) has recently become available to evaluate glucose fluctuation from immediately after an emergency visit, this study sought to investigate glucose fluctuation and the occurrence of hypoglycemia in patients with AMI.
Methods
In this prospective study, 93 consecutive patients with AMI from April 2017 to November 2018 were enrolled. Subcutaneous interstitial glucose levels were monitored from emergency room to discharge using the CGM System. Based on the CGM data, 24-h mean glucose levels, the time in hyperglycemia and hypoglycemia and the occurrence of hypoglycemia, defined as less than 70 mg/dL, were measured, and the mean amplitude of glycemic excursions (MAGE) were calculated.
Results
The majority of patients [n=57, 61% (non-DM)] did not have diabetes and 36 patients had diabetes (DM). The occurrence of hypoglycemia within 24 hours after admission was observed in 49 patients [DM: n=11 (30.6%), non-DM: n=38 (66.7%)]. MAGE within 24 hours after admission were 100±47 in DM patients and 67±20 in non-DM patients. The mean time in hypoglycemia within 24 hours after admission was 148 minutes [DM: 100±260 minutes, non-DM: 178±287 minutes]. The occurrence of hypoglycemia during a hospital stay (mean 11.5 days) was detected in 76 patients [DM: n=28 (77.8%), non-DM: n=48 (84.2%)].
Representative case of hypoglycemia
Conclusion
Not only in DM patients but also in non-DM patients with AMI, large glucose fluctuation and high incidence of hypoglycemia were observed using new CGM system. Further investigations should address the rationale for the early detection and control of glucose fluctuation for AMI patients.
Collapse
|
41
|
Initial Clinical Outcomes of Real-Time-Image Gated Spot-Scanning Proton Beam Therapy for Hepatocellular Carcinomas. Int J Radiat Oncol Biol Phys 2019. [DOI: 10.1016/j.ijrobp.2019.06.1977] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
42
|
Clinical experience of craniospinal intensity-modulated spot-scanning proton therapy using large fields for central nervous system medulloblastomas and germ cell tumors in children, adolescents, and young adults. JOURNAL OF RADIATION RESEARCH 2019; 60:527-537. [PMID: 31111946 PMCID: PMC6640905 DOI: 10.1093/jrr/rrz022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/25/2018] [Revised: 02/28/2019] [Indexed: 06/09/2023]
Abstract
The outcomes of intensity-modulated proton craniospinal irradiation (ipCSI) are unclear. We evaluated the clinical benefit of our newly developed ipCSI system that incorporates two gantry-mounted orthogonal online X-ray imagers with a robotic six-degrees-of-freedom patient table. Nine patients (7-19 years old) were treated with ipCSI. The prescribed dose for CSI ranged from 23.4 to 36.0 Gy (relative biological effectiveness) in 13-20 fractions. Four adolescent and young adult (AYA) patients (15 years or older) were treated with vertebral-body-sparing ipCSI (VBSipCSI). Myelosuppression following VBSipCSI was compared with that of eight AYA patients treated with photon CSI at the same institution previously. The mean homogeneity index (HI) in the nine patients was 0.056 (95% confidence interval: 0.044-0.068). The mean time from the start to the end of all beam delivery was 37 min 39 s ± 2 min 24 s (minimum to maximum: 22 min 49 s - 42 min 51 s). The nadir white blood cell, hemoglobin, and platelet levels during the 4 weeks following the end of the CSI were significantly higher in the VBSipCSI group than in the photon CSI group (P = 0.0071, 0.0453, 0.0024, respectively). The levels at 4 weeks after the end of CSI were significantly higher in the VBSipCSI group than in the photon CSI group (P = 0.0023, 0.0414, 0.0061). Image-guided ipCSI was deliverable in a reasonable time with sufficient HI. Using VBSipCSI, AYA patients experienced a lower incidence of serious acute hematological toxicity than AYA patients treated with photon CSI.
Collapse
|
43
|
Physical and biological impacts of collimator-scattered protons in spot-scanning proton therapy. J Appl Clin Med Phys 2019; 20:48-57. [PMID: 31237090 PMCID: PMC6612695 DOI: 10.1002/acm2.12653] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2019] [Revised: 05/01/2019] [Accepted: 05/04/2019] [Indexed: 11/29/2022] Open
Abstract
To improve the penumbra of low‐energy beams used in spot‐scanning proton therapy, various collimation systems have been proposed and used in clinics. In this paper, focused on patient‐specific brass collimators, the collimator‐scattered protons' physical and biological effects were investigated. The Geant4 Monte Carlo code was used to model the collimators mounted on the scanning nozzle of the Hokkaido University Hospital. A systematic survey was performed in water phantom with various‐sized rectangular targets; range (5–20 cm), spread‐out Bragg peak (SOBP) (5–10 cm), and field size (2 × 2–16 × 16 cm2). It revealed that both the range and SOBP dependences of the physical dose increase had similar trends to passive scattering methods, that is, it increased largely with the range and slightly with the SOBP. The physical impact was maximized at the surface (3%–22% for the tested geometries) and decreased with depth. In contrast, the field size (FS) dependence differed from that observed in passive scattering: the increase was high for both small and large FSs. This may be attributed to the different phase‐space shapes at the target boundary between the two dose delivery methods. Next, the biological impact was estimated based on the increase in dose‐averaged linear energy transfer (LETd) and relative biological effectiveness (RBE). The LETd of the collimator‐scattered protons were several keV/μm higher than that of unscattered ones; however, since this large increase was observed only at the positions receiving a small scattered dose, the overall LETd increase was negligible. As a consequence, the RBE increase did not exceed 0.05. Finally, the effects on patient geometries were estimated by testing two patient plans, and a negligible RBE increase (0.9% at most in the critical organs at surface) was observed in both cases. Therefore, the impact of collimator‐scattered protons is almost entirely attributed to the physical dose increase, while the RBE increase is negligible.
Collapse
|
44
|
A Literature Review of Proton Beam Therapy for Prostate Cancer in Japan. J Clin Med 2019; 8:jcm8010048. [PMID: 30621278 PMCID: PMC6352078 DOI: 10.3390/jcm8010048] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2018] [Revised: 12/23/2018] [Accepted: 12/28/2018] [Indexed: 12/14/2022] Open
Abstract
Aim: Patients of proton beam therapy (PBT) for prostate cancer had been continuously growing in number due to its promising characteristics of high dose distribution in the tumor target and a sharp distal fall-off. Considering the large number of proton beam facilities in Japan, the further increase of patients undergoing this treatment is due to the emendations by Japanese National Health Insurance (NHI) and the development of medical equipment and technology, it is necessary to know what kind of research and advancements has been done on proton therapy for prostate cancer in the country. For these reasons, this literature review was conducted. The aim of this review is to identify and discuss research studies of proton beam therapy for prostate cancer in Japan. These include observational, interventional, and secondary data analysis of published articles. Method: A literature review on published works related to proton beam therapy for prostate cancer in Japan was conducted using articles that were gathered in the PubMed database of June 2018. We went through abstracts and manuscripts written in English with the keywords ‘proton beam therapy’, ‘prostate cancer’, and ‘Japan’. Results: A total of 23 articles were included. Fourteen articles were observational studies, most of which focused on the adverse effects of Proton Beam Therapy (PBT). Seven articles were interventional studies related on treatment planning, equipment parts, as well as target positioning. Two were secondary data analysis. The included studies were published in 13 different journals by different institutions using various equipment. Conclusion: Despite the favorable results of proton beam therapy, future research should include more patients and longer follow-up schedules to clarify the definitive role of PBT, yet, up to recent retrospective studies, included in this paper, concluded that PBT can be a suitable treatment option for localized prostate cancer. In addition, interventional studies were conducted by several institutions to further embellish proton therapy.
Collapse
|
45
|
Impact of Donor Age on Outcome of Intestinal Transplantation in Japan. Transplant Proc 2018; 50:2775-2778. [PMID: 30401396 DOI: 10.1016/j.transproceed.2018.04.021] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2018] [Revised: 03/25/2018] [Accepted: 04/09/2018] [Indexed: 01/10/2023]
Abstract
BACKGROUND Donor age for intestinal transplantation (ITx) is somewhat younger than that for other solid organs. Clear criteria for adequate donors have not been established. There is a donor scarcity for ITx in Japan due to the shortage of young donors. METHODS We reviewed outcomes associated with ITx in Japan based on donor age for cadaveric and living donation. RESULTS Standardized report forms were sent to all known ITx programs, asking for information on ITxs performed between 1996 and 2016. All programs responded. Patient and graft survival estimates were obtained using the Kaplan-Meier method. Five institutions provided data on 27 grafts in 24 patients. There were 14 cadaveric and 13 living donor transplants. Median donor age for ITxs was 40 (range, 17-60) years. Graft survival at 5 years was 66% for patients >40 years old (n = 18) and 47% for those <40 years old (n = 9), not a statistically significant difference (P = .49). Graft survival at 5 years was 60% in those >50 years old (n = 5) and 57% for those <50 years old (n = 22), again not a significant difference (P = .27). CONCLUSION There is no difference in survival between for those with donor age <40 vs >40 years. Donor age for ITx can be extended from >40 to up to 50 years, which may help to mitigate the donor shortage. It will be necessary to clarify the donor criteria for ITx through accumulation of further data on ITx.
Collapse
|
46
|
Intensity-Modulated Proton Therapy with Dose Painting based on Hypoxia Imaging for Nasopharyngeal Cancer. Int J Radiat Oncol Biol Phys 2018. [DOI: 10.1016/j.ijrobp.2018.07.1125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
47
|
Analysis of Beam Delivery Times and Dose Rates for the Treatment of Mobile Tumors Using Real Time Image Gated Spot-Scanning Proton Beam Therapy. Int J Radiat Oncol Biol Phys 2018. [DOI: 10.1016/j.ijrobp.2018.07.062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
48
|
Three-Year Prospective Follow-up of Potential Pediatric Candidate for Intestinal Transplantation. Transplant Proc 2018; 50:2779-2782. [DOI: 10.1016/j.transproceed.2018.03.067] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Accepted: 03/06/2018] [Indexed: 11/16/2022]
|
49
|
P1862Preeclampsia induces the acquired salt-sensitivity characteristics via the increased vasopressin secretion in postpartum. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy565.p1862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
50
|
P3732C-type natriuretic peptide improves left ventricular diastolic dysfunction and ischemia/reperfusion injury-associated ventricular arrhythmias. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy563.p3732] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|