1
|
[Determination of three furfural compounds in coffee and coffee products by gas chromatography-tandem mass spectrometry with internal standard isotope]. WEI SHENG YAN JIU = JOURNAL OF HYGIENE RESEARCH 2023; 52:280-291. [PMID: 37062692 DOI: 10.19813/j.cnki.weishengyanjiu.2023.02.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 04/18/2023]
Abstract
OBJECTIVE To establish a method for the determination of three furfural compounds in coffee and its products by gas chromatography-tandem mass spectrometry. METHODS The samples were extracted with ethanol water(1∶2, V∶V) solution, ultrasonic with 10% Na_2CO_3 solution for 5 min, purified with 100 mg C_(18), 50 mg Srong Cation exchang(SCX), 150 mg anhydrous MgSO_4, separated by HP-INNOWAX capillary column(30 m×0.25 mm, 0.25 μm), detected by gas chromatography-tandem mass spectrometry, and quantified by isotope internal standard method. RESULTS The correlation coefficients(r) of the three furfural compounds were all greater than 0.999, the limits of detection were 0.004-0.011 mg/kg, and the limits of quantitation were 0.013-0.031 mg/kg. The average recoveries were 86.0%-112% and the relative standard deviations were 4.1%-10.6%(n=6), at 3 supplemental levels in 3 different coffee substrates. Nine samples of coffee beans, instant coffee and coffee drinks were tested, and all three components to be tested were detected. CONCLUSION The method is simple, rapid, sensitive, with good accuracy and precision. It is suitable for the determination of three furfural compounds in coffee and its products.
Collapse
|
2
|
Multiresidue analysis of pesticides in three Indian soils: method development and validation using gas chromatography tandem mass spectrometry. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART. B, PESTICIDES, FOOD CONTAMINANTS, AND AGRICULTURAL WASTES 2023; 58:158-194. [PMID: 36840342 DOI: 10.1080/03601234.2023.2175578] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The paper reports a multiresidue method that was validated on 220 multi-class pesticides in three major Indian soils, namely, (i) new alluvial soil (NAS); (ii) red lateritic soil (RS) and (iii) black soil (BS) from three different regions. An ethyl acetate-based extraction method with a freezing-out cleanup step was employed for sample preparation, followed by gas chromatography-tandem mass spectrometric analysis. The method that was initially optimized on BS worked satisfactorily for the other two soil matrices. At the spiking level of 10 µg/kg (LOQ), the recoveries were satisfactory (within 70-120%) with precision-RSDs, ≤20% (n = 6) for 85, 88.6, and 89% of compounds in BS, RS, and NAS respectively. At 20 µg/kg, the method performance was satisfactory in each soil for all pesticides. When this validated method was applied to analyse 25 field samples, 6 pesticides were detected in them. In each case, precision (RSD) was <20%. The method sensitivity, accuracy and precision complied with the SANTE/2020/12830 guidelines. The method can be applied for environmental monitoring and risk assessment purposes, thus aiding in regulating pesticide usage in agricultural fields. The limitations and future scope of the study are also discussed.HighlightsA multiresidue method is reported for simultaneous analysis of multi-class pesticides in diverse soilsThe method was validated on 220 pesticides in new alluvial, red lateritic and black soilsSample preparation involved extraction with ethyl acetate and cleanup by a freezing stepThe residues were estimated by gas chromatography tandem mass spectrometry (GC-MS/MS)The method accuracy and precision complied with the EU's SANTE guidelines.
Collapse
|
3
|
Fabrication of magnetic covalent organic framework for efficient extraction and determination of phthalate esters in milk samples. J Sep Sci 2022; 45:3014-3021. [PMID: 35728929 DOI: 10.1002/jssc.202200240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2022] [Revised: 06/16/2022] [Accepted: 06/17/2022] [Indexed: 11/11/2022]
Abstract
Using two monomers of 4,4″-diamino-p-terphenyl and 1,3,5-triformylphloroglucinol, a co-precipitation structured magnetic covalent organic framework adsorbent was fabricated. After that, a high efficient vortex-assisted magnetic solid-phase extraction method was developed prior to gas chromatography-tandem mass spectrometry analysis for the determination of phthalate esters in milk samples. The fabricated magnetic adsorbent was facilely fabricated, fully characterized, and exhibited high extraction efficiency, which can be attributed to its larger pore size as well as strong hydrophobic and π-π stacking interactions between adsorbent and phthalate esters. Key parameters affecting extraction efficiency were investigated. Under the optimized conditions, the proposed method possessed good linearity (3.0-1000 μg/L), high sensitivity (0.8-2.1 μg/L for limits of detection), and satisfactory recoveries (76.8%-99.2%). The relative standard deviations for intra-day was 3.1%-4.5% and inter-day was 3.3%-6.1%. This work is suitable for high efficient separation/preconcentration of phthalate esters in milk samples.
Collapse
|
4
|
Trace-level analysis of polychlorinated biphenyls, organochlorine pesticides and polycyclic aromatic hydrocarbons in human plasma or serum by dispersive liquid-liquid microextraction and gas chromatography-tandem mass spectrometry. Biomed Chromatogr 2022; 36:e5360. [PMID: 35261063 DOI: 10.1002/bmc.5360] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 02/21/2022] [Accepted: 02/24/2022] [Indexed: 11/11/2022]
Abstract
A method to determine 8 polychlorinated biphenyls (PCBs), 23 organochlorine pesticides (OCPs) and 16 polycyclic aromatic hydrocarbons (PAHs) was described using dispersive liquid-liquid microextraction (DLLME) of a small amount of plasma or serum sample and gas chromatography-tandem mass spectrometry (GC-MS/MS). The appropriate selection of the extraction solvent and dispersing solvent contributes to a high extraction yield and a clean extract. To verify the developed method, the interference, linearity of the calibration curve, detection limit, precision and accuracy were evaluated. The calibration curves were linear by 2-3 orders of magnitude with correlation coefficients above 0.997 in all cases. The LODs of PCBs, OCPs and PAHs were measured in the ranges of 0.0006-0.0029, 0.001-0.029 and 0.0002-0.012 ng/ml. The intraday precision achieved by this method was 2.19-10.3% (PCBs), 1.65-14.3% (OCPs) and 0.91-12.8% (PAHs), and the intraday accuracy 1.56-7.37% (PCBs), 2.34-19.6% (OCPs) and 1.49-15.7% (PAHs). The advantage of this method is that the analysis of PCBs, OCPs, and PAHs can be performed in a single chromatographic run, and the low detection limit enables monitoring of target substances in low exposure general public samples, and the analysis procedure is relatively simple and fast.
Collapse
|
5
|
Altered Steroidome in Women with Gestational Diabetes Mellitus: Focus on Neuroactive and Immunomodulatory Steroids from the 24th Week of Pregnancy to Labor. Biomolecules 2021; 11:biom11121746. [PMID: 34944390 PMCID: PMC8698588 DOI: 10.3390/biom11121746] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2021] [Revised: 11/12/2021] [Accepted: 11/20/2021] [Indexed: 12/19/2022] Open
Abstract
Gestational diabetes mellitus (GDM) is a complication in pregnancy, but studies focused on the steroidome in patients with GDM are not available in the public domain. This article evaluates the steroidome in GDM+ and GDM- women and its changes from 24 weeks (± of gestation) to labor. The study included GDM+ (n = 44) and GDM- women (n = 33), in weeks 24-28, 30-36 of gestation and at labor and mixed umbilical blood after delivery. Steroidomic data (101 steroids quantified by GC-MS/MS) support the concept that the increasing diabetogenic effects with the approaching term are associated with mounting progesterone levels. The GDM+ group showed lower levels of testosterone (due to reduced AKR1C3 activity), estradiol (due to a shift from the HSD17B1 towards HSD17B2 activity), 7-oxygenated androgens (competing with cortisone for HSD11B1 and shifting the balance from diabetogenic cortisol towards the inactive cortisone), reduced activities of SRD5As, and CYP17A1 in the hydroxylase but higher CYP17A1 activity in the lyase step. With the approaching term, the authors found rising activities of CYP3A7, AKR1C1, CYP17A1 in its hydroxylase step, but a decline in its lyase step, rising conjugation of neuroinhibitory and pregnancy-stabilizing steroids and weakening AKR1D1 activity.
Collapse
|
6
|
Comparison of EI-GC-MS/MS, APCI-LC-MS/MS, and ESI-LC-MS/MS for the Simultaneous Analysis of Nine Nitrosamines Eluted from Synthetic Resins into Artificial Saliva and Health Risk Assessment. TOXICS 2021; 9:230. [PMID: 34678926 PMCID: PMC8540041 DOI: 10.3390/toxics9100230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 09/08/2021] [Accepted: 09/20/2021] [Indexed: 12/01/2022]
Abstract
Nitrosamines can be produced during the manufacture of rubber-type products such as pacifiers or the nipples of baby bottles. Humans can be exposed to the nitrosamines in these products when they are eluted into saliva. In this study, we compared the efficiency of electron impact ionization (EI), atmospheric pressure chemical ionization (APCI), and electrospray ionization (ESI) methods for the analysis of nine nitrosamines eluted into artificial saliva. In addition, nine nitrosamines eluted from 54 rubber-type products (rubber, thermoplastic elastomer, thermoplastic polyurethane, and polyurethane) marketed in Korea were monitored. Finally, non-carcinogenic and carcinogenic risk assessments of oral exposure to nine nitrosamines were performed based on the monitoring results. EI-GC-MS/MS performed the best for the simultaneous analysis of these nine nitrosamines with respect to overall linearity, trace analysis limit of detection (less than 1 μg), recovery (average 108.66 ± 9.32%), and precision (less than 6%), compared with liquid chromatography-tandem mass spectrometry (LC-MS/MS) (APCI and ESI) methods. Using the EI-GC-MS/MS method, these nine nitrosamines eluted into artificial saliva from 54 rubber-type products were monitored. Based on the monitoring data, risk assessment was performed by calculating the margin of exposure (MOE) for the respective nitrosamines detected. As a result, these nitrosamines were confirmed to be safe with regard to both non-carcinogenic and carcinogenic risks.
Collapse
|
7
|
Gas Chromatography-Tandem Mass Spectrometry Method for the Selective Detection of Glycols and Glycerol in the Liquids and Aerosols of E-Cigarette, or Vaping, Products. Front Chem 2021; 9:709495. [PMID: 34414162 PMCID: PMC8369378 DOI: 10.3389/fchem.2021.709495] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2021] [Accepted: 07/20/2021] [Indexed: 11/13/2022] Open
Abstract
The long-term health effects of using e-cigarette, or vaping, products (EVPs; also known as e-cigarettes, electronic nicotine delivery systems, and vape pens) remain largely unknown. The inhalation of excipients, such as propylene glycol (PG) and glycerin (GLY), may have long-term health effects. In addition to the direct health effects of PG and GLY, glycerin-containing products can be contaminated with toxic ethylene glycol (EG) and diethylene glycol (DEG). To assess this issue, we developed a simple, versatile, high-throughput isotope dilution gas chromatography-tandem mass spectrometry method for quantifying these common excipients and contaminants. The method is applicable to both the liquid contents and machine-generated aerosols of EVPs. Our rigorous method validation demonstrates that the new method is specific, precise, accurate, and rugged/robust. The calibration range is linear from 0.1–7 mg for the excipients and 2.5–1,000 µg for the contaminants. These ranges encompass expected excipients levels in EVP e-liquids and their machine-generated aerosols and the relevant maximum residue safety limit of 1 mg/g, or 0.1% (w/w), for the contaminants. The calculated limits of detection for PG, GLY, EG, and DEG were determined as 0.0109 mg, 0.0132 mg, 0.250 µg, and 0.100 µg, respectively. The method was applied to the aerosol emissions analysis of 141 EVPs associated with the 2019 lung injury outbreak, and found typical levels of PG (120.28–689.35 mg/g of aerosol) and GLY (116.83–845.96 mg/g of aerosol) in all nicotine-containing products; PG (81.58–491.92 mg/g of aerosol) and GLY (303.86–823.47 mg/g of aerosol) in 13% of cannabidiol (CBD) products; PG (74.02–220.18 mg/g of aerosol) and GLY (596.43–859.81 mg/g of aerosol) in products with neither nicotine nor CBD; and none detected in tetrahydrocannabinol (THC) products. No products contained glycol contaminants above the recommended maximum residue safety limit.
Collapse
|
8
|
Development of a Method for Simultaneous Analysis of Allergenic Flavoring Agents in Cigarettes and Quantitative Risk Assessment for Consumer Safety. TOXICS 2021; 9:toxics9040087. [PMID: 33919504 PMCID: PMC8072964 DOI: 10.3390/toxics9040087] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 04/02/2021] [Accepted: 04/16/2021] [Indexed: 11/17/2022]
Abstract
Flavoring agents are added to cigarettes to improve taste. There are mostly permitted food additives, but some of them are restricted for use in food, cosmetics, and toys, since they can cause allergic reactions. Previous studies have investigated the levels of flavoring agents in tobacco but none has focused on their content in filter tips and capsules. Moreover, no studies have assessed the risk of adding allergenic flavoring agents in cigarettes. Here, we developed and validated a simultaneous analysis method for 25 allergenic flavoring agents and menthol with gas chromatography–tandem mass spectrometry to determine levels of flavoring agents in the tobacco, filter tips, and capsules of 54 commercial cigarettes in Korea. All cigarettes contained at least one allergenic flavoring agent regardless of the inclusion of flavoring capsules. Importantly, the filter tips and the capsules contained higher levels of flavoring agents than tobacco, highlighting the importance of the quantification of flavoring agents in these parts of cigarettes. Nevertheless, the risk assessment based on their levels in cigarettes suggested that their exposure was maintained at a safe level. However, the risk assessed from maximum menthol, linalool, and cinnamaldehyde exceeded one-tenth of derived no-effect levels, suggesting the need for further studies on their risk to human health.
Collapse
|
9
|
Metabolic Profiling of the Cerebrospinal Fluid in Pediatric Epilepsy. ACTA MEDICA OKAYAMA 2020; 74:65-72. [PMID: 32099251 DOI: 10.18926/amo/57955] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
To characterize metabolic profiles within the central nervous system in epilepsy, we performed gas chromatography-tandem mass spectrometry (GC-MS/MS)-based metabolome analysis of the cerebrospinal fluid (CSF) in pediatric patients with and without epilepsy. The CSF samples obtained from 64 patients were analyzed by GC-MS/MS. Multivariate analyses were performed for two age groups, 0-5 years of age and 6-17 years of age, to elucidate the effects of epilepsy and antiepileptic drugs on the metabolites. In patients aged 0-5 years (22 patients with epilepsy, 13 without epilepsy), epilepsy patients had reduced 2-ketoglutaric acid and elevated pyridoxamine and tyrosine. In patients aged 6-17 years (12 with epilepsy, 17 without epilepsy), epilepsy patients had reduced 1,5-anhydroglucitol. Valproic acid was associated with elevated 2-aminobutyric acid, 2-ketoisocaproic acid, 4-hydroxyproline, acetylglycine, methionine, N-acetylserine, and serine. Reduced energy metabolism and alteration of vitamin B6 metabolism may play a role in epilepsy in young children. The roles of 1,5-anhydroglucitol in epilepsy in older children and in levetiracetam and zonisamide treatment remain to be explained. Valproic acid influenced the levels of amino acids and related metabolites involved in the metabolism of serine, methionine, and leucine.
Collapse
|
10
|
Metabolomics Study of Serum from a Chronic Alcohol-Fed Rat Model Following Administration of Defatted Tenebrio molitor Larva Fermentation Extract. Metabolites 2020; 10:metabo10110436. [PMID: 33138187 PMCID: PMC7693418 DOI: 10.3390/metabo10110436] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Revised: 10/22/2020] [Accepted: 10/27/2020] [Indexed: 12/11/2022] Open
Abstract
We have previously showed that defatted mealworm fermentation extract (MWF) attenuates alcoholic liver injury by regulating lipid, inflammatory, and antioxidant metabolism in chronic alcohol-fed rats. The current metabolomics study was performed to monitor biochemical events following the administration of MWF (daily for eight weeks) to a rat model of alcoholic liver injury by gas chromatography-tandem mass spectrometry (GC-MS/MS). The levels of 15 amino acids (AAs), 17 organic acids (OAs), and 19 free fatty acids (FFAs) were measured in serum. Analysis of variance (ANOVA), principal component analysis (PCA), and partial least squares discriminant analysis (PLS-DA) were used to compare the levels of 51 metabolites in serum. In particular, 3-hydroxybutyric acid (3-HB), pyroglutamic acid (PG), octadecanoic acid, and docosahexaenoic acid (DHA) were evaluated as high variable importance point (VIP) scores and PCA loading scores as determined by PLS-DA and PCA, and these were significantly higher in the MWF and silymarin groups than in the EtOH group. MWF showed a protective effect from alcohol-induced liver damage by elevating hepatic β-oxidation activity, and serum 3-HB levels were significantly higher in the MWF group than in the EtOH control group. Glycine levels were higher in the MWF group than in the EtOH group, and PG levels (related to glutathione production) were also elevated, indicating a reduction in alcohol-related oxidative stress. In addition, MWF is protected from alcohol-induced inflammation and steatosis by increasing serum DHA, palmitic, and octadecanoic acid levels as compared with the EtOH group. These results suggest that MWF might attenuate alcoholic liver disease, due to its anti-inflammatory and antioxidant effects by up-regulating hepatic β-oxidation activity and down-regulating liver FFA uptake.
Collapse
|
11
|
[Screening and confirmation of pesticide residues in substitutional tea such as orange peel, lotus leaf, pueraria lobata and Pangdahai]. WEI SHENG YAN JIU = JOURNAL OF HYGIENE RESEARCH 2020; 49:815-822. [PMID: 33070829 DOI: 10.19813/j.cnki.weishengyanjiu.2020.05.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
OBJECTIVE The screening method was established for pesticide residues in substitutional teas such as orange peel, lotus leaf, pueraria lobata and Pangdahai using data base. The method for analyzing of 26 pesticide residues was confirmed in four substitutional teas with gas chromatography-tandem mass spectrometry(GC-MS/MS) and dispersive solid-phase extraction(d-SPE) for sample preparation. METHODS The 26 types of pesticides were selected as target compounds, including screened out, commonly used in substitutional tea planting and forbidden in agriculture planting. The samples extracted with acetonitrile, and purified by adsorbent(e. g PSA, GCB, C_(18)), the purification solutions were separated on DB-5 MS UI column((15 m+PUU+15 m)×0. 25 mm×0. 25 μm) with programmed temperature and determined by GC-MS/MS in multi-reaction monitoring(MRM) model. The external standard method was applied to quantify the pesticides. RESULTS The method showed a good linearity(r≥0. 995)in concentration range(2-100 μg/L) for 26 kinds of pesticides. The limits of quantification(LOQ) were 3-40 μg/kg. The average recoveries range were 71. 9%-114. 4% in three add levels of 10, 50, 200 μg/kg, and relative standard deviations of 1. 0%-16. 0%(n=6). In the four matrixes, the pesticides were detected concentrating on orange peel, and there were kinds of residues. CONCLUSION This method is simple, fast, sensitive, selective and can satisfy the request of pesticide screening and simultaneous analysis of multiple pesticide residues in orange peel, lotus leaf, pueraria lobata and Pangdahai.
Collapse
|
12
|
Fabric phase sorptive extraction for the determination of 17 multiclass fungicides in environmental water by gas chromatography-tandem mass spectrometry. J Sep Sci 2020; 43:1817-1829. [PMID: 31958358 DOI: 10.1002/jssc.201901232] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 01/13/2020] [Accepted: 01/14/2020] [Indexed: 11/08/2022]
Abstract
A rapid environmental pollution screening and monitoring workflow based on fabric phase sorptive extraction-gas chromatography-tandem mass spectrometry (FPSE-GC-MS/MS) is proposed for the first time for the analysis of 17 widespread used fungicides (metalaxyl, cyprodinil, tolylfluanid, procymidone, folpet, fludioxonil, myclobutanil, kresoxim methyl, iprovalicarb, benalaxyl, trifloxystrobin, fenhexamid, tebuconazole, iprodione, pyraclostrobin, azoxystrobin and dimethomorph) in environmental waters. The most critical parameters affecting FPSE, such as sample volume, matrix pH, desorption solvent and time, and ionic strength were optimized by statistical design of experiment to obtain the highest extraction efficiency. Under the optimized conditions, the proposed FPSE-GC-MS/MS method was validated in terms of linearity, repeatability, reproducibility, accuracy and precision. To assess matrix effects, recovery studies were performed employing different water matrices including ultrapure, fountain, river, spring, and tap water at 4 different concentration levels (0.1, 0.5, 1 and 5 µg/L). Recoveries were quantitative with values ranging between 70-115%, and relative standard deviation values lower than 14%. Limits of quantification were at the low ng/L for all the target fungicides. Finally, the validated FPSE-GC-MS/MS method was applied to real water samples, revealing the presence of 11 out of the 17 target fungicides.
Collapse
|
13
|
Determination of d-limonene in mice plasma and tissues by a new GC-MS/MS method: Comparison of the pharmacokinetics and tissue distribution by oral and inhalation administration in mice. Biomed Chromatogr 2019; 33:e4530. [PMID: 30845345 DOI: 10.1002/bmc.4530] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Revised: 02/21/2019] [Accepted: 03/01/2019] [Indexed: 11/08/2022]
Abstract
The aim of the present study was to develop a method based on gas chromatography-tandem mass spectrometry (GC-MS/MS) to determine and quantify the d-limonene in mouse plasma and tissue samples. This new method was validated for the quantification of d-limonene with the linearity ranges 1.0-1000.0 ng/mL (r2 > 0.9952) for plasma samples and 5.0-5000.0 ng/g (r2 > 0.9940) for tissue samples. The intra- and inter-day assay of precisions in plasma and tissues were <13.4% and the accuracies were within 91.1-105.8%. In the oral/inhalation administration pharmacokinetics and tissue distribution studies, the main pharmacokinetic parameters were the peak concentration = (97.150 ± 34.450)/(4336.415 ± 1142.418) ng/mL, the area under the curve = (162.828± 27.447)/(2085.721 ± 547.787) h ng/mL and the half-life = (3.196 ± 0.825)/(0.989 ± 0.095) h. The tissue distribution of d-limonene in mice after oral/inhalation administration demonstrated a decreasing tendency in different tissues (liver > kidney > heart > lung > spleen).
Collapse
|
14
|
Simultaneous determination of sarcosine and its related metabolites by gas chromatography-tandem mass spectrometry for prostate cancer diagnosis. EXCLI JOURNAL 2018; 17:965-979. [PMID: 30564076 PMCID: PMC6295632 DOI: 10.17179/excli2018-1352] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/20/2018] [Accepted: 10/02/2018] [Indexed: 11/10/2022]
Abstract
Shortly after sarcosine was delineated as a potential biomarker for prostate cancer in 2009, a variety of analytical methods for clinical application were developed. Moreover, higher uptake of glycine in the mitochondria also played a role in cancer proliferation. A major constraint in the accurate quantification of sarcosine was the interference of the two isomers, α-alanine and β-alanine, using chromatographic separation techniques. Accordingly, we aimed to develop an analytical method for determining sarcosine and its related metabolites (α- and β-alanine, glycine and creatinine) under the same conditions by gas chromatography-tandem mass spectrometry (GC-MS/MS). BSTFA + 1 % TMCS was used for silylation, and GC-MS/MS conditions were optimized for the target analytes. The unique transition ions of sarcosine, α- and β-alanine, glycine and creatinine set up in MRM acquisition were m/z 116 → 73, 190 → 147, 176 → 147, 176 → 147 and 100 → 73, respectively. This newly developed method was successfully validated to apply in clinical settings with low limits of detection (0.01 - 0.03 µg•mL-1), high correlations (R2 > 0.99), great accuracy (88 - 110 % recovery), and notable precision (RSD < 10 %). All TMS derivatives were > 80 % stable for up to 2 h after derivatization and analyzing during this period promises to achieve an accurate result. Monitoring the five-substance profile could enhance prospects for early diagnosis of prostate cancer.
Collapse
|
15
|
Simultaneous determination of organochlorine and pyrethriod pesticide residues in the Chinese patent medicines by gas chromatography-tandem mass spectrometry. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART. B, PESTICIDES, FOOD CONTAMINANTS, AND AGRICULTURAL WASTES 2018; 53:126-134. [PMID: 29227209 DOI: 10.1080/03601234.2017.1387026] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
A simple, sensitive, reliable method was developed for the simultaneous determination of organochlorine and pyrethriod pesticide residues in Chinese patent medicines Six ingredient rehmannia pills and Xiaoyao pills. These pesticides were extracted by ethyl acetate. The extraction time and volume of ethyl acetate were optimized. Cleanup of extracts was performed with dispersive-solid phase extraction using graphitized carbon black as the sorbent. The determination of pesticides in the final extracts was carried out by gas chromatography-tandem mass spectrometry in multiple reaction monitoring mode (GC-MS/MS, MRM). The linearity of the calibration curves is good in matrix-matched standard and yields the coefficients of determination (R2) ≥0.99 for all of the target analytes. Under optimized conditions, the average recoveries (five replicates) for most pesticides range from 75.5% to 114.6%, and RSDs are less than 10.0%. The LODs of 18 pesticides in Six ingredient rehmannia pill and Xiaoyao pills are in the range of 0.01-8.82 μg kg-1. The developed method meets the requirements of pesticide residue analysis and could be effectively used for routine analysis of the organochlorine and pyrethriod pesticide residues in Six ingredient rehmannia pills and Xiaoyao pills.
Collapse
|
16
|
Sensitive and rapid determination of pyrethroids in human blood by gas chromatography-tandem mass spectrometry with ultrasound-assisted dispersive liquid-liquid microextraction. Drug Test Anal 2018; 10:1131-1138. [PMID: 29350497 DOI: 10.1002/dta.2358] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Revised: 01/02/2018] [Accepted: 01/03/2018] [Indexed: 12/29/2022]
Abstract
In this study, a sensitive and fast procedure of ultrasonic-assisted dispersive liquid-liquid microextraction (UADLLME) coupled with gas chromatography-tandem mass spectrometry (GC-MS/MS) for the determination of major pyrethroid pesticides (permethrin, tetramethrin, bifenthrin, fenvalerate, flucythrinate, fluvalinate, fenpropathrin, deltamethrin, and cyhalothrin) in blood samples was developed. Response surface methodology (RSM) combined with Box-Behnken design (BBD) and ANOVA function was used to optimize key factors affecting the extraction efficiency of UADLLME procedure. Target compounds were analyzed by GC-MS/MS. Under the optimal conditions, good linearity (R2 >0.99) was achieved for all the analytes in the concentration range of 0.5 to 100 μg L-1 . The recoveries for spiked samples at 3 concentration levels were between 70.2 and 91.8%, with relative standard deviations (RSD) lower than 10%. Very low limits of detection (LODs) and limits of quantification (LOQs) ranging from 0.01 to 0.1 μg L-1 and from 0.03 to 0.3 μg L-1 were achieved. This method was successfully applied to the determination of low concentration of pyrethroids in blood samples from real forensic cases. High sensitivity, fast determination, simplicity in operation, small sample volume, and low usage of organic solvents are the advantages of this method. This methodology is of important value for sensitive and quick determination of residue pesticides and metabolites, study of residue pesticides behavior in human body, as well as application in real forensic cases.
Collapse
|
17
|
GC-MS/MS method for the determination and pharmacokinetic analysis of borneol and muscone in rat after the intravenous administration of Xingnaojing injection. J Sep Sci 2017; 40:4264-4271. [PMID: 28834206 DOI: 10.1002/jssc.201700341] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Revised: 08/09/2017] [Accepted: 08/13/2017] [Indexed: 01/31/2023]
Abstract
A simple and sensitive gas chromatography with tandem mass spectrometry method was developed and validated for the simultaneous determination of borneol and muscone in rat plasma. The analytes and internal standard, naphthalene, were extracted using a convenient one-step liquid-liquid extraction method with ethyl acetate. The chromatographic separation was realized on a HP-5MS capillary column and detected in multiple reaction monitoring mode. Excellent linearity (R2 ≥ 0.996) was shown over 10.0-5000 ng/mL for borneol and 2.5-250 ng/mL for muscone. The lower limit of quantitation was 10 and 2.5 ng/mL for borneol and muscone, respectively. The intra- and interday precisions were less than 7.52%, and the accuracy values were between -8.03 and 14.52%. The extraction recovery, matrix effect, and stability were sufficient to meet the Food and Drug Administration criteria. Meanwhile, the assay was successfully applied to the preclinical pharmacokinetic study of borneol and muscone following intravenous administration of Xingnaojing injection, a modern Chinese herbal medicine preparation.
Collapse
|
18
|
Simultaneous determination of eight metabolites of organophosphate and pyrethroid pesticides in urine. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART. B, PESTICIDES, FOOD CONTAMINANTS, AND AGRICULTURAL WASTES 2017; 52:1-9. [PMID: 27629156 DOI: 10.1080/03601234.2016.1224695] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A simultaneous method for quantifying eight metabolites of organophosphate pesticides and pyrethroid pesticides in urine samples has been established. The analytes were extracted using liquid-liquid extraction coupled with WCX solid phase extraction (SPE) cartridges. Eight metabolites were chemically derivatized before analysis using gas chromatography-tandem mass spectrometry (GC-MS-MS). The separation was performed on a HP-5MS capillary column (30 m × 0.25 mm × 0.25 µm) with temperature programming. The detection was performed under electro-spray ionization (ESI) in multiple reaction monitoring (MRM) mode. An internal standard method was used. The extraction solvent, types of SPE cartridges and eluents were optimized by comparing the sample recoveries under different conditions. The results showed that the calibration curves of the five organophosphorus pesticides metabolites were linear in the range of 0.2-200 μg/L (r2 ≥ 0.992) and that of the three pyrethroid pesticides metabolites were linear in the range of 0.025-250 μg/L (r2 ≥ 0.991). The limits of detection (LODs, S/N ≥ 3) and the limits of quantification (LOQs, S/N ≥ 10) of the eight metabolites were 0.008-0.833 μg/L and 0.25-2.5 μg/L, respectively. The recoveries of the eight metabolites ranged from 54.08% to 82.49%. This efficient, stable, and cost-effective method is adequate to handle the large number of samples required for surveying the exposure level of organophosphorus and pyrethroid pesticides in the general population.
Collapse
|
19
|
Monitoring the concentrations of nonsteroidal anti-inflammatory drugs and cyclooxygenase-inhibiting activities in the surface waters of the Tone Canal and Edo River Basin. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH. PART A, TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING 2015; 50:1108-1115. [PMID: 26191985 DOI: 10.1080/10934529.2015.1047647] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Environmental pollution by pharmaceuticals has become a major problem in many countries worldwide. However, little is known about the concentrations of pharmaceuticals in water sources in Japan. The objective of this study was to clarify variations in the concentrations of seven nonsteroidal anti-inflammatory drugs (NSAIDs) and in cyclooxygenase(COX)-inhibiting activities in river water and domestic wastewater collected from the Tone Canal and the Edo River Basin in Japan. Total NSAID concentrations were higher in the Tone Canal than in the Edo River, and the highest concentration was observed at the domestic wastewater inflow point located in the Tone Canal (concentration averages of salicylic acid, ibuprofen, felbinac, naproxen, mefenamic acid, diclofenac, and ketoprofen in wastewater samples were 55.3, 162.9, 39.7, 11.8, 30.8, 259.7, and 48.3 ng L(-1), respectively). Gas chromatography-tandem mass spectrometry showed that wastewater samples collected during cooler seasons contained higher levels of COX-inhibiting activity. COX-inhibiting activities were highly correlated with NSAID concentrations (particularly for ketoprofen and diclofenac); however, other COX inhibitors, such as NSAIDs that were not examined in this study and/or other chemicals with COX-inhibiting activity, could exist in the water samples because the concentrations of NSAIDs obtained from the water samples did not account for the total COX-inhibiting activities observed. Therefore, COX inhibition assays may be helpful for evaluating the aquatic toxicity of COX inhibitors. In this study, we demonstrated that COX inhibitors in surface water may influence aquatic organisms more than was expected based on NSAID concentrations. Thus, further studies examining other COX inhibitors in the aquatic environment are necessary.
Collapse
|
20
|
Simultaneous determination of polybrominated diphenyl ethers and polychlorinated biphenyls by gas chromatography-tandem mass spectrometry in human serum and plasma. Talanta 2013; 113:41-8. [PMID: 23708622 PMCID: PMC3698050 DOI: 10.1016/j.talanta.2013.04.001] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2013] [Revised: 03/29/2013] [Accepted: 04/01/2013] [Indexed: 12/31/2022]
Abstract
Sensitive and reliable methods for simultaneous determination of polybrominated diphenyl ethers (PBDEs) and polychlorinated biphenyls (PCBs) in limited volumes of human serum or plasma need to be further documented especially when they accumulate at low levels that are still capable of disrupting endocrine and immune functions, and affecting neurodevelopment and reproduction. The objective of this study was to develop and validate a sensitive and quantitative method that simultaneously quantifies PBDEs and PCBs in 0.5 ml of human serum or plasma. We optimized a solid-phase extraction (SPE) method and used silica particle purification for the extraction of PBDEs and PCBs. Two multiple reactions monitoring (MRM) transitions were optimized for each congener. The sum of the transitions was used for quantification, and their abundance ratios were used for identification. The combined method optimization techniques resulted in limits of detection from 3 to 145 pg/ml for 10 PBDEs and 1-12 pg/ml for 15 PCBs. Method was solidly validated by analyzing serum fortified with a certified PBDE and PCB standard mixture from the National Institute of Standards and Technology (NIST). The accuracy was 88-118% and day-to-day precision was within 19%. The method was successfully applied to quantify native concentrations of PBDE and PCB in commercially available human serum. The sensitivity and selectivity of the GC/EI-MS/MS analysis enables it to be the method of choice for investigations of exposures to PBDE and PCB congeners, especially when sample volume is limited.
Collapse
|
21
|
Fatal case of a 27-year-old male after taking iboga in withdrawal treatment: GC-MS/MS determination of ibogaine and ibogamine in iboga roots and postmortem biological material. J Forensic Sci 2013; 58:1666-72. [PMID: 23919354 DOI: 10.1111/1556-4029.12250] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2011] [Revised: 06/27/2012] [Accepted: 09/03/2012] [Indexed: 11/27/2022]
Abstract
We report the case of a man who died twelve hours after ingesting powdered iboga root, commonly taken for its stimulant and hallucinogenic properties. Ibogaine and ibogamine were quantified in the powder ingested and the victim's body fluids by GC-MS/MS after liquid-liquid extraction (Toxi-tubes A(®)). The concentrations of ibogaine measured in the blood samples taken at the scene and in the peripheral blood, urine, and gastric fluid samples taken during the autopsy were 0.65, 1.27, 1.7, and 53.5 μg/mL, while the iboga content in the powder was 7.2%. Moreover, systematic toxicological analyses of biological samples showed the presence of diazepam and methadone in therapeutic concentrations. Death was attributed to the ingestion of a substantial quantity of iboga in the context of simultaneous methadone and diazepam consumption.
Collapse
|