1
|
Assessing the Effects and Challenges of Total Hip Arthroplasty before Pregnancy and Childbirth: A Systematic Review. J Funct Morphol Kinesiol 2024; 9:63. [PMID: 38651421 PMCID: PMC11036194 DOI: 10.3390/jfmk9020063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/19/2024] [Revised: 03/31/2024] [Accepted: 04/02/2024] [Indexed: 04/25/2024] Open
Abstract
Total hip arthroplasty is indubitably one of the most performed operations worldwide. On the other hand, especially in the western world, the average age that women get pregnant has raised confoundedly. Consequently, a steadily increasing number of women become pregnant after they had hip arthroplasty surgery, with copious potential implications. The amount of knowledge on this particular field is considered inadequate in the existing literature. This paper aims to augment clinicians understanding surrounding this topic. A systematic literature review was conducted in accordance with the PRISMA guidelines. Papers from various computerized databases were scrutinized. Article selection was carried out by three authors independently employing specific pre-determined inclusion and exclusion criteria, while disagreements were elucidated with the contribution of other authors. A patently limited number of research articles were detected from our rigorous literature review, with only 12 papers meeting the inclusion criteria. The vast majority of studies were small-scale and examined confined population groups. Most studies had been performed in Finland, utilizing data from nationwide registries. Women with previous history of total hip arthroplasty feature increased rates of c-section delivery, although vaginal labor can be attempted with certain precautions. Hip implants' survival does not appear to be affected from gestation, which is predominately well-tolerated from these women. Metal ion circulation in mothers' blood has not been proven to trigger substantial complications concerning either mothers or offspring. It can be considered safe for women with such medical history to get pregnant; however, further multinational studies and pertinent research on this field are vital to attain more solid inferences.
Collapse
|
2
|
Influence of Physical Activity and Cup Orientation on Metal Ion Release and Oxidative Stress in Metal-on-Metal and Ceramic-on-Metal Total Hip Arthroplasty. J Clin Med 2024; 13:527. [PMID: 38256664 PMCID: PMC10816639 DOI: 10.3390/jcm13020527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 12/30/2023] [Accepted: 01/16/2024] [Indexed: 01/24/2024] Open
Abstract
BACKGROUND Metal-on-metal (M-M) total hip arthroplasty (THA) has shown adverse reactions to metal debris, abnormal soft-tissue reactions, and high blood metal ion levels. This study aims to: (1) assess whether the toxicity of high levels of ions is related to altered oxidative stress and (2) evaluate tribological factors related to increased blood levels of chromium (Cr) and cobalt (Co) ions. METHODS A cross-sectional analytical descriptive study was conducted on 75 patients. A total of 25 underwent M-M THA, 25 ceramic-on-metal (C-M) THA, and 25 were on the THA waiting list. Ion metallic levels in blood, oxidative stress, physical activity, and implant position were compared. RESULTS In the M-M group, Co and Cr levels were significantly higher than those found in the C-M group and the control group (p < 0.01). We found no differences in terms of oxidative stress between the groups. Also, we did not find a correlation between metal blood levels and oxidative stress indicators, the physical activity of the patients or the position of the implants between groups. CONCLUSIONS The use of M-M bearing surfaces in THA raises the levels of metals in the blood without modifying oxidative stress regardless of the physical activity levels of the patients. Therefore, although patients with M-M bearings require close monitoring, it does not seem necessary to recommend the restriction of physical activity in patients with M-M or C-M arthroplasties.
Collapse
|
3
|
Survivorship and risk factors for revision of metal-on-metal hip resurfacing. Bone Jt Open 2023; 4:853-858. [PMID: 37944559 PMCID: PMC10635743 DOI: 10.1302/2633-1462.411.bjo-2023-0084.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2023] Open
Abstract
Aims Metal-on-metal hip resurfacing (MoM-HR) has seen decreased usage due to safety and longevity concerns. Joint registries have highlighted the risks in females, smaller hips, and hip dysplasia. This study aimed to identify if reported risk factors are linked to revision in a long-term follow-up of MoM-HR performed by a non-designer surgeon. Methods A retrospective review of consecutive MoM hip arthroplasties (MoM-HRAs) using Birmingham Hip Resurfacing was conducted. Data on procedure side, indication, implant sizes and orientation, highest blood cobalt and chromium ion concentrations, and all-cause revision were collected from local and UK National Joint Registry records. Results A total of 243 hips (205 patients (163 male, 80 female; mean age at surgery 55.3 years (range 25.7 to 75.3)) with MoM-HRA performed between April 2003 and October 2020 were included. Mean follow-up was 11.2 years (range 0.3 to 17.8). Osteoarthritis was the most common indication (93.8%), and 13 hips (5.3%; 7M:6F) showed dysplasia (lateral centre-edge angle < 25°). Acetabular cups were implanted at a median of 45.4° abduction (interquartile range 41.9° - 48.3°) and stems neutral or valgus to the native neck-shaft angle. In all, 11 hips (4.5%; one male, ten females) in ten patients underwent revision surgery at a mean of 7.4 years (range 2.8 to 14.2), giving a cumulative survival rate of 94.8% (95% confidence interval (CI) 91.6% to 98.0%) at ten years, and 93.4% (95% CI 89.3% to 97.6%) at 17 years. For aseptic revision, male survivorship was 100% at 17 years, and 89.6% (95% CI 83.1% to 96.7%) at ten and 17 years for females. Increased metal ion levels were implicated in 50% of female revisions, with the remaining being revised for unexplained pain or avascular necrosis. Conclusion The Birmingham MoM-HR showed 100% survivorship in males, exceeding the National Institute for Health and Care Excellence '5% at ten years' threshold. Female sex and small component sizes are independent risk factors. Dysplasia alone is not a contraindication to resurfacing.
Collapse
|
4
|
Synovial Fluid Metal Ion Levels are Superior to Blood Metal Ion Levels in Predicting an Adverse Local Tissue Reaction in Failed Total Hip Arthroplasty. J Arthroplasty 2021; 36:3312-3317.e1. [PMID: 34030874 PMCID: PMC9376798 DOI: 10.1016/j.arth.2021.04.034] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 04/21/2021] [Accepted: 04/26/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Adverse local tissue reactions (ALTR) are associated with total hip arthroplasty (THA) failure in patients with metal-on-metal bearings and/or taper corrosion, which can also occur in metal-on-polyethylene articulations. Patients are monitored with blood cobalt (Co) and chromium (Cr) concentrations which do not always correlate with the degree of soft tissue reaction at revision THA. The purpose of this study was to determine how the blood and prosthetic hip synovial fluid levels of Co and Cr correlate with one another, and determine which concentration is more predictive of ALTR. METHODS Synovial fluid and blood samples were collected at the time of revision THA in patients with (n = 26) and without ALTR (n = 27). Whole blood, serum, and synovial fluid metal ion concentrations were correlated with one another and clinical findings. RESULTS The ratio of synovial fluid to whole blood Co concentration in ALTR and non-ALTR hips was 120:1 and 18:1 (P = .006). The mean ratio of synovial fluid to whole blood Cr concentration in ALTR and non-ALTR hips was 414:1 and 24:1 (P = .01). The mean synovial fluid Co/Cr concentrations were elevated in patients with ALTR compared with those without (2007.3 vs. 12.4 ppb, P = .007) and (3188.2 vs. 10.3 ppb, P = .02). The synovial fluid Co concentration was the most accurate test for detecting ALTR (cut off: 19.75 PPB, AUC 0.973). CONCLUSION In patients with ALTR, synovial fluid Co and Cr levels were 120 times higher and 414 times higher than whole blood Co and Cr levels. Synovial fluid Co ion concentration was the most accurate in predicting ALTR. LEVEL OF EVIDENCE Diagnostic level II.
Collapse
|
5
|
Long Term Performance of an Uncemented, Proximally Hydroxyapatite Coated, Double Tapered, Titanium-Alloy Femoral Stem: Results From 1465 Hips at 10 years Minimum Follow-Up. J Arthroplasty 2021; 36:616-622. [PMID: 32896438 DOI: 10.1016/j.arth.2020.08.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 07/14/2020] [Accepted: 08/06/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND We assessed the survivorship of a proximally hydroxyapatite coated, double tapered, titanium-alloy femoral stem in a single center, at an average follow up of 12.5 years (10.1-15.8). The majority of stems were inserted as part of a Metal on Metal (MoM) Total Hip Replacement (THR). METHODS Data was collected prospectively in a local database. A retrospective review was performed of all patients undergoing a primary THR with the prosthesis between 2003 and 2010. Primary outcome was revision of the stem for any cause. Analysis was also performed for stem revision for aseptic loosening, stem revision in the MoM setting and a worst case scenario whereby lost to follow up were presumed to have failed. True stem failure was considered if revision occurred for a stem related complication. RESULTS 1465 stems were included (1310 patients, 155 bilateral). The bearing surface was cobalt chrome on cobalt chrome in 1351 cases (92%). Seven hips were lost to follow up. Thirty-two stems (31 part of a MoM THR) underwent revision for any cause. Kaplan Meier survival analysis demonstrates an overall 97.4% survivorship. Subset analysis demonstrates 100% survivorship for aseptic loosening, 97.3% in the MoM setting and 96.7% for the worst case senario. Of the 32 cases of stem revision, only 13 were classified as 'true' stem failure. CONCLUSION This study represents the largest cohort of this uncemented femoral component with a minimum follow-up longer than 10 years. Our results demonstrate excellent long-term survivorship even in the presence of a challenging MoM environment.
Collapse
|
6
|
Metal on Metal Bearing in Total Hip Arthroplasty and Its Impact on Synovial Cell Count. J Clin Med 2020; 9:jcm9103349. [PMID: 33081071 PMCID: PMC7603093 DOI: 10.3390/jcm9103349] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Revised: 10/15/2020] [Accepted: 10/16/2020] [Indexed: 12/27/2022] Open
Abstract
INTRODUCTION The effect of different bearings on synovial white blood cell (WBC) count and polymorphonuclear percentage (PMN%) in aspirations remains unclear. Therefore, this study investigates the impact of aseptic Metal-on-Metal (MoM) bearing on synovial fluid. METHODS We searched our arthroplasty registry for aseptic painful THAs with MoM bearings between 2011 and 2018. Then, a case-matched control group was selected with septic and aseptic Total Hip Arthroplasty (THA) with ceramic on a polyethylene (PE) bearing. The matching criteria consisted of gender, age +/-10 years, and time of aspiration (+/-2years). Periprosthetic Joint Infection (PJI) was defined according to the Infectious Diseases Society of America (IDSA), and Musculoskeletal Infection Society (MSIS) using bacterial cultures, sonication and histology. RESULTS In total, 19 patients who underwent hip aspiration with MoM bearing were identified. Five patients had to be excluded due to insufficient synovial fluid obtained (n = 2) or bacterial growth after sonication that was initially negative with the standard microbiological cultures (n = 3). As such, 14 were included. These patients were matched with 14 aseptic and 14 septic THAs with ceramic on a PE bearing, which constituted the control group. The mean serum chrome level was 20.0 ± 15.5 nmol/L and cobalt level 18.4 ± 22.1 nmol/L. The synovial WBC and PMN% varied significantly between MoM bearing group and the aseptic THA ceramic PE group (both p < 0.001), as well as the septic THA group (WBC p = 0.016, PMN% p < 0.001). Furthermore, the septic THA group had significantly higher CRP values than the aseptic MoM group (p = 0.016). CONCLUSION MoM bearing shows significantly higher synovial WBC and PMN% when compared to aseptic THA with ceramic on PE bearing above the MSIS cut-off. This is an important consideration when diagnosing periprosthetic joint infection using the MSIS guidelines.
Collapse
|
7
|
Early Cup Loosening After Metal-on-Metal Total Joint Replacement of the Trapeziometacarpal Joint: A Retrieval Study. J Hand Surg Am 2020; 45:213-222. [PMID: 31537396 DOI: 10.1016/j.jhsa.2019.06.020] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/18/2019] [Revised: 05/21/2019] [Accepted: 06/28/2019] [Indexed: 02/02/2023]
Abstract
PURPOSE To investigate the possible mechanisms behind early cup loosening in a metal-on-metal trapeziometacarpal joint replacement. METHODS The trapezia from 5 female patients were removed as part of a salvage procedure after a median of 22 months (range, 7-43 months) after implantation. Three osteoarthritic patients with symptomatic cup loosening and 2 with instability had a median age of 62 years (range, 59-65 years) at primary surgery. The trapezia with cups in situ were preserved and processed for histomorphometry. Studies with laser ablation inductively coupled plasma mass spectrometry and scanning electron microscopy with energy dispersive x-ray spectroscopy were also performed on 2 of the specimens. RESULTS In all 5 specimens, osteolytic lesions undermined the cups and were also seen at the cup edges, completely surrounding the loose cups. Large amounts of dark particular material were seen in the periprosthetic tissues, mostly internalized by macrophages. The presence of chrome and cobalt in these regions was confirmed. Four of the 5 cups showed marked or complete loss of hydroxyapatite. CONCLUSIONS We have found several possible explanations for the poor performance of this cup, including its cannulated design and metal-on-metal bearing. The changes seen are early and advanced, raising serious concerns about the implant and particularly the articulation. TYPE OF STUDY/LEVEL OF EVIDENCE Therapeutic V.
Collapse
|
8
|
Pseudotumor mimicking iliacus muscle abscess following a total hip arthoplasty with metal on metal articulation: A case report. Medicine (Baltimore) 2019; 98:e16322. [PMID: 31277178 PMCID: PMC6635227 DOI: 10.1097/md.0000000000016322] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
RATIONALE Cases of pseudotumor complicated after THA with metal-on-metal articulation as a bearing surface have been reported. Most of the pseudotumors occurred near or inside the hip joint, and usually have similar features with the infectious condition. We herein report a case of pseudotumor with huge size in the pelvic cavity mimicking features of iliacus muscle abscess. PATIENTS CONCERNS A 70-year-old female was referred to our emergency department due to huge mass in her right pelvic area on abdominal CT. She complained of mild febrile sensation, generalized weakness, and pain in her right leg for several months. The patient underwent metal-on-metal bearing THA 11 years ago for treatment of right-sided hip pain due to avascular necrosis. DIAGNOSIS Percutaneous catheter drainage was performed for both therapeutic and diagnostic reasons. No microbes were cultured from the drained fluid, and signs of chronic inflammation were shown on pathology slide samples. The patient showed positive allergic reactions to cobalt and captan on allergic patch test, and serum cobalt levels was increased as 46.78 μg/L (normal value, 0.11-0.64 μg/L). Biopsy samples of the cyst were consistent with the histological findings of pseudotumor reported by Willert et al. INTERVENTION:: For the treatment of infection, primarily, the patient was surgically treated by irrigation, debridement, and bone bead insertion. Then, after 4 weeks of antibiotic treatment, revision surgery changing the metal-on-metal articulation into poly-on-metal articulation was performed. OUTCOMES CT scan at 1 year after surgery showed no findings of cyst inside the pelvic cavity. Although the patient complained of right sided hip pain (VAS score 2), she was able to perform activities of daily living. LESSONS In patients who underwent metal-on-metal THA, pseudotumor mimicked the feature of periprosthetic infection may occur not only inside the hip joint but also in the pelvic cavity.
Collapse
|
9
|
Hip and Knee Section, Diagnosis, Algorithm: Proceedings of International Consensus on Orthopedic Infections. J Arthroplasty 2019; 34:S339-S350. [PMID: 30348566 DOI: 10.1016/j.arth.2018.09.018] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
|
10
|
Metal on Metal Hip Resurfacing in Patients 45 Years of Age and Younger at Minimum 5-Year Follow-Up. J Arthroplasty 2018; 33:3196-3200. [PMID: 29914818 DOI: 10.1016/j.arth.2018.05.041] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Revised: 04/19/2018] [Accepted: 05/28/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Metal on metal hip resurfacing (MoM-HR) is an alternative to total hip arthroplasty in young and active patients. The purpose was to determine the survivorship of MoM-HR procedures performed in patients aged 45 years and younger assessing patient-reported outcome measures (PROMs) at minimum 5-year follow-up. METHODS All 217 patients equal to or younger than 45 years of age at the time of surgical intervention presenting to our center with MoM-HR between May 2002 and May 2011 were prospectively followed. Baseline demographic data, preoperative and postoperative radiographic measurements, and validated PROMs were obtained (Hip Disability and Osteoarthritis Outcome Score, Western Ontario and McMaster Universities Osteoarthritis Index, and University of California, Los Angeles Activity Score). Survivorship was calculated using Kaplan-Meier analysis, and risk factors for failure were identified using multivariate regression analysis. RESULTS The overall survivorship excluding septic failures was 94.6% and 93.8% at 5 and 10 years, respectively. Aseptic loosening of the acetabular component was the most common mode of failure (11/20 cases). Gender, head size, and acetabular abduction angle had no significant effect on survivorship. Significant improvements in PROMs were seen for Hip Disability and Osteoarthritis Outcome Score, Western Ontario and McMaster Universities Osteoarthritis Index, and University of California, Los Angeles Activity Scale (P < .001). CONCLUSION This study indicates that MoM-HR is a suitable option for young individuals, as demonstrated through improved functional scores and low revision rates. The survivorship of HR in the younger than 45 age-group was similar to that of total hip arthroplasty, as well as HR in older patients. Given the proposed benefits of HR, this procedure may be viewed as a viable option in patients aged younger than 45 years.
Collapse
|
11
|
The Infection Rate of Metal-on-Metal Total Hip Replacement Is Higher When Compared to Other Bearing Surfaces as Documented by the Australian Orthopaedic Association National Joint Replacement Registry. HSS J 2018; 14:99-105. [PMID: 29399002 PMCID: PMC5786592 DOI: 10.1007/s11420-017-9581-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2016] [Accepted: 08/26/2017] [Indexed: 02/07/2023]
Abstract
BACKGROUND Despite the well-documented decline in the use of metal-on-metal (MoM) implants over the last decade, there are still controversies regarding whether all MoM implants are created equally. Complications such as elevated serum metal ion levels, aseptic lymphocyte-dominated vasculitis-associated lesion (ALVAL) and pseudotumours have all been well documented, but recent studies suggest increased risk of infection with MoM bearing surfaces. Most of these studies however have small patient numbers. QUESTIONS/PURPOSES The purpose of this study was to examine the cumulative incidence of revision for infection of MoM bearing surfaces in primary hip arthroplasty at a national and single-surgeon level. METHODS Data was collected from the Australian Orthopaedic Association National Joint Replacement Registry, which contains over 98% of all arthroplasties performed in Australia since 2001. The cumulative incidence of revision for infection was extracted at a national level and single-surgeon level. RESULTS Two hundred seventy-six thousand eight hundred seventy-eight subjects were documented in the Australian registry. The 10-year cumulative percent revision for infection of MoM bearing surfaces in primary total hip replacement (THR) was 2.5% at a national level, compared to 0.8% for other bearing surfaces. The senior author contributed 1755 subjects with 7-year follow-up and a cumulative percent revision for infection of MoM bearing surfaces in primary THR of 36.9%, compared to 2.0% for other bearing surfaces. The cumulative percent of revision of MoM bearing surfaces is higher compared to other bearing surfaces; this is especially pronounced in cumulative percent of revision for infection. CONCLUSION There was a higher cumulative percent of revision for infection in MoM bearings surfaces (in particular, large-head MoM) compared to other bearing surfaces at both the national and individual-surgeon level.
Collapse
|
12
|
Are Trends in Total Hip Arthroplasty Bearing Surface Continuing to Change? 2007-2015 Usage in a Large Database Cohort. J Arthroplasty 2017; 32:3777-3781. [PMID: 28887024 DOI: 10.1016/j.arth.2017.07.044] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Revised: 07/25/2017] [Accepted: 07/26/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Bearing surface issues related to trunnionosis or metal-on-metal (MoM) articulations have likely impacted recent trends in bearing surface choice. The purpose of this study is to evaluate trends in total hip arthroplasty (THA) bearing surface use, including 2015 data, with respect to the date of operation and patient demographics. METHODS The Humana dataset was reviewed from 2007 through 2015 to analyze bearing surface usage in primary THA. Four bearing surface types were identified by International Classification of Disease, 10th Revision codes and trended throughout the years: metal-on-polyethylene (MoP), ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), and MoM. Prevalence was analyzed as a function of age and sex. RESULTS Of the 28,504 primary THA procedures, the most commonly used bearing was MoP (46.1%), followed by CoP (33.2%), MoM (17.1%), and ceramic-on-ceramic (3.6%). The use of CoP bearings significantly increased from 6.4% in 2007 to 52.0% in 2015, while MoM bearings decreased during this period. MoP bearings decreased over 2012-2015 (P < .001). CoP usage decreased with age, while MoP bearings increased with a transition occurring at 65-69 years of age. Women were more likely to receive MoP bearings (odds ratio [OR] 1.2), while men were more likely to receive MoM and CoP bearings (OR 1.1). Multivariate logistic regression showed age to be an independent predictor of bearing surface choice with patients 65 and older more likely to receive MoP bearings (OR 3.2). CONCLUSION Bearing surface choice in primary THA has changed tremendously from 2007 to 2015. MoM bearing use has decreased as a result of adverse effects. Age continues to remain a significant factor in bearing surface choice.
Collapse
|
13
|
National Trends in Primary Total Hip Arthroplasty in Extremely Young Patients: A Focus on Bearing Surface Usage From 2009 to 2012. J Arthroplasty 2016; 31:63-8. [PMID: 27430185 DOI: 10.1016/j.arth.2016.01.061] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2015] [Revised: 01/21/2016] [Accepted: 01/25/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The ideal bearing surface for primary total hip arthroplasty (THA) in young patients remains a debate. Data on recent national trends are lacking. The purpose of this study is to provide an analysis on the national epidemiologic trends of bearing surface usage in patients aged ≤30 years undergoing THA from 2009 through 2012. METHODS Using the Healthcare Cost and Utilization Project Nationwide Inpatient Sample from 2009 to 2012, 9265 THA discharges (4210 coded by bearing surface) were identified in patients aged ≤30 years. Prevalence of surface type was analyzed along with patient and hospital demographic data. Statistical analysis was performed using SAS (SAS version 9.1; SAS, Inc, Cary, NC). Significance was set at P < .05. RESULTS Ceramic-on-polyethylene (CoP) bearing surfaces were most commonly used, representing 35.6% of cases, followed by metal-on-polyethylene (MoP; 28.0%), metal-on-metal (MoM; 19.3%), and ceramic-on-ceramic (CoC; 17.0%) bearing surfaces. Hard-on-hard bearing surfaces (MoM and CoC) represented only 36.4% of cases, a significant decrease from previously reported findings (2006-2009) where hard-on-hard bearing surfaces were the majority (62.2%; P < .05). Hard-on-hard bearing surface usage decreased from 2009 to 2012 (MoM: 29.7% to 10.2%; CoC: 20.0% to 14.7%), whereas hard-on-soft bearing surface usage (MoP and CoP) increased. CoP bearing surfaces saw the most significant increase from 25.7% in 2009 to 48.2% in 2012. A cost analysis revealed that CoP discharges were associated with higher hospital charges than other surface types, with an average charge of $66,457 (P < .05). CONCLUSION Use of hard-on-hard surfaces has decreased significantly in this population, whereas CoP and MoP surfaces have become increasingly common. Determining the optimal bearing surface for extremely young patients continues to be a challenge for orthopedic surgeons as they weigh the risks and benefits of each.
Collapse
|
14
|
The Prevalence of Positive Findings on Metal Artifact Reduction Sequence Magnetic Resonance Imaging in Metal-on-Metal Total Hip Arthroplasty. J Arthroplasty 2016; 31:1519-23. [PMID: 26876943 DOI: 10.1016/j.arth.2016.01.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Revised: 12/28/2015] [Accepted: 01/13/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND We sought to assess the prevalence of soft tissue changes seen on magnetic resonance imaging (MRI) after metal-on-metal (MOM) total hip arthroplasty (THA) and determine if the presence of pseudotumors was associated with metal ion levels, acetabular cup position, outcomes scores, and femoral head size. METHODS After receiving an institutional review board exemption for secondary data analysis, we performed a cross-sectional study identifying 55 patients (55 hips) that underwent primary THA with a MOM articulation and had subsequent MRI imaging between February 2013 and February 2014 at a single academic medical center. RESULTS Twenty-four patients (44%) had no evidence of pseudotumors, 27 (49%) had type I pseudotumors, and 4 (7%) were classified as having type II pseudotumors. The presence and severity of pseudotumors were associated with higher serum chromium levels (P = .043). Neither acetabular inclination nor acetabular version was associated with the presence of pseudotumors, the severity of pseudotumors, or elevated serum metal ion levels (all P > .05). Increased metal ion levels were associated with lower Harris Hip Score and higher Harris Hip Score pain subscores (all P < .05). CONCLUSION In conclusion, pseudotumors on metal artifact reduction sequencing MRI may be present in both symptomatic and asymptomatic MOM THAs. Surgeons should therefore exercise caution in placing too much emphasis on isolated studies such as cross-sectional imaging. Instead, a structured approach to evaluation of MOM arthroplasty should be followed.
Collapse
|
15
|
Clinical results of the conserve plus metal on metal hip resurfacing: an independent series. J Arthroplasty 2015; 30:68-73. [PMID: 25212284 DOI: 10.1016/j.arth.2014.08.005] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2014] [Revised: 08/05/2014] [Accepted: 08/07/2014] [Indexed: 02/01/2023] Open
Abstract
The purpose of the present study was to report the clinical and radiographic results of an independent series of the Conserve Plus hip resurfacing. Five hundred forty-eight consecutive hip resurfacings were performed using the Conserve Plus prosthesis in 458 patients (350 males) with a mean age of 48.3 years (range 19 to 66). No patients were lost to follow-up. At a mean follow-up of 6.6 years (3.9 to 11.9) thirty (5.4%) hips required conversion to a total hip arthroplasty (THA) (20 males, 10 females, mean age=48.3±7.3 years). Five-year survival with as revision endpoint was 94.5% (95% CI: 93.5% to 95.5%). This study confirms the good clinical results previously reported with the Conserve Plus hip resurfacing device.
Collapse
|
16
|
Accuracy of methods for calculating volumetric wear from coordinate measuring machine data of retrieved metal-on-metal hip joint implants. Proc Inst Mech Eng H 2014; 228:237-49. [PMID: 24531891 DOI: 10.1177/0954411914524188] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
This study compared the accuracy and sensitivity of several numerical methods employing spherical or plane triangles for calculating the volumetric wear of retrieved metal-on-metal hip joint implants from coordinate measuring machine measurements. Five methods, one using spherical triangles and four using plane triangles to represent the bearing and the best-fit surfaces, were assessed and compared on a perfect hemisphere model and a hemi-ellipsoid model (i.e. unworn models), computer-generated wear models and wear-tested femoral balls, with point spacings of 0.5, 1, 2 and 3 mm. The results showed that the algorithm (Method 1) employing spherical triangles to represent the bearing surface and to scale the mesh to the best-fit surfaces produced adequate accuracy for the wear volume with point spacings of 0.5, 1, 2 and 3 mm. The algorithms (Methods 2-4) using plane triangles to represent the bearing surface and to scale the mesh to the best-fit surface also produced accuracies that were comparable to that with spherical triangles. In contrast, if the bearing surface was represented with a mesh of plane triangles and the best-fit surface was taken as a smooth surface without discretization (Method 5), the algorithm produced much lower accuracy with a point spacing of 0.5 mm than Methods 1-4 with a point spacing of 3 mm.
Collapse
|
17
|
Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography. J Orthop Res 2013; 31:2032-9. [PMID: 23966288 DOI: 10.1002/jor.22461] [Citation(s) in RCA: 103] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2012] [Accepted: 07/15/2013] [Indexed: 02/04/2023]
Abstract
Widespread concern exists about adverse tissue reactions after metal-on-metal (MoM) total hip replacement (THR). Concerns have also been expressed with wear and corrosion of taper junctions in THR. We report the effect of surface finish and contact area associated with a single combination of materials of modular tapers. In an in vitro test, we investigated the head/neck (CoCrMo/Ti) interface of modular THRs using commercially available heads. Wear and corrosion of taper surfaces was compared following a 10 million loading cycle. Surface parameters and profiles were measured before and after testing. Electrochemical static and dynamic corrosion tests were performed under loaded and non-loaded conditions. After the load test, the surface roughness parameters on the head taper were significantly increased where the head/neck contact area was reduced. Similarly, the surface roughness parameters on the head taper were significantly increased where rough neck tapers were used. Corrosion testing showed breaching of the passive film on the rough but not the smooth neck tapers. Thus, surface area and surface finish are important factors in wear and corrosion at modular interfaces.
Collapse
|
18
|
Is second generation metal-on-metal primary total hip arthroplasty with a 28 mm head a worthy option?: a 12- to 18-year follow-up study. J Arthroplasty 2013; 28:1828-33. [PMID: 23890829 DOI: 10.1016/j.arth.2013.06.022] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/10/2013] [Revised: 05/28/2013] [Accepted: 06/15/2013] [Indexed: 02/01/2023] Open
Abstract
To determine whether MoM THA with a small head is still worthy of use, we investigated survivorship, complications, and factors influencing failure. Of 149 consecutive patients (195 hips), 141 (180 hips) of mean age 43 (19-55) years were available for review at a mean of 14.4 years postoperatively. Survivorship for cup revision for any cause was 97.8% at 18.4 years postoperatively. Nine hips generated complaints of groin pain; six showed periacetabular osteolysis, one had pain without radiological change, and two were diagnosed as symptomatic pseudotumors. Four of six hips with periacetabular osteolysis or aseptic loosening were revised. Surgery- and patient-related factors had no effect in results. Our results are encouraging, however, further study will be necessary to determine the incidence and fates of pseudotumors after MoM THA with a small head.
Collapse
|
19
|
Is increased modularity associated with increased fretting and corrosion damage in metal-on-metal total hip arthroplasty devices?: a retrieval study. J Arthroplasty 2013; 28:2-6. [PMID: 23910820 PMCID: PMC3971476 DOI: 10.1016/j.arth.2013.05.040] [Citation(s) in RCA: 111] [Impact Index Per Article: 10.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2012] [Revised: 05/16/2013] [Accepted: 05/30/2013] [Indexed: 02/01/2023] Open
Abstract
This retrieval study documents taper damage at modular interfaces in retrieved MOM THA systems and investigates if increased modularity is associated with increased fretting and corrosion. One hundred thirty-four (134) heads and 60 stems (41 modular necks) of 8 different bearing designs (5 manufacturers) were analyzed. Damage at the shell-liner interface of 18 modular CoCr acetabular liners and the corresponding 11 acetabular shells was also evaluated. The results of this study support the hypothesis that fretting and corrosion damage occurs at a variety of modular component interfaces in contemporary MOM THAs. We also found that modularity of the femoral stem was associated with increased damage at the head. An analysis of component and patient variables revealed that dissimilar alloy pairing, larger head sizes, increased medio-lateral offsets and longer neck moment arms were all associated with increased taper damage at the modular interfaces.
Collapse
|
20
|
Metal ions activate vascular endothelial cells and increase lymphocyte chemotaxis and binding. J Orthop Res 2013; 31:1484-91. [PMID: 23629852 PMCID: PMC3957232 DOI: 10.1002/jor.22377] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2012] [Accepted: 04/04/2013] [Indexed: 02/04/2023]
Abstract
Metal on metal articulations in hip arthroplasty offer advantages, including lower volumetric wear compared to conventional metalonpolyethylene bearings, and increased resistance to dislocation. Reports described early failures, with histologic features similar to a Type IV immune response. Mechanisms by which metal wear products cause this reaction are not completely understood. We hypothesized a mechanism through direct activation of endothelial cells (ECs) by metal ions, resulting in both vasculitis and accumulation of lymphocytes without prior immune sensitization. Effects of metal ions were evaluated using human ECs in culture. Alterations in chemotactic proteins IL8 and MCP1 were assessed, as was upregulation of the adhesion molecule ICAM-1 and lymphocyte binding to ECs. Cobalt increased secretion of IL8 and MCP1 significantly, and upregulated the expression of ICAM-1 in ECs compared to stimulation by chromium and controls. Binding of lymphocytes to ECs and transEC migration were both significantly increased by cobalt but not chromium. These findings suggest that cobalt contributes more to the activation of ECs and lymphocyte binding than chromium without an allergic response. Some of the adverse tissue reactions to implants with components made of cobalt-chromium-molybdenium alloys may be due in part to activation of the endothelium by metal ions.
Collapse
|
21
|
Effect of simplifications of bone and components inclination on the elastohydrodynamic lubrication modeling of metal-on-metal hip resurfacing prosthesis. Proc Inst Mech Eng H 2013; 227:523-34. [PMID: 23637262 DOI: 10.1177/0954411912472845] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
It is important to study the lubrication mechanism of metal-on-metal hip resurfacing prosthesis in order to understand its overall tribological performance, thereby minimize the wear particles. Previous elastohydrodynamic lubrication studies of metal-on-metal hip resurfacing prosthesis neglected the effects of the orientations of the cup and head. Simplified pelvic and femoral bone models were also adopted for the previous studies. These simplifications may lead to unrealistic predictions. For the first time, an elastohydrodynamic lubrication model was developed and solved for a full metal-on-metal hip resurfacing arthroplasty. The effects of the orientations of components and the realistic bones on the lubrication performance of metal-on-metal hip resurfacing prosthesis were investigated by comparing the full model with simplified models. It was found that the orientation of the head played a very important role in the prediction of pressure distributions and film profiles of the metal-on-metal hip resurfacing prosthesis. The inclination of the hemispherical cup up to 45° had no appreciable effect on the lubrication performance of the metal-on-metal hip resurfacing prosthesis. Moreover, the combined effect of material properties and structures of bones was negligible. Future studies should focus on higher inclination angles, smaller coverage angle and microseparation related to the occurrences of edge loading.
Collapse
|