1
|
Trunnionosis in Metal-on-Polyethylene Total Hip Arthroplasty With Periprosthetic Infection: A Case Report. Cureus 2023; 15:e49401. [PMID: 38149154 PMCID: PMC10750139 DOI: 10.7759/cureus.49401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 11/25/2023] [Indexed: 12/28/2023] Open
Abstract
A 67-year-old man who underwent right hemiarthroplasty and left total hip arthroplasty (THA) experienced left hip pain two years previously. No previous diagnosis was made at other hospitals. Radiography revealed left hip trunnionosis because of stem-neck shortening, with periprosthetic joint infection (PJI) spreading to both hips. Bilateral revision THA was performed, but the treatment was difficult due to the delayed diagnosis, necessitating the extraction of the well-fixed stem for PJI. Trunnionosis is caused by implant-related, surgical, and patient factors, and early diagnosis is important because of its association with PJI. Furthermore, even implants with few reports of trunnionosis can lead to this complication. Surgeons should always consider that performing THA using a large-diameter head predisposes the patient to trunnionosis.
Collapse
|
2
|
Ceramic-on-polyethylene hip arthroplasty reduces the risk of postoperative periprosthetic joint infection. J Orthop Res 2022; 40:2133-2138. [PMID: 34812555 DOI: 10.1002/jor.25230] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 11/02/2021] [Accepted: 11/20/2021] [Indexed: 02/04/2023]
Abstract
Metal-on-polyethylene (MoP) total hip arthroplasty (THA) prostheses are known to release metal debris. Basic science studies suggest that metal implants induce a pro-inflammatory response that ultimately chemoattracts leukocytes including macrophages and neutrophils to the surgical site. This raises concern of higher risk of infection with these prostheses through the "trojan horse" mechanism by which neutrophils and macrophages transport intracellular pathogens from a remote site. This study compared the infection occurrence between MoP and ceramic-on-polyethylene (CoP) implants to determine if a higher infection rate in MoP is present. We reviewed a consecutive series of 6052 CoP and 4550 MoP primary THA patients from 2015 to 2019. The occurrence of periprosthetic joint infection at 2 years was defined according to the 2018 ICM definition. Statistical analysis consisted of descriptive statistics, univariate analysis, and regression modeling. When compared to CoP, MoP patients were older, included more females, had a higher body mass index, and more commonly affected by comorbidities according to Elixhauser's score. Total revisions were higher in the MoP group (3.19% vs. 2.41%) The absolute incidence of PJI was higher in MoP (2.40% vs. 1.64%). When we adjusted for confounding factors, MoP was found independently associated with a higher PJI risk. Despite MoP and CoP both being widely used for primary THA, we found a higher incidence of PJI in MoP patients. The association remained significant when controlled for possible confounders. We hypothesize that leukocyte recruitment to these implants may play a role and should be further investigated.
Collapse
|
3
|
Metal Articulations as a Source of Total Hip Arthroplasty Pain. J Arthroplasty 2022; 37:1483-1487. [PMID: 35101592 DOI: 10.1016/j.arth.2022.01.063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 01/03/2022] [Accepted: 01/20/2022] [Indexed: 02/02/2023] Open
Abstract
The consensus systematic risk stratification algorithm from the American Association of Hip and Knee Surgeons, the American Academy of Orthopaedic Surgeons, and The Hip Society summarizes clinical challenges in evaluation and treatment of metal-on-polyethylene total hip arthroplasty (THA) patients with adverse local tissue reaction (ALTR) due to mechanically assisted crevice corrosion (MACC), reviews up-to-date evidence, and identifies the areas for future research in order to provide a useful resource for orthopedic surgeons providing care to these patients. A painful THA has various intrinsic and extrinsic causes. ALTR is one of the intrinsic causes in patients with painful THA. The occurrence of ALTR due to MACC at modular junctions is likely to be multifactorial, including implant, surgical, and patient factors. Therefore, a systematic evaluation needs to involve a focused clinical history, detailed physical examination, laboratory tests, and imaging in order to identify potential differential diagnoses. There should be a low threshold to perform a systematic evaluation of patients with painful non-metal-on-metal THA, including patients with metal-on-polyethylene THA, and modular dual-mobility THA with the CoCr metal acetabular insert, as early recognition and diagnosis of ALTR due to MACC will facilitate initiation of appropriate treatment prior to significant adverse biological reactions. Specialized tests such as blood metal analysis and metal artifact reduction sequence magnetic resonance imaging are important modalities in evaluation and management of ALTR in patients with painful THA.
Collapse
|
4
|
High Incidence of Mechanically Assisted Crevice Corrosion at 10 Years in Non-Cemented, Non-Recalled, Contemporary Total Hip Arthroplasties. J Arthroplasty 2022; 37:S941-S946. [PMID: 34822931 DOI: 10.1016/j.arth.2021.11.026] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 10/19/2021] [Accepted: 11/02/2021] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND One percent to 3% of contemporary non-cemented total hip arthroplasties (THAs) present with symptomatic mechanically assisted crevice corrosion (MACC). The incidence of this problem, however, as well as the rate of asymptomatic elevations in serum cobalt, is unknown. METHODS Cobalt and chromium levels were obtained in conjunction with radiographs at routine 10-year surveillance follow-up of THAs from a single manufacturer with a titanium stem, cobalt alloy femoral head, and cross-linked polyethylene countersurface. RESULTS Ten-year follow-up of patients with 162 consecutive THAs revealed that 17 patients with 18 hips had died of unrelated causes prior to metal ion testing. Two hips were revised for other reasons, and of the remaining 142 hips, 33 were in patients who were lost, leaving 109 hips (77% of those in alive patients and unrevised for other reasons and 67% of the entire cohort) for investigation. Sixty-three patients (58%) had a serum cobalt less than 1 ppb, and 35 (32%) a cobalt of ≥1 ppb, a cutoff consistent with MACC. Of the 32 hips with definite MACC, 15 of 32 (47%) patients were symptomatic, 16 of 30 (53%) patients had adverse local tissue reaction on magnetic resonance imaging, and 19 of 32 (59%) patients have undergone revision surgery for MACC to date. CONCLUSION At 10-year follow-up, a minimum of 22% (35/162) of hips had a cobalt level more than 1 ppb, consistent with MACC. Symptoms and adverse local tissue reactions are each present about one-half of the time, and 59% of those with documented MACC have undergone revision.
Collapse
|
5
|
Abstract
AIMS This study investigates head-neck taper corrosion with varying head size in a novel hip simulator instrumented to measure corrosion related electrical activity under torsional loads. METHODS In all, six 28 mm and six 36 mm titanium stem-cobalt chrome head pairs with polyethylene sockets were tested in a novel instrumented hip simulator. Samples were tested using simulated gait data with incremental increasing loads to determine corrosion onset load and electrochemical activity. Half of each head size group were then cycled with simulated gait and the other half with gait compression only. Damage was measured by area and maximum linear wear depth. RESULTS Overall, 36 mm heads had lower corrosion onset load (p = 0.009) and change in open circuit potential (OCP) during simulated gait with (p = 0.006) and without joint movement (p = 0.004). Discontinuing gait's joint movement decreased corrosion currents (p = 0.042); however, wear testing showed no significant effect of joint movement on taper damage. In addition, 36 mm heads had greater corrosion area (p = 0.050), but no significant difference was found for maximum linear wear depth (p = 0.155). CONCLUSION Larger heads are more susceptible to taper corrosion; however, not due to frictional torque as hypothesized. An alternative hypothesis of taper flexural rigidity differential is proposed. Further studies are necessary to investigate the clinical significance and underlying mechanism of this finding. Cite this article: Bone Jt Open 2021;2(11):1004-1016.
Collapse
|
6
|
Corrosion Concerns? Trends in Metal-on-Polyethylene Total Hip Arthroplasty Revision Rates and Comparisons Against Ceramic-on-Polyethylene up to 10 Years of Follow-Up. J Arthroplasty 2020; 35:2919-2925. [PMID: 32475785 DOI: 10.1016/j.arth.2020.05.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/11/2020] [Revised: 04/10/2020] [Accepted: 05/02/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND We compared the revision risk between metal-on-polyethylene (MOP) and ceramic-on-polyethylene (COP) total hip arthroplasty patients and evaluated temporal changes in short-term revision risks for MOP patients. METHODS Primary MOP (n = 9480) and COP (n = 3620) total hip arthroplasties were evaluated from the Medicare data set (October 2005 to December 2015) for revision risk, with up to 10 years of follow-up using multivariate analysis. Temporal change in the short-term revision risk for MOP was evaluated (log-rank and Wilcoxon tests). RESULTS Revision incidence was 3.8% for COP and 4.3% for MOP. MOP short-term revision risk did not change over time (P ≥ .844 at 1 year and .627 at 2 years). Dislocation was the most common reason for revision (MOP: 23.5%; COP: 24.8%). Overall adjusted revision risks were not different between MOP and COP up to 10 years of follow-up (P ≥ .181). CONCLUSIONS Concerns with corrosion for metal heads do not appear to result in significantly elevated revision risk for MOP at up to 10 years. Corrosion does not appear as a primary reason for revision compared to other mechanisms.
Collapse
|
7
|
Femoral head material loss at the head-neck junction in total hip arthroplasty: the effect of head size, stem material and stem offset. Hip Int 2019; 29:647-651. [PMID: 30499342 DOI: 10.1177/1120700018814473] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Material loss at the head-neck junction in total hip arthroplasty may cause adverse clinical symptoms and implant failure. The purpose of this study was to quantitatively examine the effects of head size, stem material and stem offset on material loss of the head-neck taper interface of a single trunnion design in retrieval implants of metal on polyethylene bearing surfaces. METHODS A retrieval study was performed to identify all 28-mm and 32-mm femoral heads from a single implant/taper design implanted for >2 years. This included n = 56 of the 28-mm heads and n = 23 of the 32-mm heads. The 28-mm femoral heads were matched to 32-mm femoral heads based on time in vivo and head length. A coordinate measuring machine was used to determine maximum linear corrosion depth (MLD). Differences in MLD for head diameter, stem material, and stem offset were determined. RESULTS There were no differences between groups for age, gender, BMI, or implantation time. There was no difference in MLD between 28 mm and 32 mm matched paired head diameters (p = 0.59). There was also no difference in MLD between titanium or cobalt-chromium stems (p = 0.79), and regular or high-offset stems (p = 0.95). CONCLUSION There is no statistical difference in femoral head MLD at the head-neck junction in THA between 28-mm and 32-mm matched paired femoral heads, similar or mixed alloy coupled femoral head stem constructs, and regular or high offset stems.
Collapse
|
8
|
A Case Report and Literature Review to Aid in the Management of Trunnion Failure in Hip Arthroplasty Patients: Can Trunnionosis and Prosthetic Joint Infection Co-Exist? Cureus 2019; 11:e5544. [PMID: 31687316 PMCID: PMC6819065 DOI: 10.7759/cureus.5544] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
Trunnionosis is a type of corrosion and wear at the head-neck taper junction of the femoral implant, and it can be a slow and silent catastrophe. Simultaneous prosthetic joint infection (PJI) is occasionally possible based on the fulfillment of a few of the minor criteria from the Musculoskeletal Infection Society (MSIS), but the existing literature lacks adequate evidence to support that the infection actually exists. We are presenting a case of an 82-year-old man with right total hip arthroplasty performed over a decade prior to presenting to the emergency room with a sudden-onset pop followed by groin pain and difficulty in walking. Radiographs showed a dissociated femoral implant at the level of trunnion with malalignment and heterotopic ossification. Metal Artifact Reduction Sequence MRI of the right hip showed mixed type-two and type-three pseudotumors, and atrophy of surrounding abductor muscles. The erythrocyte sedimentation rate was within normal limits, C-reactive protein was borderline raised, and serum cobalt-chromium levels were elevated without any signs of systemic metal toxicity. Hip joint aspirate revealed blood-stained fluid flooded with red blood cells, leukocytes and neutrophils, and a positive alpha-defensin assay. These findings were interpreted as positive for prosthetic joint infection. Intraoperatively, there was severe wear of the inferomedial aspect of the femoral head-neck junction and extensive metallosis throughout the right hip. Tissue and fluid specimens were sent for cultures, sensitivities, and histopathology for pseudotumor and infection evaluation. An articulating antibiotic spacer was then placed with the intent to perform a staged reconstruction of the femur and right acetabulum. Final synovial, bone, and soft tissue cultures, as well as histopathological photomicrograph of the tissue slides, were negative for infection. This case demonstrates the striking features of metallosis associated with trunnion failure of a metal-on-polyethylene total hip joint prosthesis that was simultaneously showing signs of prosthetic infection by satisfying the minor criteria according to the latest guidelines by the MSIS with a strikingly high cell count of red blood cells in the synovial fluid exam, indicating inflamed hyper-vascular pseudotumors vs. hemarthrosis vs. bloody tap. Diagnostic dilemma led by positive synovial fluid alpha defensin, high synovial neutrophil and white cell count results with negative final cultures or infection on histological slides raises concern that infection was not present and two-stage revision arthroplasty with six weeks of antibiotics was not necessary along with increased risk of morbidity, mortality as well as cost of care.
Collapse
|
9
|
Abstract
Particle disease from the release of metal, cement, ceramic, or polyethylene particles is a rare condition in total knee replacement. Wear, fracture, or corrosion of the components leads to foreign body reaction in the joint, followed by pain, swelling, limited motion, difficulty in walking, functional disability, and occasional systemic disease. This paper presents two cases of metal-on-cement disease as an etiology for the implant failure wherein the metal particles were shed off from the implant, along with cement and polyethylene particles, leading to a complex foreign body reaction in the failed total knee. We have coined this phenomenon as "cementallosis." Initial symptoms and signs from implant failure in both patients were mild, intermittent mediolateral knee pain that was aggravated after walking but no pain at rest or at night. The pain was associated with a 'buckling' sensation, recurrent knee swelling, and gradually worsening knee range of motion. Clinical examination in both cases was suggestive of a well-healed anterior midline surgical scar, mild to moderate effusion, mild diffuse tenderness over the entire joint, limited functional range of motion, grade 1+ laxity throughout the range of motion, and intact distal neurovascular status. Routine blood and synovial fluid workup were inconclusive for identifying the exact etiology of the patient's symptoms. Radiographs, computed tomography (CT) scans, as well as bone scans, were negative for prosthetic joint infection, component malalignment, polyethylene wear, maltracking, or loosening of the components but showed mild to moderate effusions, synovial hypertrophy, and mild scattered periprosthetic osteolysis. Intraoperatively, there was significant synovial hypertrophy with dark pigment deposition and apparent dissociation of the femoral and tibial components from the underlying cement mantle, although the cement was well-adhered to the underlying bone. Synovial fluid and multiple tissue specimens were suggestive of complex foreign body granulomas with metal, cement, and polyethylene particles. These patients had undergone surgery by the same surgery team in the community using the same implant. These cases demonstrate the failure of a total knee arthroplasty implant at the metal-cement interface with features of adverse local tissue reactions that resemble a pseudotumor from the metal-on-metal disease in the knee joint. We have compared and contrasted the clinical presentations, laboratory, imaging, histopathological, and intraoperative study findings in these cases. Knowing what to look for will aid in early diagnosis, ordering necessary investigations, better surgery planning, reducing operative time, as well as improving outcomes and cost of care. The aim of this paper is to educate the audience about this new phenomenon as a cause of knee prosthesis failure produced by a complex pseudotumor-like foreign body reaction that involves metal, cement, and polyethylene particles.
Collapse
|
10
|
Hip and Knee Section, Prevention, Prosthesis Factors: Proceedings of International Consensus on Orthopedic Infections. J Arthroplasty 2019; 34:S309-S320. [PMID: 30348551 DOI: 10.1016/j.arth.2018.09.016] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023] Open
|
11
|
Surface integrity of polyethylene liners following trunnionosis of a dual modular neck total hip implant. Hip Int 2018; 28:629-635. [PMID: 29756511 DOI: 10.1177/1120700018754336] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
BACKGROUND There has been a trend in the evolution of total hip arthroplasty towards increased modularity; with this increase in modularity come some potentially harmful consequences. Modularity at the neck shaft junction has been linked to corrosion, adverse reaction to metal debris and pseudotumour formation. AIM The aim of this retrieval study is to assess whether the surface integrity of the polyethylene (PE) liner is affected by metal wear debris in a single implant design series of THA revised for trunnionosis. METHODS A retrieval analysis of thirty dual-taper modular neck hip prostheses was performed; the mean time from implantation to revision was 2.7 years (1.02-6.2). PE liners were analysed using a scanning electron microscope with an energy dispersive spectrometer to assess for metal particles embedded on the liner surface. Serum metal ion levels and inflammatory markers were also analysed. RESULTS There were small numbers of metal particles present on the PE liners. The mean number of metal particles per liner was four and the particles varied in size from 0.5 µm to 122 µm mean 16 µm. All patients had elevated metal ion levels: cobalt 6.02 µg/l, chromium 1.22 µg/l, titanium 3.11 µg/l. The cobalt:chromium ratio was 7.55:1. Inflammatory markers were also marginally raised (ESR 17; CRP 10). CONCLUSION These results suggest that retention of PE liners may be reasonable when performing isolated revision of the femoral component in cases of failure at the modular neck stem junction, especially when the inner diameter of the liner is already optimised for head size and stability.
Collapse
|
12
|
Evidence-Based Management of Trunnionosis in Metal-on-Polyethylene Total Hip Arthroplasty: A Systematic Review. J Arthroplasty 2018; 33:3343-3353. [PMID: 29929829 DOI: 10.1016/j.arth.2018.05.035] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Revised: 05/21/2018] [Accepted: 05/23/2018] [Indexed: 02/01/2023] Open
Abstract
Multiple recent reports have indicated a rising awareness of trunnionosis-related implant failures, accounting for up to 3% of all total hip arthroplasty revisions. Moreover, aseptic loosening and osteolysis from local release of metal debris can be the presenting manifestations, and thus the true incidence of trunnionosis is thought to be underreported. Furthermore, the relatively unclear and multifactorial pathogenesis and the widely variable clinical presentations pose a diagnostic challenge. A consensus regarding the ideal intervention and its timing is also lacking. Because of the relative paucity of reports regarding the diagnosis and management of trunnionosis, we conducted this evidence-based review to evaluate the (1) incidence, (2) pathogenesis, (3) diagnosis, and (4) treatment of trunnionosis in metal-on-polyethylene total hip arthroplasty. We then propose an algorithm for the diagnostic work-up and management of this condition.
Collapse
|
13
|
Comparison of Postoperative Complications Following Metal-on-Metal Total Hip Arthroplasty With Other Hip Bearings in Medicare Population. J Arthroplasty 2018; 33:1826-1832. [PMID: 29510952 DOI: 10.1016/j.arth.2018.01.066] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2016] [Revised: 01/18/2018] [Accepted: 01/25/2018] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND The use of metal-on-metal (MoM) hip bearings has declined in the recent years due to strong evidence of their high complication rates and early failure. Hip implants with highly cross-linked polyethylene liners and ceramic bearings have become the modern implants of choice. We sought to determine if MoM implants are associated with higher complication and revision rates when compared to other hip bearings in the Medicare population. METHODS We retrospectively reviewed a Medicare database (2005-2011) for patients who underwent a primary total hip arthroplasty with a MoM, metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), or ceramic-on-ceramic (CoC) implant (minimum 2 years of follow-up). Patient comorbidities and medical/surgical complication rates were analyzed at various time points postoperatively. RESULTS We identified 288,118 patients, including 81,520 patients with a MoM implant, 162,881 with MoP, 33,819 with CoP, and 9898 with CoC implant. Surgical complication rates were higher for MoM implants including infection, osteolysis/polywear, mechanical complications, and need for hip irrigation and debridement. Overall revision rates were significantly higher for MoM implants (5.28%) compared to MoP (4.28%, odds ratio [OR] 1.26, P < .001) and CoP (3.52%, OR 1.55, P < .001) but only by one to two percent. MoM revision rates were similar to CoC implants (4.94%, OR 1.00, P = .096). CONCLUSIONS MoM implants were associated with higher revision rates (5.28%) compared to MoP (4.28%) and CoP (3.52%) implants in the Medicare population. Both complication and revision rates were comparable to CoC implants.
Collapse
|
14
|
Effect of Bearing Type on Taper Material Loss in Hips From 1 Manufacturer. J Arthroplasty 2018; 33:1588-1593. [PMID: 29370957 DOI: 10.1016/j.arth.2017.12.022] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/24/2017] [Revised: 12/05/2017] [Accepted: 12/19/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Numerous studies have reported on clinical significant volumes of material loss and corrosion at the head-stem junction of metal-on-metal (MOM) hips; less is understood about metal-on-polyethylene (MOP) hips. We compared the effect of bearing type (MOM vs MOP) on taper material loss for a hip system of a single design. METHODS In this cohort study, we recruited retrieved MOM (n = 30) and MOP (n = 22) bearing hips that were consecutively received at our center. We prospectively collected associated clinical and imaging data. We measured the severity of corrosion and volumes of material loss at each head taper surface and used multivariate statistical analysis to investigate differences between the 2 bearing types. RESULTS The median rate of material loss for the MOM and MOP groups was 0.81 mm3/y (0.01-3.45) and 0.03 mm3/y (0-1.07), respectively (P < .001). Twenty-nine of 30 MOM hips were revised for adverse metal reactions, compared with 1 of 22 MOP hips. CONCLUSION MOP hips lost significantly less material from their taper junctions than MOM hips. Our results can reassure patients with MOP Pinnacle hips that they are unlikely to experience clinically significant problems related to material loss from the taper junction.
Collapse
|
15
|
Trunnionosis: Does Head Size Affect Fretting and Corrosion in Total Hip Arthroplasty? J Arthroplasty 2016; 31:2332-6. [PMID: 27067470 DOI: 10.1016/j.arth.2016.03.009] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2015] [Revised: 03/02/2016] [Accepted: 03/04/2016] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Wear and tribocorrosion at the modular head-neck taper interface may be a cause of failure in metal-on-polyethylene total hip arthroplasty (THA). The present investigation endeavored to elucidate the effect of femoral head diameter on fretting and corrosion in retrieved head-neck tapers. METHODS A retrieval analysis of THA prostheses in vivo for a minimum of 1 year was performed. Twenty-three femoral heads of 32-mm diameter were matched with 28-mm heads based on time in vivo and head length (-3 mm to +8 mm). All included implants featured a single taper design from a single manufacturer. Fretting and corrosion damage scoring was performed for each implant under stereomicroscopic visualization. RESULTS Head diameter was observed to affect fretting (P = .01), with 32-mm femoral heads exhibiting greater total fretting scores than 28-mm heads. Fretting damage was greatest (P = .01) in the central concentric zone of the femoral head bore tapers, regardless of head diameter, length, or stem offset. No significant effect on total corrosion scores was observed for any head or stem variable. Retrieved implant total corrosion scores were positively correlated (ρ = 0.51, P < .001) with implantation time. CONCLUSION Increased femoral head diameter in THA may produce greater fretting damage owing to and increased head-neck moment arm. There is no associated increase in corrosion with 28-mm and 32-mm heads of this taper design. The longer a THA prosthesis is implanted, the greater the risk of damage due to corrosion.
Collapse
|
16
|
Increased expression of inducible co-stimulator on CD4+ T-cells in the peripheral blood and synovial fluid of patients with failed hip arthroplasties. Bone Joint Res 2016; 5:52-60. [PMID: 26868893 PMCID: PMC4852791 DOI: 10.1302/2046-3758.52.2000574] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2015] [Accepted: 12/09/2015] [Indexed: 12/12/2022] Open
Abstract
OBJECTIVES T-cells are considered to play an important role in the inflammatory response causing arthroplasty failure. The study objectives were to investigate the composition and distribution of CD4+ T-cell phenotypes in the peripheral blood (PB) and synovial fluid (SF) of patients undergoing revision surgery for failed metal-on-metal (MoM) and metal-on-polyethylene (MoP) hip arthroplasties, and in patients awaiting total hip arthroplasty. METHODS In this prospective case-control study, PB and SF were obtained from 22 patients (23 hips) undergoing revision of MoM (n = 14) and MoP (n = 9) hip arthroplasties, with eight controls provided from primary hip osteoarthritis cases awaiting arthroplasty. Lymphocyte subtypes in samples were analysed using flow cytometry. RESULTS The percentages of CD4+ T-cell subtypes in PB were not different between groups. The CD4+ T-cells in the SF of MoM hips showed a completely different distribution of phenotypes compared with that found in the PB in the same patients, including significantly decreased CD4+ T-central memory cells (p < 0.05) and increased T-effector memory cells (p < 0.0001) in the SF. Inducible co-stimulator (ICOS) was the only co-stimulatory molecule with different expression on CD4+ CD28+ cells between groups. In PB, ICOS expression was increased in MoM (p < 0.001) and MoP (p < 0.05) cases compared with the controls. In SF, ICOS expression was increased in MoM hips compared with MoP hips (p < 0.05). CONCLUSIONS Increased expression of ICOS on CD4+ T-cells in PB and SF of patients with failed arthroplasties suggests that these cells are activated and involved in generating immune responses. Variations in ICOS expression between MoM and MoP hips may indicate different modes of arthroplasty failure.Cite this article: Professor P. A. Revell. Increased expression of inducible co-stimulator on CD4+ T-cells in the peripheral blood and synovial fluid of patients with failed hip arthroplasties. Bone Joint Res 2016;5:52-60. doi: 10.1302/2046-3758.52.2000574.
Collapse
|
17
|
Effect of Taper Design on Trunnionosis in Metal on Polyethylene Total Hip Arthroplasty. J Arthroplasty 2015; 30:1269-72. [PMID: 25773576 DOI: 10.1016/j.arth.2015.02.031] [Citation(s) in RCA: 83] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2014] [Revised: 02/07/2015] [Accepted: 02/21/2015] [Indexed: 02/01/2023] Open
Abstract
This study examines how taper design affects corrosion and fretting at the head trunnion surface. All hip prostheses retrieved between 1999 and 2013 with 28mm/+0 heads were selected, resulting in 44 cobalt-chrome-on-polyethylene implants, representing six taper designs. Mean implantation time: 8.9±3.7years. The femoral head tapers were scored for fretting and corrosion using the Goldberg scale as both a combined score and by three zones (apex, central and base). There was no difference in age (P=0.34), BMI (P=0.29), or implantation time (P=0.19) between taper groups. The 11/13 taper had the highest combined corrosion and fretting score, but no difference (P=0.22) between groups for combined scores (P=0.22 for corrosion, P=0.19 for fretting). In a zone-specific analysis, the 11/13 taper had highest corrosion score at base zone (P=0.02). Taper design had a significant effect on corrosion at base of trunnion.
Collapse
|
18
|
Experimental validation of finite element modelling of a modular metal-on-polyethylene total hip replacement. Proc Inst Mech Eng H 2014; 228:682-92. [PMID: 24963036 DOI: 10.1177/0954411914541830] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Finite element models are becoming increasingly useful tools to conduct parametric analysis, design optimisation and pre-clinical testing for hip joint replacements. However, the verification of the finite element model is critically important. The purposes of this study were to develop a three-dimensional anatomic finite element model for a modular metal-on-polyethylene total hip replacement for predicting its contact mechanics and to conduct experimental validation for a simple finite element model which was simplified from the anatomic finite element model. An anatomic modular metal-on-polyethylene total hip replacement model (anatomic model) was first developed and then simplified with reasonable accuracy to a simple modular total hip replacement model (simplified model) for validation. The contact areas on the articulating surface of three polyethylene liners of modular metal-on-polyethylene total hip replacement bearings with different clearances were measured experimentally in the Leeds ProSim hip joint simulator under a series of loading conditions and different cup inclination angles. The contact areas predicted from the simplified model were then compared with that measured experimentally under the same conditions. The results showed that the simplification made for the anatomic model did not change the predictions of contact mechanics of the modular metal-on-polyethylene total hip replacement substantially (less than 12% for contact stresses and contact areas). Good agreements of contact areas between the finite element predictions from the simplified model and experimental measurements were obtained, with maximum difference of 14% across all conditions considered. This indicated that the simplification and assumptions made in the anatomic model were reasonable and the finite element predictions from the simplified model were valid.
Collapse
|
19
|
Changes in early serum metal ion levels and impact on liver, kidney, and immune markers following metal-on-metal total hip arthroplasty. J Arthroplasty 2014; 29:612-6. [PMID: 23993737 DOI: 10.1016/j.arth.2013.07.031] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/07/2013] [Revised: 07/22/2013] [Accepted: 07/24/2013] [Indexed: 02/01/2023] Open
Abstract
We retrospectively studied 32 consecutive patients (32 hips) who underwent THA with a Durom large-head, MOM articulation between January 2008 and December 2010. Of the patients who underwent THA using a Trilogy metal on polyethylene prosthesis during the same period, 32 were chosen to form the Trilogy group. 32 volunteers were chosen to form the control group. At the last follow-up, serum metal ion levels, liver and kidney function and host immunologic immune responses were evaluated. The mean Co and Cr levels in the Durom group were 4.33- and 1.95-fold higher than those in the Trilogy group. CD3+, CD4+ and CD8+ cell levels in the Durom group were significantly decreased. The INF-γ level in the Durom group was significantly higher than that in the Trilogy and control groups.
Collapse
|