26
|
Saeed R, Glamuzina B, Tuyet Nga MT, Zhao F, Zhang X. Supervised learning-based artificial senses for non-destructive fish quality classification. Biosens Bioelectron 2024; 267:116770. [PMID: 39288709 DOI: 10.1016/j.bios.2024.116770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2024] [Revised: 08/14/2024] [Accepted: 09/09/2024] [Indexed: 09/19/2024]
Abstract
Human sensory techniques are inadequate for automating fish quality monitoring and maintaining controlled storage conditions throughout the supply chain. The dynamic monitoring of a single quality index cannot anticipate explicit freshness losses, which remarkably drops consumer acceptability. For the first time, a complete artificial sensory system is designed for the early detection of fish quality prediction. At non-isothermal storages, the rainbow trout quality is monitored by the gas sensors, texturometer, pH meter, camera, and TVB-N analysis. After data preprocessing, correlation analysis identifies the key parameters such as trimethylamine, ammonia, carbon dioxide, hardness, and adhesiveness to input into a back-propagation neural network. Using gas and textural key parameters, around 99 % prediction accuracy is achieved, precisely classifying fresh and spoiled classes. The regression analysis identifies a few gaps due to fewer datasets for model training, which can be reduced using few-shot learning techniques in the future. However, the multiparametric fusion of texture with gases enables early freshness loss detection and shows the capacity to automate the food supply chain completely.
Collapse
|
27
|
Ahn JS, Jang CH. Real-time detection of Tau-381 protein using liquid crystal-based sensors for Alzheimer's disease diagnosis. Colloids Surf B Biointerfaces 2024; 245:114211. [PMID: 39260276 DOI: 10.1016/j.colsurfb.2024.114211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Revised: 07/02/2024] [Accepted: 09/05/2024] [Indexed: 09/13/2024]
Abstract
Tau is a protein found in the central nervous system (CNS) and is involved in stabilizing microtubules in axons. Given the link between Tau levels in the body and Alzheimer's disease (AD), there is a demand for straightforward and precise strategies to detect Tau in body fluids. In this study, we report liquid crystal (LC)-based sensors for the real-time detection of Tau protein, a well-known AD biomarker. The sensor uses a detection method based on the orientation change of the LC because of the competitive biomolecular interaction between Tau and Tau aptamers with the cationic polymer poly-L-lysine (PLL). Tau and its aptamers form stable complexes through electrostatic interactions. Owing to the consumption of the aptamer, the positively charged PLL fails to interact with the aptamer but binds to the negatively charged 1.2-dioleoyl-sn-glycero-3-phospho-(1'-rac-glycerol) sodium salt (DOPG). The PLL and DOPG complex alters the orientation of the LC to ensure a planar anchoring of the 4-cyano-4'-pentylbiphenyl (5CB)/aqueous interface; this anchoring intensifies with increasing Tau concentration, thus enabling the observation of a bright optical image. Our LC-based sensor demonstrated a low detection limit of 2.77 pg/mL in phosphate buffered saline (PBS) and 10.86 pg/mL and 19.31 pg/mL in human serum and plasma, respectively. Moreover, it is anticipated to be suitable for point-of-care diagnosis of AD because it does not require specialized analytical equipment and only requires microliters of sample.
Collapse
|
28
|
Liu J, Li N, Ye L, Zhou L, Chen G, Tang J, Zhang H, Yang H. Triple modal apta sensor arrays driven by CHA-mediated DNAzyme for signal-amplified atrazine pesticide accumulation monitoring in agricultural crops. JOURNAL OF HAZARDOUS MATERIALS 2024; 476:135172. [PMID: 38996685 DOI: 10.1016/j.jhazmat.2024.135172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Revised: 07/01/2024] [Accepted: 07/09/2024] [Indexed: 07/14/2024]
Abstract
Developing sensors with high selectivity and sensitivity is of great significance for pesticide analysis in environmental assessment. Herein, a versatile three-way sensor array was designed for the detection of the pesticide atrazine, based on the integration of catalytic hairpin assembly (CHA) amplification and three-mode signal transducers. With atrazine, CHA was triggered to generate abundant G-quadruplex. The produced G-quadruplex hybrid could assemble with thioflavin T (TFT) or hemin to mimic enzyme and induce the fluorescence enhancement by TFT, or the colorimetric increase by the oxidized chromogenic substrate and the naked-eye color change by inhibiting the L-cysteine-mediated aggregation of gold nanoparticles. A distinctive three-mode array was successfully constructed with convenience, on-site accessibility and high sensitivity for enzyme-free practical analysis of atrazine. It is also effective and reliable for analyzing real samples including paddy water, paddy soil and polished rice. The detection limits for atrazine were as low as 7.4 pg/mL by colorimetric observation and 0.25 pg/mL by fluorescent detection. Furthermore, the array was exploited to monitor the residue, distribution and bioaccumulation of atrazine in maize and rice for food security and environmental assessment. Hence, this work presented a versatile example for sensitive and on-site all-in-one pesticide analysis arrays with multiple signal report modes.
Collapse
|
29
|
Li Y, Pu X, Ding Y, Yi L, Yang Y, Gu Y, Wang S. An antifouling electrochemical sensor based on a U-shaped four-in-one peptide and poly(3,4-ethylenedioxythiophene) for vancomycin detection in fresh goat milk. Food Chem 2024; 463:141056. [PMID: 39241413 DOI: 10.1016/j.foodchem.2024.141056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Revised: 08/26/2024] [Accepted: 08/28/2024] [Indexed: 09/09/2024]
Abstract
Nonspecific adsorption of biomolecules (notably, proteins) and bacteria from unsterilized food may occur on sensor surfaces, which is still a challenge for food safety sensing. To achieve sensitive detection of unsterilized raw-food materials, in this study, a U-shaped four-in-one peptide with the sequence Ac-FLKLLKKLL-DOPA3-PPPPEEKDQDKEKaa that exhibited anchoring, antifouling, antibacterial, and recognition properties was designed. The peptide-modified sensor surface effectively prevented bacterial adhesion and proliferation while resisting biomolecule adsorption (signal inhibition rate as low as 0.51 % in single-protein solutions). A highly conductive polymer layer of poly(3,4-ethylenedioxythiophene) was introduced to improve the electrochemical performance before U-shaped four-in-one peptide anchoring. The proposed sensor could accurately detect vancomycin, with a wide linear range and limit of detection of 0.05-10 μg mL-1 and 2.06 ng mL-1 (S/N = 3), respectively. Satisfactory recovery rates (101.3-105.3 %) were achieved using diluted fresh goat milk.
Collapse
|
30
|
Tripathi G, Guha L, Kumar H. Seeing the unseen: The role of bioimaging techniques for the diagnostic interventions in intervertebral disc degeneration. Bone Rep 2024; 22:101784. [PMID: 39040156 PMCID: PMC11261287 DOI: 10.1016/j.bonr.2024.101784] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/18/2024] [Revised: 06/19/2024] [Accepted: 06/24/2024] [Indexed: 07/24/2024] Open
Abstract
Intervertebral Disc Degeneration is a pathophysiological condition that primarily affects the spinal discs, causing back pain and neurological deficits. It is caused by the contribution of several factors such as genetic predisposition, age-related degeneration, and lifestyle choices like obesity and physical activity. Even though there are medications to treat pain, there is a lack of medicines for a complete cure. The main difficulty lies in poor diagnosis of the morphological and functional changes in the disc. With the ever-increasing research on bioimaging techniques, new techniques are being developed and repurposed to evaluate disc shape and composition, and their defects like thinning or deformities on the disc, leading to the proper diagnostic intervention in intervertebral disc degeneration. In this review, we aim to present a comprehensive overview of the imaging techniques used in the pre-clinical and clinical stages for the diagnosis of intervertebral disc degeneration. First, we will discuss about patho-anatomy and the pathophysiology of degenerative disc disease with the significance and a brief description of various dyes and tracers utilized for bioimaging. Then we will shed light on the latest advancements in diagnostic modalities in intervertebral disc degeneration; concluded by an analysis of the repercussions of the methodologies and experimental systems employed in identifying mechanisms and developing therapeutic strategies in intervertebral disc degeneration.
Collapse
|
31
|
Jung J, Park J, Choe JK, Choi Y. Perfluoroalkyl functionalized-Au nanoparticle sensor: Employing rate of spectrum shifting for highly selective and sensitive detection of per- and polyfluoroalkyl substances (PFASs) in aqueous environments. WATER RESEARCH X 2024; 24:100239. [PMID: 39193396 PMCID: PMC11347827 DOI: 10.1016/j.wroa.2024.100239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2024] [Revised: 07/15/2024] [Accepted: 07/17/2024] [Indexed: 08/29/2024]
Abstract
Per- and polyfluoroalkyl substances (PFASs) are emerging contaminants detected ubiquitously and have negative impacts on human health and ecosystem; thus, developing in-situ sensing technique is important to ensure safety. Herein, we report a novel colorimetric-based sensor with perfluoroalkyl receptor attached to citrate coated gold nanoparticles (Citrate-Au NPs) that can detect several PFASs including perfluorocarboxylates with different chain lengths (PFHxA, PFOA, PFNA, PFDA), perfluorooctanoic sulfonate (PFOS), and perfluorooctanoic phosphonate (PFOPA). The sensor detects PFASs utilizing fluorous interaction between PFASs and the perfluoroalkyl receptor of Citrate-Au NPs in a solution at a fixed salt concentration, inducing changes in nanoparticle dispersity and the solution color. The rate of spectrum shift was linearly dependent on PFASs concentrations. Citrate-Au NPs with size between 29 - 109 nm were synthesized by adjusting citrate/Au molar ratios, and 78 nm showed the best sensitivity to PFOA concentration (with level of detection of 4.96 µM). Citrate-Au NPs only interacted with PFASs with perfluoroalkyl length > 4 and not with non-fluorinated alkyl compound (nonanoic acid). The performance of Citrate-Au NP based sensor was strongly dependent on the chain length of the perfluoroalkyl group and the head functional group; higher sensitivity was observed with longer chain over shorter chain, and with sulfonate functional group over carboxylate and phosphonate. The sensor was tested using real water samples (i.e., tap water, filtered river water), and it was found that the sensor is capable of detecting PFASs in these conditions if calibrated with the corresponding water matrix. While further optimization is needed, this study demonstrated new capability of Citrate-Au NPs based sensor for detection of PFASs in water.
Collapse
|
32
|
Dankovich LJ, Joyner JS, He W, Sesay A, Vaughn-Cooke M. CogWatch: An open-source platform to monitor physiological indicators for cognitive workload and stress. HARDWAREX 2024; 19:e00538. [PMID: 38962730 PMCID: PMC11220525 DOI: 10.1016/j.ohx.2024.e00538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Revised: 04/28/2024] [Accepted: 05/14/2024] [Indexed: 07/05/2024]
Abstract
Cognitive workload is a measure of the mental resources a user is dedicating to a given task. Low cognitive workload produces boredom and decreased vigilance, which can lead to an increase in response time. Under high cognitive workload the information processing burden of the user increases significantly, thereby compromising the ability to effectively monitor their environment for unexpected stimuli or respond to emergencies. In cognitive workload and stress monitoring research, sensors are used to measure applicable physiological indicators to infer the state of user. For example, electrocardiography or photoplethysmography are often used to track both the rate at which the heart beats and variability between the individual heart beats. Photoplethysmography and chest straps are also used in studies to track fluctuations in breathing rate. The Galvanic Skin Response is a change in sweat rate (especially on the palms and wrists) and is typically measured by tracking how the resistance of two probes at a fixed distance on the subject's skin changes over time. Finally, fluctuations in Skin Temperature are typically tracked with thermocouples or infrared light (IR) measuring systems in these experiments. While consumer options such a smartwatches for health tracking often have the integrated ability to perform photoplethysmography, they typically perform significant processing on the data which is not transparent to the user and often have a granularity of data that is far too low to be useful for research purposes. It is possible to purchase sensor boards that can be added to Arduino systems, however, these systems generally are very large and obtrusive. Additionally, at the high end of the spectrum there are medical tools used to track these physiological signals, but they are often very expensive and require specific software to be licensed for communication. In this paper, an open-source solution to create a physiological tracker with a wristwatch form factor is presented and validated, using conventional off-the-shelf components. The proposed tool is intended to be applied as a cost-effective solution for research and educational settings.
Collapse
|
33
|
Cao Y, Song Y, Fan X, Ma L, Feng T, Zeng J, Xue C, Xu J. A smartphone-assisted sensing hydrogels based on UCNPs@SiO 2-phenol red nanoprobes for detecting the pH of aquatic products. Food Chem 2024; 451:139428. [PMID: 38678665 DOI: 10.1016/j.foodchem.2024.139428] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2024] [Revised: 04/11/2024] [Accepted: 04/18/2024] [Indexed: 05/01/2024]
Abstract
For some aquatic products, pH has been considered a useful index to reflect the changes in materials during the loss of freshness. Based on the inner filter effect (IFE) between deprotonated phenol red (PR) and upconversion nanoparticles (UCNPs), UCNPs coated with PR-doped SiO2 shell were embedded in agarose hydrogel to develop a smartphone-assisted method for pH sensing. With the enhancement of pH response using a phase transfer agent (i.e., tetra butyl ammonium hydroxide, TBAH), the proposed senor realized the colorimetric and fluorescence detection of pH in the range of pH 6.6-8 and pH 6-8, respectively. The sensor also showed satisfied reversibility when switched between pH 6 and 8 for at least 5 cycles. Moreover, this sensor displayed great sensitivity, stability, and portability in analyzing actual fish, shrimp, and shellfish samples, providing a new sight for evaluating the freshness of aquatic products.
Collapse
|
34
|
Zhang S, Song G, Yang Z, Kang K, Liu X. A label-free fluorescence aptamer sensor for point-of-care serotonin detection. Talanta 2024; 277:126363. [PMID: 38850806 DOI: 10.1016/j.talanta.2024.126363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 05/06/2024] [Accepted: 06/03/2024] [Indexed: 06/10/2024]
Abstract
Serotonin, a pivotal neurotransmitter regulating various physiological functions, plays a crucial role in disease diagnosis, necessitating precise monitoring of its levels in biological fluids for accurate assessment. Aptamers, known for their high specificity and affinity, have emerged as innovative molecular probes for serotonin analysis. However, existing serotonin aptamer sensing platforms exhibit limitations in terms of portability and rapid detection capabilities. In this study, we introduce a novel, portable, label-free serotonin aptamer sensor utilizing a dye replacement strategy, achieving a short sample-to-result turnaround time and convenient signal readout through a smartphone. The performance of this aptamer sensor was thoroughly assessed across diverse physiological media, demonstrating robust stability in buffer, urine, and serum. Importantly, the detection limit was in the nanomolar range, emphasizing its suitability for the rapid, sensitive, and user-friendly detection of serotonin. This research pioneers an approach for the development of a point-of-care testing (POCT) system for serotonin with practical implications, particularly in resource-limited settings.
Collapse
|
35
|
Liu J, Zhang X, Zhang Y, Zhao B, Liu Z, Dong X, Feng S, Du Y. Mn-based Prussian blue analogues: Multifunctional nanozymes for hydrogen peroxide detection and photothermal therapy of tumors. Talanta 2024; 277:126320. [PMID: 38824861 DOI: 10.1016/j.talanta.2024.126320] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 04/18/2024] [Accepted: 05/23/2024] [Indexed: 06/04/2024]
Abstract
Nanozymes have the advantages of simple synthesis, high stability, low cost and easy recycling, and can be applied in many fields including molecular detection, disease diagnosis and cancer therapy. However, most of the current nanozymes suffer from the defects of low catalytic activity and single function, which limits their sensing sensitivity and multifunctional applications. The development of highly active and multifunctional nanozymes is an important way to realize multidisciplinary applications. In this work, Mn-based Prussian blue analogues (Mn-PBA) and their derived double-shelled nanoboxes (DSNBs) are synthesized by co-precipitation method. The nanobox structure of DSNBs formed by etching Mn-PBA with tannic acid endows Mn-PBA DSNBs with better peroxidase-like activity than Mn-PBA. A colorimetric method for the rapid and sensitive determination of H2O2 is developed using Mn-PBA DSNBs-1.5 as a sensor with a detection limit as low as 0.62 μM. Moreover, Mn-PBA DSNBs-2 has excellent photothermal conversion ability, which can be applied to the photothermal therapy of tumors to inhibit the proliferation of tumor cells without damaging other tissues and organs. This study provides a new idea for the rational design of nanozymes and the expansion of their multi-functional applications in various fields.
Collapse
|
36
|
Imran MAA, Nasirzadeh F, Karmakar C. Designing a practical fatigue detection system: A review on recent developments and challenges. JOURNAL OF SAFETY RESEARCH 2024; 90:100-114. [PMID: 39251269 DOI: 10.1016/j.jsr.2024.05.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 02/11/2024] [Accepted: 05/29/2024] [Indexed: 09/11/2024]
Abstract
INTRODUCTION Fatigue is considered to have a life-threatening effect on human health and it has been an active field of research in different sectors. Deploying wearable physiological sensors helps to detect the level of fatigue objectively without any concern of bias in subjective assessment and interfering with work. METHODS This paper provides an in-depth review of fatigue detection approaches using physiological signals to pinpoint their main achievements, identify research gaps, and recommend avenues for future research. The review results are presented under three headings, including: signal modality, experimental environments, and fatigue detection models. Fatigue detection studies are first divided based on signal modality into uni-modal and multi-modal approaches. Then, the experimental environments utilized for fatigue data collection are critically analyzed. At the end, the machine learning models used for the classification of fatigue state are reviewed. PRACTICAL APPLICATIONS The directions for future research are provided based on critical analysis of past studies. Finally, the challenges of objective fatigue detection in the real-world scenario are discussed.
Collapse
|
37
|
Luo Y, Sun Y, Wei X, He Y, Wang H, Cui Z, Ma J, Liu X, Shu R, Lin H, Xu D. Detection methods for antibiotics in wastewater: a review. Bioprocess Biosyst Eng 2024; 47:1433-1451. [PMID: 38907838 DOI: 10.1007/s00449-024-03033-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2023] [Accepted: 05/09/2024] [Indexed: 06/24/2024]
Abstract
Antibiotics are widely used as fungicides because of their antibacterial and bactericidal effects. However, it is necessary to control their dosage. If the amount of antbiotics is too much, it cannot be completely metabolized and absorbed, will pollute the environment, and have a great impact on human health. Many antibiotics usually left in factory or aquaculture wastewater pollute the environment, so it is vital to detect the content of antibiotics in wastewater. This article summarizes several common methods of antibiotic detection and pretreatment steps. The detection methods of antibiotics in wastewater mainly include immunoassay, instrumental analysis method, and sensor. Studies have shown that immunoassay can detect deficient concentrations of antibiotics, but it is affected by external factors leading to errors. The detection speed of the instrumental analysis method is fast, but the repeatability is poor, the price is high, and the operation is complicated. The sensor is a method that is currently increasingly studied, including electrochemical sensors, optical sensors, biosensors, photoelectrochemical sensors, and surface plasmon resonance sensors. It has the advantages of fast detection speed, high accuracy, and strong sensitivity. However, the reproducibility and stability of the sensor are poor. At present, there is no method that can comprehensively integrate the advantages. This paper aims to review the enrichment and detection methods of antibiotics in wastewater from 2020 to the present. It also aims to provide some ideas for future research directions in this field.
Collapse
|
38
|
Chen R, Li S, Ren S, Han D, Qin K, Jia X, Zhou H, Gao Z. Micro-/nanostructures for surface-enhanced Raman spectroscopy: Recent advances and perspectives. Adv Colloid Interface Sci 2024; 331:103235. [PMID: 38908042 DOI: 10.1016/j.cis.2024.103235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Revised: 04/04/2024] [Accepted: 06/11/2024] [Indexed: 06/24/2024]
Abstract
Surface-enhanced Raman spectroscopy (SERS) has great potential for the analysis of molecules adsorbed on metals with rough surfaces or substrates with micro-/nanostructures. Plasmonic coupling between metal nanoparticles and the morphology of the rough metal surface can produce "hot spots" that enhance Raman scattering by adsorbed molecules, typically at micro- to nanomolar concentrations, although high enhancement factors can also facilitate single-molecule detection. This phenomenon is widely applicable for chemical analysis and sensing in various fields. In this review, the latest research progress on SERS micro-/nanosensors is evaluated, and the sensors are classified according to their individual functions. Furthermore, the design principles and working mechanisms of reported SERS-active micro-/nanostructured substrates are analyzed, and the design features adopted to overcome the difficulties associated with precision detection are explored. Finally, challenges and directions for future development in this field are discussed. This review serves as a design guide for novel SERS-active substrates.
Collapse
|
39
|
Granero-Moya I, Venturini V, Belthier G, Groenen B, Molina-Jordán M, González-Martín M, Trepat X, van Rheenen J, Andreu I, Roca-Cusachs P. Nucleocytoplasmic transport senses mechanical forces independently of cell density in cell monolayers. J Cell Sci 2024; 137:jcs262363. [PMID: 39120491 DOI: 10.1242/jcs.262363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2024] [Accepted: 07/24/2024] [Indexed: 08/10/2024] Open
Abstract
Cells sense and respond to mechanical forces through mechanotransduction, which regulates processes in health and disease. In single adhesive cells, mechanotransduction involves the transmission of force from the extracellular matrix to the cell nucleus, where it affects nucleocytoplasmic transport (NCT) and the subsequent nuclear localization of transcriptional regulators, such as YAP (also known as YAP1). However, if and how NCT is mechanosensitive in multicellular systems is unclear. Here, we characterize and use a fluorescent sensor of nucleocytoplasmic transport (Sencyt) and demonstrate that NCT responds to mechanical forces but not cell density in cell monolayers. Using monolayers of both epithelial and mesenchymal phenotype, we show that NCT is altered in response both to osmotic shocks and to the inhibition of cell contractility. Furthermore, NCT correlates with the degree of nuclear deformation measured through nuclear solidity, a shape parameter related to nuclear envelope tension. In contrast, YAP is sensitive to cell density, showing that the YAP response to cell-cell contacts is not via a mere mechanical effect of NCT. Our results demonstrate the generality of the mechanical regulation of NCT.
Collapse
|
40
|
Hu J, Chen P, Zhang L, Sun P, Huang Y, Liu X, Fan Q. A universal optical apta sensor for antibiotics determination based on a new high-efficiency Förster resonance energy transfer pair. Mikrochim Acta 2024; 191:561. [PMID: 39180707 DOI: 10.1007/s00604-024-06629-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2024] [Accepted: 08/01/2024] [Indexed: 08/26/2024]
Abstract
A novel "turn-on" aptasensor for kanamycin (Kana) detection based on a new Förster resonance energy transfer (FRET) pair is reported. A new organic small molecule was employed as a high-efficiency quencher for fluorophore. Based on specific interactions between ssDNA and the quencher, an ingenious and amplified strategy was designed. In the absence of the target, the fluorescence of the fluorophore labeled at the end of the aptamer was quenched. After the binding of the aptamer to the target, the fluorescence was recovered and amplified. The proposed aptasensor showed high specificity, selectivity, and stability in complicated systems. With the P3-based strategy, the limit of detection for Kana is estimated to be 10 nM, which is much lower than the maximum allowable concentration in milk. The recoveries of spiked Kana in milk were in the range 99.8 ~ 105.3% (n = 3). Fortunately, this novel method can be easily extended to other antibiotics such as tobramycin by simply replacing the aptamer, showing great potential as a universal platform for selective, sensitive, and rapid detection of hazardous analytes in food samples.
Collapse
|
41
|
Clephas PRD, Zwartkruis VW, Malgie J, van Gent MWF, Brunner-La Rocca HP, Szymanski MK, van Halm VP, Handoko ML, Kok WEM, Asselbergs FW, van Kimmenade RRJ, Manintveld OC, van Mieghem NMDA, Beeres SLMA, Post MC, Borleffs CJW, Tukkie R, Mosterd A, Linssen GCM, Spee RF, Emans ME, Smilde TDJ, van Ramshorst J, Kirchhof CJHJ, Feenema-Aardema MW, da Fonseca CA, van den Heuvel M, Hazeleger R, van Eck M, van Heerebeek L, Boersma E, Rienstra M, de Boer RA, Brugts JJ. Pulmonary artery pressure monitoring in chronic heart failure: effects across clinically relevant subgroups in the MONITOR-HF trial. Eur Heart J 2024; 45:2954-2964. [PMID: 38733175 PMCID: PMC11335373 DOI: 10.1093/eurheartj/ehae323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Revised: 05/03/2024] [Accepted: 05/09/2024] [Indexed: 05/13/2024] Open
Abstract
BACKGROUND AND AIMS In patients with chronic heart failure (HF), the MONITOR-HF trial demonstrated the efficacy of pulmonary artery (PA)-guided HF therapy over standard of care in improving quality of life and reducing HF hospitalizations and mean PA pressure. This study aimed to evaluate the consistency of these benefits in relation to clinically relevant subgroups. METHODS The effect of PA-guided HF therapy was evaluated in the MONITOR-HF trial among predefined subgroups based on age, sex, atrial fibrillation, diabetes mellitus, left ventricular ejection fraction, HF aetiology, cardiac resynchronization therapy, and implantable cardioverter defibrillator. Outcome measures were based upon significance in the main trial and included quality of life-, clinical-, and PA pressure endpoints, and were assessed for each subgroup. Differential effects in relation to the subgroups were assessed with interaction terms. Both unadjusted and multiple testing adjusted interaction terms were presented. RESULTS The effects of PA monitoring on quality of life, clinical events, and PA pressure were consistent in the predefined subgroups, without any clinically relevant heterogeneity within or across all endpoint categories (all adjusted interaction P-values were non-significant). In the unadjusted analysis of the primary endpoint quality-of-life change, weak trends towards a less pronounced effect in older patients (Pinteraction = .03; adjusted Pinteraction = .33) and diabetics (Pinteraction = .01; adjusted Pinteraction = .06) were observed. However, these interaction effects did not persist after adjusting for multiple testing. CONCLUSIONS This subgroup analysis confirmed the consistent benefits of PA-guided HF therapy observed in the MONITOR-HF trial across clinically relevant subgroups, highlighting its efficacy in improving quality of life, clinical, and PA pressure endpoints in chronic HF patients.
Collapse
|
42
|
Li H, Wang Q, Han L, Chen Z, Wang G, Wang Q, Ma S, Ai B, Xi G. Quality characterization of tobacco flavor and tobacco leaf position identification based on homemade electronic nose. Sci Rep 2024; 14:19229. [PMID: 39164410 PMCID: PMC11336110 DOI: 10.1038/s41598-024-70180-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Accepted: 08/13/2024] [Indexed: 08/22/2024] Open
Abstract
A set of nine unique tobacco extract samples was analyzed using a self-developed electronic nose (E-nose) system, a commercial E-nose, and gas chromatography-mass spectrometry (GC-MS). The evaluation employed principal component analysis, statistical quality control, and soft independent modeling of class analogies (SIMCA). These multifaceted statistical methods scrutinized the collected data. Subsequently, a quality control model was devised to assess the stability of the sample quality. The results showed that the custom E-nose system could successfully distinguish between tobacco extracts with similar odors. After further training and the development of a quality control model for accepted tobacco extracts, it was possible to identify samples with normal and abnormal quality. To further validate our E-nose and extend its use within the tobacco industry, we collected and accurately classified the flavors of different tobacco leaf positions, with a remarkable accuracy rate of 0.9744. This finding facilitates the practical application of our E-nose system for the efficient identification of tobacco leaf positions.
Collapse
|
43
|
Rahmatnejad V, Tolosa M, Ge X, Rao G. Completely noninvasive multi-analyte monitoring system for cell culture processes. Biotechnol Lett 2024:10.1007/s10529-024-03521-z. [PMID: 39162863 DOI: 10.1007/s10529-024-03521-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2024] [Revised: 06/20/2024] [Accepted: 08/03/2024] [Indexed: 08/21/2024]
Abstract
Although online monitoring of dissolved O2, pH, and dissolved CO2 is critical in bioprocesses, nearly all existing technologies require some level of direct contact with the cell culture environment, posing risks of contamination. This study addresses the need for an accurate, and completely noninvasive technique for simultaneous measurement of these analytes. A "non-contact" technique for simultaneous monitoring of dissolved O2, pH, and dissolved CO2 was developed. Instead of direct contact with the culture media, the measurements were made through permeable membranes via either a sampling port in the culture vessel wall or a flow cell. The efficacy of the "non-contact" technique was validated in Escherichia coli (E.coli), Chinese hamster ovary (CHO) culture processes, and dynamic environments created by sparging gases in cell culture medium. The measurements obtained through the developed techniques were comparable to those obtained through control methods. The noninvasive monitoring system can offer accurate, and contamination-minimized monitoring of critical process parameters including dissolved O2, pH, and dissolved CO2. These advancements will enhance the control and optimization of cell culture processes, promising improved cell culture performance.
Collapse
|
44
|
Genc HN, Guctekin Yasar O, Boran T, Karuk Elmas SN, Arslan FN, Yilmaz I, Sirit A. Selective Chromo-Fluorogenic Chemoprobe for nM Al 3+ Recognition: Experimental and Living-Cell Applications. J Fluoresc 2024:10.1007/s10895-024-03904-5. [PMID: 39158625 DOI: 10.1007/s10895-024-03904-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2024] [Accepted: 08/02/2024] [Indexed: 08/20/2024]
Abstract
A rhodamine based chemoprobe BESN was engineered and employed as a selective ''OFF-ON'' chromo-fluorogenic sensor for Al3+ in H2O:MeOH (1:9, v:v). Notable changes in the absorption and emission spectra of BESN were clearly detectable upon the addition of Al3+. Sensitivity and binding mechanism studies demonstrated a good sensing performance of BESN with nanomolar detection limit (130 nM), and it was found to be highly selective towards interfering metal ions. Besides, the binding constant between BESN and Al3+ was found to be 3.19 × 103 M-1. Then, the validation study of BESN for Al3+ was performed based on significant analytical parameters and statistical tests. The binding of Al3+ with BESN (1:1) was probed via infrared, high-resolution mass and emission (Job's plot) spectroscopy measurements. The sensing performance of BESN could make it ideal chemosensor for real applications including vegetable, tuna fish and water samples, also for Smartphone and test-kit applications. The recovery values of the BESN to Al3+ were estimated within a range from 95.13% to 105.30% for water, 94.63% to 109.62% for tuna fish and 94.80% to 109.80% for vegetable samples. Additionally, the BESN has very low cytotoxicity and was triumphantly utilized for the recognition of Al3+ in living-cells.
Collapse
|
45
|
Cao Y, Song Y, Fan X, Ma L, Feng T, Zeng J, Xue C, Xu J. A smartphone-assisted portable sensing hydrogel modules based on UCNPs and Co 3O 4 NPs for fluorescence quantitation of hypoxanthine in aquatic products. Talanta 2024; 276:126259. [PMID: 38761664 DOI: 10.1016/j.talanta.2024.126259] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Revised: 04/23/2024] [Accepted: 05/12/2024] [Indexed: 05/20/2024]
Abstract
Hypoxanthine is a promising index for evaluating the freshness of various aquatic products. Combined the hydrogels containing upconversion nanoparticles (UCNPs), Co3O4 NPs, and N-ethyl-N-(3-sulfopropyl)-3-methylaniline sodium salt/4-amino-antipyrine (TOPS/4-AAP) with a smartphone, a portable sensor was developed for the convenient, sensitive detection of hypoxanthine. With the H2O2 from xanthine oxidase (XOD)-catalyzed reactions of hypoxanthine, the fluorescence of UCNPs was effectively quenched by the purple product produced from the oxidization of TOPS/4-AAP catalyzed by Co3O4 NPs exhibiting peroxidase activity, among which the color change could be transformed into digital signals for quantification of hypoxanthine. The Green value in the RGB analysis of the fluorescence image was negatively proportional to hypoxanthine concentration in the range of 2.5-20 mg/L with a detection limit of 0.69 mg/L and a quantitation limit of 2.30 mg/L. Finally, this sensor was applied for hypoxanthine detection in real aquatic products, showing potential application for freshness evaluation of aquatic products.
Collapse
|
46
|
He P, Chen Y, Lin L, Guo H, Yang F. A "turn-on" fluorescent sensor for herbicide quizalofop-p-ethyl based on cyanostilbene-pyridine macrocycle. Talanta 2024; 276:126269. [PMID: 38776773 DOI: 10.1016/j.talanta.2024.126269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 05/12/2024] [Accepted: 05/15/2024] [Indexed: 05/25/2024]
Abstract
Quizalofop-p-ethyl is a widely used herbicide that also poses a risk to human health and environmental safety. However, there is still a lack of simple and in-situ detecting method for quizalofop-p-ethyl so far. In this work, the fluorescent sensor was firstly developed on detection of quizalofop-p-ethyl based on cyanostilbene-pyridine macrocycle (CPM). CPM was prepared by the "1 + 1" condensation of pyridine-substituted cyanostilbene derivative with 4,4'-Bis(chloromethyl)biphenyl in 68 % yield. The weak fluorescence of CPM in aqueous media transferred to strong orange fluorescence after sensing quizalofop-p-ethyl. This sensing behavior exhibited high selectivity among 28 kinds of herbicides and ions. The limitation of detection (LOD) was 2.98 × 10-8 M and the limitation of quantification (LOQ) was 9.94 × 10-8 M (λex = 390 nm, λem = the maximum emission between 512 nm and 535 nm) with a dynamic range of 0.01-0.9 eq. The binding constant (Ka) of quizalofop-p-ethyl to the sensor CPM was 3.2 × 106 M-1. The 1:1 sensing mechanism was confirmed as that quizalofop-p-ethyl was located in the cavity of CPM, which enhanced aggregating effect and reduced the intramolecular rotation of aromatic groups for better AIE effect. The sensing ability of CPM for quizalofop-p-ethyl had been efficiently applied in test paper experiments, agricultural product tests and real water samples, revealing that CPM has good application prospect for simple and in-situ detection of quizalofop-p-ethyl in real environment.
Collapse
|
47
|
Matos T, Martins MS, Henriques R, Goncalves LM. Design of a sensor to estimate suspended sediment transport in situ using the measurements of water velocity, suspended sediment concentration and depth. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 365:121660. [PMID: 38963965 DOI: 10.1016/j.jenvman.2024.121660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2023] [Revised: 06/06/2024] [Accepted: 06/29/2024] [Indexed: 07/06/2024]
Abstract
- The sediment transport plays a major role in every aquatic ecosystem. However, the lack of instruments to monitor this process has been an obstacle to understanding its effects. We present the design of a single sensor built to measure water velocity, suspended sediment concentration and depth in situ, and how to associate the three variables to estimate and analyse sediment transport. During the laboratory calibrations, the developed instrument presented a resolution from 0.001 g/L to 0.1 g/L in the 0-12 g/L range for the measurement of suspended sediment concentration and 0.05 m/s resolution for 0-0.5 m/s range and 0.001 m/s resolution for 0.5-1 m/s range for the measurement of water velocity. The device was deployed for 6 days in an estuarine area with high sediment dynamics to evaluate its performance. During the field experiment, the sensor successfully measured the tidal cycles and consequent change of flow directions, and the suspended sediment concentration in the area. These measurements allowed to estimate water discharge and sediment transport rates during the different phases of tides, and the daily total volume of water and total amount of sediment passing through the estuary.
Collapse
|
48
|
Li C, Guo X, Zhou Y, Zhou FL, Li Y, Wu S, Jerrams S, Chen S, Jiang L. Biodegradable poly(lactic acid) blocked polyurethane/carbon nanotubes coated cotton fabric prepared by ultrasonic-assisted inkjet printing for high performance strain sensors. Int J Biol Macromol 2024; 274:133269. [PMID: 38906353 DOI: 10.1016/j.ijbiomac.2024.133269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 05/12/2024] [Accepted: 06/18/2024] [Indexed: 06/23/2024]
Abstract
In order to fulfill the demands for degradability, a broad working range, and heightened sensitivity in flexible sensors, biodegradable polyurethane (BTPU) was synthesized and combined with CNTs to produce BTPU/CNTs coated cotton fabric using an ultrasonic-assisted inkjet printing process. The synthesized BTPU displayed a capacity for degradation in a phosphate buffered saline solution, resulting in a weight loss of 25 % after 12 weeks of degradation. The BTPU/CNTs coated cotton fabric sensor achieved an extensive strain sensing range of 0-137.5 %, characterized by high linearity and a notable sensitivity (gauge factor (GF) of 126.8). Notably, it demonstrated a low strain detection limit (1 %), rapid response (within 280 ms), and robust durability, enabling precise monitoring of both large and subtle human body movements such as finger, wrist, neck, and knee bending, as well as swallowing. Moreover, the BTPU/CNTs coated cotton fabric exhibited favorable biocompatibility with human epidermis, enabling potential applications as wearable skin-contact sensors. This work provides insight into the development of degradable and high sensing performance sensors suitable for applications in electronic skins and health monitoring devices.
Collapse
|
49
|
Wang H, Zou H, Wang F. Construction of Multiply Guaranteed DNA Sensors for Biological Sensing and Bioimaging Applications. Chembiochem 2024; 25:e202400266. [PMID: 38801028 DOI: 10.1002/cbic.202400266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Revised: 05/25/2024] [Accepted: 05/27/2024] [Indexed: 05/29/2024]
Abstract
Nucleic acids exhibit exceptional functionalities for both molecular recognition and catalysis, along with the capability of predictable assembly through strand displacement reactions. The inherent programmability and addressability of DNA probes enable their precise, on-demand assembly and accurate execution of hybridization, significantly enhancing target detection capabilities. Decades of research in DNA nanotechnology have led to advances in the structural design of functional DNA probes, resulting in increasingly sensitive and robust DNA sensors. Moreover, increasing attention has been devoted to enhancing the accuracy and sensitivity of DNA-based biosensors by integrating multiple sensing procedures. In this review, we summarize various strategies aimed at enhancing the accuracy of DNA sensors. These strategies involve multiple guarantee procedures, utilizing dual signal output mechanisms, and implementing sequential regulation methods. Our goal is to provide new insights into the development of more accurate DNA sensors, ultimately facilitating their widespread application in clinical diagnostics and assessment.
Collapse
|
50
|
Wu J, Wang X, Li X, Zhu Z, Cui Z, Zhang T, Zou W, Han G. A dual-labeling molecule for efficient drug discovery of mitochondrial-lysosomal interactions. Mol Cell Probes 2024; 76:101968. [PMID: 38960210 DOI: 10.1016/j.mcp.2024.101968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Revised: 06/20/2024] [Accepted: 07/01/2024] [Indexed: 07/05/2024]
Abstract
The close association between organelle interactions, such as mitochondrial-lysosomal interactions, and various diseases, including tumors, remains a challenge for drug discovering and identification. Conventional evaluation methods are often complex and multistep labeling procedures often generate false positives, such as cell damage. To overcome these limitations, we employed a single dual-color reporting molecule called Coupa, which labels mitochondria and lysosomes as blue and red, respectively. This facilitates the evaluation and discovering of drugs targeting mitochondria-lysosome contact (MLC). Using Coupa, we validated the effectiveness of various known antitumor drugs in intervening MLC by assessing their effect on key aspects, such as status, localization, and quantity. This provides evidence for the accuracy and applicability of our dual-color reporting molecule. Notably, we observed that several structural isomers of drugs, including Urolithin (A/B/C), exhibited distinct effects on MLC. In addition, Verteporfin and TEAD were found to induce anti-tumor effects by controlling MLC at the organelle level, suggesting a potential new mechanism of action. Collectively, Coupa offers a novel scientific tool for discovering drugs that target mitochondrial-lysosomal interactions. It not only distinguished the differential effects of structurally similar drugs on the same target, but also reveals new mechanisms underlying the reported antitumor properties of existing drugs. Ultimately, our findings contribute to the advancement of drug discovery and provide valuable insights into the complex interactions between organelles in a disease context.
Collapse
|