26
|
Ochando-Pulido JM, Martinez-Ferez A. Novel micro/ultra/nanocentrifugation membrane process assessment for revalorization and reclamation of agricultural wastewater. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2018; 222:447-453. [PMID: 29894948 DOI: 10.1016/j.jenvman.2018.05.092] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2017] [Revised: 12/18/2017] [Accepted: 05/27/2018] [Indexed: 06/08/2023]
Abstract
The concentration and recovery of the high-added value phenolic fraction from two-phase olive mill wastewater and the simultaneous effluent treatment by a novel micro/ultra/nanocentrifugation membrane process assessment is addressed, permitting to gather information for a correct and effective screening procedure for the adequate membrane election (MF-UF-loose NF) for the target. Phenolic compounds are the major factor of phytotoxicity of these effluents, but on the other hand they present high antioxidant properties that makes them very relevant for food, cosmetic, pharmaceutical and biotechnological industries. The selection of a membrane MWCO between 100 kDa and 0.45 μm permitted the complete transfer of the phenolic fraction to the permeate, whereas below 3 kDa they would be transferred to the concentrate stream instead, with ∼60% COD reduction and EC lowered to 551-662 μS cm-1 in the final treated stream ensured, sensibly improving the effluent quality. This would provide a purified effluent with good salinity standards according to the indications given by the FAO for irrigation reuse. This procedure could be quick and reliable for the assessment of the adequate membrane needed for a particular purification process, in contrast with long-term, time consuming common bench-scale procedures.
Collapse
|
27
|
Almuktar SAAAN, Abed SN, Scholz M. Wetlands for wastewater treatment and subsequent recycling of treated effluent: a review. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2018; 25:23595-23623. [PMID: 29959736 PMCID: PMC6096557 DOI: 10.1007/s11356-018-2629-3] [Citation(s) in RCA: 93] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/25/2018] [Accepted: 06/20/2018] [Indexed: 05/23/2023]
Abstract
Due to water scarcity challenges around the world, it is essential to think about non-conventional water resources to address the increased demand in clean freshwater. Environmental and public health problems may result from insufficient provision of sanitation and wastewater disposal facilities. Because of this, wastewater treatment and recycling methods will be vital to provide sufficient freshwater in the coming decades, since water resources are limited and more than 70% of water are consumed for irrigation purposes. Therefore, the application of treated wastewater for agricultural irrigation has much potential, especially when incorporating the reuse of nutrients like nitrogen and phosphorous, which are essential for plant production. Among the current treatment technologies applied in urban wastewater reuse for irrigation, wetlands were concluded to be the one of the most suitable ones in terms of pollutant removal and have advantages due to both low maintenance costs and required energy. Wetland behavior and efficiency concerning wastewater treatment is mainly linked to macrophyte composition, substrate, hydrology, surface loading rate, influent feeding mode, microorganism availability, and temperature. Constructed wetlands are very effective in removing organics and suspended solids, whereas the removal of nitrogen is relatively low, but could be improved by using a combination of various types of constructed wetlands meeting the irrigation reuse standards. The removal of phosphorus is usually low, unless special media with high sorption capacity are used. Pathogen removal from wetland effluent to meet irrigation reuse standards is a challenge unless supplementary lagoons or hybrid wetland systems are used.
Collapse
|
28
|
Ochando-Pulido JM, Martinez-Ferez A. Operation setup of a nanofiltration membrane unit for purification of two-phase olives and olive oil washing wastewaters. THE SCIENCE OF THE TOTAL ENVIRONMENT 2018; 612:758-766. [PMID: 28866403 DOI: 10.1016/j.scitotenv.2017.08.287] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2017] [Revised: 08/28/2017] [Accepted: 08/29/2017] [Indexed: 06/07/2023]
Abstract
In this research work, the purification of olives and olive oil washing wastewaters from two-phase extraction mills by a novel polymeric NF membrane is addressed. The effluent was previously subjected to a physicochemical secondary-tertiary treatment previously optimized at pilot and industrial scales. Within the adequate operating conditions, suspended solids could be completely removed, and the EC was considerable lowered down to good quality values acceptable for irrigation purposes (1.9-2.0mScm-1), whereas the chemical oxygen demand was reduced below 31.9mgL-1. The standards for discharging in public waterways or reusing the final treated effluent for irrigation with acceptable quality were therefore accomplished. Moreover, the performance of the NF membrane ranged between 2.82 and 6.96Lh-1m-2bar-1, that is, a flux of up to 160Lh-1m-2 at 25bar. Furthermore, the 15-minute acid cleaning plus 15-minute alkaline/detergent cleaning could recover satisfactorily the permeability of the membrane. The necessary overdesign of the membrane operation was estimated as 9.42-17.53%, which meant a maximum required membrane area of 61.82m2. Hence, just 2 membrane modules should be implemented in a medium-sized mill to engineer the operation, boosting the economic feasibility of the proposed process both from operational and capital costs point of views.
Collapse
|
29
|
Ochando-Pulido JM, Martinez-Ferez A. Experimental design optimization of reverse osmosis purification of pretreatedolive mill wastewater. THE SCIENCE OF THE TOTAL ENVIRONMENT 2017; 587-588:414-422. [PMID: 28256318 DOI: 10.1016/j.scitotenv.2017.02.045] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/31/2016] [Revised: 01/19/2017] [Accepted: 02/05/2017] [Indexed: 06/06/2023]
Abstract
The management of the effluents generated by olive oil industries, commonly known as olive mills, represents an ever increasing problem still unresolved. The core of the present work was the modelling and optimization of a reverse osmosis (RO) membrane operation for the purification of a tertiary-treated olive mill wastewater stream (OMW2TT). Statistical multifactorial analysis showed all the studied variables including the operating pressure (PTM), crossflow velocity (vt) and operating temperature (T) remarkably influence the permeate flux yielded by the selected membrane (p-value practically equal to zero), confirming a statistically significant relationship among the variables considered at 95% confidence level. However, PTM and T exhibit a deeper influence than vt, according to the p-values withdrawn from the analysis, being the squared effects significant too, but more in case of the former ones. The obtained contour plots and response surface support the former results. In particular, the optimized parameters were ambient temperature range (24-29.6°C), moderate operating pressure (31.5-35bar) and turbulent crossflow (4.1-5.1ms-1). In the end, the quality standards to reuse the purified effluent for irrigation purposes and discharge to sewers were stably ensured.
Collapse
|
30
|
Gomes J, Costa R, Quinta-Ferreira RM, Martins RC. Application of ozonation for pharmaceuticals and personal care products removal from water. THE SCIENCE OF THE TOTAL ENVIRONMENT 2017; 586:265-283. [PMID: 28185729 DOI: 10.1016/j.scitotenv.2017.01.216] [Citation(s) in RCA: 183] [Impact Index Per Article: 26.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/17/2016] [Revised: 01/30/2017] [Accepted: 01/31/2017] [Indexed: 06/06/2023]
Abstract
Due to the shortening on natural water resources, reclaimed wastewater will be an important water supply source. However, suitable technologies must be available to guaranty its proper detoxification with special concern for the emerging pharmaceutical and personal care products that are continuously reaching municipal wastewater treatment plants. While conventional biological systems are not suitable to remove these compounds, ozone, due to its interesting features involving molecular ozone oxidation and the possibility of generating unselective hydroxyl radicals, has a wider range of action on micropollutants removal and water disinfection. This paper aims to review the studies dealing with ozone based processes for water reuse by considering municipal wastewater reclamation as well as natural and drinking water treatment. A comparison with alternative technologies is given. The main drawback of ozonation is related with the low mineralization achieved that may lead to the production of reaction intermediates with toxic features. The use of hydrogen peroxide and light aided systems enhance ozone action over pollutants. Moreover, scientific community is focused on the development of solid catalysts able to improve the mineralization level achieved by ozone. Special interest is now being given to solar light catalytic ozonation systems with interesting results both for chemical and biological contaminants abatement. Nowadays the integration between ozonation and sand biofiltration seems to be the most interesting cost effective methodology for water treatment. However, further studies must be performed to optimize this system by understanding the biofiltration mechanisms.
Collapse
|
31
|
Starling MCVM, Dos Santos PHR, de Souza FAR, Oliveira SC, Leão MMD, Amorim CC. Application of solar photo-Fenton toward toxicity removal and textile wastewater reuse. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2017; 24:12515-12528. [PMID: 27566160 DOI: 10.1007/s11356-016-7395-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2016] [Accepted: 08/04/2016] [Indexed: 06/06/2023]
Abstract
Solar photo-Fenton represents an innovative and low-cost option for the treatment of recalcitrant industrial wastewater, such as the textile wastewater. Textile wastewater usually shows high acute toxic and variability and may be composed of many different chemical compounds. This study aimed at optimizing and validating solar photo-Fenton treatment of textile wastewater in a semi-pilot compound parabolic collector (CPC) for toxicity removal and wastewater reclamation. In addition, treated wastewater reuse feasibility was investigated through pilot tests. Experimental design performed in this study indicated optimum condition for solar photo-Fenton reaction (20 mg L-1 of Fe2+ and 500 mg L-1 of H2O2; pH 2.8), which achieved 96 % removal of dissolved organic carbon (DOC) and 99 % absorbance removal. A toxicity peak was detected during treatment, suggesting that highly toxic transformation products were formed during reaction. Toxic intermediates were properly removed during solar photo-Fenton (SPF) treatment along with the generation of oxalic acid as an ultimate product of degradation and COS increase. Different samples of real textile wastewater were treated in order to validate optimized treatment condition with regard to wastewater variability. Results showed median organic carbon removal near 90 %. Finally, reuse of treated textile wastewater in both dyeing and washing stages of production was successful. These results confirm that solar photo-Fenton, as a single treatment, enables wastewater reclamation in the textile industry. Graphical abstract Solar photo-Fenton as a revolutionary treatment technology for "closing-the-loop" in the textile industry.
Collapse
|
32
|
Lee S, Ihara M, Yamashita N, Tanaka H. Improvement of virus removal by pilot-scale coagulation-ultrafiltration process for wastewater reclamation: Effect of optimization of pH in secondary effluent. WATER RESEARCH 2017; 114:23-30. [PMID: 28226246 DOI: 10.1016/j.watres.2017.02.017] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2016] [Revised: 02/02/2017] [Accepted: 02/07/2017] [Indexed: 05/09/2023]
Abstract
Reclaimed water (i.e., reused advanced-treated wastewater) offers an alternative water resource. To reduce the health risks associated with its use, efficient virus removal such as with advanced wastewater treatment processes is important. Virus removal by coagulation followed by ultrafiltration (UF) for the treatment of drinking water has been well examined. But its efficacy in wastewater reclamation purpose using secondary treated effluent (SE) from wastewater treatment plant (WWTP) as feed water is unclear. Here, we optimized the virus removal efficiency of coagulation-UF in pilot-scale wastewater reclamation plants using SE as feed water, using the F-specific RNA bacteriophage MS2 as a model virus, at two wastewater treatment plants in Japan. We investigated how using coagulation as a pretreatment for UF improved virus removal efficiency. The efficiency varied greatly between SEs. To reveal the cause of the variation, we conducted laboratory-scale batch coagulation experiments. The efficiency of viral coagulation was negatively correlated with the concentration of dissolved organic matter in the feed water. The optimum pH for coagulation differed between SEs, and the efficiency of coagulation could be dramatically improved by optimizing the pH. We confirmed that the virus removal efficiency in the pilot-scale facility actually could be improved by adjusting the pH. In addition, we confirmed that coagulation-sedimentation-UF with pH adjustment could operate stably for more than 30 days at the pilot scale, with a high virus removal rate. Thus, the wastewater reclamation process described here offers promise in terms of reduced health risks and practical operation.
Collapse
|
33
|
Yu T, Meng L, Zhao QB, Shi Y, Hu HY, Lu Y. Effects of chemical cleaning on RO membrane inorganic, organic and microbial foulant removal in a full-scale plant for municipal wastewater reclamation. WATER RESEARCH 2017; 113:1-10. [PMID: 28183034 DOI: 10.1016/j.watres.2017.01.068] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2016] [Revised: 01/26/2017] [Accepted: 01/31/2017] [Indexed: 06/06/2023]
Abstract
Of all of the strategies for controlling reverse osmosis (RO) membrane fouling, chemical cleaning is indispensable. To study the effects of chemical cleaning on membrane foulant removal, a comparative analysis of RO membranes before and after common alkaline and acid cleaning was conducted by dissecting lead and terminal RO membranes in a full-scale municipal wastewater reclamation plant. Most foulants on the membranes were removed by chemical cleaning processes. Calcium was the major inorganic component of the foulants because of its highest concentration in the feed water. Aluminum and iron were also abundant elements on the membranes due to their high deposition ratios and low removal efficiencies. Hydrophilic neutrals (HIN) and hydrophobic neutrals (HON) were the two largest dissolved organic matter (DOM) fractions on the membranes before cleaning. HIN and hydrophilic acids (HIA) were not effectively removed. Chemical cleaning removed 94% and 90% of the total bacteria on the lead and tail membranes and considerably changed the structure of the microbial communities. Bacteria excessively producing extracellular polymeric substance (EPS), such as Pseudomonas and Zoogloea, were much more resistant to the chemical cleaning process. After cleaning, the membrane microbial community structures were more similar to those in the feed water than the structures on the membranes before cleaning. These results shed light on the effects of cleaning in a full-scale RO plant, improves our understanding of the removal of foulants and provides potential research directions for cleaning methods and RO pretreatment processes.
Collapse
|
34
|
Yen FC, You SJ, Chang TC. Performance of electrodialysis reversal and reverse osmosis for reclaiming wastewater from high-tech industrial parks in Taiwan: A pilot-scale study. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2017; 187:393-400. [PMID: 27836559 DOI: 10.1016/j.jenvman.2016.11.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2016] [Revised: 10/20/2016] [Accepted: 11/01/2016] [Indexed: 06/06/2023]
Abstract
Wastewater reclamation is considered an absolute necessity in Taiwan, as numerous industrial parks experience water shortage. However, the water quality of secondary treated effluents from sewage treatment plants generally does not meet the requirements of industrial water use because of the high inorganic constituents. This paper reports experimental data from a pilot-plant study of two treatment processes-(i) fiber filtration (FF)-ultrafiltration (UF)-reverse osmosis (RO) and (ii) sand filtration (SF)-electrodialysis reversal (EDR)-for treating industrial high conductivity effluents from the Xianxi wastewater treatment plant in Taiwan. The results demonstrated that FF-UF was excellent for turbidity removal and it was a suitable pretreatment process for RO. The influence of two membrane materials on the operating characteristics and process stability of the UF process was determined. The treatment performance of FF-UF-RO was higher than that of SF-EDR with an average desalination rate of 97%, a permeate conductivity of 272.7 ± 32.0, turbidity of 0.183 ± 0.02 NTU and a chemical oxigen demand of <4.5 mg/L. The cost analysis for both processes in a water reclamation plant of 4000 m3/d capacity revealed that using FF-UF-RO had a lower treatment cost than using SF-EDR, which required activated carbon filtration as a post treatment process. On the basis of the results in this study, the FF-UF-RO system is recommended as a potential process for additional applications.
Collapse
|
35
|
Cotillas S, Llanos J, Castro-Ríos K, Taborda-Ocampo G, Rodrigo MA, Cañizares P. Synergistic integration of sonochemical and electrochemical disinfection with DSA anodes. CHEMOSPHERE 2016; 163:562-568. [PMID: 27570213 DOI: 10.1016/j.chemosphere.2016.08.034] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2016] [Revised: 08/05/2016] [Accepted: 08/06/2016] [Indexed: 05/03/2023]
Abstract
This work focuses on the disinfection actual urban wastewater by the combination of ultrasound (US) irradiation and electrodisinfection with Dimensionally Stable Anodes (DSA). First, the inactivation of Escherichia coli (E. coli) during the sonochemical disinfection was studied at increasing ultrasound power. Results showed that it was not possible to achieve a complete disinfection, even at the highest US power (200 W) dosed by the experimental device used. Next, the electrodisinfection with DSA anodes at different current densities was studied, finding that it was necessary a minimum current density of 11.46 A m(-2) to reach the complete disinfection. Finally, an integrated sonoelectrodisinfection process was studied. Results showed a synergistic effect when coupling US irradiation with DSA electrodisinfection, with a synergy coefficient higher than 200% of the disinfection rate attained for the highest US power applied. In this process, hypochlorite and chloramines were identified as the main reagents for the disinfection process (neither chlorate nor perchlorate were detected), and the presence of trihalomethanes was far below acceptable values. Confirming this synergistic effect with DSA anodes opens the door to novel efficient disinfection processes, limiting the occurrence of hazardous disinfection by-products.
Collapse
|
36
|
Sun YX, Hu HY, Shi CZ, Yang Z, Tang F. Changes in the components and biotoxicity of dissolved organic matter in a municipal wastewater reclamation reverse osmosis system. ENVIRONMENTAL TECHNOLOGY 2016; 37:2149-2156. [PMID: 26803912 DOI: 10.1080/09593330.2016.1144795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2015] [Accepted: 01/16/2016] [Indexed: 06/05/2023]
Abstract
The characteristics of dissolved organic matter (DOM) and the biotoxicity of these components were investigated in a municipal wastewater reclamation reverse osmosis (mWRRO) system with a microfiltration (MF) pretreatment unit. The MF pretreatment step had little effect on the levels of dissolved organic carbon (DOC) in the secondary effluent, but the addition of chlorine before MF promoted the formation of organics with anti-estrogenic activity. The distribution of excitation emission matrix (EEM) fluorescence constituents exhibited obvious discrepancies between the secondary effluent and the reverse osmosis (RO) concentrate. Using size exclusion chromatography, DOM with low molecular weights of approximately 1.2 and 0.98 kDa was newly formed during the mWRRO. The normalized genotoxicity and anti-estrogenic activity of the RO concentrate were 32.1 ± 10.2 μg4-NQO/mgDOC and 0.36 ± 0.08 mgTAM/mgDOC, respectively, and these values were clearly higher than those of the secondary effluent and MF permeate. The florescence volume of Regions I and II in the EEM spectrum could be suggested as a surrogate for assessing the genotoxicity and anti-estrogenic activity of the RO concentrate.
Collapse
|
37
|
Pulido JMO. A review on the use of membrane technology and fouling control for olive mill wastewater treatment. THE SCIENCE OF THE TOTAL ENVIRONMENT 2016; 563-564:664-675. [PMID: 26472261 DOI: 10.1016/j.scitotenv.2015.09.151] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2015] [Revised: 09/29/2015] [Accepted: 09/29/2015] [Indexed: 06/05/2023]
Abstract
Olive mill effluents (OME) by-produced have significantly increased in the last decades as a result of the boost of the olive oil agro-industrial sector and due to the conversion into continuous operation centrifugation technologies. In these effluents, the presence of phytotoxic recalcitrant pollutants makes them resistant to biological degradation and thus inhibits the efficiency of biological and conventional processes. Many reclamation treatments as well as integrated processes for OME have already been proposed and developed but not led to completely satisfactory and cost-effective results. Olive oil industries in its current status, typically small mills dispersed, cannot afford such high treatment costs. Furthermore, conventional treatments are not able to abate the significant dissolved monovalent and divalent ions concentration present in OME. Within this framework, membrane technology offers high efficiency and moderate investment and maintenance expenses. Wastewater treatment by membrane technologies is growing in the recent years. This trend is owed to the fact of the availability of new membrane materials, membrane designs, membrane module concepts and general know-how, which have promoted credibility among investors. However, fouling reduces the membrane performances in time and leads to premature substitution of the membrane modules, and this is a problem of cost efficiency since wastewater treatment must imply low operating costs. Appropriate fouling inhibition methods should assure this result, thus making membrane processes for wastewater stream treatment both technically and economically feasible. In this paper, the treatment of the effluents by-produced in olive mills, generally called olive mill wastewaters, will be addressed. Within this context, the state of the art of the different pretreatments and integral membrane processes proposed up to today will be gathered and discussed, with an insight in the problem of fouling.
Collapse
|
38
|
Soto-Gómez D, Pérez-Rodríguez P, López-Periago JE, Paradelo M. Sepia ink as a surrogate for colloid transport tests in porous media. JOURNAL OF CONTAMINANT HYDROLOGY 2016; 191:88-98. [PMID: 27294674 DOI: 10.1016/j.jconhyd.2016.05.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2015] [Revised: 05/16/2016] [Accepted: 05/30/2016] [Indexed: 06/06/2023]
|
39
|
Sun YX, Yang Z, Ye T, Shi N, Tian Y. Evaluation of the treatment of reverse osmosis concentrates from municipal wastewater reclamation by coagulation and granular activated carbon adsorption. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2016; 23:13543-13553. [PMID: 27032632 DOI: 10.1007/s11356-016-6525-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Accepted: 03/21/2016] [Indexed: 06/05/2023]
Abstract
Reverse osmosis concentrate (ROC) from municipal wastewater reclamation reverse osmosis (mWRRO) contains elevated concentrations of contaminants which pose potential risks to aquatic environment. The treatment of ROC from an mWRRO using granular activated carbon (GAC) combined pretreatment of coagulation was optimized and evaluated. Among the three coagulants tested, ferric chloride (FeCl3) presented relatively higher DOC removal efficiency than polyaluminium chloride and lime at the same dosage and coagulation conditions. The removal efficiency of DOC, genotoxicity, and antiestrogenic activity concentration of the ROC could achieve 16.9, 18.9, and 39.7 %, respectively, by FeCl3 coagulation (with FeCl3 dosage of 180.22 mg/L), which can hardly reduce UV254 and genotoxicity normalized by DOC of the DOM with MW <5 kDa. However, the post-GAC adsorption column (with filtration velocity of 5.7 m/h, breakthrough point adsorption capacity of 0.22 mg DOC/g GAC) exhibited excellent removal efficiency on the dominant DOM fraction of MW <5 kDa in the ROC. The removal efficiency of DOC, UV254, and TDS in the ROC was up to 91.8, 96, and 76.5 %, respectively, by the FeCl3 coagulation and post-GAC adsorption. Also, the DOM with both genotoxicity and antiestrogenic activity were completely eliminated by the GAC adsorption. The results suggest that GAC adsorption combined pretreatment of FeCl3 coagulation as an efficient method to control organics, genotoxicity, and antiestrogenic activity in the ROC from mWRRO system.
Collapse
|
40
|
Wang WL, Wu QY, Huang N, Wang T, Hu HY. Synergistic effect between UV and chlorine (UV/chlorine) on the degradation of carbamazepine: Influence factors and radical species. WATER RESEARCH 2016; 98:190-8. [PMID: 27105033 DOI: 10.1016/j.watres.2016.04.015] [Citation(s) in RCA: 199] [Impact Index Per Article: 24.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Revised: 04/07/2016] [Accepted: 04/09/2016] [Indexed: 05/03/2023]
Abstract
For successful wastewater reclamation, advanced oxidation processes have attracted attention for elimination of emerging contaminants. In this study, the synergistic treatment with UV irradiation and chlorine (UV/chlorine) was used to degrade carbamazepine (CBZ). Neither UV irradiation alone nor chlorination alone could efficiently degraded CBZ. UV/chlorine oxidation showed a significant synergistic effect on CBZ degradation through generation of radical species (OH and Cl), and this process could be well depicted by pseudo first order kinetic. The degradation rate constants (kobs,CBZ) of CBZ increased linearly with increasing UV irradiance and chlorine dosage. The degradation of CBZ by UV/chlorine in acidic solutions was more efficient than that in basic solutions mainly due to the effect of pH on the dissociation of HOCl and OCl(-) and then on the quantum yields and radical species quenching of UV/chlorine. When pH was increased from 5.5 to 9.5, the rate constants of degradation of CBZ by OH decreased from 0.65 to 0.14 min(-1) and that by Cl decreased from 0.40 to 0.11 min(-1). The rate constant for the reaction between Cl and CBZ was 5.6 ± 1.6 × 10(10) M(-1) s(-1). Anions of HCO3(-) (1-50 mM) showed moderate inhibition of CBZ degradation by UV/chlorine, while Cl(-) did not. UV/chlorine could efficiently degrade CBZ in wastewater treatment plant effluent, although the degradation was inhibited by about 30% compared with that in ultrapure water with chlorine dosage of 0.14-0.56 mM. Nine main oxidation products of the CBZ degradation by UV/chlorine were identified using the HPLC-QToF MS/MS. Initial oxidation products arose from hydroxylation, carboxylation and hydrogen atom abstraction of CBZ by OH and Cl, and were then further oxidized to generate acylamino cleavage and decarboxylation products of acridine and acridione.
Collapse
|
41
|
Woo YC, Lee JJ, Shim WG, Shon HK, Tijing LD, Yao M, Kim HS. Effect of powdered activated carbon on integrated submerged membrane bioreactor-nanofiltration process for wastewater reclamation. BIORESOURCE TECHNOLOGY 2016; 210:18-25. [PMID: 26879205 DOI: 10.1016/j.biortech.2016.02.023] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2015] [Revised: 02/04/2016] [Accepted: 02/05/2016] [Indexed: 06/05/2023]
Abstract
The aim of this study was to determine the effect of powdered activated carbon (PAC) on the overall performance of a submerged membrane bioreactor (SMBR) system integrated with nanofiltration (NF) for wastewater reclamation. It was found that the trans-membrane pressure of SMBR increased continuously while that of the SMBR with PAC was more stable, mainly because water could still pass through the PACs and membrane even though foulants adhered on the PAC surface. The presence of PAC was able to mitigate fouling in SMBR as well as in NF. SMBR-NF with PAC obtained a higher flux of 8.1 LMH compared to that without PAC (6.6 LMH). In addition, better permeate quality was obtained with SMBR-NF integrated process added with PAC. The present results suggest that the addition of PAC in integrated SMBR-NF process could possibly lead to satisfying water quality and can be operated for a long-term duration.
Collapse
|
42
|
Qian-Yuan W, Chao L, Ye D, Wen-Long W, Huang H, Hong-Ying H. Elimination of disinfection byproduct formation potential in reclaimed water during solar light irradiation. WATER RESEARCH 2016; 95:260-267. [PMID: 27010786 DOI: 10.1016/j.watres.2016.02.023] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/14/2015] [Revised: 02/07/2016] [Accepted: 02/11/2016] [Indexed: 06/05/2023]
Abstract
Ecological storage of reclaimed water in ponds and lakes is widely applied in water reuse. During reclaimed water storage, solar light can degrade pollutants and improve water quality. This study investigated the effects of solar light irradiation on the disinfection byproduct formation potential in reclaimed water, including haloacetonitriles (HANs), trichloronitromethane (TCNM), trihalomethanes (THMs), haloketones (HKs) and chloral hydrate (CH). Natural solar light significantly decreased the formation potential of HANs, TCNM, and HKs in reclaimed water, but had a limited effect on the formation potential of THMs and CH. Ultraviolet (UV) light in solar radiation played a dominant role in the decrease of the formation potential of HANs, TCNM and HKs. Among the disinfection byproducts, the removal kinetic constant of dichloroacetonitrile (DCAN) with irradiation dose was much larger than those for dichloropropanone (1,1-DCP), trichloropropanone (1,1,1-TCP) and TCNM. During solar irradiation, fluorescence spectra intensities of reclaimed water also decreased significantly. The removal of tyrosine (Tyr)-like and tryptophan (Trp)-like protein fluorescence spectra intensity volumes was correlated to the decrease in DCAN formation potential. Solar irradiation was demonstrated to degrade Trp, Tyr and their DCAN formation potential. The photolysis products of Trp after solar irradiation were detected as kynurenine and tryptamine, which had chloroform, CH and DCAN formation potential lower than those of Trp.
Collapse
|
43
|
Sano D, Amarasiri M, Hata A, Watanabe T, Katayama H. Risk management of viral infectious diseases in wastewater reclamation and reuse: Review. ENVIRONMENT INTERNATIONAL 2016; 91:220-9. [PMID: 26985655 PMCID: PMC7111293 DOI: 10.1016/j.envint.2016.03.001] [Citation(s) in RCA: 99] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2015] [Revised: 03/04/2016] [Accepted: 03/05/2016] [Indexed: 05/18/2023]
Abstract
Inappropriate usage of reclaimed wastewater has caused outbreaks of viral infectious diseases worldwide. International and domestic guidelines for wastewater reuse stipulate that virus infection risks are to be regulated by the multiple-barrier system, in which a wastewater treatment process composed of sequential treatment units is designed based on the pre-determined virus removal efficiency of each unit. The objectives of this review were to calculate representative values of virus removal efficiency in wastewater treatment units based on published datasets, and to identify research topics that should be further addressed for improving implementation of the multiple-barrier system. The removal efficiencies of human noroviruses, rotaviruses and enteroviruses in membrane bioreactor (MBR) and conventional activated sludge (CAS) processes were obtained by a systematic review protocol and a meta-analysis approach. The log10 reduction (LR) of norovirus GII and enterovirus in MBR were 3.35 (95% confidence interval: 2.39, 4.30) and 2.71 (1.52, 3.89), respectively. The LR values of rotavirus, norovirus GI and GII in CAS processes were 0.87 (0.20, 1.53), 1.48 (0.96, 2.00) and 1.35 (0.52, 2.18), respectively. The systematic review process eliminated a substantial number of articles about virus removal in wastewater treatment because of the lack of information required for the meta-analysis. It is recommended that future publications should explicitly describe their treatment of left-censored datasets. Indicators, surrogates and methodologies appropriate for validating virus removal performance during daily operation of wastewater reclamation systems also need to be identified.
Collapse
|
44
|
Wu Q, Li C, Wang W, He T, Hu H, Du Y, Wang T. Removal of fluorescence and ultraviolet absorbance of dissolved organic matter in reclaimed water by solar light. J Environ Sci (China) 2016; 43:118-127. [PMID: 27155416 DOI: 10.1016/j.jes.2015.08.021] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2015] [Revised: 08/23/2015] [Accepted: 08/25/2015] [Indexed: 06/05/2023]
Abstract
Storing reclaimed water in lakes is a widely used method of accommodating changes in the consumption of reclaimed water during wastewater reclamation and reuse. Solar light serves as an important function in degrading pollutants during storage, and its effect on dissolved organic matter (DOM) was investigated in this study. Solar light significantly decreased the UV254 absorbance and fluorescence (FLU) intensity of reclaimed water. However, its effect on the dissolved organic carbon (DOC) value of reclaimed water was very limited. The decrease in the UV254 absorbance intensity and FLU excitation-emission matrix regional integration volume (FLU volume) of reclaimed water during solar light irradiation was fit with pseudo-first order reaction kinetics. The decrease of UV254 absorbance was much slower than that of the FLU volume. Ultraviolet light in solar light had a key role in decreasing the UV254 absorbance and FLU intensity during solar light irradiation. The light fluence-based removal kinetic constants of the UV254 and FLU intensity were independent of light intensity. The peaks of the UV254 absorbance and FLU intensity with an apparent molecular weight (AMW) of 100Da to 2000Da decreased after solar irradiation, whereas the DOC value of the major peaks did not significantly change.
Collapse
|
45
|
Pradhan S, Fan L, Roddick FA, Shahsavari E, Ball AS. Impact of salinity on organic matter and nitrogen removal from a municipal wastewater RO concentrate using biologically activated carbon coupled with UV/H2O2. WATER RESEARCH 2016; 94:103-110. [PMID: 26938495 DOI: 10.1016/j.watres.2016.02.046] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/23/2015] [Revised: 02/15/2016] [Accepted: 02/19/2016] [Indexed: 06/05/2023]
Abstract
The concentrate streams generated from reverse osmosis (RO)-based municipal wastewater reclamation processes contain organic substances and nutrients at elevated concentrations, posing environmental and health risks on their disposal to confined receiving environments such as bays. The impact of salinity (TDS at 7, 10 and 16 g/L) of a RO concentrate (ROC) on the treatment efficiency of a biological activated carbon (BAC) system after pre-oxidation with UV/H2O2 was characterised in terms of removal of organic matter and nitrogen species, and the bacterial communities. Organic matter removal was comparable for the ROC over the tested salinity range, with 45-49% of DOC and 70-74% of UVA254 removed by the combined treatment. However, removal in total nitrogen (TN) was considerably higher for the ROC at the high salinity (TDS ∼ 16 mg/L) compared with the low (∼7 g/L) and medium salinity (∼10 g/L). Effective nitrification with high ammonium removal (>90%) was achieved at all salinity levels, whereas greater denitrification (39%) was obtained at high salinity than low (23%) and medium salinity (27%) which might suggest that the bacterial communities contributing to the greater denitrification were more halotolerant. Microbiological characterisation using polymerase chain reaction-denaturing gradient gel electrophoresis (PCR-DGGE) and culture based techniques showed that diversified bacterial communities were present in the BAC system as evident from different 16S rDNA. The major bacterial groups residing on the BAC media belonged to Bacillus (Firmicutes), Pseudomonas (γ-Proteobacteria), and Rhodococcus (Actinobacteria) for all salinity levels, confirming that these microbial communities could be responsible for carbon and nitrogen removal at the different salinity levels. This has implications in understanding the effectiveness and robustness of the BAC system over the salinity range of the ROC and so would be useful for optimising the treatment efficiency of the BAC system.
Collapse
|
46
|
Tang F, Hu HY, Sun LJ, Sun YX, Shi N, Crittenden JC. Fouling characteristics of reverse osmosis membranes at different positions of a full-scale plant for municipal wastewater reclamation. WATER RESEARCH 2016; 90:329-336. [PMID: 26760485 DOI: 10.1016/j.watres.2015.12.028] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2015] [Revised: 12/08/2015] [Accepted: 12/16/2015] [Indexed: 06/05/2023]
Abstract
Membrane fouling is an important shortcoming limiting the efficiency and wide application of reverse osmosis (RO) technology. In this paper, RO membranes in a full-scale municipal wastewater reclamation plant were autopsied. From the lead to tail position RO membranes in RO system, both of organic and inorganic matters on membranes reduced gradually. The higher ion products in RO concentrate didn't result in more serious inorganic scaling on the last position RO membranes, which was contrast with some other researches. Fe, Ca and Mg were major inorganic elements. Fe had a relatively low concentration in RO influent but the highest content on membranes. However, there was no specific pretreatment in terms of Fe removal. Ca and Mg scaling was controlled by the antiscalants injected. Organic fouling (75.0-84.5% of dry weights) was major problem on RO membranes due to the large amount of dissolved organic matters in secondary effluent as raw water. Hydrophilic acid (HIA, 48.0% of total DOC), hydrophobic acid (HOA, 23.6%) and hydrophobic neutral (HON, 19.0%) fraction was largest among the six fractions in RO influent, while HON (38.2-51.1%) and HOA (22.1-26.1%) tended to accumulate on membranes in higher quantities. Monitoring HON and HOA might help to forecast organic fouling.
Collapse
|
47
|
Li Y, Xiong W, Zhang W, Wang C, Wang P. Life cycle assessment of water supply alternatives in water-receiving areas of the South-to-North Water Diversion Project in China. WATER RESEARCH 2016; 89:9-19. [PMID: 26619399 DOI: 10.1016/j.watres.2015.11.030] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2015] [Revised: 11/09/2015] [Accepted: 11/13/2015] [Indexed: 06/05/2023]
Abstract
To alleviate the water shortage in northern China, the Chinese government launched the world's largest water diversion project, the South-to-North Water Diversion Project (SNWDP), which delivers water from water-sufficient southern China to water-deficient northern China. However, an up-to-date study has not been conducted to determine whether the project is a favorable option to augment the water supply from an environmental perspective. The life cycle assessment (LCA) methodology integrated with a freshwater withdrawal category (FWI) was adopted to compare water supply alternatives in the water-receiving areas of the SNWDP, i.e., water diversion, wastewater reclamation and seawater desalination. Beijing, Tianjin, Jinan and Qingdao were studied as representative cities because they are the primary water-receiving areas of the SNWDP. The results revealed that the operation phase played the dominant role in all but one of the life cycle impact categories considered and contributed to more than 70% of their scores. For Beijing and Tianjin, receiving water through the SNWDP is the most sustainable option to augment the water supply. The result can be drawn in all of the water-receiving areas of the middle route of the SNWDP. For Jinan and Qingdao, the most sustainable option is the wastewater reclamation system. The seawater desalination system obtains the highest score of the standard impact indicators in all of the study areas, whereas it is the most favorable water supply option when considering the freshwater withdrawal impact. Although the most sustainable water supply alternative was recommended through an LCA analysis, multi-water resources should be integrated into the region's water supply from the perspective of water sustainability. The results of this study provide a useful recommendation on the management of water resources for China.
Collapse
|
48
|
Luckmann J, Grethe H, McDonald S. When water saving limits recycling: Modelling economy-wide linkages of wastewater use. WATER RESEARCH 2016; 88:972-980. [PMID: 26624230 DOI: 10.1016/j.watres.2015.11.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2015] [Revised: 10/26/2015] [Accepted: 11/02/2015] [Indexed: 06/05/2023]
Abstract
The reclamation of wastewater is an increasingly important water source in parts of the world. It is claimed that wastewater recycling is a cheap and reliable form of water supply, which preserves water resources and is economically efficient. However, the quantity of reclaimed wastewater depends on water consumption by economic agents connected to a sewage system. This study uses a Computable General Equilibrium (CGE) model to analyse such a cascading water system. A case study of Israel shows that failing to include this linkage can lead to an overestimation of the potential of wastewater recycling, especially when economic agents engage in water saving.
Collapse
|
49
|
Pradhan S, Fan L, Roddick FA. Removing organic and nitrogen content from a highly saline municipal wastewater reverse osmosis concentrate by UV/H2O2-BAC treatment. CHEMOSPHERE 2015; 136:198-203. [PMID: 26002159 DOI: 10.1016/j.chemosphere.2015.05.028] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2015] [Revised: 05/07/2015] [Accepted: 05/12/2015] [Indexed: 05/23/2023]
Abstract
Reverse osmosis (RO) concentrate (ROC) streams generated from RO-based municipal wastewater reclamation processes pose potential health and environmental risks on their disposal to confined water bodies such as bays. A UV/H2O2 advanced oxidation process followed by a biological activated carbon (BAC) treatment was evaluated at lab-scale for the removal of organic and nutrient content from a highly saline ROC (TDS 16 g L(-1), EC 23.5 mS cm(-1)) for its safe disposal to the receiving environment. Over the 230-day operation of the UV/H2O2-BAC process, the colour and UV absorbance (254 nm) of the ROC were reduced to well below those of the influent to the reclamation process. The concentrations of DOC and total nitrogen (TN) were reduced by approximately 60% at an empty bed contact time (EBCT) of 60 min. The reduction in ammonia nitrogen by the BAC remained high under all conditions tested (>90%). Further investigation confirmed that the presence of residual peroxide in the UV/H2O2 treated ROC was beneficial for DOC removal, but markedly inhibited the activities of the nitrifying bacteria (i.e., nitrite oxidising bacteria) in the BAC system and hence compromised total nitrogen removal. This work demonstrated that the BAC treatment could be acclimated to the very high salinity environment, and could be used as a robust method for the removal of organic matter and nitrogen from the pre-oxidised ROC under optimised conditions.
Collapse
|
50
|
Ochando Pulido JM, Martínez Férez A. Impacts of operating conditions on nanofiltration of secondary-treated two-phase olive mill wastewater. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2015; 161:219-227. [PMID: 26186549 DOI: 10.1016/j.jenvman.2015.07.014] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/14/2015] [Revised: 07/02/2015] [Accepted: 07/04/2015] [Indexed: 06/04/2023]
Abstract
In the present paper, a thin-film composite polymeric nanofiltration (NF) membrane is examined for the tertiary treatment of secondary-treated two-phase olive mill wastewater, in substitution of the reverse osmosis membrane used in previous work by the Authors. Overcoming the deleterious fouling phenomena persistently encountered in membrane processes managing wastewater streams was indeed pursued. Setting the adequate parameters of the operating variables - that is, operating at ambient temperature upon a net pressure equal to 13 bar (Pc), tangential crossflow in the order of 2.55 m s(-1) to attain enough turbulence over the membrane, and above the point of zero charge (pH > 5.8) of the membrane - ensured high steady-state permeate productivity (59.6 L h(-1) m(-2)), also economically sustainable in time owed to minimization of the fouling-build up rate (0.91 h(-1)). Moreover, these conditions also provided high feed recovery (90%) and significant rejection efficiencies for the electroconductivity (58.1%) and organic matter (76.1%). This led to a purified permeate stream exiting the NF membrane operation exhibiting average EC and COD values equal to 1.4 mS cm(-1) and 45 mg L(-1). This permits complying with the water quality parameters established by different regulations for discharge public waterways and irrigation purposes.
Collapse
|