201
|
Abstract
Closed-loop (artificial pancreas) systems for automated insulin delivery have been likened to the holy grail of diabetes management. The first iterations of glucose-responsive insulin delivery were pioneered in the 1960s and 1970s, with the development of systems that used venous glucose measurements to dictate intravenous infusions of insulin and dextrose in order to maintain normoglycemia. Only recently have these bulky, bedside technologies progressed to miniaturized, wearable devices. These modern closed-loop systems use interstitial glucose sensing, subcutaneous insulin pumps, and increasingly sophisticated algorithms. As the number of commercially available hybrid closed-loop systems has grown, so too has the evidence supporting their efficacy. Future challenges in closed-loop technology include the development of fully closed-loop systems that do not require user input for meal announcements or carbohydrate counting. Another evolving avenue in research is the addition of glucagon to mitigate the risk of hypoglycemia and allow more aggressive insulin dosing.
Collapse
|
202
|
Garcia L, Kerns G, O'Reilley K, Okesanjo O, Lozano J, Narendran J, Broeking C, Ma X, Thompson H, Njapa Njeuha P, Sikligar D, Brockstein R, Golecki HM. The Role of Soft Robotic Micromachines in the Future of Medical Devices and Personalized Medicine. Micromachines 2021; 13:28. [PMID: 35056193 PMCID: PMC8781893 DOI: 10.3390/mi13010028] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 11/24/2021] [Accepted: 12/02/2021] [Indexed: 12/16/2022]
Abstract
Developments in medical device design result in advances in wearable technologies, minimally invasive surgical techniques, and patient-specific approaches to medicine. In this review, we analyze the trajectory of biomedical and engineering approaches to soft robotics for healthcare applications. We review current literature across spatial scales and biocompatibility, focusing on engineering done at the biotic-abiotic interface. From traditional techniques for robot design to advances in tunable material chemistry, we look broadly at the field for opportunities to advance healthcare solutions in the future. We present an extracellular matrix-based robotic actuator and propose how biomaterials and proteins may influence the future of medical device design.
Collapse
Affiliation(s)
- Lourdes Garcia
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Genevieve Kerns
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Kaitlin O'Reilley
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Omolola Okesanjo
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Jacob Lozano
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Jairaj Narendran
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Conor Broeking
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Xiaoxiao Ma
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Hannah Thompson
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Preston Njapa Njeuha
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Drashti Sikligar
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Reed Brockstein
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| | - Holly M Golecki
- Department of Bioengineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, USA
| |
Collapse
|
203
|
Dimitri P, Pignataro V, Lupo M, Bonifazi D, Henke M, Musazzi UM, Ernst F, Minghetti P, Redaelli DF, Antimisiaris SG, Migliaccio G, Bonifazi F, Marciani L, Courtenay AJ, Denora N, Lopedota A. Medical Device Development for Children and Young People-Reviewing the Challenges and Opportunities. Pharmaceutics 2021; 13:pharmaceutics13122178. [PMID: 34959459 PMCID: PMC8706877 DOI: 10.3390/pharmaceutics13122178] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 11/25/2021] [Accepted: 12/02/2021] [Indexed: 02/07/2023] Open
Abstract
Development of specific medical devices (MDs) is required to meet the healthcare needs of children and young people (CYP). In this context, MD development should address changes in growth and psychosocial maturation, physiology, and pathophysiology, and avoid inappropriate repurposing of adult technologies. Underpinning the development of MD for CYP is the need to ensure MD safety and effectiveness through pediatric MD-specific regulations. Contrary to current perceptions of limited market potential, the global pediatric healthcare market is expected to generate around USD 15,984 million by 2025. There are 1.8 billion young people in the world today; 40% of the global population is under 24, creating significant future healthcare market opportunities. This review highlights a number of technology areas that have led to successful pediatric MD, including 3D printing, advanced materials, drug delivery, and diagnostic imaging. To ensure the targeted development of MD for CYP, collaboration across multiple professional disciplines is required, facilitated by a platform to foster collaboration and drive innovation. The European Pediatric Translational Research Infrastructure (EPTRI) will be established as the European platform to support collaboration, including the life sciences industrial sector, to identify unmet needs in child health and support the development, adoption, and commercialization of pediatric MDs.
Collapse
Affiliation(s)
- Paul Dimitri
- Department of Pediatric Endocrinology, Sheffield Children’s NHS Foundation Trust & Sheffield Hallam University, Shefeld S10 2TH, UK;
| | - Valeria Pignataro
- Consorzio per Valutazioni Biologiche e Farmacologiche, Via N. Putignani 178, 70122 Bari, Italy; (V.P.); (D.B.); (G.M.)
| | - Mariangela Lupo
- TEDDY European Network of Excellence for Paediatric Research, Via Luigi Porta 14, 27100 Pavia, Italy;
| | - Donato Bonifazi
- Consorzio per Valutazioni Biologiche e Farmacologiche, Via N. Putignani 178, 70122 Bari, Italy; (V.P.); (D.B.); (G.M.)
| | - Maria Henke
- Institute for Robotics and Cognitive Systems, University of Luebeck, Ratzeburger Allee 160, 23562 Luebeck, Germany; (M.H.); (F.E.)
| | - Umberto M. Musazzi
- Department of Pharmaceutical Sciences, Università degli Studi di Milano, Via G. Colombo, 20133 Milan, Italy; (U.M.M.); (P.M.)
| | - Floris Ernst
- Institute for Robotics and Cognitive Systems, University of Luebeck, Ratzeburger Allee 160, 23562 Luebeck, Germany; (M.H.); (F.E.)
| | - Paola Minghetti
- Department of Pharmaceutical Sciences, Università degli Studi di Milano, Via G. Colombo, 20133 Milan, Italy; (U.M.M.); (P.M.)
| | - Davide F. Redaelli
- Scientific Institute IRCCS E. Medea, Bosisio Parini, 23843 Lecco, Italy;
| | | | - Giovanni Migliaccio
- Consorzio per Valutazioni Biologiche e Farmacologiche, Via N. Putignani 178, 70122 Bari, Italy; (V.P.); (D.B.); (G.M.)
| | - Fedele Bonifazi
- Fondazione per la ricerca farmacologica Gianni Benzionlus, Via Abate Eustasio, 30, 70010 Valenzano, Italy;
| | - Luca Marciani
- Translational Medical Sciences, National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and University of Nottingham, Derby Road, Nottingham NG7 2UH, UK;
| | - Aaron J. Courtenay
- School of Pharmacy and Pharmaceutical Sciences, Coleraine Campus, Ulster University, Cromore Road, Coleraine, Co. Londonderry, Northern Ireland BT52 1SA, UK;
| | - Nunzio Denora
- Department of Pharmacy-Pharmaceutical Sciences, University of Bari Aldo Moro, Via E. Orabona 4, 70125 Bari, Italy
- Correspondence: (N.D.); (A.L.)
| | - Angela Lopedota
- Department of Pharmacy-Pharmaceutical Sciences, University of Bari Aldo Moro, Via E. Orabona 4, 70125 Bari, Italy
- Correspondence: (N.D.); (A.L.)
| |
Collapse
|
204
|
Koldeweij C, Clarke J, Nijman J, Feather C, de Wildt SN, Appelbaum N. CE Accreditation and Barriers to CE Marking of Pediatric Drug Calculators for Mobile Devices: Scoping Review and Qualitative Analysis. J Med Internet Res 2021; 23:e31333. [PMID: 34898456 PMCID: PMC8713103 DOI: 10.2196/31333] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Revised: 11/01/2021] [Accepted: 11/02/2021] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Pediatric drug calculators (PDCs) intended for clinical use qualify as medical devices under the Medical Device Directive and the Medical Device Regulation. The extent to which they comply with European standards on quality and safety is unknown. OBJECTIVE This study determines the number of PDCs available as mobile apps for use in the Netherlands that bear a CE mark, and explore the factors influencing the CE marking of such devices among app developers. METHODS A scoping review of Google Play Store and Apple App Store was conducted to identify PDCs available for download in the Netherlands. CE accreditation of the sampled apps was determined by consulting the app landing pages on app stores, by screening the United Kingdom Medicines and Healthcare products Regulatory Agency's online registry of medical devices, and by surveying app developers. The barriers to CE accreditation were also explored through a survey of app developers. RESULTS Of 632 screened apps, 74 were eligible, including 60 pediatric drug dosage calculators and 14 infusion rate calculators. One app was CE marked. Of the 20 (34%) respondents to the survey, 8 considered their apps not to be medical devices based on their intent of use or functionality. Three developers had not aimed to make their app available for use in Europe. Other barriers that may explain the limited CE accreditation of sampled PDC apps included poor awareness of European regulations among developers and a lack of restrictions when placing PDCs in app stores. CONCLUSIONS The compliance of PDCs with European standards on medical devices is poor. This puts clinicians and their patients at risk of medical errors resulting from the largely unrestricted use of these apps.
Collapse
Affiliation(s)
- Charlotte Koldeweij
- Institute of Global Health Innovation, Imperial College London, London, United Kingdom.,Department of Pharmacology and Toxicology, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, Netherlands
| | - Jonathan Clarke
- Centre for Mathematics of Precision Healthcare, Imperial College London, London, United Kingdom
| | - Joppe Nijman
- Department of Pediatric Intensive Care, University Medical Centre Utrecht, Utrecht, Netherlands
| | - Calandra Feather
- Institute of Global Health Innovation, Imperial College London, London, United Kingdom
| | - Saskia N de Wildt
- Department of Pharmacology and Toxicology, Radboud Institute for Health Sciences, Radboud University Medical Center, Nijmegen, Netherlands.,Intensive Care and Department of Intensive Care, Erasmus MC Sophia Children's Hospital, Rotterdam, Netherlands
| | - Nicholas Appelbaum
- Institute of Global Health Innovation, Imperial College London, London, United Kingdom
| |
Collapse
|
205
|
Panetta D, Tollapi L, Paolicchi A, Marri E, Aringhieri G, Caramella D. Comparative structural analysis of polyurethane and silicone catheters of totally implantable venous access devices by micro-computed tomography. SAGE Open Med 2021; 9:20503121211059949. [PMID: 34881041 PMCID: PMC8646823 DOI: 10.1177/20503121211059949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2021] [Accepted: 10/27/2021] [Indexed: 11/15/2022] Open
Abstract
Objectives: To investigate microstructural alterations of explanted long-term central venous catheters of totally implantable venous access devices, using micro-computed tomography. Methods: A total of 16 catheters (9 made of silicone and 7 made of polyurethane), all non-fractured, have been analyzed in this study. Eight catheters were implanted for an average duration of 994 days (min–max: 98–2731 days), while the remaining eight catheters (four for each material, forming the SIref and PUref control groups) were analyzed before implant and used as a reference. X-ray micro-computed tomography was used to reconstruct the three-dimensional geometry of selected segments of each catheter (ca. 10 cm per sample). Results: Morphometric analysis of the catheters revealed increases wall thickness and section area in the polyurethane group as compared with the reference central venous catheters of the same materials (wall thickness: 403 ± 12 μm in the polyurethane (PU) group vs 382 ± 4 μm in PUref, p = 0.014; wall cross-section area: 2.04 ± 0.09 mm2 in PU vs 1.91 ± 0.03 mm2 in PUref, p = 0.04), whereas implanted silicone catheters showed a larger luminal cross section as compared with their controls (lumen cross-section area = 0.851 ± 0.020 mm2 in silicone (SI) group vs 0.811 ± 0.007 mm2 in SIref, p = 0.007). All analyzed samples in this study presented some type of alteration in the catheter walls, namely, hyperdense spots (below 0.1 mm size), air gaps/bubbles and displacements of inner and outer axes causing heterogeneous wall thickness. The incidence of air gaps showed no difference with respect to both material type and duration of implant, whereas the SI group revealed more hyperdense spots as compared to all other groups. Conclusion: Morphological change and local structural alteration can occur in both silicone and polyurethane catheters. This evidence suggests the need for further studies connecting those morphological changes with modification of mechanical robustness, which ultimately can play a role for patient safety.
Collapse
Affiliation(s)
| | - Lara Tollapi
- Anesthesiology and Pain Therapy Unit - Vascular Access Team, University Hospital of Pisa, Pisa, Italy
| | - Adriana Paolicchi
- Anesthesiology and Pain Therapy Unit - Vascular Access Team, University Hospital of Pisa, Pisa, Italy
| | - Elisa Marri
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Giacomo Aringhieri
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| | - Davide Caramella
- Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Pisa, Italy
| |
Collapse
|
206
|
Delavoipière E, Bouglé C, Saint-Lorant G, Divanon F, Alix A. [Quality Management Of The Experimental Health Products Circuit In Hospital Pharmacies: National Inventory And Proposed Standardised Tools]. Ann Pharm Fr 2021; 80:758-768. [PMID: 34896379 DOI: 10.1016/j.pharma.2021.11.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 11/11/2021] [Accepted: 11/29/2021] [Indexed: 11/18/2022]
Abstract
OBJECTIVES Carry out a national inventory of the current situation regarding the quality management of the investigational health products circuit, to develop adapted standardised tools. METHODS A survey of 76 questions, developed by a regional working group, was conducted among clinical research pharmacists in French facilities. Tools were developed to meet the identified needs and validated by participating pharmacists, using the Delphi method. The consensus was defined by achieving a score above 80% on relevance, clarity and evaluability. RESULTS Among 94 pharmacists participating in the survey, 88 were interested in standardised tools. The score for the implementation of a quality approach depended on the type of health facility (p<0.0005) and increased with the number of active trials (p<0.0005). All nine proposed tools were useful for over two thirds of pharmacists, but the self-assessment and audit grids have been prioritised. Indeed, only 26% of pharmacies carried out a prior risk assessment and 14% carried out internal audits. The review of both grids led to a consensus on 89% and 97% of the criteria respectively. The validated grids include 62 and 72 criteria respectively. DISCUSSION The quality approach of the investigational health products circuit is heterogeneous in the participating centres, with a strong need for standardised tools. The two grids are relevant tools developed by and for professionals. CONCLUSION The tools developed will enable to optimise the quality approach by identifying the non-conformities of the investigational health products circuit.
Collapse
Affiliation(s)
- E Delavoipière
- Service de pharmacie, centre de lutte contre le cancer François-Baclesse, 3, avenue Général-Harris, BP 45026, 14076 Caen cedex 5, France.
| | - C Bouglé
- Observatoire du médicament, des dispositifs médicaux et des innovations thérapeutiques de Normandie, espace Claude-Monet Basse-Normandie, 2, place Jean-Nouzille, 14000 Caen, France
| | - G Saint-Lorant
- Service de pharmacie, CHU de Caen, avenue de la Côte-de-Nacre, 14033 Caen cedex 9, France
| | - F Divanon
- Service de pharmacie, centre de lutte contre le cancer François-Baclesse, 3, avenue Général-Harris, BP 45026, 14076 Caen cedex 5, France
| | - A Alix
- Service de pharmacie, CHU de Caen, avenue de la Côte-de-Nacre, 14033 Caen cedex 9, France
| |
Collapse
|
207
|
Zamzam AH, Al-Ani AKI, Wahab AKA, Lai KW, Satapathy SC, Khalil A, Azizan MM, Hasikin K. Prioritisation Assessment and Robust Predictive System for Medical Equipment: A Comprehensive Strategic Maintenance Management. Front Public Health 2021; 9:782203. [PMID: 34869194 PMCID: PMC8637834 DOI: 10.3389/fpubh.2021.782203] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Accepted: 10/25/2021] [Indexed: 01/25/2023] Open
Abstract
The advancement of technology in medical equipment has significantly improved healthcare services. However, failures in upkeeping reliability, availability, and safety affect the healthcare services quality and significant impact can be observed in operations' expenses. The effective and comprehensive medical equipment assessment and monitoring throughout the maintenance phase of the asset life cycle can enhance the equipment reliability, availability, and safety. The study aims to develop the prioritisation assessment and predictive systems that measure the priority of medical equipment's preventive maintenance, corrective maintenance, and replacement programmes. The proposed predictive model is constructed by analysing features of 13,352 medical equipment used in public healthcare clinics in Malaysia. The proposed system comprises three stages: prioritisation analysis, model training, and predictive model development. In this study, we proposed 16 combinations of novel features to be used for prioritisation assessment and prediction of preventive maintenance, corrective maintenance, and replacement programme. The modified k-Means algorithm is proposed during the prioritisation analysis to automatically distinguish raw data into three main clusters of prioritisation assessment. Subsequently, these clusters are fed into and tested with six machine learning algorithms for the predictive prioritisation system. The best predictive models for medical equipment's preventive maintenance, corrective maintenance, and replacement programmes are selected among the tested machine learning algorithms. Findings indicate that the Support Vector Machine performs the best in preventive maintenance and replacement programme prioritisation predictive systems with the highest accuracy of 99.42 and 99.80%, respectively. Meanwhile, K-Nearest Neighbour yielded the highest accuracy in corrective maintenance prioritisation predictive systems with 98.93%. Based on the promising results, clinical engineers and healthcare providers can widely adopt the proposed prioritisation assessment and predictive systems in managing expenses, reporting, scheduling, materials, and workforce.
Collapse
Affiliation(s)
- Aizat Hilmi Zamzam
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia.,Engineering Services Department, Ministry of Health Malaysia, Putrajaya, Malaysia
| | | | - Ahmad Khairi Abdul Wahab
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Khin Wee Lai
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Suresh Chandra Satapathy
- School of Computer Engineering, Kalinga Institute of Industrial Technology, Deemed to Be University, Bhubaneswar, India
| | - Azira Khalil
- Faculty of Science and Technology, Universiti Sains Islam Malaysia, Nilai, Malaysia
| | - Muhammad Mokhzaini Azizan
- Department of Electrical and Electronic Engineering, Faculty of Engineering and Built Environment, Universiti Sains Islam Malaysia, Nilai, Malaysia
| | - Khairunnisa Hasikin
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
208
|
Timbie JW, Kim AY, Concannon TW. Use of Real-World Evidence for Regulatory Approval and Coverage of Medical Devices: A Landscape Assessment. Value Health 2021; 24:1792-1798. [PMID: 34838277 DOI: 10.1016/j.jval.2021.07.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 06/23/2021] [Accepted: 07/10/2021] [Indexed: 06/13/2023]
Abstract
OBJECTIVES To enhance the generalizability of the evidence it reviews, the US Food and Drug Administration (FDA) has encouraged manufacturers to expand the submission of real-world evidence (RWE). The extent to which this evidence, which is generated outside of research settings, can support decision making remains unclear. We described the current use of RWE for medical devices, assessed manufacturers' challenges in generating and using it for regulatory and coverage decisions, and identified opportunities to expand its use. METHODS We conducted 27 solo and group interviews with FDA officials and representatives of device manufacturers, payers, and health technology assessment organizations. All interviews used a semistructured protocol and were transcribed to allow thematic analysis. RESULTS Accessing and linking real-world data sources, identifying unique devices, capturing longitudinal data, limited staff expertise, and uncertain return on investment have hampered efforts to use real-world data. Many companies in our sample were conducting research using real-world data, but none had submitted RWE as the primary evidence supporting a premarket approval. FDA guidance was helpful, but regulatory requirements remained ambiguous and examples of successful regulatory decisions based on RWE were limited. Payers mainly used RWE to supplement experimental evidence in coverage decisions, evaluated both types of evidence in similar ways, and had concerns about the rigor of RWE. CONCLUSIONS Technical challenges may slow efforts to generate and use RWE in the near term. Additional regulatory guidance and examples, greater use of rigorous study designs and analytic methods, and continued stakeholder engagement could accelerate the use of RWE.
Collapse
|
209
|
Sharman JE, Kosmala W. High-quality medical research requires that equipment has been validated for accuracy. ADV CLIN EXP MED 2021; 30:1221-1223. [PMID: 34898059 DOI: 10.17219/acem/144440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
It is not always appreciated that medical equipment may be cleared by regulatory authorities to sell within a country, without ever having been tested for accuracy performance according to scientific validation standards. Instead, manufacturers can undertake in-house accuracy testing, using variable methods and without any requirement for test results to be made publicly available. This lack of full transparency together with potential for industry bias can place doubt over the quality of validation results provided to regulatory authorities. Currently, this situation affects the field of hypertension research, where most blood pressure devices have not been independently validated for accuracy according to international scientific standards, nor as expected in clinical practice guidelines. More attention should be paid to such practices in order to improve the quality of research and to optimize further translation of scientific findings to clinical practice. The clinical implications of inaccurate measurements in research can be far-reaching, ultimately impacting on a patient's health. Well-planned validating studies should be more widely considered for new devices that are candidates to be used in research protocols. The awareness of the lack or uncertain validation of equipment used for verifying research hypotheses should prompt all investigators to revisit the idea of conducting the study or, at least, to acknowledge this issue as a relevant study limitation. One of the ways in which authors submitting research findings for publication can add to the quality of the reporting of their work is to ensure reference to the accuracy validation of their research equipment.
Collapse
Affiliation(s)
- James E Sharman
- Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia
| | - Wojciech Kosmala
- Department of Cardiovascular Imaging, Institute of Heart Diseases, Wroclaw Medical University, Poland
| |
Collapse
|
210
|
Lian H, Chen H, Han Q. [Spermic Toxicity Test of Medical Devices for Human Assisted Reproductive Technology]. Zhongguo Yi Liao Qi Xie Za Zhi 2021; 45:608-611. [PMID: 34862771 DOI: 10.3969/j.issn.1671-7104.2021.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
In order to provide a thorough summary and analysis over sperm toxicity evaluation of medical devices for human in vitro assisted reproductive technology, as well as to forecast its future direction, currently available test methods and evaluation indicators related to human sperm were elaborated here. Furthermore, their weakness and risk points were analyzed and possible ways for further improvement were also provided.
Collapse
Affiliation(s)
- Huan Lian
- National Institutes for Food and Drug Control, Beijing, 102629
| | - Hong Chen
- National Institutes for Food and Drug Control, Beijing, 102629
| | - Qianqian Han
- National Institutes for Food and Drug Control, Beijing, 102629
| |
Collapse
|
211
|
Vomero M, Schiavone G. Biomedical Microtechnologies Beyond Scholarly Impact. Micromachines (Basel) 2021; 12:mi12121471. [PMID: 34945320 PMCID: PMC8709221 DOI: 10.3390/mi12121471] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Revised: 11/22/2021] [Accepted: 11/24/2021] [Indexed: 11/16/2022]
Abstract
The recent tremendous advances in medical technology at the level of academic research have set high expectations for the clinical outcomes they promise to deliver. To the demise of patient hopes, however, the more disruptive and invasive a new technology is, the bigger the gap is separating the conceptualization of a medical device and its adoption into healthcare systems. When technology breakthroughs are reported in the biomedical scientific literature, news focus typically lies on medical implications rather than engineering progress, as the former are of higher appeal to a general readership. While successful therapy and diagnostics are indeed the ultimate goals, it is of equal importance to expose the engineering thinking needed to achieve such results and, critically, identify the challenges that still lie ahead. Here, we would like to provoke thoughts on the following questions, with particular focus on microfabricated medical devices: should research advancing the maturity and reliability of medical technology benefit from higher accessibility and visibility? How can the scientific community encourage and reward academic work on the overshadowed engineering aspects that will facilitate the evolution of laboratory samples into clinical devices?
Collapse
Affiliation(s)
- Maria Vomero
- BioEE Laboratory, Electrical Engineering Department, Columbia University, New York, NY 10027, USA;
| | - Giuseppe Schiavone
- Research Management & Innovation Directorate, King’s College London, Tower Wing, Guy’s Hospital, London SE1 9RT, UK
- Correspondence:
| |
Collapse
|
212
|
Giansanti D, Gulino RA. The Cybersecurity and the Care Robots: A Viewpoint on the Open Problems and the Perspectives. Healthcare (Basel) 2021; 9:healthcare9121653. [PMID: 34946379 PMCID: PMC8702125 DOI: 10.3390/healthcare9121653] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 11/23/2021] [Accepted: 11/24/2021] [Indexed: 11/16/2022] Open
Abstract
Care robots represent an opportunity for the health domain. The use of these robots has important implications. They can be used in surgery, rehabilitation, assistance, therapy, and other medical fields. Therefore, care robots (CR)s, have both important physical and psychological implications during their use. Furthermore, these devices, meet important data in clinical applications. These data must be protected. Therefore, cybersecurity (CS) has become a crucial characteristic that concerns all the involved actors. The study investigated the collocation of CRs in the context of CS studies in the health domain. Problems and peculiarities of these devices, with reference to the CS, were faced, investigating in different scientific databases. Highlights, ranging also from ethics implications up to the regulatory legal framework (ensuring safety and cybersecurity) have been reported. Models and cyber-attacks applicable on the CRs have been identified.
Collapse
Affiliation(s)
- Daniele Giansanti
- Centre Tisp, Istituto Superiore di Sanità, 00161 Rome, Italy
- Correspondence: ; Tel.: +39-06-49902701
| | - Rosario Alfio Gulino
- Faculty of Engineering, Tor Vergata University, Via Cracovia, 00133 Roma, Italy;
| |
Collapse
|
213
|
Bueno-López C, Tamarit-Martínez C, Alambiaga-Caravaca AM, Balaguer-Fernández C, Merino V, López-Castellano A, Rodilla V. 3D Printing of Temporary Prostheses for Controlled-Release of Drugs: Design, Physical Characterization and Preliminary Studies. Pharmaceuticals (Basel) 2021; 14:ph14121240. [PMID: 34959642 PMCID: PMC8708214 DOI: 10.3390/ph14121240] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 11/15/2021] [Accepted: 11/26/2021] [Indexed: 11/16/2022] Open
Abstract
In recent years, the use of 3D printing technologies in orthopedic surgery has markedly increased, as they offer the possibility of printing personalized prostheses. The work presented in this article is a preliminary study of a research project which aims to manufacture customized spacers containing antibiotics for use in joint replacement surgery. The objective of this work was to design and print different 3D constructs to evaluate the use of different materials, their properties after the process of 3D printing, such as resistance, and the release kinetics of drugs from the constructs. Different designs and different materials were analyzed to obtain a 3D construct with suitable properties. Our design takes advantage of the micropores created between the layers of the 3D printed filaments to release the contained drug. Using polylactic acid (PLA) we were able to print cylindrical structures with interconnected micropores and a hollow chamber capable of releasing methylene blue, which was selected as a model drug. The final PLA 3D construct was printed with a 10% infill. The physical and technological characteristics, morphological changes at body temperature and interaction with water were considered to be acceptable. The PLA 3D printed constructs were found to have sufficient strength to withstand a force of 500 kg. The results obtained allow to continue research in this project, with the aim of manufacturing prostheses containing a reservoir of antibiotics or other drugs in their interior for their subsequent controlled release.
Collapse
Affiliation(s)
- Carlos Bueno-López
- Instituto de Ciencias Biomédicas, Departamento de Farmacia, Facultad de Ciencias de la Salud, Universidad Cardenal Herrera-CEU, CEU Universities, C/Santiago Ramón y Cajal s/n, 46115 Valencia, Spain; (C.B.-L.); (C.T.-M.); (A.M.A.-C.); (C.B.-F.)
| | - Carlos Tamarit-Martínez
- Instituto de Ciencias Biomédicas, Departamento de Farmacia, Facultad de Ciencias de la Salud, Universidad Cardenal Herrera-CEU, CEU Universities, C/Santiago Ramón y Cajal s/n, 46115 Valencia, Spain; (C.B.-L.); (C.T.-M.); (A.M.A.-C.); (C.B.-F.)
| | - Adrián M. Alambiaga-Caravaca
- Instituto de Ciencias Biomédicas, Departamento de Farmacia, Facultad de Ciencias de la Salud, Universidad Cardenal Herrera-CEU, CEU Universities, C/Santiago Ramón y Cajal s/n, 46115 Valencia, Spain; (C.B.-L.); (C.T.-M.); (A.M.A.-C.); (C.B.-F.)
| | - Cristina Balaguer-Fernández
- Instituto de Ciencias Biomédicas, Departamento de Farmacia, Facultad de Ciencias de la Salud, Universidad Cardenal Herrera-CEU, CEU Universities, C/Santiago Ramón y Cajal s/n, 46115 Valencia, Spain; (C.B.-L.); (C.T.-M.); (A.M.A.-C.); (C.B.-F.)
| | - Virginia Merino
- Departamento de Farmacia y Tecnología Farmacéutica y Parasitología, Facultad de Farmacia, Universitat de València, Av. Vicente Andrés Estellés s/n, 46100 Valencia, Spain;
- Instituto Interuniversitario de Investigación de Reconocimiento Molecular y Desarrollo Tecnológico (IDM), Universitat Politècnica de València, Universitat de València, 46005 Valencia, Spain
| | - Alicia López-Castellano
- Instituto de Ciencias Biomédicas, Departamento de Farmacia, Facultad de Ciencias de la Salud, Universidad Cardenal Herrera-CEU, CEU Universities, C/Santiago Ramón y Cajal s/n, 46115 Valencia, Spain; (C.B.-L.); (C.T.-M.); (A.M.A.-C.); (C.B.-F.)
- Correspondence: (A.L.-C.); (V.R.); Tel.: +34-961-369-000 (ext. 64527) (V.R.)
| | - Vicent Rodilla
- Instituto de Ciencias Biomédicas, Departamento de Farmacia, Facultad de Ciencias de la Salud, Universidad Cardenal Herrera-CEU, CEU Universities, C/Santiago Ramón y Cajal s/n, 46115 Valencia, Spain; (C.B.-L.); (C.T.-M.); (A.M.A.-C.); (C.B.-F.)
- Correspondence: (A.L.-C.); (V.R.); Tel.: +34-961-369-000 (ext. 64527) (V.R.)
| |
Collapse
|
214
|
Lange J, Schneider A, Jordi C, Lau M, Disher T. Formative Study on the Wearability and Usability of a Large-Volume Patch Injector. Med Devices (Auckl) 2021; 14:363-377. [PMID: 34815721 PMCID: PMC8605886 DOI: 10.2147/mder.s337670] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2021] [Accepted: 11/03/2021] [Indexed: 11/23/2022] Open
Abstract
Background The subcutaneous self-administration of biologics using a single large-volume bolus dose requires novel large-volume patch injectors. However, the usability and wearability of such on-body devices has rarely been investigated thus far. Therefore, this formative simulated use experiment studies the overall handling and acceptability in terms of the size and weight of a novel 10 mL large-volume patch injector device platform. Methods Twenty-three participants, including patients and healthcare professionals, simulated two injections with the large-volume patch injector, each lasting 17 min. During the injections, the patient participants performed predefined movements and activities with the on-body devices. Perceived usability and wearability were assessed through observation by the moderator and participant-reported feedback using five-point Likert scales and open-ended interviews. Results All participants successfully completed the simulated injections. Only non-serious usability issues were identified. Users rated the device acceptability in terms of wearability and usability with high ratings. Conclusion The results suggest the safe and effective usage of a novel prefilled large-volume patch injector that enables the subcutaneous delivery of a single bolus dose of up to 10 mL with an injection duration of 15 min. The participants of the simulated use study successfully used the device regardless of the disease state, age, or body size and habitus.
Collapse
Affiliation(s)
- Jakob Lange
- Ypsomed Delivery Systems, Ypsomed AG, Burgdorf, Switzerland
| | | | | | - Michael Lau
- Insight Product Development, Chicago, IL, USA
| | | |
Collapse
|
215
|
Maccioni G, Ruscitto S, Gulino RA, Giansanti D. Opportunities and Problems of the Consensus Conferences in the Care Robotics. Healthcare (Basel) 2021; 9:1624. [PMID: 34946350 DOI: 10.3390/healthcare9121624] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 11/17/2021] [Accepted: 11/20/2021] [Indexed: 02/02/2023] Open
Abstract
Care robots represent an opportunity for the health domain. The use of these devices has important implications. They can be used in surgical operating rooms in important and delicate clinical interventions, in motion, in training-and-simulation, and cognitive and rehabilitation processes. They are involved in continuous processes of evolution in technology and clinical practice. Therefore, the introduction into routine clinical practice is difficult because this needs the stability and the standardization of processes. The agreement tools, in this case, are of primary importance for the clinical acceptance and introduction. The opinion focuses on the Consensus Conference tool and: (a) highlights its potential in the field; (b) explores the state of use; (c) detects the peculiarities and problems (d) expresses ideas on how improve its diffusion.
Collapse
|
216
|
Dendooven E, Foubert K, Naessens T, Pieters L, Lambert J, Goossens A, Aerts O. Allergic contact dermatitis from ("hypoallergenic") adhesives containing D-limonene. Contact Dermatitis 2021; 86:113-119. [PMID: 34786729 DOI: 10.1111/cod.14008] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 11/11/2021] [Accepted: 11/13/2021] [Indexed: 11/28/2022]
Abstract
BACKGROUND Besides being a potential component of (some species of) colophonium, D-limonene is also used as a tackifier in the production of adhesives. Hydroperoxides of limonene are well-known skin sensitizers. OBJECTIVES To show that D-limonene may be present in colophonium-containing but also colophonium-free ("hypoallergenic") adhesives, and that patients suffering from allergic contact dermatitis (ACD) from both types of adhesives might display positive patch test reactions to limonene hydroperoxides in this regard. METHODS Five patients with suspected ACD from adhesives were patch tested to the baseline series (containing limonene hydroperoxides 0.3 and 0.2% pet.), additional series and, if available, to the culprit adhesives. The adhesives labelled as containing colophonium (n = 3) or free from it (n = 2) were analysed with gas chromatography - mass spectrometry (GC-MS) for the presence of D-limonene. RESULTS All five patients sensitised to adhesives had (strong) positive patch test reactions to limonene hydroperoxides. The presence of D-limonene, and/or related components, could be demonstrated in all three colophonium-containing and, surprisingly, also in two colophonium-free ("hypoallergenic") tapes. CONCLUSIONS D-limonene may be present in both regular and "hypoallergenic" adhesives, with limonene hydroperoxides potentially contributing to ACD from such medical devices. The use of fragrance chemicals in adhesives deserves further research.
Collapse
Affiliation(s)
- Ella Dendooven
- Department of Dermatology, University Hospital Antwerp (UZA) and Research group Immunology, INFLA-MED Centre of Excellence, University of Antwerp, Antwerp, Belgium.,Research Group Natural Products & Food - Research and Analysis (NatuRA), Department of Pharmaceutical Sciences, University of Antwerp, Antwerp, Belgium
| | - Kenn Foubert
- Research Group Natural Products & Food - Research and Analysis (NatuRA), Department of Pharmaceutical Sciences, University of Antwerp, Antwerp, Belgium
| | - Tania Naessens
- Research Group Natural Products & Food - Research and Analysis (NatuRA), Department of Pharmaceutical Sciences, University of Antwerp, Antwerp, Belgium
| | - Luc Pieters
- Research Group Natural Products & Food - Research and Analysis (NatuRA), Department of Pharmaceutical Sciences, University of Antwerp, Antwerp, Belgium
| | - Julien Lambert
- Department of Dermatology, University Hospital Antwerp (UZA) and Research group Immunology, INFLA-MED Centre of Excellence, University of Antwerp, Antwerp, Belgium
| | - An Goossens
- Department of Dermatology, University Hospitals K.U.Leuven, Leuven, Belgium
| | - Olivier Aerts
- Department of Dermatology, University Hospital Antwerp (UZA) and Research group Immunology, INFLA-MED Centre of Excellence, University of Antwerp, Antwerp, Belgium
| |
Collapse
|
217
|
Fraser AG, Nelissen RGHH, Kjærsgaard-Andersen P, Szymański P, Melvin T, Piscoi P. Improved clinical investigation and evaluation of high-risk medical devices: the rationale and objectives of CORE-MD (Coordinating Research and Evidence for Medical Devices). EFORT Open Rev 2021; 6:839-849. [PMID: 34760284 PMCID: PMC8559562 DOI: 10.1302/2058-5241.6.210081] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
Abstract
In the European Union (EU), the delivery of health services is a national responsibility but there are concerted actions between member states to protect public health. Approval of pharmaceutical products is the responsibility of the European Medicines Agency, while authorising the placing on the market of medical devices is decentralised to independent ‘conformity assessment’ organisations called notified bodies. The first legal basis for an EU system of evaluating medical devices and approving their market access was the Medical Device Directive, from the 1990s. Uncertainties about clinical evidence requirements, among other reasons, led to the EU Medical Device Regulation (2017/745) that has applied since May 2021. It provides general principles for clinical investigations but few methodological details – which challenges responsible authorities to set appropriate balances between regulation and innovation, pre- and post-market studies, and clinical trials and real-world evidence. Scientific experts should advise on methods and standards for assessing and approving new high-risk devices, and safety, efficacy, and transparency of evidence should be paramount. The European Commission recently awarded a Horizon 2020 grant to a consortium led by the European Society of Cardiology and the European Federation of National Associations of Orthopaedics and Traumatology, that will review methodologies of clinical investigations, advise on study designs, and develop recommendations for aggregating clinical data from registries and other real-world sources. The CORE–MD project (Coordinating Research and Evidence for Medical Devices) will run until March 2024. Here, we describe how it may contribute to the development of regulatory science in Europe. Cite this article: EFORT Open Rev 2021;6:839-849. DOI: 10.1302/2058-5241.6.210081
Collapse
Affiliation(s)
- Alan G Fraser
- Department of Cardiology, University Hospital of Wales, Cardiff, UK
| | - Rob G H H Nelissen
- Department of Orthopaedics, Leiden University Medical Center, Leiden, Netherlands
| | | | - Piotr Szymański
- Centre of Postgraduate Medical Education, MSWiA Central Clinical Hospital, Warsaw, Poland
| | - Tom Melvin
- Healthcare Products Regulatory Authority, Earlsfort Terrace, Dublin 2, Ireland
| | - Paul Piscoi
- Health Technology Unit B6, Directorate General for Health (DG SANTE), European Commission, Brussels, Belgium
| | | |
Collapse
|
218
|
Dadi NCT, Radochová B, Vargová J, Bujdáková H. Impact of Healthcare-Associated Infections Connected to Medical Devices-An Update. Microorganisms 2021; 9:2332. [PMID: 34835457 PMCID: PMC8618630 DOI: 10.3390/microorganisms9112332] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2021] [Revised: 11/06/2021] [Accepted: 11/08/2021] [Indexed: 01/12/2023] Open
Abstract
Healthcare-associated infections (HAIs) are caused by nosocomial pathogens. HAIs have an immense impact not only on developing countries but also on highly developed parts of world. They are predominantly device-associated infections that are caused by the planktonic form of microorganisms as well as those organized in biofilms. This review elucidates the impact of HAIs, focusing on device-associated infections such as central line-associated bloodstream infection including catheter infection, catheter-associated urinary tract infection, ventilator-associated pneumonia, and surgical site infections. The most relevant microorganisms are mentioned in terms of their frequency of infection on medical devices. Standard care bundles, conventional therapy, and novel approaches against device-associated infections are briefly mentioned as well. This review concisely summarizes relevant and up-to-date information on HAIs and HAI-associated microorganisms and also provides a description of several useful approaches for tackling HAIs.
Collapse
Affiliation(s)
| | - Barbora Radochová
- Department of Microbiology and Virology, Faculty of Natural Sciences, Comenius University in Bratislava, 84215 Bratislava, Slovakia; (N.C.T.D.); (J.V.)
| | | | - Helena Bujdáková
- Department of Microbiology and Virology, Faculty of Natural Sciences, Comenius University in Bratislava, 84215 Bratislava, Slovakia; (N.C.T.D.); (J.V.)
| |
Collapse
|
219
|
Kaplan B. Legal Matters: The Legal Context of Health Informatics in Global Pandemics. Stud Health Technol Inform 2021; 286:11-5. [PMID: 34755682 DOI: 10.3233/SHTI210627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register]
Abstract
Law and regulation have not received much attention as part of the context shaping and being shaped by health informatics. Telemedicine, data, devices and software, and electronic health records (EHRs) are examples of how technologies are affected by privacy, intellectual property protections, and other law and regulation.
Collapse
|
220
|
Grennan M, Kim GH, McConnell KJ, Swanson A. Hospital management practices and medical device costs. Health Serv Res 2021; 57:227-236. [PMID: 34731503 DOI: 10.1111/1475-6773.13898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Revised: 08/16/2021] [Accepted: 10/06/2021] [Indexed: 11/30/2022] Open
Abstract
OBJECTIVE To determine whether the variation in prices paid for cardiac medical devices was associated with management practices in cardiac units. STUDY SETTING Cardiac units in US hospitals. STUDY DESIGN We regressed unit prices on management practice scores and other hospital characteristics, with and without controls for device fixed effects, for the 11 top-spending cardiac device categories. DATA COLLECTION A trusted third party that had entered into a confidentiality agreement combined de-identified medical device price data for N = 213 US hospitals from ECRI's Supply Guide benchmarking service, with survey responses regarding management practices in those hospitals' cardiac units; the resulting merged data were made available to researchers for analysis with hospital identifiers removed. N = 1980 hospitals with interventional cardiac catheterization laboratories and at least 25 annual acute myocardial infarction discharges in 2010 were eligible for inclusion; N = 648 responded to the management practices survey; N = 213 subscribed to Supply Guide and purchased at least one of 11 top cardiac medical device categories. PRINCIPAL FINDINGS Cardiac units with better management practices paid lower prices for cardiac devices (percent decrease in price for one standard deviation increase in management score = 1.33%, 95% confidence interval 0.99-1.67). This was comparable in magnitude to the price decrease associated with a one standard deviation increase in patient volume. CONCLUSIONS Better management practices were associated with lower device prices. This relationship is robust, but modest in magnitude. This modest magnitude is similar, though, to other events expected to lower input prices, such as transparency in the form of benchmarking information and hospital mergers.
Collapse
Affiliation(s)
- Matthew Grennan
- Haas School, University of California, Berkeley, Berkeley, California, USA.,National Bureau of Economic Research, Cambridge, Massachusetts, USA
| | - Gi Heung Kim
- The Wharton School, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - K John McConnell
- Center for Health Systems Effectiveness and Department of Emergency Medicine, Oregon Health & Science University, Portland, Oregon, USA
| | - Ashley Swanson
- National Bureau of Economic Research, Cambridge, Massachusetts, USA.,Columbia Business School, Columbia University, New York, New York, USA
| |
Collapse
|
221
|
Sultana A, Zare M, Luo H, Ramakrishna S. Surface Engineering Strategies to Enhance the In Situ Performance of Medical Devices Including Atomic Scale Engineering. Int J Mol Sci 2021; 22:11788. [PMID: 34769219 PMCID: PMC8583812 DOI: 10.3390/ijms222111788] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 10/14/2021] [Accepted: 10/26/2021] [Indexed: 12/13/2022] Open
Abstract
Decades of intense scientific research investigations clearly suggest that only a subset of a large number of metals, ceramics, polymers, composites, and nanomaterials are suitable as biomaterials for a growing number of biomedical devices and biomedical uses. However, biomaterials are prone to microbial infection due to Escherichia coli (E. coli), Staphylococcus aureus (S. aureus), Staphylococcus epidermidis (S. epidermidis), hepatitis, tuberculosis, human immunodeficiency virus (HIV), and many more. Hence, a range of surface engineering strategies are devised in order to achieve desired biocompatibility and antimicrobial performance in situ. Surface engineering strategies are a group of techniques that alter or modify the surface properties of the material in order to obtain a product with desired functionalities. There are two categories of surface engineering methods: conventional surface engineering methods (such as coating, bioactive coating, plasma spray coating, hydrothermal, lithography, shot peening, and electrophoretic deposition) and emerging surface engineering methods (laser treatment, robot laser treatment, electrospinning, electrospray, additive manufacturing, and radio frequency magnetron sputtering technique). Atomic-scale engineering, such as chemical vapor deposition, atomic layer etching, plasma immersion ion deposition, and atomic layer deposition, is a subsection of emerging technology that has demonstrated improved control and flexibility at finer length scales than compared to the conventional methods. With the advancements in technologies and the demand for even better control of biomaterial surfaces, research efforts in recent years are aimed at the atomic scale and molecular scale while incorporating functional agents in order to elicit optimal in situ performance. The functional agents include synthetic materials (monolithic ZnO, quaternary ammonium salts, silver nano-clusters, titanium dioxide, and graphene) and natural materials (chitosan, totarol, botanical extracts, and nisin). This review highlights the various strategies of surface engineering of biomaterial including their functional mechanism, applications, and shortcomings. Additionally, this review article emphasizes atomic scale engineering of biomaterials for fabricating antimicrobial biomaterials and explores their challenges.
Collapse
Affiliation(s)
- Afreen Sultana
- Center for Nanotechnology & Sustainability, Department of Mechanical Engineering, National University of Singapore, Singapore 117581, Singapore; (A.S.); (S.R.)
| | - Mina Zare
- Center for Nanotechnology & Sustainability, Department of Mechanical Engineering, National University of Singapore, Singapore 117581, Singapore; (A.S.); (S.R.)
| | - Hongrong Luo
- Engineering Research Center in Biomaterials, Sichuan University, Chengdu 610064, China
| | - Seeram Ramakrishna
- Center for Nanotechnology & Sustainability, Department of Mechanical Engineering, National University of Singapore, Singapore 117581, Singapore; (A.S.); (S.R.)
| |
Collapse
|
222
|
Lilly CM, Ensom E, Teebagy S, DiMezza D, Dunlap D, Hafer N, Buchholz B, McManus D. Patient Preferences for Point-of-Care Testing: Survey Validation and Results. Point Care 2020; 19:112-5. [PMID: 34707464 DOI: 10.1097/poc.0000000000000214] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Background Studies of current opinion of our community members for the characteristics, mode, and location of use, use cases, and overall enthusiasm for point-of-care testing (POCT) diagnosis and management tools are needed. Study Design and Methods Qualitative research methods were used to develop, refine, and evaluate hardcopy and electronic versions of a 45-item English language survey. The accuracy of the instrument was measured by recorded structured interview, and its precision was measured by comparison to its administration to a group of uncompensated volunteers. Main Findings and Results Comparison of survey and structured interview data demonstrated high levels of accuracy. Highly concordant with significant levels of correlation and of direct association indicated favorable precision. Ninety-three percent of respondents believed that POCT could improve their care, and 56% identified having a POCT in their home as a top priority. Accuracy, insurance coverage, immediacy of results, and ease of use were identified as the most important characteristics of a POCT. Conclusions Community members strongly support the development of accurate, in-home devices that produce immediate results that can be used to diagnose, manage, and encourage their adherence to treatments for their medical conditions.
Collapse
|
223
|
Buonomo M, Ruggiero JL, Hylwa S. Titanium allergy as a likely cause of post-reconstruction dermatitis of the breast. Contact Dermatitis 2021; 86:142-143. [PMID: 34713461 DOI: 10.1111/cod.13997] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 10/25/2021] [Accepted: 10/26/2021] [Indexed: 11/28/2022]
Affiliation(s)
- Michele Buonomo
- Department of Dermatology, Park Nicollet Health Services, Minneapolis, Minnesota, USA.,University of Minnesota Medical School, Minneapolis, Minnesota, USA
| | - Jenna L Ruggiero
- Department of Dermatology, Park Nicollet Health Services, Minneapolis, Minnesota, USA.,University of Minnesota Medical School, Minneapolis, Minnesota, USA
| | - Sara Hylwa
- Department of Dermatology, Park Nicollet Health Services, Minneapolis, Minnesota, USA
| |
Collapse
|
224
|
Simeoni R, Colonnelli F, Eutizi V, Marchetti M, Paolini E, Papalini V, Punturo A, Salvò A, Scipinotti N, Serpente C, Barbini E, Troscia R, Maccioni G, Giansanti D. The Social Robot and the Digital Physiotherapist: Are We Ready for the Team Play? Healthcare (Basel) 2021; 9:1454. [PMID: 34828501 PMCID: PMC8618922 DOI: 10.3390/healthcare9111454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Revised: 10/20/2021] [Accepted: 10/23/2021] [Indexed: 11/17/2022] Open
Abstract
Motivation: We are witnessing two phenomena. The first is that the physiotherapist is increasingly becoming a figure that must interact with Digital Health. On the other hand, social robots through research are improving more and more in the aspects of social interaction thanks also to artificial intelligence and becoming useful in rehabilitation processes. It begins to become strategic to investigate the intersections between these two phenomena. Objective: Therefore, we set ourselves the goal of investigating the consensus and opinion of physiotherapists around the introduction of social robots in clinical practice both in rehabilitation and assistance. Procedure: An electronic survey has been developed focused on social robot-based rehabilitation and assistance and has been submitted to subjects focused on physiotherapy sciences to investigate their opinion and their level of consent regarding the use of the social robot in rehabilitation and assistance. Two samples of subjects were recruited: the first group (156 participating subjects, 79 males, 77 females, mean age 24.3 years) was in the training phase, and the second (167 participating subjects, 86 males, 81 females, mean age 42.4 years) group was involved in the work processes. An electronic feedback form was also submitted to investigate the acceptance of the proposed methodology. Results: The survey showed a consistency of the results between the two samples from which interesting considerations emerge. Contrary to stereotypes that report how AI-based devices put jobs at risk, physiotherapists are not afraid of these devices. The subjects involved in the study believe the following: (a) social robots can be reliable co-workers but will remain a complementary device; (b) their role will be of the utmost importance as an operational manager in their use and in performance monitoring; (c) these devices will allow an increase in working capacity and facilitate integration. All those involved in the study believe that the proposed electronic survey has proved to be a useful and effective tool that can be useful as a periodic monitoring tool and useful for scientific societies. Conclusions: The evolution of social robots represents an unstoppable process as does the increase in the aging of the population. Stakeholders must not look with suspicion toward these devices, which can represent an important resource, but rather invest in monitoring and consensus training initiatives.
Collapse
Affiliation(s)
- Rossella Simeoni
- Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, San Martino al Cimino, 01100 Viterbo, Italy; (R.S.); (F.C.); (V.E.); (M.M.); (E.P.); (V.P.); (A.P.); (A.S.); (N.S.); (C.S.); (E.B.); (R.T.)
| | - Federico Colonnelli
- Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, San Martino al Cimino, 01100 Viterbo, Italy; (R.S.); (F.C.); (V.E.); (M.M.); (E.P.); (V.P.); (A.P.); (A.S.); (N.S.); (C.S.); (E.B.); (R.T.)
| | - Veronica Eutizi
- Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, San Martino al Cimino, 01100 Viterbo, Italy; (R.S.); (F.C.); (V.E.); (M.M.); (E.P.); (V.P.); (A.P.); (A.S.); (N.S.); (C.S.); (E.B.); (R.T.)
| | - Matteo Marchetti
- Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, San Martino al Cimino, 01100 Viterbo, Italy; (R.S.); (F.C.); (V.E.); (M.M.); (E.P.); (V.P.); (A.P.); (A.S.); (N.S.); (C.S.); (E.B.); (R.T.)
| | - Elena Paolini
- Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, San Martino al Cimino, 01100 Viterbo, Italy; (R.S.); (F.C.); (V.E.); (M.M.); (E.P.); (V.P.); (A.P.); (A.S.); (N.S.); (C.S.); (E.B.); (R.T.)
| | - Valentina Papalini
- Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, San Martino al Cimino, 01100 Viterbo, Italy; (R.S.); (F.C.); (V.E.); (M.M.); (E.P.); (V.P.); (A.P.); (A.S.); (N.S.); (C.S.); (E.B.); (R.T.)
| | - Alessio Punturo
- Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, San Martino al Cimino, 01100 Viterbo, Italy; (R.S.); (F.C.); (V.E.); (M.M.); (E.P.); (V.P.); (A.P.); (A.S.); (N.S.); (C.S.); (E.B.); (R.T.)
| | - Alice Salvò
- Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, San Martino al Cimino, 01100 Viterbo, Italy; (R.S.); (F.C.); (V.E.); (M.M.); (E.P.); (V.P.); (A.P.); (A.S.); (N.S.); (C.S.); (E.B.); (R.T.)
| | - Nicoletta Scipinotti
- Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, San Martino al Cimino, 01100 Viterbo, Italy; (R.S.); (F.C.); (V.E.); (M.M.); (E.P.); (V.P.); (A.P.); (A.S.); (N.S.); (C.S.); (E.B.); (R.T.)
| | - Christian Serpente
- Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, San Martino al Cimino, 01100 Viterbo, Italy; (R.S.); (F.C.); (V.E.); (M.M.); (E.P.); (V.P.); (A.P.); (A.S.); (N.S.); (C.S.); (E.B.); (R.T.)
| | - Emanuele Barbini
- Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, San Martino al Cimino, 01100 Viterbo, Italy; (R.S.); (F.C.); (V.E.); (M.M.); (E.P.); (V.P.); (A.P.); (A.S.); (N.S.); (C.S.); (E.B.); (R.T.)
| | - Riccardo Troscia
- Faculty of Medicine and Surgery, Università Cattolica del Sacro Cuore, San Martino al Cimino, 01100 Viterbo, Italy; (R.S.); (F.C.); (V.E.); (M.M.); (E.P.); (V.P.); (A.P.); (A.S.); (N.S.); (C.S.); (E.B.); (R.T.)
| | | | | |
Collapse
|
225
|
Kucharczyk M, Słowik-Rylska M, Cyran-Stemplewska S, Gieroń M, Nowak-Starz G, Kręcisz B. Acrylates as a significant cause of allergic contact dermatitis: new sources of exposure. Postepy Dermatol Alergol 2021; 38:555-60. [PMID: 34658693 DOI: 10.5114/ada.2020.95848] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Accepted: 02/11/2020] [Indexed: 11/22/2022] Open
Abstract
Acrylate monomers have a wide range of applications. Since the 1950s, many reports of occupational origin allergic contact dermatitis due to (meth)acrylate monomers have been published. During last decades, (meth)acrylate allergy has undergone an occupational shift from dentistry toward beauty industry and medical devices. The aim of the study was to conduct a literature review on acrylates as a cause of allergic contact dermatitis, current sources of exposure as well as identification of professional groups with an increased risk of this allergy and methods of effective prevention. Database review: Medline search (PubMed), Wiley Online Library and Web of Science base in years 1956–2019 using the following keywords: acrylates, manicurists, dentists, dental technicians, medical devices, occupational exposure, and allergic contact dermatitis. 204 346 articles containing the term ‘acrylates‘ have been found. They include 2 042 articles with the word ‘manicurists’, 169 919 – ‘dentists’, 218 236 – ‘dental technicians’, 2 427 418 – ‘medical devices’. Fifty-nine articles were chosen based on analysis of abstracts and full texts. In the past allergy to acrylates was mainly of occupational origin and dental technicians were the most often affected professional group. Since the long-lasting manicure has become popular, this problem concerns both manicurists and their customers. Moreover, the new significant trend is non-occupational allergic contact dermatitis caused by medical devices especially dedicated to diabetes patients.
Collapse
|
226
|
Zamzam AH, Abdul Wahab AK, Azizan MM, Satapathy SC, Lai KW, Hasikin K. A Systematic Review of Medical Equipment Reliability Assessment in Improving the Quality of Healthcare Services. Front Public Health 2021; 9:753951. [PMID: 34646808 PMCID: PMC8503610 DOI: 10.3389/fpubh.2021.753951] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Accepted: 08/31/2021] [Indexed: 11/17/2022] Open
Abstract
Medical equipment highly contributes to the effectiveness of healthcare services quality. Generally, healthcare institutions experience malfunctioning and unavailability of medical equipment that affects the healthcare services delivery to the public. The problems are frequently due to a deficiency in managing and maintaining the medical equipment condition by the responsible party. The assessment of the medical equipment condition is an important activity during the maintenance and management of the equipment life cycle to increase availability, performance, and safety. The study aimed to perform a systematic review in extracting and categorising the input parameters applied in assessing the medical equipment condition. A systematic searching was undertaken in several databases, including Web of Science, Scopus, PubMed, Science Direct, IEEE Xplore, Emerald, Springer, Medline, and Dimensions, from 2000 to 2020. The searching processes were conducted in January 2020. A total of 16 articles were included in this study by adopting Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA). The review managed to classify eight categories of medical equipment reliability attributes, namely equipment features, function, maintenance requirement, performance, risk and safety, availability and readiness, utilisation, and cost. Applying the eight attributes extracted from computerised asset maintenance management system will assist the clinical engineers in assessing the reliability of medical equipment utilised in healthcare institution. The reliability assessment done in these eight attributes will aid clinical engineers in executing a strategic maintenance action, which can increase the equipment's availability, upkeep the performance, optimise the resources, and eventually contributes in providing effective healthcare service to the community. Finally, the recommendations for future works are presented at the end of this study.
Collapse
Affiliation(s)
- Aizat Hilmi Zamzam
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia.,Engineering Services Department, Ministry of Health Malaysia, Putrajaya, Malaysia
| | - Ahmad Khairi Abdul Wahab
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Muhammad Mokhzaini Azizan
- Department of Electrical and Electronic Engineering, Faculty of Engineering and Built Environment, Universiti Sains Islam Malaysia, Nilai, Malaysia
| | - Suresh Chandra Satapathy
- School of Computer Engineering, Kalinga Institute of Industrial Technology, Deemed to Be University, Bhubaneswar, India
| | - Khin Wee Lai
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia
| | - Khairunnisa Hasikin
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
227
|
Giovagnoli MR, Ciucciarelli S, Castrichella L, Giansanti D. Artificial Intelligence in Digital Pathology: What Is the Future? Part 2: An Investigation on the Insiders. Healthcare (Basel) 2021; 9:healthcare9101347. [PMID: 34683027 PMCID: PMC8544344 DOI: 10.3390/healthcare9101347] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 10/08/2021] [Accepted: 10/09/2021] [Indexed: 01/01/2023] Open
Abstract
Motivation: This study deals with the introduction of artificial intelligence (AI) in digital pathology (DP). The study starts from the highlights of a companion paper. Objective: The aim was to investigate the consensus and acceptance of the insiders on this issue. Procedure: An electronic survey based on the standardized package Microsoft Forms (Microsoft, Redmond, WA, USA) was proposed to a sample of biomedical laboratory technicians (149 admitted in the study, 76 males, 73 females, mean age 44.2 years). Results: The survey showed no criticality. It highlighted (a) the good perception of the basic training on both groups, and (b) a uniformly low perceived knowledge of AI (as arisen from the graded questions). Expectations, perceived general impact, perceived changes in the work-flow, and worries clearly emerged in the study. Conclusions: The of AI in DP is an unstoppable process, as well as the increase of the digitalization in the health domain. Stakeholders must not look with suspicion towards AI, which can represent an important resource, but should invest in monitoring and consensus training initiatives based also on electronic surveys.
Collapse
Affiliation(s)
- Maria Rosaria Giovagnoli
- Facoltà di Medicina e Psicologia, Università Sapienza Roma, Piazzale Aldo Moro, 00185 Rome, Italy; (M.R.G.); (S.C.); (L.C.)
| | - Sara Ciucciarelli
- Facoltà di Medicina e Psicologia, Università Sapienza Roma, Piazzale Aldo Moro, 00185 Rome, Italy; (M.R.G.); (S.C.); (L.C.)
| | - Livia Castrichella
- Facoltà di Medicina e Psicologia, Università Sapienza Roma, Piazzale Aldo Moro, 00185 Rome, Italy; (M.R.G.); (S.C.); (L.C.)
| | - Daniele Giansanti
- Centre Tisp, Istituto Superiore di Sanità, 00161 Rome, Italy
- Correspondence: ; Tel.: +39-06-49902701
| |
Collapse
|
228
|
Bilia AR, Corazziari ES, Govoni S, Mugelli A, Racchi M. Medical Devices Made of Substances: Possible Innovation and Opportunities for Complex Natural Products. Planta Med 2021; 87:1110-1116. [PMID: 34359085 PMCID: PMC8536642 DOI: 10.1055/a-1511-8558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Accepted: 05/13/2021] [Indexed: 06/13/2023]
Abstract
The novel Regulation 2017/745/EC on medical devices introduces and strengthens the role of "medical devices made of substances", which mostly include substances of natural origin. Natural products may follow different regulations, from food to therapeutics. Concerning their isolated constituents, extracts are characterized by a complexity that is not easily tackled from both a scientific and a regulatory point of view, but more importantly, from a therapeutic point of view. The evidence-based approach applied to isolated molecules requires appropriate evidence of quality, efficacy, and safety. The same needs must be reached for complex substances by finding appropriate methods to generate this evidence, and in addition, defining an appropriate regulatory field for them. From a scientific point of view, new methods, such as those proposed by systems biology, are available and applicable to complex substances. From a regulatory point of view, Directive 2001/83/EC on medicinal products seems to be modeled on single (or combinations of single) molecule products. On the other hand, Regulation 2017/745/EC on medical devices seems to apply to complex substances without derogating on quality, efficacy, and safety. The regulation specifically names and strengthens medical devices that include substances, mostly of natural origin, introducing the official term "medical devices made of substances". This paper discusses and proposes an interpretation of important terms connected to this legislation, regarding both scientific and regulatory issues, and the opportunities the regulation may give for innovation and therapeutic improvement with natural complex substances.
Collapse
Affiliation(s)
- Anna Rita Bilia
- Department of Chemistry “Ugo Schiff,” University of Florence, Sesto Fiorentino, Florence, Italy
| | | | - Stefano Govoni
- Department of Drug Sciences, University of Pavia, Pavia, Italy
| | - Alessandro Mugelli
- Department of Neurosciences, Psychology, Drug Research and Child Health, Section of Pharmacology and Toxicology, University of Florence, Florence, Italy
| | - Marco Racchi
- Department of Drug Sciences, University of Pavia, Pavia, Italy
| |
Collapse
|
229
|
Fathelrahman AI. Medical Devices-Related Counseling Practices Among Community Pharmacists: A Nationwide Cross-Sectional Study from Saudi Arabia. Integr Pharm Res Pract 2021; 10:113-125. [PMID: 34532279 PMCID: PMC8439968 DOI: 10.2147/iprp.s310027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2021] [Accepted: 08/27/2021] [Indexed: 11/24/2022] Open
Abstract
Objective The current study was conducted to assess medical devices-related counseling practices among community pharmacists in Saudi Arabia. Methodology This was a cross-sectional study conducted among community pharmacists from Saudi Arabia using a convenience sampling technique. An online questionnaire based on Google forms was used to collect data. Descriptive and inferential analyses were conducted using SPSS statistics 22. Student t-test, one way ANOVA, and Pearson correlation statistics were used where applicable. Results with a p-value of <0.05 were considered statistically significant. Results One thousand and six community pharmacists responded to the survey. Males’ rating of their ability to operate medical devices was significantly higher than females (overall average score of 3.8 versus 3.5, p=0.033). As years of experience increased there were slight but significant increases in the overall scores on ability to operate medical devices (p=0.002) and confidence to counsel patients about the devices (p=0.032). Those who got a board certification used devices for self-treatment significantly more than their counterparts (on average 6.9 devices versus 5.2, p=0.003). Those who received clinical training reported higher rates of ability to use/operate devices (p=0.011), confidence to counsel patients on devices (p=0.001), and counseling practice (p=0.044) than those who did not receive clinical training. Conclusion The present study revealed good to very good self-reported medical devices-related counseling practices. There is a need for more future rigorous research to evaluate pharmacists' actual practice in this area. Pharmacy educators and CPD programs should pay attention to updating pharmacists’ knowledge and skills and improve their contribution to medical devices supportive services.
Collapse
|
230
|
Dendooven E, Dirinck E, Foubert K, Aerts O. "Re-testing" suggests that cosensitizations to isobornyl acrylate and sesquiterpene lactones may be due to cross-reactivity. Contact Dermatitis 2021; 86:57-59. [PMID: 34519361 DOI: 10.1111/cod.13972] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 09/07/2021] [Accepted: 09/09/2021] [Indexed: 01/23/2023]
Affiliation(s)
- Ella Dendooven
- Department of Dermatology, University Hospital Antwerp (UZA) and Research Group Immunology, Infla-Med Centre of Excellence, University of Antwerp, Antwerp, Belgium.,Research Group Natural Products & Food - Research and Analysis (NatuRA), Department of Pharmaceutical Sciences, University of Antwerp, Antwerp, Belgium
| | - Eveline Dirinck
- Department of Endocrinology-Diabetology-Metabolic disease, University Hospital Antwerp (UZA) and University of Antwerp, Antwerp, Belgium
| | - Kenn Foubert
- Research Group Natural Products & Food - Research and Analysis (NatuRA), Department of Pharmaceutical Sciences, University of Antwerp, Antwerp, Belgium
| | - Olivier Aerts
- Department of Dermatology, University Hospital Antwerp (UZA) and Research Group Immunology, Infla-Med Centre of Excellence, University of Antwerp, Antwerp, Belgium
| |
Collapse
|
231
|
Oh SR, Seo YD, Lee E, Kim YG. A Comprehensive Survey on Security and Privacy for Electronic Health Data. Int J Environ Res Public Health 2021; 18:ijerph18189668. [PMID: 34574593 PMCID: PMC8465695 DOI: 10.3390/ijerph18189668] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 09/01/2021] [Accepted: 09/09/2021] [Indexed: 12/01/2022]
Abstract
Recently, the integration of state-of-the-art technologies, such as modern sensors, networks, and cloud computing, has revolutionized the conventional healthcare system. However, security concerns have increasingly been emerging due to the integration of technologies. Therefore, the security and privacy issues associated with e-health data must be properly explored. In this paper, to investigate the security and privacy of e-health systems, we identified major components of the modern e-health systems (i.e., e-health data, medical devices, medical networks and edge/fog/cloud). Then, we reviewed recent security and privacy studies that focus on each component of the e-health systems. Based on the review, we obtained research taxonomy, security concerns, requirements, solutions, research trends, and open challenges for the components with strengths and weaknesses of the analyzed studies. In particular, edge and fog computing studies for e-health security and privacy were reviewed since the studies had mostly not been analyzed in other survey papers.
Collapse
Affiliation(s)
- Se-Ra Oh
- Miro Corporation, Incheon 21988, Korea;
| | - Young-Duk Seo
- Department of Computer Engineering, Inha University, Incheon 22212, Korea;
| | - Euijong Lee
- Department of Computer Science, Chungbuk National University, Cheongju 28644, Korea;
| | - Young-Gab Kim
- Department of Computer and Information Security, and Convergence Engineering for Intelligent Drone, Sejong University, Seoul 05006, Korea
- Correspondence:
| |
Collapse
|
232
|
Rohner NA, Learn GD, Wiggins MJ, Woofter RT, von Recum HA. Characterization of Inflammatory and Fibrotic Encapsulation Responses of Implanted Materials with Bacterial Infection. ACS Biomater Sci Eng 2021; 7:4474-4482. [PMID: 34464101 DOI: 10.1021/acsbiomaterials.1c00505] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Medical device infections are costly, while preclinical assessment of antimicrobial properties for new materials is time intensive and imperfect at capturing the interrelated aspects of infection response and wound resolution. Herein, we developed an in vivo model for quantification of inflammatory and biocompatibility responses in the presence of a sustained implant-associated infection. The antimicrobial effectiveness of commercially available polymer materials was compared to that of thermoplastic polyurethane (TPU) materials modified with putative antimicrobial strategies as example test materials. Materials were incubated with bioluminescent Escherichia coli prior to implantation in a dorsal subcutaneous pocket in rats with an additional intraluminal bolus of bacteria. Infection kinetics were monitored with bioluminescence, and inflammatory infiltrate and fibrous capsule thickness were determined from stained histological sections. Our model resulted in a persistent infection, sensitive to antimicrobial effects, as the materials modified with a putative antimicrobial surface were able to significantly reduce the level of infection in animals at day 4 postimplantation with efficacy similar to that of commercially available antimicrobial drug-eluting polymers (positive controls). At day 30 postimplantation, the antimicrobial surface modified TPU tubing was found to promote complete elimination of intraluminal bacteria in the absence of antibiotics. Differences were also measurable in acute inflammation, as Wright-Giemsa staining demonstrated reduced inflammatory cell infiltration at day 4 postimplantation for antimicrobial TPU materials. Additionally, antimicrobial materials exhibited reduced fibrous capsule thickness coinciding with infection resolution, as compared to unmodified TPU controls. The developed model can be utilized for testing antimicrobial polymers in the context of a prolonged infection while also revealing concurrent differences in the infiltrating immune cell profiles and fibrous capsule thickness, thus improving the relevance of preclinical medical device material testing.
Collapse
Affiliation(s)
- Nathan A Rohner
- Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106, United States
| | - Greg D Learn
- Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106, United States
| | - Michael J Wiggins
- Lubrizol Advanced Materials Inc., Brecksville, Ohio 44141, United States
| | - Ricky T Woofter
- Lubrizol Advanced Materials Inc., Brecksville, Ohio 44141, United States
| | - Horst A von Recum
- Department of Biomedical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106, United States
| |
Collapse
|
233
|
Culmer P, Davis Birch W, Waters I, Keeling A, Osnes C, Jones D, de Boer G, Hetherington R, Ashton S, Latham M, Beacon T, Royston T, Miller R, Littlejohns A, Parmar J, Lawton T, Murdoch S, Brettle D, Musasizi R, Nampiina G, Namulema E, Kapur N. The LeVe CPAP System for Oxygen-Efficient CPAP Respiratory Support: Development and Pilot Evaluation. Front Med Technol 2021; 3:715969. [PMID: 35047948 PMCID: PMC8757765 DOI: 10.3389/fmedt.2021.715969] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Accepted: 07/29/2021] [Indexed: 12/04/2022] Open
Abstract
Background: The COVID-19 pandemic, caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has placed a significant demand on healthcare providers (HCPs) to provide respiratory support for patients with moderate to severe symptoms. Continuous Positive Airway Pressure (CPAP) non-invasive ventilation can help patients with moderate symptoms to avoid the need for invasive ventilation in intensive care. However, existing CPAP systems can be complex (and thus expensive) or require high levels of oxygen, limiting their use in resource-stretched environments. Technical Development + Testing: The LeVe ("Light") CPAP system was developed using principles of frugal innovation to produce a solution of low complexity and high resource efficiency. The LeVe system exploits the air flow dynamics of electric fan blowers which are inherently suited to delivery of positive pressure at appropriate flow rates for CPAP. Laboratory evaluation demonstrated that performance of the LeVe system was equivalent to other commercially available systems used to deliver CPAP, achieving a 10 cm H2O target pressure within 2.4% RMS error and 50-70% FiO2 dependent with 10 L/min oxygen from a commercial concentrator. Pilot Evaluation: The LeVe CPAP system was tested to evaluate safety and acceptability in a group of ten healthy volunteers at Mengo Hospital in Kampala, Uganda. The study demonstrated that the system can be used safely without inducing hypoxia or hypercapnia and that its use was well-tolerated by users, with no adverse events reported. Conclusions: To provide respiratory support for the high patient numbers associated with the COVID-19 pandemic, healthcare providers require resource efficient solutions. We have shown that this can be achieved through frugal engineering of a CPAP ventilation system, in a system which is safe for use and well-tolerated in healthy volunteers. This approach may also benefit other respiratory conditions which often go unaddressed in Low and Middle Income Countries (LMICs) for want of context-appropriate technology designed for the limited oxygen resources available.
Collapse
Affiliation(s)
- Pete Culmer
- School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
| | - W. Davis Birch
- School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
| | - I. Waters
- School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
| | - A. Keeling
- School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
- School of Dentistry, University of Leeds, Leeds, United Kingdom
| | - C. Osnes
- School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
- School of Dentistry, University of Leeds, Leeds, United Kingdom
| | - D. Jones
- School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
| | - G. de Boer
- School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
| | - R. Hetherington
- School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
| | - S. Ashton
- Leeds Teaching Hospitals Trust, Leeds, United Kingdom
| | - M. Latham
- Leeds Teaching Hospitals Trust, Leeds, United Kingdom
| | - T. Beacon
- Medical Aid International Ltd., Bedford, United Kingdom
| | - T. Royston
- Medical Aid International Ltd., Bedford, United Kingdom
| | - R. Miller
- Medical Aid International Ltd., Bedford, United Kingdom
| | | | - J. Parmar
- Leeds Teaching Hospitals Trust, Leeds, United Kingdom
| | - Tom Lawton
- Bradford Teaching Hospitals National Health Service (NHS) Foundation Trust, Bradford, United Kingdom
| | - S. Murdoch
- Leeds Teaching Hospitals Trust, Leeds, United Kingdom
| | - D. Brettle
- Leeds Teaching Hospitals Trust, Leeds, United Kingdom
| | | | | | | | - N. Kapur
- School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
| |
Collapse
|
234
|
Salvatore MM, Maione A, Albarano L, de Alteriis E, Carraturo F, Andolfi A, Salvatore F, Galdiero E, Guida M. An Integrated Analysis of Intracellular Metabolites and Virulence Gene Expression during Biofilm Development of a Clinical Isolate of Candida tropicalis on Distinct Surfaces. Int J Mol Sci 2021; 22:9038. [PMID: 34445744 DOI: 10.3390/ijms22169038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Accepted: 08/19/2021] [Indexed: 11/18/2022] Open
Abstract
Emergence of Candida tropicalis, which causes potential life-threatening invasive candidiasis, is often associated with colonization of medical devices as biofilm. Biofilm plays an important role in the virulence of the pathogen because of its complex structure, which provides resistance to conventional antimicrobials. In this study, the metabolic response of a clinical strain of C. tropicalis colonizing three distinct surfaces (polytetrafluoroethylene (PTFE), polystyrene, and polycarbonate) as well as the expression of virulence and stress related genes (ALS3, Hsp21, SAP1, SAP2, SAP3, and CYR1), were explored. Our results showed that lesser biofilm was developed on PTFE compared to polystyrene and polycarbonate. GS-MS metabolic analysis identified a total of 36 metabolites in the intracellular extract of cells grown on polystyrene, polycarbonate, and PTFE, essentially belonging to central carbon metabolism, amino acids, and lipids metabolism. The metabolic analysis showed that saturated and unsaturated fatty acids are preferentially produced during biofilm development on polycarbonate, whereas trehalose and vitamin B6, known as cellular protectors against a variety of stressors, were characteristic of biofilm on PTFE. The results of the transcriptomic analysis consider the different degrees of colonization of the three substrates, being CYR1, which encodes the component of signaling pathway of hyphal formation-cAMP-PKA, downregulated in PTFE biofilm compared to polycarbonate or polystyrene biofilms, while Hsp21 was upregulated in concomitance with the potential unfavorable conditions for biofilm formation on PTFE. Overall, this work provides new insights into the knowledge of C. tropicalis biofilm development on surfaces of medical relevance in the perspective of improving the management of Candida infections.
Collapse
|
235
|
Shahid A, Aslam B, Muzammil S, Aslam N, Shahid M, Almatroudi A, Allemailem KS, Saqalein M, Nisar MA, Rasool MH, Khurshid M. The prospects of antimicrobial coated medical implants. J Appl Biomater Funct Mater 2021; 19:22808000211040304. [PMID: 34409896 DOI: 10.1177/22808000211040304] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
Abstract
The implants are increasingly being a part of modern medicine in various surgical procedures for functional or cosmetic purposes. The progressive use of implants is associated with increased infectious complications and prevention of such infections always remains precedence in the clinical settings. The preventive approaches include the systemic administration of antimicrobial agents before and after the surgical procedures as well as the local application of antibiotics. The relevant literature and existing clinical practices have highlighted the role of antimicrobial coating approaches in the prevention of implants associated infections, although the applications of these strategies are not yet standardized, and the clinical efficacy is not much clear. The adequate data from the randomized control trials is challenging because of the unavailability of a large sample size although it is compulsory in this context to assess the clinical efficacy of preemptive practices. This review compares the efficacy of preventive approaches and the prospects of antimicrobial-coated implants in preventing implant-related infections.
Collapse
Affiliation(s)
- Aqsa Shahid
- Department of Microbiology, Government College University, Faisalabad, Pakistan
| | - Bilal Aslam
- Department of Microbiology, Government College University, Faisalabad, Pakistan
| | - Saima Muzammil
- Department of Microbiology, Government College University, Faisalabad, Pakistan
| | - Nosheen Aslam
- Department of Biochemistry, Government College University, Faisalabad, Pakistan
| | - Muhammad Shahid
- Department of Bioinformatics and Biotechnology, Government College University, Faisalabad, Pakistan
| | - Ahmad Almatroudi
- Department of Medical Laboratories, College of Applied Medical Sciences, Qassim University, Buraydah, Saudi Arabia
| | - Khaled S Allemailem
- Department of Medical Laboratories, College of Applied Medical Sciences, Qassim University, Buraydah, Saudi Arabia
| | - Muhammad Saqalein
- Department of Microbiology, Government College University, Faisalabad, Pakistan
| | - Muhammad Atif Nisar
- Department of Microbiology, Government College University, Faisalabad, Pakistan.,College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | | | - Mohsin Khurshid
- Department of Microbiology, Government College University, Faisalabad, Pakistan
| |
Collapse
|
236
|
Matsuda T, Ohura N, Mineta K, Ho M, Kaku I, Ishii K, Inoue M, Ichioka S, Tanaka R, Kawamoto A, Terashi H, Kishi K, Kobayashi Y. Hard-to-heal wound treatment medical devices: clinical trial protocol in Japan. J Wound Care 2021; 30:666-676. [PMID: 34382845 DOI: 10.12968/jowc.2021.30.8.666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In consultation with academia and the Pharmaceuticals and Medical Devices Agency (PMDA), we have developed guidance for drafting protocols for clinical trials concerning medical devices for the healing of hard-to-heal wounds without ischaemia. The guidance summarises the validity of single-arm trials for hard-to-heal wounds, the definition of hard-to-heal wounds without ischaemia, methods of patient enrolment and clinical endpoints. This review focuses on the logical thinking process that was used when establishing the guidance for improving the efficiency of clinical trials concerning medical devices for hard-to-heal wounds. We particularly focused on the feasibility of conducting single-arm trials and also tried to clarify the definition of hard-to-heal wounds. If the feasibility of randomised control trials is low, conducting single-arm trials should be considered for the benefit of patients. In addition, hard-to-heal wounds were defined as meeting the following two conditions: wounds with a wound area reduction <50% at four weeks despite appropriate standards of care; and wounds which cannot be closed by a relatively simple procedure (for example, suture, skin graft and small flaps). Medical devices for hard-to-heal wound healing are classified into two types: (1) devices for promoting re-epithelialisation; and (2) devices for improving the wound bed. For medical devices for promoting re-epithelialisation, we suggest setting complete wound closure, percent wound area reduction or distance moved by the wound edge as the primary endpoint in single-arm trials for hard-to-heal wounds. For medical devices for improving the wound bed, we suggest setting the period in which wounds can be closed by secondary intention or a simple procedure, such as the primary endpoint.
Collapse
Affiliation(s)
| | - Norihiko Ohura
- Department of Plastic and Reconstructive Surgery, Kyorin University School of Medicine, Tokyo, Japan
| | - Koji Mineta
- Japan Agency for Medical Research and Development, Tokyo, Japan
| | - Mami Ho
- Pharmaceuticals and Medical Devices Agency, Tokyo, Japan
| | - I Kaku
- Pharmaceuticals and Medical Devices Agency, Tokyo, Japan
| | - Kensuke Ishii
- Pharmaceuticals and Medical Devices Agency, Tokyo, Japan
| | - Madoka Inoue
- Pharmaceuticals and Medical Devices Agency, Tokyo, Japan
| | - Shigeru Ichioka
- Department of Plastic Surgery, Saitama Medical University, Saitama, Japan
| | - Rica Tanaka
- Department of Plastic and Reconstructive Surgery, Juntendo University School of Medicine, Tokyo, Japan
| | | | - Hiroto Terashi
- Department of Plastic Surgery, Kobe University, Graduate School of Medicine, Kobe, Japan
| | - Kazuo Kishi
- Department of Plastic and Reconstructive Surgery, School of Medicine, Keio University, Tokyo, Japan
| | - Yoko Kobayashi
- Pharmaceuticals and Medical Devices Agency, Tokyo, Japan
| | | |
Collapse
|
237
|
Ferrari E, Khan M, Mantel J, Wallbank R. The assessment of muscle fatigue in orthopedic surgeons, by comparing manual versus automated broaching in simulated total hip arthroplasty. Proc Inst Mech Eng H 2021; 235:1471-1478. [PMID: 34281446 DOI: 10.1177/09544119211034386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Total hip arthroplasty procedures are physically demanding for surgeons. Repetitive mallet swings to impact a surgical handle (impactions), can lead to muscle fatigue, discomfort, and injuries. The use of an automated surgical hammer may reduce fatigue and increase surgical efficiency. The aim of this study was to compare the effect of repeated manual and automated impactions on the user's muscle activation, by means of surface electromyography. Surface electromyography signals were recorded from eight muscles of seven (n = 7) orthopedic surgeons during repetitions of manual and automated impactions, to reach the same surgical outcome (broaching depth). Qualitative data was also captured to track the perceived fatigue and preferences of impaction modalities after completion of impaction tasks. Time to complete tasks, muscle activation, and muscle fatigue were quantified. Results showed a significant decrease in time required to reach the same broaching depth for the automated method compared to manual impactions (p = 0.001). A reduction in muscle fatigue and activation of right Brachioradialis muscle was observed during automated impactions (p = 0.018). A significant difference in fatigue was observed, with lower level of fatigue during automated impactions (p = 0.001). These results suggest that an automated surgical workflow might reduce the exposure to the impaction task and, therefore, muscle fatigue, with a reduced activation of the most engaged muscles. The study suggests that the burden on the user can be reduced by a change in the surgical methodology to perform broaching in total hip arthroplasty, which could potentially benefit surgical efficiency and reduce the risk of fatigue-based errors during a procedure.
Collapse
Affiliation(s)
| | - Mariam Khan
- DePuy International Limited, Beeston, Leeds, UK
| | - Jack Mantel
- DePuy International Limited, Beeston, Leeds, UK
| | | |
Collapse
|
238
|
Brönneke JB, Müller J, Mouratis K, Hagen J, Stern AD. Regulatory, Legal, and Market Aspects of Smart Wearables for Cardiac Monitoring. Sensors (Basel) 2021; 21:s21144937. [PMID: 34300680 PMCID: PMC8309890 DOI: 10.3390/s21144937] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 07/09/2021] [Accepted: 07/13/2021] [Indexed: 01/27/2023]
Abstract
In the area of cardiac monitoring, the use of digitally driven technologies is on the rise. While the development of medical products is advancing rapidly, allowing for new use-cases in cardiac monitoring and other areas, regulatory and legal requirements that govern market access are often evolving slowly, sometimes creating market barriers. This article gives a brief overview of the existing clinical studies regarding the use of smart wearables in cardiac monitoring and provides insight into the main regulatory and legal aspects that need to be considered when such products are intended to be used in a health care setting. Based on this brief overview, the article elaborates on the specific requirements in the main areas of authorization/certification and reimbursement/compensation, as well as data protection and data security. Three case studies are presented as examples of specific market access procedures: the USA, Germany, and Belgium. This article concludes that, despite the differences in specific requirements, market access pathways in most countries are characterized by a number of similarities, which should be considered early on in product development. The article also elaborates on how regulatory and legal requirements are currently being adapted for digitally driven wearables and proposes an ongoing evolution of these requirements to facilitate market access for beneficial medical technology in the future.
Collapse
Affiliation(s)
- Jan Benedikt Brönneke
- Health Innovation Hub, Torstr. 223, 10785 Berlin, Germany; (J.H.); (A.D.S.)
- Correspondence:
| | - Jennifer Müller
- Helios Health Institute, Helios Health, Friedrichstraße 136, 10117 Berlin, Germany;
| | - Konstantinos Mouratis
- Herzzentrum Leipzig, Universitätsklinik für Kardiologie, Strümpellstraße 39, 04289 Leipzig, Germany;
- Leipzig Heart Institute, Russenstraße 69a, 04289 Leipzig, Germany
| | - Julia Hagen
- Health Innovation Hub, Torstr. 223, 10785 Berlin, Germany; (J.H.); (A.D.S.)
| | - Ariel Dora Stern
- Health Innovation Hub, Torstr. 223, 10785 Berlin, Germany; (J.H.); (A.D.S.)
- Harvard Business School, Harvard University, Morgan Hall 433, Soldiers Field Road, Boston, MA 02163, USA
- Hasso-Plattner-Institute, Prof.-Dr.-Helmert-Straße 2-3, 14482 Potsdam, Germany
| |
Collapse
|
239
|
Giovagnoli MR, Giansanti D. Artificial Intelligence in Digital Pathology: What Is the Future? Part 1: From the Digital Slide Onwards. Healthcare (Basel) 2021; 9:healthcare9070858. [PMID: 34356236 PMCID: PMC8304979 DOI: 10.3390/healthcare9070858] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 07/01/2021] [Accepted: 07/04/2021] [Indexed: 12/13/2022] Open
Abstract
This commentary aims to address the field of Artificial intelligence (AI) in Digital Pathology (DP) both in terms of the global situation and research perspectives. It has four polarities. First, it revisits the evolutions of digital pathology with particular care to the two fields of the digital cytology and the digital histology. Second, it illustrates the main fields in the employment of AI in DP. Third, it looks at the future directions of the research challenges from both a clinical and technological point of view. Fourth, it discusses the transversal problems among these challenges and implications and introduces the immediate work to implement.
Collapse
Affiliation(s)
| | - Daniele Giansanti
- Centre Tisp, Istituto Superiore di Sanità, 00161 Roma, Italy
- Correspondence: ; Tel.: +39-06-49902701
| |
Collapse
|
240
|
Benz HL, Caldwell B, Ruiz JP, Saha A, Ho M, Christopher S, Bardot D, Sheehan M, Donnelly A, McLaughlin L, Mange B, Hauber AB, Gwinn K, Heetderks WJ, Sheldon M. Patient-Centered Identification of Meaningful Regulatory Endpoints for Medical Devices to Treat Parkinson's Disease. MDM Policy Pract 2021; 6:23814683211021380. [PMID: 34277950 PMCID: PMC8255597 DOI: 10.1177/23814683211021380] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2019] [Accepted: 04/30/2021] [Indexed: 11/16/2022] Open
Abstract
Introduction. A growing literature has developed on identifying outcomes that matter to patients. This study demonstrates an approach involving patient and regulatory perspectives to identify outcomes that are meaningful in the context of medical devices for Parkinson’s disease (PD). Methods. A systematic process was used for specifying relevant regulatory endpoints by synthesizing inputs of various sources and stakeholders. First, a literature review was conducted to identify important benefits, risks, and other considerations for medical devices to treat PD; patient discussion groups (n = 6) were conducted to refine the list of considerations, followed by a survey (n = 29) to prioritize them; and patient and Food and Drug Administration (FDA) reviewers informed specification of the final endpoints. Two FDA clinicians gave clinical and regulatory perspectives at each step. Results. Movement symptoms were ranked as most important (ranked 1 or 2 by 72% of participants) and psychological and cognitive symptoms as the next most important (ranked 1 or 2 by 52% of participants). Within movement symptoms, falls, impaired movement, bradykinesia, resting tremor, stiffness, and rigidity were ranked highly. Overall, nine attributes were identified and prioritized as patient-centric for use in clinical trial design and quantitative patient preference studies. These attributes were benefits and risks related to therapeutics for PD as well as other considerations, including time until a medical device is available for patient use. Discussion. This prospective approach identified meaningful and relevant benefits, risks, and other considerations that may be used for clinical trial design and quantitative patient preference studies. Although PD was the focus of this study, the approach can be used to study patient perspectives about other disease or treatment areas.
Collapse
Affiliation(s)
- Heather L Benz
- US FDA Center for Devices and Radiological Health, Silver Spring, Maryland
| | - Brittany Caldwell
- US FDA Center for Devices and Radiological Health, Silver Spring, Maryland
| | - John P Ruiz
- US FDA Center for Devices and Radiological Health, Silver Spring, Maryland
| | - Anindita Saha
- US FDA Center for Devices and Radiological Health, Silver Spring, Maryland
| | - Martin Ho
- US FDA Center for Devices and Radiological Health, Silver Spring, Maryland
| | | | - Dawn Bardot
- Medical Device Innovation Consortium, Arlington, Virginia
| | - Margaret Sheehan
- The Michael J. Fox Foundation for Parkinson's Research, New York, New York
| | - Anne Donnelly
- The Michael J. Fox Foundation for Parkinson's Research, New York, New York
| | - Lauren McLaughlin
- The Michael J. Fox Foundation for Parkinson's Research, New York, New York
| | - Brennan Mange
- RTI Health Solutions, Research Triangle Park, North Carolina
| | - A Brett Hauber
- RTI Health Solutions, Research Triangle Park, North Carolina
| | - Katrina Gwinn
- US FDA Center for Devices and Radiological Health, Silver Spring, Maryland
| | | | - Murray Sheldon
- US FDA Center for Devices and Radiological Health, Silver Spring, Maryland
| |
Collapse
|
241
|
Artun ED, Şahin B. Evaluation of the Availability of Hospital-Based Health Technology Assessment in Public and Private Hospitals in Turkey: Ankara Province Sample. Value Health Reg Issues 2021; 25:165-171. [PMID: 34225101 DOI: 10.1016/j.vhri.2021.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Revised: 02/01/2021] [Accepted: 03/11/2021] [Indexed: 11/17/2022]
Abstract
OBJECTIVES This study aimed to investigate the extent to which hospitals and managers take the hospital-based health technology assessment (HB-HTA) approach into account in their decision-making processes regarding medical device/equipment acquisition. METHODS The questionnaire was developed as a data collection tool and administered to a total of 186 administrators from 33 hospitals in Ankara. RESULTS All domains of HB-HTA are taken into consideration in both private and public hospitals but more in private hospitals than public hospitals (P<.001). The importance given to the domains of HB-HTA approach varies according to the characteristics of the hospitals and managers. In addition, it was seen that training hospitals were more likely to consider clinical effectiveness, and safety in specialty hospitals was more important. In addition, medical managers focus more on the clinical effectiveness, whereas administrative and financial managers are more concerned with cost/economic effectiveness. Moreover, the organizational aspects dimension of the HB-HTA was taken into account as the working duration of the managers in the health sector increased. CONCLUSIONS Hospitals and managers with different characteristics benefit from the domains of the approach at different levels. To contribute to the use of HB-HTA approach in hospitals and to increase awareness, regional initiatives can be undertaken by encouraging hospitals.
Collapse
Affiliation(s)
- Elife Dilmaç Artun
- Ministry of Health, General Directorate of Health Services, Department of Health Technology Assessment, T.C. Sağlık Bakanlığı Üniversiteler Mah., Ankara, Turkey.
| | - Bayram Şahin
- Faculty of Economics and Administrative Sciences, Department of Health Management, Hacettepe University, Ankara, Turkey.
| |
Collapse
|
242
|
Katz N, Dworkin RH, North R, Thomson S, Eldabe S, Hayek SM, Kopell BH, Markman J, Rezai A, Taylor RS, Turk DC, Buchser E, Fields H, Fiore G, Ferguson M, Gewandter J, Hilker C, Jain R, Leitner A, Loeser J, McNicol E, Nurmikko T, Shipley J, Singh R, Trescot A, van Dongen R, Venkatesan L. Research design considerations for randomized controlled trials of spinal cord stimulation for pain: Initiative on Methods, Measurement, and Pain Assessment in Clinical Trials/Institute of Neuromodulation/International Neuromodulation Society recommendations. Pain 2021; 162:1935-1956. [PMID: 33470748 PMCID: PMC8208090 DOI: 10.1097/j.pain.0000000000002204] [Citation(s) in RCA: 36] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 12/10/2020] [Accepted: 12/15/2020] [Indexed: 12/17/2022]
Abstract
ABSTRACT Spinal cord stimulation (SCS) is an interventional nonpharmacologic treatment used for chronic pain and other indications. Methods for evaluating the safety and efficacy of SCS have evolved from uncontrolled and retrospective studies to prospective randomized controlled trials (RCTs). Although randomization overcomes certain types of bias, additional challenges to the validity of RCTs of SCS include blinding, choice of control groups, nonspecific effects of treatment variables (eg, paresthesia, device programming and recharging, psychological support, and rehabilitative techniques), and safety considerations. To address these challenges, 3 professional societies (Initiative on Methods, Measurement, and Pain Assessment in Clinical Trials, Institute of Neuromodulation, and International Neuromodulation Society) convened a meeting to develop consensus recommendations on the design, conduct, analysis, and interpretation of RCTs of SCS for chronic pain. This article summarizes the results of this meeting. Highlights of our recommendations include disclosing all funding source and potential conflicts; incorporating mechanistic objectives when possible; avoiding noninferiority designs without internal demonstration of assay sensitivity; achieving and documenting double-blinding whenever possible; documenting investigator and site experience; keeping all information provided to patients balanced with respect to expectation of benefit; disclosing all information provided to patients, including verbal scripts; using placebo/sham controls when possible; capturing a complete set of outcome assessments; accounting for ancillary pharmacologic and nonpharmacologic treatments in a clear manner; providing a complete description of intended and actual programming interactions; making a prospective ascertainment of SCS-specific safety outcomes; training patients and researchers on appropriate expectations, outcome assessments, and other key aspects of study performance; and providing transparent and complete reporting of results according to applicable reporting guidelines.
Collapse
Affiliation(s)
- Nathaniel Katz
- Corresponding author. Address: WCG Analgesic Solutions, Wayland, MA, USA. Tel.: 1-617-948-5161. E-mail address: (N. Katz)
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
243
|
Webber CM, Chen AL, Gebben DJ, Saha A, Tarver ME. Measuring Patient Preferences at the FDA Center for Devices and Radiological Health: Reflections and Projections. Value Health 2021; 24:1024-1029. [PMID: 34243826 DOI: 10.1016/j.jval.2021.01.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2020] [Revised: 01/23/2021] [Accepted: 01/27/2021] [Indexed: 06/13/2023]
Abstract
OBJECTIVES Patient preference information (PPI) is a way to incorporate the patient voice in the evaluation of medical devices. The US Food and Drug Administration (FDA) Center for Devices and Radiological Health (CDRH) has been working to encourage the voluntary inclusion of PPI throughout the medical device lifecycle for nearly a decade. This article reflects CDRH's efforts to encourage collection of PPI and offers perspectives on the future of PPI in the evaluation of medical devices. METHODS CDRH regulatory guidance, public meetings, and collaborations relating to PPI were explored. RESULTS Since 2012 when CDRH issued guidance on how PPI can be used as scientific evidence in the benefit-risk regulatory submission, CDRH has issued 5 subsequent guidance documents expanding on the use of PPI in medical device evaluations. CDRH remains committed to advancing the science and application of PPI in the medical device ecosystem through many collaborations with professional organizations, patient advocacy groups, and academic institutions. By hosting and actively participating in multiple scientific and regulatory public meetings and conferences, CDRH fosters a continuous learning environment where the experience of using PPI in regulatory submissions can be shared. A September 2020 meeting cosponsored by FDA and International Society for Pharmacoeconomics and Outcomes Research (ISPOR) discussed the state of PPI in regulatory applications and beyond. CONCLUSION This article describes these pivotal events that have helped to increase the use of PPI in medical device evaluation as well as discusses future applications of PPI.
Collapse
Affiliation(s)
- Christina M Webber
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, USA
| | - Allen L Chen
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, USA
| | - David J Gebben
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, USA; Department of Economics, Calvin University, Grand Rapids, MI, USA
| | - Anindita Saha
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, USA
| | - Michelle E Tarver
- Center for Devices and Radiological Health, US Food and Drug Administration, Silver Spring, MD, USA.
| |
Collapse
|
244
|
Fathelrahman AI. Medical Device-related Counseling Practice and Barriers among Sudanese Pharmacists: A Questionnaire-Based Study. J Res Pharm Pract 2021; 10:125-132. [PMID: 35198505 PMCID: PMC8809458 DOI: 10.4103/jrpp.jrpp_21_32] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Accepted: 09/19/2021] [Indexed: 11/06/2022] Open
Abstract
Objective: The aim of the present study was to assess medical devices-related counseling practice and barriers among pharmacists. Methods: This was a cross-sectional study conducted using a convenient sample of Sudanese pharmacists. An online-version survey was used to collect data. Findings: One hundred and thirty pharmacists responded to the online survey. Most pharmacists in this sample were master or Ph.D. degree holders (62.3% and 12.3%, respectively), having a clinical training experience (70%) and substantial proportion are board-certified (30%). Medical devices reported to be commonly inquired by patients were blood glucose monitors, nebulizers, blood pressure monitors, dry powder inhalers, and insulin pens. Devices most frequently requiring counselling were blood glucose monitors, blood pressure monitors, syringes, thermometers, nebulizers, dry powder inhalers, insulin, and weighing scales. The most frequently supplied devices reported were syringes, blood glucose monitors, insulin pens, blood pressure monitors, thermometers, nebulizers, and dry powder inhalers. Devices least frequently requiring counselling were implanted devices, respirometers, and stethoscopes. The least frequently supplied devices were respirometers, implanted devices, and heart rate monitors. Conclusion: Medical devices reported to be commonly inquired by patients were most frequently requiring counseling, and most frequently supplied. Findings reflect the availability of devices in the market and pharmacists' response to the needs of their patients. Pharmacists should maintain adequate knowledge about the proper use of medical devices because this is a common patient inquiry.
Collapse
|
245
|
Tramontano M, De Angelis S, Mastrogiacomo S, Princi AA, Ciancarelli I, Frizziero A, Iosa M, Paolucci S, Morone G. Music-based techniques and related devices in neurorehabilitation: a scoping review. Expert Rev Med Devices 2021; 18:733-749. [PMID: 34162284 DOI: 10.1080/17434440.2021.1947793] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Introduction:The music as a powerful, and versatile stimulus for the brain, is at the date sometimes used in neurorehabilitation and proposed as a promising complementary strategy provided in combination with other therapy in individuals with neurological disorders. Different techniques and devices have been developed in the field of the music-based neurorehabilitation.Areas covered:This scoping review analyzes the current scientific literature concerning the different techniques and devices used in the music-supported neurorehabilitation, also focusing on the devices used in music-based therapies in patients with neurological disorders: 46 studies met the inclusion criteria and were included.Expert opinion:Included studies, highlight the potentiality and the versatility of the music-based therapy in the rehabilitation of neurological disorders. The variety of existing techniques allow to applied the music-based therapy in different situations and conditions. Moreover, the wide range of used devices that ranging from the simple musical instruments to the more advanced technologies, allows to develop customized exercises based on the needs of the patient. This review may be considered as a starting point to better design future RCTs that would investigate the effectiveness of music therapy on neurological disorders.
Collapse
Affiliation(s)
| | | | | | | | - Irene Ciancarelli
- Department of Life, Health and Environmental Sciences, University of L'Aquila, L'Aquila, Italy
| | - Antonio Frizziero
- Department of Medicine and Surgery, University of Parma, Parma, Italy
| | - Marco Iosa
- Fondazione Santa Lucia IRCCS, Rome, Italy.,Department of Psychology, University of Rome La Sapienza, Rome, Italy
| | | | | |
Collapse
|
246
|
Dózsa K, Mezei F, Tóth T, Perjés Á, Pollner P. Countrywide survey on utilization of medical devices by GPs in Hungary: advantages of the cluster-practice model. Prim Health Care Res Dev 2021; 22:e34. [PMID: 34184625 DOI: 10.1017/S1463423621000372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND Expectations towards general practitioners (GPs) are continuously increasing to provide a more systematic preventive- and definitive-based care, a wider range of multidisciplinary team-based services and to integrate state-of-the-art digital solutions into daily practice. Aided by development programmes, Hungarian primary care is facing the challenge to fulfil its role as the provider of comprehensive, high quality, patient-centred, preventive care, answering the challenges caused by non-communicable diseases (NCDs). AIM The article aims to provide an insight into the utilization of simple, digital, medical devices. We show the relationship between the primary health care (PHC) practice models and the used types of devices. We point at further development directions of GP practices regarding the utilization of evidence-based medical technologies and how such devices support the screening and chronic care of patients with NCDs in everyday practice. METHODS Data were collected using an online self-assessment questionnaire from 1800 Hungarian GPs registered in Hungary. Descriptive statistics, Wilcoxon's test and χ2 test were applied to analyze the ownership and utilization of 32 types of medical devices, characteristics of the GP practices and to highlight the differences between traditional and cluster-based operating model. FINDINGS Based on the responses from 27.7% of all Hungarian GPs, the medical device infrastructure was found to be limited especially in single GP-practices. Those involved in development projects of GP's clusters in the last decade reported a wider range and significantly more intensive utilization of evidence-based technologies (average number of devices: 5.42 versus 7.56, P<.001), but even these GPs are not using some of their devices (e.g., various point of care testing devices) due to the lack of financing. In addition, GPs involved in GPs-cluster development model programmes showed significantly greater willingness for sharing relatively expensive, extra workforce-demanding technologies (χ2 = 24.5, P<.001).
Collapse
|
247
|
Gatica-Ortega ME, Mowitz M, Pastor-Nieto MA, Navarro-Triviño FJ, Fernández-Redondo V, Hernández-Cano N, Borrego L, Gómez-de-la-Fuente E, Torralba M, Svedman C, Giménez-Arnau A. Contact Dermatitis From Glucose Sensors In Spain: A Multicentric Approach. Contact Dermatitis 2021; 85:554-562. [PMID: 34185891 DOI: 10.1111/cod.13924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 06/06/2021] [Accepted: 06/27/2021] [Indexed: 12/01/2022]
Abstract
BACKGROUND Allergic contact dermatitis from glucose sensors may interfere with their ongoing application. OBJECTIVE To evaluate a series of Spanish patients with contact dermatitis to glucose sensors regarding former sources of contact allergens, patch test results and outcomes from the ongoing use of the device. METHODS A series of patients with contact dermatitis from glucose sensors was investigated in eight dermatology departments across Spain epidemiologic features, brands, latency time to develop dermatitis, the ability to continue using the devices as well as the patch test results. RESULTS Thirty patients were evaluated mean age: 20 .93 years. 66 .7 % were children and 66 .7 % female. 90 .0 % used Freestyle Libre FSL. 8 /26 30 .8 % reacted to isobornyl acrylate IBOA and 2 /20 10 .0 % to N,N dimethylacrylamide DMAA. The mean latency time to develop dermatitis was 9 months. 16 /29 55 .2 % patients continued using the same sensor causing the reaction. 13 /29 44 .8 % were unable to continue using the sensor due to severe reactions. Of them, 5 were positive to IBOA, one to IBOA and DMAA; one to DMAA; one to colophony and 1 to isopropyl alcohol wipes. In one patient the outcome was unknown. CONCLUSION The frequency of sensitization to IBOA and DMAA, was lower than in other European series, but similar to a previously published Spanish article. Legislation requiring manufacturers to provide information regarding medical devices composition and cooperate with the investigation of contact dermatitis is urgently needed. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
| | - Martin Mowitz
- Dept. of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - María A Pastor-Nieto
- Dermatology Dept. Hospital Universitario de Guadalajara Guadalajara, Spain.,Dept. of Medicine and Medical Specialties, Faculty of Medicine and Health Sciences, Faculty of Medicine, Alcalá University Alcalá de Henares, Madrid, Spain
| | | | | | | | - Leopoldo Borrego
- Universidad de Las Palmas de Gran Canaria. Dermatology Dept. Hospital Universitario Insular Dermatology Dept. Hospital Universitario Insular
| | | | - Miguel Torralba
- Dept. of Medicine and Medical Specialties, Faculty of Medicine and Health Sciences, Faculty of Medicine, Alcalá University Alcalá de Henares, Madrid, Spain.,Internal Medicine Dept., University Hospital of Guadalajara, Spain
| | - Cecilia Svedman
- Dept. of Occupational and Environmental Dermatology, Lund University, Skåne University Hospital, Malmö, Sweden
| | - Ana Giménez-Arnau
- Dermatology Dept. Hospital del Mar, IMIM, Universitat Autònoma de Barcelona
| |
Collapse
|
248
|
Abstract
Additive Manufacturing (AM) capabilities in terms of product customization, manufacture of complex shape, minimal time, and low volume production those are very well suited for medical implants and biological models. AM technology permits the fabrication of physical object based on the 3D CAD model through layer by layer manufacturing method. AM use Magnetic Resonance Image (MRI), Computed Tomography (CT), and 3D scanning images and these data are converted into surface tessellation language (STL) file for fabrication. The applications of AM in ophthalmology includes diagnosis and treatment planning, customized prosthesis, implants, surgical practice/simulation, pre-operative surgical planning, fabrication of assistive tools, surgical tools, and instruments. In this article, development of AM technology in ophthalmology and its potential applications is reviewed. The aim of this study is nurturing an awareness of the engineers and ophthalmologists to enhance the ophthalmic devices and instruments. Here some of the 3D printed case examples of functional prototype and concept prototypes are carried out to understand the capabilities of this technology. This research paper explores the possibility of AM technology that can be successfully executed in the ophthalmology field for developing innovative products. This novel technique is used toward improving the quality of treatment and surgical skills by customization and pre-operative treatment planning which are more promising factors.
Collapse
Affiliation(s)
- Arivazhagan Pugalendhi
- Department of Mechanical Engineering, Coimbatore Institute of Technology, Coimbatore, Tamil Nadu, India
| | - Rajesh Ranganathan
- Department of Mechanical Engineering, Coimbatore Institute of Technology, Coimbatore, Tamil Nadu, India
| |
Collapse
|
249
|
Pérez Davila S, González Rodríguez L, Chiussi S, Serra J, González P. How to Sterilize Polylactic Acid Based Medical Devices? Polymers (Basel) 2021; 13:2115. [PMID: 34203204 DOI: 10.3390/polym13132115] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Revised: 06/18/2021] [Accepted: 06/23/2021] [Indexed: 12/24/2022] Open
Abstract
How sterilization techniques accurately affect the properties of biopolymers continues to be an issue of discussion in the field of biomedical engineering, particularly now with the development of 3D-printed devices. One of the most widely used biopolymers in the manufacture of biomedical devices is the polylactic acid (PLA). Despite the large number of studies found in the literature on PLA devices, relatively few papers focus on the effects of sterilization treatments on its properties. It is well documented in the literature that conventional sterilization techniques, such as heat, gamma irradiation and ethylene oxide, can induced damages, alterations or toxic products release, due to the thermal and hydrolytical sensitivity of PLA. The purposes of this paper are, therefore, to review the published data on the most common techniques used to sterilize PLA medical devices and to analyse how they are affecting their physicochemical and biocompatible properties. Emerging and alternative sterilization methods for sensitive biomaterials are also presented.
Collapse
|
250
|
Bell C, Mohedas I, Soyars C, Sienko KH. Preliminary clinical assessment of a task-shifting device for subcutaneous contraceptive implants. Int J Gynaecol Obstet 2021; 155:159-161. [PMID: 34143452 DOI: 10.1002/ijgo.13791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 05/04/2021] [Accepted: 06/17/2021] [Indexed: 11/06/2022]
Affiliation(s)
- Carrie Bell
- Department of Obstetrics and Gynecology, University of Michigan, Ann Arbor, MI, USA
| | - Ibrahim Mohedas
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Caroline Soyars
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| | - Kathleen H Sienko
- Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan, USA
| |
Collapse
|