1
|
Alqahtani SM, Chaturvedi S, Alkhurays M, Al Mansoori MA, Mehta V, Chaturvedi M. Clinical effectiveness of Zirconia versus titanium dental implants in anterior region: an overview of systematic reviews. Eur J Med Res 2025; 30:290. [PMID: 40235013 PMCID: PMC12001583 DOI: 10.1186/s40001-025-02488-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2024] [Accepted: 03/20/2025] [Indexed: 04/17/2025] Open
Abstract
BACKGROUND Nowadays dental implants are commonly used and to fulfil esthetic demands, zirconia has been suggested as an implant material as an alternative to titanium. Many researchers and systematic reviews are documented on it, but the results have been often inconsistent. This overview of systematic reviews aimed to report on the factors that influence the clinical effectiveness of zirconia (Zi) versus titanium (Ti) dental implants in anterior region. METHODS This overview of systematic reviews (Registration Number CRD42023396206) is in accordance with the Transparent Reporting of Systematic Reviews and Meta-analyses. PubMed, Cochrane, Scopus, Embase and Google Scholar databases were sourced for systematic review and meta-analyses. Joanna Briggs Institute (JBI) criteria and Measurement Tool to Assess systematic Reviews" (AMSTAR-2), evaluated the quality. The PICO-focused question of this overview of systematic reviews was "What are the various factors influencing the clinical performance of Zi versus Ti implants in the anterior area?", Evaluations were assessed by two assessors. In case there was any uncertainty or dispute among the reviewers, the work was included for further screening. Using Cohen's kappa, the inter-reviewer reliability was evaluated. RESULTS Six reviews were chosen from 57 suitable reviews for this data analysis. Although the survival and effectiveness rates backed titanium implants, there was no conclusive proof of marginal bone loss. Zirconium implants performed better in terms of aesthetics. CONCLUSION Clinical performance of zirconia could be considered at par with titanium implants in the anterior area. Titanium has exhibited greater mechanical performance but no significant difference between two recorded. In future, studies with improved design are needed to identify biological and technical factors that affect implant's efficacy. NOVELTY AND RELEVANCE This is the first overview of systematic reviews focusing specifically on the anterior region, evaluates both aesthetic and biomechanical performance of Zi and Ti Implants, offers detailed insight into material-specific advantages and limitations. In the present clinical scenario it addresses a critical gap by comparing the performance of Zi and Ti implants and evaluates patient-centred priorities, particularly in the highly visible anterior region.
Collapse
Affiliation(s)
- Saeed M Alqahtani
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, 62529, Abha, Saudi Arabia
| | - Saurabh Chaturvedi
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, 62529, Abha, Saudi Arabia.
- Department of Prosthetic Dentistry, SPDC, DMIHER (DU), Wardha, Maharashtra, 422001, India.
| | - Mohammed Alkhurays
- Department of Prosthetic Dental Sciences, Ministry of Health, Abha Dental Speciality Centre, Abha, Saudi Arabia
| | | | - Vini Mehta
- Department of Dental Research Cell, Dr. D. Y. Patil Dental College and Hospital, Dr. D. Y. Patil Vidyapeeth, Pimpri, Pune, 411018, India
| | - Mudita Chaturvedi
- Department of Dental Research Cell, Dr. D. Y. Patil Dental College and Hospital, Dr. D. Y. Patil Vidyapeeth, Pimpri, Pune, 411018, India
| |
Collapse
|
2
|
El-Bahy SM, Amin AS, El-Sayed R, Debbabi KF, Hassan N, Aish M. Utilization of non-plasticized polymer inclusion membrane for highly selective colorimetric sensor detection of zirconium in environmental samples. RSC Adv 2025; 15:5462-5475. [PMID: 39967881 PMCID: PMC11833446 DOI: 10.1039/d4ra05674d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2024] [Accepted: 12/20/2024] [Indexed: 02/20/2025] Open
Abstract
A pioneering colorimetric optical sensing system utilizing polymer inclusion membranes (PIM) devoid of plasticizers has been innovated for the discerning identification of zirconium(iv) within environmental specimens, characterized by its simplicity, speed, selectivity, and sensitivity. The assembly of this optical sensor relies on a physical immobilization technique, specifically the encapsulation method, which leads to the creation of the sensor membrane. The key components of the PIM sensor include 5-(2-benzothiazolylazo)-8-hydroxyquinolene (BTAHQ) as the reagent, polyvinyl chloride (PVC) serving as the base polymer, and Aliquat 336 functioning as an extractant. Empirical studies reveal that the responsiveness of the optical sensor is significantly affected by diverse parameters including the presence of PVC as the base polymer, thickness of the film, concentrations of BTAHQ and Aliquat 336, temperature, stirring conditions, and the pH level of the aqueous solution. Optimization endeavors have resulted in characterizing the sensor, establishing a linear dynamic range from 4.0 to 110 ng mL-1 for Zr(iv), showcasing quantification and detection limits of 3.95 and 1.20 ng mL-1, respectively. The sensor demonstrates a swift response time of absorbance for the PIM-based sensor which is observed at λ max 622 nm. Furthermore, the advanced PIM formulation exhibits stability, and retains its sensitivity, selectivity, and reusability. The method has been successfully applied to determine zirconium in real environmental samples, encompassing soil, water, plant materials, and ore samples.
Collapse
Affiliation(s)
- Salah M El-Bahy
- Department of Chemistry, Turabah University College, Taif University Taif Saudi Arabia
| | - Alaa S Amin
- Chemistry Department, Faculty of Science, Benha University Benha Egypt
| | - Refat El-Sayed
- Chemistry Department, Faculty of Science, Benha University Benha Egypt
- Department of Chemistry, University College in Al-Jamoum, Umm Al-Qura University 21955 Makkah Saudi Arabia
| | - Khaled F Debbabi
- Department of Chemistry, University College in Al-Jamoum, Umm Al-Qura University 21955 Makkah Saudi Arabia
- Department of Chemistry, Higher Institute of Applied Sciences & Technology of Mahdia, University of Monastir Tunisia
| | - Nader Hassan
- Chemistry Department, Faculty of Science, Port Said University Port Said Egypt
| | - Mai Aish
- Chemistry Department, Faculty of Science, Port Said University Port Said Egypt
| |
Collapse
|
3
|
Rushinek H, Cohen A, Casap N, Alterman M. The Effect of Implant-Associated Factors on the Long-Term Outcomes of Dental Implants. Oral Maxillofac Surg Clin North Am 2025; 37:51-63. [PMID: 39384509 DOI: 10.1016/j.coms.2024.08.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/11/2024]
Abstract
The long-term outcomes of dental implants are influenced by a variety of factors, all of which play critical roles in their stability, functionality, and esthetic appeal. This review focuses on several key characteristics of dental implants that impact their success overtime: dimensional, morphologic, material, osseointegrative, and connective/prosthetic characteristics. This article synthesizes current literature to analyze how these factors influence the long-term success of dental implants, emphasizing the need for a comprehensive approach in implant selection and placement.
Collapse
Affiliation(s)
- Heli Rushinek
- Faculty of Dental Medicine, Hebrew University of Jerusalem, PO Box 12272, Jerusalem 9112102, Israel; Department of Oral and Maxillofacial Surgery, Hadassah Medical Center, Jerusalem, Israel
| | - Adir Cohen
- Faculty of Dental Medicine, Hebrew University of Jerusalem, PO Box 12272, Jerusalem 9112102, Israel; Department of Oral and Maxillofacial Surgery, Hadassah Medical Center, Jerusalem, Israel
| | - Nardy Casap
- Faculty of Dental Medicine, Hebrew University of Jerusalem, PO Box 12272, Jerusalem 9112102, Israel; Department of Oral and Maxillofacial Surgery, Hadassah Medical Center, Jerusalem, Israel
| | - Michael Alterman
- Faculty of Dental Medicine, Hebrew University of Jerusalem, PO Box 12272, Jerusalem 9112102, Israel; Department of Oral and Maxillofacial Surgery, Hadassah Medical Center, Jerusalem, Israel.
| |
Collapse
|
4
|
Gao Y, He X, Xu W, Deng Y, Xia Z, Chen J, He Y. Three-dimensional finite element analysis of the biomechanical properties of different material implants for replacing missing teeth. Odontology 2025; 113:80-88. [PMID: 38717525 DOI: 10.1007/s10266-024-00942-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2023] [Accepted: 04/17/2024] [Indexed: 01/11/2025]
Abstract
The purpose of this study was to analyze the biomechanical properties of implants made of different materials to replace missing teeth by using three-dimensional finite element analysis and provide a theoretic basis for clinical application. CBCT data was imported into the Mimics and 3-Matic to construct the three-dimensional finite element model of a missing tooth restored by an implant. Then, the model was imported into the Marc Mentat. Based on the variations of the implant materials (titanium, titanium-zirconia, zirconia and poly (ether-ether-ketone) (PEEK)) and bone densities (high and low), a total of eight models were created. An axial load of 150 N was applied to the crown of the implant to simulate the actual occlusal situation. Both the maximum values of stresses in the cortical bone and implant were observed in the Zr-low model. The maximum displacements of the implants were also within the normal range except for the PEEK models. The cancellous bone strains were mainly distributed in the apical area of the implant, and the maximum value (3225 μstrain) was found in PEEK-low model. Under the premise of the same implant material, the relevant data from various indices in low-density bone models were larger than that in high-density bone models. From the biomechanical point of view, zirconia, titanium and titanium-zirconia were all acceptable implant materials for replacing missing teeth and possessed excellent mechanical properties, while the application of PEEK material needs to be further optimized and modified.
Collapse
Affiliation(s)
- Yichen Gao
- Department of Oral and Maxillofacial Surgery, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China
- Oral & Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China
| | - Xianyi He
- Department of Oral and Maxillofacial Surgery, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China
- Oral & Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China
| | - Wei Xu
- Department of Oral and Maxillofacial Surgery, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China
- Oral & Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China
| | - Yuyao Deng
- Department of Oral and Maxillofacial Surgery, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China
- Oral & Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China
| | - Zhaoxin Xia
- Department of Oral and Maxillofacial Surgery, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China
- Oral & Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China
| | - Junliang Chen
- Department of Oral and Maxillofacial Surgery, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China
- Oral & Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China
| | - Yun He
- Department of Oral and Maxillofacial Surgery, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China.
- Oral & Maxillofacial Reconstruction and Regeneration of Luzhou Key Laboratory, The Affiliated Stomatological Hospital of Southwest Medical University, Luzhou, 646000, China.
| |
Collapse
|
5
|
Thangavelu L, Parthasarathy PR, Tharmar MAA. Ceramic Biomaterials in Dental Implantology—Time for Change of Status Quo: An Updated Review. WORLD JOURNAL OF DENTISTRY 2024; 15:733-742. [DOI: 10.5005/jp-journals-10015-2471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
|
6
|
Newman A, Anderson NK, Romanos GE. Bovine Mineral Grafting Affects the Hydrophilicity of Dental Implant Surfaces: An In Vitro Study. MATERIALS (BASEL, SWITZERLAND) 2024; 17:4052. [PMID: 39203230 PMCID: PMC11356546 DOI: 10.3390/ma17164052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/20/2024] [Revised: 08/05/2024] [Accepted: 08/09/2024] [Indexed: 09/03/2024]
Abstract
Wettability is recognized as an important property of implant surfaces for ensuring improved biological responses. However, limited information exists on how bone grafting procedures including materials influence the hydrophilic behavior of implant surfaces. This in vitro study aimed to investigate the influence of two bovine grafting materials after hydration on the wettability of four different disk surfaces: commercially pure titanium (CP-Ti), titanium-zirconium dioxide (TiZrO2-Cerid®), zirconia (SDS®), and niobium. Wettability tests were performed on each of the four implant surfaces with a solution of 0.9% sodium chloride after mixture with W-boneTM (Group A) or Bio-Oss® (Group B) or 0.9% sodium chloride alone (Group C). In total, 360 contact angle measurements were completed with n = 30 per group. Statistical analysis was performed using a one-way analysis with variance (ANOVA) test with a significant mean difference at the 0.05 level. For pure titanium, Group A demonstrated increased hydrophilicity compared to Group B. Both TiZrO2 and zirconia showed significant differences for Groups A, B and C, exhibiting a decrease in hydrophilicity after the use of bovine grafting materials compared to titanium surfaces. Niobium remained consistently hydrophobic. In summary, this study revealed that bovine grafting materials may diminish the hydrophilicity of zirconia surfaces and exert varied effects on titanium and niobium. These findings contribute to the understanding of implant surface interactions with grafting materials, offering insights for optimizing biological responses in implantology.
Collapse
Affiliation(s)
- Allyson Newman
- Laboratory of Periodontal, Implant-, Phototherapy, Department of Periodontics and Endodontics, Stony Brook University, Stony Brook, NY 11794, USA;
| | - Nina K. Anderson
- Department of Oral Biology and Pathology, Stony Brook University, Stony Brook, NY 11794, USA;
| | - Georgios E. Romanos
- Laboratory of Periodontal, Implant-, Phototherapy, Department of Periodontics and Endodontics, Stony Brook University, Stony Brook, NY 11794, USA;
| |
Collapse
|
7
|
Morena D, Leitão-Almeida B, Pereira M, Resende R, Fernandes JCH, Fernandes GVO, Borges T. Comparative Clinical Behavior of Zirconia versus Titanium Dental Implants: A Systematic Review and Meta-Analysis of Randomized Controlled Trials. J Clin Med 2024; 13:4488. [PMID: 39124755 PMCID: PMC11313197 DOI: 10.3390/jcm13154488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2024] [Revised: 07/26/2024] [Accepted: 07/29/2024] [Indexed: 08/12/2024] Open
Abstract
Objective: The goal of this systematic review and meta-analysis was to assess whether there were clinically relevant differences in the treatment of edentulous areas comparing zirconia (Zr) and titanium (Ti) dental implants. The null hypothesis is that no differences can be observed in terms of the clinical parameters; the positive hypothesis I is that Zr implants have generally better results compared to Ti implants; and the positive hypothesis II is that Ti implants have a generally superior result than Zr implants. Methods: This review work was registered on the PROSPERO platform, and its development was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement. The electronic search process was conducted on three databases (PubMed/Scopus/Web of Science), including randomized controlled trials (RCTs) from the past 10 years (up to April 2024). Identified articles were analyzed and included/excluded based on pre-defined selection and exclusion criteria. The quality assessment and risk of bias were evaluated using a Cochrane risk-of-bias assessment tool specifically designed for randomized trials (RoB2). A meta-analysis was conducted to correlate different treatment options based on the described outcomes; a random-effects model was used in the analysis of the variables. The analysis of heterogeneity was conducted by means of Cochran's Q-test and Higgins' I2 statistic. Results: Six RCTs were enrolled; 152 patients (90 males and 62 females) and 448 implants (267 Zr and 181 Ti) were included. Dental implant placement involved both the maxillary and mandibular arches. The implant sites showed heterogeneity in receiving Zr and Ti dental implants; in particular, 22 dental implants were placed in the mid-palatal region and 426 dental implants in the alveolar region (255 were in Zr and 171 in Ti). Regarding the success rate, it was better for Zr but with no statistical difference (p > 0.05); bleeding on probing had slight differences between Ti with 0.34% ± 0.42 and Zr with 0.26% ± 0.36 (p > 0.05); plaque score showed 0.46 ± 0.47 for Ti compared to 0.44 ± 0.49 for Zr (p > 0.05); no statistically significant difference was observed for pink esthetic score (PES). Statistically significant results were found for survival rate, which favored Ti implants (77.6%) compared to Zr (70.3%) (p < 0.05), and for marginal bone loss, which showed less loss in Ti implants (0.18 mm ± 0.47) compared to 0.42 mm ± 0.40 in Zr at 12 months (p < 0.001). Conclusions: The present systematic review and meta-analysis identified the positive hypothesis I and rejected the null and positive hypothesis II; it was possible to conclude that Ti dental implants have a better survival rate and less marginal bone loss than Zr dental implants after 1-year follow-up.
Collapse
Affiliation(s)
- Danilo Morena
- Faculty of Dental Medicine, Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
| | - Bruno Leitão-Almeida
- Faculty of Dental Medicine, Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
- Centre for Interdisciplinary Research in Health (CIIS), Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
| | - Miguel Pereira
- Faculty of Dental Medicine, Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
- Centre for Interdisciplinary Research in Health (CIIS), Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
| | - Rodrigo Resende
- Faculty of Dentistry, Fluminense Federal University, Niterói, RJ 24220-140, Brazil
| | | | - Gustavo Vicentis Oliveira Fernandes
- Centre for Interdisciplinary Research in Health (CIIS), Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
- Missouri School of Dentistry and Oral Health, A. T. Still University, St. Louis, MO 63104, USA
| | - Tiago Borges
- Faculty of Dental Medicine, Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
- Centre for Interdisciplinary Research in Health (CIIS), Universidade Católica Portuguesa, 3504-505 Viseu, Portugal
| |
Collapse
|
8
|
da Silva AMP, Horta Dos Santos FA, Mota RF, Teixeira MKS, Telles DM, Lourenço EJV. Clinical and radiographic outcomes of a two-piece ceramic implant: one year results from a prospective clinical trial. Clin Oral Investig 2024; 28:380. [PMID: 38886209 DOI: 10.1007/s00784-024-05783-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Accepted: 06/11/2024] [Indexed: 06/20/2024]
Abstract
OBJECTIVE To describe the clinical and radiographic performance and survival rate of a new two-piece ceramic implant system after at least 12 months of follow-up. MATERIALS AND METHODS Sixty-five implants were placed and followed up for at least 12 months (12.3 ± 1.5), in 50 patients. The implants were installed both in fresh extraction sockets and in healed sites and received provisional restoration when the clinical insertion torque was greater than 35Ncm. The primary results describe the survival rate of these implants. Clinical performance was evaluated through the evaluation of the Pink Esthetic Score (PES) and the degree of satisfaction of the patients. Bone loss was measured through radiographic measurements of the marginal bone loss in the mesial (MBLM) and distal (MBLD) sites. RESULTS The survival rate was 98.5%. The average MBLM was 0.24 mm (± 0.53) and the MBLD was 0.27 mm (± 0.57). A statistical difference was observed only when comparing immediate implants with delayed ones (MBLM - p = 0.046 and MBLD - p = 0.028) and when they received immediate provisionalization or not (MBLM - p = 0.009 and MBLD - p = 0.040). The PES before the intervention (T0) was 13.4 (± 0.8) and the PES at T2 (12-month follow-up) was 12.9 (± 1.5) (p = 1.14). CONCLUSION The new two-piece ceramic implant used in the present study showed predictable and reliable results, similar to those found with titanium implants after one year of follow-up. CLINICAL RELEVANCE These implants can be used as an alternative to titanium implants in terms of the marginal bone loss and the degree of patient satisfaction.
Collapse
Affiliation(s)
- Alexandre Marques Paes da Silva
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil
| | | | - Rodrigo Franco Mota
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil
| | - Mayla Kezy Silva Teixeira
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil.
| | - Daniel Moraes Telles
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil
| | - Eduardo José Veras Lourenço
- Department of Prosthodontics, Faculty of Odontology, Rio de Janeiro State University, Boulevard 28 de Setembro 157, 2o Andar, Vila Isabel, Rio de Janeiro, RJ, 20551-030, Brazil
| |
Collapse
|
9
|
Padhye NM, Calciolari E, Zuercher AN, Tagliaferri S, Donos N. Survival and success of zirconia compared with titanium implants: a systematic review and meta-analysis. Clin Oral Investig 2023; 27:6279-6290. [PMID: 37740825 PMCID: PMC10630218 DOI: 10.1007/s00784-023-05242-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Accepted: 09/05/2023] [Indexed: 09/25/2023]
Abstract
OBJECTIVE This systematic review assessed the available evidence on the survival and success rate of zirconia and titanium implants. As secondary outcomes, aesthetic, radiographic and clinical parameters, as well as biological and mechanical complications, were considered. MATERIALS AND METHODS A systematic search was performed up to March 2022 to identify CCTs/RCTs comparing zirconia and titanium implants with a minimum of 12 months of follow-up. Meta-analysis was performed when ≥ 2 articles with similar characteristics were retrieved. RESULTS Four published articles with two RCTs (2 different patient populations) with 100 zirconia and 99 titanium implants that were followed up over 12-80 months were selected out of the 6040 articles. A non-statistically significant difference between zirconia and titanium implant survival at 12 months was suggested (P = 0.0938). The success rates were 57.5-93.3% and 57.1-100% for zirconia and titanium implants, respectively. The pink aesthetic score (PES) was higher for zirconia (10.33 ± 2.06 to 11.38 ± 0.92) compared to titanium implants (8.14 ± 3.58 to 11.56 ± 1.0). CONCLUSION Based on the 2 RCTs retrieved in the literature, similar survival rates were reported for zirconia and titanium implants in the short term (12 months of follow-up). Future RCTs are warranted to evaluate the long-term outcomes of zirconia implants. CLINICAL RELEVANCE Zirconia implants may be the procedure of choice, particularly in the aesthetic zone, since they show a similar survival and success rate as titanium implants on a short-term follow-up. TRIAL REGISTRATION Systematic review registration number-CRD42021288704 (PROSPERO).
Collapse
Affiliation(s)
- Ninad Milind Padhye
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
| | - Elena Calciolari
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
- Department of Medicine and Surgery, Centre of Dentistry, University of Parma, Parma, Italy
| | - Anina Nives Zuercher
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK
- Clinic of Reconstructive Dentistry, Centre of Dental Medicine, Zurich, Switzerland
| | - Sara Tagliaferri
- Department of Medicine and Surgery, University of Parma, Parma, Italy
- Center of Excellence for Toxicological Research, CERT, University of Parma, Parma, Italy
| | - Nikos Donos
- Centre for Oral Clinical Research, Institute of Dentistry, Faculty of Medicine and Dentistry, Queen Mary University of London (QMUL), London, UK.
| |
Collapse
|
10
|
Nueesch R, Karlin S, Fischer J, Rohr N. In Vitro Investigation of Material Combinations for Meso- and Suprastructures in a Biomimetic Approach to Restore One-Piece Zirconia Implants. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1355. [PMID: 36836985 PMCID: PMC9960926 DOI: 10.3390/ma16041355] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 01/30/2023] [Accepted: 02/01/2023] [Indexed: 06/18/2023]
Abstract
The aim of this study was to find a suitable material combination to avoid cement excess in the marginal region of one-piece zirconia implant-supported restorations by means of a hybrid crown consisting of a meso- and a suprastructure. One-piece zirconia implants (n = 120) were embedded in epoxy resin. Microfilled resin composite mesostructures (n = 60), designed as caps, were bonded on the implant abutment with a primer only. A molar crown was constructed and cemented with a resin cement on top of the mesostructure as a suprastructure out of feldspar ceramic (n = 12), lithium-disilicate (n = 24), or zirconia (n = 24). Fracture load (n = 6) and retention force (n = 6) were measured immediately after storage in distilled water at 37 °C for 24 h, as well as after an additional exposure to artificial aging in a chewing simulator and simultaneous thermal cycling. For the measurement of the fracture load, monolithic crowns made of the employed restorative materials and identical in shape to the hybrid crowns served as controls (n = 6 each). Fracture load values for feldspar ceramic and lithium-disilicate hybrid crowns were slightly higher than those for the respective monolithic crowns at baseline and after aging, which was statistically significant only for feldspar crowns after aging. In contrast, fracture load values for zirconia monolithic crowns were higher than those for zirconia hybrid crowns, which was only statistically significant after aging. Artificial aging reduced the fracture load of feldspar and lithium-disilicate crowns both for hybrid and monolithic crowns. The effect was only statistically significant for lithium disilicate hybrid crowns. The fracture load for hybrid and monolithic zirconia crowns was increased by artificial aging without reaching statistical significance. The retention force of lithium-disilicate and zirconia hybrid crowns was not affected by artificial aging. Taking into account retention force and fracture load, lithium-disilicate hybrid crowns showed promising results.
Collapse
|
11
|
Thangavel M, Elsen Selvam R. Review of Physical, Mechanical, and Biological Characteristics of 3D-Printed Bioceramic Scaffolds for Bone Tissue Engineering Applications. ACS Biomater Sci Eng 2022; 8:5060-5093. [PMID: 36415173 DOI: 10.1021/acsbiomaterials.2c00793] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
This review focuses on the advancements in additive manufacturing techniques that are utilized for fabricating bioceramic scaffolds and their characterizations leading to bone tissue regeneration. Bioscaffolds are made by mimicking the human bone structure, material composition, and properties. Calcium phosphate apatite materials are the most commonly used scaffold materials as they closely resemble live bone in their inorganic composition. The functionally graded scaffolds are fabricated by utilizing the right choice of the 3D printing method and material combinations to achieve the requirement of the bioscaffold. To tailor the physical, mechanical, and biological properties of the scaffold, certain materials are reinforced, doped, or coated to incorporate the functionality. The biomechanical loading conditions that involve flexion, torsion, and tension exerted on the implanted scaffold are discussed. The finite element analysis (FEA) technique is used to investigate the mechanical property of the scaffold before fabrication. This helps in reducing the actual number of samples used for testing. The FEA simulated results and the experimental result are compared. This review also highlights some of the challenges associated while processing the scaffold such as shrinkage, mechanical instability, cytotoxicity, and printability. In the end, the new materials that are evolved for tissue engineering applications are compiled and discussed.
Collapse
Affiliation(s)
- Mahendran Thangavel
- School of Mechanical Engineering, Vellore Institute of Technology, Vellore, Tamil Nadu 632014, India
| | - Renold Elsen Selvam
- School of Mechanical Engineering, Vellore Institute of Technology, Vellore, Tamil Nadu 632014, India
| |
Collapse
|
12
|
Rutkowski R, Smeets R, Neuhöffer L, Stolzer C, Strick K, Gosau M, Sehner S, Volz KU, Henningsen A. Success and patient satisfaction of immediately loaded zirconia implants with fixed restorations one year after loading. BMC Oral Health 2022; 22:198. [PMID: 35606734 PMCID: PMC9125844 DOI: 10.1186/s12903-022-02231-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Accepted: 04/25/2022] [Indexed: 11/27/2022] Open
Abstract
Background There is limited evidence for the use of zirconium dioxide implants in immediate implant placement as well as for related immediate loading protocols. The aim of this retrospective study was to investigate the survival rate, success and patient satisfaction of immediately placed zirconia implants compared to delayed placed implants. Methods The study included 58 partially edentulous patients who were treated between 2013 and 2015 with immediate and delayed transgingival healing zirconium dioxide implants (SDS, Kreuzlingen/ Switzerland). In addition to survival and success rate, marginal bone loss was assessed using radiographs and soft tissue was evaluated using Pink Esthetic Score. Oral health-related quality of life was investigated prospectively using a modified OHIP questionnaire. Results The cumulative survival rate of all implants included was 92% with 88% classified as full success. No significant difference was found between the bone levels of immediately and delayed placed and immediately and delayed loaded implants. The mean Pink Esthetic Score after final prosthetic rehabilitation was 12.2/14 points indicating excellent esthetic clinical results. Analysis of the OHIP questionnaire showed a mean value of 0.54/100 points reflecting a high patient satisfaction. Conclusions Immediate and delayed placed as well as loaded zirconium dioxide implants showed excellent results regarding implant success and survival in this study. Zirconium dioxide implants may ensure excellent esthetic results and high patient satisfaction. Supplementary Information The online version contains supplementary material available at 10.1186/s12903-022-02231-0.
Collapse
Affiliation(s)
- Rico Rutkowski
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Ralf Smeets
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.,Division Regenerative Orofacial Medicine, Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Leon Neuhöffer
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Carolin Stolzer
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Kilian Strick
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Martin Gosau
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany
| | - Susanne Sehner
- Department of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | | | - Anders Henningsen
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany. .,Division Regenerative Orofacial Medicine, Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
| |
Collapse
|
13
|
Clinical and Radiographic Outcomes of Zirconia Dental Implants-A Clinical Case Series Study. MATERIALS 2022; 15:ma15072437. [PMID: 35407772 PMCID: PMC8999721 DOI: 10.3390/ma15072437] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Revised: 03/22/2022] [Accepted: 03/23/2022] [Indexed: 11/17/2022]
Abstract
The purpose of this clinical series was to evaluate the clinical and radiographic outcomes of 20 zirconia dental implants, with a minimum follow-up of two years. Patients with at least one zirconia dental implant were included, with a mean follow-up of 34.05 months. The patient complaints such as pain and foreign body sensation, as well as clinical parameters including peri-implant infections with suppuration, implant mobility, gingival index (GI), modified plaque index (mPI), modified sulcus bleeding index (mBI), probing depth (PD) and radiological distance between the implant shoulder to the closest mesial and distal bone-to-implant contact (BIC), were assessed. All zirconia implants were successfully integrated without any pain or foreign body sensation. No mobility was detected in any of the 20 implants. Clinical examination revealed a mean PD of 2.56 mm and a radiological mean distance between the implant shoulder and the initial site of visible bone-to-implant contact (BIC) of 1.44 mm. In addition, GI, mPI and mBI indicated minimal to no inflammation. Results obtained from this series suggest that one-piece zirconia dental implants achieve good clinical and radiographic outcomes over a mean follow-up of 34 months and may be deemed a good option in patients with favorable bone conditions.
Collapse
|
14
|
Choi SM, Choi H, Lee DH, Hong MH. Comparative finite element analysis of mandibular posterior single zirconia and titanium implants: a 3-dimensional finite element analysis. J Adv Prosthodont 2022; 13:396-407. [PMID: 35003555 PMCID: PMC8712109 DOI: 10.4047/jap.2021.13.6.396] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 11/23/2021] [Accepted: 12/06/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Zirconia has exceptional biocompatibility and good mechanical properties in clinical situations. However, finite element analysis (FEA) studies on the biomechanical stability of two-piece zirconia implant systems are limited. Therefore, the aim of this study was to compare the biomechanical properties of the two-piece zirconia and titanium implants using FEA. MATERIALS AND METHODS Two groups of finite element (FE) models, the zirconia (Zircon) and titanium (Titan) models, were generated for the exam. Oblique (175 N) and vertical (175 N) loads were applied to the FE model generated for FEA simulation, and the stress levels and distributions were investigated. RESULTS In oblique loading, von Mises stress values were the highest in the abutment of the Zircon model. The von Mises stress values of the Titan model for the abutment screw and implant fixture were slightly higher than those of the Zircon model. Minimum principal stress in the cortical bone was higher in the Titan model than Zircon model under oblique and vertical loading. Under both vertical and oblique loads, stress concentrations in the implant components and bone occurred in the same area. Because the material itself has high stiffness and elastic modulus, the Zircon model exhibited a higher von Mises stress value in the abutments than the Titan model, but at a level lower than the fracture strength of the material. CONCLUSION Owing to the good esthetics and stress controllability of the Zircon model, it can be considered for clinical use.
Collapse
Affiliation(s)
- Sung-Min Choi
- Department of Dental Laboratory Science, College of Health Sciences, Catholic University of Pusan, Busan, Republic of Korea
| | - Hyunsuk Choi
- Department of Dentistry and Prosthodontics, Daegu Catholic University School of Medicine, Daegu, Republic of Korea
| | - Du-Hyeong Lee
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu, Republic of Korea
| | - Min-Ho Hong
- Department of Dental Laboratory Science, College of Health Sciences, Catholic University of Pusan, Busan, Republic of Korea
| |
Collapse
|
15
|
Krautwald L, Smeets R, Stolzer C, Rutkowski R, Guo L, Reitmeier A, Gosau M, Henningsen A. Osseointegration of Zirconia Implants after UV-Light or Cold Atmospheric Plasma Surface Treatment In Vivo. MATERIALS 2022; 15:ma15020496. [PMID: 35057216 PMCID: PMC8781961 DOI: 10.3390/ma15020496] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2021] [Revised: 12/04/2021] [Accepted: 12/15/2021] [Indexed: 12/04/2022]
Abstract
The influence of UV light and non-thermal plasma on the osseointegration of yttria-stabilized zirconia implants (Y-TZP) comparing the two methods is unclear. The aim of this study was to show the influence of these methods on the osseointegration of dental zirconia implants in an animal model. A total of 54 implants were either untreated, treated with UV light (UV), or non-thermal oxygen plasma for 12 min and inserted into the parietal bones of six domestic pigs. The animals were sacrificed after a healing interval of two, four, and nine weeks. The degree of osseointegration was determined using histomorphometric determination of bone-to-implant contact values (BIC) and the bone-to-implant contact values within the retentive parts of the implants (BAFO). BIC values decreased in all groups after four weeks of healing and re-increased after nine weeks in all groups. BAFO increased significantly over time in all groups. However, there were no statistically significant differences in BIC and BAFO values between the control group and the test groups and over time. Clinical studies may follow to confirm the influence of cold plasma and UV light on the healing and survival of zirconia implants.
Collapse
Affiliation(s)
- Lisa Krautwald
- Division “Regenerative Orofacial Medicine”, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany; (L.K.); (R.S.); (L.G.); (M.G.)
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany; (C.S.); (R.R.)
| | - Ralf Smeets
- Division “Regenerative Orofacial Medicine”, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany; (L.K.); (R.S.); (L.G.); (M.G.)
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany; (C.S.); (R.R.)
| | - Carolin Stolzer
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany; (C.S.); (R.R.)
| | - Rico Rutkowski
- Department of Oral and Maxillofacial Surgery, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany; (C.S.); (R.R.)
| | - Linna Guo
- Division “Regenerative Orofacial Medicine”, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany; (L.K.); (R.S.); (L.G.); (M.G.)
- Department of Stomatology, The Second Xiangya Hospital, Central South University, Changsha 410011, China
| | - Aline Reitmeier
- Department of Laboratory Animal Science, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany;
| | - Martin Gosau
- Division “Regenerative Orofacial Medicine”, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany; (L.K.); (R.S.); (L.G.); (M.G.)
| | - Anders Henningsen
- Division “Regenerative Orofacial Medicine”, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20246 Hamburg, Germany; (L.K.); (R.S.); (L.G.); (M.G.)
- Private Practice ELBE MKG, Suelldorfer Kirchenweg 1A, 22587 Hamburg, Germany
- Correspondence:
| |
Collapse
|
16
|
Thomé G, Uhlendorf J, Vianna CP, Caldas W, Bernardes SR, Trojan LC. Clinical and radiographic success of injection-molded 2-piece zirconia implants submitted to immediate loading: A 12-month report of two cases. Clin Case Rep 2021; 9:e05118. [PMID: 34917363 PMCID: PMC8643492 DOI: 10.1002/ccr3.5118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 10/26/2021] [Accepted: 11/07/2021] [Indexed: 11/07/2022] Open
Abstract
This case report describes the treatment of two patients who presented with single edentulous sites in the region of upper premolars and were rehabilitated through the placement of injection-molded 2-piece zirconia implants and immediate single crowns. Three months after surgery, definitive prostheses were confectioned through digital workflow. Both patients were followed for 12 months during which clinical and radiographic implant success were observed, concerning implant stability, absence of peri-implantitis signs, complete implant osseointegration, good marginal bone-level maintenance, and excellent soft tissue esthetics. No biological or mechanical complications were observed within this period.
Collapse
Affiliation(s)
- Geninho Thomé
- Department of ImplantologyLatin American Institute for Research and Dental Education (ILAPEO); Scientific President of NeodentCuritibaBrazil
| | | | | | | | - Sergio Rocha Bernardes
- Department of ImplantologyLatin American Institute for Research and Dental Education (ILAPEO); Head of Global Research & Education of NeodentCuritibaBrazil
| | | |
Collapse
|
17
|
Microwave assisted sol-gel synthesis of bioactive zirconia nanoparticles – Correlation of strength and structure. J Mech Behav Biomed Mater 2020; 112:104012. [DOI: 10.1016/j.jmbbm.2020.104012] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 07/21/2020] [Accepted: 07/23/2020] [Indexed: 11/21/2022]
|
18
|
Strategies to Reduce Biofilm Formation in PEEK Materials Applied to Implant Dentistry-A Comprehensive Review. Antibiotics (Basel) 2020; 9:antibiotics9090609. [PMID: 32948018 PMCID: PMC7559429 DOI: 10.3390/antibiotics9090609] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2020] [Revised: 09/08/2020] [Accepted: 09/15/2020] [Indexed: 12/11/2022] Open
Abstract
Polyether-ether-ketone (PEEK) has emerged in Implant Dentistry with a series of short-time applications and as a promising material to substitute definitive dental implants. Several strategies have been investigated to diminish biofilm formation on the PEEK surface aiming to decrease the possibility of related infections. Therefore, a comprehensive review was carried out in order to compare PEEK with materials widely used nowadays in Implant Dentistry, such as titanium and zirconia, placing emphasis on studies investigating its ability to grant or prevent biofilm formation. Most studies failed to reveal significant antimicrobial activity in pure PEEK, while several studies described new strategies to reduce biofilm formation and bacterial colonization on this material. Those include the PEEK sulfonation process, incorporation of therapeutic and bioactive agents in PEEK matrix or on PEEK surface, PEEK coatings and incorporation of reinforcement agents, in order to produce nanocomposites or blends. The two most analyzed surface properties were contact angle and roughness, while the most studied bacteria were Escherichia coli and Staphylococcus aureus. Despite PEEK's susceptibility to biofilm formation, a great number of strategies discussed in this study were able to improve its antibiofilm and antimicrobial properties.
Collapse
|
19
|
Tharani Kumar S, Prasanna Devi S, Krithika C, Raghavan RN. Review of Metallic Biomaterials in Dental Applications. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES 2020; 12:S14-S19. [PMID: 33149425 PMCID: PMC7595562 DOI: 10.4103/jpbs.jpbs_88_20] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2020] [Accepted: 03/09/2020] [Indexed: 11/23/2022] Open
Abstract
Titanium and its alloys are mainly used in manufacturing dental implants. The fact that titanium implants are immunologically very effective, new methods are being experimented to achieve utmost success rate as a biomaterial. One fundamental indicator for clinical achievement of implant is the decision of composition decided for the implant with the objective to improve osseointegration. The main objective of this study was to explore literature on dental materials used for implants, contrast them with titanium dental implants, with the aim to improve osseointegration and mechanical quality using Ti–Ga–Si dental implant.
Collapse
Affiliation(s)
- S Tharani Kumar
- Dr. MGR Educational and Research Institute University, Chennai, Tamil Nadu, India
| | - S Prasanna Devi
- Department of Computer Science & Engineering, SRM Institute of Science & Technology, Chennai, Tamil Nadu, India
| | - Chandrasekaran Krithika
- Department of Oral Medicine, Thai Moogambigai Dental College, Dr. MGR Educational and Research Institute University, Chennai, Tamil Nadu, India
| | - R N Raghavan
- RNR Dental Clinic and Research Services, Chennai, Tamil Nadu, India
| |
Collapse
|
20
|
Munro T, Miller CM, Antunes E, Sharma D. Interactions of Osteoprogenitor Cells with a Novel Zirconia Implant Surface. J Funct Biomater 2020; 11:E50. [PMID: 32708701 PMCID: PMC7565437 DOI: 10.3390/jfb11030050] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 07/10/2020] [Accepted: 07/12/2020] [Indexed: 02/03/2023] Open
Abstract
Background: This study compared the in vitro response of a mouse pre-osteoblast cell line on a novel sandblasted zirconia surface with that of titanium. Material and Methods: The MC3T3-E1 subclone 4 osteoblast precursor cell line was cultured on either sandblasted titanium (SBCpTi) or sandblasted zirconia (SBY-TZP). The surface topography was analysed by three-dimensional laser microscopy and scanning electron microscope. The wettability of the discs was also assessed. The cellular response was quantified by assessing the morphology (day 1), proliferation (day 1, 3, 5, 7, 9), viability (day 1, 9), and migration (0, 6, 24 h) assays. Results: The sandblasting surface treatment in both titanium and zirconia increased the surface roughness by rendering a defined surface topography with titanium showing more apparent nano-topography. The wettability of the two surfaces showed no significant difference. The zirconia surface resulted in improved cellular spreading and a significantly increased rate of migration compared to titanium. However, the cellular proliferation and viability noted in our experiments were not significantly different on the zirconia and titanium surfaces. Conclusions: The novel, roughened zirconia surface elicited cellular responses comparable to, or exceeding that, of titanium. Therefore, this novel zirconia surface may be an acceptable substitute for titanium as a dental implant material.
Collapse
Affiliation(s)
- Thomas Munro
- College of Medicine and Dentistry, James Cook University, 14-88 McGregor Road, Smithfield 4878, QLD, Australia;
| | - Catherine M. Miller
- College of Public Health, Medical and Veterinary Sciences, James Cook University, 14-88 McGregor Road, Smithfield 4878, QLD, Australia;
- The Australian Institute of Tropical Health and Medicine (AITHM) James Cook University, 14-88 McGregor Road, Smithfield 4878, QLD, Australia
| | - Elsa Antunes
- College of Science & Engineering, James Cook University, 1 James Cook Drive, Douglas, Townsville 4814, QLD, Australia;
| | - Dileep Sharma
- College of Medicine and Dentistry, James Cook University, 14-88 McGregor Road, Smithfield 4878, QLD, Australia;
- The Australian Institute of Tropical Health and Medicine (AITHM) James Cook University, 14-88 McGregor Road, Smithfield 4878, QLD, Australia
| |
Collapse
|
21
|
Jodha KS, Salazar Marocho SM, Scherrer SS, Griggs JA. Fractal analysis at varying locations of clinically failed zirconia dental implants. Dent Mater 2020; 36:1052-1058. [PMID: 32487485 DOI: 10.1016/j.dental.2020.04.021] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2019] [Revised: 04/22/2020] [Accepted: 04/30/2020] [Indexed: 10/24/2022]
Abstract
OBJECTIVES Previous studies have shown that the fracture toughness of ceramics can be determined from the fractal dimensions (D) of their fracture surfaces and that the surface should be leveled to obtain an accurate D measurement. This study was to determine the effects of leveling operations and distance from the failure origin on the D values. METHODS Twelve clinically failed zirconia implants from four different manufacturers: Axis Biodental (n=7), Z-Systems (n=3), Straumann (n=1), and Swiss Dental Solutions (n=1) were obtained from one of the authors and thoroughly cleaned. Epoxy replicas were made of three locations along the crack path in the center region of each fracture surface (near origin (O), hackle (H), and near compression curl (CC)) using a light body polyvinyl siloxane impression material. Surfaces were scanned in ScanAsyst mode with a scan size of 5μm×5μm and a scan rate of 0.592Hz using the atomic force microscope. The surface scans were then leveled using 1st order flattening operation in the AFM analysis software. The height data before and after the operation were imported into a custom MathCAD script, and FRACTALS software was used to determine the D value by Minkowski Cover algorithm, which was shown previously to be the algorithm with the highest precision. A Wilcoxon signed-rank test, two-way repeated-measures ANOVA, and one-way repeated-measures ANOVA were performed as detailed below. RESULTS The data were not normally distributed (S-W p≤0.05), so a non-parametric repeated measures test (Wilcoxon signed-rank test) was selected. The median D values before and after leveling were 2.161 and 2.174, respectively. There was a significant difference before and after leveling (p<0.001). The two-way repeated-measures ANOVA showed no significant difference among the D values for different implant brands (p=0.66) and scanning locations on the fracture surface (p=0.83). After eliminating the implant brand as a factor, the data passed normality and equal variance tests (S-W p=0.88, BF p=0.15). The mean D values and standard deviations from the three locations (O, H, CC) were 2.183±0.031, 2.179±0.024, and 2.175±0.018, respectively. One-way repeated measures ANOVA showed no significant effect of scanning location (p=0.74). SIGNIFICANCE The leveling operation successfully removed the tilt without decreasing surface tortuosity, as it increased the D values significantly. The fractal dimension was the same at the three locations on the fracture surfaces. This means that hackle and compression curl regions can be used to determine fracture toughness when the failure origin has been lost.
Collapse
Affiliation(s)
- Kartikeya S Jodha
- Department of Biomedical Materials Science, University of Mississippi Medical Center, MS, USA
| | - Susana M Salazar Marocho
- University Clinic of Dental Medicine, Division of Fixed Prosthodontics-Biomaterials, University of Geneva, Geneva, Switzerland
| | - Susanne S Scherrer
- University Clinic of Dental Medicine, Division of Fixed Prosthodontics-Biomaterials, University of Geneva, Geneva, Switzerland
| | - Jason A Griggs
- Department of Biomedical Materials Science, University of Mississippi Medical Center, MS, USA.
| |
Collapse
|
22
|
Talmazov G, Veilleux N, Abdulmajeed A, Bencharit S. Finite element analysis of a one-piece zirconia implant in anterior single tooth implant applications. PLoS One 2020; 15:e0229360. [PMID: 32092128 PMCID: PMC7039452 DOI: 10.1371/journal.pone.0229360] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2019] [Accepted: 02/04/2020] [Indexed: 11/19/2022] Open
Abstract
This study evaluated the von Mises stress (MPa) and equivalent strain occurring around monolithic yttria-zirconia (Zir) implant using three clinically simulated finite element analysis (FEA) models for a missing maxillary central incisor. Two unidentified patients' cone-beam computed tomography (CBCT) datasets with and without right maxillary central incisor were used to create the FEA models. Three different FEA models were made with bone structures that represent a healed socket (HS), reduced bone width edentulous site (RB), and immediate extraction socket with graft (EG). A one-piece abutment-implant fixture mimicking Straumann Standard Plus tissue level RN 4.1 X 11.8mm, for titanium alloy (Ti) and Zir were modeled. 178 N oblique load and 200 N vertical load were used to simulate occlusal loading. Von Mises stress and equivalent strain values for around each implant model were measured. Within the HS and RB models the labial-cervical region in the cortical bone exhibited highest stress, with Zir having statistically significant lower stress-strain means than Ti in both labial and palatal aspects. For the EG model the labial-cervical area had no statistically significant difference between Ti and Zir; however, Zir performed better than Ti against the graft. FEA models suggest that Ti, a more elastic material than Zir, contributes to the transduction of more overall forces to the socket compared to Zir. Thus, compared to Ti implants, Zir implants may be less prone to peri-implant bone overloading and subsequent bone loss in high stress areas especially in the labial-cervical region of the cortical bone. Zir implants respond to occlusal loading differently than Ti implants. Zir implants may be more favorable in non-grafted edentulous or immediate extraction with grafting.
Collapse
Affiliation(s)
- Georgi Talmazov
- Department of General Practice, School of Dentistry, Virginia Commonwealth University, Richmond, Virginia, United States of America
| | - Nathan Veilleux
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, Virginia, United States of America
| | - Aous Abdulmajeed
- Department of General Practice, School of Dentistry, Virginia Commonwealth University, Richmond, Virginia, United States of America
| | - Sompop Bencharit
- Department of General Practice, School of Dentistry, Virginia Commonwealth University, Richmond, Virginia, United States of America
- Department of Biomedical Engineering, College of Engineering, Virginia Commonwealth University, Richmond, Virginia, United States of America
- Department of Oral & Maxillofacial Surgery, School of Dentistry Commonwealth University, Richmond, Virginia, United States of America
- * E-mail:
| |
Collapse
|
23
|
Clinical performance of zirconia implants: A meta-review. J Prosthet Dent 2019; 123:419-426. [PMID: 31451193 DOI: 10.1016/j.prosdent.2019.05.017] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2019] [Revised: 05/17/2019] [Accepted: 05/17/2019] [Indexed: 12/11/2022]
Abstract
STATEMENT OF PROBLEM The clinical effectiveness of zirconia implants as an alternative to titanium implants is still controversial. PURPOSE The purpose of this analysis was to identify and evaluate systematic reviews reporting on the clinical outcomes of zirconia implants for oral rehabilitation. MATERIAL AND METHODS An electronic search was undertaken on MEDLINE, Embase, and the Cochrane Oral Health Reviews databases up to December 24, 2018, without language restriction. Eligible reviews were screened and assessed. The eligibility criteria were systematic reviews or meta-analyses, implant survival rate, implant success, marginal bone loss, peri-implant soft tissue status, and biologic and functional complications of zirconia implants. Two review authors independently evaluated the quality assessment of the secondary studies by applying the Assessing the Methodological Quality of Systematic Reviews (AMSTAR) tool. RESULTS Nine reviews fulfilled the inclusion criteria and were evaluated. Seven reviews were classified as moderate and 2 as high quality. The overall AMSTAR's quality of these reports was moderate. In the primary studies contained in these reviews, zirconia implant clinical outcomes were found to be similar or inferior to those for titanium implants. The few primary clinical studies contained in these reviews were not homogeneous among each other, presented poor methodology, and only offered promising short-term outcomes due to the lack of long-term follow-ups. CONCLUSIONS Based on this meta-review, in spite of short-term promising results of zirconia implants, evidence with long term is lacking.
Collapse
|
24
|
Siddiqui DA, Sridhar S, Wang F, Jacob JJ, Rodrigues DC. Can Oral Bacteria and Mechanical Fatigue Degrade Zirconia Dental Implants in Vitro? ACS Biomater Sci Eng 2019; 5:2821-2833. [DOI: 10.1021/acsbiomaterials.9b00223] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Danyal A. Siddiqui
- Department of Bioengineering, The University of Texas at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Sathyanarayanan Sridhar
- Department of Bioengineering, The University of Texas at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Frederick Wang
- Department of Bioengineering, The University of Texas at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Joel J. Jacob
- Department of Biological Sciences, The University of Texas at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| | - Danieli C. Rodrigues
- Department of Bioengineering, The University of Texas at Dallas, 800 W. Campbell Road, Richardson, Texas 75080, United States
| |
Collapse
|
25
|
Roehling S, Schlegel KA, Woelfler H, Gahlert M. Zirconia compared to titanium dental implants in preclinical studies—A systematic review and meta‐analysis. Clin Oral Implants Res 2019; 30:365-395. [DOI: 10.1111/clr.13425] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2018] [Revised: 02/27/2019] [Accepted: 03/12/2019] [Indexed: 12/22/2022]
Affiliation(s)
- Stefan Roehling
- Clinic for Oral and Cranio‐Maxillofacial Surgery Hightech Research Center University Hospital Basel University of Basel Basel Switzerland
- Clinic for Oral and Cranio‐Maxillofacial Surgery Kantonsspital Aarau Aarau Switzerland
- Unit for Oral & Maxillofacial Surgery Medical Healthcare Center Lörrach Lörrach Germany
| | - Karl A. Schlegel
- Private Clinic for Oral and Maxillofacial Surgery Prof. Schlegel Munich Germany
- Maxillofacial Surgery Department University Hospital Erlangen University of Erlangen Erlangen Germany
| | | | - Michael Gahlert
- Clinic for Oral and Cranio‐Maxillofacial Surgery Hightech Research Center University Hospital Basel University of Basel Basel Switzerland
- Dental Clinic for Oral Surgery and Implant Dentistry Prof. Gahlert Munich Germany
- Department for Oral Surgery Faculty of Medicine Sigmund Freud University Vienna Vienna Austria
| |
Collapse
|
26
|
Lorenz J, Giulini N, Hölscher W, Schwiertz A, Schwarz F, Sader R. Prospective controlled clinical study investigating long‐term clinical parameters, patient satisfaction, and microbial contamination of zirconia implants. Clin Implant Dent Relat Res 2019; 21:263-271. [DOI: 10.1111/cid.12720] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 01/03/2019] [Accepted: 01/07/2019] [Indexed: 10/27/2022]
Affiliation(s)
- Jonas Lorenz
- Department of Oral, Maxillofacial and Plastic Facial SurgeryJohann‐Wolfgang Goethe University Frankfurt/Main Germany
| | | | | | | | - Frank Schwarz
- Department of Oral Surgery and Implantology, CarolinumJohann Wolfgang Goethe‐University Frankfurt/Main Germany
| | - Robert Sader
- Department of Oral, Maxillofacial and Plastic Facial SurgeryJohann‐Wolfgang Goethe University Frankfurt/Main Germany
| |
Collapse
|
27
|
Translational research on clinically failed zirconia implants. Dent Mater 2018; 35:368-388. [PMID: 30551804 DOI: 10.1016/j.dental.2018.11.033] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Revised: 11/27/2018] [Accepted: 11/28/2018] [Indexed: 12/13/2022]
Abstract
OBJECTIVES To provide fractographic analysis of clinically fractured zirconia implants recovered with their cemented crown. To calculate bending moments, corresponding stress and crack onset location on the implant's fracture surface using a mathematical model integrating spatial coordinates of the crown-implant part and occlusal loading obtained from 2D and 3D images. METHODS 15 fractured zirconia implants parts (11 posterior and 4 anterior) with their all- ceramic crowns still cemented on it were recovered. The implants were first generations from four manufacturers (AXIS Biodental, Z-Systems, Straumann, Swiss Dental Solutions). The time-to-failure varied between 2weeks and 9years. Fractography was performed identifying the failure origin and characteristic surface crack features. From 2D and 3D digital images of the crown-implant part, spatial coordinates anchoring the crown's occlusal contacts with the implant's central axis and reference plane were integrated in a mathematical model spreadsheet. Loads of 500 N in total were selectively distributed over identified occlusal contacts from wear patterns. The resultant bending and torsion moments, corresponding shear, tensile, maximum principal stress and von Mises stress were calculated. The fracture crack onset location on the implant's fracture surface was given by an angular position with respect to an occlusal reference and compared with the location of the fracture origin identified from fractographic analysis. RESULTS Implants fractured from the periphery of the smaller inner diameter between two threads at the bone-entrance level except for one implant which failed half-way within the bone. The porous coating (AXIS Biodental) and the large grit alumina sandblasting (Z-System) created surface defects directly related to the fracture origin. The model spreadsheet showed how occlusal loading with respect to the implant's central axis affects bending moments and crack onset. Dominant loads distributed on contacts with important wear pattern provided a calculated crack onset location in good agreement with the fractographic findings of the fracture origin. SIGNIFICANCE Recovered broken zirconia implant parts with their restorative crowns can provide not only information regarding the failure origin using fractography but also knowledge regarding occlusal crown loading with respect to the implant's axis. The mathematical model was helpful in showing how occlusal loading affects the location of the fracture initiation site on clinical zirconia implant fracture cases.
Collapse
|
28
|
Steiger-Ronay V, Krcmaric Z, Schmidlin PR, Sahrmann P, Wiedemeier DB, Benic GI. Assessment of peri-implant defects at titanium and zirconium dioxide implants by means of periapical radiographs and cone beam computed tomography: An in-vitro examination. Clin Oral Implants Res 2018; 29:1195-1201. [PMID: 30387207 DOI: 10.1111/clr.13383] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Revised: 10/25/2018] [Accepted: 10/28/2018] [Indexed: 11/29/2022]
Abstract
OBJECTIVE To test the accuracy of measurement of interproximal peri-implant bone defects at titanium (Ti) and zirconium dioxide (ZrO2 ) implants by digital periapical radiography (PR) and cone beam computed tomography (CBCT). MATERIAL AND METHODS A total of 18 models, each containing one Ti and one ZrO2 implant, were cast in dental stone. Six models each were allocated to following defect groups: A-no peri-implant defect, B-1 mm width defect, C-1.5 mm width defect. The defect width was measured with a digital sliding caliper. Subsequently, the models were scanned by means of PR and CBCT. Three examiners assessed the defect width on PR and CBCT. Wilcoxon signed-rank test and Wilcoxon rank sum test were applied to detect differences between imaging techniques and implant types. RESULTS For PR, the deviation of the defect width measurement (mm) for groups A, B, and C amounted to 0.01 ± 0.03, -0.02 ± 0.06, and -0.00 ± 0.04 at Ti and 0.05 ± 0.02, 0.01 ± 0.03, and 0.09 ± 0.03 at ZrO2 implants. The corresponding values (mm) for CBCT reached 0.10 ± 0.11, 0.26 ± 0.05, and 0.24 ± 0.08 at Ti and 1.07 ± 0.06, 0.64 ± 0.37, and 0.54 ± 0.17 at ZrO2 implants. Except for Ti with defect A, measurements in PR were significantly more accurate in comparison to CBCT (p ≤ 0.05). Both methods generally yielded more accurate measurements for Ti than for ZrO2 . CONCLUSIONS The assessment of interproximal peri-implant defect width at Ti and ZrO2 implants was more accurate in PR in comparison to CBCT. Measurements in CBCT always led to an overestimation of the defect width, reaching clinical relevance for ZrO2 implants.
Collapse
Affiliation(s)
- Valerie Steiger-Ronay
- Clinic of Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | | | - Patrick R Schmidlin
- Clinic of Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Philipp Sahrmann
- Clinic of Preventive Dentistry, Periodontology and Cariology, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Daniel B Wiedemeier
- Statistical Services, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - Goran I Benic
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| |
Collapse
|
29
|
Roehling S, Schlegel KA, Woelfler H, Gahlert M. Performance and outcome of zirconia dental implants in clinical studies: A meta‐analysis. Clin Oral Implants Res 2018; 29 Suppl 16:135-153. [DOI: 10.1111/clr.13352] [Citation(s) in RCA: 55] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Revised: 02/28/2018] [Accepted: 07/04/2018] [Indexed: 12/14/2022]
Affiliation(s)
- Stefan Roehling
- Clinic for Oral and Cranio‐Maxillofacial SurgeryHightech Research CenterUniversity Hospital BaselUniversity of Basel Basel Switzerland
- Clinic for Oral and Cranio‐Maxillofacial SurgeryKantonsspital Aarau Aarau Switzerland
- Unit for Oral & Maxillofacial SurgeryMedical Healthcare Center Lörrach Lörrach Germany
| | - Karl A. Schlegel
- Private Clinic for Oral and Maxillofacial Surgery Prof. Schlegel Munich Germany
- Maxillofacial Surgery DepartmentUniversity Hospital ErlangenUniversity of Erlangen Erlangen Germany
| | | | - Michael Gahlert
- Clinic for Oral and Cranio‐Maxillofacial SurgeryHightech Research CenterUniversity Hospital BaselUniversity of Basel Basel Switzerland
- Private Dental Clinic PD Dr. Gahlert Munich Germany
| |
Collapse
|
30
|
Gui J, Huang C, Yuan J, Huang Q, Long F, Ma A, Pan J. Handy cloud point extraction coupled with inductively coupled plasma mass spectrometry for analysis of trace zirconium in complex biological samples. Microchem J 2018. [DOI: 10.1016/j.microc.2018.01.013] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
31
|
Bosshardt DD, Chappuis V, Buser D. Osseointegration of titanium, titanium alloy and zirconia dental implants: current knowledge and open questions. Periodontol 2000 2018; 73:22-40. [PMID: 28000277 DOI: 10.1111/prd.12179] [Citation(s) in RCA: 294] [Impact Index Per Article: 42.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Bone healing around dental implants follows the pattern and sequence of intramembraneous osteogenesis with formation of woven bone first of all followed later by formation of parallel-fibered and lamellar bone. Bone apposition onto the implant surface starts earlier in trabecular bone than in compact bone. While the first new bone may be found on the implant surface around 1 week after installation, bone remodeling starts at between 6 and 12 weeks and continues throughout life. Bone remodeling also involves the bone-implant interface, thus transiently exposing portions of the implant surface. Surface modifications creating micro-rough implant surfaces accelerate the osseointegration process of titanium implants, as demonstrated in numerous animal experiments. Sandblasting followed by acid-etching may currently be regarded as the gold standard technique to create micro-rough surfaces. Chemical surface modifications, resulting in higher hydrophilicity, further increase the speed of osseointegration of titanium and titanium-zirconium implants in both animals and humans. Surface modifications of zirconia and alumina-toughened zirconia implants also have an influence on the speed of osseointegration, and some implant types reach high bone-to-implant contact values in animals. Although often discussed independently of each other, surface characteristics, such as topography and chemistry, are virtually inseparable. Contemporary, well-documented implant systems with micro-rough implant surfaces, placed by properly trained and experienced clinicians, demonstrate high long-term survival rates. Nevertheless, implant failures do occur. A low percentage of implants are diagnosed with peri-implantitis after 10 years in function. In addition, a low number of implants seem to be lost for primarily reasons other than biofilm-induced infection. Patient factors, such as medications interfering with the immune system and bone cells, may be an element contributing to continuous bone loss and should therefore be monitored and studied in greater detail.
Collapse
|
32
|
Ultimate force and stiffness of 2-piece zirconium dioxide implants with screw-retained monolithic lithium-disilicate reconstructions. J Prosthodont Res 2018; 62:258-263. [DOI: 10.1016/j.jpor.2017.11.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Revised: 09/01/2017] [Accepted: 11/13/2017] [Indexed: 11/21/2022]
|
33
|
Mussano F, Genova T, Serra FG, Carossa M, Munaron L, Carossa S. Nano-Pore Size of Alumina Affects Osteoblastic Response. Int J Mol Sci 2018; 19:E528. [PMID: 29425177 PMCID: PMC5855750 DOI: 10.3390/ijms19020528] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Revised: 02/04/2018] [Accepted: 02/06/2018] [Indexed: 01/31/2023] Open
Abstract
The rapid development and application of nanotechnology to biological interfaces has impacted the bone implant field, allowing researchers to finely modulate the interface between biomaterials and recipient tissues. In the present study, oxidative anodization was exploited to generate two alumina surfaces with different pore diameters. The former displayed surface pores in the mean range of 16-30 nm, while in the latter pores varied from to 65 to 89 nm. The samples were characterized by Field Emission Scanning Electron Microscopy (FESEM) and Energy Dispersive X-ray spectroscopy (EDX) analysis prior to being tested with pre-osteoblastic MC3T3-E1 cells. In vitro cell response was studied in terms of early cell adhesion, viability, and morphology, including focal adhesion quantification. Both the alumina samples promoted higher cell adhesion and viability than the control condition represented by the standard culture dish plastic. Osteogenic differentiation was assessed through alkaline phosphatase activity and extracellular calcium deposition, and it was found that of the two nano-surfaces, one was more efficient than the other. By comparing for the first time two nano-porous alumina surfaces with different pore diameters, our data supported the role of nano-topography in inducing cell response. Modulating a simple aspect of surface texture may become an attractive route for guiding bone healing and regeneration around implantable metals.
Collapse
Affiliation(s)
- Federico Mussano
- CIR Dental School, Department of Surgical Sciences, University of Turin, via Nizza 230, 10126 Turin, Italy.
| | - Tullio Genova
- CIR Dental School, Department of Surgical Sciences, University of Turin, via Nizza 230, 10126 Turin, Italy.
- Department of Life Sciences and Systems Biology, UNITO, via Accademia Albertina 13, 10123 Turin, Italy.
| | - Francesca Giulia Serra
- Department of Mechanical and Aerospatial Engineering (DIMEAS), Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129 Turin, Italy.
| | - Massimo Carossa
- CIR Dental School, Department of Surgical Sciences, University of Turin, via Nizza 230, 10126 Turin, Italy.
| | - Luca Munaron
- Department of Life Sciences and Systems Biology, UNITO, via Accademia Albertina 13, 10123 Turin, Italy.
- Centre for Nanostructured Interfaces and Surfaces (NIS), via Quarello 11/A, 10135 Turin, Italy.
| | - Stefano Carossa
- CIR Dental School, Department of Surgical Sciences, University of Turin, via Nizza 230, 10126 Turin, Italy.
| |
Collapse
|
34
|
Zaugg LK, Zehnder I, Rohr N, Fischer J, Zitzmann NU. The effects of crown venting or pre-cementing of CAD/CAM-constructed all-ceramic crowns luted on YTZ implants on marginal cement excess. Clin Oral Implants Res 2017; 29:82-90. [DOI: 10.1111/clr.13071] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/09/2017] [Indexed: 11/29/2022]
Affiliation(s)
- Lucia K. Zaugg
- Department of Periodontology, Endodontology and Cariology; University Center for Dental Medicine Basel, University of Basel; Basel Switzerland
- Centre for Craniofacial and Regenerative Biology, Dental Institute; King's College London; London UK
| | - Isabella Zehnder
- Department of Periodontology, Endodontology and Cariology; University Center for Dental Medicine Basel, University of Basel; Basel Switzerland
| | - Nadja Rohr
- Department of Reconstructive Dentistry and Temporomandibular Disorders; University Center for Dental Medicine Basel, University of Basel; Basel Switzerland
| | - Jens Fischer
- Department of Reconstructive Dentistry and Temporomandibular Disorders; University Center for Dental Medicine Basel, University of Basel; Basel Switzerland
| | - Nicola U. Zitzmann
- Department of Periodontology, Endodontology and Cariology; University Center for Dental Medicine Basel, University of Basel; Basel Switzerland
- Department of Reconstructive Dentistry and Temporomandibular Disorders; University Center for Dental Medicine Basel, University of Basel; Basel Switzerland
| |
Collapse
|
35
|
Abdallah MN, Badran Z, Ciobanu O, Hamdan N, Tamimi F. Strategies for Optimizing the Soft Tissue Seal around Osseointegrated Implants. Adv Healthc Mater 2017; 6. [PMID: 28960892 DOI: 10.1002/adhm.201700549] [Citation(s) in RCA: 54] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 07/12/2017] [Indexed: 12/20/2022]
Abstract
Percutaneous and permucosal devices such as catheters, infusion pumps, orthopedic, and dental implants are commonly used in medical treatments. However, these useful devices breach the soft tissue barrier that protects the body from the outer environment, and thus increase bacterial infections resulting in morbidity and mortality. Such associated infections can be prevented if these devices are effectively integrated with the surrounding soft tissue, and thus creating a strong seal from the surrounding environment. However, so far, there are no percutaneous/permucosal medical devices able to prevent infection by achieving strong integration at the soft tissue-device interface. This review gives an insight into the current status of research into soft tissue-implant interface and the challenges associated with these interfaces. Biological soft/hard tissue interfaces may provide insights toward engineering better soft tissue interfaces around percutaneous devices. In this review, focus is put on the history and current findings as well as recent progress of the strategies aiming to develop a strong soft tissue seal around osseointegrated implants, such as orthopedic and dental implants.
Collapse
Affiliation(s)
- Mohamed-Nur Abdallah
- Division of Biomedical Sciences; Faculty of Dentistry; McGill University; Montreal H3A 1G1 QC Canada
- Division of Orthodontics; Faculty of Dentistry; Toronto University; Toronto M5G 1G6 ON Canada
| | - Zahi Badran
- Division of Biomedical Sciences; Faculty of Dentistry; McGill University; Montreal H3A 1G1 QC Canada
- Department of Periodontology (CHU/Rmes Inserm U1229/UIC11); Faculty of Dental Surgery; University of Nantes; Nantes 44042 France
| | - Ovidiu Ciobanu
- Division of Biomedical Sciences; Faculty of Dentistry; McGill University; Montreal H3A 1G1 QC Canada
| | - Nader Hamdan
- Department of Dental Clinical Sciences; Faculty of Dentistry; Dalhousie University; Halifax B3H 4R2 NS Canada
| | - Faleh Tamimi
- Division of Biomedical Sciences; Faculty of Dentistry; McGill University; Montreal H3A 1G1 QC Canada
| |
Collapse
|
36
|
Ahmed NA, Jacob CA, Nittla PP. Immediate Placement of Zirconia Implants in Teeth with Periapical Lesions: A Case Report. J Clin Diagn Res 2017; 11:ZD26-ZD28. [PMID: 28511528 DOI: 10.7860/jcdr/2017/23552.9628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2016] [Accepted: 12/23/2016] [Indexed: 11/24/2022]
Abstract
This case report records the replacement of two failed endodontically treated mandibular molars with one piece zirconia implants in a patient with metal hypersensitivity. The two molars were atraumatically extracted and curetted to remove any remnants of a periapical granuloma. Immediate implant placement with primary stability was achieved using one piece WhiteSky® Bredent zirconia implants which were restored after four months with a zirconia crown. One year follow up revealed successful osseointegration with optimal form and function.
Collapse
Affiliation(s)
- Nizar A Ahmed
- Senior Lecturer, Department of Periodontics, Thai Moogambigai Dental College, Chennai, Tamil Nadu, India
| | - Caroline Annette Jacob
- Senior Lecturer, Department of Periodontics, Saveetha Dental College, Chennai, Tamil Nadu, India
| | - Preetham Prasad Nittla
- Senior Lecturer, Department of Prosthodontics, Saveetha Dental College, Chennai, Tamil Nadu, India
| |
Collapse
|
37
|
Abstract
PURPOSE About 10 years ago, one-piece zirconia implants were introduced to dentistry. The aim of the study was to evaluate the clinical success of two-piece zirconia implants regarding osseointegration using the manufacturers' warranty data. MATERIALS AND METHODS Over a period of 4 years (2010-2014), the data of warranty replacements of 15,255 sold Zeramex implants were evaluated retrospectively and blinded. RESULTS Three hundred forty-seven (2.2%) nonosseointegrated implants were sent back. Zeramex T showed an average success rate of 96.7%, whereas Zeralock implants exhibited an average success rate of 98.5%. Furthermore, Zeramex Plus implants exhibit an average success rate of 99.4% within the investigated period. Assuming, that 2% of the failed implants were unreturned, the above-mentioned values show no changes. Assuming 5% (10%) of unreturned nonosseointegrated implants, the average success rate of Zeramex T decreases from 96.7% to 96.6% (96.4%) and of Zeralock from 98.5% to 98.4% (98.4%), respectively. The success rate of Zeramex Plus implants remains unchanged at 99.4%. CONCLUSION The results of this study imply that two-piece zirconia implants show competitive success rates, improved from >96.7% to >98.5% over three product generations.
Collapse
|
38
|
One-Piece Zirconia Ceramic versus Titanium Implants in the Jaw and Femur of a Sheep Model: A Pilot Study. BIOMED RESEARCH INTERNATIONAL 2016; 2016:6792972. [PMID: 28058261 PMCID: PMC5183747 DOI: 10.1155/2016/6792972] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2016] [Revised: 10/17/2016] [Accepted: 11/08/2016] [Indexed: 11/17/2022]
Abstract
Reports have documented titanium (Ti) hypersensitivity after dental implant treatment. Alternative materials have been suggested including zirconia (Zr) ceramics, which have shown predictable osseointegration in animal studies and appear free of immune responses. The aim of the research was to investigate the bone-to-implant contact (BIC) of one-piece Zr, compared with one-piece Ti implants, placed in the jaws and femurs of domestic sheep. Ten New Zealand mixed breed sheep were used. A One-piece prototype Ti (control) and one Zr (test) implant were placed in the mandible, and one of each implant (Ti and Zr) was placed into the femoral epicondyle of each animal. The femur implants were submerged and unloaded; the mandibular implants were placed using a one-stage transgingival protocol and were nonsubmerged. After a healing period of 12 weeks, %BIC was measured. The overall survival rate for mandibular and femur implants combined was 87.5%. %BIC was higher for Zr implants versus Ti implants in the femur (85.5%, versus 78.9%) (p = 0.002). Zirconia implants in the mandible showed comparable %BIC to titanium implants (72.2%, versus 60.3%) (p = 0.087). High failure rate of both Zr and Ti one-piece implants in the jaw could be attributed to the one-piece design and surface characteristics of the implant that could have influenced osseointegration. Further clinical trials are recommended to evaluate the performance of zirconia implants under loading conditions.
Collapse
|
39
|
Cionca N, Hashim D, Cancela J, Giannopoulou C, Mombelli A. Pro-inflammatory cytokines at zirconia implants and teeth. A cross-sectional assessment. Clin Oral Investig 2016; 20:2285-2291. [PMID: 26832782 PMCID: PMC5069320 DOI: 10.1007/s00784-016-1729-z] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2015] [Accepted: 01/18/2016] [Indexed: 10/27/2022]
Abstract
OBJECTIVES The aim of this study was to compare the expression of host-derived markers in peri-implant/gingival crevicular fluid (PCF/GCF) and clinical conditions at ceramic implants and contralateral natural teeth. As a secondary objective, we compared zirconia implants with titanium implants. METHODS One zirconia implant (ZERAMEX® Implant System) and one contralateral natural tooth were examined in 36 systemically healthy subjects (21 males, 15 females, mean age 58). The levels of Il-1β, Il-1RA, Il-6, Il-8, Il-17, b-FGF, G-CSF, GM-CSF, IFNɣ, MIP-1β, TNF-α, and VEGF were assessed in PCF/GCF using the Bio-Plex 200 Suspension Array System. The plaque index (PI), gingival index (GI), probing depth (PD), and bleeding on probing (BOP) were assessed at six sites around each implant or tooth. Titanium implants were also assessed when present (n = 9). RESULTS The zirconia implants were examined after a loading period of at least 1.2 years (average 2.2 years). The mean PI was significantly lower at zirconia implants compared to teeth (p = 0.003), while the mean GI, PD, and BOP were significantly higher (p < 0.001). A correlation was found in the expression of Il-1RA, Il-8, G-CSF, MIP-1β, and TNF-α at zirconia implants and teeth. The levels of IL-1β and TNF-α were significantly higher at zirconia implants than at teeth. No significant differences were found between zirconia and titanium implants. A correlation was found between the levels of IL-1RA, IL-8, GM-CSF, and MIP-1β at zirconia and titanium implants. CONCLUSIONS The correlation in the expression of five biomarkers at zirconia implants and teeth, and of four biomarkers at zirconia and titanium implants, is compatible with the existence of a patient-specific inflammatory response pattern. Higher mean GI, PD, and BOP around implants suggests that the peri-implant mucosa may be mechanically more fragile than the gingiva. CLINICAL RELEVANCE Similar expression of selected biomarkers at zirconia implants and teeth and at zirconia and titanium implants reflects existence of patient-specific inflammatory response patterns.
Collapse
Affiliation(s)
- Norbert Cionca
- School of Dental Medicine, Division of Periodontology, University of Geneva, Rue Barthélemy-Menn 19, CH-1205, Geneva, Switzerland.
| | - Dena Hashim
- School of Dental Medicine, Division of Periodontology, University of Geneva, Rue Barthélemy-Menn 19, CH-1205, Geneva, Switzerland
| | - Jose Cancela
- School of Dental Medicine, Division of Periodontology, University of Geneva, Rue Barthélemy-Menn 19, CH-1205, Geneva, Switzerland
| | - Catherine Giannopoulou
- School of Dental Medicine, Division of Periodontology, University of Geneva, Rue Barthélemy-Menn 19, CH-1205, Geneva, Switzerland
| | - Andrea Mombelli
- School of Dental Medicine, Division of Periodontology, University of Geneva, Rue Barthélemy-Menn 19, CH-1205, Geneva, Switzerland
| |
Collapse
|
40
|
Abstract
INTRODUCTION The use of zirconia in medicine and dentistry has rapidly expanded over the past decade, driven by its advantageous physical, biological, esthetic, and corrosion properties. Zirconia orthopedic hip replacements have shown superior wear-resistance over other systems; however, risk of catastrophic fracture remains a concern. In dentistry, zirconia has been widely adopted for endosseous implants, implant abutments, and all-ceramic crowns. Because of an increasing demand for esthetically pleasing dental restorations, zirconia-based ceramic restorations have become one of the dominant restorative choices. Areas covered: This review provides an updated overview of the applications of zirconia in medicine and dentistry with a focus on dental applications. The MEDLINE electronic database (via PubMed) was searched, and relevant original and review articles from 2010 to 2016 were included. Expert commentary: Recent data suggest that zirconia performs favorably in both orthopedic and dental applications, but quality long-term clinical data remain scarce. Concerns about the effects of wear, crystalline degradation, crack propagation, and catastrophic fracture are still debated. The future of zirconia in biomedical applications will depend on the generation of these data to resolve concerns.
Collapse
Affiliation(s)
- Yen-Wei Chen
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| | - Joelle Moussi
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| | - Jeanie L Drury
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| | - John C Wataha
- a Department of Restorative Dentistry , University of Washington School of Dentistry , Seattle , WA , USA
| |
Collapse
|
41
|
Mihatovic I, Golubovic V, Becker J, Schwarz F. Bone tissue response to experimental zirconia implants. Clin Oral Investig 2016; 21:523-532. [PMID: 27501958 DOI: 10.1007/s00784-016-1904-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2014] [Accepted: 07/06/2016] [Indexed: 11/25/2022]
Abstract
OBJECTIVES This study seeks to assess the bone tissue response at experimental zirconia implants in comparison with titanium implants by means of descriptive histology and histomorphometry in a dog model. MATERIALS AND METHODS Experimental zirconia implants with three different surface roughnesses (Z1 < Z2 < Z3) and conventional sandblasted large grit and acid-etched titanium implants were inserted bilaterally in the lower jaws of nine beagle dogs. Tissue biopsies were obtained after 3 and 14 days and 10 weeks of transmucosal healing. The tissue response was investigated by assessing new, old, and total bone-to-implant contact (nBIC, oBIC, and tBIC). RESULTS After 3 days, histological specimens of all groups showed an intimate contact between the implant threads and pristine bone (tBIC: Ti 42.3 % > Z2 30.1 % > Z3 28.9 % > Z1 25.1 %, p > 0.05, unpaired t test, respectively). A provisional matrix was evident at all implant surfaces. At 14 days, percentages of BIC increased in all groups (tBIC: Ti 62.1 % > Z3 69.2 % < Z2 44.4 % > Z1 42.3 %; nBIC: Z3 58.9 % > Ti 52.2 % > Z2 35.1 % > Z1 32.5 %). Two implants, one of group Z1 and one of group Z2, were lost. At 10 weeks, 13 of 18 zirconia implants were lost, equally distributed between all three surface modifications. The remaining implants revealed increased BIC values (tBIC: Z3 69.5 % > Ti 58.5 % > Z1 49.7 % > Z2 37.1 %; nBIC: Z3 57.2 % > Ti 46.5 % > Z1 32.3 % > Z2 29.3 %). Histomorphometrical analysis showed comparable mean BIC values in all groups at all healing periods without showing statistical differences (p > 0.05, unpaired t test, respectively). CONCLUSION The bone tissue response throughout the healing periods was characterized by a constant bone remodeling accompanied by resorption of old bone in favor of new bone formation at both titanium and zirconia implants. Surface roughness had a positive effect on BIC, although not showing statistical significance. Due to the poor survival rate, the experimental zirconia implants investigated may not be suitable for clinical use. CLINICAL RELEVANCE Zirconia has been introduced as an alternative biomaterial for dental implants. A profound knowledge about the bone tissue response at zirconia implant surfaces is necessary as it plays an important role for proper osseointegration and long-term stability.
Collapse
Affiliation(s)
- Ilja Mihatovic
- Department of Oral Surgery, Heinrich Heine University, Düsseldorf, Germany.
- Department of Oral Surgery, Westdeutsche Kieferklinik, Heinrich Heine University, 40225, Düsseldorf, Germany.
| | - Vladimir Golubovic
- Department of Oral Surgery, Heinrich Heine University, Düsseldorf, Germany
| | - Jürgen Becker
- Department of Oral Surgery, Heinrich Heine University, Düsseldorf, Germany
| | - Frank Schwarz
- Department of Oral Surgery, Heinrich Heine University, Düsseldorf, Germany
| |
Collapse
|
42
|
Al-Ahmad A, Karygianni L, Schulze Wartenhorst M, Bächle M, Hellwig E, Follo M, Vach K, Han JS. Bacterial adhesion and biofilm formation on yttria-stabilized, tetragonal zirconia and titanium oral implant materials with low surface roughness - an in situ study. J Med Microbiol 2016; 65:596-604. [DOI: 10.1099/jmm.0.000267] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023] Open
Affiliation(s)
- Ali Al-Ahmad
- Department of Operative Dentistry and Periodontology, University Hospital Freiburg, School of Dentistry, Freiburg, Germany
| | - Lamprini Karygianni
- Department of Operative Dentistry and Periodontology, University Hospital Freiburg, School of Dentistry, Freiburg, Germany
| | - Max Schulze Wartenhorst
- Department of Operative Dentistry and Periodontology, University Hospital Freiburg, School of Dentistry, Freiburg, Germany
| | - Maria Bächle
- Department of Prosthodontics, University Hospital Freiburg, School of Dentistry, Freiburg, Germany
| | - Elmar Hellwig
- Department of Operative Dentistry and Periodontology, University Hospital Freiburg, School of Dentistry, Freiburg, Germany
| | - Marie Follo
- Department of Hematology and Oncology, Core Facility, Albert Ludwigs University, Freiburg, Germany
| | - Kirstin Vach
- Center for Medical Biometry and Medical Informatics, Institute for Medical Biometry and Statistics, Medical Center, University of Freiburg, Freiburg, Germany
| | - Jung-Suk Han
- Department of Prosthodontics, School of Dentistry, Seoul National University, Seoul, South Korea
| |
Collapse
|
43
|
Hashim D, Cionca N, Courvoisier DS, Mombelli A. A systematic review of the clinical survival of zirconia implants. Clin Oral Investig 2016; 20:1403-17. [PMID: 27217032 PMCID: PMC4992030 DOI: 10.1007/s00784-016-1853-9] [Citation(s) in RCA: 95] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2016] [Accepted: 05/06/2016] [Indexed: 12/29/2022]
Abstract
OBJECTIVES The aim of this review was to evaluate the clinical success and survival rates of zirconia ceramic implants after at least 1 year of function and to assess if there is sufficient evidence to justify using them as alternatives to titanium implants. MATERIALS AND METHODS An electronic search in MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Clinical Trials (CENTRAL) databases was performed in April 2015 by two independent examiners to retrieve clinical studies focusing on the survival rate of zirconia implants after at least 1 year of function. Implant survival was estimated using the overall proportion reported in the studies with a Clopper-Pearson 95 % confidence interval (random effect model with a Der-Simonian Laird estimate). RESULTS Fourteen articles were selected out of the 1519 titles initially screened. The overall survival rate of zirconia one- and two-piece implants was calculated at 92 % (95 % CI 87-95) after 1 year of function. The survival of implants at 1 year for the selected studies revealed considerable heterogeneity. CONCLUSIONS In spite of the unavailability of sufficient long-term evidence to justify using zirconia oral implants, zirconia ceramics could potentially be the alternative to titanium for a non-metallic implant solution. However, further clinical studies are required to establish long-term results, and to determine the risk of technical and biological complications. Additional randomized controlled clinical trials examining two-piece zirconia implant systems are also required to assess their survival and success rates in comparison with titanium as well as one-piece zirconia implants. CLINICAL RELEVANCE Zirconia implants provide a potential alternative to titanium ones. However, clinicians must be aware of the lack of knowledge regarding long-term outcomes and specific reasons for failure.
Collapse
Affiliation(s)
- Dena Hashim
- School of Dental Medicine, Division of Periodontology, University of Geneva, Rue Barthelemy-Menn 19, CH-1205, Geneva, Switzerland.
| | - Norbert Cionca
- School of Dental Medicine, Division of Periodontology, University of Geneva, Rue Barthelemy-Menn 19, CH-1205, Geneva, Switzerland
| | - Delphine S Courvoisier
- University Hospitals of Geneva, Rue Gabrielle-Perret-Gentil 4, CH-1205, Genève, Switzerland
| | - Andrea Mombelli
- School of Dental Medicine, Division of Periodontology, University of Geneva, Rue Barthelemy-Menn 19, CH-1205, Geneva, Switzerland
| |
Collapse
|
44
|
Preis V, Kammermeier A, Handel G, Rosentritt M. In vitro performance of two-piece zirconia implant systems for anterior application. Dent Mater 2016; 32:765-74. [PMID: 27068740 DOI: 10.1016/j.dental.2016.03.028] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2015] [Revised: 02/03/2016] [Accepted: 03/22/2016] [Indexed: 11/30/2022]
Abstract
OBJECTIVES To investigate the influence of the implant-abutment connection on the long-term in vitro performance and fracture resistance of two-piece zirconia implant systems for anterior application. METHODS Six groups of two-piece zirconia implant systems (n=10/group) with screw-retained (5×) or bonded (1×) connections were restored with full-contour zirconia crowns. A two-piece screw-retained titanium system served as reference. For simulating anterior loading the specimens (n=8/group) were mounted at an angle of 135° in the chewing simulator, and subjected to thermal cycling (TC: 2×9000×5°/55°C) and mechanical loading (ML: 3.6×10(6)×100N). Failed restorations were examined (scanning electron microscopy). Fracture resistance and maximum bending stress of surviving restorations were determined. 2 specimens per group were loaded to fracture after 24h water storage without TCML. Data were statistically analyzed (ANOVA; Bonferroni; Kaplan-Meier-Log-Rank; α=0.05). RESULTS The bonded zirconia system and the titanium reference survived TCML without any failures. Screw-retained zirconia systems showed fractures of abutments and/or implants, partly combined with screw fracture/loosening. Failure frequency (F) varied between the groups (F=8×: 3 groups, F=3×: 1 group, F=1×: 1 group). The Log-Rank-test showed significant (p=0.000) differences. Fracture forces and maximum bending stresses (mean±standard deviation) differed significantly ( ANOVA p=0.000) between 233.4±31.4N/317.1±42.6N/mm(2) and 404.3±15.1N/549.2±20.5N/mm(2). Fracture forces after TCML were similar to 24h fracture forces. SIGNIFICANCE Screw-retained two-piece zirconia implant systems showed higher failure rates and lower fracture resistance than a screw-retained titanium system, and may be appropriate for clinical anterior requirements with limitations. Failures involved the abutment/implant region around the screw, indicating that the connecting design is crucial for clinical success.
Collapse
Affiliation(s)
- Verena Preis
- Department of Prosthetic Dentistry, Regensburg University Medical Center, 93042 Regensburg, Germany.
| | - Armin Kammermeier
- Department of Prosthetic Dentistry, Regensburg University Medical Center, 93042 Regensburg, Germany
| | - Gerhard Handel
- Department of Prosthetic Dentistry, Regensburg University Medical Center, 93042 Regensburg, Germany
| | - Martin Rosentritt
- Department of Prosthetic Dentistry, Regensburg University Medical Center, 93042 Regensburg, Germany
| |
Collapse
|
45
|
Spies BC, Witkowski S, Butz F, Vach K, Kohal RJ. Bi-layered zirconia/fluor-apatite bridges supported by ceramic dental implants: a prospective case series after thirty months of observation. Clin Oral Implants Res 2015; 27:1265-1273. [DOI: 10.1111/clr.12731] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/17/2015] [Indexed: 11/28/2022]
Affiliation(s)
- Benedikt Christopher Spies
- Medical Center - University of Freiburg; Center for Dental Medicine; Department of Prosthetic Dentistry; Freiburg Germany
| | - Siegbert Witkowski
- Medical Center - University of Freiburg; Center for Dental Medicine; Department of Prosthetic Dentistry; Freiburg Germany
| | - Frank Butz
- Medical Center - University of Freiburg; Center for Dental Medicine; Department of Prosthetic Dentistry; Freiburg Germany
| | - Kirstin Vach
- Medical Center - University of Freiburg; Center for Medical Biometry and Medical Informatics; Institute for Medical Biometry and Statistics; Freiburg Germany
| | - Ralf-Joachim Kohal
- Medical Center - University of Freiburg; Center for Dental Medicine; Department of Prosthetic Dentistry; Freiburg Germany
| |
Collapse
|
46
|
Pozhitkov AE, Daubert D, Brochwicz Donimirski A, Goodgion D, Vagin MY, Leroux BG, Hunter CM, Flemmig TF, Noble PA, Bryers JD. Interruption of Electrical Conductivity of Titanium Dental Implants Suggests a Path Towards Elimination Of Corrosion. PLoS One 2015; 10:e0140393. [PMID: 26461491 PMCID: PMC4604158 DOI: 10.1371/journal.pone.0140393] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2015] [Accepted: 09/24/2015] [Indexed: 01/30/2023] Open
Abstract
Peri-implantitis is an inflammatory disease that results in the destruction of soft tissue and bone around the implant. Titanium implant corrosion has been attributed to the implant failure and cytotoxic effects to the alveolar bone. We have documented the extent of titanium release into surrounding plaque in patients with and without peri-implantitis. An in vitro model was designed to represent the actual environment of an implant in a patient’s mouth. The model uses actual oral microbiota from a volunteer, allows monitoring electrochemical processes generated by biofilms growing on implants and permits control of biocorrosion electrical current. As determined by next generation DNA sequencing, microbial compositions in experiments with the in vitro model were comparable with the compositions found in patients with implants. It was determined that the electrical conductivity of titanium implants was the key factor responsible for the biocorrosion process. The interruption of the biocorrosion current resulted in a 4–5 fold reduction of corrosion. We propose a new design of dental implant that combines titanium in zero oxidation state for osseointegration and strength, interlaid with a nonconductive ceramic. In addition, we propose electrotherapy for manipulation of microbial biofilms and to induce bone healing in peri-implantitis patients.
Collapse
Affiliation(s)
- Alex E. Pozhitkov
- Department of Oral Health Sciences, University of Washington, Box 357444, Seattle, Washington, United States of America
- * E-mail:
| | - Diane Daubert
- Department of Periodontics, University of Washington, Box 357444, Seattle, Washington, United States of America
| | - Ashley Brochwicz Donimirski
- Department of Oral Health Sciences, University of Washington, Box 357444, Seattle, Washington, United States of America
| | - Douglas Goodgion
- Department of Oral Health Sciences, University of Washington, Box 357444, Seattle, Washington, United States of America
| | - Mikhail Y. Vagin
- Department of Physics, Chemistry and Biology (IFM) Linköping University, SE-581 83, LINKÖPING, Sweden
| | - Brian G. Leroux
- Department of Oral Health Sciences, University of Washington, Box 357444, Seattle, Washington, United States of America
| | - Colby M. Hunter
- PhD Program in Microbiology, Alabama State University, Montgomery, Alabama, United States of America
| | - Thomas F. Flemmig
- Faculty of Dentistry, The University of Hong Kong, Prince Philip Dental Hospital, 34 Hospital Road, Sai Ying Pun, Hong Kong SAR, Peoples’ Republic of China
| | - Peter A. Noble
- PhD Program in Microbiology, Alabama State University, Montgomery, Alabama, United States of America
| | - James D. Bryers
- Department of Bioengineering, University of Washington, 3720 15th Avenue NE, Seattle, Washington, United States of America
| |
Collapse
|
47
|
Implant Supported Fixed Dental Prostheses Using a New Monotype Zirconia Implant-A Case Report. Dent J (Basel) 2015; 3:79-92. [PMID: 29567928 PMCID: PMC5851168 DOI: 10.3390/dj3030079] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2015] [Revised: 09/04/2015] [Accepted: 09/10/2015] [Indexed: 11/24/2022] Open
Abstract
Currently, titanium or specific titanium alloys are the most often used materials for the fabrication of dental implants. Many studies have confirmed the osseointegrative capacity and clinical long-term performance of moderately rough titanium implants. However, disadvantages have also been reported with regard to peri-implant infections and the titanium metal properties. Tooth colored ceramic implants have attracted the interest of clinicians since the end of the 1960s. Initially, alumina was used for the fabrication of ceramic implants; however, due to the poor biomechanical properties, alumina implants are not commercially available any more. Since end of the 1990s, zirconia has been established in dentistry due to its superior biomechanical properties compared to other oxide ceramics such as alumina. Currently, zirconia is the material of choice for the fabrication of ceramic implants. Zirconia implants show superior biocompatibility compared to titanium and other metals. Additionally, it has been reported that zirconia implants with a micro-rough surface topography show at least a comparable osseointegrative capacity and similar clinical survival rates to moderately rough titanium implants. The present case reports a fixed implant-supported reconstruction of a large edentulous space with compromised local bone conditions using new monotype zirconia dental implants with a micro-rough surface topography.
Collapse
|
48
|
Chappuis V, Cavusoglu Y, Gruber R, Kuchler U, Buser D, Bosshardt DD. Osseointegration of Zirconia in the Presence of Multinucleated Giant Cells. Clin Implant Dent Relat Res 2015; 18:686-98. [DOI: 10.1111/cid.12375] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Affiliation(s)
- Vivianne Chappuis
- Department of Oral Surgery and Stomatology; School of Dental Medicine; University of Bern; Bern Switzerland
| | - Yeliz Cavusoglu
- Department of Oral Surgery and Stomatology; School of Dental Medicine; University of Bern; Bern Switzerland
| | - Reinhard Gruber
- Laboratory of Oral Cell Biology; School of Dental Medicine; University of Bern; Bern Switzerland
| | - Ulrike Kuchler
- Department of Oral Surgery and Stomatology; School of Dental Medicine; University of Bern; Bern Switzerland
| | - Daniel Buser
- Department of Oral Surgery and Stomatology; School of Dental Medicine; University of Bern; Bern Switzerland
| | - Dieter D Bosshardt
- Robert K. Schenk Laboratory of Oral Histology; School of Dental Medicine; University of Bern; Bern Switzerland
| |
Collapse
|
49
|
Schwarz F, John G, Hegewald A, Becker J. Non-surgical treatment of peri-implant mucositis and peri-implantitis at zirconia implants: a prospective case series. J Clin Periodontol 2015; 42:783-788. [PMID: 26249545 DOI: 10.1111/jcpe.12439] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/23/2015] [Indexed: 01/01/2023]
Abstract
OBJECTIVES To assess the efficacy of non-surgical therapy for the management of peri-implant diseases at a two-piece zirconium implant system. MATERIAL & METHODS Thirty-four patients with 45 implants participated in this study. Seventeen patients (24 implants) were diagnosed with peri-implant mucositis and received mechanical debridement + local antiseptic therapy using chlorhexidine digluconate (MD + CXH), while 17 patients (21 implants) diagnosed with peri-implantitis were assigned to Er:YAG laser therapy. In both groups, post-operative maintenance care included supramucosal plaque removal and local pocket irrigation using CHX. The primary endpoint was defined as disease resolution at 6 months (i.e. absence of bleeding upon probing (BOP) at mucositis sites/absence of BOP and probing pocket depths (PD) ≥6 mm at peri-implantitis sites). RESULTS Resolution of peri-implant mucositis and peri-implantitis was obtained in 9/17 (52.9%) (p = 0.001) and 5/17 (29.4%) (p = 0.02) of the patients respectively. CONCLUSION Non-surgical treatment of either peri-implant mucositis using MD + CHX or peri-implantitis using ERL at zirconia implants was associated with significant short-term clinical improvements. A complete disease resolution, however, was not achieved in the majority of the patients.
Collapse
Affiliation(s)
- Frank Schwarz
- Department of Oral Surgery, Westdeutsche Kieferklinik, Universitätsklinikum Düsseldorf, Düsseldorf, Germany
| | - Gordon John
- Department of Oral Surgery, Westdeutsche Kieferklinik, Universitätsklinikum Düsseldorf, Düsseldorf, Germany
| | - Andrea Hegewald
- Department of Oral Surgery, Westdeutsche Kieferklinik, Universitätsklinikum Düsseldorf, Düsseldorf, Germany
| | - Jürgen Becker
- Department of Oral Surgery, Westdeutsche Kieferklinik, Universitätsklinikum Düsseldorf, Düsseldorf, Germany
| |
Collapse
|
50
|
Spies B, Balmer M, Patzelt S, Vach K, Kohal R. Clinical and Patient-reported Outcomes of a Zirconia Oral Implant. J Dent Res 2015; 94:1385-91. [DOI: 10.1177/0022034515598962] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
The objective of this study was to determine the clinical, radiographic, and patient-reported outcomes of a 1-piece alumina-toughened zirconia implant restored with single crowns (SCs) or 3-unit fixed dental prostheses (FDPs) after 3 y of observation. Forty patients received 53 implants, placed in a 1-stage operation with immediate temporization. Finally, 50 implants were restored with 24 SCs and 13 FDPs. To evaluate peri-implant bone loss, standardized radiographs were taken at implant insertion, at final restoration delivery, and after 1 and 3 y. Additionally, several soft tissue parameters and patient-reported outcome measures were evaluated. Linear mixed models with random intercept for each patient and patients as clusters were used to compare subgroups. Three patients did not receive a SC due to early implant loss, and 1 patient died. As a result, 36 patients with 49 implants were followed-up for 3 y, giving a cumulative survival rate of 94.2%. The average marginal bone loss amounted to 0.79 mm (SCs, 0.47 mm; FDPs, 1.07 mm; P < 0.001). After the delivery of the final prosthetic restoration, further bone loss was not statistically significant (0.09 mm; P = 0.700). Probing depth, clinical attachment level, and modified bleeding index increased significantly at the implant sites, whereas gingival recession decreased significantly. Compared with the pretreatment questionnaires, the patient-reported outcome measures showed a permanently improved perception of function, aesthetics, sense, speech and self-esteem. The survival rate of the investigated ceramic implant system seems to be comparable to reported survival rates of titanium implants when immediately restored. The recorded parameters suggest its potential for clinical utilization.
Collapse
Affiliation(s)
- B.C. Spies
- Medical Center–University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany
| | - M. Balmer
- Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland
| | - S.B.M. Patzelt
- Medical Center–University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany
| | - K. Vach
- Medical Center–University of Freiburg, Center for Medical Biometry and Medical Informatics, Institute for Medical Biometry and Statistics, Freiburg, Germany
| | - R.J. Kohal
- Medical Center–University of Freiburg, Center for Dental Medicine, Department of Prosthetic Dentistry, Freiburg, Germany
| |
Collapse
|