51
|
Pertegal V, Lacasa E, Cañizares P, Rodrigo MA, Sáez C. Understanding the influence of the bioaerosol source on the distribution of airborne bacteria in hospital indoor air. ENVIRONMENTAL RESEARCH 2023; 216:114458. [PMID: 36181895 DOI: 10.1016/j.envres.2022.114458] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2022] [Revised: 09/22/2022] [Accepted: 09/26/2022] [Indexed: 06/16/2023]
Abstract
The composition and concentration of airborne microorganisms in hospital indoor air has been reported to contain airborne bacteria and fungi concentrations ranged 101-103 CFU/m3 in inpatients facilities which mostly exceed recommendations from the World Health Organization (WHO). In this work, a deeper knowledge of the performance of airborne microorganisms would allow improving the designs of the air-conditioning installations to restrict hospital-acquired infections (HAIs). A solution containing Escherichia coli (E. coli) as a model of airborne bacteria was nebulized using the Collison nebulizer to simulate bioaerosols in various hospital areas such as patients' rooms or bathrooms. Results showed that the bioaerosol source had a significant influence on the airborne bacteria concentrations since 4.00 102, 6.84 103 and 1.39 104 CFU mL-1 were monitored during the aerosolization for 10 min of urine, saliva and urban wastewater, respectively. These results may be explained considering the quite narrow distribution profile of drop sizes around 1.10-1.29 μm obtained for urban wastewater, with much vaster distribution profiles during the aerosolization of urine or saliva. The airborne bacteria concentration may increase up to 107 CFU mL-1 for longer sampling times and higher aerosolization pressures, causing several cell damages. The cell membrane damage index (ID) can vary from 0 to 1, depending on the genomic DNA releases from bacteria. In fact, the ID of E. coli was more than two times higher (0.33 vs. 0.72) when increasing the pressure of air flow was applied from 1 to 2 bar. Finally, the ventilation air flow also affected the distribution of bioaerosols due to its direct relationship with the relative humidity of indoor air. Specifically, the airborne bacteria concentration diminished almost below 3-logs by applying more than 10 L min-1 during the aerosolization of urine due to their inactivation by an increase in their osmotic pressure.
Collapse
Affiliation(s)
- Víctor Pertegal
- Department of Chemical Engineering, Higher Technical School of Industrial Engineering, University of Castilla-La Mancha, Edificio Infante Don Juan Manuel, Campus Universitario S/n, 02071, Albacete, Spain
| | - Engracia Lacasa
- Department of Chemical Engineering, Higher Technical School of Industrial Engineering, University of Castilla-La Mancha, Edificio Infante Don Juan Manuel, Campus Universitario S/n, 02071, Albacete, Spain.
| | - Pablo Cañizares
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Edificio Enrique Costa Novella, Campus Universitario S/n, 13005, Ciudad Real, Spain
| | - Manuel A Rodrigo
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Edificio Enrique Costa Novella, Campus Universitario S/n, 13005, Ciudad Real, Spain
| | - Cristina Sáez
- Department of Chemical Engineering, Faculty of Chemical Sciences and Technologies, University of Castilla-La Mancha, Edificio Enrique Costa Novella, Campus Universitario S/n, 13005, Ciudad Real, Spain.
| |
Collapse
|
52
|
Mahaffee WF, Margairaz F, Ulmer L, Bailey BN, Stoll R. Catching Spores: Linking Epidemiology, Pathogen Biology, and Physics to Ground-Based Airborne Inoculum Monitoring. PLANT DISEASE 2023; 107:13-33. [PMID: 35679849 DOI: 10.1094/pdis-11-21-2570-fe] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Monitoring airborne inoculum is gaining interest as a potential means of giving growers an earlier warning of disease risk in a management unit or region. This information is sought by growers to aid in adapting to changes in the management tools at their disposal and the market-driven need to reduce the use of fungicides and cost of production. To effectively use inoculum monitoring as a decision aid, there is an increasing need to understand the physics of particle transport in managed and natural plant canopies to effectively deploy and use near-ground aerial inoculum data. This understanding, combined with the nuances of pathogen-specific biology and disease epidemiology, can serve as a guide to designing improved monitoring approaches. The complexity of any pathosystem and local environment are such that there is not a generalized approach to near-ground air sampler placement, but there is a conceptual framework to arrive at a "semi-optimal" solution based on available resources. This review is intended as a brief synopsis of the linkages among pathogen biology, disease epidemiology, and the physics of the aerial dispersion of pathogen inoculum and what to consider when deciding where to locate ground-based air samplers. We leverage prior work in developing airborne monitoring tools for hops, grapes, spinach, and turf, and research into the fluid mechanics governing particle transport in sparse canopies and urban and forest environments. We present simulation studies to demonstrate how particles move in the complex environments of agricultural fields and to illustrate the limited sampling area of common air samplers.
Collapse
Affiliation(s)
- Walter F Mahaffee
- United States Department of Agriculture, Agricultural Research Service (USDA-ARS), Corvallis, OR 97330
| | - Fabien Margairaz
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT 84112
| | - Lucas Ulmer
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT 84112
| | - Brian N Bailey
- Department of Plant Sciences, University of California, Davis, Davis, CA 95616
| | - Rob Stoll
- Department of Mechanical Engineering, University of Utah, Salt Lake City, UT 84112
| |
Collapse
|
53
|
Identification of microbial airborne contamination routes in a food production environment and development of a tailored protection concept using computational fluid dynamics (CFD) simulation. J FOOD ENG 2022. [DOI: 10.1016/j.jfoodeng.2022.111157] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
54
|
Li J, Zuraimi S, Schiavon S, Wan MP, Xiong J, Tham KW. Diurnal trends of indoor and outdoor fluorescent biological aerosol particles in a tropical urban area. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 848:157811. [PMID: 35931158 DOI: 10.1016/j.scitotenv.2022.157811] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 07/20/2022] [Accepted: 07/31/2022] [Indexed: 06/15/2023]
Abstract
We evaluated diurnal trends of size-resolved indoor and outdoor fluorescent biological airborne particles (FBAPs) and their contributions to particulate matter (PM) within 0.5-20 μm. After a ten-week continuous sampling via two identical wideband integrated bioaerosol sensors, we found that both indoor and outdoor diurnal trends of PM were driven by its bioaerosol component. Outdoors, the median [interquartile range] FBAP mass concentration peaked at 8.2 [5.8-9.9] μg/m3 around sunrise and showed a downtrend from 6:00 to 18:00 during the daytime and an uptrend during the night. The nighttime FBAP level was 1.8 [1.4-2.2] times higher than that during the daytime, and FBAPs accounted for 45 % and 56 % of PM during daytime and nighttime, respectively. Indoors, the rise in concentrations of FBAPs smaller than 1 μm coincided with the starting operation of the heating, ventilation, and air conditioning (HVAC) system at 6:00, and the concentration peaked at 8:00 and dropped to the daily average by noontime. This indicated that the starting operation of the HVAC system dislodged the overnight settled and accumulated fine bioaerosols into the indoor environment. For particles larger than 1 μm, the variation of mass concentration was driven by occupancy. Based on regression modeling, the contributions of indoor PM, non-FBAP, and FBAP sources to indoor mass concentrations were estimated to be 93 %, 67 %, and 97 % during the occupied period.
Collapse
Affiliation(s)
- Jiayu Li
- Berkeley Education Alliance for Research in Singapore (BEARS), 1 Create Way, 138602, Singapore.
| | - Sultan Zuraimi
- Berkeley Education Alliance for Research in Singapore (BEARS), 1 Create Way, 138602, Singapore
| | - Stefano Schiavon
- Center for the Built Environment (CBE), UC Berkeley, 390 Wurster Hall, Berkeley, CA 94720, USA
| | - Man Pun Wan
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Ave, 639798, Singapore
| | - Jinwen Xiong
- School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Ave, 639798, Singapore
| | - Kwok Wai Tham
- Department of Building, National University of Singapore, 4 Architecture Drive, 117566, Singapore
| |
Collapse
|
55
|
Regan DP, Fong C, Bond ACS, Desjardins C, Hardcastle J, Hung SH, Holmes AP, Schiffman JD, Maginnis MS, Howell C. Improved Recovery of Captured Airborne Bacteria and Viruses with Liquid-Coated Air Filters. ACS APPLIED MATERIALS & INTERFACES 2022; 14:50543-50556. [PMID: 36331290 PMCID: PMC10028737 DOI: 10.1021/acsami.2c14754] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The COVID-19 pandemic has revealed the importance of the detection of airborne pathogens. Here, we present composite air filters featuring a bioinspired liquid coating that facilitates the removal of captured aerosolized bacteria and viruses for further analysis. We tested three types of air filters: commercial polytetrafluoroethylene (PTFE), which is well known for creating stable liquid coatings, commercial high-efficiency particulate air (HEPA) filters, which are widely used, and in-house-manufactured cellulose nanofiber mats (CNFMs), which are made from sustainable materials. All filters were coated with omniphobic fluorinated liquid to maximize the release of pathogens. We found that coating both the PTFE and HEPA filters with liquid improved the rate at which Escherichia coli was recovered using a physical removal process compared to uncoated controls. Notably, the coated HEPA filters also increased the total number of recovered cells by 57%. Coating the CNFM filters did not improve either the rate of release or the total number of captured cells. The most promising materials, the liquid-coated HEPA, filters were then evaluated for their ability to facilitate the removal of pathogenic viruses via a chemical removal process. Recovery of infectious JC polyomavirus, a nonenveloped virus that attacks the central nervous system, was increased by 92% over uncoated controls; however, there was no significant difference in the total amount of genomic material recovered compared to that of controls. In contrast, significantly more genomic material was recovered for SARS-CoV-2, the airborne, enveloped virus, which causes COVID-19, from liquid-coated filters. Although the amount of infectious SARS-CoV-2 recovered was 58% higher, these results were not significantly different from uncoated filters due to high variability. These results suggest that the efficient recovery of airborne pathogens from liquid-coated filters could improve air sampling efforts, enhancing biosurveillance and global pathogen early warning.
Collapse
Affiliation(s)
- Daniel P Regan
- Department of Chemical and Biomedical Engineering, University of Maine, 5737 Jenness Hall, Orono, Maine04469, United States
- Graduate School of Biomedical Science and Engineering, University of Maine, 42 Stodder Hall, Orono, Maine04469, United States
| | - ChunKi Fong
- Graduate School of Biomedical Science and Engineering, University of Maine, 42 Stodder Hall, Orono, Maine04469, United States
| | - Avery C S Bond
- Department of Molecular and Biomedical Sciences, University of Maine, 320 Hitchner Hall, Orono, Maine04469, United States
| | - Claudia Desjardins
- Department of Molecular and Biomedical Sciences, University of Maine, 320 Hitchner Hall, Orono, Maine04469, United States
| | - Justin Hardcastle
- Graduate School of Biomedical Science and Engineering, University of Maine, 42 Stodder Hall, Orono, Maine04469, United States
| | - Shao-Hsiang Hung
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts01003-9303, United States
| | - Andrew P Holmes
- Cooperative Extension, University of Maine, 17 Godfrey Drive, Orono, Maine04473, United States
| | - Jessica D Schiffman
- Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts01003-9303, United States
| | - Melissa S Maginnis
- Graduate School of Biomedical Science and Engineering, University of Maine, 42 Stodder Hall, Orono, Maine04469, United States
- Department of Molecular and Biomedical Sciences, University of Maine, 320 Hitchner Hall, Orono, Maine04469, United States
| | - Caitlin Howell
- Department of Chemical and Biomedical Engineering, University of Maine, 5737 Jenness Hall, Orono, Maine04469, United States
- Graduate School of Biomedical Science and Engineering, University of Maine, 42 Stodder Hall, Orono, Maine04469, United States
| |
Collapse
|
56
|
Yu L. Real-time monitoring of air pathogens in the ICU with biosensors and robots. Crit Care 2022; 26:353. [PMCID: PMC9662127 DOI: 10.1186/s13054-022-04222-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Accepted: 10/28/2022] [Indexed: 11/16/2022] Open
|
57
|
Tian J, Yan C, Alcega SG, Hassard F, Tyrrel S, Coulon F, Nasir ZA. Detection and characterization of bioaerosol emissions from wastewater treatment plants: Challenges and opportunities. Front Microbiol 2022; 13:958514. [PMID: 36439798 PMCID: PMC9684734 DOI: 10.3389/fmicb.2022.958514] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 10/11/2022] [Indexed: 09/04/2023] Open
Abstract
Rapid population growth and urbanization process have led to increasing demand for wastewater treatment capacity resulting in a non-negligible increase of wastewater treatment plants (WWTPs) in several cities around the world. Bioaerosol emissions from WWTPs may pose adverse health risks to the sewage workers and nearby residents, which raises increasing public health concerns. However, there are still significant knowledge gaps on the interplay between process-based bioaerosol characteristics and exposures and the quantification of health risk which limit our ability to design effective risk assessment and management strategies. This review provides a critical overview of the existing knowledge of bioaerosol emissions from WWTPs including their nature, magnitude and size distribution, and highlights the shortcoming associated with existing sampling and analysis methods. The recent advancements made for rapid detection of bioaerosols are then discussed, especially the emerging real time detection methods to highlight the directions for future research needs to advance the knowledge on bioaerosol emissions from WWTPs.
Collapse
Affiliation(s)
- Jianghan Tian
- School of Chemistry, University of Bristol, Bristol, United Kingdom
| | - Cheng Yan
- School of Water, Energy and Environment, Cranfield University, Cranfield, United Kingdom
- School of Environmental Studies, China University of Geosciences, Wuhan, China
| | - Sonia Garcia Alcega
- School of Physical Sciences, The Open University, Walton Hall, Milton Keynes, United Kingdom
| | - Francis Hassard
- School of Water, Energy and Environment, Cranfield University, Cranfield, United Kingdom
- Institute for Nanotechnology and Water Sustainability, University of South Africa, Johannesburg, South Africa
| | - Sean Tyrrel
- School of Water, Energy and Environment, Cranfield University, Cranfield, United Kingdom
| | - Frederic Coulon
- School of Water, Energy and Environment, Cranfield University, Cranfield, United Kingdom
| | - Zaheer Ahmad Nasir
- School of Water, Energy and Environment, Cranfield University, Cranfield, United Kingdom
| |
Collapse
|
58
|
Semeraro S, Gaetano AS, Zupin L, Poloni C, Merlach E, Greco E, Licen S, Fontana F, Leo S, Miani A, Broccolo F, Barbieri P. Operative Protocol for Testing the Efficacy of Nasal Filters in Preventing Airborne Transmission of SARS-CoV-2. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:13790. [PMID: 36360670 PMCID: PMC9654745 DOI: 10.3390/ijerph192113790] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 10/18/2022] [Accepted: 10/19/2022] [Indexed: 06/16/2023]
Abstract
BACKGROUND Standardized methods for testing Viral Filtration Efficiency (VFE) of tissues and devices are lacking and few studies are available on aerosolizing, sampling and assessing infectivity of SARS-CoV-2 in controlled laboratory settings. NanoAg-coated endonasal filters appear a promising aid for lowering viable virus inhalation in both adult and younger populations (e.g., adolescents). OBJECTIVE to provide an adequate method for testing SARS-CoV-2 bioaerosol VFE of bio-gel Ag nanoparticles endonasal filters, by a model system, assessing residual infectivity as cytopathic effect and viral proliferation on in vitro cell cultures. METHODS A SARS-CoV-2 aerosol transmission chamber fed by a BLAM aerosol generator produces challenges (from very high viral loads (105 PFU/mL) to lower ones) for endonasal filters positioned in a Y shape sampling port connected to a Biosampler. An aerosol generator, chamber and sampler are contained in a class II cabinet in a BSL3 facility. Residual infectivity is assessed from aliquots of liquid collecting bioaerosol, sampled without and with endonasal filters. Cytopathic effect as plaque formation and viral proliferation assessed by qRT-PCR on Vero E6 cells are determined up to 7 days post inoculum. RESULTS Each experimental setting is replicated three times and basic statistics are calculated. Efficiency of aerosolization is determined as difference between viral load in the nebulizer and in the Biosampler at the first day of experiment. Efficiency of virus filtration is calculated as RNA viral load ratio in collected bioaerosol with and without endonasal filters at the day of the experiment. Presence of infectious virus is assessed by plaque forming unit assay and RNA viral load variations. CONCLUSIONS A procedure and apparatus for assessing SARS-CoV-2 VFE for endonasal filters is proposed. The apparatus can be implemented for more sophisticated studies on contaminated aerosols.
Collapse
Affiliation(s)
- Sabrina Semeraro
- INSTM National Interuniversity Consortium of Materials Science and Technology, Research Unit of University of Trieste, 34127 Trieste, Italy
| | - Anastasia Serena Gaetano
- INSTM National Interuniversity Consortium of Materials Science and Technology, Research Unit of University of Trieste, 34127 Trieste, Italy
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgieri 1, 34127 Trieste, Italy
| | - Luisa Zupin
- Institute for Maternal and Child Health, IRCCS Burlo Garofolo, Via dell’Istria 65/1, 34137 Trieste, Italy
| | - Carlo Poloni
- INSTM National Interuniversity Consortium of Materials Science and Technology, Research Unit of University of Trieste, 34127 Trieste, Italy
- Department of Engineering and Architecture, University of Trieste, Via A. Valerio 10, 34127 Trieste, Italy
| | - Elvio Merlach
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgieri 1, 34127 Trieste, Italy
| | - Enrico Greco
- INSTM National Interuniversity Consortium of Materials Science and Technology, Research Unit of University of Trieste, 34127 Trieste, Italy
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgieri 1, 34127 Trieste, Italy
- SIMA Società Italiana di Medicina Ambientale, Viale di Porta Vercellina, 9, 20123 Milano, Italy
| | - Sabina Licen
- INSTM National Interuniversity Consortium of Materials Science and Technology, Research Unit of University of Trieste, 34127 Trieste, Italy
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgieri 1, 34127 Trieste, Italy
| | - Francesco Fontana
- Ospedale San Polo, Azienda Sanitaria Universitaria Giuliano Isontina, Via Luigi Galvani 1, 34074 Monfalcone, Italy
| | - Silvana Leo
- Division of Oncology, Vito Fazzi Hospital, P.za Muratore 1, 73100 Lecce, Italy
| | - Alessandro Miani
- SIMA Società Italiana di Medicina Ambientale, Viale di Porta Vercellina, 9, 20123 Milano, Italy
- Department of Environmental Science and Policy, University of Milan, Via Festa del Perdono 7, 20122 Milano, Italy
| | - Francesco Broccolo
- SIMA Società Italiana di Medicina Ambientale, Viale di Porta Vercellina, 9, 20123 Milano, Italy
- Department of Medicine and Surgery, School of Medicine, University of Milano-Bicocca, 20900 Monza, Italy
- Cerba HealthCare Italia, Via Durini, 14, 20122 Milano, Italy
| | - Pierluigi Barbieri
- INSTM National Interuniversity Consortium of Materials Science and Technology, Research Unit of University of Trieste, 34127 Trieste, Italy
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgieri 1, 34127 Trieste, Italy
- SIMA Società Italiana di Medicina Ambientale, Viale di Porta Vercellina, 9, 20123 Milano, Italy
| |
Collapse
|
59
|
Chow JC, Watson JG, Wang X, Abbasi B, Reed WR, Parks D. Review of Filters for Air Sampling and Chemical Analysis in Mining Workplaces. MINERALS (BASEL, SWITZERLAND) 2022; 12:10.3390/min12101314. [PMID: 37180428 PMCID: PMC10174218 DOI: 10.3390/min12101314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
This review considers the use of filters to sample air in mining workplace environments for dust concentration measurement and subsequent analysis of hazardous contaminants, especially respirable crystalline silica (RCS) on filters compatible with wearable personal dust monitors (PDM). The review summarizes filter vendors, sizes, costs, chemical and physical properties, and information available on filter modeling, laboratory testing, and field performance. Filter media testing and selection should consider the characteristics required for mass by gravimetry in addition to RCS quantification by Fourier-transform infrared (FTIR) or Raman spectroscopic analysis. For mass determination, the filters need to have high filtration efficiency (≥99% for the most penetrable particle sizes) and a reasonable pressure drop (up to 16.7 kPa) to accommodate high dust loading. Additional requirements include: negligible uptake of water vapor and gaseous volatile compounds; adequate particle adhesion as a function of particle loading; sufficient particle loading capacity to form a stable particle deposit layer during sampling in wet and dusty environments; mechanical strength to withstand vibrations and pressure drops across the filter; and appropriate filter mass compatible with the tapered element oscillating microbalance. FTIR and Raman measurements require filters to be free of spectral interference. Furthermore, because the irradiated area does not completely cover the sample deposit, particles should be uniformly deposited on the filter.
Collapse
Affiliation(s)
- Judith C. Chow
- Division of Atmospheric Sciences, Desert Research Institute, Reno, NV 89511, USA
- Correspondence:
| | - John G. Watson
- Division of Atmospheric Sciences, Desert Research Institute, Reno, NV 89511, USA
| | - Xiaoliang Wang
- Division of Atmospheric Sciences, Desert Research Institute, Reno, NV 89511, USA
| | - Behrooz Abbasi
- Department of Mining and Metallurgical Engineering, University of Nevada, Reno, NV 89557, USA
| | - Wm. Randolph Reed
- Office of the Director, National Institute for Occupational Safety and Health, Pittsburgh, PA 15236, USA
| | - David Parks
- Spokane Mining Research Division, National Institute for Occupational Safety and Health, Spokane, WA 99207, USA
| |
Collapse
|
60
|
Grogan SN, Han TT, Mainelis G. Development and initial testing of an active low-power, ferroelectric film-based bioaerosol sampler. AEROSOL SCIENCE AND TECHNOLOGY : THE JOURNAL OF THE AMERICAN ASSOCIATION FOR AEROSOL RESEARCH 2022; 56:1132-1145. [PMID: 37168518 PMCID: PMC10168024 DOI: 10.1080/02786826.2022.2128985] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Accepted: 09/15/2022] [Indexed: 05/13/2023]
Abstract
This article introduces REAS (Rutgers Electrostatic Active Sampler), a new active bioaerosol sampler using permanently polarized ferroelectric film (e.g., PVDF) to capture charge-carrying bioaerosol particles. While REAS operates on an electrostatic collection principle, due to its unique materials and design, it does not require external power to charge incoming particles or to create an electrostatic collection field. The sampler consists of a polarized film wound in a spiral configuration with oppositely polarized film sides positioned 2.25 mm apart. The film and its holder are inserted into a 3D-printed housing cylinder to connect to a pump. The device has an open channel design, creating virtually no pressure drop, which allows for longer sampling times on the same battery charge compared to filter samplers. When REAS was tested in different field environments, the physical collection efficiency ranged from 19 ± 2% in a laboratory environment at 1 L/min to 41 ± 0.1% in residence at 0.1 L/min. When REAS was used to capture culturable bacteria and fungi over a 24-hr period, the concentrations determined by REAS were not different from those determined by an Institute of Medicine sampler (IOM, SKC, Inc.). The concentrations determined by both samplers were lower than those measured by a SAS Super 180 Sampler (SAS, Bioscience International), except for outdoor fungi. However, the SAS was used as a grab sampler to avoid overloading or desiccating the plates, while both REAS and IOM continuously sampled for 24 hrs. Further studies will explore improvements to the REAS sample elution protocols.
Collapse
Affiliation(s)
- Sydonia N.C.M. Grogan
- Department of Environmental Sciences, Rutgers, The State University of New Jersey, New Brunswick, New Jersey, USA
- Current affiliation: Population Health Sciences, School of Public Health, Georgia State University, Atlanta, Georgia, USA
| | - Taewon T. Han
- Department of Environmental Sciences, Rutgers, The State University of New Jersey, New Brunswick, New Jersey, USA
| | - Gediminas Mainelis
- Department of Environmental Sciences, Rutgers, The State University of New Jersey, New Brunswick, New Jersey, USA
| |
Collapse
|
61
|
Development of aptamers for rapid airborne bacteria detection. Anal Bioanal Chem 2022; 414:7763-7771. [PMID: 36071267 DOI: 10.1007/s00216-022-04308-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 08/11/2022] [Accepted: 08/27/2022] [Indexed: 11/01/2022]
Abstract
Airborne microbes can rapidly spread and cause various infectious diseases worldwide. This necessitates the determination of a fast and highly sensitive detection method. There have been no studies on receptors targeting Citrobacter braakii (C. braakii), a pathogenic bacterium which can exist in the air. In this study, we rapidly isolate an aptamer, a nucleic acid molecule that can specifically bind to C. braakii by centrifugation-based partitioning method (CBPM) reported previously by our groups as omitting the repeated rounds of binding incubation, separation, and amplification that are indispensable for SELEX. The binding affinity and specificity of isolated aptamers are checked using bacteria in liquid culture and recollection solution from aerosolized bacteria. Recollection solutions of the recovered bacteria are obtained by nebulizing, drying, and recapturing with a biosampler. The CB-5 aptamer shows high affinity and specificity for C. braakii (Kd: 16.42 in liquid culture and 26.91 nM in recollection from aerosolized sample). Our results indicate the current protocol can be employed for the rapid development of reliable diagnostic receptors targeting airborne bacteria.
Collapse
|
62
|
Rajaei Ramsheh M, Mahdi Doroodmand M. Novel analytical method based on Fourier Transform assisted Ultraviolet-Infrared dual resonance spectroscopy for aerosol speciation. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
63
|
Shen H, Han M, Shen Y, Shuai D. Electrospun Nanofibrous Membranes for Controlling Airborne Viruses: Present Status, Standardization of Aerosol Filtration Tests, and Future Development. ACS ENVIRONMENTAL AU 2022; 2:290-309. [PMID: 35928556 PMCID: PMC9342653 DOI: 10.1021/acsenvironau.1c00047] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The global COVID-19 pandemic has raised great public concern about the airborne transmission of viral pathogens. Virus-laden aerosols with small size could be suspended in the air for a long duration and remain infectious. Among a series of measures implemented to mitigate the airborne spread of infectious diseases, filtration by face masks, respirators, and air filters is a potent nonpharmacologic intervention. Compared with conventional air filtration media, nanofibrous membranes fabricated via electrospinning are promising candidates for controlling airborne viruses due to their desired characteristics, i.e., a reduced pore size (submicrometers to several micrometers), a larger specific surface area and porosity, and retained surface and volume charges. So far, a wide variety of electrospun nanofibrous membranes have been developed for aerosol filtration, and they have shown excellent filtration performance. However, current studies using electrospinning for controlling airborne viruses vary significantly in the practice of aerosol filtration tests, including setup configurations and operations. The discrepancy among various studies makes it difficult, if not impossible, to compare filtration performance. Therefore, there is a pressing need to establish a standardized protocol for evaluating the electrospun nanofibrous membranes' performance for removing viral aerosols. In this perspective, we first reviewed the properties and performance of diverse filter media, including electrospun nanofibrous membranes, for removing viral aerosols. Next, aerosol filtration protocols for electrospun nanofibrous membranes were discussed with respect to the aerosol generation, filtration, collection, and detection. Thereafter, standardizing the aerosol filtration test system for electrospun nanofibrous membranes was proposed. In the end, the future advancement of electrospun nanofibrous membranes for enhanced air filtration was discussed. This perspective provides a comprehensive understanding of status and challenges of electrospinning for air filtration, and it sheds light on future nanomaterial and protocol development for controlling airborne viruses, preventing the spread of infectious diseases, and beyond.
Collapse
Affiliation(s)
- Hongchen Shen
- Department
of Civil and Environmental Engineering, The George Washington University, Washington, DC 20052, United States
| | - Minghao Han
- Department
of Chemical and Environmental Engineering, University of California, Riverside, Riverside, California 92521, United States
| | - Yun Shen
- Department
of Chemical and Environmental Engineering, University of California, Riverside, Riverside, California 92521, United States
| | - Danmeng Shuai
- Department
of Civil and Environmental Engineering, The George Washington University, Washington, DC 20052, United States
| |
Collapse
|
64
|
Kormos D, Lin K, Pruden A, Marr LC. Critical review of antibiotic resistance genes in the atmosphere. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2022; 24:870-883. [PMID: 35638569 DOI: 10.1039/d2em00091a] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
We conducted a critical review to establish what is known about the sources, characteristics, and dissemination of ARGs in the atmosphere. We identified 52 papers that reported direct measurements of bacterial ARGs in air samples and met other inclusion criteria. The settings of the studies fell into the following categories: urban, rural, hospital, industrial, wastewater treatment plants (WWTPs), composting and landfill sites, and indoor environments. Certain genes were commonly studied and generally abundant: sul1, intI1, β-lactam ARGs, and tetracycline ARGs. Abundances of total ARGs varied by season and setting, with air in urban areas having higher ARG abundance than rural areas during the summer and vice versa during the winter. There was greater consistency in the types and abundances of ARGs throughout the seasons in urban areas. Human activity within indoor environments was also linked to increased ARG content (abundance, diversity, and concentration) in the air. Several studies found that human exposure to ARGs through inhalation was comparable to exposure through drinking water or ingesting soil. Detection of ARGs in air is a developing field, and differences in sampling and analysis methods reflect the many possible approaches to studying ARGs in air and make direct comparisons between studies difficult. Methodologies need to be standardized to facilitate identification of the dominant ARGs in the air, determine their major sources, and quantify the role of atmospheric transport in dissemination of ARGs in the environment. With such knowledge we can develop better policies and guidelines to limit the spread of antimicrobial resistance.
Collapse
Affiliation(s)
- David Kormos
- Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, USA.
| | - Kaisen Lin
- Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, USA.
| | - Amy Pruden
- Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, USA.
| | - Linsey C Marr
- Civil and Environmental Engineering, Virginia Tech, Blacksburg, VA, USA.
| |
Collapse
|
65
|
Manibusan S, Mainelis G. Passive Bioaerosol Samplers: A Complementary Tool for Bioaerosol Research. A Review. JOURNAL OF AEROSOL SCIENCE 2022; 163:105992. [PMID: 36386279 PMCID: PMC9648171 DOI: 10.1016/j.jaerosci.2022.105992] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Bioaerosols consist of airborne particles of biological origin. They play an important role in our environment and may cause negative health effects. The presence of biological aerosol is typically determined using active samplers. While passive bioaerosol samplers are used much less frequently in bioaerosol investigations, they offer certain advantages, such as simple design, low cost, and long sampling duration. This review discusses different types of passive bioaerosol samplers, including their collection mechanisms, advantages and disadvantages, applicability in different sampling environments, and available sample elution and analysis methods. Most passive samplers are based on gravitational settling and electrostatic capture mechanism or their combination. We discuss the agar settle plate, dustfall collector, Personal Aeroallergen Sampler (PAAS), and settling filters among the gravity-based samplers. The described electrostatics-based samplers include electrostatic dust cloths (EDC) and Rutgers Electrostatic Passive Sampler (REPS). In addition, the review also discusses passive opportunity samplers using preexisting airflow, such as filters in HVAC systems. Overall, passive bioaerosol sampling technologies are inexpensive, easy to operate, and can continuously sample for days and even weeks which is not easily accomplished by active sampling devices. Although passive sampling devices are usually treated as qualitative tools, they still provide information about bioaerosol presence and diversity, especially over longer time scales. Overall, this review suggests that the use of passive bioaerosol samplers alongside active collection devices can aid researchers in developing a more comprehensive understanding of biological presence and dynamics, especially over extended time scales and multiple locations.
Collapse
Affiliation(s)
- Sydonia Manibusan
- Department of Environmental Sciences, Rutgers, The State University of New Jersey, 14 College Farm Road, New Brunswick, New Jersey 08901-8551, USA
| | - Gediminas Mainelis
- Department of Environmental Sciences, Rutgers, The State University of New Jersey, 14 College Farm Road, New Brunswick, New Jersey 08901-8551, USA
| |
Collapse
|
66
|
Brown E, Nelson N, Gubbins S, Colenutt C. Airborne Transmission of Foot-and-Mouth Disease Virus: A Review of Past and Present Perspectives. Viruses 2022; 14:1009. [PMID: 35632750 PMCID: PMC9145556 DOI: 10.3390/v14051009] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 04/25/2022] [Accepted: 05/05/2022] [Indexed: 02/01/2023] Open
Abstract
The primary transmission route for foot-and-mouth disease (FMD), a contagious viral disease of cloven-hoofed animals, is by direct contact with infected animals. Yet indirect methods of transmission, such as via the airborne route, have been shown to play an important role in the spread of the disease. Airborne transmission of FMD is referred to as a low probability- high consequence event as a specific set of factors need to coincide to facilitate airborne spread. When conditions are favourable, airborne virus may spread rapidly and cause disease beyond the imposed quarantine zones, thus complicating control measures. Therefore, it is important to understand the nature of foot-and-mouth disease virus (FMDV) within aerosols; how aerosols are generated, viral load, how far aerosols could travel and survive under different conditions. Various studies have investigated emissions from infected animals under laboratory conditions, while others have incorporated experimental data in mathematical models to predict and trace outbreaks of FMD. However, much of the existing literature focussing on FMDV in aerosols describe work which was undertaken over 40 years ago. The aim of this review is to revisit existing knowledge and investigate how modern instrumentation and modelling approaches can improve our understanding of airborne transmission of FMD.
Collapse
Affiliation(s)
- Emma Brown
- The Pirbright Institute, Ash Road, Pirbright, Surrey GU24 0NF, UK; (S.G.); (C.C.)
| | - Noel Nelson
- The Met Office, FitzRoy Road, Exeter, Devon EX1 3PB, UK;
| | - Simon Gubbins
- The Pirbright Institute, Ash Road, Pirbright, Surrey GU24 0NF, UK; (S.G.); (C.C.)
| | - Claire Colenutt
- The Pirbright Institute, Ash Road, Pirbright, Surrey GU24 0NF, UK; (S.G.); (C.C.)
| |
Collapse
|
67
|
Anees-Hill S, Douglas P, Pashley CH, Hansell A, Marczylo EL. A systematic review of outdoor airborne fungal spore seasonality across Europe and the implications for health. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 818:151716. [PMID: 34800445 PMCID: PMC8919338 DOI: 10.1016/j.scitotenv.2021.151716] [Citation(s) in RCA: 42] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 11/08/2021] [Accepted: 11/12/2021] [Indexed: 05/08/2023]
Abstract
Fungal spores make up a significant proportion of organic matter within the air. Allergic sensitisation to fungi is associated with conditions including allergic fungal airway disease. This systematic review analyses outdoor fungal spore seasonality across Europe and considers the implications for health. Seventy-four studies met the inclusion criteria, the majority of which (n = 64) were observational sampling studies published between 1978 and 2020. The most commonly reported genera were the known allergens Alternaria and Cladosporium, measured in 52 and 49 studies, respectively. Both displayed statistically significant increased season length in south-westerly (Mediterranean) versus north-easterly (Atlantic and Continental) regions. Although there was a trend for reduced peak or annual Alternaria and Cladosporium spore concentrations in more northernly locations, this was not statistically significant. Peak spore concentrations of Alternaria and Cladosporium exceeded clinical thresholds in nearly all locations, with median peak concentrations of 665 and 18,827 per m3, respectively. Meteorological variables, predominantly temperature, precipitation and relative humidity, were the main factors associated with fungal seasonality. Land-use was identified as another important factor, particularly proximity to agricultural and coastal areas. While correlations of increased season length or decreased annual spore concentrations with increasing average temperatures were reported in multi-decade sampling studies, the number of such studies was too small to make any definitive conclusions. Further, up-to-date studies covering underrepresented geographical regions and fungal taxa (including the use of modern molecular techniques), and the impact of land-use and climate change will help address remaining knowledge gaps. Such knowledge will help to better understand fungal allergy, develop improved fungal spore calendars and forecasts with greater geographical coverage, and promote increased awareness and management strategies for those with allergic fungal disease.
Collapse
Affiliation(s)
- Samuel Anees-Hill
- Centre for Environmental Health and Sustainability, University of Leicester, Leicester LE1 7LW, UK; The National Institute of Health Research Health Protection Research Unit in Environmental Exposures and Health, University of Leicester, Leicester LE1 7LW, UK.
| | - Philippa Douglas
- The National Institute of Health Research Health Protection Research Unit in Environmental Exposures and Health, University of Leicester, Leicester LE1 7LW, UK; Environmental Hazards and Emergencies Department, UK Health Security Agency, Harwell Campus, Chilton, Oxfordshire OX11 0RQ, UK.
| | - Catherine H Pashley
- The National Institute of Health Research Health Protection Research Unit in Environmental Exposures and Health, University of Leicester, Leicester LE1 7LW, UK; Department of Respiratory Sciences, Institute for Lung Health, University of Leicester, Leicester LE1 7RH, UK.
| | - Anna Hansell
- Centre for Environmental Health and Sustainability, University of Leicester, Leicester LE1 7LW, UK; The National Institute of Health Research Health Protection Research Unit in Environmental Exposures and Health, University of Leicester, Leicester LE1 7LW, UK.
| | - Emma L Marczylo
- The National Institute of Health Research Health Protection Research Unit in Environmental Exposures and Health, University of Leicester, Leicester LE1 7LW, UK; Toxicology Department, UK Health Security Agency, Harwell Campus, Chilton, Oxfordshire OX11 0RQ, UK.
| |
Collapse
|
68
|
Yeh KB, Setser B. Aerosol Test Chambers: Current State and Practice During the COVID-19 Pandemic. Front Bioeng Biotechnol 2022; 10:863954. [PMID: 35497330 PMCID: PMC9039174 DOI: 10.3389/fbioe.2022.863954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Accepted: 03/25/2022] [Indexed: 11/13/2022] Open
Abstract
Respiratory infectious disease outbreaks such as those caused by coronaviruses and influenza, necessitate the use of specialized aerosol test chambers to study aspects of these causative agents including detection, efficacy of countermeasures, and aerosol survivability. The anthrax attacks from 2001 and earlier biowarfare and biodefense also influenced the study of biological aerosols to learn about how certain pathogens transmit either naturally or through artificial means. Some high containment biological laboratories, which work with Risk Group 3 and 4 agents in biosafety level -3, biosafety level-4 containment, are equipped with aerosol test chambers to enable the study of high-risk organisms in aerosolized form. Consequently, the biomedical, military and environmental sectors have specific applications when studying bioaerosols which may overlap while being different. There are countless aerosol test chambers worldwide and this number along with numerous high containment biological laboratories underscores the need for technical standards, regulatory and dual-use compliance. Here we survey common aerosol test chambers and their history, current use, and practice. Our findings reinforce the importance and need for continued collaboration among the multi-disciplinary fields studying aerobiology and biological aerosols.
Collapse
Affiliation(s)
- Kenneth B. Yeh
- MRIGlobal, Kansas City, MO, United States
- *Correspondence: Kenneth B. Yeh,
| | | |
Collapse
|
69
|
Guo J, Zheng X, Qin T, Lv M, Zhang W, Song X, Qiu H, Hu L, Zhang L, Zhou D, Sun Y, Yang W. An experimental method for efficiently evaluating the size-resolved sampling efficiency of liquid-absorption aerosol samplers. Sci Rep 2022; 12:4745. [PMID: 35304534 PMCID: PMC8932469 DOI: 10.1038/s41598-022-08718-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2021] [Accepted: 03/11/2022] [Indexed: 11/13/2022] Open
Abstract
Aerosol samplers are critical tools for studying indoor and outdoor aerosols. Development and evaluation of samplers is often labor-intensive and time-consuming due to the need to use monodisperse aerosols spanning a range of sizes. This study develops a rapid experimental methodology using polydisperse solid aerosols to evaluate size-resolved aerosol-to-aerosol (AtoA) and aerosol-to-hydrosol (AtoH) sampling efficiencies. Arizona Test Dust (diameter 0.5-20 µm) was generated and dispersed into an aerosol test chamber and two candidate samplers were tested. For the AtoA test, aerosols upstream and downstream of a sampler were measured using an online aerodynamic particle sizer. For the AtoH test, aerosols collected in sampling medium were mixed with a reference sample and then measured by the laser diffraction method. The experimental methodology were validated as an impressive time-saving procedure, with reasonable spatial uniformity and time stability of aerosols in the test chamber and an acceptable accuracy of absolute mass quantification of collected particles. Evaluation results showed that the AGI-30 and the BioSampler sampler had similar size-resolved sampling efficiencies and that efficiencies decreased with decreasing sampling flow rate. The combined evaluation of AtoA and AtoH efficiency provided more comprehensive performance indicators than either test alone. The experimental methodology presented here can facilitate the design and choice of aerosol sampler.
Collapse
Affiliation(s)
- Jianshu Guo
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China
| | - Xinying Zheng
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China
| | - Tongtong Qin
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China
- Laboratory Animal Center, Academy of Military Medical Science, Beijing, China
| | - Meng Lv
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China
| | - Wei Zhang
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China
| | - Xiaolin Song
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China
| | - Hongying Qiu
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China
| | - Lingfei Hu
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China
| | - Lili Zhang
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China
| | - Dongsheng Zhou
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China
| | - Yansong Sun
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China.
| | - Wenhui Yang
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, Beijing, 100071, China.
| |
Collapse
|
70
|
Lee G, Yoo K. A review of the emergence of antibiotic resistance in bioaerosols and its monitoring methods. RE/VIEWS IN ENVIRONMENTAL SCIENCE AND BIO/TECHNOLOGY 2022; 21:799-827. [PMID: 35694630 PMCID: PMC9169023 DOI: 10.1007/s11157-022-09622-3] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2022] [Accepted: 04/30/2022] [Indexed: 04/18/2023]
Abstract
Despite significant public health concerns regarding infectious diseases in air environments, potentially harmful microbiological indicators, such as antibiotic resistance genes (ARGs) in bioaerosols, have not received significant attention. Traditionally, bioaerosol studies have focused on the characterization of microbial communities; however, a more serious problem has recently arisen due to the presence of ARGs in bioaerosols, leading to an increased prevalence of horizontal gene transfer (HGT). This constitutes a process by which bacteria transfer genes to other environmental media and consequently cause infectious disease. Antibiotic resistance in water and soil environments has been extensively investigated in the past few years by applying advanced molecular and biotechnological methods. However, ARGs in bioaerosols have not received much attention. In addition, ARG and HGT profiling in air environments is greatly limited in field studies due to the absence of suitable methodological approaches. Therefore, this study comprehensively describes recent findings from published studies and some of the appropriate molecular and biotechnological methods for monitoring antibiotic resistance in bioaerosols. In addition, this review discusses the main knowledge gaps regarding current methodological issues and future research directions.
Collapse
Affiliation(s)
- Gihan Lee
- Department of Environmental Engineering, Korea Maritime and Ocean University, Busan, 49112 South Korea
- Interdisciplinary Major of Ocean Renewable Energy Engineering, Korea Maritime and Ocean University, Busan, 49112 South Korea
| | - Keunje Yoo
- Department of Environmental Engineering, Korea Maritime and Ocean University, Busan, 49112 South Korea
| |
Collapse
|
71
|
Compendium of analytical methods for sampling, characterization and quantification of bioaerosols. ADV ECOL RES 2022. [DOI: 10.1016/bs.aecr.2022.09.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
72
|
Bora M, M M, Mathew DD, Das H, Bora DP, Barman NN. Point of care diagnostics and non-invasive sampling strategy: a review on major advances in veterinary diagnostics. ACTA VET BRNO 2022; 91:17-34. [DOI: 10.2754/avb202291010017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2025]
Abstract
The use of point of care diagnostics (POCD) in animal diseases has steadily increased over the years since its introduction. Its potential application to diagnose infectious diseases in remote and resource limited settings have made it an ideal diagnostic in animal disease diagnosis and surveillance. The rapid increase in incidence of emerging infectious diseases requires urgent attention where POCD could be indispensable tools for immediate detection and early warning of a potential pathogen. The advantages of being rapid, easily affordable and the ability to diagnose an infectious disease on spot has driven an intense effort to refine and build on the existing technologies to generate advanced POCD with incremental improvements in analytical performance to diagnose a broad spectrum of animal diseases. The rural communities in developing countries are invariably affected by the burden of infectious animal diseases due to limited access to diagnostics and animal health personnel. Besides, the alarming trend of emerging and transboundary diseases with pathogen spill-overs at livestock-wildlife interfaces has been identified as a threat to the domestic population and wildlife conservation. Under such circumstances, POCD coupled with non-invasive sampling techniques could be successfully deployed at field level without the use of sophisticated laboratory infrastructures. This review illustrates the current and prospective POCD for existing and emerging animal diseases, the status of non-invasive sampling strategies for animal diseases, and the tremendous potential of POCD to uplift the status of global animal health care.
Collapse
|
73
|
Investigation of Sources, Diversity, and Variability of Bacterial Aerosols in Athens, Greece: A Pilot Study. ATMOSPHERE 2021. [DOI: 10.3390/atmos13010045] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
We characterized the composition, diversity, and potential bacterial aerosol sources in Athens’ urban air by DNA barcoding (analysis of 16S rRNA genes) during three seasons in 2019. Air samples were collected using the recently developed Rutgers Electrostatic Passive Sampler (REPS). It is the first field application of REPS to study bacterial aerosol diversity. REPS samplers captured a sufficient amount of biological material to demonstrate the diversity of airborne bacteria and their variability over time. Overall, in the air of Athens, we detected 793 operational taxonomic units (OTUs), which were fully classified into the six distinct taxonomic categories (Phylum, Class, Order, etc.). These OTUs belonged to Phyla Actinobacteria, Firmicutes, Proteobacteria, Bacteroidetes, Cyanobacteria, and Fusobacteria. We found a complex community of bacterial aerosols with several opportunistic or potential pathogens in Athens’ urban air. Referring to the available literature, we discuss the likely sources of observed airborne bacteria, including soil, plants, animals, and humans. Our results on bacterial diversity are comparable to earlier studies, even though the sampling sites are different or geographically distant. However, the exact functional and ecological role of bioaerosols and, even more importantly, their impact on public health and the ecosystem requires further air monitoring and analysis.
Collapse
|
74
|
Bhardwaj J, Hong S, Jang J, Han CH, Lee J, Jang J. Recent advancements in the measurement of pathogenic airborne viruses. JOURNAL OF HAZARDOUS MATERIALS 2021; 420:126574. [PMID: 34252679 PMCID: PMC8256664 DOI: 10.1016/j.jhazmat.2021.126574] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2021] [Revised: 06/24/2021] [Accepted: 07/02/2021] [Indexed: 05/11/2023]
Abstract
Air-transmissible pathogenic viruses, such as influenza viruses and coronaviruses, are some of the most fatal strains and spread rapidly by air, necessitating quick and stable measurements from sample air volumes to prevent further spread of diseases and to take appropriate steps rapidly. Measurements of airborne viruses generally require their collection into liquids or onto solid surfaces, with subsequent hydrosolization and then analysis using the growth method, nucleic-acid-based techniques, or immunoassays. Measurements can also be performed in real time without sampling, where species-specific determination is generally disabled. In this review, we introduce some recent advancements in the measurement of pathogenic airborne viruses. Air sampling and measurement technologies for viral aerosols are reviewed, with special focus on the effects of air sampling on damage to the sampled viruses and their measurements. Measurement of pathogenic airborne viruses is an interdisciplinary research area that requires understanding of both aerosol technology and biotechnology to effectively address the issues. Hence, this review is expected to provide some useful guidelines regarding appropriate air sampling and virus detection methods for particular applications.
Collapse
Affiliation(s)
- Jyoti Bhardwaj
- Sensors and Aerosols Laboratory, Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | | | - Junbeom Jang
- Sensors and Aerosols Laboratory, Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Chang-Ho Han
- Sensors and Aerosols Laboratory, Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Jaegil Lee
- Sensors and Aerosols Laboratory, Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea
| | - Jaesung Jang
- Sensors and Aerosols Laboratory, Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan 44919, Republic of Korea; Department of Biomedical Engineering & Department of Urban and Environmental Engineering, UNIST, Ulsan 44919, Republic of Korea.
| |
Collapse
|
75
|
Hong S, Kim MW, Jang J. Physical collection and viability of airborne bacteria collected under electrostatic field with different sampling media and protocols towards rapid detection. Sci Rep 2021; 11:14598. [PMID: 34272448 PMCID: PMC8285527 DOI: 10.1038/s41598-021-94033-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2021] [Accepted: 06/28/2021] [Indexed: 11/21/2022] Open
Abstract
Electrostatic samplers have been increasingly studied for sampling of viral and bacterial aerosols, and bioaerosol samplers are required to provide concentrated liquid samples with high physical collection and biological recovery, which would be critical for rapid detection. Here, the effects of sampling media and protocols on the physical collection and biological recovery of two airborne bacteria (Pseudomonas fluorescens and Micrococcus luteus) under electrostatic field were investigated using a personal electrostatic particle concentrator (EPC). Deionized (DI) water with/without sodium dodecyl sulfate (SDS) and phosphate buffered saline were tested as sampling media. A polystyrene container was mounted onto the collection electrode of the EPC for stable storage and vortexing after capture. Many bacterial cells were found to be deposited on the bottom surface of the container submerged in the media via electrophoresis, and among the tested sampling protocols, wet sampling with a container and subsequent vortexing offered the most bacteria in the collection suspension. Experiments with several sampling media showed that 0.001-0.01% SDS-DI water demonstrated the highest recovery rate in the EPC. These findings would be valuable in the field of sampling and subsequent rapid detection of bioaerosols.
Collapse
Affiliation(s)
- Seongkyeol Hong
- Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, 44919, Republic of Korea
| | - Myeong-Woo Kim
- Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, 44919, Republic of Korea
| | - Jaesung Jang
- Department of Mechanical Engineering, Ulsan National Institute of Science and Technology (UNIST), Ulsan, 44919, Republic of Korea.
- Department of Biomedical Engineering, UNIST, Ulsan, 44919, Republic of Korea.
- Department of Urban and Environmental Engineering, UNIST, Ulsan, 44919, Republic of Korea.
| |
Collapse
|
76
|
Piri A, Kim HR, Park DH, Hwang J. Increased survivability of coronavirus and H1N1 influenza virus under electrostatic aerosol-to-hydrosol sampling. JOURNAL OF HAZARDOUS MATERIALS 2021; 413:125417. [PMID: 33930959 PMCID: PMC7879034 DOI: 10.1016/j.jhazmat.2021.125417] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 01/28/2021] [Accepted: 02/10/2021] [Indexed: 05/09/2023]
Abstract
Airborne virus susceptibility is an underlying cause of severe respiratory diseases, raising pandemic alerts worldwide. Following the first reports of the novel severe acute respiratory syndrome coronavirus-2 in 2019 and its rapid spread worldwide and the outbreak of a new highly variable strain of influenza A virus (H1N1) in 2009, developing quick, accurate monitoring and diagnostic approaches for emerging infections is considered critical. Efficient air sampling of coronaviruses and the H1N1 virus allows swift, real-time identification, triggering early adjuvant interventions. Electrostatic precipitation is an efficient method for sampling bio-aerosols as hydrosols; however, sampling conditions critically impact this method. Corona discharge ionizes surrounding air, generating reactive oxygen species (ROS), which may impair virus structural components, leading to RNA and/or protein damage and preventing virus detection. Herein, ascorbic acid (AA) dissolved in phosphate-buffered saline (PBS) was used as the sampling solution of an electrostatic sampler to counteract virus particle impairment, increasing virus survivability throughout sampling. The findings of this study indicate that the use of PBS+AA is effective in reducing the ROS damage of viral RNA by 95%, viral protein by 45% and virus yield by 60%.
Collapse
Affiliation(s)
- Amin Piri
- Department of Mechanical Engineering, Yonsei University, Seoul 120-749, Republic of Korea
| | - Hyeong Rae Kim
- Department of Mechanical Engineering, Yonsei University, Seoul 120-749, Republic of Korea
| | - Dae Hoon Park
- Department of Mechanical Engineering, Yonsei University, Seoul 120-749, Republic of Korea
| | - Jungho Hwang
- Department of Mechanical Engineering, Yonsei University, Seoul 120-749, Republic of Korea.
| |
Collapse
|
77
|
Li M, Wang L, Qi W, Liu Y, Lin J. Challenges and Perspectives for Biosensing of Bioaerosol Containing Pathogenic Microorganisms. MICROMACHINES 2021; 12:798. [PMID: 34357208 PMCID: PMC8307108 DOI: 10.3390/mi12070798] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Revised: 06/29/2021] [Accepted: 07/04/2021] [Indexed: 12/20/2022]
Abstract
As an important route for disease transmission, bioaerosols have received increasing attention. In the past decades, many efforts were made to facilitate the development of bioaerosol monitoring; however, there are still some important challenges in bioaerosol collection and detection. Thus, recent advances in bioaerosol collection (such as sedimentation, filtration, centrifugation, impaction, impingement, and microfluidics) and detection methods (such as culture, molecular biological assay, and immunological assay) were summarized in this review. Besides, the important challenges and perspectives for bioaerosol biosensing were also discussed.
Collapse
Affiliation(s)
| | | | | | | | - Jianhan Lin
- Key Laboratory of Agricultural Information Acquisition Technology, Ministry of Agriculture and Rural Affairs, China Agricultural University, Beijing 100083, China; (M.L.); (L.W.); (W.Q.); (Y.L.)
| |
Collapse
|
78
|
Ratnesar-Shumate S, Bohannon K, Williams G, Holland B, Krause M, Green B, Freeburger D, Dabisch P. Comparison of the performance of aerosol sampling devices for measuring infectious SARS-CoV-2 aerosols. AEROSOL SCIENCE AND TECHNOLOGY : THE JOURNAL OF THE AMERICAN ASSOCIATION FOR AEROSOL RESEARCH 2021; 55:975-986. [PMID: 38076006 PMCID: PMC10698689 DOI: 10.1080/02786826.2021.1910137] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Revised: 03/18/2021] [Accepted: 03/24/2021] [Indexed: 01/23/2024]
Abstract
To assess the risk of aerosol transmission of SARS-CoV-2, measurements of the airborne viral concentrations in proximity to infected individuals, the persistence of the virus in aerosols, and the dose of the virus needed to cause infection following inhalation are required. For studies aimed at quantifying these parameters, an aerosol sampling device needs to be employed. A number of recent studies have reported the detection of both genetic material and infectious SARS-CoV-2 virus in air samples collected in clinical settings. Previous studies have demonstrated that the efficiency of different samplers for collection and preservation of the infectivity of microorganisms can vary as a function of the specific microorganism. In the present study, the performance of eight common low-flow aerosol sampling devices were compared for their ability to collect and preserve the infectivity of airborne SARS-CoV-2 contained in small particle aerosols. The influence of sampling duration on recovery of infectious virus was also evaluated. Similar concentrations of infectious SARS-CoV-2 were measured in aerosols for the majority of the samplers tested, with the exception of the midget impingers, which measured significantly lower concentrations of SARS-CoV-2. Additionally, in three of the four impingers tested, additional clean airflow through the device following collection of infectious virus resulted in a decrease of the infectious concentration of virus over time, suggesting that virus was being inactivated and these devices may not be suitable for sampling for long durations. Further, RNA copies in the samples over time did not correspond with the losses of infectious SARS-CoV-2 observed in the impingers samples. These data can be utilized to inform interpretation of current studies on the SARS-CoV-2 viral loads in air samples, as well as inform sampling device selection in future studies.
Collapse
Affiliation(s)
| | - Kyle Bohannon
- Department of Homeland Security (DHS) Science and Technology Directorate (S&T), National Biodefense Analysis and Countermeasures Center (NBACC), Operated by Battelle National Biodefense Institute (BNBI) for the U.S., Frederick, Maryland, USA
| | - Gregory Williams
- Department of Homeland Security (DHS) Science and Technology Directorate (S&T), National Biodefense Analysis and Countermeasures Center (NBACC), Operated by Battelle National Biodefense Institute (BNBI) for the U.S., Frederick, Maryland, USA
| | - Brian Holland
- Department of Homeland Security (DHS) Science and Technology Directorate (S&T), National Biodefense Analysis and Countermeasures Center (NBACC), Operated by Battelle National Biodefense Institute (BNBI) for the U.S., Frederick, Maryland, USA
| | - Melissa Krause
- Department of Homeland Security (DHS) Science and Technology Directorate (S&T), National Biodefense Analysis and Countermeasures Center (NBACC), Operated by Battelle National Biodefense Institute (BNBI) for the U.S., Frederick, Maryland, USA
| | - Brian Green
- Department of Homeland Security (DHS) Science and Technology Directorate (S&T), National Biodefense Analysis and Countermeasures Center (NBACC), Operated by Battelle National Biodefense Institute (BNBI) for the U.S., Frederick, Maryland, USA
| | - Denise Freeburger
- Department of Homeland Security (DHS) Science and Technology Directorate (S&T), National Biodefense Analysis and Countermeasures Center (NBACC), Operated by Battelle National Biodefense Institute (BNBI) for the U.S., Frederick, Maryland, USA
| | - Paul Dabisch
- Department of Homeland Security (DHS) Science and Technology Directorate (S&T), National Biodefense Analysis and Countermeasures Center (NBACC), Operated by Battelle National Biodefense Institute (BNBI) for the U.S., Frederick, Maryland, USA
| |
Collapse
|
79
|
MYERS NIRMALAT, Calderón L, Pavilonis B, Wang Z, Xiong Y, Sorensen-Allacci M, Plotnik D, Senick J, Gong J, Krogmann U, Andrews CJ, Mainelis G. Presence and variability of culturable bioaerosols in three multi-family apartment buildings with different ventilation systems in the Northeastern US. INDOOR AIR 2021; 31:502-523. [PMID: 32931080 PMCID: PMC7904568 DOI: 10.1111/ina.12743] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2020] [Revised: 07/24/2020] [Accepted: 09/01/2020] [Indexed: 06/11/2023]
Abstract
Bioaerosol concentrations in residential buildings located in the Northeastern US have not been widely studied. Here, in 2011-2015, we studied the presence and seasonal variability of culturable fungi and bacteria in three multi-family apartment buildings and correlated the bioaerosol concentrations with building ventilation system types and environmental parameters. A total of 409 indoor and 86 outdoor samples were taken. Eighty-five percent of investigated apartments had indoor-outdoor (I/O) ratios of culturable fungi below 1, suggesting minimal indoor sources of fungi. In contrast, 56% of the apartments had I/O ratios for culturable bacteria above 1, indicating the prominence of indoor sources of bacteria. Culturable fungi I/O ratios in apartments serviced by central heating, ventilation, and air-conditioning (HVAC) system were lower than those in apartments with window AC. The type of ventilation system did not have a significant effect on the presence of indoor culturable bacteria. A significant positive association was determined between indoor dew point (DP) levels and indoor culturable fungi (P < .001) and bacteria (P < .001), regardless of ventilation type. Also, residents in apartments with central HVAC did not experience extreme DP values. We conclude that building ventilation systems, seasonality, and indoor sources are major factors affecting indoor bioaerosol levels in residential buildings.
Collapse
Affiliation(s)
- NIRMALA T. MYERS
- Rutgers, The State University of New Jersey, Department of Environmental Sciences, New Brunswick, NJ, USA
| | - Leonardo Calderón
- Rutgers, The State University of New Jersey, Department of Environmental Sciences, New Brunswick, NJ, USA
| | - Brian Pavilonis
- Rutgers, The State University of New Jersey, Department of Environmental Sciences, New Brunswick, NJ, USA
| | - Zuocheng Wang
- Rutgers, The State University of New Jersey, Department of Environmental Sciences, New Brunswick, NJ, USA
| | - Youyou Xiong
- Rutgers, The State University of New Jersey, Department of Environmental Sciences, New Brunswick, NJ, USA
| | - MaryAnn Sorensen-Allacci
- Rutgers, The State University of New Jersey, Edward J. Bloustein School of Planning and Public Policy, New Brunswick, NJ, USA
| | - Deborah Plotnik
- Rutgers, The State University of New Jersey, Edward J. Bloustein School of Planning and Public Policy, New Brunswick, NJ, USA
| | - Jennifer Senick
- Rutgers, The State University of New Jersey, Edward J. Bloustein School of Planning and Public Policy, New Brunswick, NJ, USA
| | - Jie Gong
- Rutgers, The State University of New Jersey, Department of Civil & Environmental Engineering, Piscataway, NJ, USA
| | - Uta Krogmann
- Rutgers, The State University of New Jersey, Department of Environmental Sciences, New Brunswick, NJ, USA
| | - Clinton J. Andrews
- Rutgers, The State University of New Jersey, Edward J. Bloustein School of Planning and Public Policy, New Brunswick, NJ, USA
| | - Gediminas Mainelis
- Rutgers, The State University of New Jersey, Department of Environmental Sciences, New Brunswick, NJ, USA
| |
Collapse
|
80
|
Han Y, Yang T, Han C, Li L, Liu J. Study of the generation and diffusion of bioaerosol under two aeration conditions. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2020; 267:115571. [PMID: 33254721 DOI: 10.1016/j.envpol.2020.115571] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 08/20/2020] [Accepted: 08/28/2020] [Indexed: 06/12/2023]
Abstract
Given that studies on actual sewage treatment plants are often affected by environmental conditions, it is challenging to clearly understand the associated bioaerosol generation and diffusion characteristics during the aeration process. Therefore, to enhance understanding in this regard, in this study, bioaerosol generator was used to simulate bioaerosol generation and diffusion under two aeration modes, i.e., bubble bottom aeration and brush surface aeration. The total concentration range of culturable bacteria in the bioaerosol produced by bubble bottom aeration and that produced by brush surface aeration were 300-3000 CFU/m3. Under bubble bottom aeration, the generated bioaerosol was symmetrically distributed around the source point, whereas under brush surface aeration, it was primarily distributed in the forward direction of the rotating brush surface. These bioaerosols from bubble bottom aeration predominantly consisted of particles with sizes below 3.3 μm, particularly those with sizes in the range 1.1-2.1 μm. On the contrary, the bioaerosols produced via brush surface aeration predominantly consisted of particles with sizes above 3.3 μm. The distribution characteristics of population structure in the two aeration modes were consistent with the distribution characteristics of concentration in the corresponding models. Additionally, the results showed that when the aeration process is unaffected by environmental conditions (particle matters, wind direct, wind speed, etc.), the bioaerosol components originate primarily from the parent sewage or sludge, and do not diffuse far from the source point. Therefore, source reduction (capping or sealing) can be recommended as the primary control strategy for bioaerosols in sewage treatment plants. The adoption of such measures will significantly limit the diffusion of bioaerosols, thereby reducing the potential risks associated with human exposure.
Collapse
Affiliation(s)
- Yunping Han
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China; University of Chinese Academy of Sciences, Beijing, 101408, PR China.
| | - Tang Yang
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China; University of Chinese Academy of Sciences, Beijing, 101408, PR China; School of Environmental and Municipal Engineering, Qingdao University of Technology, Qingdao 266033, PR China.
| | - Chao Han
- Tianjin Chengjian University, Tianjin, 300384, PR China.
| | - Lin Li
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China; University of Chinese Academy of Sciences, Beijing, 101408, PR China.
| | - Junxin Liu
- State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, PR China; University of Chinese Academy of Sciences, Beijing, 101408, PR China.
| |
Collapse
|
81
|
Bøifot KO, Gohli J, Skogan G, Dybwad M. Performance evaluation of high-volume electret filter air samplers in aerosol microbiome research. ENVIRONMENTAL MICROBIOME 2020; 15:14. [PMID: 33902714 PMCID: PMC8067322 DOI: 10.1186/s40793-020-00362-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Accepted: 07/13/2020] [Indexed: 06/12/2023]
Abstract
BACKGROUND Reliable identification and quantification of bioaerosols is fundamental in aerosol microbiome research, highlighting the importance of using sampling equipment with well-defined performance characteristics. Following advances in sequencing technology, shotgun metagenomic sequencing (SMS) of environmental samples is now possible. However, SMS of air samples is challenging due to low biomass, but with the use of high-volume air samplers sufficient DNA yields can be obtained. Here we investigate the sampling performance and comparability of two hand-portable, battery-operated, high-volume electret filter air samplers, SASS 3100 and ACD-200 Bobcat, previously used in SMS-based aerosol microbiome research. RESULTS SASS and Bobcat consistently delivered end-to-end sampling efficiencies > 80% during the aerosol chamber evaluation, demonstrating both as effective high-volume air samplers capable of retaining quantitative associations. Filter recovery efficiencies were investigated with manual and sampler-specific semi-automated extraction procedures. Bobcat semi-automated extraction showed reduced efficiency compared to manual extraction. Bobcat tended towards higher sampling efficiencies compared to SASS when combined with manual extraction. To evaluate real-world sampling performance, side-by-side SASS and Bobcat sampling was done in a semi-suburban outdoor environment and subway stations. SMS-based microbiome profiles revealed that highly abundant bacterial species had similar representation across samplers. While alpha diversity did not vary for the two samplers, beta diversity analyses showed significant within-pair variation in subway samples. Certain species were found to be captured only by one of the two samplers, particularly in subway samples. CONCLUSIONS SASS and Bobcat were both found capable of collecting sufficient aerosol biomass amounts for SMS, even at sampling times down to 30 min. Bobcat semi-automated filter extraction was shown to be less effective than manual filter extraction. For the most abundant species the samplers were comparable, but systematic sampler-specific differences were observed at species level. This suggests that studies conducted with these highly similar air samplers can be compared in a meaningful way, but it would not be recommended to combine samples from the two samplers in joint analyses. The outcome of this work contributes to improved selection of sampling equipment for use in SMS-based aerosol microbiome research and highlights the importance of acknowledging bias introduced by sampling equipment and sample recovery procedures.
Collapse
Affiliation(s)
- Kari Oline Bøifot
- Norwegian Defence Research Establishment FFI, P O Box 25, NO-2027, Kjeller, Norway
- Department of Analytics, Environmental & Forensic Sciences, King's College London, 150 Stamford Street, London, SE1 9NH, UK
| | - Jostein Gohli
- Norwegian Defence Research Establishment FFI, P O Box 25, NO-2027, Kjeller, Norway
| | - Gunnar Skogan
- Norwegian Defence Research Establishment FFI, P O Box 25, NO-2027, Kjeller, Norway
| | - Marius Dybwad
- Norwegian Defence Research Establishment FFI, P O Box 25, NO-2027, Kjeller, Norway.
- Department of Analytics, Environmental & Forensic Sciences, King's College London, 150 Stamford Street, London, SE1 9NH, UK.
| |
Collapse
|
82
|
Kabir E, Azzouz A, Raza N, Bhardwaj SK, Kim KH, Tabatabaei M, Kukkar D. Recent Advances in Monitoring, Sampling, and Sensing Techniques for Bioaerosols in the Atmosphere. ACS Sens 2020; 5:1254-1267. [PMID: 32227840 DOI: 10.1021/acssensors.9b02585] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Bioaerosols in the form of microscopic airborne particles pose pervasive risks to humans and livestock. As either fully active components (e.g., viruses, bacteria, and fungi) or as whole or part of inactive fragments, they are among the least investigated pollutants in nature. Their identification and quantification are essential to addressing related dangers and to establishing proper exposure thresholds. However, difficulties in the development (and selection) of detection techniques and an associated lack of standardized procedures make the sensing of bioaerosols challenging. Through a comprehensive literature search, this review examines the mechanisms of conventional and advanced bioaerosol detection methods. It also provides a roadmap for future research and development in the selection of suitable methodologies for bioaerosol detection. The development of sample collection and sensing technology make it possible for continuous and automated operation. However, intensive efforts should be put to overcome the limitations of current technology as most of the currently available options tend to suffer from lengthy sample acquisition times and/or nonspecificity of probe material.
Collapse
Affiliation(s)
- Ehsanul Kabir
- Department of Farm Power and Machinery, Bangladesh Agricultural University, Mymensingh 2202, Bangladesh
| | - Abdelmonaim Azzouz
- Department of Chemistry, Faculty of Science, University of Abdelmalek Essaadi, B.P. 2121, M’Hannech II, 93002 Tétouan, Morocco
| | - Nadeem Raza
- Government Emerson College, Bahauddin Zakariya University, Multan 60800, Pakistan
| | - Sanjeev Kumar Bhardwaj
- Center of Innovative and Applied Bioprocessing, (CIAB) [DBT, Govt. of India], Knowledge
City, Sector 81, Mohali, Punjab 140306, India
| | - Ki-Hyun Kim
- Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul 04763, Korea
| | - Meisam Tabatabaei
- Microbial Biotechnology Department, Agricultural Biotechnology Institute of Iran, Agricultural Research, Education, and Extension Organization (AREEO), 31535-1897 Karaj, Iran
| | - Deepak Kukkar
- Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul 04763, Korea
| |
Collapse
|
83
|
Cox J, Mbareche H, Lindsley WG, Duchaine C. Field sampling of indoor bioaerosols. AEROSOL SCIENCE AND TECHNOLOGY : THE JOURNAL OF THE AMERICAN ASSOCIATION FOR AEROSOL RESEARCH 2019; 54:572-584. [PMID: 31777412 PMCID: PMC6880939 DOI: 10.1080/02786826.2019.1688759] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Revised: 10/15/2019] [Accepted: 10/22/2019] [Indexed: 05/04/2023]
Abstract
Because bioaerosols are related to adverse health effects in exposed humans and indoor environments represent a unique framework of exposure, concerns about indoor bioaerosols have risen over recent years. One of the major issues in indoor bioaerosol research is the lack of standardization in the methodology, from air sampling strategies and sample treatment to the analytical methods applied. The main characteristics to consider in the choice of indoor sampling methods for bioaerosols are the sampler performance, the representativeness of the sampling, and the concordance with the analytical methods to be used. The selection of bioaerosol collection methods is directly dependent on the analytical methods, which are chosen to answer specific questions raised while designing a study for exposure assessment. In this review, the authors present current practices in the analytical methods and the sampling strategies, with specificity for each type of microbe (fungi, bacteria, archaea and viruses). In addition, common problems and errors to be avoided are discussed. Based on this work, recommendations are made for future efforts towards the development of viable bioaerosol samplers, standards for bioaerosol exposure limits, and making association studies to optimize the use of the big data provided by high-throughput sequencing methods.
Collapse
Affiliation(s)
- Jennie Cox
- Department of Environmental Health, University of Cincinnati, Cincinnati, Ohio, USA
| | - Hamza Mbareche
- Department of Biochemistry, Microbiology, and Bioinformatics, Université Laval, Québec, Canada
| | - William G. Lindsley
- National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, West Virginia, USA
| | - Caroline Duchaine
- Department of Biochemistry, Microbiology, and Bioinformatics, Université Laval, Québec, Canada
| |
Collapse
|