151
|
Abstract
Diagnostic assays are an important part of health care, both in the clinic and in research laboratories. In addition to improving treatments and clinical outcomes, rapid and reliable diagnostics help track disease epidemiology, curb infectious outbreaks, and further the understanding of chronic illness. Disease markers such as antigens, RNA, and DNA are present at low concentrations in biological samples, such that the majority of diagnostic assays rely on an amplification reaction before detection is possible. Ideally, these amplification reactions would be sensitive, specific, inexpensive, rapid, integrated, and automated. Microfluidic technology currently in development offers many advantages over conventional benchtop reactions that help achieve these goals. The small reaction volumes and energy consumption make reactions cheaper and more efficient in a microfluidic reactor. Additionally, the channel architecture could be designed to perform multiple tests or experimental steps on one integrated, automated platform. This review explores the current research on microfluidic reactors designed to aid diagnostic applications, covering a broad spectrum of amplification techniques and designs.
Collapse
Affiliation(s)
- Stephanie E McCalla
- Center for Biomedical Engineering, School of Engineering and Medical Sciences, Brown University, Providence, RI 02912, USA
| | | |
Collapse
|
152
|
Choi JY, Kim YT, Ahn J, Kim KS, Gweon DG, Seo TS. Integrated allele-specific polymerase chain reaction-capillary electrophoresis microdevice for single nucleotide polymorphism genotyping. Biosens Bioelectron 2012; 35:327-334. [PMID: 22464916 DOI: 10.1016/j.bios.2012.03.009] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2011] [Revised: 02/09/2012] [Accepted: 03/08/2012] [Indexed: 11/30/2022]
Abstract
An integrated allele-specific (AS) polymerase chain reaction (PCR) and capillary electrophoresis (CE) microdevice has been developed for multiplex single nucleotide polymorphism (SNP) genotyping on a portable instrumentation, which was applied for on-site identification of HANWOO (Korean indigenous beef cattle). Twelve sets of primers were designed for targeting beef cattle's eleven SNP loci for HANWOO verification and one primer set for a positive PCR control, and the success rate for identification of HANWOO was demonstrated statistically. The AS PCR and CE separation for multiplex SNP typing was carried out on a glass-based microchip consisting of four layers: a microchannel plate for microfluidic control, a Pt-electrode plate for a resistance temperature detector (RTD), a poly(dimethylsiloxane) (PDMS) membrane and a manifold glass for microvalve function. The operation of the sample loading, AS PCR, microvalve, and CE on a chip was automated with a portable genetic analyzer, and the laser-induced fluorescence detection was performed on a miniaturized fluorescence detector. The blind samples were correctly identified as a HANWOO by showing one or two amplicon peaks in the electropherogram, while the imported beef cattle revealed more than five peaks. Our genetic analysis platform provides rapid, accurate, and on-site multiplex SNP typing.
Collapse
Affiliation(s)
- Jong Young Choi
- Department of Chemical and Biomolecular Engineering (BK21 Program) and KAIST Institute for the BioCentury, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 305-701, Republic of Korea
| | - Yong Tae Kim
- Department of Chemical and Biomolecular Engineering (BK21 Program) and KAIST Institute for the BioCentury, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 305-701, Republic of Korea
| | - Jinwoo Ahn
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Dahak-ro, Yuseong-gu, Daejeon 305-701, Republic of Korea
| | - Kwan Suk Kim
- College of Agriculture, Life and Environment Sciences, Chungbuk National University, 52 Naesudong-ro, Heungdeok-gu, Cheongju, Chungbuk 361-763, Republic of Korea
| | - Dae-Gab Gweon
- Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Dahak-ro, Yuseong-gu, Daejeon 305-701, Republic of Korea
| | - Tae Seok Seo
- Department of Chemical and Biomolecular Engineering (BK21 Program) and KAIST Institute for the BioCentury, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 305-701, Republic of Korea.
| |
Collapse
|
153
|
Abstract
A portable, fully automated analyzer that provides actuation and flow control to a disposable, self-contained, microfluidic cassette ("chip") for point-of-care, molecular testing is described. The analyzer provides mechanical actuation to compress pouches that pump liquids in the cassette, to open and close diaphragm valves for flow control, and to induce vibrations that enhance stirring. The analyzer also provides thermal actuation for the temperature cycling needed for polymerase chain reaction (PCR) amplification of nucleic acids and for various drying processes. To improve the temperature uniformity of the PCR chamber, the system utilizes a double-sided heating/cooling scheme with a custom feedforward, variable, structural proportional-integral-derivative (FVSPID) controller. The analyzer includes a programmable central processing unit that directs the sequence and timing of the various operations and that is interfaced with a computer. The disposable cassette receives a sample, and it carries out cell lysis, nucleic acid isolation, concentration, and purification, thermal cycling, and either real time or lateral flow (LF) based detection. The system's operation was demonstrated by processing saliva samples spiked with B. cereus cells. The amplicons were detected with a lateral flow assay using upconverting phosphor reporter particles. This system is particularly suited for use in regions lacking centralized laboratory facilities and skilled personnel.
Collapse
|
154
|
Angione SL, Chauhan A, Tripathi A. Real-Time Droplet DNA Amplification with a New Tablet Platform. Anal Chem 2012; 84:2654-61. [DOI: 10.1021/ac202532a] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Affiliation(s)
- Stephanie L. Angione
- Center for Biomedical Engineering,
School of Engineering and Division of Biology and Medicine, Brown University, Providence, Rhode Island, United
States
| | - Anuj Chauhan
- Department of Chemical
Engineering, University of Florida, Gainesville,
Florida, United
States
| | - Anubhav Tripathi
- Center for Biomedical Engineering,
School of Engineering and Division of Biology and Medicine, Brown University, Providence, Rhode Island, United
States
| |
Collapse
|
155
|
Cooney CG, Sipes D, Thakore N, Holmberg R, Belgrader P. A plastic, disposable microfluidic flow cell for coupled on-chip PCR and microarray detection of infectious agents. Biomed Microdevices 2012; 14:45-53. [PMID: 21909803 PMCID: PMC5882199 DOI: 10.1007/s10544-011-9584-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Clinical laboratories are recognizing the importance of implementing sensitive and specific molecular diagnostic tests. However, widespread adoption of these tests requires simplified workflows without requiring expensive supporting instrumentation. To enable microarray-based analysis to meet these requirements, we describe a valveless flow cell for disposable use that supports PCR coupled with microarray hybridization in the same chamber. The flow cell assembly consists simply of double-faced tape, a plastic microarray substrate, an absorbent, and a commercially-available hydrophilic thin film. The simple construction lends itself to low-cost and ease of manufacturing, yet several features reduce the complexity of the standard microarray workflow. First, there is no requirement for custom instrumentation. Second, the hydrophilic thin film allows uniform filling of a microfluidic chamber. Third, a geometric capillary stop design confines liquid to the microarray chamber during PCR, and thus eliminates the need for a valve or hydrophobic surface treatment. And fourth, imbibition drives the uniform removal of liquid reagents from the array chamber. Three hundred genomic copies of methicillin-resistant Staphylococcus aureus (MRSA) are detected in a flow cell with gel drop microarrays printed on an unmodified plastic substrate. This sensitivity is shown to be comparable to conventional methods (i.e., PCR in a tube, with separate hybridization in a microarray chamber, where amplicon is exposed to the workspace before and after hybridization). However, the flow cell combines these multiple steps into a simple, compact workflow without the need for complex valves or custom instrumentation and is less susceptible to contamination of the workspace than conventional methods because the amplicon is confined to the device.
Collapse
|
156
|
Estes MD, Yang J, Duane B, Smith S, Brooks C, Nordquist A, Zenhausern F. Optimization of multiplexed PCR on an integrated microfluidic forensic platform for rapid DNA analysis. Analyst 2012; 137:5510-9. [DOI: 10.1039/c2an35768b] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
157
|
Lie P, Liu J, Fang Z, Dun B, Zeng L. A lateral flow biosensor for detection of nucleic acids with high sensitivity and selectivity. Chem Commun (Camb) 2012; 48:236-8. [DOI: 10.1039/c1cc15878c] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
158
|
Lam B, Fang Z, Sargent EH, Kelley SO. Polymerase chain reaction-free, sample-to-answer bacterial detection in 30 minutes with integrated cell lysis. Anal Chem 2011; 84:21-5. [PMID: 22142422 DOI: 10.1021/ac202599b] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
An important goal for improved diagnosis and management of infectious disease is the development of rapid and accurate technologies for the decentralized detection of bacterial pathogens. Most current clinical methods that identify bacterial strains require time-consuming culture of the sample or procedures involving the polymerase chain reaction. Neither of these approaches has enabled testing at the point-of-need because of the requirement for skilled technicians and laboratory facilities. Here, we demonstrate the performance of an effective, integrated platform for the rapid detection of bacteria that combines a universal bacterial lysis approach and a sensitive nanostructured electrochemical biosensor. The lysis is rapid, is effective at releasing intercellular RNA from bacterial samples, and can be performed in a simple, cost-effective device integrated with an analysis chip. The platform was directly challenged with these unpurified lysates in buffer and urine. We successfully detected the presence of bacteria with high sensitivity and specificity and achieved a sample-to-answer turnaround time of 30 min. We have met the clinically relevant detection limit of 1 cfu/μL, indicating that uncultured samples can be analyzed. This advance will greatly reduce time to successful detection from days to minutes.
Collapse
Affiliation(s)
- Brian Lam
- Department of Chemistry, Faculty of Arts and Sciences, University of Toronto, Toronto, Ontario, Canada
| | | | | | | |
Collapse
|
159
|
Göransson Nyberg A, Stricklin D, Sellström Å. Mass casualties and health care following the release of toxic chemicals or radioactive material--contribution of modern biotechnology. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2011; 8:4521-49. [PMID: 22408587 PMCID: PMC3290976 DOI: 10.3390/ijerph8124521] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2011] [Revised: 11/25/2011] [Accepted: 11/29/2011] [Indexed: 11/16/2022]
Abstract
Catastrophic chemical or radiological events can cause thousands of casualties. Such disasters require triage procedures to identify the development of health consequences requiring medical intervention. Our objective is to analyze recent advancements in biotechnology for triage in mass emergency situations. In addition to identifying persons "at risk" of developing health problems, these technologies can aid in securing the unaffected or "worried well". We also highlight the need for public/private partnerships to engage in some of the underpinning sciences, such as patho-physiological mechanisms of chemical and radiological hazards, and for the necessary investment in the development of rapid assessment tools through identification of biochemical, molecular, and genetic biomarkers to predict health effects. For chemical agents, biomarkers of neurotoxicity, lung damage, and clinical and epidemiological databases are needed to assess acute and chronic effects of exposures. For radiological exposures, development of rapid, sensitive biomarkers using advanced biotechnologies are needed to sort exposed persons at risk of life-threatening effects from persons with long-term risk or no risk. The final implementation of rapid and portable diagnostics tools suitable for emergency care providers to guide triage and medical countermeasures use will need public support, since commercial incentives are lacking.
Collapse
Affiliation(s)
- Ann Göransson Nyberg
- Swedish Defence Research Agency, FOI CBRN—Defence and Security, 20 Cementvägen, SE 901 82 Umea, Sweden
| | - Daniela Stricklin
- Applied Research Associates, Inc., 1235 South Clark Street Ste, Arlington, VA 22203, USA;
| | - Åke Sellström
- European CBRNE Center, KBC Building, 6 Linnaeus väg, SE 901 87 Umea, Sweden;
| |
Collapse
|
160
|
Liu Q, Liu A, Gao F, Weng S, Zhong G, Liu J, Lin X, Lin JH, Chen X. Coupling technique of random amplified polymorphic DNA and nanoelectrochemical sensor for mapping pancreatic cancer genetic fingerprint. Int J Nanomedicine 2011; 6:2933-9. [PMID: 22162652 PMCID: PMC3230562 DOI: 10.2147/ijn.s25842] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
OBJECTIVE To review the feasibility of coupling the techniques of random amplified polymorphic DNA (RAPD) with carbon nanotube-based modified electrode for guanine/deoxyguanine triphosphate (dGTP) electrochemical sensing for mapping of the pancreatic cancer genetic fingerprint and screening of genetic alterations. METHODS We developed a new method to study the electrochemical behavior of dGTP utilizing carbon multiwalled nanotube (MWNT)-modified glassy carbon electrodes (GCEs). RAPD was applied for amplification of DNA samples from healthy controls and patients with pancreatic cancer under the same conditions to determine the different surplus quantity of dGTP in the polymerase chain reaction (PCR), thereby determining the difference/quantity of PCR products or template strands. Using this method we generated a genetic fingerprint map of pancreatic cancer through the combination of electrochemical sensors and gel electrophoresis to screen for genetic alterations. Cloning and sequencing were then performed to verify these gene alterations. RESULTS dGTP showed favorable electrochemical behavior on the MWNTs/GCE. The results indicated that the electrical signal and dGTP had a satisfactory linear relationship with the dGTP concentration within the conventional PCR concentration range. The MWNTs/GCE could distinguish between different products of RAPD. This experiment successfully identified a new pancreatic cancer-associated mutant gene fragment, consisting of a cyclin-dependent kinase 4 gene 3' terminal mutation. CONCLUSION The coupling of RAPD and nanoelectrochemical sensors was successfully applied to the screening of genetic alterations in pancreatic cancer and for mapping of DNA fingerprints.
Collapse
Affiliation(s)
- Qicai Liu
- Department of Laboratory Medicine, Fujian Medical University, Fuzhou
| | | | | | | | | | | | | | | | | |
Collapse
|
161
|
Hwang KY, Kwon SH, Jung SO, Lim HK, Jung WJ, Park CS, Kim JH, Suh KY, Huh N. Miniaturized bead-beating device to automate full DNA sample preparation processes for gram-positive bacteria. LAB ON A CHIP 2011; 11:3649-3655. [PMID: 21918771 DOI: 10.1039/c1lc20692c] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We have developed a miniaturized bead-beating device to automate nucleic acids extraction from Gram-positive bacteria for molecular diagnostics. The microfluidic device was fabricated by sandwiching a monolithic flexible polydimethylsiloxane (PDMS) membrane between two glass wafers (i.e., glass-PDMS-glass), which acted as an actuator for bead collision via its pneumatic vibration without additional lysis equipment. The Gram-positive bacteria, S. aureus and methicillin-resistant S. aureus, were captured on surface-modified glass beads from 1 mL of initial sample solution and in situ lyzed by bead-beating operation. Then, 10 μL or 20 μL of bacterial DNA solution was eluted and amplified successfully by real-time PCR. It was found that liquid volume fraction played a crucial role in determining the cell lysis efficiency in a confined chamber by facilitating membrane deflection and bead motion. The miniaturized bead-beating operation disrupted most of S. aureus within 3 min, which turned out to be as efficient as the conventional benchtop vortexing machine or the enzyme-based lysis technique. The effective cell concentration was significantly enhanced with the reduction of initial sample volume by 50 or 100 times. Combination of such analyte enrichment and in situ bead-beating lysis provided an excellent PCR detection sensitivity amounting to ca. 46 CFU even for the Gram-positive bacteria. The proposed bead-beating microdevice is potentially useful as a nucleic acid extraction method toward a PCR-based sample-to-answer system.
Collapse
Affiliation(s)
- Kyu-Youn Hwang
- Bio Lab, Samsung Advanced Institute of Technology (SAIT), Samsung Electronics Co., Ltd., Republic of Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
162
|
Sabatte G, Feitsma H, Evers TH, Prins MW. Protein biomarker enrichment by biomarker antibody complex elution for immunoassay biosensing. Biosens Bioelectron 2011; 29:18-22. [DOI: 10.1016/j.bios.2011.06.046] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2011] [Revised: 06/27/2011] [Accepted: 06/28/2011] [Indexed: 12/28/2022]
|
163
|
Jung JH, Kim GY, Seo TS. An integrated passive micromixer-magnetic separation-capillary electrophoresis microdevice for rapid and multiplex pathogen detection at the single-cell level. LAB ON A CHIP 2011; 11:3465-70. [PMID: 21870015 DOI: 10.1039/c1lc20350a] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Here we report an integrated microdevice consisting of an efficient passive mixer, a magnetic separation chamber, and a capillary electrophoretic microchannel in which DNA barcode assay, target pathogen separation, and barcode DNA capillary electrophoretic analysis were performed sequentially within 30 min for multiplex pathogen detection at the single-cell level. The intestine-shaped serpentine 3D micromixer provides a high mixing rate to generate magnetic particle-pathogenic bacteria-DNA barcode labelled AuNP complexes quantitatively. After magnetic separation and purification of those complexes, the barcode DNA strands were released and analyzed by the microfluidic capillary electrophoresis within 5 min. The size of the barcode DNA strand was controlled depending on the target bacteria (Staphylococcus aureus, Escherichia coli O157:H7, and Salmonella typhimurium), and the different elution time of the barcode DNA peak in the electropherogram allows us to recognize the target pathogen with ease in the monoplex as well as in the multiplex analysis. In addition, the quantity of the DNA barcode strand (∼10(4)) per AuNP is enough to be observed in the laser-induced confocal fluorescence detector, thereby making single-cell analysis possible. This novel integrated microdevice enables us to perform rapid, sensitive, and multiplex pathogen detection with sample-in-answer-out capability to be applied for biosafety testing, environmental screening, and clinical trials.
Collapse
Affiliation(s)
- Jae Hwan Jung
- Department of Chemical and Biomolecular Engineering (BK21 program), Korea Advanced Institute of Science and Technology (KAIST), Yuseong-gu, Daejeon, South Korea
| | | | | |
Collapse
|
164
|
Daghighi Y, Li D. Micro-valve using induced-charge electrokinetic motion of Janus particle. LAB ON A CHIP 2011; 11:2929-2940. [PMID: 21769339 DOI: 10.1039/c1lc20229d] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
A new micro-valve using the electrokinetic motion of a Janus particle is introduced in this paper. A Janus particle with a conducting hemisphere and a non-conducting hemisphere is placed in a junction of several microchannels. Under an applied electric field, the induced-charge electrokinetic flow around the conducting side of the Janus particle forms vortices. The vortices push the particle moving forwards to block the entrance of a microchannel. By switching the direction of the applied electric field, the motion of the Janus particle can be changed to block different microchannels. This paper develops a theoretical model and conducts numerical simulations of the three-dimensional transient motion of the Janus particle. The results show that this Janus particle-based micro-valve is feasible for switching and controlling the flow rate in a microfluidic chip. This method is simple in comparison with other types of micro-valve methods. It is easy for fabrication, for operation control, and has a fast response time. To better understand the micro-valve functions, comparisons with a non-conducting particle and a fully conducting particle were made. Results proved that only a Janus particle can fulfill the requirements of such a micro-valve.
Collapse
Affiliation(s)
- Yasaman Daghighi
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, Waterloo, Ontario, Canada N2L 3G1
| | | |
Collapse
|
165
|
Xu G, Lee DYS, Xie H, Chiew D, Hsieh TM, Ali EM, Lun Looi X, Li MH, Ying JY. A self-contained polymeric cartridge for automated biological sample preparation. BIOMICROFLUIDICS 2011; 5:34107-341079. [PMID: 22662036 PMCID: PMC3364824 DOI: 10.1063/1.3614441] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/12/2011] [Accepted: 06/22/2011] [Indexed: 06/01/2023]
Abstract
Sample preparation is one of the most crucial processes for nucleic acids based disease diagnosis. Several steps are required for nucleic acids extraction, impurity washes, and DNA/RNA elution. Careful sample preparation is vital to the obtaining of reliable diagnosis, especially with low copies of pathogens and cells. This paper describes a low-cost, disposable lab cartridge for automatic sample preparation, which is capable of handling flexible sample volumes of 10 μl to 1 ml. This plastic cartridge contains all the necessary reagents for pathogen and cell lysis, DNA/RNA extraction, impurity washes, DNA/RNA elution and waste processing in a completely sealed cartridge. The entire sample preparation processes are automatically conducted within the cartridge on a desktop unit using a pneumatic fluid manipulation approach. Reagents transportation is achieved with a combination of push and pull forces (with compressed air and vacuum, respectively), which are connected to the pneumatic inlets at the bottom of the cartridge. These pneumatic forces are regulated by pinch valve manifold and two pneumatic syringe pumps within the desktop unit. The performance of this pneumatic reagent delivery method was examined. We have demonstrated the capability of the on-cartridge RNA extraction and cancer-specific gene amplification from 10 copies of MCF-7 breast cancer cells. The on-cartridge DNA recovery efficiency was 54-63%, which was comparable to or better than the conventional manual approach using silica spin column. The lab cartridge would be suitable for integration with lab-chip real-time polymerase chain reaction devices in providing a portable system for decentralized disease diagnosis.
Collapse
Affiliation(s)
- Guolin Xu
- Institute of Bioengineering and Nanotechnology, 31 Biopolis Way, The Nanos, Singapore 138669
| | | | | | | | | | | | | | | | | |
Collapse
|
166
|
Wang R, Lin J, Lassiter K, Srinivasan B, Lin L, Lu H, Tung S, Hargis B, Bottje W, Berghman L, Li Y. Evaluation study of a portable impedance biosensor for detection of avian influenza virus. J Virol Methods 2011; 178:52-8. [PMID: 21872621 DOI: 10.1016/j.jviromet.2011.08.011] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2011] [Revised: 07/29/2011] [Accepted: 08/10/2011] [Indexed: 11/15/2022]
Abstract
Current methods for detection of avian influenza virus (AIV) based on virus culture and RT-PCR are well established, but they are either time consuming or require specialized laboratory facilities and highly trained technicians. A simple, rapid, robust, and reliable test, suitable for use in the field or at the patient's bedside, is urgently needed. In this study, the performance of a newly developed portable impedance biosensor was evaluated by comparison with real-time reverse transcriptase PCR (rRT-PCR) and virus culture for detection of AIV in tracheal and cloacal swab samples collected from experimentally H5N2 AIV infected chickens. The impedance biosensor system was based on a combination of magnetic nanobeads, which were coated with AIV subtype-specific antibody for capture (separation and concentration) of a target virus, and a microfluidic chip with an interdigitated array microelectrode for transfer and detection of target virus, and impedance measurement of the bio-nanobeads and AI virus complexes in a buffer solution. A comparison of results obtained from 59 swab samples using virus culture, impedance biosensor and rRT-PCR methods showed that the impedance biosensor technique was comparable in sensitivity and specificity to rRT-PCR. Detection time for the impedance biosensor is less than 1h.
Collapse
Affiliation(s)
- Ronghui Wang
- Department of Biological and Agricultural Engineering, University of Arkansas, Fayetteville, AR 72701, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
167
|
Shahini M, Yeow JTW. Carbon nanotubes for voltage reduction and throughput enhancement of electrical cell lysis on a lab-on-a-chip. NANOTECHNOLOGY 2011; 22:325705. [PMID: 21775777 DOI: 10.1088/0957-4484/22/32/325705] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We report on the enhancement of electrical cell lysis using carbon nanotubes (CNTs). Electrical cell lysis systems are widely utilized in microchips as they are well suited to integration into lab-on-a-chip devices. However, cell lysis based on electrical mechanisms has high voltage requirements. Here, we demonstrate that by incorporating CNTs into microfluidic electrolysis systems, the required voltage for lysis is reduced by half and the lysis throughput at low voltages is improved by ten times, compared to non-CNT microchips. In our experiment, E. coli cells are lysed while passing through an electric field in a microchannel. Based on the lightning rod effect, the electric field strengthened at the tip of the CNTs enhances cell lysis at lower voltage and higher throughput. This approach enables easy integration of cell lysis with other on-chip high-throughput sample-preparation processes.
Collapse
Affiliation(s)
- Mehdi Shahini
- University of Waterloo, 200 University Avenue West, Waterloo, ON, Canada
| | | |
Collapse
|
168
|
Wu J, Gu M. Microfluidic sensing: state of the art fabrication and detection techniques. JOURNAL OF BIOMEDICAL OPTICS 2011; 16:080901. [PMID: 21895307 DOI: 10.1117/1.3607430] [Citation(s) in RCA: 92] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Here we introduce the existing fabrication techniques, detection methods, and related techniques for microfluidic sensing, with an emphasis on the detection techniques. A general survey and comparison of the fabrication techniques were given, including prototyping (hot embossing, inject molding, and soft lithography) and direct fabrication (laser micromachining, photolithography, lithography, and x-ray lithography) techniques. This is followed by an in-depth look at detection techniques: optical, electrochemical, mass spectrometry, as well as nuclear magnetic resonance spectroscopy-based sensing approaches and related techniques. In the end, we highlight several of the most important issues for future work on microfluidic sensing. This article aims at providing a tutorial review with both introductory materials and inspiring information on microfluidic fabrication and sensing for nonspecialists.
Collapse
Affiliation(s)
- Jing Wu
- Zhejiang University, State Key Lab of Modern Optical Instrumentation, Department of Optical Engineering, Institute of Advanced Nanophotonics, Zheda Road 38, Xihu District, Hangzhou, Zhejiang 310027, China.
| | | |
Collapse
|
169
|
Park S, Zhang Y, Lin S, Wang TH, Yang S. Advances in microfluidic PCR for point-of-care infectious disease diagnostics. Biotechnol Adv 2011; 29:830-9. [PMID: 21741465 DOI: 10.1016/j.biotechadv.2011.06.017] [Citation(s) in RCA: 218] [Impact Index Per Article: 15.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2011] [Revised: 05/14/2011] [Accepted: 06/22/2011] [Indexed: 12/20/2022]
Abstract
Global burdens from existing or emerging infectious diseases emphasize the need for point-of-care (POC) diagnostics to enhance timely recognition and intervention. Molecular approaches based on PCR methods have made significant inroads by improving detection time and accuracy but are still largely hampered by resource-intensive processing in centralized laboratories, thereby precluding their routine bedside- or field-use. Microfluidic technologies have enabled miniaturization of PCR processes onto a chip device with potential benefits including speed, cost, portability, throughput, and automation. In this review, we provide an overview of recent advances in microfluidic PCR technologies and discuss practical issues and perspectives related to implementing them into infectious disease diagnostics.
Collapse
Affiliation(s)
- Seungkyung Park
- Department of Emergency Medicine, Johns Hopkins University, Baltimore, MD 21205, USA
| | | | | | | | | |
Collapse
|
170
|
Chia BT, Yang XY, Cheng MY, Lin CW, Yang YJ. An electromagnetically-driven microfluidic platform with indirect-heating thermo-pneumatic valves. BIOCHIP JOURNAL 2011. [DOI: 10.1007/s13206-011-5201-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
171
|
Ferguson BS, Buchsbaum SF, Wu TT, Hsieh K, Xiao Y, Sun R, Soh HT. Genetic analysis of H1N1 influenza virus from throat swab samples in a microfluidic system for point-of-care diagnostics. J Am Chem Soc 2011; 133:9129-35. [PMID: 21561070 PMCID: PMC3110979 DOI: 10.1021/ja203981w] [Citation(s) in RCA: 164] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The ability to obtain sequence-specific genetic information about rare target organisms directly from complex biological samples at the point-of-care would transform many areas of biotechnology. Microfluidics technology offers compelling tools for integrating multiple biochemical processes in a single device, but despite significant progress, only limited examples have shown specific, genetic analysis of clinical samples within the context of a fully integrated, portable platform. Herein we present the Magnetic Integrated Microfluidic Electrochemical Detector (MIMED) that integrates sample preparation and electrochemical sensors in a monolithic disposable device to detect RNA-based virus directly from throat swab samples. By combining immunomagnetic target capture, concentration, and purification, reverse-transcriptase polymerase chain reaction (RT-PCR) and single-stranded DNA (ssDNA) generation in the sample preparation chamber, as well as sequence-specific electrochemical DNA detection in the electrochemical cell, we demonstrate the detection of influenza H1N1 in throat swab samples at loads as low as 10 TCID(50), 4 orders of magnitude below the clinical titer for this virus. Given the availability of affinity reagents for a broad range of pathogens, our system offers a general approach for multitarget diagnostics at the point-of-care.
Collapse
|
172
|
Berry SM, Alarid ET, Beebe DJ. One-step purification of nucleic acid for gene expression analysis via Immiscible Filtration Assisted by Surface Tension (IFAST). LAB ON A CHIP 2011; 11:1747-53. [PMID: 21423999 PMCID: PMC3244820 DOI: 10.1039/c1lc00004g] [Citation(s) in RCA: 120] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The extraction and purification of nucleic acids from complex samples (e.g. blood, biopsied tissue, cultured cells, food) is an essential prerequisite for many applications in biology including genotyping, transcriptional analysis, systems biology, epigenetic analysis, and virus/bacterial detection. In this report, we describe a new process of nucleic acid extraction that utilizes "pinned" aqueous/organic liquid interfaces in microchannels to streamline the extraction mechanism, replacing all washing steps with a single traverse of an immiscible fluid barrier, termed Immiscible Filtration Assisted by Surface Tension (IFAST). Nucleic acids in biological samples are bound to paramagnetic particles and then drawn across the IFAST device (or array of IFAST devices) using a magnet. While the strength of the IFAST barrier is suitable for separation of nucleic acids from lysate in its current embodiment, its permeability can be selectively adapted by adjusting the surface tensions/energies associated with the cell lysate, the immiscible phase, and the device surface, enabling future expansion to other non-nucleic acid applications. Importantly, processing time is reduced from 15-45 minutes to less than 5 minutes while maintaining purity, yield, and scalability equal to or better than prevailing methods. Operation is extremely simple and no additional lab infrastructure is required. The IFAST technology thus significantly enhances researchers' abilities to isolate and analyze nucleic acids, a process which is critical and ubiquitous in an extensive array of scientific fields.
Collapse
Affiliation(s)
- Scott M. Berry
- Department of Biomedical Engineering, University of Wisconsin—Madison, 1111 Highland Ave, Rm. 6009, Madison, WI, 53705, USA
| | - Elaine T. Alarid
- Department of Oncology, University of Wisconsin—Madison, 1111 Highland Ave, Madison, WI, 53705, USA
| | - David J. Beebe
- Department of Biomedical Engineering, University of Wisconsin—Madison, 1111 Highland Ave, Rm. 6009, Madison, WI, 53705, USA
- ; Fax: +1 608-265-6905; Tel: +1 608-262-2260
| |
Collapse
|
173
|
Sabella S, Vecchio G, Brunetti V, Cingolani R, Rinaldi R, Pompa PP. Direct PCR analysis of biological samples in disposable plastic microreactors for biochip applications. JOURNAL OF ANALYTICAL CHEMISTRY 2011. [DOI: 10.1134/s1061934811050170] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
174
|
Abstract
BACKGROUND
Centrifugal “lab on a disk” microfluidics is a promising avenue for developing portable, low-cost, automated immunoassays. However, the necessity of incorporating multiple wash steps results in complicated designs that increase the time and sample/reagent volumes needed to run assays and raises the probability of errors. We present proof of principle for a disk-based microfluidic immunoassay technique that processes blood samples without conventional wash steps.
METHODS
Microfluidic disks were fabricated from layers of patterned, double-sided tape and polymer sheets. Sample was mixed on-disk with assay capture beads and labeling antibodies. Following incubation, the assay beads were physically separated from the blood cells, plasma, and unbound label by centrifugation through a density medium. A signal-laden pellet formed at the periphery of the disk was analyzed to quantify concentration of the target analyte.
RESULTS
To demonstrate this technique, the inflammation biomarkers C-reactive protein and interleukin-6 were measured from spiked mouse plasma and human whole blood samples. On-disk processing (mixing, labeling, and separation) facilitated direct assays on 1-μL samples with a 15-min sample-to-answer time, <100 pmol/L limit of detection, and 10% CV. We also used a unique single-channel multiplexing technique based on the sedimentation rate of different size or density bead populations.
CONCLUSIONS
This portable microfluidic system is a promising method for rapid, inexpensive, and automated detection of multiple analytes directly from a drop of blood in a point-of-care setting.
Collapse
Affiliation(s)
- Ulrich Y Schaff
- Biotechnology and Bioengineering Department, Sandia National Laboratories, Livermore, CA 94550
| | - Greg J Sommer
- Biotechnology and Bioengineering Department, Sandia National Laboratories, Livermore, CA 94550
| |
Collapse
|
175
|
Girkin JM, Mohammed MI, Ellis EM. A miniaturised integrated biophotonic point-of-care genotyping system. Faraday Discuss 2011; 149:115-23; discussion 137-57. [PMID: 21413178 DOI: 10.1039/c005271j] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This paper reports the development of a novel genotyping device specifically designed for point-of-care applications. As the results of the human genome project are applied to clinical practice there is an increasing requirement for simple to operate high-speed, potentially low-cost genotyping devices for use in the clinic. The aim of such devices is not to specifically detect a full gene sequence but to monitor the presence of specific Single Nucleotide Polymorphisms (SNPs). The instrument is designed to fulfil this specific clinical requirement. Using a FRET-based assay the instrument completes a full PCR process and then performs a melting point test to determine the exact SNPs present in the sample. Results are presented in which the instrument produces results within 18 min based upon saliva samples provided by the patient. The paper also reports successful results both with purified DNA samples and saliva-based samples which were taken from subjects after experiments deliberately aimed at confusing the instrument.
Collapse
Affiliation(s)
- John M Girkin
- Department of Physics, University of Durham, Durham, DH1 3LE, UK
| | | | | |
Collapse
|
176
|
Julich S, Riedel M, Kielpinski M, Urban M, Kretschmer R, Wagner S, Fritzsche W, Henkel T, Möller R, Werres S. Development of a lab-on-a-chip device for diagnosis of plant pathogens. Biosens Bioelectron 2011; 26:4070-5. [PMID: 21531125 DOI: 10.1016/j.bios.2011.03.035] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2011] [Revised: 03/22/2011] [Accepted: 03/27/2011] [Indexed: 11/18/2022]
Abstract
A lab-on-a-chip system for rapid nucleic acid-based analysis was developed that can be applied for diagnosis of selected Phytophthora species as a first example for use in plant pathology. All necessary polymerase chain reaction process (PCR) and hybridization steps can be performed consecutively within a single chip consisting of two components, an inflexible and a flexible one, with integrated microchannels and microchambers. Data from the microarray is collected from a simple electrical measurement that is based on elementary silver deposition by enzymatical catalyzation. Temperatures in the PCR and in the hybridization zone are managed by two independent Peltier elements. The chip will be integrated in a compact portable system with a pump and power supply for use on site. The specificity of the lab-on-a-chip system could be demonstrated for the tested five Phytophthora species. The two Pythium species gave signals below the threshold. The results of the electrical detection of the microarray correspond to the values obtained with the control method (optical grey scale analysis).
Collapse
Affiliation(s)
- Sandra Julich
- Institute of Photonic Technology (IPHT), Nanobiophotonics Department, Albert-Einstein-Str. 9, 07745 Jena, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
177
|
Rapid screening of phenylketonuria using a CD microfluidic device. J Chromatogr A 2011; 1218:1907-12. [DOI: 10.1016/j.chroma.2011.02.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2010] [Revised: 01/19/2011] [Accepted: 02/01/2011] [Indexed: 11/19/2022]
|
178
|
Liu C, Geva E, Mauk M, Qiu X, Abrams WR, Malamud D, Curtis K, Owen SM, Bau HH. An isothermal amplification reactor with an integrated isolation membrane for point-of-care detection of infectious diseases. Analyst 2011; 136:2069-76. [PMID: 21455542 DOI: 10.1039/c1an00007a] [Citation(s) in RCA: 138] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A simple, point of care, inexpensive, disposable cassette for the detection of nucleic acids extracted from pathogens was designed, constructed, and tested. The cassette utilizes a single reaction chamber for isothermal amplification of nucleic acids. The chamber is equipped with an integrated, flow-through, Flinders Technology Associates (Whatman FTA®) membrane for the isolation, concentration, and purification of DNA and/or RNA. The nucleic acids captured by the membrane are used directly as templates for amplification without elution, thus simplifying the cassette's flow control. The FTA membrane also serves another critical role-enabling the removal of inhibitors that dramatically reduce detection sensitivity. Thermal control is provided with a thin film heater external to the cassette. The amplification process was monitored in real time with a portable, compact fluorescent reader. The utility of the integrated, single-chamber cassette was demonstrated by detecting the presence of HIV-1 in oral fluids. The HIV RNA was reverse transcribed and subjected to loop-mediated, isothermal amplification (LAMP). A detection limit of less than 10 HIV particles was demonstrated. The cassette is particularly suitable for resource poor regions, where funds and trained personnel are in short supply. The cassette can be readily modified to detect nucleic acids associated with other pathogens borne in saliva, urine, and other body fluids as well as in water and food.
Collapse
Affiliation(s)
- Changchun Liu
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, 19104-6315, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
179
|
Biosensor diagnosis of urinary tract infections: a path to better treatment? Trends Pharmacol Sci 2011; 32:330-6. [PMID: 21458868 DOI: 10.1016/j.tips.2011.03.001] [Citation(s) in RCA: 68] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2010] [Revised: 02/28/2011] [Accepted: 03/01/2011] [Indexed: 02/08/2023]
Abstract
Urinary tract infection (UTI) is among the most common bacterial infections and poses a significant healthcare burden. The standard culture-based diagnosis of UTI has a typical delay of two to three days. In the absence of definitive microbiological diagnosis at the point of care, physicians frequently initiate empirical broad-spectrum antibiotic treatment, and this has contributed to the emergence of resistant pathogens. Biosensors are emerging as a powerful diagnostic platform for infectious diseases. Paralleling how blood glucose sensors revolutionized the management of diabetes, and how pregnancy tests are now conducted in the home, biosensors are poised to improve UTI diagnosis significantly. Biosensors are amenable to integration with microfluidic technology for point-of-care (POC) applications. This review focuses on promising biosensor technology for UTI diagnosis, including pathogen identification and antimicrobial susceptibility testing, and hurdles to be surpassed in the translation of biosensor technology from bench to bedside.
Collapse
|
180
|
Dai D, Holder D, Raskin L, Xi C. Separation of the bacterial species, Escherichia coli, from mixed-species microbial communities for transcriptome analysis. BMC Microbiol 2011; 11:59. [PMID: 21418656 PMCID: PMC3076228 DOI: 10.1186/1471-2180-11-59] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2011] [Accepted: 03/22/2011] [Indexed: 11/18/2022] Open
Abstract
Background The study of bacterial species interactions in a mixed-species community can be facilitated by transcriptome analysis of one species in the community using cDNA microarray technology. However, current applications of microarrays are mostly limited to single species studies. The purpose of this study is to develop a method to separate one species, Escherichia coli as an example, from mixed-species communities for transcriptome analysis. Results E. coli cells were separated from a dual-species (E. coli and Stenotrophomonas maltophilia) community using immuno-magnetic separation (IMS). High recovery rates of E. coli were achieved. The purity of E. coli cells was as high as 95.0% separated from suspended mixtures consisting of 1.1 - 71.3% E. coli, and as high as 96.0% separated from biofilms with 8.1% E. coli cells. Biofilms were pre-dispersed into single-cell suspensions. The reagent RNAlater (Ambion, Austin, TX) was used during biofilm dispersion and IMS to preserve the transcriptome of E. coli. A microarray study and quantitative PCR confirmed that very few E. coli genes (only about eight out of 4,289 ORFs) exhibited a significant change in expression during dispersion and separation, indicating that transcriptional profiles of E. coli were well preserved. Conclusions A method based on immuno-magnetic separation (IMS) and application of RNAlater was developed to separate a bacterial species, E. coli as an example, from mixed-species communities while preserving its transcriptome. The method combined with cDNA microarray analysis should be very useful to study species interactions in mixed-species communities.
Collapse
Affiliation(s)
- Dongjuan Dai
- Department of Environmental Health Sciences, University of Michigan, Ann Arbor, MI 48109, USA
| | | | | | | |
Collapse
|
181
|
Shaw KJ, Joyce DA, Docker PT, Dyer CE, Greenway GM, Greenman J, Haswell SJ. Development of a real-world direct interface for integrated DNA extraction and amplification in a microfluidic device. LAB ON A CHIP 2011; 11:443-8. [PMID: 21072429 DOI: 10.1039/c0lc00346h] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Integrated DNA extraction and amplification have been carried out in a microfluidic device using electro-osmotic pumping (EOP) for fluidic control. All the necessary reagents for performing both DNA extraction and polymerase chain reaction (PCR) amplification were pre-loaded into the microfluidic device following encapsulation in agarose gel. Buccal cells were collected using OmniSwabs [Whatman™, UK] and manually added to a chaotropic binding/lysis solution pre-loaded into the microfluidic device. The released DNA was then adsorbed onto a silica monolith contained within the DNA extraction chamber and the microfluidic device sealed using polymer electrodes. The washing and elution steps for DNA extraction were carried out using EOP, resulting in transfer of the eluted DNA into the PCR chamber. Thermal cycling, achieved using a Peltier element, resulted in amplification of the Amelogenin locus as confirmed using conventional capillary gel electrophoresis. It was demonstrated that the PCR reagents could be stored in the microfluidic device for at least 8 weeks at 4 °C with no significant loss of activity. Such methodology lends itself to the production of 'ready-to-use' microfluidic devices containing all the necessary reagents for sample processing, with many obvious applications in forensics and clinical medicine.
Collapse
Affiliation(s)
- Kirsty J Shaw
- Department of Chemistry, University of Hull, Cottingham Road, Hull, UK HU6 7RX
| | | | | | | | | | | | | |
Collapse
|
182
|
Abstract
We have developed a microfluidic device capable of fully integrated sample preparation and gene analysis from crude biosamples such as whole blood. Our platform takes the advantage of the silica superparamagnetic particle based solid phase extraction to develop an all-in-one scheme that performs cell lysis, DNA binding, washing, elution and the PCR in the same reaction chamber. The device also employs a unique reagent loading scheme, allowing efficient preparation of multiple reactions via a single injection channel. In addition, PCR is performed in a droplet-in-oil manner, eliminating the need for chamber sealing. The combination of these design features greatly reduces the complexity in implementing fully integrated lab-on-a-chip systems for genetic detection, facilitating parallel analysis of multiple samples or genes on a single microchip. The capability of the device is demonstrated by performing DNA isolation from the human whole blood sample and analyzing the Rsf-1 gene using the TaqMan probe based gene specific PCR assays.
Collapse
|
183
|
Deféver T, Druet M, Evrard D, Marchal D, Limoges B. Real-Time Electrochemical PCR with a DNA Intercalating Redox Probe. Anal Chem 2011; 83:1815-21. [DOI: 10.1021/ac1033374] [Citation(s) in RCA: 81] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Affiliation(s)
- Thibaut Deféver
- Laboratoire d'Electrochimie Moléculaire, UMR CNRS 7591, Université Paris Diderot, 15, rue Jean-Antoine de Baïf, 75205 Paris Cedex 13, France
| | - Michel Druet
- Laboratoire d'Electrochimie Moléculaire, UMR CNRS 7591, Université Paris Diderot, 15, rue Jean-Antoine de Baïf, 75205 Paris Cedex 13, France
| | - David Evrard
- Laboratoire d'Electrochimie Moléculaire, UMR CNRS 7591, Université Paris Diderot, 15, rue Jean-Antoine de Baïf, 75205 Paris Cedex 13, France
| | - Damien Marchal
- Laboratoire d'Electrochimie Moléculaire, UMR CNRS 7591, Université Paris Diderot, 15, rue Jean-Antoine de Baïf, 75205 Paris Cedex 13, France
| | - Benoit Limoges
- Laboratoire d'Electrochimie Moléculaire, UMR CNRS 7591, Université Paris Diderot, 15, rue Jean-Antoine de Baïf, 75205 Paris Cedex 13, France
| |
Collapse
|
184
|
Liu K, Fan ZH. Thermoplastic microfluidic devices and their applications in protein and DNA analysis. Analyst 2011; 136:1288-97. [PMID: 21274478 DOI: 10.1039/c0an00969e] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Microfluidics is a platform technology that has been used for genomics, proteomics, chemical synthesis, environment monitoring, cellular studies, and other applications. The fabrication materials of microfluidic devices have traditionally included silicon and glass, but plastics have gained increasing attention in the past few years. We focus this review on thermoplastic microfluidic devices and their applications in protein and DNA analysis. We outline the device design and fabrication methods, followed by discussion on the strategies of surface treatment. We then concentrate on several significant advancements in applying thermoplastic microfluidic devices to protein separation, immunoassays, and DNA analysis. Comparison among numerous efforts, as well as the discussion on the challenges and innovation associated with detection, is presented.
Collapse
Affiliation(s)
- Ke Liu
- Interdisciplinary Microsystems Group, Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, Florida 32611-6250, USA
| | | |
Collapse
|
185
|
Min J, Kim JH, Lee Y, Namkoong K, Im HC, Kim HN, Kim HY, Huh N, Kim YR. Functional integration of DNA purification and concentration into a real time micro-PCR chip. LAB ON A CHIP 2011; 11:259-265. [PMID: 20967380 DOI: 10.1039/c0lc00320d] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Microfluidic devices for on-chip amplification of DNA from various biological and environmental samples have gained extensive attention over the past decades with many applications including molecular diagnostics of disease, food safety and biological warfare testing. But the integration of sample preparation functions into the chip remains a major hurdle for practical application of the chip-based diagnostic system. We present a PCR-based molecular diagnostic device comprised of a microfabricated chip and a centrifugal force assisted liquid handling tube (CLHT) that is designed to carry out concentration and purification of DNA and subsequent amplification of the target gene in a single chip. The reaction chamber of the chip contains an array of pillar structures to increase the surface area for capturing DNA from a raw sample of macro volume in the presence of kosmotropic agents. The CLHT was designed to provide an effective interface between sample preparation and the microfluidic PCR chip. We have characterized the effect of various fluidic parameters including DNA capture, amplification efficiency and centrifugal pressure generated upon varying sample volume. We also evaluated the performance of this system for quantitative detection of E. coli O157:H7. From the samples containing 10(1) to 10(4) cells per mL, the C(T) value linearly increased from 25.1 to 34.8 with an R(2) value greater than 0.98. With the effectiveness and simplicity of operation, this system will provide an effective interface between macro and micro systems and bridge chip-based molecular diagnosis with practical applications.
Collapse
Affiliation(s)
- Junhong Min
- College of Bionano Technology, Kyungwon University, Seongnam, 461-701, Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
186
|
Weak solvent based chip lamination and characterization of on-chip valve and pump. Biomed Microdevices 2011; 12:821-32. [PMID: 20526680 DOI: 10.1007/s10544-010-9436-z] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
Using polystyrene as a fabrication material and pure acetonitrile as a bonding solvent, we have developed an innovative and inexpensive weak-solvent-based chip lamination process to produce highly functional, completely plastic, microfluidic chips with a 3-layer structure. This simple, scalable and rapid method allows active components, such as multiple valves and pumps, to be constructed on chip with a thin, deflectable film as the middle layer sandwiched between two polystyrene layers. Our irreversible bonding method achieves uniform lamination under mild conditions (35-45 degrees C and 10-50 KPa) without damage to the underlying micro-features. The on-chip valve and pump structures have been systematically characterized and the pumping rate has been compared against theoretical rates predicted by mathematical modeling studies. A wide range of pumping rates (0.33-10 microL/s) can be achieved, with the integral pumps maintaining a constant pumping rate and depending on pumping frequency and pump diaphragm size. Valve leakage of less than 0.02 microL/min is noted under pressures of 41 kPa. Utilizing various configurations of on-chip valves and pumps, the fully automated flow control of an integrated chip for sample lysis, nucleic acid purification and PCR is demonstrated. The present technology and chip have been heavily evaluated internally and externally for rapid biomedical diagnosis of HPV, HIV, etc., and they are currently in the process of commercialization.
Collapse
|
187
|
Abstract
The development of microfluidics and its utilization in a myriad of applications has grown exponentially over the past 15 years. One area that has benefited from the great strides in fabrication of microelectromechanical systems (MEMS) is separations chemistry. Most studies have focused on small molecule and DNA separations; few on protein chromatographic techniques on microchips. This review details recent developments in protein separations on microfluidic platforms and how MEMS have the potential for revolutionizing protein chromatography.
Collapse
Affiliation(s)
- Frank A Gomez
- Department of Chemistry and Biochemistry, California State University, Los Angeles, CA, USA
| |
Collapse
|
188
|
Setterington EB, Alocilja EC. Rapid electrochemical detection of polyaniline-labeled Escherichia coli O157:H7. Biosens Bioelectron 2011; 26:2208-14. [DOI: 10.1016/j.bios.2010.09.036] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2010] [Revised: 09/16/2010] [Accepted: 09/18/2010] [Indexed: 11/25/2022]
|
189
|
GAO X, TANAKA Y, SUGII Y, MAWATARI K, KITAMORI T. Basic Structure and Cell Culture Condition of a Bioartificial Renal Tubule on Chip towards a Cell-based Separation Microdevice. ANAL SCI 2011; 27:907-12. [DOI: 10.2116/analsci.27.907] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Xiaofang GAO
- Department of Bioengineering, School of Engineering, The University of Tokyo
| | - Yo TANAKA
- Department of Applied Chemistry, School of Engineering, The University of Tokyo
- Core Research for Evolutional Science and Technology (CREST), Japan Science and Technology Agency (JST)
- Quantitative Biology Center, RIKEN Kobe Institute
| | - Yasuhiko SUGII
- Department of Applied Chemistry, School of Engineering, The University of Tokyo
- Core Research for Evolutional Science and Technology (CREST), Japan Science and Technology Agency (JST)
| | - Kazuma MAWATARI
- Department of Applied Chemistry, School of Engineering, The University of Tokyo
- Core Research for Evolutional Science and Technology (CREST), Japan Science and Technology Agency (JST)
| | - Takehiko KITAMORI
- Department of Bioengineering, School of Engineering, The University of Tokyo
- Department of Applied Chemistry, School of Engineering, The University of Tokyo
- Core Research for Evolutional Science and Technology (CREST), Japan Science and Technology Agency (JST)
| |
Collapse
|
190
|
|
191
|
Kivlehan F, Mavré F, Talini L, Limoges B, Marchal D. Real-time electrochemical monitoring of isothermal helicase-dependent amplification of nucleic acids. Analyst 2011; 136:3635-42. [DOI: 10.1039/c1an15289k] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
192
|
Wang AB, Cheng CW, Lin IC, Lu FY, Tsai HJ, Lin CC, Yang CH, Pan PT, Kuan CC, Chen YC, Lin YW, Chang CN, Wu YH, Kurniawan T, Lin CW, Wo AM, Chen LC. A novel DNA selection and direct extraction process and its application in DNA recombination. Electrophoresis 2010; 32:423-30. [PMID: 21298668 DOI: 10.1002/elps.201000449] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2010] [Revised: 10/14/2010] [Accepted: 11/03/2010] [Indexed: 11/12/2022]
Abstract
In the conventional bench-top approach, the DNA recombination process is time- and effort-consuming due to laborious procedures lasting from several hours to a day. A novel DNA selection and direct extraction process has been proposed, integrated and tested on chip. The integrative microfluidic chip can perform the whole procedure of DNA recombination, including DNA digestion, gel electrophoresis, DNA extraction and insert-vector ligation within 1 h. In this high-throughput design, the manual gel cutting was replaced by an automatic processing system that performed high-quality and high-recovery efficiency in DNA extraction process. With no need of gel-dissolving reagents and manipulation, the application of selection and direct extraction process could significantly eliminate the risks from UV and EtBr and also facilitate DNA recombination. Reliable output with high success rate of cloning has been achieved with a significant reduction in operational hazards, required materials, efforts and time.
Collapse
Affiliation(s)
- An-Bang Wang
- Institute of Applied Mechanics, National Taiwan University, Taipei, Taiwan.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
193
|
Hopwood AJ, Hurth C, Yang J, Cai Z, Moran N, Lee-Edghill JG, Nordquist A, Lenigk R, Estes MD, Haley JP, McAlister CR, Chen X, Brooks C, Smith S, Elliott K, Koumi P, Zenhausern F, Tully G. Integrated microfluidic system for rapid forensic DNA analysis: sample collection to DNA profile. Anal Chem 2010; 82:6991-9. [PMID: 20704389 DOI: 10.1021/ac101355r] [Citation(s) in RCA: 83] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
We demonstrate a conduit for the delivery of a step change in the DNA analysis process: A fully integrated instrument for the analysis of multiplex short tandem repeat DNA profiles from reference buccal samples is described and is suitable for the processing of such samples within a forensic environment such as a police custody suite or booking office. The instrument is loaded with a DNA processing cartridge which incorporates on-board pumps and valves which direct the delivery of sample and reagents to the various reaction chambers to allow DNA purification, amplification of the DNA by PCR, and collection of the amplified product for delivery to an integral CE chip. The fluorescently labeled product is separated using micro capillary electrophoresis with a resolution of 1.2 base pairs (bp) allowing laser induced fluorescence-based detection of the amplified short tandem repeat fragments and subsequent analysis of data to produce a DNA profile which is compatible with the data format of the UK DNA database. The entire process from taking the sample from a suspect, to database compatible DNA profile production can currently be achieved in less than 4 h. By integrating such an instrument and microfluidic cartridge with the forensic process, we believe it will be possible in the near future to process a DNA sample taken from an individual in police custody and compare the profile with the DNA profiles held on a DNA Database in as little as 3 h.
Collapse
Affiliation(s)
- Andrew J Hopwood
- Research and Development, Forensic Science Service, Trident Court 2960 Solihull Parkway, Birmingham Business Park, Birmingham, UK B37 7YN.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
194
|
Hurth C, Smith SD, Nordquist AR, Lenigk R, Duane B, Nguyen D, Surve A, Hopwood AJ, Estes MD, Yang J, Cai Z, Chen X, Lee-Edghill JG, Moran N, Elliott K, Tully G, Zenhausern F. An automated instrument for human STR identification: design, characterization, and experimental validation. Electrophoresis 2010; 31:3510-7. [PMID: 20931618 DOI: 10.1002/elps.201000305] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The microfluidic integration of an entire DNA analysis workflow on a fully integrated miniaturized instrument is reported using lab-on-a-chip automation to perform DNA fingerprinting compatible with CODIS standard relevant to the forensic community. The instrument aims to improve the cost, duration, and ease of use to perform a "sample-to-profile" analysis with no need for human intervention. The present publication describes the operation of the three major components of the system: the electronic control components, the microfluidic cartridge and CE microchip, and the optical excitation/detection module. Experimental details are given to characterize the level of performance, stability, reliability, accuracy, and sensitivity of the prototype system. A typical temperature profile from a PCR amplification process and an electropherogram of a commercial size standard (GeneScan 500™, Applied Biosystems) separation are shown to assess the relevance of the instrument to forensic applications. Finally, we present a profile from an automated integrated run where lysed cells from a buccal swab were introduced in the system and no further human intervention was required to complete the analysis.
Collapse
Affiliation(s)
- Cedric Hurth
- Center for Applied NanoBioscience and Medicine, The University of Arizona College of Medicine, Phoenix, AZ 85004, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
195
|
Jensen EC, Zeng Y, Kim J, Mathies RA. Microvalve Enabled Digital Microfluidic Systems for High Performance Biochemical and Genetic Analysis. ACTA ACUST UNITED AC 2010; 15:455-463. [PMID: 21218162 DOI: 10.1016/j.jala.2010.08.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
Microfluidic devices offer unparalleled capability for digital microfluidic automation of sample processing and complex assay protocols in medical diagnostic and research applications. In our own work, monolithic membrane valves have enabled the creation of two platforms that precisely manipulate discrete, nanoliter-scale volumes of sample. The digital microfluidic Automaton uses two-dimensional microvalve arrays to combinatorially process nanoliter-scale sample volumes. This programmable system enables rapid integration of diverse assay protocols using a universal processing architecture. Microfabricated emulsion generator array (MEGA) devices integrate actively controlled 3-microvalve pumps to enable on-demand generation of uniform droplets for statistical encapsulation of microbeads and cells. A MEGA device containing 96 channels confers the capability of generating up to 3.4 × 10(6) nanoliter-volume droplets per hour for ultrahigh-throughput detection of rare mutations in a vast background of normal genotypes. These novel digital microfluidic platforms offer significant enhancements in throughput, sensitivity, and programmability for automated sample processing and analysis.
Collapse
Affiliation(s)
- Erik C Jensen
- Biophysics Graduate Group, University of California, Berkeley, CA 94720
| | | | | | | |
Collapse
|
196
|
Xu G, Hsieh TM, Lee DYS, Ali EM, Xie H, Looi XL, Koay ESC, Li MH, Ying JY. A self-contained all-in-one cartridge for sample preparation and real-time PCR in rapid influenza diagnosis. LAB ON A CHIP 2010; 10:3103-3111. [PMID: 20865195 DOI: 10.1039/c005265e] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Herein we present a fully automated system with pseudo-multiplexing capability for rapid infectious disease diagnosis. The all-in-one system was comprised of a polymer cartridge, a miniaturized thermal cycler, 1-color, 3-chamber fluorescence detectors for real-time reverse transcription polymerase chain reaction (RRT-PCR), and a pneumatic fluidic delivery unit consisting of two pinch-valve manifolds and two pneumatic pumps. The disposable, self-contained cartridge held all the necessary reagents for viral RNA purification and reverse transcription polymerase chain reaction (RT-PCR) detection, which took place all within the completely sealed cartridge. The operator only needed to pipette the patient's sample with lysis buffer into the cartridge, and the system would automatically perform the entire sample preparation and diagnosis within 2.5 h. We have successfully employed this system for seasonal influenza A H1N1 typing and sub-typing, obtaining comparable sensitivity as the experiments conducted using manual RNA extraction and commercial thermal cycler. A minimum detectable virus loading of 100 copies per μl has been determined by serial dilution experiments. This all-in-one desktop system would be suitable for decentralized disease diagnosis at immigration check points and outpatient clinics, and would not require highly skilled operators.
Collapse
Affiliation(s)
- Guolin Xu
- Institute of Bioengineering and Nanotechnology, The Nanos, Singapore
| | | | | | | | | | | | | | | | | |
Collapse
|
197
|
Bahi MM, Tsaloglou MN, Mowlem M, Morgan H. Electroporation and lysis of marine microalga Karenia brevis for RNA extraction and amplification. J R Soc Interface 2010; 8:601-8. [PMID: 21084344 DOI: 10.1098/rsif.2010.0445] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
Abstract
We describe here a simple device for dielectrophoretic concentration of marine microalga Karenia brevis non-motile cells, followed by electric field-mediated lysis for RNA extraction. The lysate was purified using magnetic beads and pure RNA extracted. RNA quality was assessed off-chip by nucleic acid sequence-based amplification and the optimum conditions for lysis were determined. This procedure will form part of an integrated microfluidic system that is being developed with sub-systems for performing cell concentration and lysis, RNA extraction/purification and real-time quantitative RNA detection. The integrated system and its components could be used for a large range of applications including in situ harmful algal bloom detection, transcriptomics and point-of-care diagnostics.
Collapse
Affiliation(s)
- M M Bahi
- Sensors Development Group, National Oceanography Centre, Southampton, UK.
| | | | | | | |
Collapse
|
198
|
Xue Y, Wang H, Zhao Y, Dai L, Feng L, Wang X, Lin T. Magnetic liquid marbles: a "precise" miniature reactor. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2010; 22:4814-8. [PMID: 20809512 DOI: 10.1002/adma.201001898] [Citation(s) in RCA: 194] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Affiliation(s)
- Yuhua Xue
- Centre for Material and Fibre Innovation, Deakin University, Geelong, VIC 3217, Australia
| | | | | | | | | | | | | |
Collapse
|
199
|
Garcia-Cordero JL, Kurzbuch D, Benito-Lopez F, Diamond D, Lee LP, Ricco AJ. Optically addressable single-use microfluidic valves by laser printer lithography. LAB ON A CHIP 2010; 10:2680-7. [PMID: 20740236 DOI: 10.1039/c004980h] [Citation(s) in RCA: 59] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
We report the design, fabrication, and characterization of practical microfluidic valves fabricated using laser printer lithography. These optofluidic valves are opened by directing optical energy from a solid-state laser, with similar power characteristics to those used in CD/DVD drives, to a spot of printed toner where localized heating melts an orifice in the polymer layer in as little as 500 ms, connecting previously isolated fluidic components or compartments. Valve functionality, response time, and laser input energy dependence of orifice size are reported for cyclo-olefin polymer (COP) and polyethylene terephthalate (PET) films. Implementation of these optofluidic valves is demonstrated on pressure-driven and centrifugal microfluidic platforms. In addition, these "one-shot" valves comprise a continuous polymer film that hermetically isolates on-chip fluid volumes within fluidic devices using low-vapor-permeability materials; we confirmed this for a period of one month. The fabrication and integration of optofluidic valves are compatible with a range of polymer microfabrication technologies and should facilitate the development of fully integrated, reconfigurable, and automated lab-on-a-chip systems, particularly when reagents must be stored on chip for extended periods, e.g. for medical diagnostic devices, lab-on-a-chip synthetic systems, or hazardous biochemical analysis platforms.
Collapse
|
200
|
Chen D, Mauk M, Qiu X, Liu C, Kim J, Ramprasad S, Ongagna S, Abrams WR, Malamud D, Corstjens PLAM, Bau HH. An integrated, self-contained microfluidic cassette for isolation, amplification, and detection of nucleic acids. Biomed Microdevices 2010; 12:705-19. [PMID: 20401537 DOI: 10.1007/s10544-010-9423-4] [Citation(s) in RCA: 145] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
A self-contained, integrated, disposable, sample-to-answer, polycarbonate microfluidic cassette for nucleic acid-based detection of pathogens at the point of care was designed, constructed, and tested. The cassette comprises on-chip sample lysis, nucleic acid isolation, enzymatic amplification (polymerase chain reaction and, when needed, reverse transcription), amplicon labeling, and detection. On-chip pouches and valves facilitate fluid flow control. All the liquids and dry reagents needed for the various reactions are pre-stored in the cassette. The liquid reagents are stored in flexible pouches formed on the chip surface. Dry (RT-)PCR reagents are pre-stored in the thermal cycling, reaction chamber. The process operations include sample introduction; lysis of cells and viruses; solid-phase extraction, concentration, and purification of nucleic acids from the lysate; elution of the nucleic acids into a thermal cycling chamber and mixing with pre-stored (RT-)PCR dry reagents; thermal cycling; and detection. The PCR amplicons are labeled with digoxigenin and biotin and transmitted onto a lateral flow strip, where the target analytes bind to a test line consisting of immobilized avidin-D. The immobilized nucleic acids are labeled with up-converting phosphor (UCP) reporter particles. The operation of the cassette is automatically controlled by an analyzer that provides pouch and valve actuation with electrical motors and heating for the thermal cycling. The functionality of the device is demonstrated by detecting the presence of bacterial B.Cereus, viral armored RNA HIV, and HIV I virus in saliva samples. The cassette and actuator described here can be used to detect other diseases as well as the presence of bacterial and viral pathogens in the water supply and other fluids.
Collapse
Affiliation(s)
- Dafeng Chen
- Department of Mechanical Engineering and Applied Mechanics, University of Pennsylvania, Philadelphia, PA 19104, USA
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|