1
|
Gómez-Pastora J, Kim J, Multanen V, Weigand M, Walters NA, Reátegui E, Palmer AF, Yazer MH, Zborowski M, Chalmers JJ. Intrinsically magnetic susceptibility in human blood and its potential impact on cell separation: Non-classical and intermediate monocytes have the strongest magnetic behavior in fresh human blood. Exp Hematol 2021; 99:21-31.e5. [PMID: 34015390 DOI: 10.1016/j.exphem.2021.05.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2021] [Revised: 05/10/2021] [Accepted: 05/11/2021] [Indexed: 11/28/2022]
Abstract
The presence of iron in circulating monocytes is well known as they play an essential role in iron recycling. It has been demonstrated that the iron content of blood cells can be measured through their magnetic behavior; however, the magnetic properties of different monocyte subtypes remain unknown. In this study we report, for the first time, the magnetic behavior of classical, intermediate and non-classical monocytes, which may be related to their iron storage capacity. The magnetic properties of monocytes were compared with those of other blood cells, such as lymphocytes and red blood cells in the oxyhemoglobin and methemoglobin states, and a cancer cell type. For this analysis, we used an instrument referred to as a Cell Tracking Velocimetry (CTV), which quantitatively characterizes the magnetic behavior of biological entities. Our results revealed that significant fractions of the intermediate and non-classical monocytes (up to 59% and 65% depending on the sample, respectively) have paramagnetic properties, suggesting their higher iron storage capacities. Moreover, our findings have implications for the immunomagnetic separation industry; we propose that negative magnetic isolation techniques for recovering monocytes from blood should be used with caution, as it is possible to lose magnetic monocytes when using this technique.
Collapse
Affiliation(s)
- Jenifer Gómez-Pastora
- William G. Lowrie Department of Chemical and Biomolecular Engineering, Ohio State University, Columbus, OH
| | - James Kim
- William G. Lowrie Department of Chemical and Biomolecular Engineering, Ohio State University, Columbus, OH
| | - Victor Multanen
- William G. Lowrie Department of Chemical and Biomolecular Engineering, Ohio State University, Columbus, OH
| | - Mitchell Weigand
- William G. Lowrie Department of Chemical and Biomolecular Engineering, Ohio State University, Columbus, OH
| | - Nicole A Walters
- William G. Lowrie Department of Chemical and Biomolecular Engineering, Ohio State University, Columbus, OH
| | - Eduardo Reátegui
- William G. Lowrie Department of Chemical and Biomolecular Engineering, Ohio State University, Columbus, OH
| | - Andre F Palmer
- William G. Lowrie Department of Chemical and Biomolecular Engineering, Ohio State University, Columbus, OH
| | - Mark H Yazer
- Department of Pathology, University of Pittsburgh, Pittsburgh, PA
| | - Maciej Zborowski
- Department of Biomedical Engineering, Cleveland Clinic, Cleveland, OH
| | - Jeffrey J Chalmers
- William G. Lowrie Department of Chemical and Biomolecular Engineering, Ohio State University, Columbus, OH.
| |
Collapse
|
2
|
Abstract
Hepatitis B virus (HBV) infection is a worldwide health problem, with approximately one third of populations have been infected, among which 3-5% of adults and more than 90% of children developed to chronic HBV infection. Host immune factors play essential roles in the outcome of HBV infection. Thus, ineffective immune response against HBV may result in persistent virus replications and liver necroinflammations, then lead to chronic HBV infection, liver cirrhosis, and even hepatocellular carcinoma. Cytokine balance was shown to be an important immune characteristic in the development and progression of hepatitis B, as well as in an effective antiviral immunity. Large numbers of cytokines are not only involved in the initiation and regulation of immune responses but also contributing directly or indirectly to the inhibition of virus replication. Besides, cytokines initiate downstream signaling pathway activities by binding to specific receptors expressed on the target cells and play important roles in the responses against viral infections and, therefore, might affect susceptibility to HBV and/or the natural course of the infection. Since cytokines are the primary causes of inflammation and mediates liver injury after HBV infection, we have discussed recent advances on the roles of various cytokines [including T helper type 1 cells (Th1), Th2, Th17, regulatory T cells (Treg)-related cytokines] in different phases of HBV infection and cytokine-related mechanisms for impaired viral control and liver damage during HBV infection. We then focus on experimental therapeutic applications of cytokines to gain a better understanding of this newly emerging aspect of disease pathogenesis.
Collapse
|
3
|
Chalmers, JJ, Lowrie WG. Magnetic, Batch Separation. Methods Cell Biol 2012. [DOI: 10.1016/b978-0-12-405914-6.00010-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
4
|
Chalmers JJ, Xiong Y, Jin X, Shao M, Tong X, Farag S, Zborowski M. Quantification of non-specific binding of magnetic micro- and nanoparticles using cell tracking velocimetry: Implication for magnetic cell separation and detection. Biotechnol Bioeng 2010; 105:1078-93. [PMID: 20014141 DOI: 10.1002/bit.22635] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The maturation of magnetic cell separation technology places increasing demands on magnetic cell separation performance. While a number of factors can cause sub-optimal performance, one of the major challenges can be non-specific binding of magnetic nano- or microparticles to non-targeted cells. Depending on the type of separation, this non-specific binding can have a negative effect on the final purity, the recovery of the targeted cells, or both. In this work, we quantitatively demonstrate that non-specific binding of magnetic nanoparticles can impart a magnetization to cells such that these cells can be retained in a separation column and thus negatively impact the purity of the final product and the recovery of the desired cells. Through experimental data and theoretical arguments, we demonstrate that the number of MACS magnetic particles needed to impart a magnetization that is sufficient to cause non-targeted cells to be retained in the column to be on the order of 500-1,000 nanoparticles. This number of non-specifically bound particles was demonstrated experimentally with an instrument, cell tracking velocimeter, CTV, and it is demonstrated that the sensitivity of the CTV instrument for Fe atoms contained in magnetic nanoparticles on the order of 1 x 10(-15) g/mL of Fe.
Collapse
Affiliation(s)
- J J Chalmers
- William G. Lowrie Department of Chemical and Biomolecular Engineering, The Ohio State University, 140 West 19th Avenue, Columbus, OH 43210, USA.
| | | | | | | | | | | | | |
Collapse
|
5
|
Gijs MAM, Lacharme F, Lehmann U. Microfluidic applications of magnetic particles for biological analysis and catalysis. Chem Rev 2010; 110:1518-63. [PMID: 19961177 DOI: 10.1021/cr9001929] [Citation(s) in RCA: 368] [Impact Index Per Article: 26.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Martin A M Gijs
- Laboratory of Microsystems, Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne EPFL, Switzerland.
| | | | | |
Collapse
|
6
|
Jing Y, Moore LR, Williams PS, Chalmers JJ, Farag SS, Bolwell B, Zborowski M. Blood progenitor cell separation from clinical leukapheresis product by magnetic nanoparticle binding and magnetophoresis. Biotechnol Bioeng 2007; 96:1139-54. [PMID: 17009321 DOI: 10.1002/bit.21202] [Citation(s) in RCA: 86] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Positive selection of CD34+ blood progenitor cells from circulation has been reported to improve patient recovery in applications of autologous transplantation. Current magnetic separation methods rely on cell capture and release on solid supports rather than sorting from flowing suspensions, which limits the range of therapeutic applications and the process scale up. We tested CD34+ cell immunomagnetic labeling and isolation from fresh leukocyte fraction of peripheral blood (leukapheresis) using the continuous quadrupole magnetic flow sorter (QMS), consisting of a flow channel (SHOT, Greenville, IN) and a quadrupole magnet with a maximum field intensity (B(o)) of 1.42 T and a mean force field strength (S(m)) of 1.45 x 10(8) TA/m(2). Both the sample magnetophoretic mobility (m) and the inlet and outlet flow patterns highly affect the QMS performance. Seven commercial progenitor cell labeling reagent combinations were quantitatively evaluated by measuring magnetophoretic mobility of a high CD34 expression cell line, KG-1a, using the cell tracking velocimeter (CTV). The CD34 Progenitor Cell Isolation Kit (Miltenyi Biotec, Bergisch Gladbach, Germany) showed the strongest labeling of KG-1a cells and was selected for progenitor cell enrichment from 11 fresh and 11 cryopreserved clinical leukapheresis samples derived from different donors. The CD34+ cells were isolated with a purity of 60-96%, a recovery of 18-60%, an enrichment rate of 12-169, and a throughput of (1.7-9.3) x 10(4) cells/s. The results also showed a highly regular dependence of the QMS performance on the flow conditions that agreed with the theoretical predictions based on the CD34+ cell magnetophoretic mobility.
Collapse
Affiliation(s)
- Ying Jing
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Ave., Cleveland, Ohio 44195, USA
| | | | | | | | | | | | | |
Collapse
|
7
|
Tong X, Yang L, Lang JC, Zborowski M, Chalmers JJ. Application of immunomagnetic cell enrichment in combination with RT-PCR for the detection of rare circulating head and neck tumor cells in human peripheral blood. CYTOMETRY PART B-CLINICAL CYTOMETRY 2007; 72:310-23. [PMID: 17205568 DOI: 10.1002/cyto.b.20177] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Detection of rare, circulating tumor cells (CTC's) in human peripheral blood is a potential indicator of prognosis and diagnosis in oncology. Typical methods to detect these CTC's are either by immunocytochemistry (ICCS) or RT-PCR. However without accurate, rapid, and reproducible enrichment processes, these detection techniques are labor intensive and/or unreliable. In this article, a repeatable enrichment process that included a flow-through immunomagnetic cell separation system, the quadrupole magnetic sorter (QMS) was optimized with the aid of a statistical analysis software package. The QMS was operated in a negative mode of operation by immunomagnetically targeting normal human peripheral blood lymphocytes (PBL) through the CD45 surface marker. Three head and neck squamous carcinoma cell lines (HNSCC), Detroit-562, SCC-4, and CAL-27, were used to determine the sensitivity of RT-PCR for the epidermal growth factor receptor (EGFR) in spiked PBL. The detection purity needed for detection was found to be one cell in 10(4), one cell in 10(3), and one cell in 10(5) for the Detroit-562, SCC-4, and CAL-27, respectively. The actual number of cancer cells needed for RT-PCR detection ranged from 30 to 1 cell. To mimic the potential concentration of rare CTC present in peripheral blood of cancer patients, the spiking concentration was chosen to be one cancer cell per 10(5) total leukocytes from healthy donors. Using a single step immunomagnetic labeling, the final, optimized enrichment process produced a 57.6 +/- 30.3-fold (n = 6) enrichment of the rare cancer cells with a final cancer cell recovery of (77.8 +/- 6.6)%.
Collapse
Affiliation(s)
- Xiaodong Tong
- Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, Ohio 43210, USA
| | | | | | | | | |
Collapse
|
8
|
Zhang H, Williams PS, Zborowski M, Chalmers JJ. Binding affinities/avidities of antibody-antigen interactions: quantification and scale-up implications. Biotechnol Bioeng 2006; 95:812-29. [PMID: 16937410 DOI: 10.1002/bit.21024] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Bioaffinity interactions have been, and continue to be, successfully adapted from nature for use in separation and detection applications. It has been previously reported that the magnetophoretic mobility of labeled cells show a saturation type phenomenon as a function of the concentration of the free antibody-magnetic nanoparticle conjugate which is consistent with other reports of antibody-fluorophore binding. Starting with the standard antibody-antigen relationship, a model was developed which takes into consideration multi-valence interactions, and various attributes of flow cytometry (FCM) and cell tracking velocimetry (CTV) measurements to determine both the apparent dissociation constant and the antibody-binding capacity (ABC) of a cell. This model was then evaluated on peripheral blood lymphocytes (PBLs) labeled with anti CD3 antibodies conjugated to FITC, PE, or DM (magnetic nanoparticles). Reasonable agreements between the model and the experiments were obtained. In addition, estimates of the limitation of the number of magnetic nanoparticles that can bind to a cell as a result of steric hinderance was consistent with measured values of magnetophoretic mobility. Finally, a scale-up model was proposed and tested which predicts the amount of antibody conjugates needed to achieve a given level of saturation as the total number of cells reaches 10(10), the number of cells needed for certain clinical applications, such as T-cell depletions for mismatched bone marrow transplants.
Collapse
Affiliation(s)
- Huading Zhang
- Department of Chemical and Biomolecular Engineering, The Ohio State University, 140 W 19th Ave., Columbus, Ohio 43210, USA
| | | | | | | |
Collapse
|
9
|
Lara O, Tong X, Zborowski M, Farag SS, Chalmers JJ. Comparison of two immunomagnetic separation technologies to deplete T cells from human blood samples. Biotechnol Bioeng 2006; 94:66-80. [PMID: 16518837 DOI: 10.1002/bit.20807] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
The objective of this study was to compare the performance of two immunomagnetic separation technologies to deplete T cells from buffy coats of human blood. Specifically, two versions of the commercial MACS(R) Technology: MiniMACS and SuperMACS, and a prototype, flow-through system, the QMS, were evaluated. Peripheral blood mononuclear leukocytes (PBL) were isolated from buffy coats and an immunomagnetic separation of CD3(+) cells was conducted using company and optimized labeling protocols. To mimic peripheral blood containing bone marrow purged hematopoietic stem cells, HSC, CD34 expressing-cells (KG1a) were spiked into PBL prior to T-cell depletion once optimized depletion conditions were determined. Once the labeling protocol was optimized, the MiniMACS system performed well by producing a highly enriched CD3(+) fraction, and a respectable level of depletion of T cells and recovery of KG1a cells in the depleted fraction; an average log(10) depletion of T cells of 2.88 +/- 0.17 and an average recovery of the KG1a cells of 60.8 +/- 5.94% (n = 14). The performance of the SuperMACS system was very similar with an average log(10) depletion of T cells of 2.89 +/- 0.22 and an average recovery of KG1a of 63.1 +/- 8.55% (n = 10). In contrast, the QMS system produced an average log(10) depletion of T cells of 3.98 +/- 0.33 (n = 16) with a corresponding average recovery of 57.9 +/- 16.6% of the spiked CD34+ cells. The aforementioned QMS performance values were obtained using sorting speeds ranging from 2.5 x 10(4) to 1.7 x 10(5) cells per second. It is suggested that the lack of a 100% recovery of the unlabeled KG1a cells is the result of a previously reported "drafting" phenomena which pulls unlabeled cells in the direction of the magnetically labeled cells thereby resulting in loss of the unlabeled cells.
Collapse
Affiliation(s)
- Oscar Lara
- Department of Chemical and Biomolecular Engineering, The Ohio State University, 120 Koffolt Laboratories, 140 W. 19th Avenue, Columbus, 43210, USA
| | | | | | | | | |
Collapse
|
10
|
Higuchi A, Iizuka A, Gomei Y, Miyazaki T, Sakurai M, Matsuoka Y, Natori SH. Separation of CD34+ cells from human peripheral blood through polyurethane foaming membranes. J Biomed Mater Res A 2006; 78:491-9. [PMID: 16736487 DOI: 10.1002/jbm.a.30729] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Cell separation from peripheral blood was investigated using polyurethane (PU) foaming membranes and PU membranes (pore size, 5 or 12 mum) at different blood permeation speeds. Permeation ratio of hematopoietic stem cells (CD34(+) cells) through the PU membranes was the lowest among the blood cells at any blood permeation speed. This is thought to be because CD34(+) cells are more adhesive than red blood cells (RBCs), platelets, T cells, and B cells. Primitive hematopoietic stem and progenitor cells tend to adhere to the surface of mature blood cells, because of the high expression of cell-adhesion molecules on the surface of the cells. Human serum albumin solution was exposed to PU-COOH membranes to detach adhered cells from the surface of the membranes, allowing isolation of CD34(+) cells and reduction of RBCs in the permeate solution. Most purified CD34(+) cells (high recovery ratio of CD34(+) cells divided by recovery ratio of RBCs) were obtained in the recovery process using PU-COOH membranes (pore size, 5.2 microm) at a permeation speed of 0.3-1 mL/min.
Collapse
Affiliation(s)
- Akon Higuchi
- Department of Applied Chemistry, Seikei University, 3-1 Kichijoji Kitamachi 3, Musashino, Tokyo 180-8633, Japan.
| | | | | | | | | | | | | |
Collapse
|
11
|
van Hee P, Hoeben MA, van der Lans RGJM, van der Wielen LAM. Strategy for selection of methods for separation of bioparticles from particle mixtures. Biotechnol Bioeng 2006; 94:689-709. [PMID: 16570310 DOI: 10.1002/bit.20885] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
The desired product of bioprocesses is often produced in particulate form, either as an inclusion body (IB) or as a crystal. Particle harvesting is then a crucial and attractive form of product recovery. Because the liquid phase often contains other bioparticles, such as cell debris, whole cells, particulate biocatalysts or particulate by-products, the recovery of product particles is a complex process. In most cases, the particulate product is purified using selective solubilization or extraction. However, if selective particle recovery is possible, the already high purity of the particles makes this downstream process more favorable. This work gives an overview of typical bioparticle mixtures that are encountered in industrial biotechnology and the various driving forces that may be used for particle-particle separation, such as the centrifugal force, the magnetic force, the electric force, and forces related to interfaces. By coupling these driving forces to the resisting forces, the limitations of using these driving forces with respect to particle size are calculated. It shows that centrifugation is not a general solution for particle-particle separation in biotechnology because the particle sizes of product and contaminating particles are often very small, thus, causing their settling velocities to be too low for efficient separation by centrifugation. Examples of such separation problems are the recovery of IBs or virus-like particles (VLPs) from (microbial) cell debris. In these cases, separation processes that use electrical forces or fluid-fluid interfaces show to have a large potential for particle-particle separation. These methods are not yet commonly applied for large-scale particle-particle separation in biotechnology and more research is required on the separation techniques and on particle characterization to facilitate successful application of these methods in industry.
Collapse
Affiliation(s)
- P van Hee
- Department of Biotechnology, Delft University of Technology Julianalaan 67, 2628 BC Delft, The Netherlands.
| | | | | | | |
Collapse
|
12
|
Leigh DR, Steinert S, Moore LR, Chalmers JJ, Zborowski M. Cell tracking velocimetry as a tool for defining saturation binding of magnetically conjugated antibodies. Cytometry A 2005; 66:103-8. [PMID: 15973696 DOI: 10.1002/cyto.a.20155] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
BACKGROUND Continuous flow immunomagnetic separation is an attractive alternative to current batch mode immunomagnetic separation methods because it is capable of high sorting speeds at mild cell conditions, and grants the operator better control of separation process. The control of the separation is dependent on knowledge of the amount of magnetic label attached to the cell (magnetic labeling intensity), however. Determination of the magnetic labeling is accomplished by measuring cell magnetophoretic mobility using a newly developed technique of Cell Tracking Velocimetry (CTV). METHODS Flow cytometry was used to define the antibody binding characteristics of a fluorescently tagged primary antibody. Subsequently, CTV was used to measure antibody-binding characteristics of a magnetically tagged secondary antibody. RESULTS The results of this study show that CTV is capable of providing valuable information concerning the cell labeling by magnetically tagged antibodies. It was demonstrated that the magnetically conjugated antibody binding curve exhibits the same exponential increase to saturation characteristics as that seen with the fluorescently tagged antibody. Further, it was shown that the intensity of the secondary magnetic labeling is directly proportional to the intensity of the primary fluorescent label. CONCLUSIONS CTV is an accurate tool for evaluation of magnetically conjugated antibodies. The ability to determine the intensity of magnetic labeling is necessary for the development of continuous flow immunomagnetic separations based on cell magnetophoresis.
Collapse
Affiliation(s)
- Diane R Leigh
- Department of Biomedical Engineering, The Cleveland Clinic Foundation, Cleveland, OH 44195, USA
| | | | | | | | | |
Collapse
|
13
|
Higuchi A, Shindo Y, Gomei Y, Mori T, Uyama T, Umezawa A. Cell separation between mesenchymal progenitor cells through porous polymeric membranes. J Biomed Mater Res B Appl Biomater 2005; 74:511-9. [PMID: 15906389 DOI: 10.1002/jbm.b.30220] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
This study investigates the separation of two types of marrow stromal cells, KUSA-A1 osteoblasts and H-1/A preadipocytes, by filtration through various porous polymeric membranes. It was found that KUSA-A1 permeates better than H-1/A cells through 12-microm polyurethane foaming membranes. This appears to be due to the relatively smaller cell size of KUSA-A1 cells. In addition, when feed solutions containing suspensions of either cell type or a mixture of the two were used, the permeation ratio was relatively low (< 6%) through polyurethane and surface-modified polyurethane foaming membranes. It was also found that there was some degree of separation between KUSA-A1 and H-1/A cells (separation factor = 1.8) with nylon-net filter membranes, but no separation was obtained when filters made of nonwoven fabrics or silk screens were used. This ability of the nylon-net filter membranes to separate the two cell types was due to a sieving effect that results from an optimal pore size. Finally, permeation of a solution of human serum albumin through the membrane following filtration of the cells did not result in a separation of cells in the recovery solution.
Collapse
Affiliation(s)
- Akon Higuchi
- Department of Applied Chemistry, Seikei University, Musashino, Tokyo, Japan
| | | | | | | | | | | |
Collapse
|
14
|
Higuchi A, Tsukamoto Y. Cell separation of hepatocytes and fibroblasts through surface-modified polyurethane membranes. J Biomed Mater Res A 2005; 71:470-9. [PMID: 15386485 DOI: 10.1002/jbm.a.30169] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
The separation of fibroblast cells (L929 cells) and hepatocytes was investigated by using unmodified and surface-modified polyurethane (PU) foaming membranes (pore size of 12 microm) by the incorporation of various functional groups. L929 cells permeated more readily than hepatocytes, and very few populations of hepatocytes (<5%) permeated through the membranes. This result was thought to be due to the smaller cell size of the L929 cells (5-10 microm) relative to the hepatocytes (15-30 microm). The larger hepatocytes were thought to plug the pores of the membranes. A good cell separation between L929 cells and hepatocytes was achieved when the cell mixture permeated through the negatively charged PU membranes. The negatively charged membranes were thought to enhance the permeation of L929 cells because of the electrostatic repulsion between the membranes and negatively charged cells. On the other hand, the hepatocytes were unable to permeate through the membranes because of the sieve effect caused by their large cell size. The separation of hepatocytes isolated from mice at different ages was also accomplished by permeating the cell mixture through unmodified and surface-modified PU membranes.
Collapse
Affiliation(s)
- Akon Higuchi
- Department of Applied Chemistry, Seikei University, 3-3-1 Kichijoji Kitamachi, Musashino, Tokyo 180-8633, Japan.
| | | |
Collapse
|
15
|
Zhang H, Moore LR, Zborowski M, Williams PS, Margel S, Chalmers JJ. Establishment and implications of a characterization method for magnetic nanoparticle using cell tracking velocimetry and magnetic susceptibility modified solutions. Analyst 2005; 130:514-27. [PMID: 15776162 DOI: 10.1039/b412723d] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Magnetic micro and nanoparticles conjugated to affinity labels have become a significant, commercial reagent. It has been demonstrated that the performance of cell separation systems using magnetic labels is a function of the magnitude of the magnetic force that can be generated through labeling. This magnetic force is proportional to the number of magnetic particles bound to the cell, the magnetic energy gradient, and the particle-field interaction parameter. This particle-field interaction parameter, which is the product of the relative volumetric, magnetic susceptibility and the volume of the micro or nanoparticle, is a fundamental parameter which can be used to characterize the magnetic particles. An experimental technique is presented which measures the volumetric magnetic susceptibility of particles through the use of susceptibility modified solutions and an experimental instrument, Cell Tracking Velocimetry, CTV. Experimental studies were conducted on polystyrene microspheres alone and those bound to four different magnetic nanoparticles. The experimentally determined values of the magnetic susceptibility of the polystyrene microspheres are consistent with values found from literature. Consequently, magnetic susceptibility measurements of these polystyrene microspheres bound with the magnetic nanoparticles combined with particle size measurements using commercial dynamic light scattering instrument allowed estimates of the particle-field interaction parameter to be made for four commercial, magnetic nanoparticles. The value found for MACS beads is close to what is reported from an independent study. The values for MACS beads and Imag beads are found to agree with what is observed from experiments. Finally, an experimental demonstration of the impact that differences in this field interaction parameter has on the labeling of human lymphocytes is presented.
Collapse
Affiliation(s)
- Huading Zhang
- Department of Chemical and Biomolecular Engineering, The Ohio State University, 140 W 19th Ave, Columbus, OH 43210, USA
| | | | | | | | | | | |
Collapse
|
16
|
Lara O, Tong X, Zborowski M, Chalmers JJ. Enrichment of rare cancer cells through depletion of normal cells using density and flow-through, immunomagnetic cell separation. Exp Hematol 2004; 32:891-904. [PMID: 15504544 DOI: 10.1016/j.exphem.2004.07.007] [Citation(s) in RCA: 137] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2003] [Revised: 07/06/2004] [Accepted: 07/12/2004] [Indexed: 10/26/2022]
Abstract
OBJECTIVE To develop a reliable technique to enrich for rare cells in blood suspensions using only negative selection steps including a flow-through immunomagnetic cell separations system and by optimizing variables normally encountered during such enrichment processes. METHODS A human breast cancer cell line was cultivated and spiked at a ratio of 1 cancer cell to 10(5) total leukocytes in buffy coat or 1 cancer cell to 10(8) total cells in whole blood samples. The final, optimized process consisted of: a red cell lysis step, immunomagnetically staining leukocytes with an anti-CD45 PE, anti- MACS sandwich, immunomagnetic sorting using a flow-through system (QMS), and a final cell analysis step using either an automated cell counter, filtration, and visual counting or a cytospin analysis. RESULTS The final, optimized process produced a final enrichment of the rare cancer cells of 5.17 log(10) and an average, final recovery of 46%. It should be noted that a negative depletion protocol was used (i.e., no labeling of the rare cancer cells was used). CONCLUSIONS To the authors' knowledge, no examples in the literature exist of a 5.17 log(10) enrichment of cancer cells in human blood using a negative depletion protocol. The closest example is a 4 log(10) enrichment in which two positive magnetic cell separation steps were used (none were used in this study). Ongoing studies are investigating further modifications of the precommercial, prototype flow-through immunmagnetic separation system to increase both the enrichment and recovery rate. However, even at current performance levels, the presented process could significantly improve visual and molecular analysis of rare cells in blood.
Collapse
Affiliation(s)
- Oscar Lara
- Department of Chemical and Biomolecular Engineering, The Ohio State University, Columbus, Ohio, USA
| | | | | | | |
Collapse
|
17
|
Deschaseaux F, Gindraux F, Saadi R, Obert L, Chalmers D, Herve P. Direct selection of human bone marrow mesenchymal stem cells using an anti-CD49a antibody reveals their CD45med,low phenotype. Br J Haematol 2003; 122:506-17. [PMID: 12877680 DOI: 10.1046/j.1365-2141.2003.04469.x] [Citation(s) in RCA: 100] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Human bone marrow mesenchymal stem cells (MSC) generate, via a fibroblast colony-forming unit (CFU-F), osteo-chondroblastic cells as well as adipocytes and stromacytes. To date, these stem cells are isolated indirectly using a cell culture method and phenotyped as CD45 negative while the in vivo counterparts are undetermined. Our aim was to develop a direct selection method and to determine the phenotype of the MSC isolated in this way. Mesenchymal cells were selected with anti-CD49a and/or anti-CD45 antibodies using either flow cytometry or a magnetic beads method. All CFU-F were always detected in the small population of CD49a-positive cells. These CFU retained their differentiation potential and gave rise to osteo-chondroblastic cells, adipocytes and stromacytes. Phenotypic studies on uncultured cells revealed a CD45med,low, CD34low, HLA-II- cell population. Flow cytometry cell sorting showed that MSC with CFU-F potential were obtained only from a CD49a+/CD45med,low population. In addition, when cultured, they clearly became CD45-, CD34-, HLA-II-, CD49a+. These results confirmed that MSC can be directly selected easily from human bone marrow using magnetic beads without altering their differentiation potential. These cells expressed mildly the haematopoietic marker CD45, which was dramatically downregulated by in vitro culture. The expression of CD45 coupled to CD49a thus enabled direct selection of the MSC.
Collapse
|
18
|
Chosy EJ, Nakamura M, Melnik K, Comella K, Lasky LC, Zborowski M, Chalmers JJ. Characterization of antibody binding to three cancer-related antigens using flow cytometry and cell tracking velocimetry. Biotechnol Bioeng 2003; 82:340-51. [PMID: 12599261 DOI: 10.1002/bit.10581] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Proper antibody labeling is a fundamental step in the positive selection/isolation of rare cancer cells using immunomagnetic cell separation technology. Using either a two-step or single-step labeling protocol, we examined a combination of six different antibodies specific for three different antigens (epithelial specific antigen, epithelial membrane antigen, and HER-2/Neu) on two different breast cancer cell lines (HCC1954 and MCF-7). When a two-step labeling protocol was used (i.e., anti-surface marker-fluoroscein-isothiocyanate [FITC] [primary Ab], anti-FITC magnetic colloid [secondary Ab]) saturation of the primary antibody was determined using fluorescence intensity measurements from flow cytometry (FCM). The saturation of the secondary antibody (or saturation of a single-step labeling) was determined using magnetophoretic mobility measurements from cell tracking velocimetry (CTV). When the maximum magnetophoretic mobility was the primary objective, our results demonstrate that the quantities necessary for antibody saturation with respect to fluorescence intensity were generally higher than those recommended by the manufacturer. The results demonstrate that magnetophoretic mobility varies depending on the types of cell lines, primary antibodies, and concentration of secondary magnetic colloid-conjugated antibody. It is concluded that saturation studies are a vital preparatory step in any separation method involving antibody labeling, especially those that require the specificity of rare cell detection.
Collapse
Affiliation(s)
- E Julia Chosy
- Department of Chemical Engineering, Ohio State University, 125 Koffolt Laboratories, 140 West 19th Avenue, Columbus, Ohio 43210, USA
| | | | | | | | | | | | | |
Collapse
|
19
|
Higuchi A, Yamamiya SI, Yoon BO, Sakurai M, Hara M. Peripheral blood cell separation through surface-modified polyurethane membranes. ACTA ACUST UNITED AC 2003; 68:34-42. [PMID: 14661247 DOI: 10.1002/jbm.a.20005] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Cell separation from peripheral blood was investigated using surface-modified polyurethane (PU) membranes with different functional groups. Both red blood cells and platelets could pass through unmodified PU and PU-SO(3)H membranes, whereas the red blood cells preferentially passed through PU-N(C(2)H(5))(2) and PU-NHC(2)H(4)OH membranes. The permeation ratio of T and B cells was <25% for the surface-modified and unmodified PU membranes. CD34(+) cells have been recognized as various kinds of stem cells including hematopoietic and mesenchymal stem cells. The adhesiveness of CD34(+) cells on the PU membranes was found to be higher than that of red blood cells, platelets, T cells, or B cells. Overall, the adhesiveness of blood cells on the PU membranes increased in the following order: red blood cells </= platelets < T cells </= B cells < CD34(+) cells. Treatment of PU-COOH membranes with a human albumin solution to detach adhered blood cells, allowed recovery of mainly CD34(+) cells in the permeate, whereas both red blood cells and platelets could be isolated in the permeate using unmodified PU membranes. The PU membranes showed different permeation and recovery ratios of specific cells depending on the functional groups attached to the membranes.
Collapse
Affiliation(s)
- Akon Higuchi
- Department of Applied Chemistry, Seikei University, 3-1 Kichijoji Kitamachi 3, Musashino, Tokyo 180-8633, Japan.
| | | | | | | | | |
Collapse
|