1
|
Huang KH, Chen K, Morato NM, Sams TC, Dziekonski ET, Cooks RG. High-throughput microdroplet-based synthesis using automated array-to-array transfer. Chem Sci 2025; 16:7544-7550. [PMID: 40171032 PMCID: PMC11955803 DOI: 10.1039/d5sc00638d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2025] [Accepted: 03/20/2025] [Indexed: 04/03/2025] Open
Abstract
Automation of chemical synthesis and high-throughput (HT) screening are important for speeding up drug discovery. Here, we describe an automated HT picomole scale synthesis system which uses desorption electrospray ionization (DESI) to create microdroplets of reaction mixtures at individual positions from a two-dimensional reactant array and transfer them to a corresponding position in an array of collected reaction products. On-the-fly chemical transformations are facilitated by the reaction acceleration phenomenon in microdroplets and high reaction conversions are achieved during the milliseconds droplet flight time from the reactant to the product array. Successful functionalization of bioactive molecules is demonstrated through the generation of 172 analogs (64% success rate) using multiple reaction types. Synthesis throughput is ∼45 seconds/reaction including droplet formation, reaction, and collection steps, all of which occur in an integrated fashion, generating product amounts sufficient for subsequent bioactivity screening (low ng to low μg). Quantitative performance was validated using LC/MS. This system bridges the demonstrated capabilities of HT-DESI for reaction screening and label-free bioassays, allowing consolidation of the key early drug discovery steps around a single synthetic-analytical technology.
Collapse
Affiliation(s)
- Kai-Hung Huang
- Department of Chemistry, Purdue University West Lafayette Indiana 47907 USA
| | - Kitmin Chen
- Department of Chemistry, Purdue University West Lafayette Indiana 47907 USA
| | - Nicolás M Morato
- Department of Chemistry, Purdue University West Lafayette Indiana 47907 USA
- Purdue Institute for Cancer Research, Purdue University West Lafayette Indiana 47907 USA
| | - Thomas C Sams
- Department of Chemistry, Purdue University West Lafayette Indiana 47907 USA
| | - Eric T Dziekonski
- Department of Chemistry, Purdue University West Lafayette Indiana 47907 USA
| | - R Graham Cooks
- Department of Chemistry, Purdue University West Lafayette Indiana 47907 USA
- Purdue Institute for Cancer Research, Purdue University West Lafayette Indiana 47907 USA
| |
Collapse
|
2
|
Knox R, Smith R, Kempa EE, Spiess R, Schnepel C, Turner NJ, Flitsch SL, Barran PE. Direct analysis of biotransformations with mass spectrometry-DiBT-MS. Nat Protoc 2025:10.1038/s41596-025-01161-9. [PMID: 40259001 DOI: 10.1038/s41596-025-01161-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Accepted: 02/17/2025] [Indexed: 04/23/2025]
Abstract
The development and analysis of engineered enzymes is greatly assisted by the use of high-throughput screening to quickly determine the efficacy of biotransformations under various conditions. Ambient ionization, particularly desorption electrospray ionization (DESI), coupled to high-resolution mass spectrometry has the advantages of minimal requirements for sample preparation before analysis, which renders it suitable for high-throughput screening, in which the accurate mass and potentially the tandem mass spectrometry (MS) fingerprint for any given product can be used for identification. We present a protocol that permits the application of this method in routine biotechnology and chemical biology laboratories that are using engineered enzymes (such as imine reductases and carboxylic acid reductases, mentioned herein) to produce target compounds from substrates (quinoline moieties and phenyl(piperazinyl) moieties, respectively). Through the use of DESI's MS imaging capabilities, reaction monitoring can be easily visualized via imaging of selected substrate or product ions in a convenient, user-friendly workflow. We describe here how DESI-MS can be used to directly analyze the activity of biotransformations from crude cell lysate, which we term 'DiBT-MS'. The DiBT-MS method presented here is 10-1,000 times as fast as liquid chromatography-MS, with the full procedure for 96 samples taking ~2 h and consuming far less solvent and sample. Also demonstrated in this protocol is the impact of solvent spray composition on ionization efficiency of the target analyte, the benefits of a nylon membrane slide and the reusability of sample slides in multiple experiments.
Collapse
Affiliation(s)
- Ruth Knox
- Michael Barber Centre for Collaborative Mass Spectrometry, Department of Chemistry, Manchester Institute of Biotechnology, University of Manchester, Manchester, UK
| | - Rachel Smith
- Michael Barber Centre for Collaborative Mass Spectrometry, Department of Chemistry, Manchester Institute of Biotechnology, University of Manchester, Manchester, UK
| | - Emily E Kempa
- Michael Barber Centre for Collaborative Mass Spectrometry, Department of Chemistry, Manchester Institute of Biotechnology, University of Manchester, Manchester, UK
- Early Chemical Development, Pharmaceutical Sciences, R&D, AstraZeneca, Macclesfield, UK
| | - Reynard Spiess
- Michael Barber Centre for Collaborative Mass Spectrometry, Department of Chemistry, Manchester Institute of Biotechnology, University of Manchester, Manchester, UK
| | - Christian Schnepel
- Michael Barber Centre for Collaborative Mass Spectrometry, Department of Chemistry, Manchester Institute of Biotechnology, University of Manchester, Manchester, UK
- Department of Chemistry, Durham University, Durham, UK
| | - Nicholas J Turner
- Michael Barber Centre for Collaborative Mass Spectrometry, Department of Chemistry, Manchester Institute of Biotechnology, University of Manchester, Manchester, UK
| | - Sabine L Flitsch
- Michael Barber Centre for Collaborative Mass Spectrometry, Department of Chemistry, Manchester Institute of Biotechnology, University of Manchester, Manchester, UK
| | - Perdita E Barran
- Michael Barber Centre for Collaborative Mass Spectrometry, Department of Chemistry, Manchester Institute of Biotechnology, University of Manchester, Manchester, UK.
| |
Collapse
|
3
|
Liu C. Acoustic ejection mass spectrometry: the potential for personalized medicine. Expert Rev Proteomics 2025; 22:141-147. [PMID: 40205846 DOI: 10.1080/14789450.2025.2491356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2024] [Revised: 03/26/2025] [Accepted: 04/06/2025] [Indexed: 04/11/2025]
Abstract
INTRODUCTION The emergence of personalized medicine (PM) has shifted the focus of healthcare from the traditional 'one-size-fits-all' approach to strategies tailored to individual patients, accounting for genetic, environmental, and lifestyle factors. Acoustic ejection mass spectrometry (AEMS) is a novel technology that offers a robust and scalable platform for high-throughput MS readout. AEMS achieves analytical speeds of one sample per second while maintaining high data quality, broad compound coverage, and minimal sample preparation, making it an invaluable tool for PM. AREAS COVERED This article explores the potential of AEMS in critical PM applications, including therapeutic drug monitoring (TDM), proteomics, metabolomics, and mass spectrometry imaging. AEMS simplifies conventional workflows by minimizing sample preparation, enhancing automation compatibility, and enabling direct analysis of complex biological matrices. EXPERT OPINION Integrating AEMS with orthogonal separation techniques such as differential mobility spectrometry (DMS) further addresses challenges in isomer discrimination, expanding the platform's analytical capabilities. Additionally, the development of high-throughput data processing tools could further enable AEMS to accelerate the development of personalized medicine.
Collapse
|
4
|
Ghosh J, Morato NM, Feng Y, Cooks RG. High-Throughput Drug Derivatization and Bioassay by Desorption Electrospray Ionization Mass Spectrometry. Chempluschem 2025:e2500164. [PMID: 40095503 DOI: 10.1002/cplu.202500164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2025] [Accepted: 03/17/2025] [Indexed: 03/19/2025]
Abstract
Adapting high-throughput (HT) synthetic methods to the modification of drugs and to testing of their bioactivity should expedite drug discovery. Herein, the applicability of HT desorption electrospray ionization mass spectrometry (DESI MS) to achieve late-stage functionalization (LSF) and rapidly generate a modified opioid library is demonstrated. Specifically, aza-Michael addition and sulfur (VI) fluoride exchange reactions are used for functionalization. The modified drugs are both synthesized and characterized using an automated HT-DESI MS platform, with the reaction occurring during the droplet flight. Analysis by MS characterizes reaction products at a throughput of >1 reaction per second. With this platform, multiple nor-opioid scaffolds and functionalization reagents are screened and a selection of the hits obtained is subjected to HT label-free bioassays using the same DESI-MS platform. This combination of accelerated LSF reactions to rapidly create a diverse library of functionalized drugs with direct bioassays of the crude reaction mixtures for structure-activity relationship evaluation, both using the same platform, is anticipated to help expedite the early drug discovery process.
Collapse
Affiliation(s)
- Jyotirmoy Ghosh
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907, USA
| | - Nicolás M Morato
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907, USA
| | - Yunfei Feng
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907, USA
| | - R Graham Cooks
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907, USA
| |
Collapse
|
5
|
Huang KH, Morato N, Feng Y, Toney A, Cooks RG. Rapid Exploration of Chemical Space by High-Throughput Desorption Electrospray Ionization Mass Spectrometry. J Am Chem Soc 2024; 146:33112-33120. [PMID: 39561979 PMCID: PMC11622223 DOI: 10.1021/jacs.4c11037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2024] [Revised: 10/28/2024] [Accepted: 10/29/2024] [Indexed: 11/21/2024]
Abstract
This study leverages accelerated reactions at the solution/air interface of microdroplets generated by desorption electrospray ionization (DESI) to explore the chemical space. DESI is utilized to synthesize drug analogs at an overall rate of 1 reaction mixture per second, working on the low-nanogram scale. Transformations of multiple drug molecules at specific functionalities (phenol, hydroxyl, amino, carbonyl, phenyl, thiophenyl, and alkenyl) are achieved using electrophilic/nucleophilic, redox, C-H functionalization, and coupling reactions. These transformations occur under ambient conditions on the millisecond time scale with direct detection of products being successful in all but three of the reaction types studied. The large scope (22 bioactive compounds, >20 chemical transformations, and >300 functionalization reagents) and high speed (>3000 reactions/hour) provide access to a wide array of drug analogs that can be used for bioactivity testing. A total of ∼6800 unique reactions were examined through a data-driven workflow, and more than 3000 unique derivatives (∼44%) were identified tentatively by the m/z value and signal-to-control ratio in single-stage mass spectrometry (MS) analysis, with over 1000 being further characterized by tandem MS. The speed of the DESI-MS reaction screen provides potential advantages for emerging machine learning-based predictions of organic synthesis, and it sets the stage for future online DESI-MS bioassays and scaled-up microdroplet synthesis before formal characterization of hit compounds is sought using traditional methods of drug discovery.
Collapse
Affiliation(s)
- Kai-Hung Huang
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Nicolás
M. Morato
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Yunfei Feng
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Alexis Toney
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - R. Graham Cooks
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
6
|
Ji H, Yin X, Ang WE, Rawshan AB, Gay S, Ma J, Aw CC, Liu C. Automatic cleaning in acoustic ejection mass spectrometry: Enhancing the system robustness for large-scale high-throughput analysis of complex samples. SLAS Technol 2024; 29:100227. [PMID: 39581265 DOI: 10.1016/j.slast.2024.100227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2024] [Revised: 11/12/2024] [Accepted: 11/22/2024] [Indexed: 11/26/2024]
Abstract
The rapid evolution of high-throughput mass spectrometry (HT-MS) technologies has positioned MS as a pivotal analytical tool across diverse disciplines. Its significance is particularly pronounced in high-throughput drug discovery and development, where MS plays a critical role throughout various phases. Acoustic ejection mass spectrometry (AEMS) is a recent addition to the HT-MS landscape, showcasing a balanced performance high analytical throughput and high data quality. Particularly, AEMS's in-line dilution feature allows the direct analysis of large-scale, complex reaction solutions without the need for sample cleanup, making it a popular choice for large-scale high-throughput screenings. However, the substantial volume of complex matrix introduces concerns about system robustness, specifically regarding the potential clogging of the sample transfer line. This study addresses this challenge by introducing an integrated automatic washing feature to the AEMS system. This enhancement significantly improves system robustness without imposing any additional demands on assay execution time. Demonstrating an extended electrode lifetime, the cleaning approach proves effective in maintaining system performance over prolonged periods, showcasing its potential for continuous large-sample-scale high-throughput analysis applications.
Collapse
Affiliation(s)
| | | | | | | | | | - Jing Ma
- SCIEX, Singapore 739256, Singapore
| | | | - Chang Liu
- SCIEX, Concord, Ontario L4K 4V8, Canada.
| |
Collapse
|
7
|
Hoxie N, Calabrese DR, Itkin Z, Gomba G, Shen M, Verma M, Janiszewski JS, Shrimp JH, Wilson KM, Michael S, Hall MD, Burton L, Covey T, Liu C. High-resolution acoustic ejection mass spectrometry for high-throughput library screening. SLAS Technol 2024; 29:100199. [PMID: 39427991 DOI: 10.1016/j.slast.2024.100199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Revised: 09/09/2024] [Accepted: 10/10/2024] [Indexed: 10/22/2024]
Abstract
An approach is described for high-throughput quality assessment of drug candidate libraries using high-resolution acoustic ejection mass spectrometry (AEMS). Sample introduction from 1536-well plates is demonstrated for this application using 2.5 nL acoustically dispensed sample droplets into an Open Port Interface (OPI) with pneumatically assisted electrospray ionization at a rate of one second per sample. Both positive and negative ionization are shown to be essential to extend the compound coverage of this protease inhibitor-focused library. Specialized software for efficiently interpreting this data in 1536-well format is presented. A new high-throughput method for quantifying the concentration of the components (HTQuant) is proposed that neither requires adding an internal standard to each well nor further encumbers the high-throughput workflow. This approach for quantitation requires highly reproducible peak areas, which is shown to be consistent within 4.4 % CV for a 1536-well plate analysis. An approach for troubleshooting the workflow based on the background ion current signal is also presented. The AEMS data is compared to the industry standard LC/PDA/ELSD/MS approach and shows similar coverage but at 180-fold greater throughput. Despite the same ionization process, both methods confirmed the presence of a small percentage of compounds in wells that the other did not. The data for this relatively small, focused library is compared to a larger, more chemically diverse library to indicate that this approach can be more generally applied beyond this single case study. This capability is particularly timely considering the growing implementation of artificial intelligence strategies that require the input of large amounts of high-quality data to formulate predictions relevant to the drug discovery process. The molecular structures of the 872-compound library analyzed here are included to begin the process of correlating molecular structures with ionization efficiency and other parameters as an initial step in this direction.
Collapse
Affiliation(s)
- Nate Hoxie
- NIH/NCATS National Institutes of Health/ National Center for the Advancing Translational Sciences, Rockville, MD, USA.
| | - David R Calabrese
- NIH/NCATS National Institutes of Health/ National Center for the Advancing Translational Sciences, Rockville, MD, USA
| | - Zina Itkin
- NIH/NCATS National Institutes of Health/ National Center for the Advancing Translational Sciences, Rockville, MD, USA
| | - Glenn Gomba
- NIH/NCATS National Institutes of Health/ National Center for the Advancing Translational Sciences, Rockville, MD, USA
| | - Min Shen
- NIH/NCATS National Institutes of Health/ National Center for the Advancing Translational Sciences, Rockville, MD, USA
| | - Meghav Verma
- NIH/NCATS National Institutes of Health/ National Center for the Advancing Translational Sciences, Rockville, MD, USA
| | - John S Janiszewski
- NIH/NCATS National Institutes of Health/ National Center for the Advancing Translational Sciences, Rockville, MD, USA
| | - Jonathan H Shrimp
- NIH/NCATS National Institutes of Health/ National Center for the Advancing Translational Sciences, Rockville, MD, USA
| | - Kelli M Wilson
- NIH/NCATS National Institutes of Health/ National Center for the Advancing Translational Sciences, Rockville, MD, USA
| | - Sam Michael
- NIH/NCATS National Institutes of Health/ National Center for the Advancing Translational Sciences, Rockville, MD, USA
| | - Matthew D Hall
- NIH/NCATS National Institutes of Health/ National Center for the Advancing Translational Sciences, Rockville, MD, USA
| | | | | | | |
Collapse
|
8
|
Li J, Morato NM, Westover LS, Abeywickrema P, Geng J, Piassek M, Harden D, Strambeanu I, Shi Z, Cooks RG, Meng J. High-Throughput Assessment of Bile Salt Export Pump Inhibition Using RapidFire-MS and DESI-MS. ACS Med Chem Lett 2024; 15:1584-1590. [PMID: 39291028 PMCID: PMC11403724 DOI: 10.1021/acsmedchemlett.4c00302] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2024] [Revised: 08/01/2024] [Accepted: 08/08/2024] [Indexed: 09/19/2024] Open
Abstract
The bile salt export pump (BSEP) assay is widely used to evaluate the potential for drug-induced liver injury (DILI) early in the drug discovery process. While traditional liquid chromatography-mass spectrometry (LC-MS)-based approaches have been utilized for BSEP activity testing, they have intrinsic limitations in either throughput or the requirement for sample preparation and are difficult to scale up in order to screen drug candidates. Here we demonstrate the use of two different high-throughput MS methods based on solid-phase extraction (SPE) and desorption electrospray ionization (DESI) for high-throughput BSEP activity assessment in a label-free manner, with minimal needs for sample workup, at sampling rates of ∼11 and ∼5.5 s/sample, respectively. Both approaches were validated, compared, and successfully applied to the evaluation of 96 drug candidates for the inhibition of taurocholic acid (TCA) transport using BSEP vesicles.
Collapse
Affiliation(s)
- Jie Li
- Global Discovery Chemistry, Janssen Research and Development, Spring House, Pennsylvania 19477, United States
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Nicolás M Morato
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Lori S Westover
- Discovery Technology and Molecular Pharmacology, Janssen Research and Development, Spring House, Pennsylvania 19477, United States
| | - Pravien Abeywickrema
- Discovery Technology and Molecular Pharmacology, Janssen Research and Development, Spring House, Pennsylvania 19477, United States
| | - Jieping Geng
- Discovery Technology and Molecular Pharmacology, Janssen Research and Development, Spring House, Pennsylvania 19477, United States
| | - Madison Piassek
- Discovery Technology and Molecular Pharmacology, Janssen Research and Development, Spring House, Pennsylvania 19477, United States
| | - David Harden
- Discovery Technology and Molecular Pharmacology, Janssen Research and Development, Spring House, Pennsylvania 19477, United States
| | - Iulia Strambeanu
- Global Discovery Chemistry, Janssen Research and Development, Spring House, Pennsylvania 19477, United States
| | - Zhicai Shi
- Global Discovery Chemistry, Janssen Research and Development, Spring House, Pennsylvania 19477, United States
| | - R Graham Cooks
- Department of Chemistry, Purdue University, West Lafayette, Indiana 47907, United States
| | - Juncai Meng
- Discovery Technology and Molecular Pharmacology, Janssen Research and Development, Spring House, Pennsylvania 19477, United States
| |
Collapse
|
9
|
Cox DM, Yin X, Alam J, Georgescu B, Latawiec A, Tan R, Aw CC, Harradine P, Liu C. Sample-Specific MS/MS Methods in High-Throughput Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:2230-2236. [PMID: 39092830 DOI: 10.1021/jasms.4c00278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/04/2024]
Abstract
The drug discovery process increasingly relies on high-throughput sample analysis to accelerate the identification of viable drug candidates. Recently, chromatographic-free high-throughput mass spectrometry (HT-MS) technologies have emerged, significantly increasing sample readout speed and enabling the analysis of large sample sets. These HT-MS platforms continuously acquire data from various samples into a single data file, presenting challenges in applying distinctive data acquisition methods to specific samples. This study introduces a novel approach that integrates real-time sample loading status to activate sample-specific MS/MS data acquisition methods on the high-throughput acoustic ejection mass spectrometry platform. Effective method switching and high signal reproducibility were demonstrated across different data acquisition window durations in multiple reaction monitoring (MRM), high-resolution MRM (MRMHR), and information-dependent acquisition modes. This advancement provides a user-friendly and robust solution to the method-setting challenges of HT-MS, expanding the implementation of HT-MS platforms in drug discovery and other high-throughput analytical applications.
Collapse
Affiliation(s)
| | | | - Jahangir Alam
- Pharmacokinetics, Dynamics, Metabolism & Bioanalytics, Merck & Co., Inc., West Point, Pennsylvania 19486, United States
| | | | | | - Rudy Tan
- SCIEX, Singapore, 739256 Singapore
| | | | - Paul Harradine
- Pharmacokinetics, Dynamics, Metabolism & Bioanalytics, Merck & Co., Inc., West Point, Pennsylvania 19486, United States
| | - Chang Liu
- SCIEX, Concord, Ontario L4K 4V8, Canada
| |
Collapse
|
10
|
Shanley J, Pu F, Williams JD, Elsen NL, Gopalakrishnan SM, Pan JY, Radosevich AJ. Collaborative robotics to enable ultra-high-throughput IR-MALDESI. SLAS Technol 2024; 29:100163. [PMID: 39047813 DOI: 10.1016/j.slast.2024.100163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 06/26/2024] [Accepted: 07/18/2024] [Indexed: 07/27/2024]
Abstract
Over the last 5 years, IR-MALDESI-MS (Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry) has been demonstrated for use in a range of high-throughput biochemical and cellular assays with remarkable sample acquisition rates up to 22 Hz for a single 384-well assay plate. With such high single plate acquisition rates, the rate limiting step becomes how fast subsequent plates can be presented to the MS for analysis. To make this transfer as fast as possible while maintaining safe operation in a laboratory environment, we developed a collaborative robotic plate transfer system (CRPTS) that combines a 6-axis robot with dual plate grippers, a 7th axis conveyor stage, and a 420-plate capacity sample loading window. As a demonstration of the throughput and flexibility of CRPTS, we performed a biochemical assay that monitored the oxidation of tris(2-carboxyethyl)phosphine (TCEP) to screen for nuisance compounds. Using continuous and step motion scan profiles, we analyzed 158,799 compounds contained in 448 assay plates over the course of 12.5 h (Z-Factor=0.87) and 17.5 h (Z-factor=0.99), respectively. Extrapolating these results enables the screening of a million compounds within 6-7 working days.
Collapse
Affiliation(s)
- John Shanley
- AbbVie Inc., 1 North Waukegan Rd., North Chicago, IL 60064.
| | - Fan Pu
- AbbVie Inc., 1 North Waukegan Rd., North Chicago, IL 60064
| | - Jon D Williams
- AbbVie Inc., 1 North Waukegan Rd., North Chicago, IL 60064
| | | | | | - Jeffrey Y Pan
- AbbVie Inc., 1 North Waukegan Rd., North Chicago, IL 60064
| | | |
Collapse
|
11
|
Feng Y, Morato NM, Huang KH, Lin M, Cooks RG. High-throughput label-free opioid receptor binding assays using an automated desorption electrospray ionization mass spectrometry platform. Chem Commun (Camb) 2024; 60:8224-8227. [PMID: 39007214 PMCID: PMC11293027 DOI: 10.1039/d4cc02346c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2024] [Accepted: 07/09/2024] [Indexed: 07/16/2024]
Abstract
The current opioid epidemic has incentivized the discovery of new non-addictive analgesics, a process that requires the screening of opioid receptor binding, traditionally performed using radiometric assays. Here we describe a label-free alternative based on high-throughput (1 Hz) ambient mass spectrometry for screening the receptor binding of new opioid analogues.
Collapse
Affiliation(s)
- Yunfei Feng
- Department of Chemistry, Bindley Bioscience Center, and Purdue Institute for Cancer Research, Purdue University, West Lafayette, IN 47907, USA.
| | - Nicolás M Morato
- Department of Chemistry, Bindley Bioscience Center, and Purdue Institute for Cancer Research, Purdue University, West Lafayette, IN 47907, USA.
| | - Kai-Hung Huang
- Department of Chemistry, Bindley Bioscience Center, and Purdue Institute for Cancer Research, Purdue University, West Lafayette, IN 47907, USA.
| | - Mina Lin
- Department of Chemistry, Bindley Bioscience Center, and Purdue Institute for Cancer Research, Purdue University, West Lafayette, IN 47907, USA.
| | - R Graham Cooks
- Department of Chemistry, Bindley Bioscience Center, and Purdue Institute for Cancer Research, Purdue University, West Lafayette, IN 47907, USA.
| |
Collapse
|
12
|
Liu C, Zhang H. Data processing for high-throughput mass spectrometry in drug discovery. Expert Opin Drug Discov 2024; 19:815-825. [PMID: 38785418 DOI: 10.1080/17460441.2024.2354871] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2024] [Accepted: 05/08/2024] [Indexed: 05/25/2024]
Abstract
INTRODUCTION High-throughput mass spectrometry that could deliver > 10 times faster sample readout speed than traditional LC-based platforms has emerged as a powerful analytical technique, enabling the rapid analysis of complex biological samples. This increased speed of MS data acquisition has brought a critical demand for automatic data processing capabilities that should match or surpass the speed of data acquisition. Those data processing capabilities should serve the different requirements of drug discovery workflows. AREAS COVERED This paper introduced the key steps of the automatic data processing workflows for high-throughput MS technologies. Specific examples and requirements are detailed for different drug discovery applications. EXPERT OPINION The demand for automatic data processing in high-throughput mass spectrometry is driven by the need to keep pace with the accelerated speed of data acquisition. The seamless integration of processing capabilities with LIMS, efficient data review mechanisms, and the exploration of future features such as real-time feedback, automatic method optimization, and AI model training is crucial for advancing the drug discovery field. As technology continues to evolve, the synergy between high-throughput mass spectrometry and intelligent data processing will undoubtedly play a pivotal role in shaping the future of high-throughput drug discovery applications.
Collapse
Affiliation(s)
| | - Hui Zhang
- Iambic Therapeutics, San Diego, CA, USA
| |
Collapse
|
13
|
Quinn A, Ivosev G, Chin J, Mongillo R, Veiga C, Covey TR, Kapinos B, Khunte B, Zhang H, Troutman MD, Liu C. High-Throughput Compound Quality Assessment with High-Mass-Resolution Acoustic Ejection Mass Spectrometry: An Automatic Data Processing Toolkit. Anal Chem 2024; 96:8381-8389. [PMID: 38750648 DOI: 10.1021/acs.analchem.3c05435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
Pharmacological screening heavily relies on the reliability of compound libraries. To ensure the accuracy of screening results, fast and reliable quality control (QC) of these libraries is essential. While liquid chromatography (LC) with ultraviolet (UV) or mass spectrometry (MS) detection has been employed for molecule QC on small sample sets, the analytical throughput becomes a bottleneck when dealing with large libraries. Acoustic ejection mass spectrometry (AEMS) is a high-throughput analytical platform that covers a broad range of chemical structural space. In this study, we present the utilization of an AEMS system equipped with a high-resolution MS analyzer for high-throughput compound QC. To facilitate efficient data processing, which is a key challenge for such a high-throughput application, we introduce an automatic data processing toolkit that allows for the high-throughput assessment of the sample standards' quantitative and qualitative characteristics, including purity calculation with the background processing option. Moreover, the toolkit includes a module for quantitatively comparing spectral similarity with the reference library. Integrating the described high-resolution AEMS system with the data processing toolkit effectively eliminates the analytical bottleneck, enabling a rapid and reliable compound quality assessment of large-scale compound libraries.
Collapse
Affiliation(s)
- Alandra Quinn
- Pfizer Global Research and Development, Groton, Connecticut 06340, United States
| | - Gordana Ivosev
- SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada
| | - Jefferson Chin
- Pfizer Global Research and Development, Groton, Connecticut 06340, United States
- AssayQuant Technologies, Marlborough, Massachusetts 01752, United States
| | - Robert Mongillo
- Pfizer Global Research and Development, Groton, Connecticut 06340, United States
| | - Cristiano Veiga
- SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada
- Red Hat, Toronto, Ontario M5C 3G8, Canada
| | - Thomas R Covey
- SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada
| | - Brendon Kapinos
- Pfizer Global Research and Development, Groton, Connecticut 06340, United States
| | - Bhagyashree Khunte
- Pfizer Global Research and Development, Groton, Connecticut 06340, United States
| | - Hui Zhang
- Pfizer Global Research and Development, Groton, Connecticut 06340, United States
- Iambic Therapeutics, San Diego, California 92121, United States
| | - Matthew D Troutman
- Pfizer Global Research and Development, Groton, Connecticut 06340, United States
| | - Chang Liu
- SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4V8, Canada
| |
Collapse
|
14
|
Ma J, Aw CC, Ji H, Lin S, Yin X, Tey H, Liu C. High-Throughput Acoustic Ejection Mass Spectrometry with Adjustable Signal Durations. Anal Chem 2024; 96:5357-5362. [PMID: 38554076 DOI: 10.1021/acs.analchem.3c05167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/01/2024]
Abstract
High-throughput mass spectrometry (MS) has witnessed rapid advancements and has found extensive applications across various disciplines. It enables the fast and accurate analysis of large sample sets, delivering a 10-fold or greater enhancement in analytical throughput when compared to conventional LC-MS methods. However, the signal duration in these high-throughput MS technologies is typically confined to a narrow range, presenting challenges for workflows demanding prolonged signal durations. In this study, we introduce a method that enables precise modulation of the signal duration on an acoustic ejection mass spectrometry (AEMS) system while ensuring high signal reproducibility. This flexibility allows for simultaneous and precise analysis of a significantly greater number of MS/MS transitions in high-throughput MS environments. Additionally, it offers a unique approach for parameter optimization and method development with minimal sample volume requirements. This advancement enhances the efficiency of MS-based analyses across diverse applications and facilitates broader utilization of MS technologies in high-throughput settings, including data-dependent acquisition (DDA) and data-independent acquisition (DIA).
Collapse
Affiliation(s)
- Jing Ma
- SCIEX, Singapore 739256, Singapore
| | | | | | | | | | | | - Chang Liu
- SCIEX, Concord, Ontario L4K 4V8, Canada
| |
Collapse
|
15
|
Williams JD, Pu F, Sawicki JW, Elsen NL. Ultra-high-throughput mass spectrometry in drug discovery: fundamentals and recent advances. Expert Opin Drug Discov 2024; 19:291-301. [PMID: 38111363 DOI: 10.1080/17460441.2023.2293153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2023] [Accepted: 12/06/2023] [Indexed: 12/20/2023]
Abstract
INTRODUCTION Ultra-high-throughput mass spectrometry, uHT-MS, is a technology that utilizes ionization and sample delivery technologies optimized to enable sampling from well plates at > 1 sample per second. These technologies do not need a chromatographic separation step and can be utilized in a wide variety of assays to detect a broad range of analytes including small molecules, lipids, and proteins. AREAS COVERED This manuscript provides a brief historical review of high-throughput mass spectrometry and the recently developed technologies that have enabled uHT-MS. The report also provides examples and references on how uHT-MS has been used in biochemical and chemical assays, nuisance compound profiling, protein analysis and high throughput experimentation for chemical synthesis. EXPERT OPINION The fast analysis time provided by uHT-MS is transforming how biochemical and chemical assays are performed in drug discovery. The potential to associate phenotypic responses produced by 1000's of compound treatments with changes in endogenous metabolite and lipid signals is becoming feasible. With the augmentation of simple, fast, high-throughput sample preparation, the scope of uHT-MS usage will increase. However, it likely will not supplant LC-MS for analyses that require low detection limits from complex matrices or characterization of complex biotherapeutics such as antibody-drug conjugates.
Collapse
Affiliation(s)
| | - Fan Pu
- Abbvie Discovery Research, North Chicago, IL, USA
| | | | | |
Collapse
|
16
|
Zheng B, Wu Y, Xue L, Sun J, Liu J, Cheng H. Is Reaction Acceleration of Microdroplet Chemistry Favorable to Controlling the Enantioselectivity? J Org Chem 2023; 88:16186-16195. [PMID: 37948325 DOI: 10.1021/acs.joc.3c01660] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2023]
Abstract
Microdroplet chemistry has been proven to amazingly accelerate many chemical and biological reactions in the past 2 decades. Current microdroplet accelerated reactions are predominantly symmetric synthetic but minorly asymmetric synthetic reactions, where stereoselectivity is scarcely concerned. This study selected unimolecular and bimolecular reactions, multicomponent Passerini reactions, and enzymatic ketone reduction as the model reactions to illustrate whether reaction acceleration of microdroplet chemistry is favorable to retaining a chiral center and controlling the enantioselectivity or not. The results illustrated that microdroplet chemistry did not disrupt pre-existing stereogenic centers in chiral starting materials during reactions but did harm to stereospecificity in asymmetric catalysis by chiral catalysts and chiral organic ligands with the exclusion of enzymatic reactions. Our preliminary study reminds us of more cautions to the product enantioselectivity when conducting asymmetric catalysis in microdroplets. We also hope this study may promote more valuable further research on the stereoselectivity of microdroplet chemistry.
Collapse
Affiliation(s)
- Boyu Zheng
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China
| | - Yikang Wu
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China
| | - Luyun Xue
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China
| | - Jiannan Sun
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China
| | - Jinhua Liu
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China
| | - Heyong Cheng
- College of Material, Chemistry and Chemical Engineering, Key Laboratory of Organosilicon Chemistry and Material Technology, Ministry of Education, Hangzhou Normal University, 2318 Yuhangtang Road, Hangzhou 311121, China
| |
Collapse
|
17
|
Abstract
Mass spectrometry (MS) is one of the most widely used technologies in the chemical sciences. With applications spanning the monitoring of reaction products, the identification of disease biomarkers, and the measurement of thermodynamic parameters and aspects of structural biology, MS is well established as a universal analytical tool applicable to small compounds as well as large molecular complexes. Regardless of the application, the generation of gas-phase ions from neutral compounds is a key step in any MS experiment. However, this ionization step was for many years limited to high-energy approaches that required gas-phase analytes and thus it was restricted to volatile samples. Over the last few decades, new methodologies have been developed to address this limitation and facilitate ionization of biological molecules. Electrospray ionization (ESI) is the most broadly used of these methods, as it facilitates the ionization of intact polar compounds from solution. Twenty years ago, our group reported a new ionization method that uses a charged solvent spray to impact a surface, generating ions from objects rather than just solutions and doing so directly in the ambient environment with no vacuum requirements and little to no sample preparation. This method was termed desorption electrospray ionization (DESI), and it initiated a new field that would come to be known as ambient mass spectrometry. The simplicity and wide applicability of the DESI technology—and the tens of ambient ionization methods developed subsequently—revolutionized the MS analysis of complex materials for their organic components, especially for in situ applications. This Account describes the history of DESI, starting with the development of the technique from early electrosonic spray ionization (ESSI) experimental observations as well as the studies leading to the understanding of its mechanism as a “droplet pick-up” phenomenon involving sequential events (i.e. , thin film formation, solid–liquid extraction, secondary droplet generation, and ESI-like ionization from these droplets). We also overview the developments and applications of the technology that have been demonstrated by our group during the last two decades. In particular, we describe (i) the use of DESI for tissue imaging, one of its more significant applications to date, and its extension to intraoperative clinical diagnosis; (ii) the integration of the technology with portable instrumentation for in situ analysis, especially when coupled with tandem mass spectrometry (MS/MS); (iii) the use of DESI microdroplets as microvessels to accelerate organic reactions by orders of magnitude compared to those in bulk solution; and (iv) the combination of all these capabilities for automated high-throughput experiments aimed at accelerating drug discovery.
Collapse
Affiliation(s)
- Nicolás M Morato
- Department of Chemistry and Bindley Bioscience Center, Purdue University, West Lafayette, Indiana 47907, United States
| | - R Graham Cooks
- Department of Chemistry and Bindley Bioscience Center, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
18
|
Goudarzi CC, Woolfork AG, Sengupta A, Weljie AM. Customized Surface Design to Increase Throughput of Ambient Ionization Mass Spectrometry Lipidomics. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:1970-1978. [PMID: 37540625 DOI: 10.1021/jasms.3c00062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/06/2023]
Abstract
Increased access to cheap and rapid mass spectrometry testing of biofluids is desirable for the analysis of disorders and diseases that may be linked to alterations in metabolite or lipid levels. The objective of this study is to establish an easily customized high-throughput workflow for the analysis of biological samples using desorption electrospray ionization-mass spectrometry (DESI-MS). The guiding principles of this workflow are the use of low-cost, open-source, and readily accessible materials with high-throughput and reproducibility. The design consists of 3 steps: (1) PARAFILM surface customization of size, shape, and depth of features on PARAFILM via 3D printed molds; (2) sample spotting via high-throughput robotics using the relatively inexpensive and open-source Opentrons platform to reduce variability and increase reliability of sample spotting; and (3) an open-source point-and-click graphical user interface (MSI.EAGLE) for data analysis via the R statistical language building on the Cardinal package. Here we describe this workflow and test optimal surface ionization characteristics by comparison of serum extracts spotted on PARAFILM and on PTFE (porous and nonporous). Untargeted analysis across three surfaces suggests that they are all suitable for ionization of a wide range of metabolites and lipids, with 3983 m/z features detected. Differential analysis of polar vs nonpolar serum extracts suggests that ∼80% of ions are desorbed preferentially from different surfaces. PARAFILM is less impacted by the interference of background ions derived from the surface. The developed system allows for a wide range of researchers to access custom surface design workflows and high-throughput analyses in a highly cost-effective manner.
Collapse
|
19
|
Cooks RG, Feng Y, Huang KH, Morato NM, Qiu L. Re-Imagining Drug Discovery using Mass Spectrometry. Isr J Chem 2023; 63:e202300034. [PMID: 37829547 PMCID: PMC10569432 DOI: 10.1002/ijch.202300034] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Indexed: 03/22/2023]
Abstract
It is argued that each of the three key steps in drug discovery, (i) reaction screening to find successful routes to desired drug candidates, (ii) scale up of the synthesis to produce amounts adequate for testing, and (iii) bioactivity assessment of the candidate compounds, can all be performed using mass spectrometry (MS) in a sequential fashion. The particular ionization method of choice, desorption electrospray ionization (DESI), is both an analytical technique and a procedure for small-scale synthesis. It is also highly compatible with automation, providing for high throughput in both synthesis and analysis. Moreover, because accelerated reactions take place in the secondary DESI microdroplets generated from individual reaction mixtures, this allows either online analysis by MS or collection of the synthetic products by droplet deposition. DESI also has the unique advantage, amongst spray-based MS ionization methods, that complex buffered biological solutions can be analyzed directly, without concern for capillary blockage. Here, all these capabilities are illustrated, the unique chemistry at droplet interfaces is presented, and the possible future implementation of DESI-MS based drug discovery is discussed.
Collapse
Affiliation(s)
- R Graham Cooks
- Department of Chemistry and Bindley Bioscience Center, Purdue University, West Lafayette, IN 47907 USA
| | - Yunfei Feng
- Department of Chemistry and Bindley Bioscience Center, Purdue University, West Lafayette, IN 47907 USA
| | - Kai-Hung Huang
- Department of Chemistry and Bindley Bioscience Center, Purdue University, West Lafayette, IN 47907 USA
| | - Nicolás M Morato
- Department of Chemistry and Bindley Bioscience Center, Purdue University, West Lafayette, IN 47907 USA
| | - Lingqi Qiu
- Department of Chemistry and Bindley Bioscience Center, Purdue University, West Lafayette, IN 47907 USA
| |
Collapse
|
20
|
Talaty NN, Johnson RW, Sawicki J, Nacham O, Djuric SW. Recent Developments in Mass Spectrometry to Support Next-Generation Synthesis and Screening. ACS Med Chem Lett 2023; 14:711-718. [PMID: 37312853 PMCID: PMC10258828 DOI: 10.1021/acsmedchemlett.3c00040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 05/10/2023] [Indexed: 06/15/2023] Open
Abstract
The complexity of new therapeutics continues to increase and the timeline for the discovery of these therapeutics continues to shrink. This creates demand for new analytical techniques to facilitate quicker discovery and development of novel drugs. Mass spectrometry is one of the most prolific analytical techniques that has been applied across the entire drug discovery pipeline. New mass spectrometers and the associated methods for sampling have been introduced at a rate that keeps pace with new chemistries, therapeutic types, and screening practices used by modern drug hunters. This microperspective covers application and implementation of new mass spectrometry workflows that enable current and future efforts in screening and synthesis for drug discovery.
Collapse
Affiliation(s)
- Nari N. Talaty
- Discovery
Platform Technologies, AbbVie Inc., North Chicago, Illinois 60064, United States
| | - Robert W. Johnson
- Discovery
Platform Technologies, AbbVie Inc., North Chicago, Illinois 60064, United States
| | - James Sawicki
- Discovery
Platform Technologies, AbbVie Inc., North Chicago, Illinois 60064, United States
| | - Omprakash Nacham
- Discovery
Platform Technologies, AbbVie Inc., North Chicago, Illinois 60064, United States
| | - Stevan W. Djuric
- Discovery
Chemistry and Technology Consulting LLC, New Bern, North Carolina 28562, United States
| |
Collapse
|
21
|
Huang KH, Morato NM, Feng Y, Cooks RG. High-Throughput Diversification of Complex Bioactive Molecules by Accelerated Synthesis in Microdroplets. Angew Chem Int Ed Engl 2023; 62:e202300956. [PMID: 36941213 PMCID: PMC10182919 DOI: 10.1002/anie.202300956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 03/17/2023] [Accepted: 03/20/2023] [Indexed: 03/23/2023]
Abstract
Late-stage diversification of drug molecules is an important strategy in drug discovery that can be facilitated by reaction screening using high-throughput experimentation. Here we present a rapid method for functionalizing bioactive molecules based on accelerated reactions in microdroplets. Reaction mixtures are nebulized at throughputs better than 1 reaction/second and the accelerated reactions occurring in the microdroplets are followed by desorption electrospray ionization mass spectrometry (DESI-MS). Because the accelerated reactions occur on the millisecond timescale, they allow an overall screening throughput of 1 Hz working at the low nanogram scale. Using this approach, an opioid agonist (PZM21) and an antagonist (naloxone) were diversified using three reactions important in medicinal chemistry: sulfur fluoride exchange (SuFEx) click reactions, imine formation reactions, and ene-type click reactions. Some 269 functionalized analogs of naloxone and PZM21 were generated and characterized by tandem mass spectrometry (MS/MS) after screening over 500 reactions.
Collapse
Affiliation(s)
- Kai-Hung Huang
- Department of Chemistry, Purdue University, West Lafayette, IN, USA
| | - Nicolás M Morato
- Department of Chemistry, Purdue University, West Lafayette, IN, USA
| | - Yunfei Feng
- Department of Chemistry, Purdue University, West Lafayette, IN, USA
| | - R Graham Cooks
- Department of Chemistry, Purdue University, West Lafayette, IN, USA
| |
Collapse
|
22
|
Vasina M, Kovar D, Damborsky J, Ding Y, Yang T, deMello A, Mazurenko S, Stavrakis S, Prokop Z. In-depth analysis of biocatalysts by microfluidics: An emerging source of data for machine learning. Biotechnol Adv 2023; 66:108171. [PMID: 37150331 DOI: 10.1016/j.biotechadv.2023.108171] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 05/04/2023] [Accepted: 05/04/2023] [Indexed: 05/09/2023]
Abstract
Nowadays, the vastly increasing demand for novel biotechnological products is supported by the continuous development of biocatalytic applications which provide sustainable green alternatives to chemical processes. The success of a biocatalytic application is critically dependent on how quickly we can identify and characterize enzyme variants fitting the conditions of industrial processes. While miniaturization and parallelization have dramatically increased the throughput of next-generation sequencing systems, the subsequent characterization of the obtained candidates is still a limiting process in identifying the desired biocatalysts. Only a few commercial microfluidic systems for enzyme analysis are currently available, and the transformation of numerous published prototypes into commercial platforms is still to be streamlined. This review presents the state-of-the-art, recent trends, and perspectives in applying microfluidic tools in the functional and structural analysis of biocatalysts. We discuss the advantages and disadvantages of available technologies, their reproducibility and robustness, and readiness for routine laboratory use. We also highlight the unexplored potential of microfluidics to leverage the power of machine learning for biocatalyst development.
Collapse
Affiliation(s)
- Michal Vasina
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic
| | - David Kovar
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic
| | - Jiri Damborsky
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic
| | - Yun Ding
- Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland
| | - Tianjin Yang
- Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland; Department of Biochemistry, University of Zurich, 8057 Zurich, Switzerland
| | - Andrew deMello
- Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland
| | - Stanislav Mazurenko
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic.
| | - Stavros Stavrakis
- Institute for Chemical and Bioengineering, ETH Zürich, 8093 Zürich, Switzerland.
| | - Zbynek Prokop
- Loschmidt Laboratories, Department of Experimental Biology and RECETOX, Faculty of Science, Masaryk University, 602 00 Brno, Czech Republic; International Clinical Research Centre, St. Anne's University Hospital, 656 91 Brno, Czech Republic.
| |
Collapse
|
23
|
Zhou S, Fatma Z, Xue P, Mishra S, Cao M, Zhao H, Sweedler JV. Mass Spectrometry-Based High-Throughput Quantification of Bioproducts in Liquid Culture. Anal Chem 2023; 95:4067-4076. [PMID: 36790390 DOI: 10.1021/acs.analchem.2c04845] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
Abstract
To meet the ever-increasing need for high-throughput screening in metabolic engineering, information-rich, fast screening methods are needed. Mass spectrometry (MS) provides an efficient and general approach for metabolite screening and offers the capability of characterizing a broad range of analytes in a label-free manner, but often requires a range of sample clean-up and extraction steps. Liquid extraction surface analysis (LESA) coupled MS is an image-guided MS surface analysis approach that directly samples and introduces metabolites from a surface to MS. Here, we combined the advantages of LESA-MS and an acoustic liquid handler with stable isotope-labeled internal standards. This approach provides absolute quantitation of target chemicals from liquid culture-dried droplets and enables high-throughput quantitative screening for microbial metabolites. In this study, LESA-MS was successfully applied to quantify several different metabolites (itaconic acid, triacetic acid lactone, and palmitic acid) from different yeast strains in different mediums, demonstrating its versatility, accuracy, and efficiency across a range of microbial engineering applications.
Collapse
Affiliation(s)
- Shuaizhen Zhou
- Department of Energy Center for Advanced Bioenergy and Bioproducts Innovation, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Zia Fatma
- Department of Energy Center for Advanced Bioenergy and Bioproducts Innovation, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Pu Xue
- Department of Energy Center for Advanced Bioenergy and Bioproducts Innovation, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Shekhar Mishra
- Department of Energy Center for Advanced Bioenergy and Bioproducts Innovation, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Mingfeng Cao
- Department of Energy Center for Advanced Bioenergy and Bioproducts Innovation, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Huimin Zhao
- Department of Energy Center for Advanced Bioenergy and Bioproducts Innovation, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Department of Chemical and Biomolecular Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Department of Biochemistry, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Jonathan V Sweedler
- Department of Energy Center for Advanced Bioenergy and Bioproducts Innovation, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| |
Collapse
|
24
|
Zhao X, Liang J, Chen Z, Jian R, Qian Y, Wang Y, Guo Z, Zhang W, Zhang Y, Yin H, Xia Y. sn-1 Specificity of Lysophosphatidylcholine Acyltransferase-1 Revealed by a Mass Spectrometry-Based Assay. Angew Chem Int Ed Engl 2023; 62:e202215556. [PMID: 36478519 DOI: 10.1002/anie.202215556] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2022] [Revised: 11/29/2022] [Accepted: 12/06/2022] [Indexed: 12/12/2022]
Abstract
Lysophosphatidylcholine acyltransferase-1 (LPCAT1) plays a critical role in the remodeling of phosphatidylcholines (PCs) in cellular lipidome. However, evidence is scarce regarding its sn-selectivity, viz. the preference of assembling acyl-Coenzyme A (CoA) at the C1 or C2-hydroxyl on a glycerol backbone because of difficulty to quantify the thus-formed PC sn-isomers. We have established a multiplexed assay to measure both sn- and acyl-chain selectivity of LPCAT1 toward a mixture of acyl-CoAs by integrating isomer-resolving tandem mass spectrometry. Our findings reveal that LPCAT1 shows exclusive sn-1 specificity regardless of the identity of acyl-CoAs. We further confirm that elevated PC 18 : 1/16:0 relative to its sn-isomer results from an increased expression of LPCAT1 in human hepatocellular carcinoma (HCC) tissue as compared to normal liver tissue. MS imaging via desorption electrospray ionization of PC 18 : 1/16:0 thus enables visualization of HCC margins in human liver tissue at a molecular level.
Collapse
Affiliation(s)
- Xue Zhao
- MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biological, Department of Chemistry, Tsinghua University, Beijing, 100084, China
| | - Jiaqi Liang
- MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biological, Department of Chemistry, Tsinghua University, Beijing, 100084, China
| | | | - Ruijun Jian
- MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biological, Department of Chemistry, Tsinghua University, Beijing, 100084, China
| | - Yao Qian
- State key laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China
| | - Yunfang Wang
- Hepato-pancreato-biliary Center, Beijing Tsinghua Changgung Hospital, Institute for Precision Medicine, Tsinghua University, Beijing, 102218, China
| | - Zhiying Guo
- Hepato-pancreato-biliary Center, Beijing Tsinghua Changgung Hospital, Institute for Precision Medicine, Tsinghua University, Beijing, 102218, China
| | - Wenpeng Zhang
- State key laboratory of Precision Measurement Technology and Instruments, Department of Precision Instrument, Tsinghua University, Beijing, 100084, China
| | - Ying Zhang
- School of Pharmaceutical Sciences, Tsinghua University-Peking University Joint Center for Life Sciences, and Beijing Advanced Innovation Center for Structural Biology, Tsinghua University, Beijing, 100084, China
| | - Hang Yin
- School of Pharmaceutical Sciences, Tsinghua University-Peking University Joint Center for Life Sciences, and Beijing Advanced Innovation Center for Structural Biology, Tsinghua University, Beijing, 100084, China
| | - Yu Xia
- MOE Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biological, Department of Chemistry, Tsinghua University, Beijing, 100084, China
| |
Collapse
|
25
|
Dueñas ME, Peltier‐Heap RE, Leveridge M, Annan RS, Büttner FH, Trost M. Advances in high-throughput mass spectrometry in drug discovery. EMBO Mol Med 2023; 15:e14850. [PMID: 36515561 PMCID: PMC9832828 DOI: 10.15252/emmm.202114850] [Citation(s) in RCA: 45] [Impact Index Per Article: 22.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2021] [Revised: 10/03/2022] [Accepted: 10/07/2022] [Indexed: 12/15/2022] Open
Abstract
High-throughput (HT) screening drug discovery, during which thousands or millions of compounds are screened, remains the key methodology for identifying active chemical matter in early drug discovery pipelines. Recent technological developments in mass spectrometry (MS) and automation have revolutionized the application of MS for use in HT screens. These methods allow the targeting of unlabelled biomolecules in HT assays, thereby expanding the breadth of targets for which HT assays can be developed compared to traditional approaches. Moreover, these label-free MS assays are often cheaper, faster, and more physiologically relevant than competing assay technologies. In this review, we will describe current MS techniques used in drug discovery and explain their advantages and disadvantages. We will highlight the power of mass spectrometry in label-free in vitro assays, and its application for setting up multiplexed cellular phenotypic assays, providing an exciting new tool for screening compounds in cell lines, and even primary cells. Finally, we will give an outlook on how technological advances will increase the future use and the capabilities of mass spectrometry in drug discovery.
Collapse
Affiliation(s)
- Maria Emilia Dueñas
- Laboratory for Biomedical Mass Spectrometry, Biosciences InstituteNewcastle UniversityNewcastle‐upon‐TyneUK
| | - Rachel E Peltier‐Heap
- Discovery Analytical, Screening Profiling and Mechanistic Biology, GSK R&DStevenageUK
| | - Melanie Leveridge
- Discovery Analytical, Screening Profiling and Mechanistic Biology, GSK R&DStevenageUK
| | - Roland S Annan
- Discovery Analytical, Screening Profiling and Mechanistic Biology, GSK R&DStevenageUK
| | - Frank H Büttner
- Drug Discovery Sciences, High Throughput BiologyBoehringer Ingelheim Pharma GmbH&CoKGBiberachGermany
| | - Matthias Trost
- Laboratory for Biomedical Mass Spectrometry, Biosciences InstituteNewcastle UniversityNewcastle‐upon‐TyneUK
| |
Collapse
|
26
|
Ghosh J, Mendoza J, Cooks RG. Accelerated and Concerted Aza-Michael Addition and SuFEx Reaction in Microdroplets in Unitary and High-Throughput Formats. Angew Chem Int Ed Engl 2022; 61:e202214090. [PMID: 36253886 PMCID: PMC10099520 DOI: 10.1002/anie.202214090] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2022] [Indexed: 11/12/2022]
Abstract
The sulfur fluoride exchange (SuFEx) reaction is significant in drug discovery, materials science, and chemical biology. Conventionally, it involves installation of SO2 F followed by fluoride exchange by a catalyst. We report catalyst-free Aza-Michael addition to install SO2 F and then SuFEx reaction with amines, both occurring in concert, in microdroplets under ambient conditions. The microdroplet reaction is accelerated by a factor of ∼104 relative to the corresponding bulk reaction. We suggest that the superacidic microdroplet surface assists SuFEx reaction by protonating fluorine to create a good leaving group. The reaction scope was established by performing individual reactions in microdroplets of 18 amines in four solvents and confirmed using high-throughput desorption electrospray ionization experiments. The study demonstrates the value of microdroplet-assisted accelerated reactions in combination with high-throughput experimentation for characterization of reaction scope.
Collapse
Affiliation(s)
- Jyotirmoy Ghosh
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN 47907, USA
| | - Joshua Mendoza
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN 47907, USA
| | - R Graham Cooks
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN 47907, USA
| |
Collapse
|
27
|
Morato NM, Brown HM, Garcia D, Middlebrooks EH, Jentoft M, Chaichana K, Quiñones-Hinojosa A, Cooks RG. High-throughput analysis of tissue microarrays using automated desorption electrospray ionization mass spectrometry. Sci Rep 2022; 12:18851. [PMID: 36344609 PMCID: PMC9640715 DOI: 10.1038/s41598-022-22924-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 10/20/2022] [Indexed: 11/09/2022] Open
Abstract
Tissue microarrays (TMAs) are commonly used for the rapid analysis of large numbers of tissue samples, often in morphological assessments but increasingly in spectroscopic analysis, where specific molecular markers are targeted via immunostaining. Here we report the use of an automated high-throughput system based on desorption electrospray ionization (DESI) mass spectrometry (MS) for the rapid generation and online analysis of high-density (6144 samples/array) TMAs, at rates better than 1 sample/second. Direct open-air analysis of tissue samples (hundreds of nanograms) not subjected to prior preparation, plus the ability to provide molecular characterization by tandem mass spectrometry (MS/MS), make this experiment versatile and applicable to both targeted and untargeted analysis in a label-free manner. These capabilities are demonstrated in a proof-of-concept study of frozen brain tissue biopsies where we showcase (i) a targeted MS/MS application aimed at identification of isocitrate dehydrogenase mutation in glioma samples and (ii) an untargeted MS tissue type classification using lipid profiles and correlation with tumor cell percentage estimates from histopathology. The small sample sizes and large sample numbers accessible with this methodology make for a powerful analytical system that facilitates the identification of molecular markers for later use in intraoperative applications to guide precision surgeries and ultimately improve patient outcomes.
Collapse
Affiliation(s)
- Nicolás M. Morato
- grid.169077.e0000 0004 1937 2197Department of Chemistry, Purdue Center for Cancer Research, and Bindley Bioscience Center, Purdue University, 560 Oval Drive, West Lafayette, IN 47907 USA
| | - Hannah Marie Brown
- grid.169077.e0000 0004 1937 2197Department of Chemistry, Purdue Center for Cancer Research, and Bindley Bioscience Center, Purdue University, 560 Oval Drive, West Lafayette, IN 47907 USA ,grid.4367.60000 0001 2355 7002Present Address: Department of Pathology and Immunology, Washington University School of Medicine, St. Louis, MO USA
| | - Diogo Garcia
- grid.417467.70000 0004 0443 9942Department of Neurosurgery, Mayo Clinic, Jacksonville, FL USA
| | - Erik H. Middlebrooks
- grid.417467.70000 0004 0443 9942Department of Neurosurgery, Mayo Clinic, Jacksonville, FL USA ,grid.417467.70000 0004 0443 9942Department of Radiology, Mayo Clinic, Jacksonville, FL USA
| | - Mark Jentoft
- grid.417467.70000 0004 0443 9942Department of Laboratory Medicine and Pathology, Mayo Clinic, Jacksonville, FL USA
| | - Kaisorn Chaichana
- grid.417467.70000 0004 0443 9942Department of Neurosurgery, Mayo Clinic, Jacksonville, FL USA
| | | | - R. Graham Cooks
- grid.169077.e0000 0004 1937 2197Department of Chemistry, Purdue Center for Cancer Research, and Bindley Bioscience Center, Purdue University, 560 Oval Drive, West Lafayette, IN 47907 USA
| |
Collapse
|
28
|
Lu L, Hu X, Zeng R, Lin Q, Huang X, Li M, Tang D. Dual-mode colorimetric-photothermal sensing platform of acetylcholinesterase activity based on the peroxidase-like activity of Fe-N-C nanozyme. Anal Chim Acta 2022; 1229:340383. [PMID: 36156227 DOI: 10.1016/j.aca.2022.340383] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 09/08/2022] [Indexed: 11/01/2022]
Abstract
Sensors based on colorimetry, fluorescence, and electrochemistry have been widely employed to detect acetylcholinesterase and its inhibitors, however, there are only a minority of strategies for AChE detection based on photothermal method. This work reports a versatile dual-mode colorimetric and photothermal biosensing platform for acetylcholinesterase (AChE) detection and its inhibitor (paraoxon-ethyl, a model of AChE inhibitors) monitor based on Fe-N-C/H2O2/3,3',5,5'-tetramethylbenzidine (TMB) system. The Fe-N-C with abundant active Fe-Nx sites shows outstanding peroxidase-mimicking activity and can be used to promote the generation of •OH by H2O2 to oxidize TMB. However, the introduction of mercapto molecules tending to coordinate with metal atoms result in the block of action site in Fe-N-C, thereby decrease its peroxidase-mimetic activity. The designed biosensor principle is based on the block of active sites of Fe-N-C by thiocholine (TCh, one kind of mercapto molecules) that can be produced by acetylthiocholine (ATCh) in the presence of AChE. Under optimum conditions, the limit of detection (LOD) for AChE activity is 1.9 mU mL-1 (colorimetric) and 2.2 mU mL-1 (photothermal), while for paraoxon-ethyl is 0.012 μg mL-1 (colorimetric) and 0.013 μg mL-1 (photothermal), respectively. The assay we proposed not only can be designed to monitor AChE detection and its inhibitors, but also can be easily extended for the detection of other biomolecules relate to the generation or consumption of H2O2.
Collapse
Affiliation(s)
- Liling Lu
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Xuehan Hu
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Ruijin Zeng
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Qianyun Lin
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Xue Huang
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, People's Republic of China
| | - Meijin Li
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, People's Republic of China.
| | - Dianping Tang
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, People's Republic of China.
| |
Collapse
|
29
|
Shi L, Habib A, Bi L, Hong H, Begum R, Wen L. Ambient Ionization Mass Spectrometry: Application and Prospective. Crit Rev Anal Chem 2022; 54:1584-1633. [PMID: 36206159 DOI: 10.1080/10408347.2022.2124840] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/10/2022]
Abstract
Mass spectrometry (MS) is a formidable analytical tool for the analysis of non-polar to polar compounds individually and/or from mixtures, providing information on the molecular weights and chemical structures of the analytes. During the last more than one-decade, ambient ionization mass spectrometry (AIMS) has developed quickly, producing a wide range of platforms and proving scientific improvements in a variety of domains, from biological imaging to quick quality control. These methods have made it possible to detect target analytes in real time without sample preparation in an open environment, and they can be connected to any MS system with an atmospheric pressure interface. They also have the ability to analyze explosives, illicit drugs, disease diagnostics, drugs in biological samples, adulterants in food and agricultural products, reaction progress, and environmental monitoring. The development of novel ambient ionization techniques, such as probe electrospray ionization, paper spray ionization, and fiber spray ionization, employed even at picolitre to femtolitre solution levels to provide femtogram to attogram levels of the target analytes. The special characteristic of this ambient ion source, which has been extensively used, is the noninvasive property of PESI of examination of biological real samples. The results in the current review supports the idea that AIMS has emerged as a pioneer in MS-based approaches and that methods will continue to be developed along with improvements to existing ones in the near future.
Collapse
Affiliation(s)
- Lulu Shi
- Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai, China
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
| | - Ahsan Habib
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
- Department of Chemistry, University of Dhaka, Dhaka, Bangladesh
| | - Lei Bi
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
| | - Huanhuan Hong
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
| | - Rockshana Begum
- Department of Chemistry, Shahjalal University of Science and Technology, Sylhet, Bangladesh
| | - Luhong Wen
- China Innovation Instrument Co., Ltd, Ningbo, Zhejiang, China
- The Research Institute of Advanced Technologies, Ningbo University, Ningbo, Zhejiang, China
| |
Collapse
|
30
|
Pu F, Ugrin SA, Radosevich AJ, Chang-Yen D, Sawicki JW, Talaty NN, Elsen NL, Williams JD. High-Throughput Intact Protein Analysis for Drug Discovery Using Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry. Anal Chem 2022; 94:13566-13574. [PMID: 36129783 DOI: 10.1021/acs.analchem.2c03211] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Mass spectrometry (MS) is the primary analytical tool used to characterize proteins within the biopharmaceutical industry. Electrospray ionization (ESI) coupled to liquid chromatography (LC) is the current gold standard for intact protein analysis. However, inherent speed limitations of LC/MS prevent analysis of large sample numbers (>1000) in a day. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI-MS), an ambient ionization MS technology, has recently been established as a platform for high-throughput small molecule analysis. Here, we report the applications of such a system for the analysis of intact proteins commonly performed within the drug discovery process. A wide molecular weight range of proteins 10-150 kDa was detected on the system with improved tolerance to salts and buffers compared to ESI. With high concentrations and model proteins, a sample rate of up to 22 Hz was obtained. For proteins at low concentrations and in buffers used in commonly employed assays, robust data at a sample rate of 1.5 Hz were achieved, which is ∼22× faster than current technologies used for high-throughput ESI-MS-based protein assays. In addition, two multiplexed plate-based high-throughput sample cleanup methods were coupled to IR-MALDESI-MS to enable analysis of samples containing excessive amounts of salts and buffers without fully compromising productivity. Example experiments, which leverage the speed of the IR-MALDESI-MS system to monitor NISTmAb reduction, protein autophosphorylation, and compound binding kinetics in near real time, are demonstrated.
Collapse
Affiliation(s)
- Fan Pu
- AbbVie Inc, 1 North Waukegan Rd., North Chicago, Illinois 60064, United States
| | - Scott A Ugrin
- AbbVie Inc, 1 North Waukegan Rd., North Chicago, Illinois 60064, United States
| | - Andrew J Radosevich
- AbbVie Inc, 1 North Waukegan Rd., North Chicago, Illinois 60064, United States
| | - David Chang-Yen
- AbbVie Inc, 1 North Waukegan Rd., North Chicago, Illinois 60064, United States
| | - James W Sawicki
- AbbVie Inc, 1 North Waukegan Rd., North Chicago, Illinois 60064, United States
| | - Nari N Talaty
- AbbVie Inc, 1 North Waukegan Rd., North Chicago, Illinois 60064, United States
| | - Nathaniel L Elsen
- AbbVie Inc, 1 North Waukegan Rd., North Chicago, Illinois 60064, United States
| | - Jon D Williams
- AbbVie Inc, 1 North Waukegan Rd., North Chicago, Illinois 60064, United States
| |
Collapse
|
31
|
Wohlgemuth R, Littlechild J. Complexity reduction and opportunities in the design, integration and intensification of biocatalytic processes for metabolite synthesis. Front Bioeng Biotechnol 2022; 10:958606. [PMID: 35935499 PMCID: PMC9355135 DOI: 10.3389/fbioe.2022.958606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 06/28/2022] [Indexed: 11/13/2022] Open
Abstract
The biosynthesis of metabolites from available starting materials is becoming an ever important area due to the increasing demands within the life science research area. Access to metabolites is making essential contributions to analytical, diagnostic, therapeutic and different industrial applications. These molecules can be synthesized by the enzymes of biological systems under sustainable process conditions. The facile synthetic access to the metabolite and metabolite-like molecular space is of fundamental importance. The increasing knowledge within molecular biology, enzyme discovery and production together with their biochemical and structural properties offers excellent opportunities for using modular cell-free biocatalytic systems. This reduces the complexity of synthesizing metabolites using biological whole-cell approaches or by classical chemical synthesis. A systems biocatalysis approach can provide a wealth of optimized enzymes for the biosynthesis of already identified and new metabolite molecules.
Collapse
Affiliation(s)
- Roland Wohlgemuth
- Institute of Molecular and Industrial Biotechnology, Lodz University of Technology, Lodz, Poland
- Swiss Coordination Committee for Biotechnology, Zurich, Switzerland
| | - Jennifer Littlechild
- Henry Wellcome Building for Biocatalysis, Biosciences, University of Exeter, Exeter, United Kingdom
| |
Collapse
|
32
|
Liu C. Acoustic Ejection Mass Spectrometry: Fundamentals and Applications in High-Throughput Drug Discovery. Expert Opin Drug Discov 2022; 17:775-787. [DOI: 10.1080/17460441.2022.2084069] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Affiliation(s)
- Chang Liu
- SCIEX, 71 Four Valley Drive, Concord, ON, L4K 4V8, Canada
| |
Collapse
|
33
|
Kulathunga SC, Morato NM, Zhou Q, Cooks RG, Mesecar AD. Desorption Electrospray Ionization Mass Spectrometry Assay for Label-Free Characterization of SULT2B1b Enzyme Kinetics. ChemMedChem 2022; 17:e202200043. [PMID: 35080134 PMCID: PMC10112463 DOI: 10.1002/cmdc.202200043] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Indexed: 11/06/2022]
Abstract
The sulfotransferase (SULT) 2B1b, which catalyzes the sulfonation of 3β-hydroxysteroids, has been identified as a potential target for prostate cancer treatment. However, a major limitation for SULT2B1b-targeted drug discovery is the lack of robust assays compatible with high-throughput screening and inconsistency in reported kinetic data. For this reason, we developed a novel label-free assay based on high-throughput (>1 Hz) desorption electrospray ionization mass spectrometry (DESI-MS) for the direct quantitation of the sulfoconjugated product (CV<10 %; <1 ng analyte). The performance of this DESI-based assay was compared against a new fluorometric coupled-enzyme method that we also developed. Both methodologies provided consistent kinetic data for the reaction of SULT2B1b with its major substrates, indicating the affinity trend pregnenolone>DHEA>cholesterol, for both the phospho-mimetic and wild-type SULT2B1b forms. The novel DESI-MS assay developed here is likely generalizable to other drug discovery efforts and is particularly promising for identification of SULT2B1b inhibitors with potential as prostate cancer therapeutics.
Collapse
Affiliation(s)
- Samadhi C Kulathunga
- Department of Biochemistry, Department of Biological Sciences, Department of Chemistry, and Purdue Center for Cancer Research, Purdue University, Hockmeyer Hall of Structural Biology, 240 S. Martin Jischke Drive, West Lafayette, IN 47907, USA
| | - Nicolás M Morato
- Department of Chemistry, Bindley Bioscience Center, and Purdue Center for Cancer Research, Purdue University, Wetherill Laboratory of Chemistry, 560 Oval Drive, West Lafayette, IN 47907, USA
| | - Qing Zhou
- Department of Biochemistry, Department of Biological Sciences, Department of Chemistry, and Purdue Center for Cancer Research, Purdue University, Hockmeyer Hall of Structural Biology, 240 S. Martin Jischke Drive, West Lafayette, IN 47907, USA
| | - R Graham Cooks
- Department of Chemistry, Bindley Bioscience Center, and Purdue Center for Cancer Research, Purdue University, Wetherill Laboratory of Chemistry, 560 Oval Drive, West Lafayette, IN 47907, USA
| | - Andrew D Mesecar
- Department of Biochemistry, Department of Biological Sciences, Department of Chemistry, and Purdue Center for Cancer Research, Purdue University, Hockmeyer Hall of Structural Biology, 240 S. Martin Jischke Drive, West Lafayette, IN 47907, USA
| |
Collapse
|
34
|
Towards one sample per second for mass spectrometric screening of engineered microbial strains. Curr Opin Biotechnol 2022; 76:102725. [PMID: 35489307 DOI: 10.1016/j.copbio.2022.102725] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2021] [Revised: 03/03/2022] [Accepted: 03/20/2022] [Indexed: 12/11/2022]
Abstract
Microbial cell factories convert renewable feedstocks into desirable chemicals and materials. Due to the lack of predictive modeling, high-throughput screening remains essential for microbial strain engineering. Mass spectrometry (MS) is a label-free modality with superior sensitivity and chemical specificity. Critical advances in improving the throughput of MS assays on complex microbial samples include massively parallel cultivation, robotic sample preparation, and chromatography-free instrumentation. Here, we review the recent development and application of rapid MS assays in screening microbial libraries, achieving or approaching a rate of one sample per second. We conclude with unique challenges associated with MS screening of strain libraries and discuss future solutions.
Collapse
|
35
|
Qiu L, Morato NM, Huang KH, Cooks RG. Spontaneous Water Radical Cation Oxidation at Double Bonds in Microdroplets. Front Chem 2022; 10:903774. [PMID: 35559217 PMCID: PMC9086510 DOI: 10.3389/fchem.2022.903774] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Accepted: 04/11/2022] [Indexed: 12/20/2022] Open
Abstract
Spontaneous oxidation of compounds containing diverse X=Y moieties (e.g., sulfonamides, ketones, esters, sulfones) occurs readily in organic-solvent microdroplets. This surprising phenomenon is proposed to be driven by the generation of an intermediate species [M+H2O]+·: a covalent adduct of water radical cation (H2O+·) with the reactant molecule (M). The adduct is observed in the positive ion mass spectrum while its formation in the interfacial region of the microdroplet (i.e., at the air-droplet interface) is indicated by the strong dependence of the oxidation product formation on the spray distance (which reflects the droplet size and consequently the surface-to-volume ratio) and the solvent composition. Importantly, based on the screening of a ca. 21,000-compound library and the detailed consideration of six functional groups, the formation of a molecular adduct with the water radical cation is a significant route to ionization in positive ion mode electrospray, where it is favored in those compounds with X=Y moieties which lack basic groups. A set of model monofunctional systems was studied and in one case, benzyl benzoate, evidence was found for oxidation driven by hydroxyl radical adduct formation followed by protonation in addition to the dominant water radical cation addition process. Significant implications of molecular ionization by water radical cations for oxidation processes in atmospheric aerosols, analytical mass spectrometry and small-scale synthesis are noted.
Collapse
|
36
|
Radosevich AJ, Pu F, Chang-Yen D, Sawicki JW, Talaty NN, Elsen NL, Williams JD, Pan JY. Ultra-High-Throughput Ambient MS: Direct Analysis at 22 Samples per Second by Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry. Anal Chem 2022; 94:4913-4918. [PMID: 35290016 DOI: 10.1021/acs.analchem.1c04605] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry is an ambient-direct sampling method that is being developed for high-throughput, label-free, biochemical screening of large-scale compound libraries. Here, we report the development of an ultra-high-throughput continuous motion IR-MALDESI sampling approach capable of acquiring data at rates up to 22.7 samples per second in a 384-well microtiter plate. At top speed, less than 1% analyte carryover is observed from well-to-well, and signal intensity relative standard deviations (RSD) of 11.5% and 20.9% for 3 μM 1-hydroxymidazolam and 12 μM dextrorphan, respectively, are achieved. The ability to perform parallel kinetics studies on 384 samples with a ∼30 s time resolution using an isocitrate dehydrogenase 1 (IDH1) enzyme assay is shown. Finally, we demonstrate the repeatability and throughput of our approach by measuring 115200 samples from 300 microtiter plate reads consecutively over 5.54 h with RSDs under 8.14% for each freshly introduced plate. Taken together, these results demonstrate the use of IR-MALDESI at sample acquisition rates that surpass other currently reported direct sampling mass spectrometry approaches used for high-throughput compound screening.
Collapse
Affiliation(s)
- Andrew J Radosevich
- AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States
| | - Fan Pu
- AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States
| | - David Chang-Yen
- AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States
| | - James W Sawicki
- AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States
| | - Nari N Talaty
- AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States
| | - Nathaniel L Elsen
- AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States
| | - Jon D Williams
- AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States
| | - Jeffrey Y Pan
- AbbVie Inc., 1 North Waukegan Road, North Chicago, Illinois 60064, United States
| |
Collapse
|
37
|
Huang KH, Ghosh J, Xu S, Cooks RG. Late-Stage Functionalization and Characterization of Drugs by High-Throughput Desorption Electrospray Ionization Mass Spectrometry. Chempluschem 2022; 87:e202100449. [PMID: 34985208 DOI: 10.1002/cplu.202100449] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2021] [Revised: 11/24/2021] [Indexed: 12/15/2022]
Abstract
Late-stage functionalization (LSF) of drug molecules is an approach to generate modified molecules that retain functional groups present in the active drugs. Here, we report a study that seeks to characterize the potential value of high-throughput desorption electrospray ionization mass spectrometry (HT DESI-MS) for small-scale rapid LSF. In conventional route screening, HT-based DESI-MS provides contactless, rapid analysis, reliable and reproducible data, minimal sample requirement, and exceptional tolerance to high salt concentrations. Ezetimibe (E), an established hypertension drug, is targeted for modification by LSF. C-H alkenylation and azo-click reactions are utilized to explore this approach to synthesis and analytical characterization. The effect of choice of reactant, stoichiometry, catalyst, and solvent are studied for both reactions using high throughput DESI-MS experiments. Optimum conditions for the formation of LSF products are established with identification by tandem mass spectrometry (MS/MS).
Collapse
Affiliation(s)
- Kai-Hung Huang
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907, USA
| | - Jyotirmoy Ghosh
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907, USA
| | - Shiqing Xu
- Department of Chemistry, Texas A&M University, 580 Ross Street, College Station, TX, 77843, USA
| | - R Graham Cooks
- Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47907, USA
| |
Collapse
|
38
|
Overhoff B, Falls Z, Mangione W, Samudrala R. A Deep-Learning Proteomic-Scale Approach for Drug Design. Pharmaceuticals (Basel) 2021; 14:1277. [PMID: 34959678 PMCID: PMC8709297 DOI: 10.3390/ph14121277] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 11/27/2021] [Accepted: 11/29/2021] [Indexed: 12/26/2022] Open
Abstract
Computational approaches have accelerated novel therapeutic discovery in recent decades. The Computational Analysis of Novel Drug Opportunities (CANDO) platform for shotgun multitarget therapeutic discovery, repurposing, and design aims to improve their efficacy and safety by employing a holistic approach that computes interaction signatures between every drug/compound and a large library of non-redundant protein structures corresponding to the human proteome fold space. These signatures are compared and analyzed to determine if a given drug/compound is efficacious and safe for a given indication/disease. In this study, we used a deep learning-based autoencoder to first reduce the dimensionality of CANDO-computed drug-proteome interaction signatures. We then employed a reduced conditional variational autoencoder to generate novel drug-like compounds when given a target encoded "objective" signature. Using this approach, we designed compounds to recreate the interaction signatures for twenty approved and experimental drugs and showed that 16/20 designed compounds were predicted to be significantly (p-value ≤ 0.05) more behaviorally similar relative to all corresponding controls, and 20/20 were predicted to be more behaviorally similar relative to a random control. We further observed that redesigns of objectives developed via rational drug design performed significantly better than those derived from natural sources (p-value ≤ 0.05), suggesting that the model learned an abstraction of rational drug design. We also show that the designed compounds are structurally diverse and synthetically feasible when compared to their respective objective drugs despite consistently high predicted behavioral similarity. Finally, we generated new designs that enhanced thirteen drugs/compounds associated with non-small cell lung cancer and anti-aging properties using their predicted proteomic interaction signatures. his study represents a significant step forward in automating holistic therapeutic design with machine learning, enabling the rapid generation of novel, effective, and safe drug leads for any indication.
Collapse
Affiliation(s)
| | | | | | - Ram Samudrala
- Department of Biomedical Informatics, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, Buffalo, NY 14203, USA; (B.O.); (Z.F.); (W.M.)
| |
Collapse
|
39
|
Inter-platform assessment of performance of high-throughput desorption electrospray ionization mass spectrometry. TALANTA OPEN 2021. [DOI: 10.1016/j.talo.2021.100046] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023] Open
|
40
|
Morato NM, Le MT, Holden DT, Graham Cooks R. Automated High-Throughput System Combining Small-Scale Synthesis with Bioassays and Reaction Screening. SLAS Technol 2021; 26:555-571. [PMID: 34697962 DOI: 10.1177/24726303211047839] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
The Purdue Make It system is a unique automated platform capable of small-scale in situ synthesis, screening small-molecule reactions, and performing direct label-free bioassays. The platform is based on desorption electrospray ionization (DESI), an ambient ionization method that allows for minimal sample workup and is capable of accelerating reactions in secondary droplets, thus conferring unique advantages compared with other high-throughput screening technologies. By combining DESI with liquid handling robotics, the system achieves throughputs of more than 1 sample/s, handling up to 6144 samples in a single run. As little as 100 fmol/spot of analyte is required to perform both initial analysis by mass spectrometry (MS) and further MSn structural characterization. The data obtained are processed using custom software so that results are easily visualized as interactive heatmaps of reaction plates based on the peak intensities of m/z values of interest. In this paper, we review the system's capabilities as described in previous publications and demonstrate its utilization in two new high-throughput campaigns: (1) the screening of 188 unique combinatorial reactions (24 reaction types, 188 unique reaction mixtures) to determine reactivity trends and (2) label-free studies of the nicotinamide N-methyltransferase enzyme directly from the bioassay buffer. The system's versatility holds promise for several future directions, including the collection of secondary droplets containing the products from successful reaction screening measurements, the development of machine learning algorithms using data collected from compound library screening, and the adaption of a variety of relevant bioassays to high-throughput MS.
Collapse
Affiliation(s)
- Nicolás M Morato
- Department of Chemistry and Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, USA
| | - MyPhuong T Le
- Department of Chemistry and Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, USA
| | - Dylan T Holden
- Department of Chemistry and Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, USA
| | - R Graham Cooks
- Department of Chemistry and Center for Analytical Instrumentation Development, Purdue University, West Lafayette, IN, USA
| |
Collapse
|
41
|
Abstract
The market for industrial enzymes has witnessed constant growth, which is currently around 7% a year, projected to reach $10.5 billion in 2024. Lipases are hydrolase enzymes naturally responsible for triglyceride hydrolysis. They are the most expansively used industrial biocatalysts, with wide application in a broad range of industries. However, these biocatalytic processes are usually limited by the low stability of the enzyme, the half-life time, and the processes required to solve these problems are complex and lack application feasibility at the industrial scale. Emerging technologies create new materials for enzyme carriers and sophisticate the well-known immobilization principles to produce more robust, eco-friendlier, and cheaper biocatalysts. Therefore, this review discusses the trending studies and industrial applications of the materials and protocols for lipase immobilization, analyzing their advantages and disadvantages. Finally, it summarizes the current challenges and potential alternatives for lipases at the industrial level.
Collapse
|
42
|
Hu W, Zhou W, Wang C, Liu Z, Chen Z. Rapid Analysis of Biological Samples Using Monolithic Polymer-Based In-Tube Solid-Phase Microextraction with Direct Mass Spectrometry. ACS APPLIED BIO MATERIALS 2021; 4:6236-6243. [DOI: 10.1021/acsabm.1c00551] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Wei Hu
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, Hubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticals, Wuhan University School of Pharmaceutical Sciences, No. 185 Donghu Road, Wuchang District, Wuhan 430071, China
- State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Beijing 100080, China
| | - Wei Zhou
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, Hubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticals, Wuhan University School of Pharmaceutical Sciences, No. 185 Donghu Road, Wuchang District, Wuhan 430071, China
- State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Beijing 100080, China
| | - Chenlu Wang
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, Hubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticals, Wuhan University School of Pharmaceutical Sciences, No. 185 Donghu Road, Wuchang District, Wuhan 430071, China
| | - Zichun Liu
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, Hubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticals, Wuhan University School of Pharmaceutical Sciences, No. 185 Donghu Road, Wuchang District, Wuhan 430071, China
| | - Zilin Chen
- Key Laboratory of Combinatorial Biosynthesis and Drug Discovery, Ministry of Education, Hubei Province Engineering and Technology Research Center for Fluorinated Pharmaceuticals, Wuhan University School of Pharmaceutical Sciences, No. 185 Donghu Road, Wuchang District, Wuhan 430071, China
- State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Beijing 100080, China
| |
Collapse
|
43
|
Le MT, Morato NM, Kaerner A, Welch CJ, Cooks RG. Fragmentation of Polyfunctional Compounds Recorded Using Automated High-Throughput Desorption Electrospray Ionization. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2021; 32:2261-2273. [PMID: 34280312 DOI: 10.1021/jasms.1c00176] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Using desorption electrospray ionization (DESI) as part of an automated high-throughput system, tandem mass spectra of the compounds in a pharmaceutical library were recorded in the positive mode under standardized conditions. Quality control filtering yielded an MS/MS library of 16 662 spectra. Fragmentation of subsets of the compounds in the library chosen to contain a single instance of a particular functional group (amide, piperazine, sulfonamide) was predicted by experts, and the results were compared with the experimental data. Expert performance was good to excellent for all the cases evaluated. Substituents on the functional groups were found to exert important secondary control over the fragmentation, with the main effect observed being product ion stabilization by aromatic substitution, which was consistent across the different groups evaluated. These substituent effects are generally explicable in terms of standard physical organic chemistry considerations of product ion stability as controlling fragmentation. A somewhat unexpected feature was the incidence of homolytic cleavages, driven by the stability of substituted amine radical cations. The findings of this study are intended to lay the groundwork for machine learning approaches to performing MS/MS spectrum → structure and structure → MS/MS spectrum operations on the same experimental data set. The effort involved and the success achieved in computer-aided interpretation, now underway, will be compared with the expert performance as described here.
Collapse
Affiliation(s)
- MyPhuong T Le
- Department of Chemistry and Bindley Bioscience Center, Purdue University, West Lafayette, Indiana 47907, United States
| | - Nicolás M Morato
- Department of Chemistry and Bindley Bioscience Center, Purdue University, West Lafayette, Indiana 47907, United States
| | - Andreas Kaerner
- Discovery Chemistry Research and Technologies, Eli Lilly and Company, Lilly Corporate Center, Indianapolis, Indiana 46285, United States
| | - Christopher J Welch
- Indiana Consortium for Analytical Science and Engineering (ICASE), Indianapolis, Indiana 46202, United States
| | - R Graham Cooks
- Department of Chemistry and Bindley Bioscience Center, Purdue University, West Lafayette, Indiana 47907, United States
| |
Collapse
|
44
|
Li Y, Huang KH, Morato NM, Cooks RG. Glass surface as strong base, 'green' heterogeneous catalyst and degradation reagent. Chem Sci 2021; 12:9816-9822. [PMID: 34349955 PMCID: PMC8294000 DOI: 10.1039/d1sc02708e] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Accepted: 06/23/2021] [Indexed: 12/18/2022] Open
Abstract
Systematic screening of accelerated chemical reactions at solid/solution interfaces has been carried out in high-throughput fashion using desorption electrospray ionization mass spectrometry and it provides evidence that glass surfaces accelerate various base-catalyzed chemical reactions. The reaction types include elimination, solvolysis, condensation and oxidation, whether or not the substrates are pre-charged. In a detailed mechanistic study, we provide evidence using nanoESI showing that glass surfaces can act as strong bases and convert protic solvents into their conjugate bases which then act as bases/nucleophiles when participating in chemical reactions. In aprotic solvents such as acetonitrile, glass surfaces act as 'green' heterogeneous catalysts that can be recovered and reused after simple rinsing. Besides their use in organic reaction catalysis, glass surfaces are also found to act as degradation reagents for phospholipids with increasing extents of degradation occurring at low concentrations. This finding suggests that the storage of base/nucleophile-labile compounds or lipids in glass containers should be avoided.
Collapse
Affiliation(s)
- Yangjie Li
- Department of Chemistry, Purdue University West Lafayette IN 47907 USA
| | - Kai-Hung Huang
- Department of Chemistry, Purdue University West Lafayette IN 47907 USA
| | - Nicolás M Morato
- Department of Chemistry, Purdue University West Lafayette IN 47907 USA
| | - R Graham Cooks
- Department of Chemistry, Purdue University West Lafayette IN 47907 USA
| |
Collapse
|
45
|
Ultrafast enzymatic digestion of deoxyribonucleic acid in aqueous microdroplets for sequence discrimination and identification. QRB DISCOVERY 2021; 2:e4. [PMID: 34192264 PMCID: PMC8185430 DOI: 10.1017/qrd.2021.2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Revised: 04/05/2021] [Accepted: 05/07/2021] [Indexed: 12/31/2022] Open
Abstract
We report the use of aqueous microdroplets to accelerate deoxyribonucleic acid (DNA) fragmentation by deoxyribonuclease I (DNase I), and we present a simple, ultrafast approach named DNA fragment mass fingerprinting to discriminate different DNA sequences by comparing their fragment mass patterns. DNA fragmentation in tiny microdroplets, which was produced by electrosonically spraying (+3 kV) a room temperature aqueous solution containing 10 μM DNA and 10 μg ml−1 DNase I from a homemade setup, takes less than 1 ms. High differentiation/identification fidelity could be obtained by applying a cosine correlation measure for similarity assessment between two fragment mass patterns, which compares both mass-to-charge ratios (m/z) with an error tolerance of 5 ppm and the peaks’ relative intensities. A single-nucleotide mutation in the sequence of bases, as exemplified by the sickle cell anemia mutation, is differentiated by setting a cutoff value of similarity at 90%. The order change of two adjacent bases in the sequence could still be well discriminated with a similarity of only 62% between the fragment mass patterns of the two similar sequences, which have the same molecular weights and thus cannot be differentiated by gel electrophoresis or direct mass detection by mass spectrometry. Compared to traditional genotyping methods, such as quantitative real-time polymerase chain reaction, the identification process with our approach could be completed within several minutes without any other expensive and complicated reagents or experimental steps. The potential of our approach for convenient and fast microbe genetic discrimination or identification is further demonstrated by differentiating the Orf1ab gene fragments of two similar coronaviruses with a very high sequence homologous rate of 96%, SARS-CoV-2 and bat-SL-CoVZC45, with a similarity of 0% between their fragment mass patterns.
Collapse
|
46
|
Pu F, Radosevich AJ, Sawicki JW, Chang-Yen D, Talaty NN, Gopalakrishnan SM, Williams JD, Elsen NL. High-Throughput Label-Free Biochemical Assays Using Infrared Matrix-Assisted Desorption Electrospray Ionization Mass Spectrometry. Anal Chem 2021; 93:6792-6800. [PMID: 33885291 DOI: 10.1021/acs.analchem.1c00737] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Mass spectrometry (MS) can provide high sensitivity and specificity for biochemical assays without the requirement of labels, eliminating the risk of assay interference. However, its use had been limited to lower-throughput assays due to the need for chromatography to overcome ion suppression from the sample matrix. Direct analysis without chromatography has the potential for high throughput if sensitivity is sufficient despite the presence of a matrix. Here, we report and demonstrate a novel direct analysis high-throughput MS system based on infrared matrix-assisted desorption electrospray ionization (IR-MALDESI) that has a potential acquisition rate of 33 spectra/s. We show the development of biochemical assays in standard buffers for wild-type isocitrate dehydrogenase 1 (IDH1), diacylglycerol kinase zeta (DGKζ), and p300 histone acetyltransferase (P300) to demonstrate the suitability of this system for a broad range of high-throughput lead discovery assays. A proof-of-concept pilot screen of ∼3k compounds is also shown for IDH1 and compared to a previously reported fluorescence-based assay. We were able to obtain reliable data at a speed amenable for high-throughput screening of large-scale compound libraries.
Collapse
Affiliation(s)
- Fan Pu
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, United States
| | - Andrew J Radosevich
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, United States
| | - James W Sawicki
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, United States
| | - David Chang-Yen
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, United States
| | - Nari N Talaty
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, United States
| | - Sujatha M Gopalakrishnan
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, United States
| | - Jon D Williams
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, United States
| | - Nathaniel L Elsen
- Drug Discovery Science and Technology, AbbVie Inc., North Chicago, Illinois 60064, United States
| |
Collapse
|
47
|
Kempa EE, Galman JL, Parmeggiani F, Marshall JR, Malassis J, Fontenelle CQ, Vendeville JB, Linclau B, Charnock SJ, Flitsch SL, Turner NJ, Barran PE. Rapid Screening of Diverse Biotransformations for Enzyme Evolution. JACS AU 2021; 1:508-516. [PMID: 34056634 PMCID: PMC8154213 DOI: 10.1021/jacsau.1c00027] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Indexed: 06/12/2023]
Abstract
The lack of label-free high-throughput screening technologies presents a major bottleneck in the identification of active and selective biocatalysts, with the number of variants often exceeding the capacity of traditional analytical platforms to assess their activity in a practical time scale. Here, we show the application of direct infusion of biotransformations to the mass spectrometer (DiBT-MS) screening to a variety of enzymes, in different formats, achieving sample throughputs equivalent to ∼40 s per sample. The heat map output allows rapid selection of active enzymes within 96-well plates facilitating identification of industrially relevant biocatalysts. This DiBT-MS screening workflow has been applied to the directed evolution of a phenylalanine ammonia lyase (PAL) as a case study, enhancing its activity toward electron-rich cinnamic acid derivatives which are relevant to lignocellulosic biomass degradation. Additional benefits of the screening platform include the discovery of biocatalysts (kinases, imine reductases) with novel activities and the incorporation of ion mobility technology for the identification of product hits with increased confidence.
Collapse
Affiliation(s)
- Emily E Kempa
- School of Chemistry, University of Manchester, Manchester Institute of Biotechnology, 131 Princess Street, Manchester M1 7DN, United Kingdom
| | - James L Galman
- School of Chemistry, University of Manchester, Manchester Institute of Biotechnology, 131 Princess Street, Manchester M1 7DN, United Kingdom
| | - Fabio Parmeggiani
- Department of Chemistry, Materials and Chemical Engineering "G. Natta", Politecnico di Milano, Via Mancinelli 7, 20131 Milano, Italy
| | - James R Marshall
- School of Chemistry, University of Manchester, Manchester Institute of Biotechnology, 131 Princess Street, Manchester M1 7DN, United Kingdom
| | - Julien Malassis
- School of Chemistry, University of Southampton, Highfield, SO17 1BJ Southampton, United Kingdom
| | - Clement Q Fontenelle
- School of Chemistry, University of Southampton, Highfield, SO17 1BJ Southampton, United Kingdom
| | | | - Bruno Linclau
- School of Chemistry, University of Southampton, Highfield, SO17 1BJ Southampton, United Kingdom
| | - Simon J Charnock
- Prozomix Ltd., Building 4, West End Ind. Estate, Haltwhistle, Northumberland NE49 9HA, United Kingdom
| | - Sabine L Flitsch
- School of Chemistry, University of Manchester, Manchester Institute of Biotechnology, 131 Princess Street, Manchester M1 7DN, United Kingdom
| | - Nicholas J Turner
- School of Chemistry, University of Manchester, Manchester Institute of Biotechnology, 131 Princess Street, Manchester M1 7DN, United Kingdom
| | - Perdita E Barran
- School of Chemistry, University of Manchester, Manchester Institute of Biotechnology, 131 Princess Street, Manchester M1 7DN, United Kingdom
| |
Collapse
|
48
|
Wen X, Liu C, Ghislain L, Tovar K, Shah V, Stout SJ, Cifelli S, Satapati S, O’Donnell G, Sheth PR, Wildey MJ, Datwani SS, Covey TR, Bateman KP, McLaren DG. Direct Analysis from Phase-Separated Liquid Samples using ADE-OPI-MS: Applicability to High-Throughput Screening for Inhibitors of Diacylglycerol Acyltransferase 2. Anal Chem 2021; 93:6071-6079. [DOI: 10.1021/acs.analchem.0c04312] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Xiujuan Wen
- Merck & Company, Incorporated, 2000 Galloping Hill Road, Kenilworth, New Jersey 07033, United States
| | - Chang Liu
- SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4 V8, Canada
| | - Lucien Ghislain
- Beckman Coulter Life Sciences Incorporated, 170 Rose Orchard Way, San Jose, California 95134, United States
| | - Kiersten Tovar
- Merck & Company, Incorporated, 2000 Galloping Hill Road, Kenilworth, New Jersey 07033, United States
| | - Vinit Shah
- Merck & Company, Incorporated, 2000 Galloping Hill Road, Kenilworth, New Jersey 07033, United States
| | - Steven J. Stout
- Merck & Company, Incorporated, 2000 Galloping Hill Road, Kenilworth, New Jersey 07033, United States
| | - Steven Cifelli
- Merck & Company, Incorporated, 2000 Galloping Hill Road, Kenilworth, New Jersey 07033, United States
| | - Santhosh Satapati
- Merck & Company, Incorporated, 2000 Galloping Hill Road, Kenilworth, New Jersey 07033, United States
| | - Gregory O’Donnell
- Merck & Company, Incorporated, 2000 Galloping Hill Road, Kenilworth, New Jersey 07033, United States
| | - Payal R. Sheth
- Merck & Company, Incorporated, 2000 Galloping Hill Road, Kenilworth, New Jersey 07033, United States
| | - Mary Jo Wildey
- Merck & Company, Incorporated, 2000 Galloping Hill Road, Kenilworth, New Jersey 07033, United States
| | - Sammy S. Datwani
- Beckman Coulter Life Sciences Incorporated, 170 Rose Orchard Way, San Jose, California 95134, United States
| | - Thomas R. Covey
- SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4 V8, Canada
| | - Kevin P. Bateman
- Merck & Company, Incorporated, 2000 Galloping Hill Road, Kenilworth, New Jersey 07033, United States
| | - David G. McLaren
- Merck & Company, Incorporated, 2000 Galloping Hill Road, Kenilworth, New Jersey 07033, United States
| |
Collapse
|
49
|
Rankin‐Turner S, Heaney LM. Applications of ambient ionization mass spectrometry in 2020: An annual review. ANALYTICAL SCIENCE ADVANCES 2021; 2:193-212. [PMID: 38716454 PMCID: PMC10989608 DOI: 10.1002/ansa.202000135] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 01/22/2021] [Accepted: 01/25/2021] [Indexed: 06/26/2024]
Abstract
Recent developments in mass spectrometry (MS) analyses have seen a concerted effort to reduce the complexity of analytical workflows through the simplification (or removal) of sample preparation and the shortening of run-to-run analysis times. Ambient ionization mass spectrometry (AIMS) is an exemplar MS-based technology that has swiftly developed into a popular and powerful tool in analytical science. This increase in interest and demonstrable applications is down to its capacity to enable the rapid analysis of a diverse range of samples, typically in their native state or following a minimalistic sample preparation approach. The field of AIMS is constantly improving and expanding, with developments of powerful and novel techniques, improvements to existing instrumentation, and exciting new applications added with each year that passes. This annual review provides an overview of applications of AIMS techniques over the past year (2020), with a particular focus on the application of AIMS in a number of key fields of research including biomedical sciences, forensics and security, food sciences, the environment, and chemical synthesis. Novel ambient ionization techniques are introduced, including picolitre pressure-probe electrospray ionization and fiber spray ionization, in addition to modifications and improvements to existing techniques such as hand-held devices for ease of use, and USB-powered ion sources for on-site analysis. In all, the information provided in this review supports the view that AIMS has become a leading approach in MS-based analyses and that improvements to existing methods, alongside the development of novel approaches, will continue across the foreseeable future.
Collapse
Affiliation(s)
- Stephanie Rankin‐Turner
- W. Harry Feinstone Department of Molecular Microbiology and Immunology, Johns Hopkins Bloomberg School of Public HealthJohns Hopkins UniversityBaltimoreMarylandUSA
| | - Liam M. Heaney
- School of Sport, Exercise and Health SciencesLoughborough UniversityLoughboroughLeicestershireUK
| |
Collapse
|
50
|
Vervoort N, Goossens K, Baeten M, Chen Q. Recent advances in analytical techniques for high throughput experimentation. ANALYTICAL SCIENCE ADVANCES 2021; 2:109-127. [PMID: 38716456 PMCID: PMC10989611 DOI: 10.1002/ansa.202000155] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/22/2020] [Revised: 12/18/2020] [Accepted: 12/21/2020] [Indexed: 11/17/2024]
Abstract
High throughput experimentation is a growing and evolving field that allows to execute dozens to several thousands of experiments per day with relatively limited resources. Through miniaturization, typically a high degree of automation and the use of digital data tools, many parallel reactions or experiments at a time can be run in such workflows. High throughput experimentation also requires fast analytical techniques capable of generating critically important analytical data in line with the increased rate of experimentation. As traditional techniques usually do not deliver the speed required, some unique approaches are required to enable workflows to function as designed. This review covers the recent developments (2019-2020) in this field and was intended to give a comprehensive overview of the current "state-of-the-art."
Collapse
Affiliation(s)
- Nico Vervoort
- Chemical Process R&DProcess Analytical ResearchJanssen R&DBeerseBelgium
| | - Karel Goossens
- Chemical Process R&DProcess Analytical ResearchJanssen R&DBeerseBelgium
| | - Mattijs Baeten
- Chemical Process R&DProcess Analytical ResearchJanssen R&DBeerseBelgium
| | - Qinghao Chen
- Chemical Process R&DHigh Throughput ExperimentationJanssen R&DBeerseBelgium
| |
Collapse
|