1
|
Serrage HJ, Eling CJ, Alves PU, Xie E, McBain AJ, Dawson MD, O’Neill C, Laurand N. Spectral characterization of a blue light-emitting micro-LED platform on skin-associated microbial chromophores. BIOMEDICAL OPTICS EXPRESS 2024; 15:3200-3215. [PMID: 38855662 PMCID: PMC11161378 DOI: 10.1364/boe.522867] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/01/2024] [Revised: 04/04/2024] [Accepted: 04/04/2024] [Indexed: 06/11/2024]
Abstract
The therapeutic application of blue light (380 - 500nm) has garnered considerable attention in recent years as it offers a non-invasive approach for the management of prevalent skin conditions including acne vulgaris and atopic dermatitis. These conditions are often characterised by an imbalance in the microbial communities that colonise our skin, termed the skin microbiome. In conditions including acne vulgaris, blue light is thought to address this imbalance through the selective photoexcitation of microbial species expressing wavelength-specific chromophores, differentially affecting skin commensals and thus altering the relative species composition. However, the abundance and diversity of these chromophores across the skin microbiota remains poorly understood. Similarly, devices utilised for studies are often bulky and poorly characterised which if translated to therapy could result in reduced patient compliance. Here, we present a clinically viable micro-LED illumination platform with peak emission 450 nm (17 nm FWHM) and adjustable irradiance output to a maximum 0.55 ± 0.01 W/cm2, dependent upon the concentration of titanium dioxide nanoparticles applied to an accompanying flexible light extraction substrate. Utilising spectrometry approaches, we characterised the abundance of prospective blue light chromophores across skin commensal bacteria isolated from healthy volunteers. Of the strains surveyed 62.5% exhibited absorption peaks within the blue light spectrum, evidencing expression of carotenoid pigments (18.8%, 420-483 nm; Micrococcus luteus, Kocuria spp.), porphyrins (12.5%, 402-413 nm; Cutibacterium spp.) and potential flavins (31.2%, 420-425 nm; Staphylococcus and Dermacoccus spp.). We also present evidence of the capacity of these species to diminish irradiance output when combined with the micro-LED platform and in turn how exposure to low-dose blue light causes shifts in observed absorbance spectra peaks. Collectively these findings highlight a crucial deficit in understanding how microbial chromophores might shape response to blue light and in turn evidence of a micro-LED illumination platform with potential for clinical applications.
Collapse
Affiliation(s)
- Hannah J. Serrage
- School of Biological Sciences, Faculty of Biology Medicine and Health, The University of Manchester, UK
| | - Charlotte J. Eling
- Institute of Photonics, Department of Physics, SUPA, University of Strathclyde, UK
| | - Pedro U. Alves
- Institute of Photonics, Department of Physics, SUPA, University of Strathclyde, UK
| | - Enyuan Xie
- Institute of Photonics, Department of Physics, SUPA, University of Strathclyde, UK
| | - Andrew J. McBain
- Division of Pharmacy and Optometry, School of Health Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, UK
| | - Martin D. Dawson
- Institute of Photonics, Department of Physics, SUPA, University of Strathclyde, UK
| | - Catherine O’Neill
- School of Biological Sciences, Faculty of Biology Medicine and Health, The University of Manchester, UK
| | - Nicolas Laurand
- Institute of Photonics, Department of Physics, SUPA, University of Strathclyde, UK
| |
Collapse
|
2
|
Júlio A, Caparica R, Costa Lima SA, Fernandes AS, Rosado C, Prazeres DMF, Reis S, Santos de Almeida T, Fonte P. Ionic Liquid-Polymer Nanoparticle Hybrid Systems as New Tools to Deliver Poorly Soluble Drugs. NANOMATERIALS (BASEL, SWITZERLAND) 2019; 9:E1148. [PMID: 31405123 PMCID: PMC6723845 DOI: 10.3390/nano9081148] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/04/2019] [Revised: 08/06/2019] [Accepted: 08/07/2019] [Indexed: 01/10/2023]
Abstract
The use of functional excipients such as ionic liquids (ILs) and the encapsulation of drugs into nanocarriers are useful strategies to overcome poor drug solubility. The aim of this work was to evaluate the potential of IL-polymer nanoparticle hybrid systems as tools to deliver poorly soluble drugs. These systems were obtained using a methodology previously developed by our group and improved herein to produce IL-polymer nanoparticle hybrid systems. Two different choline-based ILs and poly (lactic-co-glycolic acid) (PLGA) 50:50 or PLGA 75:25 were used to load rutin into the delivery system. The resulting rutin-loaded IL-polymer nanoparticle hybrid systems presented a diameter of 250-300 nm, with a low polydispersity index and a zeta potential of about -40 mV. The drug association efficiency ranged from 51% to 76%, which represents a good achievement considering the poor solubility of rutin. No significant particle aggregation was obtained upon freeze-drying. The presence of the IL in the nanosystem does not affect its sustained release properties, achieving about 85% of rutin released after 72 h. The cytotoxicity studies showed that the delivery system was not toxic to HaCat cells. Our findings may open a new paradigm on the therapy improvement of diseases treated with poorly soluble drugs.
Collapse
Affiliation(s)
- Ana Júlio
- CBIOS-Universidade Lusófona Research Center for Biosciences & Health Technologies, Campo Grande 376, 1749-024 Lisboa, Portugal
- Department of Biomedical Sciences, University of Alcalá, Ctra. Madrid-Barcelona Km. 33.600, 28871 Alcalá de Henares, Madrid, Spain
| | - Rita Caparica
- CBIOS-Universidade Lusófona Research Center for Biosciences & Health Technologies, Campo Grande 376, 1749-024 Lisboa, Portugal
- Department of Biomedical Sciences, University of Alcalá, Ctra. Madrid-Barcelona Km. 33.600, 28871 Alcalá de Henares, Madrid, Spain
| | - Sofia A Costa Lima
- LAQV, REQUIMTE, Department of Chemical Sciences-Applied Chemistry Lab, Faculty of Pharmacy, University of Porto, Rua de Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal
| | - Ana Sofia Fernandes
- CBIOS-Universidade Lusófona Research Center for Biosciences & Health Technologies, Campo Grande 376, 1749-024 Lisboa, Portugal
| | - Catarina Rosado
- CBIOS-Universidade Lusófona Research Center for Biosciences & Health Technologies, Campo Grande 376, 1749-024 Lisboa, Portugal
| | - Duarte M F Prazeres
- iBB-Institute for Bioengineering and Biosciences, Department of Bioengineering, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal
| | - Salette Reis
- LAQV, REQUIMTE, Department of Chemical Sciences-Applied Chemistry Lab, Faculty of Pharmacy, University of Porto, Rua de Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal
| | - Tânia Santos de Almeida
- CBIOS-Universidade Lusófona Research Center for Biosciences & Health Technologies, Campo Grande 376, 1749-024 Lisboa, Portugal.
| | - Pedro Fonte
- CBIOS-Universidade Lusófona Research Center for Biosciences & Health Technologies, Campo Grande 376, 1749-024 Lisboa, Portugal.
- LAQV, REQUIMTE, Department of Chemical Sciences-Applied Chemistry Lab, Faculty of Pharmacy, University of Porto, Rua de Jorge Viterbo Ferreira, 228, 4050-313 Porto, Portugal.
- iBB-Institute for Bioengineering and Biosciences, Department of Bioengineering, Instituto Superior Técnico, Universidade de Lisboa, 1049-001 Lisboa, Portugal.
| |
Collapse
|
3
|
Zhang Z, Wen Y, Du J, Yu Y, Liu S, Wu X, Zhao H. Effects of mechanical stretch on the functions of BK and L-type Ca 2+ channels in vascular smooth muscle cells. J Biomech 2017; 67:18-23. [PMID: 29248193 DOI: 10.1016/j.jbiomech.2017.11.015] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2017] [Revised: 09/14/2017] [Accepted: 11/16/2017] [Indexed: 11/18/2022]
Abstract
It is well recognized that pathologically increased mechanical stretch plays a critical role in vascular remodeling during hypertension. However, how the stretch modulates the functions of ion channels of vascular smooth muscle cells (VSMCs) remains to be elucidated. Here, we demonstrated the effects of mechanical stretch on the activity of large conductance calcium, voltage-activated potassium (BK) and L-type Ca2+ channels. In comparison with 5% stretch (physiological), 15% stretch (pathological) upregulated the current density of L-type Ca2+ and BK channels as well as the frequency and amplitude of calcium oscillation in VSMCs. 15% stretch also increased the open probability and mean open time of the BK channel compared with 5% stretch. BK and L-type Ca2+ channels participated in the mechanical stretch-modulated calcium oscillation. Our results suggested that during hypertension, pathological stretch altered the activity of BK and L-type Ca2+ channels and manipulated the calcium oscillation of VSMCs.
Collapse
Affiliation(s)
- Zhiguo Zhang
- Institute of Biomedical Engineering and Health Sciences, Changzhou University, Changzhou, Jiangsu 213164, China
| | - Yuqiao Wen
- School of Automation and Information Engineering, Sichuan University of Science and Engineering, Zigong 614000, China
| | - Jing Du
- Institute of Biomechanics and Medical Engineering, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China
| | - Yang Yu
- Institute of Biomechanics and Medical Engineering, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China
| | - Sisi Liu
- Institute of Biomechanics and Medical Engineering, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China
| | - Xiaoan Wu
- Institute of Biomechanics and Medical Engineering, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China
| | - Hucheng Zhao
- School of Automation and Information Engineering, Sichuan University of Science and Engineering, Zigong 614000, China; Institute of Biomechanics and Medical Engineering, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China.
| |
Collapse
|
4
|
Wan XJ, Zhao HC, Zhang P, Huo B, Shen BR, Yan ZQ, Qi YX, Jiang ZL. Involvement of BK channel in differentiation of vascular smooth muscle cells induced by mechanical stretch. Int J Biochem Cell Biol 2015; 59:21-9. [DOI: 10.1016/j.biocel.2014.11.011] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2014] [Revised: 11/13/2014] [Accepted: 11/25/2014] [Indexed: 12/26/2022]
|
5
|
Gamerdinger K, Wernet F, Smudde E, Schneider M, Guttmann J, Schumann S. Mechanical load and mechanical integrity of lung cells - experimental mechanostimulation of epithelial cell- and fibroblast-monolayers. J Mech Behav Biomed Mater 2014; 40:201-209. [PMID: 25241284 DOI: 10.1016/j.jmbbm.2014.08.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2014] [Revised: 08/10/2014] [Accepted: 08/11/2014] [Indexed: 11/26/2022]
Abstract
Experimental mechanostimulation of soft biologic tissue is widely used to investigate cellular responses to mechanical stress or strain. Reactions on mechanostimulation are investigated in terms of morphological changes, inflammatory responses and apoptosis/necrosis induction on a cellular level. In this context, the analysis of the mechanical characteristics of cell-layers might allow to indicate patho-physiological changes in the cell-cell contacts. Recently, we described a device for experimental mechanostimulation that allows simultaneous measurement of the mechanical characteristics of cell-monolayers. Here, we investigated how cultivated lung epithelial cell- and fibroblast-monolayers behave mechanically under different amplitudes of biaxial distension. The cell monolayers were sinusoidally deflected to 5%, 10% or 20% surface gain and their mechanical properties during mechanostimulation were analyzed. With increasing stimulation amplitudes more pronounced reductions of cell junctions were observed. These findings were accompanied by a substantial loss of monolayer rigidity. Pulmonary fibroblast monolayers were initially stiffer but were stronger effected by the mechanostimulation compared to epithelial cell-monolayers. We conclude that, according to their biomechanical function within the pulmonary tissue, epithelial cells and fibroblasts differ with respect to their mechanical characteristics and tolerance of mechanical load.
Collapse
Affiliation(s)
- Katharina Gamerdinger
- Department of Anesthesiology and Intensive Care Medicine, Division of Experimental Anesthesiology, University Medical Center Freiburg, Hugstetter Straße 55, D-79106 Freiburg, Germany.
| | - Florian Wernet
- Department of Anesthesiology and Intensive Care Medicine, Division of Experimental Anesthesiology, University Medical Center Freiburg, Hugstetter Straße 55, D-79106 Freiburg, Germany
| | - Eva Smudde
- Department of Anesthesiology and Intensive Care Medicine, Division of Experimental Anesthesiology, University Medical Center Freiburg, Hugstetter Straße 55, D-79106 Freiburg, Germany
| | - Matthias Schneider
- Department of Anesthesiology and Intensive Care Medicine, Division of Experimental Anesthesiology, University Medical Center Freiburg, Hugstetter Straße 55, D-79106 Freiburg, Germany
| | - Josef Guttmann
- Department of Anesthesiology and Intensive Care Medicine, Division of Experimental Anesthesiology, University Medical Center Freiburg, Hugstetter Straße 55, D-79106 Freiburg, Germany
| | - Stefan Schumann
- Department of Anesthesiology and Intensive Care Medicine, Division of Experimental Anesthesiology, University Medical Center Freiburg, Hugstetter Straße 55, D-79106 Freiburg, Germany
| |
Collapse
|
6
|
Endoscopic Imaging to Assess Alveolar Mechanics During Quasi-static and Dynamic Ventilatory Conditions in Rats With Noninjured and Injured Lungs*. Crit Care Med 2013; 41:1286-95. [DOI: 10.1097/ccm.0b013e31827712fa] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
7
|
Dassow C, Armbruster C, Friedrich C, Smudde E, Guttmann J, Schumann S. A method to measure mechanical properties of pulmonary epithelial cell layers. J Biomed Mater Res B Appl Biomater 2013; 101:1164-71. [PMID: 23564730 DOI: 10.1002/jbm.b.32926] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2012] [Revised: 01/16/2013] [Accepted: 02/11/2013] [Indexed: 01/09/2023]
Abstract
The lung has a huge inner alveolar surface composed of epithelial cell layers. The knowledge about mechanical properties of lung epithelia is helpful to understand the complex lung mechanics and biomechanical interactions. Methods have been developed to determine mechanical indices (e.g., tissue elasticity) which are both very complex and in need of costly equipment. Therefore, in this study, a mechanostimulator is presented to dynamically stimulate lung epithelial cell monolayers in order to determine their mechanical properties based on a simple mathematical model. First, the method was evaluated by comparison to classical tensile testing using silicone membranes as substitute for biological tissue. Second, human pulmonary epithelial cells (A549 cell line) were grown on flexible silicone membranes and stretched at a defined magnitude. Equal secant moduli were determined in the mechanostimulator and in a conventional tension testing machine (0.49 ± 0.05 MPa and 0.51 ± 0.03 MPa, respectively). The elasticity of the cell monolayer could be calculated by the volume-pressure relationship resulting from inflation of the membrane-cell construct. The secant modulus of the A549 cell layer was calculated as 0.04 ± 0.008 MPa. These findings suggest that the mechanostimulator may represent an adequate device to determine mechanical properties of cell layers.
Collapse
Affiliation(s)
- Constanze Dassow
- Department of Experimental Anaesthesiology, University Medical Centre, Hugstetter Straße 55, 79106 Freiburg, Germany
| | | | | | | | | | | |
Collapse
|
8
|
Nguyen BNB, Chetta J, Shah SB. A Novel Technology for Simultaneous Tensile Loading and High-Resolution Imaging of Cells. Cell Mol Bioeng 2012. [DOI: 10.1007/s12195-012-0245-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
|
9
|
Schwenninger D, Runck H, Schumann S, Haberstroh J, Guttmann J. Locally measured shear moduli of pulmonary tissue and global lung mechanics in mechanically ventilated rats. J Appl Physiol (1985) 2012; 113:273-80. [PMID: 22628379 DOI: 10.1152/japplphysiol.01620.2011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
This study was aimed at measuring shear moduli in vivo in mechanically ventilated rats and comparing them to global lung mechanics. Wistar rats (n = 28) were anesthetized, tracheally intubated, and mechanically ventilated in supine position. The animals were randomly assigned to the healthy control or the lung injury group where lung injury was induced by bronchoalveolar lavage. The respiratory system elastance E(rs) was analyzed based on the single compartment resistance/elastance lung model using multiple linear regression analysis. The shear modulus (G) of alveolar parenchyma was studied using a newly developed endoscopic system with adjustable pressure at the tip that was designed to induce local mechanostimulation. The data analysis was then carried out with an inverse finite element method. G was determined at continuous positive airway pressure (CPAP) levels of 15, 17, 20, and 30 mbar. The resulting shear moduli of lungs in healthy animals increased from 3.3 ± 1.4 kPa at 15 mbar CPAP to 5.8 ± 2.4 kPa at 30 mbar CPAP (P = 0.012), whereas G was ~2.5 kPa at all CPAP levels for the lung-injured animals. Regression analysis showed a negative correlation between G and relative E(rs) in the control group (r = -0.73, P = 0.008 at CPAP = 20 mbar) and no significant correlation in the lung injury group. These results suggest that the locally measured G were inversely associated with the elastance of the respiratory system. Rejecting the study hypothesis the researchers concluded that low global respiratory system elastance is related to high local resistance against tissue deformation.
Collapse
Affiliation(s)
- David Schwenninger
- Division of Experimental Anaesthesiology, University Medical Center Freiburg, Hugstetter Strasse 55, Freiburg, Germany.
| | | | | | | | | |
Collapse
|
10
|
Armbruster C, Dassow C, Gamerdinger K, Schneider M, Sumkauskaite M, Guttmann J, Schumann S. Mechanostimulation, electrostimulation and force measurement in anin vitromodel of the isolated rat diaphragm. Physiol Meas 2011; 32:1899-912. [DOI: 10.1088/0967-3334/32/12/002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
11
|
Schwenninger D, Schumann S, Guttmann J. In vivo characterization of mechanical tissue properties of internal organs using endoscopic microscopy and inverse finite element analysis. J Biomech 2011; 44:487-93. [DOI: 10.1016/j.jbiomech.2010.09.019] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2010] [Revised: 09/03/2010] [Accepted: 09/15/2010] [Indexed: 11/28/2022]
|
12
|
Stress-strain relationship in pulmonary cells under bidirectional stretch application. Crit Care 2011. [PMCID: PMC3066868 DOI: 10.1186/cc9614] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
13
|
Dassow C, Wiechert L, Martin C, Schumann S, Müller-Newen G, Pack O, Guttmann J, Wall WA, Uhlig S. Biaxial distension of precision-cut lung slices. J Appl Physiol (1985) 2010; 108:713-21. [PMID: 20075265 DOI: 10.1152/japplphysiol.00229.2009] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The mechanical forces acting on lung parenchyma during (mechanical) ventilation and its (patho)physiological consequences are currently under intense scrutiny. Several in vivo and cell culture models have been developed to study the pulmonary responses to mechanical stretch. While providing extremely useful information, these models do also suffer from limitations in being either too complex for detailed mechanical or mechanistic studies, or in being devoid of the full complexity present in vivo (e.g., different cell types and interstitial matrix). Therefore in the present study it was our aim to develop a new model, based on the biaxial stretching of precision-cut lung slices (PCLS). Single PCLS were mounted on a thin and flexible carrier membrane of polydimethylsiloxane (PDMS) in a bioreactor, and the membrane was stretched by applying varying pressures under static conditions. Distension of the membrane-PCLS construct was modeled via finite element simulation. According to this analysis, lung tissue was stretched by up to 38% in the latitudinal and by up to 44% in the longitudinal direction, resulting in alveolar distension similar to what has been described in intact lungs. Stretch for 5 min led to increased cellular calcium levels. Lung slices were stretched dynamically with a frequency of 15/min for 4 h without causing cell injury {3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide (MTT) test; live/dead straining}. These findings suggest that stretching of PCLS on PDMS-membranes may represent a useful model to investigate lung stretch in intact lung tissue in vitro for several hours.
Collapse
Affiliation(s)
- C Dassow
- Institute of Pharmacology and Toxicology, Medical Faculty, RWTH Aachen University, Wendlingweg 2, 52074 Aachen, Germany
| | | | | | | | | | | | | | | | | |
Collapse
|