1
|
Vu BV, Lei R, Mohan C, Kourentzi K, Willson RC. Flash Characterization of Smartphones Used in Point-of-Care Diagnostics. BIOSENSORS 2022; 12:1060. [PMID: 36551027 PMCID: PMC9776052 DOI: 10.3390/bios12121060] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2022] [Revised: 11/03/2022] [Accepted: 11/15/2022] [Indexed: 06/17/2023]
Abstract
Rapidly growing interest in smartphone cameras as the basis of point-of-need diagnostic and bioanalytical technologies increases the importance of quantitative characterization of phone optical performance under real-world operating conditions. In the context of our development of lateral-flow immunoassays based on phosphorescent nanoparticles, we have developed a suite of tools for characterizing the temporal and spectral profiles of smartphone torch and flash emissions, and their dependence on phone power state. In this work, these tools are described and documented to make them easily available to others, and demonstrated by application to characterization of Apple iPhone 5s, iPhone 6s, iPhone 8, iPhone XR, and Samsung Note8 flash performance as a function of time and wavelength, at a variety of power settings. Flash and torch intensity and duration vary with phone state and among phone models. Flash has high variability when the battery charge is below 10%, thus, smartphone-based Point-of-Care (POC) tests should only be performed at a battery level of at least 15%. Some output variations could substantially affect the results of assays that rely on the smartphone flash.
Collapse
Affiliation(s)
- Binh V. Vu
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX 77204, USA
| | - Rongwei Lei
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
| | - Chandra Mohan
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
| | - Katerina Kourentzi
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX 77204, USA
| | - Richard C. Willson
- William A. Brookshire Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX 77204, USA
- Department of Biomedical Engineering, University of Houston, Houston, TX 77204, USA
- Department of Biology and Biochemistry, University of Houston, Houston, TX 77204, USA
- Escuela de Medicina y Ciencias de la Salud ITESM, Monterrey 64710, NL, Mexico
| |
Collapse
|
2
|
Sajed S, Kolahdouz M, Sadeghi MA. Prediction of Arsenic Concentration in Water Samples Using Digital Imaging Colorimetry and Multi‐Variable Regression. ChemistrySelect 2022. [DOI: 10.1002/slct.202201376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Samira Sajed
- School of Electrical and Computer Engineering College of Engineering University of Tehran Tehran Iran
| | - Mohammadreza Kolahdouz
- School of Electrical and Computer Engineering College of Engineering University of Tehran Tehran Iran
| | - Mohammad Amin Sadeghi
- School of Electrical and Computer Engineering College of Engineering University of Tehran Tehran Iran
| |
Collapse
|
3
|
Zhang Y, Xue T, Cheng L, Wang J, Shen R, Zhang J. Smartphone-assisted colorimetric biosensor for on-site detection of Cr3+ ion analysis. Anal Chim Acta 2022; 1199:339603. [DOI: 10.1016/j.aca.2022.339603] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2021] [Revised: 02/10/2022] [Accepted: 02/11/2022] [Indexed: 11/27/2022]
|
4
|
Wu X, Pan J, Zhu X, Hong C, Hu A, Zhu C, Liu Y, Yang K, Zhu L. MS 2 device: smartphone-facilitated mobile nucleic acid analysis on microfluidic device. Analyst 2021; 146:3823-3833. [PMID: 34121097 DOI: 10.1039/d1an00367d] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Mobile sensing based on the integration of microfluidic devices and smartphones, so-called MS2 technology, has enabled many applications over recent years and continues to stimulate growing interest in both research communities and industries. In particular, MS2 technology has been proven to be able to be applied to molecular diagnostic analysis and can be implemented for basic research and clinical testing. However, the currently reported MS2-based nucleic acid analysis system has limited use in practical applications, because it is not integrated with quantitative PCR, multiplex PCR, and isothermal amplification functions, and lacks temperature control, image acquisition and real-time processing units with excellent performance. To provide a more universal and powerful platform, we here developed a novel MS2 device by integrating a thermocycler, a multi fluorescence detection unit, a PCR chip, an isothermal chip, and a smartphone. The MS2 device was approximately 325 mm (L) × 200 mm (W) × 200 mm (H) in volume and only 5 kg in weight, and showed an average power consumption of about 38.4 W. The entire nucleic acid amplification and analysis could be controlled through a self-made smartphone App. The maximum heating and cooling rates were 5 °C s-1 and 4 °C s-1, respectively. The entire PCR could be completed within 65 min. The temperature uniformity was less than 0.1 °C. Besides, the temperature stability over time (30 min) was within ±0.04 °C. Four optical channels were integrated (FAM, HEX, TAMRA, and ROX) on the MS2 device. In particular, the PCR-based detection sensitivity reached 1 copy per μL, and the amplification efficiency was calculated to be 106.8%. Besides, the MS2 device also was compatible with multiplex PCR and isothermal amplification. In short, the MS2 device showed performance consistent with that of traditional commercial equipment. Thus, the MS2 device provides an easy and integrated experimental platform for molecular diagnostic-related research and potential medical diagnostic applications.
Collapse
Affiliation(s)
- Xiaosong Wu
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China. and University of Science and Technology of China, No. 96, JinZhai Road Baohe District, Hefei 230026, PR China
| | - Jingyu Pan
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China.
| | - Xinchao Zhu
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China. and University of Science and Technology of China, No. 96, JinZhai Road Baohe District, Hefei 230026, PR China
| | - Chenggang Hong
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China.
| | - Anzhong Hu
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China.
| | - Cancan Zhu
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China.
| | - Yong Liu
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China.
| | - Ke Yang
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China.
| | - Ling Zhu
- Anhui Institute of Optics and Fine Mechanics, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China.
| |
Collapse
|
5
|
Yuan Z, Huang X, Wan P, Zhao C, Zhang Y, Zhang B, Wang J, Zhang H, Sang S. A cost-effective smartphone-based device for ankle-brachial index (ABI) detection. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 198:105790. [PMID: 33069974 DOI: 10.1016/j.cmpb.2020.105790] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Accepted: 10/05/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND AND OBJECTIVE Detectors of ankle-brachial index (ABI) are commonly used in cardiovascular patients who have high-risk levels of arteriosclerosis. Increased evidences suggest that patients with arteriosclerosis possess many risks of geriatric and chronic diseases. Meanwhile, new chronic treatments trend from the hospitals toward family and community health centers, but for arteriosclerosis cases have delivered benefits far below instrument costs. Compared to traditional devices based on cuff pressure, cuffless and non-invasive measures have wider application potential in home health care, especially in the case of physically-restricted or severely symptomatic patients. METHODS In this study, we developed a simple smartphone-based device for non-invasive ABI monitoring, which consists of four wireless cuffless limbs blood sensors. By identifying and tracking blood flow waveform, a multiparameter fusion (MPF) algorithm is used to estimate blood pressure and generate ABI value. An ARM-based chip STM32 has been adopted as the microcontroller. The ABI calculating program is embedded in C++ and executed by the processor. After generating data, ABI information can be delivered to the smartphone by using Bluetooth. Relying on mobile apps to visualize the data and display on the screen, doctors can monitor cardiovascular patients in real time and analyze the risk levels of arteriosclerosis online. RESULTS In this paper, the detection conducted by the classical Doppler equipment and prototype were recorded respectively. A statistical evaluation of the verification results obtained from 29 patients and 7 sub-health volunteers is given, which shows that our device can achieve 91.80% and 93.84% accuracy for patients and sub-health volunteers, respectively. In addition, the prototype can be performed stably for a continuous long time monitoring. CONCLUSIONS According to our studies, the accuracy of our device is sufficient for home medical and chronic disease monitoring within a certain time interval. The smartphone-based ABI device has several apparent advantages over traditional devices, such as portability, cost-effectiveness and energy-efficiency.
Collapse
Affiliation(s)
- Zhongyun Yuan
- MicroNano System Research Center, College of Information & Computer Engineering, Key Laboratory of Advanced Transducers and Intelligent Control System of Ministry of Education and Shanxi Province, Taiyuan University of Technology, Taiyuan 030024, China
| | - Xinru Huang
- MicroNano System Research Center, College of Information & Computer Engineering, Key Laboratory of Advanced Transducers and Intelligent Control System of Ministry of Education and Shanxi Province, Taiyuan University of Technology, Taiyuan 030024, China
| | - Pei Wan
- MicroNano System Research Center, College of Information & Computer Engineering, Key Laboratory of Advanced Transducers and Intelligent Control System of Ministry of Education and Shanxi Province, Taiyuan University of Technology, Taiyuan 030024, China
| | - Chun Zhao
- College of Information and Communication Engineering, Sungkyunkwan University, Suwon 440-746, Korea
| | - Yixia Zhang
- MicroNano System Research Center, College of Information & Computer Engineering, Key Laboratory of Advanced Transducers and Intelligent Control System of Ministry of Education and Shanxi Province, Taiyuan University of Technology, Taiyuan 030024, China
| | - Bo Zhang
- MicroNano System Research Center, College of Information & Computer Engineering, Key Laboratory of Advanced Transducers and Intelligent Control System of Ministry of Education and Shanxi Province, Taiyuan University of Technology, Taiyuan 030024, China
| | - Jianming Wang
- General Hospital of TISCO, North Street, Xinghualing District, Taiyuan 030024, China
| | - Hongpeng Zhang
- Department of Vascular Surgery, Chinese PLA General Hospital, Beijing 100853, China.
| | - Shengbo Sang
- MicroNano System Research Center, College of Information & Computer Engineering, Key Laboratory of Advanced Transducers and Intelligent Control System of Ministry of Education and Shanxi Province, Taiyuan University of Technology, Taiyuan 030024, China.
| |
Collapse
|
6
|
Son J, Mandracchia B, Jia S. Miniaturized modular-array fluorescence microscopy. BIOMEDICAL OPTICS EXPRESS 2020; 11:7221-7235. [PMID: 33408992 PMCID: PMC7747904 DOI: 10.1364/boe.410605] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Revised: 11/10/2020] [Accepted: 11/12/2020] [Indexed: 05/20/2023]
Abstract
Fluorescence live-cell imaging allows for continuous interrogation of cellular behaviors, and the recent development of portable live-cell imaging platforms has rapidly transformed conventional schemes with high adaptability, cost-effective functionalities and easy accessibility to cell-based assays. However, broader applications remain restrictive due to compatibility with conventional cell culture workflow and biochemical sensors, accessibility to up-right physiological imaging, or parallelization of data acquisition. Here, we introduce miniaturized modular-array fluorescence microscopy (MAM) for compact live-cell imaging in flexible formats. We advance the current miniscopy technology to devise an up-right modular architecture, each combining a gradient-index (GRIN) objective and individually-addressed illumination and acquisition components. Parallelization of an array of such modular devices allows for multi-site data acquisition in situ using conventional off-the-shelf cell chambers. Compared with existing methods, the device offers a high fluorescence sensitivity and efficiency, exquisite spatiotemporal resolution (∼3 µm and up to 60 Hz), a configuration compatible with conventional cell culture assays and physiological imaging, and an effective parallelization of data acquisition. The system has been demonstrated using various calibration and biological samples and experimental conditions, representing a promising solution to time-lapse in situ single-cell imaging and analysis.
Collapse
|
7
|
Chen W, Yao Y, Chen T, Shen W, Tang S, Lee HK. Application of smartphone-based spectroscopy to biosample analysis: A review. Biosens Bioelectron 2020; 172:112788. [PMID: 33157407 DOI: 10.1016/j.bios.2020.112788] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 10/05/2020] [Accepted: 10/30/2020] [Indexed: 12/18/2022]
Abstract
The emergence of the smartphones has brought extensive changes to our lifestyles, from communicating with one another, to shopping and enjoyment of entertainment, and from studying to functioning at the workplace (and in the field). At the same time, this portable device has also provided new possibilities in scientific research and applications. Based on the growing awareness of good health management, researchers have coupled health monitoring to smartphone sensing technologies. Along the way, there have been developed a variety of smartphone-based optical detection platforms for analyzing biological samples, including standalone smartphone units and integrated smartphone sensing systems. In this review, we outline the applications of smartphone-based optical sensors for biosamples. These applications focus mainly on three aspects: Microscopic imaging sensing, colorimetric sensing and luminescence sensing. We also discuss briefly some limitations of the current state of smartphone-based spectroscopy and present prospects of the future applicability of smartphone sensors.
Collapse
Affiliation(s)
- Wenhui Chen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Yao Yao
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Tianyu Chen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Wei Shen
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China
| | - Sheng Tang
- School of Environmental and Chemical Engineering, Jiangsu University of Science and Technology, Zhenjiang, 212003, Jiangsu Province, China.
| | - Hian Kee Lee
- Department of Chemistry, National University of Singapore, 3 Science Drive 3, Singapore, 117543, Singapore; National University of Singapore Environmental Research Institute, T-Lab Building #02-01, 5A Engineering Drive 1, Singapore, 117411, Singapore; Tropical Marine Science Institute, National University of Singapore, S2S Building, 18 Kent Ridge Road, Singapore, 119227, Singapore.
| |
Collapse
|
8
|
Spence A, Bangay S. Side-Channel Sensing: Exploiting Side-Channels to Extract Information for Medical Diagnostics and Monitoring. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE-JTEHM 2020; 8:4900213. [PMID: 33094036 PMCID: PMC7571867 DOI: 10.1109/jtehm.2020.3028996] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Revised: 08/09/2020] [Accepted: 09/27/2020] [Indexed: 11/24/2022]
Abstract
Information within systems can be extracted through side-channels; unintended communication channels that leak information. The concept of side-channel sensing is explored, in which sensor data is analysed in non-trivial ways to recover subtle, hidden or unexpected information. Practical examples of side-channel sensing are well known in domains such as cybersecurity (CYB), but are not formally recognised within the domain of medical diagnostics and monitoring (MDM). This article reviews side-channel usage within CYB and MDM, identifying techniques and methodologies applicable to both domains. We establish a systematic structure for the use of side-channel sensing in MDM that is comparable to existing structures in CYB, and promote cross-domain transferability of knowledge, mindsets, and techniques.
Collapse
Affiliation(s)
- Aaron Spence
- School of Information TechnologyDeakin UniversityGeelongVIC3216Australia
| | - Shaun Bangay
- School of Information TechnologyDeakin UniversityGeelongVIC3216Australia
| |
Collapse
|
9
|
Abstract
Microscopes play an important role in the diagnosis of microorganisms and pathological lesions in ophthalmology guiding us to the appropriate management. The current trend of collecting samples and examination is mostly laboratory-based which consume time, labor, and are costly. Smartphones are being used in different fields of ophthalmology with great ubiquity. The good quality photographs obtained by smartphones along with the ease of mobility has made it possible to warrant its use in the microscopic world. This article describes a simple novel technique of preparing an intraocular lens system which can be used in conjunction with a smartphone to detect microorganisms and pathological lesions.
Collapse
Affiliation(s)
- Prithvi Chandrakanth
- General Ophthalmology, Dr. Chandrakanth Malabar Nethralaya, Kozhikode, Kerala, India
| | - K S Chandrakanth
- General Ophthalmology, Dr. Chandrakanth Malabar Nethralaya, Kozhikode, Kerala, India
| |
Collapse
|
10
|
Niu L, Liu X, Ma Z, Yin Y, Sun L, Yang L, Zheng Y. Fungal keratitis: Pathogenesis, diagnosis and prevention. Microb Pathog 2020; 138:103802. [PMID: 31626916 DOI: 10.1016/j.micpath.2019.103802] [Citation(s) in RCA: 85] [Impact Index Per Article: 17.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 10/12/2019] [Accepted: 10/12/2019] [Indexed: 02/08/2023]
Abstract
As a kind of serious, potentially sight-threatening corneal infections with poor prognosis, fungal keratitis can bring a heavy economic burden to patients and seriously affect the quality of life, especially those in developing countries where fungal keratitis is more prevalent. Typical clinical features include immune rings, satellite lesions, pseudopods, hypha moss, hypopyon and endothelial plaques. The ideal therapeutic effects could not be achieved by current treatments for many reasons. Therefore, under the current status, understanding the pathogenesis, early diagnosis and prevention strategies might be of great importance. Here, in this review, we discuss the recent progresses that may advance our understanding of pathogenesis, early diagnosis and prevention of fungal keratitis.
Collapse
Affiliation(s)
- Lingzhi Niu
- Eye Center, The Second Hospital of Jilin University, Changchun 130041, China
| | - Xin Liu
- Eye Center, The Second Hospital of Jilin University, Changchun 130041, China
| | - Zhiming Ma
- Department of Gastrointestinal Nutrition and Hernia Surgery, The Second Hospital of Jilin University, Changchun 130041, China
| | - Yuan Yin
- Eye Center, The Second Hospital of Jilin University, Changchun 130041, China
| | - Lixia Sun
- Department of Ophthalmology, Yanbian University Affiliated Hospital, Yanbian University, Yanji, 133000, China
| | - Longfei Yang
- Jilin Provincial Key Laboratory on Molecular and Chemical Genetics, The Second Hospital of Jilin University, Changchun 130041, China.
| | - Yajuan Zheng
- Eye Center, The Second Hospital of Jilin University, Changchun 130041, China.
| |
Collapse
|
11
|
Dai B, Jiao Z, Zheng L, Bachman H, Fu Y, Wan X, Zhang Y, Huang Y, Han X, Zhao C, Huang TJ, Zhuang S, Zhang D. Colour compound lenses for a portable fluorescence microscope. LIGHT, SCIENCE & APPLICATIONS 2019; 8:75. [PMID: 31645921 PMCID: PMC6804733 DOI: 10.1038/s41377-019-0187-1] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 07/11/2019] [Accepted: 07/31/2019] [Indexed: 05/25/2023]
Abstract
In this article, we demonstrated a handheld smartphone fluorescence microscope (HSFM) that integrates dual-functional polymer lenses with a smartphone. The HSFM consists of a smartphone, a field-portable illumination source, and a dual-functional polymer lens that performs both optical imaging and filtering. Therefore, compared with the existing smartphone fluorescence microscope, the HSFM does not need any additional optical filters. Although fluorescence imaging has traditionally played an indispensable role in biomedical and clinical applications due to its high specificity and sensitivity for detecting cells, proteins, DNAs/RNAs, etc., the bulky elements of conventional fluorescence microscopes make them inconvenient for use in point-of-care diagnosis. The HSFM demonstrated in this article solves this problem by providing a multifunctional, miniature, small-form-factor fluorescence module. This multifunctional fluorescence module can be seamlessly attached to any smartphone camera for both bright-field and fluorescence imaging at cellular-scale resolutions without the use of additional bulky lenses/filters; in fact, the HSFM achieves magnification and light filtration using a single lens. Cell and tissue observation, cell counting, plasmid transfection evaluation, and superoxide production analysis were performed using this device. Notably, this lens system has the unique capability of functioning with numerous smartphones, irrespective of the smartphone model and the camera technology housed within each device. As such, this HSFM has the potential to pave the way for real-time point-of-care diagnosis and opens up countless possibilities for personalized medicine.
Collapse
Affiliation(s)
- Bo Dai
- Engineering Research Center of Optical Instrument and System, the Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, 200093 Shanghai, China
| | - Ziao Jiao
- Engineering Research Center of Optical Instrument and System, the Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, 200093 Shanghai, China
| | - Lulu Zheng
- Engineering Research Center of Optical Instrument and System, the Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, 200093 Shanghai, China
| | - Hunter Bachman
- Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27709 USA
| | - Yongfeng Fu
- Department of Medical Microbiology and Parasitology, School of Basic Medical Sciences, Fudan University, 200032 Shanghai, China
| | - Xinjun Wan
- Engineering Research Center of Optical Instrument and System, the Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, 200093 Shanghai, China
| | - Yule Zhang
- Engineering Research Center of Optical Instrument and System, the Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, 200093 Shanghai, China
| | - Yu Huang
- Engineering Research Center of Optical Instrument and System, the Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, 200093 Shanghai, China
| | - Xiaodian Han
- Department of Laboratory Medicine, Shanghai Cancer Center, Fudan University, 200032 Shanghai, China
| | - Chenglong Zhao
- Department of Physics, University of Dayton, Dayton, OH 45469 USA
- Department of Electro-Optics and Photonics, University of Dayton, Dayton, OH 45469 USA
| | - Tony Jun Huang
- Department of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27709 USA
| | - Songlin Zhuang
- Engineering Research Center of Optical Instrument and System, the Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, 200093 Shanghai, China
| | - Dawei Zhang
- Engineering Research Center of Optical Instrument and System, the Ministry of Education, Shanghai Key Laboratory of Modern Optical System, University of Shanghai for Science and Technology, 200093 Shanghai, China
| |
Collapse
|
12
|
Yang K, Wu J, Santos S, Liu Y, Zhu L, Lin F. Recent development of portable imaging platforms for cell-based assays. Biosens Bioelectron 2019; 124-125:150-160. [DOI: 10.1016/j.bios.2018.10.024] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 10/06/2018] [Accepted: 10/13/2018] [Indexed: 12/22/2022]
|
13
|
R SK, Kumar SKA, Vijayakrishna K, Sivaramakrishna A, Brahmmananda Rao CVS, Sivaraman N, Sahoo SK. Development of the Smartphone-Assisted Colorimetric Detection of Thorium by Using New Schiff’s Base and Its Applications to Real Time Samples. Inorg Chem 2018; 57:15270-15279. [DOI: 10.1021/acs.inorgchem.8b02564] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
Affiliation(s)
- Selva Kumar R
- Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology, Vellore 632014, Tamil Nadu, India
| | - S. K. Ashok Kumar
- Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology, Vellore 632014, Tamil Nadu, India
| | - Kari Vijayakrishna
- Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology, Vellore 632014, Tamil Nadu, India
| | - Akella Sivaramakrishna
- Department of Chemistry, School of Advanced Sciences, Vellore Institute of Technology, Vellore 632014, Tamil Nadu, India
| | - C. V. S. Brahmmananda Rao
- Indira Gandhi Centre for Atomic Research, Homi Bhabha National Institute, Kalpakkam 603102, Tamil Nadu, India
| | - N. Sivaraman
- Indira Gandhi Centre for Atomic Research, Homi Bhabha National Institute, Kalpakkam 603102, Tamil Nadu, India
| | - Suban K. Sahoo
- Department of Applied Chemistry, S. V. National Institute Technology, Surat 395007, Gujarat, India
| |
Collapse
|
14
|
Smartphone-based pathogen diagnosis in urinary sepsis patients. EBioMedicine 2018; 36:73-82. [PMID: 30245056 PMCID: PMC6197494 DOI: 10.1016/j.ebiom.2018.09.001] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2018] [Revised: 09/01/2018] [Accepted: 09/03/2018] [Indexed: 11/22/2022] Open
Abstract
Background There is an urgent need for rapid, sensitive, and affordable diagnostics for microbial infections at the point-of-care. Although a number of innovative systems have been reported that transform mobile phones into potential diagnostic tools, the translational challenge to clinical diagnostics remains a significant hurdle to overcome. Methods A smartphone-based real-time loop-mediated isothermal amplification (smaRT-LAMP) system was developed for pathogen ID in urinary sepsis patients. The free, custom-built mobile phone app allows the phone to serve as a stand-alone device for quantitative diagnostics, allowing the determination of genome copy-number of bacterial pathogens in real time. Findings A head-to-head comparative bacterial analysis of urine from sepsis patients revealed that the performance of smaRT-LAMP matched that of clinical diagnostics at the admitting hospital in a fraction of the time (~1 h vs. 18–28 h). Among patients with bacteremic complications of their urinary sepsis, pathogen ID from the urine matched that from the blood – potentially allowing pathogen diagnosis shortly after hospital admission. Additionally, smaRT-LAMP did not exhibit false positives in sepsis patients with clinically negative urine cultures. Interpretation The smaRT-LAMP system is effective against diverse Gram-negative and -positive pathogens and biological specimens, costs less than $100 US to fabricate (in addition to the smartphone), and is configurable for the simultaneous detection of multiple pathogens. SmaRT-LAMP thus offers the potential to deliver rapid diagnosis and treatment of urinary tract infections and urinary sepsis with a simple test that can be performed at low cost at the point-of-care. Fund National Institutes of Health, Chan-Zuckerberg Biohub, Bill and Melinda Gates Foundation.
Collapse
|
15
|
Cytocoded passwords: BioMEMS based barcoding of biological samples for user authentication in microfluidic diagnostic devices. Biomed Microdevices 2018; 20:63. [PMID: 30066033 DOI: 10.1007/s10544-018-0306-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
Smart and connected point-of-care (POC) medical devices are becoming ever more ubiquitous and have the potential to radically improve disease diagnosis and health monitoring. This emerging connectivity can potentially create serious security issues where patient privacy can be easily compromised. Protection of patient data from malicious cyber-physical attackers requires radical solutions at the BioMEMS level. Ideally, the information exchange between the patient and practitioner is an automated and transparent process for the patient. In practice, this exchange requires both the patient and the test results to be authenticated and validated respectively on the storage service to ensure that the medical diagnostic results are properly stored and their access is protected. This secure authentication phase is particularly critical for medical diagnostics: patient data exposure could lead to negative social effects. This work focuses on providing a transparent authentication mechanism for patient blood tests performed using impedance flow cytometry. The goal is twofold: first, to alleviate the user from security procedures, precisely an authentication step, while using the medical device; second, to provide a unique identifier for the test results when stored in a remote server. This paper describes a domain specific authentication method for impedance flow cytometry devices. We spike into the blood samples synthetic micro-beads of different sizes, at determined concentrations, to generate a unique authentication string that uniquely identify a test result on the remote storage service. These authentication strings are embedded in the test devices and can be used as a convenient alternative to generic authentication methods, such as logins and passwords. This alternative method removes the authentication burden from the user and protects patient's privacy further by preventing them from linking their personal information to their test results.
Collapse
|
16
|
Chen LS, Singh RJ. Niche point-of-care endocrine testing - Reviews of intraoperative parathyroid hormone and cortisol monitoring. Crit Rev Clin Lab Sci 2018; 55:115-128. [PMID: 29357735 DOI: 10.1080/10408363.2018.1425975] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Point-of-care (POC) testing, which provides quick test results in near-patient settings with easy-to-use devices, has grown continually in recent decades. Among near-patient and on-site tests, rapid intraoperative and intra-procedural assays are used to quickly deliver critical information and thereby improve patient outcomes. Rapid intraoperative parathyroid hormone (ioPTH) monitoring measures postoperative reduction of parathyroid hormone (PTH) to predict surgical outcome in patients with primary hyperparathyroidism, and therefore contributes to the change of parathyroidectomy to a minimally invasive procedure. In this review, recent progress in applying ioPTH monitoring to patients with secondary and tertiary hyperparathyroidism and other testing areas is discussed. In-suite cortisol monitoring facilitates the use of adrenal vein sampling (AVS) for the differential diagnosis of primary aldosteronism and adrenocorticotropic hormone (ACTH)-independent Cushing syndrome. In clinical and psychological research settings, POC testing is also useful for rapidly assessing cortisol in plasma and saliva samples as a biomarker of stress. Careful resource utilization and coordination among stakeholders help to determine the best approach for implementing cost-effective POC testing. Technical advances in integrating appropriate biosensors with microfluidics-based devices hold promise for future real-time POC cortisol monitoring.
Collapse
Affiliation(s)
- Li-Sheng Chen
- a Bureau of Laboratories , Michigan Department of Health and Human Services , Lansing , MI , USA
| | - Ravinder J Singh
- b Laboratory Medicine and Pathology , Mayo Clinic , Rochester , MN , USA
| |
Collapse
|
17
|
Yang K, Wu J, Peretz-Soroka H, Zhu L, Li Z, Sang Y, Hipolito J, Zhang M, Santos S, Hillier C, de Faria RL, Liu Y, Lin F. M kit: A cell migration assay based on microfluidic device and smartphone. Biosens Bioelectron 2018; 99:259-267. [PMID: 28772229 PMCID: PMC5585005 DOI: 10.1016/j.bios.2017.07.064] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2017] [Revised: 07/15/2017] [Accepted: 07/21/2017] [Indexed: 11/23/2022]
Abstract
Mobile sensing based on the integration of microfluidic device and smartphone, so-called MS2 technology, has enabled many applications over recent years, and continues to stimulate growing interest in both research communities and industries. In particular, it has been envisioned that MS2 technology can be developed for various cell functional assays to enable basic research and clinical applications. Toward this direction, in this paper, we describe the development of a MS2-based cell functional assay for testing cell migration (the Mkit). The system is constructed as an integrated test kit, which includes microfluidic chips, a smartphone-based imaging platform, the phone apps for image capturing and data analysis, and a set of reagent and accessories for performing the cell migration assay. We demonstrated that the Mkit can effectively measure purified neutrophil and cancer cell chemotaxis. Furthermore, neutrophil chemotaxis can be tested from a drop of whole blood using the Mkit with red blood cell (RBC) lysis. The effects of chemoattractant dose and gradient profile on neutrophil chemotaxis were also tested using the Mkit. In addition to research applications, we demonstrated the effective use of the Mkit for on-site test at the hospital and for testing clinical samples from chronic obstructive pulmonary disease patient. Thus, this developed Mkit provides an easy and integrated experimental platform for cell migration related research and potential medical diagnostic applications.
Collapse
Affiliation(s)
- Ke Yang
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China; Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, Canada
| | - Jiandong Wu
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, Canada
| | - Hagit Peretz-Soroka
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, Canada
| | - Ling Zhu
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China
| | - Zhigang Li
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China
| | - Yaoshuo Sang
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China
| | - Jolly Hipolito
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, Canada
| | | | - Susy Santos
- Victoria General Hospital and River Heights/Fort Garry Community areas, Winnipeg, MB, Canada
| | | | | | - Yong Liu
- Institute of Applied Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, Anhui, PR China
| | - Francis Lin
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, Canada; Department of Biosystems Engineering, University of Manitoba, Winnipeg, MB, Canada; Department of Immunology, University of Manitoba, Winnipeg, MB, Canada; Department of Biological Sciences, University of Manitoba, Winnipeg, MB, Canada.
| |
Collapse
|
18
|
Improvement of a rapid diagnostic application of monoclonal antibodies against avian influenza H7 subtype virus using Europium nanoparticles. Sci Rep 2017; 7:7933. [PMID: 28801679 PMCID: PMC5554140 DOI: 10.1038/s41598-017-08328-9] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Accepted: 07/07/2017] [Indexed: 01/19/2023] Open
Abstract
The development of a sensitive and rapid diagnostic test is needed for early detection of avian influenza (AI) H7 subtype. In this study, novel monoclonal antibodies (mAbs) against influenza A H7N9 recombinant hemagglutinin (rHA)1 were developed and applied to a Europium nanoparticle–based rapid fluorescent immunochromatographic strip test (FICT) to improve the sensitivity of the rapid diagnostic system. Two antibodies (2F4 and 6D7) exhibited H7 subtype specificity in a dot-FICT assay by optimization of the conjugate and the pH of the lysis buffer. The subtype specificity was confirmed by an immunofluorescence assay and Western blot analysis. The limit of detection of the FICT employing novel mAbs 31 ng/mL for H7N9 rHA1 and 40 hemagglutination units/mL for H7 subtype virus. Sensitivity was improved 25-fold using Europium as confirmed by comparison of colloidal gold-based rapid diagnostic kit using the 2F4 and 6D7 mAbs.
Collapse
|
19
|
Neethirajan S, Ahmed SR, Chand R, Buozis J, Nagy É. Recent Advances in Biosensor Development for Foodborne Virus Detection. Nanotheranostics 2017; 1:272-295. [PMID: 29071193 PMCID: PMC5646734 DOI: 10.7150/ntno.20301] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2017] [Accepted: 05/07/2017] [Indexed: 11/05/2022] Open
Abstract
Outbreaks of foodborne diseases related to fresh produce have been increasing in North America and Europe. Viral foodborne pathogens are poorly understood, suffering from insufficient awareness and surveillance due to the limits on knowledge, availability, and costs of related technologies and devices. Current foodborne viruses are emphasized and newly emerging foodborne viruses are beginning to attract interest. To face current challenges regarding foodborne pathogens, a point-of-care (POC) concept has been introduced to food testing technology and device. POC device development involves technologies such as microfluidics, nanomaterials, biosensors and other advanced techniques. These advanced technologies, together with the challenges in developing foodborne virus detection assays and devices, are described and analysed in this critical review. Advanced technologies provide a path forward for foodborne virus detection, but more research and development will be needed to provide the level of manufacturing capacity required.
Collapse
Affiliation(s)
- Suresh Neethirajan
- BioNano Laboratory, School of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada
| | - Syed Rahin Ahmed
- BioNano Laboratory, School of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada
| | - Rohit Chand
- BioNano Laboratory, School of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada
| | - John Buozis
- BioNano Laboratory, School of Engineering, University of Guelph, Guelph, ON N1G 2W1, Canada
| | - Éva Nagy
- Department of Pathobiology, Ontario Veterinary College, University of Guelph, Guelph, ON N1G 2W1, Canada
| |
Collapse
|
20
|
Liu L, Zhang D, Zhang Q, Chen X, Xu G, Lu Y, Liu Q. Smartphone-based sensing system using ZnO and graphene modified electrodes for VOCs detection. Biosens Bioelectron 2017; 93:94-101. [DOI: 10.1016/j.bios.2016.09.084] [Citation(s) in RCA: 60] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2016] [Revised: 09/22/2016] [Accepted: 09/24/2016] [Indexed: 10/21/2022]
|
21
|
Abstract
A new generation of mobile sensing approaches offers significant advantages over traditional platforms in terms of test speed, control, low cost, ease-of-operation, and data management, and requires minimal equipment and user involvement. The marriage of novel sensing technologies with cellphones enables the development of powerful lab-on-smartphone platforms for many important applications including medical diagnosis, environmental monitoring, and food safety analysis. This paper reviews the recent advancements and developments in the field of smartphone-based food diagnostic technologies, with an emphasis on custom modules to enhance smartphone sensing capabilities. These devices typically comprise multiple components such as detectors, sample processors, disposable chips, batteries and software, which are integrated with a commercial smartphone. One of the most important aspects of developing these systems is the integration of these components onto a compact and lightweight platform that requires minimal power. To date, researchers have demonstrated several promising approaches employing various sensing techniques and device configurations. We aim to provide a systematic classification according to the detection strategy, providing a critical discussion of strengths and weaknesses. We have also extended the analysis to the food scanning devices that are increasingly populating the Internet of Things (IoT) market, demonstrating how this field is indeed promising, as the research outputs are quickly capitalized on new start-up companies.
Collapse
|
22
|
Bissonnette L, Bergeron MG. Portable devices and mobile instruments for infectious diseases point-of-care testing. Expert Rev Mol Diagn 2017; 17:471-494. [PMID: 28343420 DOI: 10.1080/14737159.2017.1310619] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
INTRODUCTION Rapidity, simplicity, and portability are highly desirable characteristics of tests and devices designed for performing diagnostics at the point of care (POC), either near patients managed in healthcare facilities or to offer bioanalytical alternatives in external settings. By reducing the turnaround time of the diagnostic cycle, POC diagnostics can reduce the dissemination, morbidity, and mortality of infectious diseases and provide tools to control the global threat of antimicrobial resistance. Areas covered: A literature search of PubMed and Google Scholar, and extensive mining of specialized publications, Internet resources, and manufacturers' websites have been used to organize and write this overview of the challenges and requirements associated with the development of portable sample-to-answer diagnostics, and showcase relevant examples of handheld devices, portable instruments, and less mobile systems which may or could be operated at POC. Expert commentary: Rapid (<1 h) diagnostics can contribute to control infectious diseases and antimicrobial resistant pathogens. Portable devices or instruments enabling sample-to-answer bioanalysis can provide rapid, robust, and reproducible testing at the POC or close from it. Beyond testing, to realize some promises of personalized/precision medicine, it will be critical to connect instruments to healthcare data management systems, to efficiently link decentralized testing results to the electronic medical record of patients.
Collapse
Affiliation(s)
- Luc Bissonnette
- a Centre de recherche en infectiologie de l'Université Laval, Axe maladies infectieuses et immunitaires, Centre de recherche du CHU de Québec-Université Laval , Québec City , Québec , Canada
| | - Michel G Bergeron
- a Centre de recherche en infectiologie de l'Université Laval, Axe maladies infectieuses et immunitaires, Centre de recherche du CHU de Québec-Université Laval , Québec City , Québec , Canada.,b Département de microbiologie-infectiologie et d'immunologie , Faculté de médecine, Université Laval , Québec City , Québec , Canada
| |
Collapse
|
23
|
Wu MYC, Hsu MY, Chen SJ, Hwang DK, Yen TH, Cheng CM. Point-of-Care Detection Devices for Food Safety Monitoring: Proactive Disease Prevention. Trends Biotechnol 2017; 35:288-300. [PMID: 28089198 DOI: 10.1016/j.tibtech.2016.12.005] [Citation(s) in RCA: 68] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2016] [Revised: 11/27/2016] [Accepted: 12/12/2016] [Indexed: 11/22/2022]
Abstract
Food safety has become an increasingly significant public concern in both developed and under-developed nations around the world; it increases morbidity, mortality, human suffering, and economic burden. This Opinion focuses on (i) examining the influence of pathogens and chemicals (e.g., food additives and pesticide residue) on food-borne illnesses, (ii) summarizing food hazards that are present in Asia, and (iii) summarizing the array of current point-of-care (POC) detection devices that have potential applications in food safety monitoring. In addition, we provide insight into global healthcare issues in both developing and under-developed nations with a focus on bridging the gap between food safety issues in the public sector (associated with relevant clinical cases) and the use of POC detection devices for food safety monitoring.
Collapse
Affiliation(s)
| | - Min-Yen Hsu
- Department of Ophthalmology, Taichung Veterans General Hospital, Taichung 407, Taiwan; School of Medicine, Chung Shan Medical University, Taichung 402, Taiwan
| | - Shih-Jen Chen
- Department of Ophthalmology, School of Medicine, National Yang-Ming University, Taipei 112, Taiwan
| | - De-Kuang Hwang
- Department of Ophthalmology, School of Medicine, National Yang-Ming University, Taipei 112, Taiwan
| | - Tzung-Hai Yen
- Poison Center, Department of Nephrology, Chang Gung Memorial Hospital and Chang Gung University, Linkou 333, Taiwan; Kidney Research Center, Chang Gung Memorial Hospital, Linkou 333, Taiwan; Center for Tissue Engineering, Chang Gung Memorial Hospital, Linkou 333, Taiwan.
| | - Chao-Min Cheng
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu 300, Taiwan.
| |
Collapse
|
24
|
Salles-Loustau G, Najafizadeh L, Javanmard M, Zonouz S. BioMEMS-based coding for secure medical diagnostic devices. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2017; 2016:4419-4422. [PMID: 28269258 DOI: 10.1109/embc.2016.7591707] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Trustworthy and usable point-of-care solutions require not only effective disease diagnostic procedures to ensure delivery of rapid and accurate outcomes, but also lightweight privacy-preserving capabilities. In this paper, we present a Biomedical Microelectromachanical System (BioMEMS)-based sensor for portable, inexpensive smartphone-based biomarker detection. The biosensor presented here provides the ability for signal encryption at the physical sensor level to ensure patient's diagnostic confidentiality. Our results show that this design allow us to protect the samples measurements while accurately distinguish different test samples.
Collapse
|
25
|
Li Z, Li Z, Zhao D, Wen F, Jiang J, Xu D. Smartphone-based visualized microarray detection for multiplexed harmful substances in milk. Biosens Bioelectron 2017; 87:874-880. [DOI: 10.1016/j.bios.2016.09.046] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 09/04/2016] [Accepted: 09/13/2016] [Indexed: 11/24/2022]
|
26
|
Exploiting NanoLuc luciferase for smartphone-based bioluminescence cell biosensor for (anti)-inflammatory activity and toxicity. Anal Bioanal Chem 2016; 408:8859-8868. [DOI: 10.1007/s00216-016-0062-3] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2016] [Accepted: 09/29/2016] [Indexed: 11/26/2022]
|
27
|
Yang Z, Zhan Q. Single-Shot Smartphone-Based Quantitative Phase Imaging Using a Distorted Grating. PLoS One 2016; 11:e0159596. [PMID: 27441837 PMCID: PMC4956142 DOI: 10.1371/journal.pone.0159596] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2016] [Accepted: 07/06/2016] [Indexed: 12/04/2022] Open
Abstract
Blood testing has been used as an essential tool to diagnose diseases for decades. Recently, there has been a rapid developing trend in using Quantitative Phase Imaging (QPI) methods for blood cell screening. Compared to traditional blood testing techniques, QPI has the advantage of avoiding dyeing or staining the specimen, which may cause damage to the cells. However, most existing systems are bulky and costly, requiring experienced personnel to operate. This work demonstrates the integration of one QPI method onto a smartphone platform and the application of imaging red blood cells. The adopted QPI method is based on solving the Intensity Transport Equation (ITE) from two de-focused pupil images taken in one shot by the smartphone camera. The device demonstrates a system resolution of about 1 μm, and is ready to be used for 3D morphological study of red blood cells.
Collapse
Affiliation(s)
- Zhenyu Yang
- Department of Electrical & Computer Engineering and Electro-Optics Program, University of Dayton, Dayton, Ohio, United States of America
- * E-mail:
| | - Qiwen Zhan
- Department of Electrical & Computer Engineering and Electro-Optics Program, University of Dayton, Dayton, Ohio, United States of America
| |
Collapse
|
28
|
Abstract
Sensitive detection of trimethylamine both in aqueous and gaseous phases has been accomplished using an inexpensive colorimetric sensor array. Distinctive color change patterns provide facile discrimination over a wide range of concentrations for trimethylamine with >99% accuracy of classification. Calculated limits of detection are well below the diagnostically significant concentration for trimethylaminuria (fish malodor syndrome). The sensor array shows good reversibility after multiple uses and is able to cleanly discriminate trimethylamine from similar amine odorants. Portable sensing of trimethylamine vapors at ppb concentrations is described using a cell phone camera or a hand-held optoelectronic nose. Application of the sensor array in detecting mouth and skin odor as a potential tool for portable diagnosis of trimethylaminuria is also illustrated.
Collapse
Affiliation(s)
- Zheng Li
- Department of Chemistry, University of Illinois at Urbana-Champaign , 600 S. Mathews Avenue, Urbana, Illinois 61801, United States
| | - Hao Li
- Department of Chemistry, University of Illinois at Urbana-Champaign , 600 S. Mathews Avenue, Urbana, Illinois 61801, United States
| | - Maria K LaGasse
- Department of Chemistry, University of Illinois at Urbana-Champaign , 600 S. Mathews Avenue, Urbana, Illinois 61801, United States
| | - Kenneth S Suslick
- Department of Chemistry, University of Illinois at Urbana-Champaign , 600 S. Mathews Avenue, Urbana, Illinois 61801, United States
| |
Collapse
|
29
|
Trzcinski P, Weagant S, Karanassios V. Wireless Data Acquisition of Transient Signals for Mobile Spectrometry Applications. APPLIED SPECTROSCOPY 2016; 70:905-915. [PMID: 27006023 DOI: 10.1177/0003702816638304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2015] [Accepted: 01/22/2016] [Indexed: 06/05/2023]
Abstract
Wireless data acquisition using smartphones or handhelds offers increased mobility, it provides reduced size and weight, it has low electrical power requirements, and (in some cases) it has an ability to access the internet. Thus, it is well suited for mobile spectrometry applications using miniaturized, field-portable spectrometers, or detectors for chemical analysis in the field (i.e., on-site). There are four main wireless communications standards that can be used for wireless data acquisition, namely ZigBee, Bluetooth, Wi-Fi, and UWB (ultra-wide band). These are briefly reviewed and are evaluated for applicability to data acquisition of transient signals (i.e., time-domain) in the field (i.e., on-site) from a miniaturized, field-portable photomultiplier tube detector and from a photodiode array detector installed in a miniaturized, field-portable fiber optic spectrometer. These are two of the most widely used detectors for optical measurements in the ultraviolet-visible range of the spectrum. A miniaturized, 3D-printed, battery-operated microplasma-on-a-chip was used for generation of transient optical emission signals. Elemental analysis from liquid microsamples, a microplasma, and a handheld or a smartphone will be used as examples. Development and potential applicability of wireless data acquisition of transient optical emission signals for taking part of the lab to the sample types of mobile, field-portable spectrometry applications will be discussed. The examples presented are drawn from past and ongoing work in the authors' laboratory. A handheld or a smartphone were used as the mobile computing devices of choice.
Collapse
Affiliation(s)
- Peter Trzcinski
- Department of Chemistry and Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, Canada
| | - Scott Weagant
- Department of Chemistry and Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, Canada
| | - Vassili Karanassios
- Department of Chemistry and Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, Canada
| |
Collapse
|
30
|
Yang K, Peretz-Soroka H, Liu Y, Lin F. Novel developments in mobile sensing based on the integration of microfluidic devices and smartphones. LAB ON A CHIP 2016; 16:943-58. [PMID: 26899264 PMCID: PMC5142836 DOI: 10.1039/c5lc01524c] [Citation(s) in RCA: 111] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Portable electronic devices and wireless communication systems enable a broad range of applications such as environmental and food safety monitoring, personalized medicine and healthcare management. Particularly, hybrid smartphone and microfluidic devices provide an integrated solution for the new generation of mobile sensing applications. Such mobile sensing based on microfluidic devices (broadly defined) and smartphones (MS(2)) offers a mobile laboratory for performing a wide range of bio-chemical detection and analysis functions such as water and food quality analysis, routine health tests and disease diagnosis. MS(2) offers significant advantages over traditional platforms in terms of test speed and control, low cost, mobility, ease-of-operation and data management. These improvements put MS(2) in a promising position in the fields of interdisciplinary basic and applied research. In particular, MS(2) enables applications to remote in-field testing, homecare, and healthcare in low-resource areas. The marriage of smartphones and microfluidic devices offers a powerful on-chip operating platform to enable various bio-chemical tests, remote sensing, data analysis and management in a mobile fashion. The implications of such integration are beyond telecommunication and microfluidic-related research and technology development. In this review, we will first provide the general background of microfluidic-based sensing, smartphone-based sensing, and their integration. Then, we will focus on several key application areas of MS(2) by systematically reviewing the important literature in each area. We will conclude by discussing our perspectives on the opportunities, issues and future directions of this emerging novel field.
Collapse
Affiliation(s)
- Ke Yang
- Institute of Applied Technology, Hefei Institute of Physical Science, Chinese Academy of Sciences, P. O. Box 1126, Hefei, 230031, P.R. China
- University of Science and Technology of China, Hefei, 230026, P.R. China
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada
| | - Hagit Peretz-Soroka
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada
| | - Yong Liu
- Institute of Applied Technology, Hefei Institute of Physical Science, Chinese Academy of Sciences, P. O. Box 1126, Hefei, 230031, P.R. China
| | - Francis Lin
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada
- Department of Biosystems Engineering, University of Manitoba, Winnipeg, MB, R3T 5V6, Canada
- Department of Immunology, University of Manitoba, Winnipeg, MB, R3E 0T5, Canada
- Department of Biological Sciences, University of Manitoba, Winnipeg, MB, R3T 2N2, Canada
| |
Collapse
|
31
|
Yeo SJ, Choi K, Cuc BT, Hong NN, Bao DT, Ngoc NM, Le MQ, Hang NLK, Thach NC, Mallik SK, Kim HS, Chong CK, Choi HS, Sung HW, Yu K, Park H. Smartphone-Based Fluorescent Diagnostic System for Highly Pathogenic H5N1 Viruses. Am J Cancer Res 2016; 6:231-42. [PMID: 26877781 PMCID: PMC4729771 DOI: 10.7150/thno.14023] [Citation(s) in RCA: 74] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Accepted: 11/19/2015] [Indexed: 12/22/2022] Open
Abstract
Field diagnostic tools for avian influenza (AI) are indispensable for the prevention and controlled management of highly pathogenic AI-related diseases. More accurate, faster and networked on-site monitoring is demanded to detect such AI viruses with high sensitivity as well as to maintain up-to-date information about their geographical transmission. In this work, we assessed the clinical and field-level performance of a smartphone-based fluorescent diagnostic device with an efficient reflective light collection module using a coumarin-derived dendrimer-based fluorescent lateral flow immunoassay. By application of an optimized bioconjugate, a smartphone-based diagnostic device had a two-fold higher detectability as compared to that of the table-top fluorescence strip reader for three different AI subtypes (H5N3, H7N1, and H9N2). Additionally, in a clinical study of H5N1-confirmed patients, the smartphone-based diagnostic device showed a sensitivity of 96.55% (28/29) [95% confidence interval (CI): 82.24 to 99.91] and a specificity of 98.55% (68/69) (95% CI: 92.19 to 99.96). The measurement results from the distributed individual smartphones were wirelessly transmitted via short messaging service and collected by a centralized database system for further information processing and data mining. Smartphone-based diagnosis provided highly sensitive measurement results for H5N1 detection within 15 minutes. Because of its high sensitivity, portability and automatic reporting feature, the proposed device will enable agile identification of patients and efficient control of AI dissemination.
Collapse
|
32
|
Integrated Microfluidic Nucleic Acid Isolation, Isothermal Amplification, and Amplicon Quantification. MICROARRAYS 2015; 4:474-89. [PMID: 27600235 PMCID: PMC4996405 DOI: 10.3390/microarrays4040474] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2015] [Revised: 10/02/2015] [Accepted: 10/10/2015] [Indexed: 02/06/2023]
Abstract
Microfluidic components and systems for rapid (<60 min), low-cost, convenient, field-deployable sequence-specific nucleic acid-based amplification tests (NAATs) are described. A microfluidic point-of-care (POC) diagnostics test to quantify HIV viral load from blood samples serves as a representative and instructive example to discuss the technical issues and capabilities of “lab on a chip” NAAT devices. A portable, miniaturized POC NAAT with performance comparable to conventional PCR (polymerase-chain reaction)-based tests in clinical laboratories can be realized with a disposable, palm-sized, plastic microfluidic chip in which: (1) nucleic acids (NAs) are extracted from relatively large (~mL) volume sample lysates using an embedded porous silica glass fiber or cellulose binding phase (“membrane”) to capture sample NAs in a flow-through, filtration mode; (2) NAs captured on the membrane are isothermally (~65 °C) amplified; (3) amplicon production is monitored by real-time fluorescence detection, such as with a smartphone CCD camera serving as a low-cost detector; and (4) paraffin-encapsulated, lyophilized reagents for temperature-activated release are pre-stored in the chip. Limits of Detection (LOD) better than 103 virons/sample can be achieved. A modified chip with conduits hosting a diffusion-mode amplification process provides a simple visual indicator to readily quantify sample NA template. In addition, a companion microfluidic device for extracting plasma from whole blood without a centrifuge, generating cell-free plasma for chip-based molecular diagnostics, is described. Extensions to a myriad of related applications including, for example, food testing, cancer screening, and insect genotyping are briefly surveyed.
Collapse
|
33
|
Medically relevant assays with a simple smartphone and tablet based fluorescence detection system. SENSORS 2015; 15:11653-64. [PMID: 26007723 PMCID: PMC4481933 DOI: 10.3390/s150511653] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2015] [Accepted: 05/17/2015] [Indexed: 12/12/2022]
Abstract
Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera) and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate separates excitation light from assay fluorescence emission enabling assay readout with a smartphone camera. The assay result is obtained by analysing the intensity of image pixels in an appropriate colour channel. With this device we carried out two assays, for collagenase and trypsin using fluorescein as the detected fluorophore. The results of collagenase assay with the lowest measured concentration of 3.75 µg/mL and 0.938 µg in total in the sample were comparable to those obtained by a microplate reader. The lowest measured amount of trypsin was 930 pg, which is comparable to the low detection limit of 400 pg for this assay obtained in a microplate reader. The device is sensitive enough to be used in point-of-care medical diagnostics of clinically relevant conditions, including arthritis, cystic fibrosis and acute pancreatitis.
Collapse
|
34
|
|
35
|
Gulley ML, Morgan DR. Molecular oncology testing in resource-limited settings. J Mol Diagn 2014; 16:601-11. [PMID: 25242061 PMCID: PMC4210462 DOI: 10.1016/j.jmoldx.2014.07.002] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2014] [Revised: 07/15/2014] [Accepted: 07/22/2014] [Indexed: 12/14/2022] Open
Abstract
Cancer prevalence and mortality are high in developing nations, where resources for cancer control are inadequate. Nearly one-quarter of cancers in resource-limited nations are infection related, and molecular assays can capitalize on this relationship by detecting pertinent pathogen genomes and human gene variants to identify those at highest risk for progression to cancer, to classify lesions, to predict effective therapy, and to monitor tumor burden over time. Prime examples are human papillomavirus in cervical neoplasia, Helicobacter pylori and Epstein-Barr virus in gastric adenocarcinoma and lymphoma, and hepatitis B or C virus in hepatocellular cancer. Research is underway to engineer devices that overcome social, economic, and technical barriers limiting effective laboratory support. Additional challenges include an educated workforce, infrastructure for quality metrics and record keeping, and funds to sustain molecular test services. The combination of well-designed interfaces, novel and robust electrochemical technology, and telemedicine tools will promote adoption by frontline providers. Fast turnaround is crucial for surmounting loss to follow-up, although increased use of cell phones, even in rural areas, enhances options for patient education and engagement. Links to a broadband network facilitate consultation and centralized storage of medical data. Molecular technology shows promise to address gaps in health care through rapid, user-friendly, and cost-effective devices reflecting clinical priorities in resource-poor areas.
Collapse
Affiliation(s)
- Margaret L Gulley
- Department of Pathology and Laboratory Medicine, Lineberger Comprehensive Cancer Center, University of North Carolina, Chapel Hill, North Carolina.
| | - Douglas R Morgan
- Division of Gastroenterology, Hepatology, and Nutrition, Vanderbilt University, Nashville, Tennessee
| |
Collapse
|