1
|
Le LV, Mkrtschjan MA, Russell B, Desai TA. Hang on tight: reprogramming the cell with microstructural cues. Biomed Microdevices 2019; 21:43. [PMID: 30955102 PMCID: PMC6791714 DOI: 10.1007/s10544-019-0394-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Cells interact intimately with complex microdomains in their extracellular matrix (ECM) and maintain a delicate balance of mechanical forces through mechanosensitive cellular components. Tissue injury results in acute degradation of the ECM and disruption of cell-ECM contacts, manifesting in loss of cytoskeletal tension, leading to pathological cell transformation and the onset of disease. Recently, microscale hydrogel constructs have been developed to provide cells with microdomains to form focal adhesion binding sites, which enable restoration of cytoskeletal tension. These synthetic anchors can recapitulate the complex 3D architecture of the native ECM to provide microtopographical cues. The mechanical deformation of proteins at the cell surface can activate signaling cascades to modulate downstream gene-level transcription, making this a unique materials-based approach for reprogramming cell behavior. An overview of the mechanisms underlying these mechanosensitive interactions in fibroblasts, stem and other cell types is provided to review their effects on cellular reprogramming. Recent investigations on the fabrication, functionalization and implementation of these materials and microtopographical features for drug testing and therapeutic applications are discussed.
Collapse
Affiliation(s)
- Long V Le
- Department of Bioengineering and Therapeutic Sciences, University of California, 1700 4th St Rm 204, San Francisco, CA, 94158, USA
| | - Michael A Mkrtschjan
- Department of Bioengineering, University of Illinois, Chicago, 835 S. Wolcott, Chicago, IL, 60612, USA
| | - Brenda Russell
- Department of Physiology and Biophysics, University of Illinois, Chicago, 835 S. Wolcott, Chicago, IL, 60612, USA
| | - Tejal A Desai
- Department of Bioengineering and Therapeutic Sciences, University of California, 1700 4th St Rm 204, San Francisco, CA, 94158, USA.
| |
Collapse
|
2
|
Ajami S, Coathup MJ, Khoury J, Blunn GW. Augmenting the bioactivity of polyetheretherketone using a novel accelerated neutral atom beam technique. J Biomed Mater Res B Appl Biomater 2016; 105:1438-1446. [PMID: 27086858 DOI: 10.1002/jbm.b.33681] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2015] [Revised: 03/22/2016] [Accepted: 03/29/2016] [Indexed: 01/27/2023]
Abstract
Polyetheretherketone (PEEK) is an alternative to metallic implants in orthopedic applications; however, PEEK is bioinert and does not osteointegrate. In this study, an accelerated neutral atom beam technique (ANAB) was employed to improve the bioactivity of PEEK. The aim was to investigate the growth of human mesenchymal stem cells (hMSCs), human osteoblasts (hOB), and skin fibroblasts (BR3G) on PEEK and ANAB PEEK. METHODS The surface roughness and contact angle of PEEK and ANAB PEEK was measured. Cell metabolic activity, proliferation and alkaline phosphatase (ALP) was measured and cell attachment was determined by quantifying adhesion plaques with cells. RESULTS ANAB treatment increased the surface hydrophilicity [91.74 ± 4.80° (PEEK) vs. 74.82 ± 2.70° (ANAB PEEK), p < 0.001] but did not alter the surface roughness. Metabolic activity and proliferation for all cell types significantly increased on ANAB PEEK compared to PEEK (p < 0.05). Significantly increased cell attachment was measured on ANAB PEEK surfaces. MSCs seeded on ANAB PEEK in the presence of osteogenic media, expressed increased levels of ALP compared to untreated PEEK (p < 0.05) CONCLUSION: Our results demonstrated that ANAB treatment increased the cell attachment, metabolic activity, and proliferation on PEEK. ANAB treatment may improve the osteointegration of PEEK implants. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1438-1446, 2017.
Collapse
Affiliation(s)
- S Ajami
- John Scales Centre for Biomedical Engineering, Institute of Orthopaedics, Division of Surgery, University College London, London, UK
| | - M J Coathup
- John Scales Centre for Biomedical Engineering, Institute of Orthopaedics, Division of Surgery, University College London, London, UK
| | - J Khoury
- Exogenesis Corp., Billerica, Massachusetts, 01821
| | - G W Blunn
- John Scales Centre for Biomedical Engineering, Institute of Orthopaedics, Division of Surgery, University College London, London, UK
| |
Collapse
|
3
|
Tallawi M, Rai R, Boccaccini AR, Aifantis KE. Effect of substrate mechanics on cardiomyocyte maturation and growth. TISSUE ENGINEERING PART B-REVIEWS 2014; 21:157-65. [PMID: 25148904 DOI: 10.1089/ten.teb.2014.0383] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Cardiac tissue engineering constructs are a promising therapeutic treatment for myocardial infarction, which is one of the leading causes of death. In order to further advance the development and regeneration of engineered cardiac tissues using biomaterial platforms, it is important to have a complete overview of the effects that substrates have on cardiomyocyte (CM) morphology and function. This article summarizes recent studies that investigate the effect of mechanical cues on the CM differentiation, maturation, and growth. In these studies, CMs derived from embryos, neonates, and mesenchymal stem cells were seeded on different substrates of various elastic modulus. Measuring the contractile function by force production, work output, and calcium handling, it was seen that cell behavior on substrates was optimized when the substrate stiffness mimicked that of the native tissue. The contractile function reflected changes in the sarcomeric protein confirmation and organization that promoted the contractile ability. The analysis of the literature also revealed that, in addition to matrix stiffness, mechanical stimulation, such as stretching the substrate during cell seeding, also played an important role during cell maturation and tissue development.
Collapse
Affiliation(s)
- Marwa Tallawi
- 1 Department of Materials Science and Engineering, Institute of Biomaterials, University of Erlangen-Nuremberg , Erlangen, Germany
| | | | | | | |
Collapse
|
4
|
Pinney JR, Du KT, Ayala P, Fang Q, Sievers RE, Chew P, Delrosario L, Lee RJ, Desai TA. Discrete microstructural cues for the attenuation of fibrosis following myocardial infarction. Biomaterials 2014; 35:8820-8828. [PMID: 25047625 DOI: 10.1016/j.biomaterials.2014.07.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2014] [Accepted: 07/02/2014] [Indexed: 01/14/2023]
Abstract
Chronic fibrosis caused by acute myocardial infarction (MI) leads to increased morbidity and mortality due to cardiac dysfunction. We have developed a therapeutic materials strategy that aims to mitigate myocardial fibrosis by utilizing injectable polymeric microstructures to mechanically alter the microenvironment. Polymeric microstructures were fabricated using photolithographic techniques and studied in a three-dimensional culture model of the fibrotic environment and by direct injection into the infarct zone of adult rats. Here, we show dose-dependent down-regulation of expression of genes associated with the mechanical fibrotic response in the presence of microstructures. Injection of this microstructured material into the infarct zone decreased levels of collagen and TGF-β, increased elastin deposition and vascularization in the infarcted region, and improved functional outcomes after six weeks. Our results demonstrate the efficacy of these discrete anti-fibrotic microstructures and suggest a potential therapeutic materials approach for combatting pathologic fibrosis.
Collapse
Affiliation(s)
- James R Pinney
- UC Berkeley - UCSF Graduate Group in Bioengineering, 1700 4th Street, QB3 Byers Hall, Room 203, San Francisco, CA 94158, USA; UCSF Medical Scientist Training Program, 1700 4th Street, QB3 Byers Hall, Room 203, San Francisco, CA 94158, USA
| | - Kim T Du
- UCSF Department of Medicine, Cardiovascular Research Institute and Eli and Edythe Broad Center of Regeneration Medicine and Stem Cell Research, Box 1354, 513 Parnassus Ave, MS Room 1136, San Francisco, CA 94143, USA
| | - Perla Ayala
- UC Berkeley - UCSF Graduate Group in Bioengineering, 1700 4th Street, QB3 Byers Hall, Room 203, San Francisco, CA 94158, USA; Beth Israel Deaconess Medical Center, Department of Surgery, Center for Life Science Surgery/BIDMC, 11th Floor, 3 Blackfan Circle, Boston, MA 02115, USA
| | - Qizhi Fang
- UCSF Department of Medicine, Cardiovascular Research Institute and Eli and Edythe Broad Center of Regeneration Medicine and Stem Cell Research, Box 1354, 513 Parnassus Ave, MS Room 1136, San Francisco, CA 94143, USA
| | - Richard E Sievers
- UCSF Department of Medicine, Cardiovascular Research Institute and Eli and Edythe Broad Center of Regeneration Medicine and Stem Cell Research, Box 1354, 513 Parnassus Ave, MS Room 1136, San Francisco, CA 94143, USA
| | - Patrick Chew
- UCSF Bioengineering and Therapeutic Sciences, 1700 4th Street, Byers Hall Room 203, San Francisco, CA 94158, USA
| | - Lawrence Delrosario
- UCSF School of Medicine, 513 Parnassus Ave, MS Room 1136, San Francisco, CA 94143, USA
| | - Randall J Lee
- UC Berkeley - UCSF Graduate Group in Bioengineering, 1700 4th Street, QB3 Byers Hall, Room 203, San Francisco, CA 94158, USA; UCSF Department of Medicine, Cardiovascular Research Institute and Eli and Edythe Broad Center of Regeneration Medicine and Stem Cell Research, Box 1354, 513 Parnassus Ave, MS Room 1136, San Francisco, CA 94143, USA
| | - Tejal A Desai
- UC Berkeley - UCSF Graduate Group in Bioengineering, 1700 4th Street, QB3 Byers Hall, Room 203, San Francisco, CA 94158, USA; UCSF Bioengineering and Therapeutic Sciences, 1700 4th Street, Byers Hall Room 203, San Francisco, CA 94158, USA.
| |
Collapse
|
5
|
Oakes PW, Gardel ML. Stressing the limits of focal adhesion mechanosensitivity. Curr Opin Cell Biol 2014; 30:68-73. [PMID: 24998185 DOI: 10.1016/j.ceb.2014.06.003] [Citation(s) in RCA: 102] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2014] [Revised: 06/10/2014] [Accepted: 06/11/2014] [Indexed: 01/09/2023]
Abstract
Focal adhesion assembly and maturation often occurs concomitantly with changes in force generated within the cytoskeleton or extracellular matrix. To coordinate focal adhesion dynamics with force, it has been suggested that focal adhesion dynamics are mechanosensitive. This review discusses current understanding of the regulation of focal adhesion assembly and force transmission, and the limits to which we can consider focal adhesion plaques as mechanosensitive entities.
Collapse
Affiliation(s)
- Patrick W Oakes
- James Franck Institute, Institute for Biophysical Dynamics and Physics Department, University of Chicago, Chicago, IL, United States
| | - Margaret L Gardel
- James Franck Institute, Institute for Biophysical Dynamics and Physics Department, University of Chicago, Chicago, IL, United States.
| |
Collapse
|
6
|
de Peppo GM, Agheli H, Karlsson C, Ekström K, Brisby H, Lennerås M, Gustafsson S, Sjövall P, Johansson A, Olsson E, Lausmaa J, Thomsen P, Petronis S. Osteogenic response of human mesenchymal stem cells to well-defined nanoscale topography in vitro. Int J Nanomedicine 2014; 9:2499-515. [PMID: 24904210 PMCID: PMC4039423 DOI: 10.2147/ijn.s58805] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
BACKGROUND Patterning medical devices at the nanoscale level enables the manipulation of cell behavior and tissue regeneration, with topographic features recognized as playing a significant role in the osseointegration of implantable devices. METHODS In this study, we assessed the ability of titanium-coated hemisphere-like topographic nanostructures of different sizes (approximately 50, 100, and 200 nm) to influence the morphology, proliferation, and osteogenic differentiation of human mesenchymal stem cells (hMSCs). RESULTS We found that the proliferation and osteogenic differentiation of hMSCs was influenced by the size of the underlying structures, suggesting that size variations in topographic features at the nanoscale level, independently of chemistry, can be exploited to control hMSC behavior in a size-dependent fashion. CONCLUSION Our studies demonstrate that colloidal lithography, in combination with coating technologies, can be exploited to investigate the cell response to well defined nanoscale topography and to develop next-generation surfaces that guide tissue regeneration and promote implant integration.
Collapse
Affiliation(s)
- Giuseppe Maria de Peppo
- The New York Stem Cell Foundation Research Institute, New York, NY, USA
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, University of Gothenburg, Göteborg, Sweden
| | - Hossein Agheli
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, University of Gothenburg, Göteborg, Sweden
| | - Camilla Karlsson
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, University of Gothenburg, Göteborg, Sweden
| | - Karin Ekström
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, University of Gothenburg, Göteborg, Sweden
| | - Helena Brisby
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, University of Gothenburg, Göteborg, Sweden
- Department of Orthopaedics, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
| | - Maria Lennerås
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, University of Gothenburg, Göteborg, Sweden
| | - Stefan Gustafsson
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, University of Gothenburg, Göteborg, Sweden
- Applied Physics, Chalmers University of Technology, Göteborg, Sweden
| | - Peter Sjövall
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, University of Gothenburg, Göteborg, Sweden
- Applied Physics, Chalmers University of Technology, Göteborg, Sweden
- Chemistry, Materials and Surfaces, SP Technical Research Institute of Sweden, Borås, Sweden
| | - Anna Johansson
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, University of Gothenburg, Göteborg, Sweden
| | - Eva Olsson
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, University of Gothenburg, Göteborg, Sweden
- Applied Physics, Chalmers University of Technology, Göteborg, Sweden
| | - Jukka Lausmaa
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, University of Gothenburg, Göteborg, Sweden
- Chemistry, Materials and Surfaces, SP Technical Research Institute of Sweden, Borås, Sweden
| | - Peter Thomsen
- Department of Biomaterials, Sahlgrenska Academy, University of Gothenburg, Göteborg, Sweden
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, University of Gothenburg, Göteborg, Sweden
| | - Sarunas Petronis
- BIOMATCELL VINN Excellence Center of Biomaterials and Cell Therapy, University of Gothenburg, Göteborg, Sweden
- Chemistry, Materials and Surfaces, SP Technical Research Institute of Sweden, Borås, Sweden
| |
Collapse
|
7
|
Zellander A, Zhao C, Kotecha M, Gemeinhart R, Wardlow M, Abiade J, Cho M. Characterization of pore structure in biologically functional poly(2-hydroxyethyl methacrylate)-poly(ethylene glycol) diacrylate (PHEMA-PEGDA). PLoS One 2014; 9:e96709. [PMID: 24816589 PMCID: PMC4016039 DOI: 10.1371/journal.pone.0096709] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2013] [Accepted: 04/11/2014] [Indexed: 11/19/2022] Open
Abstract
A copolymer composed of poly(2-hydroxyethyl methacrylate) (PHEMA) and poly(ethylene glycol) diacrylate (PEGDA) (PHEMA-PEGDA) is structurally versatile. Its structure can be adjusted using the following porogens: water, sucrose, and benzyl alcohol. Using phase separation technique, a variety of surface architectures and pore morphologies were developed by adjusting porogen volume and type. The water and sucrose porogens were effective in creating porous and cytocompatible PHEMA-PEGDA scaffolds. When coated with collagen, the PHEMA-PEGDA scaffolds accommodated cell migration. The PHEMA-PEGDA scaffolds are easy to produce, non-toxic, and mechanically stable enough to resist fracture during routine handling. The PHEMA-PEGDA structures presented in this study may expedite the current research effort to engineer tissue scaffolds that provide both structural stability and biological activity.
Collapse
Affiliation(s)
- Amelia Zellander
- Department of Bioengineering, University of Illinois, Chicago, Illinois, United States of America
| | - Chenlin Zhao
- Department of Mechanical and Industrial Engineering, University of Illinois, Chicago, Illinois, United States of America
| | - Mrignayani Kotecha
- Department of Bioengineering, University of Illinois, Chicago, Illinois, United States of America
| | - Richard Gemeinhart
- Department of Biopharmaceutical Sciences, University of Illinois, Chicago, Illinois, United States of America
| | - Melissa Wardlow
- Department of Bioengineering, University of Illinois, Chicago, Illinois, United States of America
| | - Jeremiah Abiade
- Department of Mechanical and Industrial Engineering, University of Illinois, Chicago, Illinois, United States of America
| | - Michael Cho
- Department of Bioengineering, University of Illinois, Chicago, Illinois, United States of America
- * E-mail:
| |
Collapse
|
8
|
Gupta SK, Dinda AK, Potdar PD, Mishra NC. Fabrication and characterization of scaffold from cadaver goat-lung tissue for skin tissue engineering applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2013; 33:4032-8. [PMID: 23910311 DOI: 10.1016/j.msec.2013.05.045] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2013] [Revised: 05/06/2013] [Accepted: 05/21/2013] [Indexed: 12/11/2022]
Abstract
The present study aims to fabricate scaffold from cadaver goat-lung tissue and evaluate it for skin tissue engineering applications. Decellularized goat-lung scaffold was fabricated by removing cells from cadaver goat-lung tissue enzymatically, to have cell-free 3D-architecture of natural extracellular matrix. DNA quantification assay and Hematoxylin and eosin staining confirmed the absence of cellular material in the decellularized lung-tissue. SEM analysis of decellularized scaffold shows the intrinsic porous structure of lung tissue with well-preserved pore-to-pore interconnectivity. FTIR analysis confirmed non-denaturation and well maintainance of collagenous protein structure of decellularized scaffold. MTT assay, SEM analysis and H&E staining of human skin-derived Mesenchymal Stem cell, seeded over the decellularized scaffold, confirms stem cell attachment, viability, biocompatibility and proliferation over the decellularized scaffold. Expression of Keratin18 gene, along with CD105, CD73 and CD44, by human skin-derived Mesenchymal Stem cells over decellularized scaffold signifies that the cells are viable, proliferating and migrating, and have maintained their critical cellular functions in the presence of scaffold. Thus, overall study proves the applicability of the goat-lung tissue derived decellularized scaffold for skin tissue engineering applications.
Collapse
Affiliation(s)
- Sweta K Gupta
- Department of Polymer and Process Engineering, Indian Institute of Technology, Roorkee, India
| | | | | | | |
Collapse
|
9
|
Curtis MW, Budyn E, Desai TA, Samarel AM, Russell B. Microdomain heterogeneity in 3D affects the mechanics of neonatal cardiac myocyte contraction. Biomech Model Mechanobiol 2013; 12:95-109. [PMID: 22407215 PMCID: PMC3407350 DOI: 10.1007/s10237-012-0384-9] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2011] [Accepted: 02/23/2012] [Indexed: 01/26/2023]
Abstract
Cardiac muscle cells are known to adapt to their physical surroundings, optimizing intracellular organization and contractile function for a given culture environment. A previously developed in vitro model system has shown that the inclusion of discrete microscale domains (or microrods) in three dimensions (3D) can alter long-term growth responses of neonatal ventricular myocytes. The aim of this work was to understand how cellular contact with such a domain affects various mechanical changes involved in cardiac muscle cell remodeling. Myocytes were maintained in 3D gels over 5 days in the presence or absence of 100-μm-long microrods, and the effect of this local heterogeneity on cell behavior was analyzed via several imaging techniques. Microrod abutment resulted in approximately twofold increases in the maximum displacement of spontaneously beating myocytes, as based on confocal microscopy scans of the gel xy-plane or the myocyte long axis. In addition, microrods caused significant increases in the proportion of aligned myofibrils (≤20° deviation from long axis) in fixed myocytes. Microrod-related differences in axial contraction could be abrogated by long-term interruption of certain signals of the RhoA-/Rho-associated kinase (ROCK) or protein kinase C (PKC) pathway. Furthermore, microrod-induced increases in myocyte size and protein content were prevented by ROCK inhibition. In all, the data suggest that microdomain heterogeneity in 3D appears to promote the development of axially aligned contractile machinery in muscle cells, an observation that may have relevance to a number of cardiac tissue engineering interventions.
Collapse
Affiliation(s)
- Matthew W. Curtis
- Department of Physiology and Biophysics, University of Illinois at Chicago, 835 South Wolcott Avenue, Chicago, IL 60612, USA
| | - Elisa Budyn
- Department of Mechanical and Industrial Engineering, University of Illinois at Chicago, Chicago, IL, USA
| | - Tejal A. Desai
- Department of Physiology and Division of Bioengineering, University of California at San Francisco, San Francisco, CA, USA
| | - Allen M. Samarel
- The Cardiovascular Institute, Loyola University Medical Center, Maywood, IL, USA
| | - Brenda Russell
- Department of Physiology and Biophysics, University of Illinois at Chicago, 835 South Wolcott Avenue, Chicago, IL 60612, USA,
| |
Collapse
|
10
|
Lawrence BD, Pan Z, Weber MD, Kaplan DL, Rosenblatt MI. Silk film culture system for in vitro analysis and biomaterial design. J Vis Exp 2012:3646. [PMID: 22565786 PMCID: PMC3466641 DOI: 10.3791/3646] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Silk films are promising protein-based biomaterials that can be fabricated with high fidelity and economically within a research laboratory environment 1,2 . These materials are desirable because they possess highly controllable dimensional and material characteristics, are biocompatible and promote cell adhesion, can be modified through topographic patterning or by chemically altering the surface, and can be used as a depot for biologically active molecules for drug delivery related applications 3-8 . In addition, silk films are relatively straightforward to custom design, can be designed to dissolve within minutes or degrade over years in vitro or in vivo, and are produce with the added benefit of being transparent in nature and therefore highly suitable for imaging applications 9-13. The culture system methodology presented here represents a scalable approach for rapid assessments of cell-silk film surface interactions. Of particular interest is the use of surface patterned silk films to study differences in cell proliferation and responses of cells for alignment 12,14 . The seeded cultures were cultured on both micro-patterned and flat silk film substrates, and then assessed through time-lapse phase-contrast imaging, scanning electron microscopy, and biochemical assessment of metabolic activity and nucleic acid content. In summary, the silk film in vitro culture system offers a customizable experimental setup suitable to the study of cell-surface interactions on a biomaterial substrate, which can then be optimized and then translated to in vivo models. Observations using the culture system presented here are currently being used to aid in applications ranging from basic cell interactions to medical device design, and thus are relevant to a broad range of biomedical fields.
Collapse
Affiliation(s)
- Brian D Lawrence
- Margaret M. Dyson Vision Research Institute, Weill Cornell Medical College, USA
| | | | | | | | | |
Collapse
|
11
|
Srinivasan N, Kumar S. Ordered and disordered proteins as nanomaterial building blocks. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2012; 4:204-18. [PMID: 22231983 DOI: 10.1002/wnan.1160] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
Abstract
Proteins possess a number of attractive properties that have contributed to their recent emergence as nanoscale building blocks for biomaterials and bioinspired materials. For instance, the amino acid sequence of a protein can be precisely controlled and manipulated via recombinant DNA technology, and proteins can be biosynthesized with very high purity and virtually perfect monodispersity. Most importantly, protein-based biomaterials offer the possibility of technologically harnessing the vast array of functions that these biopolymers serve in nature. In this review, we discuss recent progress in the field of protein-based biomaterials, with an overall theme of relating protein structure to material properties. We begin by discussing materials based on proteins that have well-defined three-dimensional structures, focusing specifically on elastin- and silk-like peptides. We then explore the newer field of materials based on intrinsically disordered proteins, using nucleoporin and neurofilament proteins as case studies. A key theme throughout the review is that specific environmental stimuli can trigger protein conformational changes, which in turn can alter macroscopic material properties and function.
Collapse
Affiliation(s)
- Nithya Srinivasan
- Department of Bioengineering, University of California, Berkeley, CA, USA
| | | |
Collapse
|
12
|
Miyoshi H, Adachi T, Ju J, Lee SM, Cho DJ, Ko JS, Uchida G, Yamagata Y. Characteristics of motility-based filtering of adherent cells on microgrooved surfaces. Biomaterials 2011; 33:395-401. [PMID: 22019118 DOI: 10.1016/j.biomaterials.2011.09.094] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2011] [Accepted: 09/29/2011] [Indexed: 10/16/2022]
Abstract
Topographical features are known to physically affect cell behavior and are expected to have great potential for non-invasive control of such behavior. To provide a design concept of a microstructured surface for elaborate non-invasive control of cell migration, we systematically analyzed the effect of microgrooves on cell migration. We fabricated silicon microstructured surfaces covered with SiO(2) with microgrooves of various sizes, and characterized the behavior of cells moving from the flat surface to the grooved surface. The intersecting microgrooves with well-defined groove width absorbed or repelled cells precisely according to the angle of approach of the cell to the boundary with the grooved surface. This filtering process was explained by the difference in the magnitude of the lamellar dragging effect resulting from the number of the grooves interacting with the lamella of the cell. This study provides a framework to tailor the microgrooved surface for non-invasive control of cell migration with label-free detection of a specific property of the target cells. This should offer significant benefits to biomedical research and applications.
Collapse
Affiliation(s)
- Hiromi Miyoshi
- Ultrahigh Precision Fabrication Team, Advanced Science Institute, VCAD System Research Program, RIKEN (The Institute of Physical and Chemical Research), 2-1 Hirosawa, Wako-shi, Saitama 351-0198, Japan.
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Cozad MJ, Bachman SL, Grant SA. Assessment of decellularized porcine diaphragm conjugated with gold nanomaterials as a tissue scaffold for wound healing. J Biomed Mater Res A 2011; 99:426-34. [PMID: 21887737 DOI: 10.1002/jbm.a.33182] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2011] [Revised: 05/11/2011] [Accepted: 05/19/2011] [Indexed: 01/22/2023]
Abstract
One million Americans suffer from chronic wounds every year with diabetics and older populations representing the majority. Mechanisms that may be responsible for the reduced healing response in these patients include reduction in growth factors or vascularization and an increase in free radical levels. The focus of this study was to develop a biocompatible gold/porcine diaphragm scaffold capable of sustaining fibroblast attachment and proliferation which was measured using viability and dsDNA assays. The free radical scavenging properties, as measured by ROS assays, were also investigated as a mechanism for improving the wound environment. Results indicated 69-89% viability for gold nanoparticle (AuNP) scaffolds and 51-74% for gold nanorod (AuNR) scaffolds as compared to 100% for decellularized scaffolds and 77% for crosslinked scaffolds. All scaffolds exhibited good cell attachment while AuNP-1X scaffolds showed the greatest cell proliferation with a 74% increase in dsDNA content from Day 3 to 7. AuNP-2X and AuNP-4X scaffolds generated higher levels of free radicals with AuNP-4X generating over twice as much as decellularized scaffolds. This study suggests the capability for gold/porcine diaphragm scaffolds to enhance cell proliferation while the modification of free radical generation appears to be dependent on nanomaterial shape and concentration.
Collapse
Affiliation(s)
- Matthew J Cozad
- Department of Biological Engineering, University of Missouri, Columbia, Missouri, USA
| | | | | |
Collapse
|
14
|
Abstract
One of the central challenges in cardiac tissue engineering is the control of the assembly and organization of functional cardiac tissue. Maintenance of a three-dimensional tissue architecture is key to myocardial function in vivo, and a variety of studies hint that provision of topological cues within scaffolds can facilitate the engineering of functional myocardial tissue by promoting this architecture. To explore this possibility in an isolated and well-defined fashion, we have designed scaffolds of polydimethylsiloxane (PDMS) with microtopographic pillars ("micropegs") to provide cells with defined structures with which to interact in three dimensions. We show that these surfaces permit HL-1 cardiomyocytes to grow, form myofibrillar structures and cell-cell adhesions, and beat spontaneously. Additionally, the cells and their nuclei interact with the full length of the micropegs, indicating that the micropegs promote a three-dimensional cytoarchitecture in the context of a two-dimensional scaffold. We also show that the number of cells interacting with a micropeg can be controlled by manipulating incubation time, micropeg spatial arrangement, or micropeg diameter. Western blots reveal that the expression of the junctional markers N-cadherin and connexin 43 is upregulated in the presence of specific arrangements of micropegs, suggesting that micropegs can enhance cardiomyocyte function. Together, these data show that microtopography can be used to provide three-dimensional adhesion and control the assembly of functional cardiac tissue on a two-dimensional surface.
Collapse
Affiliation(s)
- Anuj A Patel
- The UC Berkeley - UCSF Graduate Program in Bioengineering, USA
| | | | | |
Collapse
|
15
|
Ayala P, Desai TA. Integrin α3 blockade enhances microtopographical down-regulation of α-smooth muscle actin: role of microtopography in ECM regulation. Integr Biol (Camb) 2011; 3:733-41. [PMID: 21666923 DOI: 10.1039/c1ib00012h] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Development of functional engineered matrices for regenerative therapies can benefit from an understanding of how physical cues at the microscale affect cell behavior. In this work, we use microfabricated systems to study how stiffness and microscale topographical cues in the form of "micropegs" affect extracellular matrix synthesis. Previous work from our lab has shown that microtopographical cues in 2D and 3D systems decrease cellular proliferation and regulate matrix synthesis. In this work, the combined role of stiffness and topography on ECM synthesis is investigated in a 2D micropeg system. These studies show that fibroblasts cultured on polydimethylsiloxane (PDMS) substrates with micropegs have reduced expression of collagen type I (Col I) and collagen type VI (Col VI) compared to fibroblasts cultured on flat substrates. In addition, cells on micropegged substrates exhibit down-regulation of other important regulators of ECM synthesis such as α-smooth muscle actin (α-SMA), and integrin α3 (Int α3). Interestingly, this effect is dependent on the contractility and adhesion of the cells. When cultured in the presence of RhoA kinase (ROCK) and myosin light chain kinase (MLCK) inhibitors, no significant differences in the expression of collagen, α-SMA, Int α3, and TGFB1 are observed. Additionally, disruptions in cell adhesion prevent microtopographical regulation of ECM synthesis. When using an antibody to block the extracellular domain of Int α3, no differences in the expression of collagen are observed and blocking Int α3 results in enhanced down-regulation of α-SMA on the stiffer micropegged substrates. These findings demonstrate that regulation of extracellular matrix production by cells on a synthetic substrate can be guided via physical cues at the microscale, and add to the body of knowledge on the role of integrin-mediated mechanotransduction.
Collapse
Affiliation(s)
- Perla Ayala
- UCSF/UC Berkeley Joint Graduate Group in Bioengineering, USA
| | | |
Collapse
|
16
|
Helton KL, Ratner BD, Wisniewski NA. Biomechanics of the sensor-tissue interface-effects of motion, pressure, and design on sensor performance and the foreign body response-part I: theoretical framework. J Diabetes Sci Technol 2011; 5:632-46. [PMID: 21722578 PMCID: PMC3192629 DOI: 10.1177/193229681100500317] [Citation(s) in RCA: 93] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
The importance of biomechanics in glucose sensor function has been largely overlooked. This article is the first part of a two-part review in which we look beyond commonly recognized chemical biocompatibility to explore the biomechanics of the sensor-tissue interface as an important aspect of continuous glucose sensor biocompatibility. Part I provides a theoretical framework to describe how biomechanical factors such as motion and pressure (typically micromotion and micropressure) give rise to interfacial stresses, which affect tissue physiology around a sensor and, in turn, impact sensor performance. Three main contributors to sensor motion and pressure are explored: applied forces, sensor design, and subject/patient considerations. We describe how acute forces can temporarily impact sensor signal and how chronic forces can alter the foreign body response and inflammation around an implanted sensor, and thus impact sensor performance. The importance of sensor design (e.g., size, shape, modulus, texture) and specific implant location on the tissue response are also explored. In Part II: Examples and Application (a sister publication), examples from the literature are reviewed, and the application of biomechanical concepts to sensor design are described. We believe that adding biomechanical strategies to the arsenal of material compositions, surface modifications, drug elution, and other chemical strategies will lead to improvements in sensor biocompatibility and performance.
Collapse
|
17
|
Modulating malignant epithelial tumor cell adhesion, migration and mechanics with nanorod surfaces. Biomed Microdevices 2011; 13:89-95. [PMID: 20830527 DOI: 10.1007/s10544-010-9473-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
The failure of tumor stents used for palliative therapy is due in part to the adhesion of tumor cells to the stent surface. It is therefore desirable to develop approaches to weaken the adhesion of malignant tumor cells to surfaces. We have previously developed SiO₂ coated nanorods that resist the adhesion of normal endothelial cells and fibroblasts. The adhesion mechanisms in malignant tumor cells are significantly altered from normal cells; therefore, it is unclear if nanorods can similarly resist tumor cell adhesion. In this study, we show that the morphology of tumor epithelial cells cultured on nanorods is rounded compared to flat surfaces and associated with decreased cellular stiffness and non-muscle myosin II phosphorylation. Tumor cell viability and proliferation was unchanged on nanorods. Adherent cell numbers were significantly decreased while single tumor cell motility was increased on nanorods compared to flat surfaces. Together, these results suggest that nanorods can be used to weaken malignant tumor cell adhesion, and therefore potentially improve tumor stent performance.
Collapse
|
18
|
Micromechanical regulation in cardiac myocytes and fibroblasts: implications for tissue remodeling. Pflugers Arch 2011; 462:105-17. [PMID: 21308471 DOI: 10.1007/s00424-011-0931-8] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2010] [Revised: 01/25/2011] [Accepted: 01/25/2011] [Indexed: 10/18/2022]
Abstract
Cells of the myocardium are at home in one of the most mechanically dynamic environments in the body. At the cellular level, pulsatile stimuli of chamber filling and emptying are experienced as cyclic strains (relative deformation) and stresses (force per unit area). The intrinsic characteristics of tension-generating myocytes and fibroblasts thus have a continuous mechanical interplay with their extrinsic surroundings. This review explores the ways that the micromechanics at the scale of single cardiac myocytes and fibroblasts have been measured, modeled, and recapitulated in vitro in the context of adaptation. Both types of cardiac cells respond to externally applied strain, and many of the intracellular mechanosensing pathways have been identified with the careful manipulation of experimental variables. In addition to strain, the extent of loading in myocytes and fibroblasts is also regulated by cues from the microenvironment such as substrate surface chemistry, stiffness, and topography. Combinations of these structural cues in three dimensions are needed to mimic the micromechanical complexity derived from the extracellular matrix of the developing, healthy, or pathophysiologic heart. An understanding of cardiac cell micromechanics can therefore inform the design and composition of tissue engineering scaffolds or stem cell niches for future applications in regenerative medicine.
Collapse
|
19
|
You MH, Kwak MK, Kim DH, Kim K, Levchenko A, Kim DY, Suh KY. Synergistically enhanced osteogenic differentiation of human mesenchymal stem cells by culture on nanostructured surfaces with induction media. Biomacromolecules 2010; 11:1856-62. [PMID: 20568737 DOI: 10.1021/bm100374n] [Citation(s) in RCA: 99] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
We have examined the effects of surface nanotopography on in vitro osteogenesis of human mesenchymal stem cells (hMSCs). UV-assisted capillary force lithography was employed to fabricate a scalable (4x5 cm), well-defined nanostructured substrate of a UV curable polyurethane polymer with dots (150, 400, 600 nm diameter) and lines (150, 400, 600 nm width). The influence of osteogenic differentiation of hMSCs was characterized at day 8 by alkaline phosphatase (ALP) assay, RT-PCR, and real-time PCR analysis. We found that hMSCs cultured on the nanostructured surfaces in osteogenic induction media showed significantly higher ALP activity compared to unpatterned PUA surface (control group). In particular, the hMSCs on the 400 nm dot pattern showed the highest level of ALP activity. Further investigation with real-time quantitative RT-PCR analysis demonstrated significantly higher expression of core binding factor 1 (Cbfa1), osteopontin (OP), and osteocalcin (OC) levels in hMSCs cultured on the 400 nm dot pattern in osteogenic induction media. These findings suggest that surface nanotopography can enhance osteogenic differentiation synergistically with biochemical induction substance.
Collapse
Affiliation(s)
- Mi-Hyeon You
- Department of Veterinary Pathology, Seoul National University, Seoul 151-742, Korea
| | | | | | | | | | | | | |
Collapse
|
20
|
A novel method for assessing adherent single-cell stiffness in tension: design and testing of a substrate-based live cell functional imaging device. Biomed Microdevices 2010; 13:291-301. [DOI: 10.1007/s10544-010-9493-3] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|