1
|
Lai W, Li D, Wang J, Geng Q, Xia Y, Fu Y, Li W, Feng Y, Jin L, Yang R, Huang Z, Lin Y, Zhang H, Chen S, Chen L. Exhaled breath is feasible for mild cognitive impairment detection: A diagnostic study with portable micro-gas chromatography. J Alzheimers Dis 2025; 104:751-762. [PMID: 39956982 DOI: 10.1177/13872877251319553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2025]
Abstract
BackgroundMild cognitive impairment (MCI) is an important prodromal stage of Alzheimer's disease (AD), affecting 69 million individuals worldwide. At present, there is a lack of a community-applicable tool for MCI screening. Exhaled breath volatile organic compounds (VOCs) have been used to distinguish MCI from cognitively normal (CN) individuals only in small sample size studies and the efficacy has not been compared with blood biomarkers.ObjectiveThis diagnostic study aimed to assess the feasibility of using exhaled breath VOCs detection by a portable micro-gas chromatography (μGC) device as a screening tool to discriminate MCI from CN individuals in a community population.MethodsA detection model was developed and optimized from five distinct machine learning algorithms based on the differential VOCs between 240 MCI and 241 CN individuals. Among these 481 participants, five plasma biomarkers were measured in 397 individuals (166 MCI and 231 CN).ResultsThe final model (481 individuals) incorporating eight differential VOCs showed good performance with an area under the receiver-operating characteristic curve (AUC) of 0.84 (95% confidence interval (95% CI): 0.83-0.85). The AUC of the VOC model (0.80, 95% CI: 0.69-0.90) was higher than that of the plasma model (0.77, 95% CI: 0.65-0.88) (397 individuals).ConclusionsThe detection of exhaled breath VOCs by a portable μGC device is feasible for MCI screening in community populations, potentially facilitating early detection and intervention strategies for individuals at high risk.
Collapse
Affiliation(s)
- Wanlin Lai
- Department of Neurology, West China Hospital of Sichuan University, Chengdu, Sichuan, P. R. China
| | - Debo Li
- Department of Neurology, West China Hospital of Sichuan University, Chengdu, Sichuan, P. R. China
| | - Junqi Wang
- Jingjinji National Center of Technology Innovation, Beijing, P. R. China
- GBA Institute of Collaborative Innovation, Sino-Singapore Guangzhou Knowledge City, Guangzhou, Guangdong, P. R. China
| | - Qian Geng
- GBA Institute of Collaborative Innovation, Sino-Singapore Guangzhou Knowledge City, Guangzhou, Guangdong, P. R. China
| | - Yilin Xia
- Department of Neurology, West China Hospital of Sichuan University, Chengdu, Sichuan, P. R. China
| | - Yutong Fu
- Department of Neurology, West China Hospital of Sichuan University, Chengdu, Sichuan, P. R. China
| | - Wanling Li
- Department of Neurology, West China Hospital of Sichuan University, Chengdu, Sichuan, P. R. China
| | - Yong Feng
- GBA Institute of Collaborative Innovation, Sino-Singapore Guangzhou Knowledge City, Guangzhou, Guangdong, P. R. China
| | - Ling Jin
- Department of Neurology, West China Hospital of Sichuan University, Chengdu, Sichuan, P. R. China
| | - Ruiqi Yang
- Department of Neurology, West China Hospital of Sichuan University, Chengdu, Sichuan, P. R. China
| | - Zijie Huang
- Department of Neurology, West China Hospital of Sichuan University, Chengdu, Sichuan, P. R. China
| | - Yuhang Lin
- GBA Institute of Collaborative Innovation, Sino-Singapore Guangzhou Knowledge City, Guangzhou, Guangdong, P. R. China
| | - Han Zhang
- GBA Institute of Collaborative Innovation, Sino-Singapore Guangzhou Knowledge City, Guangzhou, Guangdong, P. R. China
| | - Sitong Chen
- GBA Institute of Collaborative Innovation, Sino-Singapore Guangzhou Knowledge City, Guangzhou, Guangdong, P. R. China
| | - Lei Chen
- Department of Neurology, West China Hospital of Sichuan University, Chengdu, Sichuan, P. R. China
- Joint Research Institution of Altitude Health, West China Hospital of Sichuan University, Chengdu, Sichuan, P. R. China
| |
Collapse
|
2
|
Vuong C, Brinkman P, Heijboer H, Nur E, Eckhardt CL, Terheggen-Lagro SWJ, Biemond BJ, Maitland-van der Zee AH, Fijnvandraat K. Exhaled breath analysis during vaso-occlusive events in sickle cell disease. Br J Haematol 2025; 206:781-784. [PMID: 39676321 DOI: 10.1111/bjh.19942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2024] [Accepted: 11/25/2024] [Indexed: 12/17/2024]
Affiliation(s)
- C Vuong
- Department of Paediatric Haematology, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - P Brinkman
- Department of Pulmonary Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - H Heijboer
- Department of Paediatric Haematology, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - E Nur
- Department of Clinical Haematology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - C L Eckhardt
- Department of Paediatric Haematology, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - S W J Terheggen-Lagro
- Department of Paediatric Pulmonology and Allergy, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - B J Biemond
- Department of Clinical Haematology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - A H Maitland-van der Zee
- Department of Pulmonary Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - K Fijnvandraat
- Department of Paediatric Haematology, Emma Children's Hospital, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
3
|
Al-Difaie ZJJ, Scheepers MHMC, Engelen SME, Lubbers T, Havekes B, Bouvy ND. Volatile organic compounds in exhaled breath, blood, and urine detected in patients with thyroid carcinoma using gas chromatography-ion mobility spectrometry -a pilot study. J Breath Res 2024; 19:016009. [PMID: 39437815 DOI: 10.1088/1752-7163/ad89ef] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Accepted: 10/22/2024] [Indexed: 10/25/2024]
Abstract
The differentiation between malignant and benign thyroid nodules represents a significant challenge for clinicians globally. The identification of volatile organic compounds (VOCs) has emerged as a novel approach in the field of cancer diagnosis. This prospective pilot study aims to identify VOCs in exhaled breath, blood, and urine that can differentiate benign from malignant thyroid nodules using gas chromatography-ion mobility spectrometry (GC-IMS). Patients with thyroid nodules scheduled for surgery were enrolled at the Maastricht University Medical Center (MUMC+). Breath samples were analyzed using a BreathSpec GC-IMS machine (G.A.S. Dortmund, Germany), specifically designed for breath analysis. All blood and urine samples were analyzed using a separate GC-IMS device, the FlavourSpec® (G.A.S., Dortmund, Germany). In this proof-of-concept study, 70 consecutive patients undergoing thyroid surgery at MUMC+ were included. Of these patients, 29 were confirmed to have thyroid cancer after surgical resection. The overall analysis did not reveal statistically significant differences in VOCs in breath, urine and blood, between patients with benign and malignant thyroid cancer. This proof-of-concept study demonstrated that GC-IMS could not effectively differentiate between the VOC profiles of malignant and benign thyroid nodules. However, due to the small sample size of this study, larger prospective studies are needed to investigate the potential of using VOCs to distinguish between benign and malignant thyroid nodules. Additionally, future research should focus on identifying potential confounding factors that may influence patient VOC profiles. (NCT04883294).
Collapse
Affiliation(s)
- Zaid J J Al-Difaie
- GROW School for Oncology and Developmental Biology, Maastricht University, Maastricht, The Netherlands
| | - Max H M C Scheepers
- GROW School for Oncology and Developmental Biology, Maastricht University, Maastricht, The Netherlands
| | - Sanne M E Engelen
- Department of Surgery, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Tim Lubbers
- GROW School for Oncology and Developmental Biology, Maastricht University, Maastricht, The Netherlands
- Department of Surgery, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Bas Havekes
- Department of Internal Medicine, Division of Endocrinology, Maastricht University Medical Center, Maastricht, The Netherlands
- NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands
| | - Nicole D Bouvy
- GROW School for Oncology and Developmental Biology, Maastricht University, Maastricht, The Netherlands
- Department of Surgery, Maastricht University Medical Center, Maastricht, The Netherlands
| |
Collapse
|
4
|
Phillips M, Bevers TB, Larsen LH, Pappas N, Pathak S. BREATH TEST TO DETECT WOMEN AT LOW RISK FOR BREAST CANCER: POTENTIAL CLINICAL AND ECONOMIC BENEFITS. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2024:2024.10.09.24315190. [PMID: 39417144 PMCID: PMC11483023 DOI: 10.1101/2024.10.09.24315190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 10/19/2024]
Abstract
Background A breath test for volatile organic compounds has identified biomarkers associated with breast cancer. We evaluated the potential clinical and economic benefits of a breath test to detect women at low risk for breast cancer by comparing its negative predictive value (NPV) to the NPV of screening mammography. Methods Sensitivity and specificity values for screening mammography were obtained from the Food & Drug Administration Mammography Quality Standards Act; Amendments to Part 900 Regulations Docket No. FDA-2013-N-0134. The high values were sensitivity = 79.0%, specificity = 88.9% and the low values were sensitivity = 66.0%, specificity = 88.9%. In two previous studies of 771 women undergoing mammography, breath testing identified breast cancer with sensitivity=84% and specificity = 68.6% in 178 asymptomatic women, and sensitivity=82% and specificity = 77% in 593 who were symptomatic. These values were projected to a hypothetical screening population of 100,000 asymptomatic women with average breast cancer prevalence of 450/100,000, in order to estimate the NPV and PPV (positive predictive value) for breath testing and screening mammography respectively. Results Breath test in asymptomatic women: NPV = 99.895% and PPV = 1.19%; in symptomatic women: NPV = 99.895% and PPV = 1.59%. For screening mammography, NPV = 99.83% and PPV = 2.82% (low values), increasing to NPV= 99.89% and PPV = 3.12% (high values). A negative breath test identified 68.3% of the screening population as having low risk of breast cancer, with NPV similar to mammography. Based on Medicare reimbursement rates, elimination of mammography in women with a negative breath test could reduce the annual cost of breast cancer screening by 38.9. Conclusions In a hypothetical screening population, a negative breath test ruled out breast cancer with the same accuracy as a negative mammogram. A screening breath test could potentially eliminate the need for two thirds of all mammograms and reduce the costs of screening without increasing the risk of false-negative findings. If applied in clinical practice, this approach could potentially reduce the costs and burdens of breast cancer screening services, and benefit women by lessening the discomfort, anxiety, radiation exposure, and costs associated with mammography.
Collapse
Affiliation(s)
- Michael Phillips
- Menssana Research Inc, 1 Horizon Road, Suite 1415, Fort Lee, NJ 07024
- Department of Medicine, New York Medical College, Valhalla, NY
| | | | | | | | - Sonali Pathak
- Menssana Research Inc, 1 Horizon Road, Suite 1415, Fort Lee, NJ 07024
| |
Collapse
|
5
|
Fan X, Zhong R, Liang H, Zhong Q, Huang H, He J, Chen Y, Wang Z, Xie S, Jiang Y, Lin Y, Chen S, Liang W, He J. Exhaled VOC detection in lung cancer screening: a comprehensive meta-analysis. BMC Cancer 2024; 24:775. [PMID: 38937687 PMCID: PMC11212189 DOI: 10.1186/s12885-024-12537-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2024] [Accepted: 06/18/2024] [Indexed: 06/29/2024] Open
Abstract
BACKGROUND Lung cancer (LC), characterized by high incidence and mortality rates, presents a significant challenge in oncology. Despite advancements in treatments, early detection remains crucial for improving patient outcomes. The accuracy of screening for LC by detecting volatile organic compounds (VOCs) in exhaled breath remains to be determined. METHODS Our systematic review, following PRISMA guidelines and analyzing data from 25 studies up to October 1, 2023, evaluates the effectiveness of different techniques in detecting VOCs. We registered the review protocol with PROSPERO and performed a systematic search in PubMed, EMBASE and Web of Science. Reviewers screened the studies' titles/abstracts and full texts, and used QUADAS-2 tool for quality assessment. Then performed meta-analysis by adopting a bivariate model for sensitivity and specificity. RESULTS This study explores the potential of VOCs in exhaled breath as biomarkers for LC screening, offering a non-invasive alternative to traditional methods. In all studies, exhaled VOCs discriminated LC from controls. The meta-analysis indicates an integrated sensitivity and specificity of 85% and 86%, respectively, with an AUC of 0.93 for VOC detection. We also conducted a systematic analysis of the source of the substance with the highest frequency of occurrence in the tested compounds. Despite the promising results, variability in study quality and methodological challenges highlight the need for further research. CONCLUSION This review emphasizes the potential of VOC analysis as a cost-effective, non-invasive screening tool for early LC detection, which could significantly improve patient management and survival rates.
Collapse
Affiliation(s)
- Xianzhe Fan
- Department of Thoracic Surgery and Oncology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, Guangdong, China
| | - Ran Zhong
- Department of Thoracic Surgery and Oncology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, Guangdong, China
| | - Hengrui Liang
- Department of Thoracic Surgery and Oncology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, Guangdong, China
| | - Qiu Zhong
- Department of Thoracic Surgery and Oncology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, Guangdong, China
| | - Hongtai Huang
- Department of Thoracic Surgery and Oncology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, Guangdong, China
| | - Juan He
- Department of Thoracic Surgery and Oncology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, Guangdong, China
| | - Yang Chen
- Department of Thoracic Surgery and Oncology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, Guangdong, China
| | - Zixun Wang
- Department of Thoracic Surgery and Oncology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, Guangdong, China
| | - Songlin Xie
- Department of Thoracic Surgery and Oncology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, Guangdong, China
| | - Yu Jiang
- Department of Thoracic Surgery and Oncology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, Guangdong, China
| | - Yuechun Lin
- Department of Thoracic Surgery and Oncology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, Guangdong, China
| | - Sitong Chen
- ChromX Health Co., Ltd, Guangzhou, Guangdong, China
| | - Wenhua Liang
- Department of Thoracic Surgery and Oncology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, Guangdong, China.
- Department of Thoracic Surgery and Oncology, State Key Laboratory of Respiratory Disease, National Center for Respiratory Medicine, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, Guangdong, 510120, China.
| | - Jianxing He
- Department of Thoracic Surgery and Oncology, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou, 510120, Guangdong, China.
| |
Collapse
|
6
|
Li L, Wen X, Li X, Yan Y, Wang J, Zhao X, Tian Y, Ling R, Duan Y. Identifying potential breath biomarkers for early diagnosis of papillary thyroid cancer based on solid-phase microextraction gas chromatography-high resolution mass spectrometry with metabolomics. Metabolomics 2024; 20:59. [PMID: 38773019 DOI: 10.1007/s11306-024-02119-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 04/20/2024] [Indexed: 05/23/2024]
Abstract
INTRODUCTION Thyroid cancer incidence rate has increased substantially worldwide in recent years. Fine needle aspiration biopsy (FNAB) is currently the golden standard of thyroid cancer diagnosis, which however, is invasive and costly. In contrast, breath analysis is a non-invasive, safe and simple sampling method combined with a promising metabolomics approach, which is suitable for early cancer diagnosis in high volume population. OBJECTIVES This study aims to achieve a more comprehensive and definitive exhaled breath metabolism profile in papillary thyroid cancer patients (PTCs). METHODS We studied both end-tidal and mixed expiratory breath, solid-phase microextraction gas chromatography coupled with high resolution mass spectrometry (SPME-GC-HRMS) was used to analyze the breath samples. Multivariate combined univariate analysis was applied to identify potential breath biomarkers. RESULTS The biomarkers identified in end-tidal and mixed expiratory breath mainly included alkanes, olefins, enols, enones, esters, aromatic compounds, and fluorine and chlorine containing organic compounds. The area under the curve (AUC) values of combined biomarkers were 0.974 (sensitivity: 96.1%, specificity: 90.2%) and 0.909 (sensitivity: 98.0%, specificity: 74.5%), respectively, for the end-tidal and mixed expiratory breath, indicating of reliability of the sampling and analysis method CONCLUSION: This work not only successfully established a standard metabolomic approach for early diagnosis of PTC, but also revealed the necessity of using both the two breath types for comprehensive analysis of the biomarkers.
Collapse
Affiliation(s)
- Lan Li
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an, 710069, Shaanxi, China
| | - Xinxin Wen
- Department of Thyroid, Breast and Vascular Surgery, Xijing Hospital, Air Force Military Medical University, Xi'an, 710032, Shaanxi, China
| | - Xian Li
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an, 710069, Shaanxi, China
| | - Yaqi Yan
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an, 710069, Shaanxi, China
| | - Jiayu Wang
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an, 710069, Shaanxi, China
| | - Xuyang Zhao
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an, 710069, Shaanxi, China
| | - Yonghui Tian
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an, 710069, Shaanxi, China
| | - Rui Ling
- Department of Thyroid, Breast and Vascular Surgery, Xijing Hospital, Air Force Military Medical University, Xi'an, 710032, Shaanxi, China.
| | - Yixiang Duan
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an, 710069, Shaanxi, China.
| |
Collapse
|
7
|
Lilien TA, Brinkman P, Fenn DW, van Woensel JBM, Bos LDJ, Bem RA. Breath Markers of Oxidative Stress in Children with Severe Viral Lower Respiratory Tract Infection. Am J Respir Cell Mol Biol 2024; 70:392-399. [PMID: 38315815 DOI: 10.1165/rcmb.2023-0349oc] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Accepted: 02/05/2024] [Indexed: 02/07/2024] Open
Abstract
Severe viral lower respiratory tract infection (LRTI), resulting in both acute and long-term pulmonary disease, constitutes a substantial burden among young children. Viral LRTI triggers local oxidative stress pathways by infection and inflammation, and supportive care in the pediatric intensive care unit may further aggravate oxidative injury. The main goal of this exploratory study was to identify and monitor breath markers linked to oxidative stress in children over the disease course of severe viral LRTI. Exhaled breath was sampled during invasive ventilation, and volatile organic compounds (VOCs) were analyzed using gas chromatography and mass spectrometry. VOCs were selected in an untargeted principal component analysis and assessed for change over time. In addition, identified VOCs were correlated with clinical parameters. Seventy breath samples from 21 patients were analyzed. A total of 15 VOCs were identified that contributed the most to the explained variance of breath markers. Of these 15 VOCs, 10 were previously linked to pathways of oxidative stress. Eight VOCs, including seven alkanes and methyl alkanes, significantly decreased from the initial phase of ventilation to the day of extubation. No correlation was observed with the administered oxygen dose, whereas six VOCs showed a poor to strong positive correlation with driving pressure. In this prospective study of children with severe viral LRTI, the majority of VOCs that were most important for the explained variance mirrored clinical improvement. These breath markers could potentially help monitor the pulmonary oxidative status in these patients, but further research with other objective measures of pulmonary injury is required.
Collapse
Affiliation(s)
- Thijs A Lilien
- Department of Pediatric Intensive Care Medicine, Emma Children's Hospital
- Amsterdam Reproduction and Development Research Institute, Amsterdam, the Netherlands
| | | | | | - Job B M van Woensel
- Department of Pediatric Intensive Care Medicine, Emma Children's Hospital
- Amsterdam Reproduction and Development Research Institute, Amsterdam, the Netherlands
| | - Lieuwe D J Bos
- Department of Pulmonology, and
- Department of Intensive Care Medicine, Amsterdam UMC location University of Amsterdam, Amsterdam, the Netherlands; and
| | - Reinout A Bem
- Department of Pediatric Intensive Care Medicine, Emma Children's Hospital
- Amsterdam Reproduction and Development Research Institute, Amsterdam, the Netherlands
| |
Collapse
|
8
|
Padawer D, Qadan A, Karameh M, Darawshy F, Laor A, Banker S, Fridlender ZG. Breath of Health: spectroscopy-based breath test for the detection of SARS-CoV-2. Infect Dis (Lond) 2024; 56:376-383. [PMID: 38424673 DOI: 10.1080/23744235.2024.2313020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Accepted: 01/27/2024] [Indexed: 03/02/2024] Open
Abstract
BACKGROUND Nucleic acid amplification tests (NAAT) are considered the gold standard for COVID-19 diagnosis. These tests require professional manpower and equipment, long processing and swab sampling which is unpleasant to the patients. Several volatile organic compounds (VOCs) have been identified in the breath of COVID-19 patients. Detection of these VOCs using a breath test could help rapidly identify COVID-19 patients. OBJECTIVE Assess the accuracy of 'Breath of Health' (BOH) COVID-19 Fourier-transform infra-red (FTIR) Spectroscopy-based breath test. METHODS Breath samples from patients with or without symptoms suggestive for COVID-19 who had NAAT results were collected using Tedlar bags and were blindly analysed using BOH FTIR spectroscopy. BOH Measures several VOCs simultaneously and differentiating positive and negative results. BOH results were compared to NAAT results as gold standard. RESULTS Breath samples from 531 patients were analysed. The sensitivity of BOH breath test was found to be 79.5% and specificity was 87.2%. Positive predictive value (PPV) was 74.7% and negative predictive value (NPV) 90.0%. Calculated accuracy rate was 84.8% and area under the curve 0.834. Subgroup analysis revealed that the NPV of patients without respiratory symptoms was superior over the NPV of symptomatic patients (94.7% vs 80.7%, P-value < 0.0001) and PPV of patients with respiratory symptoms outranks the PPV of individuals without symptoms (85.3% vs 69.2%, P-value 0.0196). CONCLUSION We found BOH COVID-19 breath test to be a patient-friendly, rapid, non-invasive diagnostic test with high accuracy rate and NPV that could efficiently rule out COVID-19 especially among individuals with low pre-test probability.
Collapse
Affiliation(s)
- Dan Padawer
- Institute of Pulmonary Medicine, Hadassah Medical Center, Jerusalem, Israel
- Department of Internal Medicine D, Hadassah Medical Center, Jerusalem, Israel
- Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel
| | - Abed Qadan
- Department of Internal Medicine D, Hadassah Medical Center, Jerusalem, Israel
- Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel
| | - Mutaz Karameh
- Department of Internal Medicine D, Hadassah Medical Center, Jerusalem, Israel
- Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel
- Heart Institute, Hadassah Medical Center, Jerusalem, Israel
| | - Fares Darawshy
- Institute of Pulmonary Medicine, Hadassah Medical Center, Jerusalem, Israel
- Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel
| | - Arie Laor
- Breath of Health Ltd, Rehovot, Israel
| | | | - Zvi G Fridlender
- Institute of Pulmonary Medicine, Hadassah Medical Center, Jerusalem, Israel
- Department of Internal Medicine D, Hadassah Medical Center, Jerusalem, Israel
- Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel
| |
Collapse
|
9
|
Picciariello A, Dezi A, Vincenti L, Spampinato MG, Zang W, Riahi P, Scott J, Sharma R, Fan X, Altomare DF. Colorectal Cancer Diagnosis through Breath Test Using a Portable Breath Analyzer-Preliminary Data. SENSORS (BASEL, SWITZERLAND) 2024; 24:2343. [PMID: 38610554 PMCID: PMC11014225 DOI: 10.3390/s24072343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2024] [Revised: 03/28/2024] [Accepted: 04/05/2024] [Indexed: 04/14/2024]
Abstract
Screening methods available for colorectal cancer (CRC) to date are burdened by poor reliability and low patient adherence and compliance. An altered pattern of volatile organic compounds (VOCs) in exhaled breath has been proposed as a non-invasive potential diagnostic tool for distinguishing CRC patients from healthy controls (HC). The aim of this study was to evaluate the reliability of an innovative portable device containing a micro-gas chromatograph in enabling rapid, on-site CRC diagnosis through analysis of patients' exhaled breath. In this prospective trial, breath samples were collected in a tertiary referral center of colorectal surgery, and analysis of the chromatograms was performed by the Biomedical Engineering Department. The breath of patients with CRC and HC was collected into Tedlar bags through a Nafion filter and mouthpiece with a one-way valve. The breath samples were analyzed by an automated portable gas chromatography device. Relevant volatile biomarkers and discriminant chromatographic peaks were identified through machine learning, linear discriminant analysis and principal component analysis. A total of 68 subjects, 36 patients affected by histologically proven CRC with no evidence of metastases and 32 HC with negative colonoscopies, were enrolled. After testing a training set (18 CRC and 18 HC) and a testing set (18 CRC and 14 HC), an overall specificity of 87.5%, sensitivity of 94.4% and accuracy of 91.2% in identifying CRC patients was found based on three VOCs. Breath biopsy may represent a promising non-invasive method of discriminating CRC patients from HC.
Collapse
Affiliation(s)
| | - Agnese Dezi
- Department of Precision and Regenerative Medicine and Ionian Area and Interdepartmental Research Center for Pelvic Floor Diseases (CIRPAP), University Aldo Moro of Bari, 70124 Bari, Italy
| | - Leonardo Vincenti
- Surgical Unit, IRCCS de Bellis, Castellana Grotte, 70013 Bari, Italy;
| | | | - Wenzhe Zang
- Biomedical Engineering Department, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA; (W.Z.); (J.S.); (R.S.); (X.F.)
| | - Pamela Riahi
- Biomedical Engineering Department, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA; (W.Z.); (J.S.); (R.S.); (X.F.)
| | - Jared Scott
- Biomedical Engineering Department, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA; (W.Z.); (J.S.); (R.S.); (X.F.)
| | - Ruchi Sharma
- Biomedical Engineering Department, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA; (W.Z.); (J.S.); (R.S.); (X.F.)
| | - Xudong Fan
- Biomedical Engineering Department, University of Michigan, 1101 Beal Ave., Ann Arbor, MI 48109, USA; (W.Z.); (J.S.); (R.S.); (X.F.)
| | - Donato F. Altomare
- Department of Precision and Regenerative Medicine and Ionian Area and Interdepartmental Research Center for Pelvic Floor Diseases (CIRPAP), University Aldo Moro of Bari, 70124 Bari, Italy
| |
Collapse
|
10
|
Lilien TA, Fenn DW, Brinkman P, Hagens LA, Smit MR, Heijnen NFL, van Woensel JBM, Bos LDJ, Bem RA. HS-GC-MS analysis of volatile organic compounds after hyperoxia-induced oxidative stress: a validation study. Intensive Care Med Exp 2024; 12:14. [PMID: 38345723 PMCID: PMC10861410 DOI: 10.1186/s40635-024-00600-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2023] [Accepted: 01/26/2024] [Indexed: 02/15/2024] Open
Abstract
BACKGROUND Exhaled volatile organic compounds (VOCs), particularly hydrocarbons from oxidative stress-induced lipid peroxidation, are associated with hyperoxia exposure. However, important heterogeneity amongst identified VOCs and concerns about their precise pathophysiological origins warrant translational studies assessing their validity as a marker of hyperoxia-induced oxidative stress. Therefore, this study sought to examine changes in VOCs previously associated with the oxidative stress response in hyperoxia-exposed lung epithelial cells. METHODS A549 alveolar epithelial cells were exposed to hyperoxia for 24 h, or to room air as normoxia controls, or hydrogen peroxide as oxidative-stress positive controls. VOCs were sampled from the headspace, analysed by gas chromatography coupled with mass spectrometry and compared by targeted and untargeted analyses. A secondary analysis of breath samples from a large cohort of critically ill adult patients assessed the association of identified VOCs with clinical oxygen exposure. RESULTS Following cellular hyperoxia exposure, none of the targeted VOCs, previously proposed as breath markers of oxidative stress, were increased, and decane was significantly decreased. Untargeted analysis did not reveal novel identifiable hyperoxia-associated VOCs. Within the clinical cohort, three previously proposed breath markers of oxidative stress, hexane, octane, and decane had no real diagnostic value in discriminating patients exposed to hyperoxia. CONCLUSIONS Hyperoxia exposure of alveolar epithelial cells did not result in an increase in identifiable VOCs, whilst VOCs previously linked to oxidative stress were not associated with oxygen exposure in a cohort of critically ill patients. These findings suggest that the pathophysiological origin of previously proposed breath markers of oxidative stress is more complex than just oxidative stress from hyperoxia at the lung epithelial cellular level.
Collapse
Affiliation(s)
- Thijs A Lilien
- Department of Paediatric Intensive Care Medicine, Emma Children's Hospital, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands.
- Laboratory of Experimental Intensive Care and Anaesthesiology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands.
| | - Dominic W Fenn
- Laboratory of Experimental Intensive Care and Anaesthesiology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
- Department of Pulmonary Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
| | - Paul Brinkman
- Department of Pulmonary Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
| | - Laura A Hagens
- Department of Intensive Care Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
| | - Marry R Smit
- Department of Intensive Care Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
| | - Nanon F L Heijnen
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Job B M van Woensel
- Department of Paediatric Intensive Care Medicine, Emma Children's Hospital, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
| | - Lieuwe D J Bos
- Laboratory of Experimental Intensive Care and Anaesthesiology, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
- Department of Intensive Care Medicine, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
| | - Reinout A Bem
- Department of Paediatric Intensive Care Medicine, Emma Children's Hospital, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
- Amsterdam Reproduction and Development Research Institute, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands
| |
Collapse
|
11
|
Gaye O, Fall CB, Jalloh M, Faye B, Jobin M, Cussenot O. Detection of urological cancers by the signature of organic volatile compounds in urine, from dogs to electronic noses. Curr Opin Urol 2023; 33:437-444. [PMID: 37678152 DOI: 10.1097/mou.0000000000001128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/09/2023]
Abstract
PURPOSE OF REVIEW Urine volatile organic compound (VOC) testing for early detection of urological cancers is a minimally invasive and promising method. The objective of this review was to present the results of recently published work on this subject. RECENT FINDINGS Organic volatile compounds are produced through oxidative stress and peroxidation of cell membranes, and they are eliminated through feces, urine, and sweat. Studies looking for VOCs in urine for the diagnosis of urological cancers have mostly focused on bladder and prostate cancers. However, the number of patients included in the studies was small. The electronic nose was the most widely used means of detecting VOCs in urine for the detection of urological cancers. MOS sensors and pattern recognition machine learning were more used for the composition of electronic noses. Early detection of urological cancers by detection of VOCs in urine is a method with encouraging results with sensitivities ranging from 27 to 100% and specificities ranging from 72 to 94%. SUMMARY The olfactory signature of urine from patients with urological cancers is a promising biomarker for the early diagnosis of urological cancers. The electronic nose with its ability to recognize complex odors is an excellent alterative to canine diagnosis and analytical techniques. Nevertheless, additional research improving the technology of Enoses and the methodology of the studies is necessary for its implementation in daily clinical practice.
Collapse
Affiliation(s)
- Oumar Gaye
- Urology Department, Dalal Jamm Hospital
- University Cheikh Anta Diop
| | | | - Mohamed Jalloh
- Urology Department, Idrissa Pouye General Hospital, Dakar, Senegal
| | | | - Marc Jobin
- HEPIA, University of Applied Sciences of Western Switzerland (HES-SO), Genève, Switzerland
| | - Olivier Cussenot
- Nuffield Department of Surgical Sciences, University of Oxford, Oxford, UK
- CeRePP, Paris, France
| |
Collapse
|
12
|
Hagens LA, Heijnen NFL, Smit MR, Verschueren ARM, Nijsen TME, Geven I, Presură CN, Rietman R, Fenn DW, Brinkman P, Schultz MJ, Bergmans DCJJ, Schnabel RM, Bos LDJ. Octane in exhaled breath to diagnose acute respiratory distress syndrome in invasively ventilated intensive care unit patients. ERJ Open Res 2023; 9:00214-2023. [PMID: 37850212 PMCID: PMC10577595 DOI: 10.1183/23120541.00214-2023] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Accepted: 08/03/2023] [Indexed: 10/19/2023] Open
Abstract
Background The concentration of exhaled octane has been postulated as a reliable biomarker for acute respiratory distress syndrome (ARDS) using metabolomics analysis with gas chromatography and mass spectrometry (GC-MS). A point-of-care (POC) breath test was developed in recent years to accurately measure octane at the bedside. The aim of the present study was to validate the diagnostic accuracy of exhaled octane for ARDS using a POC breath test in invasively ventilated intensive care unit (ICU) patients. Methods This was an observational cohort study of consecutive patients receiving invasive ventilation for at least 24 h, recruited in two university ICUs. GC-MS and POC breath tests were used to quantify the exhaled octane concentration. ARDS was assessed by three experts following the Berlin definition and used as the reference standard. The area under the receiver operating characteristic curve (AUC) was used to assess diagnostic accuracy. Results 519 patients were included and 190 (37%) fulfilled the criteria for ARDS. The median (interquartile range) concentration of octane using the POC breath test was not significantly different between patients with ARDS (0.14 (0.05-0.37) ppb) and without ARDS (0.11 (0.06-0.26) ppb; p=0.64). The AUC for ARDS based on the octane concentration in exhaled breath using the POC breath test was 0.52 (95% CI 0.46-0.57). Analysis of exhaled octane with GC-MS showed similar results. Conclusions Octane in exhaled breath has insufficient diagnostic accuracy for ARDS. This disqualifies the use of octane as a biomarker in the diagnosis of ARDS and challenges most of the research performed up to now in the field of exhaled breath metabolomics.
Collapse
Affiliation(s)
- Laura A Hagens
- Department of Intensive Care, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
| | - Nanon F L Heijnen
- Department of Intensive Care, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Marry R Smit
- Department of Intensive Care, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
| | | | - Tamara M E Nijsen
- Sleep and Respiratory Solutions, Philips Research, Eindhoven, The Netherlands
| | - Inge Geven
- Sleep and Respiratory Solutions, Philips Research, Eindhoven, The Netherlands
| | - Cristian N Presură
- Sleep and Respiratory Solutions, Philips Research, Eindhoven, The Netherlands
| | - Ronald Rietman
- Sleep and Respiratory Solutions, Philips Research, Eindhoven, The Netherlands
| | - Dominic W Fenn
- Department of Respiratory Medicine, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
- Laboratory of Experimental Intensive Care and Anesthesiology (LEICA), Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
| | - Paul Brinkman
- Department of Respiratory Medicine, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
| | - Marcus J Schultz
- Department of Intensive Care, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
- Mahidol-Oxford Tropical Medicine Research Unit (MORU), Mahidol University, Bangkok, Thailand
- Nuffield Department of Medicine, University of Oxford, Oxford, UK
| | - Dennis C J J Bergmans
- Department of Intensive Care, Maastricht University Medical Centre+, Maastricht, The Netherlands
- School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, Maastricht, The Netherlands
| | - Ronny M Schnabel
- Department of Intensive Care, Maastricht University Medical Centre+, Maastricht, The Netherlands
| | - Lieuwe D J Bos
- Department of Intensive Care, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
- Department of Respiratory Medicine, Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
- Laboratory of Experimental Intensive Care and Anesthesiology (LEICA), Amsterdam UMC location University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
13
|
Mezmale L, Leja M, Lescinska AM, Pčolkins A, Kononova E, Bogdanova I, Polaka I, Stonans I, Kirsners A, Ager C, Mochalski P. Identification of Volatile Markers of Colorectal Cancer from Tumor Tissues Using Volatilomic Approach. Molecules 2023; 28:5990. [PMID: 37630241 PMCID: PMC10459111 DOI: 10.3390/molecules28165990] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 08/06/2023] [Accepted: 08/08/2023] [Indexed: 08/27/2023] Open
Abstract
The human body releases numerous volatile organic compounds (VOCs) through tissues and various body fluids, including breath. These compounds form a specific chemical profile that may be used to detect the colorectal cancer CRC-related changes in human metabolism and thereby diagnose this type of cancer. The main goal of this study was to investigate the volatile signatures formed by VOCs released from the CRC tissue. For this purpose, headspace solid-phase microextraction gas chromatography-mass spectrometry was applied. In total, 163 compounds were detected. Both cancerous and non-cancerous tissues emitted 138 common VOCs. Ten volatiles (2-butanone; dodecane; benzaldehyde; pyridine; octane; 2-pentanone; toluene; p-xylene; n-pentane; 2-methyl-2-propanol) occurred in at least 90% of both types of samples; 1-propanol in cancer tissue (86% in normal one), acetone in normal tissue (82% in cancer one). Four compounds (1-propanol, pyridine, isoprene, methyl thiolacetate) were found to have increased emissions from cancer tissue, whereas eleven showed reduced release from this type of tissue (2-butanone; 2-pentanone; 2-methyl-2-propanol; ethyl acetate; 3-methyl-1-butanol; d-limonene; tetradecane; dodecanal; tridecane; 2-ethyl-1-hexanol; cyclohexanone). The outcomes of this study provide evidence that the VOCs signature of the CRC tissue is altered by the CRC. The volatile constituents of this distinct signature can be emitted through exhalation and serve as potential biomarkers for identifying the presence of CRC. Reliable identification of the VOCs associated with CRC is essential to guide and tune the development of advanced sensor technologies that can effectively and sensitively detect and quantify these markers.
Collapse
Affiliation(s)
- Linda Mezmale
- Institute of Clinical and Preventive Medicine, Faculty of Medicine, University of Latvia, LV-1586 Riga, Latvia; (M.L.); (A.M.L.); (A.P.); (E.K.); (I.B.); (I.P.); (I.S.); (P.M.)
- Riga East University Hospital, LV-1038 Riga, Latvia
- Faculty of Residency, Riga Stradins University, LV-1007 Riga, Latvia
| | - Marcis Leja
- Institute of Clinical and Preventive Medicine, Faculty of Medicine, University of Latvia, LV-1586 Riga, Latvia; (M.L.); (A.M.L.); (A.P.); (E.K.); (I.B.); (I.P.); (I.S.); (P.M.)
- Riga East University Hospital, LV-1038 Riga, Latvia
- Digestive Diseases Centre GASTRO, LV-1079 Riga, Latvia
| | - Anna Marija Lescinska
- Institute of Clinical and Preventive Medicine, Faculty of Medicine, University of Latvia, LV-1586 Riga, Latvia; (M.L.); (A.M.L.); (A.P.); (E.K.); (I.B.); (I.P.); (I.S.); (P.M.)
- Riga East University Hospital, LV-1038 Riga, Latvia
| | - Andrejs Pčolkins
- Institute of Clinical and Preventive Medicine, Faculty of Medicine, University of Latvia, LV-1586 Riga, Latvia; (M.L.); (A.M.L.); (A.P.); (E.K.); (I.B.); (I.P.); (I.S.); (P.M.)
- Riga East University Hospital, LV-1038 Riga, Latvia
| | - Elina Kononova
- Institute of Clinical and Preventive Medicine, Faculty of Medicine, University of Latvia, LV-1586 Riga, Latvia; (M.L.); (A.M.L.); (A.P.); (E.K.); (I.B.); (I.P.); (I.S.); (P.M.)
- Faculty of Residency, Riga Stradins University, LV-1007 Riga, Latvia
| | - Inga Bogdanova
- Institute of Clinical and Preventive Medicine, Faculty of Medicine, University of Latvia, LV-1586 Riga, Latvia; (M.L.); (A.M.L.); (A.P.); (E.K.); (I.B.); (I.P.); (I.S.); (P.M.)
- Riga East University Hospital, LV-1038 Riga, Latvia
| | - Inese Polaka
- Institute of Clinical and Preventive Medicine, Faculty of Medicine, University of Latvia, LV-1586 Riga, Latvia; (M.L.); (A.M.L.); (A.P.); (E.K.); (I.B.); (I.P.); (I.S.); (P.M.)
| | - Ilmars Stonans
- Institute of Clinical and Preventive Medicine, Faculty of Medicine, University of Latvia, LV-1586 Riga, Latvia; (M.L.); (A.M.L.); (A.P.); (E.K.); (I.B.); (I.P.); (I.S.); (P.M.)
| | - Arnis Kirsners
- Institute of Clinical and Preventive Medicine, Faculty of Medicine, University of Latvia, LV-1586 Riga, Latvia; (M.L.); (A.M.L.); (A.P.); (E.K.); (I.B.); (I.P.); (I.S.); (P.M.)
| | - Clemens Ager
- Institute for Breath Research, University of Innsbruck, 6020 Dornbirn, Austria;
| | - Pawel Mochalski
- Institute of Clinical and Preventive Medicine, Faculty of Medicine, University of Latvia, LV-1586 Riga, Latvia; (M.L.); (A.M.L.); (A.P.); (E.K.); (I.B.); (I.P.); (I.S.); (P.M.)
- Institute for Breath Research, University of Innsbruck, 6020 Dornbirn, Austria;
- Institute of Chemistry, Jan Kochanowski University of Kielce, 25-369 Kielce, Poland
| |
Collapse
|
14
|
Vanstraelen S, Jones DR, Rocco G. Breathprinting analysis and biomimetic sensor technology to detect lung cancer. J Thorac Cardiovasc Surg 2023; 166:357-361.e1. [PMID: 36997463 DOI: 10.1016/j.jtcvs.2023.02.029] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 02/15/2023] [Accepted: 02/28/2023] [Indexed: 03/11/2023]
Affiliation(s)
- Stijn Vanstraelen
- Thoracic Service, Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, NY
| | - David R Jones
- Thoracic Service, Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, NY; Fiona and Stanley Druckenmiller Center for Lung Cancer Research, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Gaetano Rocco
- Thoracic Service, Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, NY; Fiona and Stanley Druckenmiller Center for Lung Cancer Research, Memorial Sloan Kettering Cancer Center, New York, NY.
| |
Collapse
|
15
|
Isinkaralar K, Meruyert K. Adsorption Behavior of Multi-Component BTEX on the Synthesized Green Adsorbents Derived from Abelmoschus esculentus L. Waste Residue. Appl Biochem Biotechnol 2023; 195:4864-4880. [PMID: 37093534 DOI: 10.1007/s12010-023-04556-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/18/2023] [Indexed: 04/25/2023]
Abstract
Benzene, toluene, ethylbenzene, and xylene (BTEX) removal is one of the most common difficulties in air pollution control. They are emitted from several processes, prejudicial to the environment and humans. BTEX leads to various environmental risks, and there is a significant need for a creating process for the complete removal of BTEX from air streams. This study's objective is the multi-component adsorption of BTEX pollutants from an air stream, by synthesizing activated carbons (ACs) under several operations. A lignocellulosic waste biomass, Abelmoschus esculentus L. (AE), was utilized as the precursor for synthesizing activated carbons (AE-ACs), and their surface chemical characteristics were investigated. Optimization processes were examined, and the change in the surface area of AE-ACs was investigated as change of some variables results like activation agent, impregnation ratio, temperature, and activation time. The maximum surface area of 968 m2/g and total pore volume of 0.51 cm3/g were attained at 1:2 impregnation ratio, activation time of 110 min, and activation temperature of 800 °C, under N2 atmosphere. A mixture of BTEX pollutants was employed to consider the effect of humidity (0.5, 1, 1.5, and 2 wt%) and initial concentrations (from 5 to 300 mg/m3), using a contact time of 120 min at the temperature of 25 °C. Under the studied conditions, the multi-component and single-component BTEX adsorption capacities by HCl-activated carbon, AE-ACH, were specifically achieved to 6.86-51.36 mg/g and 22-93.62 mg/g, respectively. Overall, Abelmoschus esculentus L. was exploited for the synthesis of AE-ACH which was successfully utilized for efficient BTEX capture from a polluted air stream.
Collapse
Affiliation(s)
- Kaan Isinkaralar
- Department of Environmental Engineering, Faculty of Engineering and Architecture, Kastamonu University, 37150, Kastamonu, Türkiye.
| | | |
Collapse
|
16
|
Savito L, Scarlata S, Bikov A, Carratù P, Carpagnano GE, Dragonieri S. Exhaled volatile organic compounds for diagnosis and monitoring of asthma. World J Clin Cases 2023; 11:4996-5013. [PMID: 37583852 PMCID: PMC10424019 DOI: 10.12998/wjcc.v11.i21.4996] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 06/08/2023] [Accepted: 07/06/2023] [Indexed: 07/26/2023] Open
Abstract
The asthmatic inflammatory process results in the generation of volatile organic compounds (VOCs), which are subsequently secreted by the airways. The study of these elements through gas chromatography-mass spectrometry (GC-MS), which can identify individual molecules with a discriminatory capacity of over 85%, and electronic-Nose (e-NOSE), which is able to perform a quick onboard pattern-recognition analysis of VOCs, has allowed new prospects for non-invasive analysis of the disease in an "omics" approach. In this review, we aim to collect and compare the progress made in VOCs analysis using the two methods and their instrumental characteristics. Studies have described the potential of GC-MS and e-NOSE in a multitude of relevant aspects of the disease in both children and adults, as well as differential diagnosis between asthma and other conditions such as wheezing, cystic fibrosis, COPD, allergic rhinitis and last but not least, the accuracy of these methods compared to other diagnostic tools such as lung function, FeNO and eosinophil count. Due to significant limitations of both methods, it is still necessary to improve and standardize techniques. Currently, e-NOSE appears to be the most promising aid in clinical practice, whereas GC-MS, as the gold standard for the structural analysis of molecules, remains an essential tool in terms of research for further studies on the pathophysiologic pathways of the asthmatic inflammatory process. In conclusion, the study of VOCs through GC-MS and e-NOSE appears to hold promise for the non-invasive diagnosis, assessment, and monitoring of asthma, as well as for further research studies on the disease.
Collapse
Affiliation(s)
- Luisa Savito
- Department of Internal Medicine, Unit of Respiratory Pathophysiology and Thoracic Endoscopy, Fondazione Policlinico Universitario Campus Bio Medico, Rome 00128, Italy
| | - Simone Scarlata
- Department of Internal Medicine, Unit of Respiratory Pathophysiology and Thoracic Endoscopy, Fondazione Policlinico Universitario Campus Bio Medico, Rome 00128, Italy
| | - Andras Bikov
- Wythenshawe Hospital, Manchester University NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester M13 9WL, United Kingdom
- Division of Infection, Immunity and Respiratory Medicine, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PT, United Kingdom
| | - Pierluigi Carratù
- Department of Internal Medicine "A.Murri", University of Bari "Aldo Moro", Bari 70124, Italy
| | | | - Silvano Dragonieri
- Department of Respiratory Diseases, University of Bari, Bari 70124, Italy
| |
Collapse
|
17
|
Xiang C, Yang H, Zhao Z, Deng F, Lv Y, Yang Y, Duan Y, Li W, Hu B. Volatolomics analysis of exhaled breath and gastric-endoluminal gas for distinguishing early upper gastrointestinal cancer from benign. J Breath Res 2023; 17:036004. [PMID: 37094569 DOI: 10.1088/1752-7163/accfb8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 04/24/2023] [Indexed: 04/26/2023]
Abstract
Exhaled breath and gastric-endoluminal gas (volatile products of diseased tissues) contain a large number of volatile organic compounds, which are valuable for early diagnosis of upper gastrointestinal (UGI) cancer. In this study, exhaled breath and gastric-endoluminal gas of patients with UGI cancer and benign disease were analyzed by gas chromatography-mass spectrometry (GC-MS) and ultraviolet photoionization time-of-flight mass spectrometry (UVP-TOFMS) to construct UGI cancer diagnostic models. Breath samples of 116 UGI cancer and 77 benign disease subjects and gastric-endoluminal gas samples of 114 UGI cancer and 76 benign disease subjects were collected. Machine learning (ML) algorithms were used to construct UGI cancer diagnostic models. Classification models based on exhaled breath for distinguishing UGI cancer from the benign group have area under the curve (AUC) of receiver operating characteristic curve values of 0.959 and 0.994 corresponding to GC-MS and UVP-TOFMS analysis, respectively. The AUC values of models based on gastric-endoluminal gas for UGI cancer and benign group classification are 0.935 and 0.929 corresponding to GC-MS and UVP-TOFMS analysis, respectively. This work indicates that volatolomics analysis of exhaled breath and gastric-endoluminal diseased tissues have great potential in early screening of UGI cancer. Moreover, gastric-endoluminal gas can be a means of gas biopsy to provide auxiliary information for the examination of tissue lesions during gastroscopy.
Collapse
Affiliation(s)
- Chengfang Xiang
- School of Chemistry, Sichuan University, Chengdu 610065, People's Republic of China
| | - Hang Yang
- Department of Gastroenterology, West China Hospital, Sichuan University, Chengdu 610064, People's Republic of China
| | - Zhongjun Zhao
- School of Mechanical Engineering, Sichuan University, Chengdu 610064, People's Republic of China
| | - Fulong Deng
- School of Mechanical Engineering, Sichuan University, Chengdu 610064, People's Republic of China
| | - Yantong Lv
- School of Chemical Engineering, Sichuan University, Chengdu 610064, People's Republic of China
| | - Yanting Yang
- Aliben Sci & Technol Co Ltd, Chengdu 611930, People's Republic of China
| | - Yixiang Duan
- School of Mechanical Engineering, Sichuan University, Chengdu 610064, People's Republic of China
- Aliben Sci & Technol Co Ltd, Chengdu 611930, People's Republic of China
| | - Wenwen Li
- West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu 610064, People's Republic of China
| | - Bing Hu
- Department of Gastroenterology, West China Hospital, Sichuan University, Chengdu 610064, People's Republic of China
| |
Collapse
|
18
|
Sharma A, Kumar R, Varadwaj P. Smelling the Disease: Diagnostic Potential of Breath Analysis. Mol Diagn Ther 2023; 27:321-347. [PMID: 36729362 PMCID: PMC9893210 DOI: 10.1007/s40291-023-00640-7] [Citation(s) in RCA: 35] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/11/2023] [Indexed: 02/03/2023]
Abstract
Breath analysis is a relatively recent field of research with much promise in scientific and clinical studies. Breath contains endogenously produced volatile organic components (VOCs) resulting from metabolites of ingested precursors, gut and air-passage bacteria, environmental contacts, etc. Numerous recent studies have suggested changes in breath composition during the course of many diseases, and breath analysis may lead to the diagnosis of such diseases. Therefore, it is important to identify the disease-specific variations in the concentration of breath to diagnose the diseases. In this review, we explore methods that are used to detect VOCs in laboratory settings, VOC constituents in exhaled air and other body fluids (e.g., sweat, saliva, skin, urine, blood, fecal matter, vaginal secretions, etc.), VOC identification in various diseases, and recently developed electronic (E)-nose-based sensors to detect VOCs. Identifying such VOCs and applying them as disease-specific biomarkers to obtain accurate, reproducible, and fast disease diagnosis could serve as an alternative to traditional invasive diagnosis methods. However, the success of VOC-based identification of diseases is limited to laboratory settings. Large-scale clinical data are warranted for establishing the robustness of disease diagnosis. Also, to identify specific VOCs associated with illness states, extensive clinical trials must be performed using both analytical instruments and electronic noses equipped with stable and precise sensors.
Collapse
Affiliation(s)
- Anju Sharma
- Systems Biology Lab, Indian Institute of Information Technology, Allahabad, Uttar Pradesh, India
| | - Rajnish Kumar
- Amity Institute of Biotechnology, Amity University Uttar Pradesh, Uttar Pradesh, Lucknow Campus, Lucknow, India
| | - Pritish Varadwaj
- Systems Biology Lab, Indian Institute of Information Technology, Allahabad, Uttar Pradesh, India.
| |
Collapse
|
19
|
Bhandari MP, Polaka I, Vangravs R, Mezmale L, Veliks V, Kirshners A, Mochalski P, Dias-Neto E, Leja M. Volatile Markers for Cancer in Exhaled Breath-Could They Be the Signature of the Gut Microbiota? Molecules 2023; 28:molecules28083488. [PMID: 37110724 PMCID: PMC10141340 DOI: 10.3390/molecules28083488] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 04/11/2023] [Accepted: 04/13/2023] [Indexed: 04/29/2023] Open
Abstract
It has been shown that the gut microbiota plays a central role in human health and disease. A wide range of volatile metabolites present in exhaled breath have been linked with gut microbiota and proposed as a non-invasive marker for monitoring pathological conditions. The aim of this study was to examine the possible correlation between volatile organic compounds (VOCs) in exhaled breath and the fecal microbiome by multivariate statistical analysis in gastric cancer patients (n = 16) and healthy controls (n = 33). Shotgun metagenomic sequencing was used to characterize the fecal microbiota. Breath-VOC profiles in the same participants were identified by an untargeted gas chromatography-mass spectrometry (GC-MS) technique. A multivariate statistical approach involving a canonical correlation analysis (CCA) and sparse principal component analysis identified the significant relationship between the breath VOCs and fecal microbiota. This relation was found to differ between gastric cancer patients and healthy controls. In 16 cancer cases, 14 distinct metabolites identified from the breath belonging to hydrocarbons, alcohols, aromatics, ketones, ethers, and organosulfur compounds were highly correlated with 33 fecal bacterial taxa (correlation of 0.891, p-value 0.045), whereas in 33 healthy controls, 7 volatile metabolites belonging to alcohols, aldehydes, esters, phenols, and benzamide derivatives correlated with 17 bacterial taxa (correlation of 0.871, p-value 0.0007). This study suggested that the correlation between fecal microbiota and breath VOCs was effective in identifying exhaled volatile metabolites and the functional effects of microbiome, thus helping to understand cancer-related changes and improving the survival and life expectancy in gastric cancer patients.
Collapse
Affiliation(s)
| | - Inese Polaka
- Institute of Clinical and Preventive Medicine, University of Latvia, LV-1586 Riga, Latvia
| | - Reinis Vangravs
- Institute of Clinical and Preventive Medicine, University of Latvia, LV-1586 Riga, Latvia
| | - Linda Mezmale
- Institute of Clinical and Preventive Medicine, University of Latvia, LV-1586 Riga, Latvia
- Riga East University Hospital, LV-1038 Riga, Latvia
- Faculty of Residency, Riga Stradins University, LV-1007 Riga, Latvia
| | - Viktors Veliks
- Institute of Clinical and Preventive Medicine, University of Latvia, LV-1586 Riga, Latvia
| | - Arnis Kirshners
- Institute of Clinical and Preventive Medicine, University of Latvia, LV-1586 Riga, Latvia
| | - Pawel Mochalski
- Institute of Chemistry, Jan Kochanowski University of Kielce, PL-25406 Kielce, Poland
- Institute for Breath Research, University of Innsbruck, A-6850 Dornbirn, Austria
| | - Emmanuel Dias-Neto
- Laboratory of Medical Genomics, A.C.Camargo Cancer Center, Sao Paulo 01508-010, Brazil
| | - Marcis Leja
- Institute of Clinical and Preventive Medicine, University of Latvia, LV-1586 Riga, Latvia
- Digestive Diseases Center GASTRO, LV-1079 Riga, Latvia
- Faculty of Medicine, University of Latvia, LV-1586 Riga, Latvia
| |
Collapse
|
20
|
Fenn D, Lilien TA, Hagens LA, Smit MR, Heijnen NF, Tuip-de Boer AM, Neerincx AH, Golebski K, Bergmans DC, Schnabel RM, Schultz MJ, Maitland-van der Zee AH, Brinkman P, Bos LD. Validation of volatile metabolites of pulmonary oxidative injury: a bench to bedside study. ERJ Open Res 2023; 9:00427-2022. [PMID: 36949963 PMCID: PMC10026006 DOI: 10.1183/23120541.00427-2022] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Accepted: 11/23/2022] [Indexed: 12/23/2022] Open
Abstract
Background Changes in exhaled volatile organic compounds (VOCs) can be used to discriminate between respiratory diseases, and increased concentrations of hydrocarbons are commonly linked to oxidative stress. However, the VOCs identified are inconsistent between studies, and translational studies are lacking. Methods In this bench to bedside study, we captured VOCs in the headspace of A549 epithelial cells after exposure to hydrogen peroxide (H2O2), to induce oxidative stress, using high-capacity polydimethylsiloxane sorbent fibres. Exposed and unexposed cells were compared using targeted and untargeted analysis. Breath samples of invasively ventilated intensive care unit patients (n=489) were collected on sorbent tubes and associated with the inspiratory oxygen fraction (F IO2 ) to reflect pulmonary oxidative stress. Headspace samples and breath samples were analysed using gas chromatography and mass spectrometry. Results In the cell, headspace octane concentration was decreased after oxidative stress (p=0.0013), while the other VOCs were not affected. 2-ethyl-1-hexanol showed an increased concentration in the headspace of cells undergoing oxidative stress in untargeted analysis (p=0.00014). None of the VOCs that were linked to oxidative stress showed a significant correlation with F IO2 (Rs range: -0.015 to -0.065) or discriminated between patients with F IO2 ≥0.6 or below (area under the curve range: 0.48 to 0.55). Conclusion Despite a comprehensive translational approach, validation of known and novel volatile biomarkers of oxidative stress was not possible in patients at risk of pulmonary oxidative injury. The inconsistencies observed highlight the difficulties faced in VOC biomarker validation, and that caution is warranted in the interpretation of the pathophysiological origin of discovered exhaled breath biomarkers.
Collapse
Affiliation(s)
- Dominic Fenn
- Amsterdam UMC location University of Amsterdam, Department of Pulmonary Medicine, Amsterdam, Netherlands
- Amsterdam UMC location University of Amsterdam, Laboratory of Experimental Intensive Care and Anaesthesiology, Amsterdam, Netherlands
- Corresponding author: Dominic Fenn ()
| | - Thijs A. Lilien
- Amsterdam UMC location University of Amsterdam, Laboratory of Experimental Intensive Care and Anaesthesiology, Amsterdam, Netherlands
- Amsterdam UMC location University of Amsterdam, Department of Paediatric Intensive Care, Amsterdam, Netherlands
| | - Laura A. Hagens
- Amsterdam UMC location University of Amsterdam, Department of Intensive Care, Amsterdam, Netherlands
| | - Marry R. Smit
- Amsterdam UMC location University of Amsterdam, Department of Intensive Care, Amsterdam, Netherlands
| | - Nanon F.L. Heijnen
- Department of Intensive Care, Maastricht University Medical Center+, Maastricht, The Netherlands
- School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, Maastricht, Netherlands
| | - Anita M. Tuip-de Boer
- Amsterdam UMC location University of Amsterdam, Laboratory of Experimental Intensive Care and Anaesthesiology, Amsterdam, Netherlands
| | - Anne H. Neerincx
- Amsterdam UMC location University of Amsterdam, Department of Pulmonary Medicine, Amsterdam, Netherlands
| | - Korneliusz Golebski
- Amsterdam UMC location University of Amsterdam, Department of Pulmonary Medicine, Amsterdam, Netherlands
- Amsterdam UMC location University of Amsterdam, Department of Experimental Immunology, Amsterdam, Netherlands
| | - Dennis C.J.J. Bergmans
- Department of Intensive Care, Maastricht University Medical Center+, Maastricht, The Netherlands
- School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, Maastricht, Netherlands
| | - Ronny M. Schnabel
- Department of Intensive Care, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - Marcus J. Schultz
- Amsterdam UMC location University of Amsterdam, Department of Intensive Care, Amsterdam, Netherlands
| | | | - Paul Brinkman
- Amsterdam UMC location University of Amsterdam, Department of Pulmonary Medicine, Amsterdam, Netherlands
| | - Lieuwe D.J. Bos
- Amsterdam UMC location University of Amsterdam, Department of Pulmonary Medicine, Amsterdam, Netherlands
- Amsterdam UMC location University of Amsterdam, Laboratory of Experimental Intensive Care and Anaesthesiology, Amsterdam, Netherlands
- Amsterdam UMC location University of Amsterdam, Department of Intensive Care, Amsterdam, Netherlands
| |
Collapse
|
21
|
Analysis of Volatile Organic Compounds in Exhaled Breath Following a COMEX-30 Treatment Table. Metabolites 2023; 13:metabo13030316. [PMID: 36984755 PMCID: PMC10056109 DOI: 10.3390/metabo13030316] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 02/17/2023] [Accepted: 02/20/2023] [Indexed: 02/24/2023] Open
Abstract
The COMEX-30 hyperbaric treatment table is used to manage decompression sickness in divers but may result in pulmonary oxygen toxicity (POT). Volatile organic compounds (VOCs) in exhaled breath are early markers of hyperoxic stress that may be linked to POT. The present study assessed whether VOCs following COMEX-30 treatment are early markers of hyperoxic stress and/or POT in ten healthy, nonsmoking volunteers. Because more oxygen is inhaled during COMEX-30 treatment than with other treatment tables, this study hypothesized that VOCs exhaled following COMEX-30 treatment are indicators of POT. Breath samples were collected before and 0.5, 2, and 4 h after COMEX-30 treatment. All subjects were followed-up for signs of POT or other symptoms. Nine compounds were identified, with four (nonanal, decanal, ethyl acetate, and tridecane) increasing 33–500% in intensity from before to after COMEX-30 treatment. Seven subjects reported pulmonary symptoms, five reported out-of-proportion tiredness and transient ear fullness, and four had signs of mild dehydration. All VOCs identified following COMEX-30 treatment have been associated with inflammatory responses or pulmonary diseases, such as asthma or lung cancer. Because most subjects reported transient pulmonary symptoms reflecting early-stage POT, the identified VOCs are likely markers of POT, not just hyperbaric hyperoxic exposure.
Collapse
|
22
|
Potential Role of Oxidative Stress in the Production of Volatile Organic Compounds in Obesity. Antioxidants (Basel) 2023; 12:antiox12010129. [PMID: 36670991 PMCID: PMC9854577 DOI: 10.3390/antiox12010129] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Revised: 12/30/2022] [Accepted: 01/03/2023] [Indexed: 01/06/2023] Open
Abstract
Obesity is associated with numerous health issues such as sleep disorders, asthma, hepatic dysfunction, cancer, renal dysfunction, diabetes, cardiovascular complications, and infertility. Previous research has shown that the distribution of excess body fat, rather than excess body weight, determines obesity-related risk factors. It is widely accepted that abdominal fat is a serious risk factor for illnesses associated with obesity and the accumulation of visceral fat promotes the release of pro-oxidants, pro-inflammatory, and reactive oxygen species (ROS). The metabolic process in the human body produces several volatile organic compounds (VOCs) via urine, saliva, breath, blood, skin secretions, milk, and feces. Several studies have shown that VOCs are released by the interaction of ROS with underlying cellular components leading to increased protein oxidation, lipid peroxidation, or DNA damage. These VOCs released via oxidative stress in obese individuals may serves as a biomarker for obesity-related metabolic alterations and disease. In this review, we focus on the relationship between oxidative stress and VOCs in obesity.
Collapse
|
23
|
MATSUMORI SEI, HASHIMOTO TAKASHI, NASU MOTOMI, KAGA NAOKO, TAKA HIKARI, FUJIMURA TSUTOMU, UENO TAKASHI, MIURA YOSHIKI, KAJIYAMA YOSHIAKI. Development of a Non-invasive Diagnostic Method for Esophageal Squamous Cell Carcinoma by Gas Chromatographic Analysis of Exhaled Breath. JUNTENDO IJI ZASSHI = JUNTENDO MEDICAL JOURNAL 2022; 68:499-504. [PMID: 39081580 PMCID: PMC11284284 DOI: 10.14789/jmj.jmj22-0023-oa] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Accepted: 07/08/2022] [Indexed: 08/02/2024]
Abstract
Objectives Since esophageal carcinoma progresses asymptomatically, for many patients the disease is already advanced at the time of diagnosis. The main methods that are currently used to diagnose esophageal carcinoma are upper gastrointestinal radiographic contrast examinations and upper gastrointestinal endoscopy, but early discovery of this disease remains difficult. There is a need to develop a diagnostic method using biomarkers that is non-invasive while both highly sensitive and specific. Materials and Methods Exhaled breath was collected from 17 patients with esophageal squamous cell carcinoma (ESCC), as well as 9 control subjects without history of any cancer. For each fasting subject, 1L of exhaled breath was collected in a gas sampling bag. Volatile organic compounds (VOCs) were then extracted from each sample using Solid phase micro-extraction (SPME) fibers and analyzed by gas chromatography-mass spectrometry (GC-MS). Results Levels of acetonitrile, acetic acid, acetone, and 2-butanone in exhaled breath were significantly higher in the patient group than in the control group (p = 0.0037, 0.0024, 0.0024 and 0.0037, respectively). ROC curves were drawn for these 4 VOCs, and the results for the area-under-the-curve (AUC) indicated that ESCC patients can be identified with a high probability of 0.93. Conclusion We found distinctive VOCs in exhaled breath of ESCC patients. These VOCs have a potential as new clinical biomarkers for ESCC. The measurement of VOCs in exhaled breath may be a useful, non-invasive method for diagnosis of ESCC.
Collapse
Affiliation(s)
| | - TAKASHI HASHIMOTO
- Corresponding author: Takashi Hashimoto, Department of Esophageal and Gastroenterological Surgery, Juntendo University Graduate School of Medicine, 2-1-1 Hongo Bunkyo-ku, Tokyo 113-8421, Japan, TEL: +81-3-3813-3111 FAX: +81-3-5802-1951 E-mail:
| | | | | | | | | | | | | | | |
Collapse
|
24
|
Keogh RJ, Riches JC. The Use of Breath Analysis in the Management of Lung Cancer: Is It Ready for Primetime? Curr Oncol 2022; 29:7355-7378. [PMID: 36290855 PMCID: PMC9600994 DOI: 10.3390/curroncol29100578] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/22/2022] [Accepted: 09/28/2022] [Indexed: 11/07/2022] Open
Abstract
Breath analysis is a promising non-invasive method for the detection and management of lung cancer. Exhaled breath contains a complex mixture of volatile and non-volatile organic compounds that are produced as end-products of metabolism. Several studies have explored the patterns of these compounds and have postulated that a unique breath signature is emitted in the setting of lung cancer. Most studies have evaluated the use of gas chromatography and mass spectrometry to identify these unique breath signatures. With recent advances in the field of analytical chemistry and machine learning gaseous chemical sensing and identification devices have also been created to detect patterns of odorant molecules such as volatile organic compounds. These devices offer hope for a point-of-care test in the future. Several prospective studies have also explored the presence of specific genomic aberrations in the exhaled breath of patients with lung cancer as an alternative method for molecular analysis. Despite its potential, the use of breath analysis has largely been limited to translational research due to methodological issues, the lack of standardization or validation and the paucity of large multi-center studies. It is clear however that it offers a potentially non-invasive alternative to investigations such as tumor biopsy and blood sampling.
Collapse
|
25
|
Volatilomic Signatures of AGS and SNU-1 Gastric Cancer Cell Lines. Molecules 2022; 27:molecules27134012. [PMID: 35807254 PMCID: PMC9268292 DOI: 10.3390/molecules27134012] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 06/18/2022] [Accepted: 06/18/2022] [Indexed: 02/06/2023] Open
Abstract
In vitro studies can help reveal the biochemical pathways underlying the origin of volatile indicators of numerous diseases. The key objective of this study is to identify the potential biomarkers of gastric cancer. For this purpose, the volatilomic signatures of two human gastric cancer cell lines, AGS (human gastric adenocarcinoma) and SNU-1 (human gastric carcinoma), and one normal gastric mucosa cell line (GES-1) were investigated. More specifically, gas chromatography mass spectrometry has been applied to pinpoint changes in cell metabolism triggered by cancer. In total, ten volatiles were found to be metabolized, and thirty-five were produced by cells under study. The volatiles consumed were mainly six aldehydes and two heterocyclics, whereas the volatiles released embraced twelve ketones, eight alcohols, six hydrocarbons, three esters, three ethers, and three aromatic compounds. The SNU-1 cell line was found to have significantly altered metabolism in comparison to normal GES-1 cells. This was manifested by the decreased production of alcohols and ketones and the upregulated emission of esters. The AGS cells exhibited the increased production of methyl ketones containing an odd number of carbons, namely 2-tridecanone, 2-pentadecanone, and 2-heptadecanone. This study provides evidence that the cancer state modifies the volatilome of human cells.
Collapse
|
26
|
Jakšić M, Mihajlović A, Vujić D, Giannoukos S, Brkić B. Membrane inlet mass spectrometry method for food intake impact assessment on specific volatile organic compounds in exhaled breath. Anal Bioanal Chem 2022; 414:6077-6091. [PMID: 35727330 PMCID: PMC9314300 DOI: 10.1007/s00216-022-04168-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2022] [Revised: 05/24/2022] [Accepted: 06/07/2022] [Indexed: 11/30/2022]
Abstract
This research work describes the development of a novel bioanalytical method for the assessment of food impact on selected exhaled breath volatile organic compounds (VOCs) using a fast and portable screening VOC prototype sensor based on membrane inlet mass spectrometry (MIMS). Method and sensor prototype functionality was verified by obtaining good response times, linearity in the examined concentration ranges, and sensitivity and repeatability for several breath VOCs—acetone, ethanol, n-pentane, and isoprene. A new VOC sensor prototype was also proven to be sensitive enough for selected breath VOC quantification with limits of detection at low part per billion (ppb) levels—5 ppb for n-pentane, 10 ppb for acetone and ethanol, and 25 ppb for isoprene. Food impact assessment was accomplished by tracking the levels of acetone, ethanol, n-pentane, and isoprene in exhaled breath samples collected from 50 healthy participants before the meal and 60 min and 120 min after the meal. For acetone, isoprene, and n-pentane, a larger impact was noticed 120 min after the meal, while for ethanol, it was after 60 min. Obtained VOC levels were in the expected concentration ranges. Mean values at all time points were ~ 500–900 ppb for acetone and ~ 400–600 ppb for ethanol. Most of the results for n-pentane were below 5 ppb, but the mean value for those which were detected was ~ 30 ppb. Along with samples, data about participants’ lifestyle were collected via a short questionnaire, which were compared against obtained VOC levels in order to reveal some significant correlations between habits of participants and their breath VOC levels.
Collapse
Affiliation(s)
- Milena Jakšić
- BioSense Institute, University of Novi Sad, Dr Zorana Djindjića 1, 21000, Novi Sad, Serbia.
| | - Andrea Mihajlović
- BioSense Institute, University of Novi Sad, Dr Zorana Djindjića 1, 21000, Novi Sad, Serbia
| | - Djordje Vujić
- BioSense Institute, University of Novi Sad, Dr Zorana Djindjića 1, 21000, Novi Sad, Serbia
| | - Stamatios Giannoukos
- Department of Chemistry and Applied Biosciences, ETH Zurich, HCI D 317, Vladimir-Prelog-Weg 3, CH-8093, Zurich, Switzerland
| | - Boris Brkić
- BioSense Institute, University of Novi Sad, Dr Zorana Djindjića 1, 21000, Novi Sad, Serbia.
| |
Collapse
|
27
|
de Jong FJM, Brinkman P, Wingelaar TT, van Ooij PJAM, van Hulst RA. Volatile Organic Compounds Frequently Identified after Hyperbaric Hyperoxic Exposure: The VAPOR Library. Metabolites 2022; 12:470. [PMID: 35629974 PMCID: PMC9142890 DOI: 10.3390/metabo12050470] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 05/06/2022] [Accepted: 05/13/2022] [Indexed: 01/31/2023] Open
Abstract
Diving or hyperbaric oxygen therapy with increased partial pressures of oxygen (pO2) can have adverse effects such as central nervous system oxygen toxicity or pulmonary oxygen toxicity (POT). Prevention of POT has been a topic of interest for several decades. One of the most promising techniques to determine early signs of POT is the analysis of volatile organic compounds (VOCs) in exhaled breath. We reanalyzed the data of five studies to compose a library of potential exhaled markers for the early detection of POT. GC-MS data from five hyperbaric hyperoxic studies were collected. Wilcoxon signed-rank tests were used to compare baseline- and postexposure measurements; all ion fragments that significantly varied were compared by similarity using the National Institute of Standards and Technology (NIST) library. All identified molecules were cross-referenced with open-source databases and other scientific publications on VOCs to exclude compounds that occurred as a result of contamination, and to identify the compounds most likely to occur due to hyperbaric hyperoxic exposure. After identification and removal of contaminants, 29 compounds were included in the library. This library of hyperbaric hyperoxic-related VOCs can help to advance the development of an early noninvasive marker of POT. It enables validation by others who use more targeted MS-related techniques, instead of full-scale GC-MS, for their exhaled VOC research.
Collapse
Affiliation(s)
- Feiko J. M. de Jong
- Royal Netherlands Navy Diving and Submarine Medical Centre, 1780 CA Den Helder, The Netherlands; (T.T.W.); (P.-J.A.M.v.O.)
- Department of Anesthesiology, Amsterdam UMC, Location AMC, 1100 DD Amsterdam, The Netherlands;
| | - Paul Brinkman
- Department of Respiratory Medicine, Amsterdam UMC, Location AMC, University of Amsterdam, 1100 DD Amsterdam, The Netherlands;
| | - Thijs T. Wingelaar
- Royal Netherlands Navy Diving and Submarine Medical Centre, 1780 CA Den Helder, The Netherlands; (T.T.W.); (P.-J.A.M.v.O.)
- Department of Anesthesiology, Amsterdam UMC, Location AMC, 1100 DD Amsterdam, The Netherlands;
| | - Pieter-Jan A. M. van Ooij
- Royal Netherlands Navy Diving and Submarine Medical Centre, 1780 CA Den Helder, The Netherlands; (T.T.W.); (P.-J.A.M.v.O.)
- Department of Respiratory Medicine, Amsterdam UMC, Location AMC, University of Amsterdam, 1100 DD Amsterdam, The Netherlands;
| | - Rob A. van Hulst
- Department of Anesthesiology, Amsterdam UMC, Location AMC, 1100 DD Amsterdam, The Netherlands;
| |
Collapse
|
28
|
Exhaled Breath Volatile Organic Compound Analysis for the Detection of Lung Cancer- A Systematic Review. JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING 2022. [DOI: 10.4028/p-dab04j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A rapid and effective diagnostic method is essential for lung cancer since it shows symptoms only at its advanced stage. Research is being carried out in the area of exhaled breath analysis for the diagnosis of various pulmonary diseases including lung cancer. In this method exhaled breath volatile organic compounds (VOC) are analyzed with various techniques such as gas chromatography-mass spectrometry, ion mobility spectrometry, and electronic noses. The VOC analysis is suitable for lung cancer detection since it is non-invasive, fast, and also a low-cost method. In addition, this technique can detect primary stage nodules. This paper presents a systematic review of the various method employed by researchers in the breath analysis field. The articles were selected through various search engines like EMBASE, Google Scholar, Pubmed, and Google. In the initial screening process, 214 research papers were selected using various inclusion and exclusion criteria and finally, 55 articles were selected for the review. The results of the reviewed studies show that detection of lung cancer can be effectively done using the VOC analysis of exhaled breath. The results also show that this method can be used for detecting the different stages and histology of lung cancer. The exhaled breath VOC analysis technique will be popular in the future, bypassing the existing imaging techniques. This systematic review conveys the recent research opportunities, obstacles, difficulties, motivations, and suggestions associated with the breath analysis method for lung cancer detection.
Collapse
|
29
|
Yu Q, Chen J, Fu W, Muhammad KG, Li Y, Liu W, Xu L, Dong H, Wang D, Liu J, Lu Y, Chen X. Smartphone-Based Platforms for Clinical Detections in Lung-Cancer-Related Exhaled Breath Biomarkers: A Review. BIOSENSORS 2022; 12:bios12040223. [PMID: 35448283 PMCID: PMC9028493 DOI: 10.3390/bios12040223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 04/01/2022] [Accepted: 04/05/2022] [Indexed: 12/24/2022]
Abstract
Lung cancer has been studied for decades because of its high morbidity and high mortality. Traditional methods involving bronchoscopy and needle biopsy are invasive and expensive, which makes patients suffer more risks and costs. Various noninvasive lung cancer markers, such as medical imaging indices, volatile organic compounds (VOCs), and exhaled breath condensates (EBCs), have been discovered for application in screening, diagnosis, and prognosis. However, the detection of markers still relies on bulky and professional instruments, which are limited to training personnel or laboratories. This seriously hinders population screening for early diagnosis of lung cancer. Advanced smartphones integrated with powerful applications can provide easy operation and real-time monitoring for healthcare, which demonstrates tremendous application scenarios in the biomedical analysis region from medical institutions or laboratories to personalized medicine. In this review, we propose an overview of lung-cancer-related noninvasive markers from exhaled breath, focusing on the novel development of smartphone-based platforms for the detection of these biomarkers. Lastly, we discuss the current limitations and potential solutions.
Collapse
Affiliation(s)
- Qiwen Yu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China; (Q.Y.); (W.F.); (K.G.M.); (Y.L.); (W.L.); (L.X.); (J.L.)
| | - Jing Chen
- School of Medical Technology and Information Engineering, Zhejiang Chinese Medical University, Hangzhou 310051, China;
| | - Wei Fu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China; (Q.Y.); (W.F.); (K.G.M.); (Y.L.); (W.L.); (L.X.); (J.L.)
| | - Kanhar Ghulam Muhammad
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China; (Q.Y.); (W.F.); (K.G.M.); (Y.L.); (W.L.); (L.X.); (J.L.)
| | - Yi Li
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China; (Q.Y.); (W.F.); (K.G.M.); (Y.L.); (W.L.); (L.X.); (J.L.)
| | - Wenxin Liu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China; (Q.Y.); (W.F.); (K.G.M.); (Y.L.); (W.L.); (L.X.); (J.L.)
| | - Linxin Xu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China; (Q.Y.); (W.F.); (K.G.M.); (Y.L.); (W.L.); (L.X.); (J.L.)
| | - Hao Dong
- Research Center for Sensing Materials and Devices, Zhejiang Lab, Hangzhou 311100, China; (H.D.); (D.W.)
| | - Di Wang
- Research Center for Sensing Materials and Devices, Zhejiang Lab, Hangzhou 311100, China; (H.D.); (D.W.)
| | - Jun Liu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China; (Q.Y.); (W.F.); (K.G.M.); (Y.L.); (W.L.); (L.X.); (J.L.)
| | - Yanli Lu
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China; (Q.Y.); (W.F.); (K.G.M.); (Y.L.); (W.L.); (L.X.); (J.L.)
- Correspondence: (Y.L.); (X.C.)
| | - Xing Chen
- Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Education Ministry, Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China; (Q.Y.); (W.F.); (K.G.M.); (Y.L.); (W.L.); (L.X.); (J.L.)
- Correspondence: (Y.L.); (X.C.)
| |
Collapse
|
30
|
Stefanuto PH, Romano R, Rees CA, Nasir M, Thakuria L, Simon A, Reed AK, Marczin N, Hill JE. Volatile organic compound profiling to explore primary graft dysfunction after lung transplantation. Sci Rep 2022; 12:2053. [PMID: 35136125 PMCID: PMC8827074 DOI: 10.1038/s41598-022-05994-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Accepted: 11/29/2021] [Indexed: 01/07/2023] Open
Abstract
Primary graft dysfunction (PGD) is a major determinant of morbidity and mortality following lung transplantation. Delineating basic mechanisms and molecular signatures of PGD remain a fundamental challenge. This pilot study examines if the pulmonary volatile organic compound (VOC) spectrum relate to PGD and postoperative outcomes. The VOC profiles of 58 bronchoalveolar lavage fluid (BALF) and blind bronchial aspirate samples from 35 transplant patients were extracted using solid-phase-microextraction and analyzed with comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry. The support vector machine algorithm was used to identify VOCs that could differentiate patients with severe from lower grade PGD. Using 20 statistically significant VOCs from the sample headspace collected immediately after transplantation (< 6 h), severe PGD was differentiable from low PGD with an AUROC of 0.90 and an accuracy of 0.83 on test set samples. The model was somewhat effective for later time points with an AUROC of 0.80. Three major chemical classes in the model were dominated by alkylated hydrocarbons, linear hydrocarbons, and aldehydes in severe PGD samples. These VOCs may have important clinical and mechanistic implications, therefore large-scale study and potential translation to breath analysis is recommended.
Collapse
Affiliation(s)
- Pierre-Hugues Stefanuto
- Thayer School of Engineering, Dartmouth College, Hanover, NH, USA.,Organic and Biological Analytical Chemistry Group, Liège University, Liège, Belgium
| | - Rosalba Romano
- Department of Surgery and Cancer, Section of Anaesthetics, Imperial College of London, London, UK.,Harefield Hospital, Royal Brompton and Harefield NHS Foundation Trust, Harefield, UK
| | | | - Mavra Nasir
- Geisel School of Medicine, Dartmouth College, Hanover, NH, USA
| | - Louit Thakuria
- Harefield Hospital, Royal Brompton and Harefield NHS Foundation Trust, Harefield, UK
| | - Andre Simon
- Harefield Hospital, Royal Brompton and Harefield NHS Foundation Trust, Harefield, UK
| | - Anna K Reed
- Harefield Hospital, Royal Brompton and Harefield NHS Foundation Trust, Harefield, UK
| | - Nandor Marczin
- Department of Surgery and Cancer, Section of Anaesthetics, Imperial College of London, London, UK.,Harefield Hospital, Royal Brompton and Harefield NHS Foundation Trust, Harefield, UK.,Department of Anesthesia and Intensive Care, Semmelweis University, Budapest, Hungary
| | - Jane E Hill
- Thayer School of Engineering, Dartmouth College, Hanover, NH, USA. .,Geisel School of Medicine, Dartmouth College, Hanover, NH, USA. .,Department of Chemical and Biological Engineering, University of British Columbia, Vancouver, Canada.
| |
Collapse
|
31
|
Issitt T, Wiggins L, Veysey M, Sweeney S, Brackenbury W, Redeker K. Volatile compounds in human breath: critical review and meta-analysis. J Breath Res 2022; 16. [PMID: 35120340 DOI: 10.1088/1752-7163/ac5230] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Accepted: 02/04/2022] [Indexed: 11/12/2022]
Abstract
Volatile compounds contained in human breath reflect the inner workings of the body. A large number of studies have been published that link individual components of breath to disease, but diagnostic applications remain limited, in part due to inconsistent and conflicting identification of breath biomarkers. New approaches are therefore required to identify effective biomarker targets. Here, volatile organic compounds have been identified in the literature from four metabolically and physiologically distinct diseases and grouped into chemical functional groups (e.g. - methylated hydrocarbons or aldehydes; based on known metabolic and enzymatic pathways) to support biomarker discovery and provide new insight on existing data. Using this functional grouping approach, principal component analysis doubled explanatory capacity from 19.1% to 38% relative to single individual compound approaches. Random forest and linear discriminant analysis reveal 93% classification accuracy for cancer. This review and meta-analysis provides insight for future research design by identifying volatile functional groups associated with disease. By incorporating our understanding of the complexities of the human body, along with accounting for variability in methodological and analytical approaches, this work demonstrates that a suite of targeted, functional volatile biomarkers, rather than individual biomarker compounds, will improve accuracy and success in diagnostic research and application.
Collapse
Affiliation(s)
- Theo Issitt
- Biology, University of York, University of York, York, York, YO10 5DD, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Laura Wiggins
- Biology, University of York, University of York, York, York, YO10 5DD, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Martin Veysey
- The University of Newcastle, School of Medicine & Public Health, Callaghan, New South Wales, 2308, AUSTRALIA
| | - Sean Sweeney
- Biology, University of York, University of York, York, York, YO10 5DD, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - William Brackenbury
- Biology, University of York, University of York, York, York, YO10 5DD, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Kelly Redeker
- Biology, University of York, Biology Dept. University of York, York, York, North Yorkshire, YO10 5DD, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| |
Collapse
|
32
|
Plantier L, Smolinska A, Fijten R, Flamant M, Dallinga J, Mercadier JJ, Pachen D, d'Ortho MP, van Schooten FJ, Crestani B, Boots AW. The use of exhaled air analysis in discriminating interstitial lung diseases: a pilot study. Respir Res 2022; 23:12. [PMID: 35057817 PMCID: PMC8772159 DOI: 10.1186/s12931-021-01923-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 12/29/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Fibrotic Interstitial lung diseases (ILD) are a heterogeneous group of chronic lung diseases characterized by diverse degrees of lung inflammation and remodeling. They include idiopathic ILD such as idiopathic pulmonary fibrosis (IPF), and ILD secondary to chronic inflammatory diseases such as connective tissue disease (CTD). Precise differential diagnosis of ILD is critical since anti-inflammatory and immunosuppressive drugs, which are beneficial in inflammatory ILD, are detrimental in IPF. However, differential diagnosis of ILD is still difficult and often requires an invasive lung biopsy. The primary aim of this study is to identify volatile organic compounds (VOCs) patterns in exhaled air to non-invasively discriminate IPF and CTD-ILD. As secondary aim, the association between the IPF and CTD-ILD discriminating VOC patterns and functional impairment is investigated. METHODS Fifty-three IPF patients, 53 CTD-ILD patients and 51 controls donated exhaled air, which was analyzed for its VOC content using gas chromatograph- time of flight- mass spectrometry. RESULTS By applying multivariate analysis, a discriminative profile of 34 VOCs was observed to discriminate between IPF patients and healthy controls whereas 11 VOCs were able to distinguish between CTD-ILD patients and healthy controls. The separation between IPF and CTD-ILD could be made using 16 discriminating VOCs, that also displayed a significant correlation with total lung capacity and the 6 min' walk distance. CONCLUSIONS This study reports for the first time that specific VOC profiles can be found to differentiate IPF and CTD-ILD from both healthy controls and each other. Moreover, an ILD-specific VOC profile was strongly correlated with functional parameters. Future research applying larger cohorts of patients suffering from a larger variety of ILDs should confirm the potential use of breathomics to facilitate fast, non-invasive and proper differential diagnosis of specific ILDs in the future as first step towards personalized medicine for these complex diseases.
Collapse
Affiliation(s)
- L Plantier
- Department of Pulmonology and Lung Function Testing, CHRU, Tours, France
- Université de Tours, Tours, France
- Centre d'Etude des Pathologies Respiratoires, INSERM UMR1100, Tours, France
| | - A Smolinska
- Department of Pharmacology and Toxicology, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands
| | - R Fijten
- Department of Pharmacology and Toxicology, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands
- Department of Radiation Oncology (Maastro) GROW School for Oncology and Developmental Biology, Maastricht University Medical Centre, 6229 ET, Maastricht, The Netherlands
| | - M Flamant
- Service de Physiologie - Explorations Fonctionnelle, Assistance Publique-Hôpitaux de Paris, Hôpital Bichat, Paris, France
| | - J Dallinga
- Department of Pharmacology and Toxicology, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands
| | - J J Mercadier
- Service de Physiologie - Explorations Fonctionnelle, Assistance Publique-Hôpitaux de Paris, Hôpital Bichat, Paris, France
| | - D Pachen
- Department of Pharmacology and Toxicology, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands
| | - M P d'Ortho
- Service de Physiologie - Explorations Fonctionnelle, Assistance Publique-Hôpitaux de Paris, Hôpital Bichat, Paris, France
- Université de Paris, INSERM UMR 1141, NeuroDiderot, France
| | - F J van Schooten
- Department of Pharmacology and Toxicology, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands
| | - B Crestani
- Service de Pneumologie A, DHU FIRE, Assistance Publique-Hôpitaux de Paris, Hôpital Bichat, Paris, France
- Université Paris Diderot, PRES Sorbonne Paris Cité, Paris, France
- INSERM UMR1152, Labex Inflamex, Paris, France
| | - A W Boots
- Department of Pharmacology and Toxicology, NUTRIM School of Nutrition and Translational Research in Metabolism, Maastricht University, Maastricht, The Netherlands.
| |
Collapse
|
33
|
Volatile organic compounds as a potential screening tool for neoplasm of the digestive system: a meta-analysis. Sci Rep 2021; 11:23716. [PMID: 34887450 PMCID: PMC8660806 DOI: 10.1038/s41598-021-02906-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Accepted: 11/24/2021] [Indexed: 02/02/2023] Open
Abstract
This meta-analysis was aimed to estimate the diagnostic performance of volatile organic compounds (VOCs) as a potential novel tool to screen for the neoplasm of the digestive system. An integrated literature search was performed by two independent investigators to identify all relevant studies investigating VOCs in diagnosing neoplasm of the digestive system from inception to 7th December 2020. STATA and Revman software were used for data analysis. The methodological quality of each study was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. A bivariate mixed model was used and meta-regression and subgroup analysis were performed to identify possible sources of heterogeneity. A total of 36 studies comprised of 1712 cases of neoplasm and 3215 controls were included in our meta-analysis. Bivariate analysis showed a pooled sensitivity of 0.87 (95% confidence interval (CI) 0.83–0.90), specificity of 0.86 (95% CI 0.82–0.89), a positive likelihood ratio of 6.18 (95% CI 4.68–8.17), and a negative likelihood ratio of 0.15 (95% CI 0.12–0.20). The diagnostic odds ratio and the area under the summary ROC curve for diagnosing neoplasm of the digestive system were 40.61 (95% CI 24.77–66.57) and 0.93 (95% CI 0.90–0.95), respectively. Our analyses revealed that VOCs analysis could be considered as a potential novel tool to screen for malignant diseases of the digestive system.
Collapse
|
34
|
Phillips M, Grun F, Schmitt P. Breath biomarkers of total body irradiation in non-human primates. J Breath Res 2021; 16. [PMID: 34781275 DOI: 10.1088/1752-7163/ac39aa] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 11/15/2021] [Indexed: 11/11/2022]
Abstract
BACKGROUND Radiation exposure causes oxidative stress, eliciting production of metabolites that are exhaled in the breath as volatile organic compounds (VOCs). We evaluated breath VOCs as potential biomarkers for use in radiation biodosimetry. METHODS Five anesthetized non-human primates receive total body irradiation (TBI) of three daily fractions of 120 cGy per day for three days, resulting in a cumulative dose of 10.8 Gy. Breath samples were collected prior to irradiation and after each radiation fraction, and analyzed with gas chromatography mass spectrometry. RESULTS TBI elicited a prompt and statistically significant increase in the abundance of several hundred VOCs in the breath, including some that were increased more than five-fold, with100% sensitivity and 100% specificity for radiation exposure. The most significant breath VOC biomarkers of radiation mainly comprised straight-chain n-alkanes (e.g. hexane), as well as methylated alkanes (e.g. 3-methyl-pentane) and alkane derivatives (e.g. 2-butyl-1-octanol), consistent with metabolic products of oxidative stress. An unidentified breath VOC biomarker increased more than ten-fold following TBI, and rose linearly with the total cumulative dose of radiation (R2=0.92). CONCLUSIONS TBI of non-human primates elicited increased production of breath VOCs consistent with increased oxidative stress. These findings provide a rational basis for further evaluation of breath VOC biomarkers in human radiation biodosimetry.
Collapse
Affiliation(s)
- Michael Phillips
- Menssana Research INC, Suite 517, 211 Warren Street, Newark, NJ 07103, USA, Newark, New Jersey, 07103, UNITED STATES
| | - Felix Grun
- Mass Spectrometry Facility, University of California Irvine, Irvine, CA 92697-2025, Irvine, California, 92697, UNITED STATES
| | - Peter Schmitt
- Schmitt & Associates, , 211 Warren St, Newark, NJ 07103, Newark, New Jersey, 07103, UNITED STATES
| |
Collapse
|
35
|
Mey JT, Rath MC, McLaughlin K, Galang M, Lynch K, DiMattio J, Nason H, Yang S, Melillo CA, Grove DE, Tonelli AR, Heresi GA, Kirwan JP, Dweik RA. The breath print represents a novel biomarker of malnutrition in pulmonary arterial hypertension: A proof of concept study. JPEN J Parenter Enteral Nutr 2021; 45:1645-1652. [PMID: 34633675 PMCID: PMC9244406 DOI: 10.1002/jpen.2277] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
BACKGROUND The breath print is a quantitative measurement of molecules in exhaled breath and represents a new frontier for biomarker identification. It is unknown whether this state-of-the-art, noninvasive method can detect malnutrition. We hypothesize that individuals with malnutrition will present with a distinguishable breath print. METHODS We conducted a retrospective chart review on patients with previously analyzed breath samples to identify malnutrition. Breath was analyzed by selected-ion flow-tube mass spectrometry. Registered dietitians conducted a retrospective chart review to collect malnutrition diagnoses and nutrition status indicators. Patients were categorized into one of four groups: pulmonary arterial hypertension (PAH), PAH with malnutrition (PAH-Mal), control, and control with malnutrition (Control-Mal), based on the malnutrition diagnosis present in the patient's chart. Principle component analysis was conducted to characterize the breath print. A logistic regression model with forward selection was used to detect the best breath predictor combination of malnutrition. RESULTS A total of 74 patients met inclusion criteria (PAH: 52; PAH-Mal: 10; control: 10; Control-Mal: 2). Levels of 1-octene (PAH-Mal, 5.1 ± 1.2; PAH, 12.5 ± 11.2; P = 0.005) and ammonia (PAH-Mal, 14.6 ± 15.8; PAH, 56.2 ± 64.2; P = 0.013) were reduced in PAH-Mal compared with PAH. The combination of 1-octene (P = 0.010) and 3-methylhexane (P = 0.045) distinguished malnutrition in PAH (receiver operating characteristic area under the curve: 0.8549). CONCLUSIONS This proof of concept study provides the first evidence that the breath print is altered in malnutrition. Larger prospective studies are needed to validate these results and establish whether breath analysis may be a useful tool to screen for malnutrition in the clinical setting.
Collapse
Affiliation(s)
- Jacob T. Mey
- Pennington Biomedical Research Center, Baton Rouge, Louisiana, USA
| | - Mary C. Rath
- Center for Human Nutrition, Cleveland Clinic, Cleveland, Ohio, USA
| | | | - Marianne Galang
- Center for Human Nutrition, Cleveland Clinic, Cleveland, Ohio, USA
| | - Kathryn Lynch
- Center for Human Nutrition, Cleveland Clinic, Cleveland, Ohio, USA
| | - Jaime DiMattio
- Center for Human Nutrition, Cleveland Clinic, Cleveland, Ohio, USA
| | - Hillary Nason
- Center for Human Nutrition, Cleveland Clinic, Cleveland, Ohio, USA,Nutrition Department, Case Western Reserve University, Cleveland, Ohio, USA
| | - Shengping Yang
- Pennington Biomedical Research Center, Baton Rouge, Louisiana, USA
| | - Celia A. Melillo
- Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - David E. Grove
- Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | | | | | - John P. Kirwan
- Pennington Biomedical Research Center, Baton Rouge, Louisiana, USA
| | - Raed A. Dweik
- Respiratory Institute, Cleveland Clinic, Cleveland, Ohio, USA
| |
Collapse
|
36
|
Zhang J, Tian Y, Luo Z, Qian C, Li W, Duan Y. Breath volatile organic compound analysis: an emerging method for gastric cancer detection. J Breath Res 2021; 15. [PMID: 34610588 DOI: 10.1088/1752-7163/ac2cde] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2021] [Accepted: 10/05/2021] [Indexed: 12/14/2022]
Abstract
Gastric cancer is a common malignancy, being the fifth most frequently diagnosed cancer and the fourth leading cause of cancer-related deaths worldwide. Diagnosis of gastric cancer at the early stage is critical to effectively improve the survival rate. However, a substantial proportion of patients with gastric cancer in the early stages lack specific symptoms or are asymptomatic. Moreover, the imaging techniques currently used for gastric cancer screening, such as computed tomography and barium examination, are usually radioactive and have low sensitivity and specificity. Even though endoscopy has high accuracy for gastric cancer screening, its application is limited by the invasiveness of the technique. Breath analysis is an economic, effective, easy to perform, non-invasive detection method, and has no undesirable side effects on subjects. Extensive worldwide research has been conducted on breath volatile organic compounds (VOCs), which reveals its prospect as a potential method for gastric cancer detection. Many interesting results have been obtained and innovative methods have been introduced in this subject; hence, an extensive review would be beneficial. By providing a comprehensive list of breath VOCs identified by gastric cancer would promote further research in this field. This review summarizes the commonly used technologies for exhaled breath analysis, focusing on the application of analytical instruments in the detection of breath VOCs in gastric cancers, and the alterations in the profile of breath biomarkers in gastric cancer patients are discussed as well.
Collapse
Affiliation(s)
- Jing Zhang
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, People's Republic of China
| | - Yonghui Tian
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, People's Republic of China
| | - Zewei Luo
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, People's Republic of China
| | - Cheng Qian
- Shaanxi Key Laboratory of Earth Surface System and Environmental Carrying Capacity, College of Urban and Environmental Sciences, Northwest University, Xi'an 710127, People's Republic of China
| | - Wenwen Li
- West China School of Public Health and West China Fourth Hospital, Sichuan University, Chengdu 610041, People's Republic of China
| | - Yixiang Duan
- Research Center of Analytical Instrumentation, Key Laboratory of Synthetic and Natural Functional Molecule Chemistry of Ministry of Education, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, People's Republic of China
| |
Collapse
|
37
|
Hagens LA, Heijnen NFL, Smit MR, Verschueren ARM, Nijsen TME, Geven I, Schultz MJ, Bergmans DCJJ, Schnabel RM, Bos LDJ. Diagnosis of acute respiratory distress syndrome (DARTS) by bedside exhaled breath octane measurements in invasively ventilated patients: protocol of a multicentre observational cohort study. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:1262. [PMID: 34532399 PMCID: PMC8421964 DOI: 10.21037/atm-21-1384] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/22/2021] [Accepted: 05/28/2021] [Indexed: 11/08/2022]
Abstract
Background Acute respiratory distress syndrome (ARDS) is currently diagnosed by the Berlin Definition. Diagnosis is subjective and often late. Untargeted metabolomics analysis of exhaled breath with gas chromatography and mass spectrometry (GC-MS) showed that the breath concentration of octane has a high diagnostic accuracy for ARDS. To facilitate rapid bedside measurement of this biomarker, a point-of-care (POC) breath test was developed. A prototype already showed good reproducibility and repeatability for the detection of octane. In this study we aim to measure octane in exhaled breath of invasively ventilated intensive care unit (ICU) patients and validate the diagnostic accuracy of the breath test for the early diagnosis of ARDS. Methods This is a multicentre observational cohort study in patients admitted to the ICU receiving invasive ventilation for at least 24 hours. At least 500 patients in two academic hospitals in The Netherlands will be included. ARDS patients will be compared to patients without ARDS. ARDS diagnosis will be based on the Berlin Definition. Two diagnostic assessments will be performed during the first 72 hours of invasive ventilation, including breath sampling, arterial blood gas analysis and lung ultrasound (LUS). In patients fulfilling the criteria for ARDS, three additional breath samples will be taken to assess resolution. The primary endpoint is the diagnostic accuracy for ARDS, defined by the area under the receiver operating characteristics curve (AUROCC) of octane concentration in exhaled breath. Secondary endpoints are the association between exhaled breath octane and ARDS adjusted for confounders, and the added diagnostic accuracy of the breath test on top of the Lung Injury Prediction Score (LIPS). Discussion This is the first study that validates a metabolic biomarker of ARDS in an adequate sample size. The major novelty is the use of a POC breath test that has been specifically developed for the purpose of diagnosing ARDS. Strengths are; assessment in the early phase, in patients at risk for ARDS, longitudinal sampling and an expert panel to reliably diagnose ARDS. This study will provide a decisive answer on the question if exhaled breath metabolomics can be used to diagnose ARDS. Trial registration The trial is registered at trialregister.nl (ID: NL8226) with the tag “DARTS”.
Collapse
Affiliation(s)
- Laura A Hagens
- Department of Intensive Care, Amsterdam UMC, Location AMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Nanon F L Heijnen
- Department of Intensive Care, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - Marry R Smit
- Department of Intensive Care, Amsterdam UMC, Location AMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Alwin R M Verschueren
- Sleep & Respiratory Solutions, Philips Research, High Tech Campus, Eindhoven, The Netherlands
| | - Tamara M E Nijsen
- Sleep & Respiratory Solutions, Philips Research, High Tech Campus, Eindhoven, The Netherlands
| | - Inge Geven
- Sleep & Respiratory Solutions, Philips Research, High Tech Campus, Eindhoven, The Netherlands
| | - Marcus J Schultz
- Department of Intensive Care, Amsterdam UMC, Location AMC, University of Amsterdam, Amsterdam, The Netherlands.,Mahidol-Oxford Tropical Medicine Research Unit (MORU), Mahidol University, Bangkok, Thailand.,Nuffield Department of Medicine, University of Oxford, Oxford, UK
| | - Dennis C J J Bergmans
- Department of Intensive Care, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - Ronny M Schnabel
- Department of Intensive Care, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - Lieuwe D J Bos
- Department of Intensive Care, Amsterdam UMC, Location AMC, University of Amsterdam, Amsterdam, The Netherlands.,Department of Respiratory Medicine, Amsterdam UMC, Location AMC, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
38
|
Kim C, Raja IS, Lee JM, Lee JH, Kang MS, Lee SH, Oh JW, Han DW. Recent Trends in Exhaled Breath Diagnosis Using an Artificial Olfactory System. BIOSENSORS 2021; 11:337. [PMID: 34562928 PMCID: PMC8467588 DOI: 10.3390/bios11090337] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 09/06/2021] [Accepted: 09/10/2021] [Indexed: 12/26/2022]
Abstract
Artificial olfactory systems are needed in various fields that require real-time monitoring, such as healthcare. This review introduces cases of detection of specific volatile organic compounds (VOCs) in a patient's exhaled breath and discusses trends in disease diagnosis technology development using artificial olfactory technology that analyzes exhaled human breath. We briefly introduce algorithms that classify patterns of odors (VOC profiles) and describe artificial olfactory systems based on nanosensors. On the basis of recently published research results, we describe the development trend of artificial olfactory systems based on the pattern-recognition gas sensor array technology and the prospects of application of this technology to disease diagnostic devices. Medical technologies that enable early monitoring of health conditions and early diagnosis of diseases are crucial in modern healthcare. By regularly monitoring health status, diseases can be prevented or treated at an early stage, thus increasing the human survival rate and reducing the overall treatment costs. This review introduces several promising technical fields with the aim of developing technologies that can monitor health conditions and diagnose diseases early by analyzing exhaled human breath in real time.
Collapse
Affiliation(s)
- Chuntae Kim
- BIO-IT Foundry Technology Institute, Pusan National University, Busan 46241, Korea
| | | | - Jong-Min Lee
- School of Nano Convergence Technology, Hallym University, Chuncheon 24252, Korea
| | | | - Moon Sung Kang
- Department of Cogno-Mechatronics Engineering, Pusan National University, Busan 46241, Korea
| | - Seok Hyun Lee
- Department of Cogno-Mechatronics Engineering, Pusan National University, Busan 46241, Korea
| | - Jin-Woo Oh
- BIO-IT Foundry Technology Institute, Pusan National University, Busan 46241, Korea
- Department of Nanoenergy Engineering, Pusan National University, Busan 46241, Korea
| | - Dong-Wook Han
- BIO-IT Foundry Technology Institute, Pusan National University, Busan 46241, Korea
- Department of Cogno-Mechatronics Engineering, Pusan National University, Busan 46241, Korea
| |
Collapse
|
39
|
Pham YL, Beauchamp J. Breath Biomarkers in Diagnostic Applications. Molecules 2021; 26:molecules26185514. [PMID: 34576985 PMCID: PMC8468811 DOI: 10.3390/molecules26185514] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 09/07/2021] [Accepted: 09/08/2021] [Indexed: 02/06/2023] Open
Abstract
The detection of chemical compounds in exhaled human breath presents an opportunity to determine physiological state, diagnose disease or assess environmental exposure. Recent advancements in metabolomics research have led to improved capabilities to explore human metabolic profiles in breath. Despite some notable challenges in sampling and analysis, exhaled breath represents a desirable medium for metabolomics applications, foremost due to its non-invasive, convenient and practically limitless availability. Several breath-based tests that target either endogenous or exogenous gas-phase compounds are currently established and are in practical and/or clinical use. This review outlines the concept of breath analysis in the context of these unique tests and their applications. The respective breath biomarkers targeted in each test are discussed in relation to their physiological production in the human body and the development and implementation of the associated tests. The paper concludes with a brief insight into prospective tests and an outlook of the future direction of breath research.
Collapse
Affiliation(s)
- Y Lan Pham
- Department of Sensory Analytics and Technologies, Fraunhofer Institute for Process Engineering and Packaging IVV, Giggenhauser Straße 35, 85354 Freising, Germany;
- Department of Chemistry and Pharmacy, Chair of Aroma and Smell Research, Friedrich-Alexander-Universität Erlangen-Nürnberg, Henkestraße 9, 91054 Erlangen, Germany
| | - Jonathan Beauchamp
- Department of Sensory Analytics and Technologies, Fraunhofer Institute for Process Engineering and Packaging IVV, Giggenhauser Straße 35, 85354 Freising, Germany;
- Correspondence:
| |
Collapse
|
40
|
Vishinkin R, Busool R, Mansour E, Fish F, Esmail A, Kumar P, Gharaa A, Cancilla JC, Torrecilla JS, Skenders G, Leja M, Dheda K, Singh S, Haick H. Profiles of Volatile Biomarkers Detect Tuberculosis from Skin. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2021; 8:e2100235. [PMID: 34075714 PMCID: PMC8336503 DOI: 10.1002/advs.202100235] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Revised: 03/19/2021] [Indexed: 02/05/2023]
Abstract
Tuberculosis (TB) is an infectious disease that threatens >10 million people annually. Despite advances in TB diagnostics, patients continue to receive an insufficient diagnosis as TB symptoms are not specific. Many existing biodiagnostic tests are slow, have low clinical performance, and can be unsuitable for resource-limited settings. According to the World Health Organization (WHO), a rapid, sputum-free, and cost-effective triage test for real-time detection of TB is urgently needed. This article reports on a new diagnostic pathway enabling a noninvasive, fast, and highly accurate way of detecting TB. The approach relies on TB-specific volatile organic compounds (VOCs) that are detected and quantified from the skin headspace. A specifically designed nanomaterial-based sensors array translates these findings into a point-of-care diagnosis by discriminating between active pulmonary TB patients and controls with sensitivity above 90%. This fulfills the WHO's triage test requirements and poses the potential to become a TB triage test.
Collapse
Affiliation(s)
- Rotem Vishinkin
- Department of Chemical Engineering and Russell Berrie Nanotechnology InstituteTechnion‐Israel Institute of TechnologyHaifa3200003Israel
| | - Rami Busool
- Department of Chemical Engineering and Russell Berrie Nanotechnology InstituteTechnion‐Israel Institute of TechnologyHaifa3200003Israel
| | - Elias Mansour
- Department of Chemical Engineering and Russell Berrie Nanotechnology InstituteTechnion‐Israel Institute of TechnologyHaifa3200003Israel
| | - Falk Fish
- Department of Chemical Engineering and Russell Berrie Nanotechnology InstituteTechnion‐Israel Institute of TechnologyHaifa3200003Israel
| | - Ali Esmail
- Centre for Lung Infection and ImmunityDivision of PulmonologyDepartment of Medicine and UCT Lung Institute & South African MRC/UCT Centre for the Study of Antimicrobial ResistanceUniversity of Cape TownCape Town 7925South Africa
| | - Parveen Kumar
- All India Institute of Medical SciencesNew Delhi110029India
| | - Alaa Gharaa
- Department of Chemical Engineering and Russell Berrie Nanotechnology InstituteTechnion‐Israel Institute of TechnologyHaifa3200003Israel
| | | | - Jose S. Torrecilla
- Department of Chemical and Materials EngineeringComplutense University of MadridMadrid28040Spain
| | - Girts Skenders
- Institute of Clinical and Preventive MedicineUniversity of Latvia and Riga east University HospitalRigaLV1079Latvia
| | - Marcis Leja
- Institute of Clinical and Preventive MedicineUniversity of Latvia and Riga east University HospitalRigaLV1079Latvia
| | - Keertan Dheda
- Centre for Lung Infection and ImmunityDivision of PulmonologyDepartment of Medicine and UCT Lung Institute & South African MRC/UCT Centre for the Study of Antimicrobial ResistanceUniversity of Cape TownCape Town 7925South Africa
- Faculty of Infectious and Tropical DiseasesDepartment of Infection BiologyLondon School of Hygiene and Tropical MedicineLondonWC1E 7HTUK
| | - Sarman Singh
- All India Institute of Medical SciencesNew Delhi110029India
| | - Hossam Haick
- Department of Chemical Engineering and Russell Berrie Nanotechnology InstituteTechnion‐Israel Institute of TechnologyHaifa3200003Israel
| |
Collapse
|
41
|
Jaeschke C, Padilla M, Glöckler J, Polaka I, Leja M, Veliks V, Mitrovics J, Leja M, Mizaikoff B. Modular Breath Analyzer (MBA): Introduction of a Breath Analyzer Platform Based on an Innovative and Unique, Modular eNose Concept for Breath Diagnostics and Utilization of Calibration Transfer Methods in Breath Analysis Studies. Molecules 2021; 26:3776. [PMID: 34205805 PMCID: PMC8235513 DOI: 10.3390/molecules26123776] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 06/11/2021] [Accepted: 06/14/2021] [Indexed: 11/17/2022] Open
Abstract
Exhaled breath analysis for early disease detection may provide a convenient method for painless and non-invasive diagnosis. In this work, a novel, compact and easy-to-use breath analyzer platform with a modular sensing chamber and direct breath sampling unit is presented. The developed analyzer system comprises a compact, low volume, temperature-controlled sensing chamber in three modules that can host any type of resistive gas sensor arrays. Furthermore, in this study three modular breath analyzers are explicitly tested for reproducibility in a real-life breath analysis experiment with several calibration transfer (CT) techniques using transfer samples from the experiment. The experiment consists of classifying breath samples from 15 subjects before and after eating a specific meal using three instruments. We investigate the possibility to transfer calibration models across instruments using transfer samples from the experiment under study, since representative samples of human breath at some conditions are difficult to simulate in a laboratory. For example, exhaled breath from subjects suffering from a disease for which the biomarkers are mostly unknown. Results show that many transfer samples of all the classes under study (in our case meal/no meal) are needed, although some CT methods present reasonably good results with only one class.
Collapse
Affiliation(s)
- Carsten Jaeschke
- Institute of Analytical and Bioanalytical Chemistry, University of Ulm, Albert-Einstein-Allee 11, 89081 Ulm, Germany; (C.J.); (J.G.)
| | - Marta Padilla
- JLM Innovation GmbH, Vor dem Kreuzberg 17, 72070 Tuebingen, Germany; (M.P.); (J.M.)
| | - Johannes Glöckler
- Institute of Analytical and Bioanalytical Chemistry, University of Ulm, Albert-Einstein-Allee 11, 89081 Ulm, Germany; (C.J.); (J.G.)
| | - Inese Polaka
- Institute of Clinical and Preventive Medicine, University of Latvia, LV-1079 Riga, Latvia; (I.P.); (M.L.); (V.V.); (M.L.)
| | - Martins Leja
- Institute of Clinical and Preventive Medicine, University of Latvia, LV-1079 Riga, Latvia; (I.P.); (M.L.); (V.V.); (M.L.)
| | - Viktors Veliks
- Institute of Clinical and Preventive Medicine, University of Latvia, LV-1079 Riga, Latvia; (I.P.); (M.L.); (V.V.); (M.L.)
| | - Jan Mitrovics
- JLM Innovation GmbH, Vor dem Kreuzberg 17, 72070 Tuebingen, Germany; (M.P.); (J.M.)
| | - Marcis Leja
- Institute of Clinical and Preventive Medicine, University of Latvia, LV-1079 Riga, Latvia; (I.P.); (M.L.); (V.V.); (M.L.)
| | - Boris Mizaikoff
- Institute of Analytical and Bioanalytical Chemistry, University of Ulm, Albert-Einstein-Allee 11, 89081 Ulm, Germany; (C.J.); (J.G.)
| |
Collapse
|
42
|
Ghosh C, Leon A, Koshy S, Aloum O, Al-Jabawi Y, Ismail N, Weiss ZF, Koo S. Breath-Based Diagnosis of Infectious Diseases: A Review of the Current Landscape. Clin Lab Med 2021; 41:185-202. [PMID: 34020759 DOI: 10.1016/j.cll.2021.03.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Various analytical methods can be applied to concentrate, separate, and examine trace volatile organic metabolites in the breath, with the potential for noninvasive, rapid, real-time identification of various disease processes, including an array of microbial infections. Although biomarker discovery and validation in microbial infections can be technically challenging, it is an approach that has shown great promise, especially for infections that are particularly difficult to identify with standard culture and molecular amplification-based approaches. This article discusses the current state of breath analysis for the diagnosis of infectious diseases.
Collapse
Affiliation(s)
- Chiranjit Ghosh
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| | - Armando Leon
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| | - Seena Koshy
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| | - Obadah Aloum
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| | - Yazan Al-Jabawi
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| | - Nour Ismail
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA
| | - Zoe Freeman Weiss
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA; Division of Infectious Diseases, Massachusetts General Hospital, Boston, MA 02114, USA
| | - Sophia Koo
- Division of Infectious Diseases, Brigham and Women's Hospital, 181 Longwood Avenue, MCP642, Boston, MA 02115, USA; Harvard Medical School, 25 Shattuck Street, Boston, MA 02115, USA; Dana-Farber Cancer Institute, 450 Brookline Avenue, Boston, MA 02215, USA.
| |
Collapse
|
43
|
Monedeiro F, Monedeiro-Milanowski M, Ratiu IA, Brożek B, Ligor T, Buszewski B. Needle Trap Device-GC-MS for Characterization of Lung Diseases Based on Breath VOC Profiles. Molecules 2021; 26:molecules26061789. [PMID: 33810121 PMCID: PMC8004837 DOI: 10.3390/molecules26061789] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 03/16/2021] [Accepted: 03/19/2021] [Indexed: 01/08/2023] Open
Abstract
Volatile organic compounds (VOCs) have been assessed in breath samples as possible indicators of diseases. The present study aimed to quantify 29 VOCs (previously reported as potential biomarkers of lung diseases) in breath samples collected from controls and individuals with lung cancer, chronic obstructive pulmonary disease and asthma. Besides that, global VOC profiles were investigated. A needle trap device (NTD) was used as pre-concentration technique, associated to gas chromatography-mass spectrometry (GC-MS) analysis. Univariate and multivariate approaches were applied to assess VOC distributions according to the studied diseases. Limits of quantitation ranged from 0.003 to 6.21 ppbv and calculated relative standard deviations did not exceed 10%. At least 15 of the quantified targets presented themselves as discriminating features. A random forest (RF) method was performed in order to classify enrolled conditions according to VOCs' latent patterns, considering VOCs responses in global profiles. The developed model was based on 12 discriminating features and provided overall balanced accuracy of 85.7%. Ultimately, multinomial logistic regression (MLR) analysis was conducted using the concentration of the nine most discriminative targets (2-propanol, 3-methylpentane, (E)-ocimene, limonene, m-cymene, benzonitrile, undecane, terpineol, phenol) as input and provided an average overall accuracy of 95.5% for multiclass prediction.
Collapse
Affiliation(s)
- Fernanda Monedeiro
- Interdisciplinary Centre of Modern Technologies, Nicolaus Copernicus University in Toruń, 4 Wileńska St., 87-100 Toruń, Poland; (F.M.); (M.M.-M.); (I.-A.R.); (B.B.)
| | - Maciej Monedeiro-Milanowski
- Interdisciplinary Centre of Modern Technologies, Nicolaus Copernicus University in Toruń, 4 Wileńska St., 87-100 Toruń, Poland; (F.M.); (M.M.-M.); (I.-A.R.); (B.B.)
| | - Ileana-Andreea Ratiu
- Interdisciplinary Centre of Modern Technologies, Nicolaus Copernicus University in Toruń, 4 Wileńska St., 87-100 Toruń, Poland; (F.M.); (M.M.-M.); (I.-A.R.); (B.B.)
- “Raluca Ripan” Institute for Research in Chemistry, Babeş-Bolyai University, 30 Fântânele St., RO-400294 Cluj-Napoca, Romania
- Department of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarina St., 87-100 Toruń, Poland
| | - Beata Brożek
- Department of Lung Diseases, Provincial Polyclinic Hospital in Toruń, 4 Krasińskiego St., 87-100 Toruń, Poland;
| | - Tomasz Ligor
- Interdisciplinary Centre of Modern Technologies, Nicolaus Copernicus University in Toruń, 4 Wileńska St., 87-100 Toruń, Poland; (F.M.); (M.M.-M.); (I.-A.R.); (B.B.)
- Department of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarina St., 87-100 Toruń, Poland
- Correspondence: ; Tel.: +48-(56)-665-60-58
| | - Bogusław Buszewski
- Interdisciplinary Centre of Modern Technologies, Nicolaus Copernicus University in Toruń, 4 Wileńska St., 87-100 Toruń, Poland; (F.M.); (M.M.-M.); (I.-A.R.); (B.B.)
- Department of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarina St., 87-100 Toruń, Poland
| |
Collapse
|
44
|
Xiang L, Wu S, Hua Q, Bao C, Liu H. Volatile Organic Compounds in Human Exhaled Breath to Diagnose Gastrointestinal Cancer: A Meta-Analysis. Front Oncol 2021; 11:606915. [PMID: 33747921 PMCID: PMC7970758 DOI: 10.3389/fonc.2021.606915] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Accepted: 01/21/2021] [Indexed: 12/11/2022] Open
Abstract
Introduction Human exhaled volatile organic compounds (VOCs) are being extensively studied for the purposes of noninvasive cancer diagnoses. This article was primarily to assess the feasibility of utilizing exhaled VOCs analysis for gastrointestinal cancer (GIC) diagnosis. Methods PRISMA-based system searches were conducted for related studies of exhaled VOCs in GIC diagnosis based on predetermined criteria. Relevant articles on colorectal cancer and gastroesophageal cancer were summarized, and meta analysis was performed on articles providing sensitivity and specificity data. Results From 2,227 articles, 14 were found to meet inclusion criteria, six of which were on colorectal cancer (CRC) and eight on Gastroesophageal cancer(GEC). Five articles could provide specific data of sensitivity and specificity in GEC, which were used for meta-analysis. The pooled sensitivity, specificity, diagnostic odds ratio (DOR), and area under the curve (AUC) were calculated based on the combination of these data, and were 85.0% [95% confidence interval (CI): 79.0%-90.0%], 89.0% (95%CI: 86.0%-91.0%), 41.30 (21.56-79.10), and 0.93, respectively. Conclusion VOCs can distinguish gastrointestinal cancers from other gastrointestinal diseases, opening up a new avenue for the diagnosis and identification of gastrointestinal cancers, and the analysis of VOCs in exhaled breath has potential clinical application in screening. VOCs are promising tumor biomarkers for GIC diagnosis. Furthermore, limitations like the heterogeneity of diagnostic VOCs between studies should be minded.
Collapse
Affiliation(s)
- Lijuan Xiang
- Department of Tumor Biotherapy (5th Ward of the Department of Oncology), Anhui Provincial Cancer Hospital, West District of The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China.,Department of Oncology, The First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Sihan Wu
- Department of Tumor Biotherapy (5th Ward of the Department of Oncology), Anhui Provincial Cancer Hospital, West District of The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China.,Department of Oncology, Affiliated Provincial Hospital of Anhui Medical University, Hefei, China
| | - Qingling Hua
- Department of Oncology, Yijishan Hospital, Wannan Medical College, Wuhu, China
| | - Chuyang Bao
- Department of Oncology, The First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Hu Liu
- Department of Tumor Biotherapy (5th Ward of the Department of Oncology), Anhui Provincial Cancer Hospital, West District of The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China
| |
Collapse
|
45
|
Wen Q, Boshier P, Myridakis A, Belluomo I, Hanna GB. Urinary Volatile Organic Compound Analysis for the Diagnosis of Cancer: A Systematic Literature Review and Quality Assessment. Metabolites 2020; 11:17. [PMID: 33383923 PMCID: PMC7824454 DOI: 10.3390/metabo11010017] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 12/14/2020] [Accepted: 12/24/2020] [Indexed: 12/11/2022] Open
Abstract
The analysis of urinary volatile organic compounds (VOCs) is a promising field of research with the potential to discover new biomarkers for cancer early detection. This systematic review aims to summarise the published literature concerning cancer-associated urinary VOCs. A systematic online literature search was conducted to identify studies reporting urinary VOC biomarkers of cancers in accordance with the recommendations of the Cochrane Library and Meta-analysis of Observational Studies in Epidemiology (MOOSE) guidelines. Thirteen studies comprising 1266 participants in total were included in the review. Studies reported urinary VOC profiles of five cancer subtypes: prostate cancer, gastrointestinal cancer, leukaemia/lymphoma, lung cancer, and bladder cancer. Forty-eight urinary VOCs belonging to eleven chemical classes were identified with high diagnostic performance. VOC profiles were distinctive for each cancer type with limited cross-over. The metabolic analysis suggested distinctive phenotypes for prostate and gastrointestinal cancers. The heterogenicity of study design, methodological and reporting quality may have contributed to inconsistencies between studies. Urinary VOC analysis has shown promising performance for non-invasive diagnosis of cancer. However, limitations in study design have resulted in inconsistencies between studies. These limitations are summarised and discussed in order to support future studies.
Collapse
Affiliation(s)
| | | | | | | | - George B. Hanna
- Department of Surgery and Cancer, Imperial College London, St Mary’s Hospital, London W2 1NY, UK; (Q.W.); (P.B.); (A.M.); (I.B.)
| |
Collapse
|
46
|
Yi N, Shen M, Erdely D, Cheng H. Stretchable gas sensors for detecting biomarkers from humans and exposed environments. Trends Analyt Chem 2020; 133:116085. [PMID: 33244191 PMCID: PMC7685242 DOI: 10.1016/j.trac.2020.116085] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The recent advent of stretchable gas sensors demonstrates their capabilities to detect not only gaseous biomarkers from the human body but also toxic gas species from the exposed environment. To ensure accurate gas detection without device breakdown from the mechanical deformations, the stretchable gas sensors often rely on the direct integration of gas-sensitive nanomaterials on the stretchable substrate or fibrous network, as well as being configured into stretchable structures. The nanomaterials in the forms of nanoparticles, nanowires, or thin-films with nanometer thickness are explored for a variety of sensing materials. The commonly used stretchable structures in the stretchable gas sensors include wrinkled structures from a pre-strain strategy, island-bridge layouts or serpentine interconnects, strain isolation approaches, and their combinations. This review aims to summarize the recent advancement in novel nanomaterials, sensor design innovations, and new fabrication approaches of stretchable gas sensors.
Collapse
Affiliation(s)
- Ning Yi
- Department of Materials Science and Engineering, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Mingzhou Shen
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Daniel Erdely
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA
| | - Huanyu Cheng
- Department of Materials Science and Engineering, The Pennsylvania State University, University Park, PA, 16802, USA
- Department of Engineering Science and Mechanics, The Pennsylvania State University, University Park, PA, 16802, USA
| |
Collapse
|
47
|
Fielding D, Hartel G, Pass D, Davis M, Brown M, Dent A, Agnew J, Dickie G, Ware RS, Hodge R. Volatile organic compound breath testing detects in-situ squamous cell carcinoma of bronchial and laryngeal regions and shows distinct profiles of each tumour. J Breath Res 2020; 14:046013. [PMID: 33021204 DOI: 10.1088/1752-7163/abb18a] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Volatile organic compound (VOC) breath testing of lung and head and neck squamous cell carcinoma (SCC) has been widely studied, however little is known regarding VOC profiles of in-situ SCC. A prospective study of VOC in patients with histologically proven SCC, either in-situ or advanced, and controls. Breath samples were analysed using the E-nose Cyranose ®320 and by gas chromatography/mass spectroscopy. Predictive models were developed using bootstrap forest using all 32 sensors. Data from 55 participants was analysed: 42 SCC cases comprising 20 bronchial (10 in-situ, 10 advanced) and 22 laryngeal (12 in-situ, 10 advanced), and 13 controls. There were 32 (76%) male SCC cases with mean age 63.6 (SD = 9.5) compared with 11 (85%) male controls with mean age 61.9 (SD = 10.1). Predictive models for in situ cases had good sensitivity and specificity compared to controls (overall, 95% and 69%; laryngeal, 100% and 85%; bronchial, 77% and 80%). When distinguishing in-situ and advanced tumours, sensitivity and specificity 82% and 75% respectively. For different tumour types (bronchial versus advanced laryngeal) sensitivity and specificity were 100% and 80% respectively. VOCs isolated from in-situ cancers included some previously demonstrated in advanced cancers and some novel VOCs. In-situ bronchial and laryngeal cancer can be detected by VOC analysis. Distinction from normal controls and between the two tumour types could allow screening in high risk groups for these curable lesions.
Collapse
Affiliation(s)
- David Fielding
- Department of Thoracic Medicine, Royal Brisbane and Women's Hospital, Brisbane, Australia
| | | | | | | | | | | | | | | | | | | |
Collapse
|
48
|
Stefanuto PH, Zanella D, Vercammen J, Henket M, Schleich F, Louis R, Focant JF. Multimodal combination of GC × GC-HRTOFMS and SIFT-MS for asthma phenotyping using exhaled breath. Sci Rep 2020; 10:16159. [PMID: 32999424 PMCID: PMC7528084 DOI: 10.1038/s41598-020-73408-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 09/16/2020] [Indexed: 11/12/2022] Open
Abstract
Chronic inflammatory lung diseases impact more than 300 million of people worldwide. Because they are not curable, these diseases have a high impact on both the quality of life of patients and the healthcare budget. The stability of patient condition relies mostly on constant treatment adaptation and lung function monitoring. However, due to the variety of inflammation phenotypes, almost one third of the patients receive an ineffective treatment. To improve phenotyping, we evaluated the complementarity of two techniques for exhaled breath analysis: full resolving comprehensive two-dimensional gas chromatography coupled to high-resolution time-of-flight mass spectrometry (GC × GC-HRTOFMS) and rapid screening selected ion flow tube MS (SIFT-MS). GC × GC-HRTOFMS has a high resolving power and offers a full overview of sample composition, providing deep insights on the ongoing biology. SIFT-MS is usually used for targeted analyses, allowing rapid classification of samples in defined groups. In this study, we used SIFT-MS in a possible untargeted full-scan mode, where it provides pattern-based classification capacity. We analyzed the exhaled breath of 50 asthmatic patients. Both techniques provided good classification accuracy (around 75%), similar to the efficiency of other clinical tools routinely used for asthma phenotyping. Moreover, our study provides useful information regarding the complementarity of the two techniques.
Collapse
Affiliation(s)
- Pierre-Hugues Stefanuto
- Organic and Biological Analytical Chemistry Group, MOLSYS Research Unit, University of Liège, Allée du 6 Août B6c, 4000, Liège, Belgium.
| | - Delphine Zanella
- Organic and Biological Analytical Chemistry Group, MOLSYS Research Unit, University of Liège, Allée du 6 Août B6c, 4000, Liège, Belgium
| | - Joeri Vercammen
- Interscience, Avenue J.E. Lenoir, Louvain-la-Neuve, Belgium.,Engineering, Industrial Catalysis and Adsorption Technology (INCAT), Ghent University, Ghent, Belgium
| | - Monique Henket
- Pneumology and Allergology, GIGA Research Group, CHU of Liège, University of Liege, Liège, Belgium
| | - Florence Schleich
- Pneumology and Allergology, GIGA Research Group, CHU of Liège, University of Liege, Liège, Belgium
| | - Renaud Louis
- Pneumology and Allergology, GIGA Research Group, CHU of Liège, University of Liege, Liège, Belgium
| | - Jean-François Focant
- Organic and Biological Analytical Chemistry Group, MOLSYS Research Unit, University of Liège, Allée du 6 Août B6c, 4000, Liège, Belgium
| |
Collapse
|
49
|
Abstract
Recent developments in biomarkers relating to the interrelationship of diet, disease and health were surveyed. Most emphasis was placed on biomarkers of deleterious effects, since these are of greatest relevance to the subject of this review. The area of greatest activity was found to be that relating to biomarkers of mutagenic, genotoxic and carcinogenic effects. This is also one of the major areas of concern in considerations of the beneficial and deleterious effects of dietary components, and also the area in which regulatory testing requires studies of the longest duration. A degree of progress has also been made in the identification and development of biomarkers relating to certain classes of target organ toxicity. Biomarkers for other types of toxicity, such as immunotoxicity, neurotoxicity, reproductive toxicity and developmental toxicity, are less developed, and further investigation in these areas is required before a comprehensive biomarker strategy can be established. A criticism that recurs constantly in the biomarker literature is the lack of standardisation in the methods used, and the lack of reference standards for the purposes of validation and quality control. It is encouraging to note the growing acknowledgement of the need for validation of biomarkers and biomarker assays. Some validation studies have already been initiated. This review puts forward proposals for criteria to be used in biomarker validation. More discussion on this subject is required. It is concluded that the use of biomarkers can, in some cases, facilitate the implementation of the Three Rs with respect to the testing of food chemicals and studies on the effects of diet on health. The greatest potential is seen to be in the refinement of animal testing, in which biomarkers could serve as early and sensitive endpoints, in order to reduce the duration of the studies and also reduce the number of animals required. Biomarkers could also contribute to establishing a mechanistic basis for in vitro test systems and to facilitating their validation and acceptance. Finally, the increased information that could result from the incorporation of biomarker determinations into population studies could reduce the need for supplementary animal studies. This review makes a number of recommendations concerning the prioritisation of future activities on dietary biomarkers in relation to the Three Rs. It is emphasised, however, that further discussions will be required among toxicologists, epidemiologists and others researching the relationship between diet and health.
Collapse
Affiliation(s)
- Krys Bottrill
- FRAME, Russell & Burch House, 96–98 North Sherwood Street, Nottingham NG1 4EE, UK
| |
Collapse
|
50
|
Janfaza S, Khorsand B, Nikkhah M, Zahiri J. Digging deeper into volatile organic compounds associated with cancer. Biol Methods Protoc 2019; 4:bpz014. [PMID: 32161807 PMCID: PMC6994028 DOI: 10.1093/biomethods/bpz014] [Citation(s) in RCA: 83] [Impact Index Per Article: 13.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Revised: 09/25/2019] [Indexed: 12/13/2022] Open
Abstract
Volatile organic compounds (VOCs), produced and emitted through the metabolism of cancer cells or the body's immune system, are considered novel cancer biomarkers for diagnostic purposes. Of late, a large number of work has been done to find a relationship between VOCs' signature of body and cancer. Cancer-related VOCs can be used to detect several types of cancers at the earlier stages which in turn provide a significantly higher chance of survival. Here we aim to provide an updated picture of cancer-related VOCs based on recent findings in this field focusing on cancer odor database.
Collapse
Affiliation(s)
- Sajjad Janfaza
- School of Engineering, University of British Columbia, Kelowna, BC, Canada
- Department of Nanobiotechnology, Faculty of Biological Sciences, Tarbiat Modares University, Jalal Ale Ahmad Highway, Tehran 14117, Iran
| | - Babak Khorsand
- Department of Computer Engineering, Faculty of Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
| | - Maryam Nikkhah
- Department of Nanobiotechnology, Faculty of Biological Sciences, Tarbiat Modares University, Jalal Ale Ahmad Highway, Tehran 14117, Iran
| | - Javad Zahiri
- Bioinformatics and Computational Omics Lab (BioCOOL), Department of Biophysics, Faculty of Biological Sciences, Tarbiat Modares University, Jalal Ale Ahmad Highway, Tehran 14117, Iran
| |
Collapse
|