1
|
Arshee MR, Shukla R, Li J, Doha U, Bagchi IC, Ziv-Gal A, Wagoner Johnson AJ. Impact of paraben on uterine collagen: An integrated and targeted Correlative approach using second harmonic generation microscopy, nanoindentation, and atomic force microscopy. J Mech Behav Biomed Mater 2025; 165:106926. [PMID: 39946870 PMCID: PMC11893236 DOI: 10.1016/j.jmbbm.2025.106926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2024] [Revised: 01/19/2025] [Accepted: 01/31/2025] [Indexed: 03/12/2025]
Abstract
This study investigates the structural and mechanical changes in uterine collagen following exposure to propylparaben (PP) using a combined methodology of Second Harmonic Generation (SHG) microscopy, Nanoindentation (NI), and Atomic Force Microscopy (AFM). SHG analysis identified significant disorganization in collagen fibril orientation in the circumferential layer and heterogeneous distribution of regions with elevated forward to backward ratios (F/B) across all uterine layers due to PP exposure. High F/B can indicate multiple potential fibril-level changes like thickened fibrils, higher crosslinking, fibril disorganization - changes not fully decipherable by SHG alone. Recognizing this limitation, the study employs NI and AFM to provide complementary mechanical and nanoscale insights. NI revealed increased indentation modulus in the exposed uteri, suggesting increased stiffness. Co-registration of the indentation response with SHG parameters uncovered that elevated F/B regions show enhanced mechanical stiffness, suggesting a fibrotic transformation following chronic PP exposure. AFM was specifically performed on regions identified by SHG as having low or high F/B, providing the necessary nanoscale resolution to elucidate the structural changes in fibrils that are likely responsible for the observed alterations. AFM confirmed the presence of disordered and entangled collagen fibrils in the circumferential layer in all regions and an increase in fibril diameter in the high F/B regions in the PP-exposed uteri. Together, these findings demonstrate significant alterations in collagen architecture due to PP exposure, revealing disruptions at both the fiber and fibril levels and highlighting the potential for broader applications of the multi-scale, multi-modal approach in collagenous tissue studies.
Collapse
Affiliation(s)
- Mahmuda R Arshee
- Mechanical Science and Engineering, Grainger College of Engineering, University of Illinois at Urbana-Champaign, Champaign, IL, 61820, USA
| | - Ritwik Shukla
- Comparative Biosciences, College of Veterinary Medicine, University of Illinois at Urbana-Champaign, Urbana, IL, 61802, USA
| | - Jie Li
- Comparative Biosciences, College of Veterinary Medicine, University of Illinois at Urbana-Champaign, Urbana, IL, 61802, USA
| | - Umnia Doha
- Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
| | - Indrani C Bagchi
- Comparative Biosciences, College of Veterinary Medicine, University of Illinois at Urbana-Champaign, Urbana, IL, 61802, USA; Biomedical and Translational Sciences, Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Champaign, IL, 61820, USA; Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA; CZ Biohub Chicago, LLC, Chicago, IL, 60642, USA
| | - Ayelet Ziv-Gal
- Comparative Biosciences, College of Veterinary Medicine, University of Illinois at Urbana-Champaign, Urbana, IL, 61802, USA; Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA; CZ Biohub Chicago, LLC, Chicago, IL, 60642, USA
| | - Amy J Wagoner Johnson
- Mechanical Science and Engineering, Grainger College of Engineering, University of Illinois at Urbana-Champaign, Champaign, IL, 61820, USA; Biomedical and Translational Sciences, Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Champaign, IL, 61820, USA; Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA; CZ Biohub Chicago, LLC, Chicago, IL, 60642, USA; Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA.
| |
Collapse
|
2
|
Kontomaris SV, Malamou A, Stylianou A. Development of an accurate simplified approach for data processing in AFM indentation experiments. Micron 2025; 190:103782. [PMID: 39799615 DOI: 10.1016/j.micron.2024.103782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2024] [Revised: 12/29/2024] [Accepted: 12/30/2024] [Indexed: 01/15/2025]
Abstract
Atomic Force Microscopy (AFM) nanoindentation is the most effective method for determining the mechanical properties of soft biological materials and biomaterials at the nanoscale, with significant applications in many areas, including cancer diagnosis. However, a major drawback of this method is the complexity of the experimental procedure and data processing, which requires several calibration steps.To avoid this complexity, the AFM tip is usually approximated as a perfect cone. In this case, F=ch2, where F is the applied force, ℎ is the indentation depth, and c is a constant that depends on both the cone's half-angle and the material's properties. However, since AFM tips are pyramidal with a rounded tip apex (or similar to a truncated cone in some cases), the conical approximation may lead to non-negligible errors. Although equations exist that relate the applied force, indentation depth, and the sample's Young's modulus for real indenters, they are rarely used because they do not directly relate the applied force to the indentation depth (i.e., the fitting process is much more complicated compared to the conical approximation). In this paper, a new, accurate, simplified approach for data processing is proposed, based on fitting the force-indentation data to a quadratic equation of the form: F=c2h2+c1h. It is proven that the parameter c2 is independent of the tip apex properties. On the other hand, the parameter c1 depends on the material properties, the cone's half angle, and the shape and dimensions of the tip apex. Simulated force-indentation data from sphero-conical and blunted pyramidal indenters, along with real experimental data from lung tissues, are processed using the proposed approach. The key result is that Young's modulus can be accurately determined using only the c2 parameter; therefore, tip characterization can be avoided.
Collapse
Affiliation(s)
- S V Kontomaris
- School of Sciences, European University Cyprus, Nicosia 2404, Cyprus; Department of Engineering and Construction, Metropolitan College, Athens 15125, Greece.
| | - A Malamou
- Radar Systems and Remote Sensing Lab of School of Electrical & Computer Engineering of National Technical University of Athens, Athens 15773 , Greece
| | - A Stylianou
- School of Sciences, European University Cyprus, Nicosia 2404, Cyprus.
| |
Collapse
|
3
|
Ríos-Ruíz I, Martínez MA, Peña E. What about the mechanical behaviour and modelling of arteries in radial direction? J Biomech 2025; 182:112500. [PMID: 39919621 DOI: 10.1016/j.jbiomech.2025.112500] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2024] [Revised: 12/07/2024] [Accepted: 01/02/2025] [Indexed: 02/09/2025]
Abstract
Understanding the physiological behaviour of arteries in the radial direction is crucial for establishing a reference point to detect and analyse pathological changes. In this study, the influence of the radial component of the aorta will be investigated by performing experimental tests on porcine aortic tissue in the three main directions of the aorta: circumferential, longitudinal and radial. The results obtained in all directions will be analysed and compared in order to contribute to a comprehensive understanding of the healthy behaviour of the vessel. Our results demonstrate that the aorta exhibits nonlinear behaviour under compression and tensile loading in the radial direction. Moreover, tissue stiffening progresses more prominently under compression compared to tensile loading. We have found that the tensile stiffness in the ATA is higher compared to the other two regions examined. The Neo-Hookean and Demiray models were selected to describe the isotropic contribution when fitting the uniaxial response of the circumferential and longitudinal samples using the GOH model. Neo-Hookean model fall short (R2=0.235) in accurately replicating the observed behaviour of the aorta in the radial direction and Demiray model showing better fitting results (R2=0.994).
Collapse
Affiliation(s)
- Itziar Ríos-Ruíz
- Department of Mechanical Engineering, University of Zaragoza, Spain; Aragón Institute of Engineering Research (I3A), University of Zaragoza, Spain
| | - Miguel A Martínez
- Department of Mechanical Engineering, University of Zaragoza, Spain; Aragón Institute of Engineering Research (I3A), University of Zaragoza, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza, Spain
| | - Estefanía Peña
- Department of Mechanical Engineering, University of Zaragoza, Spain; Aragón Institute of Engineering Research (I3A), University of Zaragoza, Spain; CIBER de Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Zaragoza, Spain.
| |
Collapse
|
4
|
Oude Vrielink MA, Timmermans PHM, van de Wetering B, Hovenkamp R, van der Sluis O. Computational modeling of vascular tissue damage for the development of safe interventional devices. J Mech Behav Biomed Mater 2025; 163:106818. [PMID: 39637527 DOI: 10.1016/j.jmbbm.2024.106818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2024] [Revised: 11/02/2024] [Accepted: 11/15/2024] [Indexed: 12/07/2024]
Abstract
During intravascular procedures, medical devices interact mechanically with vascular tissue. The device design faces a trade-off: although a high bending stiffness improves its maneuvrability and deliverability, it may also trigger excessive supra-physiological loading that may result in tissue damage. In particular, the collagen fibers in vascular walls are load-bearing but may rupture on a microscopic scale due to mechanical interaction. When the mechanical load increases even further, tissue rupture or puncture occurs. To mitigate tissue damage, the current work focusses on the development of computational Finite Element (FE) based models wherein state-of-the-art constitutive tissue models are applied toward the design of safe devices. Several experiments are presented for tissue characterization in which device-mimicking indenters are pressed onto a porcine tissue. In these experiments, the Mullins effect, which is related to tissue damage, is observed. Consequently, the mechanical behavior of tissue, including the evolution of damage-induced energy dissipation, is accurately described by adopting a hyperelastic model incorporating the damage approach by Weisbecker et al. (2012). From the experimentally validated computational model, a novel design criterion is established, which allows for safe device development. Furthermore, an energy density criterion for the onset of puncture is proposed. With these tools, several frequently used work-horse guidewires are numerically evaluated.
Collapse
Affiliation(s)
| | | | | | | | - O van der Sluis
- Philips Innovation & Strategy, Netherlands; Eindhoven University of Technology, Netherlands.
| |
Collapse
|
5
|
Allum Saib Z, Abed F, Ghayesh MH, Amabili M. Interaction of a self-expandable stent with the arterial wall in the presence of hypocellular and calcified plaques. Biomech Model Mechanobiol 2025; 24:77-91. [PMID: 39369168 DOI: 10.1007/s10237-024-01896-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2024] [Accepted: 09/25/2024] [Indexed: 10/07/2024]
Abstract
Self-expandable stents manufactured from nitinol alloys are commonly utilized alongside traditional balloon-expandable stents to provide scaffolding to stenosed arteries. However, a significant limitation hampering stent efficacy is restenosis, triggered by neointimal hyperplasia and resulting in the loss of gain in lumen size, post-intervention. In this study, a nonlinear finite element model was developed to simulate stent crimping and expansion and its interaction with the surrounding vessel in the presence of a plaque. The main aim was to determine contact pressures and forces induced at the interface between an artery wall with hypocellular and calcified plaques and an expanded stent. The results demonstrated the drawbacks of plaque calcification, which triggered a sharp contact pressure and radial force surge at the interface as well as a significant rise in von Mises stress within the vessel, potentially leading to rupture and restenosis. A regression line was then established to relate hypocellular and calcified plaques. The adjusted coefficient of determination indicated a good correlation between contact pressures for calcified and hypocellular plaque models. Regarding the directionality of wall properties, contact pressure and force observations were not significantly different between isotropic and anisotropic arteries. Moreover, variations in friction coefficients did not substantially affect the interfacial contact pressures.
Collapse
Affiliation(s)
- Zubeir Allum Saib
- Biomedical Engineering Graduate Program, American University of Sharjah, P.O. Box 26666, Sharjah, United Arab Emirates
| | - Farid Abed
- Department of Civil Engineering, American University of Sharjah, P.O. Box 26666, Sharjah, United Arab Emirates.
| | - Mergen H Ghayesh
- School of Electrical and Mechanical Engineering, University of Adelaide, Adelaide, South Australia, Australia
| | - Marco Amabili
- School of Engineering, Westlake University, Zhejiang Province, Hangzhou, People's Republic of China
- Department of Mechanical Engineering, McGill University, Montreal, Canada
| |
Collapse
|
6
|
Yusefi M, Agrafiotis E, Regitnig P, Laufer G, Sommer G, Holzapfel GA, Mächler H. TEVAR versus open aortic arch replacement in ex vivo perfused human thoracic aortas. Acta Biomater 2025; 192:140-150. [PMID: 39674239 DOI: 10.1016/j.actbio.2024.12.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2024] [Revised: 11/14/2024] [Accepted: 12/04/2024] [Indexed: 12/16/2024]
Abstract
This study aims to assess the outcomes of therapeutic options for aortic arch pathologies by comparing thoracic endovascular aortic repair (TEVAR) with open arch replacement (OAR) using woven polyester grafts from a mechanical and biomechanical perspective, with emphasis on ex vivo perfused human thoracic aortas reproducing heart rate and stroke volume conditions. Eleven non-diseased thoracic aortas from human cadavers were divided into TEVAR (n=5) and OAR (n=6) and tested using a custom-built mock circulation loop. Pressure, diameter, and stroke volume were monitored during perfusion before and after the intervention. Samples undergoing TEVAR showed a higher ascending systolic pressure post-intervention than OAR (TEVAR: 137±9mmHg vs OAR: 126±6mmHg, p=0.017). After the intervention, a significant discrepancy in the mean pressure differences between the ascending and descending aorta ΔP was observed (TEVAR: 9±3mmHg vs OAR: 1±2mmHg, p=0.004). Input impedance at zero frequency, approximating Windkessel resistance, was higher for TEVAR than for OAR (TEVAR: 1.78±0.04 vs OAR: 1.66±0.03mmHgs/ml, p=0.004). A correlation was found between the resistance and the negative peak of the time-normalized wave intensity analysis (Kendall's coefficient τ=-0.35 and p=0.023). Another correlation was observed between resistance and ΔP (τ=0.51, p=0.001). Looking at the replication of heart rate and stroke volume over the course of the study, the observed differences can largely be attributed to the type of intervention. The results suggest that TEVAR has adverse effects compared to OAR, particularly with regard to left ventricular afterload. Clinicians should consider the possibility of increased afterload and altered wave dynamics when deciding on TEVAR, particularly in patients with pre-existing impaired cardiovascular conditions.
Collapse
Affiliation(s)
- Masoud Yusefi
- Institute of Biomechanics, Graz University of Technology, Austria
| | - Emmanouil Agrafiotis
- Institute of Biomechanics, Graz University of Technology, Austria; Biomedical Engineering, University of Michigan, USA
| | - Peter Regitnig
- Diagnostic and Research Institute of Pathology, Medical University of Graz, Austria
| | - Günther Laufer
- Division of Cardiac Surgery, Medical University of Graz, Austria
| | - Gerhard Sommer
- Institute of Biomechanics, Graz University of Technology, Austria.
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Austria; Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), Trondheim, Norway.
| | - Heinrich Mächler
- Division of Cardiac Surgery, Medical University of Graz, Austria
| |
Collapse
|
7
|
Doukas P, Hruschka B, Bassett C, Buhl EM, Simon F, Saraber P, Jacobs MJ, Uhl C, Schurgers LJ, Gombert A. Distribution and Maturity of Medial Collagen Fibers in Thoracoabdominal Post-Dissection Aortic Aneurysms: A Comparative Study of Marfan and Non-Marfan Patients. Int J Mol Sci 2024; 26:14. [PMID: 39795873 PMCID: PMC11720456 DOI: 10.3390/ijms26010014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2024] [Revised: 12/12/2024] [Accepted: 12/16/2024] [Indexed: 01/13/2025] Open
Abstract
Thoracoabdominal aortic aneurysms (TAAAs) are rare but serious conditions characterized by dilation of the aorta characterized by remodeling of the vessel wall, with changes in the elastin and collagen content. Individuals with Marfan syndrome have a genetic predisposition for elastic fiber fragmentation and elastin degradation and are prone to early aneurysm formation and progression. Our objective was to analyze the medial collagen characteristics through histological, polarized light microscopy, and electron microscopy methods across the thoracic and abdominal aorta in twenty-five patients undergoing open surgical repair, including nine with Marfan syndrome. While age at surgery differed significantly between the groups, maximum aortic diameter and aneurysm extent did not. Collagen content increased from thoracic to infrarenal segments in both cohorts, with non-Marfan patients exhibiting higher collagen percentages, notably in the infrarenal aorta (729.3 nm vs. 1068.3 nm, p = 0.02). Both groups predominantly displayed mature collagen fibers, with the suprarenal segment containing the highest proportion of less mature fibers. Electron microscopy revealed comparable collagen fibril diameters across segments irrespective of Marfan status. Our findings underscore non-uniform histological patterns in TAAAs and suggest that ECM remodeling involves mature collagen deposition, albeit with lower collagen content observed in the infrarenal aorta of Marfan patients.
Collapse
Affiliation(s)
- Panagiotis Doukas
- Department of Vascular Surgery, RWTH Aachen University Hospital, 52074 Aachen, Germany; (B.H.); (C.B.); (M.J.J.); (C.U.); (A.G.)
| | - Bernhard Hruschka
- Department of Vascular Surgery, RWTH Aachen University Hospital, 52074 Aachen, Germany; (B.H.); (C.B.); (M.J.J.); (C.U.); (A.G.)
| | - Cathryn Bassett
- Department of Vascular Surgery, RWTH Aachen University Hospital, 52074 Aachen, Germany; (B.H.); (C.B.); (M.J.J.); (C.U.); (A.G.)
| | - Eva Miriam Buhl
- Institute of Pathology, Electron Microscopy Facility, RWTH Aachen University Hospital, 52074 Aachen, Germany
| | - Florian Simon
- Clinic for Vascular and Endovascular Surgery, University Hospital Duesseldorf, Heinrich-Heine-University Duesseldorf, 40225 Düsseldorf, Germany;
| | - Pepijn Saraber
- Department of Biochemistry, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, 6200 MD Maastricht, The Netherlands; (P.S.); (L.J.S.)
| | - Michael Johan Jacobs
- Department of Vascular Surgery, RWTH Aachen University Hospital, 52074 Aachen, Germany; (B.H.); (C.B.); (M.J.J.); (C.U.); (A.G.)
| | - Christian Uhl
- Department of Vascular Surgery, RWTH Aachen University Hospital, 52074 Aachen, Germany; (B.H.); (C.B.); (M.J.J.); (C.U.); (A.G.)
| | - Leon J. Schurgers
- Department of Biochemistry, Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, 6200 MD Maastricht, The Netherlands; (P.S.); (L.J.S.)
| | - Alexander Gombert
- Department of Vascular Surgery, RWTH Aachen University Hospital, 52074 Aachen, Germany; (B.H.); (C.B.); (M.J.J.); (C.U.); (A.G.)
| |
Collapse
|
8
|
Wang X, Ghayesh MH, Li J, Kotousov A, Zander AC, Dawson JA, Psaltis PJ. Impact of Geometric Attributes on Abdominal Aortic Aneurysm Rupture Risk: An In Vivo FSI-Based Study. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2024; 40:e3884. [PMID: 39529502 DOI: 10.1002/cnm.3884] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2024] [Revised: 09/02/2024] [Accepted: 10/27/2024] [Indexed: 11/16/2024]
Abstract
Reported in this paper is a cutting-edge computational investigation into the influence of geometric characteristics on abdominal aortic aneurysm (AAA) rupture risk, beyond the traditional measure of maximum aneurysm diameter. A Comprehensive fluid-structure interaction (FSI) analysis was employed to assess risk factors in a range of patient scenarios, with the use of three-dimensional (3D) AAA models reconstructed from patient-specific aortic data and finite element method. Wall shear stress (WSS), and its derivatives such as time-averaged WSS (TAWSS), oscillatory shear index (OSI), relative residence time (RRT) and transverse WSS (transWSS) offer insights into the force dynamics acting on the AAA wall. Emphasis is placed on these WSS-based metrics and seven key geometric indices. By correlating these geometric discrepancies with biomechanical phenomena, this study highlights the novel and profound impact of geometry on risk prediction. This study demonstrates the necessity of a multidimensional assessment approach, future efforts should complement these findings with experimental validations for an applicable approach for clinical use.
Collapse
Affiliation(s)
- Xiaochen Wang
- School of Electrical and Mechanical Engineering, University of Adelaide, Adelaide, South Australia, Australia
| | - Mergen H Ghayesh
- School of Electrical and Mechanical Engineering, University of Adelaide, Adelaide, South Australia, Australia
| | - Jiawen Li
- School of Electrical and Mechanical Engineering, University of Adelaide, Adelaide, South Australia, Australia
| | - Andrei Kotousov
- School of Electrical and Mechanical Engineering, University of Adelaide, Adelaide, South Australia, Australia
| | - Anthony C Zander
- School of Electrical and Mechanical Engineering, University of Adelaide, Adelaide, South Australia, Australia
| | - Joseph A Dawson
- Department of Vascular & Endovascular Surgery, Royal Adelaide Hospital, Adelaide, South Australia, Australia
- Trauma Surgery Unit, Royal Adelaide Hospital, Adelaide, South Australia, Australia
- Adelaide Medical School, University of Adelaide, Adelaide, South Australia, Australia
| | - Peter J Psaltis
- Adelaide Medical School, University of Adelaide, Adelaide, South Australia, Australia
- Vascular Research Centre, Lifelong Health Theme, South Australian Health & Medical Research Institute (SAHMRI), Adelaide, South Australia, Australia
- Department of Cardiology, Central Adelaide Local Health Network, Adelaide, South Australia, Australia
| |
Collapse
|
9
|
Moghadasi K, Ghayesh MH, Li J, Hu E, Amabili M, Żur KK, Fitridge R. Nonlinear biomechanical behaviour of extracranial carotid artery aneurysms in the framework of Windkessel effect via FSI technique. J Mech Behav Biomed Mater 2024; 160:106760. [PMID: 39366083 DOI: 10.1016/j.jmbbm.2024.106760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2024] [Revised: 08/29/2024] [Accepted: 09/28/2024] [Indexed: 10/06/2024]
Abstract
Extracranial carotid artery aneurysms (ECCA) lead to rupture and neurologic symptoms from embolisation, with potentially fatal outcomes. Investigating the biomechanical behaviour of EECA with blood flow dynamics is crucial for identifying regions more susceptible to rupture. A coupled three-dimensional (3D) Windkessel-framework and hyperelastic fluid-structure interaction (FSI) analysis of ECCAs with patient-specific geometries, was developed in this paper with a particular focus on hemodynamic parameters and the arterial wall's biomechanical response. The blood flow has been modelled as non-Newtonian, pulsatile, and turbulent. The biomechanical characteristics of the aneurysm and artery are characterised employing a 5-parameter Mooney-Rivlin hyperelasticity model. The Windkessel effect is also considered to efficiently simulate pressure profile of the outlets and to capture the dynamic changes over the cardiac cycle. The study found the aneurysm carotid artery exhibited the high levels of pressure, wall shear stress (WSS), oscillatory shear index (OSI), and relative residence time (RRT) compared to the healthy one. The deformation of the arterial wall and the corresponding von Mises (VM) stress were found significantly increased in aneurysm cases, in comparison to that of no aneurysm cases, which strongly correlated with the hemodynamic characteristics of the blood flow and the geometric features of the aneurysms. This escalation would intensify the risk of aneurysm wall rupture. These findings have critical implications for enhancing treatment strategies for patients with extracranial aneurysms.
Collapse
Affiliation(s)
- Kaveh Moghadasi
- School of Electrical and Mechanical Engineering, University of Adelaide, Adelaide, South Australia 5005, Australia.
| | - Mergen H Ghayesh
- School of Electrical and Mechanical Engineering, University of Adelaide, Adelaide, South Australia 5005, Australia.
| | - Jiawen Li
- School of Electrical and Mechanical Engineering, University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Eric Hu
- School of Electrical and Mechanical Engineering, University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Marco Amabili
- School of Engineering, Westlake University, Zhejiang province, PR China; Department of Mechanical Engineering, McGill University, Montreal, Canada
| | - Krzysztof Kamil Żur
- Faculty of Mechanical Engineering, Bialystok University of Technology, Bialystok, 15-351, Poland
| | - Robert Fitridge
- Vascular and Endovascular Service, Royal Adelaide Hospital, Adelaide, Australia; Discipline of Surgery, University of Adelaide, Adelaide, Australia; Basil Hetzel Institute for Translational Health Research, The Queen Elizabeth Hospital, Adelaide, Australia
| |
Collapse
|
10
|
Arshee MR, Shukla R, Li J, Bagchi IC, Ziv-Gal A, Johnson AJW. Impact of Paraben on Uterine Collagen: An Integrated and Targeted Correlative Approach Using Second Harmonic Generation Microscopy, Nanoindentation, and Atomic Force Microscopy. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2024:2024.11.06.622338. [PMID: 39574727 PMCID: PMC11581003 DOI: 10.1101/2024.11.06.622338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/02/2024]
Abstract
This study investigates the structural and mechanical changes in uterine collagen following exposure to propylparaben (PP), using a combined methodology of Second Harmonic Generation (SHG) microscopy, Nanoindentation (NI), and Atomic Force Microscopy (AFM). SHG analysis identified significant disorganization in collagen fibril orientation in the circumferential layer and heterogeneous distribution of regions with elevated forward to backward ratios (F/B) across all uterine layers due to PP exposure. High F/B can indicate multiple potential fibril-level changes like thickened fibrils, higher crosslinking, fibril disorganization - changes not fully decipherable by SHG alone. Recognizing this limitation, the study employs NI and AFM to provide complementary mechanical and nanoscale insights. NI revealed increased indentation modulus in the exposed uteri, suggesting increased stiffness. Co-registration of the indentation response with SHG parameters uncovered that elevated F/B regions show enhanced mechanical stiffness, suggesting a fibrotic transformation following PP exposure. AFM was specifically performed on regions identified by SHG as having low or high F/B, providing the necessary nanoscale resolution to elucidate the structural changes in fibrils that are likely responsible for the observed alterations. This approach confirmed the presence of disordered and entangled collagen fibrils in the circumferential layer in all regions and an increase in fibril diameter in the high F/B regions in the exposed uteri. Together, these findings demonstrate significant alterations in collagen architecture due to PP exposure, revealing disruptions at both the fiber and fibril levels and highlighting the potential for broader applications of the multi-scale, multi-modal approach in collagenous tissue studies.
Collapse
Affiliation(s)
- Mahmuda R Arshee
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Champaign, IL, 61820, USA
| | - Ritwik Shukla
- Department of Comparative Biosciences, University of Illinois at Urbana-Champaign, Urbana, IL, 61802, USA
| | - Jie Li
- Department of Comparative Biosciences, University of Illinois at Urbana-Champaign, Urbana, IL, 61802, USA
| | - Indrani C Bagchi
- Department of Comparative Biosciences, University of Illinois at Urbana-Champaign, Urbana, IL, 61802, USA
- Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Champaign, IL 61820, USA
- Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
- CZ Biohub Chicago, LLC, Chicago, Illinois 60642
| | - Ayelet Ziv-Gal
- Department of Comparative Biosciences, University of Illinois at Urbana-Champaign, Urbana, IL, 61802, USA
- CZ Biohub Chicago, LLC, Chicago, Illinois 60642
| | - A J Wagoner Johnson
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Champaign, IL, 61820, USA
- Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, Champaign, IL 61820, USA
- Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
- CZ Biohub Chicago, LLC, Chicago, Illinois 60642
| |
Collapse
|
11
|
Zhang W, Jadidi M, Razian SA, Holzapfel GA, Kamenskiy A, Nordsletten DA. A viscoelastic constitutive framework for aging muscular and elastic arteries. Acta Biomater 2024; 188:223-241. [PMID: 39303831 PMCID: PMC11844772 DOI: 10.1016/j.actbio.2024.09.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2024] [Revised: 09/11/2024] [Accepted: 09/12/2024] [Indexed: 09/22/2024]
Abstract
The evolution of arterial biomechanics and microstructure with age and disease plays a critical role in understanding the health and function of the cardiovascular system. Accurately capturing these adaptative processes and their effects on the mechanical environment is critical for predicting arterial responses. This challenge is exacerbated by the significant differences between elastic and muscular arteries, which have different structural organizations and functional demands. In this study, we aim to shed light to these adaptive processes by comparing the viscoelastic mechanics of autologous thoracic aortas (TA) and femoropopliteal arteries (FPA) in different age groups. We have extended our fractional viscoelastic framework, originally developed for FPA, to both types of arteries. To evaluate this framework, we analyzed experimental mechanical data from TA and FPA specimens from 21 individuals aged 13 to 73 years. Each specimen was subjected to a multi-ratio biaxial mechanical extension and relaxation test complemented by bidirectional histology to quantify the structural density and microstructural orientations. Our new constitutive model accurately captured the mechanical responses and microstructural differences of the tissues and closely matched the experimentally measured densities. It was found that the viscoelastic properties of collagen and smooth muscle cells (SMCs) in both the FPA and TA remained consistent with age, but the viscoelasticity of the SMCs in the FPA was twice that of the TA. Additionally, changes in collagen nonlinearity with age were similar in both TA and FPA. This model provides valuable insights into arterial mechanophysiology and the effects of pathological conditions on vascular biomechanics. STATEMENT OF SIGNIFICANCE: Developing durable treatments for arterial diseases necessitates a deeper understanding of how mechanical properties evolve with age in response to mechanical environments. In this work, we developed a generalized viscoelastic constitutive model for both elastic and muscular arteries and analyzed both the thoracic aorta (TA) and the femoropopliteal artery (FPA) from 21 donors aged 13 to 73. The derived parameters correlate well with histology, allowing further examination of how viscoelasticity evolves with age. Correlation between the TA and FPA of the same donors suggest that the viscoelasticity of the FPA may be influenced by the TA, necessitating more detailed analysis. In summary, our new model proves to be a valuable tool for studying arterial mechanophysiology and exploring pathological impacts.
Collapse
Affiliation(s)
- Will Zhang
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA.
| | - Majid Jadidi
- Department of Biomechanics, University of Nebraska at Omaha, NE, USA.
| | | | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Austria; Department of Structural Engineering, Norwegian University of Science and Technology, Trondheim, Norway.
| | - Alexey Kamenskiy
- Department of Biomechanics, University of Nebraska at Omaha, NE, USA.
| | - David A Nordsletten
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI, USA; Division of Biomedical Engineering and Imaging Sciences, Department of Biomedical Engineering, King's College London, UK.
| |
Collapse
|
12
|
Kontomaris SV, Malamou A, Stylianou A. Accurate Modelling of AFM Force-Indentation Curves with Blunted Indenters at Small Indentation Depths. MICROMACHINES 2024; 15:1209. [PMID: 39459083 PMCID: PMC11509629 DOI: 10.3390/mi15101209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2024] [Revised: 09/24/2024] [Accepted: 09/27/2024] [Indexed: 10/28/2024]
Abstract
When testing biological samples with atomic force microscopy (AFM) nanoindentation using pyramidal indenters, Sneddon's equation is commonly used for data processing, approximating the indenter as a perfect cone. While more accurate models treat the AFM tip as a blunted cone or pyramid, these are complex and lack a direct relationship between applied force and indentation depth, complicating data analysis. This paper proposes a new equation derived from simple mathematical processes and physics-based criteria. It is accurate for small indentation depths and serves as a viable alternative to complex classical approaches. The proposed equation has been validated for ℎ < 3R (where h is the indentation depth and R is the tip radius) and confirmed through simulations with blunted conical and pyramidal indenters, as well as experiments on prostate cancer cells. It is a reliable method for experiments where the tip radius cannot be ignored, such as in shallow indentations on thin samples to avoid substrate effects.
Collapse
Affiliation(s)
- Stylianos Vasileios Kontomaris
- Cancer Mechanobiology and Applied Biophysics Group, School of Sciences, European University Cyprus, 2404 Nicosia, Cyprus;
| | - Anna Malamou
- School of Electrical and Computer Engineering, National Technical University of Athens, 15773 Athens, Greece;
| | - Andreas Stylianou
- Cancer Mechanobiology and Applied Biophysics Group, School of Sciences, European University Cyprus, 2404 Nicosia, Cyprus;
| |
Collapse
|
13
|
Han Y, Zhang L, Kong L, Wang G, Ye Z. Investigating the relationship between residual stress and micromechanical properties of blood vessels using atomic force microscopy. Microsc Res Tech 2024; 87:1678-1692. [PMID: 38500314 DOI: 10.1002/jemt.24552] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 03/05/2024] [Accepted: 03/06/2024] [Indexed: 03/20/2024]
Abstract
The magnitude of vascular residual stress, an inherent characteristic exclusive to the vasculature, exhibits a strong correlation with vascular compliance, tensile resistance, vascular rigidity, and vascular remodeling subsequent to vascular transplantation. Vascular residual stress can be quantified by evaluating the magnitude of the opening angle within the vascular ring. For decellularized vessels, the vascular ring's opening angle diminishes, consequently reducing residual stress. The decellularization process induces a laxity in the vascular fiber structure within decellularized vessels. To investigate the interrelation between the magnitude of residual stress and the microstructure as well as mechanical properties of elastin and collagen within blood vessels, this study employed fresh blood vessels, stress-relieved vessels, and sections of decellularized blood vessels. Structural scanning and force map experiments on the surface of the sections were conducted using atomic force microscopy (AFM). The findings revealed well-organized arrangements of elastin and collagen within fresh vessels, wherein the regularity of collagen and elastin exhibited variability as residual stress declined. Furthermore, both stress-relieved and decellularized vessel sections exhibited a reduction in the mean Young's modulus to varying extents in comparison to fresh vessels. The validity of our experimental results was further corroborated through finite element simulations. Hence, residual stress assumes a crucial role in upholding the structural stability of blood vessels, and the intricate association between residual stress and the microstructural and micromechanical properties of blood vessels holds significant implications for comprehending the impact of vascular diseases on vascular structure and advancing the development of biomimetic artificial blood vessels that replicate residual stress. RESEARCH HIGHLIGHTS: In this inquiry, we scrutinized the interconnection amid vascular residual stress and the microscale and nanoscale aspects of vascular structure and mechanical function, employing AFM. We ascertained that residual stress assumes a pivotal role in upholding vascular microstructure and mechanical attributes. The experimental outcomes were subsequently validated through finite element simulation.
Collapse
Affiliation(s)
- Yibo Han
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, College of Bioengineering, Chongqing University, Chongqing, People's Republic of China
| | - Liyuan Zhang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, College of Bioengineering, Chongqing University, Chongqing, People's Republic of China
| | - Lingwen Kong
- Department of Cardiothoracic Surgery, Central Hospital of Chongqing University, Chongqing Emergency Medical Center, People's Republic of China
| | - Guixue Wang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, College of Bioengineering, Chongqing University, Chongqing, People's Republic of China
- JinFeng Laboratory, Chongqing, People's Republic of China
| | - Zhiyi Ye
- Key Laboratory of Biorheological Science and Technology, Ministry of Education, State and Local Joint Engineering Laboratory for Vascular Implants, College of Bioengineering, Chongqing University, Chongqing, People's Republic of China
- JinFeng Laboratory, Chongqing, People's Republic of China
| |
Collapse
|
14
|
Guo X, Yu H, Wang L, Zhai Y, Li J, Tang D, Sun H. Layer-specific biomechanical and histological properties of normal and dissected human ascending aortas. Heliyon 2024; 10:e34646. [PMID: 39816329 PMCID: PMC11734068 DOI: 10.1016/j.heliyon.2024.e34646] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2024] [Revised: 06/22/2024] [Accepted: 07/12/2024] [Indexed: 01/18/2025] Open
Abstract
Recent studies have attempted to characterize the layer-specific mechanical and microstructural properties of the aortic tissues in either normal or pathological state to understand its structural-mechanical property relationships. However, layer-specific tissue mechanics and compositions of normal and dissected ascending aortas have not been thoroughly compared with a statistical conclusion obtained. Eighteen ascending aortic specimens were harvested from 13 patients with type A aortic dissection and 5 donors without aortic diseases, with each specimen further excised to obtain three tissue samples including an intact wall, an intima-media layer and an adventitia layer. For each tissue sample, biaxial tensile testing was performed to obtain the experimental stress-stretch ratio data, which were further fed into the Fung-type model to quantify the tissue stiffness, and Elastin Van Gieson stain and Masson's trichrome stain were employed to quantify the elastic and collagen fiber densities. Statistical analyses were performed to determine whether any significant differences exist in mechanical properties and compositions between diseased and normal aortic tissues. The tissue stiffness of intima-media samples was significant higher in diseased group than that of normal group in longitudinal direction at the stretch ratio 1.30 (p = 0.0068), while no significant differences were found in the other direction or other tissue types. Even though there was no significant difference in elastic or collagen fiber densities between two groups, the diseased group generally had lower elastic fiber density, but higher collagen fiber density for all three tissue layers. Compared to normal aortic tissues, the elastic fiber density of the intima-media layer in the dissected aortic tissue was lower, while its tissue stiffness was significantly higher, indicating the tissue stiffness of the intima-media layer could be a potential indicator for aortic dissection.
Collapse
Affiliation(s)
- Xiaoya Guo
- School of Science, Nanjing University of Posts and Telecommunications, Nanjing, 210023, China
| | - Han Yu
- School of Mechanical, Medical and Process Engineering, Queensland University of Technology, Brisbane, 4000, Australia
| | - Liang Wang
- School of Biological Science and Medical Engineering, Southeast University, Nanjing, 211189, China
| | - Yali Zhai
- Department of Pathophysiology, Nanjing Medical University, Nanjing, 211166, China
| | - Jiantao Li
- Department of Pathophysiology, Nanjing Medical University, Nanjing, 211166, China
| | - Dalin Tang
- School of Biological Science and Medical Engineering, Southeast University, Nanjing, 211189, China
- Mathematical Sciences Department, Worcester Polytechnic Institute, Worcester, MA, 01609, USA
| | - Haoliang Sun
- Department of Cardiovascular Surgery, First Affiliated Hospital of Nanjing Medical University, Nanjing, 210029, China
| |
Collapse
|
15
|
Zhao L, Sang J, Sun L, Li F, Xiang H. Identification of Vivo Material Parameters of Arterial Wall Based on Improved Niching Genetic Algorithm and Neural Networks. INTERNATIONAL JOURNAL OF COMPUTATIONAL METHODS 2024; 21. [DOI: 10.1142/s0219876223500391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2025]
Abstract
Cardiovascular diseases are seriously threatening human health and the incidence rate is high. Many scholars are devoted to studying arterial mechanical properties and material parameters. In this study, the bovine artery was selected as the experimental object and the uniaxial tensile test was carried out by cutting the specimens along its axial, circumferential and [Formula: see text] directions. The finite element software ABAQUS and hyperelastic Holzapfel Gasser Ogden (HGO) constitutive model were used to simulate the experimental process. Niche technology is introduced on the basis of genetic algorithm, and the program of Improved Niche Genetic Algorithm for material parameter identification is compiled based on Python language. In addition, BP Neural Network was constructed based on Tensorflow mathematical system. The material parameters of the constitutive model of bovine artery in different directions were identified by finite element method and experimental data. The results show that Improved Niche Genetic Algorithm and Neural Network, respectively, combined with finite element are both effective and accurate methods for predicting the parameters of arterial vascular hyperelastic materials, which can provide reference and help for the study of arterial vascular mechanical properties.
Collapse
Affiliation(s)
- Luming Zhao
- School of Mechanical Engineering, Hebei University of Technology, Tianjin 300401, P. R. China
| | - Jianbing Sang
- School of Mechanical Engineering, Hebei University of Technology, Tianjin 300401, P. R. China
| | - Lifang Sun
- School of Mechanical Engineering, Hebei University of Technology, Tianjin 300401, P. R. China
- Department of Cardiology, Hospital of Hebei University of Technology, Tianjin 300401, P. R. China
| | - Fengtao Li
- School of Mechanical Engineering, Hebei University of Technology, Tianjin 300401, P. R. China
| | - Huaxin Xiang
- School of Mechanical Engineering, Hebei University of Technology, Tianjin 300401, P. R. China
| |
Collapse
|
16
|
Amabili M, Franchini G, Garziera R. Experimental characterization of residual deformations in human descending thoracic aortas. J Mech Behav Biomed Mater 2024; 153:106492. [PMID: 38479211 DOI: 10.1016/j.jmbbm.2024.106492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 02/18/2024] [Accepted: 03/01/2024] [Indexed: 03/26/2024]
Abstract
The effect of residual stresses on the deformation of human aortas under pulsatile pressure is relevant. Experimental measurements of residual deformations are necessary to characterize residual stresses in human aortas. For this reason, an experimental study is carried out. In the present study, longitudinal and circumferential strips from descending thoracic aortas obtained from 21 donors, harvested during organ donation explant, underwent residual deformation measurements. The intact wall and the three separated layers were tested in both directions, resulting in 8 tests per donor, which gives a relevant set of experimental data for further studies. Results show significant residual deformations both in circumferential and longitudinal directions, which are compatible with a significantly compressed intima in the unloaded aorta. In particular, the measured mean effective curvature was -0.193 ± 0.064 (1/mm) for the circumferential strips and -0.076 ± 0.030 (1/mm) for longitudinal strips of the full wall. The effects of age and gender were also investigated.
Collapse
Affiliation(s)
- Marco Amabili
- School of Engineering, Westlake University, Hangzhou, Zhejiang province, PR China; Department of Mechanical Engineering, McGill University, Montreal, Canada.
| | - Giulio Franchini
- Advanced Material Research Center, Technology Innovation Institute, Abu Dhabi, United Arab Emirates
| | - Rinaldo Garziera
- Dipartimento di Ingegneria ed Architettura, University of Parma, Parma, Italy
| |
Collapse
|
17
|
Pukaluk A, Sommer G, Holzapfel GA. Multimodal experimental studies of the passive mechanical behavior of human aortas: Current approaches and future directions. Acta Biomater 2024; 178:1-12. [PMID: 38401775 DOI: 10.1016/j.actbio.2024.02.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Revised: 02/14/2024] [Accepted: 02/15/2024] [Indexed: 02/26/2024]
Abstract
Cardiovascular diseases are the leading cause of death worldwide and include, among others, critical conditions of the aortic wall. Importantly, such critical conditions require effective diagnosis and treatment, which are not yet accurate enough. However, they could be significantly strengthened with predictive material models of the aortic wall. In particular, such predictive models could support surgical decisions, preoperative planning, and estimation of postoperative tissue remodeling. However, developing a predictive model requires experimental data showing both structural parameters and mechanical behavior. Such experimental data can be obtained using multimodal experiments. This review therefore discusses the current approaches to multimodal experiments. Importantly, the strength of the aortic wall is determined primarily by its passive components, i.e., mainly collagen, elastin, and proteoglycans. Therefore, this review focuses on multimodal experiments that relate the passive mechanical behavior of the human aortic wall to the structure and organization of its passive components. In particular, the multimodal experiments are classified according to the expected results. Multiple examples are provided for each experimental class and summarized with highlighted advantages and disadvantages of the method. Finally, future directions of multimodal experiments are envisioned and evaluated. STATEMENT OF SIGNIFICANCE: Multimodal experiments are innovative approaches that have gained interest very quickly, but also recently. This review presents therefore a first clear summary of groundbreaking research in the field of multimodal experiments. The benefits and limitations of various types of multimodal experiments are thoroughly discussed, and a comprehensive overview of possible results is provided. Although this review focuses on multimodal experiments performed on human aortic tissues, the methods used and described are not limited to human aortic tissues but can be extended to other soft materials.
Collapse
Affiliation(s)
- Anna Pukaluk
- Institute of Biomechanics, Graz University of Technology, Austria
| | - Gerhard Sommer
- Institute of Biomechanics, Graz University of Technology, Austria
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Austria; Department of Structural Engineering (NTNU), Trondheim, Norway.
| |
Collapse
|
18
|
He F, Li M, Wang X, Hua L, Guo T. Numerical investigation of quantitative pulmonary pressure ratio in different degrees of stenosis. MATHEMATICAL BIOSCIENCES AND ENGINEERING : MBE 2024; 21:1806-1818. [PMID: 38454661 DOI: 10.3934/mbe.2024078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/09/2024]
Abstract
BACKGROUND Pulmonary artery stenosis endangers people's health. Quantitative pulmonary pressure ratio (QPPR) is very important for clinicians to quickly diagnose diseases and develop treatment plans. OBJECTIVE Our purpose of this paper is to investigate the effects of different degrees (50% and 80%) of pulmonary artery stenosis on QPPR. METHODS An idealized model is established based on the normal size of human pulmonary artery. The hemodynamic governing equations are solved using fluid-structure interaction. RESULTS The results show that the QPPR decreases with the increase of stenosis degree, and it is closely related to the pressure drop at both ends of stenosis. Blood flow velocity and wall shear stress are sensitive to the stenosis degree. When the degree of stenosis is 80%, the amplitude of changes of blood flow velocity and wall shear stress at both ends of stenosis is lower. CONCLUSIONS The results suggest that the degree of pulmonary artery stenosis has a significant impact on QPPR and hemodynamic changes. This study lays a theoretical foundation for further study of QPPR.
Collapse
Affiliation(s)
- Fan He
- School of Science, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
| | - Minru Li
- School of Science, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
| | - Xinyu Wang
- School of Science, Beijing University of Civil Engineering and Architecture, Beijing 100044, China
| | - Lu Hua
- Thrombosis Center, National Clinical Research Center for Cardiovascular Diseases, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| | - Tingting Guo
- Thrombosis Center, National Clinical Research Center for Cardiovascular Diseases, State Key Laboratory of Cardiovascular Disease, Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100037, China
| |
Collapse
|
19
|
Amabili M, Franchini G, Asgari M, Giovanniello F, Ghayesh MH, Breslavsky ID. Active and passive mechanical characterization of a human descending thoracic aorta with Klippel-Trenaunay syndrome. J Mech Behav Biomed Mater 2023; 148:106216. [PMID: 37924665 DOI: 10.1016/j.jmbbm.2023.106216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Accepted: 10/28/2023] [Indexed: 11/06/2023]
Abstract
A human aorta from a female donor affected by Klippel-Trenaunay syndrome was retrieved during a surgery for organ donation for transplant. The aorta was preserved in refrigerated Belzer UW organ preservation solution and tested within a few hours for mechanical characterization with and without vascular smooth muscle activation. KCl and Noradrenaline were used as vasoactive agents in bubbled Krebs-Henseleit buffer solution at 37 °C. A quasi-static and a dynamic mechanical characterization of the full wall and the three individual layers were carried out for strips taken in longitudinal and circumferential directions. The full wall in the descending portion of the aorta underwent mechanical tests with and without smooth muscle activation. Results were compared to data obtained from healthy aortas and show a reduced stiffness of the full wall in circumferential direction. Also, a significant reduction of the response to vasoactive agents in circumferential direction was observed, while the longitudinal response was similar to healthy cases.
Collapse
Affiliation(s)
- Marco Amabili
- Department of Mechanical Engineering, McGill University, Montreal, H3A 0C3, Canada.
| | - Giulio Franchini
- Advanced Material Research Center, Technology Innovation Institute, Abu Dhabi, United Arab Emirates
| | - Meisam Asgari
- Department of Medical Engineering, University of South Florida, Tampa, FL, USA
| | | | - Mergen H Ghayesh
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, Australia
| | - Ivan D Breslavsky
- Department of Mechanical Engineering, McGill University, Montreal, H3A 0C3, Canada
| |
Collapse
|
20
|
Giudici A, van der Laan KWF, van der Bruggen MM, Parikh S, Berends E, Foulquier S, Delhaas T, Reesink KD, Spronck B. Constituent-based quasi-linear viscoelasticity: a revised quasi-linear modelling framework to capture nonlinear viscoelasticity in arteries. Biomech Model Mechanobiol 2023; 22:1607-1623. [PMID: 37129690 PMCID: PMC10511394 DOI: 10.1007/s10237-023-01711-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Accepted: 03/08/2023] [Indexed: 05/03/2023]
Abstract
Arteries exhibit fully nonlinear viscoelastic behaviours (i.e. both elastically and viscously nonlinear). While elastically nonlinear arterial models are well established, effective mathematical descriptions of nonlinear viscoelasticity are lacking. Quasi-linear viscoelasticity (QLV) offers a convenient way to mathematically describe viscoelasticity, but its viscous linearity assumption is unsuitable for whole-wall vascular applications. Conversely, application of fully nonlinear viscoelastic models, involving deformation-dependent viscous parameters, to experimental data is impractical and often reduces to identifying specific solutions for each tested loading condition. The present study aims to address this limitation: By applying QLV theory at the wall constituent rather than at the whole-wall level, the deformation-dependent relative contribution of the constituents allows to capture nonlinear viscoelasticity with a unique set of deformation-independent model parameters. Five murine common carotid arteries were subjected to a protocol of quasi-static and harmonic, pseudo-physiological biaxial loading conditions to characterise their viscoelastic behaviour. The arterial wall was modelled as a constrained mixture of an isotropic elastin matrix and four families of collagen fibres. Constituent-based QLV was implemented by assigning different relaxation functions to collagen- and elastin-borne parts of the wall stress. Nonlinearity in viscoelasticity was assessed via the pressure dependency of the dynamic-to-quasi-static stiffness ratio. The experimentally measured ratio increased with pressure, from 1.03 [Formula: see text] 0.03 (mean [Formula: see text] standard deviation) at 80-40 mmHg to 1.58 [Formula: see text] 0.22 at 160-120 mmHg. Constituent-based QLV captured well this trend by attributing the wall viscosity predominantly to collagen fibres, whose recruitment starts at physiological pressures. In conclusion, constituent-based QLV offers a practical and effective solution to model arterial viscoelasticity.
Collapse
Affiliation(s)
- Alessandro Giudici
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Universiteitssingel 40, Room C5.568, 6229 ER, Maastricht, The Netherlands.
- GROW School for Oncology and Reproduction, Maastricht University, Maastricht, The Netherlands.
| | - Koen W F van der Laan
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Universiteitssingel 40, Room C5.568, 6229 ER, Maastricht, The Netherlands
| | - Myrthe M van der Bruggen
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Universiteitssingel 40, Room C5.568, 6229 ER, Maastricht, The Netherlands
| | - Shaiv Parikh
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Universiteitssingel 40, Room C5.568, 6229 ER, Maastricht, The Netherlands
| | - Eline Berends
- Department of Internal Medicine, CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
| | - Sébastien Foulquier
- Department of Pharmacology and Toxicology, CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands
| | - Tammo Delhaas
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Universiteitssingel 40, Room C5.568, 6229 ER, Maastricht, The Netherlands
| | - Koen D Reesink
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Universiteitssingel 40, Room C5.568, 6229 ER, Maastricht, The Netherlands
| | - Bart Spronck
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Universiteitssingel 40, Room C5.568, 6229 ER, Maastricht, The Netherlands
- Macquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, Australia
| |
Collapse
|
21
|
Takada J, Hamada K, Zhu X, Tsuboko Y, Iwasaki K. Biaxial tensile testing system for measuring mechanical properties of both sides of biological tissues. J Mech Behav Biomed Mater 2023; 146:106028. [PMID: 37531771 DOI: 10.1016/j.jmbbm.2023.106028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 07/11/2023] [Accepted: 07/14/2023] [Indexed: 08/04/2023]
Abstract
The aortic wall exhibits a unique elastic behavior, periodically expanding in aortic diameter by approximately 10% during heartbeats. This elastic behavior of the aortic wall relies on the distinct yet interacting mechanical properties of its three layers: intima, media, and adventitia. Aortic aneurysms develop as a result of multifactorial remodeling influenced by mechanical vulnerability of the aortic wall. Therefore, investigating the mechanical response of the aneurysmal wall, in conjunction with changes in microstructural parameters on both the intimal and adventitial sides, may offer valuable insights into the mechanisms of aortic aneurysm development or rupture. This study aimed to develop a biaxial tensile testing system to measure the mechanical properties of both sides of the tissue to gain insights concerning the interactions in anisotropic layered tissue. The biaxial tensile test set-up consisted of four motors, four cameras, four load cells, and a toggle switch. Porcine ascending aortas were chosen as the test subject. Graphite particles with diameters of approximately 5-11 [μm] were randomly applied to both sides of the aorta. Strain measurements were obtained using the stereo digital-image correlation method. Because stretching a rectangular specimen with a thread inevitably concentrates and localizes stress, to reduce this effect the specimen's shape was investigated using finite element analysis. The finite element analysis showed that a cross-shaped specimen with diagonally cut edges would be suitable. Therefore, we prepared specimens with this novel shape. This test system showed that mechanical response of the aortic tissue was significantly different between the intimal and adventitial side in the high-strain range, due to the disruption of collagen fibers. The adventitia side exhibited a smaller elastic modulus than the intimal side, accompanied by disruption of collagen fibers in the adventitia, which were more pronounced in the longitudinal direction. In contrast, in the mid-strain range, the elastic modulus did not differ between the intimal and adventitial sides, irrespective of longitudinal or circumferential direction, and collagen fibers were not disrupted but elongated. A biaxial tensile test system, which measures the mechanical properties of both sides of biological tissues and the shape of the specimen for reducing the concentration of stress at the chuck region, was developed in this study. The biaxial tensile testing system developed here is useful for better understanding the influences of mechanical loads and tissue degeneration on anisotropic, layered biological tissues.
Collapse
Affiliation(s)
- Jumpei Takada
- Department of Modern Mechanical Engineering, School of Creative Science and Engineering, Waseda University, Tokyo, Japan; Department of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan
| | - Kohei Hamada
- Department of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan
| | - Xiaodong Zhu
- Waseda Research Institute for Science and Engineering, Waseda University, Tokyo, Japan
| | - Yusuke Tsuboko
- Waseda Research Institute for Science and Engineering, Waseda University, Tokyo, Japan
| | - Kiyotaka Iwasaki
- Department of Modern Mechanical Engineering, School of Creative Science and Engineering, Waseda University, Tokyo, Japan; Department of Integrative Bioscience and Biomedical Engineering, Graduate School of Advanced Science and Engineering, Waseda University, Tokyo, Japan; Waseda Research Institute for Science and Engineering, Waseda University, Tokyo, Japan; Cooperative Major in Advanced Biomedical Sciences, Joint Graduate School of Tokyo Women's Medical University and Waseda University, Waseda University, Tokyo, Japan.
| |
Collapse
|
22
|
Kontomaris SV, Stylianou A, Chliveros G, Malamou A. A New Elementary Method for Determining the Tip Radius and Young's Modulus in AFM Spherical Indentations. MICROMACHINES 2023; 14:1716. [PMID: 37763878 PMCID: PMC10536531 DOI: 10.3390/mi14091716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2023] [Revised: 08/26/2023] [Accepted: 08/29/2023] [Indexed: 09/29/2023]
Abstract
Atomic force microscopy (AFM) is a powerful tool for characterizing biological materials at the nanoscale utilizing the AFM nanoindentation method. When testing biological materials, spherical indenters are typically employed to reduce the possibility of damaging the sample. The accuracy of determining Young's modulus depends, among other factors, on the calibration of the indenter, i.e., the determination of the tip radius. This paper demonstrates that the tip radius can be approximately calculated using a single force-indentation curve on an unknown, soft sample without performing any additional experimental calibration process. The proposed method is based on plotting a tangent line on the force indentation curve at the maximum indentation depth. Subsequently, using equations that relate the applied force, maximum indentation depth, and the tip radius, the calculation of the tip radius becomes trivial. It is significant to note that the method requires only a single force-indentation curve and does not necessitate knowledge of the sample's Young's modulus. Consequently, the determination of both the sample's Young's modulus and the tip radius can be performed simultaneously. Thus, the experimental effort is significantly reduced. The method was tested on 80 force-indentation curves obtained on an agarose gel, and the results were accurate.
Collapse
Affiliation(s)
- Stylianos Vasileios Kontomaris
- Faculty of Engineering and Architecture, Metropolitan College, 15125 Athens, Greece;
- BioNanoTec Ltd., Nicosia 2043, Cyprus
| | - Andreas Stylianou
- School of Sciences, European University Cyprus, Nicosia 2404, Cyprus;
| | - Georgios Chliveros
- Faculty of Engineering and Architecture, Metropolitan College, 15125 Athens, Greece;
| | - Anna Malamou
- Independent Power Transmission Operator S.A. (IPTO), 10443 Athens, Greece;
| |
Collapse
|
23
|
Wang X, Carpenter HJ, Ghayesh MH, Kotousov A, Zander AC, Amabili M, Psaltis PJ. A review on the biomechanical behaviour of the aorta. J Mech Behav Biomed Mater 2023; 144:105922. [PMID: 37320894 DOI: 10.1016/j.jmbbm.2023.105922] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 05/14/2023] [Accepted: 05/20/2023] [Indexed: 06/17/2023]
Abstract
Large aortic aneurysm and acute and chronic aortic dissection are pathologies of the aorta requiring surgery. Recent advances in medical intervention have improved patient outcomes; however, a clear understanding of the mechanisms leading to aortic failure and, hence, a better understanding of failure risk, is still missing. Biomechanical analysis of the aorta could provide insights into the development and progression of aortic abnormalities, giving clinicians a powerful tool in risk stratification. The complexity of the aortic system presents significant challenges for a biomechanical study and requires various approaches to analyse the aorta. To address this, here we present a holistic review of the biomechanical studies of the aorta by categorising articles into four broad approaches, namely theoretical, in vivo, experimental and combined investigations. Experimental studies that focus on identifying mechanical properties of the aortic tissue are also included. By reviewing the literature and discussing drawbacks, limitations and future challenges in each area, we hope to present a more complete picture of the state-of-the-art of aortic biomechanics to stimulate research on critical topics. Combining experimental modalities and computational approaches could lead to more comprehensive results in risk prediction for the aortic system.
Collapse
Affiliation(s)
- Xiaochen Wang
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, South Australia 5005, Australia.
| | - Harry J Carpenter
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Mergen H Ghayesh
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, South Australia 5005, Australia.
| | - Andrei Kotousov
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Anthony C Zander
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Marco Amabili
- Department of Mechanical Engineering, McGill University, Montreal H3A 0C3, Canada
| | - Peter J Psaltis
- Adelaide Medical School, The University of Adelaide, Adelaide, South Australia 5005, Australia; Department of Cardiology, Central Adelaide Local Health Network, Adelaide, South Australia 5000, Australia; Vascular Research Centre, Heart Health Theme, South Australian Health & Medical Research Institute (SAHMRI), Adelaide, South Australia 5000, Australia
| |
Collapse
|
24
|
Longtine AG, Venkatasubramanian R, Zigler MC, Lindquist AJ, Mahoney SA, Greenberg NT, VanDongen NS, Ludwig KR, Moreau KL, Seals DR, Clayton ZS. Female C57BL/6N mice are a viable model of aortic aging in women. Am J Physiol Heart Circ Physiol 2023; 324:H893-H904. [PMID: 37115626 PMCID: PMC10202480 DOI: 10.1152/ajpheart.00120.2023] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 04/20/2023] [Accepted: 04/21/2023] [Indexed: 04/29/2023]
Abstract
The aorta stiffens with aging in both men and women, which predicts cardiovascular mortality. Aortic wall structural and extracellular matrix (ECM) remodeling, induced in part by chronic low-grade inflammation, contribute to aortic stiffening. Male mice are an established model of aortic aging. However, there is little information regarding whether female mice are an appropriate model of aortic aging in women, which we aimed to elucidate in the present study. We assessed two strains of mice and found that in C57BL/6N mice, in vivo aortic stiffness (pulse wave velocity, PWV) was higher with aging in both sexes, whereas in B6D2F1 mice, PWV was higher in old versus young male mice, but not in old versus young female mice. Because the age-related stiffening that occurs in men and women was reflected in male and female C57BL/6N mice, we examined the mechanisms of stiffening in this strain. In both sexes, aortic modulus of elasticity (pin myography) was lower in old mice, occurred in conjunction with and was related to higher plasma levels of the elastin-degrading enzyme matrix metalloproteinase-9 (MMP-9), and was accompanied by higher numbers of aortic elastin breaks and higher abundance of adventitial collagen-1. Plasma levels of the inflammatory cytokines interferon-γ, interleukin 6, and monocyte chemoattractant protein-1 were higher in both sexes of old mice. In conclusion, female C57BL/6N mice exhibit aortic stiffening, reduced modulus of elasticity and structural/ECM remodeling, and associated increases in MMP-9 and systemic inflammation with aging, and thus are an appropriate model of aortic aging in women.NEW & NOTEWORTHY Our study demonstrates that with aging, female C57BL/6N mice exhibit higher in vivo aortic stiffness, reduced modulus of elasticity, aortic wall structural and extracellular matrix remodeling, and elevations in systemic inflammation. These changes are largely reflective of those that occur with aging in women. Thus, female C57BL/6N mice are a viable model of human aortic aging and the utility of these animals should be considered in future biomedical investigations.
Collapse
Affiliation(s)
- Abigail G Longtine
- Department of Integrative Physiology, University of Colorado Boulder, Boulder, Colorado, United States
| | | | - Melanie C Zigler
- Department of Integrative Physiology, University of Colorado Boulder, Boulder, Colorado, United States
| | - Alexandra J Lindquist
- Department of Integrative Physiology, University of Colorado Boulder, Boulder, Colorado, United States
| | - Sophia A Mahoney
- Department of Integrative Physiology, University of Colorado Boulder, Boulder, Colorado, United States
| | - Nathan T Greenberg
- Department of Integrative Physiology, University of Colorado Boulder, Boulder, Colorado, United States
| | - Nicholas S VanDongen
- Department of Integrative Physiology, University of Colorado Boulder, Boulder, Colorado, United States
| | - Katelyn R Ludwig
- Department of Integrative Physiology, University of Colorado Boulder, Boulder, Colorado, United States
| | - Kerrie L Moreau
- University of Colorado Anschutz Medical Campus, Aurora, Colorado, United States
| | - Douglas R Seals
- Department of Integrative Physiology, University of Colorado Boulder, Boulder, Colorado, United States
| | - Zachary S Clayton
- Department of Integrative Physiology, University of Colorado Boulder, Boulder, Colorado, United States
| |
Collapse
|
25
|
Pukaluk A, Wolinski H, Viertler C, Regitnig P, Holzapfel GA, Sommer G. Changes in the microstructure of the human aortic adventitia under biaxial loading investigated by multi-photon microscopy. Acta Biomater 2023; 161:154-169. [PMID: 36812954 DOI: 10.1016/j.actbio.2023.02.027] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 02/01/2023] [Accepted: 02/17/2023] [Indexed: 02/23/2023]
Abstract
Among the three layers of the aortic wall, the media is primarily responsible for its mechanical properties, but the adventitia prevents the aorta from overstretching and rupturing. The role of the adventitia is therefore crucial with regard to aortic wall failure, and understanding the load-induced changes in tissue microstructure is of high importance. Specifically, the focus of this study is on the changes in collagen and elastin microstructure in response to macroscopic equibiaxial loading applied to the aortic adventitia. To observe these changes, multi-photon microscopy imaging and biaxial extension tests were performed simultaneously. In particular, microscopy images were recorded at 0.02 stretch intervals. The microstructural changes of collagen fiber bundles and elastin fibers were quantified with the parameters of orientation, dispersion, diameter, and waviness. The results showed that the adventitial collagen was divided from one into two fiber families under equibiaxial loading conditions. The almost diagonal orientation of the adventitial collagen fiber bundles remained unchanged, but the dispersion was substantially reduced. No clear orientation of the adventitial elastin fibers was observed at any stretch level. The waviness of the adventitial collagen fiber bundles decreased under stretch, but the adventitial elastin fibers showed no change. These original findings highlight differences between the medial and adventitial layers and provide insight into the stretching process of the aortic wall. STATEMENT OF SIGNIFICANCE: To provide accurate and reliable material models, it is essential to understand the mechanical behavior of the material and its microstructure. Such understanding can be enhanced with tracking of the microstructural changes caused by mechanical loading of the tissue. This study provides therefore a unique dataset of structural parameters of the human aortic adventitia obtained under equibiaxial loading. The structural parameters describe orientation, dispersion, diameter, and waviness of collagen fiber bundles and elastin fibers. Eventually, the microstructural changes in the human aortic adventitia are compared with the microstructural changes in the human aortic media from a previous study. This comparison reveals the cutting-edge findings on the differences in the response to the loading between these two human aortic layers.
Collapse
Affiliation(s)
- Anna Pukaluk
- Institute of Biomechanics, Graz University of Technology, Austria
| | - Heimo Wolinski
- Institute of Molecular Biosciences, University of Graz, Austria; Field of Excellence BioHealth, University of Graz, Austria
| | - Christian Viertler
- Diagnostic and Research Institute of Pathology, Medical University of Graz, Austria
| | - Peter Regitnig
- Diagnostic and Research Institute of Pathology, Medical University of Graz, Austria
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Austria; Department of Structural Engineering (NTNU), Trondheim, Norway
| | - Gerhard Sommer
- Institute of Biomechanics, Graz University of Technology, Austria.
| |
Collapse
|
26
|
Wang R, Mattson JM, Zhang Y. Effect of aging on the biaxial mechanical behavior of human descending thoracic aorta: Experiments and constitutive modeling considering collagen crosslinking. J Mech Behav Biomed Mater 2023; 140:105705. [PMID: 36758423 PMCID: PMC10023391 DOI: 10.1016/j.jmbbm.2023.105705] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Revised: 01/20/2023] [Accepted: 02/01/2023] [Indexed: 02/05/2023]
Abstract
Collagen crosslinking, an important contributor to the stiffness of soft tissues, was found to increase with aging in the aortic wall. Here we investigated the mechanical properties of human descending thoracic aorta with aging and the role of collagen crosslinking through a combined experimental and modeling approach. A total of 32 samples from 17 donors were collected and divided into three age groups: <40, 40-60 and > 60 years. Planar biaxial tensile tests were performed to characterize the anisotropic mechanical behavior of the aortic samples. A recently developed constitutive model incorporating collagen crosslinking into the two-fiber family model (Holzapfel and Ogden, 2020) was modified to accommodate biaxial deformation of the aorta, in which the extension and rotation kinematics of bonded fibers and crosslinks were decoupled. The mechanical testing results show that the aorta stiffens with aging with a more drastic change in the longitudinal direction, which results in altered aortic anisotropy. Our results demonstrate a good fitting capability of the constitutive model considering crosslinking for the biaxial aortic mechanics of all age groups. Furthermore, constitutive modeling results suggest an increased contribution of crosslinking and strain energy density to the biaxial stress-stretch behaviors with aging and point to excessive crosslinking as a prominent contributor to aortic stiffening.
Collapse
Affiliation(s)
- Ruizhi Wang
- Department of Mechanical Engineering, Boston University, Boston, MA, 02215, USA
| | - Jeffrey M Mattson
- Department of Mechanical Engineering, Boston University, Boston, MA, 02215, USA
| | - Yanhang Zhang
- Department of Mechanical Engineering, Boston University, Boston, MA, 02215, USA; Department of Biomedical Engineering, Boston University, Boston, MA, 02215, USA; Divison of Materials Science & Engineering, Boston University, Boston, MA, 02215, USA.
| |
Collapse
|
27
|
Giovanniello F, Asgari M, Breslavsky ID, Franchini G, Holzapfel GA, Tabrizian M, Amabili M. Development and mechanical characterization of decellularized scaffolds for an active aortic graft. Acta Biomater 2023; 160:59-72. [PMID: 36792047 DOI: 10.1016/j.actbio.2023.02.013] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 02/02/2023] [Accepted: 02/07/2023] [Indexed: 02/16/2023]
Abstract
Decellularized porcine aortas are proposed as scaffolds for revolutionary active aortic grafts. A change in the static and dynamic mechanical properties, associated with the microstructure of elastin and collagen fibers, corresponds to alteration in the cyclic expansion and perfusion, in addition to possible graft damage. Therefore, the present study thoroughly investigates the mechanical response of the decellularized scaffolds of human and porcine origin to static and dynamic mechanical loads. The responses of the native human and porcine aortas are also compared; this is unavailable in the literature. Because the aorta is subjected to pulsatile blood pressure, dynamical responses to cyclic loads and their associated viscoelastic properties are particularly relevant for advanced graft design. In parallel, this study examines the microstructure of the decellularized aorta. The resulting data are compared to the analogous data obtained for the native human and porcine tissues. The results indicate that by using an optimized decellularization protocol - based on sodium dodecyl sulfate (SDS) and DNase - that minimizes mechanical and structural changes of the tissue, layered scaffolds with static and dynamic properties very similar to natural human aortas are obtained. In particular, a decellularized porcine aorta is non-inferior to a decellularized human aorta. STATEMENT OF SIGNIFICANCE: About 55,000 patients undergo abdominal aortic aneurysm repair annually in the USA. The currently implanted grafts present a large mechanical mismatch with the native tissue. This increases the pulsatile nature of the blood flow with negative consequences to the organ perfusion. For this reason, biomimetic and mechanically compatible grafts for aortic repair are urgently needed and they can be obtained through tissue engineering. In this study, scaffolds from porcine and human aortas are obtained from an optimized decellularization protocol. They are accurately compared to the native tissue and present the ideal static and dynamic mechanical properties for developing innovative aortic grafts.
Collapse
Affiliation(s)
| | - Meisam Asgari
- Department of Mechanical Engineering, McGill University, Montreal, Canada
| | - Ivan D Breslavsky
- Department of Mechanical Engineering, McGill University, Montreal, Canada
| | - Giulio Franchini
- Department of Mechanical Engineering, McGill University, Montreal, Canada
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Austria; Department of Structural Engineering, Norwegian University of Science and Technology, Trondheim, Norway
| | - Maryam Tabrizian
- Department of Biomedical Engineering, McGill University, Montreal, Canada; Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal, Canada
| | - Marco Amabili
- Department of Mechanical Engineering, McGill University, Montreal, Canada; Advanced Materials Research Center, Technology Innovation Institute (TII), Abu Dhabi, UAE.
| |
Collapse
|
28
|
Dwivedi KK, Lakhani P, Yadav A, Kumar S, Kumar N. Location specific multi-scale characterization and constitutive modeling of pig aorta. J Mech Behav Biomed Mater 2023; 142:105809. [PMID: 37116311 DOI: 10.1016/j.jmbbm.2023.105809] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 03/18/2023] [Accepted: 03/25/2023] [Indexed: 04/03/2023]
Abstract
The mechanical and structural behavior of the aorta depend on physiological functions and vary from proximal to distal. Understanding the relation between regionally varying mechanical and multi-scale structural response of aorta can be helpful to assess the disease outcomes. Therefore, this study investigated the variation in mechanical and multi-scale structural properties among the major segments of aorta such as ascending aorta (AA), descending aorta (DA) and abdominal aorta (ABA), and established a relation between mechanical and multi-structural parameters. The obtained results showed significant increase in anisotropy and nonlinearity from proximal to distal aorta. The change in periphery length and radii between load and stress free configuration was also found increasing far from the heart. Opening angle was significantly large for ABA than AA and DA (AA/DA vs ABA; p = 0.001). Mean circumferential residual stretch (ratio of mean periphery length at load and stress free configurations) was found decreasing between AA and DA, and then increasing between DA to ABA and its value was significantly more for ABA (AA vs DA; p = 0.041, AA vs ABA; p = 0.001, DA vs ABA; p = 0.001). The waviness of collagen fibers, collagen fiber content, collagen fibril diameter and total protein content were found significantly increasing from proximal to distal. Pearson correlation test showed a significant linear correlation between variation in mechanical and multi-scale structural parameters over the aortic length. Residual stretch was found positively correlated with collagen fiber content (r = 0.82) whereas opening angel was found positively correlated with total protein content (TPC) (r = 0.76).
Collapse
Affiliation(s)
| | | | - Ashu Yadav
- Department of Automobile Engineering, Manipal University Jaipur, Jaipur, India
| | - Sachin Kumar
- Department of Mechanical Engineering, IIT Ropar, India.
| | - Navin Kumar
- Department of Biomedical Engineering, IIT Ropar, India; Department of Mechanical Engineering, IIT Ropar, India.
| |
Collapse
|
29
|
Breslavsky ID, Amabili M. Fitting mechanical properties of the aortic wall and individual layers to experimental tensile tests including residual stresses. J Mech Behav Biomed Mater 2023; 138:105647. [PMID: 36610281 DOI: 10.1016/j.jmbbm.2022.105647] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 12/27/2022] [Accepted: 12/29/2022] [Indexed: 12/31/2022]
Abstract
The authors have observed that a stress-strain curve for uniaxial tension of an aortic intact wall cannot be simply obtained by combining the strain energy functions of the three individual aortic layers - intima, media and adventitia - even taking into account the interaction among the three layers; the strain energy functions of the three layers are obtained fitting tensile tests on strips from the individual layers. Due to the layer separation, the residual stresses are released and thus they do not affect the stress-strain curves of the individual layers. The present study shows that it is instead possible to fit the intact wall experimental curves with the combination of the strain energy functions of the three individual layers if residual strains are added. The residual strains are used as optimization parameters with specific constraints and allowing for the buckling (wrinkling) of the intima under unpressurized condition of the aortic wall, as experimentally observed. By varying these parameters in the experimentally observed range of values, it is possible to find a solution with the combined responses of the individual layers matching the experimental stress-strain curves of the intact wall.
Collapse
Affiliation(s)
- Ivan D Breslavsky
- Department of Mechanical Engineering, McGill University, Montreal, PQ, Canada
| | - Marco Amabili
- Department of Mechanical Engineering, McGill University, Montreal, PQ, Canada.
| |
Collapse
|
30
|
Guo T, Wantono C, Tan Y, Deng F, Duan T, Liu D. Regulators, functions, and mechanotransduction pathways of matrix stiffness in hepatic disease. Front Physiol 2023; 14:1098129. [PMID: 36711017 PMCID: PMC9878334 DOI: 10.3389/fphys.2023.1098129] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Accepted: 01/06/2023] [Indexed: 01/15/2023] Open
Abstract
The extracellular matrix (ECM) provides physical support and imparts significant biochemical and mechanical cues to cells. Matrix stiffening is a hallmark of liver fibrosis and is associated with many hepatic diseases, especially liver cirrhosis and carcinoma. Increased matrix stiffness is not only a consequence of liver fibrosis but is also recognized as an active driver in the progression of fibrotic hepatic disease. In this article, we provide a comprehensive view of the role of matrix stiffness in the pathological progression of hepatic disease. The regulators that modulate matrix stiffness including ECM components, MMPs, and crosslinking modifications are discussed. The latest advances of the research on the matrix mechanics in regulating intercellular signaling and cell phenotype are classified, especially for hepatic stellate cells, hepatocytes, and immunocytes. The molecular mechanism that sensing and transducing mechanical signaling is highlighted. The current progress of ECM stiffness's role in hepatic cirrhosis and liver cancer is introduced and summarized. Finally, the recent trials targeting ECM stiffness for the treatment of liver disease are detailed.
Collapse
Affiliation(s)
- Ting Guo
- Department of Gastroenterology, The Second Xiangya Hospital of Central South University, Changsha, China
- Research Center of Digestive Disease, Central South University, Changsha, China
| | - Cindy Wantono
- Department of Gastroenterology, The Second Xiangya Hospital of Central South University, Changsha, China
- Research Center of Digestive Disease, Central South University, Changsha, China
| | - Yuyong Tan
- Department of Gastroenterology, The Second Xiangya Hospital of Central South University, Changsha, China
- Research Center of Digestive Disease, Central South University, Changsha, China
| | - Feihong Deng
- Department of Gastroenterology, The Second Xiangya Hospital of Central South University, Changsha, China
- Research Center of Digestive Disease, Central South University, Changsha, China
| | - Tianying Duan
- Department of Gastroenterology, The Second Xiangya Hospital of Central South University, Changsha, China
- Research Center of Digestive Disease, Central South University, Changsha, China
| | - Deliang Liu
- Department of Gastroenterology, The Second Xiangya Hospital of Central South University, Changsha, China
- Research Center of Digestive Disease, Central South University, Changsha, China
| |
Collapse
|
31
|
Kontomaris SV, Stylianou A, Chliveros G, Malamou A. Determining Spatial Variability of Elastic Properties for Biological Samples Using AFM. MICROMACHINES 2023; 14:mi14010182. [PMID: 36677243 PMCID: PMC9862197 DOI: 10.3390/mi14010182] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 12/26/2022] [Accepted: 01/09/2023] [Indexed: 05/29/2023]
Abstract
Measuring the mechanical properties (i.e., elasticity in terms of Young's modulus) of biological samples using Atomic Force Microscopy (AFM) indentation at the nanoscale has opened new horizons in studying and detecting various pathological conditions at early stages, including cancer and osteoarthritis. It is expected that AFM techniques will play a key role in the future in disease diagnosis and modeling using rigorous mathematical criteria (i.e., automated user-independent diagnosis). In this review, AFM techniques and mathematical models for determining the spatial variability of elastic properties of biological materials at the nanoscale are presented and discussed. Significant issues concerning the rationality of the elastic half-space assumption, the possibility of monitoring the depth-dependent mechanical properties, and the construction of 3D Young's modulus maps are also presented.
Collapse
Affiliation(s)
- Stylianos Vasileios Kontomaris
- BioNanoTec Ltd., Nicosia 2043, Cyprus
- Faculty of Engineering and Architecture, Metropolitan College, 15125 Athens, Greece
| | - Andreas Stylianou
- School of Sciences, European University Cyprus, Nicosia 2404, Cyprus
| | - Georgios Chliveros
- Faculty of Engineering and Architecture, Metropolitan College, 15125 Athens, Greece
| | - Anna Malamou
- School of Electrical and Computer Engineering, National Technical University of Athens, 15780 Athens, Greece
| |
Collapse
|
32
|
Pukaluk A, Wolinski H, Viertler C, Regitnig P, Holzapfel GA, Sommer G. Changes in the microstructure of the human aortic medial layer under biaxial loading investigated by multi-photon microscopy. Acta Biomater 2022; 151:396-413. [PMID: 35970481 DOI: 10.1016/j.actbio.2022.08.017] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2022] [Revised: 07/29/2022] [Accepted: 08/08/2022] [Indexed: 11/01/2022]
Abstract
Understanding the correlation between tissue architecture, health status, and mechanical properties is essential for improving material models and developing tissue engineering scaffolds. Since structural-based material models are state of the art, there is an urgent need for experimentally obtained structural parameters. For this purpose, the medial layer of nine human abdominal aortas was simultaneously subjected to equibiaxial loading and multi-photon microscopy. At each loading interval of 0.02, collagen and elastin fibers were imaged based on their second-harmonic generation signal and two-photon excited autofluorescence, respectively. The structural alterations in the fibers were quantified using the parameters of orientation, diameter, and waviness. The results of the mechanical tests divided the sample cohort into the ruptured and non-ruptured, and stiff and non-stiff groups, which were covered by the findings from histological investigations. The alterations in structural parameters provided an explanation for the observed mechanical behavior. In addition, the waviness parameters of both collagen and elastin fibers showed the potential to serve as indicators of tissue strength. The data provided address deficiencies in current material models and bridge multiscale mechanisms in the aortic media. STATEMENT OF SIGNIFICANCE: Available material models can reproduce, but cannot predict, the mechanical behavior of human aortas. This deficiency could be overcome with the help of experimentally validated structural parameters as provided in this study. Simultaneous multi-photon microscopy and biaxial extension testing revealed the microstructure of human aortic media at different stretch levels. Changes in the arrangement of collagen and elastin fibers were quantified using structural parameters such as orientation, diameter and waviness. For the first time, structural parameters of human aortic tissue under continuous loading conditions have been obtained. In particular, the waviness parameters at the reference configuration have been associated with tissue stiffness, brittleness, and the onset of atherosclerosis.
Collapse
Affiliation(s)
- Anna Pukaluk
- Institute of Biomechanics, Graz University of Technology, Austria
| | - Heimo Wolinski
- Institute of Molecular Biosciences, University of Graz, Austria; Field of Excellence BioHealth - University of Graz, Austria
| | | | - Peter Regitnig
- Institute of Pathology, Medical University of Graz, Austria
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Austria; Department of Structural Engineering, NTNU, Trondheim, Norway
| | - Gerhard Sommer
- Institute of Biomechanics, Graz University of Technology, Austria.
| |
Collapse
|
33
|
De Moudt S, Hendrickx JO, De Meyer GRY, Martinet W, Fransen P. Disparate biomechanical properties of the aorta in non-aneurysmal and aneurysmal mice treated with angiotensin II. Physiol Rep 2022; 10:e15410. [PMID: 36117398 PMCID: PMC9483617 DOI: 10.14814/phy2.15410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 07/08/2022] [Accepted: 07/14/2022] [Indexed: 06/15/2023] Open
Abstract
In vivo angiotensin II (AngII)-treatment is a widely used experimental model to induce cardiovascular disease and results in a high likelihood of abdominal aorta aneurysm (AAA) formation. This involves progressive and irreversible focal dilation of the abdominal aorta and induces adverse aortic connective tissue remodeling contributing to aortic wall stiffening through inflammation, elastin degradation, and collagen restructuring. Hence, the present study aimed to investigate how AAA formation in AngII-treated mice affects aortic function and biomechanics. To this end, C57Bl/6J mice were treated with AngII (1000 ng/[kg.min]) or PBS infusion for 28 days. Peripheral blood pressure, echocardiography, and aortic pulse wave velocity were measured in vivo. Thoracic aorta rings were studied ex vivo in organ chambers, while aortic vascular smooth muscle cell (VSMC) phenotype was investigated histologically. We confirmed peripheral hypertension, cardiac hypertrophy, aortic stiffening, and increased VSMC proliferation and migration after AngII-treatment. Abdominal aorta aneurysm formation was observed in 8/13 AngII-treated mice. Ex vivo thoracic aortic rings of both aneurysmal and non-aneurysmal AngII-treated mice showed high isobaric aortic stiffness, endothelial dysfunction, heightened α1 -adrenergic contractility, and altered VSMC contractile calcium signaling. However, aortic biomechanics were differently affected, with heightened α1 -adrenoreceptor mediated aortic stiffening in non-aneurysmal mice, whereas contraction-dependent stiffening was impaired in aneurysmal mice. In conclusion, although aneurysmal and non-aneurysmal 4-week AngII-treated mice displayed similar changes in aortic physiology, aortic biomechanics were dissimilarly affected.
Collapse
Affiliation(s)
- Sofie De Moudt
- Laboratory of PhysiopharmacologyUniversity of AntwerpAntwerpBelgium
| | | | | | - Wim Martinet
- Laboratory of PhysiopharmacologyUniversity of AntwerpAntwerpBelgium
| | - Paul Fransen
- Laboratory of PhysiopharmacologyUniversity of AntwerpAntwerpBelgium
| |
Collapse
|
34
|
Li Z, Luo T, Wang S, Jia H, Gong Q, Liu X, Sutcliffe MPF, Zhu H, Liu Q, Chen D, Xiong J, Teng Z. Mechanical and histological characteristics of aortic dissection tissues. Acta Biomater 2022; 146:284-294. [PMID: 35367380 DOI: 10.1016/j.actbio.2022.03.042] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 03/23/2022] [Accepted: 03/24/2022] [Indexed: 12/14/2022]
Abstract
AIMS This study investigated the association between the macroscopic mechanical response of aortic dissection (AoD) flap, its fibre features, and patient physiological features and clinical presentations. METHODS Uniaxial test was performed with tissue strips in both circumferential and longitudinal directions from 35 patients with (AoD:CC) and without (AoD:w/oCC) cerebral/coronary complications, and 19 patients with rheumatic or valve-related heart diseases (RH). A Bayesian inference framework was used to estimate the expectation of material constants (C1, D1, and D2) of the modified Mooney-Rivlin strain energy density function. Histological examination was used to visualise the elastin and collagen in the tissue strips and image processing was performed to quantify their area percentages, fibre misalignment and waviness. RESULTS The elastin area percentage was negatively associated with age (p = 0.008), while collagen increased about 6% from age 40 to 70 (p = 0.03). Elastin fibre was less dispersed and wavier in old patients and no significant association was found between patient age and collagen fibre dispersion or waviness. Features of fibrous microstructures, either elastin or collagen, were comparable between AoD:CC and AoD:w/oCC group. Elastin and collagen area percentages were positively correlated with C1 and D2, respectively, while the elastin and collagen waviness were negatively correlated with C1 and D2, respectively. Elastin dispersion was negatively correlated to D2. Multivariate analysis showed that D2 was an effective parameter which could differentiate patient groups with different age and clinical presentations, as well as the direction of tissue strip. CONCLUSION Fibre dispersion and waviness in the aortic dissection flap changed with patient age and clinical presentations, and these can be captured by the material constants in the strain energy density function. STATEMENT OF SIGNIFICANCE Aortic dissection (AoD) is a severe cardiovascular disease. Understanding the mechanical property of intimal flap is essential for its risk evaluation. In this study, mechanical testing and histology examination were combined to quantify the relationship between mechanical presentations and microstructure features. A Bayesian inference framework was employed to estimate the expectation of the material constants in the modified Mooney-Rivlin constitutive equation. It was found that fibre dispersion and waviness in the AoD flap changed with patient age and clinical presentations, and these could be captured by the material constants. This study firstly demonstrated that the expectation of material constants can be used to characterise tissue microstructures and differentiate patients with different clinical presentations.
Collapse
|
35
|
Horný L, Roubalová L, Kronek J, Chlup H, Adámek T, Blanková A, Petřivý Z, Suchý T, Tichý P. Correlation between age, location, orientation, loading velocity and delamination strength in the human aorta. J Mech Behav Biomed Mater 2022; 133:105340. [PMID: 35785636 DOI: 10.1016/j.jmbbm.2022.105340] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Revised: 06/10/2022] [Accepted: 06/25/2022] [Indexed: 11/15/2022]
Abstract
Aortic dissection is a biomechanical phenomenon associated with a failure of internal cohesion, which manifests itself through the delamination of the aortic wall. The goal of this study is to deepen our knowledge of the delamination strength of the aorta. To achieve this, 661 peeling experiments were carried out with strips of the human aorta collected from 46 cadavers. The samples were ordered into groups with respect to (1) anatomical location, (2) orientation of the sample, and (3) extension rate used within the experiment. The obtained results are in accordance with the hypothesis that delamination resistance is not sensitive to the extension rates 0.1, 1, 10, and 50 mms-1. We arrived at this conclusion for all positions along the aorta investigated in our study. These were the thoracic ascending (AAs), thoracic descending (ADs), and the abdominal aorta (AAb), simultaneously considering both the longitudinal (L) as well as the circumferential (C) orientations of the samples. On the other hand, our results showed that the delamination strength differs significantly with respect to the anatomical position and orientation of the sample. The medians of the delamination strength were as follows, 4.1 in AAs-L, 3.2 in AAs-C, 3.1 in ADs-L, 2.4 in ADs-C, AAb-L in 3.6, and 2.7 in AAb-C case (all values are in 0.01·Nmm-1). This suggests that resistance to crack propagation should be an anisotropic property and that the aorta is inhomogeneous along its length from the point of view of delamination resistance. Finally, correlation analysis proved that the delamination strength of the human aorta significantly decreases with age.
Collapse
Affiliation(s)
- Lukáš Horný
- Czech Technical University in Prague, Faculty of Mechanical Engineering, Technická 4, 160 00, Prague, Czech Republic.
| | - Lucie Roubalová
- Czech Technical University in Prague, Faculty of Mechanical Engineering, Technická 4, 160 00, Prague, Czech Republic
| | - Jakub Kronek
- Czech Technical University in Prague, Faculty of Mechanical Engineering, Technická 4, 160 00, Prague, Czech Republic
| | - Hynek Chlup
- Czech Technical University in Prague, Faculty of Mechanical Engineering, Technická 4, 160 00, Prague, Czech Republic
| | - Tomáš Adámek
- Regional Hospital Liberec, Department of Forensic Medicine and Toxicology, Husova 357/10, 460 63, Liberec, Czech Republic
| | - Alžběta Blanková
- Regional Hospital Liberec, Department of Forensic Medicine and Toxicology, Husova 357/10, 460 63, Liberec, Czech Republic
| | - Zdeněk Petřivý
- Czech Technical University in Prague, Faculty of Mechanical Engineering, Technická 4, 160 00, Prague, Czech Republic
| | - Tomáš Suchý
- Czech Technical University in Prague, Faculty of Mechanical Engineering, Technická 4, 160 00, Prague, Czech Republic; Institute of Rock Structure and Mechanics of The Czech Academy of Sciences, V Holešovičkách 94/41, 182 09, Prague, Czech Republic
| | - Petr Tichý
- Czech Technical University in Prague, Faculty of Mechanical Engineering, Technická 4, 160 00, Prague, Czech Republic
| |
Collapse
|
36
|
Linka K, Cavinato C, Humphrey JD, Cyron CJ. Predicting and understanding arterial elasticity from key microstructural features by bidirectional deep learning. Acta Biomater 2022; 147:63-72. [PMID: 35643194 DOI: 10.1016/j.actbio.2022.05.039] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 05/19/2022] [Accepted: 05/19/2022] [Indexed: 01/15/2023]
Abstract
Microstructural features and mechanical properties are closely related in all soft biological tissues. Both yet exhibit considerable inter-individual differences and are affected by factors such as aging and disease and its progression. Histological analysis, modern in situ imaging, and biomechanical testing have deepened our understanding of these complex interrelations, yet two key questions remain: (1) Given the specific microstructure, can one predict the macroscopic mechanical properties without mechanical testing? (2) Can one quantify individual contributions of the different microstructural features to the macroscopic mechanical properties in an automated, systematic and largely unbiased way? Here we propose a bidirectional deep learning architecture to address these two questions. Our architecture uses data from standard histological analyses, two-photon microscopy and biaxial biomechanical testing. Its capabilities are demonstrated by predicting with high accuracy (R2=0.92) the evolving mechanical properties of the murine aorta during maturation and aging. Moreover, our architecture reveals that the extracellular matrix composition and organization are the most prominent factors governing the macroscopic mechanical properties of the tissues studied herein. STATEMENT OF SIGNIFICANCE: .
Collapse
Affiliation(s)
- Kevin Linka
- Institute for Continuum and Material Mechanics, Hamburg University of Technology, Hamburg, Germany
| | - Cristina Cavinato
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA
| | - Jay D Humphrey
- Department of Biomedical Engineering, Yale University, New Haven, CT, USA; Vascular Biology and Therapeutics Program, Yale School of Medicine, New Haven, CT, USA
| | - Christian J Cyron
- Institute for Continuum and Material Mechanics, Hamburg University of Technology, Hamburg, Germany; Institute of Material Systems Modeling, Helmholtz-Zentrum Hereon, Geesthacht, Germany.
| |
Collapse
|
37
|
Niestrawska JA, Pukaluk A, Babu AR, Holzapfel GA. Differences in Collagen Fiber Diameter and Waviness between Healthy and Aneurysmal Abdominal Aortas. MICROSCOPY AND MICROANALYSIS : THE OFFICIAL JOURNAL OF MICROSCOPY SOCIETY OF AMERICA, MICROBEAM ANALYSIS SOCIETY, MICROSCOPICAL SOCIETY OF CANADA 2022; 28:1-15. [PMID: 35545876 DOI: 10.1017/s1431927622000629] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Collagen plays a key role in the strength of aortic walls, so studying micro-structural changes during disease development is critical to better understand collagen reorganization. Second-harmonic generation microscopy is used to obtain images of human aortic collagen in both healthy and diseased states. Methods are being developed in order to efficiently determine the waviness, that is, tortuosity and amplitude, as well as the diameter, orientation, and dispersion of collagen fibers, and bundles in healthy and aneurysmal tissues. The results show layer-specific differences in the collagen of healthy tissues, which decrease in samples of aneurysmal aortic walls. In healthy tissues, the thick collagen bundles of the adventitia are characterized by greater waviness, both in the tortuosity and in the amplitude, compared to the relatively thin and straighter collagen fibers of the media. In contrast, most aneurysmal tissues tend to have a more uniform structure of the aortic wall with no significant difference in collagen diameter between the luminal and abluminal layers. An increase in collagen tortuosity compared to the healthy media is also observed in the aneurysmal luminal layer. The data set provided can help improve related material and multiscale models of aortic walls and aneurysm formation.
Collapse
Affiliation(s)
- Justyna A Niestrawska
- Institute of Biomechanics, Graz University of Technology, Stremayrgasse 16, 8010Graz, Austria
| | - Anna Pukaluk
- Institute of Biomechanics, Graz University of Technology, Stremayrgasse 16, 8010Graz, Austria
| | - Anju R Babu
- Institute of Biomechanics, Graz University of Technology, Stremayrgasse 16, 8010Graz, Austria
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Stremayrgasse 16, 8010Graz, Austria
- Department of Structural Engineering, Norwegian University of Science and Technology (NTNU), 7491Trondheim, Norway
| |
Collapse
|
38
|
Viscoelasticity of human descending thoracic aorta in a mock circulatory loop. J Mech Behav Biomed Mater 2022; 130:105205. [PMID: 35390678 DOI: 10.1016/j.jmbbm.2022.105205] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2022] [Revised: 02/26/2022] [Accepted: 03/26/2022] [Indexed: 12/11/2022]
Abstract
Healthy human descending thoracic aortas, obtained during organ donation for transplant and research, were tested in a mock circulatory loop to measure the mechanical response to physiological pulsatile pressure and flow. The viscoelastic properties of the aortic segments were investigated at three different pulse rates. The same aortic segments were also subjected to quasi-static pressure tests in order to identify the aortic dynamic stiffness ratio, which is defined as the ratio between the stiffness in case of pulsatile pressure and the stiffness measured for static pressurization, both at the same value of pressure. The loss factor was also identified. The shape of the deformed aorta under static and dynamic pressure was measured by image processing to verify the compatibility of the end supports with the natural deformation of the aorta in the human body. In addition, layer-specific experiments on 10 human descending thoracic aortas allowed to precisely identify the mass density of the aortic tissue, which is an important parameter in cardiovascular dynamic models.
Collapse
|
39
|
Zhang W, Sommer G, Niestrawska JA, Holzapfel GA, Nordsletten D. The effects of viscoelasticity on residual strain in aortic soft tissues. Acta Biomater 2022; 140:398-411. [PMID: 34823042 DOI: 10.1016/j.actbio.2021.11.019] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 11/14/2021] [Accepted: 11/15/2021] [Indexed: 11/15/2022]
Abstract
Residual stress is thought to play a critical role in modulating stress distributions in soft biological tissues and in maintaining the mechanobiological stress environment of cells. Residual stresses in arteries and other tissues are classically assessed through opening angle experiments, which demonstrate the continuous release of residual stresses over hours. These results are then assessed through nonlinear biomechanical models to provide estimates of the residual stresses in the intact state. Although well studied, these analyses typically focus on hyperelastic material models despite significant evidence of viscoelastic phenomena over both short and long timescales. In this work, we extended the state-of-the-art structural tensor model for arterial tissues from Holzapfel and Ogden for fractional viscoelasticity. Models were tuned to capture consistent levels of hysteresis observed in biaxial experiments, while also minimizing the fractional viscoelastic weighting and opening angles to correctly capture opening angle dynamics. Results suggest that a substantial portion of the human abdominal aorta is viscoelastic, but exhibits a low fractional order (i.e. more elastically). Additionally, a significantly larger opening angle in the fully unloaded state is necessary to produce comparable hysteresis in biaxial testing. As a consequence, conventional estimates of residual stress using hyperelastic approaches over-estimate their viscoelastic counterparts by a factor of 2. Thus, a viscoelastic approach, such as the one illustrated in this study, in combination with an additional source of rate-controlled viscoelastic data is necessary to accurately analyze the residual stress distribution in soft biological tissues. STATEMENT OF SIGNIFICANCE: Residual stress plays a crucial role in achieving a homeostatic stress environment in soft biological tissues. However, the analysis of residual stress typically focuses on hyperelastic material models despite evidence of viscoelastic behavior. This work is the first attempt at analyzing the effects of viscoelasticity on residual stress. The application of viscoelasticity was crucial for producing realistic opening dynamics in arteries. The overall residual stresses were estimated to be 50% less than those from using hyperelastic material models, while the opening angles were projected to be 25% more than those measured after 16 hours, suggesting underestimated residual strain. This study highlights the importance viscoelasticity in the analysis of residual stress even in weakly dissipative materials like the human aorta.
Collapse
Affiliation(s)
- Will Zhang
- Department of Biomedical Engineering, University of Michigan, North Campus Research Center, Building 20, 2800 Plymouth Rd, Ann Arbor 48109, USA.
| | - Gerhard Sommer
- Institute of Biomechanics, Graz University of Technology, AT, Austria
| | - Justyna A Niestrawska
- Gottfried Schatz Research Center, Division of Macroscopic and Clinical Anatomy, Medical University of Graz, Harrachgasse 21, 8010 Graz, Austria
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, AT, Austria; Department of Structural Engineering, Norwegian University of Science and Technology, Trondheim, NO, Norway
| | - David Nordsletten
- Division of Biomedical Engineering and Imaging Sciences, Department of Biomedical Engineering, King's College London, UK; Departments of Biomedical Engineering and Cardiac Surgery, University of Michigan, Ann Arbor, USA
| |
Collapse
|
40
|
Asgari M, Latifi N, Giovanniello F, Espinosa HD, Amabili M. Revealing Layer‐Specific Ultrastructure and Nanomechanics of Fibrillar Collagen in Human Aorta via Atomic Force Microscopy Testing: Implications on Tissue Mechanics at Macroscopic Scale. ADVANCED NANOBIOMED RESEARCH 2022. [DOI: 10.1002/anbr.202100159] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Affiliation(s)
- Meisam Asgari
- Department of Mechanical Engineering McGill University 817 Sherbrooke Street West Montreal QC H3A 0C3 Canada
- Theoretical and Applied Mechanics Program Northwestern University 2145 Sheridan Road Evanston IL 60208 USA
| | - Neda Latifi
- Department of Mechanical and Industrial Engineering University of Toronto 5 King's College Road Toronto ON M5S 3G8 Canada
| | - Francesco Giovanniello
- Department of Mechanical Engineering McGill University 817 Sherbrooke Street West Montreal QC H3A 0C3 Canada
| | - Horacio D. Espinosa
- Theoretical and Applied Mechanics Program Northwestern University 2145 Sheridan Road Evanston IL 60208 USA
| | - Marco Amabili
- Department of Mechanical Engineering McGill University 817 Sherbrooke Street West Montreal QC H3A 0C3 Canada
| |
Collapse
|
41
|
Role of smooth muscle activation in the static and dynamic mechanical characterization of human aortas. Proc Natl Acad Sci U S A 2022; 119:2117232119. [PMID: 35022244 PMCID: PMC8784113 DOI: 10.1073/pnas.2117232119] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/02/2021] [Indexed: 12/14/2022] Open
Abstract
The rupture of aortic aneurysms causes around 10,000 deaths each year in the United States. Prosthetic tubes for aortic repair present a large mismatch of mechanical properties with the natural aorta, which has negative consequences for perfusion. This motivates research into the mechanical characterization of human aortas to develop a new generation of mechanically compatible aortic grafts. Experimental data and a suitable material model for human aortas with vascular smooth muscle (VSM) activation are not available. Hence, the present study provides experimental data that are needed. These data made it possible to develop a precise structure-based model of active aortic tissue. The results show the importance of VSM activation on the static and dynamic mechanical response of human aortas. Experimental data and a suitable material model for human aortas with smooth muscle activation are not available in the literature despite the need for developing advanced grafts; the present study closes this gap. Mechanical characterization of human descending thoracic aortas was performed with and without vascular smooth muscle (VSM) activation. Specimens were taken from 13 heart-beating donors. The aortic segments were cooled in Belzer UW solution during transport and tested within a few hours after explantation. VSM activation was achieved through the use of potassium depolarization and noradrenaline as vasoactive agents. In addition to isometric activation experiments, the quasistatic passive and active stress–strain curves were obtained for circumferential and longitudinal strips of the aortic material. This characterization made it possible to create an original mechanical model of the active aortic material that accurately fits the experimental data. The dynamic mechanical characterization was executed using cyclic strain at different frequencies of physiological interest. An initial prestretch, which corresponded to the physiological conditions, was applied before cyclic loading. Dynamic tests made it possible to identify the differences in the viscoelastic behavior of the passive and active tissue. This work illustrates the importance of VSM activation for the static and dynamic mechanical response of human aortas. Most importantly, this study provides material data and a material model for the development of a future generation of active aortic grafts that mimic natural behavior and help regulate blood pressure.
Collapse
|
42
|
Membrane curvature and connective fiber alignment in guinea pig round window membrane. Acta Biomater 2021; 136:343-362. [PMID: 34563725 DOI: 10.1016/j.actbio.2021.09.036] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 09/14/2021] [Accepted: 09/17/2021] [Indexed: 11/23/2022]
Abstract
The round window membrane (RWM) covers an opening between the perilymph fluid-filled inner ear space and the air-filled middle ear space. As the only non-osseous barrier between these two spaces, the RWM is an ideal candidate for aspiration of perilymph for diagnostics purposes and delivery of medication for treatment of inner ear disorders. Routine access across the RWM requires the development of new surgical tools whose design can only be optimized with a thorough understanding of the RWM's structure and properties. The RWM possesses a layer of collagen and elastic fibers so characterization of the distribution and orientation of these fibers is essential. Confocal and two-photon microscopy were conducted on intact RWMs in a guinea pig model to characterize the distribution of collagen and elastic fibers. The fibers were imaged via second-harmonic-generation, autofluorescence, and Rhodamine B staining. Quantitative analyses of both fiber orientation and geometrical properties of the RWM uncovered a significant correlation between mean fiber orientations and directions of zero curvature in some portions of the RWM, with an even more significant correlation between the mean fiber orientations and linear distance along the RWM in a direction approximately parallel to the cochlear axis. The measured mean fiber directions and dispersions can be incorporated into a generalized structure tensor for use in the development of continuum anisotropic mechanical constitutive models that in turn will enable optimization of surgical tools to access the cochlea. STATEMENT OF SIGNIFICANCE: The Round Window Membrane (RWM) is the only non-osseous barrier separating the middle and inner ear spaces, and thus is an ideal portal for medical access to the cochlea. An understanding of RWM structure and mechanical response is necessary to optimize the design of surgical tools for this purpose. The RWM geometry and the connective fiber orientation and dispersion are measured via confocal and 2-photon microscopy. A region of the RWM geometry is characterized as a hyperbolic paraboloid and another region as a tapered parabolic cylinder. Predominant fiber directions correlate well with directions of zero curvature in the hyperbolic paraboloid region. Overall fiber directions correlate well with position along a line approximately parallel to the central axis of the cochlea's spiral.
Collapse
|
43
|
Weissmann J, Charles CJ, Richards AM, Yap CH, Marom G. Cardiac mesh morphing method for finite element modeling of heart failure with preserved ejection fraction. J Mech Behav Biomed Mater 2021; 126:104937. [PMID: 34979481 DOI: 10.1016/j.jmbbm.2021.104937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 10/21/2021] [Accepted: 10/24/2021] [Indexed: 10/20/2022]
Abstract
Numerical modeling of heart biomechanics can realistically capture morphological variations in diseases and has been helpful in advancing our understanding of the physiology. Subject-specific models require anatomic representation of medical images, and it is desirable to have a consistently repeatable models for any given morphology. In this study, we propose a novel and easily adaptable cardiac reconstruction algorithm by morphing an existing discretized mesh of an advanced finite element (FE) model, to match anatomies acquired from porcine cardiac magnetic resonance imaging (cMRI) scans. The morphing algorithm involves iterative FE simulations with visco-hyperelastic material properties. The living heart porcine model (LHPM) was chosen as the input baseline FE mesh, in order to preserve detailed anatomical features that cannot be captured in routine scans such as myofiber orientations and conduction pathways. The algorithm was demonstrated for the recreation of porcine hearts of a healthy subject and of a subject induced with heart failure with preserved ejection fraction (HFpEF) conditions, where there were substantial hypertrophy and anatomical alterations. We further used the morphed meshes for FE modeling of cardiac contraction and relaxation, thus demonstrating the applicability of the proposed algorithm in producing viable meshes. The results show that our algorithm can recreate the characteristic anatomical changes of cardiac remodeling, including heart muscle thickening, as well as replicate the reduction in ventricular volume. This algorithm allows for the creation of subject-specific models with the same mesh connectivity, thus enabling spatial comparison and analysis of pathologic progress.
Collapse
Affiliation(s)
| | - Christopher J Charles
- Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore; Cardiovascular Research Institute, National University of Singapore, Singapore; Christchurch Heart Institute, Department of Medicine, University of Otago, Christchurch, New Zealand
| | - A Mark Richards
- Cardiovascular Research Institute, National University of Singapore, Singapore; Christchurch Heart Institute, Department of Medicine, University of Otago, Christchurch, New Zealand
| | - Choon Hwai Yap
- Department of Bioengineering, Imperial College London, UK
| | - Gil Marom
- School of Mechanical Engineering, Tel Aviv University, Israel.
| |
Collapse
|