1
|
Taylor M, Callary S, Thewlis D, Bryan R. The Influence of Cup Orientation on the Primary Fixation of a Hemispherical Cementless Acetabular Cup: A Cohort Based Finite Element Study. J Orthop Res 2025. [PMID: 40221868 DOI: 10.1002/jor.26084] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/22/2024] [Revised: 02/25/2025] [Accepted: 03/26/2025] [Indexed: 04/15/2025]
Abstract
Cup orientation has been investigated in detail with respect to risk of dislocation, however, the impact on the primary fixation of cementless cups is poorly understood. The aim of this study was to assess the influence acetabular component orientation on the primary fixation of cementless acetabular cups using an in silico clinical trial framework. Finite element models of 57 implanted hemi-pelves were generated from CT scans of a cohort of end stage osteoarthritis patients. Each hemi-pelvis was implanted with the with cup orientations that bounded the Lewinnek safe zone (mechanical alignment +/-10 degrees) and an approximation of the extreme orientations reported in the literature (mechanical alignment +/-20 degrees). Bone strain immediately adjacent to the implant and micromotions (gap and shear micromotions) were used to assess primary fixation. Analysis was performed at the levels of the individual subjects and the entire cohort. There was minimal variation in all metrics within the Lewinnek safe zone. Micromotion, particularly inferior gaping, was more sensitive to cup orientation than peri-prosthetic bone strain, tending to increase with inclination angle. Both the peri-prosthetic bone strains and micromotions were moderately correlated to the average bone modulus. Individuals with low bone modulus were shown to be more sensitive to changes in cup orientation for both peri-prosthetic bone strains and micromotions both within and outside the Lewinnek safe zone. This suggests that assessing bone quality should be routinely incorporated into the planning process, particularly when considering cup orientations outside of the Lewinnek safe zone.
Collapse
Affiliation(s)
- Mark Taylor
- Medical Device Research Institute, College of Science and Engineering, Flinders University, Tonsley, South Australia, Australia
| | - Stuart Callary
- Centre for Orthopaedic and Trauma Research, The Adelaide Medical School, University of Adelaide, Adelaide, South Australia, Australia
- Department of Orthopaedics and Trauma, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - Dominic Thewlis
- Centre for Orthopaedic and Trauma Research, The Adelaide Medical School, University of Adelaide, Adelaide, South Australia, Australia
| | | |
Collapse
|
2
|
Sacher SE, A O'Donnell J, Wright TM, Debbi EM, Padgett DE. Robotic-Assisted Surgery Does Not Decrease Prosthetic Impingement in Total Hip Arthroplasty: A Retrieval Analysis. J Arthroplasty 2025:S0883-5403(25)00205-0. [PMID: 40057210 DOI: 10.1016/j.arth.2025.02.077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2024] [Revised: 02/26/2025] [Accepted: 02/27/2025] [Indexed: 04/01/2025] Open
Abstract
BACKGROUND Prosthetic impingement after total hip arthroplasty (THA) has been associated with instability and may be a cause of accelerated polyethylene wear and pain. Previous retrieval studies report a high prevalence of impingement in acetabular liners. Robotic technology has the potential to reduce THA instability as it enables technical precision and optimizes implant positioning. However, whether robotics can improve impingement prevalence is unknown. Thus, the objectives of this study were to: (1) determine the prevalence and severity of acetabular liner impingement with robotic navigation; and (2) compare impingement prevalence with a control cohort of manually placed THA liners. METHODS There were 18 robotic-assisted liners and 11 non-robotic controls scored for the presence and severity of impingement. Radiographic measurements of acetabular inclination and anteversion were assessed using prerevision standing radiographs. Femoral head size (36 being the most common), length of implantation, revision indication, age, gender, and body mass index were recorded. RESULTS Of the robotic liners, 61% showed impingement, while 45% of the non-robotic liners showed impingement (P = 0.14). The robotic group demonstrated a lower variance of inclination (robotic: 41.7° ± 3.9, control: 42.8° ± 7.1, P = 0.64) and lower anteversion variance (robotic: 22.8° ± 2.8, control: 20.8° ± 7.9, P = 0.43), but mean values did not differ between the groups. Impingement presence and severity were not related to head size, length of implantation, or other demographic variables. CONCLUSIONS This study suggests that the use of robotic-assisted technology employing modern-day implants with larger diameter heads does not reduce the prevalence or severity of prosthetic impingement in retrieved acetabular liners from revision THA.
Collapse
Affiliation(s)
- Sara E Sacher
- Department of Biomechanics, Hospital for Special Surgery, New York, New York
| | - Jeffrey A O'Donnell
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Timothy M Wright
- Department of Biomechanics, Hospital for Special Surgery, New York, New York
| | - Eytan M Debbi
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| | - Douglas E Padgett
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, New York
| |
Collapse
|
3
|
Kaji ES, Grove AF, Mulford KL, Larson DR, Labott JR, Roman RD, Sierra RJ, Taunton MJ, Wyles CC. The Impact of Leg Length and Offset Change on Dislocation Risk Following Primary Total Hip Arthroplasty. J Arthroplasty 2025; 40:725-731. [PMID: 39284396 DOI: 10.1016/j.arth.2024.09.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/18/2024] [Revised: 09/06/2024] [Accepted: 09/10/2024] [Indexed: 10/11/2024] Open
Abstract
BACKGROUND Soft tissue management in total hip arthroplasty includes appropriate restoration and/or alteration of leg length (LL) and offset to re-establish natural hip biomechanics. The purpose of this study was to evaluate the effect of LL and offset-derived variables in a multivariable survival model for dislocation. METHODS Clinical, surgical, and radiographic data was retrospectively acquired for 12,582 patients undergoing primary total hip arthroplasty at a single institution from 1998 to 2018. There were twelve variables derived from preoperative and postoperative radiographs related to LL and offset that were measured using a validated automated algorithm. These measurements, as well as other modifiable and nonmodifiable surgical, clinical, and demographic factors, were used to determine hazard ratios for dislocation risk. RESULTS None of the LL or offset variables conferred significant risk or protective benefit for dislocation risk. By contrast, all other variables included in the multivariable model demonstrated a statistically significant effect on dislocation risk with a minimum effect size of 28% (range 0.72 to 1.54) (sex, surgical approach, acetabular liner type, femoral head size, neurologic disease, spine disease, and prior spine surgery). CONCLUSIONS Contrary to traditional teaching and our hypothesis, operative changes in LL and offset did not demonstrate any clinically or statistically significant effect in this large and well-characterized cohort. This does not imply that these variables are not important in individual cases, but rather suggests the overall impact of LL and offset changes is relatively minor for dislocation risk compared to other variables that were found to be highly clinically and statistically significant in this population. These results may also suggest that surgeons do a good job of restoring native LL and offset for patients, which may mitigate their analyzed impact.
Collapse
Affiliation(s)
- Elizabeth S Kaji
- Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Austin F Grove
- Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Kellen L Mulford
- Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Dirk R Larson
- Division of Biomedical Statistics and Informatics, Mayo Clinic, Rochest, Minnesota
| | - Joshua R Labott
- Mayo Clinic Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Ryan D Roman
- Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Rafael J Sierra
- Mayo Clinic Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Michael J Taunton
- Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota; Mayo Clinic Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| | - Cody C Wyles
- Orthopedic Surgery Artificial Intelligence Laboratory, Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota; Mayo Clinic Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota
| |
Collapse
|
4
|
Verhaegen JCF, Innmann M, Vorimore C, Merle C, Grammatopoulos G. Achieving cup target as per spinopelvic assessment is associated with improved THA outcome: a prospective, multicentre study. Hip Int 2025; 35:130-141. [PMID: 39865697 DOI: 10.1177/11207000241312654] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2025]
Abstract
BACKGROUND Different methods can help to optimise sagittal cup orientation in total hip arthroplasty (THA) based on individual spinopelvic characteristics. This study aimed to: (1) assess how often combined sagittal index (CSI) and hip-spine-classification targets were achieved post THA; (2) compare anteversion/inclination between cups in-/outside optimal CSI zone; and (3) determine association with outcome. METHODS This is a multicentre, prospective, case-cohort study of 435 primary THA for osteoarthritis (53% females; age: 65 ± 12 years; follow-up: 2.4 ± 0.6 years) (58% lateral, 29% anterior, 13% posterior approach). No robotics or dual-mobility were used. Patients underwent spinopelvic radiographs to measure parameters including lumbar lordosis (LL), sacral slope (SS), pelvic tilt (PT), pelvic incidence (PI), pelvic femoral angle (PFA), and ante-inclination (AI) on lateral spinopelvic radiographs. Unbalanced spine was defined as PI - LL ⩾ 10° (PI: pelvic incidence; LL: lumbar lordosis), stiffness as ∆LL < 20°. Optimal cup orientation was based on CSI targets: 205-245° for balanced spine (n = 327), or 215-235° for unbalanced spine (n = 108), hip-spine classification targets (±5°), and conventional inclination/anteversion (40/20° ± 10°) target. Patient-reported outcome was measured using Oxford Hip Score (OHS). RESULTS CSI targets were achieved in 60% (n = 261/435), whilst 44% had cup position within hip-spine classification targets (n = 125/284). Anteversion was higher among cups within CSI targets (26° ± 8° vs. 22° ± 10°; p < 0.001). Overall dislocation rate was 0.9% (n = 4/435), without difference whether CSI targets were achieved (0.4% vs. 1.7%; p = 0.178). Postoperative OHS was better among those within CSI targets (42 ± 8 vs. 40 ± 9; p = 0.003) or within hip-spine-classification targets (p = 0.028), but not according to conventional orientation (p = 0.384). CONCLUSIONS Awareness of adverse spinopelvic characteristics and using sagittal characteristics (especially CSI) can help surgeons to achieve optimal cup orientation, improving outcome and reducing dislocation risk post-THA.
Collapse
Affiliation(s)
- Jeroen C F Verhaegen
- Department of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada
- Department of Orthopaedics and Traumatology, University Hospital Antwerp, Edegem, Belgium
- Orthopaedic Centre Antwerp, AZ Monica, Antwerp, Belgium
| | - Moritz Innmann
- Department of Orthopaedics and Trauma Surgery, University Hospital Heidelberg, Heidelberg, Germany
| | - Camille Vorimore
- Department of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada
| | | | | |
Collapse
|
5
|
Ram Sudhan S, Surendran S, Gopinath NP, C U J, Muhammed Fazil V, Gopinathan P, Nikhil K. Spinopelvic alignment and precise cup placement in total hip arthroplasty - A systematic review. J Orthop 2025; 60:105-114. [PMID: 39399321 PMCID: PMC11470479 DOI: 10.1016/j.jor.2024.08.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2024] [Accepted: 08/11/2024] [Indexed: 10/15/2024] Open
Abstract
Study Design A systematic literature review and meta- analysis. Objective To extract and combine the available literature focused on normal and abnormal biomechanical principles of spine-pelvis-hip complex and to sum up the data in the application of THA both in the setting with and without spinal disorders. Methods An extensive search and analysis of the articles was done by 3 authors independently in 7 platforms based on PRISMA and MOOSE guidelines. Selection criteria 1. Articles that assessed spinopelvic parameters (SS, SPT, PI, and acetabular cup orientation) in patients undergoing THA, Articles that assessed balance in spinopelvic complex after THA, Randomized control studies, Systematic literature reviews, Meta-analyses, Clinical trials / original research studies, Review articles and Articles after 2015 were included. Cochrane's GRADE method was used to define the level of evidence. 2.Participants: Patients who underwent THA only (in asymptomatic spine), those who had ankylosing spondylitis and underwent THA and those who underwent THA with prior spinal arthrodesis. 3.Study parameters: Ante Inclination (AI), sacral slope (SS), pelvic Incidence (PI) and spinopelvic tilt (SPT) in both positions of standing and sitting. ΔAI, ΔSS and ΔSPT. Data were collected and analyzed, the means of the study parameters with SD were calculated and a meta-analysis is performed to evaluate the pooled means with optimal value range. Results From 218 abstracts extracted and after eligibility assessment and exclusion, 4 articles involving 439 patients were enrolled. The mean SS in standing and sitting calculated were 35.53±10.52 and 33.13±12.38. The mean of AI and SPT in standing /sitting positions are 29.7±12.29/34.69±12.96 (n = 242) and 19.56±8.9/21.22±12.53 (n=439) respectively. The ΔAI, ΔSS, and ΔSPT were 4.99,2.4 and 1.66 respectively. Conclusion There is a proportionate change between the spinopelvic tilt and the acetabular orientation in postural variations. Evaluation of spine, pelvis and hip becomes more critical in identifying these changes and thereby prompting the acetabular cup position in the functional safe zone.
Collapse
Affiliation(s)
- S. Ram Sudhan
- Fellow in Arthroplasty, Sports surgery & Rehabilitation, Yenepoya Medical College Hospital, Yenepoya University, Deralakatte, Karnataka, 575018, India
| | - Sibin Surendran
- Department of Orthopaedics, Government Medical College, Kozhikode, Kerala, 673008, India
| | - Naveen P. Gopinath
- Department of Orthopaedics, GMC Ortho Foundation Hospital and Research Centre, Kozhikode, Kerala, 673011, India
| | - Jijulal C U
- Department of Orthopaedics, GMC Ortho Foundation Hospital and Research Centre, Kozhikode, Kerala, 673011, India
| | | | - P. Gopinathan
- Department of Orthopaedics, GMC Ortho Foundation Hospital and Research Centre, Kozhikode, Kerala, 673011, India
| | - K.V. Nikhil
- Meitra Hospital, Kozhikode, Kerala, 673005, India
| |
Collapse
|
6
|
Iorio R, Viglietta E, Corsetti F, Gugliotta Y, Massafra C, Polverari D, Redler A, Maffulli N. Lewinnek zone not "the be-all and end-all" functional planning for acetabular component positioning in total hip arthroplasty. ARTHROPLASTY 2025; 7:2. [PMID: 39757219 DOI: 10.1186/s42836-024-00284-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2024] [Accepted: 10/22/2024] [Indexed: 01/07/2025] Open
Abstract
BACKGROUND Proper positioning of a total hip arthroplasty (THA) plays a crucial role in the success and long-term survivorship of the implant. Cup positioning within the Lewinnek Safe Zone (LSZ) does not, however, avoid implant dislocation. Thus, the concept of a functional cup position has been introduced. The purpose of this study was to assess the discrepancy between LSZ and the acetabular cup position suggested by the patient's specific functional planning. The hypothesis was that a mismatch does exist. METHODS One hundred consecutive patients with primary hip osteoarthritis undergoing primary THA with a personalized functional preoperative planning and patient-specific cup implantation system were enrolled. Anatomical and spino-pelvic functional parameters were recorded and, for each patient, a "safe cup orientation" was suggested. The suggested functional safe zone was compared to the LSZ. RESULTS The mean suggested inclination was 39° ± 3° (range 32°-45°). The mean suggested anteversion was 21° ± 3° (range 12°-28°). The patient's functional acetabular inclination (AI) corresponded to the LSZ in one of the 100 patients, whereas the acetabular anteversion (AV) was outside the LSZ in 8 of the 100 patients. The mean pelvic tilt while standing and sitting were 0.5° ± 7° (range 21°-45°) and -6° ± 16.7° (range -63°-33°), respectively. The mean pelvic incidence was 52° ± 9.7° (range 33°-83°). CONCLUSION When a functional patient's specific preoperative planning is performed, the LZS does not correspond to the patient's functional safe zone in about 8% of patients. The concept of a universal safe zone should be revisited, and a functional personalized safe zone may have to be more widely considered.
Collapse
Affiliation(s)
- Raffaele Iorio
- Sant'Andrea Hospital, Faculty of Medicine and Psychology, Sapienza University of Rome, 00162, Rome, Italy
| | - Edoardo Viglietta
- Sant'Andrea Hospital, Faculty of Medicine and Psychology, Sapienza University of Rome, 00162, Rome, Italy
| | - Federico Corsetti
- Sant'Andrea Hospital, Faculty of Medicine and Psychology, Sapienza University of Rome, 00162, Rome, Italy
| | - Yuri Gugliotta
- Sant'Andrea Hospital, Faculty of Medicine and Psychology, Sapienza University of Rome, 00162, Rome, Italy
| | - Carlo Massafra
- Sandro Pertini Hospital, Orthopedic and Traumatology Unit, 00162, Rome, Italy
| | - Daniele Polverari
- Sant'Andrea Hospital, Faculty of Medicine and Psychology, Sapienza University of Rome, 00162, Rome, Italy
| | - Andrea Redler
- Sant'Andrea Hospital, Faculty of Medicine and Psychology, Sapienza University of Rome, 00162, Rome, Italy
| | - Nicola Maffulli
- Sant'Andrea Hospital, Faculty of Medicine and Psychology, Sapienza University of Rome, 00162, Rome, Italy.
- School of Pharmacy and Bioengineering, Keele University Faculty of Medicine, Stoke On Trent, ST4 7QB, UK.
- Centre for Sports and Exercise Medicine, Barts and the London School of Medicine and Dentistry, Mile End Hospital, Queen Mary University of London, London, E1 4DG, UK.
| |
Collapse
|
7
|
Iwasa M, Nakahara I, Miki H. Large cohort study on prevention strategies for dislocation in total hip arthroplasty. J Orthop Sci 2024:S0949-2658(24)00194-5. [PMID: 39537524 DOI: 10.1016/j.jos.2024.10.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2024] [Revised: 08/26/2024] [Accepted: 10/01/2024] [Indexed: 11/16/2024]
Abstract
BACKGROUND Dislocation is a major complication of total hip arthroplasty (THA). This study aimed to assess the dislocation rate after THA using the combined strategy of using CT-based navigation, large diameter heads, and posterior soft tissue repair in a large cohort. METHODS We included 1410 patients who had undergone primary cementless THA using the CT-based navigation system. The posterior approach was used by a single surgeon for all patients. The participants included 143 (10.1 %) men and 1267 (89.9 %) women, with a mean age of 65 years. The mean body mass index was 24 kg/m2. Additionally, the incidence rate of postoperative dislocation per year was calculated. The dislocation onset was classified as early when the dislocation occurred within 2 years of the primary THA and late when it occurred more than 2 years after the primary THA. Recurrence and revision rates in patients with dislocations were investigated. RESULTS The postoperative dislocation rate was 0.56 % (8 patients). The mean time to dislocation onset was 11.2 (0.5-20.0) months postoperatively. All postoperative dislocations occurred in the early phase whereas none in the late phase, showing a significant difference (p < 0.01). Six (0.43 %) patients experienced recurrent dislocations or required revision. CONCLUSIONS THA using the combined strategy resulted in low dislocation rates, especially without late dislocation.
Collapse
Affiliation(s)
- Makoto Iwasa
- Department of Orthopaedic Surgery, National Hospital Organization Osaka National Hospital, Japan.
| | - Ichiro Nakahara
- Department of Orthopaedic Surgery, National Hospital Organization Osaka Minami Medical Center, Japan
| | - Hidenobu Miki
- Department of Orthopaedic Surgery, National Hospital Organization Osaka National Hospital, Japan
| |
Collapse
|
8
|
Bostancı B, Azboy N, Kürşat Yılmaz M, Akif Çaçan M, Azboy İ. Assessment of spinopelvic relationship among Turkish orthopedic surgeons in total joint replacement: a survey. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA 2024; 58:296-300. [PMID: 39560971 PMCID: PMC11583933 DOI: 10.5152/j.aott.2024.23085] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Accepted: 07/31/2024] [Indexed: 11/20/2024]
Abstract
Objective This study aims to investigate the preferences of orthopedics and traumatology specialists in evaluating the spinopelvic relationship in primary total hip arthroplasty (THA) in Türkiye. Methods Members of the Turkish Orthopedics and Traumatology Association (n=2485) were invited to fill out the questionnaire. The survey was created using Google Forms and distributed to participants via WhatsApp and Gmail by sharing the link. A total of 205 orthopedic surgeons responded and completed the questionnaire. The survey included 13 questions about the duration of their experience, the number of THA and spinal instrumentation procedures they performed, the dislocation rates they encountered after surgery, and the radiological assessments they performed for the spinopelvic relationship. Results Sixty-three percent of the participants evaluated spinopelvic parameters in patients undergoing THA. Forty-seven percent of surgeons state that in their daily practice, they determine the angle of the acetabular component according to whether the spinal deformity is rigid, flexible, balanced, or unstable. While 88% of the participants stated the rate of encountering dislocation after primary THA as less than 2%, 12% of the participants stated it as more than 2%. It was observed that 40% of the surgeons with a prosthetic dislocation rate of more than 2% evaluated the spinopelvic relationship, while 67% of the surgeons with a dislocation rate of less than 2% evaluated the spinopelvic relationship. Conclusion Approximately half of the orthopedic surgeons in Türkiye plan component placement in primary THA cases by considering the spinopelvic relationship. In order to increase awareness about the spinopelvic relationship, it would be beneficial to give more space to this subject in training programs and conferences. Level of Evidence N/A.
Collapse
Affiliation(s)
- Bilal Bostancı
- Department of Orthopedic and Traumatology, Medipol Mega University Hospital, Istanbul, Türkiye
| | - Nesrullah Azboy
- Department of Orthopedic and Traumatology, Medipol Mega University Hospital, Istanbul, Türkiye
| | - Mehmet Kürşat Yılmaz
- Department of Orthopedic and Traumatology, Medipol Mega University Hospital, Istanbul, Türkiye
| | - Mehmet Akif Çaçan
- Department of Orthopedic and Traumatology, Medipol Mega University Hospital, Istanbul, Türkiye
| | - İbrahim Azboy
- Department of Orthopedic and Traumatology, Medipol Mega University Hospital, Istanbul, Türkiye
| |
Collapse
|
9
|
Farey JE, Chai Y, Xu J, Maes V, Sadeghpour A, Baker NA, Vigdorchik JM, Walter WL. Evaluating Alternative Registration Planes in Imageless, Computer-Assisted Navigation Systems for Direct Anterior Total Hip Arthroplasty. SENSORS (BASEL, SWITZERLAND) 2024; 24:7092. [PMID: 39517988 PMCID: PMC11548659 DOI: 10.3390/s24217092] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2024] [Revised: 10/27/2024] [Accepted: 10/30/2024] [Indexed: 11/16/2024]
Abstract
(1) Background: Imageless computer navigation systems have the potential to improve the accuracy of acetabular cup position in total hip arthroplasty (THA). Popular imageless navigation methods include locating the patient in a three-dimensional space (registration method) while using a baseline to angle the acetabular cup (reference plane). This study aims to compare the accuracy of different methods for determining postoperative acetabular cup positioning in THA via the direct anterior approach. (2) Methods: Fifty-one participants were recruited. Optical and inertial sensor imageless navigation systems were used simultaneously with three combinations of registration methods and reference planes: the anterior pelvic plane (APP), the anterior superior iliac spine (ASIS) and the table tilt (TT) method. Postoperative acetabular cup position, inclination, and anteversion were assessed using CT scans. (3) Results: For inclination, the mean absolute error (MAE) was lower using the TT method (2.4° ± 1.7°) compared to the ASIS (2.8° ± 1.7°, p = 0.17) and APP method (3.7° ± 2.1°, p < 0.001). For anteversion, the MAE was significantly lower for the TT method (2.4° ± 1.8°) in contrast to the ASIS (3.9° ± 3.2°, p = 0.005) and APP method (9.1° ± 6.2°, p < 0.001). (4) Conclusion: A functional reference plane is superior to an anatomic reference plane to accurately measure intraoperative acetabular cup inclination and anteversion in THA using inertial imageless navigation systems.
Collapse
Affiliation(s)
- John E. Farey
- Sydney Musculoskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Camperdown, NSW 2064, Australia (W.L.W.)
| | - Yuan Chai
- Sydney Musculoskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Camperdown, NSW 2064, Australia (W.L.W.)
- Institute of Future Health, South China University of Technology, Guangzhou 511442, China
| | - Joshua Xu
- Department of Orthopedics and Traumatic Surgery, Royal North Shore Hospital, St Leonards, NSW 2065, Australia
| | - Vincent Maes
- Sydney Musculoskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Camperdown, NSW 2064, Australia (W.L.W.)
- Department of Orthopedic Surgery, University Hospitals Leuven, Herestraat 49, 3000 Leuven, Belgium
| | | | - Neri A. Baker
- Innovation Department, Navbit, Sydney, NSW 2000, Australia (N.A.B.)
| | - Jonathan M. Vigdorchik
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY 10021, USA;
| | - William L. Walter
- Sydney Musculoskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Camperdown, NSW 2064, Australia (W.L.W.)
- Department of Orthopedics and Traumatic Surgery, Royal North Shore Hospital, St Leonards, NSW 2065, Australia
| |
Collapse
|
10
|
LaValva SM, Westrich GH, Marchand RC, Lall AC, Domb BG, Vigdorchik JM, Jerabek SA. A multicentre prospective assessment of the utility of robotic assisted total hip arthroplasty with virtual range of motion on intraoperative implant positioning. Hip Int 2024; 34:717-723. [PMID: 38916080 DOI: 10.1177/11207000241254353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/26/2024]
Abstract
BACKGROUND The growing adoption of robotic-assistance during total hip arthroplasty (THA) has provided novel means through which a patient's anatomy and dynamic spinopelvic relationship can be incorporated into surgical planning. However, the impact of enhanced technologies on intraoperative decision-making and changes to component positioning has not yet been described. METHODS A multicentre, prospective study included 105 patients (52% women) patients who underwent robotic-assisted THA with the integration of software that incorporates a patient's pelvic tilt (PT) and virtual range-of-motion (VROM) for impingement modeling. The primary outcome of the study was the percentage of patients who underwent changes to the preoperative plan for cup position after incorporating the data from the software. RESULTS Utilising the intraoperative VROM information, the preoperative plan for cup position was changed from the default (40° inclination and 20° anteversion) in 82/105 (78%) cases. When stratifying by spinopelvic mobility, 64% were considered normal (change ⩾ 10° and ⩽30°), 27% were stiff (change < 10°), and 9% were hypermobile (change > 30°). For all cohorts, the majority of cases (78%) deviated from the 40° inclination and 20° version target. When evaluating the proportion of cases within the Lewinnek and Callanan safe zones based on spinopelvic mobility, 19% of cases within the normal group were planned outside of both zones compared to 39% of stiff cases and 10% of hypermobile cases. CONCLUSIONS Utilising the latest version of robotic-assisted THA software, the preoperative plan for cup position was changed in the vast majority (78%) of patients, causing substantial deviations from traditional, generic cup targets.
Collapse
Affiliation(s)
- Scott M LaValva
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY, USA
| | - Geoffrey H Westrich
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY, USA
| | | | - Ajay C Lall
- American Hip Institute, Des Plaines, IL, USA
| | | | - Jonathan M Vigdorchik
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY, USA
| | - Seth A Jerabek
- Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, New York, NY, USA
| |
Collapse
|
11
|
Tokuyasu H, Tsushima E, Takemoto M, Vergari C, Tada H, Kim Y. The Impact of Spinopelvic and Hip Mobility on Passive Hip Flexion Range of Motion Assessment. Arthroplast Today 2024; 29:101429. [PMID: 39328882 PMCID: PMC11424763 DOI: 10.1016/j.artd.2024.101429] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 04/03/2024] [Accepted: 05/01/2024] [Indexed: 09/28/2024] Open
Abstract
Background Measuring passive hip flexion range of motion (ROM) is challenging due to compensatory movements. Despite the interest in using functional lateral radiographs for assessing hip mobility, the relationship with passive hip flexion ROM remains unclear. This study aims to elucidate this relationship and clarify spinopelvic parameters and mobility factors influencing variations in passive and radiographic hip flexion ROM. Methods A retrospective cross-sectional study was conducted on 154 preoperative patients undergoing primary total hip arthroplasty. Passive and radiographic hip flexion ROM were assessed to clarify these relationships, and these differences were classified into 3 groups (O, A and U). Spinopelvic and hip parameters were assessed in standing, relaxed-seated and flexed-seated positions, as well as lumbar, pelvis, and hip mobility between each position to identify factors influencing differences. Results There was a moderate correlation between passive and radiographic hip flexion ROM (R2 = 0.48, P < .01). A significant difference was found in pelvic and hip alignment in the flexed-seated position between all groups. In postural changes, the O group, which had more patients with relatively low hip mobility, showed greater lumbar spine and pelvic movement, while the U group, which had more patients with relatively high hip mobility, showed less lumbar spine and pelvic movement. Conclusions This study confirmed that passive hip flexion ROM and radiographic hip flexion ROM correlate and that spinopelvic and hip alignment and mobility influence these differences. This result suggests that clinicians should consider lumbar and pelvic alignment and mobility in clinical practice to improve the accuracy of passive hip flexion ROM measurements.
Collapse
Affiliation(s)
- Hiroyuki Tokuyasu
- Department of Rehabilitation, Kyoto City Hospital, Kyoto, Japan
- Graduate School of Health Sciences, Hirosaki University, Hirosaki, Aomori, Japan
| | - Eiki Tsushima
- Graduate School of Health Sciences, Hirosaki University, Hirosaki, Aomori, Japan
| | - Mitsuru Takemoto
- Department of Orthopaedic Surgery, Kyoto City Hospital, Kyoto, Japan
| | - Claudio Vergari
- Arts et Métiers Institute of Technology, Institut de Biomécanique Humaine Georges Charpak, Université Sorbonne Paris Nord, Paris, France
| | - Hiroshi Tada
- Department of Rehabilitation, Kyoto City Hospital, Kyoto, Japan
| | - Youngwoo Kim
- Department of Orthopaedic Surgery, Kyoto City Hospital, Kyoto, Japan
| |
Collapse
|
12
|
Chai Y, Boudali AM, Veltman ES, Farey JE, Walter WL. Evaluating pelvic tilt using the pelvic antero-posterior radiographs: A novel method. J Orthop Res 2024; 42:2318-2326. [PMID: 38814154 DOI: 10.1002/jor.25907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 04/12/2024] [Accepted: 05/12/2024] [Indexed: 05/31/2024]
Abstract
Pelvic tilt (PT) is an important parameter for orthopedic surgeries involving hip and spine, typically determined from sagittal pelvic radiographs. However, various challenges can compromise the feasibility of measurement from sagittal imaging, including obscured landmarks, anatomical variations, hardware interference, and limited medical resources. Addressing these challenges and with the aim of reducing radiation exposure to patients, our study developed a novel method to estimate PT from antero-posterior (AP) radiographs, using vertical distances from the pelvic outlet and obturator foramen. We correlated these measurements with PT, defined both anatomically (anterior pelvic plane, PTa) and mechanically (centers of femoral heads and sacral plate, PTm). The study explored creating linear, exponential, and multivariate regression models based on twelve 3D CT-derived pelvic models (six men, six women), simulating AP radiograph projections with controlled PTs. We then validated these models against 105 pairs of patient stereoradiographs. Statistical analysis revealed that combined exponential-linear models yielded the most accurate results, with Pearson correlation coefficients of 0.75 for PTa and 0.77 for PTm, and mean absolute errors of 3.7° ± 2.6° for PTa and 4.5° ± 3.4° for PTm, showing excellent measurement reliability (all ICCs > 0.9) without significant gender discrepancies. In conclusion, this study presents a validated, simple, and accessible method for estimating PT using AP radiograph parameters, supported by the Supporting Information S1: Excel Tool, showing great potential for clinical application in hip and spine procedures.
Collapse
Affiliation(s)
- Yuan Chai
- Sydney Muskuloskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
- Institute of Future Health, South China University of Technology, Guangzhou, China
| | - A Mounir Boudali
- Sydney Muskuloskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - Ewout S Veltman
- Department of Orthopaedics and Traumatic Surgery, Royal North Shore Hospital, St. Leonards, New South Wales, Australia
| | - John E Farey
- Department of Orthopaedics and Traumatic Surgery, Royal North Shore Hospital, St. Leonards, New South Wales, Australia
| | - William L Walter
- Sydney Muskuloskeletal Health, Kolling Institute, Northern Clinical School, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
- Department of Orthopaedics and Traumatic Surgery, Royal North Shore Hospital, St. Leonards, New South Wales, Australia
| |
Collapse
|
13
|
Nemati HM, Christensson A, Pettersson A, Németh G, Flivik G. Precision of Cup Positioning Using a Novel Computed Tomography Based Navigation System in Total Hip Arthroplasty. MEDICINA (KAUNAS, LITHUANIA) 2024; 60:1589. [PMID: 39459376 PMCID: PMC11509289 DOI: 10.3390/medicina60101589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Revised: 09/09/2024] [Accepted: 09/24/2024] [Indexed: 10/28/2024]
Abstract
Background and Objectives: Navigation systems are designed to enhance surgical precision, improving patient outcomes and reducing the risk of implant misplacement. In this study, we have evaluated a novel orthopedic surgical platform that utilizes CT imaging with AI-based algorithms to automate several critical aspects of total hip arthroplasty. It contains three modules-preoperative planning, navigation during surgery, and follow-up analysis. The primary objective of the current study was to evaluate the precision of the navigation tool in cup placement, i.e., whether the information displayed for navigation correctly reflected the actual position of the implant. Materials and Methods: Surgery outcomes of 15 inter-rater measurements on human cadavers and 18 surgeries on patients who underwent total hip replacement using the navigation tool were analyzed. Results: In the inter-rater assessment, the mean errors were -0.31 ± 1.42° for anteversion, 1.06 ± 1.73° for inclination, and -0.94 ± 1.76 mm for cup position depth. In patients' surgeries, the mean errors were -0.07 ± 2.72° for anteversion, -0.2 ± 0.86° for inclination, and 0.28 ± 0.78 mm for cup depth. Conclusions: The navigation tool offers intra-operative guidance on notable precision in cup placement, thereby effectively mitigating the risk of cup malpositioning outside the patient-specific safe zone.
Collapse
Affiliation(s)
| | - Albin Christensson
- Department of Orthopedics, Clinical Sciences, Skåne University Hospital, Lund University, 221 84 Lund, Sweden
| | | | | | - Gunnar Flivik
- Department of Orthopedics, Clinical Sciences, Skåne University Hospital, Lund University, 221 84 Lund, Sweden
| |
Collapse
|
14
|
Pagano S, Plate JF, Kappenschneider T, Reinhard J, Scharf M, Maderbacher G. Polyethylene liner dissociation in total hip arthroplasty: a retrospective case-control study on a single implant design. J Orthop Traumatol 2024; 25:38. [PMID: 39143399 PMCID: PMC11324622 DOI: 10.1186/s10195-024-00785-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2024] [Accepted: 08/01/2024] [Indexed: 08/16/2024] Open
Abstract
BACKGROUND Modular acetabular components for total hip arthroplasty (THA) provide intraoperative flexibility; however, polyethylene liner dissociation may occur. This study aimed to examine the incidence and causes of liner dissociation associated with a specific acetabular component design at a single centre. MATERIALS AND METHODS A retrospective analysis of 7027 patients who underwent primary THA was performed to identify isolated liner dislocations. Patient demographics, clinical presentations, surgical and implant details, and both radiographic and computed tomography (CT) findings were analysed. Patients with liner dislocation were matched to a control group via 2:1 propensity score matching, and a logistic regression analysis was employed to identify associated risk factors. RESULTS A total of 32 patients (0.45%) experienced liner dislocation at a mean 71.47 ± 60.10 months post surgery. Significant factors contributing to dislocations included the use of a conventional compared with a highly crosslinked polyethylene component (p = 0.049) and screw fixation (p = 0.028). Radiographic and CT analysis highlighted the importance of proper component orientation, revealing that patients experiencing dislocations demonstrated significantly lower acetabular cup anteversion angles (p = 0.001) compared with the control group. Impingement and malposition, identified in 41% and 47% of the cases, respectively, further underscored the multifactorial nature of dislocation risks. CONCLUSIONS While the overall rate of polyethylene liner dislocation was low, the findings of this study highlight the importance of appropriate cup placement to decrease the risk of dissociation. It further substantiates the influence of impingement and malposition in liner displacement, with increased mechanical stress exerted on the locking mechanism under adverse conditions and the potential risk increase due to screw placement.
Collapse
Affiliation(s)
- S Pagano
- Department of Orthopaedic Surgery, University of Regensburg, Asklepios Klinikum, Kaiser-Karl-V.-Allee 3, 93077, Bad Abbach, Germany.
| | - J F Plate
- Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - T Kappenschneider
- Department of Orthopaedic Surgery, University of Regensburg, Asklepios Klinikum, Kaiser-Karl-V.-Allee 3, 93077, Bad Abbach, Germany
| | - J Reinhard
- Department of Orthopaedic Surgery, University of Regensburg, Asklepios Klinikum, Kaiser-Karl-V.-Allee 3, 93077, Bad Abbach, Germany
| | - M Scharf
- Department of Orthopaedic Surgery, University of Regensburg, Asklepios Klinikum, Kaiser-Karl-V.-Allee 3, 93077, Bad Abbach, Germany
| | - G Maderbacher
- Department of Orthopaedic Surgery, University of Regensburg, Asklepios Klinikum, Kaiser-Karl-V.-Allee 3, 93077, Bad Abbach, Germany
| |
Collapse
|
15
|
Fey B, Brenneis M, Stief F, van Drongelen S. Effect of Stem Design and Positioning on the Leg Axis after Total Hip Arthroplasty: A Secondary Analysis. J Clin Med 2024; 13:4453. [PMID: 39124720 PMCID: PMC11313081 DOI: 10.3390/jcm13154453] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 07/10/2024] [Accepted: 07/25/2024] [Indexed: 08/12/2024] Open
Abstract
Background/Objectives: Various parameters, like femoral offset and leg length, are associated with good patient outcomes after total hip arthroplasty. In this prospective study, the effects of stem design, its placement in the proximal femur and the resulting femoral offset on the total leg axis were investigated. Methods: The 27 patients included in this study received biplanar radiography (EOS®, EOS Imaging) with 3D reconstruction using sterEOS® both preoperatively and postoperatively. For all leg alignment parameters obtained from the 3D reconstruction and from measurements using mediCAD, the deltas between the postoperative and preoperative values were determined. Patients were divided into those who received a short-stem prosthesis and those who received a straight-stem prosthesis. Results: The change in femoral offset with the implantation of a short-stem prosthesis was significantly greater than that with the implantation of a straight-stem prosthesis (11.4 ± 5.9 vs. 4.6 ± 7.4 mm, p = 0.014). Compared with the straight-stem implantation, short-stem implantation caused a significantly greater increase in the varus orientation of the leg (-1.4 ± 0.9 vs. -0.4 ± 1.4°, p = 0.048). There was no significant difference in the positioning of the short-stem prosthesis compared to the straight-stem prosthesis in the proximal femur (3.6 ± 3.1 vs. 2.6 ± 1.9°, p = 0.317). Conclusions: These findings substantiate the impact of prosthesis design on offset and leg alignment. The implantation of short-stems is more variable and requires precise planning. Intraoperative non-physiological offset changes and varus deviation of the leg axis should be avoided. Trial registration: This study was retrospectively registered with the German Clinical Trials Register (DRKS) under the number DRKS00015053 on the 1 August 2018.
Collapse
Affiliation(s)
- Benjamin Fey
- Department of Trauma Surgery and Orthopedics, University Hospital Frankfurt, Goethe University Frankfurt, Marienburgstr. 2, 60528 Frankfurt, Germany; (B.F.); (M.B.); (F.S.)
| | - Marco Brenneis
- Department of Trauma Surgery and Orthopedics, University Hospital Frankfurt, Goethe University Frankfurt, Marienburgstr. 2, 60528 Frankfurt, Germany; (B.F.); (M.B.); (F.S.)
| | - Felix Stief
- Department of Trauma Surgery and Orthopedics, University Hospital Frankfurt, Goethe University Frankfurt, Marienburgstr. 2, 60528 Frankfurt, Germany; (B.F.); (M.B.); (F.S.)
| | - Stefan van Drongelen
- Dr. Rolf M. Schwiete Research Unit for Osteoarthritis, Department of Trauma Surgery and Orthopedics, University Hospital Frankfurt, Goethe University Frankfurt, Marienburgstr. 2, 60528 Frankfurt, Germany
| |
Collapse
|
16
|
García-Rey E, Saldaña L. Spinopelvic interactions in total hip arthroplasty: 295 patients followed for a minimum follow-up of 10 years. Hip Int 2024; 34:487-497. [PMID: 38695378 DOI: 10.1177/11207000241248074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 06/26/2024]
Abstract
BACKGROUND Concurrent spinal pathology is frequent in patients undergoing total hip arthroplasty (THA). In this study we examined whether spinopelvic interactions affect THA outcomes at a minimum follow-up of 10 years. PATIENTS AND METHODS 295 patients with a mean age of 63.3 (range 56‒80) years receiving a THA between 2006 and 2009 were assessed. Of these, 195 had mild lumbar disc degeneration and 100 had advanced lumbar spondylosis. We analysed the changes in the Harris Hip Score (HHS) and the survival rate for postoperative low back pain (LBP) and dislocation. Changes in acetabular component position, sacro-femoral-pubic (SFP) and pelvic obliquity (PO) angles were assessed with radiological images. RESULTS The mean HHS was lower in female patients (p = 0.009), patients >65 years of age (p < 0.001) and those with advanced lumbar spondylosis (p = 0.002). 52 (71.2%) of the patients reporting preoperative LBP experienced improvement after THA while 47 (21.1%) of those without preoperative LBP postoperatively reported new onset LBP. Female patients (p = 0.025; hazard ratio [HR]: 1.831; 95% CI, 1.081-3.101) and those with preoperative LBP (p = 0.007; HR 2.068; 95% CI, 1.221-3.504) were at a higher risk of developing postoperative LBP at 10 years. 4 out of 9 THA dislocations were late and had shown decreasing SFP angle values over time. Acetabular component inclination and anteversion angles increased over time, whereas the SFP angle was associated with sex and age and the PO angle with age and the severity of any preoperative lumbar degeneration. CONCLUSIONS Concurrent spinal pathology influences THA outcomes at a minimum follow-up of 10 years. Sex, age, and associated lumbar degeneration can affect clinical and radiological changes over time. A decrease in SFP angle values over time was found in patients sustaining late dislocation.
Collapse
Affiliation(s)
- Eduardo García-Rey
- Orthopaedics Department, Hospital Universitario La Paz-IdiPAZ, Madrid, Spain
- Biomedical Research Networking Center-Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Madrid, Spain
| | - Laura Saldaña
- Biomedical Research Networking Center-Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Madrid, Spain
- Bone Pathophysiology and Biomaterials Group, Hospital Universitario La Paz-IdiPAZ, Madrid, Spain
| |
Collapse
|
17
|
Scanlon CM, Christensen T, Bieganowski T, Buehring W, Meftah M, Hepinstall MS. "Stuck in the middle": the missing lumbosacral link in total hip arthroplasty. Hip Int 2024; 34:482-486. [PMID: 38469810 DOI: 10.1177/11207000231223706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/13/2024]
Abstract
INTRODUCTION Spinopelvic mobility drives functional acetabular position, influencing dislocation risk after total hip arthroplasty (THA). Patients have been described as "stuck sitting" or "stuck standing" based on pelvic tilt (PT). We hypothesised that some patients are "stuck in the middle," meaning their PT changes minimally from sitting to standing - increasing their risk of dislocation. METHODS We reviewed 195 patients with standing and sitting whole body radiographs prior to THA. Standing anterior pelvic plane tilt (APPT) and standing and sitting sacral slope (SS) were measured and used to calculate sitting APPT. Normal standing and sitting were defined as APPT >-10° and <-20°, respectively. Spinal stiffness was classified as <10° change in sacral slope between sitting and standing. Patients were categorised as: (A) able to fully sit and stand; (B) "stuck sitting" - able to fully sit; unable to fully stand; (C) "stuck standing" - able to fully stand; unable to fully sit; or (D) "stuck in the middle" - unable to sit or stand fully. RESULTS 84 patients could sit and stand normally (A), 22 patients were stuck sitting (B), 76 patients were stuck standing (C), and 13 patients were stuck in the middle (D). While 111 patients (56.9%) were considered stuck, only 58 patients (29.7%) met criteria for spinal stiffness. DISCUSSION We identified a subset of patients with stiff spines and abnormal PT in both sitting and standing, including 37.1% of patients who would be classified as "stuck sitting" based only on standing radiographs. Placing acetabular components in less than anatomic anteversion in these patients may increase posterior dislocation risk.
Collapse
Affiliation(s)
| | - Thomas Christensen
- Department of Orthopaedic Surgery, NYU Langone Health, New York, NY, USA
| | - Thomas Bieganowski
- Department of Orthopaedic Surgery, NYU Langone Health, New York, NY, USA
| | - Weston Buehring
- Department of Orthopaedic Surgery, NYU Langone Health, New York, NY, USA
| | - Morteza Meftah
- Department of Orthopaedic Surgery, NYU Langone Health, New York, NY, USA
| | | |
Collapse
|
18
|
Łaziński M, Niemyjski W, Niemyjski M, Olewnik Ł, Drobniewski M, Synder M, Borowski A. Mobility of the lumbo-pelvic-hip complex (spinopelvic mobility) and sagittal spinal alignment - implications for surgeons performing hip arthroplasty. Arch Orthop Trauma Surg 2024; 144:1945-1953. [PMID: 38554202 DOI: 10.1007/s00402-024-05241-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Accepted: 02/17/2024] [Indexed: 04/01/2024]
Abstract
INTRODUCTION The optimal positioning of the hip prosthesis components is influenced by the mobility and balance of the spine. The present study classifies patients with pathology of the spino-pelvic-hip complex, showing possible methods of preventing hip dislocations after arthroplasty. HYPOTHESIS Hip-Spine Classification helps arthroplasty surgeons to implant components in more patient-specific position. MATERIALS AND METHODS The group of 100 patients treated with total hip arthroplasty. Antero-posterior (AP) X-rays of the pelvis in a standing position, lateral spine (standing and sitting) and AP of the pelvis (supine after the procedure) were analyzed. We analyzed a change in sacral tilt value when changing from standing to sitting (∆SS), Pelvic Incidence (PI), Lumbar Lordosis (LL) Mismatch, sagittal lumbar pelvic balance (standing position). Patients were classified according to the Hip-Spine Classification. Postoperatively, the inclination and anteversion of the implanted acetabular component were measured. RESULTS In our study 1 A was diagnosed in 61% of all cases, 1B in 18%, 2 A in 16%, 2B in 5%. 50 out of 61 (82%) in group 1 A were placed within the Levinnek "safe zone". In 1B, 2 A, 2B, the position of the acetabular component was influenced by both the spinopelvic mobility and sagittal spinal balance. The mean inclination was 43.35° and the anteversion was 17.4°. CONCLUSIONS Categorizing patients according to Hip-Spine Classification one can identify possible consequences the patients at risk. Pathology of the spino-pelvic-hipcomplex can lead to destabilization or dislocation of hip after surgery even though implanted according to Lewinnek's indications. Our findings suggest that Lewinnek safe zone should be abandoned in favor of the concept of functional safe zones.
Collapse
Affiliation(s)
- Mariusz Łaziński
- Szpital Wojewódzki im. Jana Pawła II w Bełchatowie, Oddział Chirurgii Urazowo- Ortopedycznej, Bełchatów, Poland
- Clinic of Orthopedics and Pediatric Orthopedics, Medical University of Lodz, 92-213 Lodz, ul. Pomorska 251, Lodz, Poland
| | - Włodzimierz Niemyjski
- Szpital Wojewódzki im. Jana Pawła II w Bełchatowie, Oddział Chirurgii Urazowo- Ortopedycznej, Bełchatów, Poland
| | - Michał Niemyjski
- Szpital Wojewódzki im. Jana Pawła II w Bełchatowie, Oddział Chirurgii Urazowo- Ortopedycznej, Bełchatów, Poland
| | - Łukasz Olewnik
- Department of Anatomical Dissection and Donation, Medical University of Lodz, Lodz, Poland
| | - Marek Drobniewski
- Clinic of Orthopedics and Pediatric Orthopedics, Medical University of Lodz, 92-213 Lodz, ul. Pomorska 251, Lodz, Poland
| | - Marek Synder
- Clinic of Orthopedics and Pediatric Orthopedics, Medical University of Lodz, 92-213 Lodz, ul. Pomorska 251, Lodz, Poland
| | - Andrzej Borowski
- Clinic of Orthopedics and Pediatric Orthopedics, Medical University of Lodz, 92-213 Lodz, ul. Pomorska 251, Lodz, Poland.
| |
Collapse
|
19
|
Di Martino A, Geraci G, Brunello M, D'Agostino C, Davico G, Curreli C, Traina F, Faldini C. Hip-spine relationship: clinical evidence and biomechanical issues. Arch Orthop Trauma Surg 2024; 144:1821-1833. [PMID: 38472450 PMCID: PMC10965652 DOI: 10.1007/s00402-024-05227-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Accepted: 02/15/2024] [Indexed: 03/14/2024]
Abstract
The hip-spine relationship is a critical consideration in total hip arthroplasty (THA) procedures. While THA is generally successful in patient, complications such as instability and dislocation can arise. These issues are significantly influenced by the alignment of implant components and the overall balance of the spine and pelvis, known as spinopelvic balance. Patients with alteration of those parameters, in particular rigid spines, often due to fusion surgery, face a higher risk of THA complications, with an emphasis on complications in instability, impingement and dislocation. For these reasons, over the years, computer modelling and simulation techniques have been developed to support clinicians in the different steps of surgery. The aim of the current review is to present current knowledge on hip-spine relationship to serve as a common platform of discussion among clinicians and engineers. The offered overview aims to update the reader on the main critical aspects of the issue, from both a theoretical and practical perspective, and to be a valuable introductory tool for those approaching this problem for the first time.
Collapse
Affiliation(s)
- Alberto Di Martino
- Ist Orthopaedic Department, IRCCS-Istituto Ortopedico Rizzoli, Via Giulio Cesare Pupilli, 1, 40136, Bologna, Italy.
- Department of Biomedical and Neuromotor Science-DIBINEM, University of Bologna, 40136, Bologna, Italy.
| | - Giuseppe Geraci
- Ist Orthopaedic Department, IRCCS-Istituto Ortopedico Rizzoli, Via Giulio Cesare Pupilli, 1, 40136, Bologna, Italy
- Department of Biomedical and Neuromotor Science-DIBINEM, University of Bologna, 40136, Bologna, Italy
| | - Matteo Brunello
- Ist Orthopaedic Department, IRCCS-Istituto Ortopedico Rizzoli, Via Giulio Cesare Pupilli, 1, 40136, Bologna, Italy
- Department of Biomedical and Neuromotor Science-DIBINEM, University of Bologna, 40136, Bologna, Italy
| | - Claudio D'Agostino
- Ist Orthopaedic Department, IRCCS-Istituto Ortopedico Rizzoli, Via Giulio Cesare Pupilli, 1, 40136, Bologna, Italy
- Department of Biomedical and Neuromotor Science-DIBINEM, University of Bologna, 40136, Bologna, Italy
| | - Giorgio Davico
- Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
- Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Bologna, Italy
| | - Cristina Curreli
- Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Francesco Traina
- Department of Biomedical and Neuromotor Science-DIBINEM, University of Bologna, 40136, Bologna, Italy
- Ortopedia-Traumatologia e Chirurgia Protesica e dei Reimpianti di Anca e di Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Cesare Faldini
- Ist Orthopaedic Department, IRCCS-Istituto Ortopedico Rizzoli, Via Giulio Cesare Pupilli, 1, 40136, Bologna, Italy
- Department of Biomedical and Neuromotor Science-DIBINEM, University of Bologna, 40136, Bologna, Italy
| |
Collapse
|
20
|
Chai Y, Maes V, Boudali AM, Rackel B, Walter WL. Inadequate Annotation and Its Impact on Pelvic Tilt Measurement in Clinical Practice. J Clin Med 2024; 13:1394. [PMID: 38592694 PMCID: PMC10931960 DOI: 10.3390/jcm13051394] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Revised: 02/16/2024] [Accepted: 02/21/2024] [Indexed: 04/10/2024] Open
Abstract
BACKGROUND Accurate pre-surgical templating of the pelvic tilt (PT) angle is essential for hip and spine surgeries, yet the reliability of PT annotations is often compromised by human error, inherent subjectivity, and variations in radiographic quality. This study aims to identify challenges leading to inadequate annotations at a landmark dimension and evaluating their impact on PT. METHODS We retrospectively collected 115 consecutive sagittal radiographs for the measurement of PT based on two definitions: the anterior pelvic plane and a line connecting the femoral head's centre to the sacral plate's midpoint. Five annotators engaged in the measurement, followed by a secondary review to assess the adequacy of the annotations across all the annotators. RESULTS The outcomes indicated that over 60% images had at least one landmark considered inadequate by the majority of the reviewers, with poor image quality, outliers, and unrecognized anomalies being the primary causes. Such inadequacies led to discrepancies in the PT measurements, ranging from -2° to 2°. CONCLUSION This study highlights that landmarks annotated from clear anatomical references were more reliable than those estimated. It also underscores the prevalence of suboptimal annotations in PT measurements, which extends beyond the scope of traditional statistical analysis and could result in significant deviations in individual cases, potentially impacting clinical outcomes.
Collapse
Affiliation(s)
- Yuan Chai
- Sydney Musculoskeletal Health and The Kolling Institute, Northern Clinical School, Faculty of Medicine and Health and the Northern Sydney Local Health District, Sydney, NSW 2006, Australia; (A.M.B.); (W.L.W.)
| | - Vincent Maes
- Department of Orthopaedics and Traumatic Surgery, Royal North Shore Hospital, St. Leonards, NSW 2065, Australia;
| | - A. Mounir Boudali
- Sydney Musculoskeletal Health and The Kolling Institute, Northern Clinical School, Faculty of Medicine and Health and the Northern Sydney Local Health District, Sydney, NSW 2006, Australia; (A.M.B.); (W.L.W.)
| | - Brooke Rackel
- Sydney Medical School, The University of Sydney, Sydney, NSW 2006, Australia;
| | - William L. Walter
- Sydney Musculoskeletal Health and The Kolling Institute, Northern Clinical School, Faculty of Medicine and Health and the Northern Sydney Local Health District, Sydney, NSW 2006, Australia; (A.M.B.); (W.L.W.)
- Department of Orthopaedics and Traumatic Surgery, Royal North Shore Hospital, St. Leonards, NSW 2065, Australia;
| |
Collapse
|
21
|
Giai Via R, Migliorini F, Bosco F, Onorato F, Secco DC, Giustra F, Lavia AD, Giachino M, Massè A. Superior outcomes of total hip arthroplasty without prior lumbar arthrodesis: a systematic review and meta-analysis. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:699-711. [PMID: 37847406 PMCID: PMC10857961 DOI: 10.1007/s00590-023-03761-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Accepted: 10/06/2023] [Indexed: 10/18/2023]
Abstract
PURPOSE The number of patients undergoing total hip arthroplasty (THA) surgery after previous lumbar arthrodesis (LA) is rising. Literature suggests that LA may significantly impact pelvic biomechanics and potentially compromise the success of prosthetic hip replacement. This study aims to evaluate complication rates, dislocation rates, and revision rates in patients with prior LA undergoing THA surgery compared to those undergoing THA surgery without prior LA. METHODS A systematic review and meta-analysis were conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. A PICOS template was developed to ensure a structured approach. The search for relevant studies was performed across five databases, including Pubmed, Scopus, Embase, Medline, and Cochrane. The selected articles were evaluated based on the Levels of Evidence (LoE) criteria. The Coleman Methodology Score (mCMS) was employed to analyze the retrospective studies. This systematic review and meta-analysis were registered in the International Prospective Register of Systematic Reviews (PROSPERO). For the outcomes that allowed for a meta-analysis performed using R software, a p < 0.05 was considered statistically significant. RESULTS The final analysis included seventeen studies comprising a total of 3,139,164 cases of THA. Among these cases, 3,081,137 underwent THA surgery alone, while 58,027 patients underwent THA with a previous LA. The study investigated various factors, including dislocation rates, revision rates, and complication, as well as the surgical approach and type of implant used, for both the THA-only group and the group of patients who underwent THA with prior LA. The analysis revealed a statistically significant difference (p < 0.05) for all variables studied, favoring the group of patients who underwent THA alone without prior LA. CONCLUSIONS This systematic review and meta-analysis demonstrated a statistically significant superiority in all analyzed outcomes for patients who underwent THA-only without prior LA. Specifically, patients with isolated THA implants experienced significantly lower incidences of THA dislocation, wound complications, periprosthetic joint infection, revision, and mechanical complications. LEVEL OF EVIDENCE Level IV.
Collapse
Affiliation(s)
- Riccardo Giai Via
- Centro Traumatologico Ortopedico (CTO), Department of Orthopaedic Surgery, University of Turin, Via Gianfranco Zuretti, 29, 10126, Turin, Italy
| | - Filippo Migliorini
- Department of Orthopaedic, Trauma and Reconstructive Surgery, RWTH University Medical Centre, 52074, Aachen, Germany
- Department of Orthopedics and Trauma Surgery, Academic Hospital of Bolzano (SABES-ASDAA), 39100, Bolzano, Italy
| | - Francesco Bosco
- Centro Traumatologico Ortopedico (CTO), Department of Orthopaedic Surgery, University of Turin, Via Gianfranco Zuretti, 29, 10126, Turin, Italy.
- Department of Orthopaedics and Traumatology, Ospedale San Giovanni Bosco di Torino - ASL Città di Torino, Turin, Italy.
- Department of Orthopaedics and Traumatology (DiChirOnS), University of Palermo, Palermo, Italy.
| | - Francesco Onorato
- Centro Traumatologico Ortopedico (CTO), Department of Orthopaedic Surgery, University of Turin, Via Gianfranco Zuretti, 29, 10126, Turin, Italy
| | - Davide Carlo Secco
- Centro Traumatologico Ortopedico (CTO), Department of Orthopaedic Surgery, University of Turin, Via Gianfranco Zuretti, 29, 10126, Turin, Italy
| | - Fortunato Giustra
- Centro Traumatologico Ortopedico (CTO), Department of Orthopaedic Surgery, University of Turin, Via Gianfranco Zuretti, 29, 10126, Turin, Italy
- Department of Orthopaedics and Traumatology, Ospedale San Giovanni Bosco di Torino - ASL Città di Torino, Turin, Italy
| | | | - Matteo Giachino
- Centro Traumatologico Ortopedico (CTO), Department of Orthopaedic Surgery, University of Turin, Via Gianfranco Zuretti, 29, 10126, Turin, Italy
| | - Alessandro Massè
- Centro Traumatologico Ortopedico (CTO), Department of Orthopaedic Surgery, University of Turin, Via Gianfranco Zuretti, 29, 10126, Turin, Italy
| |
Collapse
|
22
|
Stegelmann SD, Butler JT, Hiatt JL, Bullock MW. Safe Sex After Total Hip Arthroplasty: Using Computed Tomography-Based Robotics to Evaluate "At-Risk" Sexual Positions. J Arthroplasty 2024; 39:433-440.e4. [PMID: 37572725 DOI: 10.1016/j.arth.2023.08.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 08/04/2023] [Accepted: 08/05/2023] [Indexed: 08/14/2023] Open
Abstract
BACKGROUND Total hip arthroplasty (THA) can improve sexual satisfaction, but fear of dislocation can lead to sexual difficulties following this procedure. Previous kinematic research identified 4 sexual positions in women and 2 in men that were considered at risk for impingement. This study aimed to validate these findings using current robotic THA simulations. METHODS The 3-dimensional renderings from 12 patients who received computed tomography (CT)-based robotic THA were used to assess for prosthetic and/or bony impingement among 12 popular sexual positions. There were 9 cup orientations tested for each position (a combination of anteversion [0 °, 15 °, and 30 °] and inclination [40 °, 45 °, and 60 °]). The at-risk positions were tested again using the unique hip positions and cup orientations where previous geometric modeling data found impingement to occur. RESULTS Using mean hip positions, impingement occurred in at least 1 patient in 1 of the 12 positions for women (position 5) and 5 of the 12 positions for men (positions 1, 5, 8, 10, and 11). Among the at-risk positions, impingement occurred in none of the 2 at-risk women positions (0 of 17 cup orientations) and in both at-risk men positions (9 of 9 cup orientations for position 8 and 1 of 1 for position 11). CONCLUSION Recreating popular and at-risk sexual positions following THA with a CT-based robotics system yielded results that were inconsistent with previous geometric modeling data. Resolving these discrepancies is crucial for surgeons to provide accurate postoperative patient education. The CT-based robotic systems may provide necessary input to feasibly individualize such recommendations, but current limitations in CT-based robotics require continued attention and innovation.
Collapse
Affiliation(s)
| | - Justin T Butler
- Department of Orthopedic Surgery, Mercy Health Saint Vincent Medical Center, Toledo, Ohio
| | - John L Hiatt
- Department of Orthopedic Surgery, Mercy Health Saint Vincent Medical Center, Toledo, Ohio
| | - Matthew W Bullock
- Department of Orthopaedic Surgery, Marshall University, Joan C. Edwards School of Medicine, Huntington, West Virginia
| |
Collapse
|
23
|
Zgouridou A, Kenanidis E, Potoupnis M, Tsiridis E. Global mapping of institutional and hospital-based (Level II-IV) arthroplasty registries: a scoping review. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY : ORTHOPEDIE TRAUMATOLOGIE 2024; 34:1219-1251. [PMID: 37768398 PMCID: PMC10858160 DOI: 10.1007/s00590-023-03691-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 08/13/2023] [Indexed: 09/29/2023]
Abstract
PURPOSE Four joint arthroplasty registries (JARs) levels exist based on the recorded data type. Level I JARs are national registries that record primary data. Hospital or institutional JARs (Level II-IV) document further data (patient-reported outcomes, demographic, radiographic). A worldwide list of Level II-IV JARs must be created to effectively assess and categorize these data. METHODS Our study is a systematic scoping review that followed the PRISMA guidelines and included 648 studies. Based on their publications, the study aimed to map the existing Level II-IV JARs worldwide. The secondary aim was to record their lifetime, publications' number and frequency and recognise differences with national JARs. RESULTS One hundred five Level II-IV JARs were identified. Forty-eight hospital-based, 45 institutional, and 12 regional JARs. Fifty JARs were found in America, 39 in Europe, nine in Asia, six in Oceania and one in Africa. They have published 485 cohorts, 91 case-series, 49 case-control, nine cross-sectional studies, eight registry protocols and six randomized trials. Most cohort studies were retrospective. Twenty-three per cent of papers studied patient-reported outcomes, 21.45% surgical complications, 13.73% postoperative clinical and 5.25% radiographic outcomes, and 11.88% were survival analyses. Forty-four JARs have published only one paper. Level I JARs primarily publish implant revision risk annual reports, while Level IV JARs collect comprehensive data to conduct retrospective cohort studies. CONCLUSIONS This is the first study mapping all Level II-IV JARs worldwide. Most JARs are found in Europe and America, reporting on retrospective cohorts, but only a few report on studies systematically.
Collapse
Affiliation(s)
- Aikaterini Zgouridou
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece
| | - Eustathios Kenanidis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece.
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece.
| | - Michael Potoupnis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece
| | - Eleftherios Tsiridis
- Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, 56403, Thessaloniki, Greece
- Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, 57001, Thessaloniki, Greece
| |
Collapse
|
24
|
Stadler C, Feldler S, Stevoska S, Schopper C, Gotterbarm T, Luger M. Gender differences in cementless short stem total hip arthroplasty: significantly higher femoral lengthening in female patients. Sci Rep 2024; 14:1154. [PMID: 38212361 PMCID: PMC10784556 DOI: 10.1038/s41598-024-51621-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Accepted: 01/08/2024] [Indexed: 01/13/2024] Open
Abstract
Modern cementless short stems in total hip arthroplasty (THA) enable a precise reconstruction of the native pre-arthritic hip geometry. While gender differences have been reported for older generation straight hip stems, there are hardly reports regarding modern cementless short hip stems. Therefore, we aimed to evaluate the influence of gender differences in hip anatomy in cementless short stem THA. A total of 207 patients (109 females, 98 males) with unilateral THA and absence of contralateral joint space narrowing (Kellgren-Lawrence grade ≤ 2) were included. Acetabular height and offset as well as femoral height and offset were measured on pre- and 3-months-postoperative anteroposterior X-rays of the pelvis and compared to the contralateral hip. Additionally, implant position was evaluated on the postoperative radiograph. In male patients, the loss of acetabular offset was significantly greater than in females (p = 0.012), leading to a compensatory increase in femoral offset (p = 0.041). Femoral height discrepancy was significantly higher in females (p < 0.001), accounting for an increased global hip height discrepancy (p < 0.001). The mean acetabular anteversion was significantly greater in female patients (p < 0.001). Female patients are at higher risk of femoral lengthening in THA with a cementless short stem potentially caused by a further proximally conducted femoral neck osteotomy and show significantly higher cup anteversion angles. Therefore, surgeons should take special care to the level of neck resection and implant positioning in female patients.
Collapse
Affiliation(s)
- Christian Stadler
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstr. 9, 4020, Linz, Austria.
- Johannes Kepler University Linz, Altenberger Str. 96, 4040, Linz, Austria.
| | - Sandra Feldler
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstr. 9, 4020, Linz, Austria
- Johannes Kepler University Linz, Altenberger Str. 96, 4040, Linz, Austria
| | - Stella Stevoska
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstr. 9, 4020, Linz, Austria
- Johannes Kepler University Linz, Altenberger Str. 96, 4040, Linz, Austria
| | - Clemens Schopper
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstr. 9, 4020, Linz, Austria
- Johannes Kepler University Linz, Altenberger Str. 96, 4040, Linz, Austria
| | - Tobias Gotterbarm
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstr. 9, 4020, Linz, Austria
- Johannes Kepler University Linz, Altenberger Str. 96, 4040, Linz, Austria
| | - Matthias Luger
- Department for Orthopaedics and Traumatology, Kepler University Hospital GmbH, Med Campus III, Krankenhausstr. 9, 4020, Linz, Austria
- Johannes Kepler University Linz, Altenberger Str. 96, 4040, Linz, Austria
| |
Collapse
|
25
|
Shah HN, Barrett AA, Finlay AK, Arora P, Bellino MJ, Bishop JA, Gardner MJ, Miller MD, Huddleston JI, Maloney WJ, Goodman SB, Amanatullah DF. Arthroplasty for femoral neck fractures is at risk for under restoration of lateral femoral offset. Hip Int 2024; 34:134-143. [PMID: 37128124 DOI: 10.1177/11207000231169914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
PURPOSE The aim of the study was to determine the restoration of hip biomechanics through lateral offset, leg length, and acetabular component position when comparing non-arthroplasty surgeons (NAS) to elective arthroplasty surgeons (EAS). METHODS 131 patients, with a femoral neck fracture treated with a THA by 7 EAS and 20 NAS, were retrospectively reviewed. 2 blinded observers measured leg-length discrepancy, femoral offset, and acetabular component position. Multivariate logistic regression models examined the association between the surgeon groups and restoration of lateral femoral, acetabular offset, leg length discrepancy, acetabular anteversion, acetabular position, and component size, while adjusting for surgical approach and spinal pathology. RESULTS NAS under-restored 4.8 mm of lateral femoral offset (43.9 ± 8.7 mm) after THA when compared to the uninjured side (48.7 ± 7.1 mm, p = 0.044). NAS were at risk for under-restoring lateral femoral offset when compared to EAS (p = 0.040). There was no association between lateral acetabular offset, leg length, acetabular position, or component size and surgeon type. CONCLUSIONS Lateral femoral offset is at risk for under-restoration after THA for femoral neck fractures, when performed by surgeons that do not regularly perform elective THA. This indicates that lateral femoral offset is an under-appreciated contributor to hip instability when performing THA for a femoral neck fracture. Lateral femoral offset deserves as much attention and awareness as acetabular component position since a secondary analysis of our data reveal that preoperative templating and intraoperative imaging did not prevent under-restoration.
Collapse
Affiliation(s)
- Harsh N Shah
- Department of Orthopaedic Surgery, Stanford Medicine, Redwood City, CA, USA
| | - Andrew A Barrett
- Department of Orthopaedic Surgery, Stanford Medicine, Redwood City, CA, USA
| | - Andrea K Finlay
- Department of Orthopaedic Surgery, Stanford Medicine, Redwood City, CA, USA
| | - Prerna Arora
- Department of Orthopaedic Surgery, Stanford Medicine, Redwood City, CA, USA
| | - Michael J Bellino
- Department of Orthopaedic Surgery, Stanford Medicine, Redwood City, CA, USA
| | - Julius A Bishop
- Department of Orthopaedic Surgery, Stanford Medicine, Redwood City, CA, USA
| | - Michael J Gardner
- Department of Orthopaedic Surgery, Stanford Medicine, Redwood City, CA, USA
| | - Matthew D Miller
- Department of Orthopaedic Surgery, Stanford Medicine, Redwood City, CA, USA
| | - James I Huddleston
- Department of Orthopaedic Surgery, Stanford Medicine, Redwood City, CA, USA
| | - William J Maloney
- Department of Orthopaedic Surgery, Stanford Medicine, Redwood City, CA, USA
| | - Stuart B Goodman
- Department of Orthopaedic Surgery, Stanford Medicine, Redwood City, CA, USA
| | | |
Collapse
|
26
|
Pangaud C, Pioger C, Pauly V, Orleans V, Boyer L, Argenson JN, Ollivier M. Response to letter from Sheng Zhao, Yuanmin Zhang, Caining Wen. Orthop Traumatol Surg Res 2023; 109:103667. [PMID: 37506836 DOI: 10.1016/j.otsr.2023.103667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Accepted: 07/20/2023] [Indexed: 07/30/2023]
Affiliation(s)
- Corentin Pangaud
- Institute of Movement and Locomotion UMR 7287, Aix-Marseille université et CNRS, 270, boulevard Saint-Marguerite, 13009 Marseille, France; Public Hospital of Marseille, 80, rue Brochier, 13005 Marseille, France.
| | - Charles Pioger
- Public Hospital of Paris, hôpital Ambroise-Paré, 9, avenue Charles-de-Gaulles, 92100 Boulogne-Billancourt, France
| | - Vanessa Pauly
- Public Health Department, Public Hospital of Marseille, hôpital de la Conception, 147, boulevard Baille, 13005 Marseille, France
| | - Veronica Orleans
- Public Health Department, Public Hospital of Marseille, hôpital de la Conception, 147, boulevard Baille, 13005 Marseille, France
| | - Laurent Boyer
- Public Health Department, Public Hospital of Marseille, hôpital de la Conception, 147, boulevard Baille, 13005 Marseille, France
| | - Jean-Noël Argenson
- Institute of Movement and Locomotion UMR 7287, Aix-Marseille université et CNRS, 270, boulevard Saint-Marguerite, 13009 Marseille, France; Public Hospital of Marseille, 80, rue Brochier, 13005 Marseille, France
| | - Matthieu Ollivier
- Institute of Movement and Locomotion UMR 7287, Aix-Marseille université et CNRS, 270, boulevard Saint-Marguerite, 13009 Marseille, France; Public Hospital of Marseille, 80, rue Brochier, 13005 Marseille, France
| |
Collapse
|
27
|
Hao L, Zhang Y, Bian W, Song W, Li K, Wang N, Wen P, Ma T. Standardized 3D-printed trabecular titanium augment and cup for acetabular bone defects in revision hip arthroplasty: a mid-term follow-up study. J Orthop Surg Res 2023; 18:521. [PMID: 37481549 PMCID: PMC10362760 DOI: 10.1186/s13018-023-03986-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/27/2022] [Accepted: 07/07/2023] [Indexed: 07/24/2023] Open
Abstract
BACKGROUND The aim of this study was to assess the feasibility and outcomes of standardized three-dimensional (3D)-printed trabecular titanium (TT) cups and augments to reconstruct most acetabular defects. METHODS We included 58 patients with Paprosky type II and III acetabular bone defects who underwent revision hip arthroplasty between 2015 and 2018. Patients who were revised without 3D-printed augments, and cases who were lost to follow-up and died during follow-up were excluded. Radiographic and clinical outcomes were evaluated. A Kaplan-Meier survivorship curve was generated. The mean follow-up was 64.5 (range 49-84) months. RESULTS In total, 48 (82.8%) acetabular revisions were performed using standardized 3D-printed TT cups and augments, and a retrospective review was conducted on 43 revisions. The average position of the vertical center of rotation and leg length discrepancy were significantly decreased from 42.4 ± 9.1 mm and 38.4 ± 10.7 mm to 22.8 ± 3.4 mm and 4.1 ± 3.0 mm, respectively. Non-progressive radiolucent lines were observed in 3 (7.5%) acetabular components with no indications for revision. The mean Harris hip score, Oxford hip score and EuroQol five-dimensional questionnaire score increased from 33.0 ± 10.7, 11.4 ± 3.4 and 0.29 ± 0.09 to 80.3 ± 8.8, 35.8 ± 2.4 and 0.71 ± 0.10, respectively. The revision-free survival rate of the acetabular component was 93.0% (40/43), with a rate of revision for aseptic loosening of 2.3% (1/43). CONCLUSION Standardized 3D‑printed TT augments and cups could be used to reconstruct the majority of Paprosky type II and III acetabular defects in revision hip arthroplasty and demonstrated encouraging results at mid-term follow-up.
Collapse
Affiliation(s)
- Linjie Hao
- Department of Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, No. 555 Youyi East Road, Xi'an, 710000, Shaanxi, China
- Department of Orthopedics, The First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, 710061, Shaanxi, China
| | - Yumin Zhang
- Department of Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, No. 555 Youyi East Road, Xi'an, 710000, Shaanxi, China
| | - Weiguo Bian
- Department of Orthopedics, The First Affiliated Hospital of Xi'an Jiaotong University, 277 West Yanta Road, Xi'an, 710061, Shaanxi, China
| | - Wei Song
- Department of Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, No. 555 Youyi East Road, Xi'an, 710000, Shaanxi, China
| | - Kun Li
- Department of Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, No. 555 Youyi East Road, Xi'an, 710000, Shaanxi, China
| | - Nengjun Wang
- Department of Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, No. 555 Youyi East Road, Xi'an, 710000, Shaanxi, China
| | - Pengfei Wen
- Department of Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, No. 555 Youyi East Road, Xi'an, 710000, Shaanxi, China.
| | - Tao Ma
- Department of Joint Surgery, Honghui Hospital, Xi'an Jiaotong University, No. 555 Youyi East Road, Xi'an, 710000, Shaanxi, China.
| |
Collapse
|
28
|
Bradley MP, Muir JM, Wang S. Computer-Assisted Navigation Accurately Delivers Preoperative Targets for Acetabular Component Orientation During Direct Anterior Approach Total Hip Arthroplasty. Orthopedics 2023; 46:218-223. [PMID: 36719422 DOI: 10.3928/01477447-20230125-03] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Despite its success, total hip arthroplasty (THA) remains associated with potentially significant complications associated with component malposition. Preoperative planning can mitigate some of these potential concerns; however, the accurate intraoperative delivery of preoperative targets can be challenging. Computer-assisted navigation may assist with intraoperative target delivery, although the integration of these two technologies is relatively uncommon. We retrospectively reviewed cases of THA planned with a computed tomography-based preoperative planning software and performed with the use of an imageless, computer-assisted navigation system. Postoperative acetabular component orientation from radiographs was compared with preoperative targets and intraoperative navigation measurements. A total of 76 patients were included in the analysis. The mean anteversion target (20.0°±3.1°) did not differ significantly from the mean intraoperative navigation measurement (20.5°±3.3°; P=.30; mean difference, 2.2°±2.3°). The mean radiographic measurement (26.6°±6.5°) differed from the target by a mean of 7.5°±6.1° (P<.001). The mean inclination target (38.4°±1.9°) did not differ significantly from the mean intra-operative measurement (38.0°±1.5°; P=.20; mean difference, 1.3°±1.7°) but differed from the radiographic measurement by a mean of 5.2°±4.2° (41.8°±5.6°; P<.001). No adverse events were reported in the 90-day period following the index procedure. Our study demonstrated that an imageless navigation system can accurately deliver computed tomography-derived preoperative targets for acetabular component orientation. Differences noted on radiographs may be due to the difference in patient positioning for the postoperative imaging (standing) as compared with preoperative imaging or surgery itself (supine). [Orthopedics. 2023;46(4):218-223.].
Collapse
|
29
|
Lu H, Zhu N, Ling T, Cao J, Xu H, Zhou K, Zhao E, Zhou Z. Total hip arthroplasty for failed internal fixation of femoral neck fracture: a retrospective study with 2-14 years' follow-up of 345 patients. J Orthop Surg Res 2023; 18:341. [PMID: 37161494 PMCID: PMC10169472 DOI: 10.1186/s13018-023-03827-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Accepted: 05/04/2023] [Indexed: 05/11/2023] Open
Abstract
OBJECTIVES The purpose of this study was to analyze mid- to long-term outcomes of total hip arthroplasty (THA) following failed internal fixation of femoral neck fracture. METHODS This study retrospectively analyzed 345 patients with femoral neck fracture who underwent THA after failure of internal fixation at our hospital between January, 2003 and December, 2019. Patients older than 55 years (n = 175) and patients no older than 55 years (n = 170) were compared in terms of complications and survival rates during follow-up, which lasted a mean of 6 years. RESULTS The two age groups showed similarly low incidence of complications and similarly long periods of survival without revision surgery. Only three younger patients and two older patients underwent revision surgery during follow-up. The two groups showed similarly high survival rates at the end of follow-up (> 93%). Younger patients showed significantly bettter Harris hip score at last follow-up (90.2 vs. 88.1 points, p < 0.001) without clinically significant difference, but they required THA significantly earlier after internal fixation (4.4 vs. 6.8 years, p < 0.001). CONCLUSIONS THA after failed internal fixation of femoral neck fracture is a well tolerated and effective procedure in older and younger patients.
Collapse
Affiliation(s)
- Hanpeng Lu
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University, No.37, Guoxue Road, Wuhou District, Chengdu, 610041, Sichuan, People's Republic of China
| | - Niu Zhu
- Precision Medicine Center, West China Hospital, Sichuan University, No.37, Guoxue Road, Wuhou District, Chengdu, 610041, Sichuan, People's Republic of China
| | - Tingxian Ling
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University, No.37, Guoxue Road, Wuhou District, Chengdu, 610041, Sichuan, People's Republic of China
| | - Jian Cao
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University, No.37, Guoxue Road, Wuhou District, Chengdu, 610041, Sichuan, People's Republic of China
| | - Hong Xu
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University, No.37, Guoxue Road, Wuhou District, Chengdu, 610041, Sichuan, People's Republic of China
| | - Kai Zhou
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University, No.37, Guoxue Road, Wuhou District, Chengdu, 610041, Sichuan, People's Republic of China
| | - Enze Zhao
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University, No.37, Guoxue Road, Wuhou District, Chengdu, 610041, Sichuan, People's Republic of China
| | - Zongke Zhou
- Department of Orthopaedic Surgery, West China Hospital, Sichuan University, No.37, Guoxue Road, Wuhou District, Chengdu, 610041, Sichuan, People's Republic of China.
| |
Collapse
|
30
|
Xie R, Huang J, Wu Q, Qian Y, Jiang D, Li L, Huang L. A Comparison of Radiographic Outcomes after Total Hip Arthroplasty between the Direct Lateral Approach and Posterior Lateral Approach with EOS 2D/3D X-Ray Imaging System. Orthop Surg 2023; 15:1312-1324. [PMID: 37076774 PMCID: PMC10157717 DOI: 10.1111/os.13726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2022] [Revised: 03/10/2023] [Accepted: 03/14/2023] [Indexed: 04/21/2023] Open
Abstract
OBJECTIVE The classical approaches for total hip arthroplasty (THA) are the direct lateral approach (DLA) and posterior lateral approach (PLA). There are few studies comparing implant orientation with these two approaches, and the impact of surgical approaches on implant orientation remains controversial. With the rise of the EOS imaging system, we aimed to use it to identify the differences between and factors associated with implant orientation after THA using DLA and PLA. METHODS In our department from January 2019 to December 2021, 321 primary unilateral THAs that used PLA and DLA were enrolled. A total of 201 patients who received PLA and 120 patients who received DLA were included in this study. Two blinded observers measured each case using EOS imaging data. Postoperative imaging metrics and other relevant influencing factors of the two surgical approaches were compared. Postoperative imaging metrics, including the anteversion and inclination of the cup, anteversion of the stem, and combined anteversion were measured based on EOS. Other relevant influencing factors included age, approach, gender, laterality, BMI, anterior pelvic plane inclination, femoral head diameter, femoral offset, lateral pelvic tilt, pelvic incidence, pelvis axial rotation, sacral slope, sagittal pelvic tilt, and surgery time. Multiple linear regression analyses were performed to identify the predictors of acceptability for each imaging data point. RESULTS No dislocation was found in the 321 patients who underwent primary THA during this period. The mean anteversion and combined anteversion of the cups using the DLA were 21.33° ± 17.31° (-51.7°-60.8°) and 33.71° ± 20.85° (-38.8°-77.6°) and PLA were 25.34° ± 12.76° (-5.5°-57.0°) and 42.37° ± 18.85° (-8.7°-84.7°), respectively. The DLA group had smaller anteversion (p = 0.038) and combined anteversion (p < 0.001). We found that surgical approach (p < 0.05), anterior pelvic plane inclination (p < 0.001), gender (p < 0.001), and femoral head diameter (p < 0.001) were important factors affecting acetabular cup anteversion (R2 = 0.375) and combined anteversion (R2 = 0.525). CONCLUSIONS In total hip arthroplasty, different prosthesis installation directions should be made according to different surgical approaches. Compared with the direct lateral approach, the acetabular anteversion can be intentionally enlarged when using the posterolateral approach. Surgical approach, anterior pelvic plane inclination (APPI), gender, and femoral head diameter were significant predictors of prosthesis orientation. The anterior pelvic plane inclination may be a useful standard for assessing the position of the prosthesis using EOS.
Collapse
Affiliation(s)
- Rui Xie
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| | - Jun Huang
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| | - Qian Wu
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| | - Yu‐fan Qian
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| | - Dinghua Jiang
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| | - Lisong Li
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| | - Lixin Huang
- Department of Orthopaedic SurgeryThe First Affiliated Hospital of Soochow UniversitySuzhouChina
| |
Collapse
|
31
|
Dennis DA, Smith GH, Phillips J, Ennis H, Jennings JM, Plaskos C, Pierrepont JW. Does Individualization of Cup Position Affect Prosthetic or Bone Impingement Following THA? J Arthroplasty 2023:S0883-5403(23)00387-X. [PMID: 37100096 DOI: 10.1016/j.arth.2023.04.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 04/11/2023] [Accepted: 04/12/2023] [Indexed: 04/28/2023] Open
Abstract
INTRODUCTION Spinopelvic (SP) mobility patterns during postural changes affect three-dimensional acetabular component position, the incidence of prosthetic impingement, and total hip arthroplasty (THA) instability. Surgeons have commonly placed the acetabular component in a similar "safe zone" for most patients. Our purpose was to determine the incidence of bone and prosthetic impingement with various cup orientations and determine if a preoperative SP analysis with individualized cup orientation lessens impingement. METHODS A preoperative SP evaluation of 78 THA subjects was performed. Data was analyzed using a software program to determine the prevalence of prosthetic and bone impingement with a patient individualized cup orientation versus six commonly selected cup orientations. Impingement was correlated with known SP risk factors for dislocation. RESULTS Prosthetic impingement was least with the individualized choice of cup position (9%) vs. preselected cup positions (18 to 61%). The presence of bone impingement (33%) was similar in all groups and not affected by cup position. Factors associated with impingement in flexion were age, lumbar flexion, pelvic tilt (stand to flexed seated), and functional femoral stem anteversion. Risk factors in extension included standing pelvic tilt, standing SP tilt, lumbar flexion, pelvic rotation (supine to stand and stand to flexed seated), and functional femoral stem anteversion. CONCLUSION Prosthetic impingement is reduced with individualized cup positioning based on SP mobility patterns. Bone impingement occurred in one-third of patients and is a noteworthy consideration in preoperative THA planning. Known SP risk factors for THA instability correlated with the It dependspresence of prosthetic impingement in both flexion and extension.
Collapse
Affiliation(s)
- Douglas A Dennis
- Colorado Joint Replacement, Denver, CO, USA; Department of Mechanical and Materials Engineering, University of Denver, Denver, CO; Department of Orthopaedics, University of Colorado School of Medicine, Denver, CO; Department of Biomedical Engineering, University of Tennessee, Knoxville, TN.
| | - Gerard H Smith
- Corin Group, Cirencester, Gloucestershire, United Kingdom
| | | | | | - Jason M Jennings
- Colorado Joint Replacement, Denver, CO, USA; Department of Mechanical and Materials Engineering, University of Denver, Denver, CO
| | | | | |
Collapse
|
32
|
Anderson CG, Jang SJ, Brilliant ZR, Mayman DJ, Vigdorchik JM, Jerabek SA, Sculco PK. Complication Rate after Primary Total Hip Arthroplasty Using the Posterior Approach and Enabling Technology: A Consecutive Series of 2,888 Hips. J Arthroplasty 2023:S0883-5403(23)00384-4. [PMID: 37088223 DOI: 10.1016/j.arth.2023.04.029] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Revised: 04/16/2023] [Accepted: 04/17/2023] [Indexed: 04/25/2023] Open
Abstract
BACKGROUND Total hip arthroplasty (THA) is a safe and effective procedure, however, complications such as dislocation, fracture, and infection still occur. It is still unclear whether the dislocation rate via the posterior approach (PA) is better, equal, or worse than the direct anterior approach. Our aim was to report the primary THA dislocation rate via the PA using enabling technology in a large consecutive series of patients. METHODS A retrospective cohort of 2,888 primary THAs were reviewed at a single, high volume, academic institution from January 2018 to September 2021. All patients underwent a THA by four fellowship-trained orthopaedic surgeons through the PA with enabling technology. Overall dislocation and readmission rates within 90 days and up to 3 years were analyzed. RESULTS Of the 2,888 procedures, a total of 39 patients had complications related to the surgery during the 3-year follow-up period. There were 10 patients (0.35%) who experienced a dislocation, with half undergoing surgical revision. Of the 39 patients who experienced complications, 37 (1.3%) were readmitted and 2 underwent revision during their hospital stay. Post-operative periprosthetic fractures were the most common cause for readmission and reoperation at a rate of 0.52 and 0.52%, respectively. CONCLUSION The dislocation rate of 0.35% is one of the lowest reported rates via the PA at a mean follow up of 2.1 years and is comparable to previously published rates using alternate approaches. Using contemporary THA with enabling technology, the PA is a reliable approach with respect to dislocation and complication rates after primary THA.
Collapse
|
33
|
Carroll JD, Young JR, Mori BV, Gheewala R, Lakra A, DiCaprio MR. Total Hip and Knee Arthroplasty Surgery in the Morbidly Obese Patient: A Critical Analysis Review. JBJS Rev 2023; 11:01874474-202304000-00007. [PMID: 37098128 DOI: 10.2106/jbjs.rvw.22.00177] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/27/2023]
Abstract
» Obesity, defined as body mass index (BMI) ≥30, is a serious public health concern associated with an increased incidence of stroke, diabetes, mental illness, and cardiovascular disease resulting in numerous preventable deaths yearly. » From 1999 through 2018, the age-adjusted prevalence of morbid obesity (BMI ≥40) in US adults aged 20 years and older has risen steadily from 4.7% to 9.2%, with other estimates showing that most of the patients undergoing hip and knee replacement by 2029 will be obese (BMI ≥30) or morbidly obese (BMI ≥40). » In patients undergoing total joint arthroplasty (TJA), morbid obesity (BMI ≥40) is associated with an increased risk of perioperative complications, including prosthetic joint infection and mechanical failure necessitating aseptic revision. » The current literature on the role that bariatric weight loss surgery before TJA has on improving surgical outcomes is split and referral to a bariatric surgeon should be a shared-decision between patient and surgeon on a case-by-case basis. » Despite the increased risk profile of TJA in the morbidly obese cohort, these patients consistently show improvement in pain and physical function postoperatively that should be considered when deciding for or against surgery.
Collapse
Affiliation(s)
- Jeremy D Carroll
- Division of Orthopaedic Surgery, Albany Medical Center, Albany, New York
| | | | | | | | | | | |
Collapse
|
34
|
Langer S, Stephan M, von Eisenhart-Rothe R. Importance of Hip-Spine Syndrome in Hip Arthroplasty: Influence on the Outcome and Therapeutic Consequences. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2023; 161:168-174. [PMID: 34544166 DOI: 10.1055/a-1527-7697] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Correct interaction between the spine, pelvis, and hip is an essential condition for successful progress after total hip replacement. Spinal pathologies, such as degeneration, fractures, and spinopelvic imbalance with and without lumbar fusions, are closely associated with an increased risk of impingement or even dislocation of the prosthesis. To significantly reduce this risk, various parameters are required to quantify the risk groups. Knowledge on the presence of stiffness of the spine (change in pelvic tilt between standing and sitting at < 10°) and sagittal spinal deformity (pelvic incidence-lumbar lordosis mismatch > 10° or 20°) is essential in identifying patients with corresponding risk. The individual risk profile can be assessed through a specific history and examination. Before total hip arthroplasty, a routine preoperative workup is recommended for high-risk patients: using information from standardised preoperative radiographs while sitting and standing (pelvis, anteroposterior view, lying and standing; spine and pelvis, lateral view, standing and sitting). Important changes can be made during the surgery. If the spine is stiff, attention should be paid to the position of the cup, with increased anteversion, sufficient offset, and larger head that is secure to dislocation - to reduce the risk of dislocation. In the case of a sagittal spinal deformity, the functional coronary pelvic level must be carefully controlled so that it is better to use double mobility cups. Digital systems, such as navigation and robotics, can optimise component positioning although, so far, there is little evidence that the complication rate decreased. Therefore, further studies are warranted.
Collapse
Affiliation(s)
- Severin Langer
- Clinic and Polyclinic for Orthopaedics and Sports Orthopaedics, Klinikum Rechts der Isar of the Technical University of Munich, Germany
| | - Maximilian Stephan
- Clinic and Polyclinic for Orthopaedics and Sports Orthopaedics, Klinikum Rechts der Isar of the Technical University of Munich, Germany
| | - Rüdiger von Eisenhart-Rothe
- Clinic and Polyclinic for Orthopaedics and Sports Orthopaedics, Klinikum Rechts der Isar of the Technical University of Munich, Germany
| |
Collapse
|
35
|
Manouras L, Bastian JD, Beckmann NA, Tosounidis TH. The Top Three Burning Questions in Total Hip Arthroplasty. Medicina (B Aires) 2023; 59:medicina59040655. [PMID: 37109613 PMCID: PMC10142130 DOI: 10.3390/medicina59040655] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2023] [Revised: 03/13/2023] [Accepted: 03/20/2023] [Indexed: 03/29/2023] Open
Abstract
Total hip arthroplasty (THA) for end-stage osteoarthritis is one of the most effective surgical treatments in medicine. Impressive outcomes have been well documented in the literature with patients gaining ambulation and recovery of hip joint function. Nevertheless, there are still debatable issues and controversies that the orthopedic community has not been able to provide a definitive answer for. This review is focused on the current three most debatable issues surrounding the THA procedure: (1) new cutting-edge technology, (2) spinopelvic mobility, and (3) fast-track protocols. The scope of the herein narrative review is to analyze the debatable issues surrounding the three aforementioned topics and conclude the best contemporary clinical approaches regarding each issue.
Collapse
|
36
|
LeBrun DG, Ondeck NT, Nessler JP, Marchand RC, Illgen RL, Westrich GH. Variability of pre-operative functional pelvic tilt in total hip arthroplasty patients. INTERNATIONAL ORTHOPAEDICS 2023; 47:1243-1247. [PMID: 36864185 DOI: 10.1007/s00264-023-05748-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Accepted: 02/22/2023] [Indexed: 03/04/2023]
Abstract
PURPOSE Pelvic tilt (PT) is important to consider when planning total hip arthroplasty (THA) due to its dynamic impact on acetabular orientation. The degree of sagittal pelvic rotation varies during functional activities and can be difficult to measure without proper imaging. The purpose of this study was to evaluate PT variation in the supine, standing, and seated positions. METHODS A multi-centre cross-sectional study was performed that included 358 THA patients who had preo-perative PT measured from supine CT scan and standing and upright seated lateral radiographs. Supine, standing, and seated PT and associated changes between functional positions were evaluated. Anterior PT was assigned a positive value. RESULTS In the supine position, mean PT was 4° (range, -35° to 20°), where 23% had posterior PT and 69% anterior PT. In the standing position, mean PT was 1° (range, -23° to 29°), where 40% had posterior PT and 54% anterior PT. In the seated position, mean PT was -18° (range, -43° to 47°), where 95% had posterior PT and 4% anterior PT. From standing to seated, the pelvis rotated posteriorly in 97% of cases (maximum 60°) with 16% of cases considered stiff (change ≤ 10°) and 18% of cases considered hypermobile (change ≥ 30°). CONCLUSION Patients undergoing THA have marked PT variation in the supine, standing, and seated positions. There was wide variability in PT change from standing to seated, with 16% of patients considered stiff and 18% considered hypermobile. Functional imaging should be performed on patients prior to THA to allow for more accurate planning.
Collapse
Affiliation(s)
- Drake G LeBrun
- Adult Reconstruction Joint Replacement Service, Hospital for Special Surgery, 535 East 70 th Street, New York, NY, 10021, USA.
| | - Nathaniel T Ondeck
- Adult Reconstruction Joint Replacement Service, Hospital for Special Surgery, 535 East 70 th Street, New York, NY, 10021, USA
| | - Joseph P Nessler
- St. Cloud Orthopedics, 1901 Connecticut Ave S, MN, 56377, Sartell, USA
| | - Robert C Marchand
- Ortho Rhode Island, 285 Promenade Street, RI, 02908, Providence, USA
| | - Richard L Illgen
- University of Wisconsin-Madison, 4602 Eastpark Blvd, Madison, WI, 53706, USA
| | - Geoffrey H Westrich
- Adult Reconstruction Joint Replacement Service, Hospital for Special Surgery, 535 East 70 th Street, New York, NY, 10021, USA
| |
Collapse
|
37
|
Roesler K, Garvin KL. Failure of a Highly Cross-Linked Polyethylene Liner After Spine Fusion. J Am Acad Orthop Surg Glob Res Rev 2023; 7:01979360-202303000-00010. [PMID: 36940212 PMCID: PMC10027029 DOI: 10.5435/jaaosglobal-d-22-00150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Accepted: 01/27/2023] [Indexed: 03/21/2023]
Abstract
A 73-year-old woman, 11 years after total hip arthroplasty and 2 years after a multilevel lumbar spine fusion, presented with a 2-month history of anterior hip and gluteal pain. She was diagnosed with an acetabular liner fracture that occurred through the high wall, likely related to repetitive impingement on the neck of the femoral implant, as notable burnishing was observed on the explanted femoral head. The acetabulum was successfully revised to a dual-mobility articulation. Spinal fusion after total hip arthroplasty can alter the acetabular implant position and was seen in our patient whose previously functional high-walled liner failed. Surgeons may consider alternative techniques, including a change in acetabular implant's anteversion to mitigate the need for a high-walled liner or the use of a dual-mobility bearing.
Collapse
Affiliation(s)
- Kimberly Roesler
- From the Creighton University School of Medicine, Omaha, NE (Dr. Roesler), and the Department of Orthopaedic Surgery, University of Nebraska Medical Center, Omaha, NE (Dr. Garvin)
| | | |
Collapse
|
38
|
Relationship between perceived and structural leg length discrepancies of patients with hip osteoarthritis dysplasia. Orthop Traumatol Surg Res 2023; 109:103570. [PMID: 36750154 DOI: 10.1016/j.otsr.2023.103570] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 12/27/2022] [Accepted: 01/09/2023] [Indexed: 02/09/2023]
Abstract
BACKGROUND Only few studies have been conducted on leg length discrepancy (LLD) in patients with hip osteoarthritis (OA). This study aimed to examine the relationship between perceived LLD (pLLD) and structural LLD (sLLD) in patients with advanced OA and to determine the factors influencing both LLDs. This retrospective study aimed to answer the following questions: (1) are older adults less likely to perceive LLD than younger adults? (2) is there a relationship between pLLD and sLLD? and (3) is pLLD associated with patient satisfaction? HYPOTHESIS We hypothesized that older adults are less likely to perceive LLD than younger adults. PATIENTS AND METHODS We recruited 125 patients (102 women and 23 men) with hip OA associated with developmental dysplasia of the hip defined as grade 3 or higher according to the Tönnis classification and excluding contralateral grade 2 or higher. The mean age of the patients was 65.2±11.2 (36-85) years. Before surgery, 2-mm and 5-mm thick plates were placed on the floor on the plantar surface of the short leg to measure pLLD. Preoperative computed tomography (CT) was performed and sLLDs were measured using the 3D planning software ZedHip. The following associated factors were evaluated: age, height, weight, body mass index (BMI), adduction and abduction range of motion (ROM) of the affected hip joint, Crowe classification, standing pelvic inclination in the coronal plane, Cobb angle and Japanese Orthopaedic Association Hip Disease Evaluation Questionnaire (JHEQ). RESULTS The absolute difference between pLLD and sLLD was modestly positively correlated with age (R=0.206; p<0.05) indicating older patients were less prone to perceive LLD. A strong positive correlation was found between pLLD (4.8±7.3mm; range: -37 to 28mm) and sLLD (6.4±7.0mm; range: -29.9 to 23.7mm) (R=0.714, p<0.05). The greater the pLLD, the smaller the hip abduction ROM (24.8±11.6°; range: 0 to 45°) tended to be, while the greater the sLLD, the smaller the hip abduction and adduction ROM (10.3±5.7°; range: 0 to 25°) tended to be (R= -0.259 and R= -0.297, respectively; p<0.05) The clinical significance of this finding is that pLLD may be improved if hip ROM training is performed before surgery. pLLD was significantly smaller in the group without pelvic inclination (8.0±14.1mm; range: -37 to 22mm) than in the group with pelvic inclination to the affected side (6.9±7.5mm; range: -12 to 28mm) and in the group with no inclination to the affected side (7.3±7.6mm; range: -8 to 25mm) (p<0.05) The clinical significance of this finding is that improving pelvic inclination with hip ROM training or muscle stretching may also reduce pLLD. No significant differences were noted between pLLD and JHEQ total scores or subgroups. DISCUSSION Older patients had less pLLD. Preoperative pLLD was strongly correlated with sLLD but not with patient satisfaction. These results may be useful for conservative treatment of OA, preoperative planning and intraoperative leg length correction. LEVEL OF EVIDENCE IV; case control study.
Collapse
|
39
|
Influence of kinematics of the lumbopelvic complex in hip arthroplasty dislocation: from assessment to recommendations. Arch Orthop Trauma Surg 2023:10.1007/s00402-022-04722-9. [PMID: 36717435 DOI: 10.1007/s00402-022-04722-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Accepted: 11/29/2022] [Indexed: 02/01/2023]
Abstract
INTRODUCTION In total hip arthroplasty (THA), misplacement of the implant can provide instability. Adequate orientation of the acetabular cup is a challenge due to variations in inter-individual anatomy and kinematics of the pelvis in everyday life. The aim of this study was to characterize the kinematic factors influencing the risk of dislocation in order to give recommendations for optimal placement of the cup. We hypothesized that the lack of pelvic adaptation would influence the risk of prosthetic instability and motivate adapted. MATERIALS AND METHODS Eighty patients with primary unilateral THA were included in a matched case-control study. Seventy-four patients were divided into two groups: group 1 (G1) consisting of patients with postoperative THA dislocation (37 patients) and group 2 (G2), without episodes of dislocation within two years postoperatively (37 patients). In both groups, spino-pelvic parameters and cup orientation were measured in standing and sitting positions with EOS® X-ray imaging and compared to each other between 12 and 24 months post-operatively. RESULTS No significant difference between the two groups was found for static parameters. In a sitting position, a lack of pelvic retroversion with a significant lower variation in sacral slope was observed in group 1 (8.0° ± 9.3 for G1 versus 14.7° ± 6.2 for G2, p < 0.01). Twenty-two (59%) patients with THA instability had sacral slope variations of less than 10° versus eight (21% of patients) with stable THA (p < 0.01). Cup orientation in the Lewinnek safe zone was not significantly different (59% vs 67%, p = 0.62), and the spino-pelvic parameters and cup orientation measured did not change between the standing and sitting positions. However, only 14 (37%) cups in G1 were in the functional safe zone versus 24 (67%) in G2 (p = 0.03). CONCLUSION Static parameters of the sagittal spinopelvic balance have a low predictive value for prosthetic instability. Dynamic analysis is essential. Kinematic parameters must be taken into account in determining the ideal position of the cup or stem. Stiffness with locked standing or sitting pelvis must be integrated in order to determine a personalized safe zone. LEVEL OF EVIDENCE Level III (matched case-control study).
Collapse
|
40
|
Hepinstall MS, Coden G, Salem HS, Naylor B, Matzko C, Mont MA. Consideration of pelvic tilt at the time of preoperative planning improves standing acetabular position after robotic-arm assisted total hip arthroplasty. Hip Int 2023; 33:47-52. [PMID: 34510940 DOI: 10.1177/11207000211038670] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
INTRODUCTION Approximately half of dislocating total hip arthroplasties (THAs) demonstrate acetabular component position within traditional safe zones. It is unclear if postoperative functional acetabular position can be reliably improved by considering preoperative pelvic tilt. We investigated whether standing cup position targets could be more accurately achieved by considering preoperative standing pelvic tilt in addition to bone landmarks when planning for robot-assisted THA. METHODS We reviewed 146 THAs performed by a single surgeon using computed tomography-based 3-dimensional planning and robotic technology to guide acetabular reaming and component insertion. Planning for 73 consecutive cases started at 40° of inclination and 22° of anteversion relative to the supine functional plane and was adjusted to better match native hip anatomy. Planning for the next 73 cases was modified to consider standing pelvic position based on standing preoperative radiographs. We compared groups to determine the rate when cups were placed outside our standing targets of 15-30° anteversion and 35-50° inclination. RESULTS Cup position proved to be reliable in both groups, with 83% of cups in the anatomic planning cohort and 90% of cups in the functional planning cohort achieving standing targets for both anteversion and inclination (p = 0.227). Variances were lower in the functional planning group: 9.4° versus 15.8° of inclination (p = 0.079) and 18.3° versus 26.1° of anteversion (p = 0.352). The range of functional positions was narrower in the functional planning group: 35.7-47.5° versus 31.8-54.9° of inclination and 16.7-35.0° versus 10.1-35.9° of anteversion. DISCUSSION Our results suggest enhanced planning that considers pelvic tilt, when coupled to a precision tool to achieve the plan, can reliably achieve target standing component positions. Considering preoperative functional pelvic position may improve postoperative functional acetabular component placement in THA, but the clinical benefit of this has yet to be confirmed.
Collapse
Affiliation(s)
- Matthew S Hepinstall
- Department of Orthopaedic Surgery, NYU Langone Health, New York, NY, USA.,Department of Orthopaedic Surgery, Lenox Hill Hospital, Northwell Health, New York, NY, USA
| | - Gloria Coden
- Department of Orthopaedic Surgery, Lenox Hill Hospital, Northwell Health, New York, NY, USA
| | - Hytham S Salem
- Department of Orthopaedic Surgery, Lenox Hill Hospital, Northwell Health, New York, NY, USA
| | - Brandon Naylor
- Department of Orthopaedic Surgery, Lenox Hill Hospital, Northwell Health, New York, NY, USA
| | - Chelsea Matzko
- Department of Orthopaedic Surgery, Lenox Hill Hospital, Northwell Health, New York, NY, USA
| | - Michael A Mont
- Department of Orthopaedic Surgery, Lenox Hill Hospital, Northwell Health, New York, NY, USA
| |
Collapse
|
41
|
The Impact of Hip Mobility on Lumbar and Pelvic Mobility before and after Total Hip Arthroplasty. J Clin Med 2022; 12:jcm12010331. [PMID: 36615131 PMCID: PMC9821212 DOI: 10.3390/jcm12010331] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 12/18/2022] [Accepted: 12/29/2022] [Indexed: 01/03/2023] Open
Abstract
Hip arthrosis and total hip arthroplasty (THA) can alter a patient's balance and spinopelvic mobility. In this study, we hypothesized that lumbar, pelvic, and hip mobility and their inter-relations are affected by THA and that their study could give an insight in our understanding of postoperative balance and mobility. A total of 165 patients with hip arthrosis and with an indication for THA were included in this single-center prospective cohort. Sagittal radiographs were acquired in four positions: free-standing, standing extension, relaxed-seating and flexed-seating preoperatively and at 6 and 12 months. Spinopelvic parameters were measured (pelvic tilt and incidence, sacral slope, lumbar lordosis, pelvic-femoral angle). Standing spinopelvic parameters did not significantly change postoperatively. However, the postural changes occurring between positions were significantly altered after THA. In particular, pelvic and lumbar mobility was significantly reduced postoperatively, while hip mobility was increased. Correlations were observed between the changes in lumbar, pelvic and hip mobility before and after THA. This study confirmed that there is a relationship between lumbar, pelvic and hip mobility in osteoarthritis, and that this relationship is modified by the postoperative compensation mechanisms deployed by the patient in dynamic postures. Hence, surgeons should consider these relationships when planning surgery, in order to obtain a physiological pelvic tilt postoperatively and to account for the potential increased risk of impingement and dislocation with hip hypermobility.
Collapse
|
42
|
Chen K, Wu J, Huang G, Liu C, Shen C, Zhu J, Li Y, Li T, Xiao F, Peng J, Han X, Zhang X, Xia J, Chen X. Variations in lower limb alignments indicate pelvic tilt after total hip arthroplasty. BMC Musculoskelet Disord 2022; 23:1116. [PMID: 36544147 PMCID: PMC9773480 DOI: 10.1186/s12891-022-06032-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Accepted: 11/25/2022] [Indexed: 12/24/2022] Open
Abstract
OBJECTIVE We sought to correlate various spinopelvic and lower limb alignments, and to examine the current spinopelvic theories on a Chinese cohort. METHODS We retrospectively reviewed 166 patients undergoing THA. Among them, 138 patients with unilateral THA met the inclusion criteria. Sagittal alignments and cup orientations were measured on standing and sitting lateral EOS images. Patients were categorized into two groups with a scoring system for lumbar spine degeneration. Patients' demographics including age, sex, lumbar spine degeneration and radiographic measurements were studied. RESULTS PT, SS, LL and TK differed significantly between standing and sitting within each group except for TK in degenerative group (32.8 ± 13.9 vs. 32.9 ± 14.2, p = 0.905). Compared with degenerative spine group, non-degenerative spine patients have great pelvic mobility (ΔPT, -24.4 ± 12.5° vs. -17.6 ± 10.7, p = 0.0008), greater lumbar mobility (ΔLL, -34.8 ± 15.2 vs. -21.7 ± 12.2, p = < 0.0001) and compensatory cup orientation changes (ΔRA, -15.5 ± 11.1 vs. -12.0 ± 8.4, p = 0.00920; ΔRI, -10.8 ± 11.5 vs. -5.6 ± 7.5, p = 0.0055). Standing PT and ankle dorsiflexion angle correlated positively (R2 = 0.236, p = 0.005). CONCLUSION THA patients in this cohort showed a spinopelvic motion paradigm similar to that from previous studies on Caucasians. Ankle dorsiflexion indicate greater posterior pelvic tilt on standing. Surgeons should beware of risks of instability in patients with lower limb compensations. ADVANCES IN KNOWLEDGE This study provides new insights into the clinical relevance of lower limb alignments to spinopelvic motion after THA in a relatively young Chinese population.
Collapse
Affiliation(s)
- Kangming Chen
- grid.8547.e0000 0001 0125 2443Department of Orthopaedics, Huashan Hospital, Fudan University, No.12 Middle Wulumuqi Road, Jing’an District, 200040 Shanghai, People’s Republic of China
| | - Jinyan Wu
- grid.412987.10000 0004 0630 1330Department of Orthopaedics, Xinhua Hospital affiliated to Shanghai Jiao Tong University School of medicine, No.1665 Kongjiang Road, Yangpu District, 200092 Shanghai, People’s Republic of China
| | - Gangyong Huang
- grid.8547.e0000 0001 0125 2443Department of Orthopaedics, Huashan Hospital, Fudan University, No.12 Middle Wulumuqi Road, Jing’an District, 200040 Shanghai, People’s Republic of China
| | - Changquan Liu
- grid.8547.e0000 0001 0125 2443Department of Orthopaedics, Huashan Hospital, Fudan University, No.12 Middle Wulumuqi Road, Jing’an District, 200040 Shanghai, People’s Republic of China ,grid.506261.60000 0001 0706 7839Present address: Graduate School of Peking Union Medical College and Chinese Academy of Medical Sciences, No. 9 Dongdan Santiao, Dongcheng District, 100730 Beijing, China ,grid.415954.80000 0004 1771 3349Present address: Department of Orthopaedic Surgery, China-Japan Friendship Hospital, No. 2 Yinghuayuan East Street, Chaoyang District, 100029 Beijing, China
| | - Chao Shen
- grid.412987.10000 0004 0630 1330Department of Orthopaedics, Xinhua Hospital affiliated to Shanghai Jiao Tong University School of medicine, No.1665 Kongjiang Road, Yangpu District, 200092 Shanghai, People’s Republic of China
| | - Junfeng Zhu
- grid.412987.10000 0004 0630 1330Department of Orthopaedics, Xinhua Hospital affiliated to Shanghai Jiao Tong University School of medicine, No.1665 Kongjiang Road, Yangpu District, 200092 Shanghai, People’s Republic of China
| | - Yang Li
- grid.412987.10000 0004 0630 1330Department of Orthopaedics, Xinhua Hospital affiliated to Shanghai Jiao Tong University School of medicine, No.1665 Kongjiang Road, Yangpu District, 200092 Shanghai, People’s Republic of China
| | - Tao Li
- grid.412987.10000 0004 0630 1330Department of Orthopaedics, Xinhua Hospital affiliated to Shanghai Jiao Tong University School of medicine, No.1665 Kongjiang Road, Yangpu District, 200092 Shanghai, People’s Republic of China
| | - Fei Xiao
- grid.412987.10000 0004 0630 1330Department of Orthopaedics, Xinhua Hospital affiliated to Shanghai Jiao Tong University School of medicine, No.1665 Kongjiang Road, Yangpu District, 200092 Shanghai, People’s Republic of China
| | - Jianping Peng
- grid.412987.10000 0004 0630 1330Department of Orthopaedics, Xinhua Hospital affiliated to Shanghai Jiao Tong University School of medicine, No.1665 Kongjiang Road, Yangpu District, 200092 Shanghai, People’s Republic of China
| | - Xiuguo Han
- grid.412987.10000 0004 0630 1330Department of Orthopaedics, Xinhua Hospital affiliated to Shanghai Jiao Tong University School of medicine, No.1665 Kongjiang Road, Yangpu District, 200092 Shanghai, People’s Republic of China
| | - Xinhai Zhang
- grid.412987.10000 0004 0630 1330Department of Orthopaedics, Xinhua Hospital affiliated to Shanghai Jiao Tong University School of medicine, No.1665 Kongjiang Road, Yangpu District, 200092 Shanghai, People’s Republic of China
| | - Jun Xia
- grid.8547.e0000 0001 0125 2443Department of Orthopaedics, Huashan Hospital, Fudan University, No.12 Middle Wulumuqi Road, Jing’an District, 200040 Shanghai, People’s Republic of China
| | - Xiaodong Chen
- grid.412987.10000 0004 0630 1330Department of Orthopaedics, Xinhua Hospital affiliated to Shanghai Jiao Tong University School of medicine, No.1665 Kongjiang Road, Yangpu District, 200092 Shanghai, People’s Republic of China
| |
Collapse
|
43
|
Montbarbon B, Letissier H, Di Francia R, Stindel E, Dubrana F, Williams T. Is a Total Hip Arthroplasty Stem in Varus a Risk Factor of Long-Term Mechanical Complication? J Arthroplasty 2022; 38:1104-1109. [PMID: 36535449 DOI: 10.1016/j.arth.2022.12.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Revised: 12/07/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND The impact of implanting cementless femoral stems in varus alignment on long-term mechanical complications remains poorly defined in the literature. The aim of our study was to compare survivorship and functional and radiographic outcomes of stems in varus alignment to those in neutral alignment with and average follow-up of 10 years. METHODS This single-center, multisurgeon, retrospective case-control study compared a group of 105 total hip arthroplasty (THA) patients who had varus stem alignment (Varus Stem) to a matching group of 105 THA patients who had neutral stem alignment, operated on between January 2007 and December 2012. The primary outcome measure was implant survival. Secondary outcomes included functional (Harris Hip Score, Postel Merle d'Aubigné Score, thigh pain, dislocation and hip range of motion) and radiographic outcomes (radiolucency, osseointegration, heterotopic ossification, subsidence, and stress shielding). RESULTS There was no significant difference in implant survival between the 2 groups with 95.7% (±2.46) in the Varus Stem group versus 97.7% (±1.64) in the Neutral Stem group (P = .41) after an average follow-up of 10 years. There was no significant difference in clinical and radiographic outcomes between groups. CONCLUSION Cementless femoral stems in varus alignment were not the cause of mechanical complications with an average follow-up of 10 years. The comparison between groups in terms of implant survival, functional, and radiographic outcomes does not show any significant differences. Positioning a femoral stem in varus alignment may be an alternative for surgeons wishing to restore preoperative offset and to ensure satisfactory hip stability.
Collapse
Affiliation(s)
- Baptiste Montbarbon
- Centre hospitalier d'Aubagne, Edmond Garcin, Hôpital d'Aubagne, Aubagne, France
| | - Hoel Letissier
- Service de Chirurgie Orthopédique et Traumatologique, CHRU de Brest, Brest, France; Laboratoire de Traitement de l'Information Médicale, LaTIM UMR 1101 INSERM UBO, Brest, France; Université de Bretagne Occidentale, Faculté de Médecine, Brest, France
| | - Rémi Di Francia
- Service de Chirurgie Orthopédique et Traumatologique, CHRU de Brest, Brest, France
| | - Eric Stindel
- Service de Chirurgie Orthopédique et Traumatologique, CHRU de Brest, Brest, France; Laboratoire de Traitement de l'Information Médicale, LaTIM UMR 1101 INSERM UBO, Brest, France; Université de Bretagne Occidentale, Faculté de Médecine, Brest, France
| | - Frédéric Dubrana
- Service de Chirurgie Orthopédique et Traumatologique, CHRU de Brest, Brest, France; Université de Bretagne Occidentale, Faculté de Médecine, Brest, France
| | - Thomas Williams
- Service de Chirurgie Orthopédique et Traumatologique, CHRU de Brest, Brest, France
| |
Collapse
|
44
|
Peng L, Zeng Y, Wu Y, Si H, Pei F, Shen B. Radiologic restoration inaccuracy increases postoperative dislocation in primary total hip arthroplasty: a retrospective study with propensity score matching. Arch Orthop Trauma Surg 2022; 142:3995-4005. [PMID: 34821944 DOI: 10.1007/s00402-021-04263-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 11/12/2021] [Indexed: 02/05/2023]
Abstract
BACKGROUND Dislocation is a complicated process and associated with multivariate etiology and risk factors. The purpose of this study was to verify if radiologic restoration inaccuracy increases postoperative dislocation in primary total hip arthroplasty (THA) individually or synergistically. METHODS From 2017 to 2020, we identified 76 (1.9%) patients who suffered postoperative dislocations from 3926 THAs in our institution. After excluded patients with previously proven patient-related and implant-related risk factors, the remaining patients were used to match a 1:1 control patients who were without dislocation. The cup position (inclination and anteversion angles), hip offset (HO), leg length discrepancy (LLD), and abductor lever arm (ALA) were analyzed by univariate analyses and multivariate logistic regressions. RESULTS Measurements on radiographs showed excellent interobserver agreement (intraclass correlation coefficient (ICC) 0.922-0.952) and intraobserver agreements (ICC 0.933-0.967). HO restoration inaccuracy (without ± 5 mm) was associated with higher dislocation risk (OR 4.241 95% CI 1.440-12.492, P = 0.009). The restoration inaccuracy of the cup position, LLD, or ALA could not increase the dislocation risk individually. When combining the radiologic restoration inaccuracy factors, the HO + LLD restoration inaccuracy and HO + ALA restoration inaccuracy increased the odds of postoperative dislocation (OR 12.056, 95% CI 1.409-103.127, P = 0.023; OR 4.770, 95% CI 1.336-17.028, P = 0.016, respectively). Combining the four risk factors of cup safe zone, HO, LLD, and ALA, patients with 3 or 4 radiologic restoration inaccuracy factors showed a higher risk of dislocation (OR 13.500, 95% CI 1.340-135.983, P = 0.027). CONCLUSION Hip offset (HO) restoration inaccuracy increased the risk of dislocation following primary THA. Multivariate radiologic restoration accuracy is critical for the prevention of dislocation and needs to be valued by surgeons.
Collapse
Affiliation(s)
- Linbo Peng
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan Province, 610041, People's Republic of China
| | - Yi Zeng
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan Province, 610041, People's Republic of China
| | - Yuangang Wu
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan Province, 610041, People's Republic of China
| | - Haibo Si
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan Province, 610041, People's Republic of China
| | - Fuxing Pei
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan Province, 610041, People's Republic of China
| | - Bin Shen
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan Province, 610041, People's Republic of China.
| |
Collapse
|
45
|
Khosravi B, Rouzrokh P, Maradit Kremers H, Larson DR, Johnson QJ, Faghani S, Kremers WK, Erickson BJ, Sierra RJ, Taunton MJ, Wyles CC. Patient-specific Hip Arthroplasty Dislocation Risk Calculator: An Explainable Multimodal Machine Learning-based Approach. Radiol Artif Intell 2022; 4:e220067. [PMID: 36523643 PMCID: PMC9745445 DOI: 10.1148/ryai.220067] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 07/30/2022] [Accepted: 09/12/2022] [Indexed: 06/17/2023]
Abstract
PURPOSE To develop a multimodal machine learning-based pipeline to predict patient-specific risk of dislocation following primary total hip arthroplasty (THA). MATERIALS AND METHODS This study retrospectively evaluated 17 073 patients who underwent primary THA between 1998 and 2018. A test set of 1718 patients was held out. A hybrid network of EfficientNet-B4 and Swin-B transformer was developed to classify patients according to 5-year dislocation outcomes from preoperative anteroposterior pelvic radiographs and clinical characteristics (demographics, comorbidities, and surgical characteristics). The most informative imaging features, extracted by the mentioned model, were selected and concatenated with clinical features. A collection of these features was then used to train a multimodal survival XGBoost model to predict the individualized hazard of dislocation within 5 years. C index was used to evaluate the multimodal survival model on the test set and compare it with another clinical-only model trained only on clinical data. Shapley additive explanation values were used for model explanation. RESULTS The study sample had a median age of 65 years (IQR: 18 years; 52.1% [8889] women) with a 5-year dislocation incidence of 2%. On the holdout test set, the clinical-only model achieved a C index of 0.64 (95% CI: 0.60, 0.68). The addition of imaging features boosted multimodal model performance to a C index of 0.74 (95% CI: 0.69, 0.78; P = .02). CONCLUSION Due to its discrimination ability and explainability, this risk calculator can be a potential powerful dislocation risk stratification and THA planning tool.Keywords: Conventional Radiography, Surgery, Skeletal-Appendicular, Hip, Outcomes Analysis, Supervised Learning, Convolutional Neural Network (CNN), Gradient Boosting Machines (GBM) Supplemental material is available for this article. © RSNA, 2022.
Collapse
|
46
|
Hardwick-Morris M, Twiggs J, Kacker K, Miles B, Balakumar J. Functional Femoral Anteversion: Axial Rotation of the Femur and its Implications for Stem Version Targets in Total Hip Arthroplasty. Arthroplast Today 2022; 18:16-23. [PMID: 36267395 PMCID: PMC9576488 DOI: 10.1016/j.artd.2022.09.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 08/13/2022] [Accepted: 09/06/2022] [Indexed: 11/25/2022] Open
Abstract
Background Acetabular and femoral component positioning are important considerations in reducing adverse outcomes after total hip arthroplasty (THA). Previous assessments of femoral anteversion examined anatomic femoral anteversion (AFA) referenced to anatomic landmarks. However, this does not provide a functional understanding of the femur's relationship to the hip. We investigate a new measurement, functional femoral anteversion (FFA), and sought to measure its variability across a large sample of patients undergoing THA. Methods A total of 1008 consecutive patients underwent THA surgery between September 2019 and July 2021. All patients were measured for supine and standing functional femoral rotation (FFR), AFA, and FFA. Results The mean standing FFA was 13.2° ± 12.2° (-27.8° to 52.3°). The mean change in FFR from supine to standing was -2.2° ± 11.8° (-43.0° to 41.9°). Of all, 161 (16%) patients had standing FFA version greater than 25°. Four hundred sixty (46%) patients had standing FFR (internal or external) greater than 10°. One hundred twenty-three (12%) patients exhibited an increase in external rotation from supine to standing of greater than 10°. A moderate, negative linear relationship was observed between AFA and standing external femoral rotation (P <<.001, R = -0.46), indicating people may externally rotate their femur as AFA decreases with age. Conclusions Functional alignment of the femur in patients requiring THA is understudied. It is now understood that the femur, like the pelvis, can rotate substantially between functional positions. Enhancing our understanding of FFA and FFR may improve both acetabular and femoral component positioning.
Collapse
Affiliation(s)
- Max Hardwick-Morris
- Flinders University, Adelaide, South Australia, Australia,360 Med Care, Sydney, New South Wales, Australia,Corresponding author. 360 Med Care, Suite 3, Building 1/20 Bridge Street, Pymble, New South Wales, Australia. Tel.: +61 406 937 050.
| | | | | | - Brad Miles
- 360 Med Care, Sydney, New South Wales, Australia
| | | |
Collapse
|
47
|
Jungwirth-Weinberger A, Schmidt-Braekling T, Rueckl K, Springer B, Boettner F. Anterior hip replacement: lower dislocation rates despite less restrictions? Arch Orthop Trauma Surg 2022; 142:2413-2417. [PMID: 33687529 DOI: 10.1007/s00402-021-03849-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Accepted: 02/27/2021] [Indexed: 11/27/2022]
Abstract
INTRODUCTION Dislocation in Total hip arthroplasty (THA) is a common postoperative complication and reason for revision surgery. The direct anterior approach has become more popular over the last decade. The purpose of this study was to compare postoperative dislocation rates of the direct anterior and the posterior approach at a one-year follow-up. MATERIAL AND METHODS 797 consecutive hips operated through a posterior approach [698 patients (307 male, 391 female)] between 2009 and 2012, were compared to 690 selected THA [610 patients (423 female, 187 male)] operated since 2012. Anterior hip replacement surgery was primarily indicated for patients demanding increased flexibility after surgery (Yoga) or were considered a higher risk for dislocation. RESULTS During a one-year follow-up there were eight dislocations out of 797 THA (1%) in the posterior group and none in the 690 THA (0%) in the anterior group (p-value of 0.008). Average time to dislocation was 7.5 weeks in the posterior group. Five of eight patients with dislocations needed revision surgery due to persistent instability. CONCLUSION Even in a higher-risk patient population, the direct anterior approach showed a lower dislocation rate compared to the posterior approach in the first year after surgery.
Collapse
Affiliation(s)
- Anna Jungwirth-Weinberger
- Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA
- Kantonsspital Baden, Im Ergel 1, 5404, Baden, Switzerland
| | | | - Kilian Rueckl
- Julius-Maximilians-Universität Würzburg, Brettreichstr. 11, 97074, Würzburg, Germany
| | | | - Friedrich Boettner
- Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
| |
Collapse
|
48
|
Becker L, Taheri N, Haffer H, Muellner M, Hipfl C, Ziegeler K, Diekhoff T, Pumberger M. Lumbosacral Transitional Vertebrae Influence on Acetabular Orientation and Pelvic Tilt. J Clin Med 2022; 11:jcm11175153. [PMID: 36079079 PMCID: PMC9457479 DOI: 10.3390/jcm11175153] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2022] [Revised: 08/26/2022] [Accepted: 08/26/2022] [Indexed: 11/16/2022] Open
Abstract
Lumbosacral transitional vertebrae (LSTV) are common congenital variances with a prevalence found in the population up to 35.6%. The literature demonstrates an influence of LSTV on bony pelvic anatomy. The influence on the anatomical acetabular orientation, which is important for cup positioning in total hip arthroplasty, has not yet been described for patients with LSTV. A total of 53 patients with LSTV were identified from a CT Database including 819 subjects. Fifty patients with LSTV could be included and were matched for age and sex against a control group. We examined the influence of LSTV, classified according to Castellvi, on acetabular orientation and pelvic tilt in the supine position. Functional acetabular anteversion and inclination, assessed against the table plane, were compared against anatomical acetabular anteversion and inclination, assessed against the anterior pelvic plane. The anatomical acetabular inclination correlated with the pelvic tilt (r = 0.363, p < 0.001). The anatomical acetabular inclination was significantly larger than the functional acetabular inclination in the supine position (p < 0.001). Castellvi grading of LSTV correlated negatively with pelvic tilt (ρ = −0.387, p = 0.006). Castellvi grading correlated significantly with functional acetabular anteversion (ρ = 0.324, p = 0.022) and anatomical acetabular anteversion (ρ = 0.306, p = 0.022). A higher Castellvi grading was accompanied by a reduced pelvic tilt in the supine position. The functional acetabular anteversion and anatomical acetabular anteversion increased in parallel to the higher Castellvi grading. Therefore, LSTV and Castellvi grading might be assessed on pre-operative X-rays prior to hip arthroplasty and surgeons might consider adjusting cup positioning accordingly.
Collapse
Affiliation(s)
- Luis Becker
- Center for Musculoskeletal Surgery, Charité—University Medicine, Charitéplatz 1, 10117 Berlin, Germany
- Berlin Institute of Health, Julius Wolff Institute for Biomechanics and Musculoskeletal Regeneration, Charité—University Medicine, Augustenburger Pl. 1, 13353 Berlin, Germany
- Correspondence:
| | - Nima Taheri
- Center for Musculoskeletal Surgery, Charité—University Medicine, Charitéplatz 1, 10117 Berlin, Germany
| | - Henryk Haffer
- Center for Musculoskeletal Surgery, Charité—University Medicine, Charitéplatz 1, 10117 Berlin, Germany
| | - Maximilian Muellner
- Center for Musculoskeletal Surgery, Charité—University Medicine, Charitéplatz 1, 10117 Berlin, Germany
| | - Christian Hipfl
- Center for Musculoskeletal Surgery, Charité—University Medicine, Charitéplatz 1, 10117 Berlin, Germany
| | - Katharina Ziegeler
- Department for Radiology, Charité—University Medicine, Charitéplatz 1, 10117 Berlin, Germany
| | - Torsten Diekhoff
- Department for Radiology, Charité—University Medicine, Charitéplatz 1, 10117 Berlin, Germany
| | - Matthias Pumberger
- Center for Musculoskeletal Surgery, Charité—University Medicine, Charitéplatz 1, 10117 Berlin, Germany
| |
Collapse
|
49
|
Reichert JC, Wassilew GI, von Rottkay E, Noeth U. Compared learning curves of the direct anterior and anterolateral approach for minimally invasive hip replacement. Orthop Rev (Pavia) 2022; 14:37500. [PMID: 36034727 PMCID: PMC9404252 DOI: 10.52965/001c.37500] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/28/2023] Open
Abstract
Minimally invasive hip arthroplasty becomes increasingly popular. It is technically challenging and the approaches used are associated with a considerable learning curve. This nurtures concerns regarding patient safety, surgical training, and cost effectiveness. Consequently, we initiated a study comparing the learning curves of a supervised trainee surgeon utilizing both the anterolateral and direct anterior approach (DAA) when introduced to minimally invasive hip replacement surgery. Outcome measurements included the Harris hip score (HHS), cup inclination and anteversion, offset and leg length, stem placement, surgical time and complications. Time from incision to suture decreased significantly over time but did not differ between both groups. The functional outcomes (HHS) after six weeks and three months were comparable (p=0.069 and 0.557) and within the expected range equalling 90.3 (anterior) and 89.2 (anterolateral) points. With both approaches safe component placement was readily achieved. Both offset and leg length, however, were reconstructed more reliably with the DAA (p=0.02 and 0.001). A higher rate of dislocations was seen with the anterior, more perioperative infections with the anterolateral approach. We suggest that supervision by an experienced surgeon favourably influences the learning curves for both the minimally invasive DAA and anterolateral approach and conclude that the greatest improvement is seen within the first 60 cases.
Collapse
Affiliation(s)
- Johannes C Reichert
- Department of Orthopedics and Orthopaedic Surgery, University Medicine Greifswald; Department of Orthopaedic and Trauma Surgery, Evangelisches Waldkrankenhaus Spandau
| | - Georgi I Wassilew
- Department of Orthopedics and Orthopaedic Surgery, University Medicine Greifswald
| | - Eberhard von Rottkay
- Department of Orthopaedic and Trauma Surgery, Evangelisches Waldkrankenhaus Spandau
| | - Ulrich Noeth
- Department of Orthopaedic and Trauma Surgery, Evangelisches Waldkrankenhaus Spandau
| |
Collapse
|
50
|
The application of custom-made 3D-printed titanium augments designed through surgical simulation for severe bone defects in complex revision total hip arthroplasty. J Orthop Traumatol 2022; 23:37. [PMID: 35932367 PMCID: PMC9357241 DOI: 10.1186/s10195-022-00656-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Accepted: 07/12/2022] [Indexed: 11/23/2022] Open
Abstract
Background With the development of radiology and three-dimensional (3D) printing technology, custom-made 3D-printed titanium augments have been more widely used. However, the radiological and clinical outcomes of custom-made augments lack reports. To better understand the clinical effect of using 3D-printed titanium augments and the significance of accurate placement, the aim of this study was to assess the outcomes when using custom-made 3D-printed titanium augments and to validate the idea that surgical simulation should be done before designing custom-made augments. Methods A retrospective review was conducted on 31 surgical simulations and revision total hip arthroplasties using custom-made 3D-printed titanium augments. The safe zone, cup position, and hip rotation center were measured on anteroposterior radiographs. Clinical outcomes were assessed with a mean 21.1 months of follow-up. Results All patients were positioned within the safe zone, and none of the acetabular cups nor the custom-made augments had any evidence of migration at the latest follow-up. A strong correlation was found between the planned cup position and the postoperative position. The average vertical position of the center of rotation was significantly increased from 3.55 cm to 2.35 cm. The mean Harris Hip Score was increased from 40.81 preoperatively to 65.46 postoperatively. Complications included gait abnormality, groin pain, fracture of the greater trochanter, and partial palsy of the sciatic nerve. However, patient satisfaction reached 92.3%. Conclusion Surgical simulations help to design custom-made augments accurately and improve surgical plans. Acetabular components supported with custom-made 3D-printed augments is a useful method to bridge severe bone deficiencies. In this study, both the radiologic results and clinical outcomes were favorable. Level of evidence Level 4. Supplementary Information The online version contains supplementary material available at 10.1186/s10195-022-00656-5.
Collapse
|