1
|
Alavi N, Malekpour A. Fe 3O 4@SiO 2/GO/HKUST-1 nanocomposite for quercetin extraction and preconcentration followed by its determination using HPLC. J Food Sci 2025; 90:e17603. [PMID: 39828413 DOI: 10.1111/1750-3841.17603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2024] [Revised: 11/07/2024] [Accepted: 11/25/2024] [Indexed: 01/22/2025]
Abstract
Quercetin, a key flavonoid found in many fruits and vegetables, offers notable health benefits, including antioxidant, antiviral, and antitumor properties. Yet, isolating it from complex plant materials is challenging. This research aimed to develop a selective and efficient sorbent to clean up real sample matrices and pre-concentrate quercetin, enhancing its detection using high-performance liquid chromatography (HPLC). Several metal organic frameworks (MOFs) were synthesized and initially, their abilities to sorption of quercetin from aqueous and alcohol media were examined. Among them, HKUST-1 showed the best performance. To improve the efficiency of this MOF, its composite with graphene oxide (GO) was prepared (Fe3O4@SiO2/GO/HKUST-1) and was employed for quercetin extraction through magnetic dispersive micro solid-phase extraction. The effect of different parameters was examined and the kinetic, thermodynamic, and isotherm of the sorption process was studied. The related results showed the system followed the pseudo-second-order kinetic model, with the Temkin and Langmuir isotherm models applicable in aqueous and methanol solutions, respectively. The method enabled rapid preconcentration and clean up within 20 min, with a 99.6% adsorption efficiency using just 5 mg of sorbent. The nanocomposite demonstrated an adsorption capacity of 29.3 mg/g and effectively extracted quercetin from red onion samples, achieving recovery rates between 75% and 98% for HPLC-diode array detector analysis. PRACTICAL APPLICATION: Quercetin is a common polyphenolic compound, which is widely found in plant materials such as onions. Owing to its medicinal effects including anti-inflammatory, anti-oxidant, anti-cancer, cardioprotective, anti-bacterial, anti-viral, and anti-allergic features, it has widespread usage in pharmacology and preparation of food preservers. In this study, Fe3O4@SiO2/GO/HKUST-1 nanocomposite was synthesized for extraction and preconcentration of quercetin from an onion sample. Very low amounts of this sorbent indicated high adsorption percentage and adsorption capacity for quercetin. This method was simple, fast, cost-effective, precise, and accurate, which exhibited a potential for extraction of quercetin in a large scale.
Collapse
Affiliation(s)
- Nikoo Alavi
- Department of Chemistry, University of Isfahan, Isfahan, Iran
| | - Akbar Malekpour
- Department of Chemistry, University of Isfahan, Isfahan, Iran
| |
Collapse
|
2
|
Bedair A, Abdelhameed RM, Hammad SF, Abdallah IA, Mansour FR. Applications of metal organic frameworks in dispersive micro solid phase extraction (D-μ-SPE). J Chromatogr A 2024; 1732:465192. [PMID: 39079363 DOI: 10.1016/j.chroma.2024.465192] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Revised: 07/05/2024] [Accepted: 07/18/2024] [Indexed: 08/23/2024]
Abstract
Metal-organic frameworks (MOFs) are a fascinating family of crystalline porous materials made up of metal clusters and organic linkers. In comparison with other porous materials, MOFs have unique characteristics including high surface area, homogeneous open cavities, and permanent high porosity with variable shapes and sizes. For these reasons, MOFs have recently been explored as sorbents in sample preparation by solid-phase extraction (SPE). However, SPE requires large amounts of sorbents and suffers from limited contact surfaces with analytes, which compromises extraction recovery and efficiency. Dispersive SPE (D-SPE) overcomes these limitations by dispersing the sorbents into the sample, which in turn increases contact with the analytes. Miniaturization of the microextraction procedure, particularly the amount of sorbent reduces the amount consumed of the organic solvent and shorten the time required to attain the equilibrium state. This may explain the reported high efficiency and applicability of MOFs in dispersive micro SPE (D-µ-SPE). This method retains all the advantages of solid phase extraction while also being simpler, faster, cheaper, and, in some cases, more effective in comparison with D-SPE. Besides, D-µ-SPE requires smaller amounts of the sorbents which reduces the overall cost, and the amount of waste generated from the analytical process. In this review, we discuss the applications of MOFs in D-µ-SPE of various analytes including pharmaceuticals, pesticides, organic dyes from miscellaneous matrices including water samples, biological samples and food samples.
Collapse
Affiliation(s)
- Alaa Bedair
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, 32897, Monufia, Egypt
| | - Reda M Abdelhameed
- Applied Organic Chemistry Department, Chemical Industries Research Institute, National Research Centre, Giza 12622, Egypt
| | - Sherin F Hammad
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, 31111 Egypt
| | - Inas A Abdallah
- Department of Analytical Chemistry, Faculty of Pharmacy, University of Sadat City, Sadat City, 32897, Monufia, Egypt
| | - Fotouh R Mansour
- Department of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Tanta University, Tanta, 31111 Egypt.
| |
Collapse
|
3
|
Karaket R, Detsri E, Khattiya A, Monvisade P, Mathaweesansurn A. Facile construction of magnetic solid-phase extraction of polyaniline blend poly(amidoamine) dendrimers modified graphene oxide quantum dots for efficient adsorption of polycyclic aromatic hydrocarbons in environmental water. J Chromatogr A 2024; 1717:464668. [PMID: 38278132 DOI: 10.1016/j.chroma.2024.464668] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Revised: 01/15/2024] [Accepted: 01/18/2024] [Indexed: 01/28/2024]
Abstract
An efficient magneto-adsorbent composed of polyaniline blend poly(amidoamine) dendrimers modified graphene oxide quantum dots and magnetic Fe3O4 particles (Fe3O4@PANI-PSS/PAMAM-QGO) for magnetic solid-phase extraction (MSPE) of polycyclic aromatic hydrocarbons (PAHs) in environmental water was synthesized. Fe3O4@PANI-PSS/PAMAM-QGO exhibited exceptional adsorption property for most PAHs analytes. The nanocomposite sorbent demonstrated a ferromagnetic behavior of 17.457 emu g-1, which is adequate for subsequent use in MSPE. Key parameters affecting the processes of adsorption and desorption, including the sorbent amount, vortex adsorption time, vortex extraction time, sample volume, a solvent for desorption and the solvent volume were all examined and optimized. The performance of MSPE using Fe3O4@PANI-PSS/PAMAM-QGO as adsorbent for four PAHs, including fluoranthene, acenaphthene, phenanthrene and pyrene were studied through high performance liquid chromatography equipped with spectrofluorometer. Under the optimal conditions, Fe3O4@PANI-PSS/PAMAM-QGO showed a wide linearity of 10-1,000 ng mL-1, low detection limit (LOD) ranging from 1.92 to 4.25 ng mL -1 and high accuracy (recoveries of 93.6-96.5 %). Enrichment factors up to 185 were achieved. Furthermore, Fe3O4@PANI-PSS/PAMAM-QGO exhibited good recyclability (10 times, RSDs ≤ 5.35%), while maintaining its high efficiency in the extraction of PAHs. The proposed method was successfully applied for environmental samples. Recoveries ranging from 81.2 to 106.2 % were obtained, indicating a low matrix effect and the robustness of the optimized MSPE method. Based on these features and under the optimal extraction conditions, Fe3O4@PANI-PSS/PAMAM-QGO was demonstrated to be a successful tool for the rapid and sensitive extraction of PAHs in the samples.
Collapse
Affiliation(s)
- Ratchanok Karaket
- Department of Chemistry, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand
| | - Ekarat Detsri
- Department of Chemistry, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand; Integrated Applied Chemistry Research Unit, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
| | - Akrarath Khattiya
- Department of Chemistry, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand
| | - Pathavuth Monvisade
- Department of Chemistry, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand; Polymer Synthesis and Functional Materials Research Unit, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand
| | - Arjnarong Mathaweesansurn
- Department of Chemistry, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand; Applied Analytical Chemistry Research Unit, School of Science, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
| |
Collapse
|
4
|
Peng X, Liu L, Hu X, Yan W, Zheng D, Xia Z, Yu Q, Zhou Y, Xia H, Peng L. Facile fabrication of naphthalene-functionalized magnetic nanoparticles for efficient extraction of polycyclic aromatic hydrocarbons from environmental water and fish samples. J Chromatogr A 2023; 1706:464229. [PMID: 37506458 DOI: 10.1016/j.chroma.2023.464229] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2023] [Revised: 07/16/2023] [Accepted: 07/19/2023] [Indexed: 07/30/2023]
Abstract
In this study, naphthalene-modified magnetic nanoparticles (Fe3O4@Nap) were simply prepared based on specific chelation interaction between phosphate groups and metal ions on Fe3O4 surface. The resultant Fe3O4@Nap were characterized by FTIR, BET, SEM, TEM, NAM, TGA, and VSM techniques. With Fe3O4@Nap as adsorbent, the polycyclic aromatic hydrocarbons (PAHs) were efficiently extracted by magnetic solid-phase extraction (MSPE) from environmental water and fish samples through the π-π interaction between modified naphthalene groups and PAHs, followed by their determination by GC-MS/MS. The key parameters influencing the extraction efficiency were investigated. Under the optimized conditions, the Fe3O4@Nap-based MSPE/GC-MS/MS method proposed in this paper was evaluated and applied for analyzing PAHs in environmental water and fish samples. And the proposed MSPE/GC-MS/MS method exhibited good linearities for water samples (in the range of 0.1-10 ng/mL, R2 >0.9945) and for fish samples (in the range of 1-100 ng/g, R2 > 0.9905). The limits of detection (LODs) for water and fish samples were 0.004-0.031 ng/mL and 0.07-0.28 ng/g, respectively. Additionally, this method exhibited desirable accuracy and precision. The PAH recovery values from water and fish samples ranged from 81.5% to 109.6% with inter- and intra-day relative standard deviations (RSDs) of less than 12.8%. The MSPE/GC-MS/MS method was successfully applied to the analysis of real environmental water and fish samples. Overall, the newly synthesized Fe3O4@Nap exhibited high sensitivity, specificity, reusability, repeatability, and it could efficiently extract PAHs from environmental water and fish samples by MSPE.
Collapse
Affiliation(s)
- Xitian Peng
- Hubei Academy of Agricultural Sciences/Hubei Key Laboratory of Nutritional Quality and Safety of Agro products, Institute of Agricultural Quality Standards and Testing Technology Research, Wuhan, Hubei 430064, PR China
| | - Li Liu
- Hubei Academy of Agricultural Sciences/Hubei Key Laboratory of Nutritional Quality and Safety of Agro products, Institute of Agricultural Quality Standards and Testing Technology Research, Wuhan, Hubei 430064, PR China
| | - Xizhou Hu
- Hubei Academy of Agricultural Sciences/Hubei Key Laboratory of Nutritional Quality and Safety of Agro products, Institute of Agricultural Quality Standards and Testing Technology Research, Wuhan, Hubei 430064, PR China
| | - Wei Yan
- Hubei Academy of Agricultural Sciences/Hubei Key Laboratory of Nutritional Quality and Safety of Agro products, Institute of Agricultural Quality Standards and Testing Technology Research, Wuhan, Hubei 430064, PR China
| | - Dan Zheng
- Hubei Academy of Agricultural Sciences/Hubei Key Laboratory of Nutritional Quality and Safety of Agro products, Institute of Agricultural Quality Standards and Testing Technology Research, Wuhan, Hubei 430064, PR China
| | - Zhenzhen Xia
- Hubei Academy of Agricultural Sciences/Hubei Key Laboratory of Nutritional Quality and Safety of Agro products, Institute of Agricultural Quality Standards and Testing Technology Research, Wuhan, Hubei 430064, PR China
| | - Qiongwei Yu
- Department of Chemistry, Wuhan University, Wuhan, Hubei 430072, PR China
| | - Youxiang Zhou
- Hubei Academy of Agricultural Sciences/Hubei Key Laboratory of Nutritional Quality and Safety of Agro products, Institute of Agricultural Quality Standards and Testing Technology Research, Wuhan, Hubei 430064, PR China.
| | - Hong Xia
- Hubei Academy of Agricultural Sciences/Hubei Key Laboratory of Nutritional Quality and Safety of Agro products, Institute of Agricultural Quality Standards and Testing Technology Research, Wuhan, Hubei 430064, PR China.
| | - Lijun Peng
- Hubei Academy of Agricultural Sciences/Hubei Key Laboratory of Nutritional Quality and Safety of Agro products, Institute of Agricultural Quality Standards and Testing Technology Research, Wuhan, Hubei 430064, PR China.
| |
Collapse
|
5
|
Zhu Z, Xu Y, Huang T, Yu Y, Bassey AP, Huang M. The contamination, formation, determination and control of polycyclic aromatic hydrocarbons in meat products. Food Control 2022. [DOI: 10.1016/j.foodcont.2022.109194] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
6
|
Abstract
Developing effective and green methods for food analysis and separation has become an urgent issue regarding the ever-increasing concern of food quality and safety. Ionic liquids (ILs) are a new chemical medium and soft functional material developed under the framework of green chemistry and possess many unique properties, such as low melting points, low-to-negligible vapor pressures, excellent solubility, structural designability and high thermal stability. Combining ILs with extraction techniques not only takes advantage of ILs but also overcomes the disadvantages of traditional extraction methods. This subject has attracted intensive research efforts recently. Here, we present a brief review of the current research status and latest developments regarding the application of IL-assisted microextraction, including dispersive liquid–liquid microextraction (DLLME) and solid-phase microextraction (SPME), in food analysis and separation. The practical applications of ILs in determining toxic and harmful substances in food specimens with quite different natures are summarized and discussed. The critical function of ILs and the advantages of IL-based microextraction techniques over conventional extraction techniques are discussed in detail. Additionally, the recovery of ILs using different approaches is also presented to comply with green analytical chemistry requirements.
Collapse
|
7
|
Hojjati-Najafabadi A, Mansoorianfar M, Liang T, Shahin K, Karimi-Maleh H. A review on magnetic sensors for monitoring of hazardous pollutants in water resources. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 824:153844. [PMID: 35176366 DOI: 10.1016/j.scitotenv.2022.153844] [Citation(s) in RCA: 113] [Impact Index Per Article: 37.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Revised: 02/01/2022] [Accepted: 02/09/2022] [Indexed: 06/14/2023]
Abstract
Water resources have long been of interest to humans and have become a serious issue in all aspects of human life. The disposal of hazardous pollutants in water resources is one of the biggest global concerns and poses many risks to human health and aquatic life. Therefore, the control of hazardous pollutants in water resources plays an important role, when it comes to evaluating water quality. Due to low toxicity, good electrical conductivity, facile functionalization, and easy preparation, magnetic materials have become a good alternative in recent years to control hazardous pollutants in water resources. In the present study, the idea of using magnetic sensors in controlling and monitoring of pharmaceuticals, pesticides, heavy metals, and organic pollutants have been reviewed. The water pollutants in drinking water, groundwater, surface water, and seawater have been discussed. The toxicology of water hazardous pollutants has also been reviewed. Then, the magnetic materials were discussed as sensors for controlling and monitoring pollutants. Finally, future remarks and perspectives on magnetic nanosensors for controlling hazardous pollutants in water resources and environmental applications were explained.
Collapse
Affiliation(s)
- Akbar Hojjati-Najafabadi
- College of Rare Earths, Jiangxi University of Science and Technology, No. 86, Hongqi Ave., Ganzhou, Jiangxi 341000, PR China; Faculty of Materials, Metallurgy and Chemistry, School of Materials Science and Engineering, Jiangxi University of Science and Technology, Ganzhou 341000, PR China.
| | - Mojtaba Mansoorianfar
- CAS Key Laboratory for Nano-Bio Interface, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences, Suzhou 215123, China
| | - Tongxiang Liang
- College of Rare Earths, Jiangxi University of Science and Technology, No. 86, Hongqi Ave., Ganzhou, Jiangxi 341000, PR China
| | - Khashayar Shahin
- Center for Microbes, Development, and Health (CMDH), Institute Pasteur of Shanghai, Chinese Academy of Sciences, Shanghai 200025, China
| | - Hassan Karimi-Maleh
- School of Resources and Environment, University of Electronic Science and Technology of China, Chengdu 611731, PR China; Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran; Department of Chemical Sciences, University of Johannesburg, Doornfontein Campus, 2028 Johannesburg, South Africa.
| |
Collapse
|
8
|
Sohrabi-Gilani N, Ghayournezhad A, Rostamzadeh Mansour S. Determination of Ultratrace Levels of Cobalt (II) and Chromium (III) by Magnetic Dispersive Solid-Phase Extraction (SPE) Using Urea-Formaldehyde Polymer/Magnetite Nanoparticles with Flame Atomic Absorption Spectrometry (FAAS). ANAL LETT 2022. [DOI: 10.1080/00032719.2022.2067863] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
|
9
|
Metal-organic framework-based magnetic dispersive micro-solid-phase extraction for the gas chromatography–mass spectrometry determination of polycyclic aromatic compounds in water samples. J Chromatogr A 2022; 1671:463010. [DOI: 10.1016/j.chroma.2022.463010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/15/2022] [Accepted: 03/29/2022] [Indexed: 12/21/2022]
|
10
|
Zhang H, Hu X, Xia H, Zhou Y, Peng L, Wu J, Peng X. Amine-functionalized MIL-101(Fe) for highly selective and efficient extraction of phenoxy carboxylic acid herbicides from environmental water and rice samples. CHEMICAL PAPERS 2022. [DOI: 10.1007/s11696-022-02103-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
11
|
Manousi N, Kabir A, Furton KG, Rosenberg E, Zachariadis GA. Fabric phase sorptive extraction combined with gas chromatography-mass spectrometry as an innovative analytical technique for the determination of selected polycyclic aromatic hydrocarbons in herbal infusions and tea samples. RSC Adv 2022; 12:7149-7156. [PMID: 35424701 PMCID: PMC8982215 DOI: 10.1039/d2ra00408a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Accepted: 02/18/2022] [Indexed: 11/21/2022] Open
Abstract
This study presents a fabric phase sorptive extraction (FPSE) protocol for the isolation and preconcentration of four selected polycyclic aromatic hydrocarbons from tea samples and herbal infusions, followed by their separation and quantification by gas chromatography-mass spectrometry (GC-MS). In FPSE, extraction of the target analytes is performed utilizing a flexible fabric substrate that is coated with a highly efficient sol–gel sorbent. In this work, eighteen different FPSE membranes were examined, with the highest extraction recoveries being observed with the sol–gel C18 coated FPSE membrane. The main parameters that influence the adsorption and desorption of the PAHs were optimized and the proposed method was validated. The detection limits and the quantification limits were 0.08–0.17 ng mL−1 and 0.25–0.50 ng mL−1, respectively, for the different target compounds with a 10 mL sample. The relative standard deviations for intra-day and inter-day repeatability were less than 7.9% and 8.5%, respectively. The sol–gel C18 coated FPSE membrane could be used for at least 5 subsequent sample preparation cycles. Finally, the proposed protocol was successfully employed for the determination of PAHs in a wide range of tea and herbal infusion samples. A fabric phase sorptive extraction (FPSE) protocol for the isolation and preconcentration of four selected polycyclic aromatic hydrocarbons from tea samples and herbal infusions is presented, followed by their quantitative analysis by GC-MS.![]()
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki Thessaloniki 54124 Greece.,Institute of Chemical Technologies and Analytics, Vienna University of Technology Getreidemarkt 9/164 1060 Vienna Austria
| | - Abuzar Kabir
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University Miami FL USA.,Department of Pharmacy, Faculty of Allied Health Sciences, Daffodil International University Dhaka-1207 Bangladesh
| | - Kenneth G Furton
- International Forensic Research Institute, Department of Chemistry and Biochemistry, Florida International University Miami FL USA
| | - Erwin Rosenberg
- Institute of Chemical Technologies and Analytics, Vienna University of Technology Getreidemarkt 9/164 1060 Vienna Austria
| | - George A Zachariadis
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki Thessaloniki 54124 Greece
| |
Collapse
|
12
|
Ali N, Hassan Riead MM, Bilal M, Yang Y, Khan A, Ali F, Karim S, Zhou C, Wenjie Y, Sher F, Iqbal HMN. Adsorptive remediation of environmental pollutants using magnetic hybrid materials as platform adsorbents. CHEMOSPHERE 2021; 284:131279. [PMID: 34175517 DOI: 10.1016/j.chemosphere.2021.131279] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 06/13/2021] [Accepted: 06/16/2021] [Indexed: 02/07/2023]
Abstract
Effective separation and remediation of environmentally hazardous pollutants are burning areas of research because of a constant increase in environmental pollution problems. An extensive number of emerging contaminants in the environmental matrices result in serious health consequences in animals, humans, and plants, even at trace levels. Therefore, it is of paramount significance to quantify these undesirable pollutants, even at a very low concentration, from the natural environment. Magnetic solid-phase extraction (MSPE) has recently achieved huge attention because of its strong magnetic domain and easy separation through an external magnetic field compared with simple solid-phase extraction. Therefore, MSPE appeared the most promising technique for removing and pre-concentration of emerging pollutants at trace level. Compared to the normal solid-phase extraction, MSPE as magnetic hybrid adsorbents offers the unique advantages of distinct nanomaterials and magnetic hybrid materials. It can exhibit efficient dispersion and rapid recycling when applying to a very complex matrix. This review highlights the possible environmental applications of magnetic hybrid nanoscale materials as effective MSPE sorbents to remediate a diverse range of environmentally toxic pollutants. We believe this study tends to evoke a variety of research thrust that may lead to novel remediation approaches in the forthcoming years.
Collapse
Affiliation(s)
- Nisar Ali
- Key Laboratory of Regional Resource Exploitation and Medicinal Research, Faculty of Chemical Engineering, Huaiyin Institute of Technology, Huaian, Jiangsu Province, PR China.
| | - Md Mahamudul Hassan Riead
- Key Laboratory of Regional Resource Exploitation and Medicinal Research, Faculty of Chemical Engineering, Huaiyin Institute of Technology, Huaian, Jiangsu Province, PR China
| | - Muhammad Bilal
- School of Life Science and Food Engineering, Huaiyin Institute of Technology, Huaian, 223003, China.
| | - Yong Yang
- Key Laboratory of Regional Resource Exploitation and Medicinal Research, Faculty of Chemical Engineering, Huaiyin Institute of Technology, Huaian, Jiangsu Province, PR China
| | - Adnan Khan
- Institute of Chemical Sciences, University of Peshawar, Khyber Pakhtunkhwa, 25120, Pakistan
| | - Farman Ali
- Department of Chemistry, Hazara University, KPK, Mansehra, 21300, Pakistan
| | - Shafiul Karim
- Key Laboratory of Regional Resource Exploitation and Medicinal Research, Faculty of Chemical Engineering, Huaiyin Institute of Technology, Huaian, Jiangsu Province, PR China
| | - Cao Zhou
- Key Laboratory of Regional Resource Exploitation and Medicinal Research, Faculty of Chemical Engineering, Huaiyin Institute of Technology, Huaian, Jiangsu Province, PR China
| | - Ye Wenjie
- Key Laboratory of Regional Resource Exploitation and Medicinal Research, Faculty of Chemical Engineering, Huaiyin Institute of Technology, Huaian, Jiangsu Province, PR China
| | - Farooq Sher
- Department of Engineering, School of Science and Technology, Nottingham Trent University, Nottingham, NG11 8NS, UK
| | - Hafiz M N Iqbal
- Tecnologico de Monterrey, School of Engineering and Science, Monterrey, 64849, Mexico.
| |
Collapse
|
13
|
Pan W, Wang X, Ma X, Chu Y, Pang S, Chen Y, Guan X, Zou B, Wu Y, Zhou G. Postsynthetic Modification of the Magnetic Zirconium-Organic Framework for Efficient and Rapid Solid-Phase Extraction of DNA. ACS APPLIED MATERIALS & INTERFACES 2021; 13:50309-50318. [PMID: 34652138 DOI: 10.1021/acsami.1c12622] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
In recent years, several approaches have been applied to modify metal-organic frameworks (MOFs) owing to their excellent structural tunability such as higher extraction efficiency than that of primitive crystals. Herein, Zr-based MOFs (UiO-66-NH2) with a suitable size modulated by acetic acid were successfully synthesized for effective DNA extraction. The bonding conformations and adsorption mechanism indicated a high affinity between UiO-66-NH2 and the DNA molecules. Furthermore, Fe3O4 nanoparticles were immobilized on the UiO-66-NH2 surface to allow MOFs with magnetism. The magnetic zirconium-organic framework (MZMOF) retained the intact structure of MOFs and simplified subsequent extraction operations. In the DNA recovery investigation, MZMOF showed high recovery efficiency for both short-stranded DNA (90.4%) and pseudovirus DNA (95.1%). In addition, it showed superior DNA extraction efficiency from plasma (57.6%) and swab preservation solution (86.5%). The prepared MZMOF was employed for highly specific extraction of viral DNA and cfDNA from samples. To further simplify the extraction process, MZMOF was applied to immiscible phase filtration assisted by a surface tension (IFAST) chip for facilitating rapid DNA extraction with sensitive point-of-care testing. The developed MZMOF-based extraction method has significant potential for increasing the demand for rapid and efficient nucleic acid extraction.
Collapse
Affiliation(s)
- Wang Pan
- School of Life Science and Technology, China Pharmaceutical University, Nanjing 210009, China
| | - Xuemei Wang
- School of Pharmacy, Southern Medical University, Guangzhou 510515, China
| | - Xueping Ma
- Department of Clinical Pharmacy, Jinling Hospital, State Key Laboratory of Analytical Chemistry for Life Science & Jiangsu Key Laboratory of Molecular Medicine, Medical School of Nanjing University, Nanjing 210002, China
| | - Ya'nan Chu
- Department of Clinical Pharmacy, Jinling Hospital, State Key Laboratory of Analytical Chemistry for Life Science & Jiangsu Key Laboratory of Molecular Medicine, Medical School of Nanjing University, Nanjing 210002, China
| | - Shuyun Pang
- Department of Clinical Pharmacy, Jinling Hospital, State Key Laboratory of Analytical Chemistry for Life Science & Jiangsu Key Laboratory of Molecular Medicine, Medical School of Nanjing University, Nanjing 210002, China
| | - Yuqiu Chen
- Department of Clinical Pharmacy, Jinling Hospital, State Key Laboratory of Analytical Chemistry for Life Science & Jiangsu Key Laboratory of Molecular Medicine, Medical School of Nanjing University, Nanjing 210002, China
| | - Xiaoxiang Guan
- Department of Oncology, The First Affiliated Hospital of Nanjing Medical University, Nanjing 210029, China
| | - Bingjie Zou
- Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, School of Pharmacy, China Pharmaceutical University, Nanjing 210009, China
| | - Yanzi Wu
- Department of Clinical Pharmacy, Jinling Hospital, State Key Laboratory of Analytical Chemistry for Life Science & Jiangsu Key Laboratory of Molecular Medicine, Medical School of Nanjing University, Nanjing 210002, China
| | - Guohua Zhou
- School of Life Science and Technology, China Pharmaceutical University, Nanjing 210009, China
- Department of Clinical Pharmacy, Jinling Hospital, State Key Laboratory of Analytical Chemistry for Life Science & Jiangsu Key Laboratory of Molecular Medicine, Medical School of Nanjing University, Nanjing 210002, China
- School of Pharmacy, Southern Medical University, Guangzhou 510515, China
| |
Collapse
|
14
|
Yan XT, Zhang Y, Zhou Y, Li GH, Feng XS. Source, Sample Preparation, Analytical and Inhibition Methods of Polycyclic Aromatic Hydrocarbons in Food (Update since 2015). SEPARATION & PURIFICATION REVIEWS 2021. [DOI: 10.1080/15422119.2021.1977321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Affiliation(s)
- Xiao-ting Yan
- School of Pharmacy, China Medical University, Shenyang, China
| | - Yuan Zhang
- School of Pharmacy, China Medical University, Shenyang, China
| | - Yu Zhou
- Department of Pharmacy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Guo-hui Li
- Department of Pharmacy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Xue-song Feng
- School of Pharmacy, China Medical University, Shenyang, China
| |
Collapse
|
15
|
Mañana-López A, Sánchez-Piñero J, Moreda-Piñeiro J, Turnes-Carou I, Muniategui-Lorenzo S, López-Mahía P. Polycyclic aromatic hydrocarbons analysis in tea infusions and tea beverages using membrane assisted solvent extraction. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106278] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
16
|
Barzegar F, Kamankesh M, Mohammadi A. Recent Development in Formation, Toxic Effects, Human Health and Analytical Techniques of Food Contaminants. FOOD REVIEWS INTERNATIONAL 2021. [DOI: 10.1080/87559129.2021.1929303] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Fatemeh Barzegar
- Department of Food Science and Technology, Faculty of Nutrition Science, Food Science and Technology/National Nutrition and Food Technology Research Institute, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Marzieh Kamankesh
- Cellular and Molecular Research Center, Sabzevar University of Medical Sciences, Sabzevar, Iran
| | - Abdorreza Mohammadi
- Department of Food Science and Technology, Faculty of Nutrition Science, Food Science and Technology/National Nutrition and Food Technology Research Institute, Shahid Beheshti University of Medical Sciences, Tehran, Iran
- Food Safety Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
17
|
Baheri T, Yamini Y, Shamsayei M, Tabibpour M. Application of HKUST-1 metal-organic framework as coating for headspace solid-phase microextraction of some addictive drugs. J Sep Sci 2021; 44:2814-2823. [PMID: 33945224 DOI: 10.1002/jssc.202100070] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 04/28/2021] [Accepted: 04/29/2021] [Indexed: 01/31/2023]
Abstract
In the present study, a copper-based metal-organic framework (HKUST-1) was used first time for preconcentration trace amounts of addictive drugs in biological samples. HKUST-1 was synthesized and coated onto the surface of stainless steel wire. The prepared coating was used in headspace solid-phase microextraction method coupled with gas chromatography-mass spectrometry for preconcentration and determination of some addictive drugs in biological fluids. Prepared coating shows good extraction efficiency due to large surface area, and π-π stacking interaction with selected analytes. Under optimum conditions, the method was validated with a reasonable determination coefficient (R2 > 0.9961) and suitable linear dynamic range (0.5-1000 μg L-1 ). Also, the limits of detections were obtained in the range of 0.1-0.4, 0.2-0.6, and 0.4-0.7 μg L-1 for water, urine, and plasma samples, respectively. The limits of quantification of present method were obtained in the range 0.5-1.3, 0.7-1.5, and 1.0-1.9 μg L-1 in water, urine, and plasma samples, respectively. The intra-day and inter-dye single fiber and fiber to fiber relative standard deviations were observed in the range 3.0-13.9% and 3.5-12.3%, respectively. Finally, the present method was applied for the determination of the drugs in biological samples.
Collapse
Affiliation(s)
- Tahmine Baheri
- Department of Chemistry, Tarbiat Modares University, Tehran, Iran
| | - Yadollah Yamini
- Department of Chemistry, Tarbiat Modares University, Tehran, Iran
| | - Maryam Shamsayei
- Department of Chemistry, Tarbiat Modares University, Tehran, Iran
| | - Mahmoud Tabibpour
- Chemistry & Chemical Engineering Research Center of Iran, Tehran, Iran
| |
Collapse
|
18
|
Li YN, Hu YY, Ding L, Zhou DB, Chen WJ. Detection of tetracycline antibiotics in water by dispersive micro-solid phase extraction using Fe 3O 4@[Cu 3(btc) 2] magnetic composite combined with liquid chromatography-tandem mass spectrometry. CHINESE J CHEM PHYS 2021. [DOI: 10.1063/1674-0068/cjcp2004046] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Affiliation(s)
- Yan-ni Li
- Department of Nutrition and Food Hygiene, School of Public Health, Anhui Medical University, Hefei 230032, China
| | - Yan-yun Hu
- Department of Nutrition and Food Hygiene, School of Public Health, Anhui Medical University, Hefei 230032, China
- Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei 230026, China
| | - Lei Ding
- Anhui Province Key Laboratory of Analysis and Detection for Food Safety, Hefei 230022, China
| | - Dian-bing Zhou
- Anhui Province Key Laboratory of Analysis and Detection for Food Safety, Hefei 230022, China
| | - Wen-jun Chen
- Department of Nutrition and Food Hygiene, School of Public Health, Anhui Medical University, Hefei 230032, China
| |
Collapse
|
19
|
Jagirani MS, Soylak M. Review: Microextraction Technique Based New Trends in Food Analysis. Crit Rev Anal Chem 2020; 52:968-999. [PMID: 33253048 DOI: 10.1080/10408347.2020.1846491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Food chemistry is the study and classification of the quality and origin of foods. The identification of definite biomarkers and the determination of residue contaminants such as toxins, pesticides, metals, human and veterinary drugs, which are a very common source of food-borne diseases. The food analysis is continuously demanding the improvement of more robust, sensitive, highly efficient, and economically beneficial analytical approaches to promise the traceability, safety, and quality of foods in the acquiescence with the consumers and legislation demands. The traditional methods have been used at the starting of the 20th century based on wet chemical methods. Now it existing the powerful analytical techniques used in food analysis and safety. This development has led to substantial enhancements in the analytical accuracy, precision, sensitivity, selectivity, thereby mounting the applied range of food applications. In the present decade, microextraction (micro-scale extraction) pays more attention due to its futures such as low consumption of solvent and sample, throughput analysis easy to operate, greener, robotics, and miniaturization, different adsorbents have been used in the microextraction process with unique nature recognized with wide range applications.
Collapse
Affiliation(s)
- Muhammed Saqaf Jagirani
- Faculty of Sciences, Department of Chemistry, Erciyes University, Kayseri, Turkey.,National Center of Excellence in Analytical Chemistry, University of Sindh, Sindh, Pakistan
| | - Mustafa Soylak
- Faculty of Sciences, Department of Chemistry, Erciyes University, Kayseri, Turkey.,Technology Research and Application Center (TAUM), Erciyes University, Kayseri, Turkey
| |
Collapse
|
20
|
Yang J, Wang Y, Pan M, Xie X, Liu K, Hong L, Wang S. Synthesis of Magnetic Metal-Organic Frame Material and Its Application in Food Sample Preparation. Foods 2020; 9:E1610. [PMID: 33172006 PMCID: PMC7694616 DOI: 10.3390/foods9111610] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2020] [Revised: 10/30/2020] [Accepted: 11/03/2020] [Indexed: 12/15/2022] Open
Abstract
A variety of contaminants in food is an important aspect affecting food safety. Due to the presence of its trace amounts and the complexity of food matrix, it is very difficult to effectively separate and accurately detect them. The magnetic metal-organic framework (MMOF) composites with different structures and functions provide a new choice for the purification of food matrix and enrichment of trace targets, thus providing a new direction for the development of new technologies in food safety detection with high sensitivity and efficiency. The MOF materials composed of inorganic subunits and organic ligands have the advantages of regular pore structure, large specific surface area and good stability, which have been thoroughly studied in the pretreatment of complex food samples. MMOF materials combined different MOF materials with various magnetic nanoparticles, adding magnetic characteristics to the advantages of MOF materials, which are in terms of material selectivity, biocompatibility, easy operation and repeatability. Combined with solid phase extraction (SPE) technique, MMOF materials have been widely used in the food pretreatment. This article introduced the new preparation strategies of different MMOF materials, systematically summarizes their applications as SPE adsorbents in the pretreatment of food contaminants and analyzes and prospects their future application prospects and development directions.
Collapse
Affiliation(s)
- Jingying Yang
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; (J.Y.); (Y.W.); (M.P.); (X.X.); (K.L.); (L.H.)
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Yabin Wang
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; (J.Y.); (Y.W.); (M.P.); (X.X.); (K.L.); (L.H.)
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Mingfei Pan
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; (J.Y.); (Y.W.); (M.P.); (X.X.); (K.L.); (L.H.)
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Xiaoqian Xie
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; (J.Y.); (Y.W.); (M.P.); (X.X.); (K.L.); (L.H.)
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Kaixin Liu
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; (J.Y.); (Y.W.); (M.P.); (X.X.); (K.L.); (L.H.)
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Liping Hong
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; (J.Y.); (Y.W.); (M.P.); (X.X.); (K.L.); (L.H.)
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China
| | - Shuo Wang
- State Key Laboratory of Food Nutrition and Safety, Tianjin University of Science and Technology, Tianjin 300457, China; (J.Y.); (Y.W.); (M.P.); (X.X.); (K.L.); (L.H.)
- Key Laboratory of Food Nutrition and Safety, Ministry of Education of China, Tianjin University of Science and Technology, Tianjin 300457, China
| |
Collapse
|
21
|
Khan WA, Arain MB, Soylak M. Nanomaterials-based solid phase extraction and solid phase microextraction for heavy metals food toxicity. Food Chem Toxicol 2020; 145:111704. [DOI: 10.1016/j.fct.2020.111704] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 08/10/2020] [Accepted: 08/19/2020] [Indexed: 12/25/2022]
|
22
|
Ghorbani M, Aghamohammadhassan M, Ghorbani H, Zabihi A. Trends in sorbent development for dispersive micro-solid phase extraction. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105250] [Citation(s) in RCA: 53] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
23
|
Sajid M, Nazal MK, Ihsanullah I. Novel materials for dispersive (micro) solid-phase extraction of polycyclic aromatic hydrocarbons in environmental water samples: A review. Anal Chim Acta 2020; 1141:246-262. [PMID: 33248658 DOI: 10.1016/j.aca.2020.07.064] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Revised: 07/24/2020] [Accepted: 07/24/2020] [Indexed: 11/29/2022]
Abstract
Polycyclic aromatic hydrocarbons are hazardous environmental pollutants that possess mutagenic and carcinogenic properties. Generally, the concentrations of PAHs in environmental water samples are very low, and it is challenging to detect such levels directly by the analytical instrumentation. Thus, the extraction of PAHs using suitable extraction methodology is required for sample cleanup and analyte enrichment. Dispersive solid-phase extraction has several advantages over conventional approaches for the extraction of PAHs from environmental water samples. In this article, we critically evaluate the role of different nano and micro sorbent materials employed in the extraction of PAHs. Carbon-based nanomaterials, metal-organic frameworks, polymeric nanocomposites, ionic-liquid based composites, and silica-based materials are explicitly covered. This review also provides insight on functional components of all types of sorbents and their way of interaction with PAHs. The factors affecting the dispersive (micro) solid phase extraction of PAHs such as the design of the sorbent, the ratio of functional material to magnetic core, sample volume, amount of sorbent, extraction and desorption times, desorption solvent and its volume, salt addition, and sample pH are critically appraised. Finally, a brief account on the accomplishments, limitations, and challenges associated with such methods is provided.
Collapse
Affiliation(s)
- Muhammad Sajid
- Center for Environment and Water, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran, 31261, Saudi Arabia.
| | - Mazen Khaled Nazal
- Center for Environment and Water, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran, 31261, Saudi Arabia
| | - Ihsanullah Ihsanullah
- Center for Environment and Water, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran, 31261, Saudi Arabia
| |
Collapse
|
24
|
Du KZ, Sun AL, Yan C, Liang C, Qi L, Wang C, Yang R, Cui Y, Shang Y, Li J, Chang YX. Recent advances of green pretreatment techniques for quality control of natural products. Electrophoresis 2020; 41:1469-1481. [PMID: 32524626 DOI: 10.1002/elps.202000084] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 05/14/2020] [Accepted: 05/28/2020] [Indexed: 12/16/2022]
Abstract
A few advancing technologies for natural product analysis have been widely proposed, which focus on decreasing energy consumption and developing an environmentally sustainable manner. These green sample pretreatment and analysis methods following the green Analytical Chemistry (GAC) criteria have the advantage of improving the strategy of chemical analyses, promoting sustainable development to analytical laboratories, and reducing the negative effects of analysis experiments on the environment. A few minimized extraction methodologies have been proposed for replacing the traditional methods in the quality evaluation of natural products, mainly including solid-phase microextraction (SPME) and liquid phase microextraction (LPME). These procedures not only have no need for large numbers of samples and toxic reagent, but also spend a small amount of extraction and analytical time. This overview aims to list out the main green strategies on the application of quality evaluation and control for natural products in the past 3 years.
Collapse
Affiliation(s)
- Kun-Ze Du
- Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China.,Tianjin Key Laboratory of Phytochemistry and Pharmaceutical Analysis, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China
| | - A-Li Sun
- Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China.,Tianjin Key Laboratory of Phytochemistry and Pharmaceutical Analysis, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China
| | - Chaozhuo Yan
- Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China.,Tianjin Key Laboratory of Phytochemistry and Pharmaceutical Analysis, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China
| | - Chunxiao Liang
- Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China.,Tianjin Key Laboratory of Phytochemistry and Pharmaceutical Analysis, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China
| | - Lina Qi
- Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China.,Tianjin Key Laboratory of Phytochemistry and Pharmaceutical Analysis, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China
| | - Chenhong Wang
- Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China.,Tianjin Key Laboratory of Phytochemistry and Pharmaceutical Analysis, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China
| | - Rui Yang
- Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China.,Tianjin Key Laboratory of Phytochemistry and Pharmaceutical Analysis, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China
| | - Yan Cui
- Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China.,Tianjin Key Laboratory of Phytochemistry and Pharmaceutical Analysis, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China
| | - Ye Shang
- Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China.,Tianjin Key Laboratory of Phytochemistry and Pharmaceutical Analysis, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China
| | - Jin Li
- Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China
| | - Yan-Xu Chang
- Tianjin State Key Laboratory of Modern Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China.,Tianjin Key Laboratory of Phytochemistry and Pharmaceutical Analysis, Tianjin University of Traditional Chinese Medicine, Tianjin, P. R. China
| |
Collapse
|
25
|
Impact of the Preparation Procedure on the Performance of the Microporous HKUST-1 Metal-Organic Framework in the Liquid-Phase Separation of Aromatic Compounds. Molecules 2020; 25:molecules25112648. [PMID: 32517274 PMCID: PMC7321157 DOI: 10.3390/molecules25112648] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2020] [Revised: 06/02/2020] [Accepted: 06/03/2020] [Indexed: 11/29/2022] Open
Abstract
To date, metal-organic frameworks (MOFs) have been recognized as promising solid phases in high-performance liquid chromatography (HPLC). This research aimed to elucidate the role of the physico-chemical characteristics of the microporous HKUST-1 metal-organic framework in its operation as a selective adsorbent in HPLC. For this, the HKUST-1 samples were prepared by microwave-assisted synthesis and a solvothermal procedure. According to the chromatographic examinations, the HKUST-1 material synthesized in the microwave fields shows an efficient performance in the selective adsorption of aromatic compounds with different functionalities. This study revealed a significant impact of the preparation procedure on the mechanism of the liquid-phase adsorption on the HKUST adsorbents under conditions of the HPLC. An effect of the elution solvent with the different coordination ability to the Cu2+ sites in the HKUST-1 structure on the adsorption selectivity was observed.
Collapse
|
26
|
|
27
|
Boontongto T, Burakham R. Simple magnetization of Fe 3 O 4 /MIL-53(Al)-NH 2 for a rapid vortex-assisted dispersive magnetic solid-phase extraction of phenol residues in water samples. J Sep Sci 2020; 43:3083-3092. [PMID: 32445251 DOI: 10.1002/jssc.202000426] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 05/17/2020] [Accepted: 05/18/2020] [Indexed: 12/17/2022]
Abstract
The present work describes a simple route to magnetize MIL-53(Al)-NH2 sorbent for rapid extraction of phenol residues from environmental samples. To extend the applications and performances of the metal-organic frameworks in the field of adsorption materials, we combined the properties of metal-organic frameworks and magnetite to decrease the extraction time and simplify the extraction process as well. In this study, a simple and quick vortex-assisted dispersive magnetic solid phase extraction method for the extraction of ten United States Environmental Protection Agency's priority phenols from water samples prior to analysis by high-performance liquid chromatography with photodiode array detection was proposed. The developed method exhibits a rapid enrichment of the target analytes within 10 s for extraction and 10 s for desorption. Low detection limits of 1.8-41.7 µg/L and quantitation limits of 6.0-139.0 µg/L with the relative standard deviations for intra- and interday analyses less than 12% were achieved. Satisfactory recoveries in the range of 80-111% with the relative standard deviations less than 11% demonstrated that Fe3 O4 /MIL-53(Al)-NH2 is promising sorbent in the field of magnetic solid-phase extraction for environmental samples.
Collapse
Affiliation(s)
- Tittaya Boontongto
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, Thailand
| | - Rodjana Burakham
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, Thailand
| |
Collapse
|
28
|
Zhang Q, Liu P, Li S, Zhang X, Chen M. Progress in the analytical research methods of polycyclic aromatic hydrocarbons (PAHs). J LIQ CHROMATOGR R T 2020. [DOI: 10.1080/10826076.2020.1746668] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Affiliation(s)
- Qiongyao Zhang
- Department of Hygiene Detection, College of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, P.R. China
| | - Ping Liu
- Department of Hygiene Detection, College of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, P.R. China
| | - Shuling Li
- Department of Hygiene Detection, College of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, P.R. China
| | - Xuejiao Zhang
- Department of Hygiene Detection, College of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, P.R. China
| | - Mengdi Chen
- Department of Hygiene Detection, College of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, P.R. China
| |
Collapse
|
29
|
Magnetic Cu: CuO-GO nanocomposite for efficient dispersive micro-solid phase extraction of polycyclic aromatic hydrocarbons from vegetable, fruit, and environmental water samples by liquid chromatographic determination. Talanta 2020; 218:121131. [PMID: 32797888 DOI: 10.1016/j.talanta.2020.121131] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2020] [Revised: 05/04/2020] [Accepted: 05/05/2020] [Indexed: 12/19/2022]
Abstract
In this research, we presented a magnetic dispersive micro-solid phase extraction (MD-μ-SPE) method coupled with high performance liquid chromatography (HPLC) based on the use of magnetic Cu: CuO-Graphene Oxide (GO) nanocomposite (Fe3O4/Cu: CuO/GO-NC) for the separation and preconcentration of polycyclic aromatic hydrocarbons (PAHs), i.e. naphthalene (Nap), phenanthrene (Phe), anthracene (Ant), and pyrene (Pyr), in vegetable (onion, tomato, carrot, herb, watermelon, lettuce, eggplant, and chili pepper), fruit (apple, watermelon, and grape), wastewater, and water samples. The MD-μ-SPE of PAHs in matrix samples was carried out, and the impacts of pH, ionic strength, extraction time, temperature, eluent volume, and sorbent mass on the recovery of PAHs were investigated by using Placket-Burman design (PBD). In addition, by using the central composite design (CCD), the best combination of each important variable was measured. Sorbent mass of 14 mg, eluent volume of 200 μL, and 12 min extraction time at the central level of other factors were optimal conditions of pretreatment for the highest extraction recovery (ER%) of trace PAHs. Under the optimal conditions, the method proposed herein provided high enrichment factors ranged from 116.51 to 133.05, good linearity in the range of 10-3800 ng mL-1 for Pyr, 3.0-3500 ng mL-1 for Phe, 5.0-3200 ng mL-1 for Nap, and 5.0-3000 ng mL-1 for Ant with coefficient of determination (R2) values between 0.9889 and 0.9963, low limits of detection (LOD) and quantification (LOQ) in the range of 0.015-0.061 and 0.485-2.034 ng mL-1, respectively, and also satisfactory spiked recoveries (between 95.1% and 106.8%) with the relative standard deviations (RSDs) values in the range of 1.73%-5.62%. The Fe3O4/Cu: CuO/GO-NC-based MD-μ-SPE followed by HPLC-UV corroborated promising results for the convenient and effective determination of PAHs in the samples of vegetables, fruits, and environmental water. The results of this study revealed that our developed method is easy, feasible, precise, highly effective, and convenient to operate for the trace analysis of PAHs in different real samples. The extraction recovery was about 90% of the initial recovery after the sorbent usage for three times; therefore, the Fe3O4/Cu: CuO/GO-NC can readily be regenerated.
Collapse
|
30
|
Manousi N, Zachariadis GA. Recent Advances in the Extraction of Polycyclic Aromatic Hydrocarbons from Environmental Samples. Molecules 2020; 25:E2182. [PMID: 32392764 PMCID: PMC7249015 DOI: 10.3390/molecules25092182] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 05/01/2020] [Accepted: 05/04/2020] [Indexed: 02/07/2023] Open
Abstract
Polycyclic aromatic hydrocarbons (PAHs) comprise a group of chemical compounds consisting of two or more fused benzene rings. PAHs exhibit hydrophobicity and low water solubility, while some of their members are toxic substances resistant to degradation. Due to their low levels in environmental matrices, a preconcentration step is usually required for their determination. Nowadays, there is a wide variety of sample preparation techniques, including micro-extraction techniques (e.g., solid-phase microextraction and liquid phase microextraction) and miniaturized extraction techniques (e.g., dispersive solid-phase extraction, magnetic solid-phase extraction, stir bar sorptive extraction, fabric phase sorptive extraction etc.). Compared to the conventional sample preparation techniques, these novel techniques show some benefits, including reduced organic solvent consumption, while they are time and cost efficient. A plethora of adsorbents, such as metal-organic frameworks, carbon-based materials and molecularly imprinted polymers, have been successfully coupled with a wide variety of extraction techniques. This review focuses on the recent advances in the extraction techniques of PAHs from environmental matrices, utilizing novel sample preparation approaches and adsorbents.
Collapse
Affiliation(s)
- Natalia Manousi
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| | - George A. Zachariadis
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece
| |
Collapse
|
31
|
Jinadasa BKKK, Monteau F, Morais S. Critical review of micro-extraction techniques used in the determination of polycyclic aromatic hydrocarbons in biological, environmental and food samples. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2020; 37:1004-1026. [PMID: 32186468 DOI: 10.1080/19440049.2020.1733103] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Polycyclic Aromatic Hydrocarbons (PAHs) are ubiquitous environmental contaminants and their accurate determination is very important to human health and environment safety. In this review, sorptive-based micro-extraction techniques [such as Solid-Phase Micro-extraction (SPME), Stir Bar Sorptive Extraction (SBSE), Micro-extraction in Packed Sorbent (MEPS)] and solvent-based micro-extraction [Membrane-Mediated Liquid-Phase Micro-extraction (MM-LPME), Dispersive Liquid-Liquid Micro-extraction (DLLME), and Single Drop Micro-extraction (SDME)] developed for quantification of PAHs in environmental, biological and food samples are reviewed. Moreover, recent micro-extraction techniques that have been coupled with other sample extraction strategies are also briefly discussed. The main objectives of these micro-extraction techniques are to perform extraction, pre-concentration and clean up together as one step, and the reduction of the analysis time, cost and solvent following the green chemistry guidelines.
Collapse
Affiliation(s)
- B K K K Jinadasa
- Laboratoire D'étude Des Résidus Et Contaminants Dans Les Aliments (LABERCA), Nantes-Atlantic National College of Veterinary Medicine, Food Science, and Engineering (ONIRIS) , Nantes, France
| | - Fabrice Monteau
- Laboratoire D'étude Des Résidus Et Contaminants Dans Les Aliments (LABERCA), Nantes-Atlantic National College of Veterinary Medicine, Food Science, and Engineering (ONIRIS) , Nantes, France
| | - Simone Morais
- REQUIMTE-LAQV, Instituto Superior De Engenharia Do Porto, Instituto Politécnico Do Porto , Porto, Portugal
| |
Collapse
|
32
|
Toledo-Jaldin HP, Sánchez-Mendieta V, Blanco-Flores A, López-Téllez G, Vilchis-Nestor AR, Martín-Hernández O. Low-cost sugarcane bagasse and peanut shell magnetic-composites applied in the removal of carbofuran and iprodione pesticides. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2020; 27:7872-7885. [PMID: 31889281 DOI: 10.1007/s11356-019-07089-4] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Accepted: 11/18/2019] [Indexed: 06/10/2023]
Abstract
In the present study, two agro-industrial wastes, sugarcane bagasse, and peanut shell were employed as support of magnetite nanoparticles for the synthesis of magnetic bio-composites: magnetic sugarcane bagasse (MBO) and magnetic peanut shell (MPSo). The presence of magnetite was verified by Raman spectroscopy. Magnetic nanoparticles shape and size distribution were studied by TEM, while composites morphologies were observed by SEM. Structural characteristics of the pesticides and their possible chemical adsorption on composites were analyzed by FTIR. The removal was carried out by a batch adsorption process, and UV-VIS technique was used for pesticide concentration estimation. Elovich model described better all systems pointing out to a chemical adsorption process occurring. Experimental data isotherms of carbofuran and iprodione can be best explained by more than one mathematical model, but Sip was the ordinary equation in all systems. Maximum adsorption capacities of 175 and 89.3 mg/g for carbofuran, and 119 and 2.76 mg/g for iprodione, were obtained for MBo and MPSo, respectively.
Collapse
Affiliation(s)
- Helen Paola Toledo-Jaldin
- Posgrado en Ciencia de Materiales, Facultad de Química, Universidad Autónoma del Estado de México Paseo Colón y Tollocan, 50110, Toluca, México, Mexico
- Centro Conjunto de Investigación en Química Sustentable UAEM-UNAM, (CCIQS), Carretera Toluca-Atlacomulco Km 14.5, Unidad El Rosedal C.P., 50200, Toluca, Estado de México, Mexico
| | - Víctor Sánchez-Mendieta
- Centro Conjunto de Investigación en Química Sustentable UAEM-UNAM, (CCIQS), Carretera Toluca-Atlacomulco Km 14.5, Unidad El Rosedal C.P., 50200, Toluca, Estado de México, Mexico
| | - Alien Blanco-Flores
- Tecnológico de Estudios Superiores de Tianguistenco, División de Ingeniería Mecánica, Carretera Tenango-La Marqueza km 22, Santiago Tilapa, C.P., 52650, Santiago de Tianguistenco, Mexico.
| | - Gustavo López-Téllez
- Centro Conjunto de Investigación en Química Sustentable UAEM-UNAM, (CCIQS), Carretera Toluca-Atlacomulco Km 14.5, Unidad El Rosedal C.P., 50200, Toluca, Estado de México, Mexico.
| | - Alfredo Rafael Vilchis-Nestor
- Centro Conjunto de Investigación en Química Sustentable UAEM-UNAM, (CCIQS), Carretera Toluca-Atlacomulco Km 14.5, Unidad El Rosedal C.P., 50200, Toluca, Estado de México, Mexico
| | - Osnieski Martín-Hernández
- Síntesis y Formulaciones de Alta Tecnología, S.A. De C.V. (SIFATEC), Álamo 101, Habitacional Valle de Los Pinos 2a. Sección, 54040, Tlalnepantla, Mexico
| |
Collapse
|
33
|
Qin SB, Li XS, Fan YH, Mou XX, Qi SH. Facile synthesis of polydivinylbenzene coated magnetic polydopamine coupled with pressurized liquid extraction for the extraction and cleanup of polycyclic aromatic hydrocarbons in soils. J Chromatogr A 2020; 1613:460676. [PMID: 31727351 DOI: 10.1016/j.chroma.2019.460676] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 09/20/2019] [Accepted: 11/03/2019] [Indexed: 01/03/2023]
Abstract
Due to the trace levels of polycyclic aromatic hydrocarbons (PAHs) in soil and the complexity of soil matrices, effective sample pretreatment methods are of great significance to obtain accurate analytical results. In this paper, polydopamine (PDA) encapsulated Fe3O4 particles were used as seeds for in situ polymerization of divinylbenzene (DVB) to derive magnetic hybrid material Fe3O4@PDA@PDVB. Coupled with pressurized liquid extraction, Fe3O4@PDA@PDVB was investigated as a selective adsorbent for the extraction and cleanup of PAHs in soil. The prepared magnetic material was characterized and demonstrated to possess strong hydrophobicity and superparamagnetism. Under optimal conditions, Fe3O4@PDA@PDVB can effectively extract 15 PAHs from a 30% methanol solution within 2 min, and it is more selective for PAHs than for n-alkane in soil extracts. The matrix effect significantly decreased after extraction by the prepared material, which showed superiority to a silica gel column method (EPA 3630C Method). The developed method was linear (5-1000 ng g-1) with coefficient of determination (R2) ranging from 0.9986-0.9998, and the limits of detection were 0.13-0.54 ng g-1. Additionally, repetitive experiments indicated that the prepared material was reproducible and reusable with relative standard deviations below 8.4% and 8.6%, respectively. Finally, the new method was successfully employed to determine the concentrations of PAHs in genuine soil and standard reference material, and the results were comparable to those of widely utilized EPA methodology.
Collapse
Affiliation(s)
- Shi-Bin Qin
- State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan 430074, China
| | - Xiao-Shui Li
- State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan 430074, China.
| | - Yu-Han Fan
- State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan 430074, China
| | - Xiao-Xuan Mou
- State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan 430074, China
| | - Shi-Hua Qi
- State Key Laboratory of Biogeology and Environmental Geology, China University of Geosciences, Wuhan 430074, China.
| |
Collapse
|
34
|
Metal organic framework composite, nano-Fe3O4@Fe-(benzene-1,3,5-tricarboxylic acid), for solid phase extraction of blood lipid regulators from water. Talanta 2020; 207:120275. [DOI: 10.1016/j.talanta.2019.120275] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Revised: 08/13/2019] [Accepted: 08/15/2019] [Indexed: 11/24/2022]
|
35
|
Shi Z, Jiang J, Pang W, Ma H, Chu X, Zhou C, Zhang H. Dispersive micro-solid phase extraction using cotton based carbon fiber sorbent for the determination of three polycyclic aromatic hydrocarbons in tea infusion by gas chromatography-quadrupole mass spectrometry. Microchem J 2019. [DOI: 10.1016/j.microc.2019.104209] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
36
|
Recent advances in emerging nanomaterials based food sample pretreatment methods for food safety screening. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.115669] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
37
|
Hamidi S, Taghvimi A, Mazouchi N. Micro Solid Phase Extraction Using Novel Adsorbents. Crit Rev Anal Chem 2019; 51:103-114. [DOI: 10.1080/10408347.2019.1684235] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Samin Hamidi
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Arezou Taghvimi
- Biotechnology Research Centre and Student Research Committee, Tabriz University of Medical Science, Tabriz, Iran
| | - Negin Mazouchi
- Pharmaceutical Analysis Research Center, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
38
|
Simple and effective dispersive micro-solid phase extraction procedure for simultaneous determination of polycyclic aromatic compounds in fresh and marine waters. Talanta 2019; 204:776-791. [DOI: 10.1016/j.talanta.2019.06.061] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2019] [Revised: 06/14/2019] [Accepted: 06/15/2019] [Indexed: 11/20/2022]
|
39
|
Ma YJ, Jiang XX, Lv YK. Recent Advances in Preparation and Applications of Magnetic Framework Composites. Chem Asian J 2019; 14:3515-3530. [DOI: 10.1002/asia.201901139] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2019] [Revised: 09/18/2019] [Indexed: 12/23/2022]
Affiliation(s)
- Yao Jia Ma
- College of Chemistry and Environmental ScienceHebei University Baoding 071002 China
| | - Xiao Xue Jiang
- College of Chemistry and Environmental ScienceHebei University Baoding 071002 China
| | - Yun Kai Lv
- College of Chemistry and Environmental ScienceHebei University Baoding 071002 China
| |
Collapse
|
40
|
Yu M, Wang L, Hu L, Li Y, Luo D, Mei S. Recent applications of magnetic composites as extraction adsorbents for determination of environmental pollutants. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.07.022] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
|
41
|
|
42
|
Wang PL, Xie LH, Joseph EA, Li JR, Su XO, Zhou HC. Metal-Organic Frameworks for Food Safety. Chem Rev 2019; 119:10638-10690. [PMID: 31361477 DOI: 10.1021/acs.chemrev.9b00257] [Citation(s) in RCA: 289] [Impact Index Per Article: 48.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Food safety is a prevalent concern around the world. As such, detection, removal, and control of risks and hazardous substances present from harvest to consumption will always be necessary. Metal-organic frameworks (MOFs), a class of functional materials, possess unique physical and chemical properties, demonstrating promise in food safety applications. In this review, the synthesis and porosity of MOFs are first introduced by some representative examples that pertain to the field of food safety. Following that, the application of MOFs and MOF-based materials in food safety monitoring, food processing, covering preservation, sanitation, and packaging is overviewed. Future perspectives, as well as potential opportunities and challenges faced by MOFs in this field will also be discussed. This review aims to promote the development and progress of MOF chemistry and application research in the field of food safety, potentially leading to novel solutions.
Collapse
Affiliation(s)
- Pei-Long Wang
- Institute of Quality Standards and Testing Technology for Agro-products , Chinese Academy of Agricultural Sciences , Beijing 100081 , P. R. China.,Beijing Key Laboratory for Green Catalysis and Separation and Department of Chemistry and Chemical Engineering, College of Environmental and Energy Engineering , Beijing University of Technology , Beijing 100124 , P. R. China
| | - Lin-Hua Xie
- Beijing Key Laboratory for Green Catalysis and Separation and Department of Chemistry and Chemical Engineering, College of Environmental and Energy Engineering , Beijing University of Technology , Beijing 100124 , P. R. China
| | - Elizabeth A Joseph
- Department of Chemistry , Texas A&M University , P.O. Box 30012, College Station , Texas 77842-3012 , United States
| | - Jian-Rong Li
- Beijing Key Laboratory for Green Catalysis and Separation and Department of Chemistry and Chemical Engineering, College of Environmental and Energy Engineering , Beijing University of Technology , Beijing 100124 , P. R. China
| | - Xiao-Ou Su
- Institute of Quality Standards and Testing Technology for Agro-products , Chinese Academy of Agricultural Sciences , Beijing 100081 , P. R. China
| | - Hong-Cai Zhou
- Department of Chemistry , Texas A&M University , P.O. Box 30012, College Station , Texas 77842-3012 , United States
| |
Collapse
|
43
|
Maya F, Ghani M. Ordered macro/micro-porous metal-organic framework of type ZIF-8 in a steel fiber as a sorbent for solid-phase microextraction of BTEX. Mikrochim Acta 2019; 186:425. [DOI: 10.1007/s00604-019-3560-0] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Accepted: 05/27/2019] [Indexed: 12/27/2022]
|
44
|
Magnetic nanoparticles modified with hyperbranched polyamidoamine for the extraction of benzoylurea insecticides prior to their quantitation by HPLC. Mikrochim Acta 2019; 186:351. [DOI: 10.1007/s00604-019-3450-5] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Accepted: 04/15/2019] [Indexed: 11/27/2022]
|
45
|
Recent Advances and Trends in Applications of Solid-Phase Extraction Techniques in Food and Environmental Analysis. Chromatographia 2019. [DOI: 10.1007/s10337-019-03726-9] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
46
|
Farajzadeh MA, Yadeghari A, Abbaspour M. Dispersive Solid Phase Extraction Using Magnetic Nanoparticles Performed in a Narrow-Bored Tube for Extraction of Atorvastatin, Losartan, and Valsartan in Plasma. Adv Pharm Bull 2019; 9:138-146. [PMID: 31011568 PMCID: PMC6468226 DOI: 10.15171/apb.2019.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2018] [Revised: 10/24/2018] [Accepted: 11/12/2018] [Indexed: 12/04/2022] Open
Abstract
Purpose: In this investigation, a new version of magnetic solid phase extraction (MSPE) performed
in a narrow–bore tube has been proposed. In this study, hydrophobic octyl (C8) functionalized
Fe3O4 magnetic nanoparticles (MNPs) stabilized by SiOH groups (Fe3O4@SiO2@C8) are used as
magnetic nano–sorbents for the extraction of cardiovascular drugs from human plasma prior to
their determination by high performance liquid chromatography–photodiode array detection.
Methods: After precipitation of the plasma proteins, the supernatant is diluted with deionized
water and filled into the narrow–bore tube. Then mg–level of the sorbent is added into the tube.
The sorbent is dispersed and moved down through the solution instead of passing the solution
from the cartridge. Using an external magnet, the collected nano–sorbents at the bottom of the
tube are transferred on top of the solution and released to move down through the solution for
three times to increase the extraction efficiency.
Results: The linearity of the assay was ranging from 0.4–500 mg mL-1. The limits of detection
and quantification of the method were obtained in the ranges of 0.05–0.07 and 0.16–0.24 mg
L-1, respectively. The extraction recoveries were obtained in the range of 31–49%. Intra– and
inter–day precisions were calculated and obtained in the ranges of 5–8 and 7%–9% for 0.5 mg
L-1 of each analyte, and 5–6 and 6%–8% for 2 mg L-1 of each analyte, respectively.
Conclusion: The proposed method was successfully used in determination of the studied drugs
in patient’s plasmas.
Collapse
Affiliation(s)
- Mir Ali Farajzadeh
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.,Engineering Faculty, Near East University, 99138 Nicosia, North Cyprus, Mersin 10, Turkey
| | - Adeleh Yadeghari
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | - Maryam Abbaspour
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| |
Collapse
|
47
|
Lahtinen E, Precker RLM, Lahtinen M, Hey-Hawkins E, Haukka M. Selective Laser Sintering of Metal-Organic Frameworks: Production of Highly Porous Filters by 3D Printing onto a Polymeric Matrix. Chempluschem 2019; 84:222-225. [PMID: 31950695 DOI: 10.1002/cplu.201900081] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Revised: 02/07/2019] [Indexed: 12/19/2022]
Abstract
Metal-organic frameworks (MOFs) have raised a lot of interest, especially as adsorbing materials, because of their unique and well-defined pore structures. One of the main challenges in the utilization of MOFs is their crystalline and powdery nature, which makes their use inconvenient in practice. Three-dimensional printing has been suggested as a potential solution to overcome this problem. We used selective laser sintering (SLS) to print highly porous flow-through filters containing the MOF copper(II) benzene-1,3,5-tricarboxylate (HKUST-1). These filters were printed simply by mixing HKUST-1 with an easily printable nylon-12 polymer matrix. By using the SLS, powdery particles were fused together in such a way that the structure of the printed solid material resembles the structure of a powder bed. The MOF additive is firmly attached only on the surface of partially fused polymer particles and therefore remains accessible to fluids passing through the filter. Powder X-ray analysis of the printed object confirmed that printing did not have any negative impact on the structure of the MOF. CO2 -adsorption studies also showed that the activity of the MOF was not affected by the printing process. SLS offers a straightforward and easy way to fabricate tailor-made MOF-containing filters for practical applications.
Collapse
Affiliation(s)
- Elmeri Lahtinen
- Department of Chemistry, University of Jyväskylä, P.O. Box 35, FIN-40014, Jyväskylä, Finland
| | - Rafaella L M Precker
- Faculty of Chemistry and Mineralogy Institute of Inorganic Chemistry, Leipzig University, Johannisallee, 29, 04103, Leipzig, Germany
| | - Manu Lahtinen
- Department of Chemistry, University of Jyväskylä, P.O. Box 35, FIN-40014, Jyväskylä, Finland
| | - Evamarie Hey-Hawkins
- Faculty of Chemistry and Mineralogy Institute of Inorganic Chemistry, Leipzig University, Johannisallee, 29, 04103, Leipzig, Germany
| | - Matti Haukka
- Department of Chemistry, University of Jyväskylä, P.O. Box 35, FIN-40014, Jyväskylä, Finland
| |
Collapse
|
48
|
González-Hernández P, Lago AB, Pasán J, Ruiz-Pérez C, Ayala JH, Afonso AM, Pino V. Application of a Pillared-Layer Zn-Triazolate Metal-Organic Framework in the Dispersive Miniaturized Solid-Phase Extraction of Personal Care Products from Wastewater Samples. Molecules 2019; 24:E690. [PMID: 30769919 PMCID: PMC6412874 DOI: 10.3390/molecules24040690] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Revised: 01/28/2019] [Accepted: 02/11/2019] [Indexed: 11/16/2022] Open
Abstract
The pillared-layer Zn-triazolate metal-organic framework (CIM-81) was synthesized, characterized, and used for the first time as a sorbent in a dispersive micro-solid phase extraction method. The method involves the determination of a variety of personal care products in wastewaters, including four preservatives, four UV-filters, and one disinfectant, in combination with ultra-high performance liquid chromatography and UV detection. The CIM-81 MOF, constructed with an interesting mixed-ligand synthetic strategy, demonstrated a better extraction performance than other widely used MOFs in D-µSPE such as UiO-66, HKUST-1, and MIL-53(Al). The optimization of the method included a screening design followed by a Doehlert design. Optimum conditions required 10 mg of CIM-81 MOF in 10 mL of the aqueous sample at a pH of 5, 1 min of agitation by vortex and 3 min of centrifugation in the extraction step; and 1.2 mL of methanol and 4 min of vortex in the desorption step, followed by filtration, evaporation and reconstitution with 100 µL of the initial chromatographic mobile phase. The entire D-µSPE-UHPLC-UV method presented limits of detection down to 0.5 ng·mL-1; intra-day and inter-day precision values for the lowest concentration level (15 ng·mL-1)-as a relative standard deviation (in %)-lower than 8.7 and 13%, respectively; average relative recovery values of 115%; and enrichment factors ranging from ~3.6 to ~34. The reuse of the CIM-81 material was assessed not only in terms of maintaining the analytical performance but also in terms of its crystalline stability.
Collapse
Affiliation(s)
- Providencia González-Hernández
- Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), La Laguna, Tenerife 38206, Spain.
| | - Ana B Lago
- Laboratorio de Rayos X y Materiales Moleculares (MATMOL), Departamento de Física, Universidad de La Laguna (ULL), La Laguna, Tenerife 38206, Spain.
| | - Jorge Pasán
- Laboratorio de Rayos X y Materiales Moleculares (MATMOL), Departamento de Física, Universidad de La Laguna (ULL), La Laguna, Tenerife 38206, Spain.
| | - Catalina Ruiz-Pérez
- Laboratorio de Rayos X y Materiales Moleculares (MATMOL), Departamento de Física, Universidad de La Laguna (ULL), La Laguna, Tenerife 38206, Spain.
| | - Juan H Ayala
- Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), La Laguna, Tenerife 38206, Spain.
| | - Ana M Afonso
- Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), La Laguna, Tenerife 38206, Spain.
| | - Verónica Pino
- Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), La Laguna, Tenerife 38206, Spain.
- University Institute of Tropical Diseases and Public Health, Universidad de La Laguna (ULL), La Laguna, Tenerife 38206, Spain.
| |
Collapse
|
49
|
Study on four metal organic frameworks as cleanup adsorbents for polycyclic aromatic hydrocarbons determined by GC-MS/MS. Mikrochim Acta 2019; 186:154. [DOI: 10.1007/s00604-019-3271-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 01/20/2019] [Indexed: 01/22/2023]
|
50
|
Applications of Metal-Organic Frameworks in Food Sample Preparation. Molecules 2018; 23:molecules23112896. [PMID: 30404197 PMCID: PMC6278442 DOI: 10.3390/molecules23112896] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2018] [Revised: 11/01/2018] [Accepted: 11/05/2018] [Indexed: 01/22/2023] Open
Abstract
Food samples such as milk, beverages, meat and chicken products, fish, etc. are complex and demanding matrices. Various novel materials such as molecular imprinted polymers (MIPs), carbon-based nanomaterials carbon nanotubes, graphene oxide and metal-organic frameworks (MOFs) have been recently introduced in sample preparation to improve clean up as well as to achieve better recoveries, all complying with green analytical chemistry demands. Metal-organic frameworks are hybrid organic inorganic materials, which have been used for gas storage, separation, catalysis and drug delivery. The last few years MOFs have been used for sample preparation of pharmaceutical, environmental samples and food matrices. Due to their high surface area MOFs can be used as adsorbents for the development of sample preparation techniques of food matrices prior to their analysis with chromatographic and spectrometric techniques with great performance characteristics.
Collapse
|