1
|
Bennett GW, Jarecke L, Wordekemper L, Sundine M. Analysis of occlusal clearance of crown preparations in a predoctoral clinical setting. J Dent Educ 2025; 89:370-374. [PMID: 39390693 PMCID: PMC11903929 DOI: 10.1002/jdd.13737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Revised: 08/28/2024] [Accepted: 09/20/2024] [Indexed: 10/12/2024]
Abstract
PURPOSE This study sought to assess the presence and location of inadequate tooth preparation performed by predoctoral dental students by scanning mounted casts submitted for monolithic zirconia crown fabrication METHODS: An intraoral scanner capable of volumetric measurements of crown preparations was used to analyze 56 crown preparations on mounted stone casts before submission to a lab for crown fabrication. The mounted casts were scanned individually and then a buccal bite was scanned to stitch the models together into virtual occlusion. The distance between the crown preparations and opposing dentition was displayed volumetrically, and the minimum clearance of each preparation was recorded for both the functional and non-functional cusps. Preparations were evaluated for adequate interocclusal clearance and comparisons were made using a Chi-square test with α = 0.05 with respect to tooth location, functional versus nonfunctional cusp, and or single versus multi-unit preparation. RESULTS Over 47% of mounted casts with crown preparations analyzed for the study exhibited a lack of occlusal clearance in at least one area. Functional cusps were more often under-reduced than non-functional (p < 0.001). No other comparisons were statistically significant. CONCLUSIONS The present study demonstrates a high percentage of under-reduced crown preparations in a predoctoral clinic and emphasizes the utility of quality control and analysis via digital scanning of crown preparations prior to crown fabrication.
Collapse
Affiliation(s)
- Gregory W. Bennett
- Department of Adult Restorative DentistryUniversity of Nebraska Medical Center College of DentistryLincolnNebraskaUSA
| | - Lucas Jarecke
- University of Nebraska Medical Center College of DentistryLincolnNebraskaUSA
| | - Luke Wordekemper
- University of Nebraska Medical Center College of DentistryLincolnNebraskaUSA
| | - Makena Sundine
- Department of Adult Restorative DentistryUniversity of Nebraska Medical Center College of DentistryLincolnNebraskaUSA
| |
Collapse
|
2
|
Packaeser MG, Machry RV, Grassi EDA, Saavedra GDSFA, Kleverlaan CJ, Valandro LF, Tribst JPM, Pereira GKR. Influence of core material and occlusal contact pattern on fatigue behavior of different monolithic ceramic crowns. J Mech Behav Biomed Mater 2025; 163:106891. [PMID: 39827822 DOI: 10.1016/j.jmbbm.2025.106891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2024] [Revised: 12/10/2024] [Accepted: 01/08/2025] [Indexed: 01/22/2025]
Abstract
This study evaluated the effect of substrate core materials and occlusal contact patterns on the fatigue mechanical behavior and stress distribution of single-unit ceramic crowns. One hundred and twenty monolithic crowns were fabricated from zirconia (YZ - IPS e.max ZirCAD, Ivoclar), lithium disilicate (LD - IPS e.max CAD, Ivoclar) and polymer infiltrated ceramic network (PICN - Enamic, Vita Zahnfabrik). The crowns were allocated considering two factors: 'substrate' (epoxy resin or cast Ni-Cr metal core) and 'occlusal contact pattern' (contact at the cusp ridges or cusp tips). The substrate models were design, milled and scanned to plan the restorations in a digital workflow. The crowns were milled, bonded to the substrates, and subjected to an accelerated fatigue test (100 N; 10,000 cycles/step; 20 Hz step-size: 100 N up to 1600 N, and after, 200 N until failure or survival at 2,800N; immersed in water). Statistical analyses were performed using two-way ANOVA, Tukey's post-hoc test, and Kaplan-Meier survival analysis (α = 0.05) considering fatigue failure load and cycles for fatigue failure (FFL/CFF). Fractographic and finite element analysis (FEA) were carried out. The results indicate that the 'substrate' factor did not influence the mechanical behavior of YZ and LD monolithic crowns (p > 0.05). However, PICN crowns bonded to epoxy resin exhibited statistically superior results for FFL and CFF (p < 0.05) compared to Ni-Cr cores. Regarding the 'occlusal contact pattern' factor, YZ and LD exhibited higher mean FFL and CFF when associated with cusp tip contact compared to cusp ridge contact (p < 0.05), except for YZ bonded to the epoxy resin substrate (p > 0.05). No differences were detected for the 'occlusal contact' factor in PICN crowns (p > 0.05). The predominant failure was Hertzian cone cracks, regardless of the restorative material. Stress measurements showed higher stress peaks at the cusp ridges. The core material did not alter the fatigue mechanical behavior of YZ or LD crowns. However, the incidence of cusp ridge contacts in YZ or LD crown increases the risk of failure. Conversely, when using PICN crowns, a core with a more similar elastic modulus enhances mechanical behavior compared to a stiffer core, and no influence on the occlusal pattern was observed.
Collapse
Affiliation(s)
- Maria Gabriela Packaeser
- Post-Graduate Program in Oral Sciences (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil.
| | - Renan Vaz Machry
- Post-Graduate Program in Oral Sciences (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil; Department of Restorative Dentistry, Faculty of Dentistry, Federal University of Minas Gerais (UFMG), Belo Horizonte, Minas Gerais, Brazil.
| | - Elisa Donaria Aboucauch Grassi
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, São Paulo, Brazil.
| | | | - Cornelis Johannes Kleverlaan
- Department of Dental Materials, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, the Netherlands.
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil.
| | - João Paulo Mendes Tribst
- Department of Reconstructive Oral Care, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, the Netherlands.
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil.
| |
Collapse
|
3
|
Işisağ Ö, Pektaş N. Comparison of the fracture strengths of single-unit metal-ceramic and monolithic zirconium restorations in the molar region: a systematic review and meta-analysis. Odontology 2024; 112:751-760. [PMID: 38103151 DOI: 10.1007/s10266-023-00878-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Accepted: 11/17/2023] [Indexed: 12/17/2023]
Abstract
Despite the success of monolithic zirconia restorations (MZ), metal-ceramic restorations (MC) are still considered the gold standard for fixed prosthetics in the posterior region. This systematic review and meta-analysis aimed to compare the fracture strengths of single-unit MC and MZ in the molar region. This review was based on the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA, 2020) statement. All articles were searched from the PubMed and Web of Science databases until November 18, 2022. All in vitro studies evaluating the fracture strengths of MC and MZ were also included. Statistical analysis was performed with the Comprehensive Meta-Analysis program, with a significance level of 0.05. Out of 753 studies, five were selected. The fracture strengths of MZ and MC did not show any statistically significant difference for both tooth (95% CI - 1.589: 2.118, p = 0.779, z = 0.280) and implant (95% CI - 2.215: 2.191, p = 0.992 z = - 0.010) supported restorations. However, different abutment materials (p < 0.001) and aging treatments (p < 0.001) in tooth-supported restorations displayed a significant statistical difference. Additionally, a significant difference was also observed in subgroup analysis considering different cements (p = 0.001) and load speeds (p = 0.001) in implant-supported restorations. Fracture strengths of MZ and MC did not show a significant statistical difference in implant or tooth-supported single-unit posterior restorations. MZ may be a suitable alternative to MC in single-unit posterior restorations. The results should be interpreted with caution, as the included studies were in vitro.
Collapse
Affiliation(s)
- Özer Işisağ
- Department of Prosthodontics, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Inonu Boulevard No: 4, Afyonkarahisar, Turkey.
| | - Nur Pektaş
- Department of Prosthodontics, Faculty of Dentistry, Afyonkarahisar Health Sciences University, Inonu Boulevard No: 4, Afyonkarahisar, Turkey
| |
Collapse
|
4
|
Rodrigues JVM, Demachkia AM, da Silva de Assis RAS, Gomes MM, Campos TMB, Dapieve KS, Valandro LF, de Melo RM. Fatigue and failure mode analyses of glass infiltrated 5Y-PSZ bonded onto dentin analogues. Sci Rep 2024; 14:13262. [PMID: 38858417 PMCID: PMC11164944 DOI: 10.1038/s41598-024-64110-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Accepted: 06/05/2024] [Indexed: 06/12/2024] Open
Abstract
The purpose of this study was to evaluate the fatigue survival of 5Y-PSZ zirconia infiltrated with an experimental glass and bonded onto dentin analogues. Disc-shaped specimens of a 5Y-PSZ (Katana UTML Kuraray Noritake) were cemented onto dentin analogs (NEMA G10) and divided into four groups (n = 15): Zctrl Group (control, without infiltration); Zglz Group (Glaze, compression surface); Zinf-comp Group (Experimental Glass, compression surface); Zinf-tens Group (Experimental Glass, tension surface). Surface treatments were varied. Cyclic fatigue loading, oblique transillumination, stereomicroscope examination, and scanning electron microscopy were performed. Fatigue data were analyzed (failure load and number of cycles) using survival analysis (Kaplan-Meier and Log-Rank Mantel-Cox). There was no statistically significant difference in fatigue survival between the Zglz, Zctrl, and Zinf-comp groups. The Zinf-tens group presented a significantly higher failure load when compared to the other groups and exhibited a different failure mode. The experimental glass effectively infiltrated the zirconia, enhancing structural reliability, altering the failure mode, and improving load-bearing capacity over more cycles, particularly in the group where the glass was infiltrated into the tensile surface of the zirconia. Glass infiltration into 5Y-PSZ zirconia significantly enhanced structural reliability and the ability to withstand loads over an increased number of cycles. This approach has the potential to increase the durability of zirconia restorations, reducing the need for replacements and save time and resources, promoting efficiency in clinical practice.
Collapse
Affiliation(s)
- Jonas Vinicius Meireles Rodrigues
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), Av. Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, 12245-000, Brazil
| | - Amir Mohidin Demachkia
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), Av. Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, 12245-000, Brazil
| | - Rita Adriana Souza da Silva de Assis
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), Av. Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, 12245-000, Brazil.
| | - Mariana Marques Gomes
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), Av. Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, 12245-000, Brazil
| | - Tiago Moreira Bastos Campos
- Aeronautics Technological Institute (ITA), Praça Marechal Eduardo Gomes, 50, Vila das Acácias, São José dos Campos, São Paulo, 12228-900, Brazil
| | - Kiara Serafini Dapieve
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Av. Roraima, 1000, Cidade Universitária, Camobi, Santa Maria, Rio Grande do Sul, 97105-900, Brazil
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Science, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Av. Roraima, 1000, Cidade Universitária, Camobi, Santa Maria, Rio Grande do Sul, 97105-900, Brazil
| | - Renata Marques de Melo
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), Av. Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, 12245-000, Brazil
| |
Collapse
|
5
|
Manziuc M, Kui A, Chisnoiu A, Labuneț A, Negucioiu M, Ispas A, Buduru S. Zirconia-Reinforced Lithium Silicate Ceramic in Digital Dentistry: A Comprehensive Literature Review of Our Current Understanding. MEDICINA (KAUNAS, LITHUANIA) 2023; 59:2135. [PMID: 38138238 PMCID: PMC10744576 DOI: 10.3390/medicina59122135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Revised: 11/26/2023] [Accepted: 12/04/2023] [Indexed: 12/24/2023]
Abstract
Zirconia-reinforced lithium silicate (ZLS) ceramic is a new innovative dental material with unique a chemical composition that is designed to combine harmoniously with the appropriate optical properties of lithium disilicate and the enhanced mechanical strength of zirconia. A thorough understanding of ZLS materials is essential for both clinicians and dental technicians. At present, the mechanical behavior and optical properties of the ZLS ceramic system have not been extensively researched, and there is still a lack of consensus regarding the fabrication process and clinical behavior of ZLS all-ceramic restorations. The aim of the present study was to present a selection of comprehensive information concerning zirconia-reinforced lithium silicate ceramics and their optical and mechanical properties, as well as to assess data regarding cementation procedures and clinical outcomes for ZLS all-ceramic restorations. Three electronic databases (PubMed, Web of Science, and the Cochrane Library) were used for the research by two independent reviewers. The search was limited to articles published in the English language, as well as clinical and in vitro studies of color and studies on mechanical behavior and the cementation procedures of ZLS restorations. The exclusion criteria comprised abstracts, questionnaire-based studies, case reports, literature reviews, and studies that were not available in English. Zirconia-reinforced lithium-silicate-based ceramic presents a unique and complex microstructure that increases mechanical resistance but decreases aesthetic appearance, especially its translucency, due to tetragonal zirconia content. A material's thickness, the color of the underlying tooth structure, and the resin cement shade are important factors that influence the final shade and aesthetic appearance of ZLS restorations. Mechanical properties, which are defined by the fracture toughness, flexural strength, elastic modulus, and hardness of ZLS ceramic are higher compared to feldspathic, lithium disilicate, and hybrid ceramics, as well as resin nanoceramics; however, they are lower than translucent or high-translucency zirconia. Acid etching, sandblasting, and laser etching represent the most used methods to prepare the ZLS restoration surfaces for proper bonding procedures.
Collapse
Affiliation(s)
| | - Andreea Kui
- Prosthetic Dentistry and Dental Materials Department, Iuliu Hatieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania; (M.M.); (S.B.)
| | | | | | | | | | | |
Collapse
|
6
|
Ning K, Yang F, Bronkhorst E, Ruben J, Nogueira L, Haugen H, Loomans B, Leeuwenburgh S. Fatigue behaviour of a self-healing dental composite. Dent Mater 2023; 39:913-921. [PMID: 37643923 DOI: 10.1016/j.dental.2023.08.172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 08/10/2023] [Accepted: 08/16/2023] [Indexed: 08/31/2023]
Abstract
OBJECTIVE Novel self-healing resin-based composites containing microcapsules have been developed to improve the mechanical performance of dental restorations. However, the long-term fatigue behaviour of these self-healing composites has still been hardly investigated. Therefore, this manuscript studied the fatigue behaviour of self-healing composites containing microcapsules by subjecting the specimens to traditional staircase tests and ageing in a custom-designed chewing simulator (Rub&Roll) to simulate oral ageing physiologically relevant conditions. METHODS To prepare self-healing composite, poly(urea-formaldehyde) microcapsules containing acrylic self-healing liquids were synthesized. Subsequently, these microcapsules (10 wt%) and initiator (benzoyl peroxide, BPO, 2 wt%) were incorporated into a commercial flowable resin-based composite. Microcapsule-free resin-based composites with and without BPO were also prepared as control specimens. A three-point flexural test was used to measure the initial flexural strength (Sinitial). Subsequently, half of the specimens were used for fatigue testing using a common staircase approach to measure the fatigue strengths (FS). In addition, the other specimens were aged in the Rub&Roll machine for four weeks where after the final flexural strength (Sfinal) was measured. RESULTS Compared to Sinitial, FS of all tested specimens significantly decreased as measured through staircase testing. After 4 weeks of ageing in the Rub&Roll machine, Sfinal was significantly reduced compared to Sinitial for microcapsule-free resin-based composites, but not for the self-healing composites (p = 0.3658). However, the self-healing composites are still in the experimental phase characterized by a low mechanical strength, which still impedes further clinical translation. SIGNIFICANCE Self-healing composites containing microcapsules exhibit improved fatigue resistance compared to microcapsule-free non-self-healing composites.
Collapse
Affiliation(s)
- Ke Ning
- Radboud University Medical Center, Radboud Institute for Molecular Life Sciences, Department of Dentistry, Regenerative Biomaterials, Philips van Leydenlaan 25, Nijmegen, the Netherlands
| | - Fang Yang
- Radboud University Medical Center, Radboud Institute for Molecular Life Sciences, Department of Dentistry, Regenerative Biomaterials, Philips van Leydenlaan 25, Nijmegen, the Netherlands
| | - Ewald Bronkhorst
- Radboud University Medical Center, Radboud Institute for Health Sciences, Department of Dentistry, Restorative Dentistry, Philips van Leydenlaan 25, Nijmegen, the Netherlands
| | - Jan Ruben
- Radboud University Medical Center, Radboud Institute for Health Sciences, Department of Dentistry, Restorative Dentistry, Philips van Leydenlaan 25, Nijmegen, the Netherlands
| | - Liebert Nogueira
- University of Oslo, Institute of Clinical Dentistry, Department of Biomaterials, Oslo 0317, Norway
| | - Håvard Haugen
- University of Oslo, Institute of Clinical Dentistry, Department of Biomaterials, Oslo 0317, Norway
| | - Bas Loomans
- Radboud University Medical Center, Radboud Institute for Health Sciences, Department of Dentistry, Restorative Dentistry, Philips van Leydenlaan 25, Nijmegen, the Netherlands
| | - Sander Leeuwenburgh
- Radboud University Medical Center, Radboud Institute for Molecular Life Sciences, Department of Dentistry, Regenerative Biomaterials, Philips van Leydenlaan 25, Nijmegen, the Netherlands.
| |
Collapse
|
7
|
Zahran M, Abo El-Farag S, Soltan H, Attia A. Fracture load of ultrathin occlusal veneers: Effect of thickness and surface conditioning. J Mech Behav Biomed Mater 2023; 145:106030. [PMID: 37473575 DOI: 10.1016/j.jmbbm.2023.106030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2023] [Revised: 07/12/2023] [Accepted: 07/15/2023] [Indexed: 07/22/2023]
Abstract
OBJECTIVE This in-vitro study is planned to analyze the effect of different thicknesses of ceramic occlusal veneers and different surface treatments on fracture resistance. MATERIALS AND METHODS A total of 48 sound mandibular molars are anatomically prepared from the occlusal surface with two different thicknesses (1.0 and 0.5 mm). CAD/CAM zirconia-reinforced glass ceramic blocks (Vita Suprinity) are used for fabricating occlusal veneers. The teeth are randomly divided into two primary groups A and B (n=24) according to occlusal veneer thickness. Each group is subdivided according to surface conditioning into three equal subgroups (n=8)-subgroup HF: etching with hydrofluoric acid and ceramic primer application; subgroup APF: etching with acidulated phosphate fluoride and ceramic primer application; subgroup EP: conditioning with etch and prime only. Dual-cure adhesive resin cement (Multilink Automix) is utilized to adhesively bond the veneers. All specimens are subjected to 240,000 cycles of dynamic load aging prior to the fracture resistance test. The fracture resistance is measured in Newton (N). The Failure mode patterns are analyzed and categorized using a scanning electron microscope (SEM). The results are analyzed using a two-way ANOVA with Bonferroni's Post-Hoc test, followed by a one-way ANOVA for each factor. That is in addition to one-way ANOVA for surface treatment under each thickness, each followed by Bonferroni's Post-Hoc test. Then, a T-test is used to compare the two thicknesses under each surface treatment. All tests are set at 0.05 significance level. RESULTS The two-way ANOVA test revealed that restoration thickness and surface treatment both significantly affect the fracture resistance values (p<0.05). The highest fracture resistance mean (2672±216N) is obtained from HF at 1.0 mm thickness, while the lowest mean (2104±299N) is obtained from APF at 0.5 mm thickness. CONCLUSION All test groups, regardless of thickness, demonstrated fracture resistance values that exceeded both normal and parafunctional bite forces. The veneers that bonded after hydrofluoric acid etching followed by ceramic primer application showed more favourable fracture patterns.
Collapse
Affiliation(s)
- Maged Zahran
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt.
| | - Shaimaa Abo El-Farag
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt.
| | - Hassan Soltan
- Production and Mechanical Design Engineering Department, Faculty of Engineering, Mansoura University, Mansoura 35516, Egypt.
| | - Ahmed Attia
- Department of Fixed Prosthodontics, Faculty of Dentistry, Mansoura University, Mansoura 35516, Egypt.
| |
Collapse
|
8
|
A brief review on fatigue test of ceramic and some related matters in Dentistry. J Mech Behav Biomed Mater 2023; 138:105607. [PMID: 36549251 DOI: 10.1016/j.jmbbm.2022.105607] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 11/28/2022] [Accepted: 12/05/2022] [Indexed: 12/12/2022]
Abstract
The characteristics of dental ceramics have been extensively studied over the years to provide highly qualified materials for use in prosthetic restorations. The ability to adhere to dental substrates, outstanding aesthetics (translucency, color, and substrate masking ability) and improved mechanical properties provide these materials with optical features and high strength to withstand masticatory stimuli. Different classifications are adopted, and it is generally considered that glass-ceramics have better optical characteristics due to the high glass content, and polycrystalline ceramics have superior strength favored by their densified and organized crystals, hampering crack growth. This knowledge was largely built-up during years of scientific research through different testing methodologies, but mainly employing static loads. It is important to not only take into account the intensity of loads that these materials will be exposed to, but also the effect of the intermittence of cyclic load application leading to mechanical fatigue and the influence of factors related to the crack origin and their propagation under this condition. Furthermore, the bonding surface of ceramic restorations requires surface treatments that improve the bond strength to luting agents; however, these treatments require caution because of their potential to produce defects and affect the structural behavior. Moreover, ceramic restorations often require internal adjustments for proper seating or external adjustments for fitting the occlusal contact with the antagonist. In this sense, finishing/polishing protocols may alter the defect population, as luting agents may also interact by filling in the superficial defects on the restoration intaglio surface. Thus, the balance among all these factors will define the performance of a restorative setup, as well as the posterior exposure to the humid environment and the masticatory stimuli (cyclical loading), which may favor developing slow and subcritical growth of cracks in ceramic materials and the degradation of the bond interface. Therefore, it is essential that the concepts which explain the fatigue mechanism are understood, as well as the crack propagation and failure patterns of restorative ceramic materials.
Collapse
|
9
|
Noronha MDS, Carvalho MAD, Do AQ, Neto VGDA, Campos CH, Giannini M, Magne P. Effect of thickness and CAD-CAM material on fatigue resistance of endodontically treated molars restored with occlusal veneers. J Prosthodont 2023; 32:e19-e29. [PMID: 36087111 DOI: 10.1111/jopr.13606] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 09/06/2022] [Indexed: 11/30/2022] Open
Abstract
PURPOSE To evaluate the influence of the thickness and type of computer-aided design and computer-aided manufacturing (CAD-CAM) material on the fatigue resistance and failure mode of endodontically treated teeth (ETT) restored with occlusal veneers (OV). MATERIALS AND METHODS Seventy-five (N = 75) ETT were restored with Herculite XRV in the endodontic access. Five experimental groups (n = 15) were tested. Four groups had two different thicknesses (0.6-0.7 mm or 1.4-1.6 mm) and two different CAD-CAM materials: zirconia-reinforced lithium-silicate (LS/Celtra Duo) and composite resin (RC/Cerasmart). The fifth group (control) did not have occlusal veneers. All the specimens were subjected to accelerated fatigue (5 Hz frequency) with an occlusal load increasing up to 1800 N and 131,000 cycles. The number of cycles was recorded when the machine stopped or at the completion of the test. Fatigue resistance was analyzed using the Kaplan-Meier survival test (95% significance level, log-rank post hoc pairwise comparisons). The samples were categorized according to failure mode. The CAD-CAM materials were examined through scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). RESULTS No differences were found between the thicknesses, regardless of the type of the CAD-CAM material. The thick LS OV outperformed the RC and control groups. The thin RC OV and control groups showed a higher percentage of repairable and possibly repairable failures than the other groups. LS was more homogeneous under SEM, and the EDS analysis detected Si and Zr, but not Li. CONCLUSIONS A larger thickness did not improve the resistance of the CAD-CAM materials. Thick LS showed a higher cumulative survival rate to fatigue than the RC and control groups. The direct composite alone (control) survived similarly to the experimental groups, except for the thick LS.
Collapse
Affiliation(s)
- Mayara Dos Santos Noronha
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, São Paulo, Brazil
| | | | - Anh Quynh Do
- Advanced Endodontics, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, CA
| | | | - Camila Heitor Campos
- Department of Oral Rehabilitation, School of Dentistry, Federal Fluminense University, Nova Friburgo, Brazil
| | - Marcelo Giannini
- Department of Restorative Dentistry, Piracicaba Dental School, University of Campinas, São Paulo, Brazil
| | - Pascal Magne
- Division of Restorative Sciences, Herman Ostrow School of Dentistry, University of Southern California, Los Angeles, CA
| |
Collapse
|
10
|
Luo B, Sun X, He L, Zhao L, Liu X, Jiang Q. Impact of different axial wall designs on the fracture strength and stress distribution of ceramic restorations in mandibular first molar. BMC Oral Health 2022; 22:549. [PMID: 36456942 PMCID: PMC9714140 DOI: 10.1186/s12903-022-02577-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Accepted: 11/08/2022] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND The purpose of this study was to investigate the fracture strength and stress distribution of four ceramic restorations. METHODS Forty human mandibular first molars were collected and randomized into four groups after establishing the distal defect: full crown group with 4 mm axial wall height (AWH) (FC4); short AWH crown group with 2 mm AWH (SC2); occlusal veneer group with 0 mm AWH (OV0); occlusal distal veneer group with only the distal surface prepared, and 4 mm AWH (OD4). The teeth were prepared according to the groups and the ceramic restorations were completed using celtra duo ceramic blocks. The ceramic thickness of the occlusal surface is about 1.5 mm and the edge is about 1 mm. The failure load values and fracture modes of each group were detected by mechanical test in vitro. According to the groups to establish three-dimensional finite element analysis (FEA) models, a 600 N loading force was applied vertically using a hemispherical indenter with a diameter of 6 mm. and compare the stress distribution under the condition of different restorations. RESULTS In vitro mechanical tests showed that the failure load values were SC2 (3232.80 ± 708.12 N) > OD4 (2886.90 ± 338.72 N) > VO0 (2133.20 ± 376.15 N) > FC4(1635.40 ± 413.05 N). The failure load values of the short AWH crown and occlusal distal veneer were significantly higher than that of occlusal veneer and full crown (P<0.05). The fracture modes of the full crown and occlusal veneer groups were mainly ceramic fractures and some were restorable tooth fractures. The short AWH crown and occlusal distal veneer groups presented with three fracture modes, the proportion of non-restorable tooth fracture was higher. The results of FEA show that under the spherical loading condition, the stress of ceramic was concentrated in the contact area of the loading head, the maximum von Mises stress values were FC4 (356.2 MPa) > VO0 (214.3 MPa) > OD4 (197.9 MPa) > SC2 (163.1 MPa). The stress of enamel was concentrated in the area where the remaining enamel was thinner, the maximum von Mises stress values was OD4 (246.2 MPa) ≈ FC4 (212.4 MPa) > VO0 (61.8 MPa) ≈ SC2 (45.81 MPa). The stress of dentin is concentrated in the root furcation and the upper third region of the root. However, stress concentration was observed at the tooth cervix in the full crown. CONCLUSION Under certain conditions, the occlusal distal veneer shows better performance than the full crown.
Collapse
Affiliation(s)
- Bin Luo
- grid.24696.3f0000 0004 0369 153XDepartment of Prosthodontics, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, 100050 Beijing, China
| | - Xiaolu Sun
- grid.479671.a0000 0004 9154 7430Shunyi Hospital, Beijing Traditional Chinese Medicine Hospital, 100010 Beijing, China
| | - Lin He
- grid.24696.3f0000 0004 0369 153XDepartment of Prosthodontics, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, 100050 Beijing, China
| | - Lidan Zhao
- grid.410737.60000 0000 8653 1072Department of Prosthodontics, Affiliated Stomatology Hospital of Guangzhou Medical University, 510013 Guangzhou, China
| | - Xinggang Liu
- grid.24696.3f0000 0004 0369 153XDepartment of Prosthodontics, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, 100050 Beijing, China
| | - Qingsong Jiang
- grid.24696.3f0000 0004 0369 153XDepartment of Prosthodontics, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, 100050 Beijing, China
| |
Collapse
|
11
|
Guilardi LF, Pereira G, Giordani JC, Kleverlaan CJ, Valandro LF, Rippe MP. Cement Choice and the Fatigue Performance of Monolithic Zirconia Restorations. Oper Dent 2022; 47:461-472. [PMID: 35917240 DOI: 10.2341/20-143-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/21/2021] [Indexed: 11/23/2022]
Abstract
This study investigated the fatigue failure load of simplified monolithic yttria partially stabilized zirconia polycrystal restorations cemented to a dentin-like substrate using different luting systems. Disc-shaped ceramic (Zenostar T, 10 mm Ø × 0.7 mm thick) and dentin-like substrate (10 mm Ø × 2.8 mm thick) were produced and randomly allocated into eight groups, without or with thermocycling (TC=5-55°C/12,000×): "cement" (RelyX Luting 2 - glass ionomer cement [Ion], [Ion/TC]; RelyX U200 - self-adhesive resin cement [Self], [Self/TC]; Single Bond Universal+RelyX Ultimate - MDP-containing adhesive + resin cement [MDPAD + RC], [MDP-AD + RC/TC]; ED Primer II+Panavia F 2.0 - Primer + MDP-containing resin cement [PR + MDP-RC], [PR + MDP-RC/TC])). Each luting system was used as recommended by the manufacturer. Staircase methodology (20 Hz; 250,000 cycles) was applied for obtaining the fatigue failure loads. Fractographic characteristics were also assessed. At baseline, the Ion group presented the lowest fatigue load, although it was statistically similar to the Self group. The resin-based cement systems presented the highest fatigue performance, with the Ion group being only statistically equal to the Self group. Thermocycling influenced the groups differently. After aging, the MDP-AD + RC presented the highest mean, followed by the PR + MDP-RC and Self groups, while the Ion group had the lowest mean. Fractographic analysis depicted all failures as radial cracks starting at the zirconia intaglio surface. The luting system with MDP-containing adhesive applied prior to the resin cement presented the highest fatigue failure load after aging, presenting the best predictability of stable performance. Despite this, monolithic zirconia presents high load-bearing capability regardless of the luting agent.
Collapse
Affiliation(s)
- L F Guilardi
- Luis Felipe Guilardi, associate researcher, Post-Graduate Program in Oral Science (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - Gkr Pereira
- Gabriel Kalil Rocha Pereira, MsciD, PhD, adjunct professor, Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - J C Giordani
- João Carlos Giordani, undergraduate student, Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - C J Kleverlaan
- Cornelis Johannes Kleverlaan, PhD, full professor, Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam, Universiteit van Amsterdam and Vrije Universiteit, Amsterdam, Noord-Holland, The Netherlands
| | - L F Valandro
- Luiz Felipe Valandro, MSciD, PhD, full professor, Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - M P Rippe
- *Marilia Pivetta Rippe, MSciD, PhD, adjunct professor, Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| |
Collapse
|
12
|
Vasiliu RD, Uțu ID, Rusu L, Boloș A, Porojan L. Fractographic and Microhardness Evaluation of All-Ceramic Hot-Pressed and CAD/CAM Restorations after Hydrothermal Aging. MATERIALS (BASEL, SWITZERLAND) 2022; 15:3987. [PMID: 35683294 PMCID: PMC9182156 DOI: 10.3390/ma15113987] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/30/2022] [Revised: 05/29/2022] [Accepted: 06/02/2022] [Indexed: 12/04/2022]
Abstract
All-ceramic dental restorations have great advantages, such as highly esthetical properties, a less complex fabrication, and a similar abrasion resistance to enamel. Despite these advantages, ceramic materials are more prone to fracture due to their brittle microstructure. The main aim of this in vitro study was to determine the difference in hot-pressed and milled glass-ceramic mechanical properties such as fracture resistance and microhardness (VHN). Four types of ceramics, two hot-pressed and two milled, feldspathic glass-ceramics and zirconia-reinforced glass-ceramics were selected in this study and tested using the static loading test and Vicker’s testing. Hydrothermal aging, consisting of different baths with temperatures between 5 degrees Celsius and 55 degrees Celsius, was chosen as the in vitro aging method. Statistical analyses are performed using SPSS Statistics software at a significance level of p < 0.05. Micro-hardness values decrease after hydrothermal aging. The static loading test reveals a significant difference between the feldspathic hot-pressed glass-ceramic, which fractures at lower forces, and milled zirconia-reinforced lithium silicate glass-ceramic, which fractures at greater forces (N). Fractographic analysis of the fractured fragments resulted in the static loading test revealing different surface features about the crack origins and propagations under a stereomicroscope.
Collapse
Affiliation(s)
- Roxana Diana Vasiliu
- Center for Advanced Technologies in Dental Prosthodontics, Department of Dental Prostheses Technology (Dental Technology), Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timișoara, Romania;
| | - Ion-Dragoș Uțu
- Departament of Materials Engineering and Fabrication, University of Politehnică Timişoara, Bd. Mihai Viteazul nr.1, 300222 Timişoara, Romania;
| | - Lucian Rusu
- Department Mechanics and Vibrations, Faculty of Mechanical Engineering, Politehnica University, 1 Mihai Viteazu Street, 300222 Timisoara, Romania;
| | - Adrian Boloș
- Department of Oral Rehabilitation (Dental Technique), Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timișoara, Romania;
| | - Liliana Porojan
- Center for Advanced Technologies in Dental Prosthodontics, Department of Dental Prostheses Technology (Dental Technology), Faculty of Dental Medicine, “Victor Babeș” University of Medicine and Pharmacy Timișoara, Eftimie Murgu Sq. No. 2, 300041 Timișoara, Romania;
| |
Collapse
|
13
|
Martins JD, Moura DMD, Lima CM, de Carvalho RLA, Leite FPP, Souza ROA. Surface Treatment and Cementation of Lithium Silicate Ceramics Containing ZrO2. Oper Dent 2022; 47:202-213. [DOI: 10.2341/20-156-l] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/10/2021] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective
To evaluate the effect of different surface treatments on the shear bond strength (SBS) of lithium silicate (LS) and lithium disilicate (LD) ceramics, after thermocycling.
Methods and Materials
For SBS test, 72 ceramic blocks (18×14×2 mm) were made (24 blocks from each ceramic material): VITA Suprinity (LSS), Celtra Duo (LSC), and Lithium disilicate (LD). The blocks were polished with sandpaper of increasing grit (#280, #400, #800, and #1200) and embedded in chemically activated acrylic resin. Afterwards, they were randomly divided into 12 groups (6 blocks per group) according to: “Ceramic” (LD, LSC, and LSS) and “Surface treatment” (HFS: hydrofluoric acid + silane; MEP: Monobond Etch & Prime/Ivoclar). From each treated surface ceramic block, four dual-curing resin cement cylinders (RelyX U200, 3M Oral Care) were prepared using a Tygon tube (Ø=3 mm and h=2 mm) and light cured for 40 seconds (1000 mW/cm2) (N=288/n=24). All specimens were submitted to thermocycling (10,000 cycles, 5°C and 55°C, 30 seconds) and then to SBS test at a crosshead speed of 1 mm/min using a 50-kgf load cell. Forty-five additional blocks were made for roughness and SEM analysis. Failure mode was also performed. The data (MPa) were statistically analyzed by oneway analysis of variance (ANOVA), Tukey test (5%), and Weibull analysis. The Ra was analyzed by Kruskal–Wallis and Dunn Test (5%). The other variables were analyzed qualitatively.
Results
ANOVA revealed that “surface treatment” was significant for all ceramic materials (p<0.05). The LD-HFS (18.66±3.49), LSC-HFS (16.81±2.62), and LSS-HFS (16.33±3.08) groups had significantly higher SBS than the LD-MEP (7.00±4.2), LSC-MEP (14.12±3.51), and LSS-MEP (13.87±2.52) groups. Complete adhesive failures at the cement– dentin interface were more frequent. Weibull modulus was superior for the LD-HFS (6.22), LSC-HFS (8.8), and LSS-HFS (7.4) groups.
Conclusion
HF followed by silanization is the most suitable surface treatment for the cementation of LS and LD glass ceramics.
Collapse
Affiliation(s)
- JD Martins
- Jordana Dias Martins, DDS, MSc, Department of Restorative Dentistry, School of Dentistry, Federal University of Juiz de Fora (UFJF), São Pedro, Juiz de Fora, Brazil
| | - DMD Moura
- Dayanne Monielle Duarte Moura, DDS, MSc, PhD, professor, Department of Dentistry, State University of Rio Grande do Norte (UERN), Caicó/RN, Brazil
| | - CM Lima
- Camila Moreira Lima, DDS, MSc, PhD student, Department of Restorative Dentistry, School of Dentistry, Federal University of Juiz de Fora (UFJF), São Pedro, Juiz de Fora, Brazil
| | - RLA de Carvalho
- Ronaldo Luís Almeida de Carvalho, MSc, PhD, professor, Department of Dentistry, School of Dentistry, Centro Universitário Braz Cubas, Mogi das Cruzes, Brazil
| | - FPP Leite
- Fabíola Pessôa Pereira Leite, DDS, MSc, PhD, professor Department of Restorative Dentistry, School of Dentistry, Federal University of Juiz de Fora (UFJF), São Pedro, Juiz de Fora, Brazil
| | - ROA Souza
- *Rodrigo Othávio Assunção e Souza, DDS, MSc, PhD, adjunct professor, Health Science Center, Department of Dentistry, School of Dentistry, Federal University of Rio Grande do Norte (UFRN), Lagoa Nova, Natal, Brazil
| |
Collapse
|
14
|
Tanaka IV, Tribst JPM, Silva-Concilio LR, Bottino MA. Effect of Different Ceramic Materials on Fatigue Resistance and Stress Distribution in Upper Canines with Palatal Veneers. Eur J Dent 2022; 16:856-866. [PMID: 35114726 DOI: 10.1055/s-0041-1740225] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
OBJECTIVE The aim of this study was to evaluate, by means of a fatigue life test, different ceramic materials used in palatal veneers to restore the canine guidance. MATERIALS AND METHODS Forty-five standardized anatomical preparations were made in extracted healthy human canines with 1.2 uniform thickness. Samples were scanned, restorations were designed and milled in polymer-infiltrated ceramic network (PICN, Vita Enamic), zirconia-reinforced lithium silicate (ZLS, Vita Suprinity), and high translucent yttrium oxide-stabilized tetragonal zirconia (YZHT, Vita YZHT). Dental preparations were etched, restorations were processed according to the manufacturers' recommendations, and adhesively cemented. Then, three samples of each group were tested with load-to-fracture to determine the fatigue parameters. In addition, the palatal veneers stresses were evaluated using numerical models through finite element analysis. RESULTS The mean of the monotonic test for PICN, ZLS, and YZHT was 674.18 N, 560.5 N, and 918.98 N, respectively. The StepWise test was performed until specimen fracture or until suspension of the test after 1.2 × 106 cycles. Regarding survival, using the Kaplan-Meier method, PICN presented results for the mean and median of 245.21 N and 225 N, respectively; ZLS had an average of 175.76 N and a median of 168 N, and YZHT with an average of 383.30 N and a median of 366 N. Regarding the Weibull method, PICN showed results of 5.43 β and 264 η for form and scale, respectively; ZLS had 36.14 β for form and 380.67 η for scale; and YZHT presented 4.95 β for form and 417.38 η for scale. The highest stress value was calculated for YZHT, ZLS, and PICN, respectively. CONCLUSIONS It was possible to conclude that all tested materials have the possibility of being used for rehabilitation of upper canines' palatal surface.
Collapse
Affiliation(s)
- Isabela Vitelli Tanaka
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University, São José dos Campos, São Paulo, Brazil
| | | | | | - Marco Antonio Bottino
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University, São José dos Campos, São Paulo, Brazil
| |
Collapse
|
15
|
Flexural Strength of Vitreous Ceramics Based on Lithium Disilicate and Lithium Silicate Reinforced with Zirconia for CAD/CAM. Int J Biomater 2022; 2022:5896511. [PMID: 35154328 PMCID: PMC8828337 DOI: 10.1155/2022/5896511] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 12/30/2021] [Accepted: 01/13/2022] [Indexed: 11/27/2022] Open
Abstract
The dental prosthesis market is rapidly evolving to meet patient and clinical demands. These new materials must have good flexural strength, toughness, aesthetic properties, and reliability in performance for structural applications. The present work aimed to compare the bending strength of 4 types of chairside lithium disilicate (Li2Si2O5) glass-ceramics used for dental prosthesis and to analyze the influence of heat treatment on the transformation of lithium metasilicate (Li2SiO3) into lithium disilicate. The three-ball test for the biaxial flexion test (B3B) was used. Weibull statistical analysis was used, and it showed that samples with a higher percentage of zirconia have a greater tendency to fail. The flexion tests showed that the addition of more than 10% of zirconia reduced the flexural strength. The heat treatment process improves and provides greater mechanical strength. The XRD results indicated that the samples with the lowest percentage of zirconia exhibited greater crystallinity and corroborated the microstructural analysis. SEM analyses showed a greater amount and elongated crystals of lithium disilicate when comparing samples with a higher percentage of zirconia. Therefore, samples with lower zirconia showed greater flexural strength than samples with higher additions of zirconia.
Collapse
|
16
|
Cadore-Rodrigues AC, Machry RV, Zucuni CP, Pereira GKR, Valandro LF. Grinding and polishing of the inner surface of monolithic simplified restorations made of zirconia polycrystals and lithium disilicate glass-ceramic: Effects on the load-bearing capacity under fatigue of the bonded restorations. J Mech Behav Biomed Mater 2021; 124:104833. [PMID: 34562764 DOI: 10.1016/j.jmbbm.2021.104833] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 09/01/2021] [Accepted: 09/07/2021] [Indexed: 10/20/2022]
Abstract
This study evaluated the effect of grinding and polishing the inner surface of monolithic discs made of zirconia polycrystals (ZR) and lithium disilicate glass-ceramic (LD) on the load-bearing capacity under fatigue of the restorations bonded onto a dentin analogue material (epoxy resin). ZR and LD ceramic discs (10 mm in diameter, 1 mm in thickness) were produced and randomly allocated into 10 groups considering the internal adjustment approach: Ctrl - No adjustment; F - Grinding with fine diamond bur (46 μm); F + Pol - Grinding with fine diamond bur followed by polishing with 2 tips (finisher and polisher); FF - Grinding with extrafine diamond bur (30 μm); FF + Pol - Grinding with extrafine diamond bur followed by polishing. In addition, discs (10 mm in diameter, 2.5 mm in thickness) of fiber reinforced epoxy resin were produced. Afterwards, the intaglio surface of the ZR discs were air-abraded with 45 μm alumina particles for 10 s, the LD and resin epoxy discs were etched with hydrofluoric acid (5%/20 s and 10%/60 s, respectively), and the treated discs were primed as recommended. Each ceramic disc was luted onto the epoxy resin disc with resin cement. Then, the samples were tested under a step-stress fatigue test (20 Hz, 10,000 cycles/step, step-size of 100 N starting at 200 N, and proceeding until failure detection). Fractographic, topographic and surface roughness analysis were also performed. The adjustments (grinding with or without polishing) (ZR: 733-880 N; LD: 1040-1106 N) triggered a detrimental effect on the fatigue behavior in both ceramics compared with the absence of treatment (control group; ZR: 973 N; LD: 1406 N). The polishing step had no effect on fatigue findings. Thus, grinding the inner surface of the tested ceramics should be avoided wherever possible to prevent introducing damage and its detrimental effects on the fatigue behavior.
Collapse
Affiliation(s)
- Ana Carolina Cadore-Rodrigues
- MSciD and PhD Post-Graduate Program in Oral Sciences (Prosthodontic Units), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Renan Vaz Machry
- MSciD and PhD Post-Graduate Program in Oral Sciences (Prosthodontic Units), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Camila Pauleski Zucuni
- MSciD and PhD Post-Graduate Program in Oral Sciences (Prosthodontic Units), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Gabriel Kalil Rocha Pereira
- MSciD and PhD Post-Graduate Program in Oral Sciences (Prosthodontic Units), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| | - Luiz Felipe Valandro
- MSciD and PhD Post-Graduate Program in Oral Sciences (Prosthodontic Units), Faculty of Odontology, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil.
| |
Collapse
|
17
|
Zhang LX, Hong DW, Zheng M, Yu H. Is the bond strength of zirconia-reinforced lithium silicate lower than that of lithium disilicate? A systematic review and metaanalysis. J Prosthodont Res 2021; 66:530-537. [PMID: 34853237 DOI: 10.2186/jpr.jpr_d_20_00112] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE This study systematically reviewed the literature to compare the bond strength of resin composites with that of zirconia-reinforced lithium silicate (ZLS) and lithium disilicate (LD). STUDY SELECTION This review was structured based on the Preferred Reporting Items for Systematic Reviews and MetaAnalyses (PRISMA 2020) statement. This study was registered at the International Prospective Register of Systematic Reviews (CRD42021256900). Studies were searched via PubMed, Web of Science, and Google Scholar databases without language or publication year limits. In vitro studies that evaluated the bond strength of the resin composites to ZLS and LD were included. The risk of bias in all the included articles was evaluated. Statistical analyses were performed using the Review Manager software (version 5.3, Cochrane Collaboration, Oxford, UK). RESULTS Of the 90 potentially related articles, the full texts of 16 articles were evaluated after screening. Finally, sevenstudies were included in the qualitative synthesis and meta-analysis. All the studies presented a medium risk of bias. The results showed no significant difference in bond strength between the ZLS and LD groups (P = 0.94, mean difference=0.08, and 95% confidence interval=-1.93 to 2.10). However, a significant difference was found in the subgroup analysis considering different types of aging treatments (P = 0.0008) and different types of bond strength tests (P < 0.00001). CONCLUSION The bond strength of resin composites was found to be similar to that of ZLS and LD, but different aging treatments and bond strength tests exhibited varying effects on the bond strength.
Collapse
Affiliation(s)
- Li-Xian Zhang
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
| | - Deng-Wei Hong
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
| | - Ming Zheng
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China
| | - Hao Yu
- Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou, China.,Department of Applied Prosthodontics, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki, Japan
| |
Collapse
|
18
|
Meng Q, Zhang Y, Chi D, Gong Q, Tong Z. Resistance fracture of minimally prepared endocrowns made by three types of restorative materials: a 3D finite element analysis. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2021; 32:137. [PMID: 34716807 PMCID: PMC8557147 DOI: 10.1007/s10856-021-06610-x] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Accepted: 09/28/2021] [Indexed: 06/13/2023]
Abstract
A thin endocrown restoration was often applied in endodontically treated teeth with vertical bite height loss or inadequate clinical crown length. A model of mandibular molars made by endocrown restoration with 1 mm thickness and 2 mm depth of pulp chamber was constructed and imported into FEA ANSYS v18.0 software. The three CAD/CAM materials, feldspathic (Mark2), lithium disilicate (EMAX), and lava ultimate (LU), were assigned, and the five load indenters were loaded on the full occlusal (FO), occlusal center (OC), central fossa (CF), buccal groove (BG), and mesiobuccal cusp (MC) of restoration in the model. The MinPS and MaxPS of the thin endocrown were significantly higher than those of tooth tissue in five types of loads except for the LU endocrown loaded in the FO group. The smaller the contact surface of the load was, the higher MaxPS and MinPS were. MaxPS and MinPS of the MC were the highest, followed by the BG and CF in the restoration. In the stress distribution of tooth tissue, MaxPS in the LU endocrown accumulated at the external edge of enamel and was significantly higher than MaxPS in Mark2 and EMAX endocrown concentrated on the chamber wall of dentin under OC, CF and BG loads. Within the limitations of this FEA study, the LU endocrown transferred more stress to tooth tissue than Mark2 and EMAX, and the maximum principal stress on endocrown restoration and tooth tissue at the mesiobuccal cusp load was higher than that at the central fossa and buccal groove load.
Collapse
Affiliation(s)
- Qingzhen Meng
- Department of Operative Dentistry and Endodontics, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China
- Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China
| | - Yuejiao Zhang
- Department of Operative Dentistry and Endodontics, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China
- Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China
| | - Danlu Chi
- The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, China
| | - Qimei Gong
- Department of Operative Dentistry and Endodontics, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China
- Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China
| | - Zhongchun Tong
- Department of Operative Dentistry and Endodontics, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China.
- Guangdong Provincial Key Laboratory of Stomatology, Sun Yat-sen University, Guangzhou, Guangdong, China.
| |
Collapse
|
19
|
SHAFIGH ELNAZ, ASHRAFI MEHRAN. A REVIEW OF MECHANICAL BEHAVIOR OF DENTAL CERAMIC RESTORATIONS. J MECH MED BIOL 2021. [DOI: 10.1142/s0219519421500639] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Dental ceramics are well known for restoring the function and aesthetic of lost or damaged teeth. Understanding these materials’ mechanical and aesthetic properties can make a suitable choice for those materials. The longevity of dental ceramics depends on several factors, including manufacturing method, clinical process, and the oral cavity’s aqueous environment. Failure mechanisms in restorative ceramics are complex and a combination of several factors. Different microstructures in the crystalline phase will involve the propagation of cracks and eventually the fatigue of ceramic materials. Large grains reduce mechanical performance compared to small grain sizes. Aesthetic materials used for veneering are weaker than the core materials and fail when even subjected to small loads. The soft bonding in the core–veneer interface and possible residual stresses created during the veneering method are drawbacks of these systems. Studies on the mechanical behavior of these materials have grown significantly in recent years and provide helpful information about static and fatigue experimentation and the failure behavior of various materials used in dental crowns.
Collapse
Affiliation(s)
- ELNAZ SHAFIGH
- Operative Dentistry Department, Faculty of Dentistry, AJA University of Medical Sciences, Tehran, Iran
| | - MEHRAN ASHRAFI
- Operative Dentistry Department, Faculty of Dentistry, AJA University of Medical Sciences, Tehran, Iran
| |
Collapse
|
20
|
Dalla-Nora F, Guilardi LF, Zucuni CP, Valandro LF, Rippe MP. Fatigue Behavior of Monolithic Zirconia-Reinforced Lithium Silicate Ceramic Restorations: Effects of Conditionings of the Intaglio Surface and the Resin Cements. Oper Dent 2021; 46:316-326. [PMID: 34251409 DOI: 10.2341/20-025-l] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/12/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVE This study assessed the effect of conditioning of the intaglio surface and resin cements on the fatigue behavior of zirconia-reinforced lithium silicate ceramic (ZLS) restorations cemented to a dentin analogue. METHODS ZLS ceramic (Ø=10 mm, thickness=1.5 mm) and dentin analogue (Ø=10 mm, thickness=2.0 mm) discs were produced and allocated according to the study factors, totaling nine study groups: ceramic surface treatment (three levels: hydrofluoric acid etching [HF]; self-etching ceramic primer [EP]; tribochemical silica coating [TBS]) and resin cement (three levels: 10-methacryloyloxydecyl dihydrogen phosphate [nMDP]; MDP-containing conventional resin cement [MDP]; self-adhesive resin cement [SA]). The ceramic bonding surfaces were treated and cemented on the dentin analogue, and all the specimens were aged for 5000 thermal cycles (5°C-55°C) prior to fatigue testing. The stepwise fatigue test (20 Hz frequency) started with a load of 400 N (5000 cycles) followed by steps of 500, 600, and up to 1800 N (step-size: 100 N) at a maximum of 10,000 cycles each step. The specimens were loaded until failure (crack), which was detected by light transillumination and visual inspection at the end of each step. The fatigue failure load and number of cycles for failure data were analyzed by the Kaplan-Meier (log-rank test; α=0.05). Topographic and fractographic analyses were also performed. RESULTS HF- (973.33-1206.67 N) and EP- (866.67-1066.67 N) treated specimens failed at statistically similar loads and higher than TBS (546.67-733.33 N), regardless of the cement used. All the fractographical inspections demonstrated failure as radial crack. CONCLUSION The HF and EP treatments promoted better mechanical fatigue behavior of the ceramic restoration, while tribochemical silica coating induced worse fatigue results and should be avoided for treating the ZLS surface prior to bonding.
Collapse
|
21
|
Zarone F, Ruggiero G, Leone R, Breschi L, Leuci S, Sorrentino R. Zirconia-reinforced lithium silicate (ZLS) mechanical and biological properties: A literature review. J Dent 2021; 109:103661. [PMID: 33864886 DOI: 10.1016/j.jdent.2021.103661] [Citation(s) in RCA: 45] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Revised: 04/06/2021] [Accepted: 04/08/2021] [Indexed: 01/17/2023] Open
Abstract
OBJECTIVES This paper aimed to provide a literature review of the mechanical and biological properties of zirconia-reinforced lithium silicate glass-ceramics (ZLS) in Computer-aided design / Computer-aided manufacturing (CAD/CAM) systems. DATA/SOURCES An extensive search of the literature for papers related to ZLS was made on the databases of PubMed/Medline, Scopus, Embase, Google Scholar, Dynamed, and Open Grey. The papers were selected by 3 independent calibrated reviewers. STUDY SELECTION The search strategy produced 937 records. After the removal of duplicates and the exclusion of papers that did not meet the inclusion criteria, 71 papers were included. CONCLUSIONS After reviewing the included records, it was found that two types of ZLS (Vita Suprinity PC; Vita Zahnfabrik and Celtra Duo; Dentsply Sirona) are nowadays available on the market for CAD/CAM systems, similar in their chemical composition, microstructure, and biological-mechanical properties. ZLS is reported to be a biocompatible material, whose fracture resistance can withstand physiological chewing loads. The firing process influences the improvements of strength and fatigue failure load, with a volumetric shrinkage. To date, ZLS can be considered a viable alternative to other glass-ceramics for fixed single restorations. CLINICAL SIGNIFICANCE . As to biocompatibility and mechanical properties of ZLS, data are still scarce, often controversial and limited to short-term observational periods. These promising ceramics require further in vitro/in vivo studies to accurately define mechanical and biological properties, mainly in the long-term performance of restorations produced with such materials.
Collapse
Affiliation(s)
- Fernando Zarone
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Prosthodontics and Digital Dentistry, University "Federico II" of Naples, Via Pansini 5, 80131, Naples, Italy.
| | - Gennaro Ruggiero
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Prosthodontics and Digital Dentistry, University "Federico II" of Naples, Via Pansini 5, 80131, Naples, Italy.
| | - Renato Leone
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Prosthodontics and Digital Dentistry, University "Federico II" of Naples, Via Pansini 5, 80131, Naples, Italy.
| | - Lorenzo Breschi
- Department of Biomedical and Neuromotor Sciences, DIBINEM, University of Bologna, Alma Mater Studiorum, Via San Vitale 59, 40125, Bologna, Italy.
| | - Stefania Leuci
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Oral Medicine Unit, School of Medicine, University "Federico II" of Naples, Via Pansini 5, 80131, Naples, Italy.
| | - Roberto Sorrentino
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, Division of Prosthodontics and Digital Dentistry, University "Federico II" of Naples, Via Pansini 5, 80131, Naples, Italy.
| |
Collapse
|
22
|
Rocca GT, Baldrich B, Saratti CM, Delgado LM, Roig M, Daher R, Krejci I. Restoration's thickness and bonding tooth substrate are determining factors in minimally invasive adhesive dentistry. J Prosthodont Res 2021; 65:407-414. [PMID: 33762503 DOI: 10.2186/jpr.jpr_d_20_00008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Purpose To explore fracture strength and failure behaviour of minimally invasive CAD-CAM composite resin overlay restorations.Methods Eighty bi- and tri-layer cylindrical overlay model including the restoration bonded over bovine tooth dentin (Groups D) and enamel-dentin (Groups E) were assembled (diameter 9 mm). Restorations were milled from CAD-CAM composite resin blocks (Brilliant Crios, Coltène/Whaledent AG) in different thicknesses (0.5mm, 1mm, 1.5mm, 2mm) and equally distributed in four Groups D and four Groups E (n=10). All specimens were submitted to an Hertzian load-to-failure contact test with spherical indenter. Critical loads were recorded in Newton and data were analysed using Kruskal-Wallis test for multiple and Mann-Whitney test for 2-samples comparisons (p < 0.05). Fragments were examined using SEM. The stress distribution for specimens with restorations of 0.5 mm and 2 mm was also investigated with FEA.Results For all specimens, the mean static loads in Newton increased with an increase in restoration thickness. On contrary, restorations with the same thickness displayed higher resistance values when bonded over enamel than dentin, except for the 2-mm thick restorations. A damage competition was detected between cone/median cracks originating at the loading contact area of the restorations and radial cracks beginning at their inner surface, with the former prevailing in restorations bonded on enamel and the latter being dominant for restorations bonded on dentin.Conclusions For bonded ultra-thin resin composite restorations (0.5 mm to 1.5 mm) enamel as bonding substrate assures higher critical loads to fracture than dentin. This influence gradually decreases as restoration thickened.
Collapse
Affiliation(s)
- Giovanni Tommaso Rocca
- Division of Cariology and Endodontology, School of Dentistry, University of Geneva, Geneva, Switzerland
| | - Borja Baldrich
- Department of Restorative Dentistry, Universitat Internacional de Catalunya, Barcelona, Spain
| | - Carlo Massimo Saratti
- Division of Cariology and Endodontology, School of Dentistry, University of Geneva, Geneva, Switzerland
| | - Luis Maria Delgado
- Bioengineering Institute of Technology, Universitat Internacional de Catalunya, Barcelona, Spain
| | - Miguel Roig
- Department of Restorative Dentistry, Universitat Internacional de Catalunya, Barcelona, Spain
| | - Rene Daher
- Division of Cariology and Endodontology, School of Dentistry, University of Geneva, Geneva, Switzerland
| | - Ivo Krejci
- Division of Cariology and Endodontology, School of Dentistry, University of Geneva, Geneva, Switzerland
| |
Collapse
|
23
|
Lima CM, Silva NRD, Martins JD, Miranda JS, Tanaka R, Souza RODAE, Leite FPP. Effect of different surface treatments on the biaxial flexure strength, Weibull characteristics, roughness, and surface topography of bonded CAD/CAM silica-based ceramics. Dent Mater 2020; 37:e151-e161. [PMID: 33298316 DOI: 10.1016/j.dental.2020.11.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Revised: 06/28/2020] [Accepted: 11/13/2020] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To investigate the influence of different surface treatments on biaxial flexure strength, roughness, and surface topography of lithium silicate/disilicate-based ceramics. METHODS 225 discs (∅: 12 mm; 1.2 mm - ISO 6872) were made from three ceramics: IPS e.max CAD (LD - Ivoclar Vivadent), Suprinity (LSS - Vita) and Celtra Duo (LSC - Dentsply). The samples were randomly divided into 5 groups (n = 15): no treatment (C); 10% hydrofluoric acid + silane (HF); sandblasting Al2O3 + silane (SB); silicatization + silane (SC); and self-etching ceramic primer (SEP). After surface treatment, a resin cement layer was applied to the disc surface (RelyX U200, 3M ESPE), mechanical cycled (1.2 × 106 cycles, 50 N, 3.8 Hz) and submitted to biaxial flexural strength test (1 mm/min, 1000 Kgf). Roughness, EDS and SEM were also performed. Data were analyzed by one-way ANOVA, Tukey test (5%) and Weibull. RESULTS ANOVA revealed that the "surface treatment" factor was significant for all ceramics (p < 0.05). The groups LD-HF (289.30 ± 40) LD-SEP (298. 87 ± 53.29), LSC-HF (195.51 ± 42.12), LSS-HF (269.58 ± 27.07) and LSS-SEP (207.45 ± 28.63) presented significantly higher biaxial flexure strength than respective control groups, except for the LSC-SEP (165.41 ± 33.86), which was statistically similar to the control. The Weibull modulus was significantly higher for the LD-SB, LSC-SC groups. Additionally, the LD-SB, LSC-SC and LSS-HF groups showed higher roughness compared to the other treatments. SIGNIFICANCE HF etching followed by silanization and self-etching ceramic primer are the most suitable surface treatments for lithium silicate/disilicate-based glass-ceramics.
Collapse
Affiliation(s)
- Camila Moreira Lima
- Federal University of Juiz de Fora (UFJF), Dental School, St. José Lourenço Kelmer, s/n - São Pedro, Juiz de Fora, MG, CEP: 36036-900, Brazil.
| | - Nathalia Ramos da Silva
- Federal University of Rio Grande do Norte (UFRN), Department of Dentistry, Av. Salgado Filho, 1787 - Lagoa Nova, Natal, RN, CEP: 59056-000, Brazil.
| | - Jordana Dias Martins
- Federal University of Juiz de Fora (UFJF), Dental School, St. José Lourenço Kelmer, s/n - São Pedro, Juiz de Fora, MG, CEP: 36036-900, Brazil.
| | - Jean Soares Miranda
- Braz Cubas University, Department of Dentistry, Av. Francisco Rodrigues Filho, 1233 - Vila Mogilar, Mogi das Cruzes, SP, CEP: 08773-380, Brazil.
| | - Ricardo Tanaka
- University of São Paulo (USP), Dental School, St. João de Santa Maria, 129 - Vila Brasilina, São Paulo, SP, CEP: 04158-070, Brazil.
| | - Rodrigo Othávio de Assunção E Souza
- Federal University of Rio Grande do Norte (UFRN), Department of Dentistry, Av. Salgado Filho, 1787 - Lagoa Nova, Natal, RN, CEP: 59056-000, Brazil.
| | - Fabíola Pessôa Pereira Leite
- Federal University of Juiz de Fora (UFJF), Dental School, St. José Lourenço Kelmer, s/n - São Pedro, Juiz de Fora, MG, CEP: 36036-900, Brazil.
| |
Collapse
|
24
|
Ruggiero MM, Soares Gomes R, Pedroso Bergamo ET, Freitas MIM, Bonfante EA, Del Bel Cury AA. Resin-matrix ceramics for occlusal veneers: Effect of thickness on reliability and stress distribution. Dent Mater 2020; 37:e131-e139. [PMID: 33276957 DOI: 10.1016/j.dental.2020.11.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 07/31/2020] [Accepted: 11/02/2020] [Indexed: 11/16/2022]
Abstract
OBJECTIVE To evaluate the influence of resin-matrix ceramic material and thickness on reliability and stress distribution of occlusal veneers (OV). METHODS One hundred and twenty-six OV of a mandibular first molar were milled using a CAD/CAM system and allocated according to materials (resin nanoceramic (RNC) or polymer-infiltrated ceramic network (PICN)) and thicknesses (0.5, 1.0 and 1.5 mm), totaling six groups (RNC0.5, RNC1, RNC1.5, PICN0.5, PICN1, and PICN1.5). Step-stress accelerated-life testing was performed (n = 21/group) with the load applied at the distobuccal cusp tip of the occlusal veneer until failure or suspension. The use level probability Weibull curves and reliability were calculated and plotted (90% CI). Finite element analysis evaluated the stress distribution according to maximum principal stress (σmax) on the restoration and maximum shear stress (τmax) on the cement layer. RESULTS There was no difference in the probability of survival for the estimated missions among the groups, except at 600 N in which the results were significantly lower to PICN1.5 (6%) compared to RNC1 (55%) and RNC1.5 (60%). The σmax values were higher for PICN (31.85-48.63 MPa) than RNC (30.78-33.09 MPa) in the same thicknesses. In addition, 0.5 mm groups concentrated more stress in the restoration (33.09-48.63 MPa) than 1.0 mm (31.11-35.36 MPa) and 1.5 mm (30.78-31.85 MPa) groups in the same material. SIGNIFICANCE Both resin-matrix ceramic materials seem up-and-coming restorative systems for occlusal veneers irrespective of the thicknesses as a consequence of the high reliability.
Collapse
Affiliation(s)
- Mirelle Maria Ruggiero
- Department of Prosthodontics and Periodontology, University of Campinas - Piracicaba Dental School, Limeira Avenue, 901, Piracicaba, SP, 13414-903, Brazil
| | - Rafael Soares Gomes
- Department of Prosthodontics and Periodontology, University of Campinas - Piracicaba Dental School, Limeira Avenue, 901, Piracicaba, SP, 13414-903, Brazil
| | - Edmara Tatiely Pedroso Bergamo
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Dr. Octávio Pinheiro Brisolla Avenue, 9-75, Bauru, SP, 17012-901, Brazil
| | - Mariana Itaborai Moreira Freitas
- Department of Prosthodontics and Periodontology, University of Campinas - Piracicaba Dental School, Limeira Avenue, 901, Piracicaba, SP, 13414-903, Brazil
| | - Estevam Augusto Bonfante
- Department of Prosthodontics and Periodontology, University of São Paulo - Bauru School of Dentistry, Dr. Octávio Pinheiro Brisolla Avenue, 9-75, Bauru, SP, 17012-901, Brazil
| | - Altair Antoninha Del Bel Cury
- Department of Prosthodontics and Periodontology, University of Campinas - Piracicaba Dental School, Limeira Avenue, 901, Piracicaba, SP, 13414-903, Brazil.
| |
Collapse
|
25
|
Machado PS, Pereira GKR, Rodrigues CDS, Guilardi LF, Valandro LF, Rippe MP. Fatigue behavior and colorimetric differences of a porcelain-veneered zirconia: effect of quantity and position of specimens during firing. J Prosthodont Res 2020; 65:202-207. [PMID: 33028795 DOI: 10.2186/jpr.jpor_2019_336] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To evaluate the influence of quantity and positioning of veneered zirconia specimens during firing of porcelain on their fatigue performance and colorimetric differences. METHODS Bilayer discs (Ø=15 mm) were made, following ISO 6872 guidelines, using a Y-TZP core (yttria-stabilized tetragonal zirconia polycrystal ceramic; VITA In-Ceram YZ) and a feldspathic veneering material (VITA VM9), being both layers with 0.7 mm thickness. Y-TZP discs were sintered, the veneering material was applied over it, and the bilayer specimens were fired according to two factors (n=20): 'quantity' (1 or 5 samples per firing cycle; G1 and G5 groups respectively) and 'positioning' of the specimens inside the furnace (center or periphery of the refractory tray; G5C and G5P groups, respectively). The CIEL*a*b* parameters were recorded with a spectrophotometer and the color difference (ΔE 00 ) and translucency (TP 00 ) were calculated using CIEDE2000 equations. The step-stress fatigue test was performed with the veneer facing down (region of tensile stress concentration), 10 Hz frequency, initial tension of 20 MPa for 5,000 cycles, followed by steps of 10,000 cycles using a step size of 10 MPa, up to 100 MPa; data from strength and number of cycles for failure were recorded for statistical analysis. RESULTS Unacceptable color differences (ΔE 00 >1.8) were observed comparing G5C vs. G1 (quantity) and G5C vs. G5P (positioning), meanwhile translucency parameters were not affected. Besides, only the 'quantity' factor influenced the fatigue performance (G1>G5C). None of the tested specimens survived beyond 90N and/or 75000 cycles. CONCLUSIONS The quantity and position of the specimens during firing influence the final color of porcelain-veneered zirconia, and firing one specimen per cycle improved the fatigue performance of the bilayer system.
Collapse
Affiliation(s)
- Pablo Soares Machado
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria
| | - Camila da Silva Rodrigues
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria
| | - Luís Felipe Guilardi
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria
| | - Marília Pivetta Rippe
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria
| |
Collapse
|
26
|
Diniz V, Condé Oliveira Prado PH, Meireles Rodrigues JV, Monteiro JB, Zucuni C, Valandro LF, Melo RM. Ceramic firing protocols and thermocycling: effects on the load-bearing capacity under fatigue of a bonded zirconia lithium silicate glass-ceramic. J Mech Behav Biomed Mater 2020; 110:103963. [DOI: 10.1016/j.jmbbm.2020.103963] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Revised: 06/24/2020] [Accepted: 06/28/2020] [Indexed: 12/19/2022]
|
27
|
Falahchai M, Babaee Hemmati Y, Neshandar Asli H, Neshandar Asli M. Marginal adaptation of zirconia‐reinforced lithium silicate overlays with different preparation designs. J ESTHET RESTOR DENT 2020; 32:823-830. [DOI: 10.1111/jerd.12642] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 07/21/2020] [Accepted: 07/30/2020] [Indexed: 12/01/2022]
Affiliation(s)
- Mehran Falahchai
- Dental Sciences Research Center, Department of Prosthodontics School of Dentistry, Guilan University of Medical Sciences Rasht Iran
| | - Yasamin Babaee Hemmati
- Dental Sciences Research Center, Department of Orthodontics School of Dentistry, Guilan University of Medical Sciences Rasht Iran
| | - Hamid Neshandar Asli
- Dental Sciences Research Center, Department of Prosthodontics School of Dentistry, Guilan University of Medical Sciences Rasht Iran
| | - Marzieh Neshandar Asli
- Undergraduate student, Dental School Anzali Campus, Guilan University of Medical Sciences Rasht Iran
| |
Collapse
|
28
|
Alves DM, Cadore-Rodrigues AC, Prochnow C, Burgo TADL, Spazzin AO, Bacchi A, Valandro LF, Rocha Pereira GK. Fatigue performance of adhesively luted glass or polycrystalline CAD-CAM monolithic crowns. J Prosthet Dent 2020; 126:119-127. [PMID: 32636073 DOI: 10.1016/j.prosdent.2020.03.032] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Revised: 03/23/2020] [Accepted: 03/23/2020] [Indexed: 11/17/2022]
Abstract
STATEMENT OF PROBLEM Data comparing the fatigue performance of adhesively luted glass or polycrystalline ceramic systems for computer-aided design and computer-aided manufacturing (CAD-CAM) are scarce. PURPOSE The purpose of this in vitro study was to evaluate and compare the fatigue performance of monolithic crowns manufactured from glass or polycrystalline CAD-CAM ceramic systems adhesively luted to a dentin analog. MATERIALS AND METHODS Fifty-four pairs of standardized preparations of dentin analog (NEMA Grade G10) and simplified ceramic crowns of 1.5-mm thickness were obtained with 3 ceramic materials: lithium disilicate (LD) glass-ceramic (IPS e.max CAD); zirconia-reinforced lithium silicate (ZLS) glass-ceramic (Vita Suprinity); and translucent yttrium fully stabilized polycrystalline zirconia (Trans YZ) (Prettau Anterior). The simplified crowns (n=15) were adhesively cemented onto the preparations and subjected to step-stress fatigue test (initial load of 400 N, 20 Hz, 10 000 cycles, followed by 100-N increment steps until failure). Collected data (fatigue failure load [FFL] and cycles for failure [CFF]) were submitted to survival analysis with the Kaplan-Meier and Mantel-Cox post hoc tests (α=.05) and to Weibull analysis (Weibull modulus and its respective 95% confidence interval). Failed crowns were submitted to fractography analysis. The surface characteristics of the internal surface (roughness, fractal dimension) of additional crowns were accessed, and the occlusal cement thickness obtained in each luted system was measured. RESULTS Trans YZ crowns presented the highest values of FFL, CFF, and survival rates, followed by ZLS and LD (mean FFL: 1740 N>1187 N>987 N; mean CFF: 149 000>92 613>73 667). Weibull modulus and cement thickness were similar for all tested materials. LD presented the roughest internal surface, followed by ZLS (mean Ra: 226 nm>169 nm>93 nm). The LD and ZLS internal surfaces also showed higher fractal dimension, pointing to a more complex surface topography (mean fractal dimension: 2.242=2.238>2.147). CONCLUSIONS CAD-CAM monolithic crowns of Trans YZ show the best fatigue performance. In addition, ZLS crowns also showed better performance than LD crowns.
Collapse
Affiliation(s)
- Daniela Meira Alves
- Post-Graduate Program in Dentistry, School of Dentistry, Meridional Faculty, IMED, Passo Fundo, Rio Grande do Sul, Brazil
| | - Ana Carolina Cadore-Rodrigues
- PhD student, MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Catina Prochnow
- MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Thiago Augusto de Lima Burgo
- Adjunct Professor, Department of Physics, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Aloísio Oro Spazzin
- Professor, Post-Graduate Program in Dentistry, School of Dentistry, Meridional Faculty, IMED, Passo Fundo, Rio Grande do Sul, Brazil
| | - Ataís Bacchi
- Professor, Post-Graduate Program in Dentistry, School of Dentistry, Meridional Faculty, IMED, Passo Fundo, Rio Grande do Sul, Brazil
| | - Luiz Felipe Valandro
- Professor, MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Gabriel Kalil Rocha Pereira
- Adjunct Professor, MSciD and PhD Post-Graduate Program in Oral Science (Prosthodontics Units), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil.
| |
Collapse
|
29
|
High load frequency at 20Hz: Its effects on the fatigue behavior of a leucite-reinforced glass-ceramic. J Mech Behav Biomed Mater 2020; 107:103769. [DOI: 10.1016/j.jmbbm.2020.103769] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 03/30/2020] [Accepted: 03/31/2020] [Indexed: 12/27/2022]
|
30
|
Falahchai M, Babaee Hemmati Y, Neshandar Asli H, Rezaei E. Effect of Tooth Preparation Design on Fracture Resistance of Zirconia‐Reinforced Lithium Silicate Overlays. J Prosthodont 2020; 29:617-622. [DOI: 10.1111/jopr.13160] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/05/2020] [Indexed: 11/28/2022] Open
Affiliation(s)
- Mehran Falahchai
- Dental Sciences Research Center, Department of Prosthodontics, School of DentistryGuilan University of Medical Sciences Rasht Iran
| | - Yasamin Babaee Hemmati
- Dental Sciences Research Center, Department of Orthodontics, School of DentistryGuilan University of Medical Sciences Rasht Iran
| | - Hamid Neshandar Asli
- Dental Sciences Research Center, Department of Prosthodontics, School of DentistryGuilan University of Medical Sciences Rasht Iran
| | - Elnaz Rezaei
- Dental Sciences Research Center, Department of Prosthodontics, School of DentistryGuilan University of Medical Sciences Rasht Iran
| |
Collapse
|
31
|
Zucuni CP, Ilha BD, May MM, May LG, Valandro LF. Grinding the intaglio surface of yttria partially- and fully-stabilized zirconia polycrystals restorations: Effect on their fatigue behavior. J Mech Behav Biomed Mater 2020; 109:103800. [PMID: 32347216 DOI: 10.1016/j.jmbbm.2020.103800] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Revised: 04/09/2020] [Accepted: 04/12/2020] [Indexed: 11/20/2022]
Abstract
This study evaluated the effects of diamond bur grinding the intaglio surface of second (yttria partially-stabilized zirconia polycrystals, PSZ) and third-generation zirconia (fully-stabilized zirconia polycrystals, FSZ) adhesively cemented to dentin analogue substrate on the fatigue failure load, cycle number until failure, surface micromorphology and phase transformation. Disc-shaped specimens were produced from second (Katana ML-HT, Kuraray) and third-generation zirconia (Katana STML, Kuraray) and randomly allocated (n = 15) into two groups according to the intaglio surface treatment: Control - Ctrl (without grinding); Grinding - Gr (grinding at the center of the intaglio surface). The ceramic discs were adhesively cemented (Multilink Automix System) onto dentin analogue discs. Fatigue tests were executed by the step-stress method. The obtained data were analyzed by Kaplan Meier and Mantel-Cox tests. In addition, surface topography, roughness, phase transformation and fractography analyses were performed. SEM analysis showed that grinding increased the surface roughness and introduced defects in zirconia from both generations. Grinding increased the fatigue failure load, number of cycles to failure and survival rates of the second-generation zirconia statistically (control: 1373.33 N < grinding: 1600 N), while these same outcomes were reduced by grinding for the third-generation zirconia significantly (control: 766.67 N > grinding: 620 N). Thus, clinical adjustments with diamond burs damage the fatigue behavior of adhesively cemented third-generation zirconia.
Collapse
Affiliation(s)
- Camila Pauleski Zucuni
- Faculty of Odontology, Federal University of Santa Maria, Santa Maria, State of Rio Grande do Sul, Brazil.
| | - Bruna Dias Ilha
- Faculty of Odontology, Federal University of Santa Maria, Santa Maria, State of Rio Grande do Sul, Brazil.
| | - Michele Mirian May
- Faculty of Odontology, Federal University of Santa Maria, Santa Maria, State of Rio Grande do Sul, Brazil.
| | - Liliana Gressler May
- Faculty of Odontology, Federal University of Santa Maria, Santa Maria, State of Rio Grande do Sul, Brazil.
| | - Luiz Felipe Valandro
- Faculty of Odontology, Federal University of Santa Maria, Santa Maria, State of Rio Grande do Sul, Brazil.
| |
Collapse
|
32
|
García-Engra G, Fernandez-Estevan L, Casas-Terrón J, Fons-Font A, Castelo-Baz P, Agustín-Panadero R, Román-Rodriguez JL. Fracture Resistance of New Metal-Free Materials Used for CAD-CAM Fabrication of Partial Posterior Restorations. Medicina (B Aires) 2020; 56:medicina56030132. [PMID: 32197479 PMCID: PMC7143083 DOI: 10.3390/medicina56030132] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2020] [Revised: 03/14/2020] [Accepted: 03/16/2020] [Indexed: 11/24/2022] Open
Abstract
Background and Objectives: To evaluate in vitro the fracture resistance and fracture type of computer-aided design and computer-aided manufacturing (CAD-CAM) materials. Materials and Methods: Discs were fabricated (10 × 1.5 mm) from four test groups (N = 80; N = 20 per group): lithium disilicate (LDS) group (control group): IPS e.max CAD®; zirconium-reinforced lithium silicate (ZRLS) group: VITA SUPRINITY®; polymer-infiltrated ceramic networks (PICN) group: VITA ENAMIC®; resin nanoceramics (RNC) group: LAVA™ ULTIMATE. Each disc was cemented (following the manufacturers’ instructions) onto previously prepared molar dentin. Samples underwent until fracture using a Shimadzu® test machine. The stress suffered by each material was calculated with the Hertzian model, and its behavior was analyzed using the Weibull modulus. Data were analyzed with ANOVA parametric statistical tests. Results: The LDS group obtained higher fracture resistance (4588.6 MPa), followed by the ZRLS group (4476.3 MPa) and PICN group (4014.2 MPa) without statistically significant differences (p < 0.05). Hybrid materials presented lower strength than ceramic materials, the RNC group obtaining the lowest values (3110 MPa) with significant difference (p < 0.001). Groups PICN and RNC showed greater occlusal wear on the restoration surface prior to star-shaped fracture on the surface, while other materials presented radial fracture patterns. Conclusion: The strength of CAD-CAM materials depended on their composition, lithium disilicate being stronger than hybrid materials.
Collapse
Affiliation(s)
- Georgina García-Engra
- Prosthodontics and Occlusion Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46021 Valencia, Spain; (G.G.-E.); (J.C.-T.); (A.F.-F.); (R.A.-P.); (J.L.R.-R.)
| | - Lucia Fernandez-Estevan
- Prosthodontics and Occlusion Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46021 Valencia, Spain; (G.G.-E.); (J.C.-T.); (A.F.-F.); (R.A.-P.); (J.L.R.-R.)
- Correspondence: ; Tel.: +34-963-864-034
| | - Javier Casas-Terrón
- Prosthodontics and Occlusion Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46021 Valencia, Spain; (G.G.-E.); (J.C.-T.); (A.F.-F.); (R.A.-P.); (J.L.R.-R.)
| | - Antonio Fons-Font
- Prosthodontics and Occlusion Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46021 Valencia, Spain; (G.G.-E.); (J.C.-T.); (A.F.-F.); (R.A.-P.); (J.L.R.-R.)
| | - Pablo Castelo-Baz
- Co-director of Master’s Program in Endodontics, Restorative Dentistry, and Dental Esthetics, University of Santiago de Compostela, 15782 Santiago de Compostela, Spain;
| | - Rubén Agustín-Panadero
- Prosthodontics and Occlusion Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46021 Valencia, Spain; (G.G.-E.); (J.C.-T.); (A.F.-F.); (R.A.-P.); (J.L.R.-R.)
| | - Juan Luis Román-Rodriguez
- Prosthodontics and Occlusion Unit, Department of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46021 Valencia, Spain; (G.G.-E.); (J.C.-T.); (A.F.-F.); (R.A.-P.); (J.L.R.-R.)
| |
Collapse
|
33
|
Zucuni CP, Pereira GKR, Valandro LF. Grinding, polishing and glazing of the occlusal surface do not affect the load-bearing capacity under fatigue and survival rates of bonded monolithic fully-stabilized zirconia simplified restorations. J Mech Behav Biomed Mater 2020; 103:103528. [DOI: 10.1016/j.jmbbm.2019.103528] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Revised: 11/06/2019] [Accepted: 11/11/2019] [Indexed: 10/25/2022]
|
34
|
Miranda JS, Barcellos ASDP, Campos TMB, Cesar PF, Amaral M, Kimpara ET. Effect of repeated firings and staining on the mechanical behavior and composition of lithium disilicate. Dent Mater 2020; 36:e149-e157. [PMID: 32061444 DOI: 10.1016/j.dental.2020.02.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Revised: 09/02/2019] [Accepted: 02/04/2020] [Indexed: 11/17/2022]
Abstract
OBJECTIVE To evaluate the composition, flexural strength and fatigue behaviour of lithium disilicate ceramic (LD) after repeated firings and different staining techniques. METHODS LD discs were fabricated and divided according to number of firing cycles and staining technique: CO - control, discs were crystallized (850°C/10min); SC - single-step characterization - crystallization and staining (applied with a thin brush) were performed in a single step with one firing cycle (850°C/10min); and DC - double-step characterization - crystallization firing cycle was performed first (850°C/10min), followed by staining firing cycle (770°C/90s). Specimens were fired two, four or six times (one crystallization firing cycle and one, three or five staining firing cycles), resulting into 9 groups (n=30): COII, COIV, COVI, SCII, SCIV, SCVI, DCII, DCIV and DCVI. The composition of the specimens was investigated (EDS, XRD, Raman spectroscopy), and the biaxial flexural strength (n=10) and staircase tests (n=20, 5×104 cycles, 5Hz) were performed. Data were subjected to one-way ANOVA and Tukey's test (α=0.05). RESULTS EDS and XRD revealed amorphous content for stained groups. Biaxial flexural strength was not affected by repeated firings in any group, but stained groups presented lower flexural strength than control groups (p=0.001). The fatigue limit results decreased in all groups compared to flexural strength. SC groups showed similar (SCII and SCIV) or even higher fatigue limits (SCVI) than the control groups, and DC showed the lowest fatigue limit values. SEM and Raman suggested that the interfaces between staining and the LD showed only an overlap for the DC groups, whereas for the SC it was suggested an interaction between the stain and the LD. SIGNIFICANCE Repeated firings did not result in decreased lithium disilicate flexural strength.Staining affected flexural strength and also resulted in increased amorphous content in the characterized specimens. Single-step staining resulted in the highest fatigue limit.
Collapse
Affiliation(s)
- Jean Soares Miranda
- Institute of Science and Technology, UNESP - Paulista State University, São José dos Campos, São Paulo, Brazil
| | | | | | | | - Marina Amaral
- Department of Dentistry, University of Taubaté, Taubaté, São Paulo, Brazil
| | - Estevão Tomomitsu Kimpara
- Institute of Science and Technology, UNESP - Paulista State University, São José dos Campos, São Paulo, Brazil.
| |
Collapse
|
35
|
Sulaiman TA. Materials in digital dentistry—A review. J ESTHET RESTOR DENT 2020; 32:171-181. [DOI: 10.1111/jerd.12566] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2019] [Revised: 10/06/2019] [Accepted: 12/16/2019] [Indexed: 11/29/2022]
Affiliation(s)
- Taiseer A. Sulaiman
- Division Director of Operative Dentistry and Biomaterials, Department of Restorative SciencesUNC Adams School of Dentistry Chapel Hill North Carolina
| |
Collapse
|
36
|
Guilardi LF, Pereira GKR, Vallau AS, Silva IA, Giordani JC, Valandro LF, Rippe MP. Fatigue Failure Load of a Bonded Simplified Monolithic Feldspathic Ceramic: Influence of Hydrofluoric Acid Etching and Thermocycling. Oper Dent 2020; 45:E21-E31. [DOI: 10.2341/19-069-l] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective:
To evaluate the effect of hydrofluoric acid (HF) etching and thermocycling (Tc) on fatigue failure load of feldspathic ceramic restorations cemented with two resin cements.
Methods:
Disc-shaped feldspathic ceramic (Vitablocs Mark II; Ø=10 mm, 1.0-mm thick) and G10 epoxy resin (Ø=10 mm, 2.5-mm thick) specimens were made and randomly allocated considering three factors: ceramic etching (ie, with vs without 10% HF plus silane application), resin cement (ie, self-adhesive [RelyX U200; U200] or conventional [Multilink Automix; MA]), and Tc (ie, with vs without 5-55°C/12,000 cycles). Adhesive cementation followed each manufacturer's instructions. The fatigue test (n=20) was based on the staircase approach (250,000 cycles; 20 Hz). Contact angle, surface topography, and fractography analysis were also executed. Specific statistical tests were employed for each outcome (α=0.05).
Results:
The interaction of HF and Tc factors decreased the fatigue resistance for both cements (U200 542.63>U200/HF-Tc 495.00; MA 544.47>MA/HF-Tc 506.84). Comparing the cements associated with HF or Tc, there was statistical superiority for MA (U200-Tc 537.37<MA-Tc 561.32; U200/HF 535.79<MA/HF 557.11), and no statistical difference was detected when only cement type or its association with HF-Tc was compared (U200 542.63=MA 544.47; U200/HF-Tc 495.00=MA/HF-Tc 506.84). The fracture always originated from defects at the ceramic-intaglio surface as radial cracks.
Conclusion:
HF etching plus silane agent increased the ceramic surface free energy and its wettability, but it did not provide better results in terms of fatigue resistance compared with silane agent application only. The association of HF etching and aging significantly reduced the fatigue resistance of the material, regardless of the resin cement used.
Collapse
Affiliation(s)
- LF Guilardi
- Luís Felipe Guilardi, DDS, MSD, MSciD and PhD, Post-Graduate Program in Oral Sciences (Prosthodontics Units), School of Dentistry, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil
| | - GKR Pereira
- Gabriel Kalil Rocha Pereira, DDS, MSciD, PhD, Division of Prosthodontics, Department of Restorative Dentistry, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil
| | - AS Vallau
- Amanda da Silveira Vallau, DDS, Graduate Program in Dentistry, School of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - IA Silva
- Isadora Ames Silva, DDS, Graduate Program in Dentistry, School of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - JC Giordani
- João Carlos Giordani, DDS, Graduate Program in Dentistry, School of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil
| | - LF Valandro
- Luiz Felipe Valandro, DDS, MSciD, PhD, Division of Prosthodontics, Department of Restorative Dentistry, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil
| | - MP Rippe
- Marília Pivetta Rippe, DDS, MSciD, PhD, Division of Prosthodontics, Department of Restorative Dentistry, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul State, Brazil
| |
Collapse
|
37
|
Bergamo ET, Bordin D, Ramalho IS, Lopes AC, Gomes RS, Kaizer M, Witek L, Bonfante EA, Coelho PG, Del Bel Cury AA. Zirconia-reinforced lithium silicate crowns: Effect of thickness on survival and failure mode. Dent Mater 2019; 35:1007-1016. [DOI: 10.1016/j.dental.2019.04.007] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2018] [Revised: 02/12/2019] [Accepted: 04/12/2019] [Indexed: 10/26/2022]
|
38
|
Castelo-Baz P, Quijada-López S, Petrelli GB, Vila RM, Pérez-Heredia M, Martín-Biedma B. Surgical extrusion with biologically oriented preparation: An alternative to extraction. J Prosthet Dent 2019; 121:553-556. [PMID: 30878148 DOI: 10.1016/j.prosdent.2019.01.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2018] [Revised: 12/17/2018] [Accepted: 01/11/2019] [Indexed: 10/27/2022]
Abstract
Surgical extrusion should be considered as an alternative treatment in patients with structurally compromised teeth that retain coronal integrity and have favorable root anatomy. The procedure described is straightforward and can be performed quickly. A situation in which it was used to treat a maxillary premolar with substantial structural loss but well-preserved periodontal attachment is presented. The biologically oriented preparation technique is a conservative method of tooth restoration.
Collapse
Affiliation(s)
- Pablo Castelo-Baz
- Assistant Professor, Department of Endodontics and Restorative Dentistry, University of Santiago de Compostela, Santiago, Spain.
| | - Selenia Quijada-López
- Assistant Professor, Department of Endodontics and Restorative Dentistry, University of Santiago de Compostela, Santiago, Spain
| | - Germán Barbieri Petrelli
- Assistant Professor, Department of Periodontics, University of Santiago de Compostela, Santiago, Spain
| | - Ramón Miguéns Vila
- Assistant Professor, Department of Endodontics and Restorative Dentistry, University of Santiago de Compostela, Santiago, Spain
| | - Mercedes Pérez-Heredia
- Assistant Professor, Department of Endodontics and Restorative Dentistry, University of Granada, Granada, Spain
| | - Benjamín Martín-Biedma
- Professor, Department of Endodontics and Restorative Dentistry, University of Santiago de Compostela, Santiago, Spain
| |
Collapse
|
39
|
Lithium disilicate glass-ceramic vs translucent zirconia polycrystals bonded to distinct substrates: Fatigue failure load, number of cycles for failure, survival rates, and stress distribution. J Mech Behav Biomed Mater 2019; 91:122-130. [DOI: 10.1016/j.jmbbm.2018.12.010] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Revised: 12/09/2018] [Accepted: 12/12/2018] [Indexed: 11/21/2022]
|
40
|
Zucuni CP, Venturini AB, Prochnow C, Rocha Pereira GK, Valandro LF. Load-bearing capacity under fatigue and survival rates of adhesively cemented yttrium-stabilized zirconia polycrystal monolithic simplified restorations. J Mech Behav Biomed Mater 2019; 90:673-680. [DOI: 10.1016/j.jmbbm.2018.11.009] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Revised: 11/08/2018] [Accepted: 11/10/2018] [Indexed: 02/04/2023]
|
41
|
Dal Piva AMDO, Tribst JPM, Borges ALS, de Melo RM, Bottino MA. Influence of substrate design for in vitro mechanical testing. J Clin Exp Dent 2019; 11:e119-e125. [PMID: 30805115 PMCID: PMC6383903 DOI: 10.4317/jced.55353] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2018] [Accepted: 01/14/2019] [Indexed: 12/16/2022] Open
Abstract
Background The goal of this study was to evaluate the influence of dental substrate simulator material, and the presence of root and periodontal ligament on the stress distribution in an adhesively-cemented monolithic crown. Material and Methods Five (5) 3D models according to the substrate simulator material and shape were modeled with CAD software for conducting non-linear finite element analysis (FEA): Tooth with and without periodontal ligament - subgroup "pl" (groups Tooth+pl and Tooth-pl), machined tooth in epoxy-resin with and without pulp chamber - subgroup "pc" (ER+pc and ER-pc) and simplified epoxy-resin substrate without pulp chamber and roots (SiER). Next, adhesively-cemented monolithic crowns in zirconia reinforced lithium silicate were modeled over each substrate. The solids were then imported in STEP format to the analysis software and the contact between teeth and cylinder was considered perfectly bonded; whereas, the contacts involving the resin cement were considered as non-separated. The materials were considered isotropic, linearly elastic, and homogeneous. An axial load (600 N) was applied to the occlusal surface and results of maximum principal stress (MPa) on the restoration were required. Results FEA revealed that all evaluated subtracts showed the crown intaglio surface as the most stressed region. The average stress and stress peaks were similar for restorations cemented onto Tooth+pl, Tooth-pl and ER+pc substrates, but, 13% higher in comparison to ER-pc and SiER substrates. Conclusions Simplified substrates can be used to evaluate posterior full crown behavior without periodontal ligaments and roots, since the rigidity of the specimen is taken into account. Key words:Finite element analysis, axial loading, computed assisted numerical analisys, monolithic crowns,methodological study.
Collapse
Affiliation(s)
- Amanda-Maria-de Oliveira Dal Piva
- DDs, MSc, PhD Student, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil. Address: Av Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, Brazil. CEP 12245-000. Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan #3004, 1081 LA Amsterdam, Noord-Holland, The Netherlands
| | - João-Paulo-Mendes Tribst
- DDs, MSc, PhD Student, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil. Address: Av Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, Brazil. CEP 12245-000. Department of Dental Materials Science, Academic Centre for Dentistry Amsterdam (ACTA), Universiteit van Amsterdam and Vrije Universiteit, Gustav Mahlerlaan #3004, 1081 LA Amsterdam, Noord-Holland, The Netherlands
| | - Alexandre-Luiz-Souto Borges
- DDs, MSc, PhD, Adjunct Professor, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil. Address: Av Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, Brazil. CEP 12245-000
| | - Renata-Marques de Melo
- DDs, MSc, PhD, Researcher III, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil. Address: Av Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, Brazil. CEP 12245-000
| | - Marco-Antonio Bottino
- DDs, MSc, PhD, Professor, Department of Dental Materials and Proshodontics, São Paulo State University (Unesp), Institute of Science and Technology, São José dos Campos / SP, Brazil. Address: Av Engenheiro Francisco José Longo, 777, Jardim São Dimas, São José dos Campos, São Paulo, Brazil. CEP 12245-000
| |
Collapse
|
42
|
Prochnow C, Pereira GKR, Venturini AB, Scherer MM, Rippe MP, Bottino MC, Kleverlaan CJ, Valandro LF. How does hydrofluoric acid etching affect the cyclic load-to-failure of lithium disilicate restorations? J Mech Behav Biomed Mater 2018; 87:306-311. [DOI: 10.1016/j.jmbbm.2018.07.040] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2018] [Revised: 07/25/2018] [Accepted: 07/29/2018] [Indexed: 12/21/2022]
|
43
|
Hydrofluoric acid concentrations: Effect on the cyclic load-to-failure of machined lithium disilicate restorations. Dent Mater 2018; 34:e255-e263. [DOI: 10.1016/j.dental.2018.06.028] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2018] [Revised: 06/08/2018] [Accepted: 06/25/2018] [Indexed: 01/23/2023]
|