1
|
Martínez-Espinosa E, Vicente W, Salinas-Vázquez M, Ramírez-Cruz J. Numerical study of the effect of flow patterns on contaminant removal in a hospital ward with symmetrical and asymmetrical inlet port arrangements. THE SCIENCE OF THE TOTAL ENVIRONMENT 2025; 979:179439. [PMID: 40267647 DOI: 10.1016/j.scitotenv.2025.179439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2024] [Revised: 04/11/2025] [Accepted: 04/12/2025] [Indexed: 04/25/2025]
Abstract
The effect of flow patterns on contaminant removal in a hospital ward is studied numerically using the Reynolds Averaged Navier-Stokes (RANS) approach. Transient simulations are performed for three air changes and four ventilation systems. The contaminant is represented by a tracer gas (contaminant air) to study the airflow patterns, contaminant concentration, and contaminant removal in the hospital ward. The simulation is validated through two experimental studies using different ventilation systems, yielding a satisfactory agreement between the predictions and the experimental data. Numerical results indicate that flow patterns have a significant impact on the concentration and removal of contaminants, influenced by the building's geometry and the location of injection ports. In symmetrical arrangements of injection ports, the contamination concentration tends to be non-uniform in the x-z directions. The contaminant removal efficiency is the lowest (0.9322-0.9877) due to jet interference and the formation of dead zones by recirculation regions. In the asymmetrical arrangement of injection ports, the formation of recirculation zones in critical areas is inhibited, resulting in a more uniform contaminant concentration compared to other cases. The contaminant removal efficiency for the nine inlet ports presents the best performance (0.9944-0.99995), as jet interference is minimized and dead zones are eliminated. Furthermore, the overall concentration is <0.55 % for 9 ACH and 0.0048 % for 16 ACH in 1200 s. However, implementing more inlet ports (13) than in Case 3 affects the contaminant removal efficiency (0.9745-0.9991) due to jet interference. Therefore, according to the building geometry, a correct number of inlet ports and an appropriate distribution are essential in contaminant removal.
Collapse
Affiliation(s)
- E Martínez-Espinosa
- Industrial and Environmental Processes Department, Instituto de Ingeniería, UNAM, Ciudad Universitaria, 04510 Mexico City, Mexico.
| | - W Vicente
- Industrial and Environmental Processes Department, Instituto de Ingeniería, UNAM, Ciudad Universitaria, 04510 Mexico City, Mexico
| | - M Salinas-Vázquez
- Industrial and Environmental Processes Department, Instituto de Ingeniería, UNAM, Ciudad Universitaria, 04510 Mexico City, Mexico
| | | |
Collapse
|
2
|
Koshlak H, Lobanov L, Basok B, Hrabova T, Goncharov P. Plasma Photocatalysis: A Novel Approach for Enhanced Air Disinfection in Centralised Ventilation Systems. MATERIALS (BASEL, SWITZERLAND) 2025; 18:1870. [PMID: 40333573 PMCID: PMC12028752 DOI: 10.3390/ma18081870] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2025] [Revised: 04/04/2025] [Accepted: 04/14/2025] [Indexed: 05/09/2025]
Abstract
The COVID-19 pandemic highlighted the urgent need for sustainable and scalable air disinfection technologies in HVAC systems, addressing the limitations of energy-intensive and chemically intensive conventional methods. This study developed and evaluated a pilot experimental installation integrating plasma chemistry and photocatalysis for airborne pathogen and pollutant mitigation. The installation, designed with a modular architecture to simulate real-world HVAC dynamics, employed a bipolar plasma ioniser, a TiO2 photocatalytic module, and an adsorption-catalytic module for ozone abatement. Characterization techniques, including SEM and BET analysis, were used to evaluate the morphology and surface properties of the catalytic materials. Field tests in a production room demonstrated a 60% reduction in airborne microflora in three days, along with effective decomposition of ozone. The research also determined the optimal electrode geometry and interelectrode distance for stable corona discharge, which is essential for efficient plasma generation. Energy-efficient design considerations, which incorporate heat recovery and heat pump integration, achieved a 7-8-fold reduction in air heating energy consumption. These results demonstrate the potential of integrated plasma photocatalysis as a sustainable and scalable approach to enhance indoor air quality in centralised HVAC systems, contributing to both public health and energy efficiency.
Collapse
Affiliation(s)
- Hanna Koshlak
- Department of Sanitary Engineering, Kielce University of Technology, Aleja Tysiąclecia Państwa Polskiego, 7, 25-314 Kielce, Poland
| | - Leonid Lobanov
- E. O. Paton Electric Welding Institute NAS of Ukraine 11, K. Malevicha Str., 03150 Kyiv, Ukraine; (L.L.); (P.G.)
| | - Borys Basok
- Institute of Engineering Thermophysics of National Academy of Sciences of Ukraine, Marii Kapnist, 2a, 03057 Kyiv, Ukraine; (B.B.); (T.H.)
| | - Tetyana Hrabova
- Institute of Engineering Thermophysics of National Academy of Sciences of Ukraine, Marii Kapnist, 2a, 03057 Kyiv, Ukraine; (B.B.); (T.H.)
| | - Pavlo Goncharov
- E. O. Paton Electric Welding Institute NAS of Ukraine 11, K. Malevicha Str., 03150 Kyiv, Ukraine; (L.L.); (P.G.)
| |
Collapse
|
3
|
Li A, Mason K, Li Y, Bentley R. The challenges of quantifying the effects of housing on health using observational data. Ann Epidemiol 2025; 102:23-27. [PMID: 39746526 DOI: 10.1016/j.annepidem.2024.12.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2024] [Revised: 12/20/2024] [Accepted: 12/23/2024] [Indexed: 01/04/2025]
Abstract
Housing is an often overlooked yet fundamental social determinant of health. Like other social epidemiology exposures, housing faces a tension between the promise of modern causal inference methods and the messy reality of complex social processes and reliance on observational data. We use examples from over a decade of research to illustrate some of the key challenges in undertaking causally focused healthy housing research and demonstrate approaches that have been applied to address these challenges. We reflect on the improved understanding these approaches have delivered, and the key gaps and next steps in generating the evidence required to act on housing as a social determinant of health.
Collapse
Affiliation(s)
- Ang Li
- NHMRC Centre of Research Excellence in Healthy Housing, Centre for Health Policy, Melbourne School of Population and Global Health, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Australia.
| | - Kate Mason
- NHMRC Centre of Research Excellence in Healthy Housing, Centre for Health Policy, Melbourne School of Population and Global Health, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Australia
| | - Yuxi Li
- NHMRC Centre of Research Excellence in Healthy Housing, Centre for Health Policy, Melbourne School of Population and Global Health, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Australia
| | - Rebecca Bentley
- NHMRC Centre of Research Excellence in Healthy Housing, Centre for Health Policy, Melbourne School of Population and Global Health, Faculty of Medicine, Dentistry and Health Sciences, The University of Melbourne, Australia
| |
Collapse
|
4
|
Gong Z, Song T, Hu M, Che Q, Guo J, Zhang H, Li H, Wang Y, Liu B, Shi N. Natural and socio-environmental factors in the transmission of COVID-19: a comprehensive analysis of epidemiology and mechanisms. BMC Public Health 2024; 24:2196. [PMID: 39138466 PMCID: PMC11321203 DOI: 10.1186/s12889-024-19749-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Accepted: 08/09/2024] [Indexed: 08/15/2024] Open
Abstract
PURPOSE OF REVIEW There are significant differences in the transmission rate and mortality rate of COVID-19 under environmental conditions such as seasons and climates. However, the impact of environmental factors on the role of the COVID-19 pandemic and the transmission mechanism of the SARS-CoV-2 is unclear. Therefore, a comprehensive understanding of the impact of environmental factors on COVID-19 can provide innovative insights for global epidemic prevention and control policies and COVID-19 related research. This review summarizes the evidence of the impact of different natural and social environmental factors on the transmission of COVID-19 through a comprehensive analysis of epidemiology and mechanism research. This will provide innovative inspiration for global epidemic prevention and control policies and provide reference for similar infectious diseases that may emerge in the future. RECENT FINDINGS Evidence reveals mechanisms by which natural environmental factors influence the transmission of COVID-19, including (i) virus survival and transport, (ii) immune system damage, (iii) inflammation, oxidative stress, and cell death, and (iiii) increasing risk of complications. All of these measures appear to be effective in controlling the spread or mortality of COVID-19: (1) reducing air pollution levels, (2) rational use of ozone disinfection and medical ozone therapy, (3) rational exposure to sunlight, (4) scientific ventilation and maintenance of indoor temperature and humidity, (5) control of population density, and (6) control of population movement. Our review indicates that with the continuous mutation of SARS-CoV-2, high temperature, high humidity, low air pollution levels, and low population density more likely to slow down the spread of the virus.
Collapse
Affiliation(s)
- Zhaoyuan Gong
- Institute of Basic Research in Clinical Medicine, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Tian Song
- Institute of Basic Research in Clinical Medicine, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Mingzhi Hu
- Institute of Basic Research in Clinical Medicine, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Qianzi Che
- Institute of Basic Research in Clinical Medicine, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Jing Guo
- Institute of Basic Research in Clinical Medicine, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Haili Zhang
- Institute of Basic Research in Clinical Medicine, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Huizhen Li
- Institute of Basic Research in Clinical Medicine, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Yanping Wang
- Institute of Basic Research in Clinical Medicine, China Academy of Chinese Medical Sciences, Beijing, 100700, China.
| | - Bin Liu
- Institute of Basic Research in Clinical Medicine, China Academy of Chinese Medical Sciences, Beijing, 100700, China.
| | - Nannan Shi
- Institute of Basic Research in Clinical Medicine, China Academy of Chinese Medical Sciences, Beijing, 100700, China.
| |
Collapse
|
5
|
Arregui-Garcıa B, Ascione C, Pera A, Wang B, Stocco D, Carlson CJ, Bansal S, Valdano E, Pullano G. Disruption of outdoor activities caused by wildfires increases disease circulation. MEDRXIV : THE PREPRINT SERVER FOR HEALTH SCIENCES 2024:2024.08.08.24311678. [PMID: 39148844 PMCID: PMC11326313 DOI: 10.1101/2024.08.08.24311678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/17/2024]
Abstract
Although climate change poses a well-established risk to human health, present-day health impacts, particularly those resulting from climate-induced behavioral changes, are under-quantified. Analyzing the U.S. West Coast wildfires of September 2020, we found that poor air quality drives people indoors, increasing the circulation of airborne pathogens like COVID-19. Indoor masking rates as low as 10% can mitigate this risk, offering a clear path to enhance public health responses during wildfires.
Collapse
Affiliation(s)
- Beatriz Arregui-Garcıa
- Instituto de Fisica Interdisciplinary Sistemas Complejos IFISC (CSIC-UIB), Campus UIB, 07122 Palma de Mallorca, Spain
| | - Claudio Ascione
- Sorbonne Université, INSERM, Institut Pierre Louis d’Epidémiologie et de Santé Publique, F75012, Paris, France
| | - Arianna Pera
- Department of Computer Science, IT University of Copenhagen, Rued Langgaards Vej 7, 2300 Copenhagen, Denmark
| | - Boxuan Wang
- Sorbonne Université, INSERM, Institut Pierre Louis d’Epidémiologie et de Santé Publique, F75012, Paris, France
- EHESP French School of Public Health, F-35000 Rennes, France
| | - Davide Stocco
- Department of Mathematics, Politecnico di Milano, Via Bonardi 9, I-20133 Milan, Italy (IT)
| | - Colin J. Carlson
- Department of Epidemiology of Microbial Diseases & Yale Center on Climate Change and Health, Yale School of Public Health, New Haven, Connecticut, United States
| | - Shweta Bansal
- Department of Biology, Regents Hall, Georgetown University, 37th and O Streets NW, Washington, DC, 20057-1229, USA
| | - Eugenio Valdano
- Sorbonne Université, INSERM, Institut Pierre Louis d’Epidémiologie et de Santé Publique, F75012, Paris, France
| | - Giulia Pullano
- Department of Biology, Regents Hall, Georgetown University, 37th and O Streets NW, Washington, DC, 20057-1229, USA
| |
Collapse
|
6
|
Santos JF, del Rocío Silva-Calpa L, de Souza FG, Pal K. Central Countries' and Brazil's Contributions to Nanotechnology. CURRENT NANOMATERIALS 2024; 9:109-147. [DOI: 10.2174/2405461508666230525124138] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 02/09/2023] [Accepted: 03/14/2023] [Indexed: 01/05/2025]
Abstract
Abstract:
Nanotechnology is a cornerstone of the scientific advances witnessed over the past few
years. Nanotechnology applications are extensively broad, and an overview of the main trends
worldwide can give an insight into the most researched areas and gaps to be covered. This document
presents an overview of the trend topics of the three leading countries studying in this area, as
well as Brazil for comparison. The data mining was made from the Scopus database and analyzed
using the VOSviewer and Voyant Tools software. More than 44.000 indexed articles published
from 2010 to 2020 revealed that the countries responsible for the highest number of published articles
are The United States, China, and India, while Brazil is in the fifteenth position. Thematic
global networks revealed that the standing-out research topics are health science, energy,
wastewater treatment, and electronics. In a temporal observation, the primary topics of research are:
India (2020), which was devoted to facing SARS-COV 2; Brazil (2019), which is developing promising
strategies to combat cancer; China (2018), whit research on nanomedicine and triboelectric
nanogenerators; the United States (2017) and the Global tendencies (2018) are also related to the
development of triboelectric nanogenerators. The collected data are available on GitHub. This study
demonstrates the innovative use of data-mining technologies to gain a comprehensive understanding
of nanotechnology's contributions and trends and highlights the diverse priorities of nations in
this cutting-edge field.
Collapse
Affiliation(s)
- Jonas Farias Santos
- Programa de Engenharia da Nanotecnologia, COPPE, Centro de Tecnologia-Cidade Universitária, Universidade
Federal do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Leydi del Rocío Silva-Calpa
- Programa de Engenharia da Nanotecnologia, COPPE, Centro de Tecnologia-Cidade Universitária, Universidade
Federal do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Fernando Gomes de Souza
- Programa de Engenharia da Nanotecnologia, COPPE, Centro de Tecnologia-Cidade Universitária, Universidade
Federal do Rio de Janeiro, Rio de Janeiro, Brazil
- Instituto de Macromoléculas Professora Eloisa Mano, Centro de
Tecnologia-Cidade Universitária, Universidade Federal de Rio de Janeiro, Rio de Janeiro, Brazil
| | - Kaushik Pal
- University Center
for Research and Development (UCRD), Department of Physics, Chandigarh University, Ludhiana - Chandigarh State
Hwy, Mohali, Gharuan, 140413 Punjab, India
| |
Collapse
|
7
|
Hoisington AJ, Stearns-Yoder KA, Kovacs EJ, Postolache TT, Brenner LA. Airborne Exposure to Pollutants and Mental Health: A Review with Implications for United States Veterans. Curr Environ Health Rep 2024; 11:168-183. [PMID: 38457036 PMCID: PMC12070290 DOI: 10.1007/s40572-024-00437-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/16/2024] [Indexed: 03/09/2024]
Abstract
PURPOSE OF REVIEW Inhalation of airborne pollutants in the natural and built environment is ubiquitous; yet, exposures are different across a lifespan and unique to individuals. Here, we reviewed the connections between mental health outcomes from airborne pollutant exposures, the biological inflammatory mechanisms, and provide future directions for researchers and policy makers. The current state of knowledge is discussed on associations between mental health outcomes and Clean Air Act criteria pollutants, traffic-related air pollutants, pesticides, heavy metals, jet fuel, and burn pits. RECENT FINDINGS Although associations between airborne pollutants and negative physical health outcomes have been a topic of previous investigations, work highlighting associations between exposures and psychological health is only starting to emerge. Research on criteria pollutants and mental health outcomes has the most robust results to date, followed by traffic-related air pollutants, and then pesticides. In contrast, scarce mental health research has been conducted on exposure to heavy metals, jet fuel, and burn pits. Specific cohorts of individuals, such as United States military members and in-turn, Veterans, often have unique histories of exposures, including service-related exposures to aircraft (e.g. jet fuels) and burn pits. Research focused on Veterans and other individuals with an increased likelihood of exposure and higher vulnerability to negative mental health outcomes is needed. Future research will facilitate knowledge aimed at both prevention and intervention to improve physical and mental health among military personnel, Veterans, and other at-risk individuals.
Collapse
Affiliation(s)
- Andrew J Hoisington
- Veterans Affairs Rocky Mountain Mental Illness Research Education and Clinical Center (MIRECC), Rocky Mountain Regional Veterans Affairs Medical Center (RMR VAMC), Aurora, CO, 80045, USA.
- Military and Veteran Microbiome: Consortium for Research and Education (MVM-CoRE), Aurora, CO, 80045, USA.
- Department of Physical Medicine & Rehabilitation, University of Colorado Anschutz Medical Campus, Aurora, CO, 80045, USA.
- Department of Systems Engineering and Management, Air Force Institute of Technology, Wright-Patterson AFB, Dayton, OH, 45333, USA.
| | - Kelly A Stearns-Yoder
- Veterans Affairs Rocky Mountain Mental Illness Research Education and Clinical Center (MIRECC), Rocky Mountain Regional Veterans Affairs Medical Center (RMR VAMC), Aurora, CO, 80045, USA
- Military and Veteran Microbiome: Consortium for Research and Education (MVM-CoRE), Aurora, CO, 80045, USA
- Department of Physical Medicine & Rehabilitation, University of Colorado Anschutz Medical Campus, Aurora, CO, 80045, USA
| | - Elizabeth J Kovacs
- Department of Surgery, Division of GI, Trauma and Endocrine Surgery, and Burn Research Program, University of Colorado Anschutz Medical Campus, Aurora, CO, 80045, USA
- Veterans Affairs Research Service, RMR VAMC, Aurora, CO, 80045, USA
| | - Teodor T Postolache
- Veterans Affairs Rocky Mountain Mental Illness Research Education and Clinical Center (MIRECC), Rocky Mountain Regional Veterans Affairs Medical Center (RMR VAMC), Aurora, CO, 80045, USA
- Military and Veteran Microbiome: Consortium for Research and Education (MVM-CoRE), Aurora, CO, 80045, USA
- Mood and Anxiety Program, University of Maryland School of Medicine, Baltimore, MD, 21201, USA
- Department of Veterans Affairs, VISN 5 MIRECC, Baltimore, MD, 21201, USA
| | - Lisa A Brenner
- Veterans Affairs Rocky Mountain Mental Illness Research Education and Clinical Center (MIRECC), Rocky Mountain Regional Veterans Affairs Medical Center (RMR VAMC), Aurora, CO, 80045, USA
- Military and Veteran Microbiome: Consortium for Research and Education (MVM-CoRE), Aurora, CO, 80045, USA
- Department of Physical Medicine & Rehabilitation, University of Colorado Anschutz Medical Campus, Aurora, CO, 80045, USA
- Departments of Psychiatry & Neurology, University of Colorado Anschutz Medical Campus, Aurora, CO, 80045, USA
| |
Collapse
|
8
|
Ehelepola N, Thilakarathna HA. Respiratory infection transmission risk and indoor air quality at outpatient departments and emergency treatment units of Sri Lankan teaching hospitals. PLOS GLOBAL PUBLIC HEALTH 2024; 4:e0002862. [PMID: 38408038 PMCID: PMC10896534 DOI: 10.1371/journal.pgph.0002862] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Accepted: 01/04/2024] [Indexed: 02/28/2024]
Abstract
Indoor carbon dioxide (CO2) concentration has been used as a proxy of the degree of ventilation and, by extension, as an indicator of the risk of contracting respiratory infections. No publications exist regarding indoor air quality (IAQ) parameters of Sri Lankan hospitals.We measured the levels of CO2 and seven other IAQ parameters during morning rush hours for three days, in outpatient departments (OPDs) and emergency treatment units (ETUs) of all 21 teaching hospitals of Sri Lanka. We measured the same parameters of outdoor air also. We calculated the mean values of those parameters. We looked for correlations between outdoors and OPD and ETU levels of selected air quality parameters.The average CO2 levels of outdoors, OPDs and ETUs respectively were 514ppm (ppm = parts per million), 749ppm and 795ppm. The average levels of PM2.5 (particulate matter with diameters <2.5μm) outdoors, OPDs and ETUs respectively, were 28.7μg/m3,32μg/m3 and 25.6 μg/m3. The average levels of PM10 (particulate matter with diameters <10μm) outdoors, OPDs and ETUs respectively, were 49.4μg/m3, 55.5μg/m3 and 47.9 μg/m3. The median levels of formaldehyde outdoors, OPDs and ETUs respectively, were 0.03mg/m3, 0.04mg/m3 and 0.08mg/m3. The median levels of total volatile organic compounds (VOC) outdoors, OPDs and ETUs respectively were 0.12mg/m3, 0.19mg/m3 and 0.38mg/m3.CO2 levels of air in OPDs and ETUs generally were below the national ceilings but above the ceilings used by some developed countries. Outdoors, OPDs and ETUs air contain PM10, PM2.5 levels higher than WHO ceilings, although below the national ceilings. VOC and formaldehyde levels are generally below the national ceilings. Air in OPDs and ETUs is hotter and humid than national ceilings. Outdoor PM10, PM2.5 levels influence OPDs and ETUs levels. We propose methods to reduce the risk of nosocomial respiratory infections and to improve IAQ of Sri Lankan OPDs and ETUs.
Collapse
|
9
|
Xia Y, Lyu S. Direct numerical simulation of contaminant removal in presence of underfloor air distribution system. Heliyon 2024; 10:e24331. [PMID: 38298735 PMCID: PMC10827751 DOI: 10.1016/j.heliyon.2024.e24331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 12/07/2023] [Accepted: 01/07/2024] [Indexed: 02/02/2024] Open
Abstract
Indoor contaminant removal over 0.5 ≤ FrT ≤ 5.0, 0.5 ≤ N ≤ 5.0, and 50 ≤ Re ≤ 500 was investigated numerically, wherein FrT refers to the Froude number, N refers to the buoyancy ratio, and Re refers to the Reynolds number. As demonstrated, the ventilation effectiveness increased with increasing contaminant source intensity and air supply intensity at a constant air temperature, indicating that increase the fresh air can effectively eliminate contaminants in this case. At high air supply temperatures, the heat retention time and contaminant transport was extremely short, and the fresh air induced by strong natural convection floating lift was rapidly discharged. Additioanlly, the air supply intensity had significant effects on contaminant removal. Quantification of the ventilation effectiveness under the combined effects of air supply intensity, air supply temperature and contaminant source intensity was determined based on the results of direct numerical simulations.
Collapse
Affiliation(s)
- Yaowen Xia
- Key Laboratory of Rural Energy Engineering of Yunnan and Solar Energy Research Institute, Yunnan Normal University, Kunming, Yunnan, 650092, China
| | - Saidong Lyu
- Key Laboratory of Rural Energy Engineering of Yunnan and Solar Energy Research Institute, Yunnan Normal University, Kunming, Yunnan, 650092, China
| |
Collapse
|
10
|
Chawla H, Anand P, Garg K, Bhagat N, Varmani SG, Bansal T, McBain AJ, Marwah RG. A comprehensive review of microbial contamination in the indoor environment: sources, sampling, health risks, and mitigation strategies. Front Public Health 2023; 11:1285393. [PMID: 38074709 PMCID: PMC10701447 DOI: 10.3389/fpubh.2023.1285393] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 10/25/2023] [Indexed: 12/18/2023] Open
Abstract
The quality of the indoor environment significantly impacts human health and productivity, especially given the amount of time individuals spend indoors globally. While chemical pollutants have been a focus of indoor air quality research, microbial contaminants also have a significant bearing on indoor air quality. This review provides a comprehensive overview of microbial contamination in built environments, covering sources, sampling strategies, and analysis methods. Microbial contamination has various origins, including human occupants, pets, and the outdoor environment. Sampling strategies for indoor microbial contamination include air, surface, and dust sampling, and various analysis methods are used to assess microbial diversity and complexity in indoor environments. The review also discusses the health risks associated with microbial contaminants, including bacteria, fungi, and viruses, and their products in indoor air, highlighting the need for evidence-based studies that can relate to specific health conditions. The importance of indoor air quality is emphasized from the perspective of the COVID-19 pandemic. A section of the review highlights the knowledge gap related to microbiological burden in indoor environments in developing countries, using India as a representative example. Finally, potential mitigation strategies to improve microbiological indoor air quality are briefly reviewed.
Collapse
Affiliation(s)
- Hitikk Chawla
- Institute for Cell Biology and Neuroscience, Goethe University Frankfurt, Frankfurt, Germany
| | - Purnima Anand
- Department of Microbiology, Bhaskaracharya College of Applied Sciences, University of Delhi, New Delhi, India
| | - Kritika Garg
- Department of Biosciences and Bioengineering, Indian Institute of Technology Roorkee, Roorkee, India
| | - Neeru Bhagat
- Department of Microbiology, Bhaskaracharya College of Applied Sciences, University of Delhi, New Delhi, India
| | - Shivani G. Varmani
- Department of Biomedical Science, Bhaskaracharya College of Applied Sciences, University of Delhi, New Delhi, India
| | - Tanu Bansal
- Department of Biochemistry, All India Institute of Medical Sciences, New Delhi, India
| | - Andrew J. McBain
- School of Health Sciences, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, United Kingdom
| | - Ruchi Gulati Marwah
- Department of Microbiology, Bhaskaracharya College of Applied Sciences, University of Delhi, New Delhi, India
| |
Collapse
|
11
|
Liu H, Liu Z, He J, Hu C, Rong R, Han H, Wang L, Wang D. Reducing airborne transmission of SARS-CoV-2 by an upper-room ultraviolet germicidal irradiation system in a hospital isolation environment. ENVIRONMENTAL RESEARCH 2023; 237:116952. [PMID: 37619635 DOI: 10.1016/j.envres.2023.116952] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 08/08/2023] [Accepted: 08/21/2023] [Indexed: 08/26/2023]
Abstract
Upper-room ultraviolet germicidal irradiation (UVGI) technology can potentially inhibit the transmission of airborne disease pathogens. There is a lack of quantitative evaluation of the performance of the upper-room UVGI for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) airborne transmission under the combined effects of ventilation and UV irradiation. Therefore, this study aimed to explore the performance of the upper-room UVGI system for reducing SARS-CoV-2 virus transmission in a hospital isolation environment. Computational fluid dynamics and virological data on SARS-CoV-2 were integrated to obtain virus aerosol exposure in the hospital isolation environment containing buffer rooms, wards and bathrooms. The UV inactivation model was applied to investigate the effects of ventilation rate, irradiation flux and irradiation height on the upper-room UVGI performance. The results showed that increasing ventilation rate from 8 to 16 air changes per hour (ACH) without UVGI obtained 54.32% and 45.63% virus reduction in the wards and bathrooms, respectively. However, the upper-room UVGI could achieve 90.43% and 99.09% virus disinfection, respectively, with the ventilation rate of 8 ACH and the irradiation flux of 10 μW cm-2. Higher percentage of virus could be inactivated by the upper-room UVGI at a lower ventilation rate; the rate of improvement of UVGI elimination effect slowed down with the increase of irradiation flux. Increase irradiation height at lower ventilation rate was more effective in improving the UVGI performance than the increase in irradiation flux at smaller irradiation height. These results could provide theoretical support for the practical application of UVGI in hospital isolation environments.
Collapse
Affiliation(s)
- Haiyang Liu
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China
| | - Zhijian Liu
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China.
| | - Junzhou He
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China
| | - Chenxing Hu
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing, 100081, China
| | - Rui Rong
- Department of Power Engineering, North China Electric Power University, Baoding, Hebei, 071003, PR China
| | - Hao Han
- State Key Laboratory of NBC Protection for Civilian, Beijing, 100191, China.
| | - Lingyun Wang
- State Key Laboratory of NBC Protection for Civilian, Beijing, 100191, China
| | - Desheng Wang
- State Key Laboratory of NBC Protection for Civilian, Beijing, 100191, China
| |
Collapse
|
12
|
Park S, Mistrick R, Sitzabee W, Rim D. Effect of ventilation strategy on performance of upper-room ultraviolet germicidal irradiation (UVGI) system in a learning environment. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 899:165454. [PMID: 37467991 DOI: 10.1016/j.scitotenv.2023.165454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 06/22/2023] [Accepted: 07/08/2023] [Indexed: 07/21/2023]
Abstract
Upper-room ultraviolet germicidal irradiation (UVGI) system is recently in the limelight as a potentially effective method to mitigate the risk of airborne virus infection in indoor environments. However, few studies quantitatively evaluated the relationship between ventilation effectiveness and virus disinfection performance of a UVGI system. The objective of this study is to investigate the effects of ventilation strategy on detailed airflow distributions and UVGI disinfection performance in an occupied classroom. Three-dimensional computational fluid dynamics (CFD) simulations were performed for representative cooling, heating, and ventilation scenarios. The results show that when the ventilation rate is 1.1 h-1 (the minimum ventilation rate based on ASHRAE 62.1), enhancing indoor air circulation with the mixing fan notably improves the UVGI disinfection performance, especially for cooling with displacement ventilation and all-air-heating conditions. However, increasing indoor air mixing yields negligible effect on the disinfection performance for forced-convection cooling condition. The results also reveal that regardless of indoor thermal condition, disinfection effectiveness of a UVGI system increases as ventilation effectiveness is close to unity. Moreover, when the room average air speed is >0.1 m/s, upper-room UVGI system could yield about 90% disinfection effect for the aerosol size of 1 μm-10 μm. The findings of this study imply that upper-room UVGI systems in indoor environments (i.e., classrooms, hospitals) should be designed considering ventilation strategy and occupancy conditions, especially for occupied buildings with insufficient air mixing throughout the space.
Collapse
Affiliation(s)
- Seongjun Park
- Department of Architectural Engineering, Pennsylvania State University, United States of America.
| | - Richard Mistrick
- Architectural Engineering Department, Pennsylvania State University, 104 Engineering Unit A, University Park, PA 16802, United States of America.
| | - William Sitzabee
- Pennsylvania State University, 201 Physical Plant Building, University Park, PA 16802, United States of America.
| | - Donghyun Rim
- Architectural Engineering Department, Pennsylvania State University, 222 Engineering Unit A, University Park, PA 16802, United States of America.
| |
Collapse
|
13
|
Kumar S, Klassen M, Klassen D, Hardin R, King MD. Dispersion of sneeze droplets in a meat facility indoor environment - Without partitions. ENVIRONMENTAL RESEARCH 2023; 236:116603. [PMID: 37454802 DOI: 10.1016/j.envres.2023.116603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2022] [Revised: 06/26/2023] [Accepted: 07/07/2023] [Indexed: 07/18/2023]
Abstract
Spreading patterns of the coronavirus disease (COVID-19) showed that infected and asymptotic carriers both played critical role in escalating transmission of virus leading to global pandemic. Indoor environments of restaurants, classrooms, hospitals, offices, large assemblies, and industrial installations are susceptible to virus outbreak. Industrial facilities such as fabrication rooms of meat processing plants, which are laden with moisture and fat in indoor air are the most sensitive spaces. Fabrication room workers standing next to each other are exposed to the risk of long-range viral droplets transmission within the facility. An asymptomatic carrier may transmit the virus unintentionally to fellow workers through sporadic sneezing leading to community spread. A novel Computational Fluid Dynamics (CFD) model of a fabrication room with typical interior (stationary objects) was prepared and investigated. Study was conducted to identify indoor airflow patterns, droplets spreading patterns, leading droplets removal mechanism, locations causing maximum spread of droplets, and infection index for workers along with stationary objects in reference to seven sneeze locations covering the entire room. The role of condensers, exhaust fans and leakage of indoor air through large and small openings to other rooms was investigated. This comprehensive study presents flow scenarios in the facility and helps identify locations that are potentially at lower or higher risk for exposure to COVID-19. The results presented in this study are suitable for future engineering analyses aimed at redesigning public spaces and common areas to minimize the spread of aerosols and droplets that may contain pathogens.
Collapse
Affiliation(s)
- Sunil Kumar
- Department of Biological and Agricultural Engineering, Texas A&M University, College Station, TX 77843, USA.
| | | | - David Klassen
- Department of Mechanical Engineering, University of Calgary, Calgary, Alberta, T2N 1N4, Canada
| | - Robert Hardin
- Department of Biological and Agricultural Engineering, Texas A&M University, College Station, TX 77843, USA
| | - Maria D King
- Department of Biological and Agricultural Engineering, Texas A&M University, College Station, TX 77843, USA.
| |
Collapse
|
14
|
HAKIM H, KADOTA C, HASAN MA, MIYAOKA Y, KABIR MH, SHOHAM D, MURAKAMI H, TAKEHARA K. Evaluation of antimicrobial efficacies of chlorine dioxide gas released into the air towards pathogens present on the surfaces of inanimate objects. J Vet Med Sci 2023; 85:950-955. [PMID: 37482423 PMCID: PMC10539825 DOI: 10.1292/jvms.23-0205] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Accepted: 07/10/2023] [Indexed: 07/25/2023] Open
Abstract
The efficacy of ClO2 gas, as surface disinfectant at around 1,000 ppb against avian orthoavulaviruses type 1 (AOAV-1), infectious bronchitis virus (IBV), Escherichia coli (EC), and Salmonella Enteritidis (SE) was evaluated at the required level (≥99.9% reduction) on various surfaces. Exposing the surfaces to ClO2 gas for 1 hr reduced AOAV-1, except for rayon sheets which required 3 hr. However, 1 hr of exposure did not effectively reduced IBV titer. In the case of EC, glass plates and plastic carriers needed 1 hr of exposure, while rayon sheets required 2 hr. SE on rayon sheets required 1 hr exposure, but on the other tested surfaces showed inadequate reduction. Overall, ClO2 gas is an effective disinfectant for poultry farms.
Collapse
Affiliation(s)
- Hakimullah HAKIM
- Laboratory of Animal Health, Cooperative Division of Veterinary Sciences, Graduate School of Agriculture, Tokyo University of Agriculture and Technology, Tokyo,
Japan
| | - Chisaki KADOTA
- Laboratory of Animal Health, Department of Veterinary Medicine, Faculty of Agriculture, Tokyo University of Agriculture and Technology, Tokyo, Japan
| | - Md. Amirul HASAN
- Laboratory of Animal Health, Cooperative Division of Veterinary Sciences, Graduate School of Agriculture, Tokyo University of Agriculture and Technology, Tokyo,
Japan
| | - Yu MIYAOKA
- Laboratory of Animal Health, Cooperative Division of Veterinary Sciences, Graduate School of Agriculture, Tokyo University of Agriculture and Technology, Tokyo,
Japan
| | - Md. Humayun KABIR
- Laboratory of Animal Health, Cooperative Division of Veterinary Sciences, Graduate School of Agriculture, Tokyo University of Agriculture and Technology, Tokyo,
Japan
| | - Dany SHOHAM
- Bar-Ilan University, Begin-Sadat Center for Strategic Studies, Ramat Gan, Israel
| | - Harumi MURAKAMI
- Laboratory of Animal Health, Cooperative Division of Veterinary Sciences, Graduate School of Agriculture, Tokyo University of Agriculture and Technology, Tokyo,
Japan
- Laboratory of Animal Health, Department of Veterinary Medicine, Faculty of Agriculture, Tokyo University of Agriculture and Technology, Tokyo, Japan
| | - Kazuaki TAKEHARA
- Laboratory of Animal Health, Cooperative Division of Veterinary Sciences, Graduate School of Agriculture, Tokyo University of Agriculture and Technology, Tokyo,
Japan
- Laboratory of Animal Health, Department of Veterinary Medicine, Faculty of Agriculture, Tokyo University of Agriculture and Technology, Tokyo, Japan
| |
Collapse
|
15
|
Kusama T, Takeuchi K, Tamada Y, Kiuchi S, Osaka K, Tabuchi T. Compliance Trajectory and Patterns of COVID-19 Preventive Measures, Japan, 2020-2022. Emerg Infect Dis 2023; 29:1747-1756. [PMID: 37487165 PMCID: PMC10461672 DOI: 10.3201/eid2909.221754] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/26/2023] Open
Abstract
COVID-19 remains a global health threat. Compliance with nonpharmaceutical interventions is essential because of limited effectiveness of COVID-19 vaccines, emergence of highly contagious variants, and declining COVID-19 antibody titers over time. We evaluated compliance with 14 nonpharmaceutical intervention-related COVID-19 preventive behaviors, including mask wearing, ventilation, and surface sanitation, in a longitudinal study in Japan using 4 waves of Internet survey data obtained during 2020-2022. Compliance with most preventive behaviors increased or remained stable during the 2-year period, except for surface sanitation and going out behaviors; compliance with ventilation behavior substantially decreased in winter. Compliance patterns identified from latent class analysis showed that the number of persons in the low compliance class decreased, whereas those in the personal hygiene class increased. Our findings reflect the relaxation of mobility restriction policy in Japan, where the COVID-19 pandemic continues. Policymakers should consider behavioral changes caused by new policies to improve COVID-19 prevention strategies.
Collapse
|
16
|
Mao Y, Wang S, Liang J, Mao S, Han Y, Zhang S. Stratum Ventilation: Enabling Simultaneous Energy Conservation and Air Purification in Subway Cars. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:14521. [PMID: 36361400 PMCID: PMC9659082 DOI: 10.3390/ijerph192114521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 10/30/2022] [Accepted: 11/03/2022] [Indexed: 06/16/2023]
Abstract
The supply of fresh air for underground rail transit systems is not as simple as opening windows, which is a conventional ventilation (CV) measure adopted in aboveground vehicles. This study aims to improve contaminant dilution and air purification in subway car ventilation systems and the safety of rail transit post-coronavirus disease pandemic era. We designed an air conditioning (AC) terminal system combined with stratum ventilation (SV) to enable energy consumption reduction for subway cars. We experimentally tested the effectiveness of a turbulence model to investigate ventilation in subway cars. Further, we compared the velocity fields of CV and SV in subway cars to understand the differences in their airflow organizations and contaminant removal efficiencies, along with the energy savings of four ventilation scenarios, based on the calculations carried out using computational fluid dynamics. At a ventilation flow rate of 7200 m3/h, the CO2 concentration and temperature in the breathing areas of seated passengers were better in the SV than in the CV at a rate of 8500 m3/h. Additionally, the energy-saving rate of SV with AC cooling was 14.05%. The study provides new ideas for reducing the energy consumption of rail transit and broadens indoor application scenarios of SV technology.
Collapse
|
17
|
Núñez-Delgado A, Ahmed W, Bontempi E, Domingo JL. The environment, epidemics, and human health. ENVIRONMENTAL RESEARCH 2022; 214:113931. [PMID: 35921907 PMCID: PMC9339168 DOI: 10.1016/j.envres.2022.113931] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In this editorial piece, the Editors of the Virtual Special Issue (VSI) "The environment, epidemics, and human health" comment on the papers accepted for publication, which were selected after peer-reviewing among all those manuscripts submitted to the Special Issue. In view of the title of the VSI, it is clear that its aim goes beyond the COVID-19 pandemic, trying to explore relations among environmental aspects, any kind of epidemics, and human health. However, COVID-19 is still hitting as a global and current main issue, causing that manuscripts dealing with this disease and the SARS-CoV-2 virus are of high relevance in the whole set of research papers published.
Collapse
Affiliation(s)
- Avelino Núñez-Delgado
- Dept. Soil Sci. and Agric. Chem., Univ. Santiago de Compostela, Engineering Polytechnic School, Campus Univ. S/n, 27002, Lugo, Spain.
| | - Warish Ahmed
- CSIRO Land and Water, Ecosciences Precinct, 41 Boggo Road, Qld, 4102, Australia
| | - Elza Bontempi
- INSTM and University of Brescia, Via Branze 38, 25123, Brescia, Italy
| | - José L Domingo
- Laboratory of Toxicology and Environmental Health, School of Medicine, Universitat Rovira I Virgili, Reus, Spain
| |
Collapse
|