1
|
Tokeshi M. Microfluidic paper-based analytical devices: proven applications and future prospects in therapeutic drug monitoring, homeland security, and chemical education. ANAL SCI 2025:10.1007/s44211-025-00758-0. [PMID: 40253480 DOI: 10.1007/s44211-025-00758-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2025] [Accepted: 03/24/2025] [Indexed: 04/21/2025]
Abstract
Since the report by Whitesides et al. in 2007 on paper-based microfluidic analytical devices (μPADs), numerous studies have been published. The characteristics of μPADs, such as low cost, simplicity, and suitability for resource-limited settings, make them promising for a wide range of applications, including medical diagnostics, environmental analysis, and food testing. While these applications have been well-documented, this review focuses on the less common applications in therapeutic drug monitoring, homeland security, and chemical education. Specifically, the μPADs discussed in this review were developed for the determination of lithium ions in blood for therapeutic drug monitoring, the determination of the nerve agent VX for homeland security, and the measurement of ascorbic acid and pH for chemical education.
Collapse
Affiliation(s)
- Manabu Tokeshi
- Division of Applied Chemistry, Faculty of Engineering, Hokkaido University, Kita 13 Nishi 8, Kita-Ku, Sapporo, 060-8628, Japan.
- Innovative Research Center for Preventive Medical Engineering, Nagoya University, Furo-Cho, Chikusa-Ku, Nagoya, 464-8603, Japan.
- Institute of Nano-Life-Systems, Institutes of Innovation for Future Society, Nagoya University, Furo-Cho, Chikusa-Ku, Nagoya, 464-8603, Japan.
| |
Collapse
|
2
|
Pai S, Binu A, Lavanya GS, Harikumar M, Kedlaya Herga S, Citartan M, Mani NK. Advancements of paper-based microfluidics and organ-on-a-chip models in cosmetics hazards. RSC Adv 2025; 15:10319-10335. [PMID: 40182506 PMCID: PMC11966604 DOI: 10.1039/d4ra07336c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2024] [Accepted: 03/19/2025] [Indexed: 04/05/2025] Open
Abstract
Cosmetics have been used in society for centuries for beautification and personal hygiene maintenance. Modern cosmetics include various makeup, hair, and skincare products that range from moisturizers and shampoos to lipsticks and foundations and have become a quintessential part of our daily grooming activities. However, dangerous adulterants are added during the production of these cosmetics, which range from heavy metals to microbial contaminants. These adulterants not only reduce the quality and efficacy of cosmetic products but also pose a significant risk to human health. Detecting the presence of adulterants in cosmetics is crucial for regulating substandard cosmetic products in the industry. The conventional methods to detect such adulterants and quality testing are expensive and take a lot of effort, particularly when involving advanced analytical detection and clinical trials. Recently, efficient methods such as microfluidic methods have emerged to detect adulterants rapidly. In this review, we mainly focus on various adulterants present in cosmetics and their detection using paper-based microfluidic devices. In addition, this review also sheds light on the organ-on-a-chip model with the goal of developing a human tissue model for cosmetic testing. Combined, these approaches provide an efficient, inexpensive, and sustainable approach for quality testing in the cosmetics industry.
Collapse
Affiliation(s)
- Sanidhya Pai
- Technical University of Munich, Campus Straubing for Biotechnology and Sustainability Straubing Germany
| | - Amanda Binu
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal Karnataka 576104 India
| | - G S Lavanya
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal Karnataka 576104 India
| | - Meenakshi Harikumar
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal Karnataka 576104 India
| | - Srikrishna Kedlaya Herga
- Department of Public Health Genomics, Manipal School of Life Sciences, Manipal Academy of Higher Education Manipal Karnataka 576104 India
| | - Marimuthu Citartan
- Advanced Medical and Dental Institute, Universiti Sains Malaysia Kepala Batas Penang 13200 Malaysia
| | - Naresh Kumar Mani
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education Manipal Karnataka 576104 India
| |
Collapse
|
3
|
Huang KH, Yu CX, Lee CC, Tseng CC, Fu LM. Rapid Microfluidic Ion-Exchange Optode System for Point-of-Care Determination of Sodium Concentration in Serum. BIOSENSORS 2025; 15:104. [PMID: 39997006 PMCID: PMC11853684 DOI: 10.3390/bios15020104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2024] [Revised: 02/05/2025] [Accepted: 02/10/2025] [Indexed: 02/26/2025]
Abstract
A microfluidic system for detecting sodium ions (Na+) has been developed, incorporating a micro finger-pump chip and a micro-spectrometer platform to measure Na+ concentration in human serum. A small volume (10 μL) of serum sample is introduced into the microchip and reacted with a preloaded reagent mixture through a two-step finger-pump actuation process. The resulting purple complex is directed into the detection area of the chip and analyzed using the micro-spectrometer at wavelengths of 555 and 666 nm. The Na+ concentration is then inversely derived from the measured A555/A666 absorbance ratio using self-written software installed on a Raspberry Pi. The entire detection process is completed in just 3 min, offering a significant advantage in meeting clinical needs compared to the traditional reporting turnaround time of several hours in medical institutions. The experimental results indicate a linear relationship between the measured absorbance ratio and Na+ concentration within the range of 1-200 mM, with a correlation coefficient of R2 = 0.9989. Additionally, the detection results from 60 serum samples collected from chronic kidney disease (CKD) patients showed a strong agreement with those obtained using the conventional indirect ion-selective electrode (ISE) method, achieving a correlation coefficient of R2 = 0.9885 and an average recovery rate of 99.4%. In summary, the proposed system provides a practical, affordable, and rapid alternative to conventional Na+ detection methods, making it highly promising for point-of-care (POC) testing applications.
Collapse
Affiliation(s)
- Kuan-Hsun Huang
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan; (K.-H.H.); (C.-X.Y.)
| | - Cheng-Xue Yu
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan; (K.-H.H.); (C.-X.Y.)
| | - Chia-Chun Lee
- Division of Nephrology, Department of Internal Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 704, Taiwan; (C.-C.L.); (C.-C.T.)
- Institute of Clinical Medicine, College of Medicine, National Cheng Kung University, Tainan 704, Taiwan
| | - Chin-Chung Tseng
- Division of Nephrology, Department of Internal Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 704, Taiwan; (C.-C.L.); (C.-C.T.)
- Institute of Clinical Medicine, College of Medicine, National Cheng Kung University, Tainan 704, Taiwan
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan; (K.-H.H.); (C.-X.Y.)
| |
Collapse
|
4
|
Yang L, Zhai T, Wang J, Zheng H, Liu JM, Wang S. One simple and integrated nano-inspection platform for high-throughput detection of clenbuterol. Food Chem 2025; 464:141579. [PMID: 39406141 DOI: 10.1016/j.foodchem.2024.141579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 09/28/2024] [Accepted: 10/06/2024] [Indexed: 11/21/2024]
Abstract
To achieve high throughput detection of clenbuterol while reducing matrix interference, we developed a simple and integrated nano-inspection platform. Herein, based on the simplicity and convenience of paper chip, a multi-layer paper chip-chemiluminescence (CL) sensor was designed in the form of "48-well plate" type. The all-in-one paper chip-CL sensor has integrated the covalent organic frameworks (COFs) layer for sample matrix purification, high affinity nanobody layer for specific capture of target, and CL rapid response layer for the final determination. The signal readout was realized by the inhibitory effect of clenbuterol on the K3[Fe(CN)6] CL system. Detection of clenbuterol in pork meat was verified by measuring the CL intensity and satisfactory recoveries (85.9 %-97.3 %) were achieved. 48 samples could be simultaneously detected on one-chip in one-test, favoring the high-throughput detection. Especially, the work explored a new pathway for design of portable analytical instruments to achieve immediate on-site detection of hazards.
Collapse
Affiliation(s)
- Lu Yang
- Tianjin Key Laboratory of Food Science and Health, School of Medicine, Nankai University, Tianjin 300071, China
| | - Tong Zhai
- Tianjin Key Laboratory of Food Science and Health, School of Medicine, Nankai University, Tianjin 300071, China
| | - Jing Wang
- Tianjin Key Laboratory of Food Science and Health, School of Medicine, Nankai University, Tianjin 300071, China
| | - Hong Zheng
- Ogan Transplant Department, Tianjin First Central Hospital, School of Medicine, Nankai University, Tianjin 300071, China..
| | - Jing-Min Liu
- Tianjin Key Laboratory of Food Science and Health, School of Medicine, Nankai University, Tianjin 300071, China..
| | - Shuo Wang
- Tianjin Key Laboratory of Food Science and Health, School of Medicine, Nankai University, Tianjin 300071, China.; College of Food Science and Engineering, Tianjin University of Science and Technology, Tianjin 300457, China..
| |
Collapse
|
5
|
Tomac I, Adam V, Labuda J. Advanced chemically modified electrodes and platforms in food analysis and monitoring. Food Chem 2024; 460:140548. [PMID: 39096799 DOI: 10.1016/j.foodchem.2024.140548] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 06/22/2024] [Accepted: 07/18/2024] [Indexed: 08/05/2024]
Abstract
Electrochemical sensors and electroanalytical techniques become emerging as effective and low-cost tools for rapid assessment of special parameters of the food quality. Chemically modified electrodes are developed to change properties and behaviour, particularly sensitivity and selectivity, of conventional electroanalytical sensors. Within this comprehensive review, novel trends in chemical modifiers material structure, electrodes construction and flow analysis platforms are described and evaluated. Numerous recent application examples for the detection of food specific analytes are presented in a form of table to stimulate further development in both, the basic research and commercial field.
Collapse
Affiliation(s)
- Ivana Tomac
- Department of Applied Chemistry and Ecology, Faculty of Food Technology Osijek, J. J. Strossmayer University of Osijek, Franje Kuhača 18, 31000 Osijek, Croatia.
| | - Vojtech Adam
- Department of Chemistry and Biochemistry, Faculty of AgriSciences, Mendel University in Brno, Generála Píky 1999/5, 613 00 Brno, Czech Republic.
| | - Jan Labuda
- Institute of Analytical Chemistry, Faculty of Chemical and Food Technology, Slovak University of Technology in Bratislava, Radlinskeho 9, 812 37 Bratislava, Slovakia.
| |
Collapse
|
6
|
Tai S, Cao H, Barimah AO, Gao Y, Peng C, Xu J, Wang Z. Highly sensitive colorimetric and paper-based detection for sildenafil in functional food based on monodispersed spherical magnetic graphene composite nanozyme. Anal Chim Acta 2024; 1329:343260. [PMID: 39396317 DOI: 10.1016/j.aca.2024.343260] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 08/17/2024] [Accepted: 09/17/2024] [Indexed: 10/15/2024]
Abstract
BACKGROUND Sildenafil (SIL) is regarded as an illegal adulterant in functional foods. Some functional foods doped with SIL have posed significant concern about their safety risks. However, the facile colorimetric detection of SIL is rarely investigated. RESULTS Herein, we prepared a monodispersed spherical composite nanozyme (Fe3O4-NH2/GONRs), possessing excellent peroxidase-like (POD-like) and catalase-like (CAT-like) activities and strong superparamagnetic property. The enzyme-like activities of Fe3O4-NH2/GONRs can be selectively inhibited by SIL due to the synergistic effect of hydrogen bonds and π-π stacking between Fe3O4-NH2/GONRs and SIL. Leveraging this mechanism, a highly sensitive and selective colorimetric detection for SIL with a detection limit (LOD) of 0.26 ng/mL was developed. In addition, we prepared a three-dimensional paper-based analytical device (3D-PAD) for SIL colorimetric detection with naked-eyes and the semi-quantitative analysis with a LOD of 88 ng/mL. SIGNIFICANCE The proposed colorimetric and PAD detections demonstrated the advantages of low-cost, highly sensitive and selective, thus have promise application potential in the rapid detection of adulterated functional foods.
Collapse
Affiliation(s)
- Shengmei Tai
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China
| | - Hui Cao
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China
| | - Alberta Osei Barimah
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China
| | - Yanan Gao
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China
| | - Chifang Peng
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Life Science and Health Engineering, Jiangnan University, Wuxi, 214122, China; International Joint Laboratory On Food Safety, Jiangnan University, Wuxi, 214122, China.
| | - Jianguo Xu
- Key Laboratory of Molecular Recognition and Sensing, College of Biological, Chemical Sciences and Engineering, Jiaxing University, Jiaxing, 314001, China
| | - Zhouping Wang
- State Key Laboratory of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Food Science and Technology, Jiangnan University, Wuxi, 214122, China; School of Life Science and Health Engineering, Jiangnan University, Wuxi, 214122, China; International Joint Laboratory On Food Safety, Jiangnan University, Wuxi, 214122, China
| |
Collapse
|
7
|
Gautam N, Verma R, Muduli PR, Kar S, Sarkar A. Quantification of creatinine in whole blood by a paper-based device using an RGB sensor. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:7546-7556. [PMID: 39370960 DOI: 10.1039/d4ay01476f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/08/2024]
Abstract
Creatinine, an important biomarker for renal functions, is often conventionally estimated using the gold standard Jaffe reaction from blood, which involves the usage of a spectrophotometric measurement, thus restricting its utilization scope in point-of-care settings. Here, we report the development of a method for the single-step quantification of creatinine from whole blood using a paper-based microfluidic device. Our platform uses Whatman filter paper integrated with an LF1 membrane. The on-chip separation of blood plasma is achieved through the LF1 membrane, while the Whatman component of the device contains the embedded reagents for the Jaffe reaction. The combination of two different grades of paper enables a single-step quantification of creatinine as the separated blood plasma traverses to the reaction zone through capillary imbibition. Colorimetric readouts were quantified using an RGB sensor instead of a smartphone, which is highly platform dependent and incurs a relatively higher cost compared to the other components in typical point-of care (POC) devices. Our sensor was integrated within a 3D box, thereby making the detection virtually instrument free and perfectly suited for POC settings. The limit of detection (LOD) of our device was 0.219 mg dL-1, which falls within the lower range of physiological values. The coefficient of determination (R2) for the linearity and median accuracy were 0.978 and 94.047%, respectively. The relative standard deviation (RSD) for precision measurements remained below 5% for the developed protocol. Furthermore, we validated the performance of our device with 35 clinical samples in laboratory settings against the gold standard measurements. Our Bland-Altman plot as well as t-test and chi-square test results clearly confirmed the validity of our device within a 95% confidence interval.
Collapse
Affiliation(s)
- Neha Gautam
- Department of Mechanical Engineering, Indian Institute of Technology (BHU), Varanasi-221005, India.
| | - Ranjana Verma
- Department of Mechanical Engineering, Indian Institute of Technology (BHU), Varanasi-221005, India.
| | - Priya Ranjan Muduli
- Department of Electronics Engineering, Indian Institute of Technology (BHU), Varanasi-221005, India
| | - Shantimoy Kar
- Department of Medical Devices, National Institute of Pharmaceutical Education and Research, Hyderabad-500037, India.
- Department of Biotechnology, GITAM School of Technology, GITAM (Deemed to be University) Visakhapatnam, India 530045
| | - Arnab Sarkar
- Department of Mechanical Engineering, Indian Institute of Technology (BHU), Varanasi-221005, India.
| |
Collapse
|
8
|
He HJ, da Silva Ferreira MV, Wu Q, Karami H, Kamruzzaman M. Portable and miniature sensors in supply chain for food authentication: a review. Crit Rev Food Sci Nutr 2024:1-21. [PMID: 39066550 DOI: 10.1080/10408398.2024.2380837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/28/2024]
Abstract
Food fraud, a pervasive issue in the global food industry, poses significant challenges to consumer health, trust, and economic stability, costing an estimated $10-15 billion annually. Therefore, there is a rising demand for developing portable and miniature sensors that facilitate food authentication throughout the supply chain. This review explores the recent advancements and applications of portable and miniature sensors, including portable/miniature near-infrared (NIR) spectroscopy, e-nose and colorimetric sensors based on nanozyme for food authentication within the supply chain. After briefly presenting the architecture and mechanism, this review discusses the application of these portable and miniature sensors in food authentication, addressing the challenges and opportunities in integrating and deploying these sensors to ensure authenticity. This review reveals the enhanced utility of portable/miniature NIR spectroscopy, e-nose, and nanozyme-based colorimetric sensors in ensuring food authenticity and enabling informed decision-making throughout the food supply chain.
Collapse
Affiliation(s)
- Hong-Ju He
- School of Food Science, Henan Institute of Science and Technology, Xinxiang, China
| | | | - Qianyi Wu
- Department of Agriculture and Biological Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Hamed Karami
- Department of Petroleum Engineering, Collage of Engineering, Knowledge University, Erbil, Iraq
| | - Mohammed Kamruzzaman
- School of Food Science, Henan Institute of Science and Technology, Xinxiang, China
| |
Collapse
|
9
|
Ang B, Jirapanjawat T, Tay KP, Ashtiani D, Greening C, Tuck KL, Neild A, Cadarso VJ. Rapid Concentration and Detection of Bacteria in Milk Using a Microfluidic Surface Acoustic Wave Activated Nanosieve. ACS Sens 2024; 9:3105-3114. [PMID: 38753893 DOI: 10.1021/acssensors.4c00291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/18/2024]
Abstract
Rapid detection of microbes is a key feature for monitoring food quality. Unfortunately, current detection systems rely on labor-intensive and time-consuming lab-based processes that are not suitable for point-of-interest applications and typically require several days before results are available. Here, we demonstrate a microfluidic system capable of rapidly concentrating, fluorescent staining, and detecting bacteria in unprocessed complex biological media such as milk. This concentration is done using a surface acoustic wave-driven microfluidic device which operates based on the Bjerknes force, a force generated on one particle by another in its close proximity. We exploit this effect by exciting a tightly packed bed of 50 μm polystyrene microparticles temporarily with surface acoustic waves within a microfluidic device to capture and release bacterial cells on demand. The bacterial cells are fluorescently stained during capture and then detected using fluorescence microscopy upon release. This device offers a high capturing efficiency (>80%) and a 34 Colony Forming Units (CFU)/mL limit of detection, which is 1 order of magnitude below that of plate counting at 30 CFU per standard 100 μL plate (or 300 CFU/mL). This can be attained in just 1 h of processing at 10 μL/min. With this system, we demonstrate that bacterial detection from extremely low concentration samples down to the order of ∼10 CFU/mL is possible without requiring any additional external pre- or postprocessing.
Collapse
Affiliation(s)
- Bryan Ang
- Department of Mechanical and Aerospace Engineering, Monash University, Clayton 3168, Victoria, Australia
- Centre to Impact Antimicrobial Resistance, Monash University, Clayton 3168, Victoria, Australia
| | - Thanavit Jirapanjawat
- Department of Microbiology, Biomedicine Discovery Institute, Monash University, Clayton 3168, Victoria, Australia
| | - Khai Ping Tay
- Department of Mechanical and Aerospace Engineering, Monash University, Clayton 3168, Victoria, Australia
| | | | - Chris Greening
- Centre to Impact Antimicrobial Resistance, Monash University, Clayton 3168, Victoria, Australia
- Department of Microbiology, Biomedicine Discovery Institute, Monash University, Clayton 3168, Victoria, Australia
| | - Kellie L Tuck
- School of Chemistry, Monash University, Clayton 3800, Victoria, Australia
| | - Adrian Neild
- Department of Mechanical and Aerospace Engineering, Monash University, Clayton 3168, Victoria, Australia
| | - Victor J Cadarso
- Department of Mechanical and Aerospace Engineering, Monash University, Clayton 3168, Victoria, Australia
- Centre to Impact Antimicrobial Resistance, Monash University, Clayton 3168, Victoria, Australia
| |
Collapse
|
10
|
Gong L, Lin Y. Microfluidics in smart food safety. ADVANCES IN FOOD AND NUTRITION RESEARCH 2024; 111:305-354. [PMID: 39103216 DOI: 10.1016/bs.afnr.2024.06.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/07/2024]
Abstract
The evolution of food safety practices is crucial in addressing the challenges posed by a growing global population and increasingly complex food supply chains. Traditional methods are often labor-intensive, time-consuming, and susceptible to human error. This chapter explores the transformative potential of integrating microfluidics into smart food safety protocols. Microfluidics, involving the manipulation of small fluid volumes within microscale channels, offers a sophisticated platform for developing miniaturized devices capable of complex tasks. Combined with sensors, actuators, big data analytics, artificial intelligence, and the Internet of Things, smart microfluidic systems enable real-time data acquisition, analysis, and decision-making. These systems enhance control, automation, and adaptability, making them ideal for detecting contaminants, pathogens, and chemical residues in food products. The chapter covers the fundamentals of microfluidics, its integration with smart technologies, and its applications in food safety, addressing the challenges and future directions in this field.
Collapse
Affiliation(s)
- Liyuan Gong
- Department of Mechanical, Industrial and Systems Engineering, University of Rhode Island, Kingston, RI, United States
| | - Yang Lin
- Department of Mechanical, Industrial and Systems Engineering, University of Rhode Island, Kingston, RI, United States.
| |
Collapse
|
11
|
Chen SJ, Lu SY, Tseng CC, Huang KH, Chen TL, Fu LM. Rapid Microfluidic Immuno-Biosensor Detection System for the Point-of-Care Determination of High-Sensitivity Urinary C-Reactive Protein. BIOSENSORS 2024; 14:283. [PMID: 38920587 PMCID: PMC11201708 DOI: 10.3390/bios14060283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 05/20/2024] [Accepted: 05/28/2024] [Indexed: 06/27/2024]
Abstract
A microfluidic immuno-biosensor detection system consisting of a microfluidic spectrum chip and a micro-spectrometer detection device is presented for the rapid point-of-care (POC) detection and quantification of high-sensitivity C-reactive protein (hs-CRP) in urine. The detection process utilizes a highly specific enzyme-linked immunosorbent assay (ELISA) method, in which capture antibodies and detection antibodies are pre-deposited on the substrate of the microchip and used to form an immune complex with the target antigen. Horseradish peroxidase (HRP) is added as a marker enzyme, followed by a colorimetric reaction using 3,3',5,5'-tetramethylbenzidine (TMB). The absorbance values (a.u.) of the colorimetric reaction compounds are measured using a micro-spectrometer device and used to measure the corresponding hs-CRP concentration according to the pre-established calibration curve. It is shown that the hs-CRP concentration can be determined within 50 min. In addition, the system achieves recovery rates of 93.8-106.2% in blind water samples and 94.5-104.6% in artificial urine. The results showed that the CRP detection results of 41 urine samples from patients with chronic kidney disease (CKD) were highly consistent with the conventional homogeneous particle-enhanced turbidimetric immunoassay (PETIA) method's detection results (R2 = 0.9910). The experimental results showed its applicability in the detection of CRP in both urine and serum. Overall, the results indicate that the current microfluidic ELISA detection system provides an accurate and reliable method for monitoring the hs-CRP concentration in point-of-care applications.
Collapse
Affiliation(s)
- Szu-Jui Chen
- Department of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan; (S.-J.C.); (S.-Y.L.); (K.-H.H.); (T.-L.C.)
| | - Song-Yu Lu
- Department of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan; (S.-J.C.); (S.-Y.L.); (K.-H.H.); (T.-L.C.)
| | - Chin-Chung Tseng
- Division of Nephrology, Department of Internal Medicine, National Cheng Kung University Hospital, Tainan 70101, Taiwan;
- College of Medicine, National Cheng Kung University, Tainan 70101, Taiwan
| | - Kuan-Hsun Huang
- Department of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan; (S.-J.C.); (S.-Y.L.); (K.-H.H.); (T.-L.C.)
| | - To-Lin Chen
- Department of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan; (S.-J.C.); (S.-Y.L.); (K.-H.H.); (T.-L.C.)
| | - Lung-Ming Fu
- Department of Engineering Science, National Cheng Kung University, Tainan 70101, Taiwan; (S.-J.C.); (S.-Y.L.); (K.-H.H.); (T.-L.C.)
| |
Collapse
|
12
|
Lee S, Kim H, Lim H, Nam Y, Lee S, Kim H. Nanostructured Substrate-Mediated Bubble Degassing in Microfluidic Systems. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:8630-8635. [PMID: 38587497 DOI: 10.1021/acs.langmuir.4c00359] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/09/2024]
Abstract
Microfluidic platforms have been widely used in a variety of fields owing to their numerous advantages. The prevention and prompt removal of air bubbles from microchannels are important to ensuring the optimal functioning of microfluidic devices. The entrapment of bubbles in the microchannels can result in flow instability and device performance disruption. Active and passive methods are the primary categories of degassing technologies. Active methods rely on external equipment, and passive methods operate autonomously without any external sources. This study proposed a passive degassing method that employs a nanoscale surface morphology integrated into the substrate of a microfluidic device. Nanostructures exhibit a microchannel geometry and are fabricated based on surface micromachining technology using silver ink and chemical etching. Consequently, the gas permeability is enhanced, resulting in effective degassing through the nanostructure. The performance of this degassing method was characterized under varying substrate permeabilities and input pressure conditions, and it was found that increased permeability facilitates the degassing performance. Furthermore, the applicability of our method was demonstrated by using a serpentine channel design prone to gas entrapment, particularly in the corner regions. The nanostructured substrate exhibited significantly improved degassing performance under the given pressure conditions in comparison to the glass substrate.
Collapse
Affiliation(s)
- Sanghyun Lee
- Division of Mechanical, Automotive, Robot Component Engineering, Dongeui University, Busan 47340, Republic of Korea
| | - Hyewon Kim
- School of Mechanical and Aerospace Engineering, Gyeongsang National University, Jinju 52828, Republic of Korea
| | - Hyewon Lim
- School of Mechanical and Aerospace Engineering, Gyeongsang National University, Jinju 52828, Republic of Korea
| | - Yejin Nam
- Division of Mechanical, Automotive, Robot Component Engineering, Dongeui University, Busan 47340, Republic of Korea
| | - Sangmin Lee
- Division of Mechanical, Automotive, Robot Component Engineering, Dongeui University, Busan 47340, Republic of Korea
| | - Hyungmo Kim
- School of Mechanical and Aerospace Engineering, Gyeongsang National University, Jinju 52828, Republic of Korea
| |
Collapse
|
13
|
Hilda L, Mutlaq MS, Waleed I, Althomali RH, Mahdi MH, Abdullaev SS, Singh R, Nasser HA, Mustafa YF, Alawadi AHR. Genosensor on-chip paper for point of care detection: A review of biomedical analysis and food safety application. Talanta 2024; 268:125274. [PMID: 37839324 DOI: 10.1016/j.talanta.2023.125274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2023] [Revised: 10/01/2023] [Accepted: 10/03/2023] [Indexed: 10/17/2023]
Abstract
Over the last decade, paper-based biosensing has attracted considerable attention in numerous fields due to several advantages of them. To elaborate, using paper as a substrate of sensing approaches can be considered an affordable sensing approach owing to low cost of paper, and alongside that, the ability to operate without requiring external equipment. In many cases, cost-effective fabrication techniques such as screen printed and drop casting can be supposed as other benefits of these platforms. Despite the portability and affordability of paper-based assay, two important limitations including sensitivity and selectivity can decrease the application of these sensing approaches. Initially, decoration of paper substrate with nanomaterials (NMs) can improve the properties of paper due to high surface area and conductivity of them. Secondly, the presence of bioreceptors can provide a selective detection platform. Among different bioreceptors, deoxyribonucleic acid (DNA) and ribonucleic acid (RNA) can play a significant role. From this perspective, paper-based biosensors can be used for the detection of various gens which related to biomedical or food safety. In this review, we attempted to summarize recent trends and applications of paper-based genosensor, along with critical arguments in terms of NMs role in signal amplification. Furthermore, the lack of paper-based genosensors in field the of biomedical and food safety will be discussed in the following.
Collapse
Affiliation(s)
- Lelya Hilda
- Department of Chemistry, Universitas Islam Negeri Syekh Ali Hasan Ahmad Addary Padangsidimpuan, Padangsidimpuan, Indonesia.
| | - Maysam Salih Mutlaq
- Department of Radiology & Sonar Techniques, AlNoor University College, Nineveh, Iraq
| | | | - Raed H Althomali
- Department of Chemistry, Prince Sattam Bin Abdulaziz University, College of Arts and Science, Wadi Al-Dawasir, 11991, Saudi Arabia
| | | | - Sherzod Shukhratovich Abdullaev
- Faculty of Chemical Engineering, New Uzbekistan University, Tashkent, Uzbekistan; Department of Chemical Engineering, Central Asian University, Tashkent, Uzbekistan; Scientific and Innovation Department, Tashkent State Pedagogical University named after Nizami, Tashkent, Uzbekistan
| | - Rajesh Singh
- Department of Electronics & Communication Engineering, Uttaranchal Institute of Technology, Uttaranchal University, Dehradun, 248007, India
| | | | - Yasser Fakri Mustafa
- Department of Pharmaceutical Chemistry, College of Pharmacy, University of Mosul, Mosul, 41001, Iraq
| | - Ahmed H R Alawadi
- Building and Construction Technical Engineering Department, College of Technical Engineering, The Islamic university, Najaf, Iraq
| |
Collapse
|
14
|
Yuan M, Li C, Zheng Y, Cao H, Ye T, Wu X, Hao L, Yin F, Yu J, Xu F. A portable multi-channel fluorescent paper-based microfluidic chip based on smartphone imaging for simultaneous detection of four heavy metals. Talanta 2024; 266:125112. [PMID: 37659229 DOI: 10.1016/j.talanta.2023.125112] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Revised: 08/10/2023] [Accepted: 08/22/2023] [Indexed: 09/04/2023]
Abstract
Due to the excessive contamination of heavy metals pollution, it is very urgent and necessary to develop a real-time detection method for the heavy metals in food. As a target sensing device, a paper-based microfluidic device (μPAD) has the advantages of simplicity, low-cost, and portability. In this study, a self-driven microfluidic paper-based chip was first developed for the simultaneous detection of four targets. The channels on the microfluidic chip were prepared by using wax printing and automatic screen printing on the filter paper, where liquid flowed by capillary force without pump assistance. Based on the specific binding ability of aptamers to heavy metals, a "turn-on" fluorescence aptasensor for the simultaneous detection of four heavy metal ions was developed on the proposed multi-channel device via smartphone imaging. The obtained fluorescence images were digitized into RGB color values by Image J software, and an M-mode was established to realize the quantitative detection of heavy metal ions. Under optimal conditions, the limits of detection for lead(II), mercury(II), cadmium(II), and arsenic(III) were 4.20 nM, 1.70 nM, 2.04 nM, and 1.65 nM, respectively. Furthermore, the aptasensor was successfully applied to the quantitative detection of four heavy metal ions in apple and lettuce samples with recovery rates of 84.0%-104.1%.
Collapse
Affiliation(s)
- Min Yuan
- Shanghai Engineering Research Center of Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai, China
| | - Chen Li
- Shanghai Engineering Research Center of Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai, China; Qingdao Institute of Technology, Shandong, China
| | - Yuzhu Zheng
- Shanghai Engineering Research Center of Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai, China
| | - Hui Cao
- Shanghai Engineering Research Center of Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai, China
| | - Tai Ye
- Shanghai Engineering Research Center of Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai, China
| | - Xiuxiu Wu
- Shanghai Engineering Research Center of Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai, China
| | - Liling Hao
- Shanghai Engineering Research Center of Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai, China
| | - Fengqin Yin
- Shanghai Engineering Research Center of Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai, China
| | - Jinsong Yu
- Shanghai Engineering Research Center of Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai, China
| | - Fei Xu
- Shanghai Engineering Research Center of Food Rapid Detection, University of Shanghai for Science and Technology, Shanghai, China.
| |
Collapse
|
15
|
Seddaoui N, Colozza N, Gullo L, Arduini F. Paper as smart support for bioreceptor immobilization in electrochemical paper-based devices. Int J Biol Macromol 2023; 253:127409. [PMID: 37848114 DOI: 10.1016/j.ijbiomac.2023.127409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 10/08/2023] [Accepted: 10/10/2023] [Indexed: 10/19/2023]
Abstract
The use of paper as a smart support in the field of electrochemical sensors has been largely improved over the last 15 years, driven by its outstanding features such as foldability and porosity, which enable the design of reagent and equipment-free multi-analysis devices. Furthermore, the easy surface engineering of paper has been used to immobilize different bioreceptors, through physical adsorption, covalent bonding, and electrochemical polymerization, boosting the fine customization of the analytical performances of paper-based biosensors. In this review, we focused on the strategies to engineer the surface of the paper for the immobilization of (bio)recognition elements (eg., enzymes, antibodies, DNA, molecularly imprinted polymers) with the overriding goal to develop accurate and reliable paper-based electrochemical biosensors. Furthermore, we highlighted how to take advantage of paper for designing smart configurations by integrating different analytical processes in an eco-designed analytical tool, starting from the immobilization of the (bio)receptor and the reagents, through a designed sample flow along the device, until the analyte detection.
Collapse
Affiliation(s)
- Narjiss Seddaoui
- Department of Chemical Science and Technologies, University of Rome "Tor Vergata", Via della Ricerca Scientifica, 00133 Rome, Italy
| | - Noemi Colozza
- Department of Chemical Science and Technologies, University of Rome "Tor Vergata", Via della Ricerca Scientifica, 00133 Rome, Italy; SENSE4MED S.R.L, Via Bitonto 139, 00133 Rome, Italy
| | - Ludovica Gullo
- Department of Chemical Science and Technologies, University of Rome "Tor Vergata", Via della Ricerca Scientifica, 00133 Rome, Italy
| | - Fabiana Arduini
- Department of Chemical Science and Technologies, University of Rome "Tor Vergata", Via della Ricerca Scientifica, 00133 Rome, Italy; SENSE4MED S.R.L, Via Bitonto 139, 00133 Rome, Italy.
| |
Collapse
|
16
|
Uttam I, Sudarsan S, Ray R, Chinnappan R, Yaqinuddin A, Al-Kattan K, Mani NK. A Hypothetical Approach to Concentrate Microorganisms from Human Urine Samples Using Paper-Based Adsorbents for Point-of-Care Molecular Assays. Life (Basel) 2023; 14:38. [PMID: 38255653 PMCID: PMC10820215 DOI: 10.3390/life14010038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 12/20/2023] [Accepted: 12/21/2023] [Indexed: 01/24/2024] Open
Abstract
This hypothesis demonstrates that the efficiency of loop-mediated isothermal amplification (LAMP) for nucleic acid detection can be positively influenced by the preconcentration of microbial cells onto hydrophobic paper surfaces. The mechanism of this model is based on the high affinity of microbes towards hydrophobic surfaces. Extensive studies have demonstrated that hydrophobic surfaces exhibit enhanced bacterial and fungal adhesion. By exploiting this inherent affinity of hydrophobic paper substrates, the preconcentration approach enables the adherence of a greater number of target cells, resulting in a higher concentration of target templates for amplification directly from urine samples. In contrast to conventional methods, which often involve complex procedures, this approach offers a simpler, cost-effective, and user-friendly alternative. Moreover, the integration of cell adhesion, LAMP amplification, and signal readout within paper origami-based devices can provide a portable, robust, and highly efficient platform for rapid nucleic acid detection. This innovative hypothesis holds significant potential for point-of-care (POC) diagnostics and field surveillance applications. Further research and development in this field will advance the implementation of this technology, contributing to improved healthcare systems and public health outcomes.
Collapse
Affiliation(s)
- Isha Uttam
- Microfluidics, Sensors and Diagnostics (µSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, Karnataka, India; (I.U.); (S.S.)
| | - Sujesh Sudarsan
- Microfluidics, Sensors and Diagnostics (µSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, Karnataka, India; (I.U.); (S.S.)
| | - Rohitraj Ray
- Department of BioSystems Science and Engineering (BSSE), Indian Institute of Science, CV Raman Rd, Bangalore 560012, Karnataka, India;
| | - Raja Chinnappan
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (A.Y.); (K.A.-K.)
- Tissue/Organ Bioengineering & BioMEMS Lab, Organ Transplant Centre of Excellence, Transplant Research & Innovation Department, King Faisal Specialist Hospital and Research Centre, Riyadh 11211, Saudi Arabia
| | - Ahmed Yaqinuddin
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (A.Y.); (K.A.-K.)
| | - Khaled Al-Kattan
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia; (A.Y.); (K.A.-K.)
| | - Naresh Kumar Mani
- Microfluidics, Sensors and Diagnostics (µSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal 576104, Karnataka, India; (I.U.); (S.S.)
| |
Collapse
|
17
|
Ray R, Rakesh A, Singh S, Madhyastha H, Mani NK. Hair and Nail-On-Chip for Bioinspired Microfluidic Device Fabrication and Biomarker Detection. Crit Rev Anal Chem 2023:1-27. [PMID: 38133962 DOI: 10.1080/10408347.2023.2291825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2023]
Abstract
The advent of biosensors has tremendously increased our potential of identifying and solving important problems in various domains, ranging from food safety and environmental analysis, to healthcare and medicine. However, one of the most prominent drawbacks of these technologies, especially in the biomedical field, is to employ conventional samples, such as blood, urine, tissue extracts and other body fluids for analysis, which suffer from the drawbacks of invasiveness, discomfort, and high costs encountered in transportation and storage, thereby hindering these products to be applied for point-of-care testing that has garnered substantial attention in recent years. Therefore, through this review, we emphasize for the first time, the applications of switching over to noninvasive sampling techniques involving hair and nails that not only circumvent most of the aforementioned limitations, but also serve as interesting alternatives in understanding the human physiology involving minimal costs, equipment and human interference when combined with rapidly advancing technologies, such as microfluidics and organ-on-a-chip to achieve miniaturization on an unprecedented scale. The coalescence between these two fields has not only led to the fabrication of novel microdevices involving hair and nails, but also function as robust biosensors for the detection of biomarkers, chemicals, metabolites and nucleic acids through noninvasive sampling. Finally, we have also elucidated a plethora of futuristic innovations that could be incorporated in such devices, such as expanding their applications in nail and hair-based drug delivery, their potential in serving as next-generation wearable sensors and integrating these devices with machine-learning for enhanced automation and decentralization.
Collapse
Affiliation(s)
- Rohitraj Ray
- Department of Bioengineering (BE), Indian Institute of Science Bangalore, Bengaluru, Karnataka, India
| | - Amith Rakesh
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576 104, India
| | - Sheetal Singh
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576 104, India
| | - Harishkumar Madhyastha
- Department of Cardiovascular Physiology, Faculty of Medicine, University of Miyazaki, Miyazaki, Japan
| | - Naresh Kumar Mani
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka 576 104, India
| |
Collapse
|
18
|
Bouza M, Ahlmann N, García-Reyes JF, Franzke J. Solvent-Assisted Laser Desorption Flexible Microtube Plasma Mass Spectrometry for Direct Analysis of Dried Samples on Paper. Anal Chem 2023; 95:18370-18378. [PMID: 37902451 PMCID: PMC10733904 DOI: 10.1021/acs.analchem.3c03009] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 09/11/2023] [Accepted: 10/20/2023] [Indexed: 10/31/2023]
Abstract
The present study investigated the potential for solvent-assisted laser desorption coupled with flexible microtube plasma ionization mass spectrometry (SALD-FμTP-MS) as a rapid analytical technique for direct analysis of surface-deposited samples. Paper was used as the demonstrative substrate, and an infrared hand-held laser was employed for sample desorption, aiming to explore cost-effective sampling and analysis methods. SALD-FμTP-MS offers several advantages, particularly for biofluid analysis, including affordability, the ability to analyze low sample volumes (<10 μL), expanded chemical coverage, sample and substrate stability, and in situ analysis and high throughput potential. The optimization process involved exploring the use of viscous solvents with high boiling points as liquid matrices. This approach aimed to enhance desorption and ionization efficiencies. Ethylene glycol (EG) was identified as a suitable solvent, which not only improved sensitivity but also ensured substrate stability during analysis. Furthermore, the addition of cosolvents such as acetonitrile/water (1:1) and ethyl acetate further enhanced sensitivity and reproducibility for a standard solution containing amphetamine, imazalil, and cholesterol. Optimized conditions for reproducible and sensitive analysis were determined as 1000 ms of laser exposure time using a 1 μL solvent mixture of 60% EG and 40% acetonitrile (ACN)/water (1:1). A mixture of 60% EG and 40% ACN/water (1:1) resulted in signal enhancements and relative standard deviations of 12, 20, and 13% for the evaluated standards, respectively. The applicability of SALD-FμTP-MS was further evaluated by successfully analyzing food, water, and biological samples, highlighting the potential of SALD-FμTP-MS analysis, particularly for thermolabile and polarity diverse compounds.
Collapse
Affiliation(s)
- Marcos Bouza
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071 Jaén, Spain
| | - Norman Ahlmann
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| | - Juan F. García-Reyes
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071 Jaén, Spain
| | - Joachim Franzke
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| |
Collapse
|
19
|
Zhu T, Chen J, Zeng S, Chen J, Qi C. Highly Stable Fluorescent-Traffic-Light Sensor for Point-of-Care Detection of Tetracycline. ACS Sens 2023; 8:4272-4280. [PMID: 37862265 DOI: 10.1021/acssensors.3c01620] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2023]
Abstract
Fluorescent point-of-care (POC) sensors have found great utility in fields like clinical diagnosis, food testing, and environmental monitoring. Herein, we developed a highly stable POC sensor that enabled the visual detection of tetracycline (TC) in a distinct fluorescent-traffic-light manner. In the sensor, a composite material of copper nanoclusters and metal-organic framework (CuNCs@MOF-5) prepared with a facile one-pot synthetic strategy was employed as the core element for target recognition and signal transduction. As evidenced by experiments, the as-prepared CuNCs@MOF-5 exhibited significantly improved fluorescence properties in terms of emission enhancement (about 28-fold) and stability improvement (over 110 days) compared to the CuNCs without confining and protection by MOF-5. More importantly, it was found that TC could uniquely interact with Zn(II) to trigger the disassembly of CuNCs@MOF-5, resulting in green fluorescence emission from the TC-Zn(II) complex and red fluorescence weakening of CuNCs. On the basis of this finding, a simple and stable sensor was proposed for POC detection of TC, which demonstrated high sensitivity, selectivity, and reproducibility. In addition to homogeneous visual detection in a 96-well plate, a CuNCs@MOF-5-contained agarose gel array was easily fabricated to achieve direct detection of TC in milk without any pretreatment, thanks to the size-sieving effect of the gel. Moreover, a test paper array was also put forward for low-cost TC detection, which indicates the extensibility and practicability of this sensing strategy.
Collapse
Affiliation(s)
- Ting Zhu
- Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering of Hubei Normal University, Huangshi, Hubei 435002, China
| | - Jinyang Chen
- Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering of Hubei Normal University, Huangshi, Hubei 435002, China
| | - Shasha Zeng
- Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering of Hubei Normal University, Huangshi, Hubei 435002, China
| | - Jintao Chen
- Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering of Hubei Normal University, Huangshi, Hubei 435002, China
| | - Chunjiao Qi
- Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering of Hubei Normal University, Huangshi, Hubei 435002, China
| |
Collapse
|
20
|
Sudarsan S, Shetty P, Chinnappan R, Mani NK. Tuning Hydrophobicity of Paper Substrates for Effective Colorimetric detection of Glucose and Nucleic acids. Anal Bioanal Chem 2023; 415:6449-6460. [PMID: 37665340 PMCID: PMC10567893 DOI: 10.1007/s00216-023-04921-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 08/22/2023] [Accepted: 08/23/2023] [Indexed: 09/05/2023]
Abstract
This study investigated the colorimetric response of standard glucose, serum glucose, and nucleic acid assays on various paper surfaces with different wettability, including hydrophilic, hydrophobic, and nearly superhydrophobic surfaces. Water contact angles (WCA) formed by water droplets on each surface were measured using ImageJ software. The hydrophilic surface showed no contact angle, while the hydrophobic and nearly superhydrophobic surfaces exhibited contact angles of 115.667° and 133.933°, respectively. The colorimetric sensitivity of the standard glucose assay was analyzed on these surfaces, revealing enhanced sensitivity on the nearly superhydrophobic surface due to the high molecular crowding effect owing to its non-wetting behavior and eventually confined reaction product at the sample loading zone. The hydrophobic nature of the surface restricts the spreading and diffusion of the reaction product, leading to a controlled and localized concentration of the assay product leading to moderate colorimetric intensity. On the other hand, the hydrophilic surface showed the least enhancement in colorimetric sensitivity; this is attributed to the high wettability of the hydrophilic surface causing the reaction product to spread extensively, resulting in a larger area of dispersion and consequently a lower colorimetric intensity. The measured limit of detection (LOD) for nucleic acid on nearly superhydrophobic surfaces was found to be 16.15 ng/µL, which was almost four-fold lower than on hydrophilic surfaces (60.08 ng/µL). Additionally, the LODs of standard glucose and clinical serum samples were two-fold lower on nearly superhydrophobic surfaces compared to hydrophilic surfaces. Our findings clearly highlight the promising potential of utilizing superhydrophobic surfaces to significantly enhance colorimetric sensitivity in paper-based diagnostic applications. This innovative approach holds promise for advancing point-of-care diagnostics and improving disease detection in resource-limited settings.
Collapse
Affiliation(s)
- Sujesh Sudarsan
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Prashil Shetty
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India
| | - Raja Chinnappan
- College of Medicine, Alfaisal University, 11533, Riyadh, Saudi Arabia
| | - Naresh Kumar Mani
- Microfluidics, Sensors and Diagnostics (μSenD) Laboratory, Centre for Microfluidics, Biomarkers, Photoceutics and Sensors (μBioPS), Department of Biotechnology, Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
| |
Collapse
|
21
|
Bhardwaj SK, Deep A, Bhardwaj N, Wangoo N. Recent advancements in nanomaterial based optical detection of food additives: a review. Analyst 2023; 148:5322-5339. [PMID: 37750046 DOI: 10.1039/d3an01317k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/27/2023]
Abstract
Food additives have become a critical component in the food industry. They are employed as preservatives to decelerate the negative effects of environmental and microbial factors on food quality. Currently, food additives are used for a variety of purposes, including colorants, flavor enhancers, nutritional supplements, etc., owing to improvements in the food industry. Since the usage of food additives has increased dramatically, the efficient monitoring of their acceptable levels in food products is quite necessary to mitigate the problems associated with their inappropriate use. The traditional methods used for detecting food additives are generally based on standard spectroscopic and chromatographic techniques. However, these analytical techniques are limited by their high instrumentation cost and time-consuming procedures. The emerging field of nanotechnology has enabled the development of highly sensitive and specific sensors to analyze food additives in a rapid manner. The current article emphasizes the need to detect various food additives owing to their potential negative effects on humans, animals, and the environment. In this article, the role of nanomaterials in the optical sensing of food additives has been discussed owing to their high accuracy, ease-of-use, and excellent sensitivity. The applications of nanosensors for the detection of various food additives have been elaborated with examples. The current article will assist policymakers in developing new rules and regulations to mitigate the adverse effects of toxic food additives on humans and the environment. In addition, the prospects of nanosensors for the optical detection of food additives at a commercial scale have been discussed to combat their irrational use in the food industry.
Collapse
Affiliation(s)
- Sanjeev K Bhardwaj
- Department of Applied Sciences, University Institute of Engineering Technology (UIET), Panjab University, Chandigarh, India.
| | - Akash Deep
- Energy and Environment unit, Institute of Nanoscience and Technology, Mohali, India.
| | - Neha Bhardwaj
- Energy and Environment unit, Institute of Nanoscience and Technology, Mohali, India.
| | - Nishima Wangoo
- Department of Applied Sciences, University Institute of Engineering Technology (UIET), Panjab University, Chandigarh, India.
| |
Collapse
|
22
|
Musile G, Grazioli C, Fornasaro S, Dossi N, De Palo EF, Tagliaro F, Bortolotti F. Application of Paper-Based Microfluidic Analytical Devices (µPAD) in Forensic and Clinical Toxicology: A Review. BIOSENSORS 2023; 13:743. [PMID: 37504142 PMCID: PMC10377625 DOI: 10.3390/bios13070743] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 06/14/2023] [Accepted: 06/23/2023] [Indexed: 07/29/2023]
Abstract
The need for providing rapid and, possibly, on-the-spot analytical results in the case of intoxication has prompted researchers to develop rapid, sensitive, and cost-effective methods and analytical devices suitable for use in nonspecialized laboratories and at the point of need (PON). In recent years, the technology of paper-based microfluidic analytical devices (μPADs) has undergone rapid development and now provides a feasible, low-cost alternative to traditional rapid tests for detecting harmful compounds. In fact, µPADs have been developed to detect toxic molecules (arsenic, cyanide, ethanol, and nitrite), drugs, and drugs of abuse (benzodiazepines, cathinones, cocaine, fentanyl, ketamine, MDMA, morphine, synthetic cannabinoids, tetrahydrocannabinol, and xylazine), and also psychoactive substances used for drug-facilitated crimes (flunitrazepam, gamma-hydroxybutyric acid (GHB), ketamine, metamizole, midazolam, and scopolamine). The present report critically evaluates the recent developments in paper-based devices, particularly in detection methods, and how these new analytical tools have been tested in forensic and clinical toxicology, also including future perspectives on their application, such as multisensing paper-based devices, microfluidic paper-based separation, and wearable paper-based sensors.
Collapse
Affiliation(s)
- Giacomo Musile
- Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, P.le Scuro 10, 37134 Verona, Italy
| | - Cristian Grazioli
- Department of Agrifood, Environmental and Animal Science, University of Udine, Via Cotonificio 108, 33100 Udine, Italy
| | - Stefano Fornasaro
- Department of Chemical and Pharmaceutical Sciences, University of Trieste, Via L. Giorgeri 1, 34127 Trieste, Italy
| | - Nicolò Dossi
- Department of Agrifood, Environmental and Animal Science, University of Udine, Via Cotonificio 108, 33100 Udine, Italy
| | - Elio Franco De Palo
- Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, P.le Scuro 10, 37134 Verona, Italy
| | - Franco Tagliaro
- Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, P.le Scuro 10, 37134 Verona, Italy
- Laboratory of Pharmacokinetics and Metabolomics Analysis, Institute of Translational Medicine and Biotechnology, I.M. Sechenov First Moscow State Medical University, Bolshaya Pirogovskaya Street, 119991 Moscow, Russia
| | - Federica Bortolotti
- Unit of Forensic Medicine, Department of Diagnostics and Public Health, University of Verona, P.le Scuro 10, 37134 Verona, Italy
| |
Collapse
|
23
|
Paper-based dots and smartphone for detecting counterfeit country eggs. Food Chem 2023; 403:134484. [DOI: 10.1016/j.foodchem.2022.134484] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2022] [Revised: 09/19/2022] [Accepted: 09/29/2022] [Indexed: 11/18/2022]
|
24
|
Kulabhusan PK, Ray R, Ramachandra SG, Srinivasulu M, Hariharan A, Balaji K, Mani NK. Coalescing aptamers and liquid-crystals for sensing applications. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
25
|
Tian T, Zhang WY, Zhou HY, Peng LJ, Zhou X, Zhang H, Yang FQ. A Catechol-Meter Based on Conventional Personal Glucose Meter for Portable Detection of Tyrosinase and Sodium Benzoate. BIOSENSORS 2022; 12:bios12121084. [PMID: 36551051 PMCID: PMC9776396 DOI: 10.3390/bios12121084] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 11/22/2022] [Accepted: 11/24/2022] [Indexed: 05/28/2023]
Abstract
In this study, the personal glucose meter (PGM) was first used as a fast and user-friendly meter for analyzing catechol (CA) based on the reduction of the mediator K3[Fe(CN)6] to K4[Fe(CN)6] in the glucose test strip. Then, an easy, low-cost, and convenient PGM-based method for detecting tyrosinase (TYR) activity and sodium benzoate (SBA) was developed on the basis of the TYR-catalyzed reaction. In this method, CA is oxidized to form o-benzoquinone by TYR, thereby reducing the residual amount of CA and the PGM readout. On the other hand, SBA can inhibit the oxidation of CA catalyzed by TYR and increase the residual amount of CA after the enzymatic reaction. Therefore, the activity of TYR is proportional to the difference in the PGM readout of CA, and the concentration of SBA is positively correlated with the residual amount of CA. After the relevant experimental conditions were systematically optimized, the proposed PGM-based method for the detection of TYR and SBA was successfully validated. The liner ranges are 1.0-103.3 U/mL and 6.25-1000 ppm, and the quantification limits are 1.0 U/mL and 6.25 ppm for TYR and SBA, respectively. Moreover, the spiked recovery tests in normal human serum and carbonate beverages (i.e., Cola, Sprite, and Fanta) were performed, and the recoveries (91.6-106.8%) further confirm the applicability of the PGM-based method in real sample analysis.
Collapse
Affiliation(s)
- Tao Tian
- Chongqing Key Laboratory of High Active Traditional Chinese Drug Delivery System, Chongqing Medical and Pharmaceutical College, Chongqing 401331, China
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China
| | - Wei-Yi Zhang
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China
| | - Hang-Yu Zhou
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China
| | - Li-Jing Peng
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China
| | - Xi Zhou
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China
| | - Hao Zhang
- Chongqing Key Laboratory of High Active Traditional Chinese Drug Delivery System, Chongqing Medical and Pharmaceutical College, Chongqing 401331, China
| | - Feng-Qing Yang
- School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China
| |
Collapse
|
26
|
Xu S, Xu Z, Liu Z. Paper-Based Molecular-Imprinting Technology and Its Application. BIOSENSORS 2022; 12:595. [PMID: 36004991 PMCID: PMC9405720 DOI: 10.3390/bios12080595] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 07/28/2022] [Accepted: 08/02/2022] [Indexed: 11/24/2022]
Abstract
Paper-based analytical devices (PADs) are highly effective tools due to their low cost, portability, low reagent accumulation, and ease of use. Molecularly imprinted polymers (MIP) are also extensively used as biomimetic receptors and specific adsorption materials for capturing target analytes in various complex matrices due to their excellent recognition ability and structural stability. The integration of MIP and PADs (MIP-PADs) realizes the rapid, convenient, and low-cost application of molecular-imprinting analysis technology. This review introduces the characteristics of MIP-PAD technology and discusses its application in the fields of on-site environmental analysis, food-safety monitoring, point-of-care detection, biomarker detection, and exposure assessment. The problems and future development of MIP-PAD technology in practical application are also prospected.
Collapse
Affiliation(s)
| | - Zhigang Xu
- Faculty of Science, Kunming University of Science and Technology, Kunming 650500, China;
| | - Zhimin Liu
- Faculty of Science, Kunming University of Science and Technology, Kunming 650500, China;
| |
Collapse
|
27
|
Latex-Based Paper Devices with Super Solvent Resistance for On-the-Spot Detection of Metanil Yellow in Food Samples. FOOD ANAL METHOD 2022. [DOI: 10.1007/s12161-022-02322-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
AbstractThe following paper presents a construct for a paper-based device which utilizes latex as the hydrophobic material for the fabrication of its hydrophobic barrier, which was deposited onto the cellulose surface either by free-hand or stenciled drawing. This method demands the least amount of expertise and time from its use, enabling a simple and rapid fabrication experience. Several properties of the hydrophobic material were characterized, such as the hydro head and penetration rate, with the aim of assessing its robustness and stability. The presented hydrophobic barriers fabricated using this approach have a barrier width of 4 mm, a coating thickness of 208 µm, and a hydrophilic resolution of 446.5 µm. This fabrication modality boasts an excellent solvent resistance with regard to the hydrophobic barrier. These devices were employed for on-the-spot detection of Metanil Yellow, a banned food adulterant often used in curcumin and pigeon peas, within successful limits of detection (LOD) of 0.5% (w/w) and 0.25% (w/w), respectively. These results indicate the great potential this fabricated hydrophobic device has in numerous paper-based applications and other closely related domains, such as diagnostics and sensing, signalling its capacity to become commonplace in both industrial and domestic settings.
Collapse
|