Monreal G, Koenig SC, Huang J, Slaughter MS. Anatomical and Hemodynamic Characterization of Totally Artificial Hearts. ASAIO J 2024; 70:338-347. [PMID: 38557701 DOI: 10.1097/mat.0000000000002209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/04/2024] Open
Abstract
We characterize the anatomy and function of never before studied total artificial hearts (TAHs) using established methods for testing mechanical circulatory support (MCS) devices. A historical review of TAHs is also presented to aid in benchmarking performance metrics. Six TAHs, ranging from spooky Halloween beating hearts to a cute colorful plush heart, were imaged, instrumented (mock flow loops) to measure their pressure, volume, and flow, and qualitatively evaluated by 3rd party cardiac surgeons for anatomical accuracy and surgical considerations. Imaging of Claw, Beating, and Frankenstein TAHs revealed internal motors, circuit boards, and speakers. Gummy TAH was ranked favorite TAH for tactile realism, while Frankenstein TAH had the most favorable audible/visual indicators, including an illuminated Jacob's Ladder. Beating TAH demonstrated superior pulsatile hemodynamic performance compared to Claw TAH (16mL vs 1.3mL stroke volume). Light Up TAH and Gummy TAH functioned only as passive compliance chambers. Cute TAH rapidly exsanguinated due to its porosity (-3.0 L/min flow). These TAHs demonstrated a wide range of anatomical accuracy, surgeon appeal, unique features, and hemodynamic performance. While Claw TAH and Beating TAH successfully generated a modicum of pulsatility, we recommend the clinical community continue to support pre-clinical development of emerging or use of clinically-approved TAHs.
Collapse
Affiliation(s)
- Gretel Monreal
- From the Department of Cardiovascular and Thoracic Surgery, University of Louisville, Louisville, Kentucky
| | - Steven C Koenig
- From the Department of Cardiovascular and Thoracic Surgery, University of Louisville, Louisville, Kentucky
- Department of Bioengineering, University of Louisville, Louisville, Kentucky
| | - Jiapeng Huang
- Department of Anesthesiology and Perioperative Medicine, University of Louisville, Louisville, Kentucky
| | - Mark S Slaughter
- From the Department of Cardiovascular and Thoracic Surgery, University of Louisville, Louisville, Kentucky
| |
Collapse
|
2
|
Liang L, Wang X, Chen D, Sethu P, Giridharan GA, Wang Y, Wang Y, Qin KR. Study on the hemodynamic effects of different pulsatile working modes of a rotary blood pump using a microfluidic platform that realizes in vitro cell culture effectively. LAB ON A CHIP 2024; 24:2428-2439. [PMID: 38625094 DOI: 10.1039/d4lc00159a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/17/2024]
Abstract
Rotary blood pumps (RBPs) operating at a constant speed generate non-physiologic blood pressure and flow rate, which can cause endothelial dysfunction, leading to adverse clinical events in peripheral blood vessels and other organs. Notably, pulsatile working modes of the RBP can increase vascular pulsatility to improve arterial endothelial function. However, the laws and related mechanisms of differentially regulating arterial endothelial function under different pulsatile working modes are still unclear. This knowledge gap hinders the optimal selection of the RBP working modes. To address these issues, this study developed a multi-element in vitro endothelial cell culture system (ECCS), which could realize in vitro cell culture effectively and accurately reproduce blood pressure, shear stress, and circumferential strain in the arterial endothelial microenvironment. Performance of this proposed ECCS was validated with numerical simulation and flow experiments. Subsequently, this study investigated the effects of four different pulsation frequency modes that change once every 1-4-fold cardiac cycles (80, 40, 80/3, and 20 cycles per min, respectively) of the RBP on the expression of nitric oxide (NO) and reactive oxygen species (ROS) in endothelial cells. Results indicated that the 2-fold and 3-fold cardiac cycles significantly increased the production of NO and prevented the excessive generation of ROS, potentially minimizing the occurrence of endothelial dysfunction and related adverse events during the RBP support, and were consistent with animal study findings. In general, this study may provide a scientific basis for the optimal selection of the RBP working modes and potential treatment options for heart failure.
Collapse
Affiliation(s)
- Lixue Liang
- Institute of Cardio-Cerebrovascular Medicine, Central Hospital of Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
- School of Mechanical Engineering, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
| | - Xueying Wang
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
| | - Dong Chen
- Institute of Cardio-Cerebrovascular Medicine, Central Hospital of Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
| | - Palaniappan Sethu
- Division of Cardiovascular Disease, Department of Medicine, School of Medicine and Department of Biomedical Engineering, School of Engineering, University of Alabama at Birmingham, Birmingham, AL, USA
| | | | - Yanxia Wang
- School of Rehabilitation Medicine, Shandong Second Medical University, Weifang 261053, Shandong Province, P. R. China
| | - Yu Wang
- Institute of Cardio-Cerebrovascular Medicine, Central Hospital of Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China.
| | - Kai-Rong Qin
- Institute of Cardio-Cerebrovascular Medicine, Central Hospital of Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China
- School of Biomedical Engineering, Faculty of Medicine, Dalian University of Technology, Dalian 116024, Liaoning Province, P. R. China.
| |
Collapse
|
3
|
Kuroda T, Miyagi C, Polakowski AR, Flick CR, Kuban BD, Fukamachi K, Karimov JH. Cleveland Clinic Continuous-Flow Total Artificial Heart: Progress Report and Technology Update. ASAIO J 2024; 70:116-123. [PMID: 37851000 PMCID: PMC10842968 DOI: 10.1097/mat.0000000000002076] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2023] Open
Abstract
Cleveland Clinic's continuous-flow total artificial heart (CFTAH) is being developed at our institution and has demonstrated system reliability and optimal performance. Based on the results from recent chronic in vivo experiments, CFTAH has been revised, especially to improve biocompatibility. The purpose of this article is to report our progress in developing CFTAH. To improve biocompatibility, the right impeller, the pump housing, and the motor were reviewed for design revision. Updated design features were based on computational fluid dynamics analysis and observations from in vitro and in vivo studies. A new version of CFTAH was created, manufactured, and tested. All hemodynamic and pump-related parameters were observed and found to be within the intended ranges, and the new CFTAH yielded acceptable biocompatibility. Cleveland Clinic's continuous-flow total artificial heart has demonstrated reliable performance, and has shown satisfactory progress in its development.
Collapse
Affiliation(s)
- Taiyo Kuroda
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Chihiro Miyagi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Anthony R. Polakowski
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Christine R. Flick
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Barry D. Kuban
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland Clinic, Cleveland, Ohio, USA
- Kaufman Center for Heart Failure Treatment and Recovery, Section of Heart Failure and Cardiac Transplant Medicine, Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland, OH
| | - Jamshid H. Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland Clinic, Cleveland, Ohio, USA
- Kaufman Center for Heart Failure Treatment and Recovery, Section of Heart Failure and Cardiac Transplant Medicine, Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland, OH
| |
Collapse
|
4
|
Kuroda T, Miyagi C, Polakowski AR, Flick CR, Kuban BD, Fukamachi K, Karimov JH. Preservation of pulsatility with universal ventricular assist device: In vitro assessment for biventricular support. Artif Organs 2024; 48:182-190. [PMID: 37787082 DOI: 10.1111/aor.14656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 08/08/2023] [Accepted: 09/21/2023] [Indexed: 10/04/2023]
Abstract
BACKGROUND The objective of this study was to assess the pulsatility preservation capability of the universal ventricular assist device (UVAD) when used as a biventricular assist device (BVAD). This evaluation was conducted through an in vitro experiment, utilizing a pulsatile biventricular circulatory mock loop. METHODS Two UVAD pumps were tested in a dual setup (BVAD) in the circulatory model with the simulated conditions of left heart failure (HF), right HF, and moderate/severe biventricular HF (BHF). The total flow, aortic pulse pressure, the pulse augmentation factor (PAF), the energy-equivalent pressure (EEP), and the surplus hemodynamic energy (SHE) were observed at various pump speeds to evaluate the pulsatility. RESULTS The aortic pulse pressure increased from the baseline (without pump) in all simulated hemodynamic conditions. The PAF ranged from 17%-35% in healthy, left HF, right HF, and mild BHF conditions, with the highest PAF of 90% being observed in the severe BHF condition. The EEP correlated with LVAD flow in all groups (R2 = 0.87-0.97) and increased from the baseline in all cases. The SHE peaked at approximately 5-6 L/min of LVAD support and was likely to decrease at higher LVAD pump flow. The largest decrease in SHE from the baseline, 53%, was observed in the mild BHF conditions with the highest LVAD and RVAD support. CONCLUSIONS The UVAD successfully demonstrated the ability to preserve pulsatility in vitro, and to optimize the cardiac output, as an isolated circulatory support device option (RVAD or LVAD) and when used for BVAD support.
Collapse
Affiliation(s)
- Taiyo Kuroda
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Chihiro Miyagi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Anthony R Polakowski
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Christine R Flick
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Barry D Kuban
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Cardiovascular Medicine, Kaufman Center for Heart Failure Treatment and Recovery, Section of Heart Failure and Cardiac Transplant Medicine, Cleveland, Ohio, USA
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Cardiovascular Medicine, Kaufman Center for Heart Failure Treatment and Recovery, Section of Heart Failure and Cardiac Transplant Medicine, Cleveland, Ohio, USA
- Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA
| | - Jamshid H Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
- Department of Cardiovascular Medicine, Kaufman Center for Heart Failure Treatment and Recovery, Section of Heart Failure and Cardiac Transplant Medicine, Cleveland, Ohio, USA
- Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
5
|
Shida S, Tsushima K, Osa M, Timms DL, Masuzawa T. Effects of biventricular shunt on pump characteristics in a maglev total artificial heart. Int J Artif Organs 2023; 46:636-643. [PMID: 37908140 DOI: 10.1177/03913988231209010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2023]
Abstract
Severe left ventricular failure can progress to right ventricular failure, necessitating alternatives to heart transplantation, such as total artificial heart (TAH) treatment. Conventional TAHs encounter challenges associated with miniaturization and hemocompatibility owing to their reliance on mechanical valves and bearings. A magnetically levitated TAH (IB-Heart) was developed, utilizing a magnetic bearing. The IB-Heart features a distinctive biventricular shunt channel situated between the flow paths of the left and right centrifugal blood pumps, simplifying and miniaturizing its control system. However, the impact of these shunt channels remains underexplored. This study aimed to investigate the effects of shunt flow on pump characteristics and assess the IB-Heart's potential to regulate flow balance between systemic and pulmonary circulation. At a rotational speed of 2000 rpm and flow rate range of 0-10 L/min, shunt flow exhibited a minor impact, with a 1.4 mmHg (1.3%) effect on pump characteristics. Shunt flow variation of about 0.13 L/min correlated with a 10 mmHg pressure difference between the pumps' afterload and preload conditions. This variance was linked to changes in the inlet flow rates of the left and right pumps, signifying the ventricular shunt structure's capacity to mirror the function of an atrial shunt in alleviating pulmonary congestion. The IB-Heart's ventricular shunt structure enables passive regulation of left-right flow balance. The findings establish a fundamental technical groundwork for the development of IB-Hearts and TAHs with similar shunt structures. The innovative coupling of centrifugal pumps and the resultant effects on flow dynamics contribute to the advancement of TAH technology.
Collapse
Affiliation(s)
- Shuya Shida
- Faculty of Science and Engineering, Toyo University, Kawagoe, Saitama, Japan
| | - Kenichi Tsushima
- Graduate School of Science and Engineering, Ibaraki University, Hitachi, Ibaraki, Japan
| | - Masahiro Osa
- Graduate School of Science and Engineering, Ibaraki University, Hitachi, Ibaraki, Japan
| | | | - Toru Masuzawa
- Graduate School of Science and Engineering, Ibaraki University, Hitachi, Ibaraki, Japan
| |
Collapse
|
6
|
Kuroda T, Kuban BD, Miyamoto T, Miyagi C, Polakowski AR, Flick CR, Karimov JH, Fukamachi K. Artificial Deep Neural Network for Sensorless Pump Flow and Hemodynamics Estimation During Continuous-Flow Mechanical Circulatory Support. ASAIO J 2023; 69:649-657. [PMID: 37018765 DOI: 10.1097/mat.0000000000001926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/07/2023] Open
Abstract
The objective of this study was to compare the estimates of pump flow and systemic vascular resistance (SVR) derived from a mathematical regression model to those from an artificial deep neural network (ADNN). Hemodynamic and pump-related data were generated using both the Cleveland Clinic continuous-flow total artificial heart (CFTAH) and pediatric CFTAH on a mock circulatory loop. An ADNN was trained with generated data, and a mathematical regression model was also generated using the same data. Finally, the absolute error for the actual measured data and each set of estimated data were compared. A strong correlation was observed between the measured flow and the estimated flow using either method (mathematical, R = 0.97, p < 0.01; ADNN, R = 0.99, p < 0.01). The absolute error was smaller in the ADNN estimation (mathematical, 0.3 L/min; ADNN 0.12 L/min; p < 0.01). Furthermore, strong correlation was observed between measured and estimated SVR (mathematical, R = 0.97, p < 0.01; ADNN, R = 0.99, p < 0.01). The absolute error for ADNN estimation was also smaller than that of the mathematical estimation (mathematical, 463 dynes·sec·cm -5 ; ADNN, 123 dynes·sec·cm -5 , p < 0.01). Therefore, in this study, ADNN estimation was more accurate than mathematical regression estimation. http://links.lww.com/ASAIO/A991.
Collapse
Affiliation(s)
- Taiyo Kuroda
- From the Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Barry D Kuban
- From the Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Takuma Miyamoto
- From the Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Chihiro Miyagi
- From the Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Anthony R Polakowski
- From the Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Christine R Flick
- From the Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Jamshid H Karimov
- From the Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
- Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland Clinic, Cleveland, Ohio
| | - Kiyotaka Fukamachi
- From the Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
- Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
7
|
Tan Z, Huo M, Qin K, El-Baz AS, Sethu P, Wang Y, Giridharan GA. A sensorless, physiologic feedback control strategy to increase vascular pulsatility for rotary blood pumps. Biomed Signal Process Control 2023; 83:104640. [PMID: 36936779 PMCID: PMC10019090 DOI: 10.1016/j.bspc.2023.104640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/18/2023]
Abstract
Continuous flow rotary blood pumps (RBP) operating clinically at constant rotational speeds cannot match cardiac demand during varying physical activities, are susceptible to suction, diminish vascular pulsatility, and have an increased risk of adverse events. A sensorless, physiologic feedback control strategy for RBP was developed to mitigate these limitations. The proposed algorithm used intrinsic pump speed to obtain differential pump speed (ΔRPM). The proposed gain-scheduled proportional-integral controller, switching of setpoints between a higher pump speed differential setpoint (ΔRPM Hr ) and a lower pump speed differential setpoint (ΔRPM Lr ), generated pulsatility and physiologic perfusion, while avoiding suction. The switching between ΔRPM Hr and ΔRPM Lr setpoints occurred when the measured ΔRPM reached the pump differential reference setpoint. In-silico tests were implemented to assess the proposed algorithm during rest, exercise, a rapid 3-fold pulmonary vascular resistance increase, rapid change from exercise to rest, and compared with maintaining a constant pump speed setpoint. The proposed control algorithm augmented aortic pressure pulsatility to over 35 mmHg during rest and around 30 mmHg during exercise. Significantly, ventricular suction was avoided, and adequate cardiac output was maintained under all simulated conditions. The performance of the sensorless algorithm using estimation was similar to the performance of sensor-based method. This study demonstrated that augmentation of vascular pulsatility was feasible while avoiding ventricular suction and providing physiological pump outflows. Augmentation of vascular pulsatility can minimize adverse events that have been associated with diminished pulsatility. Mock circulation and animal studies would be conducted to validate these results.
Collapse
Affiliation(s)
- Zhehuan Tan
- School of Biomedical Engineering, Dalian University of Technology, Dalian, China
| | - Mingming Huo
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| | - Kairong Qin
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| | - Ayman S El-Baz
- Department of Bioengineering, University of Louisville, Louisville, KY, USA
| | - Palaniappan Sethu
- Department of Biomedical Engineering, School of Engineering, University of Alabama at Birmingham, Birmingham, AL, USA
| | - Yu Wang
- School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
| | | |
Collapse
|
8
|
Bornoff J, Najar A, Fresiello L, Finocchiaro T, Perkins IL, Gill H, Cookson AN, Fraser KH. Fluid-structure interaction modelling of a positive-displacement Total Artificial Heart. Sci Rep 2023; 13:5734. [PMID: 37059748 PMCID: PMC10104863 DOI: 10.1038/s41598-023-32141-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Accepted: 03/23/2023] [Indexed: 04/16/2023] Open
Abstract
For those suffering from end-stage biventricular heart failure, and where a heart transplantation is not a viable option, a Total Artificial Heart (TAH) can be used as a bridge to transplant device. The Realheart TAH is a four-chamber artificial heart that uses a positive-displacement pumping technique mimicking the native heart to produce pulsatile flow governed by a pair of bileaflet mechanical heart valves. The aim of this work was to create a method for simulating haemodynamics in positive-displacement blood pumps, using computational fluid dynamics with fluid-structure interaction to eliminate the need for pre-existing in vitro valve motion data, and then use it to investigate the performance of the Realheart TAH across a range of operating conditions. The device was simulated in Ansys Fluent for five cycles at pumping rates of 60, 80, 100 and 120 bpm and at stroke lengths of 19, 21, 23 and 25 mm. The moving components of the device were discretised using an overset meshing approach, a novel blended weak-strong coupling algorithm was used between fluid and structural solvers, and a custom variable time stepping scheme was used to maximise computational efficiency and accuracy. A two-element Windkessel model approximated a physiological pressure response at the outlet. The transient outflow volume flow rate and pressure results were compared against in vitro experiments using a hybrid cardiovascular simulator and showed good agreement, with maximum root mean square errors of 15% and 5% for the flow rates and pressures respectively. Ventricular washout was simulated and showed an increase as cardiac output increased, with a maximum value of 89% after four cycles at 120 bpm 25 mm. Shear stress distribution over time was also measured, showing that no more than [Formula: see text]% of the total volume exceeded 150 Pa at a cardiac output of 7 L/min. This study showed this model to be both accurate and robust across a wide range of operating points, and will enable fast and effective future studies to be undertaken on current and future generations of the Realheart TAH.
Collapse
Affiliation(s)
- Joseph Bornoff
- Department of Mechanical Engineering, University of Bath, Bath, UK
| | - Azad Najar
- Scandinavian Real Heart AB, Västerås, Sweden
| | - Libera Fresiello
- Faculty of Science and Technology, University of Twente, Twente, The Netherlands
| | | | | | - Harinderjit Gill
- Department of Mechanical Engineering, University of Bath, Bath, UK
- Centre for Therapeutic Innovation, University of Bath, Bath, UK
| | - Andrew N Cookson
- Department of Mechanical Engineering, University of Bath, Bath, UK
- Centre for Therapeutic Innovation, University of Bath, Bath, UK
| | - Katharine H Fraser
- Department of Mechanical Engineering, University of Bath, Bath, UK.
- Centre for Therapeutic Innovation, University of Bath, Bath, UK.
| |
Collapse
|
9
|
Kuroda T, Miyagi C, Fukamachi K, Karimov JH. Biventricular assist devices and total artificial heart: Strategies and outcomes. Front Cardiovasc Med 2023; 9:972132. [PMID: 36684573 PMCID: PMC9853410 DOI: 10.3389/fcvm.2022.972132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Accepted: 12/14/2022] [Indexed: 01/09/2023] Open
Abstract
In contrast to the advanced development of the left ventricular assist device (LVAD) therapy for advanced heart failure, the mechanical circulatory support (MCS) with biventricular assist device (BVAD) and total artificial heart (TAH) options remain challenging. The treatment strategy of BVAD and TAH therapy largely depends on the support duration. For example, an extracorporeal centrifugal pump, typically referred to as a temporary surgical extracorporeal right ventricular assist device, is implanted for the short term with acute right ventricular failure following LVAD implantation. Meanwhile, off-label use of a durable implantable LVAD is a strategy for long-term right ventricular support. Hence, this review focuses on the current treatment strategies and clinical outcomes based on each ventricle support duration. In addition, the issue of heart failure post-heart transplantation (post-HT) is explored. We will discuss MCS therapy options for post-HT recipients.
Collapse
Affiliation(s)
- Taiyo Kuroda
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States
| | - Chihiro Miyagi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States,Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, OH, United States
| | - Jamshid H. Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States,Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, OH, United States,*Correspondence: Jamshid H. Karimov,
| |
Collapse
|
10
|
Xu KW, Gao Q, Wan M, Zhang K. Mock circulatory loop applications for testing cardiovascular assist devices and in vitro studies. Front Physiol 2023; 14:1175919. [PMID: 37123281 PMCID: PMC10133581 DOI: 10.3389/fphys.2023.1175919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 04/03/2023] [Indexed: 05/02/2023] Open
Abstract
The mock circulatory loop (MCL) is an in vitro experimental system that can provide continuous pulsatile flows and simulate different physiological or pathological parameters of the human circulation system. It is of great significance for testing cardiovascular assist device (CAD), which is a type of clinical instrument used to treat cardiovascular disease and alleviate the dilemma of insufficient donor hearts. The MCL installed with different types of CADs can simulate specific conditions of clinical surgery for evaluating the effectiveness and reliability of those CADs under the repeated performance tests and reliability tests. Also, patient-specific cardiovascular models can be employed in the circulation of MCL for targeted pathological study associated with hemodynamics. Therefore, The MCL system has various combinations of different functional units according to its richful applications, which are comprehensively reviewed in the current work. Four types of CADs including prosthetic heart valve (PHV), ventricular assist device (VAD), total artificial heart (TAH) and intra-aortic balloon pump (IABP) applied in MCL experiments are documented and compared in detail. Moreover, MCLs with more complicated structures for achieving advanced functions are further introduced, such as MCL for the pediatric application, MCL with anatomical phantoms and MCL synchronizing multiple circulation systems. By reviewing the constructions and functions of available MCLs, the features of MCLs for different applications are summarized, and directions of developing the MCLs are suggested.
Collapse
Affiliation(s)
- Ke-Wei Xu
- Department of Engineering Mechanics, School of Aeronautics and Astronautics, Zhejiang University, Hangzhou, China
| | - Qi Gao
- Department of Engineering Mechanics, School of Aeronautics and Astronautics, Zhejiang University, Hangzhou, China
- *Correspondence: Qi Gao,
| | - Min Wan
- Shandong Institute of Medical Device and Pharmaceutical Packaging Inspection, Jinan, China
| | - Ke Zhang
- Shandong Institute of Medical Device and Pharmaceutical Packaging Inspection, Jinan, China
| |
Collapse
|
11
|
Kuroda T, Miyagi C, Fukamachi K, Karimov JH. Mechanical circulatory support devices and treatment strategies for right heart failure. Front Cardiovasc Med 2022; 9:951234. [PMID: 36211548 PMCID: PMC9538150 DOI: 10.3389/fcvm.2022.951234] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Accepted: 08/29/2022] [Indexed: 11/16/2022] Open
Abstract
The importance of right heart failure (RHF) treatment is magnified over the years due to the increased risk of mortality. Additionally, the multifactorial origin and pathophysiological mechanisms of RHF render this clinical condition and the choices for appropriate therapeutic target strategies remain to be complex. The recent change in the United Network for Organ Sharing (UNOS) allocation criteria of heart transplant may have impacted for the number of left ventricular assist devices (LVADs), but LVADs still have been widely used to treat advanced heart failure, and 4.1 to 7.4% of LVAD patients require a right ventricular assist device (RVAD). In addition, patients admitted with primary left ventricular failure often need right ventricular support. Thus, there is unmet need for temporary or long-term support RVAD implantation exists. In RHF treatment with mechanical circulatory support (MCS) devices, the timing of the intervention and prediction of duration of the support play a major role in successful treatment and outcomes. In this review, we attempt to describe the prevalence and pathophysiological mechanisms of RHF origin, and provide an overview of existing treatment options, strategy and device choices for MCS treatment for RHF.
Collapse
Affiliation(s)
- Taiyo Kuroda
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States
| | - Chihiro Miyagi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States
- Department of Biomedical Engineering, Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, OH, United States
| | - Jamshid H. Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, United States
- Department of Biomedical Engineering, Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, OH, United States
| |
Collapse
|
12
|
Khelghatibana M, Goodin MS, Yaksh M, Horvath DJ, Kuban BD, Fukamachi K, Karimov JH. Total Artificial Heart Computational Fluid Dynamics: Modeling of Stator Bore Design Effects on Journal-Bearing Performance. ASAIO J 2022; 68:655-662. [PMID: 34380949 PMCID: PMC8828802 DOI: 10.1097/mat.0000000000001556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Cleveland Clinic's continuous-flow total artificial heart (CFTAH) is a double-ended centrifugal blood pump that has a single rotating assembly with an embedded magnet, which is axially and radially suspended by a balance of magnetic and hydrodynamic forces. The key to the radial suspension is a radial offset between the stator bearing bore and the magnet's steel laminations. This offset applies a radial magnetic force, which is balanced by a hydrodynamic force as the rotating assembly moves to a "force-balanced" radial position. The journal-bearing blood passage is a narrow flow path between the left and right impellers. The intent of this study was to determine the impact of the stator-bearing bore radius on the journal-bearing hydraulic performance while satisfying the geometric design constraints imposed by the pump and motor configuration. Electromagnetic forces on the journal bearing were calculated using the ANSYS EMAG program, Version 18 (ANSYS, Canonsburg, PA). ANSYS CFX Version 19.2 was then used to model the journal-bearing flow paths of the most recent design of the CFTAH. A transient, moving mesh approach was used to locate the steady state, force-balanced position of the rotating assembly. The blood was modeled as a non-Newtonian fluid. The computational fluid dynamics simulations showed that by increasing stator bore radius, rotor power, stator wall average shear stress, and blood residence time in journal-bearing decrease, while blood net flow rate through the bearing increases. The results were used to select a new bearing design that provides an improved performance compared with the baseline design. The performance of the new CFTAH-bearing design will be confirmed through upcoming in vitro and in vivo testing.
Collapse
Affiliation(s)
| | | | | | | | - Barry D. Kuban
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
- Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland Clinic, Cleveland, OH
| | - Jamshid H. Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
- Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland Clinic, Cleveland, OH
| |
Collapse
|
13
|
Kuroda T, Miyamoto T, Miyagi C, Polakowski AR, Flick CR, Kuban BD, Voros GB, Such K, Fukamachi K, Karimov JH. Pulsatility hemodynamics during speed modulation of continuous-flow total artificial heart in a chronic in vivo. Artif Organs 2022; 46:1555-1563. [PMID: 35318688 PMCID: PMC9543567 DOI: 10.1111/aor.14237] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2021] [Revised: 02/09/2022] [Accepted: 03/14/2022] [Indexed: 11/29/2022]
Abstract
Background The evaluation of pulsatile flow created by the new Cleveland Clinic continuous‐flow total artificial heart (CFTAH100), which has a re‐designed right impeller and motor, had not been tested in vivo. The purpose of this study was to evaluate the feasibility of pulsatility with the CFTAH100 during the application of pump speed modulation protocols in a chronic animal model. Methods A 30‐day chronic animal experiment was conducted with a calf. Five pulsatile studies were performed on the alert animal. The mean pump speed was set at 2800 rpm, and modulated sinusoidally within a range of 0 to ± 35% of mean speed, in increments of 5% at 80 beats per minute (bpm). The pressures and pump flow were collected and a pulsatility index (PI) was calculated. Results The calf was supported with the CFTAH100 without any major complications. The maximum and minimum pump flows changed significantly from baseline in all conditions, while the mean pump flow did not change. All flow pulsatility (FP) readings in all conditions significantly increased from baseline, and the percent modulation (%S) and FP had a strong positive correlation (r = 0.99, p < 0.01). The PI also increased significantly in all conditions (maximum at %S of 35%, 2.2 ± 0.05, p < 0.01), and a positive correlation between %S and PI (r = 0.99, p < 0.01) was observed. Conclusion The CFTAH100 showed the feasibility of creating pulsatile circulation with sinusoidal pump speed modulation.
Collapse
Affiliation(s)
- Taiyo Kuroda
- Department of Biomedical Engineering, Cleveland Clinic Lerner Research Institute, Cleveland, Ohio, USA
| | - Takuma Miyamoto
- Department of Biomedical Engineering, Cleveland Clinic Lerner Research Institute, Cleveland, Ohio, USA
| | - Chihiro Miyagi
- Department of Biomedical Engineering, Cleveland Clinic Lerner Research Institute, Cleveland, Ohio, USA
| | - Anthony R Polakowski
- Department of Biomedical Engineering, Cleveland Clinic Lerner Research Institute, Cleveland, Ohio, USA
| | - Christine R Flick
- Department of Biomedical Engineering, Cleveland Clinic Lerner Research Institute, Cleveland, Ohio, USA
| | - Barry D Kuban
- Department of Biomedical Engineering, Cleveland Clinic Lerner Research Institute, Cleveland, Ohio, USA
| | - George B Voros
- Biological Resources Unit, Cleveland Clinic, Cleveland, Ohio, USA
| | - Kimberly Such
- Biological Resources Unit, Cleveland Clinic, Cleveland, Ohio, USA
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Cleveland Clinic Lerner Research Institute, Cleveland, Ohio, USA.,Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA
| | - Jamshid H Karimov
- Department of Biomedical Engineering, Cleveland Clinic Lerner Research Institute, Cleveland, Ohio, USA.,Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
14
|
Liu H, Liu S, Ma X. Varying speed modulation of continuous-flow left ventricular assist device based on cardiovascular coupling numerical model. Comput Methods Biomech Biomed Engin 2020; 24:956-972. [PMID: 33347766 DOI: 10.1080/10255842.2020.1861601] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
Continuous-flow left ventricular assist devices (CFLVADs) routinely operate at a constant speed for the support of a failing heart, which decreases the pulsatility in the arteries. Some late complications could be related to a long-term lack of pulsatility. Modulating the CFLVAD speed is a solution to enhance the pulsatility. The purpose of this study is to modulate multiple varying speed patterns and investigate their effects on the ventricle and vascular system. A cardiovascular coupling numerical model is developed to provide a simulation platform for testing the varying speed patterns. The varying speed patterns are modulated by combining the shape, amplitude, frequency, phase shift, and pulsatile duty cycle of the speed profile. The influence of varying speed support is examined by analyzing the indexes of pulsatility, indexes of ventricular unloading, and hemodynamic variables. The results show that the synchronous counterpulsation pattern can effectively reduce the ventricular unloading indexes, whereas the low-frequency asynchronous pattern can effectively increase the vascular pulsatility indexes. Also, the hemodynamics with synchronous varying speed support is more physiological than that with asynchronous varying speed support. This study provides valuable insight for further optimization of varying speed modulation by weighing vascular pulsatility, ventricular unloading, and hemodynamics.
Collapse
Affiliation(s)
- Hongtao Liu
- School of Electrical Engineering, Shandong University, Jinan, PR China
| | - Shuqin Liu
- School of Electrical Engineering, Shandong University, Jinan, PR China
| | - Xiaoxu Ma
- School of Electrical Engineering, Shandong University, Jinan, PR China
| |
Collapse
|
15
|
Modeling of Virtual Mechanical Circulatory Hemodynamics for Biventricular Heart Failure Support. Cardiovasc Eng Technol 2020; 11:699-707. [PMID: 33215365 DOI: 10.1007/s13239-020-00501-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Accepted: 11/05/2020] [Indexed: 10/22/2022]
Abstract
OBJECTIVE In this study, a mechanical circulatory support simulation tool was used to investigate the application of a unique device with two centrifugal pumps and one motor for the biventricular assist device (BVAD) support application. Several conditions-including a range of combined left and right systolic heart failure severities, aortic and pulmonary valve regurgitation, and combinations of high and low systemic and pulmonary vascular resistances-were considered in the simulation matrix. Relative advantages and limitations of using the device in BVAD applications are discussed. METHODS The simulated BVAD pump was based on the Cleveland Clinic pediatric continuous-flow total artificial heart (P-CFTAH), which is currently under development. Different combined disease states (n = 10) were evaluated to model the interaction with the BVAD, considering combinations of normal heart, moderate failure and severe systolic failure of the left and right ventricles, regurgitation of the aortic and pulmonary valves and combinations of vascular resistance. The virtual mock loop simulation tool (MATLAB; MathWorks®, Natick, MA) simulates the hemodynamics at the pump ports using a lumped-parameter model for systemic/pulmonary circulation characteristic inputs (values for impedance, systolic and diastolic ventricular compliance, beat rate, and blood volume), and characteristics of the cardiac chambers and valves. RESULTS Simulation results showed that this single-pump BVAD can provide regulated support of up to 5 L/min over a range of combined heart failure states and is suitable for smaller adult and pediatric support. However, good self-regulation of the atrial pressure difference was not maintained with the introduction of aortic valve regurgitation or high systemic vascular resistance when combined with low pulmonary vascular resistance. CONCLUSIONS This initial in silico study demonstrated that use of the P-CFTAH as a BVAD supports cardiac output and arterial pressure in biventricular heart failure conditions. A similar but larger device would be required for a large adult patient who needs more than 5 L/min of support.
Collapse
|
16
|
Jurney PL, Glynn JJ, Dykan IV, Hagen MW, Kaul S, Wampler RK, Hinds MT, Giraud GD. Characterization of a pulsatile rotary total artificial heart. Artif Organs 2020; 45:135-142. [PMID: 32857895 DOI: 10.1111/aor.13810] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 08/18/2020] [Accepted: 08/19/2020] [Indexed: 11/27/2022]
Abstract
This article describes the properties and performance of a rotary total artificial heart (TAH) that produces inherently pulsatile flow. The hydraulic performance of the TAH was characterized using a mock circulatory loop to simulate four physiologically relevant conditions: baseline flow, increased flow, systemic hypertension, and pulmonary hypertension. The pump has a variable shuttle rate (beats per minute), percentage dwell time, and angular velocity on either side (revolutions per minute), which allows for full control of the flow rate and pulsatility over a range of healthy and pathologic pressures and flow rates. The end-to-end length and displacement volume of the TAH are 9.8 cm and 130 mL, respectively, allowing it to fit in smaller chest cavities including those of smaller adults and juvenile humans.
Collapse
Affiliation(s)
- Patrick L Jurney
- Department of Biomedical Engineering, San José State University, San Jose, CA, USA.,Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| | | | - Igor V Dykan
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| | - Matthew W Hagen
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| | - Sanjiv Kaul
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| | - Richard K Wampler
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| | - Monica T Hinds
- Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA.,Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| | - George D Giraud
- Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR, USA
| |
Collapse
|
17
|
Karimov JH, Gao S, Fukamachi K, Grady P. Continuous-flow total artificial heart port-to-port connection technique using dedicated de-airing sleeve. Perfusion 2020; 35:861-864. [PMID: 32375546 DOI: 10.1177/0267659120917862] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Preventing the introduction of air while a mechanical circulatory support device is being implanted is critical for successful outcomes. A substantial amount of air may be introduced into the circulation during the pump-to-outflow and/or pump-to-inflow port connection, which can be detrimental to optimal pump function and long-term survival. We have developed a novel connecting sleeve that enables an airless connection of the continuous-flow total artificial heart to the conduits. Herein, we describe the device design and surgical techniques evaluated in vivo.
Collapse
Affiliation(s)
- Jamshid H Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Shengqiang Gao
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA.,Polymer Lab, Medical Device Solutions, Cleveland Clinic, Cleveland, OH, USA
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Patrick Grady
- Perfusion Services, Miller Family Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|
18
|
Karimov JH, Horvath DJ, Miyamoto T, Kado Y, Gao S, Kuban BD, Polakowski AR, Sale S, Fukamachi K. First In Vivo Experience With Biventricular Circulatory Assistance Using a Single Continuous Flow Pump. Semin Thorac Cardiovasc Surg 2020; 32:456-465. [PMID: 32371175 DOI: 10.1053/j.semtcvs.2020.03.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Accepted: 03/26/2020] [Indexed: 11/11/2022]
Abstract
Biventricular assist device (BVAD) implantation is the treatment of choice in patients with severe biventricular heart failure and cardiogenic shock. Our team has developed a miniaturized continuous flow, double-ended centrifugal pump intended for total artificial heart implant (CFTAH). The purpose of this initial in vivo study was to demonstrate that the scaled-down CFTAH (P-CFTAH) can be appropriate for BVAD support. The P-CFTAH was implanted in 4 acute lambs (average weight, 41.5 ± 2.8 kg) through a median sternotomy. The cannulation was performed through the left and right atria, and cannulae length adjustment was performed for atrial and ventricular cannulation. The BVAD system was tested at 3 pump speeds (3000, 4500, and 6000 rpm). The BVAD performed very well for both atrial and ventricular cannulation within the 3000-6000 rpm range. Stable hemodynamics were maintained after implantation of the P-CFTAH. The self-regulating performance of the system in vivo was demonstrated by the left (LAP) and right (RAP) pressure difference (LAP-RAP) falling predominantly within the range of -5 to 10 mm Hg with variation, in addition to in vitro assessment of left and right heart failure conditions. Left and right pump flows and total flow increased as the BVAD speed was increased. This initial in vivo testing of the BVAD system demonstrated satisfactory device performance and self-regulation for biventricular heart failure support over a wide range of conditions. The BVAD system keeps the atrial pressure difference within bounds and maintains acceptable cardiac output over a wide range of hemodynamic conditions.
Collapse
Affiliation(s)
- Jamshid H Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio.
| | | | - Takuma Miyamoto
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Yuichiro Kado
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Shengqiang Gao
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Barry D Kuban
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Anthony R Polakowski
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Shiva Sale
- Anesthesiology Institute, Cleveland Clinic, Cleveland, Ohio
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
19
|
Miyamoto T, Horvath DJ, Horvath DW, Kuban BD, Fukamachi K, Karimov JH. Analysis of Cleveland Clinic continuous-flow total artificial heart performance using the Virtual Mock Loop: Comparison with an in vivo study. Artif Organs 2020; 44:375-383. [PMID: 31573677 DOI: 10.1111/aor.13574] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2019] [Revised: 09/16/2019] [Accepted: 09/24/2019] [Indexed: 11/28/2022]
Abstract
The Virtual Mock Loop (VML) is a mathematical model designed to simulate mechanism of the human cardiovascular system interacting with mechanical circulatory support devices. Here, we aimed to mimic the hemodynamic performance of Cleveland Clinic's self-regulating continuous-flow total artificial heart (CFTAH) via VML and evaluate the accuracy of the VML compared with an in vivo acute animal study. The VML reproduced 124 hemodynamic conditions from three acute in vivo experiments in calves. Systemic/pulmonary vascular resistances, pump rotational speed, pulsatility, and pulse rate were set for the VML from in vivo data. We compared outputs (pump flow, left and right pump pressure rises, and atrial pressure difference) between the two systems. The pump performance curves all fell in the designed range. There was a strong correlation between the VML and the in vivo study in the left pump flow (r2 = 0.84) and pressure rise (r2 = 0.80), and a moderate correlation in right pressure rise (r2 = 0.52) and atrial pressure difference (r2 = 0.59). Although there is room for improvement in simulating right-sided pump performance of self-regulating CFTAH, the VML acceptably simulated the hemodynamics observed in an in vivo study. These results indicate that pump flow and pressure rise can be estimated from vascular resistances and pump settings.
Collapse
Affiliation(s)
- Takuma Miyamoto
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | | | | | - Barry D Kuban
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
- Medical Device Solutions (Electronics Core), Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Jamshid H Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|
20
|
Kado Y, Miyamoto T, Horvath DJ, Gao S, Fukamachi K, Karimov JH. Development of a circulatory mock loop for biventricular device testing with various heart conditions. Int J Artif Organs 2020; 43:600-605. [PMID: 32013672 DOI: 10.1177/0391398820903316] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This study aimed to evaluate a newly designed circulatory mock loop intended to model cardiac and circulatory hemodynamics for mechanical circulatory support device testing. The mock loop was built with dedicated ports suitable for attaching assist devices in various configurations. This biventricular mock loop uses two pneumatic pumps (Abiomed AB5000™, Danvers, MA, USA) driven by a dual-output driver (Thoratec Model 2600, Pleasanton, CA, USA). The drive pressures can be individually modified to simulate a healthy heart and left and/or right heart failure conditions, and variable compliance and fluid volume allow for additional customization. The loop output for a healthy heart was tested at 4.2 L/min with left and right atrial pressures of 1 and 5 mm Hg, respectively; a mean aortic pressure of 93 mm Hg; and pulmonary artery pressure of 17 mm Hg. Under conditions of left heart failure, these values were reduced to 2.1 L/min output, left atrial pressure = 28 mm Hg, right atrial pressure = 3 mm Hg, aortic pressure = 58 mm Hg, and pulmonary artery pressure = 35 mm Hg. Right heart failure resulted in the reverse balance: left atrial pressure = 0 mm Hg, right atrial pressure = 30 mm Hg, aortic pressure = 100 mm Hg, and pulmonary artery pressure = 13 mm Hg with a flow of 3.9 L/min. For biventricular heart failure, flow was decreased to 1.6 L/min, left atrial pressure = 13 mm Hg, right atrial pressure = 13 mm Hg, aortic pressure = 52 mm Hg, and pulmonary artery pressure = 18 mm Hg. This mock loop could become a reliable bench tool to simulate a range of heart failure conditions.
Collapse
Affiliation(s)
- Yuichiro Kado
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Takuma Miyamoto
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - David J Horvath
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA.,R1 Engineering LLC, Euclid, OH, USA
| | - Shengqiang Gao
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA.,Medical Device Solutions, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Jamshid H Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|
21
|
Simulated Performance of the Cleveland Clinic Continuous-Flow Total Artificial Heart Using the Virtual Mock Loop. ASAIO J 2018; 65:565-572. [PMID: 30074965 DOI: 10.1097/mat.0000000000000857] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Our new Virtual Mock Loop (VML) is a mathematical model designed to simulate the human cardiovascular system and gauge performance of mechanical circulatory support devices. We aimed to mimic the hemodynamic performance of Cleveland Clinic's self-regulating continuous-flow total artificial heart (CFTAH) via VML and evaluate VML's accuracy versus bench data from our standard mock circulatory loop. The VML reproduced 23 hemodynamic conditions. Systemic/pulmonary vascular resistances and pump rotational speed were set for VML from bench test data. We compared outputs (pump flow, left/right pump pressure rise, normalized pump performance, and atrial pressure difference) of the two methods. Data from pump flow and left pump pressure rise were similar, but right pump pressure rise slightly differed. Left pump normalized pump performance curves were similar. Right pump VML results were within the same performance range indicated by bench tests. The plots of atrial pressure differences of VML versus bench-test data were similar, but slightly differed in the midrange of systemic/pulmonary gradients. Virtual Mock Loop successfully reproduced results from our mock circulatory loop of CFTAH test conditions. The CFTAH's self-regulation feature of right pump performance was also calculated effectively. We foresee using versions of the VML for training, simulating physiologic cardiac conditions, and patient monitoring.
Collapse
|
22
|
Fukamachi K, Karimov JH, Horvath DJ, Sunagawa G, Byram NA, Kuban BD, Moazami N. Initial in vitro testing of a paediatric continuous-flow total artificial heart. Interact Cardiovasc Thorac Surg 2018; 26:897-901. [PMID: 29365118 PMCID: PMC10903986 DOI: 10.1093/icvts/ivx429] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2017] [Accepted: 12/10/2017] [Indexed: 12/03/2023] Open
Abstract
OBJECTIVES Mechanical circulatory support has become standard therapy for adult patients with end-stage heart failure; however, in paediatric patients with congenital heart disease, the options for chronic mechanical circulatory support are limited to paracorporeal devices or off-label use of devices intended for implantation in adults. Congenital heart disease and cardiomyopathy often involve both the left and right ventricles; in such cases, heart transplantation, a biventricular assist device or a total artificial heart is needed to adequately sustain both pulmonary and systemic circulations. We aimed to evaluate the in vitro performance of the initial prototype of our paediatric continuous-flow total artificial heart. METHODS The paediatric continuous-flow total artificial heart pump was downsized from the adult continuous-flow total artificial heart configuration by a scale factor of 0.70 (1/3 of total volume) to enable implantation in infants. System performance of this prototype was evaluated using the continuous-flow total artificial heart mock loop set to mimic paediatric circulation. We generated maps of pump performance and atrial pressure differences over a wide range of systemic vascular resistance/pulmonary vascular resistance and pump speeds. RESULTS Performance data indicated left pump flow range of 0.4-4.7 l/min at 100 mmHg delta pressure. The left/right atrial pressure difference was maintained within ±5 mmHg with systemic vascular resistance/pulmonary vascular resistance ratios between 1.4 and 35, with/without pump speed modulation, verifying expected passive self-regulation of atrial pressure balance. CONCLUSIONS The paediatric continuous-flow total artificial heart prototype met design requirements for self-regulation and performance; in vivo pump performance studies are ongoing.
Collapse
Affiliation(s)
- Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Jamshid H Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | | | - Gengo Sunagawa
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Nicole A Byram
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Barry D Kuban
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
- Medical Device Solutions (Electronics Core), Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Nader Moazami
- Department of Thoracic and Cardiovascular Surgery, Kaufman Center for Heart Failure, Miller Family Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|
23
|
Fukamachi K, Karimov JH, Byram NA, Sunagawa G, Dessoffy R, Miyamoto T, Horvath DJ. Anatomical study of the Cleveland Clinic continuous-flow total artificial heart in adult and pediatric configurations. J Artif Organs 2018; 21:383-386. [DOI: 10.1007/s10047-018-1039-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2017] [Accepted: 03/27/2018] [Indexed: 12/21/2022]
|
24
|
Karimov JH, Horvath DJ, Byram N, Sunagawa G, Kuban BD, Gao S, Dessoffy R, Fukamachi K. Early in vivo experience with the pediatric continuous-flow total artificial heart. J Heart Lung Transplant 2018; 37:1029-1034. [PMID: 29703578 DOI: 10.1016/j.healun.2018.03.019] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2017] [Revised: 03/14/2018] [Accepted: 03/28/2018] [Indexed: 12/29/2022] Open
Abstract
BACKGROUND Heart transplantation in infants and children is an accepted therapy for end-stage heart failure, but donor organ availability is low and always uncertain. Mechanical circulatory support is another standard option, but there is a lack of intracorporeal devices due to size and functional range. The purpose of this study was to evaluate the in vivo performance of our initial prototype of a pediatric continuous-flow total artificial heart (P-CFTAH), comprising a dual pump with one motor and one rotating assembly, supported by a hydrodynamic bearing. METHODS In acute studies, the P-CFTAH was implanted in 4 lambs (average weight: 28.7 ± 2.3 kg) via a median sternotomy under cardiopulmonary bypass. Pulmonary and systemic pump performance parameters were recorded. RESULTS The experiments showed good anatomical fit and easy implantation, with an average aortic cross-clamp time of 98 ± 18 minutes. Baseline hemodynamics were stable in all 4 animals (pump speed: 3.4 ± 0.2 krpm; pump flow: 2.1 ± 0.9 liters/min; power: 3.0 ± 0.8 W; arterial pressure: 68 ± 10 mm Hg; left and right atrial pressures: 6 ± 1 mm Hg, for both). Any differences between left and right atrial pressures were maintained within the intended limit of ±5 mm Hg over a wide range of ratios of systemic-to-pulmonary vascular resistance (0.7 to 12), with and without pump-speed modulation. Pump-speed modulation was successfully performed to create arterial pulsation. CONCLUSION This initial P-CFTAH prototype met the proposed requirements for self-regulation, performance, and pulse modulation.
Collapse
Affiliation(s)
- Jamshid H Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | | | - Nicole Byram
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Gengo Sunagawa
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Barry D Kuban
- Medical Device Solutions, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Shengqiang Gao
- Medical Device Solutions, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Raymond Dessoffy
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA.
| |
Collapse
|
25
|
Abstract
Control of mechanical circulatory support pump output typically requires that pressure-regulating functions be accomplished by active control of the speed or geometry of the device, with feedback from pressure or flow sensors. This article presents a different design approach, with a pressure-regulating device as the core design feature, allowing the essential control function of regulating pressure to be directly programmed into the hydromechanical design. We show the step-by-step transformation of a pressure-regulating device into a continuous-flow total artificial heart that passively balances left and right circulations without the need for pressure and flow sensors. In addition, we discuss a ventricular assist device that prevents backflow in the event of power interruption and also dynamically interacts with residual ventricle function to preserve pulsatility.
Collapse
|
26
|
Sensor-Based Physiologic Control Strategy for Biventricular Support with Rotary Blood Pumps. ASAIO J 2017; 64:338-350. [PMID: 28938308 DOI: 10.1097/mat.0000000000000671] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022] Open
Abstract
Rotary biventricular assist devices (BiVAD) are becoming a clinically accepted treatment option for end-stage biventricular failure. To improve BiVAD efficacy and safety, we propose a control algorithm to achieve the clinical objectives of maintaining left-right-sided balance, restoring physiologic flows, and preventing ventricular suction. The control algorithm consists of two proportional-integral (PI) controllers for left and right ventricular assist devices (LVAD and RVAD) to maintain differential pump pressure across LVAD (ΔPL) and RVAD (ΔPR) to provide left-right balance and physiologic flow. To prevent ventricular suction, LVAD and RVAD pump speed differentials (ΔRPML, ΔRPMR) were maintained above user-defined thresholds. Efficacy and robustness of the proposed algorithm were tested in silico for axial and centrifugal flow BiVAD using 1) normal and excessive ΔPL and/or ΔPR setpoints, 2) rapid threefold increase in pulmonary vascular or vena caval resistances, 3) transient responses from exercise to rest, and 4) ventricular fibrillation. The study successfully demonstrated that the proposed BiVAD algorithm achieved the clinical objectives but required pressure sensors to continuously measure ΔPL and ΔPR. The proposed control algorithm is device independent, should not require any modifications to the pump or inflow/outflow cannulae/grafts, and may be directly applied to current rotary blood pumps for biventricular support.
Collapse
|
27
|
Karimov JH, Gao S, Dessoffy R, Sunagawa G, Sinkewich M, Grady P, Sale S, Moazami N, Fukamachi K. Novel technique for airless connection of artificial heart to vascular conduits. J Artif Organs 2017; 20:386-389. [PMID: 28761992 DOI: 10.1007/s10047-017-0976-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Accepted: 07/24/2017] [Indexed: 11/29/2022]
Abstract
Successful implantation of a total artificial heart relies on multiple standardized procedures, primarily the resection of the native heart, and exacting preparation of the atrial and vascular conduits for pump implant and activation. Achieving secure pump connections to inflow/outflow conduits is critical to a successful outcome. During the connection process, however, air may be introduced into the circulation, traveling to the brain and multiple organs. Such air emboli block blood flow to these areas and are detrimental to long-term survival. A correctly managed pump-to-conduit connection prevents air from collecting in the pump and conduits. To further optimize pump-connection techniques, we have developed a novel connecting sleeve that enables airless connection of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) to the conduits. In this brief report, we describe the connecting sleeve design and our initial results from two acute in vivo implantations using a scaled-down version of the CFTAH.
Collapse
Affiliation(s)
- Jamshid H Karimov
- Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
| | - Shengqiang Gao
- Medical Device Solutions, Cleveland Clinic, Cleveland, OH, USA
| | - Raymond Dessoffy
- Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - Gengo Sunagawa
- Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - Martin Sinkewich
- Perfusion Services, Miller Family Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Patrick Grady
- Perfusion Services, Miller Family Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Shiva Sale
- Department of Cardiothoracic Anesthesiology, Anesthesiology Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Nader Moazami
- Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.,Department of Thoracic and Cardiovascular Surgery, Kaufman Center for Heart Failure, Cardiac Transplantation and Mechanical Circulatory Support, Miller Family Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
| |
Collapse
|
28
|
Glynn J, Song H, Hull B, Withers S, Gelow J, Mudd J, Starr A, Wampler R. The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop. Artif Organs 2017; 41:904-910. [DOI: 10.1111/aor.12959] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2016] [Revised: 02/17/2017] [Accepted: 03/31/2017] [Indexed: 11/27/2022]
Affiliation(s)
- Jeremy Glynn
- Biomedical Engineering; OregonHeart, Inc.; Roseville CA USA
| | - Howard Song
- Cardiothoracic Surgery; Oregon Health & Science University; Portland OR USA
| | - Bryan Hull
- Biomedical Engineering; OregonHeart, Inc.; Roseville CA USA
| | | | - Jill Gelow
- Cardiology; Oregon Health & Science University; Portland OR USA
| | - James Mudd
- Cardiology; Oregon Health & Science University; Portland OR USA
| | - Albert Starr
- Cardiothoracic Surgery; Oregon Health & Science University; Portland OR USA
| | - Richard Wampler
- Cardiothoracic Surgery; Oregon Health & Science University; Portland OR USA
| |
Collapse
|
29
|
Horvath D, Byram N, Karimov JH, Kuban B, Sunagawa G, Golding LAR, Moazami N, Fukamachi K. Mechanism of Self-Regulation and In Vivo Performance of the Cleveland Clinic Continuous-Flow Total Artificial Heart. Artif Organs 2017; 41:411-417. [PMID: 27401215 DOI: 10.1111/aor.12780] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2015] [Revised: 03/11/2016] [Accepted: 05/10/2016] [Indexed: 01/20/2023]
Abstract
Cleveland Clinic's continuous-flow total artificial heart (CFTAH) provides systemic and pulmonary circulations using one assembly (one motor, two impellers). The right pump hydraulic output to the pulmonary circulation is self-regulated by the rotating assembly's passive axial movement in response to atrial differential pressure to balance itself to the left pump output. This combination of features integrates a biocompatible, pressure-balancing regulator with a double-ended pump. The CFTAH requires no flow or pressure sensors. The only control parameter is pump speed, modulated at programmable rates (60-120 beats/min) and amplitudes (0 to ±25%) to provide flow pulses. In bench studies, passive self-regulation (range: -5 mm Hg ≤ [left atrial pressure - right atrial pressure] ≤ 10 mm Hg) was demonstrated over a systemic/vascular resistance ratio range of 2.0-20 and a flow range of 3-9 L/min. Performance of the most recent pump configuration was demonstrated in chronic studies, including three consecutive long-term experiments (30, 90, and 90 days). These experiments were performed at a constant postoperative mean speed with a ±15% speed modulation, demonstrating a totally self-regulating mode of operation, from 3 days after implant to explant, despite a weight gain of up to 40%. The mechanism of self-regulation functioned properly, continuously throughout the chronic in vivo experiments, demonstrating the performance goals.
Collapse
Affiliation(s)
- David Horvath
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic
| | - Nicole Byram
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic
| | - Jamshid H Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic
| | - Barry Kuban
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic
| | - Gengo Sunagawa
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic
| | - Leonard A R Golding
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic
| | - Nader Moazami
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic
- Department of Thoracic and Cardiovascular Surgery, Kaufman Center for Heart Failure, Cardiac Transplantation and Mechanical Circulatory Support, Miller Family Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic
| |
Collapse
|
30
|
Fukamachi K, Karimov JH, Sunagawa G, Horvath DJ, Byram N, Kuban BD, Dessoffy R, Sale S, Golding LAR, Moazami N. Generating pulsatility by pump speed modulation with continuous-flow total artificial heart in awake calves. J Artif Organs 2017; 20:381-385. [PMID: 28391521 DOI: 10.1007/s10047-017-0958-5] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2016] [Accepted: 03/27/2017] [Indexed: 11/27/2022]
Abstract
The purpose of this study was to evaluate the effects of sinusoidal pump speed modulation of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) on hemodynamics and pump flow in an awake chronic calf model. The sinusoidal pump speed modulations, performed on the day of elective sacrifice, were set at ±15 and ± 25% of mean pump speed at 80 bpm in four awake calves with a CFTAH. The systemic and pulmonary arterial pulse pressures increased to 12.0 and 12.3 mmHg (±15% modulation) and to 15.9 and 15.7 mmHg (±25% modulation), respectively. The pulsatility index and surplus hemodynamic energy significantly increased, respectively, to 1.05 and 1346 ergs/cm at ±15% speed modulation and to 1.51 and 3381 ergs/cm at ±25% speed modulation. This study showed that it is feasible to generate pressure pulsatility with pump speed modulation; the platform is suitable for evaluating the physiologic impact of pulsatility and allows determination of the best speed modulations in terms of magnitude, frequency, and profiles.
Collapse
Affiliation(s)
- Kiyotaka Fukamachi
- Cardiovascular Dynamics Laboratory, Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
| | - Jamshid H Karimov
- Cardiovascular Dynamics Laboratory, Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
| | - Gengo Sunagawa
- Cardiovascular Dynamics Laboratory, Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - David J Horvath
- Cardiovascular Dynamics Laboratory, Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
- R1 Engineering, Cleveland, OH, USA
| | - Nicole Byram
- Cardiovascular Dynamics Laboratory, Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - Barry D Kuban
- Electronics Core, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Raymond Dessoffy
- Cardiovascular Dynamics Laboratory, Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - Shiva Sale
- Department of Cardiothoracic Anesthesiology, Anesthesiology Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Leonard A R Golding
- Cardiovascular Dynamics Laboratory, Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - Nader Moazami
- Cardiovascular Dynamics Laboratory, Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
- Department of Thoracic and Cardiovascular Surgery, Kaufman Center for Heart Failure, Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA
| |
Collapse
|
31
|
Karimov JH, Grady P, Sinkewich M, Sunagawa G, Dessoffy R, Byram N, Moazami N, Fukamachi K. Moderate hypothermia technique for chronic implantation of a total artificial heart in calves. J Artif Organs 2017; 20:182-185. [PMID: 28238150 DOI: 10.1007/s10047-017-0946-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2016] [Accepted: 01/17/2017] [Indexed: 10/20/2022]
Abstract
The benefit of whole-body hypothermia in preventing ischemic injury during cardiac surgical operations is well documented. However, application of hypothermia during in vivo total artificial heart implantation has not become widespread because of limited understanding of the proper techniques and restrictions implied by constitutional and physiological characteristics specific to each animal model. Similarly, the literature on hypothermic set-up in total artificial heart implantation has also been limited. Herein we present our experience using hypothermia in bovine models implanted with the Cleveland Clinic continuous-flow total artificial heart.
Collapse
Affiliation(s)
- Jamshid H Karimov
- Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
| | - Patrick Grady
- Perfusion Services, Cardiac Surgery, Cleveland Clinic, Cleveland, OH, USA
| | - Martin Sinkewich
- Perfusion Services, Cardiac Surgery, Cleveland Clinic, Cleveland, OH, USA
| | - Gengo Sunagawa
- Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - Raymond Dessoffy
- Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - Nicole Byram
- Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA
| | - Nader Moazami
- Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.,Department of Thoracic and Cardiovascular Surgery, Kaufman Center for Heart Failure, Heart and Vascular Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering/ND20, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH, 44195, USA.
| |
Collapse
|
32
|
In vitro performance investigation of SynCardia™ Freedom® driver via patient simulator mock loop. Int J Artif Organs 2016; 39:502-508. [PMID: 27768204 DOI: 10.5301/ijao.5000524] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/22/2016] [Indexed: 12/31/2022]
Abstract
PURPOSE The gold standard therapy for patients with advanced heart failure is heart transplant. The gap between donors and patients in waiting lists promoted the development of circulatory support devices, such as the total artificial heart (TAH). Focusing on in vitro tests performed with CardioWest™ TAH (CW) driven by the SynCardia Freedom® portable driver (FD) the present study goals are: i) prove the reliability of a hydraulic circuit used as patient simulator to replicate a quasi-physiological scenario for various hydrodynamic conditions, ii) investigate the hydrodynamic performance of the CW FD, iii) help clinicians in possible interpretation of clinical cases outcomes. METHODS In vitro tests were performed using a mechanic-hydraulic patient simulator. Cardiac output (CO), CW ventricles filling, atrial, ventricles, aortic and pulmonary artery pressures were measured for different values of vascular resistance in both systemic (SVR) and pulmonary (PVR) physiological range. RESULTS After increasing the PVR, the left atrial pressure decreased according to the expected physiological trend, while aortic pressure remained almost stable, proving the ability of the simulator to mimic a physiological scenario. Unexpectedly, the mean pulmonary artery pressure (PPA) was found to increase above 30 mmHg in the range of physiological PVR (2.6 WU) and for constant CO. CONCLUSIONS The increase in PPA is probably associated with the pre-set driving setup of the FD. The finding suggests a possible explanation of the clinical course of a patient who experienced complications soon after being supported by the FD, with the occurrence of dyspnea and pulmonary edema despite a high cardiac index.
Collapse
|
33
|
Goerlich CE, Frazier OH, Cohn WE. Previous challenges and current progress–the use of total artificial hearts in patients with end-stage heart failure. Expert Rev Cardiovasc Ther 2016; 14:1095-8. [DOI: 10.1080/14779072.2016.1217154] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
34
|
Sensorless Suction Recognition in the Self-Regulating Cleveland Clinic Continuous-Flow Total Artificial Heart. ASAIO J 2016; 61:726-8. [PMID: 26102177 DOI: 10.1097/mat.0000000000000263] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
The Cleveland Clinic continuous-flow total artificial heart passively regulates itself in regard to the relative performance of systemic and pulmonary pumps. The system incorporates real-time monitoring to detect any indication of incipient left or right suction as input for automatic controller response. To recognize suction, the external controller compares the waveforms of modulating speed input and power feedback. Deviations in periodic waveforms indicate sudden changes to flow impedance, which are characteristic of suction events as the pump speed is modulating. Incipient suction is indicated within 3 seconds of being detected in the power wave form, allowing timely controller response before mean flow is affected. This article describes the results obtained from subjecting the system to severe hemodynamic manipulation during an acute study in a calf.
Collapse
|
35
|
Abstract
Implantation of mechanical circulatory support devices is challenging, especially in patients with a small chest cavity. We evaluated how well the Cleveland Clinic continuous-flow total artificial heart (CFTAH) fit the anatomy of patients about to receive a heart transplant. A mock pump model of the CFTAH was rapid-prototyped using biocompatible materials. The model was brought to the operative table, and the direction, length, and angulation of the inflow/outflow ports and outflow conduits were evaluated after the recipient's ventricles had been resected. Thoracic cavity measurements were based on preoperative computed tomographic data. The CFTAH fit well in all five patients (height, 170 ± 9 cm; weight, 75 ± 24 kg). Body surface area was 1.9 ± 0.3 m (range, 1.6-2.1 m). The required inflow and outflow port orientation of both the left and right housings appeared consistent with the current version of the CFTAH implanted in calves. The left outflow conduit remained straight, but the right outflow direction necessitated a 73 ± 22 degree angulation to prevent potential kinking when crossing over the connected left outflow. These data support the fact that our design achieves the proper anatomical relationship of the CFTAH to a patient's native vessels.
Collapse
|
36
|
Sunagawa G, Horvath DJ, Karimov JH, Moazami N, Fukamachi K. Future Prospects for the Total Artificial Heart. Expert Rev Med Devices 2016; 13:191-201. [PMID: 26732059 DOI: 10.1586/17434440.2016.1136212] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
A total artificial heart (TAH) is the sole remaining option for patients with biventricular failure who cannot be rescued by left ventricular assist devices (LVADs) alone. However, the pulsatile TAH in clinical use today has limitations: large pump size, unknown durability, required complex anticoagulation regimen, and association with significant postsurgical complications. That pump is noisy; its large pneumatic driving lines traverse the body, with bulky external components for its drivers. Continuous-flow pumps, which caused a paradigm shift in the LVAD field, have already contributed to the rapidly evolving development of TAHs. Novel continuous-flow TAHs are only in preclinical testing or developmental stages. We here review the current state of TAHs, with recommended requirements for the TAH of the future.
Collapse
Affiliation(s)
- Gengo Sunagawa
- a Department of Biomedical Engineering , Lerner Research Institute, Cleveland Clinic , Cleveland , OH , USA
| | - David J Horvath
- a Department of Biomedical Engineering , Lerner Research Institute, Cleveland Clinic , Cleveland , OH , USA
| | - Jamshid H Karimov
- a Department of Biomedical Engineering , Lerner Research Institute, Cleveland Clinic , Cleveland , OH , USA
| | - Nader Moazami
- a Department of Biomedical Engineering , Lerner Research Institute, Cleveland Clinic , Cleveland , OH , USA.,b Department of Thoracic and Cardiovascular Surgery, Kaufman Center for Heart Failure, Cardiac Transplantation and Mechanical Circulatory Support, Miller Family Heart and Vascular Institute , Cleveland Clinic , Cleveland , OH , USA
| | - Kiyotaka Fukamachi
- a Department of Biomedical Engineering , Lerner Research Institute, Cleveland Clinic , Cleveland , OH , USA
| |
Collapse
|
37
|
Prospects for Development of Technologies for Complete Replacement of Heart Function by Mechanical Circulatory Support Systems. BIOMEDICAL ENGINEERING 2016. [DOI: 10.1007/s10527-016-9544-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
38
|
Gregory SD, Stevens MC, Pauls JP, Schummy E, Diab S, Thomson B, Anderson B, Tansley G, Salamonsen R, Fraser JF, Timms D. In Vivo Evaluation of Active and Passive Physiological Control Systems for Rotary Left and Right Ventricular Assist Devices. Artif Organs 2016; 40:894-903. [PMID: 26748566 DOI: 10.1111/aor.12654] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Preventing ventricular suction and venous congestion through balancing flow rates and circulatory volumes with dual rotary ventricular assist devices (VADs) configured for biventricular support is clinically challenging due to their low preload and high afterload sensitivities relative to the natural heart. This study presents the in vivo evaluation of several physiological control systems, which aim to prevent ventricular suction and venous congestion. The control systems included a sensor-based, master/slave (MS) controller that altered left and right VAD speed based on pressure and flow; a sensor-less compliant inflow cannula (IC), which altered inlet resistance and, therefore, pump flow based on preload; a sensor-less compliant outflow cannula (OC) on the right VAD, which altered outlet resistance and thus pump flow based on afterload; and a combined controller, which incorporated the MS controller, compliant IC, and compliant OC. Each control system was evaluated in vivo under step increases in systemic (SVR ∼1400-2400 dyne/s/cm(5) ) and pulmonary (PVR ∼200-1000 dyne/s/cm(5) ) vascular resistances in four sheep supported by dual rotary VADs in a biventricular assist configuration. Constant speed support was also evaluated for comparison and resulted in suction events during all resistance increases and pulmonary congestion during SVR increases. The MS controller reduced suction events and prevented congestion through an initial sharp reduction in pump flow followed by a gradual return to baseline (5.0 L/min). The compliant IC prevented suction events; however, reduced pump flows and pulmonary congestion were noted during the SVR increase. The compliant OC maintained pump flow close to baseline (5.0 L/min) and prevented suction and congestion during PVR increases. The combined controller responded similarly to the MS controller to prevent suction and congestion events in all cases while providing a backup system in the event of single controller failure.
Collapse
Affiliation(s)
- Shaun D Gregory
- School of Medicine, University of Queensland, Brisbane, Queensland, Australia. .,Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia.
| | - Michael C Stevens
- Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia.,School of Information Technology and Electrical Engineering, University of Queensland, Brisbane, Queensland, Australia
| | - Jo P Pauls
- Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia.,School of Engineering, Griffith University, Southport, Queensland, Australia
| | - Emma Schummy
- Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia
| | - Sara Diab
- School of Medicine, University of Queensland, Brisbane, Queensland, Australia.,Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia
| | - Bruce Thomson
- Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia
| | - Ben Anderson
- Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia
| | - Geoff Tansley
- Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia.,School of Engineering, Griffith University, Southport, Queensland, Australia
| | - Robert Salamonsen
- Department of Epidemiology and Preventative Medicine, Monash University, Melbourne, Victoria, Australia.,Intensive Care Unit, Alfred Hospital, Melbourne, Victoria, Australia
| | - John F Fraser
- School of Medicine, University of Queensland, Brisbane, Queensland, Australia.,Innovative Cardiovascular Engineering and Technology Laboratory, Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia
| | | |
Collapse
|
39
|
Feng J, Cohn WE, Parnis SM, Sodha NR, Clements RT, Sellke N, Frazier OH, Sellke FW. New continuous-flow total artificial heart and vascular permeability. J Surg Res 2015; 199:296-305. [PMID: 26188957 PMCID: PMC4636951 DOI: 10.1016/j.jss.2015.06.035] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2015] [Revised: 06/03/2015] [Accepted: 06/12/2015] [Indexed: 11/19/2022]
Abstract
BACKGROUND We tested the short-term effects of completely nonpulsatile versus pulsatile circulation after ventricular excision and replacement with total implantable pumps in an animal model on peripheral vascular permeability. METHODS Ten calves underwent cardiac replacement with two HeartMate III continuous-flow rotary pumps. In five calves, the pump speed was rapidly modulated to impart a low-frequency pulse pressure in the physiologic range (10-25 mm Hg) at a rate of 40 pulses per minute (PP). The remaining five calves were supported with a pulseless systemic circulation and no modulation of pump speed (NP). Skeletal muscle biopsies were obtained before cardiac replacement (baseline) and on postoperative days (PODs) 1, 7, and 14. Skeletal muscle-tissue water content was measured, and morphologic alterations of skeletal muscle were assessed. VE-cadherin, phospho-VE-cadherin, and CD31 were analyzed by immunohistochemistry. RESULTS There were no significant changes in tissue water content and skeletal muscle morphology within group or between groups at baseline, PODs 1, 7, and 14, respectively. There were no significant alterations in the expression and/or distribution of VE-cadherin, phospho-VE-cadherin, and CD31 in skeletal muscle vasculature at baseline, PODs 1, 7, and 14 within each group or between the two groups, respectively. Although continuous-flow total artificial heart (CFTAH) with or without a pulse pressure caused slight increase in tissue water content and histologic damage scores at PODs 7 and 14, it failed to reach statistical significance. CONCLUSIONS There was no significant adherens-junction protein degradation and phosphorylation in calf skeletal muscle microvasculature after CFTAH implantation, suggesting that short term of CFTAH with or without pulse pressure did not cause peripheral endothelial injury and did not increase the peripheral microvascular permeability.
Collapse
Affiliation(s)
- Jun Feng
- Division of Cardiothoracic Surgery, Department of Surgery, Cardiovascular Research Center, Rhode Island Hospital, Alpert Medical School of Brown University, Providence, Rhode Island
| | - William E Cohn
- Cardiovascular Research Laboratories, Department of Surgery, Texas Heart Institute at St. Luke's Episcopal Hospital, Houston, Texas
| | - Steven M Parnis
- Cardiovascular Research Laboratories, Department of Surgery, Texas Heart Institute at St. Luke's Episcopal Hospital, Houston, Texas
| | - Neel R Sodha
- Division of Cardiothoracic Surgery, Department of Surgery, Cardiovascular Research Center, Rhode Island Hospital, Alpert Medical School of Brown University, Providence, Rhode Island
| | - Richard T Clements
- Division of Cardiothoracic Surgery, Department of Surgery, Cardiovascular Research Center, Rhode Island Hospital, Alpert Medical School of Brown University, Providence, Rhode Island
| | - Nicholas Sellke
- Division of Cardiothoracic Surgery, Department of Surgery, Cardiovascular Research Center, Rhode Island Hospital, Alpert Medical School of Brown University, Providence, Rhode Island
| | - O Howard Frazier
- Cardiovascular Research Laboratories, Department of Surgery, Texas Heart Institute at St. Luke's Episcopal Hospital, Houston, Texas
| | - Frank W Sellke
- Division of Cardiothoracic Surgery, Department of Surgery, Cardiovascular Research Center, Rhode Island Hospital, Alpert Medical School of Brown University, Providence, Rhode Island.
| |
Collapse
|
40
|
Fox CS, McKenna KL, Allaire PE, Mentzer RM, Throckmorton AL. Total Artificial Hearts-Past, Current, and Future. J Card Surg 2015; 30:856-64. [DOI: 10.1111/jocs.12644] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Carson S. Fox
- From the BioCirc Research Laboratory; School of Biomedical Engineering; Science and Health Systems; Drexel University; Philadelphia Pennsylvania
| | - Kelli L. McKenna
- From the BioCirc Research Laboratory; School of Biomedical Engineering; Science and Health Systems; Drexel University; Philadelphia Pennsylvania
| | - Paul E. Allaire
- Rotor Bearing Solutions International; Charlottesville Virginia
| | - Robert M. Mentzer
- Division of Cardiobiology; Cedars-Sinai Heart Institute; Cedars-Sinai Medical Center; Los Angeles California
- Wayne State University School of Medicine; Detroit Michigan
| | - Amy L. Throckmorton
- From the BioCirc Research Laboratory; School of Biomedical Engineering; Science and Health Systems; Drexel University; Philadelphia Pennsylvania
| |
Collapse
|
41
|
Double-wire sternal closure technique in bovine animal models for total artificial heart implant. Int J Artif Organs 2015; 38:465-7. [PMID: 26349531 DOI: 10.5301/ijao.5000426] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/27/2015] [Indexed: 11/20/2022]
Abstract
In vivo preclinical testing of mechanical circulatory devices requires large animal models that provide reliable physiological and hemodynamic conditions by which to test the device and investigate design and development strategies. Large bovine species are commonly used for mechanical circulatory support device research. The animals used for chronic in vivo support require high-quality care and excellent surgical techniques as well as advanced methods of postoperative care. These techniques are constantly being updated and new methods are emerging.We report results of our double steel-wire closure technique in large bovine models used for Cleveland Clinic's continuous-flow total artificial heart development program. This is the first report of double-wire sternal fixation used in large bovine models.
Collapse
|
42
|
Anatomy of the bovine ascending aorta and brachiocephalic artery found unfavorable for total artificial heart implant. J Artif Organs 2015; 18:358-60. [PMID: 26105105 DOI: 10.1007/s10047-015-0849-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2014] [Accepted: 06/16/2015] [Indexed: 10/23/2022]
Abstract
The biocompatibility assessment of the Cleveland Clinic continuous-flow total artificial heart is an important part of the device developmental program. Surgical and postoperative management are key factors in achieving optimal outcomes. However, the presence of vascular anatomical abnormalities in experimental animal models is often unpredictable and may worsen the expected outcomes. We report a technical impediment encountered during total artificial heart implantation complicated by unfavorable bovine anatomy of the ascending aorta and brachiocephalic arterial trunk.
Collapse
|
43
|
Karimov JH, Moazami N, Kobayashi M, Sale S, Such K, Byram N, Sunagawa G, Horvath D, Gao S, Kuban B, Golding LAR, Fukamachi K. First report of 90-day support of 2 calves with a continuous-flow total artificial heart. J Thorac Cardiovasc Surg 2015; 150:687-93.e1. [PMID: 26173607 DOI: 10.1016/j.jtcvs.2015.06.023] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/02/2015] [Revised: 05/13/2015] [Accepted: 06/04/2015] [Indexed: 02/07/2023]
Abstract
OBJECTIVE The Cleveland Clinic continuous-flow total artificial heart (CFTAH) is a compact, single-piece, valveless, pulsatile pump providing self-regulated hemodynamic output to left/right circulation. We evaluated chronic in vivo pump performance, physiologic and hemodynamic parameters, and biocompatibility of the CFTAH in a well-established calf model. METHODS CFTAH pumps have been implanted in 17 calves total. Hemodynamic parameters, pump performance, and device-related adverse events were evaluated during studies and at necropsy. RESULTS In vivo experiments demonstrated good hemodynamic performance (pump flow, 7.3 ± 0.7 L/min; left atrial pressure, 16 ± 3 mm Hg; right atrial pressure, 17 ± 3 mm Hg; right atrial pressure-left atrial pressure difference, 1 ± 2 mm Hg; mean arterial pressure, 103 ± 7 mm Hg; arterial pulse pressure, 30 ± 11 mm Hg; and pulmonary arterial pressure, 34 ± 5 mm Hg). The CFTAH has operated within design specifications and never failed. With ever-improving pump design, the implants have shown no chronic hemolysis. Three animals with recent CFTAH implantation recovered well, with no postoperative anticoagulation, during planned in vivo durations of 30, 90, and 90 days (last 2 were intended to be 90-day studies). All these longest-surviving cases showed good biocompatibility, with no thromboembolism in organs. CONCLUSIONS The current CFTAH has demonstrated reliable self-regulation of hemodynamic output and acceptable biocompatibility without anticoagulation throughout 90 days of chronic implantation in calves. Meeting these milestones is in accord with our strategy to achieve transfer of this unique technology to human surgical practice, thus filling the urgent need for cardiac replacement devices as destination therapy.
Collapse
Affiliation(s)
- Jamshid H Karimov
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Nader Moazami
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio; Department of Thoracic and Cardiovascular Surgery, Kaufman Center for Heart Failure, Cardiac Transplantation and Mechanical Circulatory Support, Miller Family Heart and Vascular Institute, Cleveland Clinic, Cleveland, Ohio
| | - Mariko Kobayashi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Shiva Sale
- Department of Cardiothoracic Anesthesiology, Anesthesiology Institute, Cleveland Clinic, Cleveland, Ohio
| | - Kimberly Such
- Biological Resources Unit, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Nicole Byram
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Gengo Sunagawa
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - David Horvath
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Shengqiang Gao
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Barry Kuban
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Leonard A R Golding
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio
| | - Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio.
| |
Collapse
|
44
|
|
45
|
Ishii K, Hosoda K, Nishida M, Isoyama T, Saito I, Ariyoshi K, Inoue Y, Ono T, Nakagawa H, Sato M, Hara S, Lee X, Wu SY, Imachi K, Abe Y. Hydrodynamic characteristics of the helical flow pump. J Artif Organs 2015; 18:206-12. [PMID: 25784463 DOI: 10.1007/s10047-015-0828-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Accepted: 03/05/2015] [Indexed: 11/27/2022]
Abstract
The helical flow pump (HFP) was invented to be an ideal pump for developing the TAH and the helical flow TAH (HFTAH) using two HFPs has been developed. However, since the HFP is quite a new pump, hydrodynamic characteristics inside the pump are not clarified. To analyze hydrodynamic characteristics of the HFP, flow visualization study using the particle image velocimetry and computational fluid dynamics analysis were performed. The experimental and computational models were developed to simulate the left HFP of the HFTAH and distributions of flow velocity vectors, shear stress and pressure inside the pump were examined. In distribution of flow velocity vectors, the vortexes in the vane were observed, which indicated that the HFP has a novel and quite unique working principle in which centrifugal force rotates the fluid in the helical volutes and the fluid is transferred from the inlet to the outlet helical volutes according to the helical structure. In distribution of shear stress, the highest shear stress that was considered to be occurred by the shunt flow across the impeller was found around the entrance of the inlet helical volute. However, it was not so high to cause hemolysis. This shunt flow is thought to be improved by redesigning the inlet and outlet helical volutes. In distribution of pressure, negative pressure was found near the entrance of the inlet helical volute. However, it was not high. Negative pressure is thought to be reduced with an improvement in the design of the impeller or the vane shape.
Collapse
Affiliation(s)
- Kohei Ishii
- Department of Biomedical Engineering, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan,
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
46
|
Gregory SD, Schummy E, Pearcy M, Pauls JP, Tansley G, Fraser JF, Timms D. A compliant, banded outflow cannula for decreased afterload sensitivity of rotary right ventricular assist devices. Artif Organs 2014; 39:102-9. [PMID: 25041754 DOI: 10.1111/aor.12338] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Biventricular support with dual rotary ventricular assist devices (VADs) has been implemented clinically with restriction of the right VAD (RVAD) outflow cannula to artificially increase afterload and, therefore, operate within recommended design speed ranges. However, the low preload and high afterload sensitivity of these devices increase the susceptibility of suction events. Active control systems are prone to sensor drift or inaccurate inferred (sensor-less) data, therefore an alternative solution may be of benefit. This study presents the in vitro evaluation of a compliant outflow cannula designed to passively decrease the afterload sensitivity of rotary RVADs and minimize left-sided suction events. A one-way fluid-structure interaction model was initially used to produce a design with suitable flow dynamics and radial deformation. The resultant geometry was cast with different initial cross-sectional restrictions and concentrations of a softening diluent before evaluation in a mock circulation loop. Pulmonary vascular resistance (PVR) was increased from 50 dyne s/cm(5) until left-sided suction events occurred with each compliant cannula and a rigid, 4.5 mm diameter outflow cannula for comparison. Early suction events (PVR ∼ 300 dyne s/cm(5) ) were observed with the rigid outflow cannula. Addition of the compliant section with an initial 3 mm diameter restriction and 10% diluent expanded the outflow restriction as PVR increased, thus increasing RVAD flow rate and preventing left-sided suction events at PVR levels beyond 1000 dyne s/cm(5) . Therefore, the compliant, restricted outflow cannula provided a passive control system to assist in the prevention of suction events with rotary biventricular support while maintaining pump speeds within normal ranges of operation.
Collapse
Affiliation(s)
- Shaun D Gregory
- School of Medicine, University of Queensland, Brisbane, Queensland, Australia; Innovative Cardiovascular Engineering and Technology Laboratory, The Prince Charles Hospital, Brisbane, Queensland, Australia; Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia
| | | | | | | | | | | | | |
Collapse
|
47
|
Design and Evaluation of a Hybrid Mock Circulatory Loop for total Artificial Heart Testing. Int J Artif Organs 2014; 37:71-80. [DOI: 10.5301/ijao.5000301] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/26/2013] [Indexed: 11/20/2022]
Abstract
Aims A hybrid mock circulatory loop (MCL) was developed for total artificial heart (TAH) performance evaluation. The hybrid MCL consists of hydraulic hardware components and a software computer model. Design The hydraulic components are divided into the systemic and pulmonary circulation, each of which includes electrically controlled compliances, resistors, and a venous volume which can be adjusted for a wide range of physiological and pathological conditions. The software model simulates the baroreflex autoregulatory response by automatically adjusting the hydraulic parameters according to changes of condition in the MCL. Results The experimental results demonstrated a good representation of the human cardiovascular system and the capability of real-time variation of physiological and pathological conditions. The functionality of the baroreflex autoregulatory mechanism was evaluated by simulation of a postural change. Conclusions The hybrid MCL that we developed allows variable and continuous in vitro evaluation of mechanical circulatory support devices in TAH configuration and particularly their control algorithms in response to various cardiovascular conditions. The system has been built in a modular configuration to allow testing of different types of devices and thus provides a valuable test platform prior to animal experiments.
Collapse
|
48
|
|
49
|
Hosoda K, Ishii K, Isoyama T, Saito I, Inoue Y, Ariyoshi K, Ono T, Nakagawa H, Imachi K, Kumagai H, Abe Y. Computational fluid dynamics analysis of the pump parameters in the helical flow pump. J Artif Organs 2013; 17:9-15. [PMID: 24318404 DOI: 10.1007/s10047-013-0739-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2013] [Accepted: 10/27/2013] [Indexed: 11/29/2022]
Abstract
The helical flow pump (HFP) was invented to develop a total artificial heart at the University of Tokyo in 2005. The HFP consists of the multi-vane impeller involving rotor magnets, a motor stator and pump housing having double-helical volutes. To investigate the characteristics of the HFP, computational fluid dynamics analysis was performed. Validation of the computational model was performed with the data of the actual pump. A control computational model in which the vane area corresponded approximately to that of the actual pump was designed for the parametric study. The parametric study was performed varying the vane height, vane width and helical volute pitch. When the vane height was varied from 0.5 to 1.5 times that of the control computational model, the H-Q (pressure head vs. flow) and efficiency curves were translated in parallel with the vane height. When the vane height was two and three times that of the control computational model, the profile of these curves changed. From the results, the best proportion for the vane was considered to be a vane height between 1.5 and 2 times the vane width. The effect of vane width was not very strong compared to that of the vane height. A similar tendency in vane height was observed by varying the helical volute pitch. The best helical volute-pitch size is considered to be between 1.5 and 2 times the vane width. Although further study is necessary to determine the best values for these parameters, the characteristics of the pump parameters in the HFP could be approximately clarified.
Collapse
Affiliation(s)
- Kyohei Hosoda
- Department of Biomedical Engineering, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Abe Y, Ishii K, Isoyama T, Saito I, Inoue Y, Sato M, Hara S, Hosoda K, Ariyoshi K, Nakagawa H, Ono T, Fukazawa K, Ishihara K, Imachi K. The helical flow total artificial heart: implantation in goats. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2013:2720-3. [PMID: 24110289 DOI: 10.1109/embc.2013.6610102] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
To realize a total artificial heart (TAH) with high performance, high durability, good anatomical fitting, and good blood compatibility, the helical flow TAH (HFTAH) has been developed with two helical flow pumps having hydrodynamic levitation impeller. The HFTAH was implanted in goats to investigate its anatomical fitting, blood compatibility, mechanical stability, control stability, and so on. The size of the HFTAH was designed to be 80 mm in diameter and 84 mm wide. The maximum output was 19 L/min against 100 mmHg of pressure head. Eight adult female goats weighting from 45 to 56.3 kg (average 49.7 kg) were used. Under the extracorporeal circulation, natural heart was removed at the atrioventricular groove and the HFTAH was implanted. The HFTAH was driven with a pulsatile mode. The 1/R control was applied when the right atrial pressure recovered. The HFTAH could be implanted with good anatomical fitting in all goats. Two goats survived for more than a week. One goat is ongoing. Other goats did not survive for more than two days with various reasons. In the goats that survived for more than a week, the hydrodynamic bearing was worn and broken, which indicated that the bearing touched to the shaft. The cause was supposed to be the influence of the sucking effect. The potential of the HFTAH could be demonstrated with this study. The stability of the hydrodynamic bearing in a living body, especially the influence of the sucking effect, was considered to be very important and a further study should be necessary.
Collapse
|