Suzukawa M, Ohta K, Sugimoto M, Ohshima N, Kobayashi N, Tashimo H, Tanimoto Y, Itano J, Kimura G, Takata S, Nakano T, Yamashita T, Ikegame S, Hyodo K, Abe M, Chibana K, Kamide Y, Sasaki K, Hashimoto H. Identification of exhaled volatile organic compounds that characterize asthma phenotypes: A J-VOCSA study. Allergol Int 2024:S1323-8930(24)00047-9. [PMID: 38658257 DOI: 10.1016/j.alit.2024.04.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 03/23/2024] [Accepted: 04/03/2024] [Indexed: 04/26/2024] Open
Abstract
BACKGROUND Asthma is characterized by phenotypes of different clinical, demographic, and pathological characteristics. Identifying the profile of exhaled volatile organic compounds (VOCs) in asthma phenotypes may facilitate establishing biomarkers and understanding asthma background pathogenesis. This study aimed to identify exhaled VOCs that characterize severe asthma phenotypes among patients with asthma. METHODS This was a multicenter cross-sectional study of patients with severe asthma in Japan. Clinical data were obtained from medical records, and questionnaires were collected. Exhaled breath was sampled and subjected to thermal desorption gas chromatography-mass spectrometry (GC/MS). RESULTS Using the decision tree established in the previous nationwide asthma cohort study, 245 patients with asthma were divided into five phenotypes and subjected to exhaled VOC analysis with 50 healthy controls (HCs). GC/MS detected 243 VOCs in exhaled breath samples, and 142 frequently detected VOCs (50% of all samples) were used for statistical analyses. Cluster analysis assigning the groups with similar VOC profile patterns showed the highest similarities between phenotypes 3 and 4 (early-onset asthma phenotypes), followed by the similarities between phenotypes 1 and 2 (late-onset asthma phenotypes). Comparisons between phenotypes 1-5 and HC revealed 19 VOCs, in which only methanesulfonic anhydride showed p < 0.05 adjusted by false discovery rate (FDR). Comparison of these phenotypes yielded several VOCs showing different trends (p < 0.05); however, no VOCs showed p < 0.05 adjusted by FDR. CONCLUSIONS Exhaled VOC profiles may be useful for distinguishing asthma and asthma phenotypes; however, these findings need to be validated, and their pathological roles should be clarified.
Collapse
Affiliation(s)
- Maho Suzukawa
- Clinical Research Center, National Hospital Organization Tokyo National Hospital, Tokyo, Japan.
| | - Ken Ohta
- Clinical Research Center, National Hospital Organization Tokyo National Hospital, Tokyo, Japan; Japan Anti-Tuberculosis Association, JATA Fukujuji Hospital, Tokyo, Japan.
| | - Masahiro Sugimoto
- Institute for Advanced Biosciences, Keio University, Yamagata, Japan; Human Metabolome Technologies, Inc., Yamagata, Japan
| | - Nobuharu Ohshima
- Clinical Research Center, National Hospital Organization Tokyo National Hospital, Tokyo, Japan
| | - Nobuyuki Kobayashi
- Clinical Research Center, National Hospital Organization Tokyo National Hospital, Tokyo, Japan
| | - Hiroyuki Tashimo
- Clinical Research Center, National Hospital Organization Tokyo National Hospital, Tokyo, Japan
| | - Yasushi Tanimoto
- National Hospital Organization Minami-Okayama Medical Center, Okayama, Japan
| | - Junko Itano
- National Hospital Organization Minami-Okayama Medical Center, Okayama, Japan
| | - Goro Kimura
- National Hospital Organization Minami-Okayama Medical Center, Okayama, Japan
| | - Shohei Takata
- National Hospital Organization Fukuokahigashi Medical Center, Fukuoka, Japan
| | - Takako Nakano
- National Hospital Organization Fukuokahigashi Medical Center, Fukuoka, Japan
| | - Takafumi Yamashita
- National Hospital Organization Fukuokahigashi Medical Center, Fukuoka, Japan
| | - Satoshi Ikegame
- National Hospital Organization Fukuokahigashi Medical Center, Fukuoka, Japan
| | - Kentaro Hyodo
- National Hospital Organization Ibarakihigashi National Hospital, Ibaraki, Japan
| | - Masahiro Abe
- National Hospital Organization Ehime Medical Center, Ehime, Japan
| | - Kenji Chibana
- National Hospital Organization Okinawa National Hospital, Okinawa, Japan
| | - Yosuke Kamide
- National Hospital Organization Sagamihara National Hospital, Kanagawa, Japan
| | - Kazunori Sasaki
- Institute for Advanced Biosciences, Keio University, Yamagata, Japan; Human Metabolome Technologies, Inc., Yamagata, Japan
| | - Hiroya Hashimoto
- National Hospital Organization Nagoya Medical Center, Nagoya, Japan
| |
Collapse
|
2
|
Martínez-Moral MP, Tena MT, Martín-Carnicero A, Martínez A. Highly sensitive serum volatolomic biomarkers for pancreatic cancer diagnosis. Clin Chim Acta 2024; 557:117895. [PMID: 38561063 DOI: 10.1016/j.cca.2024.117895] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 03/04/2024] [Accepted: 03/29/2024] [Indexed: 04/04/2024]
Abstract
The discovery of new diagnostic tools for the early detection of diseases with poor prognosis such as pancreatic adenocarcinoma (PAC) is of high importance. The results from a control-case study (20 PAC patients, 19 healthy controls) for the search of new biomarkers of pancreatic cancer based in differences in the serum volatolome are presented in this work. Volatolomics were performed following a non-targeted HS-SPME-GC/MS approach, and a total of 433 volatile organic compounds (VOCs) was detected in the human serum samples. Of these, 125 VOC indexes showed a significant variation when controls and patients were compared (p-value < 0.05). Bonferroni corrected p-values < 0.05 were found for 40 features. PCA analysis showed the control-PAC discrimination capability of VOCs in serum, and PLS-DA was performed to select the best candidate biomarkers for the diagnosis of PAC. For the 40 selected VOCs, calculated areas under the curve (AUC) ranged from 0.98 to 0.85, and 11 of them were successfully validated using an independent set of samples (5 PAC patients, 5 healthy controls). Four of the proposed PAC biomarkers were identified as toluene, 2-ethyl-1-hexanol, pentylbenzene, and butoxymethylbenzene. Combinations of the identified PAC biomarkers were tested and showed AUC > 0.90, with the more promising candidate being butoxymethylbenzene (AUC = 0.98).
Collapse
Affiliation(s)
- María-Pilar Martínez-Moral
- Oncology Area, Center for Biomedical Research of La Rioja (CIBIR), C/ Piqueras 98, 26006 Logroño, Spain; Department of Chemistry, University of La Rioja, C/ Madre de Dios 51, 26006 Logroño, Spain.
| | - María Teresa Tena
- Department of Chemistry, University of La Rioja, C/ Madre de Dios 51, 26006 Logroño, Spain.
| | - Alfonso Martín-Carnicero
- Oncology Area, Center for Biomedical Research of La Rioja (CIBIR), C/ Piqueras 98, 26006 Logroño, Spain; Medical Oncology Department, Hospital San Pedro, C/Piqueras 98, 26006 Logroño, Spain.
| | - Alfredo Martínez
- Oncology Area, Center for Biomedical Research of La Rioja (CIBIR), C/ Piqueras 98, 26006 Logroño, Spain.
| |
Collapse
|
3
|
Angioli R, Santonico M, Pennazza G, Montera R, Luvero D, Gatti A, Zompanti A, Finamore P, Incalzi RA. Use of Sensor Array Analysis to Detect Ovarian Cancer through Breath, Urine, and Blood: A Case-Control Study. Diagnostics (Basel) 2024; 14:561. [PMID: 38473033 DOI: 10.3390/diagnostics14050561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 02/26/2024] [Accepted: 02/27/2024] [Indexed: 03/14/2024] Open
Abstract
Ovarian cancer (OC) is the eighth most common cancer in women. Since screening programs do not exist, it is often diagnosed in advanced stages. Today, the detection of OC is based on clinical examination, transvaginal ultrasound (US), and serum biomarker (Carbohydrate Antigen 125 (CA 125) and Human Epididymis Protein 4 (HE4)) dosage, with a sensitivity of 88% and 95%, respectively, and a specificity of 84% for US and 76% for biomarkers. These methods are clearly not enough, and OC in its early stages is often missed. Many scientists have recently focused their attention on volatile organic compounds (VOCs). These are gaseous molecules, found in the breath, that could provide interesting information on several diseases, including solid tumors. To detect VOCs, an electronic nose was invented by a group of researchers. A similar device, the e-tongue, was later created to detect specific molecules in liquids. For the first time in the literature, we investigated the potential use of the electronic nose and the electronic tongue to detect ovarian cancer not just from breath but also from urine, blood, and plasma samples.
Collapse
Affiliation(s)
- Roberto Angioli
- Unit of Gynecology, University Campus Bio-Medico of Rome, Via Alvaro del Portillo 200, 00128 Rome, Italy
| | - Marco Santonico
- Unit of Electronics for Sensor Systems, Department of Science and Technology for Sustainable Development and One Health, University Campus Bio-Medico of Rome, Via Alvaro del Portillo 21, 00128 Rome, Italy
| | - Giorgio Pennazza
- Unit of Electronics for Sensor Systems, Department of Engineering, University Campus Bio-Medico of Rome, Via Alvaro del Portillo 21, 00128 Rome, Italy
| | - Roberto Montera
- Unit of Gynecology, University Campus Bio-Medico of Rome, Via Alvaro del Portillo 200, 00128 Rome, Italy
| | - Daniela Luvero
- Unit of Gynecology, University Campus Bio-Medico of Rome, Via Alvaro del Portillo 200, 00128 Rome, Italy
| | - Alessandra Gatti
- Unit of Gynecology, University Campus Bio-Medico of Rome, Via Alvaro del Portillo 200, 00128 Rome, Italy
| | - Alessandro Zompanti
- Unit of Electronics for Sensor Systems, Department of Engineering, University Campus Bio-Medico of Rome, Via Alvaro del Portillo 21, 00128 Rome, Italy
| | - Panaiotis Finamore
- Unit of Geriatrics, University Campus Bio-Medico of Rome, Via Alvaro del Portillo 200, 00128 Rome, Italy
| | - Raffaele Antonelli Incalzi
- Unit of Geriatrics, University Campus Bio-Medico of Rome, Via Alvaro del Portillo 200, 00128 Rome, Italy
| |
Collapse
|
4
|
Seidl E, Licht JC, de Vries R, Ratjen F, Grasemann H. Exhaled Breath Analysis Detects the Clearance of Staphylococcus aureus from the Airways of Children with Cystic Fibrosis. Biomedicines 2024; 12:431. [PMID: 38398033 PMCID: PMC10887307 DOI: 10.3390/biomedicines12020431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2024] [Revised: 02/09/2024] [Accepted: 02/12/2024] [Indexed: 02/25/2024] Open
Abstract
BACKGROUND Electronic nose (eNose) technology can be used to characterize volatile organic compound (VOC) mixes in breath. While previous reports have shown that eNose can detect lung infections with pathogens such as Staphylococcus aureus (SA) in people with cystic fibrosis (CF), the clinical utility of eNose for longitudinally monitoring SA infection status is unknown. METHODS In this longitudinal study, a cloud-connected eNose, the SpiroNose, was used for the breath profile analysis of children with CF at two stable visits and compared based on changes in SA infection status between visits. Data analysis involved advanced sensor signal processing, ambient correction, and statistics based on the comparison of breath profiles between baseline and follow-up visits. RESULTS Seventy-two children with CF, with a mean (IQR) age of 13.8 (9.8-16.4) years, were studied. In those with SA-positive airway cultures at baseline but SA-negative cultures at follow-up (n = 19), significant signal differences were detected between Baseline and Follow-up at three distinct eNose sensors, i.e., S4 (p = 0.047), S6 (p = 0.014), and S7 (p = 0.014). Sensor signal changes with the clearance of SA from airways were unrelated to antibiotic treatment. No changes in sensor signals were seen in patients with unchanged infection status between visits. CONCLUSIONS Our results demonstrate the potential applicability of the eNose as a non-invasive clinical tool to longitudinally monitor pulmonary SA infection status in children with CF.
Collapse
Affiliation(s)
- Elias Seidl
- Division of Respiratory Medicine, Department of Pediatrics, The Hospital for Sick Children, Toronto, ON M5G 1X8, Canada; (E.S.); (J.-C.L.); (F.R.)
- Division of Respiratory Medicine, University Children’s Hospital Zurich, 8032 Zurich, Switzerland
| | - Johann-Christoph Licht
- Division of Respiratory Medicine, Department of Pediatrics, The Hospital for Sick Children, Toronto, ON M5G 1X8, Canada; (E.S.); (J.-C.L.); (F.R.)
| | - Rianne de Vries
- Breathomix BV, Bargelaan 200, 2333 CW Leiden, The Netherlands;
| | - Felix Ratjen
- Division of Respiratory Medicine, Department of Pediatrics, The Hospital for Sick Children, Toronto, ON M5G 1X8, Canada; (E.S.); (J.-C.L.); (F.R.)
- Translational Medicine Program, Research Institute, The Hospital for Sick Children, University of Toronto, Toronto, ON M5G 1X8, Canada
| | - Hartmut Grasemann
- Division of Respiratory Medicine, Department of Pediatrics, The Hospital for Sick Children, Toronto, ON M5G 1X8, Canada; (E.S.); (J.-C.L.); (F.R.)
- Translational Medicine Program, Research Institute, The Hospital for Sick Children, University of Toronto, Toronto, ON M5G 1X8, Canada
| |
Collapse
|
5
|
Brener S, Snitz K, Sobel N. An electronic nose can identify humans by the smell of their ear. Chem Senses 2024; 49:bjad053. [PMID: 38237638 PMCID: PMC10810274 DOI: 10.1093/chemse/bjad053] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2023] [Indexed: 01/27/2024] Open
Abstract
Terrestrial mammals identify conspecifics by body odor. Dogs can also identify humans by body odor, and in some instances, humans can identify other humans by body odor as well. Despite the potential for a powerful biometric tool, smell has not been systematically used for this purpose. A question arising in the application of smell to biometrics is which bodily odor source should we measure. Breath is an obvious candidate, but the associated humidity can challenge many sensing devices. The armpit is also a candidate source, but it is often doused in cosmetics. Here, we test the hypothesis that the ear may provide an effective source for odor-based biometrics. The inside of the ear has relatively constant humidity, cosmetics are not typically applied inside the ear, and critically, ears contain cerumen, a potent source of volatiles. We used an electronic nose to identify 12 individuals within and across days, using samples from the armpit, lower back, and ear. In an identification setting where chance was 8.33% (1 of 12), we found that we could identify a person by the smell of their ear within a day at up to ~87% accuracy (~10 of 12, binomial P < 10-5), and across days at up to ~22% accuracy (~3 of 12, binomial P < 0.012). We conclude that humans can indeed be identified from the smell of their ear, but the results did not imply a consistent advantage over other bodily odor sources.
Collapse
Affiliation(s)
- Stephanie Brener
- The Azrieli National Center for Human Brain Imaging and Research, Weizmann Institute of Science, Rehovot 7610001, Israel
- The Department for Brain Sciences, Weizmann Institute of Science, Rehovot 7610001, Israel
| | - Kobi Snitz
- The Azrieli National Center for Human Brain Imaging and Research, Weizmann Institute of Science, Rehovot 7610001, Israel
- The Department for Brain Sciences, Weizmann Institute of Science, Rehovot 7610001, Israel
| | - Noam Sobel
- The Azrieli National Center for Human Brain Imaging and Research, Weizmann Institute of Science, Rehovot 7610001, Israel
- The Department for Brain Sciences, Weizmann Institute of Science, Rehovot 7610001, Israel
| |
Collapse
|
6
|
Jia Z, Thavasi V, Venkatesan T, Lee P. Breath Analysis for Lung Cancer Early Detection-A Clinical Study. Metabolites 2023; 13:1197. [PMID: 38132879 PMCID: PMC10745549 DOI: 10.3390/metabo13121197] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 11/30/2023] [Accepted: 12/06/2023] [Indexed: 12/23/2023] Open
Abstract
This clinical study presents a comprehensive investigation into the utility of breath analysis as a non-invasive method for the early detection of lung cancer. The study enrolled 14 lung cancer patients, 14 non-lung cancer controls with diverse medical conditions, and 3 tuberculosis (TB) patients for biomarker discovery. Matching criteria including age, gender, smoking history, and comorbidities were strictly followed to ensure reliable comparisons. A systematic breath sampling protocol utilizing a BIO-VOC sampler was employed, followed by VOC analysis using Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC/MS). The resulting VOC profiles were subjected to stringent statistical analysis, including Orthogonal Projections to Latent Structures-Discriminant Analysis (OPLS-DA), Kruskal-Wallis test, and Receiver Operating Characteristic (ROC) analysis. Notably, 13 VOCs exhibited statistically significant differences between lung cancer patients and controls. The combination of eight VOCs (hexanal, heptanal, octanal, benzaldehyde, undecane, phenylacetaldehyde, decanal, and benzoic acid) demonstrated substantial discriminatory power with an area under the curve (AUC) of 0.85, a sensitivity of 82%, and a specificity of 76% in the discovery set. Validation in an independent cohort yielded an AUC of 0.78, a sensitivity of 78%, and a specificity of 64%. Further analysis revealed that elevated aldehyde levels in lung cancer patients' breath could be attributed to overactivated Alcohol Dehydrogenase (ADH) pathways in cancerous tissues. Addressing methodological challenges, this study employed a matching of physiological and pathological confounders, controlled room air samples, and standardized breath sampling techniques. Despite the limitations, this study's findings emphasize the potential of breath analysis as a diagnostic tool for lung cancer and suggest its utility in differentiating tuberculosis from lung cancer. However, further research and validation are warranted for the translation of these findings into clinical practice.
Collapse
Affiliation(s)
- Zhunan Jia
- NUSNNI-Nanocore, National University of Singapore, Singapore 117411, Singapore;
| | - Velmurugan Thavasi
- Center for Quantum Research and Technology, Homer L. Dodge Department of Physics and Astronomy, University of Oklahoma, Norman, OK 73019, USA;
| | - Thirumalai Venkatesan
- NUSNNI-Nanocore, National University of Singapore, Singapore 117411, Singapore;
- Center for Quantum Research and Technology, Homer L. Dodge Department of Physics and Astronomy, University of Oklahoma, Norman, OK 73019, USA;
| | - Pyng Lee
- Respiratory and Critical Care Medicine, National University Hospital, 1E Kent Ridge Road, Singapore 119228, Singapore
| |
Collapse
|
7
|
Glöckler J, Mizaikoff B, Díaz de León-Martínez L. SARS CoV-2 infection screening via the exhaled breath fingerprint obtained by FTIR spectroscopic gas-phase analysis. A proof of concept. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 302:123066. [PMID: 37356392 PMCID: PMC10286574 DOI: 10.1016/j.saa.2023.123066] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 05/30/2023] [Accepted: 06/20/2023] [Indexed: 06/27/2023]
Abstract
The COVID-19 pandemic remains a global challenge now with the long-COVID arising. Mitigation measures focused on case counting, assessment and determination of variants and their likely targets of infection and transmission, the pursuit of drug treatments, use and enhancement of masks, social distancing, vaccination, post-infection rehabilitation, and mass screening. The latter is of utmost importance given the current scenario of infections, reinfections, and long-term health effects. Research on screening platforms has been developed to provide more sensitive, specific, and reliable tests that are accessible to the entire population and can be used to assess the prognosis of the disease as well as the subsequent health follow-up of patients with sequelae of COVID-19. Therefore, the aim of the present study was the simulation of exhaled breath of COVID-19 patients by evaluation of three identified COVID-19 indicator breath biomarkers (acetone (ACE), acetaldehyde (ACH) and nitric oxide (NO)) by gas-phase infrared spectroscopy as a proof-of-concept principle for the detection of infected patients' exhaled breath fingerprint and subsequent follow-up. The specific fingerprints of each of the compounds and the overall fingerprint were obtained. The synthetic exhaled breath evaluation concept revealed a linearity of r = 0.99 for all compounds, and LODs of 6.42, 13.81, 9.22 ppm, and LOQs of 42.26, 52.57, 69.23 ppm for NO, ACE, and ACH, respectively. This study proves the fundamental feasibility of gas-phase infrared spectroscopy for fingerprinting lung damage biomarkers in exhaled breath of patients with COVID-19. This analysis would allow faster and cheaper screening and follow-up of infected individuals, which could improve mass screening in POC settings.
Collapse
Affiliation(s)
- Johannes Glöckler
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany
| | - Boris Mizaikoff
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany; Hahn-Schickard Institute for Microanalysis Systems, Sedanstrasse 14, 89077 Ulm, Germany
| | - Lorena Díaz de León-Martínez
- Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081 Ulm, Germany.
| |
Collapse
|
8
|
Savito L, Scarlata S, Bikov A, Carratù P, Carpagnano GE, Dragonieri S. Exhaled volatile organic compounds for diagnosis and monitoring of asthma. World J Clin Cases 2023; 11:4996-5013. [PMID: 37583852 PMCID: PMC10424019 DOI: 10.12998/wjcc.v11.i21.4996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 06/08/2023] [Accepted: 07/06/2023] [Indexed: 07/26/2023] Open
Abstract
The asthmatic inflammatory process results in the generation of volatile organic compounds (VOCs), which are subsequently secreted by the airways. The study of these elements through gas chromatography-mass spectrometry (GC-MS), which can identify individual molecules with a discriminatory capacity of over 85%, and electronic-Nose (e-NOSE), which is able to perform a quick onboard pattern-recognition analysis of VOCs, has allowed new prospects for non-invasive analysis of the disease in an "omics" approach. In this review, we aim to collect and compare the progress made in VOCs analysis using the two methods and their instrumental characteristics. Studies have described the potential of GC-MS and e-NOSE in a multitude of relevant aspects of the disease in both children and adults, as well as differential diagnosis between asthma and other conditions such as wheezing, cystic fibrosis, COPD, allergic rhinitis and last but not least, the accuracy of these methods compared to other diagnostic tools such as lung function, FeNO and eosinophil count. Due to significant limitations of both methods, it is still necessary to improve and standardize techniques. Currently, e-NOSE appears to be the most promising aid in clinical practice, whereas GC-MS, as the gold standard for the structural analysis of molecules, remains an essential tool in terms of research for further studies on the pathophysiologic pathways of the asthmatic inflammatory process. In conclusion, the study of VOCs through GC-MS and e-NOSE appears to hold promise for the non-invasive diagnosis, assessment, and monitoring of asthma, as well as for further research studies on the disease.
Collapse
Affiliation(s)
- Luisa Savito
- Department of Internal Medicine, Unit of Respiratory Pathophysiology and Thoracic Endoscopy, Fondazione Policlinico Universitario Campus Bio Medico, Rome 00128, Italy
| | - Simone Scarlata
- Department of Internal Medicine, Unit of Respiratory Pathophysiology and Thoracic Endoscopy, Fondazione Policlinico Universitario Campus Bio Medico, Rome 00128, Italy
| | - Andras Bikov
- Wythenshawe Hospital, Manchester University NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester M13 9WL, United Kingdom
- Division of Infection, Immunity and Respiratory Medicine, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PT, United Kingdom
| | - Pierluigi Carratù
- Department of Internal Medicine "A.Murri", University of Bari "Aldo Moro", Bari 70124, Italy
| | | | - Silvano Dragonieri
- Department of Respiratory Diseases, University of Bari, Bari 70124, Italy
| |
Collapse
|
9
|
Shahbazi Khamas S, Alizadeh Bahmani AH, Vijverberg SJ, Brinkman P, Maitland-van der Zee AH. Exhaled volatile organic compounds associated with risk factors for obstructive pulmonary diseases: a systematic review. ERJ Open Res 2023; 9:00143-2023. [PMID: 37650089 PMCID: PMC10463028 DOI: 10.1183/23120541.00143-2023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 04/21/2023] [Indexed: 09/01/2023] Open
Abstract
Background Asthma and COPD are among the most common respiratory diseases. To improve the early detection of exacerbations and the clinical course of asthma and COPD new biomarkers are needed. The development of noninvasive metabolomics of exhaled air into a point-of-care tool is an appealing option. However, risk factors for obstructive pulmonary diseases can potentially introduce confounding markers due to altered volatile organic compound (VOC) patterns being linked to these risk factors instead of the disease. We conducted a systematic review and presented a comprehensive list of VOCs associated with these risk factors. Methods A PRISMA-oriented systematic search was conducted across PubMed, Embase and Cochrane Libraries between 2000 and 2022. Full-length studies evaluating VOCs in exhaled breath were included. A narrative synthesis of the data was conducted, and the Newcastle-Ottawa Scale was used to assess the quality of included studies. Results The search yielded 2209 records and, based on the inclusion/exclusion criteria, 24 articles were included in the qualitative synthesis. In total, 232 individual VOCs associated with risk factors for obstructive pulmonary diseases were found; 58 compounds were reported more than once and 12 were reported as potential markers of asthma and/or COPD in other studies. Critical appraisal found that the identified studies were methodologically heterogeneous and had a variable risk of bias. Conclusion We identified a series of exhaled VOCs associated with risk factors for asthma and/or COPD. Identification of these VOCs is necessary for the further development of exhaled metabolites-based point-of-care tests in these obstructive pulmonary diseases.
Collapse
Affiliation(s)
- Shahriyar Shahbazi Khamas
- Department of Pulmonary Medicine, Amsterdam UMC location, University of Amsterdam, Amsterdam, the Netherlands
- Amsterdam Institute for Infection and Immunity, Amsterdam, the Netherlands
- Amsterdam Public Health, Amsterdam, the Netherlands
| | - Amir Hossein Alizadeh Bahmani
- Department of Pulmonary Medicine, Amsterdam UMC location, University of Amsterdam, Amsterdam, the Netherlands
- Amsterdam Institute for Infection and Immunity, Amsterdam, the Netherlands
- Amsterdam Public Health, Amsterdam, the Netherlands
| | - Susanne J.H. Vijverberg
- Department of Pulmonary Medicine, Amsterdam UMC location, University of Amsterdam, Amsterdam, the Netherlands
- Amsterdam Institute for Infection and Immunity, Amsterdam, the Netherlands
- Amsterdam Public Health, Amsterdam, the Netherlands
| | - Paul Brinkman
- Department of Pulmonary Medicine, Amsterdam UMC location, University of Amsterdam, Amsterdam, the Netherlands
- Amsterdam Institute for Infection and Immunity, Amsterdam, the Netherlands
- Amsterdam Public Health, Amsterdam, the Netherlands
- These authors contributed equally
| | - Anke H. Maitland-van der Zee
- Department of Pulmonary Medicine, Amsterdam UMC location, University of Amsterdam, Amsterdam, the Netherlands
- Amsterdam Institute for Infection and Immunity, Amsterdam, the Netherlands
- Amsterdam Public Health, Amsterdam, the Netherlands
- These authors contributed equally
| |
Collapse
|
10
|
Sharma A, Kumar R, Varadwaj P. Smelling the Disease: Diagnostic Potential of Breath Analysis. Mol Diagn Ther 2023; 27:321-347. [PMID: 36729362 PMCID: PMC9893210 DOI: 10.1007/s40291-023-00640-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/11/2023] [Indexed: 02/03/2023]
Abstract
Breath analysis is a relatively recent field of research with much promise in scientific and clinical studies. Breath contains endogenously produced volatile organic components (VOCs) resulting from metabolites of ingested precursors, gut and air-passage bacteria, environmental contacts, etc. Numerous recent studies have suggested changes in breath composition during the course of many diseases, and breath analysis may lead to the diagnosis of such diseases. Therefore, it is important to identify the disease-specific variations in the concentration of breath to diagnose the diseases. In this review, we explore methods that are used to detect VOCs in laboratory settings, VOC constituents in exhaled air and other body fluids (e.g., sweat, saliva, skin, urine, blood, fecal matter, vaginal secretions, etc.), VOC identification in various diseases, and recently developed electronic (E)-nose-based sensors to detect VOCs. Identifying such VOCs and applying them as disease-specific biomarkers to obtain accurate, reproducible, and fast disease diagnosis could serve as an alternative to traditional invasive diagnosis methods. However, the success of VOC-based identification of diseases is limited to laboratory settings. Large-scale clinical data are warranted for establishing the robustness of disease diagnosis. Also, to identify specific VOCs associated with illness states, extensive clinical trials must be performed using both analytical instruments and electronic noses equipped with stable and precise sensors.
Collapse
Affiliation(s)
- Anju Sharma
- Systems Biology Lab, Indian Institute of Information Technology, Allahabad, Uttar Pradesh, India
| | - Rajnish Kumar
- Amity Institute of Biotechnology, Amity University Uttar Pradesh, Uttar Pradesh, Lucknow Campus, Lucknow, India
| | - Pritish Varadwaj
- Systems Biology Lab, Indian Institute of Information Technology, Allahabad, Uttar Pradesh, India.
| |
Collapse
|
11
|
Sas V, Cherecheș-Panța P, Borcau D, Schnell CN, Ichim EG, Iacob D, Coblișan AP, Drugan T, Man SC. Breath Prints for Diagnosing Asthma in Children. J Clin Med 2023; 12:jcm12082831. [PMID: 37109167 PMCID: PMC10146639 DOI: 10.3390/jcm12082831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2023] [Revised: 04/04/2023] [Accepted: 04/10/2023] [Indexed: 04/29/2023] Open
Abstract
Electronic nose (e-nose) is a new technology applied for the identification of volatile organic compounds (VOC) in breath air. Measuring VOC in exhaled breath can adequately identify airway inflammation, especially in asthma. Its noninvasive character makes e-nose an attractive technology applicable in pediatrics. We hypothesized that an electronic nose could discriminate the breath prints of patients with asthma from controls. A cross-sectional study was conducted and included 35 pediatric patients. Eleven cases and seven controls formed the two training models (models A and B). Another nine cases and eight controls formed the external validation group. Exhaled breath samples were analyzed using Cyranose 320, Smith Detections, Pasadena, CA, USA. The discriminative ability of breath prints was investigated by principal component analysis (PCA) and canonical discriminative analysis (CDA). Cross-validation accuracy (CVA) was calculated. For the external validation step, accuracy, sensitivity and specificity were calculated. Duplicate sampling of exhaled breath was obtained for ten patients. E-nose was able to discriminate between the controls and asthmatic patient group with a CVA of 63.63% and an M-distance of 3.13 for model A and a CVA of 90% and an M-distance of 5.55 for model B in the internal validation step. In the second step of external validation, accuracy, sensitivity and specificity were 64%, 77% and 50%, respectively, for model A, and 58%, 66% and 50%, respectively, for model B. Between paired breath sample fingerprints, there were no significant differences. An electronic nose can discriminate pediatric patients with asthma from controls, but the accuracy obtained in the external validation was lower than the CVA obtained in the internal validation step.
Collapse
Affiliation(s)
- Valentina Sas
- Department of Pediatrics, "Iuliu Hațieganu" University of Medicine and Pharmacy Cluj-Napoca, 400124 Cluj-Napoca, Romania
- Clinical Hospital for Pediatric Emergencies, 400124 Cluj-Napoca, Romania
| | - Paraschiva Cherecheș-Panța
- Department of Pediatrics, "Iuliu Hațieganu" University of Medicine and Pharmacy Cluj-Napoca, 400124 Cluj-Napoca, Romania
- Clinical Hospital for Pediatric Emergencies, 400124 Cluj-Napoca, Romania
| | - Diana Borcau
- Clinical Hospital for Pediatric Emergencies, 400124 Cluj-Napoca, Romania
| | - Cristina-Nicoleta Schnell
- Department of Pediatrics, "Iuliu Hațieganu" University of Medicine and Pharmacy Cluj-Napoca, 400124 Cluj-Napoca, Romania
- Clinical Hospital for Pediatric Emergencies, 400124 Cluj-Napoca, Romania
| | - Edita-Gabriela Ichim
- Department of Pediatrics, "Iuliu Hațieganu" University of Medicine and Pharmacy Cluj-Napoca, 400124 Cluj-Napoca, Romania
- Clinical Hospital for Pediatric Emergencies, 400124 Cluj-Napoca, Romania
| | - Daniela Iacob
- Department of Pediatrics, "Iuliu Hațieganu" University of Medicine and Pharmacy Cluj-Napoca, 400124 Cluj-Napoca, Romania
- Clinical Hospital for Pediatric Emergencies, 400124 Cluj-Napoca, Romania
| | - Alina-Petronela Coblișan
- Clinical Hospital for Pediatric Emergencies, 400124 Cluj-Napoca, Romania
- Department of Nursing, "Iuliu Hațieganu" University of Medicine and Pharmacy Cluj-Napoca, 400124 Cluj-Napoca, Romania
| | - Tudor Drugan
- Department of Medical Informatics and Biostatistics, "Iuliu Hațieganu" University of Medicine and Pharmacy Cluj-Napoca, 400124 Cluj-Napoca, Romania
| | - Sorin-Claudiu Man
- Department of Pediatrics, "Iuliu Hațieganu" University of Medicine and Pharmacy Cluj-Napoca, 400124 Cluj-Napoca, Romania
- Clinical Hospital for Pediatric Emergencies, 400124 Cluj-Napoca, Romania
| |
Collapse
|
12
|
Stevenson DK, Marić I, Wong RJ. Breath: The Exhaust of Metabolism. J Pediatr 2023:113386. [PMID: 36925060 DOI: 10.1016/j.jpeds.2023.03.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 03/13/2023] [Indexed: 03/18/2023]
Affiliation(s)
- David K Stevenson
- Department of Pediatrics, Division of Neonatal and Developmental Medicine, Stanford University School of Medicine, Center for Academic Medicine (CAM), 453 Quarry Road, Stanford, CA 94305-5660, USA.
| | - Ivana Marić
- Department of Pediatrics, Division of Neonatal and Developmental Medicine, Stanford University School of Medicine, Center for Academic Medicine (CAM), 453 Quarry Road, Stanford, CA 94305-5660, USA
| | - Ronald J Wong
- Department of Pediatrics, Division of Neonatal and Developmental Medicine, Stanford University School of Medicine, Center for Academic Medicine (CAM), 453 Quarry Road, Stanford, CA 94305-5660, USA
| |
Collapse
|
13
|
Wilson AD, Forse LB. Potential for Early Noninvasive COVID-19 Detection Using Electronic-Nose Technologies and Disease-Specific VOC Metabolic Biomarkers. SENSORS (BASEL, SWITZERLAND) 2023; 23:2887. [PMID: 36991597 PMCID: PMC10054641 DOI: 10.3390/s23062887] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2023] [Revised: 02/19/2023] [Accepted: 03/03/2023] [Indexed: 06/12/2023]
Abstract
The established efficacy of electronic volatile organic compound (VOC) detection technologies as diagnostic tools for noninvasive early detection of COVID-19 and related coronaviruses has been demonstrated from multiple studies using a variety of experimental and commercial electronic devices capable of detecting precise mixtures of VOC emissions in human breath. The activities of numerous global research teams, developing novel electronic-nose (e-nose) devices and diagnostic methods, have generated empirical laboratory and clinical trial test results based on the detection of different types of host VOC-biomarker metabolites from specific chemical classes. COVID-19-specific volatile biomarkers are derived from disease-induced changes in host metabolic pathways by SARS-CoV-2 viral pathogenesis. The unique mechanisms proposed from recent researchers to explain how COVID-19 causes damage to multiple organ systems throughout the body are associated with unique symptom combinations, cytokine storms and physiological cascades that disrupt normal biochemical processes through gene dysregulation to generate disease-specific VOC metabolites targeted for e-nose detection. This paper reviewed recent methods and applications of e-nose and related VOC-detection devices for early, noninvasive diagnosis of SARS-CoV-2 infections. In addition, metabolomic (quantitative) COVID-19 disease-specific chemical biomarkers, consisting of host-derived VOCs identified from exhaled breath of patients, were summarized as possible sources of volatile metabolic biomarkers useful for confirming and supporting e-nose diagnoses.
Collapse
Affiliation(s)
- Alphus Dan Wilson
- Pathology Department, Center for Forest Health & Disturbance, Forest Genetics and Ecosystems Biology, Southern Research Station, USDA Forest Service, Stoneville, MS 38776, USA
| | - Lisa Beth Forse
- Southern Hardwoods Laboratory, Southern Research Station, USDA Forest Service, Stoneville, MS 38776, USA
| |
Collapse
|
14
|
Romijn M, van Kaam AH, Fenn D, Bos LD, van den Akker CHP, Finken MJJ, Rotteveel J, Cerullo J, Brinkman P, Onland W. Exhaled Volatile Organic Compounds for Early Prediction of Bronchopulmonary Dysplasia in Infants Born Preterm. J Pediatr 2023:113368. [PMID: 36868304 DOI: 10.1016/j.jpeds.2023.02.014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 02/10/2023] [Accepted: 02/12/2023] [Indexed: 03/05/2023]
Abstract
OBJECTIVE(S) To investigate the predictive performances of exhaled breath volatile organic compounds (VOCs) for development of bronchopulmonary dysplasia (BPD) in infants born preterm. METHODS Exhaled breath was collected from infants born <30 weeks' gestation at days 3 and 7 of life. Ion-fragments detected by gas-Chromatography-mass-spectrometry analysis were used to derive and internally validate a VOC prediction model for moderate or severe BPD at 36 weeks postmenstrual age. We tested the predictive performance of the National Institute of Child Health and Human Development (NICHD) clinical BPD prediction model with and without VOCs. RESULTS Breath samples were collected from 117 infants (mean gestation 26.8 [±1.5] weeks). Thirty-three percent of the infants developed moderate or severe BPD. The VOC model showed a c-statistic of 0.89 (95% confidence interval [CI] 0.80-0.97) and 0.92 (95% CI 0.84-0.99)) for the prediction of BPD at days 3 and 7, respectively. Adding the VOCs to the clinical prediction model in non-invasive supported infants resulted in significant improvement in discriminative power on both days (day 3: c-statistic 0.83 versus 0.92, p-value 0.04; day 7: c-statistic 0.82 versus 0.94, p-value 0.03). CONCLUSIONS This study showed that VOC profiles in exhaled breath of preterm infants on non-invasive support in the first week of life differ between those developing and not developing BPD. Adding VOCs to a clinical prediction model significantly improved its discriminative performance.
Collapse
Affiliation(s)
- Michelle Romijn
- Amsterdam UMC location University of Amsterdam, Department of Pediatrics-Neonatology, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Reproduction and Development Research Institute, Amsterdam, the Netherlands; Amsterdam UMC location Vrije Universiteit Amsterdam, Department of Pediatric-Endocrinology, Boelelaan 1117, Amsterdam, the Netherlands
| | - Anton H van Kaam
- Amsterdam UMC location University of Amsterdam, Department of Pediatrics-Neonatology, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Reproduction and Development Research Institute, Amsterdam, the Netherlands
| | - Dominic Fenn
- Amsterdam UMC location University of Amsterdam, Department of Respiratory Medicine, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam UMC location University of Amsterdam, Department of laboratory of Experimental Intensive Care and Anaesthesiology, Meibergdreef 9, Amsterdam, the Netherlands
| | - Lieuwe D Bos
- Amsterdam UMC location University of Amsterdam, Department of Respiratory Medicine, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam UMC location University of Amsterdam, Department of laboratory of Experimental Intensive Care and Anaesthesiology, Meibergdreef 9, Amsterdam, the Netherlands
| | - Chris H P van den Akker
- Amsterdam UMC location University of Amsterdam, Department of Pediatrics-Neonatology, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Reproduction and Development Research Institute, Amsterdam, the Netherlands
| | - Martijn J J Finken
- Amsterdam Reproduction and Development Research Institute, Amsterdam, the Netherlands; Amsterdam UMC location Vrije Universiteit Amsterdam, Department of Pediatric-Endocrinology, Boelelaan 1117, Amsterdam, the Netherlands
| | - Joost Rotteveel
- Amsterdam Reproduction and Development Research Institute, Amsterdam, the Netherlands; Amsterdam UMC location Vrije Universiteit Amsterdam, Department of Pediatric-Endocrinology, Boelelaan 1117, Amsterdam, the Netherlands
| | - Julia Cerullo
- Division of Neonatolgy "Villa dei Fiori" Hospital, Acerra, Naples, Italy
| | - Paul Brinkman
- Amsterdam UMC location University of Amsterdam, Department of Respiratory Medicine, Meibergdreef 9, Amsterdam, the Netherlands
| | - Wes Onland
- Amsterdam UMC location University of Amsterdam, Department of Pediatrics-Neonatology, Meibergdreef 9, Amsterdam, the Netherlands; Amsterdam Reproduction and Development Research Institute, Amsterdam, the Netherlands.
| |
Collapse
|
15
|
Kiss H, Örlős Z, Gellért Á, Megyesfalvi Z, Mikáczó A, Sárközi A, Vaskó A, Miklós Z, Horváth I. Exhaled Biomarkers for Point-of-Care Diagnosis: Recent Advances and New Challenges in Breathomics. MICROMACHINES 2023; 14:391. [PMID: 36838091 PMCID: PMC9964519 DOI: 10.3390/mi14020391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Revised: 01/29/2023] [Accepted: 02/02/2023] [Indexed: 06/18/2023]
Abstract
Cancers, chronic diseases and respiratory infections are major causes of mortality and present diagnostic and therapeutic challenges for health care. There is an unmet medical need for non-invasive, easy-to-use biomarkers for the early diagnosis, phenotyping, predicting and monitoring of the therapeutic responses of these disorders. Exhaled breath sampling is an attractive choice that has gained attention in recent years. Exhaled nitric oxide measurement used as a predictive biomarker of the response to anti-eosinophil therapy in severe asthma has paved the way for other exhaled breath biomarkers. Advances in laser and nanosensor technologies and spectrometry together with widespread use of algorithms and artificial intelligence have facilitated research on volatile organic compounds and artificial olfaction systems to develop new exhaled biomarkers. We aim to provide an overview of the recent advances in and challenges of exhaled biomarker measurements with an emphasis on the applicability of their measurement as a non-invasive, point-of-care diagnostic and monitoring tool.
Collapse
Affiliation(s)
- Helga Kiss
- National Koranyi Institute for Pulmonology, Koranyi F Street 1, 1121 Budapest, Hungary
| | - Zoltán Örlős
- National Koranyi Institute for Pulmonology, Koranyi F Street 1, 1121 Budapest, Hungary
| | - Áron Gellért
- National Koranyi Institute for Pulmonology, Koranyi F Street 1, 1121 Budapest, Hungary
| | - Zsolt Megyesfalvi
- National Koranyi Institute for Pulmonology, Koranyi F Street 1, 1121 Budapest, Hungary
| | - Angéla Mikáczó
- Department of Pulmonology, University of Debrecen, Nagyerdei krt 98, 4032 Debrecen, Hungary
| | - Anna Sárközi
- Department of Pulmonology, University of Debrecen, Nagyerdei krt 98, 4032 Debrecen, Hungary
| | - Attila Vaskó
- Department of Pulmonology, University of Debrecen, Nagyerdei krt 98, 4032 Debrecen, Hungary
| | - Zsuzsanna Miklós
- National Koranyi Institute for Pulmonology, Koranyi F Street 1, 1121 Budapest, Hungary
| | - Ildikó Horváth
- National Koranyi Institute for Pulmonology, Koranyi F Street 1, 1121 Budapest, Hungary
- Department of Pulmonology, University of Debrecen, Nagyerdei krt 98, 4032 Debrecen, Hungary
| |
Collapse
|
16
|
Weber R, Kaeslin J, Moeller S, Perkins N, Micic S, Moeller A. Effects of a Volatile Organic Compound Filter on Breath Profiles Measured by Secondary Electrospray High-Resolution Mass Spectrometry. Molecules 2022; 28:molecules28010045. [PMID: 36615240 PMCID: PMC9822030 DOI: 10.3390/molecules28010045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 12/08/2022] [Accepted: 12/08/2022] [Indexed: 12/24/2022] Open
Abstract
Environmental volatile organic compounds (VOCs) from the ambient air potentially influence on-line breath analysis measurements by secondary electrospray ionization high-resolution mass spectrometry (SESI-HRMS). The aim of this study was to investigate how inhaling through a VOC filter affects the detected breath profiles and whether it is feasible to integrate such filters into routine measurements. A total of 24 adult participants performed paired breath analysis measurements with and without the use of an activated carbon filter for inspiration. Concordance correlation coefficients (CCCs) and the Bland−Altman analysis were used to assess the agreement between the two methods. Additionally, the effect on a selection of known metabolites and contaminants was analyzed. Out of all the detected features, 78.3% showed at least a moderate agreement before and after filter usage (CCC > 0.9). The decrease in agreement of the remaining m/z features was mostly associated with reduced signal intensities after filter usage. Although a moderate-to-substantial concordance was found for almost 80% of the m/z features, the filter still had an effect by decreasing signal intensities, not only for contaminants, but also for some of the studied metabolites. Operationally, the use of the filter complicated and slowed down the conductance of measurements, limiting its applicability in clinical studies.
Collapse
Affiliation(s)
- Ronja Weber
- Department of Respiratory Medicine and Childhood Research Center, University Children’s Hospital Zurich, Steinwiesstrasse 75, 8032 Zurich, Switzerland
| | - Jérôme Kaeslin
- Department of Chemistry and Applied Biosciences, Swiss Federal Institute of Technology, Vladimir-Prelog Weg 1-5/10, 8093 Zurich, Switzerland
| | - Sophia Moeller
- Department of Respiratory Medicine and Childhood Research Center, University Children’s Hospital Zurich, Steinwiesstrasse 75, 8032 Zurich, Switzerland
| | - Nathan Perkins
- Division of Clinical Chemistry and Biochemistry, University Children’s Hospital Zurich, Steinwiesstrasse 75, 8032 Zurich, Switzerland
| | - Srdjan Micic
- Department of Respiratory Medicine and Childhood Research Center, University Children’s Hospital Zurich, Steinwiesstrasse 75, 8032 Zurich, Switzerland
- Correspondence: (S.M.); (A.M.)
| | - Alexander Moeller
- Department of Respiratory Medicine and Childhood Research Center, University Children’s Hospital Zurich, Steinwiesstrasse 75, 8032 Zurich, Switzerland
- Faculty of Medicine, University of Zurich, Raemistrasse 71, 8006 Zurich, Switzerland
- Correspondence: (S.M.); (A.M.)
| |
Collapse
|
17
|
Sun P, Shi Y, Shi Y. Bionic sensing system and characterization of exhaled nitric oxide detection based on canine olfaction. PLoS One 2022; 17:e0279003. [PMID: 36534648 PMCID: PMC9762597 DOI: 10.1371/journal.pone.0279003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 11/28/2022] [Indexed: 12/24/2022] Open
Abstract
A quantitative monitoring system for fractional exhaled nitric oxide (FENO) in homes is very important for the control of respiratory diseases such as asthma. To this end, this paper proposes a small bionic sensing system for NO detection in an electronic nose based on analysis of the structure of the canine olfactory system and the airflow pattern in the nasal cavity. The proposed system detected NO at different FENO concentration levels with different bionic sensing systems in the electronic nose, and analyzed the data comparatively. Combined with a backpropagation neural network algorithm, the bionic canine sensing system improved the recognition rate for FENO detection by up to 98.1%. Moreover, electronic noses with a canine bionic sensing system can improve the performance of trace gas detection.
Collapse
Affiliation(s)
- Pengjiao Sun
- The Higher Educational Key Laboratory for Measuring & Control Technology and Instrumentation of Heilongjiang Province, Harbin University of Science and Technology, Harbin, China
- Electronics and Communication Engineering School, Jilin Technology College of Electronic Information, Jilin, China
| | - Yunbo Shi
- The Higher Educational Key Laboratory for Measuring & Control Technology and Instrumentation of Heilongjiang Province, Harbin University of Science and Technology, Harbin, China
- Heilongjiang Province Key Laboratory of Laser Spectroscopy Technology and Application, Harbin University of Science and Technology, Harbin, China
- National Experimental Teaching Demonstration Center for Measurement and Control Technology and Instrumentation, Harbin University of Science and Technology, Harbin, China
- * E-mail:
| | - Yeping Shi
- The Higher Educational Key Laboratory for Measuring & Control Technology and Instrumentation of Heilongjiang Province, Harbin University of Science and Technology, Harbin, China
- Electronics and Communication Engineering School, Jilin Technology College of Electronic Information, Jilin, China
| |
Collapse
|
18
|
Development of an Algorithm for Cervical High-Grade Squamous Intraepithelial Lesion Based on Breath Print Analysis. J Low Genit Tract Dis 2022; 27:7-11. [PMID: 36196881 DOI: 10.1097/lgt.0000000000000707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES This study was designed to develop an algorithm for the diagnosis of cervical high-grade squamous intraepithelial lesions (HSIL), based on patterns of volatile organic compounds, evaluated using an e-nose. METHODS For this pilot study, the study population consisted of a group of 25 patients with histologically confirmed HSIL and a group of 26 controls. Controls consisted of women visiting the outpatient department for gynecological complaints unrelated to cancer. Women had a negative high-risk human papillomavirus and/or normal cytology (negative for intraepithelial lesions of malignancy) of their most recent test performed in the context of participation in routine cervical cancer screening. Breath tests were performed and labeled with the correct diagnosis. Machine-learning techniques were used to develop a model for predicting HSIL. Based on the receiver operating characteristics curve, both sensitivity and specificity were calculated. RESULTS Individual classifications of all patients with HSIL and controls, as calculated by the model, showed a sensitivity of 0.88 (95% CI = 0.68-0.97) and specificity of 0.92 (95% CI = 0.73-0.99). The positive predictive value and the negative predictive value were 0.92 (95% CI = 0.72-0.99) and 0.89 (95% CI = 0.70-0.97), respectively. The Cohen κ coefficient was 0.80. CONCLUSIONS E-nose can detect distinctive patterns of volatile organic compounds between cervical HSIL patients and controls. Validation of the algorithm in further studies is necessary before possible implementation into daily practice.
Collapse
|
19
|
Keogh RJ, Riches JC. The Use of Breath Analysis in the Management of Lung Cancer: Is It Ready for Primetime? Curr Oncol 2022; 29:7355-7378. [PMID: 36290855 PMCID: PMC9600994 DOI: 10.3390/curroncol29100578] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/22/2022] [Accepted: 09/28/2022] [Indexed: 11/07/2022] Open
Abstract
Breath analysis is a promising non-invasive method for the detection and management of lung cancer. Exhaled breath contains a complex mixture of volatile and non-volatile organic compounds that are produced as end-products of metabolism. Several studies have explored the patterns of these compounds and have postulated that a unique breath signature is emitted in the setting of lung cancer. Most studies have evaluated the use of gas chromatography and mass spectrometry to identify these unique breath signatures. With recent advances in the field of analytical chemistry and machine learning gaseous chemical sensing and identification devices have also been created to detect patterns of odorant molecules such as volatile organic compounds. These devices offer hope for a point-of-care test in the future. Several prospective studies have also explored the presence of specific genomic aberrations in the exhaled breath of patients with lung cancer as an alternative method for molecular analysis. Despite its potential, the use of breath analysis has largely been limited to translational research due to methodological issues, the lack of standardization or validation and the paucity of large multi-center studies. It is clear however that it offers a potentially non-invasive alternative to investigations such as tumor biopsy and blood sampling.
Collapse
|
20
|
Anzivino R, Sciancalepore PI, Dragonieri S, Quaranta VN, Petrone P, Petrone D, Quaranta N, Carpagnano GE. The Role of a Polymer-Based E-Nose in the Detection of Head and Neck Cancer from Exhaled Breath. SENSORS (BASEL, SWITZERLAND) 2022; 22:6485. [PMID: 36080944 PMCID: PMC9460264 DOI: 10.3390/s22176485] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 08/21/2022] [Accepted: 08/22/2022] [Indexed: 06/15/2023]
Abstract
The aim of our study was to assess whether a polymer-based e-nose can distinguish head and neck cancer subjects from healthy controls, as well as from patients with allergic rhinitis. A total number of 45 subjects participated in this study. The first group was composed of 15 patients with histology confirmed diagnosis of head and neck cancer. The second group was made up of 15 patients with diagnoses of allergic rhinitis. The control group consisted of 15 subjects with a negative history of upper airways and/or chest symptoms. Exhaled breath was collected from all participants and sampled by a polymer-based e-nose (Cyranose 320, Sensigent, Pasadena, CA, USA). In the Principal Component Analysis plot, patients with head and neck cancer clustered distinctly from the controls as well as from patients with allergic rhinitis. Using canonical discriminant analysis, the three groups were discriminated, with a cross validated accuracy% of 75.1, p < 0.01. The area under the curve of the receiver operating characteristic curve for the discrimination between head and neck cancer patients and the other groups was 0.87. To conclude, e-nose technology has the potential for application in the diagnosis of head and neck cancer, being an easy, quick, non-invasive and cost-effective tool.
Collapse
Affiliation(s)
| | | | - Silvano Dragonieri
- Respiratory Diseases Unit, Department SMBNOS, University of Bari, 70121 Bari, Italy
| | | | | | | | - Nicola Quaranta
- Otolaryngology Unit, Department SMBNOS, University of Bari, 70121 Bari, Italy
| | | |
Collapse
|
21
|
A Gold Nanoparticle-Based Molecular Self-Assembled Colorimetric Chemosensor Array for Monitoring Multiple Organic Oxyanions. Processes (Basel) 2022. [DOI: 10.3390/pr10071251] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
Determination of oxyanions is of paramount importance because of the essential role they play in metabolic processes involved in various aquatic environmental problems. In this investigation, a novel chemical sensor array has been developed by using gold nanoparticles modified with different chain lengths of aminothiols (AET-AuNPs) as sensing elements. The proposed sensor array provides a fingerprint-like response pattern originating from cross-reactive binding events and capable of targeting various anions, including the herbicide glyphosate. In addition, chemometric techniques, linear discrimination analysis (LDA) and the support vector machine (SVM) algorithm were employed for analyte classification and regression/prediction. The obtained sensor array demonstrates a remarkable ability to determine multiple oxyanions in both qualitative and quantitative analysis. The described methodology could be used as a simple, sensitive and fast routine analysis for oxyanions in both laboratory and field settings.
Collapse
|
22
|
Sola-Martínez RA, Sanchez-Solis M, Lozano-Terol G, Gallego-Jara J, García-Marcos L, Cánovas Díaz M, de Diego Puente T. Relationship between lung function and exhaled volatile organic compounds in healthy infants. Pediatr Pulmonol 2022; 57:1282-1292. [PMID: 35092361 PMCID: PMC9304127 DOI: 10.1002/ppul.25849] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 01/21/2022] [Accepted: 01/26/2022] [Indexed: 11/08/2022]
Abstract
OBJECTIVE The aim of this study is to assess, for the first time, the relationship between the volatilome and lung function in healthy infants, which may be of help for the early detection of certain respiratory diseases. Lung function tests are crucial in chronic respiratory diseases diagnosis. Moreover, volatile organic compounds (VOCs) analysis in exhaled breath is a noninvasive technique that enables the monitorization of oxidative stress, typical of some forms of airway inflammation. METHODS Lung function was studied in 50 healthy infants of 3-8 months of age and the following parameters were obtained: forced vital capacity (FVC), forced expiratory volume at 0.5 s (FEV0.5 ), forced expiratory flow at 75% of FVC (FEF75 ), forced expiratory flow at 25%-75% of FVC (FEF25-75 ), and FEV0.5 /FVC. Lung function was measured according to the raised volume rapid thoracoabdominal compression technique. In addition, a targeted analysis of six endogenous VOCs (acetone, isoprene, decane, undecane, tetradecane, and pentadecane) in the exhaled breath of the children was carried out by means of thermal desorption coupled gas chromatography-single quadrupole mass spectrometry system. RESULTS A negatively significant relationship has been observed between levels of acetone, tetradecane, and pentadecane in exhaled breath and several of the lung function parameters. Levels of acetone (feature m/z = 58) were significantly negatively associated with FVC and FVE0.5 , levels of tetradecane (feature m/z = 71) with FEV0.5, and levels of pentadecane (feature m/z = 71) with FEV0.5 and FEF25-75 . CONCLUSION The findings of this study highlight a significant association between VOCs related to oxidative stress and lung function in healthy infants.
Collapse
Affiliation(s)
- Rosa A Sola-Martínez
- Department of Biochemistry and Molecular Biology B and Immunology, University of Murcia, Murcia, Spain.,Group of Molecular Systems Biology, Biomedical Research Institute of Murcia, IMIB-Arrixaca, Murcia, Spain
| | - Manuel Sanchez-Solis
- Group of Pediatric Research, Biomedical Research Institute of Murcia, IMIB-Arrixaca, Murcia, Spain.,Respiratory and Allergy Units, Arrixaca Children's University Hospital, University of Murcia, Murcia, Spain.,Network of Asthma and Adverse and Allergy Reactions (ARADyAL), Health Institute Carlos III, Madrid, Spain
| | - Gema Lozano-Terol
- Department of Biochemistry and Molecular Biology B and Immunology, University of Murcia, Murcia, Spain.,Group of Molecular Systems Biology, Biomedical Research Institute of Murcia, IMIB-Arrixaca, Murcia, Spain
| | - Julia Gallego-Jara
- Department of Biochemistry and Molecular Biology B and Immunology, University of Murcia, Murcia, Spain.,Group of Molecular Systems Biology, Biomedical Research Institute of Murcia, IMIB-Arrixaca, Murcia, Spain
| | - Luis García-Marcos
- Group of Pediatric Research, Biomedical Research Institute of Murcia, IMIB-Arrixaca, Murcia, Spain.,Respiratory and Allergy Units, Arrixaca Children's University Hospital, University of Murcia, Murcia, Spain.,Network of Asthma and Adverse and Allergy Reactions (ARADyAL), Health Institute Carlos III, Madrid, Spain
| | - Manuel Cánovas Díaz
- Department of Biochemistry and Molecular Biology B and Immunology, University of Murcia, Murcia, Spain.,Group of Molecular Systems Biology, Biomedical Research Institute of Murcia, IMIB-Arrixaca, Murcia, Spain
| | - Teresa de Diego Puente
- Department of Biochemistry and Molecular Biology B and Immunology, University of Murcia, Murcia, Spain.,Group of Molecular Systems Biology, Biomedical Research Institute of Murcia, IMIB-Arrixaca, Murcia, Spain
| | | |
Collapse
|
23
|
V R N, Mohapatra AK, V K U, Lukose J, Kartha VB, Chidangil S. Post-COVID syndrome screening through breath analysis using electronic nose technology. Anal Bioanal Chem 2022; 414:3617-3624. [PMID: 35303135 PMCID: PMC8930465 DOI: 10.1007/s00216-022-03990-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 02/15/2022] [Accepted: 02/25/2022] [Indexed: 11/26/2022]
Abstract
There is an urgent need to have reliable technologies to diagnose post-coronavirus disease syndrome (PCS), as the number of people affected by COVID-19 and related complications is increasing worldwide. Considering the amount of risks associated with the two chronic lung diseases, asthma and chronic obstructive pulmonary disease (COPD), there is an immediate requirement for a screening method for PCS, which also produce symptoms similar to these conditions, especially since very often, many COVID-19 cases remain undetected because a good share of such patients is asymptomatic. Breath analysis techniques are getting attention since they are highly non-invasive methods for disease diagnosis, can be implemented easily for point-of-care applications even in primary health care centres. Electronic (E-) nose technology is coming up with better reliability, ease of operation, and affordability to all, and it can generate signatures of volatile organic compounds (VOCs) in exhaled breath as markers of diseases. The present report is an outcome of a pilot study using an E-nose device on breath samples of cohorts of PCS, asthma, and normal (control) subjects. Match/no-match and k-NN analysis tests have been carried out to confirm the diagnosis of PCS. The prediction model has given 100% sensitivity and specificity. Receiver operating characteristics (ROC) has been plotted for the prediction model, and the area under the curve (AUC) is obtained as 1. The E-nose technique is found to be working well for PCS diagnosis. Our study suggests that the breath analysis using E-nose can be used as a point-of-care diagnosis of PCS. Trial registration Breath samples were collected from the Kasturba Hospital, Manipal. Ethical clearance was obtained from the Institutional Ethics Committee, Kasturba Medical College, Manipal (IEC 60/2021, 13/01/2021) and Indian Council of Medical Research (ICMR) (CTRI/2021/02/031357, 06/02/2021) Government of India; trials were prospectively registered.
Collapse
Affiliation(s)
- Nidheesh V R
- Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India, 576104
| | - Aswini Kumar Mohapatra
- Department of Respiratory Medicine, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India, 576104
| | - Unnikrishnan V K
- Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India, 576104
| | - Jijo Lukose
- Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India, 576104
| | - Vasudevan Baskaran Kartha
- Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India, 576104
| | - Santhosh Chidangil
- Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India, 576104.
| |
Collapse
|
24
|
Predicting Early Hospital Readmissions in COPD Patients Using an Electronic Nose. ARCHIVOS DE BRONCONEUMOLOGÍA 2022; 58:663-665. [DOI: 10.1016/j.arbres.2022.01.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 01/11/2022] [Accepted: 01/17/2022] [Indexed: 11/23/2022]
|
25
|
[Translated article] Study of diffuse interstitial lung disease with the analysis of volatile particles in exhaled air. Arch Bronconeumol 2022. [DOI: 10.1016/j.arbres.2021.03.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
26
|
Assessing Gut Microbiota in an Infant with Congenital Propionic Acidemia before and after Probiotic Supplementation. Microorganisms 2021; 9:microorganisms9122599. [PMID: 34946200 PMCID: PMC8703847 DOI: 10.3390/microorganisms9122599] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 11/25/2021] [Accepted: 12/13/2021] [Indexed: 12/12/2022] Open
Abstract
Propionic Acidemia (PA) is a rare inherited metabolic disorder caused by the enzymatic block of propionyl-CoA carboxylase with the consequent accumulation of propionic acid, which is toxic for the brain and cardiac cells. Since a considerable amount of propionate is produced by intestinal bacteria, interest arose in the attempt to reduce propionate-producing bacteria through a monthly antibiotic treatment of metronidazole. In the present study, we investigated the gut microbiota structure of an infant diagnosed at 4 days of life through Expanded Newborn Screening (NBS) and treated the child following international guidelines with a special low-protein diet, specific medications and strict biochemical monitoring. Microbiota composition was assessed during the first month of life, and the presence of Bacteroides fragilis, known to be associated with propionate production, was effectively decreased by metronidazole treatment. After five antibiotic therapy cycles, at 4 months of age, the infant was supplemented with a daily mixture of three bifidobacterial strains, known not to be propionate producers. The supplementation increased the population of bifidobacteria, with Bifidobacterium breve as the dominating species; Ruminococcus gnavus, an acetate and formate producer, was also identified. Metabarcoding analysis, compared with low coverage whole metagenome sequencing, proved to capture all the microbial biodiversity and could be the elected tool for fast and cost-effective monitoring protocols to be implemented in the follow up of rare metabolic disorders such as PA. Data obtained could be a possible starting point to set up tailored microbiota modification treatment studies in the attempt to improve the quality of life of people affected by propionic acidemia.
Collapse
|
27
|
Virtanen J, Anttalainen A, Ormiskangas J, Karjalainen M, Kontunen A, Rautiainen M, Oksala N, Kivekäs I, Roine A. Differentiation of aspirated nasal air from room air using analysis with a differential mobility spectrometry-based electronic nose: a proof-of-concept study. J Breath Res 2021; 16. [PMID: 34794137 DOI: 10.1088/1752-7163/ac3b39] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2021] [Accepted: 11/18/2021] [Indexed: 12/17/2022]
Abstract
Over the last few decades, breath analysis using electronic nose (eNose) technology has become a topic of intense research, as it is both non-invasive and painless, and is suitable for point-of-care use. To date, however, only a few studies have examined nasal air. As the air in the oral cavity and the lungs differs from the air in the nasal cavity, it is unknown whether aspirated nasal air could be exploited with eNose technology. Compared to traditional eNoses, differential mobility spectrometry uses an alternating electrical field to discriminate the different molecules of gas mixtures, providing analogous information. This study reports the collection of nasal air by aspiration and the subsequent analysis of the collected air using a differential mobility spectrometer. We collected nasal air from ten volunteers into breath collecting bags and compared them to bags of room air and the air aspirated through the device. Distance and dissimilarity metrics between the sample types were calculated and statistical significance evaluated with Kolmogorov-Smirnov test. After leave-one-day-out cross-validation, a shrinkage linear discriminant classifier was able to correctly classify 100% of the samples. The nasal air differed (p< 0.05) from the other sample types. The results show the feasibility of collecting nasal air by aspiration and subsequent analysis using differential mobility spectrometry, and thus increases the potential of the method to be used in disease detection studies.
Collapse
Affiliation(s)
- Jussi Virtanen
- Department of Otorhinolaryngology, Head and Neck Surgery, Tampere University Hospital, Tampere, Finland.,Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | | | - Jaakko Ormiskangas
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.,Faculty of Engineering and Natural Sciences, Automation Technology and Mechanical Engineering Unit, Tampere University, Tampere, Finland
| | - Markus Karjalainen
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.,Olfactomics Ltd, Tampere, Finland
| | - Anton Kontunen
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.,Olfactomics Ltd, Tampere, Finland
| | - Markus Rautiainen
- Department of Otorhinolaryngology, Head and Neck Surgery, Tampere University Hospital, Tampere, Finland.,Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Niku Oksala
- Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.,Olfactomics Ltd, Tampere, Finland.,Vascular Centre, Tampere University Hospital, Tampere, Finland
| | - Ilkka Kivekäs
- Department of Otorhinolaryngology, Head and Neck Surgery, Tampere University Hospital, Tampere, Finland.,Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Antti Roine
- Olfactomics Ltd, Tampere, Finland.,Department of Surgery, Tampere University Hospital, Hatanpää Hospital, Tampere, Finland
| |
Collapse
|
28
|
van der Sar IG, Wijbenga N, Nakshbandi G, Aerts JGJV, Manintveld OC, Wijsenbeek MS, Hellemons ME, Moor CC. The smell of lung disease: a review of the current status of electronic nose technology. Respir Res 2021; 22:246. [PMID: 34535144 PMCID: PMC8448171 DOI: 10.1186/s12931-021-01835-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Accepted: 08/26/2021] [Indexed: 02/08/2023] Open
Abstract
There is a need for timely, accurate diagnosis, and personalised management in lung diseases. Exhaled breath reflects inflammatory and metabolic processes in the human body, especially in the lungs. The analysis of exhaled breath using electronic nose (eNose) technology has gained increasing attention in the past years. This technique has great potential to be used in clinical practice as a real-time non-invasive diagnostic tool, and for monitoring disease course and therapeutic effects. To date, multiple eNoses have been developed and evaluated in clinical studies across a wide spectrum of lung diseases, mainly for diagnostic purposes. Heterogeneity in study design, analysis techniques, and differences between eNose devices currently hamper generalization and comparison of study results. Moreover, many pilot studies have been performed, while validation and implementation studies are scarce. These studies are needed before implementation in clinical practice can be realised. This review summarises the technical aspects of available eNose devices and the available evidence for clinical application of eNose technology in different lung diseases. Furthermore, recommendations for future research to pave the way for clinical implementation of eNose technology are provided.
Collapse
Affiliation(s)
- I G van der Sar
- Department of Respiratory Medicine, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - N Wijbenga
- Department of Respiratory Medicine, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - G Nakshbandi
- Department of Respiratory Medicine, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - J G J V Aerts
- Department of Respiratory Medicine, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - O C Manintveld
- Department of Cardiology, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - M S Wijsenbeek
- Department of Respiratory Medicine, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - M E Hellemons
- Department of Respiratory Medicine, Erasmus MC, University Medical Center, Rotterdam, The Netherlands
| | - C C Moor
- Department of Respiratory Medicine, Erasmus MC, University Medical Center, Rotterdam, The Netherlands.
| |
Collapse
|
29
|
Bae G, Kim M, Song W, Myung S, Lee SS, An KS. Impact of a Diverse Combination of Metal Oxide Gas Sensors on Machine Learning-Based Gas Recognition in Mixed Gases. ACS OMEGA 2021; 6:23155-23162. [PMID: 34549116 PMCID: PMC8444204 DOI: 10.1021/acsomega.1c02721] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 08/16/2021] [Indexed: 06/13/2023]
Abstract
A challenge for chemiresistive-type gas sensors distinguishing mixture gases is that for highly accurate recognition, massive data processing acquired from various types of sensor configurations must be considered. The impact of data processing is indeed ineffective and time-consuming. Herein, we systemically investigate the effect of the selectivity for a target gas on the prediction accuracy of gas concentration via machine learning based on a support vector machine model. The selectivity factor S(X) of a gas sensor for a target gas "X" is introduced to reveal the correlation between the prediction accuracy and selectivity of gas sensors. The presented work suggests that (i) the strong correlation between the selectivity factor and prediction accuracy has a proportional relationship, (ii) the enhancement of the prediction accuracy of an elemental sensor with a low sensitivity factor can be attained by a complementary combination of the other sensor with a high selectivity factor, and (iii) it can also be boosted by combining the sensor having even a low selectivity factor.
Collapse
|
30
|
Exhaled volatilome analysis as a useful tool to discriminate asthma with other coexisting atopic diseases in women of childbearing age. Sci Rep 2021; 11:13823. [PMID: 34226570 PMCID: PMC8257728 DOI: 10.1038/s41598-021-92933-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2021] [Accepted: 06/14/2021] [Indexed: 02/06/2023] Open
Abstract
The prevalence of asthma is considerably high among women of childbearing age. Most asthmatic women also often have other atopic disorders. Therefore, the differentiation between patients with atopic diseases without asthma and asthmatics with coexisting diseases is essential to avoid underdiagnosis of asthma and to design strategies to reduce symptom severity and improve quality of life of patients. Hence, we aimed for the first time to conduct an analysis of volatile organic compounds in exhaled breath of women of childbearing age as a new approach to discriminate between asthmatics with other coexisting atopic diseases and non-asthmatics (with or without atopic diseases), which could be a helpful tool for more accurate asthma detection and monitoring using a noninvasive technique in the near future. In this study, exhaled air samples of 336 women (training set (n = 211) and validation set (n = 125)) were collected and analyzed by thermal desorption coupled with gas chromatography-mass spectrometry. ASCA (ANOVA (analysis of variance) simultaneous component analysis) and LASSO + LS (least absolute shrinkage and selection operator + logistic regression) were employed for data analysis. Fifteen statistically significant models (p-value < 0.05 in permutation tests) that discriminated asthma with other coexisting atopic diseases in women of childbearing age were generated. Acetone, 2-ethyl-1-hexanol and a tetrahydroisoquinoline derivative were selected as discriminants of asthma with other coexisting atopic diseases. In addition, carbon disulfide, a tetrahydroisoquinoline derivative, 2-ethyl-1-hexanol and decane discriminated asthma disease among patients with other atopic disorders. Results of this study indicate that refined metabolomic analysis of exhaled breath allows asthma with other coexisting atopic diseases discrimination in women of reproductive age.
Collapse
|
31
|
Ibrahim W, Natarajan S, Wilde M, Cordell R, Monks PS, Greening N, Brightling CE, Evans R, Siddiqui S. A systematic review of the diagnostic accuracy of volatile organic compounds in airway diseases and their relation to markers of type-2 inflammation. ERJ Open Res 2021; 7:00030-2021. [PMID: 34476250 PMCID: PMC8405872 DOI: 10.1183/23120541.00030-2021] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 03/27/2021] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND Asthma and COPD continue to cause considerable diagnostic and treatment stratification challenges. Volatile organic compounds (VOCs) have been proposed as feasible diagnostic and monitoring biomarkers in airway diseases. AIMS To 1) conduct a systematic review evaluating the diagnostic accuracy of VOCs in diagnosing airway diseases; 2) understand the relationship between reported VOCs and biomarkers of type-2 inflammation; 3) assess the standardisation of reporting according to STARD and TRIPOD criteria; 4) review current methods of breath sampling and analysis. METHODS A PRISMA-oriented systematic search was conducted (January 1997 to December 2020). Search terms included: "asthma", "volatile organic compound(s)", "VOC" and "COPD". Two independent reviewers examined the extracted titles against review objectives. RESULTS 44 full-text papers were included; 40/44 studies were cross-sectional and four studies were interventional in design; 17/44 studies used sensor-array technologies (e.g. eNose). Cross-study comparison was not possible across identified studies due to the heterogeneity in design. The commonest airway diseases differentiating VOCs belonged to carbonyl-containing classes (i.e. aldehydes, esters and ketones) and hydrocarbons (i.e. alkanes and alkenes). Although individual markers that are associated with clinical biomarkers of type-2 inflammation were recognised (i.e. ethane and 3,7-dimethylnonane for asthma and α-methylstyrene and decane for COPD), these were not consistently identified across studies. Only 3/44 reported following STARD or TRIPOD criteria for diagnostic accuracy and multivariate reporting, respectively. CONCLUSIONS Breath VOCs show promise as diagnostic biomarkers of airway diseases and for type-2 inflammation profiling. However, future studies should focus on transparent reporting of diagnostic accuracy and multivariate models and continue to focus on chemical identification of volatile metabolites.
Collapse
Affiliation(s)
- Wadah Ibrahim
- Leicester NIHR Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK
- Dept of Respiratory Sciences, College of Life Sciences, University of Leicester, Leicester, UK
- These authors contributed equally
| | - Sushiladevi Natarajan
- Leicester NIHR Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK
- Dept of Respiratory Sciences, College of Life Sciences, University of Leicester, Leicester, UK
- These authors contributed equally
| | - Michael Wilde
- Dept of Chemistry, University of Leicester, Leicester, UK
| | | | - Paul S. Monks
- Dept of Chemistry, University of Leicester, Leicester, UK
| | - Neil Greening
- Leicester NIHR Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK
- Dept of Respiratory Sciences, College of Life Sciences, University of Leicester, Leicester, UK
| | - Christopher E. Brightling
- Leicester NIHR Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK
- Dept of Respiratory Sciences, College of Life Sciences, University of Leicester, Leicester, UK
| | - Rachael Evans
- Leicester NIHR Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK
- Dept of Respiratory Sciences, College of Life Sciences, University of Leicester, Leicester, UK
| | - Salman Siddiqui
- Leicester NIHR Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK
- Dept of Respiratory Sciences, College of Life Sciences, University of Leicester, Leicester, UK
- See Acknowledgements for contributors
| |
Collapse
|
32
|
Dragonieri S, Quaranta VN, Carratù P, Ranieri T, Buonamico E, Carpagnano GE. Breathing Rhythm Variations during Wash-In Do Not Influence Exhaled Volatile Organic Compound Profile Analyzed by an Electronic Nose. Molecules 2021; 26:molecules26092695. [PMID: 34064506 PMCID: PMC8124182 DOI: 10.3390/molecules26092695] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 04/21/2021] [Accepted: 05/03/2021] [Indexed: 11/24/2022] Open
Abstract
E-noses are innovative tools used for exhaled volatile organic compound (VOC) analysis, which have shown their potential in several diseases. Before obtaining a full validation of these instruments in clinical settings, a number of methodological issues still have to be established. We aimed to assess whether variations in breathing rhythm during wash-in with VOC-filtered air before exhaled air collection reflect changes in the exhaled VOC profile when analyzed by an e-nose (Cyranose 320). We enrolled 20 normal subjects and randomly collected their exhaled breath at three different breathing rhythms during wash-in: (a) normal rhythm (respiratory rate (RR) between 12 and 18/min), (b) fast rhythm (RR > 25/min) and (c) slow rhythm (RR < 10/min). Exhaled breath was collected by a previously validated method (Dragonieri et al., J. Bras. Pneumol. 2016) and analyzed by the e-nose. Using principal component analysis (PCA), no significant variations in the exhaled VOC profile were shown among the three breathing rhythms. Subsequent linear discriminant analysis (LDA) confirmed the above findings, with a cross-validated accuracy of 45% (p = ns). We concluded that the exhaled VOC profile, analyzed by an e-nose, is not influenced by variations in breathing rhythm during wash-in.
Collapse
Affiliation(s)
- Silvano Dragonieri
- Respiratory Diseases, University of Bari, 70121 Bari, Italy; (T.R.); (E.B.); (G.E.C.)
- Correspondence:
| | | | - Pierluigi Carratù
- Internal Medicine “A. Murri”, University of Bari, 70121 Bari, Italy;
| | - Teresa Ranieri
- Respiratory Diseases, University of Bari, 70121 Bari, Italy; (T.R.); (E.B.); (G.E.C.)
| | - Enrico Buonamico
- Respiratory Diseases, University of Bari, 70121 Bari, Italy; (T.R.); (E.B.); (G.E.C.)
| | | |
Collapse
|
33
|
Ibrahim W, Carr L, Cordell R, Wilde MJ, Salman D, Monks PS, Thomas P, Brightling CE, Siddiqui S, Greening NJ. Breathomics for the clinician: the use of volatile organic compounds in respiratory diseases. Thorax 2021; 76:514-521. [PMID: 33414240 PMCID: PMC7611078 DOI: 10.1136/thoraxjnl-2020-215667] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2020] [Revised: 10/28/2020] [Accepted: 12/03/2020] [Indexed: 01/17/2023]
Abstract
Exhaled breath analysis has the potential to provide valuable insight on the status of various metabolic pathways taking place in the lungs locally and other vital organs, via systemic circulation. For years, volatile organic compounds (VOCs) have been proposed as feasible alternative diagnostic and prognostic biomarkers for different respiratory pathologies.We reviewed the currently published literature on the discovery of exhaled breath VOCs and their utilisation in various respiratory diseasesKey barriers in the development of clinical breath tests include the lack of unified consensus for breath collection and analysis and the complexity of understanding the relationship between the exhaled VOCs and the underlying metabolic pathways. We present a comprehensive overview, in light of published literature and our experience from coordinating a national breathomics centre, of the progress made to date and some of the key challenges in the field and ways to overcome them. We particularly focus on the relevance of breathomics to clinicians and the valuable insights it adds to diagnostics and disease monitoring.Breathomics holds great promise and our findings merit further large-scale multicentre diagnostic studies using standardised protocols to help position this novel technology at the centre of respiratory disease diagnostics.
Collapse
Affiliation(s)
- Wadah Ibrahim
- Department of Respiratory Sciences, University of Leicester, Leicester, UK
- Institute for Lung Health, Leicester NIHR Biomedical Research Centre, Leicester, UK
| | - Liesl Carr
- Institute for Lung Health, Leicester NIHR Biomedical Research Centre, Leicester, UK
| | | | | | - Dahlia Salman
- Department of Chemistry, Loughborough University, Loughborough, UK
| | - Paul S Monks
- School of Chemistry, University of Leicester, Leicester, UK
| | - Paul Thomas
- Department of Chemistry, Loughborough University, Loughborough, UK
| | - Chris E Brightling
- Department of Respiratory Sciences, University of Leicester, Leicester, UK
- Institute for Lung Health, Leicester NIHR Biomedical Research Centre, Leicester, UK
| | - Salman Siddiqui
- Department of Respiratory Sciences, University of Leicester, Leicester, UK
- Institute for Lung Health, Leicester NIHR Biomedical Research Centre, Leicester, UK
| | - Neil J Greening
- Department of Respiratory Sciences, University of Leicester, Leicester, UK
- Institute for Lung Health, Leicester NIHR Biomedical Research Centre, Leicester, UK
| |
Collapse
|
34
|
Sola Martínez RA, Pastor Hernández JM, Yanes Torrado Ó, Cánovas Díaz M, de Diego Puente T, Vinaixa Crevillent M. Exhaled volatile organic compounds analysis in clinical pediatrics: a systematic review. Pediatr Res 2021; 89:1352-1363. [PMID: 32919397 DOI: 10.1038/s41390-020-01116-8] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 07/09/2020] [Accepted: 08/04/2020] [Indexed: 02/08/2023]
Abstract
BACKGROUND Measured exhaled volatile organic compounds (VOCs) in breath also referred to as exhaled volatilome have been long claimed as a potential source of non-invasive and clinically applicable biomarkers. However, the feasibility of using exhaled volatilome in clinical practice remains to be demonstrated, particularly in pediatrics where the need for improved non-invasive diagnostic and monitoring methods is most urgent. This work presents the first formal evidence-based judgment of the clinical potential of breath volatilome in the pediatric population. METHODS A rigorous systematic review across Web of Science, SCOPUS, and PubMed databases following the PRISMA statement guidelines. A narrative synthesis of the evidence was conducted and QUADAS-2 was used to assess the quality of selected studies. RESULTS Two independent reviewers deemed 22 out of the 229 records initially found to satisfy inclusion criteria. A summary of breath VOCs found to be relevant for several respiratory, infectious, and metabolic pathologies was conducted. In addition, we assessed their associated metabolism coverage through a functional characterization analysis. CONCLUSION Our results indicate that current research remains stagnant in a preclinical exploratory setting. Designing exploratory experiments in compliance with metabolomics practice should drive forward the clinical translation of VOCs breath analysis. IMPACT What is the key message of your article? Metabolomics practice could help to achieve the clinical utility of exhaled volatilome analysis. What does it add to the existing literature? This work is the first systematic review focused on disease status discrimination using analysis of exhaled breath in the pediatric population. A summary of the reported exhaled volatile organic compounds is conducted together with a functional characterization analysis. What is the impact? Having noted challenges preventing the clinical translation, we summary metabolomics practices and the experimental designs that are closer to clinical practice to create a framework to guide future trials.
Collapse
Affiliation(s)
- Rosa A Sola Martínez
- Department of Biochemistry and Molecular Biology (B) and Immunology, University of Murcia and Murcian Institute of Biosanitary Research Virgen de la Arrixaca (IMIB), Murcia, Spain
| | - José M Pastor Hernández
- Department of Biochemistry and Molecular Biology (B) and Immunology, University of Murcia and Murcian Institute of Biosanitary Research Virgen de la Arrixaca (IMIB), Murcia, Spain
| | - Óscar Yanes Torrado
- Department of Electronic Engineering, Universitat Rovira i Virgili, Tarragona, Spain.,Institut d'Investigació Sanitària Pere Virgili (IISPV), Metabolomics Platform, Reus, Spain.,CIBER de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Instituto de Salud Carlos III, Madrid, Spain
| | - Manuel Cánovas Díaz
- Department of Biochemistry and Molecular Biology (B) and Immunology, University of Murcia and Murcian Institute of Biosanitary Research Virgen de la Arrixaca (IMIB), Murcia, Spain
| | - Teresa de Diego Puente
- Department of Biochemistry and Molecular Biology (B) and Immunology, University of Murcia and Murcian Institute of Biosanitary Research Virgen de la Arrixaca (IMIB), Murcia, Spain.
| | - María Vinaixa Crevillent
- Department of Electronic Engineering, Universitat Rovira i Virgili, Tarragona, Spain.,Institut d'Investigació Sanitària Pere Virgili (IISPV), Metabolomics Platform, Reus, Spain.,CIBER de Diabetes y Enfermedades Metabólicas Asociadas (CIBERDEM), Instituto de Salud Carlos III, Madrid, Spain
| |
Collapse
|
35
|
Zanella D, Guiot J, Stefanuto PH, Giltay L, Henket M, Guissard F, André B, Malaise M, Potjewijd J, Schleich F, Louis R, Focant JF. Breathomics to diagnose systemic sclerosis using thermal desorption and comprehensive two-dimensional gas chromatography high-resolution time-of-flight mass spectrometry. Anal Bioanal Chem 2021; 413:3813-3822. [PMID: 33903944 DOI: 10.1007/s00216-021-03333-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 03/11/2021] [Accepted: 04/08/2021] [Indexed: 11/29/2022]
Abstract
Systemic sclerosis is a rare autoimmune disease associated with rapidly evolving interstitial lung disease, responsible for the disease severity and mortality. Specific biomarkers enabling the early diagnosis and prognosis associated with the disease progression are highly needed. Volatile organic compounds in exhaled breath are widely available and non-invasive and have the potential to reflect metabolic processes occurring within the body. Comprehensive two-dimensional gas chromatography coupled to high-resolution mass spectrometry was used to investigate the potential of exhaled breath to diagnose systemic sclerosis. The exhaled breath of 32 patients and 30 healthy subjects was analyzed. The high resolving power of this approach enabled the detection of 356 compounds in the breath of systemic sclerosis patients, which was characterized by an increase of mainly terpenoids and hydrocarbons. In addition, the use of 4 complementary statistical approaches (two-tailed equal variance t-test, fold change, partial least squares discriminant analysis, and random forest) resulted in the identification of 16 compounds that can be used to discriminate systemic sclerosis patients from healthy subjects. Receiver operating curves were generated that provided an accuracy of 90%, a sensitivity of 92%, and a specificity of 89%. The chemical identification of eight compounds predictive of systemic sclerosis was validated using commercially available standards. The analytical variations together with the volatile composition of room air were carefully monitored during the timeframe of the study to ensure the robustness of the technique. This study represents the first reported evaluation of exhaled breath analysis for systemic sclerosis diagnosis and provides surrogate markers for such disease.
Collapse
Affiliation(s)
- Delphine Zanella
- Molecular System, Organic & Biological Analytical Chemistry Group, University of Liege, 11 Allee du Six Aout, 4000, Liege, Belgium.
| | - Julien Guiot
- Respiratory Medicine, GIGA I3, CHU Liege, 4000, Liege, Belgium
| | - Pierre-Hugues Stefanuto
- Molecular System, Organic & Biological Analytical Chemistry Group, University of Liege, 11 Allee du Six Aout, 4000, Liege, Belgium
| | - Laurie Giltay
- Respiratory Medicine, GIGA I3, CHU Liege, 4000, Liege, Belgium
| | - Monique Henket
- Respiratory Medicine, GIGA I3, CHU Liege, 4000, Liege, Belgium
| | | | - Béatrice André
- Rheumatology Department, CHU Liege, 4000, Liege, Belgium
| | - Michel Malaise
- Rheumatology Department, CHU Liege, 4000, Liege, Belgium
| | - Judith Potjewijd
- Department of Internal Medicine, Division of Clinical and Experimental Immunology, Maastricht University Medical Center, 6229 HX, Maastricht, The Netherlands
| | | | - Renaud Louis
- Respiratory Medicine, GIGA I3, CHU Liege, 4000, Liege, Belgium
| | - Jean-François Focant
- Molecular System, Organic & Biological Analytical Chemistry Group, University of Liege, 11 Allee du Six Aout, 4000, Liege, Belgium
| |
Collapse
|
36
|
Sharma R, Zang W, Zhou M, Schafer N, Begley LA, Huang YJ, Fan X. Real Time Breath Analysis Using Portable Gas Chromatography for Adult Asthma Phenotypes. Metabolites 2021; 11:265. [PMID: 33922762 PMCID: PMC8145057 DOI: 10.3390/metabo11050265] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2021] [Revised: 04/21/2021] [Accepted: 04/22/2021] [Indexed: 11/24/2022] Open
Abstract
Asthma is heterogeneous but accessible biomarkers to distinguish relevant phenotypes remain lacking, particularly in non-Type 2 (T2)-high asthma. Moreover, common clinical characteristics in both T2-high and T2-low asthma (e.g., atopy, obesity, inhaled steroid use) may confound interpretation of putative biomarkers and of underlying biology. This study aimed to identify volatile organic compounds (VOCs) in exhaled breath that distinguish not only asthmatic and non-asthmatic subjects, but also atopic non-asthmatic controls and also by variables that reflect clinical differences among asthmatic adults. A total of 73 participants (30 asthma, eight atopic non-asthma, and 35 non-asthma/non-atopic subjects) were recruited for this pilot study. A total of 79 breath samples were analyzed in real-time using an automated portable gas chromatography (GC) device developed in-house. GC-mass spectrometry was also used to identify the VOCs in breath. Machine learning, linear discriminant analysis, and principal component analysis were used to identify the biomarkers. Our results show that the portable GC was able to complete breath analysis in 30 min. A set of nine biomarkers distinguished asthma and non-asthma/non-atopic subjects, while sets of two and of four biomarkers, respectively, further distinguished asthmatic from atopic controls, and between atopic and non-atopic controls. Additional unique biomarkers were identified that discriminate subjects by blood eosinophil levels, obese status, inhaled corticosteroid treatment, and also acute upper respiratory illnesses within asthmatic groups. Our work demonstrates that breath VOC profiling can be a clinically accessible tool for asthma diagnosis and phenotyping. A portable GC system is a viable option for rapid assessment in asthma.
Collapse
Affiliation(s)
- Ruchi Sharma
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA; (R.S.); (W.Z.); (M.Z.)
| | - Wenzhe Zang
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA; (R.S.); (W.Z.); (M.Z.)
| | - Menglian Zhou
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA; (R.S.); (W.Z.); (M.Z.)
| | - Nicole Schafer
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, MI 48109, USA; (N.S.); (L.A.B.)
| | - Lesa A. Begley
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, MI 48109, USA; (N.S.); (L.A.B.)
| | - Yvonne J. Huang
- Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, University of Michigan, Ann Arbor, MI 48109, USA; (N.S.); (L.A.B.)
| | - Xudong Fan
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA; (R.S.); (W.Z.); (M.Z.)
| |
Collapse
|
37
|
Castillo Villegas D, Barril S, Giner J, Millan-Billi P, Rodrigo-Troyano A, Merino JL, Sibila O. Study of Diffuse Interstitial Lung Disease With the Analysis of Volatile Particles in Exhaled Air. Arch Bronconeumol 2021; 58:99-101. [PMID: 33867204 DOI: 10.1016/j.arbres.2021.03.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2021] [Accepted: 03/02/2021] [Indexed: 12/01/2022]
Affiliation(s)
- Diego Castillo Villegas
- Servicio de Neumología, Hospital de la Santa Creu i Sant Pau, IIB-Sant Pau, Barcelona, España.
| | - Silvia Barril
- Servicio de Neumología, Hospital de la Santa Creu i Sant Pau, IIB-Sant Pau, Barcelona, España; Servicio de Neumología, Hospital Arnau de Vilanova, Lleida, España
| | - Jordi Giner
- Servicio de Neumología, Hospital de la Santa Creu i Sant Pau, IIB-Sant Pau, Barcelona, España
| | - Paloma Millan-Billi
- Servicio de Neumología, Hospital de la Santa Creu i Sant Pau, IIB-Sant Pau, Barcelona, España; Servicio de Neumología, Hospital Arnau de Vilanova, Lleida, España; Servicio de Neumologia, Hospital Germans Trias i Pujol, Badalona, España
| | - Ana Rodrigo-Troyano
- Servicio de Neumología, Hospital de la Santa Creu i Sant Pau, IIB-Sant Pau, Barcelona, España; Servicio de Neumología, Hospital Arnau de Vilanova, Lleida, España; Servicio de Neumologia, Hospital Germans Trias i Pujol, Badalona, España; Servicio de Neumología, Hospital Son Espases, Palma de Mallorca, España
| | - Jose Luis Merino
- Electronic Systems Group, Universitat de les Illes Balears, Palma de Mallorca, España
| | - Oriol Sibila
- Servicio de Neumología, Hospital de la Santa Creu i Sant Pau, IIB-Sant Pau, Barcelona, España; Instituto del Tórax, Servicio de Neumología, Hospital Clínic, Universitat de Barcelona, IDIBAPS, CIBERES, Barcelona, España
| |
Collapse
|
38
|
Monedeiro F, Monedeiro-Milanowski M, Ratiu IA, Brożek B, Ligor T, Buszewski B. Needle Trap Device-GC-MS for Characterization of Lung Diseases Based on Breath VOC Profiles. Molecules 2021; 26:molecules26061789. [PMID: 33810121 PMCID: PMC8004837 DOI: 10.3390/molecules26061789] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 03/16/2021] [Accepted: 03/19/2021] [Indexed: 01/08/2023] Open
Abstract
Volatile organic compounds (VOCs) have been assessed in breath samples as possible indicators of diseases. The present study aimed to quantify 29 VOCs (previously reported as potential biomarkers of lung diseases) in breath samples collected from controls and individuals with lung cancer, chronic obstructive pulmonary disease and asthma. Besides that, global VOC profiles were investigated. A needle trap device (NTD) was used as pre-concentration technique, associated to gas chromatography-mass spectrometry (GC-MS) analysis. Univariate and multivariate approaches were applied to assess VOC distributions according to the studied diseases. Limits of quantitation ranged from 0.003 to 6.21 ppbv and calculated relative standard deviations did not exceed 10%. At least 15 of the quantified targets presented themselves as discriminating features. A random forest (RF) method was performed in order to classify enrolled conditions according to VOCs' latent patterns, considering VOCs responses in global profiles. The developed model was based on 12 discriminating features and provided overall balanced accuracy of 85.7%. Ultimately, multinomial logistic regression (MLR) analysis was conducted using the concentration of the nine most discriminative targets (2-propanol, 3-methylpentane, (E)-ocimene, limonene, m-cymene, benzonitrile, undecane, terpineol, phenol) as input and provided an average overall accuracy of 95.5% for multiclass prediction.
Collapse
Affiliation(s)
- Fernanda Monedeiro
- Interdisciplinary Centre of Modern Technologies, Nicolaus Copernicus University in Toruń, 4 Wileńska St., 87-100 Toruń, Poland; (F.M.); (M.M.-M.); (I.-A.R.); (B.B.)
| | - Maciej Monedeiro-Milanowski
- Interdisciplinary Centre of Modern Technologies, Nicolaus Copernicus University in Toruń, 4 Wileńska St., 87-100 Toruń, Poland; (F.M.); (M.M.-M.); (I.-A.R.); (B.B.)
| | - Ileana-Andreea Ratiu
- Interdisciplinary Centre of Modern Technologies, Nicolaus Copernicus University in Toruń, 4 Wileńska St., 87-100 Toruń, Poland; (F.M.); (M.M.-M.); (I.-A.R.); (B.B.)
- “Raluca Ripan” Institute for Research in Chemistry, Babeş-Bolyai University, 30 Fântânele St., RO-400294 Cluj-Napoca, Romania
- Department of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarina St., 87-100 Toruń, Poland
| | - Beata Brożek
- Department of Lung Diseases, Provincial Polyclinic Hospital in Toruń, 4 Krasińskiego St., 87-100 Toruń, Poland;
| | - Tomasz Ligor
- Interdisciplinary Centre of Modern Technologies, Nicolaus Copernicus University in Toruń, 4 Wileńska St., 87-100 Toruń, Poland; (F.M.); (M.M.-M.); (I.-A.R.); (B.B.)
- Department of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarina St., 87-100 Toruń, Poland
- Correspondence: ; Tel.: +48-(56)-665-60-58
| | - Bogusław Buszewski
- Interdisciplinary Centre of Modern Technologies, Nicolaus Copernicus University in Toruń, 4 Wileńska St., 87-100 Toruń, Poland; (F.M.); (M.M.-M.); (I.-A.R.); (B.B.)
- Department of Environmental Chemistry and Bioanalytics, Faculty of Chemistry, Nicolaus Copernicus University in Toruń, 7 Gagarina St., 87-100 Toruń, Poland
| |
Collapse
|
39
|
Liu L, Li W, He Z, Chen W, Liu H, Chen K, Pi X. Detection of lung cancer with electronic nose using a novel ensemble learning framework. J Breath Res 2021; 15. [PMID: 33578407 DOI: 10.1088/1752-7163/abe5c9] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Accepted: 02/12/2021] [Indexed: 02/02/2023]
Abstract
Breath analysis based on electronic nose (e-nose) is a promising new technology for the detection of lung cancer that is non-invasive, simple to operate and cost-effective. Lung cancer screening by e-nose relies on predictive models established using machine learning methods. However, using only a single machine learning method to detect lung cancer has some disadvantages, including low detection accuracy and high false negative rate. To address these problems, groups of individual learning models with excellent performance were selected from classic models, including Support Vector Machine, Decision Tree, Random Forest, Logistic Regression and K-nearest neighbor regression, to build an ensemble learning framework (PCA-SVE). The output result of the PCA-SVE framework was obtained by voting. To test this approach, we analyzed 214 breath samples measured by e-nose with 11 gas sensors of four types using the proposed PCA-SVE framework. Experimental results indicated that the accuracy, sensitivity, and specificity of the proposed framework were 95.75%, 94.78%, and 96.96%, respectively. This framework overcomes the disadvantages of a single model, thereby providing an improved, practical alternative for exhaled breath analysis by e-nose.
Collapse
Affiliation(s)
- Lei Liu
- Key Laboratory of Biotechnology Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, Chongqing, P.R. China, Chongqing, Chongqing, 400044, CHINA
| | - Wang Li
- School of Pharmacy and Bioengineering, Chongqing University of Technology, No.174 Shazhengjie, Shapingba, Chongqing, Chongqing, 400044, CHINA
| | - ZiChun He
- Chongqing Red Cross Hospital (People's Hospital of Jiangbei District), Chongqing Red Cross Hospital, 168 Hai'er Rd, Chongqing, 400020 , CHINA
| | - Weimin Chen
- Kunming University, No.727 South Jingming Rd, Chenggong District, Kunming, Yunnan, 650500, CHINA
| | - Hongying Liu
- Key Laboratory of Biotechnology Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University, No.174 Shazhengjie, Shapingba, Chongqing, Chongqing, 400044, CHINA
| | - Ke Chen
- Key Laboratory of Biotechnology Science and Technology, Ministry of Education, College of Bioengineering, , Chongqing University, No.174 Shazhengjie, Shapingba, Chongqing, Chongqing, 400044, CHINA
| | - Xitian Pi
- Key Laboratory of Biotechnology Science and Technology, Ministry of Education, College of Bioengineering, , Chongqing University, No.174 Shazhengjie, Shapingba, Chongqing, Chongqing, 400044, CHINA
| |
Collapse
|
40
|
Bobak CA, Kang L, Workman L, Bateman L, Khan MS, Prins M, May L, Franchina FA, Baard C, Nicol MP, Zar HJ, Hill JE. Breath can discriminate tuberculosis from other lower respiratory illness in children. Sci Rep 2021; 11:2704. [PMID: 33526828 PMCID: PMC7851130 DOI: 10.1038/s41598-021-80970-w] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Accepted: 12/28/2020] [Indexed: 01/30/2023] Open
Abstract
Pediatric tuberculosis (TB) remains a global health crisis. Despite progress, pediatric patients remain difficult to diagnose, with approximately half of all childhood TB patients lacking bacterial confirmation. In this pilot study (n = 31), we identify a 4-compound breathprint and subsequent machine learning model that accurately classifies children with confirmed TB (n = 10) from children with another lower respiratory tract infection (LRTI) (n = 10) with a sensitivity of 80% and specificity of 100% observed across cross validation folds. Importantly, we demonstrate that the breathprint identified an additional nine of eleven patients who had unconfirmed clinical TB and whose symptoms improved while treated for TB. While more work is necessary to validate the utility of using patient breath to diagnose pediatric TB, it shows promise as a triage instrument or paired as part of an aggregate diagnostic scheme.
Collapse
Affiliation(s)
- Carly A. Bobak
- grid.254880.30000 0001 2179 2404Thayer School of Engineering, Dartmouth College, Hanover, NH USA ,grid.254880.30000 0001 2179 2404Geisel School of Medicine, Dartmouth College, Hanover, NH USA
| | - Lili Kang
- grid.254880.30000 0001 2179 2404Thayer School of Engineering, Dartmouth College, Hanover, NH USA
| | - Lesley Workman
- grid.415742.10000 0001 2296 3850Department of Pediatrics and Child Health, MRC Unit on Child and Adolescent Health, University of Cape Town and Red Cross War Memorial Children’s Hospital, Cape Town, South Africa
| | - Lindy Bateman
- grid.415742.10000 0001 2296 3850Department of Pediatrics and Child Health, MRC Unit on Child and Adolescent Health, University of Cape Town and Red Cross War Memorial Children’s Hospital, Cape Town, South Africa
| | - Mohammad S. Khan
- grid.254880.30000 0001 2179 2404Thayer School of Engineering, Dartmouth College, Hanover, NH USA
| | - Margaretha Prins
- grid.415742.10000 0001 2296 3850Department of Pediatrics and Child Health, MRC Unit on Child and Adolescent Health, University of Cape Town and Red Cross War Memorial Children’s Hospital, Cape Town, South Africa
| | - Lloyd May
- grid.254880.30000 0001 2179 2404Thayer School of Engineering, Dartmouth College, Hanover, NH USA
| | - Flavio A. Franchina
- grid.254880.30000 0001 2179 2404Thayer School of Engineering, Dartmouth College, Hanover, NH USA ,grid.4861.b0000 0001 0805 7253Molecular Systems, Organic and Biological Analytical Chemistry Group, University of Liège, Liège, Belgium
| | - Cynthia Baard
- grid.415742.10000 0001 2296 3850Department of Pediatrics and Child Health, MRC Unit on Child and Adolescent Health, University of Cape Town and Red Cross War Memorial Children’s Hospital, Cape Town, South Africa
| | - Mark P. Nicol
- grid.7836.a0000 0004 1937 1151Division of Medical Microbiology and Institute for Infectious Diseases and Molecular Medicine, University of Cape Town, Cape Town, South Africa ,grid.1012.20000 0004 1936 7910School of Biomedical Sciences, University of Western Australia, Perth, Australia
| | - Heather J. Zar
- grid.415742.10000 0001 2296 3850Department of Pediatrics and Child Health, MRC Unit on Child and Adolescent Health, University of Cape Town and Red Cross War Memorial Children’s Hospital, Cape Town, South Africa
| | - Jane E. Hill
- grid.254880.30000 0001 2179 2404Thayer School of Engineering, Dartmouth College, Hanover, NH USA
| |
Collapse
|
41
|
Tozlu BH, Şimşek C, Aydemir O, Karavelioglu Y. A High performance electronic nose system for the recognition of myocardial infarction and coronary artery diseases. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2020.102247] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
42
|
Lammers A, van Bragt J, Brinkman P, Neerincx A, Bos L, Vijverberg S, Maitland-van der Zee A. Breathomics in Chronic Airway Diseases. SYSTEMS MEDICINE 2021. [DOI: 10.1016/b978-0-12-801238-3.11589-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
43
|
Zhong W, Zhang X, Zeng Y, Lin D, Wu J. Recent applications and strategies in nanotechnology for lung diseases. NANO RESEARCH 2021; 14:2067-2089. [PMID: 33456721 PMCID: PMC7796694 DOI: 10.1007/s12274-020-3180-3] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 10/11/2020] [Accepted: 10/11/2020] [Indexed: 05/14/2023]
Abstract
Lung diseases, including COVID-19 and lung cancers, is a huge threat to human health. However, for the treatment and diagnosis of various lung diseases, such as pneumonia, asthma, cancer, and pulmonary tuberculosis, are becoming increasingly challenging. Currently, several types of treatments and/or diagnostic methods are used to treat lung diseases; however, the occurrence of adverse reactions to chemotherapy, drug-resistant bacteria, side effects that can be significantly toxic, and poor drug delivery necessitates the development of more promising treatments. Nanotechnology, as an emerging technology, has been extensively studied in medicine. Several studies have shown that nano-delivery systems can significantly enhance the targeting of drug delivery. When compared to traditional delivery methods, several nanoparticle delivery strategies are used to improve the detection methods and drug treatment efficacy. Transporting nanoparticles to the lungs, loading appropriate therapeutic drugs, and the incorporation of intelligent functions to overcome various lung barriers have broad prospects as they can aid in locating target tissues and can enhance the therapeutic effect while minimizing systemic side effects. In addition, as a new and highly contagious respiratory infection disease, COVID-19 is spreading worldwide. However, there is no specific drug for COVID-19. Clinical trials are being conducted in several countries to develop antiviral drugs or vaccines. In recent years, nanotechnology has provided a feasible platform for improving the diagnosis and treatment of diseases, nanotechnology-based strategies may have broad prospects in the diagnosis and treatment of COVID-19. This article reviews the latest developments in nanotechnology drug delivery strategies in the lungs in recent years and studies the clinical application value of nanomedicine in the drug delivery strategy pertaining to the lung.
Collapse
Affiliation(s)
- Wenhao Zhong
- Department of Hematology, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, 518107 China
| | - Xinyu Zhang
- Department of Hematology, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, 518107 China
| | - Yunxin Zeng
- Department of Hematology, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, 518107 China
| | - Dongjun Lin
- Department of Hematology, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, 518107 China
| | - Jun Wu
- Department of Hematology, The Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, 518107 China
- Key Laboratory of Sensing Technology and Biomedical Instrument of Guangdong Province, School of Biomedical Engineering, Sun Yat-sen University, Guangzhou, 510006 China
| |
Collapse
|
44
|
Mule NM, Patil DD, Kaur M. A comprehensive survey on investigation techniques of exhaled breath (EB) for diagnosis of diseases in human body. INFORMATICS IN MEDICINE UNLOCKED 2021. [DOI: 10.1016/j.imu.2021.100715] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023] Open
|
45
|
Volatile Organic Compounds in Exhaled Breath as Fingerprints of Lung Cancer, Asthma and COPD. J Clin Med 2020; 10:jcm10010032. [PMID: 33374433 PMCID: PMC7796324 DOI: 10.3390/jcm10010032] [Citation(s) in RCA: 53] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 12/14/2020] [Accepted: 12/22/2020] [Indexed: 12/11/2022] Open
Abstract
Lung cancer, chronic obstructive pulmonary disease (COPD) and asthma are inflammatory diseases that have risen worldwide, posing a major public health issue, encompassing not only physical and psychological morbidity and mortality, but also incurring significant societal costs. The leading cause of death worldwide by cancer is that of the lung, which, in large part, is a result of the disease often not being detected until a late stage. Although COPD and asthma are conditions with considerably lower mortality, they are extremely distressful to people and involve high healthcare overheads. Moreover, for these diseases, diagnostic methods are not only costly but are also invasive, thereby adding to people’s stress. It has been appreciated for many decades that the analysis of trace volatile organic compounds (VOCs) in exhaled breath could potentially provide cheaper, rapid, and non-invasive screening procedures to diagnose and monitor the above diseases of the lung. However, after decades of research associated with breath biomarker discovery, no breath VOC tests are clinically available. Reasons for this include the little consensus as to which breath volatiles (or pattern of volatiles) can be used to discriminate people with lung diseases, and our limited understanding of the biological origin of the identified VOCs. Lung disease diagnosis using breath VOCs is challenging. Nevertheless, the numerous studies of breath volatiles and lung disease provide guidance as to what volatiles need further investigation for use in differential diagnosis, highlight the urgent need for non-invasive clinical breath tests, illustrate the way forward for future studies, and provide significant guidance to achieve the goal of developing non-invasive diagnostic tests for lung disease. This review provides an overview of these issues from evaluating key studies that have been undertaken in the years 2010–2019, in order to present objective and comprehensive updated information that presents the progress that has been made in this field. The potential of this approach is highlighted, while strengths, weaknesses, opportunities, and threats are discussed. This review will be of interest to chemists, biologists, medical doctors and researchers involved in the development of analytical instruments for breath diagnosis.
Collapse
|
46
|
Potential of the Electronic Nose for the Detection of Respiratory Diseases with and without Infection. Int J Mol Sci 2020; 21:ijms21249416. [PMID: 33321951 PMCID: PMC7763696 DOI: 10.3390/ijms21249416] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2020] [Revised: 11/16/2020] [Accepted: 11/23/2020] [Indexed: 02/06/2023] Open
Abstract
Respiratory tract infections are common, and when affecting the lower airways and lungs, can result in significant morbidity and mortality. There is an unfilled need for simple, non-invasive tools that can be used to screen for such infections at the clinical point of care. The electronic nose (eNose) is a novel technology that detects volatile organic compounds (VOCs). Early studies have shown that certain diseases and infections can result in characteristic changes in VOC profiles in the exhaled breath. This review summarizes current knowledge on breath analysis by the electronic nose and its potential for the detection of respiratory diseases with and without infection.
Collapse
|
47
|
Wilkinson M, White IR, Hamshere K, Holz O, Schuchardt S, Bellagambi FG, Lomonaco T, Biagini D, Di Francesco F, Fowler SJ. The peppermint breath test: a benchmarking protocol for breath sampling and analysis using GC-MS. J Breath Res 2020; 15. [PMID: 33302258 DOI: 10.1088/1752-7163/abd28c] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Accepted: 12/10/2020] [Indexed: 11/11/2022]
Abstract
Exhaled breath contains hundreds of volatile organic compounds (VOCs) which offers the potential for diagnosing and monitoring a wide range of diseases. As the breath research field has grown, sampling and analytical practices have become highly varied between groups. Standardisation would allow meta-analyses of data from multiple studies and greater confidence in published results. The Peppermint Consortium has been formed to address this task of standardisation. In the current study we aimed to generate initial benchmark values for thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) analysis of breath samples containing peppermint-derived VOCs. Headspace analysis of peppermint oil capsules was performed to determine compounds of interest. Ten healthy participants were recruited by three groups. Each participant provided a baseline breath sample prior to taking a peppermint capsule, with further samples collected at 60, 90, 165, 285 and 360 min following ingestion. Sampling and analytical protocols were different for each institution, in line with their usual practice. Samples were analysed by TD-GC-MS and benchmarking values determined for the time taken for detected peppermint VOCs to return to baseline values. Sixteen compounds were identified in the capsule headspace. Additionally, 2,3-dehydro-1,8-cineole was uniquely found in the breath samples, with a washout profile that suggested it was a product of peppermint metabolism. Five compounds (α-pinene, β-pinene, eucalyptol, menthol and menthone) were quantified by all three groups. Differences in recovery were observed between the groups, particularly for menthone and menthol. The average time taken for VOCs to return to baseline was selected as the benchmark and were 441, 648, 1736, 643 and 375 min for α-pinene, β-pinene, eucalyptol, menthone and menthol respectively. An initial set of easy-to-measure benchmarking values for assessing the performance of TD-GC-MS systems for the analysis of VOCs in breath is presented. These values will be updated when more groups provide additional data.
Collapse
Affiliation(s)
- Maxim Wilkinson
- Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Iain R White
- Laboratory of Environmental and Life Sciences, University of Nova Gorica, Nova Gorica, 5000, SLOVENIA
| | - Katie Hamshere
- Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Olaf Holz
- Member of the German Center for Lung Research (BREATH), Fraunhofer Institute for Toxicology and Experimental Medicine ITEM, Hannover, GERMANY
| | - Sven Schuchardt
- Member of the German Center for Lung Research (BREATH), Fraunhofer-Institut fur Toxikologie und Experimentelle Medizin, Hannover, GERMANY
| | - Francesca G Bellagambi
- Institut des Sciences Analytiques, Université Claude Bernard Lyon 1, 5, rue de la Doua, Villeurbanne, FRANCE, 69100, FRANCE
| | - Tommaso Lomonaco
- Universita degli Studi di Pisa Dipartimento di Chimica e Chimica Industriale, Pisa, ITALY
| | - Denise Biagini
- Universita degli Studi di Pisa Dipartimento di Chimica e Chimica Industriale, Pisa, ITALY
| | - Fabio Di Francesco
- Universita degli Studi di Pisa Dipartimento di Chimica e Chimica Industriale, Pisa, ITALY
| | - Stephen J Fowler
- Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| |
Collapse
|
48
|
Peltrini R, Cordell R, Ibrahim W, Wilde M, Salman D, Singapuri A, Hargadon B, Brightling CE, Thomas CLP, Monks P, Siddiqui S. Volatile organic compounds in a headspace sampling system and asthmatics sputum samples. J Breath Res 2020; 15. [PMID: 33227714 DOI: 10.1088/1752-7163/abcd2a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Accepted: 11/23/2020] [Indexed: 12/17/2022]
Abstract
Background:The headspace of a biological sample contains exogenous VOCs present within the sampling environment which represent the background signal.Study aims:This study aimed to characterise the background signal generated from a headspace sampling system in a clinical site, to evaluate intra- and inter-day variation of background VOC and to understand the impact of a sample itself upon commonly reported background VOC using sputum headspace samples from severe asthmatics.Methods:The headspace, in absence of a biological sample, was collected hourly from 11am to 3pm within a day (time of clinical samples acquisition), and from Monday to Friday in a week, and analysed by thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). Chemometric analysis identified 1120 features, 37 of which were present in at least the 80% of all the samples. The analyses of intra- and inter-day background variations were performed on thirteen of the most abundant features, ubiquitously present in headspace samples. The concentration ratios relative to background were reported for the selected abundant VOC in 36 asthmatic sputum samples, acquired from 36 stable severe asthma patients recruited at Glenfield Hospital, Leicester, UK.Results:The results identified no significant intra- or inter-day variations in compounds levels and no systematic bias of z-scores, with the exclusion of benzothiazole, whose abundance increased linearly between 11am and 3pm with a maximal intra-day fold change of 2.13. Many of the identified background features are reported in literature as components of headspace of biological samples and are considered potential biomarkers for several diseases. The selected background features were identified in headspace of all severe asthma sputum samples, albeit with varying levels of enrichment relative to background.Conclusion:Our observations support the need to consider the background signal derived from the headspace sampling system when developing and validating headspace biomarker signatures using clinical samples.
Collapse
Affiliation(s)
- Rosa Peltrini
- University of Leicester College of Life Sciences, Leicester, LE1 9HN, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Rebecca Cordell
- Chemistry department, University of Leicester, Leicester, Leicestershire, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Wadah Ibrahim
- University of Leicester College of Life Sciences, Leicester, Leicester, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Michael Wilde
- Chemistry department, University of Leicester, Leicester, Leicestershire, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Dahlia Salman
- Chemistry, Loughborough University School of Science, Loughborough, LE11 3TU, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Amisha Singapuri
- University of Leicester, Leicester, Leicestershire, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Beverley Hargadon
- University of Leicester, Leicester, Leicestershire, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Christopher E Brightling
- University of Leicester, Leicester, Leicestershire, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - C L Paul Thomas
- Department of Chemistry, Centre for Analytical Science, Loughborough University School of Science, LOUGHBOROUGH, Leicestershire, LE11 3TU, Loughborough, LE11 3TU, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Paul Monks
- Chemistry department, University of Leicester, Leicester, Leicestershire, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Salman Siddiqui
- University of Leicester College of Life Sciences, Leicester, Leicester, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| |
Collapse
|
49
|
Holden KA, Ibrahim W, Salman D, Cordell R, McNally T, Patel B, Phillips R, Beardsmore C, Wilde M, Bryant L, Singapuri A, Monks P, Brightling C, Greening N, Thomas P, Siddiqui S, Gaillard EA. Use of the ReCIVA device in breath sampling of patients with acute breathlessness: a feasibility study. ERJ Open Res 2020; 6:00119-2020. [PMID: 33263021 PMCID: PMC7680907 DOI: 10.1183/23120541.00119-2020] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2020] [Accepted: 07/17/2020] [Indexed: 01/24/2023] Open
Abstract
Introduction Investigating acute multifactorial undifferentiated breathlessness and understanding the driving inflammatory processes can be technically challenging in both adults and children. Being able to validate noninvasive methods such as breath analysis would be a huge clinical advance. The ReCIVA® device allows breath samples to be collected directly onto sorbent tubes at the bedside for analysis of exhaled volatile organic compounds (eVOCs). We aimed to assess the feasibility of using this device in acutely breathless patients. Methods Adults hospitalised with acute breathlessness and children aged 5–16 years with acute asthma or chronic stable asthma, as well as healthy adult and child volunteers, were recruited. Breath samples were collected onto sorbent tubes using the ReCIVA® device and sent for analysis by means of two-dimensional gas chromatography-mass spectrometry (GCxGC-MS). The NASA Task Load Index (NASA-TLX) was used to assess the perceived task workload of undertaking sampling from the patient's perspective. Results Data were available for 65 adults and 61 children recruited. In total, 98.4% of adults and 75.4% of children were able to provide the full target breath sample using the ReCIVA® device. NASA-TLX measurements were available in the adult population with mean values of 3.37 for effort, 2.34 for frustration, 3.8 for mental demand, 2.8 for performance, 3.9 for physical demand and 2.8 for temporal demand. Discussion This feasibility study demonstrates it is possible and acceptable to collect breath samples from both adults and children at the bedside for breathomics analysis using the ReCIVA® device. It is feasible to collect breath samples for breath analysis at the bedside using the ReCIVA device in acutely breathless adults and childrenhttps://bit.ly/2ZTonWo
Collapse
Affiliation(s)
- Karl A Holden
- NIHR Leicester Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK.,These authors contributed equally
| | - Wadah Ibrahim
- NIHR Leicester Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK.,These authors contributed equally
| | | | | | - Teresa McNally
- NIHR Leicester Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK
| | - Bharti Patel
- NIHR Leicester Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK
| | - Rachael Phillips
- NIHR Leicester Clinical Research Facility, Leicester Royal Infirmary, Leicester, UK
| | - Caroline Beardsmore
- NIHR Leicester Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK
| | - Michael Wilde
- Dept of Chemistry, University of Leicester, Leicester, UK
| | - Luke Bryant
- Dept of Chemistry, University of Leicester, Leicester, UK
| | - Amisha Singapuri
- NIHR Leicester Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK
| | - Paul Monks
- Dept of Chemistry, University of Leicester, Leicester, UK
| | - Chris Brightling
- NIHR Leicester Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK
| | - Neil Greening
- NIHR Leicester Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK
| | - Paul Thomas
- NIHR Leicester Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK
| | - Salman Siddiqui
- NIHR Leicester Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK.,These authors contributed equally
| | - Erol A Gaillard
- NIHR Leicester Biomedical Research Centre (Respiratory Theme), Glenfield Hospital, Leicester, UK.,These authors contributed equally
| |
Collapse
|
50
|
The Role of Electronic Noses in Phenotyping Patients with Chronic Obstructive Pulmonary Disease. BIOSENSORS-BASEL 2020; 10:bios10110171. [PMID: 33187142 PMCID: PMC7697924 DOI: 10.3390/bios10110171] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 11/05/2020] [Accepted: 11/09/2020] [Indexed: 12/12/2022]
Abstract
Chronic obstructive pulmonary disease (COPD) is a common progressive disorder of the respiratory system which is currently the third leading cause of death worldwide. Exhaled breath analysis is a non-invasive method to study lung diseases, and electronic noses have been extensively used in breath research. Studies with electronic noses have proved that the pattern of exhaled volatile organic compounds is different in COPD. More recent investigations have reported that electronic noses could potentially distinguish different endotypes (i.e., neutrophilic vs. eosinophilic) and are able to detect microorganisms in the airways responsible for exacerbations. This article will review the published literature on electronic noses and COPD and help in identifying methodological, physiological, and disease-related factors which could affect the results.
Collapse
|