1
|
Park S, Nam DY, Jeon HJ, Han JH, Jang D, Hwang J, Park YS, Han YG, Choy YB, Lee DY. Chromophoric cerium oxide nanoparticle-loaded sucking disk-type strip sensor for optical measurement of glucose in tear fluid. Biomater Res 2023; 27:135. [PMID: 38111009 PMCID: PMC10729336 DOI: 10.1186/s40824-023-00469-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 11/24/2023] [Indexed: 12/20/2023] Open
Abstract
BACKGROUND Noninvasive monitoring of tear glucose levels can be convenient for patients to manage their diabetes mellitus. However, there are issues with monitoring tear glucose levels, such as the invasiveness of some methods, the miniaturization, inaccuracy, or the high cost of wearable devices. To overcome the issues, we newly designed a sucking disk-type (SD) strip biosensor that can quickly suck tear fluid and contains cerium oxide nanoparticle (CNP) that causes a unique color change according to the glucose level of the tear without complicated electronic components. METHODS The SD strip biosensor composed of three distinct parts (tip, channel, and reaction chamber) was designed to contain the sensing paper, onto which tear fluid can be collected and delivered. The sensing paper treated with CNP/APTS (aminopropyltriethoxysilane) /GOx (glucose oxidase) was characterized. Then we carried out the reliability of the SD strip biosensor in the diabetic rabbit animals. We quantitatively analyzed the color values of the SD strip biosensor through the colorimetric analysis algorithm. RESULTS We contacted the inferior palpebral conjunctiva (IPC) of a diabetic rabbit eye using an SD strip biosensor to collect tears without eye irritation and successfully verified the performance and quantitative efficacy of the sensor. An image processing algorithm that can optimize measurement accuracy is developed for accurate color change measurement of SD strip biosensors. The validation tests show a good correlation between glucose concentrations measured in the tear and blood. CONCLUSION Our findings demonstrate that the CNP-embedded SD strip biosensor and the associated image processing can simply monitor tear glucose to manage diabetes mellitus.
Collapse
Affiliation(s)
- Sijin Park
- Department of Bioengineering, College of Engineering, and BK FOUR Biopharmaceutical Innovation Leader for Education and Research Group, Hanyang University, 222 Wangsimni-Ro Seongdong-Gu, Seoul, 04763, Republic of Korea
| | - Dong Yeon Nam
- College of Engineering, Interdisciplinary Program in Bioengineering, Seoul National University, 1 Gwanak-Ro Gwanak-Gu, Seoul, 08826, Republic of Korea
| | - Hee-Jae Jeon
- Department of Mechanical and Biomedical Engineering, Kangwon National University, 1 Gangwondaehak-Gil, Chuncheon, 24341, Republic of Korea
| | - Jae Hoon Han
- College of Engineering, Interdisciplinary Program in Bioengineering, Seoul National University, 1 Gwanak-Ro Gwanak-Gu, Seoul, 08826, Republic of Korea
| | - Dawon Jang
- Department of Bioengineering, College of Engineering, and BK FOUR Biopharmaceutical Innovation Leader for Education and Research Group, Hanyang University, 222 Wangsimni-Ro Seongdong-Gu, Seoul, 04763, Republic of Korea
| | - Juil Hwang
- Department of Physics, College of Natural Sciences, Hanyang University, 222 Wangsimni-Ro Seongdong-Gu, Seoul, 04763, Republic of Korea
| | - Yeong-Seo Park
- Department of Mechanical and Biomedical Engineering, Kangwon National University, 1 Gangwondaehak-Gil, Chuncheon, 24341, Republic of Korea
| | - Young-Geun Han
- Department of Physics, College of Natural Sciences, Hanyang University, 222 Wangsimni-Ro Seongdong-Gu, Seoul, 04763, Republic of Korea
| | - Young Bin Choy
- College of Engineering, Interdisciplinary Program in Bioengineering, Seoul National University, 1 Gwanak-Ro Gwanak-Gu, Seoul, 08826, Republic of Korea.
- Department of Biomedical Engineering, Seoul National University College of Medicine, 101 Daehak-Ro Jongno-Gu, Seoul, 03080, Republic of Korea.
- Institute of Medical & Biological Engineering, Medical Research Center, Seoul National University, 101 Daehak-Ro Jongno-Gu, Seoul, 03080, Republic of Korea.
| | - Dong Yun Lee
- Department of Bioengineering, College of Engineering, and BK FOUR Biopharmaceutical Innovation Leader for Education and Research Group, Hanyang University, 222 Wangsimni-Ro Seongdong-Gu, Seoul, 04763, Republic of Korea.
- Institute of Nano Science and Technology (INST) and Institute for Bioengineering and Biopharmaceutical Research (IBBR), Hanyang University, 222 Wangsimni-Ro Seongdong-Gu, Seoul, 04763, Republic of Korea.
- Elixir Pharmatech Inc, 222 Wangsimni-Ro Seongdong-Gu, Seoul, 04763, Republic of Korea.
| |
Collapse
|
2
|
Dong S, Zhang N, Yi M, Zhang J, Di D, Deng J, Li L, Hu B. Slug-Flow Microextraction Mass Spectrometry for Enhanced Detection of Analytes in Human Tear Fluids using Noninvasive Microsampling and Nanoelectrospray Ionization via a Capillary. Anal Chem 2023; 95:16054-16058. [PMID: 37852267 DOI: 10.1021/acs.analchem.3c03683] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2023]
Abstract
In vivo noninvasive sampling and sensitive analysis of human tear fluids at the microliter level is an important but challenging task in investigating eye health. In this work, capillary microsampling coupled with slug-flow microextraction mass spectrometry (SFME-MS) was developed for enhanced detection of analytes in human tear fluids. As low as 1.0 μL of human tear fluid could be directly sampled using a capillary, and extraction/spray solvent was then loaded into the capillary to perform slug-flow microextraction and direct nanoelectrospray ionization (nESI) of analytes. All analytical procedures, including tear microsampling, microextraction, and ionization of analytes, were performed using a capillary. Enhanced detection of therapeutic drugs and disease biomarkers in human tear fluids was successfully demonstrated. Acceptable analytical performances including sensitivity, reproducibility, and quantitation were obtained. It is found that the use of SFME could improve the nESI-MS detection of trace analytes over 100-fold that depends on the chemical properties of analytes. Overall, this study showed that SFME-nESI-MS is a highly effective method for enhanced detection of trace analytes in tear fluids and is expected to be a potentially powerful tool in significant biological and clinical applications.
Collapse
Affiliation(s)
- Songbin Dong
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| | - Ning Zhang
- Ophthalmology Department, First Affiliated Hospital of Xi'an Jiaotong University, Xi'an 710064, China
| | - Man Yi
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| | - Jianfeng Zhang
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| | - Dandan Di
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| | - Jiewei Deng
- School of Biomedical and Pharmaceutical Sciences, Smart Medical Innovation Technology Center, Guangdong University of Technology, Guangzhou 510006, China
| | - Lei Li
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| | - Bin Hu
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Guangdong Provincial Key Laboratory of Speed Capability Research, Jinan University, Guangzhou 510632, China
| |
Collapse
|
3
|
Kazanskiy NL, Khonina SN, Butt MA. Smart Contact Lenses-A Step towards Non-Invasive Continuous Eye Health Monitoring. BIOSENSORS 2023; 13:933. [PMID: 37887126 PMCID: PMC10605521 DOI: 10.3390/bios13100933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Revised: 10/10/2023] [Accepted: 10/17/2023] [Indexed: 10/28/2023]
Abstract
According to the age-old adage, while eyes are often considered the gateway to the soul, they might also provide insights into a more pragmatic aspect of our health: blood sugar levels. This potential breakthrough could be realized through the development of smart contact lenses (SCLs). Although contact lenses were first developed for eyesight correction, new uses have recently become available. In the near future, it might be possible to monitor a variety of ocular and systemic disorders using contact lens sensors. Within the realm of glaucoma, SCLs present a novel prospect, offering a potentially superior avenue compared to traditional management techniques. These lenses introduce the possibility of non-invasive and continuous monitoring of intraocular pressure (IOP) while also enabling the personalized administration of medication as and when needed. This convergence holds great promise for advancing glaucoma care. In this review, recent developments in SCLs, including their potential applications, such as IOP and glucose monitoring, are briefly discussed.
Collapse
Affiliation(s)
- Nikolay L. Kazanskiy
- Samara National Research University, 443086 Samara, Russia
- IPSI RAS-Branch of the FSRC “Crystallography and Photonics” RAS, 443001 Samara, Russia
| | - Svetlana N. Khonina
- Samara National Research University, 443086 Samara, Russia
- IPSI RAS-Branch of the FSRC “Crystallography and Photonics” RAS, 443001 Samara, Russia
| | | |
Collapse
|
4
|
Chao C, Lema C, Redfern R, Richdale K. Changes in tear glucose and insulin concentrations following an oral glucose tolerance test. Clin Exp Optom 2023; 106:752-758. [PMID: 35977531 PMCID: PMC11970258 DOI: 10.1080/08164622.2022.2111204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2022] [Revised: 07/15/2022] [Accepted: 08/03/2022] [Indexed: 10/15/2022] Open
Abstract
CLINICAL RELEVANCE Tear glucose and insulin are responsible for the health of the ocular surface; thus, it is important for clinicians to detect the tear glucose and insulin using point-of-care methods. AIM To determine if changes in blood glucose and insulin levels following an oral glucose tolerance test are reflected in the tears and to test the association between gene expression and tear insulin and glucose. METHODS Twenty healthy young adults were enrolled. Basal tears and peripheral blood samples were collected to assess glucose and insulin using a point-of-care glucometer and ELISA assays in fasted subjects, and 1.5 and 3 h after an oral glucose challenge. Conjunctival impression cytology was collected to determine gene expression of insulin receptor (INSR) and glucose transporters (GLUT1 and GLUT4). Changes were examined using non-parametric one-way ANOVA. Spearman tests were conducted to examine associations between variables. RESULTS Glucose and insulin levels increased 1.5 h after oral glucose in both blood (P < 0.001) and tears (P < 0.049) and returned to near baseline values after 3 h. There was a positive correlation between glucose levels in the blood and tears (rho = 0.57, P < 0.001), but not between blood and tear insulin levels (P = 0.18). Glucose and insulin levels in tears were correlated (rho = 0.32, P = 0.048). Tear glucose concentration at 1.5 h after oral glucose was associated with INSR expression (rho = 0.49, P = 0.03), and there was a trend with GLUT1 (P = 0.06) but not GLUT4. CONCLUSION Tear glucose reflected blood glucose levels but this correspondence was not observed for insulin. Further studies are required to determine the role of glucose and insulin on the ocular surface in both health and diabetes.
Collapse
Affiliation(s)
- Cecilia Chao
- College of Optometry, University of Houston, Houston, TX, USA
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Carolina Lema
- College of Optometry, University of Houston, Houston, TX, USA
| | - Rachel Redfern
- College of Optometry, University of Houston, Houston, TX, USA
| | | |
Collapse
|
5
|
Difonzo G, Troilo M, Casiello M, D’Accolti L, Caponio F. Autohydrolysis Application on Vine Shoots and Grape Stalks to Obtain Extracts Enriched in Xylo-Oligosaccharides and Phenolic Compounds. Molecules 2023; 28:3760. [PMID: 37175170 PMCID: PMC10180318 DOI: 10.3390/molecules28093760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 04/21/2023] [Accepted: 04/24/2023] [Indexed: 05/15/2023] Open
Abstract
Agronomic practices and the winemaking process lead to the production of considerable quantities of waste and by-products. These are often considered waste with negative effects on environmental sustainability. However, vine shoots and grape stalks can be reused, representing a potential source of xylo-oligosaccharides and polyphenols. In this context, the purpose of this work was to obtain enriched extracts using three different autohydrolysis treatments with (i) H2O, (ii) H2O:EtOH, and (iii) H2O:Amberlyst. The obtained extracts were characterized by their xylo-oligosaccharide and polyphenol profiles using LC-MS techniques. The use of ethanol during autohydrolysis allowed for greater extraction of xylan-class compounds, especially in vine shoot samples, while an increase in antioxidant activity (128.04 and 425.66 µmol TE/g for ABTS and DPPH, respectively) and in total phenol content (90.92 mg GAE/g) was obtained for grape stalks.
Collapse
Affiliation(s)
- Graziana Difonzo
- Department of Soil, Plant and Food Sciences, University of Bari Aldo Moro, Via Amendola165, 70126 Bari, Italy; (G.D.); (M.T.)
| | - Marica Troilo
- Department of Soil, Plant and Food Sciences, University of Bari Aldo Moro, Via Amendola165, 70126 Bari, Italy; (G.D.); (M.T.)
| | - Michele Casiello
- Chemistry Department, University of Bari Aldo Moro, Via Orabona 4, 70125 Bari, Italy; (M.C.); (L.D.)
| | - Lucia D’Accolti
- Chemistry Department, University of Bari Aldo Moro, Via Orabona 4, 70125 Bari, Italy; (M.C.); (L.D.)
| | - Francesco Caponio
- Department of Soil, Plant and Food Sciences, University of Bari Aldo Moro, Via Amendola165, 70126 Bari, Italy; (G.D.); (M.T.)
| |
Collapse
|
6
|
Alhaddad AY, Aly H, Gad H, Al-Ali A, Sadasivuni KK, Cabibihan JJ, Malik RA. Sense and Learn: Recent Advances in Wearable Sensing and Machine Learning for Blood Glucose Monitoring and Trend-Detection. Front Bioeng Biotechnol 2022; 10:876672. [PMID: 35646863 PMCID: PMC9135106 DOI: 10.3389/fbioe.2022.876672] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Accepted: 04/12/2022] [Indexed: 12/12/2022] Open
Abstract
Diabetes mellitus is characterized by elevated blood glucose levels, however patients with diabetes may also develop hypoglycemia due to treatment. There is an increasing demand for non-invasive blood glucose monitoring and trends detection amongst people with diabetes and healthy individuals, especially athletes. Wearable devices and non-invasive sensors for blood glucose monitoring have witnessed considerable advances. This review is an update on recent contributions utilizing novel sensing technologies over the past five years which include electrocardiogram, electromagnetic, bioimpedance, photoplethysmography, and acceleration measures as well as bodily fluid glucose sensors to monitor glucose and trend detection. We also review methods that use machine learning algorithms to predict blood glucose trends, especially for high risk events such as hypoglycemia. Convolutional and recurrent neural networks, support vector machines, and decision trees are examples of such machine learning algorithms. Finally, we address the key limitations and challenges of these studies and provide recommendations for future work.
Collapse
Affiliation(s)
- Ahmad Yaser Alhaddad
- Department of Mechanical and Industrial Engineering, Qatar University, Doha, Qatar
| | - Hussein Aly
- KINDI Center for Computing Research, Qatar University, Doha, Qatar
| | - Hoda Gad
- Weill Cornell Medicine - Qatar, Doha, Qatar
| | - Abdulaziz Al-Ali
- KINDI Center for Computing Research, Qatar University, Doha, Qatar
| | | | - John-John Cabibihan
- Department of Mechanical and Industrial Engineering, Qatar University, Doha, Qatar
| | | |
Collapse
|
7
|
Elsherif M, Moreddu R, Alam F, Salih AE, Ahmed I, Butt H. Wearable Smart Contact Lenses for Continual Glucose Monitoring: A Review. Front Med (Lausanne) 2022; 9:858784. [PMID: 35445050 PMCID: PMC9013844 DOI: 10.3389/fmed.2022.858784] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Accepted: 03/10/2022] [Indexed: 11/15/2022] Open
Abstract
Diabetes mellitus is a chronic disease requiring a careful management to prevent its collateral complications, such as cardiovascular and Alzheimer's diseases, retinopathy, nephropathy, foot and hearing impairment, and neuropathy. Self-monitoring of blood glucose at point-of-care settings is an established practice for diabetic patients. However, current technologies for glucose monitoring are invasive, costly, and only provide single snapshots for a widely varying parameter. On the other hand, tears are a source of physiological information that mirror the health state of an individual by expressing different concentrations of metabolites, enzymes, vitamins, salts, and proteins. Therefore, the eyes may be exploited as a sensing site with substantial diagnostic potential. Contact lens sensors represent a viable route for targeting minimally-invasive monitoring of disease onset and progression. Particularly, glucose concentration in tears may be used as a surrogate to estimate blood glucose levels. Extensive research efforts recently have been devoted to develop smart contact lenses for continual glucose detection. The latest advances in the field are reviewed herein. Sensing technologies are described, compared, and the associated challenges are critically discussed.
Collapse
Affiliation(s)
- Mohamed Elsherif
- Department of Mechanical Engineering, Khalifa University of Science and Engineering, Abu Dhabi, United Arab Emirates
- *Correspondence: Mohamed Elsherif
| | | | - Fahad Alam
- Department of Mechanical Engineering, Khalifa University of Science and Engineering, Abu Dhabi, United Arab Emirates
| | - Ahmed E. Salih
- Department of Mechanical Engineering, Khalifa University of Science and Engineering, Abu Dhabi, United Arab Emirates
| | - Israr Ahmed
- Department of Mechanical Engineering, Khalifa University of Science and Engineering, Abu Dhabi, United Arab Emirates
| | - Haider Butt
- Department of Mechanical Engineering, Khalifa University of Science and Engineering, Abu Dhabi, United Arab Emirates
- Haider Butt
| |
Collapse
|
8
|
Lee E, Kang S, Shim J, Jeong D, Jeong Y, Ahn J, Seo K. Quantification of tear glucose levels and their correlation with blood glucose levels in dogs. Vet Med Sci 2022; 8:1816-1824. [PMID: 35305285 PMCID: PMC9297779 DOI: 10.1002/vms3.788] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Background No previous studies have quantified tear glucose (TG) levels in dogs or compared changes in TG and blood glucose (BG) concentrations. Objective To quantify TG concentration and evaluate its correlation with BG level in dogs. Methods Twenty repetitive tests were performed in alternate eyes of four dogs, with a minimum washout period of 1 week. Tears and blood were collected at 30‐min intervals with successive glucose injections (1 g/kg) every 30 min. Cross‐correlations of BG and TG levels were assessed. The delay and association between TG and corresponding BG levels were analysed for each dog; samples were collected at 5‐min intervals. The tears were collected using microcapillary tubes. Collected tears and blood were analysed for glucose concentration using a colorimetric assay and commercially available glucometer, respectively. Results The average baseline BG and TG levels were 4.76 ± 0.58 and 0.39 ± 0.04 mmol/L, respectively. Even with highly fluctuating BG levels, a significant cross‐correlation coefficient (r = 0.86, p < 0.05) was observed between changes of BG and TG levels. The delay time between BG and TG levels was 10 min. On average, BG levels were 16.34 times higher than TG levels. There was strong correlation between BG and TG levels (rs = 0.80, p < 0.01). Significant differences in TG concentrations between normoglycaemia, mild hyperglycaemia, and severe hyperglycaemia were found (p < 0.05). Conclusions Canine TG concentrations have not been quantified previously. Our findings suggest preliminary data for future research on TG levels in dogs and show TG measurement could be used to screen for diabetes mellitus in dogs.
Collapse
Affiliation(s)
- Eunji Lee
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul, Korea
| | - Seonmi Kang
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul, Korea
| | - Jaeho Shim
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul, Korea
| | - Dajeong Jeong
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul, Korea
| | - Youngseok Jeong
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul, Korea
| | - Junyeong Ahn
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul, Korea
| | - Kangmoon Seo
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul, Korea
| |
Collapse
|
9
|
Adigal SS, Rizvi A, Rayaroth NV, John RV, Barik A, Bhandari S, George SD, Lukose J, Kartha VB, Chidangil S. Human tear fluid analysis for clinical applications: progress and prospects. Expert Rev Mol Diagn 2021; 21:767-787. [PMID: 34115952 DOI: 10.1080/14737159.2021.1941879] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Introduction: Human blood and saliva are increasingly under investigation for the detection of biomarkers for early diagnosis of non-communicable (e.g.cancers) and communicable diseases like COVID-19. Exploring the potential application of human tears, an easily accessible body fluid, for the diagnosis of various diseases is the need of the hour.Areas covered: This review deals with a comprehensive account of applications of tear analysis using different techniques, their comparison and overall progress achieved till now. The techniques used for tear fluid analysis are HPLC/UPLC/SDS-PAGE, CE, etc., together with ELISA, Mass Spectrometry, etc. But, with advances in instrumentation and data processing methods, it has become easy to couple the various separation methods with highly sensitive optical techniques for the analysis of body fluids.Expert opinion: Tear analysis can provide valuable information about the health condition of the eyes since it contains several molecular constituents, and their relative concentrations may alter under abnormal conditions. Tear analysis has the advantage that it is totally non-invasive. This study recommends tear fluid as a reliable clinical sample to be probed by highly sensitive optical techniques to diagnose different health conditions, with special emphasis on eye diseases.
Collapse
Affiliation(s)
- Sphurti S Adigal
- Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Alisha Rizvi
- Department of Ophthalmology, Kasthurba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Nidheesh V Rayaroth
- Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Reena V John
- Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Ajayakumar Barik
- Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Sulatha Bhandari
- Department of Ophthalmology, Kasthurba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Sajan D George
- Centre for Applied Nanotechnology, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Jijo Lukose
- Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Vasudevan B Kartha
- Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India
| | - Santhosh Chidangil
- Centre of Excellence for Biophotonics, Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, Karnataka, India
| |
Collapse
|
10
|
Metabolomics comparison of cord and peripheral blood-derived serum eye drops for the treatment of dry eye disease. Transfus Apher Sci 2021; 60:103155. [PMID: 33975808 DOI: 10.1016/j.transci.2021.103155] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Revised: 04/28/2021] [Accepted: 05/03/2021] [Indexed: 11/23/2022]
Abstract
Allogeneic peripheral blood-derived (PBS) serum eye drops have been largely used in the treatment of dry eye disease (DED). Recently, cord blood has emerged as an effective alternative serum source (cord blood serum, CBS), containing a higher amount of growth factors than PBS, it holds the promise of a better capability to stimulate corneal healing. However, the lack of a standardized method for preparation, dispensation, storage and a poor biochemical characterization still hamper the establishment of a clinical consensus. Here the metabolomes of the two different serum eye drop preparations were compared using proton nuclear magnetic resonance spectroscopy. We found that both PBS and CBS contained several organic compounds, the majority of them already detected in human tears and may be thereby considered lacrimal substitutes. Metabolites having in the multivariate statistical analysis Partial least squares discriminant analysis (PLS-DA) a VIP scores > 1.0 were considered to be significantly different. All the metabolites identified were found to have a p < 0.05 in the univariate analysis. CBS, in particular, showed the highest amount of choline, myo-inositol, glutamine, creatine and β-hydroxybutyrate. These evidences constitute relevant advances towards serum eye drops characterization and confirm that cord blood is a valid alternative source of serum eye drops.
Collapse
|
11
|
Joda BA, Ward NI. Use of human teardrop fluid for the determination of trace elements in healthy individuals and diabetic patients. J Trace Elem Med Biol 2021; 65:126733. [PMID: 33607356 DOI: 10.1016/j.jtemb.2021.126733] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2020] [Revised: 12/11/2020] [Accepted: 02/08/2021] [Indexed: 01/16/2023]
Abstract
BACKGROUND The use of unconventional biological materials in human trace element studies has increased in terms of published research studies. The aim of present study was to develop and validate the use of teardrop fluid for determining trace element levels in the human body. No study has been published in this area yet. This is a new non-invasive approach in the possible early diagnosis of the pathogenesis of type 2 diabetes. MATERIALS AND METHODS Human teardrop fluid samples were obtained from Karbala (Iraq) (n = 111) healthy individuals and with type 2 diabetes (n = 44); and London (UK) healthy individuals (n = 18). The levels of V, Cr, Mn, Fe, Cu, Zn, As, Sr and Cd were determined using an inductively coupled plasma mass equipped with collision cell technology for polyatomic ion correction (ICP-MS). STATISTICAL ANALYSIS Discriminate function analysis (DFA) was carried out to determine the set of variables that discriminated between the trace elements in teardrop fluid samples from healthy individuals and diabetic patients. RESULTS The trace element levels of human teardrop fluid are similar for many elements to that reported for human blood serum in the literature. This is interesting since they have different physiological functions, although overall they are mainly water containing electrolytes (∼ 90 %) and solids (antibodies, hormones, etc). In general, for the study groups in Karbala, Iraq, significantly higher teardrop fluid levels of Mn and Sr were found in type 2 diabetic patients when compared with healthy individuals (evaluated using an F-test and a two-tailed t-test). The levels of V, Cu and As were found to be significantly higher (P < 0.05) in healthy individuals than type 2 diabetic patients. Although the levels of Fe and Zn were slightly higher in type 2 diabetic patients than healthy cases, the differences were not statistically significant (P > 0.05). Cr and Cd were found to have similar levels for both study groups. Significantly higher teardrop fluid levels of V, Cr, Mn, Fe, Zn, As and Sr were found in healthy individuals from Karbala (Iraq) when compared with those from London (UK). In contrast, the levels of Cd observed to be significantly higher in London (UK) than Karbala. No statistical difference was found for Cu between the two healthy groups. STATISTICAL ANALYSIS Discriminate analysis showed that human teardrop fluid V, Mn, Zn, As, Sr and Cd levels could be used to discriminate between healthy and type 2 diabetes study groups in Karbala, Iraq (83 % of cases correctly classified). CONCLUSION The use of human teardrop fluid for determining the trace element levels of human health conditions has been evaluated. Trace elemental levels are like that for blood serum which is widely used as an invasive method for assessing human health conditions. Sample collection for teardrop fluid is non-invasive and the application has potential for determining the trace element levels in healthy individuals and disorder conditions (like type 2 diabetes) in countries where cultural and gender sensitivity are issues with respect to the collection methods used for other body fluid samples.
Collapse
Affiliation(s)
- Baker A Joda
- Department of Chemistry, Faculty of Science, University of Kerbala, Karbala, Iraq.
| | - Neil I Ward
- ICP-MS Facility, Department of Chemistry, Faculty of Engineering and Physical Sciences, Guildford, Surrey, GU2 7XH, UK.
| |
Collapse
|
12
|
Sung WH, Tsao YT, Shen CJ, Tsai CY, Cheng CM. Small-volume detection: platform developments for clinically-relevant applications. J Nanobiotechnology 2021; 19:114. [PMID: 33882955 PMCID: PMC8058587 DOI: 10.1186/s12951-021-00852-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 04/07/2021] [Indexed: 12/16/2022] Open
Abstract
Biochemical analysis of human body fluids is a frequent and fruitful strategy for disease diagnosis. Point-of-care (POC) diagnostics offers the tantalizing possibility of providing rapid diagnostic results in non-laboratory settings. Successful diagnostic testing using body fluids has been reported on in the literature; however, small-volume detection devices, which offer remarkable advantages such as portability, inexpensiveness, capacity for mass production, and tiny sample volume requirements have not been thoroughly discussed. Here, we review progress in this research field, with a focus on developments since 2015. In this review article, we provide a summary of articles that have detailed the development of small-volume detection strategies using clinical samples over the course of the last 5 years. Topics covered include small-volume detection strategies in ophthalmology, dermatology or plastic surgery, otolaryngology, and cerebrospinal fluid analysis. In ophthalmology, advances in technology could be applied to examine tear or anterior chamber (AC) fluid for glucose, lactoferrin, interferon, or VEGF. These approaches could impact detection and care for diseases including diabetic mellitus, dry-eye disease, and age-related maculopathy. Early detection and easy monitoring are critical approaches for improving overall care and outcome. In dermatology or plastic surgery, small-volume detection strategies have been applied for passive or interactive wound dressing, wound healing monitoring, and blister fluid analysis for autoimmune disease diagnosis. In otolaryngology, the analysis of nasal secretions and mucosa could be used to differentiate between allergic responses and infectious diseases. Cerebrospinal fluid analysis could be applied in neurodegenerative diseases, central neural system infection and tumor diagnosis. Other small-volume fluids that have been analyzed for diagnostic and monitoring purposes include semen and cervico-vaginal fluids. We include more details regarding each of these fluids, associated collection and detection devices, and approaches in our review.
Collapse
Affiliation(s)
- Wei-Hsuan Sung
- Chang Gung Memorial Hospital, Linkou Medical Center and Chang Gung Medical College and Chang Gung University, Taoyuan, Taiwan
| | - Yu-Ting Tsao
- Chang Gung Memorial Hospital, Linkou Medical Center and Chang Gung Medical College and Chang Gung University, Taoyuan, Taiwan
| | - Ching-Ju Shen
- Department of Obstetrics and Gynecology, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan
| | - Chia-Ying Tsai
- Department of Ophthalmology, Fu Jen Catholic University Hospital, Fu Jen Catholic University, New Taipei City, Taiwan.
- School of Medicine, College of Medicine, Fu Jen Catholic University, New Taipei City, Taiwan.
| | - Chao-Min Cheng
- Institute of Biomedical Engineering, National Tsing Hua University, Hsinchu, Taiwan.
| |
Collapse
|
13
|
Shin H, Seo H, Chung WG, Joo BJ, Jang J, Park JU. Recent progress on wearable point-of-care devices for ocular systems. LAB ON A CHIP 2021; 21:1269-1286. [PMID: 33704299 DOI: 10.1039/d0lc01317j] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
The eye is a complex sensory organ that contains abundant information for specific diseases and pathological responses. It has emerged as a facile biological interface for wearable healthcare platforms because of its excellent accessibility. Recent advances in electronic devices have led to the extensive research of point-of-care (POC) systems for diagnosing and monitoring diseases by detecting the biomarkers within the eye. Among these systems, contact lenses, which make direct contact with the ocular surfaces, have been utilized as one of the promising candidates for non-invasive POC testing of various diseases. The continuous and long-term measurement from the sensor allows the patients to manage their symptoms in an effective and convenient way. Herein, we review the progress of contact lens sensors in terms of the materials, methodologies, device designs, and target biomarkers. The anatomical structure and biological mechanisms of the eye are also discussed to provide a comprehensive understanding of the principles of contact lens sensors. Intraocular pressure and glucose, which are the representative biomarkers found in the eyes, can be measured with the biosensors integrated with contact lenses for the diagnosis of glaucoma and diabetes. Furthermore, contact lens sensors for various general pathologies as well as other ocular diseases are also considered, thereby providing the prospects for further developments of smart contact lenses as a future POC system.
Collapse
Affiliation(s)
- Haein Shin
- Nano Science Technology Institute, Department of Materials Science and Engineering, Yonsei University, Seoul, 03722, Republic of Korea.
| | | | | | | | | | | |
Collapse
|
14
|
Li P, Lee GH, Kim SY, Kwon SY, Kim HR, Park S. From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices. ACS NANO 2021; 15:1960-2004. [PMID: 33534541 DOI: 10.1021/acsnano.0c06688] [Citation(s) in RCA: 144] [Impact Index Per Article: 36.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Patient-friendly medical diagnostics and treatments have been receiving a great deal of interest due to their rapid and cost-effective health care applications with minimized risk of infection, which has the potential to replace conventional hospital-based medical procedures. In particular, the integration of recently developed materials into health care devices allows the rapid development of point-of-care (POC) sensing platforms and implantable devices with special functionalities. In this review, the recent advances in biosensors for patient-friendly diagnosis and implantable devices for patient-friendly treatment are discussed. Comprehensive analysis of portable and wearable biosensing platforms for patient-friendly health monitoring and disease diagnosis is provided, including topics such as materials selection, device structure and integration, and biomarker detection strategies. Moreover, specific challenges related to each biological fluid for wearable biosensor-based POC applications are presented. Also, advances in implantable devices, including recent materials development and wireless communication strategies, are discussed. Furthermore, various patient-friendly surgical and treatment approaches are reviewed, such as minimally invasive insertion and mounting, in vivo electrical and optical modulations, and post-operation health monitoring. Finally, the challenges and future perspectives toward the development of the patient-friendly diagnosis and treatment are provided.
Collapse
Affiliation(s)
- Pei Li
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
| | - Gun-Hee Lee
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
| | - Su Yeong Kim
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
| | - Se Young Kwon
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
| | - Hyung-Ryong Kim
- College of Dentistry and Institute of Tissue Regeneration Engineering (ITREN), Dankook University, Cheonan 330-714, Republic of Korea
| | - Steve Park
- Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea
| |
Collapse
|
15
|
Paria D, Convertino A, Mussi V, Maiolo L, Barman I. Silver-Coated Disordered Silicon Nanowires Provide Highly Sensitive Label-Free Glycated Albumin Detection through Molecular Trapping and Plasmonic Hotspot Formation. Adv Healthc Mater 2021; 10:e2001110. [PMID: 33236490 DOI: 10.1002/adhm.202001110] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2020] [Revised: 11/08/2020] [Indexed: 12/21/2022]
Abstract
Glycated albumin (GA) is rapidly emerging as a robust biomarker for screening and monitoring of diabetes. To facilitate its rapid, point-of-care measurements, a label-free surface-enhanced Raman spectroscopy (SERS) sensing platform is reported that leverages the specificity of molecular vibrations and signal amplification on silver-coated silicon nanowires (Ag/SiNWs) for highly sensitive and reproducible quantification of GA. The simulations and experimental measurements demonstrate that the disordered orientation of the nanowires coupled with the wicking of the analyte molecules during the process of solvent evaporation facilitates molecular trapping at the generated plasmonic hotspots. Highly sensitive detection of glycated albumin is shown with the ability to visually detect spectral features at as low as 500 × 10-9 m, significantly below the physiological range of GA in body fluids. Combined with chemometric regression models, the spectral data recorded on the Ag/SiNWs also allow accurate prediction of glycated concentration in mixtures of glycated and non-glycated albumin in proportions that reflect those in the bloodstream.
Collapse
Affiliation(s)
- Debadrita Paria
- Department of Mechanical Engineering Johns Hopkins University Baltimore MD 21218 USA
| | - Annalisa Convertino
- Instituto per la Microelettronica e i Microsistemi Consiglio Nazionale delle Ricerche Roma 00133 Italy
| | - Valentina Mussi
- Instituto per la Microelettronica e i Microsistemi Consiglio Nazionale delle Ricerche Roma 00133 Italy
| | - Luca Maiolo
- Instituto per la Microelettronica e i Microsistemi Consiglio Nazionale delle Ricerche Roma 00133 Italy
| | - Ishan Barman
- Department of Mechanical Engineering Johns Hopkins University Baltimore MD 21218 USA
- Department of Oncology Johns Hopkins University School of Medicine Baltimore MD 21218 USA
- Department of Radiology & Radiological Science Johns Hopkins University School of Medicine Baltimore MD 21218 USA
| |
Collapse
|
16
|
Aihara M, Kubota N, Minami T, Shirakawa R, Sakurai Y, Hayashi T, Iwamoto M, Takamoto I, Kubota T, Suzuki R, Usami S, Jinnouchi H, Aihara M, Yamauchi T, Sakata T, Kadowaki T. Association between tear and blood glucose concentrations: Random intercept model adjusted with confounders in tear samples negative for occult blood. J Diabetes Investig 2021; 12:266-276. [PMID: 32621777 PMCID: PMC7858102 DOI: 10.1111/jdi.13344] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Revised: 06/10/2020] [Accepted: 06/25/2020] [Indexed: 12/26/2022] Open
Abstract
AIMS/INTRODUCTION To prevent diabetic complications, strict glucose control and frequent monitoring of blood glucose levels with invasive methods are necessary. We considered the monitoring of tear glucose levels might be a possible method for non-invasive glucose monitoring. To develop tear glucose monitoring for clinical application, we investigated the precise correlation between the blood and tear glucose concentrations. MATERIALS AND METHODS A total of 10 participants and 20 participants with diabetes were admitted, and blood and tear samples were collected. Before statistical analysis, we eliminated tear samples contaminated with blood. We observed the daily blood and tear glucose dynamics, and carried out a random intercept model analysis to examine the association between the blood and tear glucose concentrations. RESULTS Tear occult blood tests showed that the tear glucose concentrations and their variation increased in both participants with and without diabetes as contamination of blood increased. In both participants with and without diabetes, fluctuations of the plasma glucose concentrations were observed depending on the timing of collection of the samples, and the dynamics of the tear glucose concentrations paralleled those of the plasma glucose concentrations. The random intercept model analysis showed a significant association between the plasma and tear glucose concentrations in participants with diabetes (P < 0.001). This association still existed even after adjusting for the glycated hemoglobin levels and the prandial state (P < 0.001). CONCLUSIONS It is important to eliminate the tear samples contaminated with blood. Tear glucose monitoring might be a reliable and non-invasive substitute method for monitoring the blood glucose concentrations for diabetes patients, irrespective of glycated hemoglobin levels and timing of sample collection.
Collapse
Affiliation(s)
- Masakazu Aihara
- Department of Diabetes and Metabolic DiseasesGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Naoto Kubota
- Department of Diabetes and Metabolic DiseasesGraduate School of MedicineThe University of TokyoTokyoJapan
- Department of Clinical Nutrition TherapyThe University of TokyoTokyoJapan
- Clinical Nutrition ProgramNational Institute of Health and NutritionTokyoJapan
- Laboratory for Metabolic HomeostasisRIKEN Center for Integrative Medical SciencesKanagawaJapan
| | - Takahiro Minami
- Department of OphthalmologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Rika Shirakawa
- Department of OphthalmologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Yoshitaka Sakurai
- Department of Diabetes and Metabolic DiseasesGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Takanori Hayashi
- Department of Diabetes and Metabolic DiseasesGraduate School of MedicineThe University of TokyoTokyoJapan
- Clinical Nutrition ProgramNational Institute of Health and NutritionTokyoJapan
| | - Masahiko Iwamoto
- Department of Diabetes and Metabolic DiseasesGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Iseki Takamoto
- Department of Diabetes and Metabolic DiseasesGraduate School of MedicineThe University of TokyoTokyoJapan
- Department of Diabetes and EndocrinologyNerima Hikarigaoka HospitalTokyoJapan
| | - Tetsuya Kubota
- Department of Diabetes and Metabolic DiseasesGraduate School of MedicineThe University of TokyoTokyoJapan
- Clinical Nutrition ProgramNational Institute of Health and NutritionTokyoJapan
- Laboratory for Metabolic HomeostasisRIKEN Center for Integrative Medical SciencesKanagawaJapan
- Analysis Tool Development GroupIntestinal Microbiota ProjectKanagawa Institute of Industrial Science and TechnologyKanagawaJapan
- Division of Cardiovascular MedicineToho University Ohashi Medical CenterTokyoJapan
| | - Ryo Suzuki
- Department of Diabetes and Metabolic DiseasesGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Satoshi Usami
- Graduate School of EducationThe University of TokyoTokyoJapan
| | | | - Makoto Aihara
- Department of OphthalmologyGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Toshimasa Yamauchi
- Department of Diabetes and Metabolic DiseasesGraduate School of MedicineThe University of TokyoTokyoJapan
| | - Toshiya Sakata
- Department of Materials Science and EngineeringGraduate School of EngineeringThe University of TokyoTokyoJapan
- Provigate IncTokyoJapan
| | - Takashi Kadowaki
- Department of Diabetes and Metabolic DiseasesGraduate School of MedicineThe University of TokyoTokyoJapan
- Department of Prevention of Diabetes and Lifestyle‐Related DiseasesGraduate School of MedicineThe University of TokyoTokyoJapan
- Department of Metabolism and NutritionFaculty of MedicineMizonokuchi HospitalTeikyo UniversityKanagawaJapan
| |
Collapse
|
17
|
Han JH, Cho YC, Koh WG, Choy YB. Preocular sensor system for concurrent monitoring of glucose levels and dry eye syndrome using tear fluids. PLoS One 2020; 15:e0239317. [PMID: 33027299 PMCID: PMC7540859 DOI: 10.1371/journal.pone.0239317] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Accepted: 09/03/2020] [Indexed: 12/21/2022] Open
Abstract
The present study demonstrated a noninvasive preocular sensor system for the concurrent monitoring of diabetes and one of its prevalent complications, dry eye syndrome (DES), using tear fluids. Two distinct sensors, i.e., the glucose and DES sensors, were prepared and encased together in a single housing unit to produce the sensor system, and the tip was designed to be in contact with the eye surface noninvasively to collect and deliver tear fluid to the sensors. The glucose sensor was modified from a commercially available electrochemical sensor to allow for the measurement of glucose concentrations, even in a small amount of collected tear fluid. The DES sensor was equipped with a microchannel spaced with two parallel electrodes to determine the amount of collected tear fluid. In vivo experimental results revealed that with the collected tear fluid of about 0.6–1.0 μl, the sensor system estimated the blood glucose concentrations with acceptable accuracy compared with that of the glucometer in clinical use. The DES condition in animals was diagnosed with high sensitivity (91.7%) and specificity (83.3%).
Collapse
Affiliation(s)
- Jae Hoon Han
- Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul, Korea
| | - Yong Chan Cho
- Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul, Korea
| | - Won-Gun Koh
- Department of Chemical and Biomolecular Engineering, Yonsei University, Seoul, Korea
| | - Young Bin Choy
- Interdisciplinary Program in Bioengineering, College of Engineering, Seoul National University, Seoul, Korea
- Institute of Medical & Biological Engineering, Medical Research Center, Seoul National University, Seoul, Korea
- Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul, Korea
- * E-mail:
| |
Collapse
|
18
|
Jiang Y, Yang C, Zheng Y, Liu Y, Chen Y. A Set of Global Metabolomic Biomarker Candidates to Predict the Risk of Dry Eye Disease. Front Cell Dev Biol 2020; 8:344. [PMID: 32582687 PMCID: PMC7295093 DOI: 10.3389/fcell.2020.00344] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2020] [Accepted: 04/20/2020] [Indexed: 12/18/2022] Open
Abstract
Purpose We used ultraperformance liquid chromatography coupled with quadrupole/time-of-flight tandem mass spectrometry (UPLC-Q/TOF-MS/MS) to analyze the metabolic profile of reflex tears obtained from patients with dry eye disorders. Methods We performed a cross-sectional study involving 113 subjects: 85 patients diagnosed with dry eye syndrome (dry eye group) and 28 healthy volunteers (control group). Reflex tears (20–30 μl) were collected from the tear meniscus of both eyes of each subject using a Schirmer I test strip. MS data were acquired with a standard workflow by UPLC-Q/TOF-MS/MS. Metabolites were quantitatively analyzed and matched with entries in the Metlin, Massbank, and HMDB databases. Least absolute shrinkage and selection operator (LASSO) regression was conducted to detect important metabolites. Multiple logistic regression was used to identify the significant metabolic biomarker candidates for dry eye syndrome. Open database sources, including the Kyoto Encyclopedia of Genes and Genomes and MetaboAnalyst, were used to identify metabolic pathways. Results After the LASSO regression and multiple logistic regression analysis, 4 of 20 metabolic biomarker candidates were significantly correlated with Ocular Surface Disease Index score, 42 of 57 with fluorescein breakup time, and 26 of 57 with fluorescein staining. By focusing on the overlap of these three sets, 48 of 51 metabolites contributed to the incidence of dry eye and there were obvious changes in different age groups. Metabolic pathway analysis revealed that the main pathways were glucose metabolism, amino acid metabolism, and glutathione metabolism. Conclusion Dry eye syndrome induces changes in the metabolic profile of tears, and the trend differs with age. This evidence reveals the relationship between changes in metabolites, symptoms of dry eye syndrome, and age.
Collapse
Affiliation(s)
- Yaping Jiang
- Department of Ophthalmology, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China
| | - Chuanxi Yang
- Department of Cardiology, Jiangsu Province Hospital, Medical School of Southeast University, Nanjing, China
| | - Yuxiang Zheng
- Yangpu Daqiao Community Health Service Center, Shanghai, China
| | - Yining Liu
- Institute of Plant Physiology and Ecology, Shanghai Institutes for Biological Sciences, Shanghai, China
| | - Yihui Chen
- Department of Ophthalmology, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China
| |
Collapse
|
19
|
Yao YN, Di D, Yuan ZC, Wu L, Hu B. Schirmer Paper Noninvasive Microsampling for Direct Mass Spectrometry Analysis of Human Tears. Anal Chem 2020; 92:6207-6212. [PMID: 32250596 DOI: 10.1021/acs.analchem.9b05078] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Rapid and sensitive detection of metabolites and chemical residues in human tears is highly beneficial for understanding eye health. In this study, Schirmer paper was used for noninvasive microsampling of human tears, and then paper spray mass spectrometry (PSMS) was performed for direct analysis of human tears. Schirmer PSMS was successfully used for rapid diagnosis of dry-eye syndrome by detecting the volume and metabolites of human tears. Drugs of abuse, therapeutic drugs, and pharmacodynamics in human tears were also investigated by Schirmer PSMS. Furthermore, specific markers of environmental exposures in the air to human eyes, including volatile organic compounds, aerosol, and smoke, were unambiguously sampled and detected in human tears using Schirmer PSMS. Excellent analytical performances were achieved, including single-use, low-sample consumption (1.0 μL), rapid analysis (the whole analytical procedure completed within 3 min), high sensitivity (absolute limit of detection less than or equal to 0.5 pg, signal-to-noise ratio greater than or equal to 3), good reproducibility (relative standard deviation less than 10%, n = 3), and accurate quantitation (average deviation less than 3%, n = 3). Overall, our results showed that Schirmer PSMS is a highly effective method for direct tear analysis and is expected to be a convenient tool for human tear analysis in significant clinical applications.
Collapse
Affiliation(s)
- Ya-Nan Yao
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| | - Dandan Di
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| | - Zi-Cheng Yuan
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| | - Lin Wu
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| | - Bin Hu
- Institute of Mass Spectrometry and Atmospheric Environment, Guangdong Provincial Engineering Research Center for On-line Source Apportionment System of Air Pollution, Jinan University, Guangzhou 510632, China
| |
Collapse
|
20
|
Zou R, Shan S, Huang L, Chen Z, Lawson T, Lin M, Yan L, Liu Y. High-Performance Intraocular Biosensors from Chitosan-Functionalized Nitrogen-Containing Graphene for the Detection of Glucose. ACS Biomater Sci Eng 2019; 6:673-679. [DOI: 10.1021/acsbiomaterials.9b01149] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Ruitao Zou
- Laboratory of Nanoscale Biosensing and Bioimaging, School of Ophthalmology and Optometry, School of Biomedical Engineering, Wenzhou Medical University, 270 Xueyuanxi Road, Wenzhou, Zhejiang 325027, China
- State Key Laboratory of Ophthalmology, Optometry, and Vision Science, Wenzhou Medical University, Wenzhou, Zhejiang 325027, China
| | - Suyan Shan
- Laboratory of Nanoscale Biosensing and Bioimaging, School of Ophthalmology and Optometry, School of Biomedical Engineering, Wenzhou Medical University, 270 Xueyuanxi Road, Wenzhou, Zhejiang 325027, China
- State Key Laboratory of Ophthalmology, Optometry, and Vision Science, Wenzhou Medical University, Wenzhou, Zhejiang 325027, China
| | - Libin Huang
- Laboratory of Nanoscale Biosensing and Bioimaging, School of Ophthalmology and Optometry, School of Biomedical Engineering, Wenzhou Medical University, 270 Xueyuanxi Road, Wenzhou, Zhejiang 325027, China
- State Key Laboratory of Ophthalmology, Optometry, and Vision Science, Wenzhou Medical University, Wenzhou, Zhejiang 325027, China
| | - Zhi Chen
- ARC Centre of Excellence for Electromaterials Science, Intelligent Polymer Research Institute, AIIM Facility, University of Wollongong, Squires Way, Wollongong, New South Wales 2522, Australia
| | - Tom Lawson
- ARC Centre of Excellence for Nanoscale Biophotonics (CNBP), Department of Physics and Astronomy, Macquarie University, 7 Wally’s Walk, Sydney, New South Wales 2109, Australia
| | - Mimi Lin
- Laboratory of Nanoscale Biosensing and Bioimaging, School of Ophthalmology and Optometry, School of Biomedical Engineering, Wenzhou Medical University, 270 Xueyuanxi Road, Wenzhou, Zhejiang 325027, China
- State Key Laboratory of Ophthalmology, Optometry, and Vision Science, Wenzhou Medical University, Wenzhou, Zhejiang 325027, China
| | - Lu Yan
- Laboratory of Nanoscale Biosensing and Bioimaging, School of Ophthalmology and Optometry, School of Biomedical Engineering, Wenzhou Medical University, 270 Xueyuanxi Road, Wenzhou, Zhejiang 325027, China
- State Key Laboratory of Ophthalmology, Optometry, and Vision Science, Wenzhou Medical University, Wenzhou, Zhejiang 325027, China
| | - Yong Liu
- Laboratory of Nanoscale Biosensing and Bioimaging, School of Ophthalmology and Optometry, School of Biomedical Engineering, Wenzhou Medical University, 270 Xueyuanxi Road, Wenzhou, Zhejiang 325027, China
- State Key Laboratory of Ophthalmology, Optometry, and Vision Science, Wenzhou Medical University, Wenzhou, Zhejiang 325027, China
| |
Collapse
|
21
|
Yazdani M, Elgstøen KBP, Rootwelt H, Shahdadfar A, Utheim ØA, Utheim TP. Tear Metabolomics in Dry Eye Disease: A Review. Int J Mol Sci 2019; 20:E3755. [PMID: 31374809 PMCID: PMC6695908 DOI: 10.3390/ijms20153755] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Revised: 07/26/2019] [Accepted: 07/30/2019] [Indexed: 12/13/2022] Open
Abstract
Dry eye disease (DED) is a multifactorial syndrome that can be caused by alteration in the quality or quantity of the precorneal tear film. It is considered one of the most common ocular conditions leading patients to seek eye care. The current method for diagnostic evaluations and follow-up examinations of DED is a combination of clinical signs and symptoms determined by clinical tests and questionnaires, respectively. The application of powerful omics technologies has opened new avenues toward analysis of subjects in health and disease. Metabolomics is a new emerging and complementary research discipline to all modern omics in the comprehensive analysis of biological systems. The identification of distinct metabolites and integrated metabolic profiles in patients can potentially inform clinicians at an early stage or during monitoring of disease progression, enhancing diagnosis, prognosis, and the choice of therapy. In ophthalmology, metabolomics has gained considerable attention over the past decade but very limited such studies have been reported on DED. This paper aims to review the application of tear metabolomics in DED.
Collapse
Affiliation(s)
- Mazyar Yazdani
- Department of Medical Biochemistry, Oslo University Hospital, Ullevål, 0450 Oslo, Norway.
- Center for Eye Research, Department of Ophthalmology, Oslo University Hospital, Ullevål, 0450 Oslo, Norway.
- The Norwegian Dry Eye Clinic, 0366 Oslo, Norway.
| | | | - Helge Rootwelt
- Department of Medical Biochemistry, Oslo University Hospital, 0027 Oslo, Norway
| | - Aboulghassem Shahdadfar
- Center for Eye Research, Department of Ophthalmology, Oslo University Hospital, Ullevål, 0450 Oslo, Norway
| | | | - Tor Paaske Utheim
- Department of Medical Biochemistry, Oslo University Hospital, Ullevål, 0450 Oslo, Norway
- The Norwegian Dry Eye Clinic, 0366 Oslo, Norway
- Department of Plastic and Reconstructive Surgery, Oslo University Hospital, 0450 Oslo, Norway
- Department of Maxillofacial Surgery, Oslo University Hospital, 0450 Oslo, Norway
- Department of Ophthalmology, Vestre Viken Hospital Trust, 3019 Drammen, Norway
- Department of Ophthalmology, Stavanger University Hospital, 4011 Stavanger, Norway
- Department of Clinical Medicine, Faculty of Medicine, University of Bergen, 5020 Bergen, Norway
- Department of Ophthalmology, Sørlandet Hospital Arendal, 4604 Arendal, Norway
- Department of Life Sciences and Health, Oslo Metropolitan University, 0130 Oslo, Norway
| |
Collapse
|
22
|
Sempionatto JR, Brazaca LC, García-Carmona L, Bolat G, Campbell AS, Martin A, Tang G, Shah R, Mishra RK, Kim J, Zucolotto V, Escarpa A, Wang J. Eyeglasses-based tear biosensing system: Non-invasive detection of alcohol, vitamins and glucose. Biosens Bioelectron 2019; 137:161-170. [PMID: 31096082 PMCID: PMC8372769 DOI: 10.1016/j.bios.2019.04.058] [Citation(s) in RCA: 136] [Impact Index Per Article: 22.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2019] [Revised: 04/26/2019] [Accepted: 04/30/2019] [Indexed: 01/15/2023]
Abstract
We report on a wearable tear bioelectronic platform, integrating a microfluidic electrochemical detector into an eyeglasses nose-bridge pad, for non-invasive monitoring of key tear biomarkers. The alcohol-oxidase (AOx) biosensing fluidic system allowed real-time tear collection and direct alcohol measurements in stimulated tears, leading to the first wearable platform for tear alcohol monitoring. Placed outside the eye region this fully wearable tear-sensing platform addresses drawbacks of sensor systems involving direct contact with the eye as the contact lenses platform. Integrating the wireless electronic circuitry into the eyeglasses frame thus yielded a fully portable, convenient-to-use fashionable sensing device. The tear alcohol sensing concept was demonstrated for monitoring of alcohol intake in human subjects over multiple drinking courses, displaying good correlation to parallel BAC measurements. We also demonstrate for the first time the ability to monitor tear glucose outside the eye and the utility of wearable devices for monitoring vitamin nutrients in connection to enzymatic flow detector and rapid voltammetric scanning, respectively. These developments pave the way to build an effective eyeglasses system capable of chemical tear analysis.
Collapse
Affiliation(s)
- Juliane R Sempionatto
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, United States
| | - Laís Canniatti Brazaca
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, United States; Sao Carlos Physics Institute, University of Sao Paulo, Sao Carlos, 13566-590, Sao Paulo, Brazil
| | - Laura García-Carmona
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, United States; Department of Analytical Chemistry, University of Alcalá, 28871, Alcalá de Henares, Spain
| | - Gulcin Bolat
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, United States
| | - Alan S Campbell
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, United States
| | - Aida Martin
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, United States
| | - Guangda Tang
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, United States
| | - Rushabh Shah
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, United States
| | - Rupesh K Mishra
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, United States
| | - Jayoung Kim
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, United States
| | - Valtencir Zucolotto
- Sao Carlos Physics Institute, University of Sao Paulo, Sao Carlos, 13566-590, Sao Paulo, Brazil
| | - Alberto Escarpa
- Department of Analytical Chemistry, University of Alcalá, 28871, Alcalá de Henares, Spain
| | - Joseph Wang
- Department of NanoEngineering, University of California, San Diego, La Jolla, CA, 92093, United States.
| |
Collapse
|
23
|
Noninvasive Self-diagnostic Device for Tear Collection and Glucose Measurement. Sci Rep 2019; 9:4747. [PMID: 30894582 PMCID: PMC6427043 DOI: 10.1038/s41598-019-41066-8] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Accepted: 02/28/2019] [Indexed: 01/01/2023] Open
Abstract
We propose a noninvasive, self-diagnostic device that enables safe tear collection and glucose measurement. The device described herein was manufactured by tight assembly of a lid for tear collection in conjunction with a strip-type glucose sensor. The lid was designed to be in contact with the inferior palpebral conjunctiva for tear collection and was thus designed to possess a proper contact area and rounded boundaries to avoid eye tissue damage. For the strip-type glucose sensor, we employed a commercially available electrochemical sensor (Accu-Chek test strips), which was modified to reduce the volume of the reaction chamber (0.4 μl) for a small amount of collected tear fluid. When tested with in vivo animal models, the device was able to collect tear fluid in a relatively short time (<2 s) without causing eye tissue damage, and the device allowed the collected tear fluid to be delivered to the sensor for measurement of tear glucose concentrations. The blood glucose concentrations estimated with the tear glucose concentrations obtained with the device exhibited a high correlation with those actually measured with a clinically available glucometer (R2 = 0.9617).
Collapse
|
24
|
Wang X, Gericke A, Ackermann M, Wang S, Neufurth M, Schröder HC, Pfeiffer N, Müller WEG. Polyphosphate, the physiological metabolic fuel for corneal cells: a potential biomaterial for ocular surface repair. Biomater Sci 2019; 7:5506-5515. [DOI: 10.1039/c9bm01289c] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Polyphosphate, a natural inorganic polymer that acts as a reservoir for metabolic fuel (ATP), increases the proliferation and migration potency of epithelial cells, covering the avascular cornea.
Collapse
Affiliation(s)
- Xiaohong Wang
- ERC Advanced Investigator Grant Research Group at the Institute for Physiological Chemistry
- University Medical Center of the Johannes Gutenberg University
- 55128 Mainz
- Germany
| | - Adrian Gericke
- Department of Ophthalmology
- University Medical Center of the Johannes Gutenberg-University Mainz
- 55131 Mainz
- Germany
| | - Maximilian Ackermann
- Institute of Functional and Clinical Anatomy
- University Medical Center of the Johannes Gutenberg University
- 55099 Mainz
- Germany
| | - Shunfeng Wang
- ERC Advanced Investigator Grant Research Group at the Institute for Physiological Chemistry
- University Medical Center of the Johannes Gutenberg University
- 55128 Mainz
- Germany
| | - Meik Neufurth
- ERC Advanced Investigator Grant Research Group at the Institute for Physiological Chemistry
- University Medical Center of the Johannes Gutenberg University
- 55128 Mainz
- Germany
| | - Heinz C. Schröder
- ERC Advanced Investigator Grant Research Group at the Institute for Physiological Chemistry
- University Medical Center of the Johannes Gutenberg University
- 55128 Mainz
- Germany
| | - Norbert Pfeiffer
- Department of Ophthalmology
- University Medical Center of the Johannes Gutenberg-University Mainz
- 55131 Mainz
- Germany
| | - Werner E. G. Müller
- ERC Advanced Investigator Grant Research Group at the Institute for Physiological Chemistry
- University Medical Center of the Johannes Gutenberg University
- 55128 Mainz
- Germany
| |
Collapse
|
25
|
Tseng RC, Chen CC, Hsu SM, Chuang HS. Contact-Lens Biosensors. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2651. [PMID: 30104496 PMCID: PMC6111605 DOI: 10.3390/s18082651] [Citation(s) in RCA: 62] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Revised: 08/06/2018] [Accepted: 08/10/2018] [Indexed: 12/14/2022]
Abstract
Rapid diagnosis and screening of diseases have become increasingly important in predictive and preventive medicine as they improve patient treatment strategies and reduce cost as well as burden on our healthcare system. In this regard, wearable devices are emerging as effective and reliable point-of-care diagnostics that can allow users to monitor their health at home. These wrist-worn, head-mounted, smart-textile, or smart-patches devices can offer valuable information on the conditions of patients as a non-invasive form of monitoring. However, they are significantly limited in monitoring physiological signals and biomechanics, and, mostly, rely on the physical attributes. Recently, developed wearable devices utilize body fluids, such as sweat, saliva, or skin interstitial fluid, and electrochemical interactions to allow continuous physiological condition and disease monitoring for users. Among them, tear fluid has been widely utilized in the investigation of ocular diseases, diabetes, and even cancers, because of its easy accessibility, lower complexity, and minimal invasiveness. By determining the concentration change of analytes within the tear fluid, it would be possible to identify disease progression and allow patient-oriented therapies. Considering the emerging trend of tear-based biosensing technology, this review article aims to focus on an overview of the tear fluid as a detection medium for certain diseases, such as ocular disorders, diabetes, and cancer. In addition, the rise and application of minimally invasive detection and monitoring via integrated contact lens biosensors will also be addressed, in regards to their practicality and current developmental progress.
Collapse
Affiliation(s)
- Ryan Chang Tseng
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan.
| | - Ching-Chuen Chen
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan.
| | - Sheng-Min Hsu
- Department of Ophthalmology, National Cheng Kung University Hospital, Tainan City 704, Taiwan.
| | - Han-Sheng Chuang
- Department of Biomedical Engineering, National Cheng Kung University, Tainan City 701, Taiwan.
- Medical Device Innovation Center, National Cheng Kung University, Tainan City 701, Taiwan.
| |
Collapse
|
26
|
Jiang N, Montelongo Y, Butt H, Yetisen AK. Microfluidic Contact Lenses. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2018; 14:e1704363. [PMID: 29521022 PMCID: PMC6607692 DOI: 10.1002/smll.201704363] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Indexed: 05/24/2023]
Abstract
Contact lens is a ubiquitous technology used for vision correction and cosmetics. Sensing in contact lenses has emerged as a potential platform for minimally invasive point-of-care diagnostics. Here, a microlithography method is developed to fabricate microconcavities and microchannels in a hydrogel-based contact lens via a combination of laser patterning and embedded templating. Optical microlithography parameters influencing the formation of microconcavities including ablation power (4.3 W) and beam speed (50 mm s-1 ) are optimized to control the microconcavity depth (100 µm) and diameter (1.5 mm). The fiber templating method allows the production of microchannels having a diameter range of 100-150 µm. Leak-proof microchannel and microconcavity connections in contact lenses are validated through flow testing of artificial tear containing fluorescent microbeads (Ø = 1-2 µm). The microconcavities of contact lenses are functionalized with multiplexed fluorophores (2 µL) to demonstrate optical excitation and emission capability within the visible spectrum. The fabricated microfluidic contact lenses may have applications in ophthalmic monitoring of metabolic disorders at point-of-care settings and controlled drug release for therapeutics.
Collapse
Affiliation(s)
- Nan Jiang
- School of Engineering and Applied SciencesHarvard UniversityCambridgeMA02138USA
| | - Yunuen Montelongo
- Department of ChemistryImperial College LondonSouth Kensington CampusLondonSW7 2AZUK
- Universidad De La Salle BajíoLeón37150Mexico
| | - Haider Butt
- Nanotechnology LaboratorySchool of EngineeringUniversity of BirminghamEdgbastonBirminghamB15 2TTUK
| | - Ali K. Yetisen
- Institute for Measurement Systems and Sensor TechnologyTechnische Universität MünchenTheresienstrasse 9080333MunichGermany
- School of Chemical EngineeringUniversity of BirminghamEdgbastonBirminghamB15 2TTUK
- Institute of Translational MedicineMindelsohn Way, EdgbastonBirminghamB15 2THUK
| |
Collapse
|
27
|
Abstract
The members of the Tear Film Subcommittee reviewed the role of the tear film in dry eye disease (DED). The Subcommittee reviewed biophysical and biochemical aspects of tears and how these change in DED. Clinically, DED is characterized by loss of tear volume, more rapid breakup of the tear film and increased evaporation of tears from the ocular surface. The tear film is composed of many substances including lipids, proteins, mucins and electrolytes. All of these contribute to the integrity of the tear film but exactly how they interact is still an area of active research. Tear film osmolarity increases in DED. Changes to other components such as proteins and mucins can be used as biomarkers for DED. The Subcommittee recommended areas for future research to advance our understanding of the tear film and how this changes with DED. The final report was written after review by all Subcommittee members and the entire TFOS DEWS II membership.
Collapse
|
28
|
Inoue Y, Inoue M, Saito M, Yoshikawa H, Tamiya E. Sensitive Detection of Glycated Albumin in Human Serum Albumin Using Electrochemiluminescence. Anal Chem 2017; 89:5909-5915. [DOI: 10.1021/acs.analchem.7b00280] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Yuki Inoue
- Department
of Applied Physics, Graduate School of Engineering, Osaka University, 2-1,
Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Mikako Inoue
- Department
of Pharmacology and Toxicology, Faculty of Arts and Sciences, University of Toronto, 27 King’s College Circle, Toronto, Ontario M5S 1A1, Canada
| | - Masato Saito
- Department
of Applied Physics, Graduate School of Engineering, Osaka University, 2-1,
Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Hiroyuki Yoshikawa
- Department
of Applied Physics, Graduate School of Engineering, Osaka University, 2-1,
Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Eiichi Tamiya
- Department
of Applied Physics, Graduate School of Engineering, Osaka University, 2-1,
Yamadaoka, Suita, Osaka 565-0871, Japan
| |
Collapse
|
29
|
Gabriel EFM, Garcia PT, Lopes FM, Coltro WKT. Paper-Based Colorimetric Biosensor for Tear Glucose Measurements. MICROMACHINES 2017. [PMCID: PMC6189872 DOI: 10.3390/mi8040104] [Citation(s) in RCA: 59] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
This paper describes a paper-based colorimetric biosensor for measuring glucose concentration levels in human tear samples. Colorimetric biosensors were wax printed on paper platforms and modified with chitosan previously prepared in acetic acid. The proposed device was explored to measure the glucose levels in human tear samples using 3,3′,5,5′-tetramethylbenzydine (TMB) as the chromogenic reagent. The paper-based colorimetric biosensor exhibited a linear behavior for the glucose concentration range between 0.1 and 1.0 mM. The achieved analytical sensitivity and limit of detection (LOD) were 84 AU/mM and 50 µM, respectively. Moreover, the device provided analytical reliability and no statistical difference when compared to the data recorded with a commercial glucometer. The proof-of-concept of our device was successfully demonstrated by measuring the glucose levels in six tear samples from nondiabetic subjects. In general, the results showed that the colorimetric biosensor has noticeable potential to be used as a powerful tool for tear glucose monitoring, since this fluid offers lower potential interferences, non-invasive sample collection and is pain-free. Furthermore, the proposed device could facilitate the treatment of diabetic patients who need constant control of glucose levels and cannot tolerate multiple finger sticks per day.
Collapse
Affiliation(s)
| | - Paulo Tarso Garcia
- Instituto de Química, Universidade Federal de Goiás, 74690-900 Goiânia, GO, Brazil; (E.F.M.G.); (P.T.G.)
| | - Flavio Marques Lopes
- Faculdade de Farmácia, Universidade Federal de Goiás, 74605-170 Goiânia, GO, Brazil;
| | - Wendell Karlos Tomazelli Coltro
- Instituto de Química, Universidade Federal de Goiás, 74690-900 Goiânia, GO, Brazil; (E.F.M.G.); (P.T.G.)
- Instituto Nacional de Ciência e Tecnologia em Bioanalítica (INCTBio), 13083-970 Campinas, SP, Brazil
- Correspondence: ; Tel.: +55-62-3521-1127
| |
Collapse
|
30
|
Ruan JL, Chen C, Shen JH, Zhao XL, Qian SH, Zhu ZG. A Gelated Colloidal Crystal Attached Lens for Noninvasive Continuous Monitoring of Tear Glucose. Polymers (Basel) 2017; 9:polym9040125. [PMID: 30970805 PMCID: PMC6432312 DOI: 10.3390/polym9040125] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Revised: 03/15/2017] [Accepted: 03/23/2017] [Indexed: 01/20/2023] Open
Abstract
Patients of diabetes mellitus urgently need noninvasive and continuous glucose monitoring in daily point-of-care. As the tear glucose concentration has a positive correlation with that in blood, the hydrogel colloidal crystal integrated into contact lens possesses promising potential for noninvasive monitoring of glucose in tears. This paper presents a new glucose-responsive sensor, which consists a crystalline colloidal array (CCA) embedded in hydrogel matrix, attached onto a rigid gas permeable (RGP) contact lens. This novel sensing lens is able to selectively diffract visible light, whose wavelength shifts between 567 and 468 nm according to the alternation of the glucose concentration between 0 and 50 mM and its visible color change between reddish yellow, green, and blue. The detection limit of responsive glucose concentration can be reduced to 0.05 mM. Its combination with a contact lens endows it with excellent biocompatibility and portability, which shows great possibility for it to push the development of glucose-detecting devices into new era.
Collapse
Affiliation(s)
- Jia-Li Ruan
- Department of Ophthalmology, EENT Hospital of Fudan University, Shanghai 200031, China.
| | - Cheng Chen
- School of Environmental and Materials Engineering, College of Engineering, Shanghai Polytechnic University, Shanghai 201209, China.
| | - Jian-Hua Shen
- Key Laboratory for Ultrafine Materials of Ministry of Education, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai 200237, China.
| | - Xue-Ling Zhao
- School of Environmental and Materials Engineering, College of Engineering, Shanghai Polytechnic University, Shanghai 201209, China.
| | - Shao-Hong Qian
- Department of Ophthalmology, EENT Hospital of Fudan University, Shanghai 200031, China.
| | - Zhi-Gang Zhu
- School of Environmental and Materials Engineering, College of Engineering, Shanghai Polytechnic University, Shanghai 201209, China.
| |
Collapse
|
31
|
Dutkiewicz EP, Urban PL. Quantitative mass spectrometry of unconventional human biological matrices. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2016; 374:20150380. [PMID: 27644966 PMCID: PMC5031645 DOI: 10.1098/rsta.2015.0380] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 06/02/2016] [Indexed: 06/06/2023]
Abstract
The development of sensitive and versatile mass spectrometric methodology has fuelled interest in the analysis of metabolites and drugs in unconventional biological specimens. Here, we discuss the analysis of eight human matrices-hair, nail, breath, saliva, tears, meibum, nasal mucus and skin excretions (including sweat)-by mass spectrometry (MS). The use of such specimens brings a number of advantages, the most important being non-invasive sampling, the limited risk of adulteration and the ability to obtain information that complements blood and urine tests. The most often studied matrices are hair, breath and saliva. This review primarily focuses on endogenous (e.g. potential biomarkers, hormones) and exogenous (e.g. drugs, environmental contaminants) small molecules. The majority of analytical methods used chromatographic separation prior to MS; however, such a hyphenated methodology greatly limits analytical throughput. On the other hand, the mass spectrometric methods that exclude chromatographic separation are fast but suffer from matrix interferences. To enable development of quantitative assays for unconventional matrices, it is desirable to standardize the protocols for the analysis of each specimen and create appropriate certified reference materials. Overcoming these challenges will make analysis of unconventional human biological matrices more common in a clinical setting.This article is part of the themed issue 'Quantitative mass spectrometry'.
Collapse
Affiliation(s)
- Ewelina P Dutkiewicz
- Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd, Hsinchu 300, Taiwan
| | - Pawel L Urban
- Department of Applied Chemistry, National Chiao Tung University, 1001 University Rd, Hsinchu 300, Taiwan Institute of Molecular Science, National Chiao Tung University, 1001 University Rd, Hsinchu 300, Taiwan
| |
Collapse
|
32
|
Nagy G, Peng T, Pohl NLB. General Label-Free Mass Spectrometry-Based Assay To Identify Glycosidase Substrate Competence. Anal Chem 2016; 88:7183-90. [DOI: 10.1021/acs.analchem.6b01360] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Gabe Nagy
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405, United States
| | - Tianyuan Peng
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405, United States
| | - Nicola L. B. Pohl
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405, United States
| |
Collapse
|
33
|
Gabriel EFM, Garcia PT, Cardoso TMG, Lopes FM, Martins FT, Coltro WKT. Highly sensitive colorimetric detection of glucose and uric acid in biological fluids using chitosan-modified paper microfluidic devices. Analyst 2016; 141:4749-56. [PMID: 27272206 DOI: 10.1039/c6an00430j] [Citation(s) in RCA: 112] [Impact Index Per Article: 12.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
This paper describes the modification of microfluidic paper-based analytical devices (μPADs) with chitosan to improve the analytical performance of colorimetric measurements associated with enzymatic bioassays. Chitosan is a natural biopolymer extensively used to modify biosensing surfaces due to its capability of providing a suitable microenvironment for the direct electron transfer between an enzyme and a reactive surface. This hypothesis was investigated using glucose and uric acid (UA) colorimetric assays as model systems. The best colorimetric sensitivity for glucose and UA was achieved using a chromogenic solution composed of 4-aminoantipyrine and sodium 3,5-dichloro-2-hydroxy-benzenesulfonate (4-AAP/DHBS), which provided a linear response for a concentration range between 0.1 and 1.0 mM. Glucose and UA were successfully determined in artificial serum samples with accuracies between 87 and 114%. The limits of detection (LODs) found for glucose and UA assays were 23 and 37 μM, respectively. The enhanced analytical performance of chitosan-modified μPADs allowed the colorimetric detection of glucose in tear samples from four nondiabetic patients. The achieved concentration levels ranged from 130 to 380 μM. The modified μPADs offered analytical reliability and accuracy as well as no statistical difference from the values achieved through a reference method. Based on the presented results, the proposed μPAD can be a powerful alternative tool for non-invasive glucose analysis.
Collapse
Affiliation(s)
- Ellen F M Gabriel
- Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil.
| | | | | | | | | | | |
Collapse
|
34
|
Coelho M, Mendes VM, Lima IS, Martins FO, Fernandes AB, Macedo MP, Jones JG, Manadas B. Direct analysis of [6,6-(2)H2]glucose and [U-(13)C6]glucose dry blood spot enrichments by LC-MS/MS. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1022:242-248. [PMID: 27107853 DOI: 10.1016/j.jchromb.2016.04.027] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2016] [Revised: 04/08/2016] [Accepted: 04/11/2016] [Indexed: 11/29/2022]
Abstract
A liquid chromatography tandem mass spectrometry (LC-MS/MS) using multiple reaction monitoring (MRM) in a triple-quadrupole scan mode was developed and comprehensively validated for the determination of [6,6-(2)H2]glucose and [U-(13)C6]glucose enrichments from dried blood spots (DBS) without prior derivatization. The method is demonstrated with dried blood spots obtained from rats administered with a primed-constant infusion of [U-(13)C6]glucose and an oral glucose load enriched with [6,6-(2)H2]glucose. The sensitivity is sufficient for analysis of the equivalent to <5μL of blood and the overall method was accurate and precise for the determination of DBS isotopic enrichments.
Collapse
Affiliation(s)
- Margarida Coelho
- CNC - Center for Neuroscience and Cell Biology, University of Coimbra, UC Biotech, Parque Tecnológico de Cantanhede, Núcleo 04, Lote 8, 3060-197 Cantanhede, Portugal
| | - Vera M Mendes
- CNC - Center for Neuroscience and Cell Biology, University of Coimbra, UC Biotech, Parque Tecnológico de Cantanhede, Núcleo 04, Lote 8, 3060-197 Cantanhede, Portugal
| | - Inês S Lima
- Chronic Diseases Research Center (CEDOC), NOVA Medical School/Faculdade de Ciências Médicas, Universidade Nova de Lisboa, Rua Câmara Pestana n° 6, 6-A Edifício CEDOC II, 1150-082 Lisboa, Portugal
| | - Fátima O Martins
- CNC - Center for Neuroscience and Cell Biology, University of Coimbra, UC Biotech, Parque Tecnológico de Cantanhede, Núcleo 04, Lote 8, 3060-197 Cantanhede, Portugal; Chronic Diseases Research Center (CEDOC), NOVA Medical School/Faculdade de Ciências Médicas, Universidade Nova de Lisboa, Rua Câmara Pestana n° 6, 6-A Edifício CEDOC II, 1150-082 Lisboa, Portugal; Institute for Interdisciplinary Research (IIIUC), University of Coimbra, Casa Costa Alemão, Pólo II, Rua Dom Francisco de Lemos, 3030-789 Coimbra, Portugal
| | - Ana B Fernandes
- Chronic Diseases Research Center (CEDOC), NOVA Medical School/Faculdade de Ciências Médicas, Universidade Nova de Lisboa, Rua Câmara Pestana n° 6, 6-A Edifício CEDOC II, 1150-082 Lisboa, Portugal
| | - M Paula Macedo
- Chronic Diseases Research Center (CEDOC), NOVA Medical School/Faculdade de Ciências Médicas, Universidade Nova de Lisboa, Rua Câmara Pestana n° 6, 6-A Edifício CEDOC II, 1150-082 Lisboa, Portugal; APDP-Portuguese Diabetes Association, Rua Rodrigo da Fonseca, n° 1, 1250-189 Lisboa, Portugal
| | - John G Jones
- CNC - Center for Neuroscience and Cell Biology, University of Coimbra, UC Biotech, Parque Tecnológico de Cantanhede, Núcleo 04, Lote 8, 3060-197 Cantanhede, Portugal; APDP-Portuguese Diabetes Association, Rua Rodrigo da Fonseca, n° 1, 1250-189 Lisboa, Portugal
| | - Bruno Manadas
- CNC - Center for Neuroscience and Cell Biology, University of Coimbra, UC Biotech, Parque Tecnológico de Cantanhede, Núcleo 04, Lote 8, 3060-197 Cantanhede, Portugal.
| |
Collapse
|
35
|
González-Arribas E, Pankratov D, Gounel S, Mano N, Blum Z, Shleev S. Transparent and Capacitive Bioanode Based on Specifically Engineered Glucose Oxidase. ELECTROANAL 2016. [DOI: 10.1002/elan.201600096] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
36
|
Muñoz-Hernández AM, Galbis-Estrada C, Santos-Bueso E, Cuiña-Sardiña R, Díaz-Valle D, Gegúndez-Fernández JA, Pinazo-Durán MD, Benítez-del-Castillo JM. Human tear metabolome. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2016; 91:157-159. [PMID: 26560163 DOI: 10.1016/j.oftal.2015.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2015] [Accepted: 09/15/2015] [Indexed: 06/05/2023]
Affiliation(s)
- A M Muñoz-Hernández
- Unidad de Superficie e Inflamación Ocular, Servicio de Oftalmología, Instituto de Investigación Sanitaria del Hospital Clínico Universitario San Carlos (IdISSC), Madrid, España.
| | - C Galbis-Estrada
- Unidad de Investigación Oftalmológica Santiago Grisolía, Valencia, España; Unidad de Investigación Oftalmológica, Facultad de Medicina, Universidad de Valencia, Valencia, España
| | - E Santos-Bueso
- Unidad de Neurooftalmología, Hospital Clínico Universitario San Carlos, Madrid, España
| | - R Cuiña-Sardiña
- Unidad de Superficie e Inflamación Ocular, Servicio de Oftalmología, Instituto de Investigación Sanitaria del Hospital Clínico Universitario San Carlos (IdISSC), Madrid, España; Red Española de Patología Ocular (OFTARED), España
| | - D Díaz-Valle
- Unidad de Superficie e Inflamación Ocular, Servicio de Oftalmología, Instituto de Investigación Sanitaria del Hospital Clínico Universitario San Carlos (IdISSC), Madrid, España; Red Española de Patología Ocular (OFTARED), España
| | - J A Gegúndez-Fernández
- Unidad de Superficie e Inflamación Ocular, Servicio de Oftalmología, Instituto de Investigación Sanitaria del Hospital Clínico Universitario San Carlos (IdISSC), Madrid, España; Red Española de Patología Ocular (OFTARED), España
| | - M D Pinazo-Durán
- Unidad de Investigación Oftalmológica Santiago Grisolía, Valencia, España; Unidad de Investigación Oftalmológica, Facultad de Medicina, Universidad de Valencia, Valencia, España; Red Española de Patología Ocular (OFTARED), España
| | - J M Benítez-del-Castillo
- Unidad de Superficie e Inflamación Ocular, Servicio de Oftalmología, Instituto de Investigación Sanitaria del Hospital Clínico Universitario San Carlos (IdISSC), Madrid, España; Red Española de Patología Ocular (OFTARED), España
| |
Collapse
|
37
|
|
38
|
Tsao CW, Yang ZJ. High Sensitivity and High Detection Specificity of Gold-Nanoparticle-Grafted Nanostructured Silicon Mass Spectrometry for Glucose Analysis. ACS APPLIED MATERIALS & INTERFACES 2015; 7:22630-22637. [PMID: 26393877 DOI: 10.1021/acsami.5b07395] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Desorption/ionization on silicon (DIOS) is a high-performance matrix-free mass spectrometry (MS) analysis method that involves using silicon nanostructures as a matrix for MS desorption/ionization. In this study, gold nanoparticles grafted onto a nanostructured silicon (AuNPs-nSi) surface were demonstrated as a DIOS-MS analysis approach with high sensitivity and high detection specificity for glucose detection. A glucose sample deposited on the AuNPs-nSi surface was directly catalyzed to negatively charged gluconic acid molecules on a single AuNPs-nSi chip for MS analysis. The AuNPs-nSi surface was fabricated using two electroless deposition steps and one electroless etching step. The effects of the electroless fabrication parameters on the glucose detection efficiency were evaluated. Practical application of AuNPs-nSi MS glucose analysis in urine samples was also demonstrated in this study.
Collapse
Affiliation(s)
- Chia-Wen Tsao
- Department of Mechanical Engineering, National Central University , Taoyuan City 32001, Taiwan
| | - Zhi-Jie Yang
- Department of Mechanical Engineering, National Central University , Taoyuan City 32001, Taiwan
| |
Collapse
|
39
|
Matsunami RK, Angelides K, Engler DA. Development and Validation of a Rapid (13)C6-Glucose Isotope Dilution UPLC-MRM Mass Spectrometry Method for Use in Determining System Accuracy and Performance of Blood Glucose Monitoring Devices. J Diabetes Sci Technol 2015; 9:1051-60. [PMID: 25986627 PMCID: PMC4667352 DOI: 10.1177/1932296815586015] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND There is currently considerable discussion about the accuracy of blood glucose concentrations determined by personal blood glucose monitoring systems (BGMS). To date, the FDA has allowed new BGMS to demonstrate accuracy in reference to other glucose measurement systems that use the same or similar enzymatic-based methods to determine glucose concentration. These types of reference measurement procedures are only comparative in nature and are subject to the same potential sources of error in measurement and system perturbations as the device under evaluation. It would be ideal to have a completely orthogonal primary method that could serve as a true standard reference measurement procedure for establishing the accuracy of new BGMS. METHODS An isotope-dilution liquid chromatography/mass spectrometry (ID-UPLC-MRM) assay was developed using (13)C6-glucose as a stable isotope analogue to specifically measure glucose concentration in human plasma, and validated for use against NIST standard reference materials, and against fresh isolates of whole blood and plasma into which exogenous glucose had been spiked. Assay performance was quantified to NIST-traceable dry weight measures for both glucose and (13)C6-glucose. RESULTS The newly developed assay method was shown to be rapid, highly specific, sensitive, accurate, and precise for measuring plasma glucose levels. The assay displayed sufficient dynamic range and linearity to measure across the range of both normal and diabetic blood glucose levels. Assay performance was measured to within the same uncertainty levels (<1%) as the NIST definitive method for glucose measurement in human serum. CONCLUSIONS The newly developed ID UPLC-MRM assay can serve as a validated reference measurement procedure to which new BGMS can be assessed for glucose measurement performance.
Collapse
Affiliation(s)
- Risë K Matsunami
- Proteomics Programmatic Core Laboratory, Houston Methodist Hospital Research Institute, Houston, TX, USA
| | | | - David A Engler
- Proteomics Programmatic Core Laboratory, Houston Methodist Hospital Research Institute, Houston, TX, USA
| |
Collapse
|
40
|
Galbis-Estrada C, Pinazo-Durán MD, Martínez-Castillo S, Morales JM, Monleón D, Zanon-Moreno V. A metabolomic approach to dry eye disorders. The role of oral supplements with antioxidants and omega 3 fatty acids. Mol Vis 2015; 21:555-67. [PMID: 25999682 PMCID: PMC4431415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2014] [Accepted: 05/08/2015] [Indexed: 11/10/2022] Open
Abstract
PURPOSE We used nuclear magnetic resonance spectroscopy of hydrogen-1 nuclei ((1)H NMR S) to analyze the metabolic profile of reflex tears from patients with dry eye disorders. METHODS We performed a prospective case-control study involving 90 participants: 55 patients diagnosed with dry eye syndrome (DESG) and 35 healthy subjects (control group, CG). From the DESG, two subgroups were formed: mild DES (n=22) and moderate DES (n=33). Participants were prescribed an oral nutraceutic supplementation containing antioxidants and essential polyunsaturated fatty acids to be taken as three capsules per day for 3 months. Reflex tears (20-30 µl) were collected from the tear meniscus of both eyes of each subject with a microglass pipette. Nuclear magnetic resonance (NMR) spectra were acquired with a standard one-dimensional pulse sequence with water suppression; 256 free induction decays were collected into 64,000 data points with 14 ppm spectral width. RESULTS Basal tears showed a differential metabolomic profile between groups. Almost 50 metabolites were identified by H cholesterol, N-acetylglucosamine, glutamate, amino-n-butyrate, choline, glucose, and formate were detected before supplementation and choline/acetylcholine after supplementation. The metabolic profile of the tears was statistically different between groups, as well as before and after supplementation. CONCLUSIONS Our data indicate that DES induces changes in the tear metabolic profile that can be modified with appropriate oral supplementation with antioxidants and essential polyunsaturated fatty acids.
Collapse
Affiliation(s)
- Carmen Galbis-Estrada
- Ophthalmic Research Unit “Santiago grisolía,” Valencia, Spain,Ophthalmic Research Unit, Faculty of Medicine, University of Valencia, Spain
| | - Maria Dolores Pinazo-Durán
- Ophthalmic Research Unit “Santiago grisolía,” Valencia, Spain,Ophthalmic Research Unit, Faculty of Medicine, University of Valencia, Spain,Spanish Collaborative Network of Ocular Pathology (OFTARED)
| | | | - José M. Morales
- Central Unit of Research in Medicine, University of Valencia, Valencia, Spain
| | - Daniel Monleón
- Fundacion Investigacion Hospital Clinico Universitario/INCLIVA, Valencia, Spain
| | - Vicente Zanon-Moreno
- Ophthalmic Research Unit “Santiago grisolía,” Valencia, Spain,Ophthalmic Research Unit, Faculty of Medicine, University of Valencia, Spain,Department of Preventive Medicine and CIBER Fisiopatología de la Obesidad y Nutrición, School of Medicine, University of Valencia, Spain
| |
Collapse
|
41
|
Farandos NM, Yetisen AK, Monteiro MJ, Lowe CR, Yun SH. Contact lens sensors in ocular diagnostics. Adv Healthc Mater 2015; 4:792-810. [PMID: 25400274 DOI: 10.1002/adhm.201400504] [Citation(s) in RCA: 230] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2014] [Revised: 09/23/2014] [Indexed: 01/15/2023]
Abstract
Contact lenses as a minimally invasive platform for diagnostics and drug delivery have emerged in recent years. Contact lens sensors have been developed for analyzing the glucose composition of tears as a surrogate for blood glucose monitoring and for the diagnosis of glaucoma by measuring intraocular pressure. However, the eye offers a wider diagnostic potential as a sensing site and therefore contact lens sensors have the potential to improve the diagnosis and treatment of many diseases and conditions. With advances in polymer synthesis, electronics and micro/nanofabrication, contact lens sensors can be produced to quantify the concentrations of many biomolecules in ocular fluids. Non- or minimally invasive contact lens sensors can be used directly in a clinical or point-of-care setting to monitor a disease state continuously. This article reviews the state-of-the-art in contact lens sensor fabrication, their detection, wireless powering, and readout mechanisms, and integration with mobile devices and smartphones. High-volume manufacturing considerations of contact lenses are also covered and a case study of an intraocular pressure contact lens sensor is provided as an example of a successful product. This Review further analyzes the contact lens market and the FDA regulatory requirements for commercialization of contact lens sensors.
Collapse
Affiliation(s)
- Nicholas M. Farandos
- Department of Chemical Engineering; Imperial College London; South Kensington Campus London SW7 2AZ UK
| | - Ali K. Yetisen
- Department of Chemical Engineering and Biotechnology; University of Cambridge; Tennis Court Road Cambridge CB2 1QT UK
| | - Michael J. Monteiro
- Australian Institute for Bioengineering and Nanotechnology; University of Queensland; Brisbane QLD 4072 Australia
| | - Christopher R. Lowe
- Department of Chemical Engineering and Biotechnology; University of Cambridge; Tennis Court Road Cambridge CB2 1QT UK
| | - Seok Hyun Yun
- Harvard Medical School and Wellman Center for Photomedicine; Massachusetts General Hospital; 50 Blossom Street Boston MA 02114 USA
| |
Collapse
|
42
|
Kim HJ, Jeong S, Noh H. Quantitative Determination of Tear Glucose Using Paper Based Microfluidic Devices. JOURNAL OF THE KOREAN CHEMICAL SOCIETY-DAEHAN HWAHAK HOE JEE 2015. [DOI: 10.5012/jkcs.2015.59.1.88] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
43
|
Cha KH, Qin Y, Meyerhoff ME. Origin of Low Detection Limit and High Selectivity of Roche Accu-Chek Test Strips that Enables Measurement of Tear Glucose Levels. ELECTROANAL 2015. [DOI: 10.1002/elan.201400576] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
44
|
Blum Z, Pankratov D, Shleev S. Powering electronic contact lenses: current achievements, challenges, and perspectives. EXPERT REVIEW OF OPHTHALMOLOGY 2014. [DOI: 10.1586/17469899.2014.922873] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
45
|
Differential effects of dry eye disorders on metabolomic profile by 1H nuclear magnetic resonance spectroscopy. BIOMED RESEARCH INTERNATIONAL 2014; 2014:542549. [PMID: 24967377 PMCID: PMC4055474 DOI: 10.1155/2014/542549] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Revised: 04/16/2014] [Accepted: 04/29/2014] [Indexed: 11/25/2022]
Abstract
We used 1H NMR spectroscopy to analyze the metabolomic profile of reflex tears from patients with dry eye disorders (DEDs). 90 subjects were divided into 2 groups: (1) patients with DEDs (DEDG; n = 55) and (2) healthy subjects (CG; n = 35). Additionally, the DEDG was subdivided into 2 subgroups based on DED severity: mild-to-moderate and moderate (n = 22 and n = 33, resp.). Personal interviews and systematized ophthalmologic examinations were carried out. Reflex tears (20–30 μL) were collected by gently rubbing in the inferior meniscus of both eyelids with a microglass pipette and stored at −80°C until analysis. NMR spectra were acquired using a standard one-dimensional pulse sequence with water suppression. Data were processed and transferred to MATLAB for further chemometric analysis. Main differences in tear composition between DEDG and CG were found in cholesterol, N-acetylglucosamine, glutamate, creatine, amino-n-butyrate, choline, acetylcholine, arginine, phosphoethanolamine, glucose, and phenylalanine levels. This metabolic fingerprint helped also to discriminate between the three additional subgroups of DEDG. Our results suggest that tear metabolic differences between DEDG and CG identified by NMR could be useful in understanding ocular surface pathogenesis and improving biotherapy.
Collapse
|
46
|
A gold@silica core–shell nanoparticle-based surface-enhanced Raman scattering biosensor for label-free glucose detection. Anal Chim Acta 2014; 811:76-80. [DOI: 10.1016/j.aca.2013.12.009] [Citation(s) in RCA: 75] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2013] [Revised: 12/02/2013] [Accepted: 12/04/2013] [Indexed: 02/08/2023]
|
47
|
Monge ME, Pérez JJ, Dwivedi P, Zhou M, McCarty NA, Stecenko AA, Fernández FM. Ion mobility and liquid chromatography/mass spectrometry strategies for exhaled breath condensate glucose quantitation in cystic fibrosis studies. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2013; 27:2263-2271. [PMID: 24019192 DOI: 10.1002/rcm.6683] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2013] [Revised: 07/08/2013] [Accepted: 07/09/2013] [Indexed: 06/02/2023]
Abstract
RATIONALE Cystic fibrosis related diabetes (CFRD) is an important complication of cystic fibrosis (CF) because it causes acceleration in the decline in lung function. Monitoring concentrations of key metabolites such as glucose in airway lining fluid is necessary for improving our understanding of the biochemical mechanisms linking diabetes and CF. Targeted-metabolomic strategies for glucose quantitation in exhaled breath condensate (EBC) from healthy individuals are presented. METHODS Three different electrospray ionization mass spectrometry (ESI-MS)-based methods were developed for EBC sample interrogation and glucose quantitation without derivatization. Two methods utilized ultra-high-performance liquid chromatography (UHPLC) coupled to either time-of-flight (TOF) MS or triple quadrupole (QqQ) tandem MS (MS/MS). A third approach involved direct-infusion traveling wave ion mobility spectrometry (TWIMS) with TOF-MS detection. UHPLC/QqQ-MS/MS was used for urea quantitation as the EBC dilution marker. Matrix effects were mitigated using isotopically labeled glucose and urea as internal standards. RESULTS All the developed methods allowed glucose and urea quantitation in EBC with high accuracy and precision. The UHPLC/TOF-MS and UHPLC/QqQ-MS/MS methods provided similar analytical figures of merit. UHPLC/QqQ-MS/MS provided the highest sensitivity and the lowest limit of detection (LOD) of 1.5 nM in EBC for both glucose and urea. The TWIMS-TOF-MS-based method provided the highest sample throughput capability; however, the glucose LOD was ~3-fold higher than with the two chromatographic methods. CONCLUSIONS Mass spectrometric methods for the quantitative analysis of trace EBC glucose levels are reported and compared for the first time. The analytical figures of merit demonstrate the applicability of these methods to metabolite analysis of airway samples for CF and CFRD research.
Collapse
Affiliation(s)
- María Eugenia Monge
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, GA, 30332, USA
| | | | | | | | | | | | | |
Collapse
|
48
|
Lee HS, Lee JM, Park SR, Lee JH, Kim YG. Development and Validation of Primary Method for the Determination of Glucose in Human Serum by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry and Comparison with Field Methods. B KOREAN CHEM SOC 2013. [DOI: 10.5012/bkcs.2013.34.6.1698] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
49
|
Falk M, Andoralov V, Silow M, Toscano MD, Shleev S. Miniature biofuel cell as a potential power source for glucose-sensing contact lenses. Anal Chem 2013; 85:6342-8. [PMID: 23735164 DOI: 10.1021/ac4006793] [Citation(s) in RCA: 92] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A microscale membrane-less biofuel cell, capable of generating electrical energy from human lachrymal liquid, was developed by utilizing the ascorbate and oxygen naturally present in tears as fuel and oxidant. The biodevice is based on three-dimensional nanostructured gold electrodes covered with abiotic (conductive organic complex) and biological (redox enzyme) materials functioning as efficient anodic and cathodic catalysts, respectively. Three-dimensional nanostructured electrodes were fabricated by modifying 100 μm gold wires with 17 nm gold nanoparticles, which were further modified with tetrathiafulvalene-tetracyanoquinodimethane conducting complex to create the anode and with Myrothecium verrucaria bilirubin oxidase to create the biocathode. When operated in human tears, the biodevice exhibited the following characteristics: an open circuit voltage of 0.54 V, a maximal power density of 3.1 μW cm(-2) at 0.25 V and 0.72 μW cm(-2) at 0.4 V, with a stable current density output of over 0.55 μA cm(-2) at 0.4 V for 6 h of continuous operation. These findings support our proposition that an ascorbate/oxygen biofuel cell could be a suitable power source for glucose-sensing contact lenses to be used for continuous health monitoring by diabetes patients.
Collapse
Affiliation(s)
- Magnus Falk
- Biomedical Sciences, Health & Society, Malmö University, 205 06 Malmö, Sweden
| | | | | | | | | |
Collapse
|
50
|
Hu Y, Jiang X, Zhang L, Fan J, Wu W. Construction of near-infrared photonic crystal glucose-sensing materials for ratiometric sensing of glucose in tears. Biosens Bioelectron 2013; 48:94-9. [PMID: 23651573 DOI: 10.1016/j.bios.2013.03.082] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2013] [Revised: 03/15/2013] [Accepted: 03/26/2013] [Indexed: 11/26/2022]
Abstract
Noninvasive monitoring of glucose in tears is highly desirable in tight glucose control. The polymerized crystalline colloidal array (PCCA) that can be incorporated into contact lens represents one of the most promising materials for noninvasive monitoring of glucose in tears. However, low sensitivity and slow time response of the PCCA reported in previous arts has limited its clinical utility. This paper presents a new PCCA, denoted as NIR-PCCA, comprising a CCA of glucose-responsive sub-micrometered poly(styrene-co-acrylamide-co-3-acrylamidophenylboronic acid) microgels embedded within a slightly positive charged hydrogel matrix of poly(acrylamide-co-2-(dimethylamino)ethyl acrylate). This newly designed NIR-PCCA can reflect near-infrared (NIR) light, whose intensity (at 1722 nm) would decrease evidently with increasing glucose concentration over the physiologically relevant range in tears. The lowest glucose concentration reliably detectable was as low as ca. 6.1 μg/dL. The characteristic response time τ(sensing) was 22.1±0.2s when adding glucose to 7.5 mg/dL, and the higher the glucose concentration is, the faster the time response. Such a rationally designed NIR-PCCA is well suited for ratiometric NIR sensing of tear glucose under physiological conditions, thereby likely to bring this promising glucose-sensing material to the forefront of analytical devices for diabetes.
Collapse
Affiliation(s)
- Yumei Hu
- State Key Laboratory for Physical Chemistry of Solid Surfaces, The Key Laboratory for Chemical Biology of Fujian Province, and Department of Chemistry, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | | | | | | | | |
Collapse
|